Loading...
HomeMy WebLinkAbout0601_AveryCountyLandfill_MSWLF_September2015_GW_GroundwaterMonitoring Report.pdf November 10, 2015 Ms. Jaclynne Drummond NCDENR DWM Solid Waste Section 2090 U.S. 70 Highway Swannanoa, North Carolina 28778-8211 RE: Operations, Monitoring, and Maintenance Report – October 2015 Avery County Closed MSW Landfill Spruce Pine, North Carolina Dear Ms. Drummond: Smith Gardner, Inc. (S+G) is pleased to present this report concerning the operation and maintenance (O&M) of the Avery County Closed MSW Landfill (Permit No. 06-01) Landfill Gas Collection and Control System (LFGCCS) and monitoring of the on- and off-site landfill gas probes for the October 2015 monitoring period. Mr. Spencer Hollomon with S+G performed the site visit on October 1, 2015. Site visit details are provided below. LFG EXTRACTION WELL MONITORING PROGRAM Monthly monitoring of the LFGCCS will continue and shall include the following items:  CH4, O2, CO2, and pressure monitoring at each extraction well head;  CH4, O2, CO2, and pressure monitoring at the flare station; and  Adjustment of the LFGCCS to balance recovery and ensure safe system operation. The County will maintain this LFGCCS and will continue to evaluate the effectiveness of increased LFG recovery from the waste mass in alleviating off-site LFG migration. Results from monthly monitoring events will be reported in accordance with the approved LFG Monitoring Plan. LFG EXTRACTION WELL MONITORING ACTIVITIES S+G personnel performed the flare station and well field monitoring on October 1st, 2015. Initial measurements indicated there was approximately 26 inches of available vacuum average throughout the well field, ranging from approximately 26 to 27 inches of available vacuum at each of the LFG wells across the well field. The results from this event are summarized below. Recommended actions are underlined. Well field data and flare station data are provided in the attached Table 1. Ms. Drummond November 10, 2015 Page 2 of 3 LFG Extraction Well Field  W-1 through W-10: S+G performed methane (CH4), oxygen (O2), carbon dioxide (CO2), and pressure monitoring. No adjustments were made to the extraction well heads during this monitoring event.  Orifice Plates: S+G continues to evaluate orifice plate sizes at wells W5, W7, W9, and W10 during each site visit. As LFG flow potential at these locations remains stable, the correct orifice plate sizes are currently installed. Flare Station  Condensate Tank: The condensate tank was observed during this site visit; the liquid was at an acceptable level. S+G will continue to monitor the liquid level of the condensate tank.  Filter Tank: The filter tank was observed during the October 2015 site visit and the liquid level was found to be at an acceptable level. S+G will continue to monitor the liquid level of the filter tank.  Flare operation: The flare was off when S+G arrived on-site, however the spark was working. The flare was not able to be ignited prior to S+G leaving the site. S+G will continue to adjust the system to optimize gas flow and quality. LFG MONITORING WELL (PERIMETER) MONITORING PROGRAM Mr. Hollomon performed monitoring of the perimeter LFG monitoring network during this event. Monitoring well P3 measured 5.4% by volume of CH4, which is over the 100% Lower Explosive Limit (LEL); wells P1, P7, and P13 measured 0.4%, 0.7%, and 1.1%, respectively, by volume of CH4. All other wells, monitored during this event, had no detectable concentrations of CH4. Results of this monitoring event are included in Attachment 1. Attachment 2 provides a CH4 concentration graph over time for monitoring wells that have historically had methane present. The current well network will continue to be monitored and data will be reported to NCDENR and the County. CONCLUSIONS Currently only P-3 has CH4 concentrations that exceed the LEL. This is an increase from recent events. We will continue to monitor the CH4 concentrations at the site monthly. The next routine monitoring event is scheduled for the second week of November 2015. If you have any questions, or require additional information, please contact us at your earliest convenience at 919-828-0577 or by e-mail (address below). Ms. Dr Novem Page 3 Sincer SMITH Don M Projec don@s Attach cc: E D fi rummond mber 10, 2015 3 of 3 rely, GARDNER, IN M. Misenheim ct Scientist, smithgardne hments Eric Foster – Deb Aja – NC le C. mer ext. 224 erinc.com Avery Coun DENR K:\Pro ty ojects\Avery County (N J S jo NC)\Avery-14-1 (LFG S oan A. Smyt Senior Hydro oan@smithg Sys Ops)\August 2015\ th, P.G. ogeologist ex ardnerinc.co \Avery Co MSW LFG M xt. 221 om onitoring Rpt August 22015.docx This page intentionally left blank. FIGURE This page intentionally left blank. 0 2 0 0 ' 4 0 0 ' 123 456 4 G:\CAD\Avery County\Avery 13-6\sheets\AVERY-B0216.dwg - 12/3/2013 11:03 AM           Th i s P a g e I n t e n t i o n a l l y L e f t B l a n k TABLE This page intentionally left blank. DATE: BY:SWH DataField - GEM Mode Data Output Date/Time CH4 CO2 O2 Balance Init. Temperature Init. Static Pressure Adj. Static Pressure Adj. Diff. Pressure* Init. Flow Adj. Flow System Pressure mm/dd/yyyy %%%%deg F in H2O in H2O in H2O Scfm Scfm in H2O AVERY-W1 10/1/2015 10:14 70.4 29.6 0 0 78 -26.83 -26.85 0.004 2.1 2.2 -27.2 AVERY-W2 10/1/2015 9:25 52 29.9 0.1 18 79 -26.21 -26.18 0.013 3.6 4.1 -26.17 AVERY-W3 10/1/2015 9:49 67.9 32.1 0 0 78 -26.09 -26.14 -0.002 <<>><<>>-26.03 AVERY-W4 10/1/2015 13:12 25.7 26.2 0.5 47.6 79 -23.21 -23.18 0.012 3.8 3.5 -26.8 AVERY-W5 10/1/2015 11:24 29.4 26.5 0.1 44 81 -25.32 -25.29 0.682 2.6 2.6 -26.14 AVERY-W6 10/1/2015 11:17 8.3 19.8 2.3 69.6 80 -6.58 -6.58 0.007 7 4.9 -26.06 AVERY-W7 10/1/2015 11:07 9.3 22.2 1.1 67.4 80 -12.85 -12.84 <<>>N/A N/A -26.12 AVERY-W8 10/1/2015 11:38 9 20.1 3.2 67.7 80 -24.11 -24.09 0 2.2 1 -26.7 AVERY-W9 10/1/2015 9:57 27.2 26.4 0.4 46 78 -26.03 -26 0.153 1 1.2 -25.89 AveryW10 10/1/2015 9:31 63.6 36.4 0 0 77 -26.21 -26.22 0.008 0.2 0.3 -26.24 Av-Flare 10/1/2015 11:44 15.7 14.8 7.3 62.2 NA 2.6 2.58 2.539 36 35.1 N/A <<>> = measurement out of range of GEM 2000 meter. The reading was likely too low for measurement by the instrument. Landfill Gas Collection and Control System Monitoring September 2015 *The differential pressure measurement should be positive. A negative differential pressure indicates no gas flow.   Negative differential pressure may be he result of dirt or water obstructing the pitot tube perforations.  Overpulling by adjacent extractions wells may also result in negative pressure being displayed. October 21, 2015 Avery County Closed MSW Landfill TABLE 1 Device ID Th i s p a g e i n t e n t i o n a l l y l e f t b l a n k . Attachment 1 This page intentionally left blank. NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: ______________________________________________ Permit Number: ____________________________ Date of Sampling: ___________________ NC Landfill Rule (.0500 or .1600): _____________________________________ Name and Position of Sample Collector: _________________________________________ Type and Serial Number of Gas Meter: _______________________________ Calibration Date of Gas Meter: ___________ Date and Time of Field Calibration: _____________________ Type of Field Calibration Gas (15/15 or 35/50): ____________ Expiration Date of Field Calibration Gas Canister: ________ Pump Rate of Gas Meter: _____________ Ambient Air Temperature: __________ Barometric Pressure: ______________ General Weather Conditions: _____________ Instructions: Under “Location or LFG Well” identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. __________________________________ ________________________ SIGNATURE TITLE NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: ______________________________________________ Permit Number: ____________________________ Date of Sampling: ___________________ NC Landfill Rule (.0500 or .1600): _____________________________________ Name and Position of Sample Collector: _________________________________________ Type and Serial Number of Gas Meter: _______________________________ Calibration Date of Gas Meter: ___________ Date and Time of Field Calibration: _____________________ Type of Field Calibration Gas (15/15 or 35/50): ____________ Expiration Date of Field Calibration Gas Canister: ________ Pump Rate of Gas Meter: _____________ Ambient Air Temperature: __________ Barometric Pressure: ______________ General Weather Conditions: _____________ Instructions: Under “Location or LFG Well” identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. __________________________________ ________________________ SIGNATURE TITLE NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: ______________________________________________ Permit Number: ____________________________ Date of Sampling: ___________________ NC Landfill Rule (.0500 or .1600): _____________________________________ Name and Position of Sample Collector: _________________________________________ Type and Serial Number of Gas Meter: _______________________________ Calibration Date of Gas Meter: ___________ Date and Time of Field Calibration: _____________________ Type of Field Calibration Gas (15/15 or 35/50): ____________ Expiration Date of Field Calibration Gas Canister: ________ Pump Rate of Gas Meter: _____________ Ambient Air Temperature: __________ Barometric Pressure: ______________ General Weather Conditions: _____________ Instructions: Under “Location or LFG Well” identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. __________________________________ ________________________ SIGNATURE TITLE Attachment 2 This page intentionally left blank. By:DMM Updated by:SWH Date:10/21/2015 Methane Concetrations Between May 2011 and October 2015 Landfill Gas Monitoring Well Network Avery County MSW Landfill 0 10 20 30 40 50 60 70 No v - 1 1 De c - 1 1 Ja n - 1 2 Fe b - 1 2 Ma r - 1 2 Ap r - 1 2 Ma y - 1 2 Ju n - 1 2 Ju l - 1 2 Au g - 1 2 Se p - 1 2 Oc t - 1 2 No v - 1 2 De c - 1 2 Ja n - 1 3 Fe b - 1 3 Ma r - 1 3 Ap r - 1 3 Ma y - 1 3 Ju n - 1 3 Ju l - 1 3 Au g - 1 3 Se p - 1 3 Oc t - 1 3 No v - 1 3 De c - 1 3 Ja n - 1 4 Fe b - 1 4 Ma r - 1 4 Ap r - 1 4 Ma y - 1 4 Ju n - 1 4 Ju l - 1 4 Au g - 1 4 Se p - 1 4 Oc t - 1 4 No v - 1 4 De c - 1 4 Ja n - 1 5 Fe b - 1 5 Ma r - 1 5 Ap r - 1 5 Ma y - 1 5 Ju n - 1 5 Ju l - 1 5 Au g - 1 5 Se p - 1 5 Oc t - 1 5 P1 P3 P7 P11 P12 P13 Well % CH4 by Volume Installation of W9 and W10 (April 30, 2013) Installation of W9/P3 Connection (September 11, 2014 Installation of P7/W8 and P1/W10 Connection (September 3, 2015) This page intentionally left blank.