Loading...
HomeMy WebLinkAboutSDTF3604_INSP_20161027FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 2 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Gaston Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: SDTF-36-04 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF X FILE TYPE: COMPLIANCE Date of Site Inspection: October 27, 2016 Date of Last Inspection: June 9, 2016 FACILITY NAME AND ADDRESS: Stanley Environmental Solutions 351 Colt Thornburg Road Dallas, NC 28034 GPS COORDINATES: N: 35.36151° W: 81.16931° FACILITY CONTACT NAME AND PHONE NUMBER: Name: Jim Lanier Telephone: (704) 263-8186 Email address: jim@stanleyenviro.com FACILITY CONTACT ADDRESS: 131 Mariposa Road Stanley, NC 28164 PARTICIPANTS: Troy Harrison, Composting & Land Application Branch Connie Wylie, Composting & Land Application Branch Jim Lanier, Stanley Environmental Solutions STATUS OF PERMIT: Active Issued: 6/9/2015 Expires: 3/20/2017 PURPOSE OF SITE VISIT: Routine Inspection STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: N/A The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 ADDITIONAL COMMENTS 1. The permitted facility consists of five 20,000 gallon tanks, two 28,000 gallon tanks, two 10,000 gallon tanks and one 50,000 gallon tank for an approximate total capacity of 226,000 gallons for the storage of untreated and treated septage. The two 10,000 gallon tanks have been removed. The permit lists a future 30,000 gallon tank which shall not be utilized for septage detention until it has been placed in position and inspected by tis office. 2. “No Trespassing” signs were posted at the entrance to the facility. 3. No objectionable odors were observed outside of the facility. 4. It appeared that the setback requirements were being maintained. 5. The permitted tanks appeared to be structurally sound and no leaks were observed. 6. It appeared that facility operations were being carried out as detailed in the approved Permitting and Operations Manual for the facility. 7. No spills were observed on the ground outside of the building. Please contact me if you have any questions or concerns regarding this inspection report. _______________________________________ Phone: 828-296-4701 Troy Harrison Environmental Senior Specialist Regional Representative Sent on: 2/17/2017 X Email Hand delivery US Mail Certified No. [ _] Copies: Corinne Law, Composting & Land Application Branch Connie Wylie, Composting & Land Application Branch