HomeMy WebLinkAbout43C-2016121INSPFACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 1 of 4
UNIT TYPE:
Lined MSWLF LCID X YW Transfer Compost SLAS COUNTY: HARNETT
Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: 43C-LCID-
CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE
Date of Site Inspection: January 21, 2016 Date of Last Inspection: August 11, 2011
FACILITY NAME AND ADDRESS:
Blaylock Grading LCID Landfill 1025 Claude White Road
Sanford, North Carolina 27332
GPS COORDINATES: N: 35.31257 E: -79.16078
FACILITY CONTACT NAME AND PHONE NUMBER: Harold Blaylock, President, Blaylock Grading LLP
910-818-8398 David Stephens, Landfill Attendant
FACILITY CONTACT ADDRESS: Blaylock Grading LLP
345 Caulton Brown Road
Lillington, North Carolina 27546-7826
PARTICIPANTS:
Liz Patterson – NCDEQ, Solid Waste Section Drew Hammonds – NCDEQ, Solid Waste Section
David Stephens – Blaylock Grading LLP
STATUS OF PERMIT:
Original Permit to Construct (PTC) Phase I issued July 13, 2000
Original Permit to Operate (PTO) issued October16, 2000
Permit Modification PTC Phase I Revision issued July 27, 2003 Permit Renewal PTC/PTO Phases 1 through 4 issued April 8, 2010
Permit Renewal PTO Phases 2 through 4 issued July 26, 2013
PTO expires July 26, 2018
PURPOSE OF SITE VISIT: Comprehensive Inspection
STATUS OF PAST NOTED VIOLATIONS: NONE
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 2 of 2
OBSERVED VIOLATIONS:
Per 15A NCAC 13B .0566(2), “The facility shall only accept those solid wastes which it is permitted to receive.”
Unaceptable waste streams were noted during the inspection. Pallets, scrap metal, tires, and any other
unacceptable waste need to be removed and taken for proper disposal. Black “sand” or Filter material from
Water Treatment Plant has not been approved for acceptance at facility according to current permit.
ADDITIONAL COMMENTS
On January 21, 2016, Liz Patterson and Drew Hammonds met with David Stephens to conduct a comprehensive inspection of the Blaylock Grading LCID Landfill located at 10255 Claude White Road, Harnett County.
1. The facility is a land clearing and inert debris (LCID) landfill. 2. The facility has proper signage. 3. The PTO expiration date is July 26, 2018. The permit renewal application due date is December 26, 2017.
4. The facility is properly secured with a locked gate. Personnel are on site during operating hours. 5. The facility has proper signage.
6. The facility is permitted to receive waste generated within Harnett County, Southern Lee County, and Eastern Moore
County. 7. The facility is permitted to receive land clearing waste, yard trash, untreated and unpainted wood,
uncontaminated soil, inert debris, and asphalt.
8. The facility site plan, operations plan, and permit are not kept on site and were not reviewed with the site attendant at this inspection. Please have a copy of the facility site plan, operations plan, and permit onsite for future inspections.
9. Per 15A NCAC 13B .0566(3), “Solid waste shall be restricted to the smallest area feasible and compacted as
densely as practical into cells.”
10. Ensure the LCD disposal area is graded accordingly, to include a defined working face and soil cover.
Excavation, grading and fill material side slopes shall not exceed three to one (3:1).
11. Per 15A NCAC 13B .0566(4), “Adequate soil cover shall be applied monthly, or when the active area reaches
one acre in size, whichever occurs first.” Based on observations of the site at the time of this inspection, it
appears that uncovered waste was exceeding one acre and had not been covered as required by rule. According
to #7 of the approved operations plan, the operator will keep the LCID working face as small as possible with a
½ acre maximum size. All areas of waste that are not part of the working face must be covered within 30 days.
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 3 of 3
12. A ready supply of soil shall be available for cover material.
13. Ponding of water observed on top of landfill. Grade top of landfill to ensure positive drainage of surface water off the
landfill. 14. Solid waste shall not be disposed of in water. It appeared that waste was being pushed into a surface water feature
located along the west side of the landfill in the tree line.
15. Permanent waste boundary markers need to be installed within 30 days and maintained around the entire
landfill to include active and inactive areas. Waste marker frequency should be placed so that you can see from
one to the other.
16. Property lines must be marked within 30 days to ensure that waste is not being dumped into the 100’ buffer for
this facility.
17. Stockpiled materials are being maintained in reasonably sized piles with adequate fire breaks. 18. Access roads are of all-weather construction.
19. Digital pictures were taken during the inspection.
20. Corrective measures are necessary at this facility. Measures to bring the facility into compliance must be completed within 30 days receipt of this report. The SWS will conduct a follow-up inspection in 30 days to ensure issues noted in
this inspection report have been addressed
Please contact me if you have any questions or concerns regarding this inspection report.
Phone: 919-707-8286(O) 919-805-6499(C)
elizabeth.patterson@ncdenr.gov
Liz Patterson Environmental Senior Specialist
Regional Representative
Sent on: Email Hand delivery X US Mail Certified No. [ _]
Copies: Jason Watkins, Field Operations Branch Head Supervisor - Solid Waste Section Drew Hammonds, Environmental Senior Specialist – Solid Waste Section
Jessica Montie, Compliance Officer – Solid Waste Section
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Page 4 of 4
Digital pictures taken by Liz Patterson on January 21, 2016
Facility sign at entrance Top of landfill – working face
WTP filter sand/carbon - unapproved waste Ponding water on top of landfill
Back side of landfill from road Stockpiled inert debris