Loading...
HomeMy WebLinkAbout7202T_INSP_20170216FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined MSWLF LCID X YW X Transfer X Compost SLAS COUNTY: Perquimans Closed MSWLF HHW White goods X Incin T&P FIRM PERMIT NO.: 7202T-Transfer- 1995 CDLF Tire T&P / Collection X Tire Monofill Industrial Landfill DEMO SDTF FILE TYPE: COMPLIANCE Date of Site Inspection: February 16, 2017 Date of Last Inspection: April 27, 2016 FACILITY NAME AND ADDRESS: Perquimans-Chowan-Gates County Transfer Station 759 Perry's Bridge Road Belvidere, North Carolina, 27919 GPS COORDINATES: N: 36.30906 E: -76.54580 FACILITY CONTACT NAME AND PHONE NUMBER: Name: Brad Gardner Name: Stacey Bowen Telephone: 252-297-3300 Telephone: 252-943-3702 Telephone: 252-339-9616 Telephone: 252-945-3198 Email Address: bgardner@arhs-nc.org Email Address: sbowen@bowencompany.us FACILITY CONTACT ADDRESS: PCG Transfer Station, 759 Perry's Bridge Road Belvidere, North Carolina, 27919 PARTICIPANTS: Brad Gardner – ARHS John College - DWM STATUS OF PERMIT: Active - issued August 14, 2014. Expires - July 08, 2019 PURPOSE OF SITE VISIT: Comprehensive Facility Compliance Inspection STATUS OF PAST NOTED VIOLATIONS: None OBSERVED VIOLATIONS None The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 ADDITIONAL COMMENTS; 1 – Facility has signage posted at entrance and has all required information on signs. 2 – Road is of all-weather construction. 3 – Facility has locking gate for security. 4 – Operating hours are M-F 8am – 4pm. Closed on Saturday and Sunday. 5 – Facility is permitted to receive waste from Perquimans, Chowan and Gates Counties. 6 – Screening records were available for review and one load per day was documented. 7 – Records for incoming loads and weights are done at scales and copies were available for review at the transfer station. 8 – Contingency Plan posted in Breakroom. 9 – Facility has 3 fire extinguishers available for fire protection and were serviced in 2016. 10 – Yard Waste and Land Clearing & Inert Debris areas appear to be managed well. 11 – Facility has 3 Certified operators: David Lowe – expires 05/25/2019 – Mitch Spencer, Jr. – expires 05/25/2019 and Charlie Rome – expires 03/12/2019. 12 – Pesticide building is ¾ full. 13 – Electronics building is almost full and most items are bundled and wrapped for removal. 14 – Leachate tanks were pumped out on 09/30/2016. 15 – Tipping floor was clean and both exhaust fans have been replaced. Also, a push wall has been added along with partial new metal for the exterior of the building. 16 – Metal pile is growing fast. Need to keep the refrigerators/freezers upright until the refrigerate has been removed. Some were laying down which could potentially cause leakage. Mark the ones where the refrigerant has been removed. 17 – Tires are kept in open top trailers. 18 – Cow watering troughs have been purchased to put behind load out trailers to capture any leakage of leachate from trailers in the event of a bad seal. 19 – Windblown trash is picked up daily. 20 - Digital pictures were taken inside of the Transfer Station. Please contact me if you have any questions or concerns regarding this inspection report. ___________________________ Phone: 919-268-1524 Email: john.college@ncdenr.gov Environmental Senior Specialist Regional Representative Sent on: February 20, 2017 X Email Hand delivery US Mail Certified No. [ _] Copies: * Andrew Hammonds – Eastern District Supervisor * Jessica Montie – Compliance Officer FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 3 of 3