Loading...
HomeMy WebLinkAboutSDTF4902_INSP_20160310.pdfFACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 1 of 2 UNIT TYPE: Lined MSWLF LCID YW Transfer Compost SLAS COUNTY: Iredell Closed MSWLF HHW White goods Incin T&P FIRM PERMIT NO.: SDTF-49-02 CDLF Tire T&P / Collection Tire Monofill Industrial Landfill DEMO SDTF X FILE TYPE: COMPLIANCE Date of Site Inspection: March 10, 2016 Date of Last Inspection: November 19, 2015 FACILITY NAME AND ADDRESS: Lentz Septic Tank Service, Inc. 528 Sloans Mill Road Olin, North Carolina 28660 GPS COORDINATES: N: 35.98204° W: 80.84335° FACILITY CONTACT NAME AND PHONE NUMBER: Name: Keith Lentz Telephone: (704) 876-1834 Email address: keith@lentzseptic.com FACILITY CONTACT ADDRESS: 418 Lentz Road Statesville, NC 28625 PARTICIPANTS: Troy Harrison, NC Solid Waste Section Connie Wylie, NC Solid Waste Section Keith Lentz, Lentz Septic Tank Service, Inc.* *Spoke with Mr. Lentz prior to inspection at entrance to facility STATUS OF PERMIT: Active Issued: 3/11/2011 Expired: 3/14/2016* *Permit renewal submitted PURPOSE OF SITE VISIT: Routine Inspection Permit Renewal Inspection STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: N/A ADDITIONAL COMMENTS The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 2 of 2 1. All photographs were taken by Troy Harrison on March 10 2016. 2. This facility is currently permitted to operate two 10,000 gallon tanks and three 30,000 gallon tanks for the storage of domestic septage and grease trap pumpings. One 10,000 gallon tank has been removed and the other 10,000 gallon tank is for water only. 3. A screening box (box) was observed just under half full. Part of the top of the box was covered and inside of one corner was a six inch PVC pipe. There is a concern about vectors and how long the waste is stored in the box before disposal. According to Mr. Lentz, a bar screen has been ordered to place in the box for better collection of bigger trash items. A letter describing how the box is used has been received by the Solid Waste Section. A dumpster was observed nearby with no sign of septage waste just general solid waste. 4. Current Set-back/buffer requirements appear to have been met. 5. Appropriate signage (No Trespassing signs) is posted for the site. 6. All weather roads are maintained for access to the site. 7. The tanks appeared to be structurally sound. 8. The area around the detention and treatment area was found to be free of spills and debris. 9. Odors observed in the area of the detention and treatment area but not off property boundary. Please contact me if you have any questions or concerns regarding this inspection report. ___________________________ Phone: 828-296-4701 Troy Harrison Environmental Senior Specialist Regional Representative Sent on: April 7, 2016 X Email Hand delivery US Mail Certified No. [ _] Copies: Tony Gallagher, Composting & Land Application Branch Head Michelle Sclafani, Composting & Land Application Branch Connie Wylie, Composting & Land Application Branch