Loading...
HomeMy WebLinkAbout7907_Stericycle_PTO_DIN26288_20161207 Permit No: 7907-TRANSFER-2016 Stericycle Environmental Solutions December 7, 2016 Document ID No.26288 Page 1 of 8 North Carolina Department of Environmental Quality Division of Waste Management Pat McCrory Donald R. van der Vaart Governor Secretary 1646 Mail Service Center, Raleigh, North Carolina 27699-1646 Phone: 919-707-8200 Internet: http://deq.nc.gov/about/divisions/waste-management/solid-waste-section An Equal Opportunity \ Affirmative Action Employer STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WASTE MANAGEMENT SOLID WASTE SECTION SOLID WASTE MANAGEMENT FACILITY STERICYCLE ENVIRONMENTAL SOLUTIONS (Operator) and EDMUND JIN and EVA LU (Landowners) are hereby issued a PERMIT APPROVAL TO CONSTRUCT Not Applicable PERMIT APPROVAL TO OPERATE 7907-TRANSFER-2016, Stericycle Environmental Solutions located at 211 Rockingham Drive, in Reidsville, Rockingham County, North Carolina, in accordance with Article 9, Chapter 130A, of the General Statutes of North Carolina and all rules promulgated thereunder and subject to the conditions set forth in this permit. The legal description of the site is identified on the deed recorded for this property listed in Attachment 1 of this permit. Edward F. Mussler, III, P.E. Permitting Branch Supervisor Solid Waste Section Permit No. 7907-TRANSFER-2016 Stericycle Environmental Solutions December 7, 2016 Document ID No. 26288 Page 2 of 8 ATTACHMENT 1 GENERAL PERMIT CONDITIONS INFORMATION Permit Status Issuance Expiration 7907-TRANSFER-2016 Active December 7, 2016 December 7, 2021 Part I General Facility 1. This permit is issued by the North Carolina Department of Environmental Quality, Division of Waste Management, Solid Waste Section (Section). In accordance with North Carolina Solid Waste Management Rule 15A NCAC 13B .0201(d), a solid waste management facility permit shall have two parts: a permit approval to construct and a permit approval to operate. The permit approval to construct must be implemented in accordance with Attachment 2 of this permit. The permit approval to operate must be implemented in accordance with Attachment 3 of this permit. 2. The persons to whom this permit is issued (“permittee”) are the owners and operators of the solid waste management facility. 3. This permit shall not be effective until the certified copy of this permit which references legal descriptions for all land within the solid waste management facility boundary is recorded in the Register of Deeds office and indexed in the grantor index under the name of the owner of the land in the county or counties in which the land is located. The certified copy of the permit affixed with the Register's seal and the date, book, and page number of recording must be returned to the Solid Waste Section within thirty (30) calendar days of issuance of this permit. If the Solid Waste Section does not receive the certified copy of the recorded permit within 30 calendar days of issuance of the permit, then and in that event, the permit is suspended and of no effect until the date the Solid Waste Section receives the certified copy of the recorded permit. 4. When this property is sold, leased, conveyed, or transferred in any manner, the deed or other instrument of transfer must contain in the deed description section, in no smaller type than that used in the body of the deed or instrument, a statement that the property has been used as a solid waste management facility and a reference by book and page to the recordation of the permit. 5. By initiating construction or receiving waste at this facility the permittee shall be considered to have accepted the terms and conditions of this permit. 6. Operation of this solid waste management facility shall be in accordance with the North Carolina Solid Waste Management Rules, 15A NCAC 13B; Article 9 of the Chapter 130A Permit No. 7907-TRANSFER-2016 Stericycle Environmental Solutions December 7, 2016 Document ID No. 26288 Page 3 of 8 of the North Carolina General Statutes (N.C.G.S. 130A-290, et seq.); the conditions contained in this permit; and the approved plan. Should the approved plan and the rules conflict, the Solid Waste Management Rules shall take precedence unless specifically addressed by permit condition. Failure to comply may result in compliance action or permit revocation. 7. This permit is issued based on the documents submitted in support of the application for permitting the facility including those identified in Attachment 1, “List of Documents for Approved Plan,” and which constitute the approved plan for the facility. Where discrepancies exist, the most recent submittals and the conditions of permit shall govern. 8. This permit may be transferred only with the approval of the Section, through the issuance of a new or substantially amended permit in accordance with applicable statutes and rules. 9. In accordance with N.C.G.S. 130A-295.2(g) the permittee shall notify the Section thirty (30) days prior to any significant change in the identity or business structure of either the owner or the operator, including but not limited to a proposed transfer of ownership of the facility or a change in the parent company of the owner or a change in the operator of the facility or parent company of the operator. 10. The permittee is responsible for obtaining all permits and approvals necessary for the development of this project including approval from appropriate agencies for a General or Individual National Pollutant Discharge Elimination System Stormwater Discharge Permit. Issuance of this permit does not remove the permittee’s responsibilities for compliance with any other local, state, or federal rule, regulation, or statute. PROPERTIES APPROVED FOR THE SOLID WASTE MANAGEMENT FACILITIES Rockingham County Register of Deeds Book Page Grantor Grantee Acres 1328 1399 New Fileas of America, Inc. Edmund Jin and Eva Lu 14.753 There is a warehouse building on the property and paved parking area. The solid waste activities will be conducted within the building. Permit No. 7907-TRANSFER-2016 Stericycle Environmental Solutions December 7, 2016 Document ID No. 26288 Page 4 of 8 Part II Transfer Station/Treatment & Processing Unit(s) Permitting History Permit Type Date Issued DIN Permit Approval to Construct and Permit Approval to Operate December 7, 2016 26288 DIN = Document Identification Number List of Documents for the Approved Plan 1. Solid Waste Transfer Station Permit Application for Stericycle Environmental Solutions, Inc. Prepared by Jeffrey Davis, Stericycle Environmental Solutions. Submitted February 2016. DIN 25953. - End of Section - ATTACHMENT 2 CONDITIONS OF PERMIT APPROVAL TO CONSTRUCT Part I: General Facility 1. The facility will be in an existing building and a permit to construct is not required. However, the facility must be inspected prior to beginning operation as noted in Attachment 3, Part VI, condition 2. -End of Section- Permit No. 7907-TRANSFER-2016 Stericycle Environmental Solutions December 7, 2016 Document ID No. 26288 Page 5 of 8 ATTACHMENT 3 CONDITIONS OF PERMIT APPROVAL TO OPERATE Part I: General Facility 1. The facility must be adequately secured by means of gates, chains, berms, fences, or other security measures approved by the Section to prevent unauthorized entry. 2. Signs must be posted at the entrance to the facility that state that no hazardous waste or liquid waste can be received at the facility; and provide information on dumping procedures, the hours of operation, the permit number, contact name, telephone number, and other pertinent information. Traffic signs or markers must be provided as necessary to promote an orderly traffic pattern to and from the discharge area and to maintain efficient operating conditions. 3. Interior roadway must be of all-weather construction and maintained in good condition. 4. A responsible individual trained and certified in facility operations must be on-site at all times during all operating hours of the facility, in accordance with N.C.G.S. 130A-309.25. An attendant must be present to oversee the loading and unloading of waste. 5. Copies of this permit, the approved plans, and all records required to be maintained by the permittee must be maintained at the facility and made available to the Section upon request during normal business hours. 6. All sedimentation and erosion control activities must be conducted in accordance with the Sedimentation Control Act, N.C.G.S. 113A-50 et seq., and rules promulgated under 15A NCAC 4. The Section must be notified of any approved modifications to the sedimentation and erosion control plan. 7. Facility construction, operations or practices must not cause or result in a discharge of pollution, dredged material, and/or fill material into waters of the state in violation of the requirements under Sections 401 and 4040 or the Clean Water Act, as amended. 8. Fire lanes must be established and maintained at all times. The dimensions of the fire lanes must be coordinated with the Fire Marshall having jurisdiction over the site. 9. Open burning of solid waste is prohibited. Fires must be reported to the regional waste management specialist with 24 hours or the occurrence, followed by a written notification within 15 calendar days of the occurrence. 10. Financial assurance as required by state rules and statutes must be continuously maintained for the duration of the facility and updated and submitted annually to the Section by the anniversary date of the issuance of this permit. Permit No. 7907-TRANSFER-2016 Stericycle Environmental Solutions December 7, 2016 Document ID No. 26288 Page 6 of 8 Part II: Transfer Station / Treatment and Processing Unit 1. The Permit to Operate shall expire December 7, 2021. No later than June 7, 2021, the permittee must submit a request to Section for a life-of-site permit in accordance with 15A NCAC 13B .0207(f). 2. A facility inspection and pre-operative meeting must be held onsite with key personnel and representatives of the Section prior to waste acceptance at the facility. It is the permittee’s responsibility to contact the Section and request the inspection. A representative of the Section will notify the Permitting Branch Supervisor in writing, either by letter or email, after the pre-operative meeting that the condition has been met. The owner and operator will be copied on the correspondence. The notification will serve as permission to operate the facility as of the date of the notification. A copy of the notification must be kept as part of the permanent record. 3. The facility is permitted to receive municipal solid waste as defined in N.C.G.S. 130A – 290 (a) (18a). 4. The following, at a minimum, must not be accepted for disposal at the facility: hazardous waste, yard trash, liquid wastes, regulated medical waste, sharps not properly packaged, regulated-asbestos containing material as defined in 40 CFR 61, PCB waste as defined in 40 CFR 761, and wastes banned from disposal in North Carolina by N.C.G.S. 130A-309.10(f). 5. The waste collected at this transfer facility must be transported to a sanitary landfill facility that is a. permitted to receive the type of waste specified, and b. whose service area includes the origin of the waste. 6. The permittee must not knowingly dispose of, or accept for transfer for subsequent disposal, municipal solid waste that is generated within the boundaries of a unit of local government that by ordinance: a. Prohibits generators or collectors of municipal solid waste from disposing of that type or form of municipal solid waste. b. Requires generators or collectors of municipal solid waste to recycle that type or form of municipal solid waste. 7. The permittee must develop and implement a training and screening program at the facility for detecting and preventing unauthorized wastes from being accepted at the facility. At a minimum, the program must include: a. Random inspections of incoming loads or other comparable procedures. b. Records of all inspections c. Training of personnel to recognize hazardous, liquid and other excluded waste types. d. Development of a contingency plan to properly manage any identified hazardous, liquid, or other excluded or unauthorized wastes. The plan must address identification, removal, storage and final disposition of these wastes. Permit No. 7907-TRANSFER-2016 Stericycle Environmental Solutions December 7, 2016 Document ID No. 26288 Page 7 of 8 8. The facility must not cause nuisance conditions. a. The tipping floor and transfer trailer loading area must be maintained in a clean, sanitary condition at all times and must be cleaned at least daily in accordance with the approved operation plan. b. Waste must only be deposited on a “tipping floor” or directly into a transfer container. Waste must not be stored on the “tipping floor” after operating hours. c. Waste may be stored on-site, in vehicles or containers that are constructed, operated, and maintained to be leak resistant in order to prevent the creation a nuisance to the public health from the escape of solid, semi-solid, or liquid waste a maximum of 72 hours when the facility is closed during a weekend or holiday. Storage of the waste must not cause any nuisance, such as odor or attraction of vectors. d. Effective vector control measures must be applied at all times to control any potential vectors including flies, rodents, insects, and other vermin. e. Control measures must be utilized to minimize and eliminate visible dust emissions and blowing litter. i) Fugitive dust emissions are prohibited. ii) Windblown materials must be collected by the end of the day and no windblown material may be allowed to leave the facility boundary. 9. All water that comes in contact with solid waste, including vehicle wash-down water, is leachate and must be captured and properly treated before release to the environment. a. The leachate control system, such as floor drains, leachate collection devices, sanitary sewer connections and leachate storage tanks, must be operational during facility operations. b. The tipping floor must drain away from the building entrance and into the leachate collection system. 10. The permittee must maintain a record of the amount of solid waste received at the facility, including daily records of waste received and origins of the loads. Scales must be used to weigh waste. The daily records are to be summarized into a monthly report for use in the required annual reports. 11. On or before August 1 annually, the Permittee must submit an annual facility report to the Solid Waste Section, on forms prescribed by the Section. a. The reporting period shall be for the previous year beginning July 1 and ending June 30. b. The annual facility report must list the amount of waste received in tons and be compiled: i) On a monthly basis. ii) By county, city or transfer station of origin. iii) By specific waste type. Permit No. 7907-TRANSFER-2016 Stericycle Environmental Solutions December 7, 2016 Document ID No. 26288 Page 8 of 8 iv) By receiving disposal facility. v) By diversion to alternative management facilities. c. The completed report must be forwarded to the Regional Environmental Specialist for the facility by the date due on the prescribed annual facility report form. d. A copy of the completed report must be forwarded to each county manager for each county from which waste was received at the facility. Documentation that a copy of the report has been forwarded to the county managers must be sent to the Regional Environmental Specialist by the date due on the prescribed annual facility report form. Part II: Miscellaneous Solid Waste Management 1. “Recyclable material” as defined in N.C.G.S. 130A-294(a)(26) and “recovered material” as defined in N.C.G.S. 130A-290(a)(24), may be received and processed as described in the documents for the approved plan. Recovered materials shall be cleared from the tipping floor at the end of each day and placed in a transfer trailer. 2. Recovered material must be managed as a valuable commodity in a manner consistent with the desired use or end use. 3. Seventy-five present (75%), by weight or volume, of the recovered material stored at the facility at the beginning of a calendar year commencing January 1, must be removed from the facility through sale, use, or reuse by December 31 of the same year. - End of Permit Conditions -