Loading...
HomeMy WebLinkAbout18044_LRMF_EMP_20160506 S:\AAA-Master Projects\NC DOT Right-of-Way -ROW\ROW-500s\ROW-508 P-3800 CRISP BF Management\Revised EMP\EMP Cover Letter3.doc Via Email May 6, 2016 NC DEQ - Brownfields Program 1646 Mail Service Center Raleigh, NC 27699-1646 Attention: Ms. Carolyn Minnich Re: Revised Environmental Management Plan NC DOT Charlotte Locomotive and Railcar Maintenance Facility Charlotte, North Carolina Brownfields ID 18044-14-060 H&H Job No. ROW-508 Dear Carolyn: Please find the attached electronic version of the revised Brownfields Environmental Management Plan (EMP) for the above-referenced site. NC DOT 100% plans are included as an attachment to the EMP. If you have any questions or comments, please feel free to contact us. Sincerely, Hart & Hickman, PC David Graham Matt Bramblett, PE Senior Project Geologist Principal cc: Mr. Cyrus Parker, NC DOT (via email) Mr. Gordon Box, NC DOT (via email) Attachment NC Brownfields Environmental Management Plan Charlotte Locomotive and Railcar Maintenance Facility Charlotte, Mecklenburg County North Carolina H&H Job No. ROW-508 State Project P-3800 WBS Element #49999.1.STR8 May 6, 2016 1  EMP Form ver.1, October 23, 2014  NORTH CAROLINA BROWNFIELDS PROGRAM  ENVIRONMENTAL MANAGEMENT PLAN    This form is to be used to prepare an Environmental Management Plan (EMP) for projects in the  North Carolina Brownfields Program at the direction of a project manager for the program.   Prospective Developers and/or their consultants must complete and submit this form and all  pertinent attachments to their project manager prior to any site earthmoving or other  development related activities.  For the resultant EMP to be valid for use, it must be completed,  reviewed by the program, and signed by all signers at the bottom.  Consult your project  manager if you have questions.    GENERAL INFORMATION    Date:   5/6/2016    Brownfields Assigned Project Name:   Charlotte Locomotive and Railcar Maintenance Facility ‐ Charlotte  Railroad Improvement and Safety Program (CRISP)    Brownfields Project Number:  18044‐14‐060    Brownfields Property Address:  NC DOT Parcel 32 ‐ 1320 S. Graham St (PIN 07326216) and NC DOT  Parcel 31 ‐ southern portion (Parcel 31.1) of 1336 S. Graham St (PIN 07326215)    Brownfields Property Area (acres):  approximately 2.5 acres    Is Brownfields Property Subject to RCRA Permit?     ☐  Yes   ☒ No  If yes enter Permit No.: Click here to enter text.    Is Brownfields Property Subject to a Solid Waste Permit?  ☐ Yes  ☒ No   If yes, enter Permit No.:          COMMUNICATIONS    Prospective Developer (PD):  North Carolina Department of Transportation  Phone Numbers:    Office:  (919) 707‐4731…..Mobile:  NA  Email:  cmnewton@ncdot.gov  Primary PD Contact: Craig Newton, PE  Phone Numbers:  Office:  (919) 707‐4731   Mobile:  NA  Email:  Environmental Consultant:  Hart & Hickman, PC ‐ Matt Bramblett, PE    Phone Numbers:    Office:  (704) 887‐4620…..Mobile:  (704) 560‐8009  Email:  mbramblett@harthickman.com   Brownfields Program Project Manager: Carolyn Minnich  2  EMP Form ver.1, October 23, 2014   Office:  (704) 661‐0330   Email:   Carolyn.minnich@ncdenr.gov    Other DENR Program Contacts (if applicable, i.e., UST Section, Inactive Hazardous Site Branch,  Hazardous Waste, Solid Waste): NA        NOTIFICATIONS TO THE BROWNFIELDS PROGRAM    Advance Notification Times to Brownfields Project Manager:  Check each box to accept minimum  notice periods (in calendar days) for each type of onsite task:  On‐site assessment or remedial activities:     Within 10 days ☒   Construction or grading start:        Within 10 days  ☒  Discovery of stained soil, odors, USTs, buried drums or waste, landfill, or other signs of previously  unknown contamination:      Within 48 hours ☒   Implementation of emergency actions (e.g. dewatering, flood, or soil erosion control  measures in area of contamination, venting of explosive environments):   Within 48 hours  ☒  Installation of mitigation systems:       Within 10 days ☒  Other notifications as required by local, state or federal agencies to implement  redevelopment activities: (as applicable):      Within 30 days ☒        REDEVELOPMENT PLANS    1) Type of Redevelopment (check all that apply):     ☐ Residential   ☐ Recreational  ☐  Institutional  ☐ Commercial  ☐ Office   ☐Retail  ☒ Industrial    ☐  Other  specify: Click here to enter text.    2)  Summary of Redevelopment Plans (attach conceptual or detailed plans as available):   a) Do plans include demolition of structure(s)?:  ☒ Yes   ☐ No   ☐ Unknown  b)  Do plans include removal of building foundation slab(s) or pavement:    ☒  Yes  ☐ No   ☐ Unknown  c) Provide brief summary of redevelopment plans, including demolition, removal of building  slabs/pavement and other structures: Preliminary redevelopment plans included demolition  of the Ferguson Plumbing and Supply buildings on Parcel 32 (1320 S. Graham Street).  These  buildings have been demolished.  The building slab on the northern portion of the property  has been removed.  The building slab and asphalt parking located on the remaining southern  portion of the property will remain in place until a potential separate phase of the project is  conducted in the area (schedule unknown).  The southern portion of  1336 S. Graham Street  (Parcel 31.1)  is occupied by a driveway, asphalt parking area, and a concrete slab area that  will be removed prior to construction activities.  NC DOT plans to redevelop the subject  3  EMP Form ver.1, October 23, 2014  properties along with several other adjacent and nearby properties with a locomotive and  railcar maintenance facility.  Preliminary Site Layout and Construction Plans are included in  Appendix A.    3)  Which category of risk‐based screening level is used or is anticipated to be specified in the  Brownfields Agreement?  ☐ Residential    ☒ Non‐residential or Industrial/Commercial            Note: If children frequent the property, residential screening levels shall be cited in the Brownfields  Agreement for comparison purposes.     4)  Schedule for Redevelopment (attach construction schedule):  a) Phase I start date and anticipated duration (specify activities during each phase):                   7/1/2016  The Project Redevelopment schedule is provided for the overall project which includes the 2  Brownfields parcels as well as other parcels.   The Phase I project schedule prior to a 4 month  delay is included in Appendix B. The schedule should be viewed by adding 4 months to the dates  given.       b) If applicable, Phase 2 start date and anticipated duration (specify activities during each  phase): To be determined.              c) Additional phases planned?  If yes, specify activities if known:    ☐ Yes   ☐ No   ☒ Not in the foreseeable future   ☐Decision pending  d) Provide the planned date of occupancy for new buildings:  No buildings will be located on the  subject properties.    CONTAMINATED MEDIA  Contaminated Media (attach tabulated data summaries for each impacted media and figure(s) with  sample locations):  Part 1. Soil:       ☒ Yes   ☐ No    ☐  Suspected          Part 2. Groundwater:       ☐ Yes  ☒  No   ☐  Suspected          Part 3. Surface Water:    ☐ Yes  ☒  No   ☐  Suspected          Part 4.  Sediment:                          ☐ Yes   ☒ No    ☐ Suspected  Part 5. Soil Vapor:       ☐ Yes  ☐  No   ☒  Suspected          Part 6. Sub‐Slab Soil Vapor:         ☐  Yes ☐  No   ☒  Suspected          Part 7. Indoor Air:              ☐  Yes  ☐  No   ☒  Suspected           4  EMP Form ver.1, October 23, 2014  PART 1.  SOIL – Please fill out the information below, using detailed site plans, if available, or estimate  using  known areas of contaminated soil and a conceptual redevelopment plan. Provide a figure  overlaying new construction onto figure showing contaminated soil and groundwater locations.    1) Known or suspected contaminants in soil (list specific compounds):   The project area consists of a former junkyard (Parcel 32) and foundry warehouse and storage (Parcel 31). A summary of parcel information and soil and groundwater impacts identified in the project area are provided in Table 1. A Project Location Map and a Site Map depicting the project area are provided as Figures 1 and 2, respectively. A compilation map of impacted soil at any level is provided as Figure 3, and a compilation map of impacted soil above Industrial SRGs is provided as Figure 4. Preliminary construction and grading plans are included in Appendix A. Available data tables and figures depicting assessment data for each parcel are included in Appendix C.   2) Depth of known or suspected contaminants (feet):   See soil data tables and figures depicting the impacted soil areas for each parcel included in Appendix C.   3) Area of soil disturbed by redevelopment (square feet):   Approximately 15,200 sq ft  4) Depths of soil to be excavated (feet):  Up to 16 ft  5) Estimated volume of soil (cubic yards) to be excavated (attach grading plan):    Approximately  7,500 cy  6) Estimated volume of excavated soil (cubic yards) anticipated to be impacted by contaminants:       Approximately 1,600 cy  7) Estimated volume of contaminated soil expected to be disposed of offsite, if applicable: 550 cy  IMPORTED FILL SOIL    1) Will fill soil be imported to the site?     ☐  Yes   ☐  No   ☒ Unknown  2) If yes, what is the estimated volume of fill soil to be imported?  To be determined  3) If yes, what is the depth of fill soil to be used at the property?    To be determined  If a range of depths, please list the range.    4) PRIOR TO ITS PLACEMENT AT THE BROWNFIELDS PROPERTY, provide plan to analyze fill soil to  demonstrate that it meets acceptable standards and can be considered clean for use at the  Brownfields property (Check all that apply):     ☒   Volatile organic compounds (VOCs) by EPA Method 8260   ☒  Semi‐volatile organic compounds (SVOCs) by EPA Method 8270   ☐   Metals RCRA List (8) (arsenic, barium, cadmium, chromium (speciated), mercury, lead,  selenium and silver)   ☒  Metals –Hazardous Substance List ‐14 (antimony, arsenic, beryllium, cadmium, chromium  (speciated according to IHSB protocol), copper, lead, manganese, mercury, nickel, selenium, silver,  thallium, and zinc)   ☐ Metals – EPA Priority Pollutant List – 13 (arsenic, beryllium, cadmium, chromium (speciated  according to IHSB protocol), copper, mercury, nickel, lead, antimony, selenium, silver, thallium, and  zinc)   ☒ Other Constituents & Analytical Method:  PCBs (1668)   ☐ Known borrow material (DESCRIBE SOURCE AND ATTACH SAMPLING PROFILE):  To be  determined  5  EMP Form ver.1, October 23, 2014    MANAGING ONSITE SOIL     1) If soil in known or suspected areas of contamination is anticipated to be excavated from the  Brownfield Property, relocated on the Brownfields Property,or otherwise disturbed during site  grading or other redevelopment activities, please provide a grading plan that clearly illustrates  areas of cut and fill (approximate areas & volumes are acceptable, if only preliminary data  available).    2) HAZARDOUS WASTE DETERMINATION –  Does the soil contain a LISTED WASTE as defined in the  North Carolina Hazardous Waste Section under 40 CFR Part 261.31‐261.35? ☐ Yes     ☒  No        If yes, explain why below, including the level of knowledge regarding processes generating the  waste( include pertinent analytical results as needed).           If yes, do the soils exceed the “Contained‐Out” levels in Attachment 1 of the North Carolina  Contained‐In Policy? ☐ Yes     ☐  No        NOTE: IF SOIL MEETS THE DEFINITION OF A LISTED HAZARDOUS WASTE AND EXCEEDS THE  CONTAINED‐OUT LEVELS IN ATTACHMENT 1 TO THE NORTH CAROLINA CONTAINED‐IN POLICY THE  SOIL MAY NOT BE RE‐USED ON SITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DENR  HAZARDOUS WASTE SECTION RULES AND REGULATIONS.           3) HAZARDOUS WASTE DETERMINATION – Does the soil contain a CHARACTERISTIC WASTE?:    ☒ Yes     ☐  No      If yes, mark reason(s) why below (and include pertinent analytical results).        ☐ Ignitability    ☐ Corrosivity    ☐  Reactivity    ☐  Toxicity    ☒  TCLP results    ☐ Rule of 20 results (20 times total analytical results for an individual hazardous  constituent on TCLP list cannot, by test method, exceed regulatory TCLP standard)    If no, explain rationale:          NOTE: IF SOIL MEETS THE DEFINITION OF A CHARACTERISTIC HAZARDOUS WASTE, THE SOIL MAY NOT  BE RE‐USED ON SITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DENR HAZARDOUS WASTE  SECTION RULES AND REGULATIONS.    4) Screening criteria by which soil disposition decisions will be made (e.g., left in place, capped in  place with low permeability barrier, removed to onsite location and capped, removed offsite):   ☐  Preliminary Health‐Based Residential SRGs Click here to enter a date.   ☒  Preliminary Health‐Based Industrial/Commercial SRGs  4/1/2016   ☐  Site‐specific risk‐based cleanup level, or acceptable concentrations determined via  calculated cumulative risk. Enter details of methods used for determination/explanation:  6  EMP Form ver.1, October 23, 2014    Hazardous lead impacted soil, non‐hazardous impacted soil, and non‐impacted soil are  located in the proposed cut area on Parcel 32.  NC DOT will treat the hazardous lead impacted soil to  non‐hazardous levels and reuse the treated soil in a proposed privacy berm located on the Parcel 31.1  portion of the Brownfields footprint or dispose of the soil in a Subtitle D landfill.  The soil will likely be  disposed in a landfill.  NC DOT will also reuse the non‐hazardous impacted soil and non‐impacted soil  cut from Parcel 32 in the berm.   Re‐use or disposal of the treated hazardous soil will require NC DEQ  approval.   A hazardous soil and treatment removal  work plan dated April 26, 2016 was submitted to  NC DEQ for approval of these activities.   If placed in the berm, the treated soil will require 2 ft of  cover material or hardscape.  NC DOT would like to reuse non‐impacted soil and impacted soil below  the Industrial SRGs as cover material in the berm.  Additional soil samples were recently collected to  better define the non‐impacted soil in the proposed cut area on Parcel 32 and the level of  contamination (if impacted).  The supplemental soil sampling data are provided under separate cover.       5)  Check the following action(s) to be taken during excavation and management of said soils:    ☒  Manage fugitive dust from site:    ☒  Yes  ☐ No    If yes, describe method; If no, explain rationale:  Typical construction dust control measures  will be utilized such as wetting with water trucks or hoses to manage nuisance dust levels.    ☒  Field Screening:      ☒ Yes  ☐ No   If yes, describe method; If no, explain rationale:  Visual and olfactory, supplemented with field  OVA measurements if/where new areas of suspect soils are identified during construction.    ☒  Soil Sample Collection:    ☒ Yes   ☐ No   If yes, describe method (e.g., in‐situ grab, composite, stockpile, etc.); If no, explain rationale:   If suspect soil is encountered and field screening described above indicates potential for previously unknown contamination, the suspect soil will be stockpiled and covered in a secure area to allow construction to progress while samples are collected and analyzed, and results evaluated to determine the appropriate disposition of the stockpiled soil. Stockpiles will be placed on and covered with plastic sheeting; configured to minimize contact with surface flow, and will be placed to prevent erosion. Soil samples will be collected as a composite sample (except VOCs will be grab samples) from representative locations within the stockpile and analyzed as per below.  ☒  Stockpile impacted soil in accordance with NCDENR IHSB protocol in the current version of  the “Guidelines for Assessment and Cleanup”, and providing erosion control, prohibiting  contact between surface water/precipitation and contaminated soil, and preventing  contaminated runoff.   Explain any variances:    ☒   Analyze potentially impacted soil for the following chemical analytes:    ☒  Volatile organic compounds (VOCs) by EPA Method 8260    ☒  Semi‐volatile organic compounds (SVOCs) by EPA Method 8270  7  EMP Form ver.1, October 23, 2014    ☐   Metals RCRA List (8) (arsenic, barium, cadmium, chromium (speciated), mercury,  lead, selenium and silver)    ☒  Metals –Hazardous Substance List ‐14 (antimony, arsenic, beryllium, cadmium,  chromium (speciated according to IHSB protocol), copper, lead, manganese, mercury, nickel,  selenium, silver, thallium, and zinc)    ☐ Metals – EPA Priority Pollutant List – 13 (arsenic, beryllium, cadmium, chromium  (speciated according to IHSB protocol), copper, mercury, nickel, lead, antimony, selenium, silver,   thallium, and zinc)    ☒ Other Constituent(s) & Analytical Method(s):  PCBS by EPA Method 1668     ☒  Proposed Measures to Obtain Pre‐Approval for Reuse of Impacted Soil within the  Brownfields Property Boundary    ☒  Provide documentation of analytical report(s) to Brownfields Project Manager    ☒  Provide documentation of final location, thickness and depth of relocated soil on  site map to Brownfields Project Manager once known    ☐  Use geotextile to mark depth of fill material (provide description of material)    ☒  Manage soil under impervious cap ☒ or clean fill  ☒   Describe cap or fill: Soil impacted above Industrial SRGs will be covered with 2 ft of fill  below Industrial SRGs, a geotextile and 1 ft of fill below Industrial SRGs, or hardscape   (provide location diagram)    ☒ Confer with NC BF Project Manager if Brownfield Plat must be revised (or re‐ recorded if actions are Post‐Recordation).    ☒ Other: Note that impacted soil exceeds Industrial PSRGs    ☐ Final grade sampling of exposed soil (i.e., soil that will not be under buildings or permanent  hardscape): [if not checked provide rationale for not needing]   Provide diagram of soil sampling locations, number of samples, and denote Chemical  Analytical Program with check boxes below (Check all that apply):       ☐  Volatile organic compounds (VOCs) by EPA Method 8260    ☐  Semi‐volatile organic compounds (SVOCs) by EPA Method 8270    ☐   Metals RCRA List (8) (arsenic, barium, cadmium, chromium (speciated), mercury,  lead, selenium and silver)    ☐  Metals –Hazardous Substance List ‐14 (antimony, arsenic, beryllium, cadmium,  chromium (speciated according to IHSB protocol), copper, lead, manganese, mercury, nickel,  selenium, silver, thallium, and zinc)    ☐ Metals – EPA Priority Pollutant List – 13 (arsenic, beryllium, cadmium, chromium  (speciated according to IHSB protocol), copper, mercury, nickel, lead, antimony, selenium, silver,  thallium, and zinc)   ☐ Pesticides   ☐ PCBs    ☒ Other Constituents & Analytical Method:  Testing of final grade is not necessary  because import soil will be tested; soil has already been assessed; it is a heavy industrial setting; and  cover for soil impacted above Industrial SRGs is specified above  OFFSITE TRANSPORT & DISPOSITION OF EXCAVATED SOIL   NOTE: Unless soil will be transported offsite for disposal in a permitted facility under applicable  regulations, no contaminated or potentially contaminated soil may leave the site without approval  from the brownfields program.  Failure to obtain approval may violate a brownfields agreement,  8  EMP Form ver.1, October 23, 2014  endangering liability protections and making said action subject to enforcement.  Justifications  provided below must be approved by the Program in writing prior to completing transport activities.  ☒  Transport and dispose of impacted soil offsite (documentation of final disposition must be sent to  Brownfields Project Manager)   ☒  Landfill – analytical program determined by landfill    ☒  Landfarm or other treatment facility  If only petroleum impacts   ☐  Use as Beneficial Fill Offsite – provide justification:  Click here to enter text.   ☐  Use as Beneficial Fill at another Suitable Brownfields Site – (Note: a determination that a  site is a “Suitable Brownfields” site will require, at a minimum, that similar concentrations of the same  or similar contaminants already exist at both sites, use of impacted soil as beneficial soil will not  increase the potential for risk to human health and the environment at that site, and that notarized  documentation of the acceptance of such soil from the property owner of the receiving site is  provided to Brownfields.  Provide justification:  Click here to enter text.    MANAGEMENT OF UTILITY TRENCHES  ☐  Install liner between native impacted soils and base of utility trench before filling with clean fill  (Preferred)    ☒  Last out, first in principle for impacted soils (if soil  can safely be reused onsite and is not a  hazardous waste), i.e., impacted soils are placed back at approximately the depths they were  removed from such that impacted soil is not placed at a greater depth than the original depth from  which it was excavated.     ☐ Evaluate whether necessary to install barriers in conduits to prevent soil vapor transport, and/or  degradation of conduit materials due to direct impact with contaminants? Result: Yes □ No □   If no, include rationale here.   Click here to enter text.    If yes, provide specifications on barrier materials    Other comments regarding managing impacted soil in utility trenches:   .       PART 2.  GROUNDWATER  – Please fill out the information below and attach figure showing  distribution of groundwater contaminants at site    What is the depth to groundwater at the Brownfields Property?    The depth to groundwater is  approximately 10 ft below ground surface across the project area.    Is groundwater known to be contaminated by    ☐onsite   ☐ offsite   ☒ both   ☒ or unknown   sources?  Describe source(s):  Low level manganese was detected in groundwater above the 2L Standard on Parcel 32. The manganese is likely naturally occurring and no DEQ surface water quality criteria exists for manganese. Low level petroleum groundwater impacts were previously detected on the northern and western portions of Parcel 31. No groundwater samples have been collected in the proposed Brownfield footprint of Parcel 31.1. Impacted groundwater data is provided in tables and figures included in Appendix C.     9  EMP Form ver.1, October 23, 2014  What is the direction of groundwater flow at the Brownfields Property?   Based on historical  information groundwater flow is to the east‐southeast on the northern side of Parcel 31.     Will groundwater likely be encountered during planned redevelopment activities?    ☒ Yes    ☐  No  If yes, describe these activities:  Groundwater may be encountered during cut activities and/or  utility/drainage construction activities.  However, due to the apparent lack of impacts, groundwater is  not expected to be a significant redevelopment issue.    In the event that contaminated groundwater is encountered during redevelopment activities (even if  no is checked above), list activities for contingent management of groundwater (e.g., dewatering of  groundwater from excavations or foundations, containerizing, offsite disposal, discharge to sanitary  sewer, or sampling procedures):  If suspected contaminated groundwater gathers in an open  excavation, appropriate worker safety measures will be undertaken.  The accumulated water will be  allowed to evaporate, sprayed onto impacted areas for dust control, tested and disposed off‐site (if  impacted), or tested and discharged to the storm sewer (if not impacted above DEQ surface water  standards).      PART 3.  SURFACE WATER – Please fill out the information below.  Attach a map showing the location of surface water at the Brownfields Property.    Is surface water at the property known to be contaminated:    ☐  Yes  ☒  No       Will workers or the public be in contact with surface water during planned redevelopment activities?       ☐ Yes    ☒  No    In the event that contaminated surface water is encountered during redevelopment activities,  or  clean surface water enters open excavations, list activities for management of such events (e.g.  flooding, contaminated surface water run‐off, stormwater impacts):  If surface water run‐off gathers in  an open excavation determined during construction to be impacted, appropriate worker safety  measures will be undertaken.  The accumulated water will be allowed to evaporate, sprayed onto  impacted areas for dust control, tested and disposed off‐site (if impacted), or tested and discharged to  the storm sewer (if not impacted above DEQ surface water standards).     PART 4.  SEDIMENT – Please fill out the information below.    Is sediment at the property known to be contaminated:    ☐  Yes  ☒  No       Will workers or the public be in contact with sediment during planned redevelopment activities?       ☐ Yes    ☒  No    If yes, attach a map showing location of known contaminated sediment at the property.    In the event that contaminated sediment is encountered during redevelopment activities, list  activities for management of such events (stream bed disturbance):  If impacted sediment is  encountered or disturbed, impacted sediment will be managed in accordance with impacted soil  management procedures described above.    10  EMP Form ver.1, October 23, 2014      PART 5.  SOIL VAPOR – Please fill out the information below.    Do concentrations of volatile organic compounds at the Brownfields property exceed the following  vapor intrusion screening levels in the following media:    IHSB Residential Screening Levels:   Soil Vapor:    ☐ Yes      ☐  No     ☒  Unknown   Groundwater:  ☐ Yes      ☐  No     ☒  Unknown    IHSB Industrial/Commercial Screening Levels:  Soil Vapor:    ☐ Yes      ☐  No     ☒  Unknown   Groundwater:  ☐ Yes      ☐  No     ☒  Unknown    Attach a map showing the location of soil vapor contaminants that exceed site screening levels.     If applicable, at what depth(s) is soil vapor known to be contaminated?  Because no buildings are  proposed on the Brownfields site, no vapor intrusion sampling has been conducted on the subject  properties. There are widespread petroleum impacted soils on Parcel 32.  No VOCs were detected in a  groundwater sample collected from Parcel 32.  Low level petroleum constituents were detected in  groundwater samples collected on the northern and western portions of Parcel 31 outside of the  proposed Brownfields footprint (see Tables and Figures in Appendix C).    Will workers encounter contaminated soil vapor during planned redevelopment activities?       ☐ Yes    ☐  No  ☒  Unknown    In the event that contaminated soil vapor is encountered during redevelopment activities (trenches,  manways, basements or other subsurface work, list activities for management of such contact:        In  the event contaminated soil vapors are encountered during redevelopment activities, the area will be  evacuated and appropriate safety screening of the vapors will be performed.  If results indicate  further action is warranted, appropriate engineering controls (such as use of industrial fans) will be  implemented.      PART 6.  SUB‐SLAB SOIL VAPOR ‐please fill out the information below if existing buildings or  foundations will be retained in the redevelopment.    Are sub‐slab soil vapor data available for the Brownfields Property?    ☐ Yes   ☒  No  ☐  Unknown    If data indicate that sub‐slab soil vapor concentrations exceed screening levels, attach a map showing  the location of these exceedances.    At what depth(s) is sub‐slab soil vapor known to be contaminated?   ☐  0‐6 inches  ☐  Other,  If other  describe:             Will workers encounter contaminated sub‐slab soil vapor during planned redevelopment activities?   11  EMP Form ver.1, October 23, 2014      ☐ Yes    ☐  No   ☒  Unknown    In the event that contaminated soil vapor is encountered during redevelopment activities, list  activities for management of such contact:   In the event contaminated soil vapors are encountered  during redevelopment activities, the area will be evacuated and appropriate safety screening of the  vapors will be performed.  If results indicate further action is warranted, appropriate engineering  controls (such as use of industrial fans) will be implemented.        PART 7.  INDOOR AIR – Please fill out the information below .     Are indoor air data available for the Brownfields Property?    ☐   Yes   ☒  No    ☐  Unknown    If yes, attach a map showing the location where indoor air contaminants exceed site screening levels.    If the structures where indoor air has been documented to exceed risk‐based screening levels will not  be demolished as part of redevelopment activities, will workers encounter contaminated indoor air  during planned redevelopment activities?       ☐ Yes    ☐  No  ☐ Unknown    In the event that contaminated indoor air is encountered during redevelopment activities, list  activities for management of such contact:  Although not anticpated, in the event contaminated  vapors are encountered during redevelopment activities, the area will be evacuated and appropriate  safety screening of the vapors will be performed.  If results indicate further action is warranted,  appropriate engineering controls (such as use of industrial fans) will be implemented.       PART 8 – Vapor Mitigation System – Please fill out the information below .     Is a vapor intrusion mitigation system proposed for this Brownfields Property?         ☐ Yes    ☒  No  ☐ Unknown    If yes, provide the date the plan was submitted to the Brownfields Program.         Attach the plan.    Has the vapor mitigation plan been approved by the NC Brownfields Program?   ☐  Yes   ☒  No     ☐  Unknown  Has the vapor mitigation plan been signed and sealed by a North Carolina professional engineer?       ☐ Yes    ☒  No      What are the components of the vapor intrusion mitigation system?  ☐  Sub‐slab depressurization system  ☐  Sub‐membrane depressurization system  ☐  Block‐wall depressurization system  12  EMP Form ver.1, October 23, 2014  ☐ Drain tile depressurization system  ☐  Passive mitigation methods  ☐ Vapor barriers  ☐ Perforated piping vented to exterior  ☐  Other method:  Because there are no proposed buildings in this portion of the project area and the  existing buildings have been removed, no vapor mitigation system is planned for the site.      PART 9.  CONTINGENCY FOR ENCOUNTERING UNKNOWN TANKS, DRUMS, OR OTHER WASTE  MATERIALS  Please provide a contingency plan in the event unknown tanks, drums, fuel lines, landfills,  or other  waste materials are encountered during site activities.  Check the following activities that will be conducted prior to commencing  earth‐moving activities at  the site:  ☒ Review of historic maps (Sanborn Maps, facility maps)  ☒ Conducting geophysical surveys to evaluate the location of suspect UST, fuel lines, utility lines, etc.  ☒ Interviews with employees/former employees/facility managers/neighbors  Notification to State Brownfields Project Manager, UST Section, Fire Department, and/or other  officials, as necessary and appropriate, is required when new potential source(s) of contamination are  discovered.  See Notification Section on Page 1 for notification requirements.  POST‐REDEVELOPMENT REPORTING  In accordance with the site’s Brownfield Agreement, provide a report within the designated schedule  to the State Brownfields Project Manager.  ☒  Check box to acknowledge consent to provide a redevelopment summary report in compliance  with the site’s Brownfields Agreement.  APPROVAL SIGNATURES  Prospective Developer Date  Printed Name/Title/Company  NCDOT Signature on file Matt Bramblett PE/Principal/Hart & Hickman PC 5/6/16 Consultant Date Printed Name/Title/Company Date 13 EMP Form ver.1, October 23, 2014 I Ta b l e 1 Pa r c e l S u m m a r i e s Ch a r l o t t e L o c o m o t i v e a n d R a i l c a r M a i n t e n a n c e F a c i l i t y Ch a r l o t t e , M e c k l e n b u r g C o u n t y , N o r t h C a r o l i n a H& H J o b N o . R O W - 5 0 8 PI N  Nu m b e r  (D O T   Pa r c e l  ID  Nu m b e r ) P r o p e r t y  Ad d r e s s   Cu r r e n t  Pr o p e r t y  Ow n e r   Ac r e s I d e n t i f i e d  Pa s t  Us e s C u r r e n t  Us e  Environmental  Report  Summaries 07 3 2 6 2 1 5  (3 1 ) 13 3 6  S.  Gr a h a m   St r e e t NC  DO T Ap p r o x .  0. 9 0   (s o u t h e r n  po r t i o n   on l y ) Ba s e b a l l  st a d i u m ,  fi l m  di s t r i b u t o r s ,  tr u c k i n g   co m p a n i e s  an d  re p a i r ,  re t a i l  sa l e s ,  mi l l w o r k ,   HV A C  co m p a n y ,  pi p e  & fo u n d r y  wa r e h o u s e   an d  st o r a g e Ch a r l o t t e  Pip e  &  Fo u n d r y  wa r e h o u s e   an d  st o r a g e  ‐   Su m m a r y  Re p o r t  Ta n k  Ex c a v a t i o n  Op e r a t i o n s  Oc t o b e r  8, 1990  and  Limited  Site  Assessment  Report  (LSA) December  9, 2005   for  Vickers  Realty  (property  leased   to  Ra m c o n ,  In c .  fo r  sh i p p i n g  wa r e h o u s e )  (I n c i d e n t  13 1 3 7 ) ‐ Two  5,000 ‐gallon, one  4,000 ‐gallon, & one  2,000 ‐gallon  diesel  USTs  removed  in  1990. TPH  (up  to  16,000   mg / k g )  wa s  de t e c t e d  in  so i l  sa m p l e s  be n e a t h  th e  US T s  (additional  delineation  of  impacted  soils  was  completed  at  the  site). As  part  of   LSA  activities, seven   mo n i t o r i n g  we l l s  we r e  in s t a l l e d  at  th e  si t e .    Pe t r o l e u m  impacts  in  soil  samples  collected  from  monitoring  wells  exceeded  soil  to  groundwater  and  residential   MS C C s  an d  be n z o  (a )  py r e n e  ex c e e d e d  th e  in d u s t r i a l / c o m m e r c i a l  MSCC  in  one  soil  sample  location.  Petroleum  groundwater  impacts  were  also  detected  slightly   ab o v e  th e  2L  St a n d a r d . ‐DE N R  is s u e d  a  NF A  st a t u s  in  20 0 6  wi t h  a  No t i c e  of  Re s i d u a l  Petroleum  (NORP) restricting  groundwater  use  and  soil  restrictions  (impacted  soil  area  can  only  be   di s t u r b e d  fo r  re m e d i a t i o n  pu r p o s e s ) . T h i s  re l e a s e  ar e a  is  located  outside  of  the  proposed  Brownfields  portion  of  the  property. ‐ Ge o p h y s i c a l  Su r v e y  Re p o r t  Ap r i l  9, 20 1 1  ‐   30  ta r g e t s  (o n  Parcels  07326215, 07326203, 07326207,07326231, & 07326201) w/ "low  confidence" were  identified   in d i c a t i n g  ch a r a c t e r i s t i c s  of  po t e n t i a l  dr u m s  or  US T s .  ‐   PS A  Ju l y  16 ,  20 1 5  ‐   Im p a c t e d  so i l  ab o v e  th e  DE N R  ta r g e t  levels  including  DRO, PAHs  and  manganese  were  detected  on  Parcel  31. An  estimated  9,900  cubic  yards   (1 4 , 8 0 0  to n s )  of  im p a c t e d  so i l  ap p e a r  to  be  pr e s e n t  on  entire  DOT  Parcel  31.  Groundwater  is  impacted  with  low  level  naphthalene  and  manganese  above  2L   St a n d a r d s  be n e a t h  Pa r c e l  31 .  Th e  de p t h  to  gr o u n d w a t e r  is  approximately  8  to  13  ft  below  grade. 07 3 2 6 2 1 6  (3 2 ) 13 2 0  S.  Gr a h a m   St r e e t NC  DO T 1 . 6 2 5 Sm i t h  Me t a l  & Ir o n  ju n k y a r d  an d  plu m b i n g   su p p l y / d i s t r i b u t o r Va c a n t  (F o r m e r   Fe r g u s o n  Plu m b i n g   Su p p l y )  ‐   PS A  De c e m b e r  1,  20 1 4  ‐   Wi d e s p r e a d  im p a c t e d  so i l  is  present. The  primary  contaminants  are  TPH, PCBs, and  metals  (particularly  lead).  An  estimated  30,000  to   35 , 0 0 0  to n s  of  im p a c t e d  so i l  ap p e a r  to  be  pr e s e n t .    A  po r t i o n  of  the  impacted  soil  exceeds  the  characteristically  hazardous  waste  threshold  for  lead. Three  possible   US T s  ou t s i d e  of  th e  pr o p o s e d  cu t  ar e a  we r e  id e n t i f i e d  on  site  via  EM/GPR. ‐ Ha z a r d o u s  So i l  Re m o v a l  Wo r k  Pl a n  an d  Gr o u n d w a t e r  Results  April  26, 2016  ‐ A  temporary  monitoring  well  was  installed  and  sampled  to  determine  if  lead  was   le a c h i n g  to  gr o u n d w a t e r  ne a r  th e  ha z a r d o u s  le a d  im p a c t e d  soil  area.   No  lead  impacts  were  detected  in  groundwater. Low  level  manganese  was  detected  in   gr o u n d w a t e r  ab o v e  th e  2L  St a n d a r d .  Th e  ma n g a n e s e  is  likely  naturally  occuring. S:\ A A A - M a s t e r P r o j e c t s \ N C D O T R i g h t - o f - W a y - R O W \ R O W - 5 0 0 s \ R O W - 5 0 8 P - 3 8 0 0 C R I S P B F M a n a g e m e n t \ R e v i s e d E M P \ B F P a r c e l S u m m a r i e s T a b l e 1 . x l s x 5/ 4 / 2 0 1 6 Table 1 (Page 1 of 1)Hart & Hickman, PC SITE 0 2000 4000 APPROXIMATE SCALE IN FEET N U.S.G.S. QUADRANGLE MAP QUADRANGLE 7.5 MINUTE SERIES (TOPOGRAPHIC) CHARLOTTE EAST, NC 1991 TITLE PROJECT SITE LOCATION MAP CHARLOTTE LOCOMOTIVE AND RAILCAR MAINTENANCE FACILITY CHARLOTTE, MECKLENBURG COUNTY, NORTH CAROLINA DATE: JOB NO: REVISION NO: FIGURE: 2-2-16 0 1ROW-508 2923 S. Tryon Street, Suite 100 Charlotte, NC 28203 704.586.0007(p) 704.586.0373(f) Appendix A NC DOT Plan Sheets H515 29 SWSW SW STORAGE PLATFORMS S CONC CONC CONC S S SS to Sta. 128+00 (Phase 1A) Plan - TRK5 Sta. 116+50 4" PVC S/L CO 700.94 TO GASTONIA TO GASTONIA TO CONCORD TO CONCORD VICINITY MAP 4 STATE STATE PROJECT REFERENCE NO. STATE PROJ. NO.F. A. PROJ. NO.DESCRIPTION NO. TOTAL SHEETS N.C. SHEET A R T MEN N A S O H NC DEPARTMENT OF TRANSPORTATION CN D E P T O F TRA SPORT T I O N T A TEOFN RT CAR O LI N A 0 0 0 PROFILE (HORIZONTAL) GRAPHIC SCALES PLANS PROFILE (VERTICAL) LOCATION: TYPE OF WORK: 0 00 C O N T R A C T : T I P P R O J E C T : PROJECT LENGTH RIGHT OF WAY DATE: LETTING DATE: 2012 STANDARD SPECIFICATIONS N CNORTH CAROLINA D C N 50 100 50 10 20 100 50 50 10 NCDOT PROJECT MANAGER CRAIG M. NEWTON, P.E. RAIL PROJECT ENGINEER STEVEN C. NORIEGA, P.E. HYDROLOGY ENGINEER ROADWAY ENGINEER Prepared in the Offices of: ENGINEER HYDRAULICS P.E. SIGNATURE:SIGNATURE: P.E. SIGNATURE: P.E. RAIL ENGINEER ENGINEER ROADWAY LENGTH OF STRUCTURE TIP PROJECT LENGTH OF RAIL TIP PROJECT TOTAL LENGTH OF TIP PROJECT RAIL PROJECT ENGINEER 3/4/2016 simmonbt I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CK_Track_Rail\Plot Sheets\4015156_SHT_1.dgn MECKLENBURG COUNTY rris Mo Berg A R C H I T E C T S (704) 552-5800 FAX (704) 552-7420 CHARLOTTE, NC 28208 1401 WEST MORREHEAD STREET, SUITE 125 SUBMITTAL: DATE: NS MAINLINE RAILROAD ROADBED (MP 378.26) _ 77 _ 77 _ 277 Norfolk Corp.Southern BEGIN PROJECT END PROJECT 74 (49 (160 (49 (27 29 (27 CHARLOTTE Foundry Pipe & Charlotte Park Neighborhood Whilmore Stadium America Bank of _ 277 74 ( N C 2 7 ) M O R E H E A D S T R E E T P A L M E R S T R E E T -TRK6- -TRK5- -TRK7- P E N M A N S T R E E T (I-27 7) J O H N B E L K F R E E W A Y S U M M I T A V E N U E (SR 1187)CARSO N BOULEVARD TO EAST OF SUMMIT AVENUE (MP 378.74) 0.0 MILES 0.48 MILES 0.48 MILES PE, UTL PE P-2918F P - 2 9 1 8 F TO MP 378 TO CONCORD TO M P 3 7 9 TO GA S TON IA 1 4 0 1 3 5 1 3 0 1 2 5 12 0 11 5 MAIN TRACKS EXIST. NSR. 49999.3.STR8 -TRK5- STA. 140+72.48 PROP. TRACK #5 END TIP PROJECT P-2918F -TRK5- STA. 116+50.00 PROP. TRACK #5 BEGIN TIP PROJECT P-2918F (BY OTHERS) FUTURE TRACK OPERATIONS AND FACILITIES RAIL DIVISION STATE OF NORTH CAROLINA PLATFORM PROP. SERVICE 100% PLANS 5 (BY OTHERS) FUTURE -TRK7- GRAHAM STREET N O RTH CARO LIN A P R OFESS I ONA L E NGINEER S T E V EN C H R ISTOPHER NORIEGA033404 SEAL NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. MORIAH B. ELLINGTON, P.E. JEFF E. BLIND, P.E. $TOT$G-01 SCO# 100863403 FACILITY AND OFFICE BUILDING PROPOSED MAINTENANCE FACILITY YARD LOCOMOTIVE & RAILCAR MAINTENANCE AND DRAINAGE AND PAVING FOR THE TRACKWORK, RAILROAD ROADBED GRADING, N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL FEBRUARY 29, 2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 1 - A . d g n s i m m o n b t PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL SHEET NUMBER SHEET TITLE 1-A INDEX OF DRAWINGS SHEET NUMBER SHEET TITLE DocuSign Envelope ID: 2C49F13A-7049-4347-B41F-0AF13BBBEBC4 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 1 - B . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL Existing Edge of Pavement Existing Curb Proposed Slope Stakes Cut Proposed Slope Stakes Fill Proposed Wheel Chair Ramp WCR Existing Metal Guardrail Existing Cable Guiderail Proposed Guardrail Pavement Removal Baseline Control Point RIGHT OF WAY: Existing Right of Way Marker Existing Right of Way Line h Existing Control of Access Proposed Control of Access Proposed Right of Way Line C F Existing Easement Line Proposed Temporary Construction Easement Proposed Temporary Drainage Easement Proposed Permanent Drainage Easement Proposed Permanent Utility Easement HYDROLOGY: Stream or Body of Water Hydro, Pool or Reservoir Flow Arrow Disappearing Stream Spring ; z v W K Proposed Lateral, Tail, Head Ditch False Sump Proposed Cable Guiderail MAJOR: Bridge, Tunnel or Box Culvert Bridge Wing Wall, Head Wall and End Wall MINOR: Head and End Wall Pipe Culvert Footbridge Paved Ditch Gutter UTILITIES: ROADS AND RELATED FEATURES: Existing Power Pole Proposed Power Pole P U/G Power Cable Hand Hole Power Manhole Power Line Tower Power Transformer Existing Joint Use Pole Proposed Joint Use Pole Existing Telephone Pole Proposed Telephone Pole Telephone Manhole Telephone Booth Telephone Pedestal U/G Telephone Cable Hand Hole R } T p ] Q l e ] / b H-Frame Pole O O POWER: TELEPHONE: Telephone Cell Tower Recorded U/G Power Line Recorded U/G Telephone Cable Designated U/G Telephone Cable (S.U.E.*) Recorded U/G Telephone Conduit Designated U/G Telephone Conduit (S.U.E.*) Recorded U/G Fiber Optics Cable WATER: Water Manhole Water Meter Water Valve Water Hydrant Recorded U/G Water Line 4 I H a TV: TV Satellite Dish TV Pedestal TV Tower U/G TV Cable Hand Hole Recorded U/G TV Cable Recorded U/G Fiber Optic Cable Designated U/G Fiber Optic Cable (S.U.E.*) r | I ] GAS: Gas Valve Gas Meter Recorded U/G Gas Line n c SANITARY SEWER: Sanitary Sewer Manhole Sanitary Sewer Cleanout U/G Sanitary Sewer Line Recorded SS Forced Main Line Designated SS Forced Main Line (S.U.E.*) d o A/G Water Above Ground Gas Line A/G Gas Above Ground Water Line Above Ground Sanitary Sewer A/G Sanitary Sewer MISCELLANEOUS: Utility Pole O F S 3 Utility Pole with Base Utility Located Object Utility Traffic Signal Box Utility Unknown U/G Line ? CONC CONC WW v v Drainage Box: Catch Basin, DI or JB Storm Sewer Storm Sewer Manhole m U/G Tank; Water, Gas, Oil A/G Tank; Water, Gas, Oil BOUNDARIES AND PROPERTY: State Line County Line Township Line City Line Reservation Line Property Line Existing Iron Pin Property Corner Property Monument Existing Fence Line Proposed Woven Wire Fence Proposed Chain Link Fence Proposed Barbed Wire Fence g F 123 Existing Wetland Boundary Proposed Wetland Boundary Existing Endangered Animal Boundary Existing Endangered Plant Boundary BUILDINGS AND OTHER CULTURE: Area Outline Gas Pump Vent or U/G Tank Cap Church School Dam Sign Small Mine Well V M WW S x Foundation S Building y y VEGETATION: Single Tree X Y Vineyard Single Shrub Hedge Woods Line Orchard Vineyard RAILROADS: RR Abandoned RR Dismantled S FLOW Designated U/G Power Line (S.U.E.*) Designated U/G Fiber Optics Cable (S.U.E.*) Designated U/G Water Line (S.U.E.*) Designated U/G TV Cable (S.U.E.*) Designated U/G Gas Line (S.U.E.*) U/G Test Hole (S.U.E.*) WLB EIP B ECM CONC HW CB MILEPOST 35 SWITCH Cemetery EXISTING STRUCTURES: Parcel / Sequence Number E AATUR End of Information E.O.I. RAIL DIVISION STATE OF NORTH CAROLINA Abandoned According to Utility Records WLB EAB EPB R W R W R W C A E TDE PDE PUE S P P T T TC TC T FO T FO W W TV TV TV FO TV FO G G SS FSS FSS ?UTL Jurisdictional Stream JS Buffer Zone 1 Buffer Zone 2 BZ 1 BZ 2 Wetland Proposed Permanent Easement with Iron Pin and Cap Marker Proposed Temporary Utility Easement TUE Iron Pin and Cap Marker Proposed Right of Way Line with Concrete or Granite Marker Proposed Right of Way Line with DUEProposed Permanent Drainage / Utility Easement Existing Track To Be Retained Existing RR Signal Milepost Existing Track to be Removed Proposed Track Proposed Turnout Proposed Milepost Existing Switch 1-B Building Removal CONVENTIONAL PLAN SHEET SYMBOLS Proposed Platform DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 1 - C . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEALMISCELLANEOUS: TRACK ALIGNMENT - VERTICAL DRAINAGE 0s s c TRACK ALIGNMENT - HORIZONTAL L STB WSP RCP RCBC INV FF DIA DI CI/CIP BCCMP Stone Box Culvert Welded Steel Pipe Reinforced Concrete Pipe Reinforced Concrete Box Culvert Invert Filter Fabric Diameter Drop Inlet Cast Iron Pipe Bituminous Coated Corrugated Metal Pipe Spiral Deflection Spiral Angle Curve Angle VPT VPI VPC T/R / T/RAIL R L EL/ELEV MISCELLANEOUS (CONT'D): Vertical Point of Tangency Vertical Point of Intersection Vertical Point of Curvature Top of Rail Rate of Change of Gradient, per 100 Ft Vertical Curve Length Elevation ABBREVIATIONS Y X TS TO ST SPI SC RHTO R PT PS POT PINC PI/TO PIt PIc PC Ls LHTO L I Eu Ea Dc CS CP CD Spiral Tangent Offset Spiral Tangent Length to Offset Tangent to Spiral Turnout Spiral to Tangent Point of Intersection (Spiral) Spiral to Curve Right Hand Turnout Radius Point of Tangency Point of Switch Point on Tangent Point of Intersection,No Curve Point of Intersection/Turnout Point of Intersection (Tangent) Point of Intersection (Circular Curve) Point of Curvature Length of Spiral Left Hand Turnout Length of Curve Curve Intersection Angle Unbalanced Superelevation (Inches) Actual Superelevation (Inches) Degree of Curvature Curve to Spiral Control Point Cant Deficiency 1-C WB W/ W VERT VAR V TYP TRK7 TRK6 TRK5 TRK SY SWM STA ST SR SHT SHLDR SEG SB S S.U.E. RT RR RH REQ'D RD R/W PSRM PROP PGL PAV'T/PVMT OHU NS/NSR NO NCRR NB Westbound With West Vertical Varies Velocity (MPH) Typical Prop. Track #7 Prop. Track #6 Prop. Track #5 Track Square Yards Storm Water Management Station Street State Route Sheet Shoulder Segment Southbound South Subsurface Utility Engineering Right Railroad Righthand Required Road Right -of-Way Permanent Soil Reinforcement Mat Proposed Profile Grade Line Pavement Overhead Utility Norfolk Southern Railway Number North Carolina Railroad Northbound UNCL NIC N/A N MPH MP MIN MAX LT LH LF L&S HW HORIZ GRD FT FND F EX/EXIST EST ESMT EMBT EB E DWG DR CTL&S CONST CONC CLR CLEAR CL CB C C BLVD BLDG BK B AVE AH AEI ABS ABC Unclassified Not in Contract Not Applicable North Miles Per Hour Milepost Minimum Maximum Left Lefthand Linear Feet Line & Surface Headwall Horizontal Ground Feet Foundation Fill Existing Estimated Easement Embankment Eastbound East Drawing Drive Cut, Throw, Line, and Surface Construction Concrete Clear Clearance Class Catch Basin Cut Centerline Boulevard Building Back Baseline Avenue Ahead Automatic Equipment Identification Absolute Aggregate Base Course DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 1-D 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 1 D .d g n s i m m o n b t PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 10' ALLEY GAS LINE LOCATION PER FIELD MARKINGS GAS LINE LOCATION PER FIELD MARKINGS PIEDMONT NATURAL GAS 5' RIGHT OF WAYDEED BOOK 8320, PAGE 104 CITY OF CHARLOTTE 15' SANITARY SEWER EASEMENT DEED BOOK 1290, PAGE 333 D E E D B O O K 1 2 9 0, P A G E 400 MERRIMAN AVENUE CLOSED 05/26/1998 RES. BK. 35, PG. 60 DEED BK. 9808, PG. 811 RAILROAD STREET CLOSED 05/26/1998 RES. BK. 35, PG. 63 DEED BK. 9808, PG. 805 RAILROAD STREET (NEVER OPENED) RAILROAD STREET (NEVER OPENED) RAILROAD STREET (NEVER OPENED) WEST PALMER STREE T CLOSED 08/28/198 9 RES. BK. 25, PG. 34 8 DEED BK. 61 6 1 , PG. 81 2 54" WATER LINE 30' WATERLINE EASEMENT AGREEMENT DEED BK. 5249, PG. 819 MERRIMAN AVENUE 40' PUBLIC R/W (C.O.C.) L A R C H STR EE T S U M MIT A V E N U E 6 0' P U B LIC RIG H T OF W A Y ( C.O.C.) WINONA STREET (C.O.C.) SOUTH GRAHAM STREET 40' PUBLIC RIGHT OF WAY (C.O.C.) (C.O.C.) C O M M ERCE STREET B L A N D S T R E E T INTERSTATE HIGHWAY 77 VARIABLE WIDTH PUBLIC R/W C A RS O N B O ULE V A R D V A RIABLE WIDT H P UBLIC R/ W OUTSIDE R/W OUTSIDE R/W 10' ALLEY WHITE CONSOLIDATED INDUSTRIES 10.952 ACRES DEED BOOK 13251, PAGE 604 PARCEL #11910318 ZONED I-1 FOUNDRY COMPANY 5.641 ACRES DEED BOOK 8604, PAGE 680 PARCEL #07326203 ZONED I-2 CHARLOTTE PIPE AND FOUNDRY COMPANY 0.224 ACRES DEED BOOK 23173, PAGE 872 PARCEL #07326207 ZONED I-2 CHARLOTTE PIPE AND FOUNDRY COMPANY 3.744 ACRES DEED BOOK 21663, PAGE 243 PARCEL #07326215 ZONED I-2 CHARLOTTE PIPE AND RJS/STS LLC 1.953 ACRES DEED BOOK 18331, PAGE 364 PARCEL #07326216 ZONED I-2 TRANSPORTATION 1.891 ACRES DEED BOOK 16687, PAGE 370 PARCEL #07326218 ZONED I-2 DEPARTMENT OF TRANSPORTATION 2.296 ACRES DEED BOOK 14533, PAGE 856 PARCEL #07326219 ZONED I-2 DEPARTMENT OF TRANSPORTATION 1.645 ACRES DEED BOOK 16757, PAGE 807 PARCEL #07326803 ZONED I-2 DEPARTMENT OF PIEDMONT NATURAL GAS DEED BOOK 8095, PAGE 329 PARCEL #11910319 22 23 24 25 MAP BOOK 230, PAGE 297 BLOCK 22 SPEAR PROPERTIES LP DEED BOOK 7153, PAGE 633 PARCEL #11910320 ROBERT R. SINYARD DEED BOOK 4673, PAGE 169 PARCEL #11910322 CHARLOTTE PIPE & FOUNDRY CO. DEED BOOK 23173, PAGE 872 PARCEL #07326231 H & S ROOFING CO. DEED BOOK 9183, PAGE 203 PARCEL #07326232 BASCOM V. BELK DEED BOOK 4944, PAGE 512 PARCEL #07326214 HAL H. CONROY DEED BOOK 6732, PAGE 517 PARCEL #07326217 FOUNDRY COMPANY 0.885 ACRES DEED BOOK 23469, PAGE 107 PARCEL #07326804 ZONED I-2 CHARLOTTE PIPE AND CLARENCE W. WALL DEED BOOK 5992, PAGE 341 PARCEL #07326807 6 5 4 3 2 1 DEPARTMENT OF TRANSPORTATION DEED BOOK 14533, PAGE 856 PARCEL #07326220 BURKE MANAGEMENT LLC DEED BOOK 16872, PAGE 142 PARCEL #07326221 BURKE MANAGEMENT LLC DEED BOOK 16872, PAGE 142 PARCEL #07326222 ALBRIGHT PROPERTIES LLC DEED BOOK 8881, PAGE 538 PARCEL #07326223 ALBRIGHT PROPERTIES LLC DEED BOOK 8881, PAGE 538 PARCEL #07326224 ALBRIGHT PROPERTIES LLC DEED BOOK 8881, PAGE 538 PARCEL #07326225 1 2 3 4 5 6 ADJOINING PROPERTY OWNERS Dewberry & Davis , Inc. 6135 LAKEVIEW ROAD, SUITE 400 CHARLOTTE, NORTH CAROLINA 28269 PHONE: 704.509.9918 FAX: 704.509.9937 License: F-0679 NOTES SURVEYOR'S CERTIFICATION PROFESSIONAL LAND SURVEYOR L-2666 DATE I, TIMOTHY A. RUDOLPH, CERTIFY THAT THIS PLAT WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL FIELD SURVEY MADE UNDER MY SUPERVISION FROM DEED REFERENCES 1 - 10 MECKLENBURG COUNTY REGISTER OF DEEDS, OF PRECISION AS CALCULATED IS 1:10,000+ AND THAT THIS MAP MEETS THE REQUIREMENTS OF THE STANDARDS OF PRACTICE FOR LAND SURVEYING IN NORTH WITNESS MY ORIGINAL SIGNATURE, REGISTRATION NUMBER AND SEAL THIS 19TH DAY OF SEPTEMBER, 2011. REFERENCES THAT THE BOUNDARIES NOT SURVEYED ARE CLEARLY INDICATED, THAT THE RATIO CAROLINA (21 NCAC 56. 1600). N .C . G R I D NO R T H NA D 83 1. ALL DISTANCES SHOWN ARE HORIZONTAL MEASUREMENTS. 2. HORIZONTAL DATUM BASE: NAD83 FROM GPS OBSERVATIONS. 3. THIS MAP IS NOT PREPARED FOR RECORDATION AS PER G.S. 47-30. 4. ZONING INFORMATION, IF SHOWN, IS AS PROVIDED BY THE MECKLENBURG COUNTY GIS. 5. THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL TITLE SEARCH. NO TITLE REPORT HAS BEEN SUPPLIED TO SURVEYOR. 1. DEED BOOK 20733, PAGE 227 (TITLE) 2. DEED BOOK 8604, PAGE 680 (TITLE) 3. DEED BOOK 21663, PAGE 243 (TITLE) 4. DEED BOOK 18331, PAGE 364 (TITLE) 5. DEED BOOK 16687, PAGE 370 (TITLE) FRRS FNC FRB FIR FIP NPS- Topographic Survey of - NCDOT Rail VMF - CLT SCALE DRAWN BY PROJECT NO. DATE Mecklenburg County, North Carolina CAD FILE BAR SCALE SEPTEMBER 19, 2011 1"=100' M. DENNIS 50046316 50046316-topo.DWG 0 50 100 200 300 Located within the City of Charlotte, SITE VICINITY MAP NOT TO SCALE N CLARKSON STREETINTERSTATE 77JOHN BELK FREEWAY MINT STREET S U M MIT STRE E T CARSO N BO ULEVARD WILMORE DRIVE MERRIMAN AVENUE RAILROAD WIN O N A GRAHAM PALMERPEN MA N SITE 6. DEED BOOK 14533, PAGE 856 (TITLE) 7. DEED BOOK 16756, PAGE 807 (TITLE) 8. DEED BOOK 23469, PAGE 107 (TITLE) 9. DEED BOOK 3825, PAGE 684 (TITLE) 10. DEED BOOK 13251, PAGE 604 (TITLE) 11. DEED BOOK 5249, PAGE 819 (WATER LINE) 12. DEED BOOK 9808, PAGE 805 (STREET CLOSURE) 13. DEED BOOK 9808, PAGE 811 (STREET CLOSURE) 14. DEED BOOK 1290, PAGE 333 (SEWER EASEMENT) 15. DEED BOOK 1290, PAGE 400 (SEWER EASEMENT) 16. DEED BOOK 8320, PAGE 104 (NAT. GAS EASEMENT) 17. MAP BOOK 230, PAGE 297 18. MAP BOOK 134, PAGE 427 19. MAP BOOK 42, PAGE 905 20. CHARLOTTE PIPE AND FOUNDRY PARCEL DIVISION SURVEY, BY TIMOTHY A. RUDOLPH, PLS, DATED 02/09/09 21. CHARLOTTE PIPE AND FOUNDRY / RLS STS LLC. PARCEL DIVISION SURVEY, BY TIMOTHY A. RUDOLPH, PLS, DATED 02/03/09 RAILROAD SPURLINE RAILROAD SPURLINE RAILROAD SPURLINE RAILROAD MAINLINE TRACK 1RAILROAD MAINLINE TRACK 2 N.C.G.S. MONUMENT "MO44" N 550,071.36 E 1,449,772.53 S 2 8 ° 28 ' 3 9 " W 9 7 48 .30 ' (G R O UN D ) 9 7 4 6 .77 ' (G R I D ) C O M B I N E D S C A LE F A C T O R : 0 .99 9 8 4 3 9 3 PIEDMONT NATURAL GAS DEED BOOK 8223, PAGE 221 PARCEL #11910326 Existing Property Line .................................. Existing Gas Line .......................................... Existing Water Line ...................................... Property Corner .................................................................................... Control Monument ................................................................................ Railroad R/W Line ......................................... Railroad Rails ................................................. Legend Computed Point (No Iron Set) ............................................................. Adjoining Property Line ............................... Found Railroad Spike .......................................................................... Found Nail in Concrete ....................................................................... Found Rebar ........................................................................................ Found Iron Rod ................................................................................... Found Iron Pipe .................................................................................. No Point or Iron Set ............................................................................ N L-2666 SEAL LA N D SURVEYOR A IL O RACHTRON RA.Y H TO UDOLP L AN OI SSEFORP H O T I MPreliminary P l a t N o t f o r R ec o r d a ti on , C onv e y a n ce o r S a l e s CHARLOTTE PIPE & FOUNDRY CO. DEED BOOK 1801, PAGE 184 PARCEL #07326230 CHARLOTTE PIPE & FOUNDRY CO. DEED BOOK 1801, PAGE 184 PARCEL #07326230 R/W R/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W NORFOLK SOUTHERN RAILROAD 200' PRIVATE RIGHT OF WAY 200' PRIVATE RIGHT OF WAY NORFOLK SOUTHERN RAILROAD FOUNDRY COMPANY 1.197 ACRES DEED BOOK 20733, PAGE 227 PARCEL #07326201 ZONED I-2 CHARLOTTE PIPE AND ZONING NOTES 1. SETBACKS FOR ZONING CLASSIFICATION I-1 ARE AS FOLLOW: FRONT: 20 FEET, SIDE: 0/5 FEET AND REAR 10 FEET. 2. SETBACKS FOR ZONING CLASSIFICATION I-2 ARE AS FOLLOW: FRONT: 20 FEET, SIDE: 0/5 FEET AND REAR 10 FEET. MBSLMinimum Building Setback Line ...................................................... 3. NO SETBACK IS REQUIRED IN INDUSTRIAL ZONING DISTRICTS ALONG RAILROAD RIGHT OF WAYS. 4. SCREENING BUFFERS MAY BE REQUIRED PER CHAPTER 12, PART 3 OF THE CITY OF CHARLOTTE ZONING ORDINANCE. FMNFound Magnail Nail ............................................................................ OWNED BY NCDOT 0 W NED B Y NC DO T NCDOTNorth Carolina Department of Transportation................................ C.O.C.Owned by City of Charlotte ............................................................... SWIMSurface Water Improvement and Management................................ SWIM BUFFER SWIM BUFFER SWIM BUFFER SWIM BUFFER SWIM BUFFER 6. SWIM BUFFER AS SHOWN IS APPROXIMATED PER MECKLENBURG COUNTY GIS. 2769713.23TR3 / 16 BIR 2874713.17FCAP WM WM W M WM WM WM WM WM WM WM WM WM WM WM WM W M WV WVWV WV WVWV WV WV WV W V WV WV WV WVWV WV W V WV WV WV WV CONC CONC 69069570070571 0 7 1 5 740 745750 750 745 740 735 730 725 720 72 0725730 730 730 73 0 7 2 5 7 2 0 720 725 725 72 5 7 2 0 715 715 710 710705 705 710 71572 0 720 720 715 71 5 715 7 1 571 0 710 715 710 705 710 71 5 700 715 710 7 05 7 0 0 695 690 690 695 700 710 71 0 705 705 715 710 705 700695 695 700 700 700 700 695 690 695 695 690 6 9 5 690 690690690 690 690 685 68 0 685 685 685 680675 6 7 5 6 70 6 6 5 68 0 68 5 685 685 665 670675 680 665 6 6 5 66 0 6 55 650645645 715 7 1 5 7 1 5 710 710 705 710 6 9 0 695 700 700 695 7 0 0 700 705 705 705 70 5 705 705 7 1 0 7 1 5 7 2 0 725 705 7 1 0 715 710 705 7 1 0 71 5 72 5 7 2 0 725730 735 730 72 5 720 715 710705 710 715 720 725 730 735 730725720 715710 745 745 7 4 0 73 5 73 0 7 25 7 2 0 7 15 71 0 710705 710710 7 2 0 715710 700 740 7 35 655650645 645 650 655 660 665 670 675 680 6 6 0 660 665 670 675 680 685 655660 665 670 675680 680 685680675670 675 68 0 685 690 690 690 685 685 685 69 5 695 700 685645650655660665 D D D D D D D DD D D WM WM WM WM WM WM WM WM WM WV WVWV WV WV WV WV WV WV WV WV WVWV WM WMWM WM WV GM GV GV GV G M GV GV G V GV GVGV GV GV 7. ALL BOUNDARY INFORMATION IS TAKEN FROM REFERENCE 22. 22. BOUNDARY SURVEY OF NCDOT RAIL VMF - CLT, BY TIMOTHY A. RUDOLPH, PLS, DATED 08/23/2011 BUILDING (TYPICAL) BOUNDARY INFORMATION AS SHOWN IS TAKEN FROM REFERENCE 22 50' PUBLIC RIGHT OF WAY 50' PUBLIC RIGHT OF WAY 7 7 PENMAN STREET (C.O.C.) 50' PUBLIC RIGHT OF WAY PALMER STREET (C.O.C.) 35' PUBLIC RIGHT OF WAY Sanitary Sewer Manhole...................................................................... Storm Water Manhole ......................................................................... Water Valve .......................................................................................... Water Meter ......................................................................................... Catch Basin .......................................................................................... Gas Valve ............................................................................................. Gas Meter ............................................................................................ DI DI DI DI DI DI DI DI CB CB CB CB CB CBCB CB CB CB CB CB CB CB CB CB CB CB S D WV WM CB GM GV TBM ELEV= BM#1 CHISELED SQUARE 680.75 TBM ELEV= USGS (C 41) DISK 682.12 TBM ELEV= BM#3 NAIL IN 18" ELM 702.69 TBM ELEV= NCGS (RV 106) RIVET 684.54 700 700 695 690 685 685 680 675 67 5 680 68 5 6 8 5 6 4 5 65 0 6 5 5 6 6 0 685 680 685 675 675 WHITE CONSOLIDATED INDUSTRIES 0.693 ACRES DEED BOOK 14172, PAGE 689 PARCEL #11910398 ZONED I-2 R/WR/W R/W R/W 40' PUBLIC R/W (C.O.C.) MAP BOOK 230, PAGE 297 BLOCK 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 50' P U B LIC R/ W (C.O.C.) WHITE CONSOLIDATED INDUSTRIES 7.371 ACRES DEED BOOK 14172, PAGE 689 PARCEL #11910399 ZONED I-1 & R-8 #11910396 PARCEL #11910395 PARCEL #11910315 PARCEL #11910314 PARCEL 705 710 715 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 .d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL EXISTING GROUND EXISTING GROUND 40:1 40:1 14.OOFT (MIN.) (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K VARIES 43.02FT TO 60.83FT 18.27FT TO 29.19FT VARIES (MIN.) BALLAST 8" 14.OOFT (MIN.)14.00FT (TYP) VARIES 40.85FT TO 43.02FT VARIES 29.19FT TO 41.74FT C /L P R O P . T R A C K # 5 (- T R K 5 -) C /L P R O P . T R A C K # 5 (- T R K 5 -) 14.00FT (TYP) = 12" OUTSIDE OF CURVES SW = 6" FOR TANGENT TRACK & INSIDE OF CURVES = 12" OUTSIDE OF CURVES SW = 6" FOR TANGENT TRACK & INSIDE OF CURVES (B Y O T H E R S ) C /L F U T U R E T R A C K (B Y O T H E R S ) C /L F U T U R E T R A C K (T O R E M A I N ) C / L E X I S T . M A I N T R A C K (T O R E M A I N ) C / L E X I S T . M A I N T R A C K (T O R E M A I N ) C / L E X I S T . M A I N T R A C K (T O R E M A I N ) C / L E X I S T . M A I N T R A C K REQUESTED) (ADDITIONAL SURVEY CRASH PROTECTION WITH PROPOSED TO REMAIN BRIDGE COLUMN EXIST. I-277 40:12:12: 1 2:1 2: 1 2:1 2:1 2: 1 (MIN.) BALLAST 8" LOW RAIL TOP OF PROPOSED OF LOW RAIL PROPOSED TOP VARIES 13.83FT TO 42.56FT 14.00FT 2.00FT 1.00FT (MIN.) 14.00FT (TYP.) 2.00FT 1.00FT (MIN.) SUBBALLAST 6" 8.75FT 0.00FT TO 13.83FT VARIES 8.20FT TO 14.00FT VARIES 11.65FT TO 12.59FT VARIES (TYP.) 2.00FT 1.00FT (MIN.) SUBBALLAST 6" STEEL TIE (B Y O T H E R S ) S T A . 11 9 + 9 0 .4 0 S T A . 11 9 + 4 0 .0 0 T O T O B E R E M OV E D F R O M C / L E X I S T . S I D I N G T R A C K INCLUDED IN STAGE 1 ARE SHOWN IN BLACK. ALL PROPOSED CONSTRUCTION ELEMENTSNOTE: -TRK5- STA. 116+50.00 TO STA. 120+89.95 TRACKS (UNDER EXISTING I-277 BRIDGE) TYPICAL SECTION #1 - PROPOSED TRACK #5 SOUTHEAST OF EXISTING MAIN AND SIDING -TRK5- STA. 120+89.95 TO STA. 121+00.97 MAIN AND SIDING TRACKS TYPICAL SECTION #2 - PROPOSED TRACK #5 SOUTHEAST OF EXISTING WITH 7"X9"X8.5' TIMBER TIES 115# BALLASTED TRACK 1' (TYP.) 1' (TYP.) 2 RAILROAD TYPICAL SECTIONS STAGE 1 N O RTH CAR O LIN A P R OFESS I ON A L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 2-A RAILROAD TYPICAL SECTIONS (CONT'D) STAGE 1 N O RTH CARO LIN A P R OFESS I ON A L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 - A . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL 40:1 40:1 EXISTING GROUND EXISTING GROUND 2: 1 40:1 40:1 14.OOFT (MIN.) VARIES C /L P R O P . T R A C K # 5 (- T R K 5 -) C /L P R O P . T R A C K # 5 (- T R K 5 - ) -TRK5- STA. 121+00.97 TO STA. 121+69.87 TRACKS (UNDER WEST CARSON BOULEVARD) TYPICAL SECTION #3 - PROPOSED TRACK #5 SOUTHEAST OF EXISTING MAIN AND SIDING = 12" OUTSIDE OF CURVES SW = 6" FOR TANGENT TRACK & INSIDE OF CURVES (B Y O T H E R S ) C /L F U T U R E T R A C K 14.00FT (TYP) (T O R E M A I N ) C / L E X I S T . M A I N T R A C K (T O R E M A I N ) C / L E X I S T . M A I N T R A C K STA. 138+72.48 TO STA. 140+72.48 PRESENT FROM -TRK5- REQUESTED) (ADDITIONAL SURVEY CRASH PROTECTION WITH PROPOSED TO REMAIN BRIDGE COLUMN EXIST. CARSON BOULEVARD 8" ABC 8" ABC 8.50FT 8.50FT 8:1 -TRK5- STA. 138+72.48 TO STA. 140+72.48 -TRK5- STA. 121+69.87 TO STA. 121+89.95 TYPICAL SECTION #4 - NEW ROADBED FOR PROPOSED TRACK #5 STA. 138+72.48 STA. 139+60.48 PRESENT FROM -TRK5- 50:1 50:1 STA. 138+72.48 TO STA. 140+72.48 PRESENT FROM -TRK5- PROPOSED DETENTION POND 2: 1 2:1 2: 1 2:1 2:1 (MIN.) BALLAST 8" (MIN.) BALLAST 8" 50:1 ACCESS ROAD 10.00FT PROP. ACCESS ROAD 10.00FT PROP. LOW RAIL TOP OF PROPOSED GUTTER CURB AND CONCRETE 1.5FT 3.5" ASPHALT OF LOW RAIL PROPOSED TOP VARIES 11.27FT TO 34.53FT 14.00FT VARIES11.65FT TO 12.59FT VARIES SUBBALLAST 6" (TYP.) 2.00FT 1.00FT (MIN.) 18.50FT 2.00FT (MIN.) 2.00FT 1.00FT (MIN.) 18.50FT 1.00FT (MIN.) 2.00FT 25.00FT 6.00FT TO VARIES SUBBALLAST 6" 2 2 4 1 1 4 2 (TYP.) STEEL TIE STEEL TIE (B Y O T H E R S ) (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K FROM STA. 138+72.48 TO STA. 140+00.00 A PROPOSED STORMWATER ATTENUATOR 25.00FT DIMENSION CORESPONDS TO INCLUDED IN STAGE 1 ARE SHOWN IN BLACK. ALL PROPOSED CONSTRUCTION ELEMENTSNOTE: WALL HDPE (TYP.) 6" PERF SMOOTH 1' (TYP.) WITH BINDER 3.5" ASPHALT 1.5' 1' 6.5" 6" 6" 3"R CURB DETAIL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 2-B RAILROAD TYPICAL SECTIONS (CONT'D) STAGE 1 N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 - B . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL 40:1 40:1 EXISTING GROUND 2: 1 (MIN.) BALLAST 8" (MIN.) BALLAST 8" C /L P R O P . T R A C K # 5 (- T R K 5 -) T O S T A . 1 3 8 +7 2 .4 8 ) (P R E S E N T F R O M -T R K 5 - S T A . 1 2 1 + 8 9 .9 5 C /L P R O P . T R A C K # 6 (- T R K 6 - ) T O 1 2 9 + 1 9 .2 9 ) (P R E S E N T F R O M -T R K 5 - S T A . 1 2 3 + 2 5 .8 3 C /L P R O P . T R A C K # 7 (- T R K 7 - ) EXISTING GROUND -TRK5- STA. 121+89.95 TO STA. 138+72.48 TYPICAL SECTION #5 - NEW ROADBED FOR PROPOSED TRACKS #5, #6 AND #7 STA. 122+00.00 TO STA. 138+72.48 PRESENT FROM -TRK5- 8:1 8.50FT STA. 129+60.20 TO STA. 135+73.58 PRESENT FROM -TRK5- 50:1 50:1 STA. 137+05.19 TO STA. 138+72.48 PRESENT FROM -TRK5- PROPOSED DETENTION POND 2: 1 2:1 2:1 (MIN.) BALLAST 8" 50:1 ACCESS ROAD TO 36.00' PROP. VARIES 10.00FT OF LOW RAIL PROPOSED TOP OF LOW RAIL PROPOSED TOP OF LOW RAIL PROPOSED TOP 8" ABC (MIN.) 5.17FT 8.50FT ACCESS ROAD 10.00FT PROP. 1.5FT GUTTER CURB AND CONCRETE (MIN.) 5.17FT 16.50FT (TYP.) 0.00FT TO VARIES 23.00FT (TYP.) 0.00FT TO VARIES 3.5" ASPHALT 8" ABC 1.00FT (MIN.) 25.00FT 6.00FT TO VARIES 2.00FT BALLAST SUB- 6" SERVICE PLATFORM 12.67FT TOP OF RAIL TOP OF PLATFORM = TOP OF RAIL TOP OF PLATFORM = SUBBALLAST 6" 1.00FT (MIN.) 2.00FT (TYP.) 2.00FT 33.00FT 18.50FT TO VARIES 44.50FT 18.50FT TO VARIES ABC COMPACTED 6" (MIN.) 6" CONCRETE WALL HDPE (TYP.) 6" PERF SMOOTH 1 1 2 2 3 4 2 4 3 (TYP.) STEEL TIE INCLUDED IN STAGE 1 ARE SHOWN IN BLACK. ALL PROPOSED CONSTRUCTION ELEMENTSNOTE: FROM STA. 134+00.00 TO STA. 138+72.48 A PROPOSED STORMWATER ATTENUATOR 25.00FT DIMENSION CORESPONDS TO (TEMP. FROM STA. 130+00 TO 135+00) STA. 124+37.88 TO STA. 138+72.48 PRESENT FROM -TRK5- WITH BINDER 3.5" ASPHALT 1.5' 1' 6.5" 6" 6" 3"R CURB DETAIL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 - C . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL STAGE 2 EXISTING GROUND EXISTING GROUND 40:1 40:1 (MIN.) BALLAST 8" = 12" OUTSIDE OF CURVES SW = 6" FOR TANGENT TRACK & INSIDE OF CURVES = 12" OUTSIDE OF CURVES SW = 6" FOR TANGENT TRACK & INSIDE OF CURVES (B Y O T H E R S ) C /L F U T U R E T R A C K (B Y O T H E R S ) C /L F U T U R E T R A C K (T O R E M A I N ) C / L E X I S T . M A I N T R A C K (T O R E M A I N ) C / L E X I S T . M A I N T R A C K (T O R E M A I N ) C / L E X I S T . M A I N T R A C K (T O R E M A I N ) C / L E X I S T . M A I N T R A C K (MIN.) BALLAST 8" REQUESTED) (ADDITIONAL SURVEY CRASH PROTECTION WITH PROPOSED TO REMAIN BRIDGE COLUMN EXIST. I-277 40:12:12: 1 2:1 2: 1 2:1 2:1 2: 1 VARIES 13.83FT TO 42.56FT 14.OOFT (MIN.) VARIES 43.02FT TO 60.83FT 18.27FT TO 29.19FT VARIES 14.OOFT (MIN.) VARIES 40.85FT TO 43.02FT VARIES 29.19FT TO 41.74FT 14.00FT (TYP) 14.00FT (TYP) LOW RAIL TOP OF PROPOSED OF LOW RAIL PROPOSED TOP ( B Y N S R ) C /L P R O P . T R A C K # 5 (- T R K 5 -) S T A . 11 9 + 9 0 .4 0 ) (B Y N S R ) S T A . 11 9 + 6 6 .2 4 T O (T O B E R E M OV E D F R O M C / L E X I S T . S I D I N G T R A C K (B Y N S R ) C /L P R O P . T R A C K # 5 (- T R K 5 -) (T O B E R E M OV E D ) (B Y N S R ) C / L E X I S T . S I D I NG T R A C K SUBBALLAST 6" 8.20FT TO 14.00FT VARIES (TYP.) 2.00FT 1.00FT (MIN.) 14.50FT TO 19.23FT VARIES 0.00FT TO 13.83FT VARIES 8.75FT 14.00FT 14.00FT (TYP.) 2.00FT 1.00FT (MIN.)1.00FT (MIN.) SUBBALLAST 6" 2.00FT INCLUDED IN STAGE 2 ARE SHOWN IN BLACK. ALL PROPOSED CONSTRUCTION ELEMENTSNOTE: WITH 7"X9"X8.5' TIMBER TIES 115# BALLASTED TRACK 1' (TYP.) 1' (TYP.) BALLAST 8"MIN 6" SUBBALLAST STEEL TIE, M10 115#RE "e" CLIP HOOKED-IN SHOULDER DETAIL B BALLAST 8"MIN 6" SUBBALLAST STEEL TIE, M10 115#RE DETAIL A STEEL TIE DETAIL B 7"X9"X8.5' TIMBER TIE TIE PLATE DETAIL A -TRK5- STA. 116+50.00 TO STA. 120+89.95 TRACKS (UNDER EXISTING I-277 BRIDGE) TYPICAL SECTION #1 - PROPOSED TRACK #5 SOUTHEAST OF EXISTING MAIN AND SIDING -TRK5- STA. 119+90.40 TO STA. 120+89.95 MAIN AND SIDING TRACKS TYPICAL SECTION #2 - PROPOSED TRACK #5 SOUTHEAST OF EXISTING RAILROAD TYPICAL SECTIONS (CONT'D) 2-C STAGE 2 N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 2-D RAILROAD TYPICAL SECTIONS (CONT'D) STAGE 2 N O RTH CAR O LIN A P R OFESS I ON A L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 - D . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL 40:1 40:1 EXISTING GROUND EXISTING GROUND 2: 1 (MIN.) BALLAST 8" 40:1 40:1 (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K (MIN.) BALLAST 8" C /L P R O P . T R A C K # 5 (- T R K 5 -) C /L P R O P . T R A C K # 5 (- T R K 5 - ) -TRK5- STA. 121+00.97 TO STA. 121+69.87 TRACKS (UNDER WEST CARSON BOULEVARD) TYPICAL SECTION #3 - PROPOSED TRACK #5 SOUTHEAST OF EXISTING MAIN AND SIDING = 12" OUTSIDE OF CURVES SW = 6" FOR TANGENT TRACK & INSIDE OF CURVES (B Y O T H E R S ) C /L F U T U R E T R A C K (T O R E M A I N ) C / L E X I S T . M A I N T R A C K (T O R E M A I N ) C / L E X I S T . M A I N T R A C K STA. 138+72.48 TO STA. 140+72.48 PRESENT FROM -TRK5- REQUESTED) (ADDITIONAL SURVEY CRASH PROTECTION WITH PROPOSED TO REMAIN BRIDGE COLUMN EXIST. CARSON BOULEVARD 8.50FT 8.50FT 8:1 -TRK5- STA. 138+72.48 TO STA. 140+72.48 -TRK5- STA. 121+69.87 TO STA. 121+89.95 TYPICAL SECTION #4 - NEW ROADBED FOR PROPOSED TRACK #5 STA. 138+72.48 STA. 139+60.48 PRESENT FROM -TRK5- 50:1 50:1 STA. 138+72.48 TO STA. 140+72.48 PRESENT FROM -TRK5- PROPOSED DETENTION POND 2: 1 2:1 2: 1 2:1 2:1 VARIES 14.OOFT (MIN.) VARIES 14.00FT (TYP) OF LOW RAIL PROPOSED TOP LOW RAIL TOP OF PROPOSED 8" ABC 3.5" ASPHALT 8" ABC 50:1 1.00FT (MIN.) ACCESS ROAD 10.00FT PROP. ACCESS ROAD 10.00FT PROP. GUTTER CURB AND CONCRETE (TYP.) 2.00FT 1.00FT (MIN.) 14.00FT VARIES 11.27FT TO 34.53FT11.65FT TO 12.59FT VARIES SUBBALLAST 6" 18.50FT 18.50FT 2.00FT (MIN.) 2.00FT 1.00FT (MIN.) 1.5FT 2.00FT 25.00FT 6.00FT TO VARIES SUBBALLAST 6" WALL HDPE (TYP.) 6" PERF SMOOTH 2 2 4 42 1 1 STEEL TIE STEEL TIE INCLUDED IN STAGE 2 ARE SHOWN IN BLACK. ALL PROPOSED CONSTRUCTION ELEMENTSNOTE: FROM STA. 138+72.48 TO STA. 140+00.00 A PROPOSED STORMWATER ATTENUATOR 25.00FT DIMENSION CORESPONDS TO 1' (TYP.) WITH BINDER 3.5" ASPHALT 1.5' 1' 6.5" 6" 6" 3"R CURB DETAIL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 2-E RAILROAD TYPICAL SECTIONS (CONT'D) STAGE 2 N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 - E . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL 40:1 40:1 EXISTING GROUND 2: 1 (MIN.) BALLAST 8" (MIN.) BALLAST 8" C /L P R O P . T R A C K # 5 (- T R K 5 -) T O S T A . 1 3 8 +7 2 .4 8 ) (P R E S E N T F R O M -T R K 5 - S T A . 1 2 1 + 8 9 .9 5 C /L P R O P . T R A C K # 6 (- T R K 6 - ) T O 1 2 9 + 1 9 .2 9 ) (P R E S E N T F R O M -T R K 5 - S T A . 1 2 3 + 2 5 .8 3 C /L P R O P . T R A C K # 7 (- T R K 7 - ) EXISTING GROUND -TRK5- STA. 121+89.95 TO STA. 138+72.48 TYPICAL SECTION #5 - NEW ROADBED FOR PROPOSED TRACKS #5, #6 AND #7 STA. 122+00.00 TO STA. 138+72.48 PRESENT FROM -TRK5- STA. 124+37.88 TO STA. 138+72.48 PRESENT FROM -TRK5- 8:1 8.50FT STA. 129+60.20 TO STA. 135+73.58 PRESENT FROM -TRK5- 50:1 50:1 STA. 137+05.19 TO STA. 138+72.48 PRESENT FROM -TRK5- PROPOSED DETENTION POND 2: 1 2:1 2:1 ABC COMPACTED 6" (MIN.) OF LOW RAIL PROPOSED TOP OF LOW RAIL PROPOSED TOP OF LOW RAIL PROPOSED TOP 6" CONCRETE 8" ABC 8" ABC 3.5" ASPHALT (MIN.) BALLAST 8" 50:1 ACCESS ROAD TO 36.00' PROP. VARIES 10.00FT 2.00FT31.00FT 18.50FT TO VARIES SUBBALLAST 6" SERVICE PLATFORM 12.67FT BALLAST SUB- 6" 44.50FT 18.50FT TO VARIES GUTTER CURB AND CONCRETE 2.00FT 25.00FT 6.00FT TO VARIES 1.00FT (MIN.) 1.5FT 1.00FT (MIN.) (TYP.) 2.00FT (MIN.) 5.17FT (MIN.) 5.17FT TOP OF RAIL TOP OF PLATFORM = TOP OF RAIL TOP OF PLATFORM = 16.50FT (TYP.) 0.00FT TO VARIES 23.00FT (TYP.) 0.00FT TO VARIES 8.50FT ACCESS ROAD 10.00FT PROP. WALL HDPE (TYP.) 6" PERF SMOOTH 2 2 1 1 2 3 4 3 4 (TYP.) STEEL TIE INCLUDED IN STAGE 2 ARE SHOWN IN BLACK. ALL PROPOSED CONSTRUCTION ELEMENTSNOTE: FROM STA. 134+00.00 TO STA. 138+72.48 A PROPOSED STORMWATER ATTENUATOR 25.00FT DIMENSION CORESPONDS TO WITH BINDER 3.5" ASPHALT 1.5' 1' 6.5" 6" 6" 3"R CURB DETAIL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 CENTER OF CURVE CS SC TS X SPI Y L R s s c I sLs L PTPCRR L TS ST I SC CS s c s CENTER OF CURVE CENTER OF CURVE SPIRAL TRANSITION CURVES CIRCULAR CURVE WITH SIMPLE CIRCULAR CURVE SPIRAL TRANSITION CURVE RADIUS OF CURVATURE DEGREE OF CURVATURE (CHORD DEFINED) LENGTH OF CURVE (CHORD DEFINED) TOTAL INTERSECTION ANGLE CURVE ANGLE SPIRAL ANGLE SPIRAL DEFLECTION LENGTH OF SPIRAL SPIRAL TANGENT LENGTH TO OFFSET SPIRAL TANGENT OFFSET POINT OF INTERSECTION (CIRCULAR CURVE) POINT OF INTERSECTION (TANGENT) POINT OF INTERSECTION (SPIRAL) TANGENT TO CIRCULAR CURVE CIRCULAR CURVE TO TANGENT TANGENT TO SPIRAL CIRCULAR CURVE TO SPIRAL SPIRAL TO CIRCULAR CURVE SPIRAL TO TANGENT R L I X Y PC SPI PT TS SC CS ST Ls s s c Dc 0 0 FIGURE A FIGURE B FIGURE C FIGURE D PINCPOL POL PINC POINT OF INTERSECTION NO CURVE DEFLECTION BETWEEN TANGENTS BEARING 1 BEARING 2 I =c c tPI = PI PIt PIc cPI tPI HORIZONTAL CURVE GEOMETRY 2-F 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 - F . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 2-G PROPOSED YARD TRACK #5 GEOMETRY 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 - G . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 2-H PROPOSED YARD TRACKS #6 & #7 GEOMETRY 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 - H . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL PARCEL INDEX PROPERTY OWNER SUMMARY LEGEND MARCH 2016 ACQUISITION OCTOBER 2016 ACQUISITION JANUARY 2017 ACQUISITION 32A 32 26 20B 20A 21D 28 1 31B 31 31D 31C31F 35 33 31E 31A EXIST. RAILROAD ROW 3 10' ALLEY CITY O F CHARLOTTE 1 5' SANITARY SEWER EASEMENT DEE D BOOK 129 0, PAG E 333 W E S T P A L M E R S T R E E T C L O S E D 0 8 / 2 8 / 1 9 8 9 R E S. B K. 2 5, P G. 3 4 8 D E E D B K. 6 1 6 1 , P G. 8 1 2 10' ALLEY DEED BOOK 1801, PAGE 184 1 2 9 0 , P A G E 4 0 0 D E E D B O O K 40' PUBLIC R/W (C.O.C.) 5 0 ' P U B L I C R I G H T O F W A Y ( C . O . C . ) H & S ROOFING CO. 3 5 ' P U B L I C R I G H T O F W A Y ( C . O . C . ) DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-A GRAND TOTAL WASTE IN LIEU OF BORROW LENGTH STRAIGHT BEG. STA.END STA.LOCATION TOTAL: TOTAL ANCHOR LENGTH: TOTAL GUARDRAIL LENGTH: SAY: GUARDRAIL SUMMARY WARRANT POINT FLARE LENGTH W*ANCHORS REMARKS M-350 BICCAT-1 AT-1 TYPE 350 ATTENUATOR IMPACT GUARDRAIL EXISTING REMOVE GUARDRAIL EXISTING STOCKPILE AND REMOVE EA NG B-77 TYPE III CHAIN SIDESTATION - STATION AREA (SY) BARRIER CONCRETE FACED SINGLE LINE SURVEY WIDTH SHOUL. TOTAL E.O.L. FROM DIST. "N" CURVED SHOP FACED DOUBLE END APPROACH END TRAILING END APPROACH MOD XI END TRAILING END APPROACH END TRAILING 350 GRAU MOD VI NG = NON-GATING IMPACT ATTENUATOR TYPE 350 G = GATING IMPACT ATTENUATOR TYPE 350 W = TOTAL WIDTH OF FLARE FROM BEGINNING OF TAPER TO END OF GUARDRAIL. FLARE LENGTH = DISTANCE FROM LAST SECTION OF PARALLEL GUARDRAIL TO END OF GUARDRAIL. TOTAL SHOULDER WIDTH = DISTANCE FROM EDGE OF TRAVEL LANE TO SHOULDER BREAK POINT. "N" = DISTANCE FROM EDGE OF LANE TO FACE OF GUARDRAIL. * W MEASURED FROM "N" AT THE BEGINNING OF THE ANCHOR TO "N" AT THE END OF THE ANCHOR. G ADDITIONAL GUARDRAIL POST 5 EACH DEDUCTIONS TOTAL GRAU 350 @ ANCHOR TOTAL DEDUCTIONS = (IN CUBIC YARDS) SUMMARY OF EARTHWORK @AT-1 6.25 50.00 LOCATION WASTEBORROWUNDERCUTSIDECHAINEMBT+% STATION FROM STATION TO EXCAVATION UNCL. TOTAL : SAY : TOTAL 140+72.48 136+50.00 140+72.48 65,791 49,291 3,956 65,423 65,423 49,291 END SECTION TERMINAL TES X X RT & LT RT & LT RT & LT RT & LT 11,300 37.5 0 2 658 682 50 SUMMARY OF QUANTITIES 2 REDUCTION OF UNCLASSIFIED EXCAVATION LOSS DUE TO CLEARING AND GRUBBING LT & RT LT & RT RT PENMAN STREET LT LT 75 62.5 187.5 EXIST. GUARDRAIL EXIST. GUARDRAIL EXIST. GUARDRAIL -TRK5- -TRK5- -TRK5- -TRK5- -TRK5- -TRK5- -TRK5- -TRK5- -TRK5- -TRK5- ASPHALT PAVEMENT REMOVAL SUMMARY CHAIN SIDESTATION - STATION AREA (SY)LOCATION TOTAL : SAY : RT & LT RT & LT 5,900 288-TRK5- -TRK5- CONCRETE PAVEMENT REMOVAL SUMMARY STREET PALMER STREET PENMAN PARKING LOT PARKING LOT PARKING LOT PARKING LOT 128+62 128+98 124+61 124+99 125+65 126+31 129+26 129+84 131+49 - 132+42 136+41 - 139+24 5,528 5,816 1,065 8,857 130+96 - 132+51 134+64 - 139+92 11,262 129+08 - 129+51 125+07 - 125+37 116+50.00 115,082 368 368 45,703 45,703 111,126 STAGE 2 SUBTOTAL SUMMARY NO. 1 STAGE 1 SUBTOTAL SUMMARY NO. 1 37.5 37.5 37.5 SEE STAFF BUILDING/ARCHITECTUAL PLANS SUMMARY OF QUANTITIES FOR ADDITIONAL DETAILS. NOTE: 65,791 3,588 3,588 115,082 3,956 111,126 APPROXIMATION 116,000 4,000 112,000 LOCATIONDESCRIPTION NEW TRACK CONST. (TIMBER TIES) NEW TRACK CONST. (STEEL TIES) DERAIL (BLUE FLAG) WITH LIGHT STONE BALLAST (FURNISH AND PLACE) SUB-BALLAST (FURNISH AND PLACE) ASPHALT CROSSING WITH RUBBER FLANGEWAY FILLER 115# RE No.10 LH TURNOUT WITH STEEL TIES 115# RE No.10 RH TURNOUT WITH STEEL TIES SWITCH POINT DERAIL BUMPING POST (TYPE WK) QUANTITY 290 3,810 2,400 3,000 96 1 2 5 1 2 EA EA EA EA EA TF TF TN TN EA TRACKWORK QUANTITIES 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - A . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-B DRAINAGE SUMMARY N O RTH CARO LIN A P R OFESS I ON A L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL 3 / 4 / 2 0 1 6 I : \ V o l 3 \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - B . d g n j o s h i p r PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. DocuSign Envelope ID: 2C49F13A-7049-4347-B41F-0AF13BBBEBC4 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-C SPECIAL TRACKWORK DETAILS DERAIL DETAIL 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - C . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-D CROSSSING DETAILS (EQUIVALENT SUBSTITUTE MAY BE APPROVED BY ENGINEER) 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - D . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 16 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - E . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DI C B C B CB C B C B C B C B G A S LI N E L O C A TI O N P E R FI E L D M A R KI N G S 5 4 " W A T E R L I N E O U T SI D E R/ W 2 0 ' M B S L ( T Y P I C A L ) S S S S S B UIL DI N G ( T Y PI C A L) DI C B C B 2X ELM BRUSH S-M HARDWOODS BRUSH BRUSH BRUSH BRUSH BRUSH BRUSH BRUSH HARDWOODS SMALL - MEDIUMHARDWOODS BRUSH SMALLHARDWOODS S-MHARDWOODS BRUSHSMALL HARDWOODS BRUSH BRUSH S-M HARDWOODS AND BRUSH S-M HARDWOODS AND BRUSH BRUSH BRUSH S-M CONIFERS BRUSH S-M HARDWOODS BRUSH BRUSH S-MHARDWOODS S-M HARDWOODS 2X ELM BRUSH S-M HARDWOODS BRUSH BRUSH BRUSH BRUSH BRUSH BRUSH BRUSH HARDWOODS SMALL - MEDIUMHARDWOODS BRUSH SMALLHARDWOODS S-MHARDWOODS BRUSHSMALL HARDWOODS BRUSH BRUSH S-M HARDWOODS AND BRUSH S-M HARDWOODS AND BRUSH BRUSH BRUSH S-M CONIFERS BRUSH S-M HARDWOODS BRUSH BRUSH S-MHARDWOODS S-M HARDWOODS CONC. SLAB CO NC. SLAB C O NC. P A D CONC. PAD CONC.DRIVE/SLOPE PROTECTION SLOPE PROTECTION SLOPE PROTECTION SLOPE PROTE CTION SLOPE PROTECTION SLOPEPROTECTION SLOPE PROTECTION SLOPEPROTECTIO N SLOPEPROTECTIO N SLOPEPROTECTION CON C.SLAB SWSW SW 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 6' C H A IN L I N K F E N C E 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 5' D EC O R A T I VE M E T A L F E N CE 5' DE C O R A TIV E M E T A L FEN C E E N D F E N C E G U A R D P OS T S E VER Y 4' 5' CHAIN LINK FENCE WOOD FENCE 6' CHAIN LIN K FENCE 6' CHAIN LINK FENCE CB C B C B C B C B DI DI C B C B DI DI DI DI S S W V G V W M W M S S W M W M W M W M W M W M W M W M W M W M W M M M W V W V W M W V W V W V W M S S W M D S W V W V S G V W M W V D S S WV D GV S D D D W V W M W V W M S W M S W M W M S WV WV G V W V G V S D GVWV W V G V G M DWV WV W V S S W M W V WV G M W V GV G V WV S D WM WM S WV WVWV WM GVWM S W V W M W V WV D WM GV WM WM WM WV S WV WM WM WM WM WV W V WM WM CONC CO NC D S T R E E T W E S T M O R E H E A D W E S T S U M M I T A V E . TO CONCORD CONTRACTOR) REMOVED (BY NCDOT PAVEMENT TO BE EXISTING CONCRETE CONTRACTOR) (BY NCDOT TO BE REMOVED EXISTING SHED CONTRACTOR) (BY NCDOT TO BE REMOVED EXISTING FENCE CONTRACTOR) (BY NCDOT IN JANUARY 2017 OF RIGHT-OF-WAY UPON AQUISITION TO BE REMOVED EXISTING BUILDING CONTRACTOR) (BY NCDOT IN JANUARY 2017 OF RIGHT-OF-WAY UPON AQUISITION TO BE REMOVED EXISTING BUILDING FREE WA Y WEST JO H N BELK INTERSTATE 27 7 C A R S O N B L V D P A L M E R S T R E E T P E N M A N S T R E E T GRAHAM STREET W I N O N A S T R E E T CONTRACTOR) REMOVED (BY NCDOT PAVEMENT TO BE EXISTING ASPHALT TO REMAIN EXISTING BUILDING TO REMAIN EXISTING BUILDING TO REMAIN BUILDINGS EXISTING BRIDGE PIER TO REMAIN OF EXISTING ROADWAY APPROXIMATE LOCATION TO REMAIN SIDING TRACK EXISTING ROADWAY BRIDGE PIERS TO REMAIN APPROXIMATE LOCATION OF EXISTING TO REMAIN EXISTING MAIN TRACKS CONTRACTOR) (BY NCDOT TO BE REMOVED EXISTING FENCE CONTRACTOR) (BY NCDOT TO BE REMOVED EXISTING FENCE CONTRACTOR) REMOVED (BY NCDOT PADS TO BE EXISTING CONCRETE CONTRACTOR) (BY NCDOT TO BE REMOVED EXISTING BUILDING TO REMAIN EXISTING FENCE CONTRACTOR) (BY NCDOT IN OCTOBER 2016 OF RIGHT-OF-WAY UPON AQUISITION TO BE REMOVED EXISTING BUILDING TO REMAIN EXISTING MAIN TRACKS T O G A S T O N I A CONTRACTOR) REMOVED (BY NCDOT PAVEMENT TO BE EXISTING ASPHALT CONTRACTOR) (BY NCDOT REMOVED TO BE PAVEMENT ASPHALT EXISTING TO HAVE TOP 4' REMOVED EXISTING RETAINING WALL S T A . 1 1 6 + 5 0 P . S . S T A . 1 2 3 + 1 2 . 4 6 N.I.C TRACK (BY NSR) REPLACED WITH PANEL BE REMOVED AND EXISTING TURNOUT TO N.I.C. (BY NSR) REMOVED TRACK TO BE EXISTING SIDING N.I.C. SEE SCO# 100863403 DEMO FOR MAINTENANCE FACILITY 4 3-E 0 PLANS 100 20010050 SITE DEMOLITION PLAN LEGEND (BY NSR) PROPOSED CONSTRUCTION (NCDOT CONTRACTOR) PROPOSED ASPHALT REMOVAL (NCDOT CONTRACTOR) PROPOSED CONCRETE REMOVAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-F (EQUIVALENT SUBSTITUTE MAY BE APPROVED BY ENGINEER) #10 STEEL TIE TURNOUT 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - F . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-H (EQUIVALENT SUBSTITUTE MAY BE APPROVED BY ENGINEER) STEEL TIE 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - H . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-I (EQUIVALENT SUBSTITUTE MAY BE APPROVED BY ENGINEER) BUMPING POST (TYPE WK) 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - I . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-J DRIVEWAY TURNOUT 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - J . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-K MEDIAN CURB FOR CATCH BASIN 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - K . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-L CONCRETE CATCH BASIN 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - L . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-M CONCRETE CATCH BASIN 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - M . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 4 _ 1 A . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL 5 4 " W A T E R L I N E S S S BRUSH BRUSH BRUSH SMALLHARDWOODS S-M HARDWOODS BRUSH SMALL HARDWOODS BRUSH BRUSH S-M HARDWOODS AND BRUSH S-M HARDWOODS AND BRUSH BRUSH BRUSH S-M CONIFERS BRUSH S-M HARDWOODS BRUSH BRUSH S-M HARDWOODS BRUSH BRUSH BRUSH SMALLHARDWOODS S-M HARDWOODS BRUSH SMALL HARDWOODS BRUSH BRUSH S-M HARDWOODS AND BRUSH S-M HARDWOODS AND BRUSH BRUSH BRUSH S-M CONIFERS BRUSH S-M HARDWOODS BRUSH BRUSH S-M HARDWOODS C O N C . P A D CONC. PAD CONC.DRIVE/SLOPE PROTECTION SLOPE PROTECTION SLOPE PROTECTION SLOPE PROTECTION SLOPEPROTECTION SLOPEPROTECTION SLOPE PROTECTION SLOPEPROTECTION SLOPEPROTECTION SLOPEPROTECTION CONC.SLAB SW 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 5 ' D E C O R A T I V E M E T A L F E N C E 5 ' D E C O R A T I V E M E T A L F E N C E E N D F E N C E G U A R D P O S T S E V E R Y 4 ' WOOD FENCE G V W V G V S G M GV G V D WM GVWM S W V W M W V WVD WM GV WM WM WM WV S WV WM WM WM WM WV W V WM WM CONC CONC 10' ALLEY W E S T P A L M E R S T R E E T C L O S E D 0 8 / 2 8 / 1 9 8 9 R E S . B K . 2 5 , P G . 3 4 8 D E E D B K . 6 1 6 1 , P G . 8 1 2 VARIABLE WIDTH PUBLIC R/W 10' ALLEY S 3 9 ° 2 1 ' 5 3 " E 2 5 7 . 9 6 ' S 50° 52' 49" W 163.71' S 50° 31' 46" W 185.69' S 50° 28' 25" W 250.70' N 3 9 ° 2 7 ' 1 1 " W 1 5 4 . 2 9 ' N 50° 51' 13" E 251.44' S 3 9 ° 0 1 ' 5 7 " E 1 4 3 . 0 0 ' N 39° 18' 04" W 154.17' N 39° 21' 53" W 100.49'S 61° 47' 31" E107.65' S 33° 34' 04" E88.34' 5 0 ' P U B L I C R I G H T O F W A Y ( C . O . C . ) 3 5 ' P U B L I C R I G H T O F W A Y ( C . O . C . ) EXISTING RAILROAD R/W EXISTING RAILROAD R/W DEPARTMENT OF TRANSPORTATION T R A N S P O R T A T I O N D E P A R T M E N T O F CARSON BOULEVARD 0WNED BY NCDOT 28 1 P A R C E L # 0 7 3 2 6 2 2 0 PARCEL #07326803 DEPARTMENT OF TRANSPORTATION PARCEL #07326226 20A 21D 20B 31A #07326804 PARCEL TRANSPORTATION DEPARTMENT OF PARCEL #07326219 TRANSPORTATION DEPARTMENT OF C C C C C C G V GV LS R E M F H PF H 1 0 +0 0 1 0 + 0 0 1 1 + 0 0 1 2 + 0 0 0+00 1 + 0 0 2 + 0 0 LS 1 6 + 0 0 S S C O 1 2 + 0 0 1 3 + 0 0 1 3 + 0 0 1 4 + 0 0 1 5 + 0 0 1 7 + 0 0 3 + 0 0 4 + 0 0 5 + 0 0 4" PVC S/LCO 700.94 -TRK7- -TRK6- 1 2 5 -TRK5- CURVE TRK 7 - 1 CURV E TRK 6 - 1 CURVE TRK 5 - 2 P C S t a . 1 2 4 + 2 7 . 4 5 P T S t a . 12 7 + 14 .63 1 5' 5 9. 7 " W P T S t a . 12 7 + 2 1 .4 0 P T S t a . 12 7 + 10 .14 1 2 4 + 7 9 . 1 6 P C S t a . S t a . 1 2 4 + 6 5 . 5 6 - T R K 6 - P C P I P R O P . N o . 1 0 R B M R H T O - T R K 7 - P I / T O S t a . 1 2 3 + 5 7 . 6 0 - T R K 6 - P I / T O S t a . 1 2 3 + 5 7 . 6 0 = P R O P . T R A C K # 7 B E G I N T R A C K C O N S T . P S P R O P . N o . 1 0 R B M R H T O - T R K 7 - P S S t a . 1 2 3 + 2 6 . 3 5 - T R K 6 - P S S t a . 1 2 3 + 2 6 . 3 5 = C O N T R A C T O R ) Y A R D B A L L A S T ( B Y N C D O T B E G I N C O N S T R U C T I O N A N D N O R M A L B A L L A S T ( B Y N S R ) E N D C O N S T R U C I T O N A N D S T A . 1 2 3 + 1 3 . 3 9 (TO REMAIN) EXIST. MAIN TRACKS T O GA S T ON IA P A L M E R S T R E E T 3 5 ' P U B L I C R / W S T R E E T W E S T M O R E H E A D J O H N B E L K F R E E W A Y W ES T IN T E R S T A T E 277 APPROX. 1,400' TO MP 378 P U B L I C R / W C A R S O N B L V D PROP. TRACK #6 PROP. TRACK #7 PROP. TRACK #5 (TO REMAIN) TRACK EXIST. SIDING (BY OTHERS) PROP. FUTURE TRACK TO CONCORD GRAHAM STREET 40' PUBLIC R/W THRU U-9) (SEE SHTS U-1 WATER LINE RELOC. S-1 THRU S-6) (SEE SHEETS (TO REMAIN) BRIDGE PIER OF EXIST. ROADWAY APPROX. LOCATION (SEE SHTS U1 THRU U9) RELOC. 54" WATER LINE FOR DETAILS) A-1 AND A-2 (SEE SHEETS PROP. FACILITY 1 6 .5 ' 23 ' 3 1 5' C L E A R P O I N T 1 5 ' C L E A R P O I N T TES TES GUARDRAIL MARKERS WITH OF ROAD INSTALL END 1 1 1. 6 5 ' ( M I N . ) POINT 10' CLEAR 14.50' (MIN.) 1 2 5 ' 7 5 ' 44.5000 +62.80 44.5000 +03.30 18.5000 +36.80 18.5000 +29.24 S T A . 1 2 4 + 3 3 . 7 4 S T A . 1 2 2 + 0 0 . 0 0 102.99 +07.8086.64 +66.33 129.91 +77.66 123.60 +03.66 271.56 +53.25 64.53 +39.45 NEW 115# BALLASTED TRACK WITH TIBER CROSS TIES (SEE SHEETS S-1 THRU S-6) BRIDGE PIERS (TO REMAIN AND REENFORCED) APPROX. LOCATION OF EXIST. ROADWAY STEEL CROSS TIESTRACK WITHNEW 115# BALLAST 10' ACCESS ROAD 10' ACCESS ROAD 20.26 +13.39 26.72 +77.56 19.50 +00.00 OR RAILS TO MATCH EXISTING RAIL WEIGHT CONTRACTOR SHAL PROVIDE COMPROMISE JOINTS PROP. 115# SWITCH POINT DERAIL, S T A . 12 7 + 21 .40 T R A C K 7 W I T H L I GH T B L U E F L AG D E R A I L S T A . 12 7 +9 7 .31 T R A C K 6 W I T H L I GH T B L U E F L AG D E R A I L T R A C K 5 S T A . 1 28 + 1 0 .2 0 W I T H L I G H T B L U E F L A G D E R A I L ASPHALT WALKWAY 12'X22' DUMPSTER PAD, 4 M A T C H L I N E P R O P . T R A C K # 5 S T A . 12 8 +00 S EE S H EE T 5 RESPECTIVELY 5, 6, &7 PROFILES, FOR PROP. TRACKS SEE SHEETS 7 THRU 9 BE ACQUIRED BY NCDOT PARCEL 31A (CP&F) WILL STA. 116+50.00 TO STA. 128+00.00 PLAN -TRK5 -TRK5- 1 1 5 P T S t a . 1 2 0 + 8 9 . 9 5 T I E T O E X I S T . S I D I N G T R A C K P R O P . T R A C K # 5 B E G I N T R A C K S H I F T P O T S t a . 1 1 6 + 5 0 . 0 0 POT Sta. 114+91.57 CURVE TRK5-1 1 2 0 P I P R O P . N o . 1 0 R B M R H T O - T R K 6 - P I / T O S t a . 1 2 2 + 2 1 . 2 0 - T R K 5 - P I / T O S t a . 1 2 2 + 2 1 . 2 0 = P R O P . T R A C K # 6 B E G I N T R A C K C O N S T . P S P R O P . N o . 1 0 R B M R H T O - T R K 6 - P S S t a . 1 2 1 + 8 9 . 9 5 - T R K 5 - P S S t a . 1 2 1 + 8 9 . 9 5 = B E G I N T R A C K R E M O V A L P R O P . T R A C K # 5 B E G I N T R A C K C O N S T . E N D T R A C K S H I F T P C S t a . 1 1 9 + 4 0 . 0 0 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 5 _ 1 A . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL D I CB C B CB C B C B C B C B GA S L I N E L O C A T IO N P E R F I E L D M A R K ING S 2 0 ' M B S L ( T Y P I C A L ) S S B U I L D I N G ( T Y P I C A L ) D I C B CB 2X ELM BRUSH S-M HARDWOODS BRUSH BRUSH BRUSH BRUSH BRUSH HARDWOODS SMALL - MEDIUM HARDWOODS 2X ELM BRUSH S-M HARDWOODS BRUSH BRUSH BRUSH BRUSH BRUSH HARDWOODS SMALL - MEDIUM HARDWOODS CONC. SLAB CONC. SLAB SWSW 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 6' CHAIN LINK FENCE 6' C H A IN LI N K F E N C E C B C B C B D I D I C B D I D I D I D I S S W V G V W M W M S S W M W V W V W MW V W V W V W M S S W M D S W V W V S GV W M W V D S S WV D GV S D D D W V W M W V S W M S W M W M S WV WV S D GVWV D WV WV W V S WV WV WM WVWV WV WM D CITY OF CHARLOTTE 15 ' SANITARY SEWER EASEMENT DEED BOOK 1290 , PAGE 333 CHARLOTTE PIPE AND CHARLOTTE PIPE AND CHARLOTTE PIPE AND DEED BOOK 9183, PAGE 203 PARCEL #07326232 N 3 4 ° 0 9 ' 1 5 " W 9 9. 9 2' ( T I E ) N 3 4 ° 1 7 ' 2 0 " W 1 5 0 . 2 2' ( T I E ) N 3 4 ° 13' 47 " W 2 4. 9 3' (TIE) S 3 4 ° 0 6 ' 5 3 " E 4 0 2 . 0 2 ' N 3 9 ° 3 3' 2 2 " W 2 1 9 . 0 3' N 39 ° 3 3' 2 2 " W 1 02. 9 4' S 5 0 ° 1 8' 5 7 " W 139 . 9 6' S 39 ° 2 8' 3 8 " E 8 9. 2 0' S 52° 37' 48" W 238.93' S 56° 20' 27" W 396.45' N 3 0 ° 3 3 ' 4 0 " W 3 4 6 . 4 2 ' S 3 0 ° 1 9 ' 4 0 " E 1 3 8 . 6 2 ' N 3 4 ° 0 9 ' 4 5 " W 2 0 4 . 5 4' N 34 ° 27' 1 0 " W 1 1 3 . 8 7' N 38° 11' 53" E 199.79' N 38° 11' 53" E223.83' 1 3 3 . 4 0' S 3 0 ° 4 1 ' 0 5 " E 3 3 0 . 0 7' S 3 0 ° 4 1' 0 5 " E N 55° 53' 40" E 195.14' S 55° 49' 30" W 195.06' N 55° 53' 56" E194.56' N 3 3 ° 5 9 ' 2 7 " W 1 0 9 . 7 3 ' DEED BOOK 1801, PAGE 184 C H A R L O T T E P I P E A N D N 3 4 ° 1 0 ' 2 5 " W 1 1 0 . 0 0 ' N 3 4 ° 0 6' 5 3 " W 1 5 4 . 2 6 ' N 55° 56' 22" E195.82' S 55° 56' 22" W 195.68' 3 9 9 . 1 5' S 3 9 ° 0 6' 2 7 " E 1 2 9 0 , P A G E 4 0 0 D E E D B O O K 2 4 9 . 9 4 ' N 3 4 ° 0 9 ' 4 5 " W 40' PUBLIC R/W (C.O.C.) 5 0 ' P U B L I C R I G H T O F W A Y ( C. O. C.) H & S ROOFING CO. INDUSTRIES WHITE CONSOLIDATED EXISTING RAILROAD R /W EXISTING RAILROAD R/W 33 FOUNDRY COMPANY F O U N D R Y C O M P A N Y CHARLOTTE PIPE & FOUNDRY CO. FOUNDRY COMPANY RJS/STS LLC DEPARTMENT OF TRANSPORTATION PARCEL #07326218 T R A N S P O R T A TI O N D E P A R T M E N T O F HAL H. CONROY FOUNDRY COMPANY WHITE CONSOLIDATED INDUSTRIES 35 26 DEPARTMENT OF TRANSPORTATION PARCEL #07326220 P A R C E L # 0 7 3 2 6 2 2 0 PARCEL #07326217 PARCEL #07326216 PARCEL #07326203 PARCEL #07326207 PARCEL #11910318 PARCEL #11910398 P A R C E L # 0 7 3 2 6 2 0 1 PARCEL #07326230 PARCEL #07326215 20B 20A BASCOM V. BELK PARCEL #07326214 CHARLOTTE PIPE AND FOUNDRY COMPANY PARCEL #07326215 31B 31D 31E RJS/STS LLC PARCEL #07326216 32A CHARLOTTE PIPE AND FOUNDRY COMPANY PARCEL #07326203 31C 31 32 31F C C PF H 0 + 0 0 0 + 0 0 10+00 11+00 0+00 2+00 2 + 0 0 1+00 3+00 4+00 TGV PWM PRPZ 12+00 14+00 15+00 16+00 TRK6-2 CURVE -TRK5- 1 4 0 P T S t a . 1 3 6 + 3 7 . 0 2 15' 59.7" W P R O P . T R A C K # 5 B E G I N R D B E D . C O N S T . - T R K 5 - P O T S t a . 1 3 6 + 0 0 . 0 0 P R O P . T R A C K # 5 E N D T R A C K C O N S T . E N D R D B E D . C O N S T . P O T S t a . 1 4 0 + 7 2 . 4 8 P I P R O P . N o . 10 RB M L H T O -T R K 6 - P I /T O S t a . 138 +2 9 .3 7 -T R K 5 - P I /T O S t a . 13 8 +41 .23 = P R O P . T R A C K #6 E N D T R A C K C ON S T . P S P R O P . N o . 10 R B M L H T O -T R K 6 - P S S t a . 13 8 +6 0 .62 -T R K 5 - P S S t a . 138 +72 .48 = -TRK7-15' 59.7" W -TRK6- 1 3 0 -TRK5- 1 3 5 P R O P . T R A C K # 6 B E G I N R D B E D . C O N S T . - T R K 6 - P O C S t a . 1 3 5 + 8 7 . 0 9 - T R K 6 - P C S t a . 1 3 5 + 6 0 . 6 9 (TO REMAIN) EXIST. MAIN TRACKS TO GA STON IA 6 0 ' P U B L I C R / W P E N M A N S T R E E T 5 0' P U B LI C R/ W W E S T S U M M I T A V E . TO MP 379 APPROX . 1 , 360' PROP. TRACK #6 PROP. TRACK #7 (BY OTHERS) FUTURE TRACK PLATFORM SERVICE PROP. 663' TO CONCORD (SEE SHTS U-1 THRU U-9) RELOC. SEWER LINE W I N O N A S T R E E T 5 0' P U B L I C R / W GRAHAM STREET 50' PUBLIC R/W PAD (26'-9"X10') PROP. CONCRETE TES TES GUARDRAIL MARKERS WITH INSTALL END OF ROAD 1 6 . 5 ' 2 3 ' 8 5 ' 1 1 5 ' PROP. BUMPING POST 123.60+03.66 287.66 +00.58 201.16 +30.07 263.08 +10.77 347.46 +82.09 415.96 +11.04403.40 +13.24 500.61 +48.91 313.76 +80.61 326.62 +55.21 376.36 +89.96 424.09 +89.33 65.48 +72.48 59.94 +53.73 48.31 +56.70 32.35 +22.60 162.05 +72.48 10.73 +28.15 9.46 +72.48 S T A . 1 3 5 + 7 3 . 5 8 S T A . 1 3 4 + 4 8 . 6 4 S T A . 1 2 9 + 1 0 . 2 0 PROP. BUMPING POST S T A . 1 3 9 + 6 0 . 4 8 PROP. FENCE (TYP.) 24' CROSSING BUILDING PROP. COMPRESSOR 18.50 +45.20 32.00 +45.20 18.50 +96.20 32.00 +96.20 DRIP PANS (TYP.) PROP. 85' 24' CROSSING SHED STORAGE PROP. S T A . 1 2 7 + 2 1 .4 0 T R A C K 7 W I T H L I G H T B L U E F L AG D E R A I L S T A . 12 7 + 9 7 .3 1 T R A C K 6 W I T H L I GH T B L U E F L AG D E R A I L T R A C K 5 S T A . 12 8 + 10 .2 0 W I T H L I G H T B L U E F L A G D E R A I L T R A C K 5 S T A . 1 3 5 + 9 8 . 5 8 W I T H L I G H T B L U E F L A G D E R A I L T R A C K 6 S T A . 1 3 6 + 6 9 . 7 7 W I T H L I G H T B L U E F L A G D E R A I L TRACK #5 PROP. & GUTTER 10' DEPRESSED CURB M A T C H L I N E P R O P . T R A C K # 5 S T A . 1 2 8 + 0 0 S E E S H E E T 4 5 RESPECTIVELY 5, 6, &7 PROFILES, FOR PROP. TRACKS SEE SHEETS 7 THRU 9 BE ACQUIRED BY NCDOT PARCELS 31 & 32 (CP&F) WILL STA. 128+00.00 TO STA. 140+72.48 PLAN -TRK5 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3/4/2016 blindje I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CK_Track_Rail\Plot Sheets\4015156_SHT_6.dgn RAIL DESIGN ENGINEER R/W SHEET NO. PROJECT REFERENCE NO.SHEET NO. HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ONA L E NGINEERMORI A H B. ELLINGTON 031992 SEAL 6P-2918F -AR1- PROP. ACCESS ROAD 710 720 710 700 690 730 740 680 670 660 650 740 730 720 700 690 680 670 660 650 DETAIL AUTOTURN 15SY PROP. SIDEWALK, 13SY PROP. SIDEWALK, STANDARDS) 2'6" WIDE (USE NCDOT CURB AND GUTTER, PROP. DEPRESSED AND GUTTER PROP. CURB PROP. INLET (TYP.) 684.81 684.81 FACILITY) WITH WB-50 (RH TURN INTO PROP. AUTOTURN SIMULATION FACILITY) (LH TURN INTO WITH WB-50 SIMULATION PROP. AUTOTURN 1 3 5 GAS LINE LOCATION PER FIELD MARKINGS OUTSIDE R/W BRUSH BRUSH BRUSH BRUSH BRUSH BRUSH S-M HARDWOODS BRUSH BRUSH BRUSH BRUSH HARDWOODS GV W MW M W M P O T St a. 1 3 4 + 0 0 . 0 0 P C St a. 1 3 9 + 5 8 . 3 4 1 4 0 P T Sta. 14 0 +5 3.0 3 POT Sta. 16+11.02 1 1 +0 0 1 2 +0 0 1 3 +0 0 1 4 +0 0 1 5 +00 1 6 +00 0.00' +69.62 7.39' +79.95 38.04' +69.90 PROP. TRACK #6 ROAD ACCESS PROP. W. S U M MIT A V E N U E ROAD PROP. ACCESS PROP. TRACK #5 R 1 1 0 0' 10.00' +00.64 12.58' +91.30 14.94' +35.73 R 2 0 0' 24.27' +72.75 R106' R 4 0' 43.86' +92.71 R 3 0 ' 0.00' +07.52 R 4 0 0 ' E:1443799.6543 N:540733.5036 (SUMMIT AVE) POT Sta. 13+20.06 (ACCESS RD) POT Sta. 141+16.07= EQUALITY: 90°16'15.7" C-ROAD-1 CURVE DATA RADIUS = 404.0' LENGTH = 94.45' TANGENT = 47.56' C-ROAD-1 684.00 684.81 684.81 57.6-FT 6x6 RCBC 57.6-FT 6x6 RCBC 685.04 685.04 684.35 684.00 684.00 33.1-FT 18" RCP 683.54 60.5-FT 36" RCP 694.26 695.26 695.26 694.63 695.34 691.50 693.15 683.00 682. 20 682.77682.77 691.64 691.64 691.15 1 4 0 1 1 +0 0 1 2 +0 0 1 3 +0 0 1 4 +0 0 1 5 +00 ROAD ACCESS PROP. W. S U M MIT A V E N U E ROAD PROP. ACCESS PROP. TRACK #5 WB-50 INDOT 201 3 (US) (c) 2014 Transoft Solutions, Inc. All rights reserved. WB-50 INDOT 2013 (US) (c) 2014 Transoft Solutions, Inc. All rights reserved. W B-50 IND OT 2013 (US) (c) 2014 Transoft Solutions, Inc. All rights reserved. WB-50 INDOT 2013 (US) (c) 2014 Transoft Solutions, Inc. All rights reserved. 128129130131132133134135136137138139140141 6 9 8 .3 9 6 9 8 .1 1 6 9 7 .9 8 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .9 7 6 9 7 .0 5 PI = 140+37.17 EL = 697.97' VC=60 PROP. ACCESS RD. EXIST. GROUND ALONG PROP. ACCESS RD PROP. GRADE TRACK #5 T/RAIL PROP. DETAIL FOR DESIGN PAST THIS POINT PLANTING STRIP (2'-6" CURB AND GUTTER) DROP CURB TYPE ii DRIVEWAY WITH SEE CITY OF CHARLOTTE COMMERCIAL E L E V = 6 9 4 .8 5 ' P R O P O S E D G R AD E S T A . 14 0 + 8 6 .4 2 P R O P . A C C E S S R D . E N D C O N S T R U C T I ON (-)6.0002%(-)0.0000% 7 0 2 . 0 6 7 0 5 .2 3 7 0 4 . 7 0 7 0 4 . 1 9 7 0 3 .6 7 7 0 3 . 1 6 7 0 2 .6 3 7 0 1 .4 3 7 0 0 . 7 6 7 0 0 . 1 0 6 9 9 .3 5 6 9 8 . 7 0 6 9 7 .9 7 6 9 7 . 2 6 6 9 6 . 5 6 6 9 5 . 8 9 6 9 5 .2 1 6 9 4 . 5 4 6 9 3 .8 5 6 9 3 .1 7 6 9 2 . 5 0 6 9 1 . 8 2 6 9 1 . 2 0 6 9 0 .6 3 6 9 0 .0 8 6 8 9 . 5 2 6 8 9 .0 3 6 9 8 . 9 0 6 9 8 . 6 3 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 EXIST. GROUND ELEV. PROP. TOP OF RAIL ELEV. PROP. TOP OF PAVEMENT ELEV. FLOW INE ELEV. PROP. CURB 0.25% CURB 0.25% CURB 0.25% CURB 0.25% CURB 0.25% CURB 0.25% CURB 0.25% CURB 0.25% CURB 0.25% CURB 0.25% CURB SLOPE ROADWAY MATCHES CURB SLOPE R I M E L E V = 6 9 8 .15 P R O P . I N LE T R I M E L E V = 6 9 7 .7 2 P R O P . I N LE T R I M E L E V = 6 9 7 .7 2 P R O P . I N LE T R I M E L E V = 6 9 7 .7 2 P R O P . I N LE T R I M E L E V = 6 9 7 .7 2 P R O P . I N LE T R I M E L E V = 6 9 7 .7 2 P R O P . I N LE T SECTIONS FOR DETAILS. TO STA. 140+07.00. SEE CROSS GEOMETRY FROM STA. 122+00.00 FOLLOWS TOP OR RAIL PROFILE ROADWAY VERTICAL GEOMERTY S-M HARDWOODS 1 4 0 1 3 5 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 blindje3/4/2016 I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CK_Track_Rail\Plot Sheets\4015156_SHT_7.dgn ENGINEER RAIL DESIGN PROJECT REFERENCE NO.SHEET NO. HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ONA L E NGINEERMORI A H B. ELLINGTON 031992 SEAL 740 730 720 710 700 690 680 670 720 710 700 690 730 740 680 670 660 660 740 730 720 710 700 690 680 670 660 720 710 700 690 730 680 670 660 750 7 127128 124125126 122123 121 P-2918F 120 117118119 115116 114 141 138139140 136137 135 134 131132133 129130 128 PLAN VIEW 4 FOR SEE SHEET PLAN VIEW 4A FOR SEE SHEET N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL 650650 PROFILE MAIN TRACK 5 PROPOSED (+) 0.4000% INV. OUT = 699.79' INV. IN = 701.38' PROP. 18" RCP STA. 125+07 +/- STAGE 1 E L E V = 6 9 9 .7 6 - T R K 5 - L T S T A 12 5 + 0 0 8 .0 ' B A S E D I T C H S P E C L A T E L E V = 6 9 9 .5 8 - T R K 5 - R T S T A 12 4 + 5 0 2 .0 ' B A S E D I T C H S P E C L A T E L E V = 7 0 4 .14 - T R K 5 - R T S T A 12 1 + 0 0 2 .0 ' B A S E D I T C H S P E C L A T E L E V = 7 0 2 .5 0 - T R K 5 - L T S T A 12 0 + 5 0 2 .0 ' B A S E D I T C H S P E C L A T DRAINAGE AREA DESIGN FREQUENCY DESIGN DISCHARGE DESIGN HW ELEVATION 100 YEAR DISCHARGE OVERTOPPING ELEVATION PIPE HYDRAULIC DATA AC YRS CFS CFS FT FT = 702.61 = 702.30 = 5.50 DOUBLE 18' RCP -TRK5- Sta. 123+71 LT. = 100 = 17.2 = 20.03 (-) 0.4000% E L E V = 7 0 3 .3 0 S T A 11 8 + 5 0 - T R K 5 - L T 2 .0 ' B A S E D I T C H B E G S P E C L A T E L E V = 7 0 3 .4 8 - T R K 5 - LT S T A 1 2 2 + 0 0 2 .0 ' B A S E D I T C H B E G S P E C L A T E L E V = 7 0 2 .7 0 - T R K 5 - L T S T A 1 2 1 + 0 0 2 .0 ' B A S E D I T C H E N D S P E C L A T (-) 1.77% (-) 0.59%(-) 1.03% (-) 0.36% E L E V = 7 0 4 .5 S T A 12 0 + 0 0 - T R K 5 - R T 2 .0 ' B A S E D I T C H B E G S P E C L A T E L E V = 7 0 0 .3 3 - T R K 5 - LT S T A 12 4 + 0 3 .3 0 8 .0 ' B A S E D I T C H S P E C L A T E N D 2 - 1 8 " C U L V E R T (-) 1.13% (-) 0.67% E L E V = 7 0 0 .6 0 - T R K 5 - LT S T A 12 3 + 6 2 .8 0 8 .0 ' B A S E D I T C H B E G S P E C L A T 2 .0 ' B A S E D I T C H E ND S P E C L A T B E G 2 - 1 8 " C U L V E R T STAGE 1 ELEV. = UNKNOWN EXIST. BOTTOM OF GIRDER EXIST. I-277 BRIDGE ELEV. = 731.75 +/- EXIST. BOTTOM OF GIRDER EXIST. W. CARSON BLVD. BRIDGE TOP OF RAIL EXIST. MAIN TRACK E L E V = 7 0 7 .9 4 ' P R O P . T / R A I L V P C S T A . 11 6 + 5 0 .0 0 P R O P . T R A C K #5 B E G I N C ON S T R U C T I ON B E G I N P R O J E C T B L VD . OV E R P A S S E X I S T . C A R S ON S T A . 12 1 + 3 5 .4 2 MAIN TRACK T/RAIL EXIST.PROP. TRACK #5 EXIST. GROUND ALONG SIDING TRACK T/RAIL EXIST. ELEV. = 694.34 WATER LINE 54"-DIA. PCCP STA. 122+11 +/- S T A . 12 5 + 2 1 .3 4 (T O B E R E M OV E D ) C / L P A L M E R S T R E E T r = 0.5373 VC = 150' EL = 707.40' PI = 117+25.00 VC #1 r = 0.8879 VC = 150' EL = 707.70' PI = 120+75.00 VC #2 r = 0.6240 VC = 200' EL = 698.52' PI = 128+10.20 VC #3 E L E V . = 7 0 7 .6 3 ' P R O P . T / R A I L V P C S T A . 12 0 + 0 0 .0 0 E L E V . = 7 0 7 .4 6 ' P R O P . T / R A I L V P T S T A . 11 8 + 0 0 .0 0 E L E V . = 7 0 6 .7 6 ' P R O P . T / R A I L V P T S T A . 12 1 + 5 0 .0 0 E L E V . = 6 9 9 .7 7 ' P R O P . T / R A I L V P C S T A . 12 7 + 10 .2 0 TOP OF RAIL EXIST. SIDING TRACK (STAGE 1) TRACK #5 T/RAIL PROP. E L E V . = 7 0 6 .2 6 ' P R O P . T / R A I L S T A . 12 1 + 8 9 .9 5 B E G I N P R O P . T R A C K 6 N o . 10 R B M L H T O P S P R O P . E L E V . = 7 0 4 .8 7 ' P R O P . T / R A I L S T A . 12 3 + 0 0 .9 5 N o . 10 R B M R H T O LL T P R O P . CONST. LIMITS END PROP. NSR CONST. LIMITS BEGIN PROP. NCDOT + 13 .3 9 (-)0.7222%(+)0.0838% (-)1.2480% V E R T . C LE A R . 2 3 ' - 10 1 / 2 " M I N . T O P O F R A I L ) (E X I S T . M A I N T R A C K 7 0 8 . 9 4 7 0 8 . 4 7 7 0 8 .3 8 7 0 8 . 1 9 7 0 7 . 9 9 7 0 7 . 7 6 7 0 7 . 4 4 7 0 7 .0 5 7 0 6 . 6 6 7 0 6 . 2 4 7 0 5 .7 5 7 0 5 .2 3 7 0 7 . 8 7 7 0 7 .0 5 7 0 7 . 4 4 7 0 7 . 1 6 7 0 7 . 0 2 7 0 7 .0 8 7 0 7 .1 1 7 0 7 .1 8 7 0 7 .4 1 7 0 8 . 6 9 7 0 7 .7 8 7 0 8 .0 1 -- - 7 0 7 .9 4 7 0 7 .6 5 7 0 7 .4 9 7 0 7 .4 6 7 0 7 . 5 1 7 0 7 .5 5 7 0 7 .5 9 7 0 7 .6 3 7 0 7 .5 6 7 0 7 .2 7 7 0 6 .7 6 7 0 6 .1 4 7 0 5 . 5 1 7 0 4 .8 9 7 0 4 .2 6 7 0 3 .6 4 7 0 3 .0 2 7 0 2 .3 9 7 0 1 .7 7 7 0 1 .1 4 7 0 0 .5 2 6 9 9 .9 0 6 9 9 .3 2 6 9 8 .9 0 T O P O F R A I L ) (E X I S T . M A I N T R A C K T O P O F R A I L ) (P R O P . T R A C K # 5 T O P O F R A I L ) (E X I S T . M A I N T R A C K T O P O F R A I L ) (P R O P . T R A C K # 5 T O P O F R A I L ) (E X I S T . S I D I N G T R A C K E L E V = 6 8 7 .7 2 - T R K 5 - R T S T A 13 6 + 2 5 4 .0 ' B A S E D I T C H B E G S P E C L A T E L E V = 6 9 1 .4 6 - T R K 5 - LT S T A 13 3 + 5 0 S W A T T E N U A T O R B E G I N 2 5 .0 ' 8 .0 ' B A S E D I T C H E ND S P E C L A T E L E V = 6 9 5 .6 5 - T R K 5 - LT S T A 12 9 + 0 0 8 .0 ' B A S E D I T C H S P E C L A T DRAINAGE AREA DESIGN FREQUENCY DESIGN DISCHARGE DESIGN HW ELEVATION 100 YEAR DISCHARGE OVERTOPPING ELEVATION PIPE HYDRAULIC DATA AC YRS CFS CFS FT FT = 697.83 = 697.05 = 0.90 18' RCP -TRK5- Sta. 129+00 TO 136+00 RT = 100 = 3.6 = 6.46 (+) 19.25 4 8 % DRAINAGE AREA DESIGN FREQUENCY DESIGN DISCHARGE DESIGN HW ELEVATION 100 YEAR DISCHARGE OVERTOPPING ELEVATION PIPE HYDRAULIC DATA AC YRS CFS CFS FT FT = 695.85 = 691.05 DOUBLE 6X6 RCBC -TRK5- Sta. 140+18 = 100 = 80.60 = 484.0 = 986.71 E L E V = 6 8 8 .9 0 - T R K 5 - LT S T A 13 6 + 2 5 2 5 .0 ' B A S E D I T C H E ND S P E C L A T INV. OUT = 685.54' INV. IN = 685.80' PROP. 36" RCP STA. 139+62 +/- INV. OUT = 684.81' INV. IN = 685.04' 2@6' X 6' RCBC Sta. 140+18 +/- INV. OUT = 686.46' INV. IN = 688.43' PROP. 36" RCP STA. 136+70 +/- E L E V = 6 9 5 .5 3 T R K 5 - L T S T A 1 4 0 + 7 2 .4 8 A T T E N U A T O R S T O R M W A T E R E ND 2 5 .0 ' (-) 1.03% (-) 1.03%(-) 0.93% (-) 0.93% (-) 0.67% (+) 0.21%(-) 0.21% (-) 10.16% E L E V = 6 9 6 .5 8 - T R K 5 - R T S T A 12 9 + 0 0 V D I T C H B E G S P E C L A T 2 .0 ' B A S E D I T C H E N D S P E C L A T B E G 18 " C U L V E R T E L E V = 6 8 8 .9 0 S T A 13 6 + 0 0 - T R K 5 - L T S W A T T E N U A T O R B E G 2 5 .0 ' E L E V = 6 8 8 .0 0 S T A 13 8 + 0 0 - T R K 5 - R T B E G D E T E N T I ON P ON D 2 .0 ' B A S E D I T C H E ND S P E C L A T E L E V = 6 9 1 .3 9 S T A 13 6 + 0 0 - T R K 5 - R T 2 .0 ' B A S E D I T C H B E G S P E C L A T V D I T C H E ND S P E C L A T E N D 18 " C U L V E R T(-) 1.12% ELEV=682.24 STA 141+08.88 -TRK5- RT 4.0' BASE DITCH END SPEC LAT MAIN TRACK T/RAIL EXIST. S T A . 12 9 + 3 1 .2 1 (T O B E R E M OV E D ) C / L P E N M A N S T R E E T S T A . 12 9 + 2 5 .0 0 R OA D CR O S S I N G C / L P R O P . A CC E S S r = 0.6240 VC = 200' EL = 698.52' PI = 128+10.20 VC #3 E L E V . = 6 9 8 .5 2 ' P R O P . T / R A I L V P T S T A . 12 9 + 10 .2 0 PROP. TRACK #5 EXIST. GROUND ALONG (STAGE 1) TRACK #5 T/RAIL PROP. E L E V . = 6 9 8 .5 2 ' P R O P . T / R A I L S T A . 13 8 + 7 2 .4 8 E ND P R O P . T R A C K 6 P S P R O P . N o . 10 L H T O E L E V . = 6 9 8 .5 2 ' P R O P . T / R A I L S T A . 13 7 + 6 1 .4 8 LL T P R O P . N o . 10 R H T O MAIN TRACK T/RAIL EXIST. E L E V = 6 9 8 .5 2 ' P R O P . T / R A I L S T A . 14 0 + 7 2 .4 8 P R O P . T R A C K # 5 E N D C O N S T R U C T I O N E ND P R O J E C T (STAGE 2) TRACK #5 T/RAIL PROP. (STAGE 2) PROP. TRACK #5 EXIST. GROUND ALONG PROPOSED 613' SERVICE PLATFORM STAGE 2 STAGE 1 + 0 0 .0 0 (+)0.0000%(+)0.0000% T O P O F R A I L ) ( E X I S T . M A I N T R A C K T O P O F R A I L ) (E X I S T . M A I N T R A C K 7 0 2 . 0 6 7 0 4 . 7 0 7 0 4 . 1 9 7 0 3 .6 7 7 0 3 . 1 6 7 0 2 .6 3 7 0 1 .4 3 7 0 0 . 7 6 7 0 0 . 1 0 6 9 9 .3 5 6 9 8 . 7 0 6 9 7 .9 7 6 9 7 . 2 6 6 9 6 . 5 6 6 9 5 . 8 9 6 9 5 .2 1 6 9 4 . 5 4 6 9 3 .8 5 6 9 3 .1 7 6 9 2 . 5 0 6 9 1 . 8 2 6 9 1 . 2 0 6 9 0 .6 3 6 9 0 .0 8 6 8 9 . 5 2 6 8 9 .0 3 -- - 6 9 8 .9 0 6 9 8 .6 3 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 T O P O F R A I L ) (P R O P . T R A C K # 5 T O P O F R A I L ) ( E X I S T . M A I N T R A C K T O P O F R A I L ) (P R O P . T R A C K # 5 T O P O F R A I L ) (E X I S T . M A I N T R A C K DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 blindje3/4/2016 I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CK_Track_Rail\Plot Sheets\4015156_SHT_8.dgn ENGINEER RAIL DESIGN PROJECT REFERENCE NO.SHEET NO. HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ONA L E NGINEERMORI A H B. ELLINGTON 031992 SEAL 740 730 720 710 700 690 680 670 650 138 134 135136137 720 710 700 690 650 730 740 680 670 660 660 740 730 720 710 700 690 680 670 660 720 710 700 690 730 680 670 660 133 750 8 PLAN VIEW 4 & 5 FOR SEE SHEETS 127128129130131132 124125126 122123 121 P-2918F 134139 PLAN VIEW 4, 5 & 5A FOR SEE SHEETS PROFILE MAIN TRACK 6 PROPOSED E L E V . = 6 9 8 .5 2 ' P R O P . T / R A I L S T A . 13 7 + 4 9 .2 2 LL T P R O P . N o . 10 R H T O PROP. TRACK #6 EXIST. GROUND ALONG T/RAIL EXIST. MAIN TRACK E L E V . = 6 9 8 .5 2 ' P R O P . T / R A I L S T A . 13 8 + 6 0 .6 2 P R O P . T R A C K 6 E N D C ON S T R U C T I ON P S P R O P . N o . 10 L H T O STAGE 1STAGE 2 + 8 7 .0 9 PLATFORM PROPOSED 613' SERVICE TRACK #6 T/RAIL PROP. (+)0.0000% ( P R O P . T R A C K # 5 T O P O F R A I L ) (P R O P . T R A C K # 6 T O P O F R A I L ) ( P R O P . T R A C K # 5 T O P O F R A I L ) (P R O P . T R A C K # 6 T O P O F R A I L ) PROP. TRACK #6 EXIST. GROUND ALONG MAIN TRACK T/RAIL EXIST. T/RAIL PROP. TRACK #6 r = 0.6240 VC = 200' EL = 698.52' PI = 128+10.18 VC #1 S T A . 12 5 + 14 .2 0 (T O B E R E M OV E D ) C / L P A L M E R S T R E E T S T A . 12 9 + 2 6 .8 1 R OA D CR O S S I N G C / L P R O P . A C C E S S S T A . 12 9 + 2 2 .6 8 (T O B E R E M OV E D ) C / L P E N M AN S T R E E T E L E V . = 6 9 9 .7 7 ' P R O P . T / R A I L V P C S T A . 12 7 + 10 .18 E L E V . = 6 9 8 .5 2 ' P R O P . T / R A I L V P T S T A . 12 9 + 10 .18 E L E V . = 7 0 6 .2 6 ' P R O P . T / R A I L S T A . 12 1 + 8 9 .9 5 P R O P . T R A C K 6 B E G I N C ON S T R U C T I ON N o . 10 R B M R H T O P S P R O P . E L E V . = 7 0 4 .8 7 ' P R O P . T / R A I L S T A . 12 3 + 0 1 .3 5 N o . 10 R B M R H T O LL T P R O P . E L E V . = 7 0 4 .5 6 ' P R O P . T / R A I L S T A . 12 3 + 2 6 .3 5 N o . 10 R B M R H T O P S P R O P . E L E V . = 7 0 3 .17 ' P R O P . T / R A I L S T A . 12 4 + 3 7 .3 5 N o . 10 R B M R H T O LL T P R O P . [(+)0.0000%] (+)0.0000% PROPOSED 613' SERVICE PLATFORM (-)1.2480% (P R O P . T R A C K # 5 T O P O F R A I L ) ( P R O P . T R A C K # 6 T O P O F R A I L ) (P R O P . T R A C K # 5 T O P O F R A I L ) ( P R O P . T R A C K # 6 T O P O F R A I L ) 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 STAGE 1STAGE 2 6 8 9 .5 2 -- - ( P R O P . T R A C K # 5 T O P O F R A I L ) (P R O P . T R A C K # 6 T O P O F R A I L ) ( P R O P . T R A C K # 5 T O P O F R A I L ) (P R O P . T R A C K # 6 T O P O F R A I L ) S T A . 12 5 + 14 .2 0 (T O B E R E M OV E D ) C / L P A L M E R S T R E E T 7 0 6 .1 4 7 0 5 . 5 1 7 0 4 .8 9 7 0 4 .2 6 7 0 3 .6 4 7 0 3 .0 2 7 0 2 .3 9 7 0 1 .7 7 7 0 1 .1 4 7 0 0 .5 2 6 9 9 .9 0 6 9 9 .3 2 6 9 8 .9 0 6 9 8 .6 3 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 7 0 4 . 2 7 6 9 8 . 5 2 7 0 6 . 1 4 7 0 5 .5 1 7 0 4 . 8 9 7 0 3 .6 5 7 0 3 . 0 2 7 0 2 . 3 6 7 0 1 .7 1 7 0 1 .0 5 7 0 0 . 3 9 6 9 9 . 7 4 6 9 9 . 2 0 6 9 8 . 8 2 6 9 8 . 5 9 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 ( P R O P . T R A C K # 5 T O P O F R A I L ) (P R O P . T R A C K # 6 T O P O F R A I L ) ( P R O P . T R A C K # 5 T O P O F R A I L ) (P R O P . T R A C K # 6 T O P O F R A I L ) DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 blindje3/4/2016 I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CK_Track_Rail\Plot Sheets\4015156_SHT_9.dgn ENGINEER RAIL DESIGN PROJECT REFERENCE NO.SHEET NO. HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ONA L E NGINEERMORI A H B. ELLINGTON 031992 SEAL 740 730 720 710 700 690 680 670 660 720 710 700 690 730 680 670 660 750 9 PLAN VIEW 4 & 5 FOR SEE SHEETS 127128129130 124125126 123 P-2918F LEFT BLANK INTENTIONALLY THIS SPACE PROFILE MAIN TRACK 7 PROPOSED PROP. TRACK #7 EXIST. GROUND ALONG T/RAIL PROP. TRACK #6 T/RAIL PROP. TRACK #7 E L E V = 6 9 8 .5 2 ' P R O P . T / R A I L S T A . 13 0 + 0 0 .0 0 P R O P . T R A C K # 7 E N D C ON S T R U C T I ON S T A . 12 5 + 12 .9 0 (T O B E R E M O V E D ) C / L P A L M E R S T R E E T T/RAIL EXIST. MAIN TRACK r = 0.6240 VC = 200' EL = 698.52' PI = 128+10.18 VC #1 E L E V . = 6 9 9 .7 7 ' P R O P . T / R A I L V P C S T A . 12 7 + 10 .18 E L E V . = 6 9 8 .5 2 ' P R O P . T / R A I L V P T S T A . 12 9 + 10 .18 E L E V . = 7 0 4 .5 6 ' P R O P . T / R A I L S T A . 12 3 + 2 6 .3 5 P R O P . T R A C K #7 B E G I N C ON S T R U C T I ON N o . 10 R B M R H T O P S P R O P . E L E V . = 7 0 3 .17 ' P R O P . T / R A I L S T A . 12 4 + 3 7 .7 5 N o . 10 R B M R H T O LL T P R O P . (-)1.2480% (+)0.0000% ( P R O P . T R A C K # 6 T O P O F R A I L ) ( P R O P . T R A C K # 6 T O P O F R A I L ) 7 0 1 .7 5 6 9 9 .2 5 7 0 4 .2 6 7 0 3 .6 4 7 0 3 .0 2 7 0 2 .3 9 7 0 1 .1 0 7 0 0 .4 5 6 9 9 . 8 1 6 9 8 .8 5 6 9 8 . 6 1 7 0 4 .2 6 7 0 3 .6 4 7 0 3 .0 2 7 0 2 .3 9 7 0 1 .7 7 7 0 1 .1 4 7 0 0 .5 2 6 9 9 .9 0 6 9 9 .3 2 6 9 8 .9 0 6 9 8 .6 3 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 119+00 7 0 7 . 9 4 7 0 7 . 6 5 7 0 7 . 4 9 7 0 7 . 4 6 7 0 7 . 5 1 7 0 7 . 5 5 ( P R O P . T R A C K # 6 T O P O F R A I L ) (P R O P . T R A C K # 7 T O P O F R A I L ) ( P R O P . T R A C K # 6 T O P O F R A I L ) (P R O P . T R A C K # 7 T O P O F R A I L ) DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 140+00 135+00 130+00 125+00 120+00 115+00 (UNDERGRADE BRIDGE) W MOREHEAD ST BRIDGE) (OVERHEAD BLVD CARSON BRIDGE) (OVERHEAD FREEWAY JOHN BELK I-277 AVE W SUMMIT PENMAN ST PALMER ST 140+00 135+00 130+00 125+00 120+00 115+00 (UNDERGRADE BRIDGE) W MOREHEAD ST BRIDGE) (OVERHEAD BLVD CARSON BRIDGE) (OVERHEAD FREEWAY JOHN BELK I-277 AVE W SUMMIT PENMAN ST PALMER ST 13PENMAN ST PALMER ST 3 55 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 1 1 . d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL EXISTING CONDITIONS: MAINTENANCE FACILITY PROPOSED LOCOMOTIVE AND RAIL CAR P-2918F CONSTRUCTION PHASING TO MP 378 TO CONCORD TO MP 379 TO GASTONIA EXISTING (BEING REMOVED) EXISTING TRACK TURNOUT LEGEND UNDERGRADE) OR (OVERHEAD BRIDGE PROPOSEDITEM DESCRIPTION GRADE CROSSING SIGNALS MAST RAILROAD FROM STA. 129+60.20 TO STA. 135+73.58, AND CRASHWALL INSTALLATION STAGE 1, PHASE 1: RAILROAD ROADBED GRADING, DRAINAGE, PLATFORM CONSTRUCTION 11 5. CONSTRUCT CRASHWALLS AT CARSON BLVD OVERHEAD BRIDGE AND AT 1-277 OVERHEAD BRIDGE. UPON THE COMPLETION OF THE RELOCATION OF THE EXISTING 54" WATERLINE. 4. CONSTRUCT PROPOSED RAILROAD ROADBED FROM -TRK5- STA. 119+40.00 TO STA. 123+00.95 THE PROPOSED SERVICE PLATFORM AND CONCRETE PADS FOR THE PROPOSED SHEDS. 3. CONSTRUCT PROPOSED RAILROAD ROADBED FROM -TRK5- STA. 123+00.95 TO STA. 136+00.00, INCLUDING 2. CONTRACTOR TO INSTALL EROSION CONTROL MEASURES. 1. CONTRACTOR TO CLOSE PENMAN AND PALMER STREETS TO THRU TRAFFIC. CONSTRUCTION PHASING DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 140+00 135+00 130+00 125+00 120+00 115+00 (UNDERGRADE BRIDGE) W MOREHEAD ST BRIDGE) (OVERHEAD BLVD CARSON BRIDGE) (OVERHEAD FREEWAY JOHN BELK I-277 AVE W SUMMIT 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 1 2 .d g n b l i n d j e PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ON A L E NGINEERMORI A H B. ELLINGTON 031992 SEAL 3 3 140+00 135+00 130+00 125+00 120+00 115+00 (UNDERGRADE BRIDGE) W MOREHEAD ST BRIDGE) (OVERHEAD BLVD CARSON BRIDGE) (OVERHEAD FREEWAY JOHN BELK I-277 AVE W SUMMIT 2 MAINTENANCE FACILITY PROPOSED LOCOMOTIVE AND RAIL CAR P-2918F CONSTRUCTION PHASING TO MP 378 TO CONCORD TO MP 379 TO GASTONIA STAGE 1, PHASE 2: EXISTING (BEING REMOVED) EXISTING TRACK TURNOUT LEGEND UNDERGRADE) OR (OVERHEAD BRIDGE PROPOSEDITEM DESCRIPTION GRADE CROSSING SIGNALS MAST RAILROAD 12 2 2. CONSTRUCT PROPOSED RAILROAD ROADBED FROM -TRK5- STA. 136+00.00 TO STA. 140+72.48 ONCE THE PARCEL BECOMES AVAILABLE 1. CONTRACTOR TO INSTALL EROSION CONTROL MEASURES. CONSTRUCTION PHASING (CONT'D) STAGE 2, PHASE 1: 4. AT THE END OF THIS PHASE, MAINTENANCE OPERATIONS CAN OCCUR WITHIN THE YARD. 3. NS FORCES TO REMOVE THE EXISTING TURNOUT AND REMAINING SIDING TRACK TO STA. 116+50. AND FROM STA. 124+37.35 TO STA. 138+60.62, -TRK7- STA. 124+37.75 TO STA. 130+00.00, INCLUDING ALL PROP. No. 10 LH AND RH TURNOUTS. 2. CONSTRUCT PROPOSED TRACK FROM -TRK5- STA. 116+50 TO STA. 140+72.48, -TRK6- STA. 123+01.35 TO STA. 123+26.35 1. CONTRACTOR TO INSTALL EROSION CONTROL MEASURES. DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 FOOTINGS PROPOSED { EXISTING & A A 7'-8"9'-0"7'-8"9'-0"7'-8"9'-0"7'-8"9'-0" 3'-10Ž" 3 " 2 ' - 6 " 4'-7•"4'-7•" (TYP. LL)(TYP. LL) 4'-6" (TYP. RL) 4'-6" (TYP. RL) 17'-2"17'-2"17'-2"17'-2"16'-8"16'-8"16'-8"16'-8"{ EXISTING 3'-6" DIA. CONCRETE COLUMNS 9'-3"7'-11"9'-3"7'-11"9'-3"7'-11"9'-3"7'-11"9'-3" NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 DRAWN BY : CHECKED BY : DATE : DATE : Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. PLAN & ELEVATION P-2918F VMW PEK NOTES: 1" JT. EXP. (TYP.) STRUT CONCRETE EXISTING 3 ' - 3 " 4'-6"6'-6" 2'-6" STRUT CONCRETE EXISTING 118+95.67 -TRK5- 9'-0" SECTION A-A (FOR DOWEL DETAILS SEE SHEET S-2) LL = LEFT LANE RL = RIGHT LANE 1" EXP. JT. 4 ' - 6 " CRASHWALL BRIGES AT I-277 OVER NORFOLK SOUTHERN RAILROAD 2'-9" 2'-10•"MECKLENBURG S-1 10 SHEET 1 OF 3 1-16 1-16 1 3 ' - 6 " (L L ) 6 ' - 9 " (L L ) 6 ' - 9 " (L L ) 1 3 ' - 3 " ( R L ) 6 ' - 7 • " (R L ) 6 ' - 7 • " ( R L ) ELEVATION - LEFT LANE ELEVATION - RIGHT LANE PLAN - LEFT LANE PLAN - RIGHT LANE 13'-1Š" UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL FOOTING (TYP.) PROPOSED CONCRETE FOOTING (TYP.) EXISTING CONCRETE CRASHWALL CONCRETE PROPOSED FOOTING (TYP.) PROPOSED CONCRETE FOOTING (TYP.) EXISTING CONCRETE CONCRETE CRASHWALL PROPOSED FACE OF CONCRETE CRASHWALL PROPOSED BACK OF (TYP.) COLUMN CONCRETE 3'-6" DIA. EXISTING EL. 718.00 13'-6" FOOTING PROPOSED CONCRETE (TYP.) BENT CAP CONCRETE EXISTING BENT CAP CONCRETEEXISTING CONCRETE COLUMN 3'-6" DIA.EXISTING CRASHWALL PROPOSED CONCRETE REPAIR CONCRETE 1.0 SF. SIDE) (SPAN C REPAIR CONCRETE 1.0 SF. DETAIL SEE SHEET S-2 FOR COLUMN DOWEL DETAIL SEE SHEET S-2 FOR FOOTING DOWEL EL. 718.00 THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE FOR GROUT FOR STRUCTURED, SEE SPECIAL PROVISIONS. FOR FALSEWORK AND FORMWORK, SEE SPECIAL PROVISIONS. FOR SUBMITAL OF WORKING DRAWINGS, SEE SPECIAL PROVISIONS. BRIDGES. COMPLETE CONCRETE REPAIRS BEFORE CONSTRUCTING CRASH WALLS. SEE SHEET S-10 FOR DETAILS. BY THE ENGINEER. REPAIRS WILL ONLY BE PERFORMED ON THE EXISTING BENT 2 OF THE LEFT AND RIGHT PERFORM CONCRETE REPAIRS AND EPOXY RESIN INJECTION WHERE INDICATED ON THE PLANS AND AS DIRECTED TOP OF CRASHWALL SHALL BE A MINIMUM OF 10'-0" ABOVE ADJACENT TOP OF RAIL. THE PLANS AND THE ACTUAL CONDITIONS AT THE PROJECT SITE. ADDITIONAL COST INCURRED BASED ON DIFFERENCES BETWEEN THE EXISTING BRIDGE SUBSTRUCTURE SHOWN ON SHALL HAVE NO CLAIM WHATSOEVER AGAINST THE DEPARTMENT OF TRANSPORTATION FOR ANY DELAYS OR AVAILABLE. SINCE THIS INFORMATION IS SHOWN FOR THE CONVENIENCE OF THE CONTRACTOR, THE CONTRACTOR THE SUBSTRUCTURE OF THE EXISTING BRIDGE INDICATED ON THE PLANS IS FROM THE BEST INFORMATION 6. 5. 4. 3. 2. 1. E. L KELLY,JR. A PU19765 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 COLUMN DOWEL DETAIL FOOTING EXISTING CONCRETE NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET 2 OF 3 DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG 118+95.67 -TRK5- VMW PEK Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. 2 ' - 3 " 1 ' - 5 " E M B E D . VERTICAL DOWEL DETAIL CONCRETE TOP OF EXISTING 2'-3"1'-5" EMBED. CONCRETEFACE OF HORIZONTAL DOWEL DETAIL COLUMNCONCRETE EXISTING 3'-6" DIA. STRUT EXISTING CONCRETE 10 " 11 S P A . @ 1 ' - 0 " = 1 1 ' - 0 " 6"12 SPA. @ 1'-0" = 12'-0" FOOTING EXISTING CONCRETE EXISTING COLUMNS AND FOOTINGS) FOR EMBEDMENT LENGTHS INTO (SEE HORIZONTAL DOWEL DETAIL EXISTING COLUMNS AND FOOTINGS) FOR EMBEDMENT LENGTHS INTO (SEE HORIZONTAL DOWEL DETAIL FOOTING DOWEL DETAIL SECTION B-B CONSTRUCTION JOINT CONSTRUCTION JOINT FOOTING EXISTING CONCRETE 1'-0" (RL) 1'-1•" (LL) 1'-0" (RL) 1'-1•" (LL) B B FOOTING (TYP.) PROPOSED CONCRETE NOTES: 1'-7" EXISTING COLUMNS AND FOOTINGS) FOR EMBEDMENT LENGTHS INTO (SEE VERTICAL DOWEL DETAIL ADHESIVELY ANCHORED DOWEL ADHESIVELY ANCHORED DOWEL CRASHWALL DETAILS BRIDGES AT I-277 OVER NORFOLK SOUTHERN RAILROAD S-2 10 #6D1 (TYP.) (TYP.) #6D1 #6D1 (TYP.) 1-16 1-16 UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL 5 " (L L ) 3 " ( R L ) 3 " ( L L ) 4 " ( R L ) #6D1 #6D1 10"10" 3 SPA.1'-2"|1'-2"| @ 1'-0" LL = LEFT LANE RL = RIGHT LANE 6 " 7 " 6. 5. 4. 3. 2. 1. THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE PROPOSED DOWELS IS PREFERED. PROPOSED LOCATION. MOVING DOWEL IN LINE WITH OTHER PROPOSED DOWELS, DOWELS MAY BE MOVED UP TO 3" FROM WHEN EXISTING REINFORCEMENT IS IN CONFLICT WITH DEPTH. ADVANCING PILOT HOLE IN ‚" INCREMENTS UP TO A 4" BEFORE CHECKING FOR REINFORCEMENT. CONTINUE ADVANCE PILOT HOLES NO MORE THAN ‚" AT A TIME PILOT HOLES TO CHECK FOR EXISTING REINFORCEMENT. WITH THE PROPOSED DOWELS. THE CONTRACTOR WILL DRILL WILL ENCOUNTER EXISTING REINFORCEMENT IN CONFLICT IT IS STILL HIGHLY PROBABLE THAT THE CONTRACTOR EXISTING REBAR IS LESS LIKELY TO BE PLACED. HOWEVER, ADHESIVELY ANCHORED DOWELS HAVE BEEN LOCATED WHERE SPECIAL PROVISIONS. ADHESIVELY ANCHORED ANCHOR BOLTS OR DOWELS, SEE PROVISIONS. NO FIELD TESTING IS REQUIRED. FOR THE MANUFACTURER'S RECOMMENDATIONS AND THE SPECIAL ADHESIVELY ANCHORED DOWELS SHALL BE INSTALLED PER STANDING WATER. BE APPLIED TO SURFACES THAT HAVE VISIBLE OR APPROXIMATELY 100 PSI. BONDING COMPOUND SHALL NOT BOTTOM DISCHARGE PRESSURE VESSEL OPERATING AT APPLIED AS A SPRAY APPLICATION BY USE OF A BINKS IS FURTHER RECOMMENDED THAT BONDING COMPOUND BE ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. IT PRODUCTS LIST. BONDING SYSTEM SHALL BE APPLIED IN BODING SYSTEM SHALL BE LISTED ON THE NCDOT APPROVED MATERIAL WITH AN EPOXY BONDING COMPOUND. EPOXY NEW CONCRETE SHALL BE BONDED TO CLEAN SOUND POTABLE WATER. WITH A DETERGENT AND THE SURFACE WASHED WITH CLEAN DUST. GREASE AND OIL SHALL BE SCRUBBED AND REMOVED AIR CLEANED WITH OIL FREE AIR TO REMOVE ALL LOOSE EXPOSED SURFACE SHALL BE WASHED WITH CLEAN WATER OR REMOVED AND THAT A CLEAN SOUND SURFACE REMAINS. THE FOREIGN MATERIAL AND LOOSE OR UNSOUND CONCRETE IS EITHER WATERBLASTING OR WIRE BRUSHED SO THAT ALL NEW CONCRETE WILL BE BONDED SHALL BE CLEANED BY THE SURFACE OF THE EXISTING MATERIAL TO WHICH THE GRADE 60 AND SHALL BE SPACED AS SHOWN ON THE PLANS. DOWELS SHALL BE MADE OF DEFORMED BARS, ASTM A615, SPECIFIED IN AREMA SPECIFICATIONS, CHAPTER 8, PART 14. SURFACE PREPARATION AND ANCHORAGE SHALL BE AS E. L KELLY,JR. A PU19765 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET 3 OF 3 DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG 118+95.67 -TRK5- VMW PEK Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. CRASHWALL DETAILS BRIDGES AT I-277 OVER NORFOLK SOUTHERN RAILROAD S-3 10 2" CL. (TYP.) #5V1 2 " C L . 3" (TYP.) 4 SPA. @ 6" CTS. 2'-6" 4-#5 "H" BARS #5S1 #5T1 #5L1 3" 28-#5 "T" BARS (14 EA. FACE) 3'-0" MIN. SPLICE #5H1 (2 BAR RUN) WITH 17'-2" COLUMNS SPA.) #5H3 (TYP. @ 2 " C L . (T Y P . ) 9'-3"|7'-11"9'-3"|3'-10Ž"9'-3"| #5U2 (TYP.) 9'-0"|7'-8"9'-0"| #5H2 #5H4 #5H2 3'-0" MIN. SPLICE #5H5 (2 BAR RUN) WITH 16'-8" COLUMNS SPA.) #5H6 (TYP. @ 9'-0"| #5H2 (FOOTING REINFORCING AND DOWEL BARS NOT SHOWN FOR CLARITY) 3 " 2" CL. (TYP.) 3 " C L . (T Y P . ) 3"3" 1'-0" 2 SPA. @ 1'-0" 3-#5V2 (TYP. @ COLUMNS) 4"4"13 SPA. @ 1'-0" 7-#5U2 (7 EA. FACE) & 14-#5V2 #5T2 FOOTING) (TYP. @ 7'-11" (8 EA. FACE) 16-#5T1 7'-11" 5" #5T3 (TYP.) #5L1 3"3" 1'-0" 2 SPA. @ 1'-0" 3-#5V2 (TYP. @ COLUMNS) 3"3"3"3" 8-#5V2 (4 EA. FACE) & 4-#5U2 4"4"7 SPA. @ 1'-0" FOOTING) (TYP. @ 7'-8" (7 EA. FACE) 16-#5T1 7'-8" #5T4 3" 3" CL. (TYP.) C C SECTION C-C (DOWEL BARS NOT SHOWN FOR CLARITY) FRONT FACE BACK FACE 2" CL. (TYP.) 7 SPA. @ 1'-0" M I N . S P L I C E 2 ' - 2 " 5•"5•" 7'-11" FOOTING) FACE) (TYP. @ 16-#5L1 (8 EA. 7 SPA. @ 11•" 7'-8" FOOTING) FACE) (TYP. @ 16-#5L1 (8 EA. 2" CL. (TYP.) 2" CL. (TYP.) (TYP.) EXIST. FOOTING (TYP.) EXIST. FOOTING 3 ' - 3 "| 3 " 3 SPA. @ 1'-0" MAX.3 SPA. @ 1'-0" MAX. 3 SPA. @ 1'-0" MAX. 13 SPA. @ 1'-0" MAX. 2" CL. (TYP.) 3 " C L . (T Y P . ) EXIST. STRUT EXIST. COLUMN (TYP.) EXIST. STRUT EXIST. COLUMN (TYP.) JT. 1" EXP. (DOWEL BARS NOT SHOWN FOR CLARITY) 2" CL. (TYP.) #5U2 (TYP.) 2 ' - 6 " ( T Y P . ) 2 " C L . PARTIAL ELEVATION - LEFT LANE PARTIAL ELEVATION - RIGHT LANE (FOOTING REINFORCING AND DOWEL BARS NOT SHOWN FOR CLARITY) (TYP.) FOOTING EXIST. (TYP.) FOOTING EXIST. (TYP.) COLUMN EXIST. (TYP.) COLUMN EXIST. 2 ' - 6 " 3 " C L . (T Y P . ) 3 ' - 3 "| 3 ' - 3 " 3 " ( T Y P . ) W I T H # 5 L 1 # 5 "V " B A R S 3 " C C EXIST. STRUT COLUMN EXIST. #5V2 13 - # 5 "H " B A R S 8-#5V2 (4 EA. FACE) & 4-#5U2 8-#5V2 (4 EA. FACE) & 4-#5U2 10 ' - 0 " M I N . (F I E L D V E R I F Y ) T O T O P O F R A I L REINFORCING SCHEDULE BAR NO.SIZE TYPE LENGTH WEIGHT BAR TYPE 6 ' - 2 " EXIST. STRUT EXIST. STRUT 1-16 1-16 #5V2 #5V2 2 " C L . (T Y P . ) 2 " C L . (T Y P . )(TYP.) #5L1 (TYP. @ 17'-2" COLUMNS SPA.) 14-#5S1 14-#5V2 (FRONT FACE), & 14-#5V1 (BACK FACE), (TYP. @ 16'-8" COLUMNS SPA.) 14-#5S1 14-#5V2 (FRONT FACE), & 14-#5V1 (BACK FACE), 2'-2"2'-2" 1 ' - 6 " 1 ' - 6 " UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL PLANS PRELIMINARY PARTIAL PLAN - LEFT LANE PARTIAL PLAN - RIGHT LANE 7 SPA. @ 1'-0"5•"5•" 3'-10Ž" 3 SPA. @ 1'-0" 8-#5T1 (4 EA. FACE) #5V2 3 4 - # 5 H 1 @ 1 ' - 0 " M A X . S P A . W I T H 3 ' - 0 " M I N . S P L I C E ( 2 B A R R U N F R O N T F A C E ) 1 2 S P A . @ 1 ' - 0 " 3 " 17 - # 5 H 4 @ 1 ' - 0 " M A X . S P A . 1 ' - 0 " M A X . S P A . 13 - # 5 H 3 @ 3 " 4•"6 SPA. @ 1'-0" 3 " 17 - # 5 H 2 @ 1 ' - 0 " M A X . S P A . 1 7 - # 5 U 2 16 S P A . @ 1 ' - 0 " M A X . 3 " 17 - # 5 H 2 @ 1 ' - 0 " M A X . S P A . 3 " 1 7 - # 5 H 2 @ 1 ' - 0 " M A X . S P A . #5V2 3 4 - # 5 H 5 @ 1 ' - 0 " M A X . S P A . W I T H 3 ' - 0 " M I N . S P L I C E ( 2 B A R R U N F R O N T F A C E ) 3 " 1 ' - 0 " M A X . S P A . 1 3 - # 5 H 6 @ 16 S P A . @ 1 ' - 0 " M A X . 1 7 - # 5 U 2 13 SPA. @ 1'-0" 13'-6" 3 4 - # 5 "H " B A R S @ 1 ' - 0 " M A X . S P A . ( 2 B A R R U N ) W I T H 3 ' - 0 " M I N . S P L I C E 81'-9Ž"75'-8" 5ƒ"5ƒ"6"@ 1'-0" 3 SPA. FACE) (4 EA. 8-#5L1 2'-0" THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE E. L KELLY,JR . APU19765 REINFORCING STEEL LBS. CU. YARDS 19,499 295.1 TOTAL REINFORCING STEEL = H1 #5 STR.42'-3"34 1,498 H2 #5 STR.2'-5"60 151 H3 #5 STR.13'-4"68 H4 #5 STR.6'-5"20 134 H5 #5 STR.39'-2"34 1,389 H6 #5 STR.68 12'-10" L1 #5136 1 8'-2" V1 #5 STR.1,43111212'-3" 19,499 LBS. V2 STR.3,082180#5 U2 #5 3 5'-2"28653 910 D1 STR.4,4178023'-8"#6 16'-5" 1 2 ALL BAR DIMENSIONS ARE OUT TO OUT 3 #5 STR.T1 13'-0"136 1,844 112 #5 STR.7'-6"T2 876 T3 #5 STR.3'-6"10228 T4 #5 STR.7'-3"847112 946 1,158 S1 #5112 2 3'-8"428 CLASS A CONCRETE BILL OF MATERIAL BENT 2 AT STA. 118+95.67 -TRK5- FOUNDATION EXCAVATION FOR LUMP SUM CF.0.8CONCRETE REPAIRS DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 8'-0"8'-0"15'-0"8'-0"8'-0" 4'-0"4'-0"4'-0"4'-0"4'-0"4'-0" (TYP.) COLUMNS CONCRETE { EXISTING FOOTING (TYP.) PROPOSED CONCRETE FOOTING (TYP.) EXISTING CONCRETE 5 ' - 0 " 5 ' - 0 " 1 0 ' - 0 " 4'-0"4'-0" FOOTINGS PROPOSED { EXISTING & PLAN COLUMN (TYP.) EXISTING CONCRETE CRASHWALL CONCRETE PROPOSED FOOTING (TYP.) EXISTING CONCRETE A A ELEVATION BENT 3 CRASHWALL NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET 1 OF 3 DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG 121+35.40 -TRK5- VMW PEK Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. EL. 717.82 2'-6‚" 2 ' - 0 " 2'-6" 2'-6" BENT CAP EXISTING CONCRETE COLUMN EXISTING CONCRETE STRUT EXISTING CONCRETE FOOTING PROPOSED CONCRETE 4" (BOT.) NOTES: 4'-0"4'-0" 10'-0" 11‡" (TOP) SECTION A-A CONCRETE CRASHWALL PROPOSED FACE OF CONCRETE CRASHWALL PROPOSED BACK OF PLAN & ELEVATION BRIDGE AT WEST CARSON BLD 15'-5"15'-5" BENT CAP EXISTING CONCRETE (FOR DOWEL DETAILS SEE SHEET S-5) FOOTING STRUT EXISTING CONCRETE S-4 OVER NORFOLK SOUTHERN RR 10 2 ' - 6 " 2 ' - 6 " 9 " 2'-3•" 5 ' - 7 ‚ " 9‚" 4'-11ƒ" CRASHWALL CONCRETE PROPOSED 1-16 1-16 SIDE) (SPAN D INJECTION RESIN EPOXY 1.5 LF. REPAIR (SPAN D SIDE) 0.5 SF. CONCRETE (SPAN D SIDE) RESIN INJECTION 2.7 LF. EPOXY (SPAN D SIDE) RESIN INJECTION 1.5 LF. EPOXY (COLUMN 3 ONLY) 1.0 SF. CONCRETE REPAIR UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL PLANS PRELIMINARY (TYP.) FOOTING STRUT EXISTING CONCRETE NOT SHOWN FOR CLARITY) (EXISTING CONCRETE COLUMN STRUT (LOOKING EAST) DETAIL SEE SHEET S-5 FOR COLUMN DOWEL DETAIL SEE SHEET S-5 FOR FOOTING DOWEL COLUMN STRUT (TYP.) EXISTING CONCRETE DETAIL SEE SHEET S-5 FOR FOOTING STRUT DOWEL 0.5 LF EPOXY RESIN INJECTION 2-1.0 SF. CONCRETE REPAIR &(COLUMN 3 ONLY) RESIN INJECTION 0.5 LF EPOXY (TYP.) EXISTING CONCRETE FOOTING STRUT PROPOSED CONCRETE FOOTING & TEMPORARY RAILROAD SHORING THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE FOR GROUT FOR STRUCTURED, SEE SPECIAL PROVISIONS. FOR FALSEWORK AND FORMWORK, SEE SPECIAL PROVISIONS. FOR SUBMITAL OF WORKING DRAWINGS, SEE SPECIAL PROVISIONS. FOR TEMPORARY RAILROAD SHORING, SEE SPECIAL PROVISIONS. 7 6. 5 4. 3. 2. 1. COMPLETE CONCRETE REPAIRS BEFORE CONSTRUCTING CRASH WALLS. SEE SHEET S-10 FOR DETAILS. DIRECTED BY THE ENGINEER. REPAIRS WILL ONLY BE PERFORMED ON THE EXISTING BENT 3 OF THE BRIDGE. PERFORM CONCRETE REPAIRS AND EPOXY RESIN INJECTION WHERE INDICATED ON THE PLANS AND AS TOP OF CRASHWALL SHALL BE A MINIMUM OF 10'-0" ABOVE ADJACENT TOP OF RAIL. SUBSTRUCTURE SHOWN ON THE PLANS AND THE ACTUAL CONDITIONS AT THE PROJECT SITE. DELAYS OR ADDITIONAL COST INCURRED BASED ON DIFFERENCES BETWEEN THE EXISTING BRIDGE CONTRACTOR SHALL HAVE NO CLAIM WHATSOEVER AGAINST THE DEPARTMENT OF TRANSPORTATION FOR ANY AVAILABLE. SINCE THIS INFORMATION IS SHOWN FOR THE CONVENIENCE OF THE CONTRACTOR, THE THE SUBSTRUCTURE OF THE EXISTING BRIDGE INDICATED ON THE PLANS IS FROM THE BEST INFORMATION E. L KELLY,JR. APU19765 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 C C COLUMN DOWEL DETAIL FOOTING DOWEL DETAIL FOOTING (TYP.) EXISTING CONCRETE9•"14 SPA. @ 1'-0" = 14'-0" FOOTING STRUT EXISTING CONCRETE FOOTING STRUT DOWEL DETAIL SECTION C-C NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET 2 OF 3 DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG 121+35.40 -TRK5- VMW PEK Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. 2 ' - 3 " 1 ' - 5 " E M B E D . VERTICAL DOWEL DETAIL CONCRETE TOP OF EXISTING BRIDGE AT WEST CARSON BLD 6 " 6"1'-0" (TYP.)(TYP.) ( T Y P . ) (TYP.)JOINT CONSTRUCTION JOINT (TYP.) CONSTRUCTION FOOTING EXISTING CONCRETE FOOTING (TYP.) PROPOSED CONCRETE B B FOOTING EXISTING CONCRETE 7 " 6 " FOOTING STRUT EXISTING CONCRETE SECTION B-B EXISTING COLUMNS AND FOOTINGS) FOR EMBEDMENT LENGTHS INTO (SEE HORIZONTAL DOWEL DETAIL EXISTING FOOTINGS) FOR EMBEDMENT LENGTHS INTO (SEE VERTICAL DOWEL DETAIL EXISTING COLUMNS AND FOOTINGS) FOR EMBEDMENT LENGTHS INTO (SEE HORIZONTAL DOWEL DETAIL NOTES: ADHESIVELY ANCHORED DOWEL 2'-3"1'-5" EMBED. CONCRETEFACE OF HORIZONTAL DOWEL DETAIL ADHESIVELY ANCHORED DOWEL BENT 3 CRASHWALL DETAILS 19 SPA. @ 1'-0" = 19'-0" COLUMN STRUT DOWEL DETAIL S-5 OVER NORFOLK SOUTHERN RR 9" 1'-5" 1 ' - 0 " 10" 1 ' - 3 " EMBED. DETAIL "A" 10 (TYP.) #6D1 #6D1 (TYP.) #6D2 (TYP.) #6D3 (TYP.) 1-16 1-16 UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL 6. 5. 4. 3. 2. 1. COLUMN STRUT EXISTING CONCRETE DETAIL FOR SPACING) (SEE COLUMN STRUT DOWEL #6D2 6" = 3'-0" 3 SPA. @ 1'-0" 6" = 3'-0" 3 SPA. @ 1'-0" COLUMN STRUT (TYP.) EXISTING CONCRETE #6D1 #6D1 FOOTING EXISTING CONCRETE FOOTING STRUT EXISTING CONCRETE 6'-10" 2'-5" 4 • " 1 ' - 2 " GROUT DOWEL IN PLACE CORE 1" • HOLES THROUGH STRUT, #6D3 (TYP.) BENT CAP EXISTING CONCRETE COLUMN EXISTING CONCRETE FOOTING EXISTING CONCRETE FOOTING STRUT EXISTING CONCRETE 6 " 1'-0" #6D1 (TYP.) SEE DETAIL "A" COLUMN STRUT EXISTING CONCRETE 15 S P A . @ 1 ' - 0 " = 15 ' - 0 " THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE PROPOSED DOWELS IS PREFERED. PROPOSED LOCATION. MOVING DOWEL IN LINE WITH OTHER PROPOSED DOWELS, DOWELS MAY BE MOVED UP TO 3" FROM WHEN EXISTING REINFORCEMENT IS IN CONFLICT WITH DEPTH. ADVANCING PILOT HOLE IN ‚" INCREMENTS UP TO A 4" BEFORE CHECKING FOR REINFORCEMENT. CONTINUE ADVANCE PILOT HOLES NO MORE THAN ‚" AT A TIME PILOT HOLES TO CHECK FOR EXISTING REINFORCEMENT. WITH THE PROPOSED DOWELS. THE CONTRACTOR WILL DRILL WILL ENCOUNTER EXISTING REINFORCEMENT IN CONFLICT IT IS STILL HIGHLY PROBABLE THAT THE CONTRACTOR EXISTING REBAR IS LESS LIKELY TO BE PLACED. HOWEVER, ADHESIVELY ANCHORED DOWELS HAVE BEEN LOCATED WHERE SPECIAL PROVISIONS. ADHESIVELY ANCHORED ANCHOR BOLTS OR DOWELS, SEE PROVISIONS. NO FIELD TESTING IS REQUIRED. FOR THE MANUFACTURER'S RECOMMENDATIONS AND THE SPECIAL ADHESIVELY ANCHORED DOWELS SHALL BE INSTALLED PER STANDING WATER. BE APPLIED TO SURFACES THAT HAVE VISIBLE OR APPROXIMATELY 100 PSI. BONDING COMPOUND SHALL NOT BOTTOM DISCHARGE PRESSURE VESSEL OPERATING AT APPLIED AS A SPRAY APPLICATION BY USE OF A BINKS IS FURTHER RECOMMENDED THAT BONDING COMPOUND BE ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. IT PRODUCTS LIST. BONDING SYSTEM SHALL BE APPLIED IN BODING SYSTEM SHALL BE LISTED ON THE NCDOT APPROVED MATERIAL WITH AN EPOXY BONDING COMPOUND. EPOXY NEW CONCRETE SHALL BE BONDED TO CLEAN SOUND POTABLE WATER. WITH A DETERGENT AND THE SURFACE WASHED WITH CLEAN DUST. GREASE AND OIL SHALL BE SCRUBBED AND REMOVED AIR CLEANED WITH OIL FREE AIR TO REMOVE ALL LOOSE EXPOSED SURFACE SHALL BE WASHED WITH CLEAN WATER OR REMOVED AND THAT A CLEAN SOUND SURFACE REMAINS. THE FOREIGN MATERIAL AND LOOSE OR UNSOUND CONCRETE IS EITHER WATERBLASTING OR WIRE BRUSHED SO THAT ALL NEW CONCRETE WILL BE BONDED SHALL BE CLEANED BY THE SURFACE OF THE EXISTING MATERIAL TO WHICH THE GRADE 60 AND SHALL BE SPACED AS SHOWN ON THE PLANS. DOWELS SHALL BE MADE OF DEFORMED BARS, ASTM A615, SPECIFIED IN AREMA SPECIFICATIONS, CHAPTER 8, PART 14. SURFACE PREPARATION AND ANCHORAGE SHALL BE AS E. L KELLY,JR. A PU19765 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET 3 OF 3 DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG 121+35.40 -TRK5- VMW PEK Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. BRIDGE AT WEST CARSON BLD BENT 3 CRASHWALL DETAILS S-6 OVER NORFOLK SOUTHERN RR 10 1-16 1-16 FOOTING STRUT EXISTING CONCRETE 2" CL. (TYP.) #5V1 BACK FACE #5V2 COLUMN CONCRETE EXISTING 3 " 18 - # 5 "H " B A R S FACE FRONT 3 " 1 0 ' - 0 " M I N . ( F I E L D V E R I F Y ) T O T O P O F R A I L 3" (TYP.) 4 SPA. @ 6" CTS. 2'-6" #5S1 2 " C L . ( T Y P . ) #5L1 #5T1 #5T1 2 ' - 0 " 2 ' - 2 " M I N . S P L I C E (T Y P . ) # 5 V 1 W I T H # 5 L 1 4" (TYP.) 3 SPA. @ 1'-0" MAX. 8-#5 "T" BARS (4 EA. FACE) 4'-0" (TYP.) 3" CL. (TYP.) 3 " C L . ( T Y P . ) SECTION D-D D D EXISTING CONCRETE COLUMN (TYP.) 3"3" 6-#5V1 (3 EA. FACE) & 3-#5U1 3"3" 6-#5V1 (3 EA. FACE) & 3-#5U1 #5V1 #5V1 #5V1 #5V1 6 " 2 ' - 0 "| 2" CL. (TYP.) 2 " C L . (T Y P . ) 2 " C L . (T Y P . ) FOOTING (TYP.) EXISTING CONCRETE (TYP.) #5L1 15'-5" #5T2 2" CL. (TYP.) 3 " C L . (T Y P . ) 15'-5" 6"6" 15'-0" (DOWEL BARS NOT SHOWN FOR CLARITY) ELEVATION EXISTING CONCRETE FOOTING (TYP.) 8'-0"|8'-0"|15'-0"8'-0"|8'-0"|15'-5"15'-5" EXISTING CONCRETE COLUMN (TYP.) 11"14 SPA. @ 1'-0" 15-#5L1 (SPLICE WITH #5V1) 6"6"14 SPA. @ 1'-0" 15-#5L1 (SPLICE WITH #5V1) 11"14 SPA. @ 1'-0" 15-#5L1 (SPLICE WITH #5V1) 2" CL. (TYP.) 2" CL. (TYP.) 2 ' - 6 " 2 " C L . ( T Y P . ) 2'- 6 " 3'-0" MIN. SPLICE #5H1 (2 BAR RUN) WITH #5H2 #5H2 #5H2 #5H3 #5H5 #5H4 #5H6 #5H7 (FOOTING REINFORCING AND DOWEL BARS NOT SHOWN FOR CLARITY) PLAN #5T3 #5T2 (TYP. EA. END) #5U2 BAR TYPE 5 ' - 0 " 1 ' - 0 " 2'-3" 2'-2" REINFORCING SCHEDULE BAR NO.SIZE TYPE LENGTH WEIGHT BAR NO.SIZE TYPE LENGTH WEIGHT PLANS PRELIMINARY UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL 2•"2•" 32-#5T1 (16 EA. FACE)30-#5T1 (15 EA. FACE) 2•"2•" 32-#5T1 (16 EA. FACE) 4-#5 "H" BARS 4 2 - # 5 H 1 @ 1 ' - 0 " M A X . S P A . 3 ' - 0 " M I N . S P L I C E (2 B A R R U N ) W I T H 4"4" 1'-0" (TYP.)1'-0" (TYP.) 1'-0" 3-#5V1 (TYP. EXT. COLUMNS) 3 ' - 0 " M I N . S P L I C E (2 B A R R U N ) ) W I T H 3 " 3 " 3 " 2 1 - # 5 U 1 @ 1 ' - 0 " M A X . S P A . (T Y P . E A . E N D ) 2 SPA. @ 1'-0" MAX. 20 SPA. @ 1'-0"2 SPA. @ 1'-0" MAX. 2 SPA. @ 1'-0" MAX. 15 SPA. @ 1'-0"14 SPA. @ 1'-0"15 SPA. @ 1'-0" 77'-10" 6"6" (TYP.) FOOTING STRUT EXISTING CONCRETE 3 " 2 1 - # 5 H 3 @ 1 ' - 0 " M A X . S P A . 3 " 2 1 - # 5 H 7 @ 1 ' - 0 " M A X . S P A . 21-#5S1 (TYP. BETWEEN COLUMNS) 21-#5V1 (FRONT FACE), 21-#5V2 (BACK FACE), & REINFORCING SCHEDULE 2'-0" 8 " 1 ' - 6 " 2'-2" 1 ' - 6 " COLUMN STRUT (TYP.) EXISTING CONCRETE STRUT COLUMN CONCRETE EXISTING NOTES: 2. 1. MAINTAIN 2" CLEARANCE. FIELD BEND #5H1 AT FRONT CORNER OF CRASHWALL AS NECESSARY TO TO PROVIDE 2" CLEARANCE TO THE EXISTING CONCRETE COLUMN STRUT. FIELD CUT #5V2 AND #5 "H" BARS AT THE TOP OF CRASHWALL AS NECESSARY 17 S P A . @ 1 ' - 0 " 4 2 - # 5 H 1 @ 1 ' - 0 " M A X . S P A . 18 - # 5 H 2 @ 1 ' - 0 " S P A . 18 - # 5 H 2 @ 1 ' - 0 " S P A . 18 - # 5 H 2 @ 1 ' - 0 " S P A . FIELD BEND #5H1 THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE E. L KELLY,JR. APU19765 2 ALL BAR DIMENSIONS ARE OUT TO OUT 3 1 H1 #5 STR.40'-5"42 1,770 H2 #5 STR.20'-2"66 H3 #5 STR.1'-11"24 H4 #5 STR.1'-9"1 H5 #5 STR.1 48 2 1'-7"2 H6 #5 STR.1 1'-5"1 H7 #5 STR.21 1'-4"29 TOTAL REINFORCING STEEL = L1 #5 2 7'-0"329 S1 #5 3 4'-4"285 45 D3 STR.6'-10"#690 924 D2 3'-3"#660 2931 #5 STR.T1 3'-6"188 #5 STR.T2 498 T3 #5 STR.14'-6"24216 686 14'-11"32 D1 STR.1,4102563'-8"#6 63 4 V1 #5 STR.1,832 V2 STR.#5 17'-2" 85 63 U1 #5 4 5'-2"25948 20'-8" 1,388 1,128 11,126 LBS. REINFORCING STEEL LBS. CU. YARDS 11,126 155.3CLASS A CONCRETE BILL OF MATERIAL BENT 3 AT STA. 121+35.40 -TRK5- FOUNDATION EXCAVATION FOR LUMP SUM LUMP SUMBENT 3 AT STA. 121+35.40 -TRK5- TEMPORARY RAILROAD SHORING FOR CONCRETE REPAIRS EPOXY RESIN INJECTION CF. LF. 2.0 6.2 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 (TYP.)COLUMNS CONCRETE{ EXISTING FOOTING (TYP.) EXISTING CONCRETE FOOTINGS PROPOSED { EXISTING & BENT CAP EXISTING CONCRETE FOOTING (TYP.) PROPOSED CONCRETE FOOTING (TYP.) EXISTING CONCRETE A A ELEVATION BENT 4 CRASHWALL NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET 1 OF 3 DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG 121+35.40 -TRK5- VMW PEK Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. EL. 719.3 4'-11"2'-7"2'-6" BENT CAP EXISTING CONCRETE COLUMN EXISTING CONCRETE CRASHWALL PROPOSED CONCRETE FOOTING PROPOSED CONCRETE 8'-0"13'-0‚"8'-0"12'-8"8'-0"13'-0‚"8'-0" 4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0" 1 " 10 ' - 0 " 5 ' - 0 " 5 ' - 0 "2 ' - 6 " PLAN CRASHWALL PROPOSED CONCRETE PILES (TYP.) EXISTING TIMBER 4'-0"4'-0" 10'-0" SECTION A-A CRASHWALLCONCRETE PROPOSED FACE OF CONCRETE CRASHWALL PROPOSED BACK OF (TYP.) FOOTING CONCRETE PROPOSED (TYP.) PILES TIMBER EXISTING PLAN & ELEVATION BRIDGE AT WEST CARSON BLD FOOTING STRUT EXISTING CONCRETE (FOR DOWEL DETAILS SEE SHEET S-8) S-7 OVER NORFOLK SOUTHERN RR NOTES: 3. 2. 1. 10 1-16 1-16 (SPAN D SIDE) RESIN INJECTION 1.0 LF. EPOXY (SPAN E SIDE) RESIN INJECTION 4.5 LF. EPOXY (COLUMN 2 ONLY) RESIN INJECTION 1.0 LF. EPOXY (COLUMN 3 ONLY) 0.5 SF. CONCRETE REPAIR (COLUMN 4 ONLY) RESIN INJECTION 1.5 LF. EPOXY (COLUMN 1 ONLY) RESIN INJECTION 3.0 LF. EPOXY RESIN INJECTION 1.5 LF. EPOXY CONCRETE REPAIR 0.5 SF. (TYP.)COLUMN CONCRETE EXISTING COLUMN STRUT (TYP.) EXISTING CONCRETE RESIN INJECTION 1.0 LF. EPOXY RESIN INJECTION 3.0 LF. EPOXY DETAIL SEE SHEET S-8 FOR FOOTING DOWEL SHEET S-8 DOWEL DETAIL SEE FOR FOOTING STRUT (TYP.) FOOTING STRUT EXISTING CONCRETE (LOOKING EAST) UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL COLUMN STRUT EXISTING CONCRETE 2 ' - 0 " 2'-6" 10" (TOP) 4" (BOT.) DETAIL SEE SHEET S-8 FOR COLUMN DOWEL NOT SHOWN FOR CLARITY) (EXISTING CONCRETE COLUMN STRUT THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE REPAIRS BEFORE CONSTRUCTING CRASH WALLS. SEE SHEET S-10 FOR DETAILS. PERFORMED ON THE EXISTING BENT 4 OF THE BRIDGE. COMPLETE CONCRETE ON THE PLANS AND AS DIRECTED BY THE ENGINEER. REPAIRS WILL ONLY BE PERFORM CONCRETE REPAIRS AND EPOXY RESIN INJECTION WHERE INDICATED RAIL. TOP OF CRASHWALL SHALL BE A MINIMUM OF 10'-0" ABOVE ADJACENT TOP OF THE ACTUAL CONDITIONS AT THE PROJECT SITE. BETWEEN THE EXISTING BRIDGE SUBSTRUCTURE SHOWN ON THE PLANS AND FOR ANY DELAYS OR ADDITIONAL COST INCURRED BASED ON DIFFERENCES HAVE NO CLAIM WHATSOEVER AGAINST THE DEPARTMENT OF TRANSPORTATION SHOWN FOR THE CONVENIENCE OF THE CONTRACTOR, THE CONTRACTOR SHALL FROM THE BEST INFORMATION AVAILABLE. SINCE THIS INFORMATION IS THE SUBSTRUCTURE OF THE EXISTING BRIDGE INDICATED ON THE PLANS IS FOR GROUT FOR STRUCTURED, SEE SPECIAL PROVISIONS. FOR FALSEWORK AND FORMWORK, SEE SPECIAL PROVISIONS. FOR SUBMITAL OF WORKING DRAWINGS, SEE SPECIAL PROVISIONS. 6. 5 4. E. L KELLY,JR. APU19765 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 C C COLUMN DOWEL DETAIL FOOTING EXISTING CONCRETE 6" 3 SPA. @ 1'-0" = 3'-0" 6" 3 SPA. @ 1'-0" = 3'-0" 9 " 6 " FOOTING (TYP.) EXISTING CONCRETE11 SPA. @ 1'-0" = 11'-0" FOOTING STRUT EXISTING CONCRETE FOOTING STRUT DOWEL DETAIL NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET 2 OF 3 DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG 121+35.40 -TRK5- VMW PEK Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. 2 ' - 3 " 1 ' - 5 " E M B E D . VERTICAL DOWEL DETAIL CONCRETE TOP OF EXISTING CONCRETEFACE OF HORIZONTAL DOWEL DETAIL 1'-0" COLUMN EXISTING CONCRETE 1 0 S P A . @ 1 ' - 0 " = 10 ' - 0 " FOOTING EXISTING CONCRETE PILES (TYP.) EXISTING TIMBER FOOTING STRUT EXISTING CONCRETE PILES (TYP.) EXISTING TIMBER FOOTING STRUT EXISTING CONCRETE BRIDGE AT WEST CARSON BLD FOOTING DOWEL DETAIL JOINT (TYP.) CONSTRUCTION FOOTING EXISTING CONCRETE FOOTING (TYP.) PROPOSED CONCRETE B B 6" (TYP.) 1'-0" (TYP.) 6 " (T Y P . ) (TYP.)JOINT CONSTRUCTION SECTION B-B EXISTING COLUMNS AND FOOTINGS) FOR EMBEDMENT LENGTHS INTO (SEE HORIZONTAL DOWEL DETAIL EXISTING COLUMNS AND FOOTINGS) FOR EMBEDMENT LENGTHS INTO (SEE HORIZONTAL DOWEL DETAIL ADHESIVELY ANCHORED DOWEL ADHESIVELY ANCHORED DOWEL 2'-3"1'-5" EMBED. FOOTING EXISTING CONCRETE FOOTING STRUT EXISTING CONCRETE SECTION C-C 6'-10" 2'-5" 4 • " EXISTING FOOTINGS) FOR EMBEDMENT LENGTHS INTO (SEE VERTICAL DOWEL DETAIL BENT 4 CRASHWALL DETAILS S-8 OVER NORFOLK SOUTHERN RR 9 " 1'-4" 10 1-16 1-16 #6D1 (TYP.) (TYP.) #6D1 (TYP.) #6D3 #6D1 (TYP.) COLUMN STRUT EXISTING CONCRETE SEE DETAIL "A" 1'-5" 1 ' - 0 " 10" 1 ' - 3 " EMBED. DETAIL "A" COLUMN STRUT EXISTING CONCRETE DETAIL FOR SPACING) (SEE COLUMN STRUT DOWEL #6D2 17 SPA. @ 1'-0" = 17'-0" COLUMN STRUT DOWEL DETAIL 7" #6D2 (TYP.) COLUMN STRUT (TYP.) EXISTING CONCRETE NOTES: 6. 5. 4. 3. 2. 1. UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL #6D1 #6D1 1 ' - 2 " GROUT DOWEL IN PLACE CORE 1" • HOLES THROUGH STRUT, #6D3 (TYP.) THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE PROPOSED DOWELS IS PREFERED. PROPOSED LOCATION. MOVING DOWEL IN LINE WITH OTHER PROPOSED DOWELS, DOWELS MAY BE MOVED UP TO 3" FROM WHEN EXISTING REINFORCEMENT IS IN CONFLICT WITH DEPTH. ADVANCING PILOT HOLE IN ‚" INCREMENTS UP TO A 4" BEFORE CHECKING FOR REINFORCEMENT. CONTINUE ADVANCE PILOT HOLES NO MORE THAN ‚" AT A TIME PILOT HOLES TO CHECK FOR EXISTING REINFORCEMENT. WITH THE PROPOSED DOWELS. THE CONTRACTOR WILL DRILL WILL ENCOUNTER EXISTING REINFORCEMENT IN CONFLICT IT IS STILL HIGHLY PROBABLE THAT THE CONTRACTOR EXISTING REBAR IS LESS LIKELY TO BE PLACED. HOWEVER, ADHESIVELY ANCHORED DOWELS HAVE BEEN LOCATED WHERE SPECIAL PROVISIONS. ADHESIVELY ANCHORED ANCHOR BOLTS OR DOWELS, SEE PROVISIONS. NO FIELD TESTING IS REQUIRED. FOR THE MANUFACTURER'S RECOMMENDATIONS AND THE SPECIAL ADHESIVELY ANCHORED DOWELS SHALL BE INSTALLED PER STANDING WATER. BE APPLIED TO SURFACES THAT HAVE VISIBLE OR APPROXIMATELY 100 PSI. BONDING COMPOUND SHALL NOT BOTTOM DISCHARGE PRESSURE VESSEL OPERATING AT APPLIED AS A SPRAY APPLICATION BY USE OF A BINKS IS FURTHER RECOMMENDED THAT BONDING COMPOUND BE ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. IT PRODUCTS LIST. BONDING SYSTEM SHALL BE APPLIED IN BODING SYSTEM SHALL BE LISTED ON THE NCDOT APPROVED MATERIAL WITH AN EPOXY BONDING COMPOUND. EPOXY NEW CONCRETE SHALL BE BONDED TO CLEAN SOUND POTABLE WATER. WITH A DETERGENT AND THE SURFACE WASHED WITH CLEAN DUST. GREASE AND OIL SHALL BE SCRUBBED AND REMOVED AIR CLEANED WITH OIL FREE AIR TO REMOVE ALL LOOSE EXPOSED SURFACE SHALL BE WASHED WITH CLEAN WATER OR REMOVED AND THAT A CLEAN SOUND SURFACE REMAINS. THE FOREIGN MATERIAL AND LOOSE OR UNSOUND CONCRETE IS EITHER WATERBLASTING OR WIRE BRUSHED SO THAT ALL NEW CONCRETE WILL BE BONDED SHALL BE CLEANED BY THE SURFACE OF THE EXISTING MATERIAL TO WHICH THE GRADE 60 AND SHALL BE SPACED AS SHOWN ON THE PLANS. DOWELS SHALL BE MADE OF DEFORMED BARS, ASTM A615, SPECIFIED IN AREMA SPECIFICATIONS, CHAPTER 8, PART 14. SURFACE PREPARATION AND ANCHORAGE SHALL BE AS E. L KELLY,JR. APU19765 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET 3 OF 3 DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG 121+35.40 -TRK5- VMW PEK Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. BRIDGE AT WEST CARSON BLD BENT 4 CRASHWALL DETAILS S-9 OVER NORFOLK SOUTHERN RR 10 1-16 1-16 COLUMN (TYP.) EXISTING CONCRETE CRASHWALL PROPOSED CONCRETE PILES (TYP.) EXISTING TIMBER FOOTING STRUT EXISTING CONCRETE 2" CL. (TYP.) FACE BACK 3" (TYP.) 4 SPA. @ 6" CTS. 2'-6" #5T1 #5T1 2 ' - 2 " M I N . S P L I C E (T Y P . ) # 5 V 1 W I T H # 5 L 1 4" (TYP.) 3 SPA. @ 1'-0" MAX. 8-#5 "T" BARS (4 EA. FACE) 4'-0" (TYP.) 3" CL. (TYP.) SECTION D-D #5L1 2 ' - 0 " 3 " C L . (T Y P . ) 1 0 ' - 0 " M I N . ( F I E L D V E R I F Y ) T O T O P O F R A I L FACE FRONT 3"3"18 SPA. @ 1'-0" MAX. 3"3" 3 SPA. @ 1'-0" MAX. 2 " C L . (T Y P . ) 3 " 2 ' - 0 "| FOOTING (TYP.) EXISTING CONCRETE 2" CL. (TYP.) (TYP.) #5L1 6"6" 26-#5T1 (13 EA. FACE) 13'-0‚" #5T2 2 " C L . (T Y P . ) 3 " C L . (T Y P . ) 2" CL. (TYP.) #5T2 4"4" 26-#5T1 (13 EA. FACE) 12 SPA. @ 1'-0" 12'-8" #5T3 D D (DOWEL BARS NOT SHOWN FOR CLARITY) ELEVATION 8'-0"|13'-0‚"8'-0"|12'-8"8'-0"|13'-0‚"8'-0"| 5‚" 13-#5L1 (SPLICE WITH #5V1) 12 SPA. @ 1'-0" MAX.5‚" 13-#5L1 (SPLICE WITH #5V1) 12 SPA. @ 1'-0" MAX. 13-#5L1 (SPLICE WITH #5V1) 12 SPA. @ 1'-0" MAX. PILES (TYP.) EXISTING TIMBER FOOTING (TYP.) EXISTING CONCRETE EXISTING CONCRETE COLUMN (TYP.) 2 ' - 6 " 2 " C L . ( T Y P . ) (TYP. EA. END) #5U1 2" CL. (TYP.) 2" CL. (TYP.) 3'-0" MIN. SPLICE #5H1 (2 BAR RUN) WITH (T Y P . ) (FOOTING REINFORCING AND DOWEL BARS NOT SHOWN FOR CLARITY) PLAN 3 " 3 ' - 0 " M I N . S P L I C E (2 B A R R U N ) W I T H #5V1 #5V2 COLUMN CONCRETE EXISTING 4-#5 "H" BARS 2 " C L . (T Y P . ) 1 4 - # 5 "H " B A R S 1 3 S P A . @ 1 ' - 0 "STRUT COLUMN CONCRETE EXISTING #5S1 3 " #5V1 1'-0" (TYP.)1'-0" (TYP.) #5V1 COLUMN STRUT (TYP.) EXISTING CONCRETE & 19-#5S1 (TYP. BETWEEN COLUMNS) 19-#5V1 (FRONT FACE), 19-#5V2 (BACK FACE), 4-#5U1 8-#5V1 (4 EA. FACE) & 1'-0" 3-#5V1 (TYP. EXT. COLUMNS) 2 SPA. @ 1'-0" MAX. 3" 3 SPA. @ 1'-0" MAX. 4-#5U1 8-#5V1 (4 EA. FACE) & 3" (T Y P . E A . E N D ) 17 - # 5 U 1 @ 1 ' - 0 " M A X . S P A . #5V1 #5V1 3 ' - 0 " M I N . S P L I C E (2 B A R R U N )) W I T H 3 4 - # 5 H 1 @ 1 ' - 0 " M A X . S P A . 3 " 1 4 - # 5 H 2 @ 1 ' - 0 " S P A . 3 " 1 4 - # 5 H 2 @ 1 ' - 0 " S P A . 3 " 1 4 - # 5 H 2 @ 1 ' - 0 " S P A . 3 " 1 7 - # 5 H 3 @ 1 ' - 0 " S P A . 3 " 1 7 - # 5 H 3 @ 1 ' - 0 " S P A . 12 SPA. @ 1'-0"6"6" 26-#5T1 (13 EA. FACE) 13'-0‚" 12 SPA. @ 1'-0" 70'-8•" #5H2 #5H2 #5H2 #5H3 #5H3 UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL NOTES: 1. TO THE EXISTING CONCRETE COLUMN STRUT. CRASHWALL AS NECESSARY TO PROVIDE 2" CLEARANCE FIELD CUT #5V2 AND #5 "H" BARS AT THE TOP OF REINFORCING SCHEDULE BAR NO.SIZE TYPE LENGTH WEIGHT BAR TYPE 5 ' - 0 " 1 ' - 0 " 2'-3" 2'-2" 2'-0" 8 " 1 ' - 6 " 2'-2" 1 ' - 6 " REINFORCING SCHEDULE BAR NO.SIZE TYPE LENGTH WEIGHT 3 4 - # 5 H 1 @ 1 ' - 0 " S P A . (TYP.) FOOTING STRUT EXISTING CONCRETE 7"4"4"7" THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE E. L KELLY,JR. APU19765 H1 #5 STR.36'-8"34 1,300 H2 #5 STR.54 H3 #5 STR.2'-0"42 L1 #5 2 7'-0"285 S1 #5 3 4'-4"258 39 D3 STR.6'-10"#672 739 D2 3'-3"#654 2641 D1 STR.1,1902163'-8"#6 57 2 ALL BAR DIMENSIONS ARE OUT TO OUT 3 1 4 17'-10"1,004 88 TOTAL REINFORCING STEEL = #5 STR.T1 3'-6"156 #5 STR.T2 417 T3 #5 STR.12'-2"20316 569 32 V1 #5 STR.1,428 V2 STR.#5 13'-2" 83 57 783 U1 #5 4 5'-2"26950 8,797 LBS. 12'-6" 16'-6" REINFORCING STEEL LBS. CU. YARDS 8,797 112.6CLASS A CONCRETE BILL OF MATERIAL BENT 4 AT STA. 121+35.40 -TRK5- FOUNDATION EXCAVATION FOR LUMP SUM CONCRETE REPAIRS EPOXY RESIN INJECTION CF. LF. 0.5 11.0 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 STRUCTURE REPAIR NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG VMW PEK Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. TYPICAL SUBSTRUCTURE REPAIR DETAILS SECTION BENT CAP DELAMINATION FACE SPALL OR ELEVATION FACE REPAIR ( MI N.) 2" CORNER REPAIR DEPTH WILL NOT DAMAGE EXISTING REINFORCING STEEL. REMOVE SURFACE CONCRETE TO VERIFY THAT SAWCUT TO EXISTING REINFORCEMENT. CONTRACTOR SHALL •". THI DEPTH SHALL BE REDUCED TO PREVENT DAMAGE CONTRACTOR SHALL SAW CUT TO A MAXIUM DEPTH OF NOTE: NOTES: BRIDGE AT I-277 & WEST CARSON BLD 121+35.40 -TRK5- 118+95.67 -TRK5- & 1-16 1-16 S-10 10 UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL PLANS PRELIMINARY SPECIAL PROVISIONS) AND REPAIR (SEE TO SOUND CONCRETE REMOVE 1" BEHIND REBAR STIRRUPS WITH 9" MIN. EMBED. CENTERED BETWEEN EXISTING PROPOSED #5 DOWEL (TYP.) (SEE NOTE) SURFACE •" SAW CUT BARS (TYP.) EXISTING (SEE NOTE) (TYP.) •" SAW CUT (M I N . ) 2 " 2" (TYP.) THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE FOR EPOXY RESIN INJECTION, SEE SPECIAL PROVISIONS. FOR CONCRETE REPAIRS, SEE SPECIAL PROVISIONS. ACHIEVE CLEARANCE. TO REINFORCING STEEL. REPAIRED AREAS MAY BE BUILT OUT TO SUBSTRUCTURE REPAIRS SHALL PROVIDE A MINIMUM OF 2" CLEAR COVER REINFORCING STEEL SHALL BE GRADE 60. SYSTEM. SPECIFIED BY THE MANUFACTURER OF THE EPOXY ADHESIVE BONDING CONCRETE AND MAY BE ADJUSTED BASED ON THE MINIMUM EMBEDMENT DOWEL LENGTH SHALL BE BASED ON A 9" EMBEDMENT INTO EXISTING DIRECTED BY THE ENGINEER AND COMPLETED AT NO ADDITIONAL COSTS. CONCRETE REMOVAL PROCESS. REPAIRS TO DAMAGED BARS SHALL BE THE ENGINEER SHALL BE NOTIFIED OF ANY BARS DAMAGED DURING THE DIMENSIONS PRIOR TO MAKING REPAIRS. CONTRACTOR SHALL DETERMINE ACTUAL SPALL, CRACK, AND DELAMINATION SPALL, CRACK, AND DELAMINATION DIMENSIONS SHOWN ARE APPROXIMATE. THAT A CONCRETE REPAIR IS NECESSARY. FOR CRACKS REQUIRING EPOXY RESIN INJECTION, SOUNDING MAY PROVE CONCRETE REPAIRS. CONCRETE SHALL BE SOUNDED TO DETERMINE THE EXTENT OF ALL 9. 8. 7. 6. 5. 4. 3. 2. 1. E. L KELLY,JR. A PU19765 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 DRAWN BY : CHECKED BY : DATE : DATE : Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. 6" R. BAR DIMENSIONS ARE OUT TO OUT P-2918F MECKLENBURG 140+14.92 -TRK5- VMW PEK 1-16 1-16 CONCRETE BOX CULVERT 6 FT. X 6 FT. DOUBLE BARREL DESIGN FILL-----------------7.2 FT. CONCRETE IN CULVERTS TO BE POURED IN THE FOLLOWING ORDER: THE RESIDENT ENGINEER SHALL CHECK THE LENGTH OF CULVERT BEFORE STAKING IT OUT TO MAKE CERTAIN THAT IT WILL PROPERLY TAKE CARE OF THE FILL. EMBEDDED IN BARREL ARE SHOWN ON WING SHEET. STEEL IN THE BOTTOM SLAB MAY BE SPLICED AT THE PERMITTED CONSTRUCTION SHALL BE PAID FOR BY THE CONTRACTOR. IN THE INTERIOR FACE OF EXTERIOR WALL AND BOTH FACES OF INTERIOR WALLS IN THE SPLICE LENGTH CHART SHOWN ON THE PLANS. EXTRA WEIGHT OF STEEL DUE TO THE SPLICES SHALL BE PAID FOR BY THE CONTRACTOR. OF ALL VERTICAL WALLS. HEIGHT FOLLOWED BY ROOF SLAB AND HEADWALLS. 2. THE REMAINING PORTIONS OF THE WALLS AND WINGS FULL DIMENSIONS FOR WING LAYOUT AS WELL AS ADDITIONAL REINFORCING STEEL AT THE CONTRACTOR'S OPTION HE MAY SUBMIT, TO THE ENGINEER FOR APPROVAL, DESIGN AND DETAIL DRAWINGS FOR A PRECAST REINFORCED CONCRETE BOX CULVERT IN LIEU OF THE CAST-IN-PLACE CULVERT SHOWN ON THE PLANS. THE DESIGN SHALL PROVIDE THE SAME SIZE AND NUMBER OF BARRELS AS USED ON THE CAST-IN-PLACE DESIGN. FOR OPTIONAL PRECAST REINFORCED CONCRETE BOX CULVERT, SEE SPECIAL PROVISIONS. AT THE CONTRACTOR'S OPTION, HE MAY SPLICE THE VERTICAL REINFORCING STEEL 3" ~ WEEP HOLES INDICATED TO BE IN ACCORDANCE WITH THE SPECIFICATIONS. JOINT AT THE CONTRACTOR'S OPTION. EXTRA WEIGHT OF STEEL DUE TO THE SPLICES 1. WING FOOTINGS AND FLOOR SLAB INCLUDING 4" LOCATION SKETCH 1 4 0 + 0 0 { -TRK5- STA. 140+14.92 -TRK5- 70'-0" 45'-0"25'-0" 76°-34'-26" { CULVERT PROFILE ALONG { CULVERT BAR NO.SIZE TYPE LENGTH WEIGHT 67 #6 STR 14'-2"A100 1,426 2 #6 STR 9'-11"A101 2 #6 STR 5'-9"A102 30 17 #6 STR 14'-2"A200 2 #6 STR 9'-11"A201 2 #6 STR 5'-9"A202 30 17 #6 STRA300134 14'-2"2,851 #6 STRA301 12'-0"2 36 #6 STRA3022 9'-11"30 #6 STRA3032 7'-10"24 #6 STRA3042 5'-9"17 #6 STRA3052 3'-8"11 A103 2 #6 STR 1'-7"5 A203 2 #6 STR 1'-7"5 A306 2 #6 STR 1'-7"5 #8 STRA400 14'-2" STRA401 12'-0"2 64 STRA4022 9'-11"53 STRA4032 7'-10"42 STRA4042 5'-9"31 STRA4052 3'-8"20 A406 2 STR 1'-7"9 #8 #8 #8 #8 #8 #8 9 •"VERTICAL LEG REINFORCING STEEL ABOVE LOWER WALL CONSTRUCTION JOINT. THE SPLICE LENGTH SHALL BE AS PROVIDED 1 2'-2" 5'-10"#5A1560 1 3,407 STR 7'-7"#5B1336 2,658 STR 5'-4"#5B2168 935 STR 24'-6"#4C1186 3,044 STR 14'-6"#5G18 121 STR 14'-6"#8S212 465 REINFORCING STEEL CLASS A CONCRETE LBS CY BAR TYPE 21,848 FOR CULVERT BILL OF MATERIAL NOTES: BAR SPLICE LENGTH CHART SPLICE LENGTHSIZE #6 2'-9" #5B1 2'-2" #4C1 1'-9" CLASS A CONCRETE BARREL @ WING ETC. BARREL TOTAL CY/FT C.Y. C.Y. LBS. LBS. WINGS ETC.LBS. C.Y. TOTAL TOTAL STRUCTURE QUANTITIES 17.2 132.0 21,848 934 22,782 DESIGN DISCHARGE FREQUENCY OF DESIGN FLOOD DESIGN HIGH WATER ELEVATION DRAINAGE AREA BASIC DISCHARGE (Q100) HYDRAULIC DATA = 100 YEARS = 2:1 GRADE DATA GRADE PT. ELEV. @ 140+14.92 -TRK5-= 698.52 = 484.0 C.F.S. = 691.05 = 80.60 AC. = 691.05 BED ELEV. @ STA. 140+14.92 -TRK5-= 684.90 FILL SLOPES UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL 2 ' - 1 0 • " FOR OTHER DESIGN DATA AND NOTES SEE STANDARD NOTES SHEET. ASSUMED LIVE LOAD ----------COOPER E80. SAMPLE, PLUS A MINIMUM LAP SPLICE OF THIRTY BAR DIAMETERS. MUST THEN BE SPLICED WITH REPLACEMENT BARS OF THE SIZE AND LENGTH OF THE SAMPLES OF EACH SIZE BAR USED. THE BARS FROM WHICH THE SAMPLES ARE TAKEN PROJECTS REQUIRING OVER 400 TONS OF REINFORCING STEEL, TWO 30 INCH REINFORCING STEEL, ONE 30 INCH SAMPLE OF EACH SIZE BAR USED, AND FOR REINFORCING STEEL AS FOLLOWS: FOR PROJECTS REQUIRING UP TO 400 TONS OF THE CONTRACTOR SHALL PROVIDE INDEPENDENT ASSURANCE SAMPLES OF CULVERT EXCAVATION LUMP SUM MATERIAL FOUNDATION CONDITIONING TON72.0 A200 A400 #8 4'-11" BASIC HIGH WATER ELEVATION OVERTOPPING FLOOD ELEVATION = >100 YEARS = 698.37 OVERTOPPING DISCHARGE FREQUENCY OF OVERTOPPING FLOOD OVERTOPPING FLOOD DATA POND DETENTION POND DETENTION FLOW FLOW 6'x6' CULVERT PROP. DBL. PROVISIONS. UTILITY PLANS AND SPECIAL FOR UTILITY INFORMATION, SEE C HA R L O TT E BM: NCGS (RV106) RIVET ELEV. = 684.54. SEE TOPO SHEET FOR LOCATION. { -TRK5- SHEET 1 OF 4 THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE = 484.0 C.F.S. = 1178.6 C.F.S. FOR CRANE SAFETY, SEE SPECIAL PROVISIONS. FOR GROUT FOR STRUCTURES, SEE SPECIAL PROVISIONS. FOR FALSEWORK AND FORMWORK, SEE SPECIAL PROVISIONS. FOR SUBMITAL OF WORKING DRAWINGS, SEE SPECIAL PROVISIONS. STA. 140+14.92 FLOW FLOW PROP. MAINT. RD. 67 1,426 5,069134 114.8 114.81.64 6'-6"35'-0"25'-0"7'-0" 70'-0" EL. 702.9|EL. 706.4| EL. 706.6| EL. 702.6| EL. 702.5| 10'-0" EL. 703.3| S-11 14 E. L KELLY,JR. A PU19765 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 2 ' - 6 " 2 ' - 6 " 1'-3" CONST. JT. 9 " CONST. JT. 3" 3" 3 " CULVERT SECTION NORMAL TO ROADWAY 3 " 6 " 6 " A 10 1 A 10 0 W1 W2 BOTTOM OF ROOF SLAB BOTTOM OF ROOF SLAB TOP OF FLOOR SLAB { CULVERT 8 " TOP OF FLOOR SLAB 6 " PART PLAN - FLOOR SLABPART PLAN - ROOF SLAB END ELEVATION NORMAL TO SKEW UPSTREAM END ONLY W2 W1 6" 6 " 4-#5 G1 BARS 6 " BOTTOM OF FLOOR SLAB 2 " CL. 6 " E A C H F A C E S T A G G E R E D 2 " 6 " SKEW TRIANGLE STREAM FACE FILL FACE A 2 0 0 O R A 4 0 0 A 2 0 1 O R A 4 0 1 EACH FACE STAGGERED IN INTERIOR WALL INTERIOR WALLEXTERIOR WALL STREAM FACE O R A 3 0 1 O R A 3 0 0 TOP OF ROOF SLAB TOP OF ROOF SLAB 1 0 ' ' 1 0 ' ' { -TRK5- STA. 140+14.92 -TRK5- NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET 2 OF 4 DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG 140+14.92 -TRK5- VMW PEK 1-16 1-16 Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. #5 B1 BARS @ 10" CTS. 10" 10" 3-#8 S2 BARS @ 5" CTS. #8 A401 BARS ETC. @ 6" CTS.6"#8 A400 BARS @ 6" CTS. -BOTTOM OF FLOOR SLAB #5 A1 BARS @ 6" CTS.- CORNER BARS EACH EXTERIOR WALL (SEE BARREL SECTION) @ 5" CTS. 3 #8 S2 BARS ROOF SLAB BOTTOM OF 13 '- 2 Š " I N S I D E F A C E S (S E E B A R R E L S E C T I O N ) # 4 C 1 B A R S IN HEADWALL @ 3" CTS. #6 A300 BARS @ 6" CTS.#6 A301 BARS ETC. @ 6" CTS.6" #5 B1 BARS @ 10" CTS. #5 B2 BARS @ 10" CTS. #5 A1 BARS @ 6" CTS. CORNER BARS EA. EXTERIOR WALL (SEE BARREL SECTION) (S E E B A R R E L S E C T I O N ) # 4 C 1 B A R S 76°-34'-26" 103°-25'-34" @ 5" CTS. 3-#8 S2 BARS ROOF SLAB BOTTOM OF FILL SLOPE 2 :1 (TYP.) (TYP.) FOR 2:1 FILL WING SLOPE @ 3" CTS 4-#5 G1 BARS 3-#8 S2 BARS 1 ' - 0 " CONCRETE BOX CULVERT 6 FT. X 6 FT. DOUBLE BARREL A S S HO W N I N T Y P I C A L # 4 C 1 B A R S @ 2 ' - 0 " C T S . #5 B1 BARS FILL FACE 1 ' - 0 " @ 10'-0"| CTS. 3" ~ WEEP HOLES 2 " 6"6" 6 " 6 " 6"6" 2 " 2 " 6 ' - 0 " 6'-0"6'-0" RIGHT ANGLE SECTION OF BARREL A400 BARS A200 BARS C L . 3 " C L . C O N S T . J T . * 5" HIGH C.H.C.U. B2 BARS A300 BARS A100 BARS B1 BARS (B.B.) @ 4'-0" CTS. B1 BARS C 1 B A R S @ 2 ' - 0 " C T S .2" CL. 2" CL. C L . C L . 2" CL. 2" CL. 4" TYP. 2" HIGH BEAM BOLSTERS * ALL CONTINUOUS HIGH CHAIR UPPER ( C.H.C.U. ) @ 3'-0" CTS. PERMITTED CONST. JT. CONST. JT. PERMITTED 4 " 10"10"10" 14'-6 1 ' - 0 "3-#8 S2 BARS 43'-5•" #5 B1 BARS STAGGERED EACH FACE GRADE -0.33% ELEV. 684.89 { -TRK5- 6'-2"6'-2" 13'-2Š" 1 ' - 0 " 1 ' - 6 " 1 ' - 6 " 1 ' - 0 " 1 ' - 0 " 1 ' - 0 " 8 ' - 0 " C1 BARS @ 3'-0" CTS. (TOP.) (BOT.) C1 BARS @ 1'-0" CTS. * 6‚" HIGH C.H.C.U. 1 ' - 0 " C T S . ( S . F . ) C 1 B A R S @ 2 ' - 6 " C T S . ( I . F . ) C 1 B A R S @ HOLES WEEP 3" ~ # 4 C 1 B A R S @ 1 ' - 0 " C T S . C1 BARS @ 1'-0" CTS. (TOP.) C1 BARS @ 3'-0" CTS. (BOT.) 6 " 10 " 90°-00'-00" 76°-34'-26" 9' -8ƒ " 2 '- 3 ‡ " 10'-0" 13°-25'-34" 12'-4†"5‚" 14'-10‡" @ 3" CTS 4-#5 G1 BARS 45'-0" LENGTH OF CULVERT = 70'-0" 3 ' - 9 " 3 ' - 9 " 3 ' - 5 " 3 ' - 5 " 7 ' - 2 " 7 ' - 2 " 25'-0" #6 A201 BARS ETC. @ 1'-0" CTS.#6 A200 BARS @ 1'-0" CTS. -TOP OF FLOOR SLAB 1'-0" #6 A100 BARS @ 1'-0" CTS.#6 A101 BARS ETC. @ 1'-0" CTS. 1'-0" #5 B2 BARS (TYP.) A1 BARS TOP OF FLOOR SLAB 3-#8 S2 BARS @ 5" CTS. 6 ' - 0 " UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL 2 ' - 0 " E A C H F A C E - S T A G G E R E D (3 B A R R U N ) B A R R E L S E C T I O N (3 B A R R U N ) E X T E R I O R W A L L S O F R O O F S L A B E A C H B A R R E L # 4 C 1 B A R S (3 B A R R U N ) T O P O F R O O F S L A B (3 B A R R U N ) @ 1 ' - 0 " C T S . - B O T T . (3 B A R R U N ) 1'-0" THERE ARE 62 "C" BARS IN SECTION OF BARREL. 6" BEVEL (TOP & BOT. SLAB) UPSTREAM END ONLY 5" BEVEL CTR. WALL 4‹" THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE S-12 14 BEVEL WALL @ 45° E. L KELLY,JR . APU19765 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG 140+14.92 -TRK5- VMW PEK 1-16 1-16 8 " 1 0 " 1 ' - 3 " 2 ' - 9 " 3 '-6 " 1 ' - 3 " 1 0 " 8 " 2 ' - 9 " 2'-2" 8" 1'-6" 8'-6" 5 '-2 ˆ" 11'-3" 6 '-10 ‰ " 1'-6" ELEVATION W2 ELEVATION W1 V4 V3JT. CONST. V2 V1 N4 N3 N2 N1 H2 H1 2-#4 H4 H3 (TYP.) 3-#6 S1* Z4 Z3 Z2 Z1 N4 N1 #5 T1 3-#4 N2 2-#4 N1 2-#4 N4 2-#4 N3 3" 3-#4 V2 2-#4 V1 2-#4 V4 2-#4 V3 3" 3-#4 Z2 2-#4 Z1 2-#4 Z4 2-#4 Z3 3" JT. CONST. V8V7V6V5 N8N7N6N5 H6 H5 H7 (TYP.) 2-#4 H8 3-#6 S1* Z5 Z6 Z7 Z8 N5 N8 3-#4 N5 3-#4 N6 3-#4 N7 3-#4 N8 3" 3-#4 V5 3-#4 V6 3-#4 V7 3-#4 V8 3" 3-#4 Z5 3-#4 Z6 3-#4 Z7 3-#4 Z8 3" PLAN W2 PLAN W1 6 - # 4 H 1 2 - # 4 H 2 10 - # 4 H 3 6 - # 4 H 5 2 - # 4 H 6 1 0 - # 4 H 7 #5 T2 BAR TYPES ALL BAR DIMENSIONS ARE OUT TO OUT. HK. 6" RAD. 2 '-0 " 1'-2†" 1 ' - 7 " 1'-3" 1 3 4 2'-0" 1'-7" 1 ' - 2 † " 1'-3" 2 9 •" Z8 2'-5"6" Z7 3'-0"6" Z6 3'-7"6" Z5 4'-1"6" Z4 2'-5"6" Z3 2'-11"6" Z2 3'-6"6" Z1 4'-3"6" 6 ' - 8 • " N 1 5 ' - 6 • " N 2 4 ' - 8 • " N 3 N 4 6 ' - 7 • " N 5 5 ' - 8 • " N 6 4 ' - 9 • " N 7 3 ' - 9 • " N 8 3 ' - 1 0 • " BILL OF MATERIAL BAR H1 NO. 12 SIZE #4 TYPE STR LENGTH 6'-7" WEIGHT 53 H2 4 #4 STR 3'-1"8 H3 20 #4 1 3'-3"43 H4 4 #4 STR 7'-1"19 H5 12 #4 STR 9'-4"75 H6 4 #4 STR 4'-10"13 H7 20 #4 2 3'-3"43 H8 4 #4 STR 9'-9"26 N1 4 #4 3 8'-2"22 N2 6 #4 3 7'-1"28 N3 4 #4 3 6'-2"16 N4 4 #4 3 5'-4"14 N5 6 #4 3 8'-1"32 N6 6 #4 3 7'-2"29 N7 6 #4 3 6'-3"25 N8 6 #4 3 5'-3"21 S1 12 #6 STR 6'-0"108 T1 6 #5 STR 8'-6"53 T2 6 #5 STR 11'-3"70 V1 4 #4 STR 6'-1"16 V2 6 #4 STR 4'-11"20 V3 4 #4 STR 4'-1"11 V4 4 #4 STR 3'-4"9 V5 6 #4 STR 6'-0"24 V6 6 #4 STR 5'-1"20 V7 6 #4 STR 4'-2"17 V8 6 #4 STR 3'-3"13 Z1 4 #4 4 4'-9"13 Z2 6 #4 4 4'-0"16 Z3 4 #4 4 3'-5"9 Z4 4 #4 4 2'-11"8 Z5 6 #4 4 4'-7"18 Z6 6 #4 4 4'-1"16 Z7 6 #4 4 3'-6"14 Z8 6 #4 4 2'-11"12 934 LBS FOR 4 WINGS REINFORCING STEEL TOTAL 2 END CURTAIN WALLS 2 HEADWALLS 4 WINGS CLASS A CONCRETE CY CY CY CY TOTAL 2 END CURTAIN WALLS 2 HEADWALLS 4 WINGS CLASS A CONCRETE 14.2 CY CY CY CY TOTAL 2 END CURTAIN WALLS 2 HEADWALLS 4 WINGS CLASS A CONCRETE CY CY CY CY 8" 4 " 1 ' - 0 " 8" 2 ' - 6 " JT. CONST. 10" 3 " C L . 2" CL. 3 " C L . 2" CL. SECTION TYPICAL WING 1 ' - 6 " 1 ' - 0 " 3 ' - 9 " 1 ' - 6 " 1 ' - 0 " 3 ' - 9 " 3 ' - 5 " 3 ' - 5 " TOP OF FOOTING "Z" BARS @ 1'-0" CTS. TOP OF FOOTING "Z" BARS @ 1'-0" CTS. # 4 "H " B A R S @ 1 ' - 6 " C T S . "V" BARS @ 1'-0" CTS "V" BARS @ 1'-0" CTS "N" BARS @ 1'-0" CTS "V" BARS "N" BARS "Z" BARS "N" BARS @ 1'-0" CTS 2'-10" MATERIAL À 1" EXP. JT.6'-8•" SLAB & FOOTING * S1 @ BOTTOM OF FLOOR 5‚" 2'-10" 8"4‹" 8'-11„" MATERIAL À 1" EXP. JT. MATERIAL À 1" EXP. JT. MATERIAL À 1" EXP. JT. (TYP.) "T" BARS FILL FACE FACE STREAM SHEET 3 OF 4 1.4 1.6 17.2 UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL STD. NO. CW7506 CONCRETE BOX CULVERT FOR STANDARD WINGS H = 6'-0"SLOPE = 2:1 75° OR 105° SKEW THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE S-13 14 E. L KELLY,JR. A PU19765 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 DRAWN BY : CHECKED BY : DATE : DATE : P-2918F MECKLENBURG 140+14.92 -TRK5- VMW PEK 1-16 1-16 Charlotte, NC 28202 NC License Number F-0991 900 West Trade St., Suite 715 STV ENGINEERS, INC. SHEET 4 OF 4 STANDARD NOTES STANDARD NOTES BRIDGES SHALL BE BUILT ON THE GRADE OR VERTICAL CURVE SHOWN ON PLANS. SLABS, CURBS AND PARAPETS SHALL CONFORM TO THE GRADE OR CURVE. ALL DIMENSIONS WHICH ARE GIVEN IN SECTION AND ARE AFFECTED BY DEAD LOAD ON PLANS. IN SETTING FORMS FOR STEEL BEAM BRIDGES AND PRESTRESSED CONCRETE GIRDER BRIDGES, ADJUSTMENTS SHALL BE MADE DUE TO THE DEAD LOAD DEFLECTIONS FOR THE ELEVATIONS SHOWN. WHERE BLOCKS ARE SHOWN OVER BEAMS FOR BUILDING UP TO THE SLAB, THE VERTICAL DIMENSIONS OF THE BLOCKS SHALL BE ADJUSTED ORDINATE, AND ACTUAL BEAM CAMBER. WHERE BOTTOM OF SLAB IS IN LINE WITH BOTTOM OF TOP FLANGES, DEPTH OF SLAB BETWEEN BEARINGS SHALL BE ADJUSTED TO COMPENSATE FOR DEAD LOAD DEFLECTION, VERTICAL CURVE ORDINATE, AND ACTUAL BEAM CAMBER. IN SETTING FALSEWORK AND FORMS FOR REINFORCED CONCRETE SPANS, AN AND PERMANENT CAMBER WHICH SHALL BE PROVIDED FOR IN ADDITION TO THE ELEVATIONS SHOWN. AFTER REMOVAL OF THE FALSEWORK, THE FINISHED STRUCTURES SHALL CONFORM TO THE PROFILE AND ELEVATIONS SHOWN ON THE PLANS AND CONSTRUCTION ELEVATIONS FURNISHED BY THE ENGINEER. INDICATED ON THE PLANS. WHEN BAR SUPPORT PIECES ARE PLACED IN CONTINUOUS LINES, THEY SHALL BE SO PLACED THAT THE ENDS OF THE SUPPORTING WIRES SHALL BE LAPPED TO LOCK LEGS ON ADJOINING PIECES. STRUCTURAL STEEL: SUBSTITUTE FOR THE COVER PLATES DESIGNATED ON THE PLANS COVER PLATES OF THE EQUIVALENT AREA PROVIDED THESE PLATES ARE AT LEAST 5/16" IN THICKNESS AND DO NOT EXCEED A WIDTH EQUAL TO THE FLANGE WIDTH LESS 2" OR A THICKNESS EQUAL TO 2 TIMES THE FLANGE THICKNESS. THE SIZE OF FILLET WELDS SHALL CONFORM ELECTROSLAG WELDING WILL NOT BE PERMITTED. ROUNDED BY SUITABLE MEANS TO A RADIUS OF APPROXIMATELY 1/16 INCH OR ETC. IN CASTING SUPERSTRUCTURES: ALLOWANCE FOR DEAD LOAD DEFLECTION, SETTLEMENT, DEFLECTIONS ARE DIMENSIONS AT CENTER LINE OF BEARING UNLESS OTHERWISE NOTED REINFORCING STEEL: WIRE BAR SUPPORTS SHALL BE PROVIDED FOR REINFORCING STEEL WHERE EXCEPT AT THE INTERIOR SUPPORTS OF CONTINUOUS BEAMS WHERE THE COVER WITH THE SOLE EXCEPTION OF EDGES AT SURFACES WHICH BEAR ON OTHER AT THE CONTRACTOR'S OPTION, HE MAY SUBSTITUTE 7/8" ~ SHEAR STUDS FOR THE STUDS FOR 4 - 3/4" ~ STUDS. STUDS OF THE LENGTH SPECIFIED ON THE PLANS MUST ALONG THE BEAM AS SHOWN FOR 3/4" ~ STUDS BASED ON THE RATIO OF 3 - 7/8" ~ BE PROVIDED. THE MAXIMUM SPACING SHALL BE 2'-O". THE RATE OF 3 - 7/8" ~ STUDS FOR 4 - 3/4" ~ STUDS, AND STUD SPACING CHANGES SHALL BE MADE AS NECESSARY TO PROVIDE THE SAME EQUIVALENT NUMBER OF 7/8" ~ STUDS PLATE IS IN CONTACT WITH BEARING PLATE, THE CONTRACTOR MAY, AT HIS OPTION, OR METALLIZING. EQUIVALENT FLAT SURFACE AT A SUITABLE ANGLE PRIOR TO PAINTING, GALVANIZING, STRESS IN EXTREME FIBER OF IMPACT ALLOWANCE LIVE LOAD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 27,000 LBS. PER SQ. IN. 20,000 LBS. PER SQ. IN. DESIGN DATA: SPECIFICATIONS - - - - - - - - - - - - - - - DOWELS WHEN INDICATED ON PLANS AS FOR CULVERT EXTENSIONS, SHALL DOWELS: MATERIAL AND WORKMANSHIP: UNLESS OTHERWISE REQUIRED ON PLANS, CLASS A CONCRETE SHALL BE CONCRETE: 1,800 LBS. PER SQ. IN. EQUIVALENT FLUID PRESSURE OF EARTH - - - - - (MINIMUM) 30 LBS. PER CU. FT. 375 LBS. PER SQ. IN.- - - -OF TIMBER COMPRESSION PERPENDICULAR TO GRAIN PROVISIONS, ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH TOP CORNERS OF CURBS MAY BE ROUNDED TO 1-1/2" RADIUS WHICH IS BUILT INTO CURB FORMS; CORNERS OF TRANSVERSE FLOOR EXPANSION JOINTS SHALL BE ROUNDED WITH A 1/4" FINISHING TOOL UNLESS OTHERWISE REQUIRED ON PLANS; AND CORNERS OF EXPANSION JOINTS IN THE ROADWAY FACES CONCRETE IN COMPRESSION CONCRETE IN SHEAR - - - - - - - - - - - - - - - - - - - - - - - 1,200 LBS. PER SQ. IN. SEE A.A.S.H.T.O. EXCEPT AS MAY OTHERWISE BE SPECIFIED ON PLANS OR IN THE SPECIAL N. C. DEPARTMENT OF TRANSPORTATION. USED FOR ALL PORTIONS OF ALL STRUCTURES WITH THE EXCEPTION THAT: CLASS AA CONCRETE SHALL BE USED IN BRIDGE SUPERSTRUCTURES, CONCRETE CHAMFERS: UNLESS OTHERWISE NOTED ON THE PLANS, ALL EXPOSED CORNERS ON STRUCTURES SHALL BE CHAMFERED 3/4" WITH THE FOLLOWING EXCEPTIONS: AND TOPS OF CURBS AND SIDEWALKS SHALL BE ROUNDED TO A 1/4" RADIUS WITH A FINISHING STONE OR TOOL UNLESS OTHERWISE REQUIRED ON PLANS. BE EMBEDDED AT LEAST 12" INTO THE OLD CONCRETE AND GROUTED INTO GRADE 60 24,000 LBS. PER SQ. IN. 27,000 LBS. PER SQ. IN. - - SURFACES,ALL SHARP EDGES AND ENDS OF SHAPES AND PLATES SHALL BE SLIGHTLY PLACE WITH 1:2 CEMENT MORTAR. - - - - - ALLOWANCE SHALL BE MADE FOR DEAD LOAD DEFLECTIONS, SETTLEMENT OF FALSEWORK, TO THE REQUIREMENTS OF THE CURRENT ANSI/AASHTO/AWS " BRIDGE WELDING CODE". BETWEEN BEARINGS TO COMPENSATE FOR DEAD LOAD DEFLECTIONS, VERTICAL CURVE ƒ" ~ STUDS SPECIFIED ON THE PLANS. THIS SUBSTITUTION SHALL BE MADE AT STRUCTURAL STEEL - AASHTO M270 GRADE 36 - - AASHTO M270 GRADE 50W - - AASHTO M270 GRADE 50 - THE 2012 ``STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES" OF THE ABUTMENT BACKWALLS, AND APPROACH SLABS; AND CLASS B CONCRETE SHALL BE USED FOR SLOPE PROTECTION AND RIP RAP. ALL REINFORCING STEEL SHALL BE DEFORMED. DIMENSIONS RELATIVE TO PLACEMENT OF REINFORCING ARE TO CENTERS OF BARS UNLESS OTHERWISE INDICATED IN THE PLANS. DIMENSIONS ON BAR DETAILS ARE TO CENTERS OF BARS OR ARE OUT TO OUT AS INDICATED ON PLANS. SEE A.A.S.H.T.O. SEE PLANS A.A.S.H.T.O. (CURRENT) UNTREATED - EXTREME FIBER STRESS STRUCTURAL TIMBER - TREATED OR BE HOT ROLLED. STEEL SHEET PILING FOR PERMANENT OR TEMPORARY APPLICATIONS SHALL FALSEWORK OR FORMS IS STARTED. BE SUBMITTED TO THE ENGINEER FOR APPROVAL BEFORE CONSTRUCTION OF THE AND ANY STRUCTURE OR PARTS OF A STRUCTURE AS NOTED ON THE PLANS SHALL DETAILED DRAWINGS FOR FALSEWORK OR FORMS FOR BRIDGE SUPERSTRUCTURE REINFORCING STEEL IN TENSION, METAL HANDRAILS SHALL BE IN ACCORDANCE WITH THE PLANS. RAILS SHALL BE RAIL SHALL BE SET NORMAL TO THE GRADE OF THE CURB, UNLESS OTHERWISE SHOWN METAL STANDARDS AND FACES OF THE CONCRETE END POSTS FOR THE METAL HANDRAILS AND POSTS: SPECIFICATIONS ARTICLE 105-4. OVER NOTES HEREON, AND SPECIAL PROVISIONS SHALL GOVERN OVER ALL. SEE GOVERN OVER THE SPECIFICATIONS, BUT THE REMAINDER OF THE PLANS SHALL GOVERN GENERALLY, IN CASE OF DISCREPANCY, THIS STANDARD SHEET OF NOTES SHALL SPECIAL NOTES: AS MANUFACTURED FOR BRIDGE RAILING. CASTINGS SHALL BE OF A UNIFORM APPEARANCE. FINS AND OTHER DEFORMATIONS RESULTING FROM CASTING OR OTHERWISE SHALL BE REMOVED IN A MANNER SO THAT A UNIFORM COLORING OF THE COMPLETED CASTING SHALL NOT BE ACCEPTED. CERTIFIED MILL REPORTS ARE REQUIRED FOR METAL RAILS AND POSTS. ON PLANS. THE METAL RAIL AND TOPS OF CONCRETE POSTS USED WITH THE ALUMINUM RAIL SHALL BE BUILT PARALLEL TO THE GRADE OF THE CURB. BE OBTAINED. CASTINGS WITH DISCOLORATIONS OR OF NON-UNIFORM COLORING WILL THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE SN 14 DocuSign Envelope ID: 4FE09C9A-6107-40F0-8CF1-F95C96825838DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 2 4 1 , ' % 6  4 ' ( ' 4 ' 0 % '  0 1  5 * ' ' 6  0 1  4  9  5 * ' ' 6  0 1  ' . ' % 6 4 + % # . ' 0 ) + 0 ' ' 4 S T V E n g i n e e r s , I n c . #    4    %    *    +    6    '    %    6    5 1 4 0 1 W E S T M O R E H E A D S T R E E T , S U I T E 1 2 5 C H A R L O T T E N C 2 8 2 0 8 ( 7 0 4 ) 5 5 2 - 5 8 0 0 F A X ( 7 0 4 ) 5 5 2 - 7 4 2 0 2 Ä     ( '     A L L P R O D U C T S , B U I L D I N G M A T E R I A L S , A N D E Q U I P M E N T O N T H I S P R O J E C T S H A L L D   d  ͞  h z   D  Z /   ͟  Z  Y h / Z  D  E d ^ ͘      ,  ^ , K W   Z  t / E '  ^ h  D / d d  >  ^ ,  > >    A C C O M P A N I E D W I T H A L E T T E R O F C E R T I F I C A T I O N F R O M T H E M A N U F A C T U R E R R E G A R D L E S S O F W H E T H E R O R N O T T H E I T E M W A S S P E C I F I E D . DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 2 4 1 , ' % 6  4 ' ( ' 4 ' 0 % '  0 1  5 * ' ' 6  0 1  4  9  5 * ' ' 6  0 1  ' . ' % 6 4 + % # . ' 0 ) + 0 ' ' 4 S T V E n g i n e e r s , I n c . #    4    %    *    +    6    '    %    6    5 1 4 0 1 W E S T M O R E H E A D S T R E E T , S U I T E 1 2 5 C H A R L O T T E N C 2 8 2 0 8 ( 7 0 4 ) 5 5 2 - 5 8 0 0 F A X ( 7 0 4 ) 5 5 2 - 7 4 2 0 2 Ä     ( '     1 8 ' 4 # . .  2 . # 0 A L L P R O D U C T S , B U I L D I N G M A T E R I A L S , A N D E Q U I P M E N T O N T H I S P R O J E C T S H A L L D   d  ͞  h z   D  Z /   ͟  Z  Y h / Z  D  E d ^ ͘      ,  ^ , K W   Z  t / E '  ^ h  D / d d  >  ^ ,  > >    A C C O M P A N I E D W I T H A L E T T E R O F C E R T I F I C A T I O N F R O M T H E M A N U F A C T U R E R R E G A R D L E S S O F W H E T H E R O R N O T T H E I T E M W A S S P E C I F I E D . DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 2 4 1 , ' % 6  4 ' ( ' 4 ' 0 % '  0 1  5 * ' ' 6  0 1  4  9  5 * ' ' 6  0 1  ' . ' % 6 4 + % # . ' 0 ) + 0 ' ' 4 S T V E n g i n e e r s , I n c . #    4    %    *    +    6    '    %    6    5 1 4 0 1 W E S T M O R E H E A D S T R E E T , S U I T E 1 2 5 C H A R L O T T E N C 2 8 2 0 8 ( 7 0 4 ) 5 5 2 - 5 8 0 0 F A X ( 7 0 4 ) 5 5 2 - 7 4 2 0 2 Ä     ( '     '0.# 4 ) ' &  2 . # 6 ( 1 4 /  2 . # 0  Ä  . + ) * 6 5  # 0 &  2 1 9 ' 4 A L L P R O D U C T S , B U I L D I N G M A T E R I A L S , A N D E Q U I P M E N T O N T H I S P R O J E C T S H A L L D   d  ͞  h z   D  Z /   ͟  Z  Y h / Z  D  E d ^ ͘      ,  ^ , K W   Z  t / E '  ^ h  D / d d  >  ^ ,  > >    A C C O M P A N I E D W I T H A L E T T E R O F C E R T I F I C A T I O N F R O M T H E M A N U F A C T U R E R R E G A R D L E S S O F W H E T H E R O R N O T T H E I T E M W A S S P E C I F I E D . '0.# 4 ) ' &  2 . # 6 ( 1 4 /  2 . # 0  Ä  # / 6 4 # -  ; # 4 &  2 1 9 ' 4  % 1 0 6 4 1 .  7 0 + 6 5 2.#6(14/5'%6+102.#6 ( 1 4 /  ' 3 7 + 2 / ' 0 6  & + / ' 0 5 + 1 0 + 0 )  2 . # 0 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 2 4 1 , ' % 6  4 ' ( ' 4 ' 0 % '  0 1  5 * ' ' 6  0 1  4  9  5 * ' ' 6  0 1  ' . ' % 6 4 + % # . ' 0 ) + 0 ' ' 4 S T V E n g i n e e r s , I n c . #    4    %    *    +    6    '    %    6    5 1 4 0 1 W E S T M O R E H E A D S T R E E T , S U I T E 1 2 5 C H A R L O T T E N C 2 8 2 0 8 ( 7 0 4 ) 5 5 2 - 5 8 0 0 F A X ( 7 0 4 ) 5 5 2 - 7 4 2 0 2 Ä     ( '     ' 0 . # 4 ) ' &  % . ' # 0 + 0 )  5 6 1 4 # ) '  $ 7 + . & + 0 )  2 . # 0 5 ' 0 . # 4 ) ' &  ' . ' % 6 4 + % # .    % 1 / 2 4 ' 5 5 1 4  $ 7 + . & + 0 )  2 . # 0 5 A L L P R O D U C T S , B U I L D I N G M A T E R I A L S , A N D E Q U I P M E N T O N T H I S P R O J E C T S H A L L D   d  ͞  h z   D  Z /   ͟  Z  Y h / Z  D  E d ^ ͘      ,  ^ , K W   Z  t / E '  ^ h  D / d d  >  ^ ,  > >    A C C O M P A N I E D W I T H A L E T T E R O F C E R T I F I C A T I O N F R O M T H E M A N U F A C T U R E R R E G A R D L E S S O F W H E T H E R O R N O T T H E I T E M W A S S P E C I F I E D . 2 1 9 ' 4  2 . # 0 2 1 9 ' 4  2 . # 0 . + ) * 6 + 0 )  2 . # 0 . + ) * 6 + 0 )  2 . # 0 219'44+5'4&+#) 4 # / DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 6;2+%# .  . 7 / + 0 # + 4 '  / 1 7 0 6 + 0 )  # 4 / 5 & 1 7 $ . '  # 4 /  6 ' 0 1 0  / 1 7 0 6 + 0 ) / # 5 6  # 4 /  / 1 7 0 6  5 * 1 9 0 4 1 7 0 &  % 1 0 % 4 ' 6 '  2 1 . '  Ä  & + 4 ' % 6  5 ' 6  6 ' 0 1 0  / 1 7 0 6 & + 4 ' % 6  5 ' 6  6 ' 0 1 0  / 1 7 0 6 4 1 7 0 &  % 1 0 % 4 ' 6 '  2 1 . '  Ä ) 4 1 7 0 & + 0 )  ( 1 4 2 4 1 , ' % 6  4 ' ( ' 4 ' 0 % '  0 1  5 * ' ' 6  0 1  4  9  5 * ' ' 6  0 1  ' . ' % 6 4 + % # . ' 0 ) + 0 ' ' 4 S T V E n g i n e e r s , I n c . #    4    %    *    +    6    '    %    6    5 1 4 0 1 W E S T M O R E H E A D S T R E E T , S U I T E 1 2 5 C H A R L O T T E N C 2 8 2 0 8 ( 7 0 4 ) 5 5 2 - 5 8 0 0 F A X ( 7 0 4 ) 5 5 2 - 7 4 2 0 2 Ä     ( '     A L L P R O D U C T S , B U I L D I N G M A T E R I A L S , A N D E Q U I P M E N T O N T H I S P R O J E C T S H A L L D   d  ͞  h z   D  Z /   ͟  Z  Y h / Z  D  E d ^ ͘      ,  ^ , K W   Z  t / E '  ^ h  D / d d  >  ^ ,  > >    A C C O M P A N I E D W I T H A L E T T E R O F C E R T I F I C A T I O N F R O M T H E M A N U F A C T U R E R R E G A R D L E S S O F W H E T H E R O R N O T T H E I T E M W A S S P E C I F I E D . DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 2 4 1 , ' % 6  4 ' ( ' 4 ' 0 % '  0 1  5 * ' ' 6  0 1  4  9  5 * ' ' 6  0 1  ' . ' % 6 4 + % # . ' 0 ) + 0 ' ' 4 S T V E n g i n e e r s , I n c . #    4    %    *    +    6    '    %    6    5 1 4 0 1 W E S T M O R E H E A D S T R E E T , S U I T E 1 2 5 C H A R L O T T E N C 2 8 2 0 8 ( 7 0 4 ) 5 5 2 - 5 8 0 0 F A X ( 7 0 4 ) 5 5 2 - 7 4 2 0 2 Ä     ( '     A L L P R O D U C T S , B U I L D I N G M A T E R I A L S , A N D E Q U I P M E N T O N T H I S P R O J E C T S H A L L D   d  ͞  h z   D  Z /   ͟  Z  Y h / Z  D  E d ^ ͘      ,  ^ , K W   Z  t / E '  ^ h  D / d d  >  ^ ,  > >    A C C O M P A N I E D W I T H A L E T T E R O F C E R T I F I C A T I O N F R O M T H E M A N U F A C T U R E R R E G A R D L E S S O F W H E T H E R O R N O T T H E I T E M W A S S P E C I F I E D . #/64#-;#4&219'4%1064 1 .  7 0 + 6 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 2 4 1 , ' % 6  4 ' ( ' 4 ' 0 % '  0 1  5 * ' ' 6  0 1  4  9  5 * ' ' 6  0 1  ' . ' % 6 4 + % # . ' 0 ) + 0 ' ' 4 S T V E n g i n e e r s , I n c . #    4    %    *    +    6    '    %    6    5 1 4 0 1 W E S T M O R E H E A D S T R E E T , S U I T E 1 2 5 C H A R L O T T E N C 2 8 2 0 8 ( 7 0 4 ) 5 5 2 - 5 8 0 0 F A X ( 7 0 4 ) 5 5 2 - 7 4 2 0 2 Ä     ( '     A L L P R O D U C T S , B U I L D I N G M A T E R I A L S , A N D E Q U I P M E N T O N T H I S P R O J E C T S H A L L D   d  ͞  h z   D  Z /   ͟  Z  Y h / Z  D  E d ^ ͘      ,  ^ , K W   Z  t / E '  ^ h  D / d d  >  ^ ,  > >    A C C O M P A N I E D W I T H A L E T T E R O F C E R T I F I C A T I O N F R O M T H E M A N U F A C T U R E R R E G A R D L E S S O F W H E T H E R O R N O T T H E I T E M W A S S P E C I F I E D . DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B80010T_P08 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ H Y D _ 1 A . d g n n o r i e g s c PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 5 4 " W A T E R L I N E S S G V W V G V S G M GV G V D WM GVWM S W V W M W V WVD WM GV WM WM WV S WV WM WM WV WM WM 10' ALLEY W E S T P A L M E R S T R E E T C L O S E D 0 8 / 2 8 / 1 9 8 9 R E S . B K . 2 5 , P G . 3 4 8 D E E D B K . 6 1 6 1 , P G . 8 1 2 10' ALLEY -TRK7- -TRK6- 1 2 5 -TRK5- CURVE TRK7 - 1 CURV E TRK 6 - 1 CURVE TRK 5 - 2 CURVE TRK5-1 1 2 0 10 715.28 24.7-FT 18" RCP PROPOSED DITCH RT. DITCH LT. PROPOSED 700.60 700.60 699.68 37.0-FT 18" RCP 700.83 05 20 30 CONCRETE ENDWALLS WITH NCDOT STD. 838.01 PROPOSED (2) 18" RCP 701.84 25 703.00 7 02 7 0 3 7 0 4 70 2 70 3 7 04 7 0 5 PROPOSED 18" RCP 700.71 700.33 700.33 7 06 707 7 0 7 40.5-FT 18" RCP 40.5-FT 18" RCP 702.31 697.90697.90 695.66 699.53 697.56 695.33 4-FT DIAMETER PRECAST MANHOLE STD. 840.52 PROPOSED NCDOT NO. 1 UNDERDRAIN PROPOSED TYPICAL PROPOSED CLEAN OUT NO. 2 UNDERDRAIN PROPOSED RCP PROPOSED 18" 4-FT DIAMETER PRECAST MANHOLE STD. 840.52 PROPOSED NCDOT POND NO. 2 WATER QUALITY FOREBAY FOR PROPOSED SEDIMENT 35 40 PROPOSED DITCH RT. STD. 838.80 HEADWALL PROPOSED NCDOT CATCH BASIN STD. 840.02 PROPOSED NCDOT CATCH BASIN STD. 840.02 PROPOSED NCDOT 2 4 5052 810 12 54 696.89 694.64 T O GA S T ON IA P A L M E R S T R E E T 3 5 ' P U B L I C R / W J O H N B E L K F R E E W A Y W ES T IN T E R S T A T E 277 GRAHAM STREET 40' PUBLIC R/W STAGE 1 S T A K E S L O P E VAR. Type of Liner= PSRM ( Not to Scale) D I T C H B E G I N VAR. S L SR SEC. SEE TYP D+0.50' BPSRM S T A K E S L O P E VAR. ( Not to Scale) D I T C H B E G I N VAR. S L SR SEC. SEE TYP D+0.50' BPSRM S T AK E S L O P E VAR. ( Not to Scale) D I T C H B E G I N VAR. S L SR SEC. SEE TYP D+0.50' BPSRM S T A K E S L O P E VAR. ( Not to Scale) D I T C H B E G I N VAR. S L SR SEC. SEE TYP D+0.50' BPSRM S T AK E S L O P E VAR. ( Not to Scale) D I T C H B E G I N VAR. S L SR SEC. SEE TYP D+0.50' BPSRM PERMANENT DIVERSION PERMANENT DIVERSION PERMANENT DIVERSION MAINLINE DITCH DETAIL A MIN DEPTH (D): VARIES BTM WIDTH (B): 25.0' SLOPE RIGHT (SR): 2:1 SLOPE LEFT (SL): 2:1 MIN DEPTH (D): VARIES BTM WIDTH (B): 2.0' SLOPE RIGHT (SR): 2:1 SLOPE LEFT (SL): 2:1 MIN DEPTH (D): VARIES BTM WIDTH (B): 4.0' SLOPE RIGHT (SR): 2:1 SLOPE LEFT (SL): 2:1 Type of Liner= PSRM Type of Liner= PSRM Type of Liner= PSRM Type of Liner= PSRM N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL S T A K E S L O P E VAR. Type of Liner= PSRM ( Not to Scale) D I T C H B E G I N VAR. S L SR SEC. SEE TYP D+0.50' BPSRM PERMANENT DIVERSION MIN DEPTH (D): VARIES BTM WIDTH (B): 8.0' SLOPE RIGHT (SR): 2:1 SLOPE LEFT (SL): 2:1 DETAIL B DETAIL C DETAIL D DETAIL E INTERIM DITCH DETAIL F MIN DEPTH (D): VARIES BTM WIDTH (B): 6.0' SLOPE RIGHT (SR): 2:1 SLOPE LEFT (SL): 2:1 LT. PSRM UP TO CUT LIMITS RT. PSRM UP TO SHOULDER BREAK FROM STA. 122+00 TO STA. 125+50 LT LT. PSRM UP TO CUT LIMITS RT. PSRM UP TO SHOULDER BREAK FROM STA. 126+00 TO STA. 133+50 LT FROM STA. 120+00 TO STA. 122+00 RT MIN DEPTH (D): VARIES BTM WIDTH (B): 2.0' SLOPE RIGHT (SR): 2:1 SLOPE LEFT (SL): 2:1 LT. PSRM UP TO CUT LIMITS RT. PSRM UP TO SHOULDER BREAK FROM STA. 134+00 TO STA. 140+75 LT RT. PSRM UP TO CUT LIMITS LT. PSRM UP TO SHOULDER BREAK FROM STA. 121+50 TO STA. 129+00 RT. RT. TSRM UP TO CUT LIMITS LT. TSRM UP TO CUT LIMITS FROM STA. 136+28 LT. TO SUMMIT AVE. UNDERDRAIN NO. 1 NO. CLEAN OUT STATION ELEVATION 2 122+00 703.00 122+50 702.36 123+00 701.73 123+50 701.10 124+00 700.38 124+50 699.76 125+00 699.13 125+50 698.51 126+00 697.90 126+00 697.90 126+50 697.26 127+00 696.64 127+50 696.06 128+00 695.64 128+00 695.26 128+50 695.01 UNDERDRAIN NO. 1 NO. CLEAN OUT STATION ELEVATION 16 129+00 694.76 129+50 694.51 130+00 694.26 130+50 694.76 131+00 695.26 131+00 695.26 131+50 694.76 132+00 694.26 132+50 694.76 133+00 695.26 133+00 695.26 133+50 694.76 134+00 694.26 134+50 694.76 135+00 695.26 135+00 695.26 UNDERDRAIN NO. 1 NO. CLEAN OUT STATION ELEVATION 34 135+50 694.76 136+00 694.26 136+50 694.76 137+00 695.26 137+00 695.26 137+50 694.76 138+00 694.26 138+50 694.76 139+00 695.26 139+00 695.26 139+50 694.76 139+64 694.63 140+00 694.90 140+50 695.26 UNDERDRAIN NO. 2 NO. CLEAN OUT STATION ELEVATION 50 124+50 699.53 125+00 698.84 125+50 698.19 126+00 697.56 126+50 696.95 127+00 696.37 127+50 695.80 128+00 695.33 128+50 695.03 129+00 694.16 129+50 694.41 130+00 694.66 130+50 694.90 UNDERDRAIN NO. 2 NO. CLEAN OUT STATION ELEVATION 52 132+50 693.65 133+00 694.15 133+50 694.65 134+00 695.15 134+00 695.15 134+50 694.65 135+00 694.15 135+50 694.65 136+00 695.15 136+00 695.15 136+50 694.65 137+00 694.15 4 8 10 12 14 18 20 22 24 26 28 30 32 36 38 40 42 44 46 48 131+00 695.15 131+00 695.15 131+50 694.65 132+00 694.15 137+50 693.65 138+00 693.15 138+50 692.65 139+00 692.14 UNDERDRAIN NO. 2 139+50 691.64 139+64 691.50 54 56 58 60 62 64 66 68 70 72 74 76 2 4 " M I N . VA R I E S 18" TYP. BOX COVER TYP. PRECAST CONCRETE VALVE TYPICAL CAST IRON CLEAN OUT WOVEN FILTER FABRIC WRAPPED WITH NON NO. 57 CRUSHED STONE BALLAST SUBBALLAST ASPHALT ABC GEOTEXTILE WALL HDPE WITH 6" PERFORATED SMOOTH 2. 1. 3. 4. 5. 6. (SCS) CODE 606. ASTM F405, ASTM F667, AASHTO M252, AASHTO M294 AND NRCS REQUIREMENTS SPECIFIED IN THE FOLLOWING INDUSTRY STANDARDS: PIPE SHALL BE MANUFACTURED TO COMPLY WITH THE PERFORATION PIPE SHALL HAVE 6 PERFORATIONS SPACED AT 60deg - MIN. STRUCTURES SHALL BE WATER TIGHT. ALL PIPE CONNECTIONS SHALL BE WATER TIGHT. CONNECTIONS TO PERFORATED 6" SMOOTH WALL HDPE. ALL HEADER PIPES CONNECTING TO STRUCTURES SHALL BE NON BALLAST. INSTALL VALVE COVER AND CLEAN OUT LEVEL WITH THE TOP OF AN ACCEPTABLE SUBSTITUTE. CLAY AND ORGANIC MATTER). CALCIUM CARBONATE AGGREGATE IS NOT ALL CRUSHED STONE MATERIAL SHALL HAVE LESS THAN 1% SILT, UNDERDRAIN NOTES INVERT ELEV. HYD-1A UNDERDRAIN NO. 1 QUANTITY SUMMARY: 6" PERFORATED SMOOTH WALL HDPE: 1900-LF 6" NON-PERF. SMOOTH WALL HDPE: 128-LF 6" CAST IRON CLEAN OUTS: 23 UNDERDRAIN NO. 2 QUANTITY SUMMARY: 6" PERFORATED SMOOTH WALL HDPE: 1520-LF 6" NON-PERF. SMOOTH WALL HDPE: 80-LF 6" CAST IRON CLEAN OUTS: 14 M A T C H L I N E P R O P . T R A C K # 5 S T A . 12 8 +00 S EE S H EE T HY D -2 A DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ H Y D _ 1 B . d g n n o r i e g s c PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 4" PVC S/LCO 700.94 5 4 " W A T E R L I N E S S G V W V G V S G M GV G V D WM GVWM S W V W M W V WVD WM GV WM WM WV S WV WM WM WV WM WM 10' ALLEY W E S T P A L M E R S T R E E T C L O S E D 0 8 / 2 8 / 1 9 8 9 R E S . B K . 2 5 , P G . 3 4 8 D E E D B K . 6 1 6 1 , P G . 8 1 2 10' ALLEY -TRK7- -TRK6- 1 2 5 -TRK5- CURVE TRK7 - 1 CURV E TRK 6 - 1 CURVE TRK 5 - 2 24.7-FT 18" RCP 715.28 700.60 700.6040.5-FT 18" RCP 40.5-FT 18" RCP 700.33 700.33 699.68 700.83 700.71 701.84 696.89 694.64 201.6-LF 18" RCP P A L M E R S T R E E T 3 5 ' P U B L I C R / W S T R EE T W E S T M O R E H E A D J O H N B E L K F R E E W A Y W ES T IN T E R S T A T E 277 GRAHAM STREET 40' PUBLIC R/W PLANS) (SEE STAFF BUILDING/ARCHITECTUAL RETAINING WALL BY OTHERS PROP. FACILITY, PARKING, AND STAGE 2 N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL HYD-1B M A T C H L I N E P R O P . T R A C K # 5 S T A . 12 8 +00 S EE S H EE T HY D -2 B DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ H Y D _ 2 A . d g n n o r i e g s c PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. D I CB C B CB C B C B C B C B GA S L I N E L O C A T IO N P E R F I E L D M A R K ING S RAILROAD SPURLINE RAILROAD SPURLINE R AIL R O A D SP U R LI N E RAILROAD MAINLINE TRACK 1 RAILROAD MAINLINE TRACK 2 2 0 ' M B S L ( T Y P I C A L ) S S B U I L D I N G ( T Y P I C A L ) D I C B CB C B C B C B D I D I C B D I D I D I D I S S W V G V W M W M S S W M W V W V W MW V W V W V W M S S W M D S W V W V S GV W M W V D S S WV D GV S D D D W V W M W V S W M S W M W M S WV WV S D GVWV D WV WV W V S WV WV WM WVWV WV WM D -TRK6- -TRK5- 1 3 0 1 3 5 -TRK7- 689.13 687.73 682.25 INTERIM PHASE DITCH @ 0.90% PROPOSED 18" RCP PROPOSED 18" RCP PROPOSED DITCH RT. 691.39 97.6-FT 18" RCP 692.03 692.03 245.0-FT 18" RCP 692.78 345.5-FT 18" RCP 693.83 696.27 696.16 No. 2 UNDERDRAIN PROPOSED 840.36 DROP INLET PROPOSED NCDOT STD. 692.78 45 50 41.0-FT 18" RCP 703704705706707 STD. 838.80 HEADWALL PROPOSED NCDOT 683.09 INTERIM PHASE DITCH @ 1.1% 695.66695.26 694.26 695.26695.26 694.26 695.26695.26 694.26 695.26695.26 694.26 695.33 694.16 695.15695.15 693.65 695.15695.15 694.15 695.15 DROP INLET STD. 840.36 PROPOSED NCDOT NO. 2 TYPICAL DRAIN TO POND GRADE AREA TO 55 6065 105 110 100DROP INLET STD. 840.36 PROPOSED NCDOT NO. 2 QUALITY POND PROPOSED WATER DROP INLET STD. 840.36 PROPOSED NCDOT TYPICAL CLEANOUT PROPOSED NO. 1 UNDERDRAIN PROPOSED CATCH BASIN STD. 840.02 PROPOSED NCDOT CATCH BASIN STD. 840.02 PROPOSED NCDOT 70 PROPOSED 18" RCP FOR STAGE 1 TO BE TRUNCATED PROPOSED 18" RCP TRUNCATED FOR STAGE 1 ATTENUATOR LT. PROPOSED STORMWATERFOR STAGE 1 TO BE TRUNCATED PROPOSED 18" RCP (APPROX. LOCATION) INTERIM DITCH STAGE 1 STRUCTURE WALL) (REMOVE PORTION OF EAST FROM DITCH TO ENTER WALL TO ALLOW DISCHARGE ADJUST EXISTING STRUCTURE CATCH BASIN STD. 840.02 PROPOSED NCDOT NO. 1 UNDERDRAIN PROPOSED PROPOSED 18" RCP CATCH BASIN STD. 840.02 PROPOSED NCDOT 16 24 30 28 34 56 68 14 2226 32 60 62 58 646670 20 18 694.64 197-LF 18" RCP 694.04694.04 197-LF 18" RCP 693.44693.44 692.84692.84 692.24692.24 7 1 4 7 1 4 7 1 5 7 1 5 7 1 6 7 1 6 7 1 6 7 1 6 7 1 7 717 7 1 7 7 1 7 717 7 1 7 7 1 8 7 1 8 718 7 1 8 7 1 8 718 7 1 9 71 9 7 1 9 7 1 9 71 9 7 1 9 7 2 0 720 7 2 0 7 2 0 720 7 2 0 7 2 1 7 21 7 2 1 7 2 1 7 21 7 2 1 72 2 722 72 2 722 723 723 723 723724 7 2 4 724 7 2 4 72 5 725 72 5 725 7 2 6 7 2 6 727727 728728 729729 6 0 ' P U B L I C R / W P E N M A N S T R E E T 5 0' P U B LI C R/ W W E S T S U M M I T A V E . W I N O N A S T R E E T 5 0' P U B L I C R / W GRAHAM STREET 50' PUBLIC R/W STAGE 1 N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL HYD-2A M A T C H L I N E P R O P . T R A C K # 5 S T A . 1 2 8 + 0 0 S E E S H E E T H Y D - 1 A DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ H Y D _ 2 B . d g n n o r i e g s c PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. D I CB C B CB C B C B C B C B GA S L I N E L O C A T IO N P E R F I E L D M A R K ING S RAILROAD SPURLINE RAILROAD SPURLINE R AIL R O A D SP U R LI N E RAILROAD MAINLINE TRACK 1 RAILROAD MAINLINE TRACK 2 2 0 ' M B S L ( T Y P I C A L ) S S B U I L D I N G ( T Y P I C A L ) D I C B CB C B C B C B D I D I C B D I D I D I D I S S W V G V W M W M S S W M W V W V W MW V W V W V W M S S W M D S W V W V S GV W M W V D S S WV D GV S D D D W V W M W V S W M S W M W M S WV WV S D GVWV D WV WV W V S WV WV WM WVWV WV WM D C C C C C TRK6-2 CURVE -TRK5- 1 4 0 -TRK7- -TRK6- 1 3 0 -TRK5- 1 3 5 838.80 ENDWALL PROPOSED NCDOT STD.(SPECIAL DESIGN) WITH HEADWALLS 6X6 BOX CULVERT PROPOSED DOUBLE 685 686687 688689690691692 684 684.00 80 85 90 95 684.81 684.81 57.6-FT 6x6 RCBC 57.6-FT 6x6 RCBC 685.04 685.04 684.35 684.00 684.00 33.1-FT 18" RCP 683.54 688.45 52-FT 36" RCP 690.45 691.07 690 686 687 688 6 8 3 6 8 4 6 8 5 6 8 6 6 8 7 6 8 8 6 8 9 6 9 0 6 9 1 692.03692.03 245.0-FT 18" RCP 692.78692.78 693.83 696.27 696.16 34.0-FT 18" RCP 691 692 60.5-FT 36" RCP 695.26695.26 694.26 695.26695.26 694.63 695.34 695.15 691.50 693.15 135 125 130 140 145 6-FT DIAMETER PRECAST MANHOLE PROPOSED NCDOT STD. 840.52 115 120 75 PROPOSED 36" RCP QUALITY POND NO. 1 PROPOSED WATER STD. 838.80 ENDWALL PROPOSED NCDOT DROP INLET NCDOT STD. 840.14 PROPOSED CONTROL STRUCTURE PROPOSED 18" RCP CONCRETE COLLAR 18" RCP WITH CONNECT TO STAGE 1 PROPOSED 18" RCP STD. 838.01 ENDWALL PROPOSED NCDOT POND NO. 1 FOR WATER QUALITY PROPOSED FOREBAY STD. 838.80 ENDWALL PROPOSED NCDOT DROP INLET STD 840.14 PROPOSED NCDOT 4-FT DIAMETER PRECAST MANHOLE PROPOSED NCDOT STD. 840.52 PROPOSED 36" RCP CATCH BASIN STD. 840.02 PROPOSED NCDOT NO. 1 UNDERDRAIN PROPOSED NO. 2 UNDERDRAIN PROPOSED PROPOSED 18" RCP PROPOSED 18" RCP ATTENUATOR PROPOSED STORMWATER (APPROX. LOCATION) BE FILLED IN STAGE 2 DITCH LT. OUTFALL TO BYPASS CHANNEL FOR FROM STAGE 1) 140 TO EXISTING BOX (REPLACE WALL PROPOSED 18" RCP FROM STRUCTURE CATCH BASIN STD. 840.02 PROPOSED NCDOT 36 40 72 74 38 689 683.00 682.20 682.77682.77 694.64 694.04694.04 693.44693.44 692.84692.84 692.24692.24 691.64691.64 691.15 197-LF 18" RCP 197-LF 18" RCP 42 46 44 48 76 7 1 4 7 1 5 7 1 6 716 7 1 7 7 1 7 7 1 8 7 1 8 7 1 9 7 1 9 719 7 2 0 7 2 0 720 7 2 1 7 2 1 721 7 2 2 722 722 7 2 3 723 723 724 7 2 4 7 2 4 725 7 2 5 7 2 6 726 7 2 7 728 729 1 3 5 1 4 0 10 1 1 + 0 0 1 2 + 0 0 1 3 + 0 0 1 4 + 0 0 1 5 + 0 0 1 6 + 0 0 6 0 ' P U B L I C R / W P E N M A N S T R E E T 5 0' P U B LI C R / W W E S T S U M M I T A V E . GRAHAM STREET 50' PUBLIC R/W W I N O N A S T R E E T 5 0' P U B L I C R / W M A T C H L I N E P R O P . T R A C K # 5 S T A . 1 2 8 + 0 0 S E E S H E E T 1 B N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL STAGE 2 HYD-2B DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 24.7-FT 18" RCP 715.28 685686687688689690691692 684 684.00 684.81 684.81 57.6-FT 6x6 RCBC 57.6-FT 6x6 RCBC 685.04685.04 684.35 684.00 684.0033.1-FT 18" RCP683.54 688.45 52-FT 36" RCP 690.45 691.07 690 686 687 688 683 684 685 686 687 688 689 690 691 692.03692.03 245.0-FT 18" RCP 692.78692.78 693.83 700.60700.6040.5-FT 18" RCP40.5-FT 18" RCP 700.33700.33 696.27 696.16 34.0-FT 18" RCP 699.68 700.83 700.71 701.84 691 692 60.5-FT 36" RCP 695.26695.26 694.26 695.26695.26 694.63 695.34 695.15 691.50 693.15 689 683.00 682.20 682.77682.77 696.89 694.64694.64 694.04694.04 693.44693.44 692.84692.84 692.24692.24 691.64691.64 691.15 201.6-LF 18" RCP 197-LF 18" RCP 197-LF 18" RCP 714 715 716 716 717 717 718 718 719719 719 720 720 720 721 721 721 722 722 722 723 723 723 724 724 724 725 725 726 726 727 728 729 - TRK6- -TRK 5- -TRK7- -TRK6- -TRK5- 1 1 5 1 2 5 1 3 0 1 3 5 -TRK5- - TRK7- CURVE TRK7-1CURVE TRK6-1CURVE TRK5-2 CURVE TRK5-1 1 2 0 4" PVC S/LCO 700.94 5 4 " W A T E R L I N E R AILR O AD SP U RLI NE R AIL R OAD S P U R LI NE R AILR O A D S P U RLIN E R AIL R O AD M AI N LIN E T R A C K 1 R AI L R OAD M AIN LI N E TR A CK 2 BUILDING (TYPICAL) VICINITY MAP N.T.S. VICINITY MAP N.T.S. VICINITY MAP N.T.S. VICINITY MAP N.T.S. GRAPHIC SCALE PLANS PROFILE (HORIZONTAL) PROFILE (VERTICAL) STATE OF NORTH CAROLINA PLAN FOR PROPOSED EROSION AND SEDIMENT CONTROL MEASURES CONSTRUCTION. GRUBBING PHASE OF FOR CLEARING AND EROSION CONTROL PLANS THIS PROJECT CONTAINS Temporary Silt Ditch Temporary Silt Fence Silt Basin Type B Stilling Basin TDTemporary Diversion Temporary Rock Silt Check Type-B Temporary Rock Silt Check Type-A Temporary Rock Sediment Dam Type-A Temporary Rock Sediment Dam Type-B Type A Type B Type C A B C Temporary Silt Fence TSD Std. #Description Symbol Temporary Berms and Slope Drains Rock Inlet Sediment Trap: 1630.03 1630.05 1605.01 1622.01 1633.01 1634.01 1634.02 1635.01 1635.02 1630.04 1632.01 1632.02 1632.03 Rock Pipe Inlet Sediment Trap Type-A Rock Pipe Inlet Sediment Trap Type-B Temporary Rock Sediment Dam Type A Temporary Rock Sediment Dam Type B Temporary Silt Fence Roadway Standard Drawings The following roadway english standards as appear in "Roadway Standard Drawings"- Roadway Design revison thereto are applicable to this project and by reference hereby are considered a part of these plans. Rock Pipe Inlet Sediment Trap Type A 1606.01 Special Sediment Control Fence 1634.01 1634.02 1635.01 1605.01 1630.01 Temporary Berms and Slope Drains 1606.01 1622.01 Special Sediment Control Fence Riser Basin 1635.02 Rock Pipe Inlet Sediment Trap Type B 1604.01 Railroad Erosion Control Detail 1607.01 Gravel Construction Entrance Skimmer Basin Tiered Skimmer Basin Infiltration Basin Special Stilling Basin1630.06 Temporary Rock Silt Check Type-A with Matting and Polyacrylamide (PAM) Wattle/Coir Fiber Wattle Wattle/Coir Fiber Wattle with Polyacrylamide (PAM) 1630.02 1633.02 Unit - N. C. Department of Transportation - Raleigh, N. C., dated January 2012 and the latest 1630.05 Temporary Diversion 1630.04 Stilling Basin 1630.03 Temporary Silt Ditch 1630.02 Silt Basin Type B 1630.06 Special Stilling Basin 1631.01 Matting Installation 1632.02 1632.01 Rock Inlet Sediment Trap Type B Rock Inlet Sediment Trap Type A 1632.03 Rock Inlet Sediment Trap Type C 1633.01 1633.02 Temporary Rock Silt Check Type B Temporary Rock Silt Check Type A 1640.01 Coir Fiber Baffle 1645.01 Temporary Stream Crossing EW CFW ROADSIDE ENVIRONMENTAL UNIT Raleigh, NC 27611 1 South Wilmington St. 2012 STANDARD SPECIFICATIONS Prepared in the Office of: NAME Reviewed by: Reviewed in the Office of: RESOURCES. RESOURCES DIVISION OF WATER OF ENVIRONMENT AND NATURAL THE NORTH CAROLINA DEPARTMENT AUGUST 3, 2011 AND ISSUED BY CONSTRUCTION PERMIT EFFECTIVE BY THE NCG-010000 GENERAL THE REGULATIONS SET FORTH CONTROL PLANS COMPLY WITH THESE EROSION AND SEDIMENT Designed by: 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 1 4 _ S & E C _ C o v e r . d g n n o r i e g s c PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. L O C O M O T I V E & R A I L C A R M A I N T . F A C I L I T Y N O RTH CAR O LIN A P R OFESS I ON A L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL TYPE OF WORK: GRADING, PAVING, DRAINAGE, & STRUCTURE TO THE LIMITS ESTABLISHED BY METHOD III. CLEARING ON THIS PROJECT SHALL BE PERFORMED E R O S I O N C O N T R O L P L A N S 2012 STANDARD SPECIFICATIONS CHARLOTTE, NC 28202-1144 900 WEST TRADE STREET, SUITE 715 STV ENGINEERS, INC. N A D 8 3 N S R S 2 0 0 7 CONTROL SUBMITTAL PRELIMINARY EROSION X-0XX Submitted X/X/15 STEVEN C. NORIEGA, PE NC PROFESSIONAL REGISTRATION NO. 033404 JEREMY GOODWIN RAIL DIVISION MECKLENBURG COUNTY and Summit Avenue, Charlotte, North Carolina LOCATION: NCDOT LRMF between Carson Street LRMF EROSION CONTROL EC-1 50 50 50 EC-4 thru 9 W E S T S U MM I T A V E NU E N. S. M AI N LI N E STA. 140+72 END PROJECT STA. 116+50 BEGIN PROJECT PROJECT LIMITS PROJECT LOCATION DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 1 5 _ S & E C _ D e t a i l s . d g n s i m m o n b t PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL SITE DESCRIPTION STABILIZATION TIME 7 DAYS TIMEFRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITCHES AND SLOPES HIGH QUALITY WATER (HQW) ZONES 7 DAYS NONE SLOPES STEEPER THAN 3:1 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED. NONE SLOPES 3:1 OR FLATTER 14 DAYS 14 DAYS 7 DAYS FOR SLOPES GREATER THAN 50' IN LENGTH. ALL OTHER AREAS WITH SLOPES FLATTER THAN 4:1 NONE, EXCEPT FOR PERIMETERS AND HQW ZONES. and as directed. accordance with the provisions in this contract ground cover stabilization shall be achieved in land-disturbing activity. Temporary and permanent provided in 14 calendar days from the last temporary or permanent ground cover shall be activity, with the following exceptions in which calendar days from the last land-disturbing ground cover stabilization shall occur within 7 Division of Water Quality. Temporary or permanent Department of Environment and Natural Resources August 3, 2011 issued by the North Carolina NCG-010000 general construction permit effective the time frame guidelines as specified by the Stabilization for this project shall comply with SOIL STABILIZATION REQUIREMENTS EC-2 FLOW A A *T = 12" MIN., 18" MAX. H WIDTH *T PLAN SECTION A-A SECTION B-B B B 2/3 CHANNEL STRUCTURAL STONE SEDIMENT CONTROL STONE 2' MIN 2' MIN L=3xH 12" 1633.01 1633.01 1 1 1 1 T E M P O R A R Y R O C K S I L T C H E C K T Y P E `A ' T E M P O R A R Y R O C K S I L T C H E C K T Y P E ` A ' R A L E I G H , N . C . D I V I S I O N O F H I G H W A Y S D E P T . O F T R A N S P O R T A T I O N N O R T H C A R O L I N A S T A T E O F R A L E I G H , N . C . D I V I S I ON O F H I GH W AY S D E P T . O F T R AN S P O R T A T I ON NO R T H C A R O L I NA S T A T E O F SHEET OF SHEET OF E N G L I S H S T A N D A R D D R A W I N G F O R E NG L I S H S T A N D A R D D R A W I N G F O R CONTROL STONE. USE NO. 5 OR NO. 57 STONE FOR SEDIMENT FOR STRUCTURAL STONE. USE CLASS 'B' EROSION CONTROL STONE NOTE HYDRAULICSROADWAY DESIGN ENGINEER ENGINEER R/W SHEET NO. SHEET NO.PROJECT REFERENCE NO. ISOMETRIC VIEW X-XXXX A MATERIAL FILL OF FILL TOE A GRADE ROAD WATTLE 2 FT. UPSLOPE STAKE FRONT VIEW STAKE 2' WOODEN 2" 15"-16" TOP VIEW EC-2H DOWNSLOPE STAKE TOE OF FILL 18" WATTLE 18" WATTLESEE INSET A 2"-3" TRENCH INSET A FILL SLOPE COIR FIBER WATTLE BARRIER DETAIL FOR BREAKS ALONG LARGE SLOPES, USE MAXIMUM SPACING OF 20 FT. BOTH SIDES OF WATTLE AND AT EACH END TO SECURE IT TO THE SOIL. INSTALL STAPLES APPROXIMATELY EVERY 1 LINEAR FOOT ON FORMED INTO A U SHAPE NOT LESS THAN 12" IN LENGTH. PROVIDE STAPLES MADE OF 0.125 IN. DIAMETER STEEL WIRE STAKES AT AN ANGLE TO WEDGE WATTLE TO GROUND. INSTALL A MINIMUM OF 2 UPSLOPE STAKES AND 4 DOWNSLOPE CROSS SECTION. USE 2 FT. WOODEN STAKES WITH A 2 IN. BY 2 IN. NOMINAL DO NOT PLACE WATTLES ON TOE OF SLOPE. EXCAVATE A 2 TO 3 INCH TRENCH FOR WATTLE TO BE PLACED. WATTLE AND LENGTH OF 10 FT. USE MINIMUM 18 IN. NOMINAL DIAMETER COIR FIBER (COCONUT) NOTES: 1' 4 FT. LTTRACK 5 120+00 128+00 5500 TRACK 5 120+00 128+00 RT 5500 TRACK 5 128+00 137+00 LT TRACK 5 128+00 129+00 RT 450 10000 8300INTERIM DITCH 1250-LF RT TRACK 5 137+00 140+50 LT 10000 EC-6 EC-6 EC-7 EC-7 EC-7 EC-9 EC-9 RCBC OUTFALL 150-LF 1850 1000 42600 42600 45000 STATE OF NORTH CAROLINA DIVISION OF HIGHWAYS SOIL STABILIZATION SUMMARY SHEET (FOR DITCH STABILIZATION) PERMANENT SOIL REINFORCEMENT MAT SHEET NO. CONST LINE STATION FROM STATION TO SIDE ESTIMATE (SY) MISC. PSRM TO BE INSTALLED AS DIRECTED BY ENGINEER. SUBTOTAL SAY TOTAL DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3-B DRAINAGE SUMMARY N O RTH CARO LIN A P R OFESS I ON A L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL 3 / 4 / 2 0 1 6 I : \ V o l 3 \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 3 - B . d g n j o s h i p r PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. DocuSign Envelope ID: 2C49F13A-7049-4347-B41F-0AF13BBBEBC4 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 1 7 _ S & E C _ 1 A C G .d g n n o r i e g s c PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL M A T C H L I N E P R O P . T R A C K # 5 S T A . 12 8 +00 S EE S H EE T E C -5 STAGE 1 EC-4 C C FENCE (TYP) TEMPORARY SILT TYPE C (TYP) SEDIMENT TRAP ROCK INLET INFORMATION PLANS FOR FURTHER SEE ARCHITECTURAL OFFICE BUILDING AREA. PROPOSED FACILITY (TYP) CONTROL FENCE SPECIAL SEDIMENT OF DISTURBANCE APPROXIMATE LIMITS 715.28 24.7-FT 18" RCP 700.60 700.60 699.68 37.0-FT 18" RCP 700 .83 701.84 703.00 702 703 7 0 4 7 02 70 3 7 04 7 0 5 700.71 700.33 700.33 706 707 707 40.5-FT 18" RCP 40.5-FT 18" RCP 702.31 697.90697.90 695.66 699.53 697.56 695.33 696.89 694.64 -TRK7- -TRK6- -TRK5- 1 2 5 -TRK5- CURVE TRK7 - 1 CURV E TRK 6 - 1 CURVE TRK 5 - 2 CURVE TRK5-1 1 2 0 6 9 0 6 9 5 7 0 0 700 7 0 5 705 70 5 705 705 705 705 70 5 705 705 7 1 0 7 1 0 710 710 710 710 710 710 710 710 710 710 7 1 5 715 7 1 5 715 7 1 5 7 1 5 7 1 5 715 715 7 2 0 7 2 0 7 2 0 72 0 7 2 0 7 2 0 7 2 0 7 2 0 72 0 72 0 720 720 7 2 5 7 2 5 725 7 25 725 7 2 5 725 725 7 2 5 7 2 5 7 2 5 7 25 725 7 3 0 7 3 0 7 3 0 730 7 3 0 7 3 0 7 3 0 73 0 73 0 730 7 3 5 7 3 5 73 5 735 7 3 5 74 0 74 0 7407 4 0 74 5 7 4 5 7 4 5 7 4 5 750 7 5 0 SW S W SW SW SW S W S W SW SW HAND HOLE HAND HOLE TVTV TVTV TVTVTVTVTV TV TV SW SS DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 1 8 _ S & E C _ 2 A C G . d g n n o r i e g s c PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL STAGE 1 EC-5 M A T C H L I N E P R O P . T R A C K # 5 S T A . 1 2 8 + 0 0 S E E S H E E T E C - 4 A TYPE-A (TYP) SEDIMENT TRAP ROCK INLET FENCE (TYP) TEMPORARY SILT (TYP) CONTROL FENCE SPECIAL SEDIMENT OF DISTURBANCE APPROXIMATE LIMITS (TYP) CONTROL FENCE SPECIAL SEDIMENT 689.13 687.73 682.25 INTERIM PHASE DITCH @ 0.90% 691.39 97.6-FT 18" RCP 692.03 692.03 245.0-FT 18" RCP 692.78 345.5-FT 18" RCP 693.83 696.27 696.16 692.78 41.0-FT 18" RCP 704705706707 683.09 INTERIM PHASE DITCH @ 1.1% 695.66695.26 694.26 695.26695.26 694.26 695.26695.26 694.26 695.26695.26 694.26 695.33 694.16 695.15695.15 693.65 695.15695.15 694.15 695.15 694.64 197-LF 18" RCP 694.04694.04 197-LF 18" RCP 693.44693.44 692.84692.84 692.24692.24 7 1 4 7 1 4 7 1 5 7 1 5 7 1 6 7 1 6 7 1 6 7 1 6 7 1 7 717 7 1 7 7 1 7 717 7 1 7 7 1 8 7 1 8 718 7 1 8 7 1 8 718 7 1 9 71 9 7 1 9 7 1 9 71 9 7 1 9 7 2 0 720 7 2 0 7 2 0 720 7 2 0 7 2 1 7 21 7 2 1 7 2 1 7 21 7 2 1 72 2 722 72 2 722 723 723 723 723724 7 2 4 724 7 2 4 72 5 725 72 5 725 7 2 6 7 2 6 727727 728728 729729 -TRK6- -TRK5- 1 3 0 1 3 5 -TRK7- 68 0 6 8 5 6 8 5 69 0 690 690 690 690 690 690 69 0 690 690 6 9 0 695 695 695 695 695 695 695 6 9 5 695 695 69 5 70 0 7 0 0 7 0 0 7 0 0 700 7 0 0 700 7 0 0 700 700 7 0 0 700 700 7 0 5 7 0 5 705 705 70 5 705 705 705 705 705 705 70 5 710 710 71 0 7 1 0 7 1 0 710 7 1 0 710 71 0 71 0 710 7 1 0 710 710 7 1 0 7 1 5 715 7 1 5 7 1 5 715 71 5 7 1 5 7 1 5 715 7 1 5 7 1 5 7 1 5 7 1 5 7 2 0 72 0 72 0 SW SW SW SW SW SW SW SW SWSW ST O R A G E P L A TF O R M S CONC CONC CONC S S DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 1 9 _ S & E C _ 1 A F i n a l . d g n n o r i e g s c PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL M A T C H L I N E P R O P . T R A C K # 5 S T A . 12 8 +00 S EE S H EE T E C -7 STAGE 1 EC-6 C C FENCE (TYP) TEMPORARY SILT TYPE C (TYP) SEDIMENT TRAP ROCK INLET INFORMATION PLANS FOR FURTHER SEE ARCHITECTURAL OFFICE BUILDING AREA. PROPOSED FACILITY (TYP) CONTROL FENCE SPECIAL SEDIMENT DRAIN (TYP) TEMPORARY SLOPE WEIR HEIGHT = 1.0' (TYP) SILT CHECK TYPE-A TEMPORARY ROCK TO STATION 130+00 WEIR HEIGHT = 1.0' (TYP) SILT CHECK TYPE-A TEMPORARY ROCK C C TO STATION 129+00 WEIR HEIGHT = 1.0' (TYP) SILT CHECK TYPE-A TEMPORARY ROCK SHOULDER ROAD SLOPE TO EXTEND UP ACCESS 12 S.Y. GEOTEXTILE RIP RAP & 4 TONS CLASS "B" 715.28 24.7-FT 18" RCP 700.60 700.60 699.68 37.0-FT 18" RCP 700 .83 701.84 703.00 702 703 7 0 4 7 02 70 3 7 04 7 0 5 700.71 700.33 700.33 706 707 707 40.5-FT 18" RCP 40.5-FT 18" RCP 702.31 697.90697.90 695.66 699.53 697.56 695.33 696.89 694.64 -TRK7- -TRK6- -TRK5- 1 2 5 -TRK5- CURVE TRK7 - 1 CURV E TRK 6 - 1 CURVE TRK 5 - 2 CURVE TRK5-1 1 2 0 6 9 0 6 9 5 7 0 0 700 7 0 5 705 70 5 705 705 705 705 70 5 705 705 7 1 0 7 1 0 710 710 710 710 710 710 710 710 710 710 7 1 5 715 7 1 5 715 7 1 5 7 1 5 7 1 5 715 715 7 2 0 7 2 0 7 2 0 72 0 7 2 0 7 2 0 7 2 0 7 2 0 72 0 72 0 720 720 7 2 5 7 2 5 725 7 25 725 7 2 5 725 725 7 2 5 7 2 5 7 2 5 7 25 725 7 3 0 7 3 0 7 3 0 730 7 3 0 7 3 0 7 3 0 73 0 73 0 730 7 3 5 7 3 5 73 5 735 7 3 5 74 0 74 0 7407 4 0 74 5 7 4 5 7 4 5 7 4 5 750 7 5 0 SW S W SW SW SW S W S W SW SW HAND HOLE HAND HOLE TVTV TVTV TVTVTVTVTV TV TV SW SS DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 0 _ S & E C _ 2 A F i n a l . d g n n o r i e g s c PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL STAGE 1 EC-7 M A T C H L I N E P R O P . T R A C K # 5 S T A . 1 2 8 + 0 0 S E E S H E E T E C - 6 A TYPE-A (TYP) SEDIMENT TRAP ROCK INLET FENCE (TYP) TEMPORARY SILT (TYP) CONTROL FENCE SPECIAL SEDIMENT TO STATION 134+00 WEIR HEIGHT = 1.5' (TYP) SILT CHECK TYPE-A TEMPORARY ROCK TO PROJECT END WEIR HEIGHT = 2.0' (TYP) SILT CHECK TYPE-A TEMPORARY ROCK C C 7 S.Q. GEOTEXTILE RIP RIP & 2 TONS CLASS "B" 12 S.Y. GEOTEXTILE RIP RAP & 4 TONS CLASS "B" 12 S.Y. GEOTEXTILE RIP RAP & 4 TONS CLASS "B" (TYP) CONTROL FENCE SPECIAL SEDIMENT (TYP) TOP OF DITCH DRAIN TO FOLLOW TEMPORARY SLOPE 689.13 687.73 682.25 INTERIM PHASE DITCH @ 0.90% 691.39 97.6-FT 18" RCP 692.03 692.03 245.0-FT 18" RCP 692.78 345.5-FT 18" RCP 693.83 696.27 696.16 692.78 41.0-FT 18" RCP 703704705706707 683.09 INTERIM PHASE DITCH @ 1.1% 695.66695.26 694.26 695.26695.26 694.26 695.26695.26 694.26 695.26695.26 694.26 695.33 694.16 695.15695.15 693.65 695.15695.15 694.15 695.15 694.64 197-LF 18" RCP 694.04694.04 197-LF 18" RCP 693.44693.44 692.84692.84 692.24692.24 7 1 4 7 1 4 7 1 5 7 1 5 7 1 6 7 1 6 7 1 6 7 1 6 7 1 7 717 7 1 7 7 1 7 717 7 1 7 7 1 8 7 1 8 718 7 1 8 7 1 8 718 7 1 9 71 9 7 1 9 7 1 9 71 9 7 1 9 7 2 0 720 7 2 0 7 2 0 720 7 2 0 7 2 1 7 21 7 2 1 7 2 1 7 21 7 2 1 72 2 722 72 2 722 723 723 723 723724 7 2 4 724 7 2 4 72 5 725 72 5 725 7 2 6 7 2 6 727727 728728 729729 -TRK6- -TRK5- 1 3 0 1 3 5 -TRK7- 68 0 6 8 5 6 8 5 6 8 5 69 0 690 690 690 690 690 690 69 0 690 690 6 9 0 695 695 695 695 695 695 695 6 9 5 695 695 69 5 70 0 7 0 0 7 0 0 7 0 0 700 7 0 0 700 7 0 0 700 700 7 0 0 700 700 700 7 0 5 7 0 5 705 705 70 5 705 705 705 705 705 705 70 5 710 710 71 0 7 1 0 7 1 0 710 7 1 0 710 71 0 71 0 710 7 1 0 710 710 7 1 0 7 1 5 715 7 1 5 7 1 5 715 71 5 7 1 5 7 1 5 715 7 1 5 7 1 5 7 1 5 7 1 5 7 2 0 72 0 72 0 SW SW SW SW SW SW SW SW SWSW ST O R A G E P L A TF O R M S CONC CONC CONC S S DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 1 _ S & E C _ S t a g e 2 C G . d g n n o r i e g s c PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL STAGE 2 EC-8 C A (TYP) CONTROL FENCE SPECIAL SEDIMENT TYPE C (TYP) SEDIMENT TRAP ROCK INLET C C FOR STAGE 2 LIMITS OF DISTURBANCE FOR STAGE 1 LIMITS OF DISTURBANCE FOR STAGE 1 TEMPORARY SILT FENCE STAGE 1 TYPE-A FOR SEDIMENT TRAP ROCK INLET FROM STAGE 1 SILT CHECK TYPE-A TEMPORARY ROCK 685 686687 688689690691692 684 684.00 684.81 684.81 57.6-FT 6x6 RCBC 57.6-FT 6x6 RCBC 685.04 685.04 684.35 684.00 684.00 33.1-FT 18" RCP 683.54 688.45 52-FT 36" RCP 690.45 691.07 690 686 687 688 6 8 3 6 8 4 6 8 5 6 8 6 6 8 7 6 8 8 6 8 9 6 9 0 6 9 1 692.03692.03 245.0-FT 18" RCP 692.78692.78 693.83 696.27 696.16 34.0-FT 18" RCP 691 692 60.5-FT 36" RCP 695.26695.26 694.26 695.26695.26 694.63 695.34 695.15 691.50 693.15 689 683.00 682.20 682.77682.77 694.64 694.04694.04 693.44693.44 692.84692.84 692.24692.24 691.64691.64 691.15 197-LF 18" RCP 197-LF 18" RCP 7 1 4 7 1 5 7 1 6 716 7 1 7 7 1 7 7 1 8 7 1 8 7 1 9 7 1 9 719 7 2 0 7 2 0 720 7 2 1 7 2 1 721 7 2 2 722 722 7 2 3 723 723 724 7 2 4 7 2 4 725 7 2 5 7 2 6 726 7 2 7 728 729 TRK6-2 CURVE -TRK5- 1 4 0 -TRK7- -TRK6- 1 3 0 -TRK5- 1 3 5 68 0 6 8 5 6 8 5 6 8 5 69 0 690 690 690 690 690 690 69 0 690 690 6 9 0 695 695 695 695 695 695 695 6 9 5 695 695 69 5 70 0 7 0 0 7 0 0 7 0 0 700 7 0 0 700 7 0 0 700 700 7 0 0 700 700 700 7 0 5 7 0 5 705 705 70 5 705 705 705 705 705 705 70 5 710 710 71 0 7 1 0 7 1 0 710 7 1 0 710 71 0 71 0 710 7 1 0 710 710 7 1 0 7 1 5 715 7 1 5 7 1 5 715 71 5 7 1 5 7 1 5 715 7 1 5 7 1 5 7 1 5 7 1 5 7 2 0 72 0 72 0 SW SW SW SW SW SW SW SW SWSW ST O R A G E P L A TF O R M S CONC CONC CONC S S DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ P l o t S h e e t s \ 4 0 1 5 1 5 6 _ S H T _ 2 2 _ S & E C _ S t a g e 2 F i n a l . d g n n o r i e g s c PROJECT REFERENCE NO.SHEET NO. R/W SHEET NO. RAIL DESIGN ENGINEER HYDRAULICS ENGINEER D C N P-2918F NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. N O RTH CAR O LIN A P R OFESS I ONA L E NGINEER S T E V E N C H R ISTOPHER NOR I E G A033404 SEAL STAGE 2 EC-9 A C 695.92 C CLEARING & GRUBBING FROM STAGE 2 CONTROL FENCE SPECIAL SEDIMENT DURING CONSTRUCTION AS A SEDIMENT DAM POND TO BE CONFIGURED PROPOSED DETENTION TO PROJECT END WEIR HEIGHT = 2.0' (TYP) SILT CHECK TYPE-A TEMPORARY ROCK FOR FINAL GRADES SEE CROSS SECTIONS AREA TO BE REGRADED 22 S.Y. GEOTEXTILE 7 TONS CLASS "B" RIP RAP GEOTEXTILE RIP RAP & 7 S.Y. 2 TONS CLASS "B" 110 S.Y. GEOTEXTILE 50 TONS CLASS "B" RIP RAP DRAIN FOR STAGE 2 TEMPORARY SLOPE FROM STAGE 1 TEMPORARY SILT FENCE FROM STAGE 1 LIMITS OF CONSTRUCTIONFROM STAGE 1 SILT CHECK TYPE-A TEMPORARY ROCKSTAGE 1 TYPE-A FROM SEDIMENT TRAP ROCK INLET 22 S.Y. GEOTEXTILE 7 TONS CLASS "B" RIP RAP FROM STAGE 1 SILT CHECK TYPE-A TEMPORARY ROCK FROM STAGE 1 TEMPORARY SILT FENCE STAGE 1 TRAP TYPE-C FROM ROCK INLET SEDIMENT FROM STAGE 1 CONTROL FENCE SPECIAL SEDIMENT FROM STAGE 1 LIMITS OF CONSTRUCTION DRAIN FROM STAGE 1 TEMPORARY SLOPE 685 686687 688689690691692 684 684.00 684.81 684.81 57.6-FT 6x6 RCBC 57.6-FT 6x6 RCBC 685.04 685.04 684.35 684.00 684.00 33.1-FT 18" RCP 683.54 688.45 52-FT 36" RCP 690.45 691.07 690 686 687 688 6 8 3 6 8 4 6 8 5 6 8 6 6 8 7 6 8 8 6 8 9 6 9 0 6 9 1 692.03692.03 245.0-FT 18" RCP 692.78692.78 693.83 696.27 696.16 34.0-FT 18" RCP 691 692 60.5-FT 36" RCP 695.26695.26 694.26 695.26695.26 694.63 695.34 695.15 691.50 693.15 689 683.00 682.20 682.77682.77 694.64 694.04694.04 693.44693.44 692.84692.84 692.24692.24 691.64691.64 691.15 197-LF 18" RCP 197-LF 18" RCP 7 1 4 7 1 5 7 1 6 716 7 1 7 7 1 7 7 1 8 7 1 8 7 1 9 7 1 9 719 7 2 0 7 2 0 720 7 2 1 7 2 1 721 7 2 2 722 722 7 2 3 723 723 724 7 2 4 7 2 4 725 7 2 5 7 2 6 726 7 2 7 728 729 TRK6-2 CURVE -TRK5- 1 4 0 -TRK7- -TRK6- 1 3 0 -TRK5- 1 3 5 68 0 6 8 5 6 8 5 6 8 5 69 0 690 690 690 690 690 690 69 0 690 690 6 9 0 695 695 695 695 695 695 695 6 9 5 695 695 69 5 70 0 7 0 0 7 0 0 7 0 0 700 7 0 0 700 7 0 0 700 700 7 0 0 700 700 700 7 0 5 7 0 5 705 705 70 5 705 705 705 705 705 705 70 5 710 710 71 0 7 1 0 7 1 0 710 7 1 0 710 71 0 71 0 710 7 1 0 710 710 7 1 0 7 1 5 715 7 1 5 7 1 5 715 71 5 7 1 5 7 1 5 715 7 1 5 7 1 5 7 1 5 7 1 5 7 2 0 72 0 72 0 SW SW SW SW SW SW SW SW SWSW ST O R A G E P L A TF O R M S CONC CONC CONC S S DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469 3/4/2016 DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 690 690 116+00.00 710 710 720 720 700 700 116+50.00 710 710 720 720 700 700 117+00.00 X-1 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K (T O R E M A I N ) C / L E X I S T . S I D I NG T R A C K (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W (R E M A I N ) E X I S T . F E N C E C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W C /L P R O P . T R A C K # 5 (T O B E S H I F T E D ) C / L E X I S T . S I D I N G T R A C K (R E M A I N ) E X I S T . F E N C E EXIST GROUND LINE 7 0 7 .9 4 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W C /L P R O P . T R A C K # 5 (T O B E S H I F T E D ) C / L E X I S T . S I D I N G T R A C K (R E M A I N ) E X I S T . F E N C E EXIST GROUND LINE REQUESTED SURVEY ADDITIONAL 7 0 7 .6 5 TO DRAIN TYPICAL. LOCATION. GRADE AREA INLET - APPROX. EXISTING DRAINAGE DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 710 710 720 720 730 730 740 740 750 750 760 760 700 700 117+50.00 710 710 720 720 730 730 740 740 750 750 760 760 700 700 118+00.00 X-2 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W C /L P R O P . T R A C K # 5 (T O B E S H I F T E D ) C / L E X I S T . S I D I NG T R A C K (R E M A I N ) E X I S T . F E N C E EXIST GROUND LINE 7 0 7 .4 9 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E S H I F T E D ) C / L E X I S T . S I D I N G T R A C K C /L P R O P . T R A C K # 5 EXIST GROUND LINE 7 0 7 . 4 6 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 710 710 720 720 730 730 740 740 750 750 760 760 700 700 118+50.00 700 700 710 710 720 720 730 730 740 740 750 750 760 760 119+00.00 X-3 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E S H I F T E D ) C / L E X I S T . S I D I NG T R A C K 40:1 EXIST GROUND LINE 7 0 7 .5 1 WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER CRASHWALL TO FACE OF 15.03' NEW 15" RCP. & REPLACE WITH LOCATION. REMOVE INLET - APPROX. EXISTING DRAINAGE 705.41 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E S H I F T E D ) C / L E X I S T . S I D I NG T R A C K 40:1 EXIST GROUND LINE 7 0 7 . 5 5 WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER CRASHWALL TO FACE OF 16.79' 705.25 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 740 740 750 750 690 690 119+50.00 710 710 720 720 730 730 740 740 750 750 700 700 120+00.00 X-4 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E S H I F T E D ) C / L E X I S T . S I D I NG T R A C K 40:1 EXIST GROUND LINE 7 0 7 .5 9 WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER CRASHWALL TO FACE OF 18.49' 705.17 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 2:1 2: 1 2:1 (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K 40:140:1 EXIST GROUND LINE 7 0 7 . 6 3 IN THIS AREA TYPICAL. AREA. GRADE TO DRAIN IS LOCATED IN THIS DRAINAGE STRUCTURE CONFIRM THAT A CONTRACTOR TO EXISTING LOW AREA. 704.50 706.622: 1 704.00 709.13 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 710 710 720 720 730 730 740 740 750 750 700 700 120+50.00 710 710 720 720 730 730 740 740 750 750 700 700 121+00.00 X-5 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 2:1 2: 1 2:1 (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K 40:140:1 EXIST GROUND LINE 7 0 7 .5 6 706.17 704.44 2: 1 704.50 716.46 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K 40:140:1 EXIST GROUND LINE (R E M A I N ) E X I S T . B U I L D I NG (R E M A I N ) E X I S T . B U I L D I NG 7 0 7 .2 7 2:1 2: 1 WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER 706.00 704.14 705.73 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 740 740 690 690 121+50.00 710 710 720 720 730 730 700 700 122+00.00 700 700 710 710 720 720 730 730 122+50.00 X-6 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 2: 1 2:1 REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K 40:1 40:1 EXIST GROUND LINE 7 0 6 .7 6 2: 1 2:1 WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER CRASHWALL TO FACE OF 12.80' 706.33 703.63703.03 705.19 C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 40:140:1 2: 1 1:1 (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 6 (R E M A I N ) E X I S T . F E N C E P R O P . F E N C E EXIST GROUND LINE 7 0 6 .14 2 WALL NORTH SIDE OF CRASH INCOMING DITCH FROM ROAD ACCESS PROP. 10' 708.16 702.45 2:1 703.48 2: 1 710.44 50:1 50:1 705.58 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 1:140:1 40:1 2: 1 2:1 (B Y O T H E R S ) C /L F U T U R E T R A C K (R E M A I N ) E X I S T . F E N C E E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 7 0 5 .5 1 (R E M OV E D ) E X I S T . W A LL 720.00 710.45 ROAD ACCESS PROP. 10' 708.28 701.88 2:1 50:1 702.54 2: 1 709.91 50:1 704.96 7 0 5 .5 1 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 690 690 123+00.00 700 700 710 710 720 720 730 730 690 690 123+50.00 700 700 710 710 720 720 730 730 690 690 123+71.54 X-7 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K P R O P . F E N C E P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 40:1 2: 1 2:1 (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W (R E M A I N ) E X I S T . F E N C E E X I S T . R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K EXIST GROUND LINE (R E M A I N ) E X I S T . F E N C E (R E M A I N ) E X I S T . F E N C E (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . F E N C E 7 0 4 .8 91:1 (R E M OV E D ) E X I S T . W A LL ROAD ACCESS PROP. 10' 701.30 708.20 2:1 701.61 2: 1 709.63 50:1 704.34 C / L E X I S T . M A I N T R A C K P R O P . F E N C E P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 2:1 WALL PROP. RET. (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W C /L P R O P . T R A C K # 7 (R E M OV E ) E X I S T . F E N C E E X I S T . R / W 2: 1 PROP. ACCESS ROAD EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . F E N C E 40:1 (R E M A I N ) E X I S T . W A LL 7 0 4 .2 61:1 708.44 700.73 2:1 700.68 2: 1 710.10 50:150:1 703.71 40:1 PROP. ACCESS ROAD P R O P . F E N C E C /L P R O P . T R A C K # 7 C /L P R O P . T R A C K # 6 2:1 2: 1 E X I S T . N S R R / W 40:1 C /L P R O P . T R A C K # 5 WALL PROP. RET. P R O P . R O W EXIST GROUND LINE (R E M A I N ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . F E N C E 8:1 WALKWAY PROP. (R E M OV E ) E X I S T . F E N C E 7 0 3 .9 91:1 708.79 700.48700.32 7 0 4 .8 9 7 0 4 .2 6 7 0 3 .9 8 7 0 3 . 9 8 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 690 690 124+00.00 700 700 710 710 720 720 730 730 690 690124+50.00 700 700 710 710 720 720 730 730 690 690125+00.00 X-8 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 40:1 40:1 PROP. ACCESS ROAD WALL PROP. RET. E X I S T . N S R R / W (B Y O T H E R S ) C /L F U T U R E T R A C K 2:1 2: 1 P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . F E N C E 7 0 3 .6 4 BUILDING FOR PROP. PROP. FFE 1:150:1 708.99 700.15 711.21 700.35 4 2:1 703.35 P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 40:1 1:1 2:1 E X I S T . N S R R / W 40:1 P R O P . F E N C E 8:1 WALL PROP. RET. P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . F E N C E 7 0 3 .0 2 BUILDING FOR PROP. PROP. FFE 2: 1 50:11:1 50 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 710.71 699.58 2:1 699.96 2: 1 713.62 50:1 698.76 702.26 P R O P . F E N C E C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 40:1 1:1 2:1 WALL PROP. RET. E X I S T . N S R R / W 40:1 P R O P . F E N C EPRO P . R O W EXIST GROUND LINE 7 0 2 . 3 9 C /L P R O P . T R A C K # 5 BUILDING FOR PROP. PROP. FFE 2: 1 8:150:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 714.10 699.24 2:150:1 698.14699.76 716.43 701.64 7 0 3 .6 3 7 0 3 .6 3 7 0 3 .0 1 7 0 3 .0 1 7 0 2 .4 2 7 0 2 . 4 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 690 690125+07.33 700 700 710 710 720 720 730 730 690 690125+50.00 700 700 710 710 720 720 730 730 690 690126+00.00 X-9 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS 2:11:1C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 4' DIAMETER PRECAST MANHOLE NCDOT STD. 840.52 EXISTING 18" RCP APPROX. INV ELEV. = 715.28 P R O P . F E N C EPRO P . F E N C E E X I S T . N S R R / W EXIST GROUND LINE (R E M OV E ) E X I S T . B U I L D I NG 7 0 2 . 3 0 C /L P R O P . T R A C K # 5 8:1 2: 1 50:1 4' DIAMETER PRECAST MANHOLE NCDOT STD. 840.52 717.80MATCH EXISTING GRADE 718.20 +/- ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 714.00 699.19 701.84 700.83 700.71 PROPOSED 18" RCP 699.68 2: 1 2:150:1 698.04 CIVIL SITE PLANS BUILDING GENERAL WITH PROPOSED COORDINATE PROP. RET. WALLGENERAL CIVIL SITE PLANS PROPOSED BUILDING COORDINATE WITH FROM OFFICE BUILDING PROPOSED 18" RCP 701.55 P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:140:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINE (R E M A I N ) E X I S T . B U I L D I N G C /L P R O P . T R A C K # 5 7 0 1 . 7 7 8:1 2: 1 50:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 712.17 698.91 2:1 50:1 697.51 699.25 2: 1 717.12 701.02 P R O P . F E N C E P R O P . F E N C E 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINEC /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 7 0 1 .14 8:1 2: 1 50:1 8 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 710.56 698.58 2:1 698.73 2: 1 716.57 696.89 50:1 CONCRETE CATCH BASIN NCDOT STD. 840.02 52 700.39 7 0 2 .3 7 7 0 2 .3 9 7 0 1 .8 3 7 0 1 .8 4 7 0 1 .2 3 7 0 1 .2 7 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 690 690126+50.00 700 700 710 710 720 720 730 730 740 740 690 690 127+00.00 700 700 710 710 720 720 730 730 690 690 127+50.00 X-10 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINE 7 0 0 .5 2 8:1 2: 1 50:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 709.89 698.24 710.00 708.00 710.71 2:150:1 698.22 696.33 699.77 P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINE (R E M A I N ) E X I S T . F E N C E 6 9 9 .9 0 2: 1 8:150:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 709.03 697.91 707.00 702.00 2:1 2: 1 697.71 50:1 709.92 BERM PROP. 5' 695.64 699.14 P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINE (R E M A I N ) E X I S T . W A LL (R E M A I N ) E X I S T . F E N C E 6 9 9 .3 2 8:1 2: 1 50:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10'705.60 697.58 702.00 707.00 2:150:1 695.07 2: 1 697.19 708.65 BERM PROP. 5' 698.57 7 0 0 . 6 4 7 0 0 .7 0 7 0 0 .0 5 7 0 0 .13 6 9 9 .4 5 6 9 9 .5 3 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 690 690128+00.00 700 700 710 710 720 720 690 690 128+50.00 690 690 700 700 710 710 720 720 129+00.00 690 690 700 700 710 710 720 720 129+50.00 X-11 5 10 P-2918F -TRK5- STAGE 1CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 6 9 8 .9 0 8:1 2: 1 50:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 702.45 697.24 707.00 702.00 2:150:1 694.64 696.68 2: 1 707.88 BERM PROP. 5' CONCRETE CATCH BASIN NCDOT STD. 840.02 12 54 698.15 P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:140:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K 2:1 EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 6 9 8 .6 3 8:12: 1 702.00 50:1 707.00 DROP INLET TRAFFIC BEARING GRATED NCDOT STD. 840.36 705.00 ELEV. 702.00 1" ORIFICE @ ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 701.00 696.91 696.26 696.16 696.16 2: 1 707.00 2:150:1 HDPE - TYPICAL & PERFORATED 6" SMOOTH WALL BERM PROP. 5' 694.49 PROPOSED 18" RCP 697.88 C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . F E N C E EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 6 9 8 . 5 2 8:1 2: 1 50:1 56 TYPICAL CLEANOUT PIPE HDPE HEADER 6" SMOOTH WALL ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 700.39 693.83 1.5:12:12: 1 695.65 702.10 50:1 694.34 696.58 697.97 P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 1:1 40:1 E X I S T . N S R R / W 40:1 (R E M OV E ) E X I S T . F E N C E (B Y O T H E R S ) C /L F U T U R E T R A C K C /L P R O P . T R A C K # 7 1:1 EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 6 9 8 .5 2 45:1 BY OTHERS OIL-WATER SEPARATOR @ 1.0% TYPICAL DISCHARGE PIPE 6" DIP DRIP PAN HDPE - TYPICAL & PERFORATED 6" SMOOTH WALL ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 1.5:1 8:1 2: 1 693.68 2:1 695.18 2: 1 702.06 50:1 694.19 696.69 697.84 6 9 8 .9 9 6 9 9 .0 5 6 9 8 .6 9 6 9 8 .7 2 6 9 8 . 5 4 6 9 8 .5 5 6 9 8 .5 2 6 9 8 .5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 680 680129+85.69 690 690 700 700 710 710 720 720 680 680 130+00.00 690 690 700 700 710 710 720 720 730 730 130+50.00 X-12 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C /L P R O P . T R A C K # 7 40:1 C /L P R O P . T R A C K # 6 1:140:1 EXISTING 48" RCP (TO REMAIN) P R O P . F E N C E E X I S T . N S R R / W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 6 9 8 .5 2C /L P R O P . T R A C K # 5 41.5:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 699.99 1.5:1 8:1 2: 1 693.57 2:1 50:12: 1 694.85 701.91 694.08 EXISTING 48" RCP (TO REMAIN) - APPROX. LOCATION 696.76 697.75 C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (R E M OV E ) E X I S T . F E N C E (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . F E N C E C /L P R O P . T R A C K # 7 EXIST GROUND LINE 6 9 8 .5 2 8:140:1 16 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 1.5:1 2: 1 693.53 701.92 2:1 694.72 2: 1 50:1 CONCRETE CATCH BASIN NCDOT STD. 840.02 694.04 696.79 697.72 P R O P . F E N C E E X I S T . B U I L D I NG C / L E X I S T . M A I N T R A C K E X I S T . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 6 9 8 .5 2 8:135:1 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 1.5:1 2: 1 693.38694.25 2: 1 701.99 2:1 50:1 693.89 696.90 697.84 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 730 730 680 680 131+00.00 690 690 700 700 710 710 720 720 730 730 131+50.00 700 700 710 710 720 720 730 730 690 690 132+00.00 X-13 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 1:140:1 1:1 E X I S T . N S R R / W 40:1 (R E M OV E ) E X I S T . F E N C E (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 6 9 8 . 5 2 8:1 30:1 18 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 1.5:1 2: 1 693.23693.79 2: 1 703.15 2:1 50:1 693.74 58 697.01 697.97 P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (R E M OV E ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . B U I L D I NG (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 6 9 8 . 5 2 8:1 25:1 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 706.29 1.5:1 2: 1 693.08 SIDEWALK PROP. 10' 2:1 50:1 693.32 2: 1 50:1 693.59 697.11 697.84 C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 1:1 E X I S T . N S R R / W 40:140:1 (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . B U I L D I NG (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . F E N C E P R O P . R O W EXIST GROUND LINE (R E M A I N ) E X I S T . B U I L D I N G (R E M OV E ) E X I S T . F E N C E 6 9 8 . 5 2 8:1 20:1 22 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 1.5:1 692.93 50:150:1 2:1 692.86 2: 1 706.72 CONCRETE CATCH BASIN NCDOT STD. 840.02 693.44 697.22 697.72 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 690 690 132+50.00 700 700 710 710 720 720 730 730 690 690 133+00.00 690 690 700 700 710 710 720 720 730 730 133+50.00 X-14 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (R E M OV E ) E X I S T . B U I L D I N G (R E M OV E ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . F E N C E (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 6 9 8 . 5 2 8:115:1 62 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 692.78 1.5:1 2:1 50:1 2: 1 692.39 707.64 693.29 697.05 697.84 P R O P . F E N C E C / L E X I S T . M A I N T R A C K 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C KPRO P . R O W EXIST GROUND LINE (R E M A I N ) E X I S T . B U I L D I N G 6 9 8 . 5 2 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 5 8:1 20:1 24 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 706.09 712.75 1.5:1 2: 1 692.63 2:1 50:1 2: 1 691.93 693.14 697.00 697.97 P R O P . F E N C E C / L E X I S T . M A I N T R A C K 40:1 1:1 E X I S T . N S R R / W 40:1 (R E M OV E ) E X I S T . F E N C E (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W P R O P . R O W EXIST GROUND LINE (R E M A I N ) E X I S T . B U I L D I NG 6 9 8 . 5 2 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 5 8:1 25:1 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10'704.42 712.63 1.5:1 2: 1 692.48 2:1 2: 1 691.46 50:1 692.99 696.90 697.84 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 730 730 740 680 680 134+00.00 690 690 700 700 710 710 720 720 680 134+50.00 690 690 700 700 710 710 720 720 730 730 680 680 135+00.00 X-15 5 10 P-2918F -TRK5- STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . F E N C E (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W P R O P . R O W EXIST GROUND LINE (R E M A I N ) E X I S T . B U I L D I NG 6 9 8 . 5 2 8:1 30:1 28 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 704.84 712.73 1.5:1 2: 1 692.33 50:1 2:1 2: 1 691.00 CONCRETE CATCH BASIN NCDOT STD. 840.02 692.84 64 696.79 697.72 P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (R E M OV E ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . F E N C E (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . B U I L D I N G 6 9 8 . 5 2 8:1 35:1 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 711.93 1.5:1 2: 1 692.18 2: 1 690.53 2:1 50:1 692.69 696.68 697.84 P R O P . F E N C E C / L E X I S T . M A I N T R A C K 40:1 1:1 E X I S T . N S R R / W 40:1 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 5 (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . B U I L D I NG (B Y O T H E R S ) C /L F U T U R E T R A C K 695.35 P R O P . R O W P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 6 9 8 . 5 2 702.19 8:140:1 30 68 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 702.32 710.86 1.5:1 2: 1 692.03 50:1 2:1 690.06 2: 1 692.54 696.57 697.97 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120 120 130 130 140 140 150 150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 680 680 135+50.00 690 690 700 700 710 710 720 720 680 680 136+00.00 690 690 700 700 710 710 720 720 730 730 680 680 136+50.00 X-16 5 10 P-2918F -TRK5- 160 170 180 190 160 170 180 190 STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K P R O P . F E N C E C / L E X I S T . M A I N T R A C K 40:1 E X I S T . N S R R / W 40:1 C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 (R E M OV E ) E X I S T . B U I L D I NG 1:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . F E N C E 6 9 8 . 5 2 8:145:1 BY OTHERS OIL-WATER SEPARATOR @ 1.0% TYPICAL DISCHARGE PIPE 6" DIP DRIP PAN ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 702.74 710.11 1.5:1 2: 1 691.71 50:1 2:1 2: 1 689.60 692.39 696.47 697.84 C / L E X I S T . M A I N T R A C K P R O P . F E N C E C / L E X I S T . M A I N T R A C K 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 (R E M OV E ) E X I S T . F E N C E 6 9 8 . 5 2 8:150:1 34 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 706.80 701.60 691.39 2:1 2: 1 689.13 50:1 1.5:1 1.5:1 CONCRETE CATCH BASIN NCDOT STD. 840.02 692.24 70 697.72 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K E X I S T . N S R R / W (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W (R E M OV E ) E X I S T . F E N C E (R E M A I N ) E X I S T . F E N C E 1.5:1 1.5:1 687.44 699.21 700.27 707.04 6 9 8 . 5 2 6 9 8 . 5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 90 90 100 100 110 110 120 120 130 130 140 140 150 150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 680 680 136+73.83 690 690 700 700 710 710 680 680 137+00.00 690 690 700 700 710 710 720 720 680 680 137+50.00 X-17 5 10 P-2918F -TRK5- 160 170 180 190 200 210 220 160 170 180 190 200 210 220 STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS E X I S T . N S R R / W P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E (R E M A I N ) E X I S T . F E N C E (R E M A I N ) E X I S T . B U I L D I N G 1.5:1 1.5:1 687.17 701.58 700.08 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K E X I S T . N S R R / W (B Y O T H E R S ) C /L F U T U R E T R A C KPRO P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E (R E M A I N ) E X I S T . F E N C E (R E M A I N ) E X I S T . B U I L D I N G 1.5:1 1.5:1 699.54 686.87 701.93 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K E X I S T . N S R R / W (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E (R E M A I N ) E X I S T . F E N C E 1.5:1 1.5:1 698.12 686.29 703.15 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 90 90 100 100 110 110 120 120 130 130 140 140 150 150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 680 680 138+00.00 690 690 700 700 710 710 720 720 680 680 138+50.00 690 690 700 700 710 710 720 720 680 680 139+00.00 X-18 5 10 P-2918F -TRK5- 160 160 170 170 180 180 190 190 200 200 210 210 220 220 STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K E X I S T . N S R R / W (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E (R E M A I N ) E X I S T . F E N C E 1.5:1 1.5:1 693.03 706.27 685.72 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K E X I S T . N S R R / W (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 1.5:1 1.5:1690.02 685.15 707.38 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K E X I S T . N S R R / W (R E M OV E ) E X I S T . F E N C E (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 1.5:1 1.5:1 690.00 684.57 706.61 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 90 90 100 100 110 110 120 120 130 130 140 140 150 150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 680 680 139+50.00 690 690 700 700 710 710 720 720 680 680 139+65.20 690 690 700 700 710 710 720 720 680 680 140+00.00 X-19 5 10 P-2918F -TRK5- 160 170 180 190 200 210 220 160 170 180 190 200 210 220 STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C KE X I S T . N S R R / W (R E M OV E ) E X I S T . B U I L D I NG (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . B U I L D I N G (R E M OV E ) E X I S T . F E N C E 1.5:1 1.5:1 697.11 689.66 684.00 E X I S T . N S R R / W P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . B U I L D I N G(R E M OV E ) E X I S T . B U I L D I NG 1.5:1 1.5:1 689.76 683.83 698.81 E X I S T . N S R R / W (R E M OV E ) E X I S T . B U I L D I N G (B Y O T H E R S ) C /L F U T U R E T R A C KPRO P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E (R E M OV E ) E X I S T . B U I L D I NG 1.5:1 1.5:1689.19 696.32 683.43 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 90 90 100 100 110 110 120 120 130 130 140 140 150 150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 A . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 680 680140+18.00 690 690 700 700 710 710 720 720 680 680 140+50.00 690 690 700 700 710 710 720 720 680 680140+72.48 X-20 5 10 P-2918F -TRK5- 160 170 180 190 200 210 220 160 170 180 190 200 210 220 STAGE 1 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS E X I S T . N S R R / W P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . B U I L D I N G (R E M OV E ) E X I S T . F E N C E 1.5:1 1.5:1689.00 694.93 683.22 P R O P . F E N C E E X I S T . N S R R / W (R E M OV E ) E X I S T . B U I L D I N G (R E M OV E ) E X I S T . B U I L D I N G (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E 694.44 1.5:1 1.5:1688.72 694.00 682.86 E X I S T . N S R R / W P R O P . R O W P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . B U I L D I NG (R E M A I N ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . F E N C E 2:1 692.90 688.83 682.61 692.91 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 690 690 116+00.00 710 710 720 720 700 700 116+50.00 710 710 720 720 700 700 117+00.00 X-21 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K (T O R E M A I N ) C / L E X I S T . S I D I NG T R A C K (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W C /L P R O P . T R A C K # 5 (T O B E S H I F T E D ) C / L E X I S T . S I D I N G T R A C K EXIST GROUND LINE 7 0 7 .9 4 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W C /L P R O P . T R A C K # 5 (T O B E S H I F T E D ) C / L E X I S T . S I D I N G T R A C K EXIST GROUND LINE REQUESTED SURVEY ADDITIONAL 7 0 7 .6 5 TO DRAIN TYPICAL. LOCATION. GRADE AREA INLET - APPROX. EXISTING DRAINAGE DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 710 710 720 720 730 730 740 740 750 750 760 760 700 700 117+50.00 710 710 720 720 730 730 740 740 750 750 760 760 700 700 118+00.00 X-22 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W C /L P R O P . T R A C K # 5 (T O B E S H I F T E D ) C / L E X I S T . S I D I NG T R A C K EXIST GROUND LINE 7 0 7 .4 9 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E S H I F T E D ) C / L E X I S T . S I D I N G T R A C K C /L P R O P . T R A C K # 5 EXIST GROUND LINE 7 0 7 . 4 6 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 710 710 720 720 730 730 740 740 750 750 760 760 700 700 118+50.00 700 700 710 710 720 720 730 730 740 740 750 750 760 760 119+00.00 X-23 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E S H I F T E D ) C / L E X I S T . S I D I NG T R A C K 40:1 EXIST GROUND LINE 7 0 7 .5 1 WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER CRASHWALL TO FACE OF 15.03' NEW 15" RCP. & REPLACE WITH LOCATION. REMOVE INLET - APPROX. EXISTING DRAINAGE 705.41 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E S H I F T E D ) C / L E X I S T . S I D I NG T R A C K 40:1 EXIST GROUND LINE 7 0 7 . 5 5 WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER CRASHWALL TO FACE OF 16.79' 705.25 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 740 740 750 750 690 690 119+50.00 710 710 720 720 730 730 740 740 750 750 700 700 120+00.00 X-24 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E S H I F T E D ) C / L E X I S T . S I D I NG T R A C K 40:1 EXIST GROUND LINE 7 0 7 .5 9 WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER CRASHWALL TO FACE OF 18.49' 705.17 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 2:1 2: 1 2:1 (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K 40:140:1 EXIST GROUND LINE 7 0 7 . 6 3 IN THIS AREA TYPICAL. AREA. GRADE TO DRAIN IS LOCATED IN THIS DRAINAGE STRUCTURE CONFIRM THAT A CONTRACTOR TO EXISTING LOW AREA. 704.50 706.622: 1 704.00 709.13 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 710 710 720 720 730 730 740 740 750 750 700 700 120+50.00 710 710 720 720 730 730 740 740 750 750 700 700 121+00.00 X-25 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 2:1 2: 1 2:1 (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K 40:140:1 EXIST GROUND LINE 7 0 7 .5 6 706.17 704.44 2: 1 704.50 716.46 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K 40:140:1 EXIST GROUND LINE 7 0 7 .2 7 2:1 2: 1 WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER 706.00 704.14 705.73 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 740 740 690 690 121+50.00 710 710 720 720 730 730 700 700 122+00.00 700 700 710 710 720 720 730 730 122+50.00 X-26 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 2: 1 2:1 REQUESTED SURVEY ADDITIONAL (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K 40:1 40:1 EXIST GROUND LINE 7 0 6 .7 6 2: 1 2:1 WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER WALL SHOWN) TO REMAIN (CRASH EXIST BRIDGE PIER CRASHWALL TO FACE OF 12.80' 706.33 703.63703.03 705.19 C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 40:140:1 2: 1 1:1 (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 6 P R O P . F E N C E EXIST GROUND LINE 7 0 6 .14 2 WALL NORTH SIDE OF CRASH INCOMING DITCH FROM ROAD ACCESS PROP. 10' 708.16 702.45 2:1 703.48 2: 1 710.44 50:1 50:1 705.58 C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 1:140:1 40:1 2: 1 2:1 (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K EXIST GROUND LINE 7 0 5 .5 1 720.00 710.45 ROAD ACCESS PROP. 10' 708.28 701.88 2:1 50:1 702.54 2: 1 709.91 50:1 704.96 7 0 5 .5 1 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 690 690 123+00.00 700 700 710 710 720 720 730 730 690 690 123+50.00 700 700 710 710 720 720 730 730 690 690 123+71.54 X-27 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C / L E X I S T . M A I N T R A C K P R O P . F E N C E P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 40:1 2: 1 2:1 (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / WE X I S T . R / W (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K EXIST GROUND LINE 7 0 4 .8 91:1ROAD ACCESS PROP. 10' 701.30 708.20 2:1 701.61 2: 1 709.63 50:1 704.34 C / L E X I S T . M A I N T R A C K P R O P . F E N C E P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 2:1 WALL PROP. RET. (B Y O T H E R S ) C /L F U T U R E T R A C K E X I S T . N S R R / W C /L P R O P . T R A C K # 7 E X I S T . R / W 2: 1 PROP. ACCESS ROAD EXIST GROUND LINE 40:1 7 0 4 .2 61:1 708.44 700.73 2:1 700.68 2: 1 710.10 50:150:1 703.71 40:1 PROP. ACCESS ROAD P R O P . F E N C E C /L P R O P . T R A C K # 7 C /L P R O P . T R A C K # 6 2:1 2: 1 E X I S T . N S R R / W 40:1 C /L P R O P . T R A C K # 5 WALL PROP. RET. P R O P . R O W EXIST GROUND LINE8:1 WALKWAY PROP. 7 0 3 .9 91:1 708.79 700.48700.32 7 0 4 .8 9 7 0 4 .2 6 7 0 3 .9 8 7 0 3 . 9 8 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 690 690 124+00.00 700 700 710 710 720 720 730 730 690 690124+50.00 700 700 710 710 720 720 730 730 690 690125+00.00 X-28 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 40:1 40:1 PROP. ACCESS ROAD WALL PROP. RET. E X I S T . N S R R / W (B Y O T H E R S ) C /L F U T U R E T R A C K 2:1 2: 1 P R O P . R O W EXIST GROUND LINE 7 0 3 .6 4 BUILDING FOR PROP. PROP. FFE 1:150:1 708.99 700.15 711.21 700.35 4 2:1 703.35 P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 40:1 1:1 2:1 E X I S T . N S R R / W 40:1 P R O P . F E N C E 8:1 WALL PROP. RET. P R O P . R O W EXIST GROUND LINE 7 0 3 .0 2 BUILDING FOR PROP. PROP. FFE 2: 1 50:11:1 50 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 710.71 699.58 2:1 699.96 2: 1 713.62 50:1 698.76 702.26 P R O P . F E N C E C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 40:1 1:1 2:1 WALL PROP. RET. E X I S T . N S R R / W 40:1 P R O P . F E N C EPRO P . R O W EXIST GROUND LINE 7 0 2 . 3 9 C /L P R O P . T R A C K # 5 BUILDING FOR PROP. PROP. FFE 2: 1 8:150:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 714.10 699.24 2:150:1 698.14699.76 716.43 701.64 7 0 3 .6 3 7 0 3 .6 3 7 0 3 .0 1 7 0 3 .0 1 7 0 2 .4 2 7 0 2 . 4 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 690 690125+07.33 700 700 710 710 720 720 730 730 690 690125+50.00 700 700 710 710 720 720 730 730 690 690126+00.00 X-29 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS 2:11:1C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 4' DIAMETER PRECAST MANHOLE NCDOT STD. 840.52 EXISTING 18" RCP APPROX. INV ELEV. = 715.28 P R O P . F E N C EPRO P . F E N C E E X I S T . N S R R / W EXIST GROUND LINE 7 0 2 . 3 0 C /L P R O P . T R A C K # 5 8:1 2: 1 50:1 4' DIAMETER PRECAST MANHOLE NCDOT STD. 840.52 717.80MATCH EXISTING GRADE 718.20 +/- ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 714.00 699.19 701.84 700.83 700.71 PROPOSED 18" RCP 699.68 2: 1 2:150:1 698.04 CIVIL SITE PLANS BUILDING GENERAL WITH PROPOSED COORDINATE PROP. RET. WALLGENERAL CIVIL SITE PLANS PROPOSED BUILDING COORDINATE WITH FROM OFFICE BUILDING PROPOSED 18" RCP 701.55 P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:140:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINEC /L P R O P . T R A C K # 5 7 0 1 . 7 7 8:1 2: 1 50:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 712.17 698.91 2:1 50:1 697.51 699.25 2: 1 717.12 701.02 P R O P . F E N C E P R O P . F E N C E 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINEC /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 7 0 1 .14 8:1 2: 1 50:1 8 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 710.56 698.58 2:1 698.73 2: 1 716.57 696.89 50:1 CONCRETE CATCH BASIN NCDOT STD. 840.02 52 700.39 7 0 2 .3 7 7 0 2 .3 9 7 0 1 .8 3 7 0 1 .8 4 7 0 1 .2 3 7 0 1 .2 7 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 690 690126+50.00 700 700 710 710 720 720 730 730 740 740 690 690 127+00.00 700 700 710 710 720 720 730 730 690 690 127+50.00 X-30 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINE 7 0 0 .5 2 8:1 2: 1 50:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 709.89 698.24 710.00 708.00 710.71 2:150:1 698.22 696.33 699.77 P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINE 6 9 9 .9 0 2: 1 8:150:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 709.03 697.91 707.00 702.00 2:1 2: 1 697.71 50:1 709.92 BERM PROP. 5' 695.64 699.14 P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINE 6 9 9 .3 2 8:1 2: 1 50:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10'705.60 697.58 702.00 707.00 2:150:1 695.07 2: 1 697.19 708.65 BERM PROP. 5' 698.57 7 0 0 . 6 4 7 0 0 .7 0 7 0 0 .0 5 7 0 0 .13 6 9 9 .4 5 6 9 9 .5 3 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 700 700 710 710 720 720 690 690128+00.00 700 700 710 710 720 720 690 690 128+50.00 690 690 700 700 710 710 720 720 129+00.00 690 690 700 700 710 710 720 720 129+50.00 X-31 5 10 P-2918F -TRK5- STAGE 2CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 2:1 EXIST GROUND LINE 6 9 8 .9 0 8:1 2: 1 50:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 702.45 697.24 707.00 702.00 2:150:1 694.64 696.68 2: 1 707.88 BERM PROP. 5' CONCRETE CATCH BASIN NCDOT STD. 840.02 12 54 698.15 P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 1:140:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K 2:1 EXIST GROUND LINE 6 9 8 .6 3 8:12: 1 702.00 50:1 707.00 DROP INLET TRAFFIC BEARING GRATED NCDOT STD. 840.36 705.00 ELEV. 702.00 1" ORIFICE @ ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 701.00 696.91 696.26 696.16 696.16 2: 1 707.00 2:150:1 HDPE - TYPICAL & PERFORATED 6" SMOOTH WALL BERM PROP. 5' 694.49 PROPOSED 18" RCP 697.88 C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . F E N C E EXIST GROUND LINE 6 9 8 . 5 2 8:1 2: 1 50:1 56 TYPICAL CLEANOUT PIPE HDPE HEADER 6" SMOOTH WALL ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 700.39 693.83 1.5:12:12: 1 695.65 702.10 50:1 694.34 696.58 697.97 P R O P . F E N C E C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 1:1 40:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K C /L P R O P . T R A C K # 7 1:1 EXIST GROUND LINE 6 9 8 .5 2 45:1 BY OTHERS OIL-WATER SEPARATOR @ 1.0% TYPICAL DISCHARGE PIPE 6" DIP DRIP PAN HDPE - TYPICAL & PERFORATED 6" SMOOTH WALL ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 1.5:1 8:1 2: 1 693.68 2:1 695.18 2: 1 702.06 50:1 694.19 696.69 697.84 6 9 8 .9 9 6 9 9 .0 5 6 9 8 .6 9 6 9 8 .7 2 6 9 8 . 5 4 6 9 8 .5 5 6 9 8 .5 2 6 9 8 .5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 680 680129+85.69 690 690 700 700 710 710 720 720 680 680 130+00.00 690 690 700 700 710 710 720 720 730 730 130+50.00 X-32 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS C /L P R O P . T R A C K # 7 40:1 C /L P R O P . T R A C K # 6 1:140:1 EXISTING 48" RCP (TO REMAIN) P R O P . F E N C E E X I S T . N S R R / W EXIST GROUND LINE 6 9 8 .5 2C /L P R O P . T R A C K # 5 41.5:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 699.99 1.5:1 8:1 2: 1 693.57 2:1 50:12: 1 694.85 701.91 694.08 EXISTING 48" RCP (TO REMAIN) - APPROX. LOCATION 696.76 697.75 C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . F E N C E C /L P R O P . T R A C K # 7 EXIST GROUND LINE 6 9 8 .5 2 8:140:1 16 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 1.5:1 2: 1 693.53 701.92 2:1 694.72 2: 1 50:1 CONCRETE CATCH BASIN NCDOT STD. 840.02 694.04 696.79 697.72 P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K EXIST GROUND LINE 6 9 8 .5 2 8:135:1 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 1.5:1 2: 1 693.38694.25 2: 1 701.99 2:1 50:1 693.89 696.90 697.84 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 730 730 680 680 131+00.00 690 690 700 700 710 710 720 720 730 730 131+50.00 700 700 710 710 720 720 730 730 690 690 132+00.00 X-33 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 1:140:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE 6 9 8 . 5 2 8:1 30:1 18 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 1.5:1 2: 1 693.23693.79 2: 1 703.15 2:1 50:1 693.74 58 697.01 697.97 P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE 6 9 8 . 5 2 8:1 25:1 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 706.29 1.5:1 2: 1 693.08 SIDEWALK PROP. 10' 2:1 50:1 693.32 2: 1 50:1 693.59 697.11 697.84 C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 1:1 E X I S T . N S R R / W 40:140:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . F E N C E P R O P . R O W EXIST GROUND LINE 6 9 8 . 5 2 8:1 20:1 22 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 1.5:1 692.93 50:150:1 2:1 692.86 2: 1 706.72 CONCRETE CATCH BASIN NCDOT STD. 840.02 693.44 697.22 697.72 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 700 700 710 710 720 720 730 730 690 690 132+50.00 700 700 710 710 720 720 730 730 690 690 133+00.00 690 690 700 700 710 710 720 720 730 730 133+50.00 X-34 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W EXIST GROUND LINE 6 9 8 . 5 2 8:115:1 62 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 692.78 1.5:1 2:1 50:1 2: 1 692.39 707.64 693.29 697.05 697.84 P R O P . F E N C E C / L E X I S T . M A I N T R A C K 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C KPRO P . R O W EXIST GROUND LINE 6 9 8 . 5 2 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 5 8:1 20:1 24 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 706.09 712.75 1.5:1 2: 1 692.63 2:1 50:1 2: 1 691.93 693.14 697.00 697.97 P R O P . F E N C E C / L E X I S T . M A I N T R A C K 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W P R O P . R O W EXIST GROUND LINE 6 9 8 . 5 2 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 5 8:1 25:1 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10'704.42 712.63 1.5:1 2: 1 692.48 2:1 2: 1 691.46 50:1 692.99 696.90 697.84 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120120 120120 130130 130130 140140 140140 150150 150150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 730 730 740 680 680 134+00.00 690 690 700 700 710 710 720 720 680 134+50.00 690 690 700 700 710 710 720 720 730 730 680 680 135+00.00 X-35 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W P R O P . R O W EXIST GROUND LINE 6 9 8 . 5 2 8:1 30:1 28 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 704.84 712.73 1.5:1 2: 1 692.33 50:1 2:1 2: 1 691.00 CONCRETE CATCH BASIN NCDOT STD. 840.02 692.84 64 696.79 697.72 P R O P . F E N C E C / L E X I S T . M A I N T R A C K C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W P R O P . R O W EXIST GROUND LINE 6 9 8 . 5 2 8:1 35:1 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 711.93 1.5:1 2: 1 692.18 2: 1 690.53 2:1 50:1 692.69 696.68 697.84 P R O P . F E N C E C / L E X I S T . M A I N T R A C K 40:1 1:1 E X I S T . N S R R / W 40:1 C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 5 (B Y O T H E R S ) C /L F U T U R E T R A C K 695.35 P R O P . R O W P R O P . R O W EXIST GROUND LINE 6 9 8 . 5 2 702.19 8:140:1 30 68 ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 702.32 710.86 1.5:1 2: 1 692.03 50:1 2:1 690.06 2: 1 692.54 696.57 697.97 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 9090 9090 100100 100100 110110 110110 120 120 130 130 140 140 150 150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 680 680 135+50.00 690 690 700 700 710 710 720 720 680 680 136+00.00 690 690 700 700 710 710 720 720 730 730 680 680 136+50.00 X-36 5 10 P-2918F -TRK5- STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS 120130140150 120130140150 P R O P . F E N C E 40:1 E X I S T . N S R R / W 40:1 C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 1:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W P R O P . R O W EXIST GROUND LINE 6 9 8 . 5 2 8:145:1 BY OTHERS OIL-WATER SEPARATOR @ 1.0% TYPICAL DISCHARGE PIPE 6" DIP DRIP PAN ROAD ACCESS PROP. 10' ROAD ACCESS TEMP. 10' 702.74 710.11 1.5:1 2: 1 691.71 50:1 2:1 2: 1 689.60 692.39 696.47 697.84 P R O P . F E N C E 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K P R O P . R O W P R O P . R O W EXIST GROUND LINE C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 6 9 8 . 5 2 8:150:1 34 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 706.80 701.60 691.39 2:1 2: 1 689.13 50:1 1.5:1 1.5:1 CONCRETE CATCH BASIN NCDOT STD. 840.02 692.24 70 697.72 P R O P . F E N C E 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K 2:1 2: 1 688.67 P R O P . R O WPRO P . R O W EXIST GROUND LINE (PHASE 1A) EXIST GROUND LINE C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 8:1 2: 1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 50:1 2:1 707.06 692.09 690.91 698.65 700.27 697.84 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 90 90 100 100 110 110 120 120 130 130 140 140 150 150 690 690 700 700 710 710 720 720 680 680 136+73.83 690 690 700 700 710 710 680 680 137+00.00 690 690 700 700 710 710 720 720 680 680 137+50.00 X-37 5 10 P-2918F -TRK5- 160 170 160 170 STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 700 710 140150160170 720 M A T C H L I N E A - A S E E S H E E T INSET A M A T C H L I N E A - A S E E I N S E T 90100110120130 90100110120130 130 120 1:1 1:1 40:1 40:1 2:1 690.32 688.45 2: 1 PROPOSED 36" RCP690.45 688.45 P R O P . F E N C E C /L P R O P . T R A C K # 6 E X I S T . N S R R / W P R O P . R O W EXIST GROUND LINE (PHASE 1A) EXIST GROUND LINE C /L P R O P . T R A C K # 5 8:1 2: 1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 50:1 2:1 707.63 692.02 698.39 700.08 697.90 P R O P . F E N C E C / L E X I S T . M A I N T R A C K 1:1 40:1 1:1 E X I S T . N S R R / W 40:1 (B Y O T H E R S ) C /L F U T U R E T R A C K 688.88 2:1 2: 1 688.20 P R O P . R O W EXIST GROUND LINE (PHASE 1A) EXIST GROUND LINE C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 8:1 2: 136 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 50:1 2:1 708.30 691.94 697.00 699.54697.97 P R O P . F E N C E 1:1 40:1 40:1 E X I S T . N S R R / W (B Y O T H E R S ) C /L F U T U R E T R A C K 2: 1 687.65 2:1 2: 1 687.74 P R O P . R O W EXIST GROUND LINE (PHASE 1A) EXIST GROUND LINE C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 8:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 50:1 2:1 710.35 691.79 698.1250:1 697.84 EXISTING 36" RCP APPROX. INV ELEV. = 701.83 P R O P . R O W 6' DIAMETER PRECAST MANHOLE NCDOT STD. 840.52 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 6 9 8 .5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 90 90 100 100 110 110 120 120 130 130 140 140 150 150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 680 680 138+00.00 690 690 700 700 710 710 720 720 680 680 138+50.00 690 690 700 700 710 710 720 720 680 680 139+00.00 X-38 5 10 P-2918F -TRK5- 160 160 170 170 STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS 90100110120130 90100110120130 P R O P . F E N C E 1:140:1 1:140:1 E X I S T . N S R R / W (B Y O T H E R S ) C /L F U T U R E T R A C K 2: 1 686.00 2:1 2: 1 687.27 P R O P . R O W EXIST GROUND LINE (PHASE 1A) EXIST GROUND LINE C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 5 8:1 40 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 50:1 2:1 712.47 CONCRETE CATCH BASIN NCDOT STD. 840.02 691.64 74 693.03 50:1697.72 P R O P . F E N C E 1:140:1 1:1 E X I S T . N S R R / W 40:1 2: 1 685.00 2:1 2: 1 686.81 P R O P . R O W EXIST GROUND LINE (PHASE 1A) EXIST GROUND LINE C /L P R O P . T R A C K # 5 C /L P R O P . T R A C K # 6 8:1 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 50:1 2:1 691.49 689.00 690.00 50:1 697.84 P R O P . F E N C E 1:140:1 40:1 E X I S T . N S R R / W (R E M OV E ) E X I S T . F E N C E 684.00 2:1 1:1 686.34 2: 1 P R O P . R O W EXIST GROUND LINE (PHASE 1A) EXIST GROUND LINE C /L P R O P . T R A C K # 5 8:1 2: 1 42 ROAD ACCESS PROP. 10' ROAD ACCESS PROP. 10' 50:1 2:1 712.96 691.34 688.62 690.00 50:1 50:1 697.95 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 90 90 100 100 110 110 120 120 130 130 140 140 150 150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 680 680 139+50.00 690 690 700 700 710 710 720 720 680 680 139+65.20 690 690 700 700 710 710 720 720 680 680 140+00.00 X-39 5 10 P-2918F -TRK5- 160 170 180 160 170 180 STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS 90100110120 90100110120 P R O P . F E N C E 1:140:1 40:1 E X I S T . N S R R / W (R E M OV E ) E X I S T . B U I L D I NG 684.00 2:1 2: 1 685.88 P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . B U I L D I N G (PHASE 1A) EXIST GROUND LINE C /L P R O P . T R A C K # 5 2: 1 8:11:1ROAD ACCESS PROP. 10' 50:1 2:1 ROAD ACCESS PROP. 711.52 691.19 50:1 50:1 688.23 689.66 697.74 POND CONTROL VOLUME @ 690.00 TOP OF RISER @ 690.00 POND OVERFLOW @ 691.00 684.35 PROPOSED 36" RCP 684.00 1:140:1 685.73 2: 1 40:1 2: 1 2:1 684.00 P R O P . F E N C E E X I S T . N S R R / W P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . B U I L D I N G(R E M OV E ) E X I S T . B U I L D I NG (PHASE 1A) EXIST GROUND LINE C /L P R O P . T R A C K # 5 50:1 2:1 ROAD ACCESS PROP. 711.15 BASIN CONCRETE CATCH NCDOT STD. 840.02 691.15 46 76 50:1 50:1 687.85 689.75 697.73 P R O P . F E N C E C /L P R O P . T R A C K # 5 1:140:1 40:1 2: 1 685.41 E X I S T . N S R R / W (R E M OV E ) E X I S T . B U I L D I N G P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . B U I L D I NG (PHASE 1A) EXIST GROUND LINE691.00 2: 1 50:1 2:1 ROAD ACCESS PROP. 709.63 50:1 50:1 687.42 697.86 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 00 00 1010 1010 2020 2020 3030 3030 4040 4040 5050 5050 6060 6060 7070 7070 8080 8080 90 90 100 100 110 110 120 120 130 130 140 140 150 150 3 / 4 / 2 0 1 6 I : \ P r o j e c t s \ 4 0 1 5 1 5 6 \ 4 0 1 5 1 5 6 _ 0 0 0 1 \ 9 0 _ C A D M o d e l s a n d S h e e t s \ 0 4 _ C K _ T r a c k _ R a i l \ 4 0 1 5 1 5 6 _ T R K _ X P L _ 1 B . d g n b l i n d j e 8 / 2 3 / 9 9 PROJ. REFERENCE NO.SHEET NO.0 690 690 700 700 710 710 720 720 680 680140+18.00 690 690 700 700 710 710 720 720 680 680 140+50.00 690 690 700 700 710 710 720 720 680 680140+72.48 X-40 5 10 P-2918F -TRK5- 160 170 180 160 170 180 STAGE 2 CONSTRUCTION (BY OTHERS) TO BE REMOVED PRIOR TO EXISTING CONTAMINATED SOILS 90100110120 90100110120 1:1 40:1 684.81 (2) 6X6 RCBC 685.04 40:1 2: 1 2: 1 685.04 P R O P . F E N C E E X I S T . N S R R / W P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . B U I L D I N G (PHASE 1A) EXIST GROUND LINE C /L P R O P . T R A C K # 5 684.00 50:1 2:1 ROAD ACCESS PROP. 50:1 50:1 689.00 697.94 P R O P . F E N C E P R O P . F E N C E C /L P R O P . T R A C K # 5 40:1 E X I S T . N S R R / W (R E M OV E ) E X I S T . B U I L D I N G (R E M OV E ) E X I S T . B U I L D I N G (R E M OV E ) E X I S T . F E N C E 40:1 2: 1 691.20 P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . F E N C E (PHASE 1A) EXIST GROUND LINE 2: 1 683.00 50:1 2:1 ROAD ACCESS PROP. 706.42 48 50:1 50:1 686.81 688.72 696.46 P R O P . F E N C E P R O P . F E N C E P R O P . F E N C E P R O P . F E N C E 40:1 40:1 E X I S T . N S R R / W P R O P . R O W P R O P . R O W EXIST GROUND LINE (R E M OV E ) E X I S T . B U I L D I NG (R E M OV E ) E X I S T . B U I L D I NG (R E M A I N ) E X I S T . B U I L D I NG 683.00 C /L P R O P . T R A C K # 5 (R E M OV E ) E X I S T . F E N C E (PHASE 1A) EXIST GROUND LINE 50:1 ROAD ACCESS PROP. 699.26 694.14 50:150:1 686.62 689.00 695.16 6 9 8 . 5 2 6 9 8 . 5 2 6 9 8 . 5 2 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 INDEX OF SHEETSINDEX OF SHEETS 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL WATER & SANITARY SEWER SYSTEM IMPROVEMENTS LOCOMOTIVE & RAILCAR MAINTENANCE FACILITY VICINITY MAP NTS LOCATION MAP NTS TIP NO.: P-2918F SHEET NO. U1 COVER SHEET SHEET NO. U2 PERMITS APPLICATION SANITARY SEWER RELOCATION FACILITY IMPROVEMENTS WATER / LOCOMOTIVE & RAILCAR MAINTENANCE 2 LOCOMOTIVE & RAILCAR MAINTENANCE FACILITY IMPROVEMENTS WATER / SANITARY SEWER RELOCATION A CITY OF CHARLOTTE DEPARTMENT DATE SURVEY COMPLETED: TOPO NO: PHONE: INSIDE CHARLOTTE: ( ) YES ( ) NO: DATE SURVEY COMPLETED: CONTRACTOR: DEVELOPER: INSPECTOR: ADDRESS: PHONE: DESIGN COMPANY: DATE DESIGN COMPLETED: SURVEY COMPANY: PLANS PREPARED BY: SURVEYED BY: ADDRESS: ADDRESS: PHONE: TOPO NO: PHONE: INSIDE CHARLOTTE: ( ) YES ( ) NO: CONTRACTOR: DEVELOPER: INSPECTOR: ADDRESS: PHONE: DESIGN COMPANY: DATE DESIGN COMPLETED: SURVEY COMPANY: PLANS PREPARED BY: SURVEYED BY: ADDRESS: ADDRESS: PHONE: 2/29/2016 900 WEST TRADE ST., SUITE 715, CHARLOTTE, NC 28202 (704) 372-1885 - (704) 509-9918 DEWBERRY & DAVIS, INC. DEWBERRY & DAVIS, INC. 6135 LAKEVIEW ROAD, SUITE 400 - - - - - - CHARLOTTE, NORTH CAROLINA SUMMARY OF SEWER MAINS & MANHOLES SIZE PROJECT NAME: TOTAL NO. LOTS SERVED: DATE AS BUILT: DATE OF ACTIVATION: TOTAL NO. OF MANHOLES: JOB NO: SIZE LENGTH BY: N.C.P.E. LENGTH APPROVAL SEAL C H A LO T T E TERWWW RH SIZE PROJECT NAME: TOTAL NO. LOTS SERVED: DATE AS BUILT: DATE OF ACTIVATION: JOB NO: SIZE LENGTH BY: N.C.P.E. LENGTH APPROVAL SEAL SUMMARY OF WATER MAINS & FIRE HYDRANTS TOTAL NO. OF FIRE HYDRANTS: 3/4/2016 10:39:31 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_COVER.dgn WATER STANDARD SPECIFICATIONS. ACCORDANCE WITH CHARLOTTE CONSTRUCTION SHALL BE IN STV ENGINEERS, INC. STV ENGINEERS, INC. SHEET NO. U3 54" WATER MAIN PLAN AND PROFILE SHEET NO. U12 WATER AND SEWER ABANDONMENT PLAN XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. SHEET NO. U4 W. PALMER ST SEWER PLAN AND PROFILE SHEET NO. U5 W. PALMER ST WATER PLAN AND PROFILE SHEET NO. U6 W. PALMER ST WATER PLAN AND PROFILE SHEET NO. U7 PENMAN ST SEWER PLAN AND PROFILE SHEET NO. U8 PROP. 6-INCH SEWER PLAN AND PROFILE SHEET NO. U9 PROP. 6-INCH WATER PLAN AND PROFILE SHEET NO. U10 PROP. 8-INCH SEWER PLAN AND PROFILE SHEET NO. U11 WATER AND SEWER ABANDONMENT PLAN NOT THE ITEM WAS SPECIFIED. CERTIFICATION FROM THE MANUFACTURER REGARDLESS OF WHETHER OR DRAWING SUBMITTAL SHALL BE ACCOMPANIED WITH A LETTER OF PROJECT SHALL MEET "BUY AMERICA" REQUIREMENTS. EACH SHOP 14. ALL PRODUCTS, BUILDING MATERIALS, AND EQUIPMENT ON THIS A COPY ON THE JOB SITE AT ALL TIMES. REQUIRED TO OWN A COPY OF THE DESIGN MANUAL AND SHALL KEEP 13. ALL CONTRACTORS WORKING ON CHARLOTTE WATER PROJECTS ARE SEWER LATERALS SHALL HAVE MIN. 1% SLOPE. SUBJECT TO RELOCATION DUE TO FIELD CONDITIONS. ALL 4" SANITARY 12. SANITARY SEWER LATERAL LOCATIONS ARE APPROXIMATE AND ARE AND BYPASS PUMPING. PROJECT MANUAL REGARDING OUTAGE, TEMPORARY WATER SERVICE, SHALL FOLLOW CHARLOTTE WATER PROCEDURES AS OUTLINED IN THE CONSTRUCTION. IF THIS IS NOT POSSIBLE, THEN THE CONTRACTOR 11. WATER AND SEWER LINES ARE TO REMAIN ACTIVE DURING WATER AND/OR SANITARY SEWER WORK. 10. CHARLOTTE WATER SHALL BE NOTIFIED PRIOR TO THE BEGINNING OF MINIMUM SEPARATION CANNOT BE MAINTAINED. OF THE CROSSING, AND ALL ALONG THE LENGTH OF MAINS WHERE IRON PIPE SHALL BE USED FOR BOTH MAINS TO 10 FEET EITHER SIDE THE ABOVE MINIMUM SEPARATIONS CANNOT BE MAINTAINED, DUCTILE OVER SEWER MAINS. WHEN WATER MAINS ARE BELOW SEWER MAINS OR VERTICAL SEPARATION SHALL BE MAINTAINED BETWEEN WATER MAINS 9. MINIMUM PIPE SEPARATION: 10 FEET HORIZONTAL SEPARATION OR 18" AND/OR PIPE INSTALLATION. UNDERGROUND UTILITIES ENCOUNTERED DURING TRENCH EXCAVATION 8. THE CONTRACTOR SHALL SUPPORT AND PROTECT ANY EXISTING OF ALL UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. INFORMATION. THE CONTRACTOR SHALL VERIFY LOCATION AND DEPTH THE ACCURACY OF LOCATION, SIZE, DEPTH, OR COMPLETENESS OF THE CONSULTANT AND/OR AGENT SHALL NOT BE HELD RESPONSIBLE FOR DURING CONSTRUCTION OPERATIONS. NCDOT RAIL DIVISION, DESIGN USE OF THE CONTRACTOR IN PROVIDING PROTECTION FOR THE UTILITIES 7. THE LOCATION OF EXISTING UTILITIES SHOWN ON THE PLANS IS FOR THE AGREED UPON BETWEEN THE CONTRACTOR AND THE PROPERTY OWNER. 6. IF ADDITIONAL WORK SPACE IS NEEDED, AN ENCROACHMENT IS TO BE DIRECTED. 5. THE CONTRACTOR SHALL USE EROSION CONTROL MEASURES, AS GAS COMPANY AT 704-525-5585 AND INFORM THEM. GAS MAIN, THEN THE CONTRACTOR SHALL CALL PIEDMONT NATURAL WITHIN 12" IN ANY DIRECTION (VERTICALLY OR HORIZONTALLY) FROM A 4. IF THE PROPOSED WATER AND/OR SANITARY SEWER MAIN IS INSTALLED C.D.O.T. WORK AREA TRAFFIC CONTROL HANDBOOK (WATCH). IN THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES AND/OR 3. ANY NECESSARY LANE CLOSURES SHALL FOLLOW GUIDELINES OUTLINED STANDARDS PART 1926, SUBPART P, AS AMENDED TO DATE. 2. ALL SHORING SHALL BE IN ACCORDANCE WITH OSHA TRENCHING STANDARD SPECIFICATIONS. 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHARLOTTE WATER GENERAL NOTES: SHEET NO. U13 THRUST WALL DETAIL - TIE RODS 7030600038-16-011 7030600017-16-521 54" 6" 12" 8" 12 N/A N/A 4" PVC S/L CO 700.94 GV GV LS REM FH P FH PFH LS SSCO TGVPWM PRPZ SHEET U7 S HE E T U4 W. Su m m it Av S. Clarkson St W. Su m m it Av Win o n a St Co m m erce St Q ui n ce y StLincoln St Pen man St D un bar St S Mint St S Graham St W Carson Bv John Belk FyI-277 S Clarkson St S H E E T U 3 SHEET U8 S HE E T U6 SHEET U10 SHEET U11 SHEET U12 S. Graham St W. Blan d St StreetW. PalmerSHEET U9 SHEET U5 Merriman Av I-77 I-277 PROJECT AREA DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/20163/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 N / A N / A PERMITS APPLICATION CHARLOTTE, NORTH CAROLINA C H A LO T T E TERWWW RH 1885372704 NONE N/A 100 - (704) 372-1885 DATE LOCOMOTIVE & RAILCAR MAINTENANCE FACILITY UNAVAILABLE 8 INCH/12 INCH 900 WEST TRADE STREET, SUITE 715 CHARLOTTE, NORTH CAROLINA 28202-1144 XIAOLIN DENG, PE XIAOLIN DENG, PE 900 WEST TRADE STREET, SUITE 715 CHARLOTTE, NORTH CAROLINA 28202-1144 LOCOMOTIVE & RAILCAR MAINTENANCE FACILITY U2 STV ENGINEERS, INC. STV ENGINEERS, INC. N / A IRWIN APPLICATION FOR PERMIT FOR WATER MAIN EXTENSION AND UPON COMPLETION OF CONSTRUCTION INDICATES THAT CONSTRUCTION WAS COMPLETED IN ACCORDANCE STATE OF NORTH CAROLINA SHALL SUBMIT A STATEMENT REFLECTING THAT ADEQUATE OBSERVATIONS DURING OF CLTWater OR ITS AUTHORIZED REPRESENTATIVE. A PROFESSIONAL ENGINEER LICENSED TO PRACTICE IN THE AND SPECIFICATIONS APPROVED BY CLTWater WILL BE MADE WITHOUT THE WRITTEN CONSENT AND APPROVAL 15A NCAC 18C.1801. THE APPLICANT AGREES THAT NO SIGNIFICANT CHANGE OR DEVIATION FROM THE PLANS CLTWater HAS BEEN GRANTED AUTHORITY TO ISSUE PERMITS FOR EXTENSION OF WATER MAINS PURSUANT TO NORTH CAROLINA GENERAL STATUTES, AND SUCH OTHER STATUTES AS RELATED TO PUBLIC WATER SYSTEMS. THIS APPLICATION IS MADE UNDER AND IN FULL ACCORD WITH THE PROVISIONS OF CHAPTER 130A-317 OF THE APPROVED: WITH APPROVED PLANS AND SPECIFICATIONS. PERMIT NO. DESIGNED BY: FIRM: PROJECT NAME: PROJECT DESCRIPTION: CLTWater PROJECT NO.: CHARLOTTE, NORTH CAROLINA 28216 CHARLOTTE WATER 5100 BROOKSHIRE BLVD. PHONE: ADDRESS: ENGINEER: HAS BEEN REVIEWED BY ME AND IS ACCURATE AND COMPLETE TO THE PREPARED IN ACCORDANCE WITH THE APPLICABLE REGULATIONS. ALTHOUGH CERTAIN PORTIONS OF THIS SUBMITTAL SIGNATURE AND SEAL SIGNIFIES THAT I HAVE REVIEWED THIS MATERIAL AND HAVE JUDGED IT TO BE CONSISTENT WITH BEST OF MY KNOWLEDGE. I FURTHER ATTEST THAT TO THE BEST OF MY KNOWLEDGE THE PROPOSED DESIGN HAS BEEN PACKAGE MAY HAVE BEEN DEVELOPED BY OTHER PROFESSIONALS, INCLUSION OF THESE MATERIALS UNDER MY I, , ATTEST THAT THIS APPLICATION FOR NORTH CAROLINA PROFESSIONAL ENGINEER'S SEAL, SIGNATURE, AND DATE: COMPLETE NAME AND ADDRESS OF ENGINEERING DESIGN FIRM: PIPE DIAMETER OF SEWERS IMMEDIATELY DOWNSTREAM PERMIT NO. FOR SEWERS IMMEDIATELY DOWNSTREAM HAS ENGINEER DETERMINED THAT DOWNSTREAM SEWERS ARE CAPABLE TO HANDLE THIS FLOW? YES NO IF A PRETREATMENT PERMIT IS REQUIRED, HAS ONE BEEN ISSUED? YES NO IF WASTEWATER IS NON-DOMESTIC, DESCRIBE LEVEL OF PRETREATMENT: JOSEPH C WILSON, P.E., CHIEF ENGINEER CLTWater PERMIT NO. ISSUED PERMIT APPROVED BY: PLANT FLOW ALLOCATION RECORDED BY: THE PROPOSED DESIGN. PROFESSIONAL ENGINEER'S CERTIFICATION: TELEPHONE - - PROJECT? YES NO SCHOOL INDUSTRIAL LIST ANY PARAMETER AND ITS CONCENTRATION THAT WILL BE GREATER THAN NORMAL DOMESTIC LEVELS: ORIGIN OF WASTEWATER SUBDIVISION COMMERCIAL McALPINE CR. (NC0024970) IRWIN CR. (NC0024945) McDOWELL CR. (NC0036277) SUGAR CR. (NC0024937) MALLARD CR. (NC0030210) ROCKY CR. (NC0036269) WASTEWATER TREATMENT PLANT RECEIVING WASTEWATER: 135 GAL/DAY/MULTI-FAMILY UNIT X UNITS OR IS BASED ON : PROJECT TYPE: NEW CONSTRUCTION RELOCATION MODIFICATION OF PERMIT NO. VOLUME OF WASTEWATER GENERATED BY THIS PROJECT: GALLONS PER DAY BASED ON 190 GAL/DAY/SINGLE FAMILY HOUSEHOLD X HOUSEHOLDS OR PROJECT NAME OTHER CLTWater PROJECT NO.: CREEK BASIN HAS ENGINEER DETERMINED THAT NC DEM AND CLTWater MINIMUM DESIGN STANDARDS ARE MET BY THIS APPLICATION FOR NON-DISCHARGE PERMIT CHARLOTTE WATER GRAVITY SEWER MAIN EXTENSION APARTMENTS/CONDO'S OTHER JOSEPH C WILSON, P.E., CHIEF ENGINEER 7030600017-16-521 7030600038-16-011 - - RELOCATION 8" AND 12" SANITARY SEWER APPROX. 385 LF 54" WATER MAIN APPROX. 1400 LF 6" WATER MAIN 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANSDO NOT USE FOR R/W ACQUISITIONPRELIMINARY PLANS MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/4/2016 10:39:34 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_PERMIT.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 U3 690 695 700 705 710 715 720 10+00 11+00 12+00 13+00 685 14+00 0 20 40 SCALE 1" = 20' 60 80 1" = 20' PLAN AND PROFILE 54" WATER MAIN1" = 4' 1" = 20' 720 715 710 705 700 695 690 685 WHETHER OR NOT THE ITEM WAS SPECIFIED. CERTIFICATION FROM THE MANUFACTURER REGARDLESS OF DRAWING SUBMITTAL SHALL BE ACCOMPANIED WITH A LETTER OF PROJECT SHALL MEET "BUY AMERICA" REQUIREMENTS. EACH SHOP 3. ALL PRODUCTS, BUILDING MATERIALS, AND EQUIPMENT ON THIS RESTRICTION. DELIVERY TO THE SITE IN ORDER TO MEET THE TIME OF YEAR COMPLETE THE CONNECTIONS AND ORDER ALL MATERIALS FOR CONNECTION AND VERIFY ANY OTHER MEASUREMENTS REQUIRED TO VERIFY THE LOCATION OF THE EXIST. PIPE JOINTS FOR 2. THE CONTRACTOR SHALL EXPOSE THE EXIST. 54" WATER MAIN AND COMPLETED WITHIN 30 CONSECUTIVE CALENDAR DAYS. ALLOWED BETWEEN DECEMBER 26TH AND MARCH 15TH AND SERVICE OF THE EXIST. 54" PCCP WATER LINE SHOULD BE ONLY 1. ACCORDING TO CHARLOTTE WATER, INTERRUPTION TO WATER NOTES: 705 7 1 0 710 715 72 0 720 7 2 5 725 7 3 0 730 735 R A I L R O AD S T R E ET (N E V E R O P E N E D ) 1 8 .5 0 0 0 + 3 6 .80 1 0 2 .99 + 07 .8 0 86 .64 + 66 .3 3 2 0 .2 6 + 13 .3 9 2 6 .72 + 77 .5 6 19 .5 0 + 0 0 .0 0 C C 10+00 11+00 1+00 12+00 13+00 P R O P . D I T C H LINE EASEMENT EXIST. WATER 11.25° BEND PROP. 54" DI RJ STA. 10+20.00 PC250 WATER LINE OF 54" RJ DIP PROP. 385± LF N S R E X I S T . R /W P R O P . T R A C K # 5 N S R E X I S T . R /W P R O P . D I T C H P R O P. S S M H- 3 S T A. 1 + 5 5. 9 1 STEEL CASING BY OPEN CUT PROP. 60± LF OF 78" CASING BY JACK AND BORE PROP. 106± LF OF 78" STEEL AND VERTICAL ALIGNMENT) TO ACHIEVE HORIZONTAL 45° BEND (ROTATE BEND PROP. 54" DI RJ STA. 13+40.03 AND VERTICAL ALIGNMENT) TO ACHIEVE HORIZONTAL 45° BEND (ROTATE BEND PROP. 54" DI RJ STA. 13+74.41 OF FENCE IF NEEDED AND REPLACE SECTION CONTRACTOR TO REMOVE RECIEVING PIT 12'x20' BORE PIT 12'x40' S E E S H E E T U 4 F O R D E T AI L S P R O P. 8 " S A N I T A R Y S E W E R S56°59 '36"E P R O P. S S M H- 2 S T A. 0 + 3 9. 8 6 8 " DI P S A N I T A R Y S E W E R P R O P. 1 1 6 ± L F O F (CLTWater JOB No. 636046) TO REMAIN IN SERVICE EXIST. 54" WATER LINE F I L L L I N E P R O P . C U T / 2 2. 5° B E N D P R O P. 6 " DI R J S T A. 1 1 + 5 1. 1 9 TIE INTO EXIST. 54" WATER LINE PROP. 54" LONG PATTERN SLEEVE PROP. 54" PCCP x DIP ADAPTER PROP. THRUST WALL (SEE SHEET U13) STA. 10+00.00 E X I S T . T R A C K E X I S T . T R A C K TIE INTO EXIST. 54" WATER LINE PROP. 54" LONG PATTERN SLEEVE PROP. 54" PCCP x DIP ADAPTER PROP. THRUST WALL (SEE SHEET U13) STA. 13+84.41 CASING BY OPEN CUT PROP. 104± LF OF 78" STEEL (CLTWater JOB No. 636046) REMAIN IN SERVICE EXIST. 54" WATER LINE TO WALL RETAINING EXIST. EXIST. FENCE 1 5 5 ° 5 4' 5 8 " FOR DETAILS SEE SHEET 3-E DEMOLISHED. WALL TO BE EXIST. RETAINING SECTION OF THE E X I S T . F E N C E E X I S T . N S R R / W C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K (T O B E R E M OV E D ) C / L E X I S T . S I D I NG T R A C K C /L P R O P . T R A C K # 6 E X I S T . F E N C E E X I S T . N S R R / W LINE TO REMAIN EXIST. 54" PCCP WATER LINE TO REMAIN EXIST. 54" PCCP WATER PROP. GRADE EXIST. GRADE MIN. 12" CLEARANCE PROP. 54" LONG PATTERN SLEEVE PROP. 54" PCCP x DIP ADAPTER PROP. THRUST WALL STA. 10+00.00 PROP. 54" LONG PATTERN SLEEVE PROP. 54" PCCP x DIP ADAPTER PROP. THRUST WALL STA. 13+84.41 PROP. 54" RJ DIP WATER MAIN PRESSURE CLASS 250 COVER MIN. 4.5' (T=1.000") PROP 270± LF OF 78" STEEL CASING LINER PLATES CASING TO BE ABANDONED EXIST. 54" PCCP WATER LINE WITH 96" STEEL C /L P R O P . T R A C K # 5 STA. 13+35.00 S T A . 1 0 + 0 0 . 0 0 S T A . 1 3 + 8 4 . 4 1 STA. 10+65.48 UNDERDRAIN PROP. 6" DEMOLISHED SECTION TO BE EXIST. RETAINING WALL 702.622 :1 40:1 701.84 2: 1 50:1 2 :1 1 : 1 FROM TOP OF RAIL MIN. 6' CLEARANCE B O R E P I T P I T R E C E I V I N G FROM TOP OF RAIL 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANSDO NOT USE FOR R/W ACQUISITIONPRELIMINARY PLANS MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/4/2016 10:39:40 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_sheet_03.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 U4 LINE A 0 20 40 SCALE 1" = 20' 60 80 1" = 20' 1" = 20' 1" = 4' 690 695 700 705 710 715 720 685 685 690 695 700 705 710 715 720 5+004+003+002+001+000+00 PLAN AND PROFILE W. PALMER ST. SEWER OR NOT THE ITEM WAS SPECIFIED. THE MANUFACTURER REGARDLESS OF WHETHER WITH A LETTER OF CERTIFICATION FROM DRAWING SUBMITTAL SHALL BE ACCOMPANIED "BUY AMERICA" REQUIREMENTS. EACH SHOP EQUIPMENT ON THIS PROJECT SHALL MEET 1. ALL PRODUCTS, BUILDING MATERIALS, AND NOTES: 4 " P V C S /L C O 700.94 7 0 5 7 0 5 7 0 5 7 0 5 71 0 715 7 1 5 S S S M A LL HA R D W OO D S SM H R IM =718.31 C L INV =710.09 R IM =713.98 8 " IN V IN =7 06.22 8 " INV OU T =700.63 SM H RIM=701.98 CL INV=694.10 SMH GV WV GV S T E S T E S 18 . 5 0 0 0 + 2 9 . 2 4 T E S T E S 24.7-FT 18" RCP 715.28 699.68 700.83 700.71 701.84 696.8 9 11+00 12+00 0 + 0 0 1+00 2+00 16+00 SSCO 13+00 14+00 15+00 3+00 4+00 5+00 TO REMAIN IN SERVICE EXIST. 8" SANITARY SEWER W PALMER ST P R O P . T R A C K # 5 P R O P . T R A C K # 6 P R O P . T R A C K # 7 N S R E X I S T . R / W PROP. SSMH-4 STA. 5+22.52 SANITARY SEWER OF 8" DIP PROP. 367± LF BY OPEN CUT 18" STEEL CASING PROP. 193±LF OF BY JACK AND BORE 18" STEEL CASING PROP. 91± LF OF BY OPEN CUT 18" STEEL CASING PROP. 59±LF OF PROP. SSMH-3 STA. 1+55.91 P R O P . D I T C H P R O P . C U T / F I LL L I N E N S R E X I S T . R / W P R O P . D I T C H P R O P . C U T / F I L L L I N E OF FENCE IF NEEDED AND REPLACE SECTION CONTRACTOR TO REMOVE BORE PIT 10'x40' RECIEVING PIT 10'x15' FOR DETAILS SEE SHEETS U5-U6 PROP. 6" WATER LINE N 3 5 ° 5 8 ' 1 1 " E S56°59'36"E S32°54'34"E 92°57'47" PROP. SSMH-2 STA. 0+39.86 8" DIP SANITARY SEWER PROP. 116± LF OF 8" DIP SANITARY SEWER PROP. 40± LF OF 173°27'45" E X I S T . T R A C K E X I S T . T R A C K STUBOUT AND COUPLING TIE INTO EXIST. PIPE WITH PROP. SSMH-1 REPLACE EXIST. MANHOLE STA. 0+00.00 (LINE A) FENCE EXIST. PIPE DRAINAGE EXIST. 155°54'58" OF FENCE IF NEEDED AND REPLACE SECTION CONTRACTOR TO REMOVE THE EXIST. SEWER LATERAL CONTRACTOR TO FIELD LOCATE PROP. CLEANOUT SEWER 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANSDO NOT USE FOR R/W ACQUISITIONPRELIMINARY PLANS MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/4/2016 10:39:43 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_sheet_04.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL SERVICE REMAIN IN SEWER TO SANITARY EXIST. 8" EXIST. 8" SANITARY SEWER TO BE ABANDONED (REMOVE SEGMENT IF NEEDED) C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 E X I S T . N S R R / W E X I S T . F E N C E E X I S T . F E N C E E X I S T . N S R R / W C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K & TYPE A FRAME SSMH-1 W/ TYPE 1 COVER PROP. 4' DIA. MANHOLE STA. 0+00.00 REPLACE EXIST. MANHOLE & TYPE A FRAME SSMH-3 W/ TYPE 1 COVER PROP. 4' DIA. MANHOLE STA. 1+55.91 & TYPE A FRAME SSMH-4 W/ TYPE 1 COVER PROP. 5' DIA. MANHOLE STA. 5+22.52 & TYPE A FRAME SSMH-2 W/ TYPE 1 COVER PROP. 4' DIA. MANHOLE STA. 0+39.86 L PROP. F IN = 694.13L EXIST. F OUT = 694.10 116.05 LF @ 0.60% PRESSURE CLASS 350 PROP. 8" DIP SANITARY SEWER 39.86 LF @ 0.60% PRESSURE CLASS 350 PROP. 8" DIP SANITARY SEWER PROP. F OUT = 694.37 PROP. F IN = 694.40L L PROP. F OUT = 695.10 PROP. F IN = 695.13L L PROP. F OUT = 697.33L STA. 1+65.91 STA. 5+08.62 (T=0.312") 18" STEEL CASING PROP. 343± LF OF EXIST. GRADE PROP. GRADE 366.61 LF @ 0.60% PRESSURE CLASS 350 PROP. 8" RJ DIP SANITARY SEWER C /L P R O P . T R A C K # 5 PROP. WATER MAIN TO BE REMOVED EXIST. DRAINAGE PIPE CLEARANCE MIN. 12" UNDERDRAIN PROP. 6" UNDERDRAIN PROP. 6" B O R E P I T P I T R E C E I V I N G FROM TOP OF RAIL 2 :1 1 : 1 699.28 2: 1 50:1 2 :1 40:1 699.68 FROM TOP OF RAIL MIN. 6' CLEARANCE DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 U5 0 20 40 SCALE 1" = 20' 60 80 1" = 20' 1" = 20' 1" = 4' M A T C H L I N E W T -6 D I P S T A . 1 3 + 5 0 . 0 0 S E E S H E E T U 6 M A T C H L I N E W T -6 D I P S T A . 1 3 + 5 0 . 0 0 S E E S H E E T U 6 690 695 700 705 710 715 720 10+00 11+00 12+00 13+00 685 720 715 710 705 700 695 690 685 PLAN AND PROFILE, SHEET 1 OF 2 W. PALMER ST. WATER NOT THE ITEM WAS SPECIFIED. FROM THE MANUFACTURER REGARDLESS OF WHETHER OR BE ACCOMPANIED WITH A LETTER OF CERTIFICATION REQUIREMENTS. EACH SHOP DRAWING SUBMITTAL SHALL ON THIS PROJECT SHALL MEET "BUY AMERICA" 1. ALL PRODUCTS, BUILDING MATERIALS, AND EQUIPMENT NOTES:7 0 5 7 0 57 0 5 7 0 5 S S M A LL HA R D W OO D S RIM=701.98 CL INV=694.10 SMH WEST PALMER STREET CLOSED 08/28/1989 RES. BK. 25, PG. 348 DEED BK. 6161, PG. 812 10+00 11+00 12+00 0 + 0 0 1+00 2+00 13+00 3+00 TO REMAIN IN SERVICE EXIST. 6" WATER LINE N S R E X I S T . R / W TIE INTO EXIST. 6" WATER LINE (CLTWater STD. DETAIL #DD) PROP. REINFORCED CROSS BLOCKING PROP. 6" LONG PATTERN SLEEVE STA. 10+00.00 6" RJ DIP WATER LINE OF FENCE IF NEEDED AND REPLACE SECTION CONTRACTOR TO REMOVE BORE PIT 10'x40' SEE SHEET U4 FOR DETAILS PROP. 8" SANITARY SEWER BY JACK AND BORE 16" STEEL CASING (CLTWater JOB No. 636046 ) TO REMAIN IN SERVICE EXIST. 54" WATER LINE 45° BEND PROP. 6" DI RJ STA. 10+72.55 22.5° BEND PROP. 6" DI RJ STA. 11+51.19 45° BEND PROP. 6" DI RJ STA. 10+05.00 BY OPEN CUT 16" STEEL CASING TIE INTO EXIST. 54" WATER LINE PROP. 54" LONG PATTERN SLEEVE PROP. 54" PCCP x DIP ADAPTER PROP. THRUST WALL (SEE SHEET U13) STA. 10+00.00 E X I S T . T R A C K E X I S T . T R A C K 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANSDO NOT USE FOR R/W ACQUISITIONPRELIMINARY PLANS MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/4/2016 10:39:46 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_sheet_05.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL (APPROX. DEPTH) TO REMAIN WATER LINE EXIST. 6" DIP E X I S T . N S R R / W E X I S T . F E N C E C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K E X I S T . F E N C E EXIST. GRADE (T=0.281") 16" STEEL CASING PROP 142± LF (335± LF TOTAL) STA. 12+07.97 S T A . 1 0 + 0 0 . 0 0 PRESSURE CLASS 350 6" RJ DIP WATER LINE PROP. 8" SEWER (VERTICAL) 11.25° BEND PROP. 6" DI RJ STA. 11+86.40 (VERTICAL) 11.25° BEND PROP. 6" DI RJ STA. 12+02.97 MIN. 12" CLEARANCE FROM TOP OF RAIL MIN. 6' CLEARANCE COVER MIN. 3' B O R E P I T DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 U6 0 20 40 SCALE 1" = 20' 60 80 1" = 20' 1" = 20' 1" = 4' 690 695 700 705 710 715 720 690 695 700 705 710 715 720 725 725 M A T C H L I N E W T - 6 D I P S T A . 1 3 + 5 0 .0 0 S E E S H E E T U 5 M A T C H L I N E W T -6 D I P S T A . 1 3 + 5 0 . 0 0 S E E S H E E T U 5 14+00 15+00 16+00 17+00 PLAN AND PROFILE, SHEET 2 OF 2 W. PALMER ST. WATER NOT THE ITEM WAS SPECIFIED. FROM THE MANUFACTURER REGARDLESS OF WHETHER OR BE ACCOMPANIED WITH A LETTER OF CERTIFICATION REQUIREMENTS. EACH SHOP DRAWING SUBMITTAL SHALL ON THIS PROJECT SHALL MEET "BUY AMERICA" 1. ALL PRODUCTS, BUILDING MATERIALS, AND EQUIPMENT NOTES: 4 " P V C S /L C O 700.94 71 0 715 7 1 5 720 725 S SM H R IM =718.31 C L INV =7 10.09 R IM =7 13.98 8" IN V IN =7 06.22 8 " IN V OU T =700.6 3 SM H G R E A S E TR A P SM H R IM=7 26.26 8" IN =719.47 8" IN =719.37 8 " OU T =719.3 0 GV WV GV S G M G V GV D WVWV W M W V D G V W V S W M W V W V W M T E S T E S 18 . 5 0 0 0 + 2 9 . 2 4 6 4 . 5 3 + 3 9 . 4 5 T E S T E S 24.7-FT 18" RCP 715.28 699.68 700.83 700.71 701.84 696.8 9 GV GV L S REM FH P F H L S 16+00 SSCO 14+00 15+00 17+00 3+00 4+00 5+00 TO REMAIN IN SERVICE EXIST. 6" WATER LINE W PALMER ST P R O P . T R A C K # 5 P R O P . T R A C K # 6 P R O P . T R A C K # 7 P R O P . D I T C H P R O P . C U T / F I LL L I N E N S R E X I S T . R / W P R O P . D I T C H P R O P . C U T / F I L L L I N E (DIRECT BURY) PROP. RJ GV & VALVE BOX STA. 17+27.79 (5' RT) PROP. 6" x 6" DI RJ TEE STA. 17+27.79 (DIRECT BURY) PROP. RJ GV & VALVE BOX STA. 17+17.78 TO REMAIN IN SERVICE EXIST. 6" WATER LINE 6" RJ DIP WATER LINE W PALMER ST BY OPEN CUT 16" STEEL CASING PROP. 183± LF OF RECIEVING PIT 10'x15' SEE SHEET U4 FOR DETAILS PROP. 8" SANITARY SEWER SEE SHEET U4 FOR DETAILS PROP. 8" SANITARY SEWER PROP. FIRE HYDRANT W/STORZ FITTING PROP 15' LF 6" RJ DIP PROP. 6" RJ GV & VALVE BOX (DIRECT BURY) PROP. 6" x 6" DI RJ TEE STA. 17+04.79 11.25° BEND PROP. 6" DI RJ STA. 15+48.13 FENCE EXIST. PIPE DRAINAGE EXIST. OF FENCE IF NEEDED AND REPLACE SECTION CONTRACTOR TO REMOVE PROP. 6" LINE STOP PROP. 6" LINE STOP PATTERN SLEEVE 2 - PROP. 6" LONG 6" RJ DIP WATER LINE 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANSDO NOT USE FOR R/W ACQUISITIONPRELIMINARY PLANS MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/4/2016 10:39:49 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_sheet_06.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 E X I S T . F E N C E APPROX. DEPTH EXIST. TELEPHONE E X I S T . N S R R / W E X I S T . F E N C E E X I S T . F E N C E TO BE ABANDONED EXIST. SEWER EXIST. GRADE PROP. GRADE (APPROX. DEPTH) WATER LINE EXIST. 6" DIP (T=0.281") 16" STEEL CASING PROP 193± LF (335± LF TOTAL) 6" RJ DIP WATER LINE PRESSURE CLASS 350 COVER MIN. 3' STA. 15+43.13 S T A . 1 7 + 2 7 . 7 9 C /L P R O P . T R A C K # 5 TO BE REMOVED EXIST. DRAINAGE PIPE (VERTICAL) 45° BEND PROP. 6" DI RJ STA. 15+71.43 (VERTICAL) 45° BEND PROP. 6" DI RJ STA. 15+53.13 MIN. 24" CLEARANCE FROM TOP OF RAIL MIN. 6' CLEARANCE UNDERDRAIN PROP. 6" UNDERDRAIN PROP. 6" P I T R E C E I V I N G 1 : 1 699.58 2 :1 50:1 699.19 2: 1 40:12 :1 DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 U7 LINE B 0 20 40 SCALE 1" = 20' 60 80 1" = 20' SEWER PLAN AND PROFILE PENMAN STREET 1" = 20' 1" = 4' 690 695 700 705 710 685 685 690 695 700 705 710 0+00 1+00 2+00 3+00 675 680 675 680 690 695 700 705 710 10+00 11+00 685 675 680 695 700 705 710 685 690 680 675 LINE B-1 NOT THE ITEM WAS SPECIFIED. FROM THE MANUFACTURER REGARDLESS OF WHETHER OR BE ACCOMPANIED WITH A LETTER OF CERTIFICATION REQUIREMENTS. EACH SHOP DRAWING SUBMITTAL SHALL ON THIS PROJECT SHALL MEET "BUY AMERICA" 1. ALL PRODUCTS, BUILDING MATERIALS, AND EQUIPMENT NOTES: 6 9 0 6 9 0 6 9 5 69 5 69 5 700 700 7 0 0 700 7 0 0 7 0 5 S 2 X EL M S M H R IM =695 .45 8 " IN =686 .05 8" O U T =681.97 S M H R IM =699 .78 12" IN =688 .74 12 " OU T =688 .63 S WM R A I L R OA D S T R EE T C L O S E D 0 5 / 2 6 / 19 9 8 R E S . B K . 3 5 , P G . 6 3 D EE D B K . 9 8 08 , P G . 80 5 T E S T E S 2 0 1 .16 + 3 0 .0 7 T E S T E S 693 .83 696.27 696.16 34.0-FT 18" RCP 694.0 4 6 94.04 1 97-LF 18" RCP 0 + 0 0 1+00 0 + 0 0 2+00 PENMAN STREET TO REMAIN IN SERVICE EXIST. 12" SANITARY SEWER P R O P . C U T / F I LL L I N E P R O P . T R A C K # 6 P R O P . T R A C K #7 P R O P . T R A C K # 5 S37°2'14"E BY OPEN CUT 24" STEEL CASING PROP. 150± LF OF SANITARY SEWER OF 12" DIP PROP. 257± LF SANITARY SEWER OF 12" DIP PROP. 15± LF PROP. SSMH-6 STA. 0+15.00 (LINE B) BY JACK AND BORE 24" STEEL CASING PIPE PROP. 94± LF OF PROP. SSMH-7 STA. 0+00.00 (LINE B-1) STA. 2+72.00 (LINE B) 8" DIP SANITARY SEWER PROP. 53± LF OF PROP. SSMH-7A STA. 0+13.49 (LINE B-1) PROP. SSMH-7B STA. 0+66.49 (LINE B-1) N S R E X I S T . R / W N S R E X I S T . R / W P R O P . C U T /F I LL L I N E P R O P . D I T C H P R O P . D I T C H TO REMAIN IN SERVICE EXIST. 12" SANITARY SEWER STUBOUT AND COUPLING TIE INTO EXIST. PIPE WITH PROP. SSMH-8 STA. 2+93.91 (LINE B) STUBOUT AND COUPLING TIE INTO EXIST. PIPE WITH PROP. SSMH-5 REPLACE EXIST. MANHOLE (LINE B) STA. 0+00.00 8" DIP SANITARY SEWER PROP. 14± LF OF 12" DIP SANITARY SEWER PROP. 22± LF OF PIT RECEIVING 10'x15' BORE PIT 10'x40' D R A I NA G E P I P E P R O P . 18 " E X I S T . T R A C K E X I S T . T R A C K EXIST. FENCE E X I S T . T R A C K PIPE DRAINAGE EXIST. 147°6'41"117°44'10" 120°0'0" 123°39'45" 96°44'39" D R A I NA G E P I P E P R O P . 18 " 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANSDO NOT USE FOR R/W ACQUISITIONPRELIMINARY PLANS MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/4/2016 10:39:53 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_sheet_07.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL PROP. GRADE C /L P R O P . T R A C K # 6 C /L P R O P . T R A C K # 7 E X I S T . N S R R / W C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K C / L E X I S T . M A I N T R A C K E X I S T . F E N C E & TYPE B FRAME SSMH-6 W/ TYPE 1 COVER PROP. 4' DIA. MANHOLE STA. 0+15.00 PROP. F IN = 682.17L L L L LPROP. F OUT = 683.70 PROP. F IN = 684.03 (LINE B-1) PROP. F IN = 692.16 (LINE B) 15.00 LF @ 0.47% PRESSURE CLASS 350 PROP. 12" DIP SANITARY SEWER LPROP. F OUT = 692.76 LEXIST. F OUT = 681.97 LEXIST. F IN = 692.96 SERVICE REMAIN IN SEWER TO SANITARY EXIST. 12" IN SERVICE TO REMAIN SANITARY SEWER EXIST. 12" STA. 2+64.00 (T=0.406") 24" STEEL CASING PROP. 244± LF OF STA. 0+20.00 TO BE ABANDONEDEXIST. 12" SANITARY SEWER EXIST. GRADE PROP. F OUT = 682.24 PROP. F IN = 682.44 L L 21.91 LF @ 2.74% SANITARY SEWER PROP. 12" DIP REPLACE EXIST. MANHOLE & TYPE B FRAME SSMH-5 W/ TYPE 1 COVER PROP. 4' DIA. MANHOLE STA. 0+00.00 & TYPE A FRAME SSMH-8 W/ TYPE 1 COVER PROP. 4' DIA. MANHOLE STA. 2+93.91 OUTSIDE DROP & TYPE A FRAME SSMH-7 W/ TYPE 1 COVER PROP. 5' DIA. MANHOLE STA. 0+00.00 (LINE B-1) STA. 2+72.00 C /L P R O P . T R A C K # 5 257.00 LF @ 0.49% PRESSURE CLASS 350 SANITARY SEWER PROP. 12" RJ DIP PROP. 18" RCP PROP. 18" RCP UNDERDRAIN PROP. 6" UNDERDRAIN PROP. 6" P I T R E C E I V I N G FROM TOP OF RAIL MIN. 6' CLEARANCE FROM TOP OF RAIL MIN. 6' CLEARANCE COVER MIN. 3' COVER MIN. 3' 1. 5: 1 45:1 695.31 2 :150:1 40:1 1 : 1 B O R E P I T PROP. GRADE APPROX. DEPTH EXIST. WATER E X I S T . F E N C E & TYPE A FRAME SSMH-7B W/ TYPE 1 COVER PROP. 4' DIA. MANHOLE STA. 0+66.59 & TYPE A FRAME SSMH-7A W/ TYPE 1 COVER PROP. 4' DIA. MANHOLE STA. 0+13.49 & TYPE A FRAME SSMH-7 W/ TYPE 1 COVER PROP. 5' DIA. MANHOLE STA. 2+72.00 (LINE B) STA. 0+00.00 PROP. F OUT = 684.11 PROP. F IN = 684.31L L COVER MIN. 3' EXIST. GRADE COVER MIN. 3' LPROP. F OUT = 684.63 PROP. F OUT = 683.70 PROP. F IN = 684.02 (LINE B-1) PROP. F IN = 692.16 (LINE B)L L L 13.49 LF @ 0.67% PRESSURE CLASS 350 SANITARY SEWER PROP. 8" DIP 53.10 LF @ 0.60% SEWER PRESSURE CLASS 350 PROP. 8" DIP SANITARY TO REMAIN EXIST. 48" RCP PROP. 18" RCP DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 U8 0 20 40 SCALE 1" = 20' 60 80 1" = 20' 1" = 20' 1" = 4' M A T C H L I N E W T - 6 S T A . 1 3 + 0 0 . 0 0 S E E S H E E T U 9 M A T C H L I N E W T -6 S T A . 1 3 + 0 0 .0 0 S E E S H E E T U 9 690 695 700 705 710 715 685 685 690 695 700 705 710 715 10+00 11+00 12+00 13+00 680 680 PLAN AND PROFILE, SHEET 1 OF 2 PROP. 6-INCH WATER LINE NOT THE ITEM WAS SPECIFIED. FROM THE MANUFACTURER REGARDLESS OF WHETHER OR BE ACCOMPANIED WITH A LETTER OF CERTIFICATION REQUIREMENTS. EACH SHOP DRAWING SUBMITTAL SHALL ON THIS PROJECT SHALL MEET "BUY AMERICA" 1. ALL PRODUCTS, BUILDING MATERIALS, AND EQUIPMENT NOTES: 69 5 695 7 0 0 705 7 1 0 71 0 2 0 ' M B S L ( T Y P I C A L ) W M W V W V W V W M S 65.48 +72.48 59.94 +53.73 48.31 +56.70 32.35 +22.60 10.73 +28.15 9.46 +72.48 C 685 686 687 688 689 690 691 692 684 10+00 11+00 TGV PWM PRPZ 12+00 W S U M M I T A V E IN SERVICE TO REMAIN WATER MAIN EXIST. 12" PROP. CUT/FILL LINE PROP. TRACK #5 IN SERVICE TO REMAIN WATER MAIN EXIST. 12" SLEEVE AND VALVE FULL BODY TAPPING PROP. 12"x6" STA. 10+00.00 DRAINAGE POND PROP. STORM OF 6" DIP WATER LINE PROP. DITCH (CLTWater STD. DETAIL #N) ASSEMBLY AND VAULT PROP. 6" METER DISCHARGE PER CHARLOTTE WATER REQUIREMENT HEATED ENCLOSURE TO INCLUDE DRAIN PORT FOR INSTALLED ABOVE GROUND WITHIN INSULATED AND PROP. 6" REDUCED PRESSURE PRINCIPLE ASSEMBLY CULVERT DUAL BOX PROP. 6'x6' PIPE DRAINAGE PROP. 45° BEND PROP. 6" DI RJ STA. 10+98.86 HORIZONTAL AND VERTICAL ALIGNMENT) (ROTATE BEND TO ACHIEVE BOTH 22.5° BEND PROP. 6" DI RJ STA. 10+51.21 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANSDO NOT USE FOR R/W ACQUISITIONPRELIMINARY PLANS MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/4/2016 10:39:56 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_sheet_08.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL PROP. 6'x6' DUAL BOX CULVERT S T A . 1 0 + 0 0 . 0 0 S T A . 1 1 + 3 5 . 0 0 6" DIP WATER LINE PRESSURE CLASS 350 EXIST. GRADE PROP. GRADE MIN. 3' COVER (APPROX. DEPTH) TO REMAIN WATER LINE EXIST. 12" DIP (VERTICAL) 11.25° BEND PROP. 6" DI RJ STA. 10+71.51 E X I S T . F E N C E UNDERDRAIN PROP. 6" UNDERDRAIN PROP. 6" APPROX. DEPTH EXIST. TELEPHONE PROP. 36" RCP DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 0 20 40 SCALE 1" = 20' 60 80 1" = 20' 1" = 20' 1" = 4' M A T C H L I N E W T -6 S T A . 1 3 + 0 0 .0 0 S E E S H E E T U 8 M A T C H L I N E W T - 6 S T A . 1 3 + 0 0 . 0 0 S E E S H E E T U 8 690 695 700 705 710 685 685 690 695 700 705 710 680680 13+00 14+00 15+00 16+00 U9 PLAN AND PROFILE, SHEET 2 OF 2 PROP. 6-INCH WATER LINE 715 715 NOT THE ITEM WAS SPECIFIED. FROM THE MANUFACTURER REGARDLESS OF WHETHER OR BE ACCOMPANIED WITH A LETTER OF CERTIFICATION REQUIREMENTS. EACH SHOP DRAWING SUBMITTAL SHALL ON THIS PROJECT SHALL MEET "BUY AMERICA" 1. ALL PRODUCTS, BUILDING MATERIALS, AND EQUIPMENT NOTES: 70 5 705 7 1 0 710 D I SMH RIM = 706. 81 8" IN= 698.99 8" OU T= 696.5 5 S 1 2 9 0 , P A G E 4 0 0 D E E D B O O K C C 690 686 687 688 692.03692.03 691 692 689 692.84692.84692.24692.24 P F H 14+00 15+00 16+00 PROP. TRACK #6 PROP. TRACK #5 PLATFORM PROP. STATION NSR EXIST. R/W PROP. DITCH PROP. CUT/FILL LINE DRAINAGE POND PROP. STORM OF 6" DIP WATER LINE W/ STORZ FITTING PROP. FIRE HYDRANT & VALVE BOX (DIRECT BURY) PROP. 6" RJ GV STA. 16+25.10 STORM PIPE EXIST. PIPE PROP. STORM 90° BEND PROP. 6" DI RJ STA. 16+15.75 TO BE ABANDONED SEWER EASEMENT EXIST. SANITARY TO BE ABANDONED SEWER EASEMENT EXIST. SANITARY 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANSDO NOT USE FOR R/W ACQUISITIONPRELIMINARY PLANS MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/4/2016 10:40:00 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_sheet_09.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL TO BE ABANDONED EXIST. SEWER PROP. 18" RCP S T A . 1 6 + 2 5 . 1 0 S T A . 1 4 + 9 8 . 1 0 MIN. 3' COVER EXIST. GRADE PROP. GRADE 6" DIP WATER LINE PRESSURE CLASS 350 E X I S T . F E N C E UNDERDRAIN PROP. 6" TO BE REMOVED STORM PIPE EXIST. 36" MIN. 12" CLEARANCE MIN. 12" CLEARANCE DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 LINE C 0 20 40 SCALE 1" = 20' 60 80 1" = 20' 1" = 20' 1" = 4' U10 PLAN AND PROFILE PROP. 8-INCH SEWER 690 695 700 705 710 715 720 685 685 690 695 700 705 710 715 720 0+00 1+00 2+00 3+00 4+00 NOT THE ITEM WAS SPECIFIED. FROM THE MANUFACTURER REGARDLESS OF WHETHER OR BE ACCOMPANIED WITH A LETTER OF CERTIFICATION REQUIREMENTS. EACH SHOP DRAWING SUBMITTAL SHALL ON THIS PROJECT SHALL MEET "BUY AMERICA" 1. ALL PRODUCTS, BUILDING MATERIALS, AND EQUIPMENT NOTES: 7 0 5 7 1 0 710 7 1 0 7 1 0 7 1 5 7 1 5 7 1 5 7 1 5 C B SMH RIM = 7 12. 97 8" IN = 704.06 RIM = 7 0 3.6 3 SMH 8" IN = 6 95.59 8" IN = 69 5.54 8" OU T = 695.40 SMH RIM = 708.45 8" IN = 701.03 8" IN=70 1.15 8" OU T=700.23 D W V S G V W M W V S S SM H RIM =711.59 S 313.76 +80.61 326.62 +55.21 376.36 +89.96 424.09 +89.33 0+00 2+00 1+00 3+00 4+00 W S U M M I T A V E TO REMAIN IN SERVICE EXIST. 8" SANITARY SEWER TO REMAIN IN SERVICE EXIST. 8" SANITARY SEWER TO REMAIN IN SERVICE EXIST. 8" SANITARY SEWER CONNECT TO EXIST. MANHOLE STA. 0+00.00 TO REMAIN IN SERVICE EXIST. 8" SANITARY SEWER N64°26'34"EN68°38'22"E SANITARY SEWER OF 8" DIP PROP. 133± LF PROP. SSMH-9 STA. 1+33.16 SANITARY SEWER OF 8" DIP PROP. 271± LF W I N O N A S T EXIST. FENCE EXIST. FENCE 102°53'31"175°48'13" 95°0'0" STUBOUT AND COUPLING TIE INTO EXIST. PIPE W/ PROP. SSMH-10 STA. 4+03.78 APPROX. DEPTH EXIST. WATER APPROX. DEPTH EXIST. WATER APPROX. DEPTH EXIST. WATER APPROX. DEPTH EXIST. TELEPHONE & TYPE A FRAME SSMH-9 W/ TYPE 1 COVER PROP. 4' DIA. MANHOLE STA. 1+33.16 PROP. F OUT = 697.50 PROP. F IN = 697.70L L LLPROP. F OUT = 701.55 LLPROP. F IN = 695.60 SERVICE REMAIN IN SEWER TO SANITARY EXIST. 8" IN SERVICE TO REMAIN SANITARY SEWER EXIST. 8" LEXIST. F IN = 701.75 L EXIST. MANHOLE STA. 0+00.00 L LEXIST. F OUT = 695.40 EXIST. F IN = 695.59 EXIST. F IN = 695.54 EXIST. GRADE 270.62 LF @ 1.42%PRESSURE CLASS 350PROP. 8" DIP SANITARY SEWER 133.16 LF @ 1.43% PRESSURE CLASS 350 PROP. 8" DIP SANITARY SEWER APPROX. DEPTH EXIST. WATER EXIST. RETAINING WALL & TYPE A FRAME SSMH-10 W/ TYPE 1 COVER PROP. 4' DIA. MANHOLE STA. 4+03.78 COVER MIN. 3' 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANSDO NOT USE FOR R/W ACQUISITIONPRELIMINARY PLANS MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/4/2016 10:40:03 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_sheet_10.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 WATER AND SEWER ABANDONMENT PLAN 1" = 40' N/A N/A 0 40 80 SCALE 1" = 40' 120 160 U11 MATCHLINE ABANDONMENT PLAN SEE SHEET U12 NOT THE ITEM WAS SPECIFIED. FROM THE MANUFACTURER REGARDLESS OF WHETHER OR BE ACCOMPANIED WITH A LETTER OF CERTIFICATION REQUIREMENTS. EACH SHOP DRAWING SUBMITTAL SHALL ON THIS PROJECT SHALL MEET "BUY AMERICA" 1. ALL PRODUCTS, BUILDING MATERIALS, AND EQUIPMENT NOTES: 685 69 0 69 0 69 0 6 9 0 6 9 0 69 0 6 9 0 69 5 695 69 5 695 69 5 69 5 700 7 00 7 0 0 700 7 0 5 7 0 5 705 705 705 70 5 710 710 7 1 0 710 710 710 710 710 7 1 0 71 5 715 715 715 715 7 1 5 715 715 7 1 5 715 720 D I CB CB CB CB CB CB CB GA S L I N E L O C A T I ON P E R F I EL D M A R K I NG S R A I L R O A D S P U R L I N E R A I L R OA D SP U R L I N E RAILROAD SPURLINE R A I L R O AD M A I N L I N E T R A C K 1 R A I L R OA D M A I N L I N E T R A C K 2 20 ' MBSL (TYPICAL) S B U I L D I N G (T Y P I C A L ) D I CB SMH R IM=687 .47 8 " OU T =68 2.37 8 " V C P S MH RIM=7 12.9 7 8" IN =704 .06 8 " IN =704.06 8" OU T=7 03 .8 6 C B CB CB D I D I D I D I SMH R IM=68 8.82 8" INV =681.80 8" INV=682.39 8" INV OUT =681.61 SMH R IM=68 9.03 8" IN=683 .8 7 8 " OU T =68 3.60 SMH RIM=702 .59 8 " IN =69 5.79 8" OU T=6 95.62 R IM=70 3.63 SMH 8" IN=695.59 8" IN=695 .54 8 " OUT =69 5.40 SMH R IM=706 .81 8 " IN =69 8.99 8" OU T=6 96 .5 5 S MH RIM=7 08.45 8" IN =701.03 8" IN=701.15 8" O U T=700 .23 SMH R IM=713.55 6" OU T=707 .6 7 S W V G V S S W M W V W V W M W V W V W V W M S D S W V W V S GV W M W V S S W MWV S S MH RIM=7 11 .59 W M S W M W M S D W V G V G M W V C I T Y OF C HA R L O TTE 15 ' S AN I T A R Y S E WE R EA S E ME NT DEE D B OO K 129 0 , P AG E 3 3 3 50 ' P U B L I C R I G H T O F W AY (C .O .C .) C HA R L O TT E P I P E AN D C HA R L O T TE P I P E A N D C HA R L O TT E P I P E A N D D E E D B O OK 9 183 , P A G E 2 03 P A R C E L #0 7 3 2 6 2 32 C HA R LOTTE PIPE AND 1290, PAGE 400 DEED BOOK 50' PUBLIC RIGHT OF WAY (C.O.C.) H & S R O O F I NG C O . I ND U S T R I E S W H I TE C ON S O L I D A TE D 33 F OU N D R Y C O M P AN Y F OUND RY COM PANY F OU ND R Y C O M P A NY F O U N D R Y C O M P AN Y W H I TE C ON S O L I DA TE D I ND U S T R I E S P A R C EL #0 7 3 2 6 2 0 3 P A R C E L #07 3 2 6 20 7 P A RC E L #1 1 9 1 0 3 1 8 PARCEL #07326201 P A RC EL #0 7 3 26 21 5 B A S C O M V . B EL K P A R CEL #0 7 32 6 21 4 C HA R L O TT E P I P E AN D F OU N D R Y C O M P A NY P A RC EL #0 7 3 2 62 1 5 31 D 31 E C HA R L O T TE P I P E AN D F OU N D R Y C O M P AN Y P A RC EL #0 7 3 2 6 2 0 3 31 C 31 31 B 50 0 .6 1 + 48 .91 3 1 3 .7 6 + 8 0 .61 3 2 6 .62 + 5 5 .21 3 7 6 .3 6 + 89 .96 42 4 .09 + 8 9 .3 3 6 5 .48 + 72 .48 5 9 .94 + 5 3 .73 48 .31 + 56 .7 0 3 2 .3 5 + 2 2 .60 1 6 2 .0 5 + 7 2 .4 8 1 0 .7 3 + 2 8 .1 5 9 .46 + 72 .4 8 C C C C C C C 7 1 4 7 1 4 715715 7 1 6 7 1 6 7 1 6 7 1 6 7 1 7 71 7 7 1 7 7 1 7 71 7 7 1 7 718 7 1 8 718 718 7 1 8 718 719 719 719 719 719 719 72 0 720 720 72 0 720 720 72 1 7 2 1 721 72 1 7 2 1 721 7 2 2 7 2 2 7 2 3 7 2 3 72 4 7 2 4 72 4 7 2 4 725 7 2 5 725 7 2 5 72 7 72 7 728728 68 5 68 6 68 7 68 8 68 9 69 0 69 1 69 2 68 4 69 0 68 6 68 7 68 8 6 8 3 6 8 4 6 8 5 6 8 6 6 8 7 6 8 8 6 8 9 6 9 0 6 9 1 692.03 692.03 69 1 69 2 68 9 692.24 692.24 P F H 1 0 + 0 0 11 +00 0 +00 2 +0 0 1 +00 3 +0 0 4 +0 0 T G V P W M P R P Z 12 +00 14 + 00 15 +00 16 +00 LINE TO REMAIN EXIST. 8" WATER SEWER TO REMAIN EXIST. 8" SANITARY ABANDON SEWER MANHOLE OF 8" SEWER PIPE ABANDON SEWER MANHOLE OF 8" SEWER PIPE ABANDON SEWER MANHOLE OF 8" SEWER PIPE ABANDON SEWER MANHOLE W SUMMIT AVE P R O P . T R A C K #6 P R O P . T R A C K #5 P L A T F O R M P R O P . S T A T I ON P R O P . C U T /F I LL L I N E P R O P . T R A C K #5 N S R E X I S T . R /W P R O P . D I T C H P R O P . C U T / F I LL L I N E D R A I NA G E P ON D P R O P . S T O R M P R O P . D I T C H D R A I NA G E P ON D P R O P . S T O R M HYDRANT TO REMAIN EXIST. FIRE MANHOLE TO REMAIN SANITARY SEWER EXIST. PRIVATE MANHOLE TO REMAIN SANITARY SEWER EXIST. PRIVATE LINE TO REMAIN EXIST. 6" WATER SEWER SEE SHEET U10 PROP. 8" SANITARY SEWER TO REMAIN EXIST. SANITARY LINE TO REMAIN EXIST. WATER LINE TO REMAIN EXIST. WATER OF 8" SEWER PIPE ABANDONED METER/BOX TO BE SERVICE EXIST. 1" WATER ABANDONED METER/BOX TO BE WATER SERVICE EXIST. 1.5" REMAIN WATER METER TO EXIST. 3/4" ABANDONED METER/BOX TO BE WATER SERVICE EXIST. 1.5" REMAIN SERVICE TO EXIST. WATER OF 8" SEWER PIPE SEE SHEETS U8-U9 PROP. 6" WATER LINE REMAIN SERVICE TO EXIST. WATER WINONA ST S G R A H A M S T 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANSDO NOT USE FOR R/W ACQUISITIONPRELIMINARY PLANS MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/4/2016 10:40:07 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_sheet_11.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 WATER AND SEWER ABANDONMENT PLAN 1" = 40' N/A N/A 0 40 80 SCALE 1" = 40' 120 160 U12 M A T C H L I N E A B A N D O N M E N T P L A N S E E S H E E T U 1 1 NOT THE ITEM WAS SPECIFIED. FROM THE MANUFACTURER REGARDLESS OF WHETHER OR BE ACCOMPANIED WITH A LETTER OF CERTIFICATION REQUIREMENTS. EACH SHOP DRAWING SUBMITTAL SHALL ON THIS PROJECT SHALL MEET "BUY AMERICA" 1. ALL PRODUCTS, BUILDING MATERIALS, AND EQUIPMENT NOTES: 4" PVC S/L CO 700.94 690 6 9 0 695 695 695 695 695 700 700 700 700 700 7 0 0 700 7 0 0 700 700 705 7 0 5 7 0 5 705 705 705 705 705 705 705 705 710 710 7 1 0 7 1 0 7 1 0 710 7 1 0 710 710 71 0 710 715 7 1 5 715 7 1 5 7 15 715 71 5 715 7 2 0 7 2 0 7 2 0 7 2 0 72 0 7 2 0 720 720 725 7 2 5 725 725 7 2 5 72 5 7 25 7 3 0 73 0 730 735 7 3 5 7 4 0 S S S S C B 2 X EL M SMALL HARDWOODS S MHRIM=718.31 CL INV=710.09 RIM=713.98 8" INV IN=706.22 8" INV OUT=700.63 SMH RIM=701.98CL INV=694.10 SMH GREASE TR AP RIM=729.11 CL INV=727.11 SMHRIM=724.34 CL INV=720.83 SMHRIM=695.45 8" IN=686.05 8" OUT=681.97 SM HRIM=706.86 6" IN=704.11 SMHRIM=726.26 8" IN=719.47 8" IN=719.37 8" OU T=719.30 8" OUT=702.84 CB DI C B SMHRIM=699.78 12" IN=688.74 12" OUT=688.63 RIM=718.26 8" IN=708.23 12" OUT=701.47 12" IN=701.71 SMH S W M D S WV GV D D D W V WV WV G V W V G V GV WV D WV WV W V S S WV G M GV G V D WM WM WV WV WM WV GV WM S W V W V W M WV D WM GV WV S WM WM WV W V WM WM D RAILROAD STREET CLOSED 05/26/1998 RES. BK. 35, PG. 63 DEED BK. 9808, PG. 805 RAILROAD STREET (NEVER OPENED) RAILROAD STREET (NEVER OPENED) RAILROAD STREET (NEVER OPENED) W E S T P A L M E R S T R E E T C L O S E D 0 8/ 2 8/ 1 9 8 9 R E S. B K. 2 5, P G. 3 4 8 D E E D B K. 6 1 6 1, P G. 8 1 2 10' ALLEY CHA RLOTTE P IPE AND 40' PUBLIC RIGHT OF WAY (C.O.C.) R JS/STS LLC DEPARTMENT OF TRAN SPORTAT ION PARCEL #0732 6218 PROPERTIES LLCALBRIGHT P R O P E R T I E S L L C A L B R I G H T P R O P E R T I E S L L C A L B R I G H T M A N A G E M E N T L L C B U R K E M A N A G E M E N T L L C B U R K E T R A N S P O R T A T I O N D E P A R T M E N T O F H A L H. C ON R O Y DEPARTMENT OF TRAN SPORTAT ION PARCEL #0732 6220 P A R C E L # 0 7 3 2 6 2 2 0 P A R C E L # 0 7 3 2 6 2 2 1 P A R C E L # 0 7 3 2 6 2 2 2 P A R C E L # 0 7 3 2 6 2 2 3 P A RC EL #0 7326 2 1 7 PARCEL #07326225 P A R C E L # 0 7 3 2 6 2 2 4 PARCEL #073 26216 DEPARTMENT OF TRANSPORTATION PARCEL #07326226 #07326804 PARCELCOMPANYFOUNDRY PIPE ANDCHARLOTTE TRANSPORTATIONDEPARTMENT OF PARCEL #07326219 PARCEL #073 26219 TRAN SPORTAT ION DEPARTMENT OF RJS/STS LL C PARCEL #073 26216 32 32A 26 20A 20A 20B 20B 7 6 5 4 21D 3 31A TES TES TES TES 8 5 ' 1 1 5 ' 18.5000+36.80 18.5000 +29.24 102.99+07.80 123.60+03.66 271.56+53.25 64.53+39.45 2 87 .66 + 00 .5 8 2 0 1.16 + 30 .07 263 . 0 8 + 10 .77 3 4 7.46 + 82 .09 41 5.9 6 + 11.0 4 4 0 3.40 + 13 .2 4 18. 5 0 + 45 .2 0 32 . 00 + 4 5. 2 0 18.5 0 + 9 6.2 0 3 2. 0 0 + 96 .2 0 20.26 +13.39 26.72 +77.56 19.50 +00.00 8 5 ' 1 1 5 ' TES TES TES TES C C C 702 703 704 705 706 707 702 703 70 4 705 706707 707 7 1 6 7 1 6 7 1 7 7 1 7 722722 723723 724724 7 2 6 7 2 6 728728 729729 24.7-FT 18" RCP 715 .28 245.0-FT 18" RCP 692.78 692.78 693.83 696.27 696.16 34 .0-FT 18" RCP 699.68 700.83 700.71 701.84 696.89 694.64 694.64 694.04 694.04 693.44 693.44 692.84 692.84 201.6-LF 18" RCP 197-LF 18" RCP 197-LF 18" RCP G V GV LS R E M F H P F H 10+00 1 1 +0 0 1 0 + 0 0 1 1 + 0 0 1 2 + 0 0 0+00 1 + 0 0 2 + 0 0 0 + 0 0 1 + 0 0 0 + 0 0 LS 1 6 + 0 0 S S C O 1 2 +0 0 1 3 +0 0 1 3 + 0 0 1 4 + 0 0 1 5 + 0 0 1 7 + 0 0 3 + 0 0 4 + 0 0 5 + 0 0 2 + 0 0 LINE TO BE ABANDONED EXIST. 1 1/2" WATER SERVICE TO BE ABANDONED EXIST. WATER METER/BOX P E N M A N S T R E E T W P A L M E R S T T E M P O R A R Y C O N S T R U C TI O N E A S E M E N T PRO P. CUT/F ILL L INE PRO P. TRACK #6 PROP. TRACK # 7 PROP. TRACK # 5 PROP. TRACK #5 PROP. TRACK #6 PROP. TRACK #7 PROP. CUT/FILL LINE PROP. TRACK #5 PROP. TRACK #6 PROP. TRACK #7 PROP. D ITCH L INE PROP. DITCH LI N E E A S E M E N T E XI S T. W A T E R NSR EXIST. R/W NSR EXIST. R/W PROP. TRACK #5 PROP. TRACK #5 NSR EXIST. R/W PROP. DITCH PROP. DITCH PROP. CUT/FILL LINE NSR EXIST. R/W PROP. DITCH PROP. CUT/FILL LINE W P A L M E R S T NSR EXIST. R/W NSR EXIST. R/W PROP. CUT / F ILL L INE PROP. D ITCH PRO P. D ITCH PIPE DRAINAGE PROP . 18" HYDRANT TO REMAIN EXIST. FIRE LINE TO REMAIN EXIST. 8" WATER OF 8" SEWER PIPE OF 8" SEWER PIPE OF 12" SEWER PIPE ABANDON SEWER MANHOLE OF 12" SEWER PIPE ABANDON SEWER MANHOLE ABANDON SEWER MANHOLE OF 6" WATER PIPE OF 54" WATER PIPE SEWER TO REMAIN EXIST. SANITARY SEWER TO REMAIN EXIST. SANITARY LINE TO REMAIN EXIST. 6" WATER HYDRANT TO REMAIN EXIST. FIRE SEWER TO REMAIN EXIST. SANITARY SEWER TO REMAIN EXIST. SANITARY VALVE TO REMAIN EXIST. WATER VALVE TO REMAIN EXIST. WATER WATER VALVE ABANDON EXIST. WATER VALVE ABANDON EXIST. EXIST. FIRE HYDRANT ABANDON/REMOVE LINE TO REMAIN EXIST. 54" WATER WATER VALVE ABANDON EXIST. SEE SHEETS U5-U6 PROP. 6" WATER LINE SEE SHEET U4 PROP. 8" SANITARY SEWER LINE TO REMAIN EXIST. 54" WATER SEE SHEET U3 PROP. 54" WATER PIPE SEE SHEET U7 PROP. 18" SANITARY SEWER TO REMAIN WATER SERVICE EXIST. 3/4" TO REMAIN WATER SERVICE EXIST. 3/4" SERVICE TO REMAIN EXIST. 1" WATER TO BE ABANDONED METER ASSEMBLY FIRELINE SERVICE EXIST. 6" METER/BOX TO BE ABANDONED EXIST. 1" WATER SERVICE METER/BOX TO BE ABANDONED EXIST. 3/4" WATER SERVICE S GRAHAM ST 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANSDO NOT USE FOR R/W ACQUISITIONPRELIMINARY PLANS MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/4/2016 10:40:11 AM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CU_Utilities\Sheet File\4015156_WS_sheet_12.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) XIAOLIN DENG E NGINEER P R OFESS I ON A L N O RTH CAR O LIN A 034415 SEAL DocuSign Envelope ID: 284A8ECD-0EC1-4C57-B303-8087DF5FB93F 3/4/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 ELEVATION OF THRUST WALL END VIEW 3 " 1 2 ' - 0 " PLAN OF THRUST WALL 3 ' - 0 " SEE TIE ROD DETAILS TIE ROD DETAILS DETAIL AT RING PLATE DETAIL AT THRUST WALL RING PLATE DETAIL 4'-6•" INSIDE DIAMETER 6'-3•" OUTSIDE DIAMETER (FLANGE BOLTS NOT SHOWN FOR CLARITY) 9 SPA. @ 10"4 SPA. @ 1'-0" 2" CL. (TYP.) 8-#6 DIAGONAL BARS EACH FACE 3" HIGH BEAM BOLSTERS @ 4'-0" CTS. 3" GASKETS EACH SIDE. 1‚" RING PLATE W/ STD. PIPE SEE TIE ROD DETAILS RING WASHER DETAIL W/ WASHER DOUBLE HEX NUTS (SEE DETAIL) 1‚" RING PLATE W/ WASHER HEX NUT WASHER ƒ" RING W/ WASHER DOUBLE HEX NUTS F I E L D V E R I F Y T I E R O D L E N G T H FACE OF THRUST WALL 1" ~ TIE ROD 1" ~ TIE ROD 12- 1„" ~ HOLES FOR 1" ~ TIE RODS 44 - 2" ~ HOLES FOR FLANGE BOLTS (62.75 INCH DIAMETER) 1‚" RING PLATE 1 '- 6 Ž " 72 " D I A M ET E R C T S . (T Y P .) PIPE CONNECTION PLATE HOLES FOR HOLES SHALL MATCH FLANGE (THRUST WALL REINFORCING NOT SHOWN FOR CLARITY) (FLANGE BOLTS NOT SHOWN FOR CLARITY) WITH PVC PIPE SLEEVE (12) 1" ~ TIE RODS W/ EA. TIE ROD) PVC PIPE SLEEVE (TYP. ƒ" RING WASHER ƒ" RING WASHER 2 0 - # 9 H O R Z . B A R S E A . F A C E 3" HIGH BEAM BOLSTERS @ 4'-0" CTS. 18-#6 VERTICAL BARS EACH FACE SPACED AS SHOWN { PIPE NOTES: { PIPE BE TACK WELDED TOGETHER IN PLACE) (TWO RING WASHER SEGMENTS SHALL 1'-6" SOIL (TYP.) UNDISTURBED CL.CL. (UNDISTURBED SOIL NOT SHOWN FOR CLARITY) (CUT BARS 2" CLEAR OF CONCETE PIPE) (UNDISTURBED SOIL NOT SHOWN FOR CLARITY) (#6 DIAGONAL BARS NOT SHOWN FOR CLARITY) 6'-6" LONG. LONG. OUTSIDE DIAGONAL BARS SHALL BE CLOSEST TO CONCRETE PIPE SHALL BE 7'-0" VERTICAL BARS AS SHOWN. DIAGONAL BARS DIAGONAL BARS SHALL BE PLACED INSIDE (TYP.) MAX. VMW 8'-0"8'-0" 16'-0" 16'-0" 8'-0"8'-0" 4 ' - 0 " M I N . 6 ' - 0 " 6 ' - 0 " 1 2 ' - 0 " 7 • " 7 • " 7 S P A . @ 9 " 5 S P A . @ 6 " 5 S P A . @ 6 " 3 " C L . 3 " C L . 2 0 - # 9 H O R Z . B A R S E A . F A C E S P A C E D A S S HO W N 4 SPA. @ 1'-0" 6 "(T Y P .) (TYP.) 3" CL. EACH FACE #6 VERT. BARS (TYP.) #4 STIRRUS 2'-3"#4 STIRRUS SPA. 5 PAIRS - (TYP.) W/ VERTICAL BARS PEK KGB D E A D E N D EXIST. GROUND 10 ' - 0 " M A X . 54" ~ D.I. PIPE PCCP PIPE EXISTING 54" ~ PROPOSED GROUND { 54" ~ PCCP PIPE 6'-0" RADIUS 3" D.I. PIPE 54" ~ ADAPTER 54" DIP X PCCP ADAPTER 54" DIP X PCCP PCCP PIPE EXISTING 54" ~ THRUSTWALL DETAIL U13 THE ITEM WAS SPECIFIED. MANUFACTURER REGARDLESS OF WHETHER OR NOT LETTER OF CERTIFICATION FROM THE SUBMITTAL SHALL BE ACCOMPANIED WITH A AMERICA" REQUIREMENTS. EACH SHOP DRAWING EQUIPMENT ON THIS PROJECT SHALL MEET "BUY ALL PRODUCTS, BUILDING MATERIALS, AND BUY AMERICA NOTE 1 '- 6 Ž " 72 " D I A M ET E R C T S . (T Y P .) 12- 1„" ~ HOLES FOR 1" ~ TIE RODS 6'-6" OUTSIDE DIAMETER 5'-6" INSIDE DIAMETER SPLIT CENTERED BETWEEN HOLES BETWEEN HOLES SPLIT CENTERED ƒ" RING WASHER (TYP.) 2 " C L . (T Y P . ) 3'-0" UNLESS ALL SIGNATURES COMPLETED DOCUMENTS NOT CONSIDERED FINAL FOR CRANE SAFETY, SEE SEPCIAL PROVISIONS. FOR GROUT FOR STRUCTURES, SEE SEPCIAL PROVISIONS. FOR FALSEWORK AND FORMWORK, SEE SEPCIAL PROVISIONS. PROVISIONS. FOR SUBMITAL OF WORKING DRAWINGS, SEE SEPCIAL FOR THRUST WALL, SEE SEPCIAL PROVISIONS. EXCAVATION PER ALL OSHA AND STATE REGULATIONS. THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STEEL FOR THRUST WALL SHALL BE GRADE 60. CONCRETE FOR THRUST WALL SHALL BE CLASS A. REINFORCING STANDARD PROCTOR TEST. THRUST WALL PER 95% COMPACTION AS MEASURED USING THE BACKFILL SHALL BE INSTALLED AND COMPACTED AROUND FORMWORK FOR DETAILS. CONSTRUCTION, SEE SPECIAL PROVISIONS FALSEWORK AND TEMPORARY SHORING WILL BE REQUIRED FOR THRUST WALL AND SPECIFICATIONS. MINIMUM AND GALVANIZED PER CHARLOTTE WATER STANDARDS 1‚" RING PLATE AND ƒ" RING WASHER SHALL BE GRADE 50 BE GALVANIZED PER CMUD STANDARDS AND SPECIFICATIONS. EQUIVALENT HEX NUTS AND WASHERS. NUTS AND WASHERS SHALL 304 (125 KSI TENSILE STRENGTH) OR APPROVED EQUAL WITH 1" ~ TIE RODS SHALL BE ASTM A193 STAINLESS STEEL TYPE 6'-0" RADIUS 11. 10. 9. 8. 7. 6. 5. 4. 3. 2. 1. E. L KELLY,JR. APU19765 1-800-632-4949 AVOID UTILITY DAMAGE STOP BEFORE YOU DIG CALL NC ONECALL INCOMPLETE PLANS DO NOT USE FOR R/W ACQUISITION PRELIMINARY PLANS DO NOT USE FOR CONSTRUCTION MAINTENANCE FACILITY LOCOMOTIVE & RAILCAR 10+00 11+00 12+00 13+00 14+00 DateNo.RevisionBy CHARLOTTE WATER CHARLOTTE, NORTH CAROLINA Surveyed By Designed By Drawn By DateAs Built Hor. Vert. File No.Job No. PROFILE Scales PLAN Sheet Project-Engr Approved By Date Of C HA LO TTE TERWWW RH XMDSTV 13 A CITY OF CHARLOTTE DEPARTMENT DEWBERRY 3/3/2016 2:51:54 PM I:\Projects\4015156\4015156_0001\90_CAD Models and Sheets\04_CJ_Bridge\Thrust Wall\4015156_WS_sheet_13.dgn NC License Number F-0991 Charlotte, NC 28202 900 West Trade St., Suite 715 STV Engineers, Inc. 2/29/16CTH 7030600017-16-521 (S) 7030600038-16-011 (W) DocuSign Envelope ID: 8E4B1FAE-2B41-48B2-A792-C06AE3A9DBBA 3/3/2016 DocuSign Envelope ID: B40CF628-4E1E-40CB-8D2D-1BBAEDEA0469DocuSign Envelope ID: 1B7179B2-C9AC-41E5-A83E-4A50A54297B8 00 1 0 T _ P 0 8 Appendix B Project Schedule Pr o j e c t : P 8 - L R M F Pr i n t e d : 0 5 . 2 1 . 2 0 1 5 Pr i n t e d w i t h T I L O S 8 1 De s i g n D e v e l o p m e n t 06 . 0 1 . 2 0 1 5 3 0 0 7 . 1 0 . 2 0 1 5 2 Ow n e r R e v i e w 07 . 1 3 . 2 0 1 5 3 0 0 8 . 2 1 . 2 0 1 5 3 Co n s t r u c t i o n D o c u m e n t s 08 . 2 4 . 2 0 1 5 5 0 1 0 . 3 0 . 2 0 1 5 4 Ow n e r R e v i e w 11 . 0 2 . 2 0 1 5 3 8 1 2 . 2 5 . 2 0 1 5 5 Fin a l D o c u m e n t s A p p r o v a l 12 . 2 8 . 2 0 1 5 1 2 . 2 8 . 2 0 1 5 6 Bi d d i n g 12 . 2 8 . 2 0 1 5 2 0 0 1 . 2 2 . 2 0 1 6 7 Co n s t r u c t i o n C o n t r a c t s 01 . 2 5 . 2 0 1 6 3 0 0 3 . 0 4 . 2 0 1 6 8 Co n s t r u c t i o n N o t i c e t o P r o c e e d 03 . 0 7 . 2 0 1 6 0 3 . 0 7 . 2 0 1 6 9 DO T C o n s t r u c t i o n 03 . 0 9 . 2 0 1 6 2 7 7 0 3 . 3 0 . 2 0 1 7 10 Ma i n t e n a n c e F a c i l i t y - S i t e w o r k 03 . 0 9 . 2 0 1 6 1 0 4 0 8 . 0 1 . 2 0 1 6 11 De l a y E n t r y - S i t e W o r k 11 . 0 1 . 2 0 1 6 1 0 8 0 3 . 3 0 . 2 0 1 7 12 Ma i n t e n a n c e F a c i l i t y - B u i l d i n g 04 . 0 8 . 2 0 1 6 1 7 2 1 2 . 0 5 . 2 0 1 6 13 Ma i n t e n a n c e F a c i l i t y - S i t e W o r k 03 . 0 9 . 2 0 1 6 6 5 0 6 . 0 7 . 2 0 1 6 14 Tr a c k C o n s t r u c t i o n 03 . 1 7 . 2 0 1 6 1 7 4 1 1 . 1 5 . 2 0 1 6 15 CP L i d d e l l g r a d i n g - C o n t r a c t o r 03 . 1 7 . 2 0 1 6 5 3 0 5 . 3 0 . 2 0 1 6 16 Tr a c k W o r k - N S 05 . 3 0 . 2 0 1 6 1 2 2 1 1 . 1 5 . 2 0 1 6 17 Re p l a c e m e n t c a p a c i t y - N S 06 . 0 1 . 2 0 1 6 1 1 9 1 1 . 1 4 . 2 0 1 6 18 Ma i n t e n a n c e F a c i l i t y - N S 06 . 0 2 . 2 0 1 6 1 1 7 1 1 . 1 1 . 2 0 1 6 19 CP U p t o w n - N S 06 . 0 3 . 2 0 1 6 1 1 5 1 1 . 1 0 . 2 0 1 6 20 Fla g g i n g 03 . 0 9 . 2 0 1 6 2 8 0 0 4 . 0 4 . 2 0 1 7 21 Ut i l i t i e s 03 . 1 0 . 2 0 1 6 2 7 4 0 3 . 2 8 . 2 0 1 7 Ba r l i n e t i t l e S t a r t d a t e D u r a t i o n E n d d a t e Gr a p h i c s UtilitiesFlaggingCP Uptown - NSMaintenance Facility - NSReplacement capacity - NSTrack Work - NSCP Liddell grading - ContractorTrack ConstructionMaintenance Facility - Site WorkMaintenance Facility - BuildingDelay Entry - Site Work Maintenance Facility - Site workDOT Construction Co n s t r u c t i o n C o n t r a c t s Bid d i n g Co n s t r u c t i o n D o c u m e n t s Ow n e r R e v i e w De s i g n D e v e l o p m e n t Ow n e r R e v i e w 20 1 5 2016 2017 Ap r Ma y Ju n Ju l Au g Se p Oc t No v De c Ja n Fe b Ma r Ap r Ma y Jun Jul Au g Sep Oct Nov Dec Jan Feb Ma r Ap r Ma y Jun ... Pr o j e c t : P 8 - L R M F Pr i n t e d : 0 5 . 2 1 . 2 0 1 5 Pr i n t e d w i t h T I L O S 8 Appendix C Parcel Tables and Figures Parcel 31 Tables and Figures from H&H PSA report dated July 16, 2015 Table 2 (Page 1 of 2) Summary of Soil Analytical Results Charlotte Pipe and Foundry - Parcel 31 Charlotte, Mecklenburg County, North Carolina H&H Job No. ROW-506 Sample ID 31-1 31-2 31-3 31-4 31-5 31-6 31-7 31-8 31-9 31-10 31-11 31-12 Sample Depth (ft bgs) 5-7 5-7 5-7 2-4 3-5 0-2 3-5 0-0.5 0-2 0-2 0-2 0-2 0-2 4-6 Sample Date 6/10/2015 6/10/2015 6/10/2015 6/10/2015 6/11/2015 6/10/2015 6/10/2015 6/10/2015 6/12/2015 6/12/2015 6/12/2015 6/11/2015 6/11/2015 6/11/2015 PCBs (8082) (mg/kg) Total PCBs NA NA NA NA NA NA NA BRL NA NA NA NA NA NA 1 VOCs (8260) (mg/kg) Diisopropyl ether NA <0.0051 NA NA <0.0054 <0.0042 <0.0057 NA NA NA NA NA NA 0.0070 440 Methylene Chloride NA <0.0206 NA NA <0.0217 0.0247 <0.0228 NA NA NA NA NA NA <0.0187 57 m&p xylenes NA <0.0103 NA NA <0.0109 0.0167 <0.0114 NA NA NA NA NA NA <0.0094 110 o-xylene NA <0.0051 NA NA <0.0054 0.0086 <0.0057 NA NA NA NA NA NA <0.0047 130 Total xylenes NA <0.0103 NA NA <0.0109 0.0253 <0.0114 NA NA NA NA NA NA <0.0097 120 SVOCs (8270)(mg/kg) Acenaphthene <0.422 <0.449 <0.429 <0.428 NA NA NA 0.608 <0.377 <4.02 <0.471 <3.59 <0.490 <0.411 700 Anthracene <0.422 <0.449 <0.429 <0.428 NA NA NA 1.30 <0.377 <4.02 0.774 <3.59 <0.490 <0.411 3,400 Benzo(a)anthracene <0.422 <0.449 <0.429 <0.428 NA NA NA 10.6 0.625 <4.02 2.67 <3.59 <0.490 <0.411 0.15 Benzo(a)pyrene <0.422 <0.449 <0.429 <0.428 NA NA NA 9.33 0.586 <4.02 2.19 <3.59 <0.490 <0.411 0.015 Benzo(b)fluoranthene <0.422 <0.449 <0.429 <0.428 NA NA NA 12.2 0.826 <4.02 2.58 <3.59 <0.490 <0.411 0.15 Benzo(g,h,i)perylene <0.422 <0.449 <0.429 <0.428 NA NA NA 5.74 <0.377 <4.02 1.74 <3.59 <0.490 <0.411 NE Benzo(k)fluoranthene <0.422 <0.449 <0.429 <0.428 NA NA NA 7.31 <0.377 <4.02 1.61 <3.59 <0.490 <0.411 1.5 Chrysene <0.422 <0.449 <0.429 <0.428 NA NA NA 10.5 0.648 <4.02 2.47 <3.59 <0.490 <0.411 15 Dibenz(a,h)anthracene <0.422 <0.449 <0.429 <0.428 NA NA NA 1.13 <0.377 <4.02 0.476 <3.59 <0.490 <0.411 0.015 bis(2-ethylhexyl)phthalate <0.422 <0.449 <0.429 <0.428 NA NA NA 5.00 1.38 <4.02 <0.471 <3.59 <0.490 <0.411 38 Fluoranthene <0.422 <0.449 <0.429 <0.428 NA NA NA 16.1 1.02 <4.02 26.9 <3.59 <0.490 <0.411 460 Fluorene <0.422 <0.449 <0.429 <0.428 NA NA NA 0.484 <0.377 <4.02 <0.471 <3.59 <0.490 <0.411 460 Indeno(1,2,3-cd)pyrene <0.422 <0.449 <0.429 <0.428 NA NA NA 6.33 <0.377 <4.02 1.51 <3.59 <0.490 <0.411 0.15 Naphthalene <0.422 <0.449 <0.429 <0.428 NA NA NA 0.367 <0.377 <4.02 <0.471 <3.59 <0.490 <0.411 3.8 Phenanthrene <0.422 <0.449 <0.429 <0.428 NA NA NA 8.15 <0.377 <4.02 3.05 <3.59 <0.490 <0.411 NE Pyrene <0.422 <0.449 <0.429 <0.428 NA NA NA 13.0 1.11 <4.02 3.85 <3.59 <0.490 <0.411 340 HSL Metals (6010/7471) (mg/kg) Range (mg/kg) Mean (mg/kg) Antimony NA <0.57 NA NA NA NA NA 0.54 <0.38 0.53 <5.4 <0.49 <0.43 NA 6.2 <1.0-8.8 0.76 Arsenic NA <1.1 NA NA NA NA NA 2.1 1.1 2.3 <10.8 1.1 1.1 NA 0.67 1.0-18 4.8 Beryllium NA 0.29 NA NA NA NA NA 0.44 0.17 0.19 2.8 0.17 0.51 NA 32 n.d.-2.0 0.11 Cadmium NA 0.19 NA NA NA NA NA 0.47 0.17 0.30 <1.1 0.25 0.096 NA 14 1.0-10 4.3 Chromium NA 259 NA NA NA NA NA 90.6 21.6 15.1 1,010 13.0 63.3 NA 24,000 7.0-300 65 Copper NA 42.6 NA NA NA NA NA 32.4 29.3 24.7 35.4 40.8 30.7 NA 620 3.0-100 34 Lead NA 8.8 NA NA NA NA NA 142 11.9 30.7 64.5 6.3 12.3 NA 400 ND - 50 16 Manganese NA 539 NA NA NA NA NA 1,910 263 520 15,900 277 2,010 NA 360 8.0-3,394 594 Mercury NA 0.087 NA NA NA NA NA <0.0036 0.018 0.012 <0.0042 0.0070 0.043 NA 1.9 0.03-0.52 0.121 Nickel NA 10.2 NA NA NA NA NA 7.1 8.7 9.2 6.8 8.3 7.3 NA 300 n.d.-150 23 Selenium NA 1.8 NA NA NA NA NA <0.71 1.3 <0.97 <10.8 <0.99 0.89 NA 78 <0.1-0.8 0.42 Silver NA 1.0 NA NA NA NA NA 0.92 0.53 0.93 5.5 1.4 0.54 NA 78 ND-5.0 -- Zinc NA 17.4 NA NA NA NA NA 185 111 53.0 172 26.5 22.1 NA 4,600 25-124 56 Hexavalent Chromium (7196A) NA NA NA NA NA NA NA <2.71 NA <2.59 NA <2.50 NA NA 0.30 NE NE TPH-DRO/GRO (UVF) (mg/kg) Diesel-Range Organics (DRO) 0.29 0.88 6.7 2.3 0.34 518.5 <0.09NANANANANANA1.1 Gasoline-Range Organics (GRO) <0.71 <0.81 <0.71 <0.8 <0.85 <47.6 <0.24 NA NA NA NA NA NA <0.69 Notes: 1) Bold concentration indicates exceedance of NC DENR March 2015 IHSB Preliminary Industrial Health Based Soil Remediation Goals (or background levels in the case of metals) or NC DENR Action Levels 2) NC DENR IHSB Preliminary Health Based Residential Soil Remediation Goals - March 2015 3) NC DENR IHSB Protection of Groundwater Soil Remediation Goals - March 2015 4) Range and Mean background values for North Carolina or Southeast soils taken from Elements in North American Soils by Dragun and Chekiri, 2005 EPA Method follows parameter in parenthesis; NA= Not analyzed; NE = Not established; -- = Not Applicable; VOCs=volatile organic compounds; SVOCs=semi-volatile organic compounds; BRL=Below laboratory reporting limit TPH=total petroleum hydrocarbons; PCBs = polychlorinated biphenyls; HSL = Hazardous Substance List; UVF = Ultraviolet Fluorescence analytical method 31-13 Screening Criteria IHSB Industrial PSRG1 (mg/kg) IHSB Residential PSRG2 (mg/kg) IHSB POG3 (mg/kg) 10.14 1,900 0.32 640 0.023 390 NE 430 NE 260 5.8 9,000 8.4 46,000 660 2.9 0.18 0.29 0.059 2.9 0.60 NE 7,800 29 5.9 290 18 0.29 0.19 160 NE 6,000 330 6,000 56 2.9 3.5 17 0.21 NE 68 Background Metals in Soil44,600 220 94 0.90 3.0 5.8 460 63 200 3 100,000 360,000 9,400 700 800 270 5,200 65 8.0 1.0 10 4,400 130 1,200 2.1 1,200 3.4 6.3 3.8 70,000 1,200 NC DENR Action Level (mg/kg) 10 S:\AAA-Master Projects\NC DOT Right-of-Way -ROW\ROW-500s\ROW-506 P-3800 Parcels 31 & 31A Rail PSAs\Reports\Parcel 31\DataTables 2 & 3.xls 7/15/2015 Table 2 (Page 1 of 2) Hart & Hickman, PC Table 2 (Page 2 of 2) Summary of Soil Analytical Results Charlotte Pipe and Foundry - Parcel 31 Charlotte, Mecklenburg County, North Carolina H&H Job No. ROW-506 Sample ID Sample Depth (ft bgs) Sample Date PCBs (8082) (mg/kg) Total PCBs VOCs (8260) (mg/kg) Diisopropyl ether Methylene Chloride m&p xylenes o-xylene Total xylenes SVOCs (8270)(mg/kg) Acenaphthene Anthracene Benzo(a)anthracene Benzo(a)pyrene Benzo(b)fluoranthene Benzo(g,h,i)perylene Benzo(k)fluoranthene Chrysene Dibenz(a,h)anthracene bis(2-ethylhexyl)phthalate Fluoranthene Fluorene Indeno(1,2,3-cd)pyrene Naphthalene Phenanthrene Pyrene HSL Metals (6010/7471) (mg/kg) Antimony Arsenic Beryllium Cadmium Chromium Copper Lead Manganese Mercury Nickel Selenium Silver Zinc Hexavalent Chromium (7196A) TPH-DRO/GRO (UVF) (mg/kg) Diesel-Range Organics (DRO) Gasoline-Range Organics (GRO) 31-14 31-15 31-16 31-17 31-19 31-21 31-22 31-23 31-24 31-25 31-26 31-27 31-28 31-29 31-30 0-2 0-2 7-8 1-3 1-3 11-13 9-11 0-2 11-13 5-7 5-7 3-5 3-5 2-4 2-4 1-3 0-2 0-2 2-4 6/11/2015 6/10/2015 6/9/2015 6/9/2015 6/8/2015 6/8/2015 6/8/2015 6/11/2015 6/11/2015 6/10/2015 6/10/2015 6/10/2015 6/11/2015 6/10/2015 6/11/2015 6/9/2015 6/10/2015 6/11/2015 6/11/2015 NA NA NA NA NA NA NA NA NA NA NA NA NA BRL BRL NA NA NA NA 1 NA NA NA <0.0039 <0.0057 <0.0054 <0.0047 <0.0037 NA <0.0045 <0.0049 <0.0045 <0.0047 <0.0046 <0.0057 <0.0064 NA NA <0.0043 440 NA NA NA <0.0156 <0.0229 <0.0217 <0.0189 <0.0146 NA <0.0182 <0.0197 <0.0182 <0.0190 <0.0186 <0.0229 <0.0254 NA NA <0.0172 57 NA NA NA <0.0078 <0.0114 <0.0108 <0.0095 <0.0073 NA <0.0091 <0.0099 <0.0091 <0.0095 <0.0093 <0.0114 <0.0127 NA NA <0.0086 110 NA NA NA <0.0039 <0.0057 <0.0054 <0.0047 <0.0037 NA <0.0045 <0.0049 <0.0045 <0.0047 <0.0046 <0.0057 <0.0064 NA NA <0.0043 130 NA NA NA <0.0078 <0.0114 <0.0108 <0.0095 <0.0073 NA <0.0091 <0.0099 <0.0091 <0.0095 <0.0093 <0.0114 <0.0127 NA NA <0.0086 120 <0.369 <0.351 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 700 <0.369 <0.351 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 3,400 <0.369 0.382 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 0.15 <0.369 0.418 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 0.015 <0.369 0.621 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 0.15 <0.369 0.369 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 NE <0.369 <0.351 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 1.5 <0.369 0.417 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 15 <0.369 <0.351 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 0.015 <0.369 <0.351 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 38 <0.369 0.670 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 460 <0.369 <0.351 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 460 <0.369 0.366 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 0.15 <0.369 <0.351 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 3.8 <0.369 <0.351 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 NE <0.369 0.559 NA <0.379 <0.441 <0.447 <0.429 <0.371 NA <0.413 <0.377 <0.394 <0.425 <0.365 <0.416 <0.408 <0.375 <3.56 <0.388 340 Range (mg/kg) Mean (mg/kg) <0.51 0.43 NA <0.33 <0.48 0.81 <0.39 <0.31 NA <0.57 <0.52 <0.40 0.47 <0.30 0.84 1.1 0.86 0.87 0.60 6.2 <1.0-8.8 0.76 <1.0 2.8 NA 1.3 1.1 1.1 <0.78 1.5 NA <1.1 <1.0 <0.80 <0.72 <0.59 1.4 <0.95 1.4 3.7 1.1 0.67 1.0-18 4.8 0.36 0.13 NA 0.30 0.33 0.81 0.18 0.29 NA 0.63 0.32 0.20 0.37 0.18 0.61 0.56 0.13 0.17 0.14 32 n.d.-2.0 0.11 0.12 0.14 NA <0.065 1.6 0.14 <0.078 <0.062 NA 0.12 0.15 0.080 0.16 0.069 0.21 0.21 0.31 0.30 0.10 14 1.0-10 4.3 18.6 11.5 NA 9.5 16.1 22.8 9.7 38.5 NA 15.0 114 5.1 18.4 12.7 17.7 7.7 18.7 18.1 17.1 24,000 7.0-300 65 30.8 50.7 NA 9.7 26.6 41.9 15.1 11.4 NA 89.8 65.9 9.3 44.8 19.9 33.7 70.2 52.2 31.5 10.1 620 3.0-100 34 7.2 10.7 NA 7.0 51.0 5.1 9.1 7.7 NA 12.9 2.6 5.4 11.0 10.4 44.8 9.4 62.8 58.4 7.3 400 ND - 50 16 292 156 NA 76.4 156 236 121 258 NA 3,090 1,450 312 198 45.5 299 567 425 255 118 360 8.0-3,394 594 0.0061 <0.0050 NA 0.77 0.050 0.015 0.0079 0.019 NA 0.082 0.0090 0.022 0.040 0.028 0.060 0.0094 0.042 0.042 0.021 1.9 0.03-0.52 0.121 9.7 10.9 NA 1.5 6.2 35.9 2.5 3.8 NA 5.1 54.9 2.4 4.9 2.3 6.0 4.8 11.5 8.5 2.6 300 n.d.-150 23 <1.0 <0.66 NA <0.65 1.3 0.90 1.0 <0.62 NA 1.1 <1.0 0.94 1.2 0.68 <1.1 1.6 <0.73 <0.82 <0.75 78 <0.1-0.8 0.42 0.82 0.86 NA <0.33 <0.48 0.86 <0.39 <0.31 NA 0.98 0.89 0.61 0.90 <0.30 0.70 2.3 0.52 0.45 <0.38 78 ND-5.0 -- 34.5 31.8 NA 3.3 250 55.0 20.7 13.9 NA 20.4 57.8 35.7 34.1 14.6 57.1 67.3 71.5 106 20.9 4,600 25-124 56 <2.38NA NANANANANANANANANANANANANANANANANA 0.30 NENE NA NA <0.24 2.5 4.6 1 99.1 2.4 4.2 11.5 0.65 27.2 <0.3 0.59 <0.28 <0.41 49.3 NA 7.5 NA NA <0.59 <0.78 <0.58 <0.67 3.9 <0.73 <0.91 <0.59 <1.3 <0.87 <0.75 <1.5 <0.7 <1 <10.3 NA <0.65 Notes: 1) Bold concentration indicates exceedance of NC DENR March 2015 IHSB Preliminary Industrial Health Based Soil Remediation Goals (or background levels in the case of metals) or NC DENR Action Levels 2) NC DENR IHSB Preliminary Health Based Residential Soil Remediation Goals - March 2015 3) NC DENR IHSB Protection of Groundwater Soil Remediation Goals - March 2015 4) Range and Mean background values for North Carolina or Southeast soils taken from Elements in North American Soils by Dragun and Chekiri, 2005 EPA Method follows parameter in parenthesis; NA= Not analyzed; NE = Not established; -- = Not Applicable; VOCs=volatile organic compounds; SVOCs=semi-volatile organic compounds; BRL=Below laboratory reporting limit TPH=total petroleum hydrocarbons; PCBs = polychlorinated biphenyls; HSL = Hazardous Substance List; UVF = Ultraviolet Fluorescence analytical method 31-18 31-20 94 460 3 70,000 1,200 1,200 5.8 0.90 270 Background Metals in Soil4 17 2.9 0.18 290 18 700 5,200 800 9,400 360,000 IHSB Industrial PSRG1 (mg/kg) IHSB POG3 (mg/kg) IHSB Residential PSRG2 (mg/kg) NE 0.32 Screening Criteria 63 3.0 1,900 640 390 10.14 NE 29 660 8.4 430 260 5.8 0.29 2.9 0.023 NE 0.059 0.60 9,000 46,000 160 NE 0.29 7,800 5.9 0.19 6,000 330 NE 68 0.21 6,000 2.9 3.5 56 3.4 2.1 8.0 1.0 65 130 10 NC DENR Action Level (mg/kg) 4,400 4,600 220 200 1,200 10 100,000 3.86.3 S:\AAA-Master Projects\NC DOT Right-of-Way -ROW\ROW-500s\ROW-506 P-3800 Parcels 31 & 31A Rail PSAs\Reports\Parcel 31\DataTables 2 & 3.xls 7/15/2015 Table 2 (Page 2 of 2) Hart & Hickman, PC Table 3 (Page 1 of 1) Summary of Groundwater Analytical Results Charlotte Pipe and Foundry - Parcel 31 Charlotte, Mecklenburg County, North Carolina H&H Job No. ROW-506 S:\AAA-Master Projects\NC DOT Right-of-Way -ROW\ROW-500s\ROW-506 P-3800 Parcels 31 & 31A Rail PSAs\Reports\Parcel 31\DataTables 2 & 3 Table 3 (Page 1 of 1) Hart & Hickman, PC Sample ID MW-1 TMW-1 TMW-2 TMW-3 Screening Criteria Sample Date 6/12/2015 6/12/2015 6/12/2015 6/12/2015 NC DENR 2L Standard 1 Units mg/L mg/L mg/L mg/L mg/L VOCs (8260) Ethylbenzene <0.0010 <0.0010 0.0068 <0.0010 0.60 p-Isopropyltoluene <0.0010 <0.0010 0.0011 <0.0010 NS Methyl-tert-butyl-ether 0.0013 <0.0010 <0.0010 <0.0010 0.020 Naphthalene <0.0010 0.0039 0.0116 <0.0010 0.006 Styrene <0.0010 0.0013 <0.0010 <0.0010 0.070 Toluene <0.0010 0.0024 <0.0010 <0.0010 0.600 m&p Xylenes <0.0020 0.0024 <0.0020 <0.0020 NS o-xylene <0.0010 0.0012 <0.0010 <0.0010 NS Total Xylenes <0.0020 0.0036 <0.0020 <0.0020 0.500 SVOCs (8270)BRL NA BRL BRL varies HSL Metals (6010/7471) Copper <0.0050 NA 0.0064 0.0123 1.0 Lead 0.0098 NA <0.0050 <0.0050 0.015 Manganese 0.160 NA 1.88 3.15 0.050 Nickel <0.0050 NA 0.0075 0.0059 0.100 Zinc 0.396 NA 0.014 0.0240 1.0 Turbidity (NTU)0.80 8.00 7.37 9.96 NA Notes: 1. NC DENR 15A NCAC 2L .0202 Groundwater Quality Standards EPA Method follows parameter in parenthesis BRL=Below laboratory reporting limit; VOCs=volatile organic compounds; SVOCs=semi-volatile organic compounds Bold indicates above 2L Standard. NS = Not specified; NA = Not Applicable; NTU = Nephelometric Turbidity Unit Parcel 32 Tables and Figures from H&H PSA report dated December 1, 2014 Table 2 (Page 1 of 1) Summary of Soil Analytical Results RJS/STS, LLC Property - Parcel 32 Charlotte, Mecklenburg County, North Carolina H&H Job No. ROW-501 S:\AAA-Master Projects\NC DOT Right-of-Way -ROW\ROW-500s\ROW-501 P-3800 Charlotte Rail PSAs\Reports\Parcel 32\Soil DataTable 211/25/2014 Table 2 (Page 1 of 1) Hart & Hickman, PC Sample ID 32-2 32-3 32-4 32-5 32-6 32-7 32-8 32-9 32-10 32-11 32-12 32-13 32-14 32-15 32-16 32-17 32-18A 32-19A 32-20 Sample Depth (ft) 2-4 6-8 0-2 0-2 0-2 12-14 0-2 0-2 0-2 0-2 0-2 4-6 0-2 0-2 6-8 0-1.5 0-2 2-4 6-8 12-14 0-1 Sample Date 9/3/2014 9/3/2014 9/4/2014 9/4/2014 9/4/2014 9/4/2014 9/4/2014 9/4/2014 9/5/2014 9/5/2014 9/5/2014 9/5/2014 9/5/2014 9/5/2014 9/8/2014 9/5/2014 9/5/2014 9/5/2014 9/8/2014 9/8/2014 10/30/2014 RCRA Metals (7470/6010) TCLP (mg/L) Arsenic <0.050 NA NA NA NA NA NA <0.050 NA NA NA NA NA NA NA <0.050 NA NA NA NA NA Barium 3.8 NA NA NA NA NA NA 5.8 NA NA NA NA NA NA NA 0.61 NA NA NA NA NA Cadmium 0.21NANANANANANA0.47NANANANANANANA0.036NANANANANA Chromium <0.025 NA NA NA NA NA NA <0.025 NA NA NA NA NA NA NA <0.025 NA NA NA NA NA Lead 3.9NANANANANANA5.3 NA NA NA NA NA NA NA 398 NA NA NA NA NA Mercury <0.20 NA NA NA NA NA NA <0.20 NA NA NA NA NA NA NA <0.20 NA NA NA NA NA Selenium <0.10 NA NA NA NA NA NA <0.10 NA NA NA NA NA NA NA <0.10 NA NA NA NA NA Silver <0.025 NA NA NA NA NA NA <0.025 NA NA NA NA NA NA NA <0.025 NA NA NA NA NA PCBs (8082) (mg/kg) Aroclor 1016 <0.197 <0.042 <0.195 <0.183 <0.203 <0.0401 <1.79 <0.374 <0.210 <0.0453 <0.0437 <0.0410 <0.0421 <0.0395 <0.0422 <0.211 <0.177 <0.190 <0.0394 <0.188 <1.350 Aroclor 1221 <0.197 <0.042 <0.195 <0.183 <0.203 <0.0401 <1.79 <0.374 <0.210 <0.0453 <0.0437 <0.0410 <0.0421 <0.0395 <0.0422 <0.211 <0.177 <0.190 <0.0394 <0.188 <1.350 Aroclor 1232 <0.197 <0.042 <0.195 <0.183 <0.203 <0.0401 <1.79 <0.374 <0.210 <0.0453 <0.0437 <0.0410 <0.0421 <0.0395 <0.0422 <0.211 <0.177 <0.190 <0.0394 <0.188 <1.350 Aroclor 1242 <0.197 <0.042 <0.195 <0.183 <0.203 <0.0401 <1.79 <0.374 <0.210 <0.0453 <0.0437 <0.0410 <0.0421 <0.0395 <0.0422 <0.211 <0.177 <0.190 <0.0394 <0.188 <1.350 Aroclor 1248 <0.197 <0.042 <0.195 <0.183 <0.203 <0.0401 <1.79 <0.374 <0.210 <0.0453 <0.0437 <0.0410 <0.0421 0.485 <0.0422 <0.211 <0.177 <0.190 <0.0394 <0.188 <1.350 Aroclor 1254 <0.197 <0.042 <0.195 <0.183 <0.203 <0.0401 6.78 0.434 <0.210 <0.0453 <0.0437 <0.0410 <0.0421 0.334 <0.0422 <0.211 1.34 0.489 <0.0394 <0.188 6.33 Aroclor 1260 1.64 0.103 0.426 0.503 <0.203 <0.0401 <1.79 <0.374 <0.210 <0.0453 <0.0437 <0.0410 <0.0421 <0.0395 <0.0422 <0.211 <0.177 <0.190 <0.0394 <0.188 <1.350 Total PCBs 1.64 0.103 0.426 0.503 -- --6.78 0.434----------0.819----1.34 0.489 -- --6.33 VOCs (8260) (mg/kg) Acetone 0.276 <0.110 0.957 0.397 <0.0905 <0.106 0.191 0.726 <0.108 <0.0965 <0.112 <0.110 <0.106 <0.102 <0.0848 <0.134 <0.0833 <0.0926 <0.0804 <0.0880 <0.164 Benzene <0.0077 <0.0055 0.0083 <0.0065 <0.0045 <0.0053 <0.0060 <0.0061 <0.0054 <0.0048 <0.0056 <0.0055 <0.0053 <0.0051 <0.0042 <0.0067 <0.0042 <0.0046 <0.0040 <0.0044 <0.0082 2-Butanone (MEK) <0.153 <0.110 <0.163 <0.131 <0.0905 <0.106 <0.120 0.142 <0.108 <0.0965 <0.112 <0.110 <0.106 <0.102 <0.0848 <0.134 <0.0833 <0.0926 <0.0804 <0.0880 <0.164 n-Butylbenzene <0.0077 <0.0055 <0.0081 0.0227 <0.0045 <0.0053 <0.0060 <0.0061 <0.0054 <0.0048 <0.0056 <0.0055 <0.0053 <0.0051 <0.0042 <0.0067 <0.0042 <0.0046 <0.0040 <0.0044 <0.0082 Ethylbenzene <0.0077 0.0600 <0.0081 <0.0065 <0.0045 <0.0053 <0.0060 0.0122 <0.0054 <0.0048 <0.0056 <0.0055 <0.0053 <0.0051 <0.0042 <0.0067 <0.0042 <0.0046 <0.0040 <0.0044 <0.0082 p-Isopropyltoluene <0.0077 <0.0055 0.0217 0.0168 <0.0045 <0.0053 <0.0060 0.0291 <0.0054 <0.0048 <0.0056 <0.0055 <0.0053 <0.0051 <0.0042 <0.0067 <0.0042 <0.0046 <0.0040 <0.0044 <0.0082 Methylene Chloride <0.0307 <0.0220 <0.0326 <0.0261 <0.0181 <0.0211 <0.0241 <0.0242 0.0227 <0.0193 <0.0225 <0.0220 <0.0212 <0.0204 <0.0170 <0.0267 <0.0167 <0.0185 <0.0161 <0.0176 <0.0329 Naphthalene 0.0077 <0.0055 0.0682 0.0554 <0.0045 <0.0053 <0.0060 2.28 <0.0054 <0.0048 <0.0056 <0.0055 <0.0053 <0.0051 <0.0042 <0.0067 <0.0042 <0.0046 <0.0040 <0.0044 <0.0082 Toluene <0.0077 <0.0055 <0.0081 0.0138 <0.0045 <0.0053 <0.0060 0.0105 <0.0054 <0.0048 <0.0056 <0.0055 <0.0053 <0.0051 <0.0042 <0.0067 <0.0042 <0.0046 <0.0040 <0.0044 <0.0082 1,2,4-Trimethylbenzene 0.0101 <0.0055 0.0236 1.83 <0.0045 <0.0053 <0.0060 0.0322 <0.0054 <0.0048 <0.0056 <0.0055 <0.0053 <0.0051 <0.0042 <0.0067 <0.0042 <0.0046 <0.0040 <0.0044 <0.0082 1,3,5-Trimethylbenzene <0.0077 <0.0055 0.0105 0.204 <0.0045 <0.0053 <0.0060 0.0071 <0.0054 <0.0048 <0.0056 <0.0055 <0.0053 <0.0051 <0.0042 <0.0067 <0.0042 <0.0046 <0.0040 <0.0044 <0.0082 Total Xylenes 0.0129 0.186 <0.0163 0.285 <0.0090 <0.0106 <0.0120 0.0413 <0.0108 <0.0096 <0.0112 <0.0110 <0.0106 <0.0102 <0.0085 <0.0134 <0.0083 <0.0093 <0.0080 <0.0088 <0.0164 SVOCs (8270)(mg/kg) Benzo(a)anthracene <19.70 <0.402 6.42 <3.66 <4.06 <0.401 <3.58 <3.74 <0.42 <0.453 <0.437 <0.410 <0.421 <0.395 <0.422 <4.220 <0.353 <0.379 <0.394 <0.375 <6.760 Benzo(a)pyrene <19.70 <0.402 5.46 <3.66 <4.06 <0.401 <3.58 <3.74 <0.42 <0.453 <0.437 <0.410 <0.421 <0.395 <0.422 <4.220 <0.353 <0.379 <0.394 <0.375 <6.760 Benzo(b)fluoranthene <19.70 <0.402 4.34 <3.66 <4.06 <0.401 <3.58 <3.74 <0.42 <0.453 <0.437 <0.410 <0.421 <0.395 <0.422 <4.220 <0.353 <0.379 <0.394 <0.375 <6.760 Benzo(k)fluoranthene <19.70 <0.402 5.36 <3.66 <4.06 <0.401 <3.58 <3.74 <0.42 <0.453 <0.437 <0.410 <0.421 <0.395 <0.422 <4.220 <0.353 <0.379 <0.394 <0.375 <6.760 Chrysene <19.70 <0.402 6.97 <3.66 <4.06 <0.401 <3.58 <3.74 <0.42 <0.453 <0.437 <0.410 <0.421 <0.395 <0.422 <4.220 <0.353 <0.379 <0.394 <0.375 <6.760 bis(2-ethylhexyl)phthalate <19.70 <0.402 <3.90 <3.66 <4.06 <0.401 <3.58 <3.74 <0.42 0.764 <0.437 <0.410 <0.421 <0.395 <0.422 <4.220 <0.353 <0.379 <0.394 <0.375 <6.760 Fluoranthene <19.70 <0.402 13.80 <3.66 <4.06 <0.401 <3.58 <3.74 <0.42 <0.453 <0.437 <0.410 <0.421 <0.395 <0.422 <4.220 <0.353 <0.379 <0.394 <0.375 <6.760 Phenanthrene <19.70 <0.402 12.90 <3.66 <4.06 <0.401 <3.58 <3.74 <0.42 <0.453 <0.437 <0.410 <0.421 <0.395 <0.422 <4.220 <0.353 <0.379 <0.394 <0.375 <6.760 Pyrene <19.70 <0.402 12.40 <3.66 <4.06 <0.401 <3.58 <3.74 <0.42 <0.453 <0.437 <0.410 <0.421 <0.395 <0.422 <4.220 <0.353 <0.379 <0.394 <0.375 <6.760 HSL Metals (6010/7471) (mg/kg) Range (mg/kg) Mean (mg/kg) Antimony 11.9 <0.42 20.1 8.7 2.0 <0.55 60.9 20.2 6.9 <0.54 <0.60 <0.49 <0.64 <0.54 <0.52 238 8.4 <0.42 <0.43 <0.41 10.5 <1.0-8.8 0.76 Arsenic 13.4 1.2 12.8 8.9 1.4 1.2 9.6 15 1.9 <1.1 <1.2 <0.99 <1.3 2.3 <1.0 10.2 3.5 1.3 <0.87 <0.82 18.4 1.0-18 4.8 Beryllium 0.40 0.61 0.44 0.37 0.32 0.45 0.21 0.40 0.35 0.82 0.58 0.39 0.48 0.59 1.2 0.76 0.38 0.32 0.95 0.45 0.60 n.d.-2.0 0.11 Cadmium 35.9 1.7 42.5 421 <0.087 0.22 8.1 29.8 0.94 1.2 0.81 0.17 0.29 1.6 0.78 2.7 2.7 1.5 0.78 0.49 30.0 1.0-10 4.3 Chromium 100 9.1 68.4 56.1 19.8 6.7 45.1 97.6 11.9 53.8 138 8.6 12.2 77.7 11.2 71.0 83.2 17.8 21.7 4.7 114 7.0-300 65 Copper 550 42.3 1,310 543 39.7 22.0 253 2,420 320 75.4 70.1 32.9 84.3 116 39.8 2,520 306 109 35.3 35 1,100 3.0-100 34 Lead 2,580 85.3 2,200 1,290 237 9.1 3,780 2,290 2,260 14.8 125 4.9 143 223 45.5 28,700 402 253 5.0 68.8 3,100 ND - 50 16 Manganese 713 430 704 440 236 397 943 932 194 588 407 136 126 783 191 1,530 391 324 424 242 1,040 8.0-3,394 594 Mercury 0.17 0.067 0.24 0.29 0.044 <0.0041 0.32 0.37 0.27 0.083 0.052 0.0099 0.036 0.17 0.025 1.3 0.24 0.14 0.042 0.0051 0.72 0.03-0.52 0.121 Nickel 110 7.8 58.1 99.3 11.6 3.9 44.6 112 9.3 21.7 18.0 2.7 7.2 37.9 6 38.9 48.5 11.3 11.4 7.1 75.9 n.d.-150 23 Selenium 3.7 1.1 2.4 3.4 4.0 <1.1 1.4 2.8 <1.2 <1.1 <1.2 <0.99 <1.3 <1.1 <1.0 <1.2 <0.99 <0.85 <0.87 <0.82 <1.5 <0.1-0.8 0.42 Silver 0.65 <0.42 1.7 4.0 <0.43 <0.55 <0.44 1.6 <0.59 <0.54 <0.60 <0.49 <0.64 <0.54 <0.52 2.1 <0.50 <0.42 <0.43 <0.41 1.7 ND-5.0 -- Zinc 6,340 471 12,100 1,950 77.7 53.3 1,480 6,510 253 66.2 224 16.5 95.0 362 48.6 995 1,150 1,010 75.8 67.6 7,590 25-124 56 TPH-DRO/GRO (8015) (mg/kg) Diesel-Range Organics (DRO)4,330 71.7 1,180 1,180 66.9 <6.1 466 1,760 66.0 421 9.3 <6.2 <6.4 69.4 <6.4 385 63.8 148 <6.0 <5.7 1,040 Gasoline-Range Organics (GRO) <5.6 <6.9 15.1 58.7 <7.8 <6.9 <4.9 11.5 <8.0 <7.8 <6.4 <7.7 <6.6 <7.7 <5.7 <19.0 <5.0 <8.5 <4.5 <5.2 <11.3 Notes: Bold concentration indicates exceedance of IHSB Industrial PSRG (and twice mean background levels in the case of metals), RCRA Toxicity Characteristic, or NC DENR Action Levels 1. NC DENR Inactive Hazardous Sites Branch (IHSB) Preliminary Industrial Health Based Soil Remediation Goals - September 2014 2. NC DENR IHSB Protection of Groundwater Preliminary Soil Remediation Goals -September 2014 3. Range and Mean background values for North Caolina or Southeast soils taken from Elements in North American Soils by Dragun and Chekiri, 2005 EPA Method follows parameter in parenthesis; NA= Not analyzed; NE = Not established; -- = Not Applicable BRL=Below laboratory reporting limit; VOCs=volatile organic compounds; TCLP = Toxicity Characteristic Leeching Procedure SVOCs=semi-volatile organic compounds; TPH=total petroleum hydrocarbons; PCBs = polychlorinated biphenyls; HSL = Hazardous Substance List 63 1.0 65 270 700 360,000 3 3.0 70,000 1,200 1,200 5.8 0.90 1,200 3.4 2.1 130 3.1 5,200 800 9,400 100,000 200 32-1 Screening Criteria RCRA Toxicity Characteristic Level (mg/L) 5.0 100.0 1.0 5.0 5.0 0.2 1.0 5.0 IHSB Industrial PSRG1 (mg/kg) IHSB POG2 (mg/kg) -- -- -- -- -- -- -- -- -- -- -- -- -- -- 10.14 100,000 24 5.1 0.0073 28,000 16 110 2.4 25 8.1 NE 0.68 640 0.023 17 0.21 820 5.5 48 6.7 180 6.7 260 5.8 2.9 0.18 0.29 0.059 2.9 0.60 2.9 5.9 290 18 160 7.2 6,000 330 NE 6.8 Background Metals in Soil3 9.4 460 10 10 NC DENR Action Level (mg/kg) 4,400 4,600 220 Table 3 Summary of Groundwater Analytical Results RJS/STS, LLC Property - Parcel 32 Charlotte, Mecklenburg County, North Carolina H&H Job No. ROW-501 S:\AAA-Master Projects\NC DOT Right-of-Way -ROW\ROW-500s\ROW-501 P-3800 Charlotte Rail PSAs\Reports\Parcel 32\GW Analytical Table 3 Table 3 (Page 1 of 1) Hart & Hickman, PC Sample ID 32-TW1 Screening Criteria Sample Date 9/5/2014 NC DENR 2L Standard 1 Units mg/L mg/L PCBs (8082) Total PCBs BRL -- VOCs (8260)BRL -- SVOCs (8270)BRL -- Notes: 1. NC DENR 15A NCAC 2L .0202 Groundwater Quality Standards - April 2013 EPA Method follows parameter in parenthesis BRL=Below laboratory reporting limit; PCBs=polychlorinated byphenyls VOCs=volatile organic compounds; SVOCs=semi-volatile organic compounds Bold indicates above target screening levels. Parcel 32 Table and Figure from H&H Hazardous Soil Treatment and Removal Work Plan and Groundwater Results dated April 26, 2016 Table 1 Summary of Groundwater Analytical Results NC DOT Property - Parcel 32 Charlotte, Mecklenburg County, North Carolina H&H Job No. ROW-509 Sample ID 32-TW1 TW-2 Screening Criteria Sample Date 9/5/2014 3/31/2016 NC DEQ 2L Standard 1 Units mg/L mg/L mg/L PCBs (8082) Total PCBs BRL NA -- VOCs (8260)BRL NA -- SVOCs (8270)BRL NA -- Metals (6010/7470) -- Manganese NA 0.64 0.050 Nickel NA 0.0142 0.100 Zinc NA 0.0227 1.0 Lead NA <0.005 0.015 Turbidity (NTU)NA 8.02 NA Notes: 1. NC DEQ 15A NCAC 2L .0202 Groundwater Quality Standards - April 2013 EPA Method follows parameter in parenthesis NA = Not analyzed; NTU = nephelometric turbidity unit BRL=Below laboratory reporting limit; PCBs=polychlorinated byphenyls VOCs=volatile organic compounds; SVOCs=semi-volatile organic compounds Bold indicates above 2L Standard. Only compounds detected in at least one sample plus lead are shown above. S:\AAA-Master Projects\NC DOT Right-of-Way -ROW\ROW-500s\ROW-508 P-3800 CRISP BF Management\Hazardous Soil Removal Work Plan\Parcel 32 Soil & GW Tables.xls Table 2 (Page 1 of 1) Hart & Hickman, PC Appendix D Contingency Plan 1 S:\AAA-Master Projects\NC DOT Right-of-Way -ROW\ROW-500s\ROW-508 P-3800 CRISP BF Management\Revised EMP\Appendix E - Contingency\Contingency Plan.doc Contingency Plan NC DOT Charlotte Locomotive and Railcar Maintenance Facility Charlotte, Mecklenburg County, North Carolina H&H Job No. ROW-508 This Contingency Plan is being provided as required by the NC DEQ template Environmental Management Plan (EMP) for the proposed Charlotte Locomotive and Railcar Maintenance Facility for the Charlotte Railroad Improvement and Safety Program (CRISP) (NC DOT State Project P-3800). Contingency Actions In each of the contingent instances noted below, the Prospective Developer will notify DEQ within 48 hours per the accompanying EMP. If a sub-grade feature, structure, drum, underground storage tank (UST), or pit is encountered during construction, it will be inspected for the presence of product, waste, or contaminated fluids. If waste or contaminated fluids are present, they will be removed, profiled and disposed at a permitted facility. USTs will be removed and properly disposed in accordance with DEQ regulations. If the structure does not require removal for geotechnical or construction purposes, it will be filled with soil or suitable fill and construction will proceed. Where appropriate, the bottom may be penetrated before back filling to prevent rainwater accumulation. If waste is present, the waste will be set aside in a secure area and will be sampled as required by DEQ and disposed off-site. If a concrete structure must be removed and the observed waste characteristics indicate the concrete may potentially be contaminated to a significant degree, the concrete will be sampled and analyzed by methods specified by the disposal facility. If buried piping is encountered and must be removed to allow construction to proceed, the contractor will inspect the pipe for fluids, collect and sample fluids where appropriate, and 2 S:\AAA-Master Projects\NC DOT Right-of-Way -ROW\ROW-500s\ROW-508 P-3800 CRISP BF Management\Revised EMP\Appendix E - Contingency\Contingency Plan.doc look for signs of a release using field screening methods (visual, olfactory, field OVA). If a release is suspected, DEQ will be contacted to discuss the appropriate course of action. If suspected waste in soil is encountered at the site during construction, the soil may be stockpiled in a secure area and covered while awaiting characterization. Stockpiles will be covered with plastic sheeting, configured to minimize contact with surface flow, and additional measures taken as needed to prevent erosion. Sample results and the appropriate course of action will be discussed with DEQ. If landfilled material is encountered at the site during construction, the nature and extent of the buried material will be evaluated (ex. by test pits) and DEQ will be notified to discuss the appropriate course of action. Site debris will be segregated as needed, and disposed or recycled at an approved facility (or reused on site as beneficial fill at a location approved by DEQ). If a drum is encountered, the contents will be identified, and if appropriate, the drum profiled and disposed at a permitted facility. Potentially contaminated dirt will be shaken off of land clearing debris to the degree practical with land clearing equipment, and the land clearing debris disposed off-site at an approved land clearing and inert debris landfill. Open excavations associated with such instances above will be bermed or covered to minimize run-off in the event of substantial rainfall. In the event that impacted soil or water within an excavation cannot be dried adequately for construction purposes using the methods described in the accompanying EMP, the soil may be amended with clean soil, aggregate, drying agents, and/or stabilizing agents to achieve the desired geotechnical qualities. Amendment may be conducted inside or outside the excavation and the material replaced into the excavation. Such activities will be discussed with DEQ in advance.