HomeMy WebLinkAbout7906_Duke_DanRiver_RequestPhase1SubGrade_DIN27251_201701131 Frost, Larry From:Martin, Melonie Y <Melonie.Martin@duke-energy.com> Sent:Friday, January 13, 2017 10:50 AM To:Frost, Larry Subject:FW: Dan River Landfill Phase 1 Subgrade Attachments:GroundwaterSeparation_Contour.5.pdf; GroundwaterSeparation_Contour1ft.pdf Larry –     Please see the revised email below that addresses your comments.    Melonie   From: Martin, Melonie Y Sent: Friday, January 13, 2017 10:14 AM To: 'Frost, Larry' Subject: FW: Dan River Landfill Phase 1 Subgrade   Larry –     Below is a summary of what was discussed earlier this morning with Evan.  Please let me know if you concur  with this approach or if modifications are required for your approval.    Very respectfully,  Melonie   From: Andrews, Evan Sent: Friday, January 13, 2017 9:39 AM To: Martin, Melonie Y Subject: Dan River Landfill Phase 1 Subgrade   Melonie,    As you are aware, Transash is finalizing grading of the landfill subgrade for certification prior to the placement of  compacted clay liner.  Given the snow and freezing temperatures earlier this week, minor grading adjustments  (on the  order to ½”) are next to impossible.  Transash has requested that they be able to strip the subgrade up to 6” below the  permitted grades and begin the placement of the compacted clay liner at that, lowered, elevation.  AMEC provided the  attached file showing that there is ample separation between the permitted subgrade to allow for a slightly lower  elevation.  The basic process for liner construction would be as follows:    1. Clip wet material from the landfill base grades in phase 1 to achieve a solid, dry foundation up to 6” below the  permitted base grade.  This would only be done as needed and not across the entire phase.  Post settlement  slopes would be maintained to preserve permitted drainage flow paths.  2. Survey the new subgrade to establish a base line elevation to construction the remainder of the liner system  3. Verify that the revised grading will not result in the pooling or ponding of any leachate on the liner system.  4. Construct the 12” of 1x10‐5 from the lowered elevation  2 5. Construct the geosynthetics portion of the double liner system  6. Place intermediate cover in the cell to the permitted grades (thicker as needed in some areas to account for the  lower base grades) to achieve zero net gain in landfill airspace.    Please let me know if this is an acceptable approach or if there are any modifications required.    Thank you,    Evan Andrews, PE DUKE ENERGY Carolinas East Landfill Engineer CCP Engineering 3191 Pine Hall Rd. Walnut Cove, NC 27052 Office: 336-445-0734 Cell: 336-430-2988   Contour (.5ft) High : 40.7 Low : 5.3 21.5 19 12 10 22 19.5 17.5 15 2 2 .5 2 0 98 7 .5 23 2 0 .5 18 15.5 1 2 .5 2 3.52 1 16 11.5 11 1310.59.5 8.5 7 393 0 2 7 24 2 322 8 .5 8 1098 9 .5 7 9 8.5 16 14 13.5 9 .5 8.5 1 0 9 87.5 6.5 8.5 8 8.58 7.5 7 8 7 .5 27 24.5 25.524 20 18.5 14.5 13.5 17 1 6 .5 1 4 3 6 . 5 31 26.5 25 1 9 .5 1 7 7.5 1 0 .5 8 15 1 0 24 14 12.5 12 1 2 31 30.52928 24 1 7 1 7 1 6 1 6 1 6 1 5 14.5 14.5 15 13 12 12.5 12 1 2 .5 11 1 0 9 7 .5 7 3 8 . 5 37 30 2 1 .5 1 6 1 6 14.5 14.5 1 3. 5 14 1 1 .5 12 1 1 11 1 0 1 0 1 0 9 .5 1 0 9 . 5 9.5 7 .5 8 7 .5 7 3 2 33 3 2 .5 31 30.53027.5 29 26.5 26 25.5 2 5 17 1 6 1 6 1 5 13.5 13 13 1 1 11 1 1 .5 11.5 8 .5 9 9 8.5 9 99 9 8 8 7 .5 7 7.5 6 .5 7 7 6.5 6 Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/AirbusDS, USDA, USGS, AEX, Getmapping, Aerogrid, IGN, IGP, swisstopo, and theGIS User Community PREPARED BY: DATE: CHECKED BY: DATE: Dan River Steam StationLandfill Subgrade D o c u m e n t P a t h : F :\A M E C _P r o j e c t s \2 0 1 4 \7 8 1 0 -1 4 -0 0 6 5 D a n R i v e r P r o p o s e d L a n d f i l l \G I S \S e t t l e m e n t _2 0 1 5 1 1 1 0 \G r o u n d w a t e r S e p a r a t i o n .m x d PROJECT NO:7810-14-0065FIGURE NO: 0 200100Feet ± MS CR 1/11/2017 1/11/2017 Groundwater Separation 5 Elevation (ft) Contour (1ft) High : 40.7 Low : 5.3 2221201918 1615 23 1 7 1 09 8 3 0 24 13 3 1 25 1 41 2 31 2524 1614 11 1 0 9 8 1 09 1 0 8 8 7 8 7 8 7 28 2 6 8 7 29 2 8 26 2 1 2 220 1 6 27 15 1 4 3 6 30 24 24 1 7 1 7 1 6 1 6 1 6 1 5 14 1212 12 12 1 1 11 10 9 8 39 3 8 37 34 32 2927 2 3 1 6 15 15 13 13 12 11 1 1 11 1 0 1 0 1 0 9 9 9 9 999 9 8 8 8 8 7 7 Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/AirbusDS, USDA, USGS, AEX, Getmapping, Aerogrid, IGN, IGP, swisstopo, and theGIS User Community PREPARED BY: DATE: CHECKED BY: DATE: Dan River Steam StationLandfill Subgrade D o c u m e n t P a t h : F :\A M E C _P r o j e c t s \2 0 1 4 \7 8 1 0 -1 4 -0 0 6 5 D a n R i v e r P r o p o s e d L a n d f i l l \G I S \S e t t l e m e n t _2 0 1 5 1 1 1 0 \G r o u n d w a t e r S e p a r a t i o n .m x d PROJECT NO:7810-14-0065FIGURE NO: 0 200100Feet ± MS CR 1/11/2017 1/11/2017 Groundwater Separation 5 Elevation (ft)