HomeMy WebLinkAboutUniversity Ford Asbestos Report_20160726July 26, 2016
Mr. Peter McGrath
Moore & Van Allen PLLC
100 North Tryon Street, Suite 4700
Charlotte, North Carolina 28202-4003
Reference: Report of Asbestos Survey
601 Willard Street and 600 Julian Car Street
Durham, North Carolina
ASE Project No. 1272A
Dear Mr. McGrath:
Atlantic Shores Environmental Services, Ltd. (ASE) has completed an asbestos survey at the above
referenced property. The purpose of the testing was to determine the presence and general location of
asbestos containing materials (ACM) within the renovation area. This report includes a summary of the
project background information, our survey approach and sampling results, and conclusions and
recommendations.
PROJECT INFORMATION
The site includes approximately 11.19 acres of developed land located in downtown Durham, North
Carolina, adjacent to the west of the American Tobacco Historic District. Four structures currently occupy
the site. A Ford dealership and Kia dealership currently occupy the property. The structures include:
Ford Showroom/Office Space Building: This is an approximate 21,642 square-foot single-story
cinderblock and steel building constructed on a slab foundation. The roof is a combination gabled shingle
roof and flat rubber roof. This structure is utilized for both a showroom for University Ford (occupying
the southeast half of the building) and office space (occupying the north-northwest half of the building)
for University Ford employees. The building was reportedly built in 1973, with an addition to the north
side of the building in 1984.
Maintenance and Repair Building: This is a single story cinderblock and steel building encompassing
approximately 33,894 square-feet, with a mezzanine located within the eastern portion of the building.
This building was built in 1973 on a slab foundation with a metal roof.
Atlantic Shores
Environmental Services, Ltd.
154 Backhoe Road, L e land NC 28451 • P:(91 O) 3 71-5980 • F:(91 O) 3 71-6652
-A Woman Owned Business-
Report of Asbestos Survey July 26, 2016
601 Willard Street and 600 Julian Car Street
Durham, North Carolina
ASE Project No. 1272A
2
Paint and Auto body Building: This building is a single story cinderblock and steel framed building
encompassing approximately 16,200 square-feet in area. The structure was built in 1973 on a slab
foundation with a metal roof.
University Kia Showroom and Office Building: This building is a single-story cinderblock and steel
framed building encompassing approximately 3,500 square feet in area. It is used as a showroom and
office space for University Kia. According to the historical research conducted by ASE and the as-built
drawing, the eastern approximately 1,400 square-feet portion of this building was originally constructed
in 1973. The western portion of the building was constructed as an addition to the original building
around 2010. The building is constructed on a concrete slab foundation and has a flat rubber roof.
SCOPE OF SERVICES
The asbestos survey was performed by Cheryl Moody (North Carolina Asbestos Inspector No.12067) and
Mr. Elliot Swain of ASE on June 9 and 10, 2016. The survey consisted of observing the accessible areas of
the project area for the presence of suspect materials, which may contain asbestos. The survey involved
detecting both friable materials (materials which can be pulverized or reduced to a powder by hand pressure
when dry) and nonfriable materials (materials which pose a hazard when sawn, sanded, drilled or
pulverized). Homogeneous materials (based on material type, color, texture, etc.) were identified in various
functional spaces (bathroom, etc.) during the survey.
In order to determine if the suspect materials observed during the visual survey contained asbestos,
representative bulk samples were collected and placed in sealed packages. Sampling was performed to
National Emission Standard for Hazardous Air Pollutants (NESHAP) protocols.
Three samples of each suspect surfacing asbestos material or thermal system insulation (TSI) and one to two
samples of each suspect miscellaneous asbestos material were collected for laboratory analysis. One
hundred and eighty eight (188) bulk samples were collected during the survey and submitted to EMSL
Analytical, Inc. in Mooresville, North Carolina for analysis using the EPA recommended method of
Polarized Light Microscopy (PLM) coupled with dispersion staining (Method No. EPA 600/M4-020-82,
Dec. 1982). EMSL participates in the National Voluntary Laboratory Accreditation Program (NVLAP).
Their NVLAP accreditation number is 200671-0.
Several samples were layered and analyzed as multiple samples. A positive stop approach was used to
reduce sample costs. The EPA defines an asbestos-containing material as a material containing one
percent or more asbestos. EPA regulations require that multiple samples of each homogeneous area be
collected for laboratory analysis. If the first sample in each set of homogeneous materials is determined to
be asbestos-containing (1% or more asbestos), then the remaining samples in that set are presumed to be
asbestos-containing and the laboratory does not analyze them. Therefore, the laboratory analyzed 209
samples. In addition, six (6) samples were re-analyzed by the 400-point count method (with or without
gravimetric reduction) in an attempt to reduce the quantity of material requiring abatement prior to
renovation or demolition.
Ford Showroom/Office Building
Sampled materials from this building consisted of various floor tiles and mastic, wallboard, drywall/joint
compound, 2x2’ and 2x4’ ceiling tiles, exterior surfacing, window caulk, carpet mastic, baseboard mastic,
and roofing materials.
Report of Asbestos Survey July 26, 2016
601 Willard Street and 600 Julian Car Street
Durham, North Carolina
ASE Project No. 1272A
3
Maintenance and Repair Building:
Sampled materials from this building consisted of various floor tiles and mastic, HVAC duct tape,
drywall/joint compound, 2x4’ ceiling tiles, door sealant, wall joint sealant, window sealant and roofing
materials.
Paint and Auto body Building:
Sampled materials from this building consisted of floor tile and mastic, sink sealant, drywall/joint
compound, 2x4’ ceiling tiles, door sealant, baseboard mastic and roofing material.
University Kia Showroom and Office Building:
Sampled materials from this building consisted of floor tile and mastic, drywall/joint compound, 2x4’
ceiling tiles, exterior surfacing, exterior paneling, exterior caulk, baseboard mastic, and roofing materials.
RESULTS
The results have been presented in the attached Table 1. The EPA defines an asbestos-containing material
as a material containing one percent or more asbestos. ASE has listed both asbestos-containing materials
(>1% asbestos) and materials that contain trace amounts of asbestos (<1% asbestos) in the table.
Approximate quantities of asbestos containing building materials have been included in the table.
However, these quantities are rough estimates and should be quantified independently by any abatement
contractor. It should be noted that destructive testing was not conducted as part of this survey.
Ford Showroom/Office Building:
Asbestos containing building materials were not identified in the Ford Showroom/Office Building.
Maintenance and Repair Building:
Asbestos containing building materials identified in the Maintenance and Repair Building include:
•Floor tile mastic located beneath the 12x12 tile in the parts department.
•HVAC duct wrap located upstairs in the storage area.
•12x12 floor tile and mastic located in the shop technician locker room.
•Exterior sealant located between the metal exterior and cinderblock.
•Interior sealant located between the interior cinderblock wall and door on the southeast corner of
the shop.
Paint and Auto body Building:
Asbestos containing building materials identified in the Paint and Auto Body Building included:
•Exterior sealant located on the south entrance door.
•Penetration sealant located on fume hoods on the roof of the building.
•Roof sealant located down the length of the roof and on penetrations.
All penetration sealant on this roof should be assumed asbestos containing.
Report of Asbestos Survey July 26, 2016
601 Willard Street and 600 Julian Car Street
Durham, North Carolina
ASE Project No. 1272A
4
University Kia Showroom and Office Building:
Asbestos containing building material was not identified in the University Kia Showroom and Office
Building.
CONCLUSIONS AND RECOMMENDATIONS
Based on the results of our sampling, asbestos containing materials were identified at the site. The material
consists of as various 12x12 floor tile and mastic, interior and exterior sealants (this includes roofing
penetration sealants), and HVAC duct wrap.
If the above referenced asbestos materials are to be disturbed by renovations or demolition, the asbestos
must be removed in accordance with EPA, State of North Carolina and OSHA asbestos regulations. The
State of North Carolina, Health Hazards Control Unit (HHC) has specific regulations that must be
adhered to during asbestos removal/abatement projects.
The EPA and State of North Carolina defines an asbestos-containing material as a material containing one
percent or more asbestos. The EPA and State of North Carolina do not regulate a material containing less
than one percent asbestos and the abatement of the material is not required prior to renovation of the
structure.
Since the structure is scheduled for renovation and or demolition, we recommend the following:
1.Abate the friable and non-friable asbestos-containing materials in the structures prior to renovation or
demolition.
2.ASE can perform a final visual inspection after asbestos removal is completed and conduct clearance
testing during your abatement, as needed.
You should be aware that stringent requirements are imposed upon anyone renovating or demolishing a
structure in which ACM will be disturbed. This work must be performed in accordance with OSHA asbestos
regulations, 29 CFR 1910 & 1926, and NESHAP asbestos regulations 40 CFR 61, subpart M. North
Carolina regulations require the accreditation of personnel who work in the asbestos field and notification
and permitting fees for asbestos removal projects. There is a 10 working day notification period required
prior to abatement of more than 160 square-feet or 260 linear-feet of regulated asbestos in a facility. Failure
to take proper precautions and actions to protect human health and the environment can result in penalties,
danger to personnel, and construction delays.
Please note that this document is not a specification for asbestos removal. It does not contain means and
methods for asbestos abatement. If you are planning an asbestos abatement project, please contact ASE to
discuss the requirements. Use of this document without the express written consent of ASE is at the sole risk
of the user and or/abatement contractor.
This report summarizes our evaluation of the conditions observed at the site. The findings prepared by ASE
are based upon testing performed in the building. Additional ACM may exist (undetected) in other areas due
to their inaccessibility or due to the limited nature of our testing. Our recommendations are based on the
guidelines presented in EPA, State of North Carolina or OSHA asbestos regulations.
Use of this document without the express written consent of ASE is at the sole risk of the user. ASE
Report of Asbestos Survey July 26, 2016
601 Willard Street and 600 Julian Car Street
Durham, North Carolina
ASE Project No. 1272A
5
appreciates the opportunity to provide our environmental services for this project. If you have questions
or need additional information, please contact us at (910) 371-5980.
Respectfully,
ATLANTIC SHORES ENVIRONMENTAL SERVICES, LTD.
Cheryl J. Moody, REM, CMRS, CIEC Elliot Swain
Principal Scientist Staff Scientist
NC Asbestos Inspector No. 12067
Attachments: Bulk Asbestos Analysis Sheets
Asbestos Chain of Custody
Photographs
Table
Figure
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603738EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Attention:Phone:Cheryl Moody (910) 371-5980
Fax:Atlantic Shores Environmental Svcs., Ltd (910) 371-6652
Received Date:154 Backhoe Road 06/09/2016 5:00 PM
Analysis Date:Leland, NC 28451 06/10/2016
Collected Date:06/09/2016
Project:1272A
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
S-1A-Floor Tile
291603738-0001
None DetectedNon-fibrous (Other)100%Blue
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
Blue 12x12 FT
Female BR
S-1A-Mastic
291603738-0001A
None DetectedNon-fibrous (Other)98%Cellulose2%Tan/Clear
Fibrous
Homogeneous
University Ford
Showroom Building -
Blue 12x12 FT
Female BR
S-1B-Floor Tile
291603738-0002
None DetectedNon-fibrous (Other)100%Cellulose<1%Blue
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
Blue 12x12 FT Male
BR
Insufficient amount of mastic
S-2A
291603738-0003
None DetectedNon-fibrous (Other)93%Cellulose
Glass
5%
2%
Brown/Gray
Fibrous
Homogeneous
University Ford
Showroom Building -
Tile 12x12 Under
S-1AB FT
S-2B
291603738-0004
None DetectedNon-fibrous (Other)75%Cellulose
Glass
15%
10%
Brown
Fibrous
Homogeneous
University Ford
Showroom Building -
Tile 12x12 Under
S-1AB FT
S-3A-Floor Tile
291603738-0005
None DetectedNon-fibrous (Other)98%Cellulose2%White
Fibrous
Homogeneous
University Ford
Showroom Building -
White 12x12 FT
Storage Closet
S-3A-Mastic
291603738-0005A
None DetectedNon-fibrous (Other)97%Cellulose3%Tan
Fibrous
Homogeneous
University Ford
Showroom Building -
White 12x12 FT
Storage Closet
S-3B-Floor Tile
291603738-0006
None DetectedNon-fibrous (Other)98%Cellulose2%White
Fibrous
Homogeneous
University Ford
Showroom Building -
White 12x12 FT
Storage Closet
S-3B-Mastic
291603738-0006A
None DetectedNon-fibrous (Other)92%Cellulose8%Brown
Fibrous
Homogeneous
University Ford
Showroom Building -
White 12x12 FT
Storage Closet
S-4A
291603738-0007
None DetectedNon-fibrous (Other)78%Cellulose
Glass
20%
2%
White
Fibrous
Homogeneous
University Ford
Showroom Building -
Tongue & Groove
Wallboard Closet
Inseparable texture/coating layer included in analysis
S-4B
291603738-0008
None DetectedNon-fibrous (Other)78%Cellulose
Glass
20%
2%
White
Fibrous
Homogeneous
University Ford
Showroom Building -
Tongue & Groove
Wallboard Closet
Inseparable texture /coating layer included in analysis
Initial Report From: 06/13/2016 10:14:44
Page 1 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603738EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
S-4C
291603738-0009
None DetectedNon-fibrous (Other)77%Cellulose
Glass
15%
8%
Gray/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Tongue & Groove
Wallboard Closet
Inseparable texture /coating layer included in analysis
S-5A-Floor Tile
291603738-0010
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
Black Tile @ Closet
Door
S-5A-Mastic
291603738-0010A
None DetectedNon-fibrous (Other)95%Cellulose5%Beige
Fibrous
Homogeneous
University Ford
Showroom Building -
Black Tile @ Closet
Door
S-5B-Floor Tile
291603738-0011
None DetectedNon-fibrous (Other)100%Cellulose<1%Black
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
Black Tile @ Closet
Door
S-5B-Mastic
291603738-0011A
None DetectedNon-fibrous (Other)98%Cellulose2%Tan
Fibrous
Homogeneous
University Ford
Showroom Building -
Black Tile @ Closet
Door
S-6A-Floor Tile
291603738-0012
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
White Tile 12x12
Hallway
S-6A-Mastic
291603738-0012A
None DetectedNon-fibrous (Other)98%Glass2%Brown
Fibrous
Homogeneous
University Ford
Showroom Building -
White Tile 12x12
Hallway
S-6B-Floor Tile
291603738-0013
None DetectedNon-fibrous (Other)100%Cellulose<1%White
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
White Tile 12x12
Showroom
S-6B-Mastic
291603738-0013A
None DetectedNon-fibrous (Other)98%Cellulose2%Brown/Tan
Fibrous
Homogeneous
University Ford
Showroom Building -
White Tile 12x12
Showroom
S-7A-Floor Tile
291603738-0014
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
Gray Tile 12x12
Hallway
S-7A-Mastic
291603738-0014A
None DetectedNon-fibrous (Other)98%Cellulose2%Brown
Fibrous
Homogeneous
University Ford
Showroom Building -
Gray Tile 12x12
Hallway
S-7B-Floor Tile
291603738-0015
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
Gray Tile 12x12
Showroom
S-7B-Mastic
291603738-0015A
None DetectedNon-fibrous (Other)98%Cellulose2%Brown/Tan
Fibrous
Homogeneous
University Ford
Showroom Building -
Gray Tile 12x12
Showroom
S-8A-Floor Tile
291603738-0016
None DetectedNon-fibrous (Other)98%Cellulose2%Gray
Fibrous
Homogeneous
University Ford
Showroom Building -
Gray Tile 12x12
Lunch Room
Initial Report From: 06/13/2016 10:14:44
Page 2 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603738EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
S-8A-Mastic
291603738-0016A
None DetectedNon-fibrous (Other)98%Cellulose2%Brown
Fibrous
Homogeneous
University Ford
Showroom Building -
Gray Tile 12x12
Lunch Room
S-8B-Floor Tile
291603738-0017
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
Gray Tile 12x12
Lunch Room
S-8B-Mastic
291603738-0017A
None DetectedNon-fibrous (Other)98%Cellulose2%Brown/Tan
Fibrous
Homogeneous
University Ford
Showroom Building -
Gray Tile 12x12
Lunch Room
S-9A
291603738-0018
None DetectedNon-fibrous (Other)86%Cellulose
Glass
Wollastonite
12%
2%
<1%
White
Fibrous
Homogeneous
University Ford
Showroom Building -
Lunch Room DW/JC
This is a composite result of drywall, and joint compound.
S-9B
291603738-0019
None DetectedNon-fibrous (Other)85%Cellulose
Glass
Wollastonite
12%
3%
<1%
White
Fibrous
Homogeneous
University Ford
Showroom Building -
Hall DW/JC
This is a composite result of drywall, and joint compound.
S-9C
291603738-0020
None DetectedNon-fibrous (Other)77%Cellulose
Glass
Wollastonite
15%
8%
<1%
Gray/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Showroom DW/JC
This is a composite result of drywall, and joint compound.
S-10A
291603738-0021
None DetectedNon-fibrous (Other)5%Cellulose
Min. Wool
Glass
5%
60%
30%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Smooth CT 2x2 Hall
S-10B
291603738-0022
None DetectedNon-fibrous (Other)5%Cellulose
Min. Wool
Glass
5%
60%
30%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Smooth CT 2x2 Hall
S-10C
291603738-0023
None DetectedNon-fibrous (Other)15%Cellulose
Min. Wool
Glass
5%
60%
20%
Tan/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Smooth CT 2x2 Hall
S-11A
291603738-0024
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Smooth/Small Holes
CT 2x4 Hall
S-11B
291603738-0025
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Smooth/Small Holes
CT 2x4 Hall
S-11C
291603738-0026
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Gray/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Smooth/Small Holes
CT 2x4 Hall
S-12A
291603738-0027
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Large Hole CT 2x2
Hall
S-12B
291603738-0028
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Large Hole CT 2x2
Hall
S-12C
291603738-0029
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
White/Beige
Fibrous
Homogeneous
University Ford
Showroom Building -
Large Hole CT 2x2
Hall
Initial Report From: 06/13/2016 10:14:44
Page 3 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603738EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
S-13A
291603738-0030
None DetectedNon-fibrous (Other)90%Glass10%Gray/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Surfacing on Addition
S-13B
291603738-0031
None DetectedNon-fibrous (Other)100%Cellulose<1%White
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
Surfacing Showroom
S-13C
291603738-0032
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
Surfacing Showroom
S-14A
291603738-0033
None DetectedNon-fibrous (Other)97%Glass3%Gray
Fibrous
Homogeneous
University Ford
Showroom Building -
Grey Caulking
Window
S-14B
291603738-0034
None DetectedNon-fibrous (Other)97%Cellulose
Glass
<1%
3%
Gray
Fibrous
Homogeneous
University Ford
Showroom Building -
Grey Caulking
Window
S-15A
291603738-0035
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
White Caulking
S-15B
291603738-0036
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
White Caulking
S-16A
291603738-0037
None DetectedNon-fibrous (Other)98%Cellulose2%Tan
Fibrous
Homogeneous
University Ford
Showroom Building -
Carpet Mastic
S-16B
291603738-0038
None DetectedNon-fibrous (Other)95%Cellulose
Synthetic
2%
3%
Tan
Fibrous
Homogeneous
University Ford
Showroom Building -
Carpet Mastic
S-17A
291603738-0039
None DetectedNon-fibrous (Other)98%Cellulose2%Tan/White/Black
Fibrous
Homogeneous
University Ford
Showroom Building -
Baseboard Mastic
S-17B
291603738-0040
None DetectedNon-fibrous (Other)95%Cellulose5%Tan
Fibrous
Homogeneous
University Ford
Showroom Building -
Baseboard Mastic
S-18A-Floor Tile
291603738-0041
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
12x12 FT Black w/
Mastic
S-18A-Mastic
291603738-0041A
None DetectedNon-fibrous (Other)95%Cellulose
Synthetic
3%
2%
Black
Fibrous
Homogeneous
University Ford
Showroom Building -
12x12 FT Black w/
Mastic
S-18B-Floor Tile
291603738-0042
None DetectedNon-fibrous (Other)100%Brown/Tan
Non-Fibrous
Homogeneous
University Ford
Showroom Building -
12x12 FT Black w/
Mastic
S-18B-Mastic
291603738-0042A
None DetectedNon-fibrous (Other)95%Cellulose
Synthetic
2%
3%
Brown/Black
Fibrous
Homogeneous
University Ford
Showroom Building -
12x12 FT Black w/
Mastic
S-19A
291603738-0043
None DetectedNon-fibrous (Other)10%Cellulose
Min. Wool
Glass
10%
45%
35%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Smooth CT Show
Addition
Initial Report From: 06/13/2016 10:14:44
Page 4 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603738EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
S-19B
291603738-0044
None DetectedNon-fibrous (Other)10%Cellulose
Min. Wool
Glass
10%
45%
35%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Smooth CT Show
Addition
S-19C
291603738-0045
None DetectedNon-fibrous (Other)25%Cellulose
Min. Wool
Glass
5%
60%
10%
Tan/White
Fibrous
Homogeneous
University Ford
Showroom Building -
Smooth CT Show
Addition
SR-1A
291603738-0046
None DetectedNon-fibrous (Other)15%Cellulose85%Brown
Fibrous
Homogeneous
Showroom Bldg Roof
- Roofing Felts
SR-1B
291603738-0047
None DetectedNon-fibrous (Other)15%Cellulose85%Brown
Fibrous
Homogeneous
Showroom Bldg Roof
- Roofing Felts
SR-1C
291603738-0048
None DetectedNon-fibrous (Other)20%Cellulose80%Brown
Fibrous
Homogeneous
Showroom Bldg Roof
- Roofing Felts
SR-2A
291603738-0049
None DetectedNon-fibrous (Other)70%Cellulose30%Black
Fibrous
Homogeneous
Showroom Bldg Roof
- Tar/Tar Paper
SR-2B
291603738-0050
None DetectedNon-fibrous (Other)70%Cellulose30%Black
Fibrous
Homogeneous
Showroom Bldg Roof
- Tar/Tar Paper
SR-4A
291603738-0051
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
Showroom Bldg Roof
- Shingles Roof
SR-4B
291603738-0052
None DetectedNon-fibrous (Other)75%Cellulose
Glass
5%
20%
Black
Fibrous
Homogeneous
Showroom Bldg Roof
- Shingles Roof
SR-5A
291603738-0053
None DetectedNon-fibrous (Other)75%Glass25%Black
Fibrous
Homogeneous
Showroom Bldg Roof
- Tar Paper Under
Shingle
SR-5B
291603738-0054
None DetectedNon-fibrous (Other)85%Glass15%Various/Black
Fibrous
Homogeneous
Showroom Bldg Roof
- Tar Paper Under
Shingle
SR-6A
291603738-0055
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Showroom Bldg Roof
- Sealant by Addition
Light Grey
SR-6B
291603738-0056
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Showroom Bldg Roof
- Sealant by Addition
Light Grey
SR-7A
291603738-0057
None DetectedNon-fibrous (Other)100%Synthetic<1%Black
Non-Fibrous
Homogeneous
University Ford
Showroom Roof -
Sealant on AC (NW)
SR-7B
291603738-0058
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
University Ford
Showroom Roof -
Sealant on AC (NW)
SR-8A
291603738-0059
None DetectedNon-fibrous (Other)100%Cellulose<1%Gray
Non-Fibrous
Homogeneous
University Ford
Showroom Roof -
Sealant on AC (NE)
Dark Gray
SR-8B
291603738-0060
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
University Ford
Showroom Roof -
Sealant on AC (NE)
Dark Gray
Initial Report From: 06/13/2016 10:14:44
Page 5 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603738EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
SR-9A
291603738-0061
None DetectedNon-fibrous (Other)100%Gray/White/Blue
Non-Fibrous
Homogeneous
University Ford
Showroom Roof -
Surfacing on Parapit
Wall
Inseparable paint / coating layer included in analysis
SR-9B
291603738-0062
None DetectedNon-fibrous (Other)98%Glass2%Gray/White
Fibrous
Homogeneous
University Ford
Showroom Roof -
Surfacing on Parapit
Wall
SR-9C
291603738-0063
None DetectedNon-fibrous (Other)98%Glass2%Gray
Fibrous
Homogeneous
University Ford
Showroom Roof -
Surfacing on Parapit
Wall
SR-10A
291603738-0064
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
University Ford
Showroom Roof -
Sealant on Parapit
Wall
SR-10B
291603738-0065
None DetectedNon-fibrous (Other)100%Gray/Black
Non-Fibrous
Homogeneous
University Ford
Showroom Roof -
Sealant on Parapit
Wall
SR-11A
291603738-0066
None DetectedNon-fibrous (Other)98%Cellulose2%Black
Fibrous
Homogeneous
University Ford
Showroom Roof -
Sealant Around Patch
Work
SR-11B
291603738-0067
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
University Ford
Showroom Roof -
Sealant Around Patch
Work
SR-12A
291603738-0068
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Showroom Addition -
White Sealant Near
Additoin
SR-12B
291603738-0069
None DetectedNon-fibrous (Other)100%White/Black
Non-Fibrous
Homogeneous
Showroom Addition -
White Sealant Near
Additoin
SA-1A-Floor Tile
291603738-0070
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Showroom Addition -
Black FT
SA-1A-Mastic
291603738-0070A
None DetectedNon-fibrous (Other)95%Cellulose
Glass
3%
2%
Tan
Fibrous
Homogeneous
Showroom Addition -
Black FT
SA-1B-Floor Tile
291603738-0071
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Showroom Addition -
Black FT
SA-1B-Mastic
291603738-0071A
None DetectedNon-fibrous (Other)98%Cellulose2%Brown
Fibrous
Homogeneous
Showroom Addition -
Black FT
SA-2A-Floor Tile
291603738-0072
None DetectedNon-fibrous (Other)100%Cellulose<1%White
Non-Fibrous
Homogeneous
Showroom Addition -
White FT
SA-2A-Mastic
291603738-0072A
None DetectedNon-fibrous (Other)98%Cellulose2%Yellow
Fibrous
Homogeneous
Showroom Addition -
White FT
SA-2B-Floor Tile
291603738-0073
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Showroom Addition -
White FT
Initial Report From: 06/13/2016 10:14:44
Page 6 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603738EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
SA-2B-Mastic
291603738-0073A
None DetectedNon-fibrous (Other)98%Cellulose2%Yellow
Fibrous
Homogeneous
Showroom Addition -
White FT
SA-3A-Floor Tile
291603738-0074
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Showroom Addition -
Gray FT
SA-3A-Mastic
291603738-0074A
None DetectedNon-fibrous (Other)98%Cellulose2%Yellow
Fibrous
Homogeneous
Showroom Addition -
Gray FT
SA-3B-Floor Tile
291603738-0075
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
Showroom Addition -
Gray FT
SA-3B-Mastic
291603738-0075A
None DetectedNon-fibrous (Other)98%Cellulose2%Yellow
Fibrous
Homogeneous
Showroom Addition -
Gray FT
SA-4A
291603738-0076
None DetectedNon-fibrous (Other)85%Cellulose
Glass
Wollastonite
12%
3%
<1%
White
Fibrous
Homogeneous
Showroom Addition -
DW/JC
SA-4B
291603738-0077
None DetectedNon-fibrous (Other)85%Cellulose
Glass
Wollastonite
12%
3%
<1%
White
Fibrous
Homogeneous
Showroom Addition -
DW/JC
SA-4C
291603738-0078
None DetectedNon-fibrous (Other)75%Cellulose
Glass
20%
5%
Brown/White
Fibrous
Homogeneous
Showroom Addition -
DW/JC
AR-1A
291603738-0079
None DetectedNon-fibrous (Other)98%Glass2%White
Non-Fibrous
Homogeneous
Showroom Addition
Roof - Surfacing on
Side of Roof
AR-1B
291603738-0080
None DetectedNon-fibrous (Other)98%Glass2%Gray/White
Fibrous
Homogeneous
Showroom Addition
Roof - Surfacing on
Side of Roof
AR-1C
291603738-0081
None DetectedNon-fibrous (Other)98%Glass2%Gray
Fibrous
Homogeneous
Showroom Addition
Roof - Surfacing on
Side of Roof
AR-2A
291603738-0082
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Showroom Addition
Roof - Sealant at
Corner of bldg
AR-2B
291603738-0083
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Showroom Addition
Roof - Sealant at
Corner of bldg
AR-3A
291603738-0084
None DetectedNon-fibrous (Other)15%Cellulose85%Brown/Black
Fibrous
Homogeneous
Showroom Addition
Roof - Roofing Felts
AR-3B
291603738-0085
None DetectedNon-fibrous (Other)15%Cellulose85%Brown
Fibrous
Homogeneous
Showroom Addition
Roof - Roofing Felts
AR-3C
291603738-0086
None DetectedNon-fibrous (Other)20%Cellulose80%Brown
Fibrous
Homogeneous
Showroom Addition
Roof - Roofing Felts
AR-4A
291603738-0087
None DetectedNon-fibrous (Other)80%Cellulose20%Black
Fibrous
Homogeneous
Showroom Addition
Roof - Tar/Tar Paper
AR-4B
291603738-0088
None DetectedNon-fibrous (Other)80%Cellulose20%Black
Fibrous
Homogeneous
Showroom Addition
Roof - Tar/Tar Paper
AR-5A
291603738-0089
None DetectedPerlite
Non-fibrous (Other)
20%
5%
Cellulose75%Brown
Fibrous
Homogeneous
Showroom Addition
Roof - Roofing
Insulation
Initial Report From: 06/13/2016 10:14:44
Page 7 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603738EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
AR-5B
291603738-0090
None DetectedPerlite
Non-fibrous (Other)
20%
5%
Cellulose75%Brown
Fibrous
Homogeneous
Showroom Addition
Roof - Roofing
Insulation
AR-5C
291603738-0091
None DetectedPerlite
Non-fibrous (Other)
30%
10%
Cellulose60%Brown
Fibrous
Homogeneous
Showroom Addition
Roof - Roofing
Insulation
R-1A
291603738-0092
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Maintenance and
Repair Bldg - Black
FT 12x12
Insufficient amount of mastic for analysis.
R-1B-Floor Tile
291603738-0093
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Maintenance and
Repair Bldg - Black
FT 12x12
R-1B-Mastic
291603738-0093A
None DetectedNon-fibrous (Other)93%Cellulose
Glass
2%
5%
Red
Fibrous
Homogeneous
Maintenance and
Repair Bldg - Black
FT 12x12
R-2A
291603738-0094
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Maintenance and
Repair Bldg - Grey FT
12x12
Insufficient amount of mastic for analysis.
R-2B-Floor Tile
291603738-0095
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Maintenance and
Repair Bldg - Grey FT
12x12
R-2B-Mastic
291603738-0095A
None DetectedNon-fibrous (Other)98%Cellulose2%Yellow
Fibrous
Homogeneous
Maintenance and
Repair Bldg - Grey FT
12x12
R-3A
291603738-0096
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Maintenance and
Repair Bldg - White
FT 12x12
Insufficient amount of mastic for analysis.
R-3B-Floor Tile
291603738-0097
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Maintenance and
Repair Bldg - White
FT 12x12
R-3B-Mastic
291603738-0097A
<1% ChrysotileNon-fibrous (Other)98%Cellulose2%Orange
Fibrous
Homogeneous
Maintenance and
Repair Bldg - White
FT 12x12
R-4A
291603738-0098
25% ChrysotileNon-fibrous (Other)45%Cellulose30%Gray/White
Fibrous
Homogeneous
Maintenance and
Repair Bldg - HVAC
Duct Upstairs Storage
R-4B
291603738-0099
Positive Stop (Not Analyzed)Maintenance and
Repair Bldg - HVAC
Duct Upstairs Storage
R-4C
291603738-0100
Positive Stop (Not Analyzed)Maintenance and
Repair Bldg - HVAC
Duct Upstairs Storage
R-5A
291603738-0101
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
Maintenance and
Repair Bldg - 2x4 CT
Pits Dips
R-5B
291603738-0102
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
Maintenance and
Repair Bldg - 2x4 CT
Pits Dips
R-5C
291603738-0103
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
40%
30%
Gray/White
Fibrous
Homogeneous
Maintenance and
Repair Bldg - 2x4 CT
Pits Dips
R-6A
291603738-0104
None DetectedNon-fibrous (Other)80%Cellulose
Glass
15%
5%
White
Fibrous
Homogeneous
Maintenance and
Repair Bldg - DW/JC
Initial Report From: 06/13/2016 10:14:44
Page 8 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603738EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
This is a composite result of drywall, and joint compound.
R-6B
291603738-0105
None DetectedNon-fibrous (Other)80%Cellulose
Glass
15%
5%
White
Fibrous
Homogeneous
Maintenance and
Repair Bldg - DW/JC
This is a composite result of drywall, and joint compound.
R-6C
291603738-0106
None DetectedNon-fibrous (Other)75%Cellulose
Glass
20%
5%
Tan/White
Fibrous
Homogeneous
Maintenance and
Repair Bldg - DW/JC
This is a composite result of drywall, and joint compound.
RR-1A
291603738-0107
None DetectedNon-fibrous (Other)95%Synthetic5%Gray/White
Fibrous
Homogeneous
Maintenance and
Repair Bldg Roof -
Roofing Sealant/Paint
RR-1B
291603738-0108
None DetectedNon-fibrous (Other)97%Cellulose3%Gray/White
Fibrous
Homogeneous
Maintenance and
Repair Bldg Roof -
Roofing Sealant/Paint
RR-2A
291603738-0109
None DetectedNon-fibrous (Other)98%Cellulose2%Gray/White
Fibrous
Homogeneous
Maintenance and
Repair Bldg Roof -
Penetration Sealant
RR-2B
291603738-0110
None DetectedNon-fibrous (Other)100%White/Black
Non-Fibrous
Homogeneous
Maintenance and
Repair Bldg Roof -
Penetration Sealant
RR-3A
291603738-0111
None DetectedNon-fibrous (Other)98%Cellulose
Glass
2%
<1%
Gray/White
Fibrous
Homogeneous
Maintenance and
Repair Bldg Roof -
White Sealant
RR-3B
291603738-0112
None DetectedNon-fibrous (Other)96%Cellulose
Glass
2%
2%
Tan/Black
Fibrous
Homogeneous
Maintenance and
Repair Bldg Roof -
White Sealant
RR-4A
291603738-0113
None DetectedNon-fibrous (Other)80%Cellulose20%Black
Fibrous
Homogeneous
Maintenance and
Repair Bldg Roof -
Black Tar Under RR-3
RR-4B
291603738-0114
None DetectedNon-fibrous (Other)85%Cellulose15%Black
Fibrous
Homogeneous
Maintenance and
Repair Bldg Roof -
Black Tar Under RR-3
BR-1A
291603738-0115
15% ChrysotileNon-fibrous (Other)85%Gray/White/Black
Fibrous
Homogeneous
Auto Body Shop Roof
- Penetration Sealant
BR-1B
291603738-0116
Positive Stop (Not Analyzed)Auto Body Shop Roof
- Penetration Sealant
BR-2A
291603738-0117
5% ChrysotileNon-fibrous (Other)85%Cellulose10%Brown/White/Silver
Fibrous
Homogeneous
Auto Body Shop Roof
- Sealant (Brown) w/
Outer Layer
BR-2B
291603738-0118
Positive Stop (Not Analyzed)Auto Body Shop Roof
- Sealant (Brown) w/
Outer Layer
BR-3A
291603738-0119
None DetectedNon-fibrous (Other)60%Synthetic40%Gray/White
Fibrous
Homogeneous
Auto Body Shop Roof
- Surface Fabric
BR-3B
291603738-0120
None DetectedNon-fibrous (Other)80%Synthetic20%Gray
Fibrous
Homogeneous
Auto Body Shop Roof
- Surface Fabric
S-22A
291603738-0121
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom Bldg -
Addition Pitted CT
S-22B
291603738-0122
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom Bldg -
Addition Pitted CT
Initial Report From: 06/13/2016 10:14:44
Page 9 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603738EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
S-22C
291603738-0123
None DetectedPerlite
Non-fibrous (Other)
30%
10%
Cellulose
Min. Wool
40%
20%
Tan/White
Fibrous
Homogeneous
University Ford
Showroom Bldg -
Addition Pitted CT
Analyst(s)
Joshua Moorman (79)
Kelly Gallisdorfer (25)
Roxsee Stover (37)
Essie Spencer, Laboratory Manager
or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no
responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim
product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL
recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless
requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Morrisville, NC NVLAP Lab Code 200671-0, VA 3333 000278, WVA LT000296
Initial Report From: 06/13/2016 10:14:44
Page 10 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM
OrderID: 291603738
Page 1 Of 6
..... A-~-~-~"1.-IL_..._.,~-· -----~-~------,~SL ANALYTICAL, INC.
,.. Atlantic Shores Environmental Svcs .• Lid Order ID: 291603738 00 GATEWAY CENTRE
12m No samples: 120
Due: 06111 5:00 PM BLVD, SUITE 600 619/201617:0
PLM
TAT: 48 Hour
Bulk Fax: 91 D-371-6652 RRISVILLE, NC 27560 EM Wt . rlONE: (919) 465-3900
FAX: (919) 465-3950
EMSL-Bill to: l...'1'"5ame D Different
If 8111 to is Different note instructions in Comments** Comcanv: A ~)~,,,tc Shor(.() (.;M' . .-,~..,,,k,,\ Oisb"')
Street: )s'\ IS'",ti..,~ QJ. Third Parlv Bi/lino reauires written authorization from third oartv
Citv: l.<-l.,,J I State/Province: /J (, Zic/Postal Code: I Countrv:
Reoort To INamel: lhtrv\ ;t,J.nJ., Telechone #:
Fax#: I Purchase Order:
Proiect Name/Number: )l '1 J, A Please Provide Results: D Fax D Email
U.S. State Samples Taken: ~rr CT Samcles: D CommercialrTaxable D ResidentialrTax Exemct
Turnaround Time (TAT) Options* -Please Check
D 3 Hour I D 6 Hour I D 24 Hour I , x4a Hour I D 72 Hour I D 96 Hour I D 1 Week I D 2 Week
*For TEM Air3 hr through 6 hr, please call ahead to schedule ... ,here is a premium charge for3 Hour TEM AHERA or EPA Level II TAT. You will be asked to sign
an authorization form for this service. Analvsis comofeted in accordance with EMSL's Terms and Conditions located in the Anafvticaf Price Guide.
/ PLM • Bulk (reporting limit} TEM -Bulk
G"PlM EPA 600/R-93/116 (<1%) .......... ··········---··-··-····-·-................ 0 TEM EPA NOB -EPA 600/R-93/116 Section 2.5.5.1 ......... .
_g_1:'_1J,,1_E!'llf'l()E!(-<1'Y~L__ .. ...... ... . ...... .. ......... ........ . ... _D NY ELAPMethod198.4(TEM) ... ... .. ........... ...... ...... .. ..................... .
Point Count __ D_400 (<0.25%)_0_1000 (<0.1%)___ ......... _D_Chatfield_Protocol_(semi-quantitative) _____ .. ____ ............. .
_Point Count w/Gravimetric D 400_(<0.25%)_0 1000 (<0.1%) _D TEM_% by_Mass_-_EPA 600/R-93/1_16_Section 2.5.5.2 __
D NIOSH __ 9002 (<1_%L................. . ......... .... _ ...... D TEMQualitative via_Filtration Prep Technique ...... _
D NY ELAP Method 198.1 (friable in NY) D TEM Qualitative via Drop Mount Prep Technique
_ 0 NY ELAP Method 198.6. NOB (non-friable-NY)....... ....... ... ......... Other
O OSHA ID-191 Modified ----·-············-·····--··-····-··-·-·····--····--····· .. ·······························--·-· ··-·-····
D Standard Addition Method D
D Check For Positive Stop -Clearly ldentifv Homoaenous Group I Date Sampled:
Samplers Name: t/J.~I .)w.,'."'-L £, ', -;., / Ji2 v.rd, I Samplers Signature: . , .
Sample# HA# Samele Location Material Description
S-1 t3 l v
,,· /.e.
5-!iA
Client Sample# (s): ;::i-IA . ,,rs e --~ s Total# of Samples: 12..o
Relinquished (Client): /. Date: I, /tJcl /J 1., Time: JI] DS-
Received (Lab): A.A...---oate: 1" le, I Iv Time: S' Or--
Comments/Special Instructions: ( -l I .
Controlled Document-Asbestos COC -R2 -41912013
Page 1 of ___fu_ pages
OrderID: 291603738
Page 2 Of 6
Asbestos Bulk Building Material
Chain of Custody
EMSL ANALYTICAL, INC.
2500 GATEWAY CENTRE BLVD,
SUITE 600
WILLE, NC 27560
EMSL~
LA!lORATO
Atlantic Shores Environmental Svcs., Ltd
1272A
6/9/2016 17:0
PLM
TAT: 48 Hour
Bulk
Order ID: 291603738
No Samples: 120
Due: 06/11 5:00 PM
Fax: 910-371-6652
~E: 919-465-3900
l\X. § I §-455-3§55
Additiona, jJages OT Crlf:t L,/lt/111 UI \.JU.:>tvuy a11;; VIIJ.Y ,,....,...,,..,..,,.,o.J,J .. "~----. -----Jn
Sample# HA# Sam pie Location Material Descriotion
;i --5A \.)"':v,r;; :kj fo,J ;';'hov-> ttv= 1:?"11r"" fj),,,l ]c., 'I--·t-<. r@ c.1,s,} k,.r
I <..) ll h 5-513
C' -,
..J ~ ~
s-loA wk:t! ./-.'/.{. //..,(/) ]-\ .-.1 t vJ"""I
( s-(u l3 \A.l l: \;. \_.' l-i IJ.t)L c5!.,wl'c0,,.,
25-'/ A l., r," )-,'/'{. iJ.~ /). 1-1,,11 "'''Y
' ' -3. 'If 1._,.,..v /..,'k Ux/L 31..a"-'.,,. ,__
5 -6"A '/_,,.,, )-. h 1µ/L .£ n t /,._ tr""',_
6-_158 \ ._' . 7;
S-9A l v" l !,, rov,.,. ))\;-' /., (
.5-91-3 l-1,,,, ~"'-' / ~ (.
5-9t. 5 h11,-,Jv J ·"-))Vu/:,(,
s-1 oA Svi,,wiLc CT J,xQ_ /~,a.ll
5-to G "' {;
<;;· Io l " 1, ' ·.'
3'-II A 5...,..,1,1./~.,.,. lot~ GT 2.,<L ,~
5.11 0 \<.-"''
S-l·IC lL ;!;
,')-)LA .l.J-c,_, l.o lt. c, l,< k. 1-t.,, l l
S-11 y ,, Jl
~ .....
,5-ltl < LL .t I
5-)3A 5,1f..c:.,_, """ t,.,U_.·P-~
:5-IJ 13 ;)vJf..,,.<\ ,Jt...av-> n,o,,.,_
< ' / ..
7-le) '--~ . ,,
•comments/Special Instructions:
Page _1_ of __k_ pages
controlled Document -Asbestos COC-R2-41912013
OrderID: 291603738
Page 3 Of 6
...A.. Asbestc:,.s Bulk Building Material
~ OrderlD: 291603738
EMSL ANALYTICAL, INC .
'~y CENTRE BLVD,
SUITE 600
/ILLE, NC 27560 , Atlantic Shores Environmental Svcs., Ud No samples: 120
1272A Due: 06/11 5:00 PM ~ TAT: 48 Hour 371-6652 I.ABORATORV 6191201617:0 Fax: 910-______ Bulk
PLM
_;: 919-465-3900
FAX. !3 I §-4C>a-3!:!0a
Additiona, , a>J"'" u1 me c;nain of Custody are only necessary if needed for additional sample information
Sample# HA# Samele Location Material Descriotion
S-1'-IA LJ Y1 ) ii !<) : !"I F~rJ :J "'""""°"" 6.,: I J.',0 1 l nN.,1 (c,i u l I:.'~· .{!J; v..do vV
5-1 J.J '.8
,J l .J 'z _,
S-JS'A ~ \,...l l,c_ {,,.~Jtc!,,
5-15 JJ L\ -.., 1t
S-Ji A (r,.r\l l-1'1"'5 <-c
s-n .ls \, 1;
5 -1'],l\ g., t t.1:, o«r J. )1..SL'r._
5-l'l /J ,, '1
S-17 A J)x!J. [.T J/n d-, ,1,v/ ,r,w;s /_1-(._
5-17 t3' \\ //
5-/q,/.l 5-noo t,k. c, ohoiP c..dd ,'/."-.
6-)q L? \C ,:./
s-,q c. \ I VI. ,,
jg· lA S hw· t""""' !JIJ._ 'f2.oof fo.A-<,,,, J_,_ I \.;i
v '-J
~f -I !3 IC /,
Sf<!· IL \\ ,,
5fL-~A lw / /,,r ;,~pv-.
l.51e-JG \\ I·
ISQ-1-\ A :51,,1.._~,,-{Rovf)
5(l-'-11? ,, v t, .....
5(2.-s---A f,,.r ,-.,,.,v-,.,,,J,,... st...:~,'-<--
1, ' ' v
St!.-SB ,.,
$112-loA , s~,,.J..., r by ,.d,!.;"\,.., (J.0~ ,.__ ~"Y )
-\ l '
..J It.· \.sHJ ~ . '
•comments/Special Instructions:
Page _5__ of __l_ pages
Controlled Documenl -Asbestos coc -R2 -4/9/2013
OrderID: 291603738
Page 4 Of 6
Asbestos Bulk Building Material EMSLANALn1cAL, INc.
2500 GATEWAY CENTRE BLVD, ~---c:-------~Cbain of Custod}! su1TE 500
!antic Shores Environmental Svcs., Ud Order ID: 291-603-73-8---------\LE, NC 27560
• 1272A
EMSL ANAi No Samples: 120 ~·•=m~·'" 6/9/201617:0 TAT: 48 Hour Due: 06/115:00 PM 919-465-3900
------PLM Bulk Fax: 910-371-6652 § I §-465-3§55
Additional Pages of the Chain ot Cusrooy are omy ner.;e:s:sa1y" """u"u ,u, guurnvuv, vu .. ,,-,_····-····-··-_
Sample# HA# Sample Location Material Descrioti on
S"f-1A \Jn '.o~, ~ ~ J SJ..011u'• .:,,--lfuol 3,t,J ... c //,,, ,Al [/\J'v-J~
51!-., ·1'.3 \ '-,..,
3i-1A Se",,...,. i-o...... AG [AJb-') J,4. yty
5"¥?.-713 1, I,
5,2-q /.l l~v,4,.L •A -'"'""' L w-1 l
~ ,
sn-"113 k "'
Si-C/L ''-..,,,
SY.?-1o A Si~/ ,a ~ O"\ fl> Al' 1<J>' l w,-,11
SYl-1of3 "' ' .,
-J'/2.-Ii A 5-lAI,-.,. ~ A,M, ~J r, ,.h l. k),,,-1:..
:312-1113 " I-,
511.-Jl A wh'.k s,"1,.,J--}l\{,r t'-Jc!JLL
1512-n 13 \,,. \: '\. /1
fi'A -I A .5 /... 0 ..,. l'OtJ ....._ .,.) d : r."\. _ E'/1-dc F,
SA -? 13 " t-,
5A-, .1.A (/'-l l.: k FT
5A; ,-13 ,-,,
SA_:lA &,,-.,,, FT
S'A-JfJ ' ,.. 1,
J/1-l/.JI , .... l:,iN /;(__
54-,i-! B ~ ,,
5 A -,i.j,1., IL It
*Comments/Special Instructions:
Page 2_ of ___k__ pages
Controlled Documenl -Asbestos coc-R2 -41912013
OrderID: 291603738
Page 5 Of 6
-------------
•
Asbestos Bulk Building Material EMSLANALYT1cAL, /Ne.
2500 GATEWAY CENTRE BLVD, ~------__ Chain_oJ_Cus_todv ________ ~ su1TE 500
Atlantic Shores Environmental Svcs., Ltd Order ID: 291603738 VILLE, NC 27560
EMSLAI ~
1272A No Samples: 120
Due: 06/11 5.00 PM IE: 919-465-3900 6/9/2016 17:0 TAT: 48 Hour
Bulk PLM Fax: 910.371-6652 .x. § I §-4fla-3§06
Additional Pages of the Chain ot custoay are only necessary IJ flf:lf:jUtJU /UI dUU/llUlfat ;;,a,11,.,,0 1/f/VllrnAuVn
Sample# HA# Sample Location Material Description
At<-I!.\ '3 ~ VW IV 0•"'-AJJ: J '"" Je,.../ '3v,4rc !1 0 "-s:ck t I 't-&r; !
~
1112-13 \ I. '7
A 12-I L VL
,,..,
A12-lA 3 01...,. i-,,J ( () r,ef :J. j, ,d~-
v
AR· .l 8 ,, 1,
A1Q-JA fop4'e, 4,_JJ..,
~' -'1 Ml-; B
4fl-] l ~ ,,
flff2. l\J.l )f.r /T" 1 ~ .. p,r-.
A i2-l\ i} '-'-'r
f:i-5 A fooef.'., ,1"".S"IA i.ti:t-.
All· S iJ ~ v <
At'-5L " ,,
,i,.
~-JA ;'1~ '~J.....,Vnl<.. Ml J N ~-· lr bu/J, tJuJc Pr 1.L<U
• v \ ' .,
~-l J3
Q-J,A &, "''( r:, J,:',,,J).
' R-JB ,~ .,
V.-].A 1,,Vk f, 1L, I .L
(2.-J]3 ,, ,,
12· >lA .... ,.. l-1 v A L. bud-utfk,·,s .s.. to-1",ut •
v £. i;,3 .... ,,
p -t.tL ,v ,,
I'
'Comments/Special Instructions:
Page __L of _k_ pages
Controlled Do~ument-Asbastos CCC -R2 -41912013
OrderID: 291603738
Page 6 Of 6
• Asbestos Bulk Building Material ___ ~EMSLANALYT1cAL, INc.
--\T8NAY CENTRE BLVD,
' A!!antic Shores Environmental Svcs., Ud Order ID: 291603738 SUITE 600 No Samples: 120
1272A Due: 06111 5:00 PM RRISVILLE, NC 27560
!e!, 6'912D1617:0 TAT: 4BHo~:lk Fax: 910-371-6652 'HONE: 919-465-3900 ----LAI: PLM FAX. § I S-4i'l5-3§51'.l
Additional Pages of the Chain of Custody are only necessary if needed for additional sample information
Sample# HA# Sample Location Material Description
t-~A /I>(),.:" L., 111, "-), tP{l~I Bid~ ,2x~ er f~!.5 -4' l.
v
/Z-5 3 ,-.,
fl-5G, ,, 1
R-fu ,4 PW/TC
(2-bij ,, ,,
fZ-~l. 'IV ... It
,Ztz-JA ;11.:., k~."" J, l-1.p14 !,-),/,I, /col fl"'' </:,, (.,, m 1-J.-/Pt!\ J--
v v ,
"1Z.1! -I 13 \' /}
gfl.-2/l ~"' 1-,.,. J:,,_,_ .;,,,,, I«-,'+-
(2£-J.13 " ,,
12.f!-3 A wL.:k S-e,,i,,\4 J.-
[}fl-.113 \c "
/Zll · '-lA )51,., L iL -1,..r v~ .l.,--/2 R.-.J
/W.-<.J J? ~/ \,'. ,,
if1.-1A Auh, bodv Sk,,,, ~ p, .( "'-< th. J.,l.,_ s-l.,_ 1,...,-J-. ' '
BR.-V!3 ,, ,._,
5e-1.A-c;,RIP-I, C:!3 ........... \ ,,,..:!-(._ '" J..t-I"''-' ,,__
)> P. ' )._, I] ''-,,_
i,l-5-A Jvr4,. <<--{.-,,,b rJ L
Be-313, ~, \,-. 'I ,.,
f;-;lA u..,: • .,,:l, [u.rJ .:Sk...,,,.~'"' !,.,1.1\ AdJ:Lm i.-)h.t r-,
15-}t 1> ' .
5-2 l c_ ll/
•comments/Special Instructions:
Page~ of .Ja.__ pages
Controlled Document -Asbestos COC -R2-41912013
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603781EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Attention:Phone:Cheryl Moody (910) 371-5980
Fax:Atlantic Shores Environmental Svcs., Ltd (910) 371-6652
Received Date:154 Backhoe Road 06/10/2016 3:30 PM
Analysis Date:Leland, NC 28451 06/10/2016
Collected Date:
Project:1272 A
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
K-1A
291603781-0001
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
Kia Building - Exterior
Surfacing
K-1B
291603781-0002
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
Kia Building - Exterior
Surfacing
K-1C
291603781-0003
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Kia Building - Exterior
Surfacing
K-2A
291603781-0004
None DetectedNon-fibrous (Other)90%Cellulose10%Gray
Fibrous
Homogeneous
Kia Building - Exterior
Panneling
K-2B
291603781-0005
None DetectedNon-fibrous (Other)92%Cellulose8%Gray
Fibrous
Homogeneous
Kia Building - Exterior
Panneling
K-2C
291603781-0006
None DetectedNon-fibrous (Other)85%Cellulose15%Gray
Fibrous
Homogeneous
Kia Building - Exterior
Panneling
K-3A
291603781-0007
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Kia Building - Window
(exterior) Caulking
K-3B
291603781-0008
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Kia Building - Window
(exterior) Caulking
K-4A-Floor Tile
291603781-0009
None DetectedNon-fibrous (Other)100%Gray/Blue
Non-Fibrous
Homogeneous
Kia Building - Window
(exterior) Caulking
K-4A-Mastic
291603781-0009A
None DetectedNon-fibrous (Other)95%Cellulose
Synthetic
3%
2%
Tan
Fibrous
Homogeneous
Kia Building - Window
(exterior) Caulking
K-4B
291603781-0010
None DetectedNon-fibrous (Other)100%Cellulose<1%Gray/Blue
Non-Fibrous
Homogeneous
Kia Building - 12x12
Light Blue FT
Insufficient amount of mastic for analysis.
K-5A
291603781-0011
None DetectedNon-fibrous (Other)100%Tan/White
Non-Fibrous
Homogeneous
Kia Building - 12x12
Light Blue FT
K-5B
291603781-0012
None DetectedNon-fibrous (Other)93%Cellulose
Synthetic
5%
2%
Tan/White
Fibrous
Homogeneous
Kia Building - 12x12
Light Blue FT
K-5C
291603781-0013
None DetectedNon-fibrous (Other)95%Cellulose
Synthetic
3%
2%
Gray/Tan
Fibrous
Homogeneous
Kia Building -
Backboard Mastic
(original)
K-6A
291603781-0014
None DetectedNon-fibrous (Other)77%Cellulose
Glass
15%
8%
Gray/White
Fibrous
Homogeneous
Kia Building -
Backboard Mastic
(original)
This is a composite result of drywall and jt. compound
Initial Report From: 06/13/2016 13:26:41
Page 1 of 5PLM - 1.69 Printed: 6/13/2016 1:26 PM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603781EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
K-6B
291603781-0015
None DetectedNon-fibrous (Other)82%Cellulose
Glass
Wollastonite
10%
8%
<1%
Gray/White
Fibrous
Homogeneous
Kia Building -
Backboard Mastic
(add on)
This is a composite result of drywall and jt. compound
K-6C
291603781-0016
None DetectedNon-fibrous (Other)80%Cellulose
Glass
15%
5%
White
Fibrous
Homogeneous
Kia Building - DW/JC
original
This is a composite result of drywall, and jt. compound.
K-7A
291603781-0017
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
30%
40%
Gray/White
Fibrous
Homogeneous
Kia Building - DW/JC
original
K-7B
291603781-0018
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
30%
40%
Gray/White
Fibrous
Homogeneous
Kia Building - DW/JC
original
K-7C
291603781-0019
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
Kia Building - 2x2
Powder CT
K-8A
291603781-0020
None DetectedNon-fibrous (Other)85%Cellulose
Glass
Wollastonite
10%
5%
<1%
Gray/White
Fibrous
Homogeneous
Kia Building - 2x2
Powder CT
This is a composite result of drywall and jt. compound
K-8B
291603781-0021
None DetectedNon-fibrous (Other)78%Cellulose
Glass
Wollastonite
15%
5%
2%
Gray/White
Fibrous
Homogeneous
Kia Building - 2x2
Powder CT
This is a composite result of drywall and jt. compound
K-8C
291603781-0022
None DetectedNon-fibrous (Other)80%Cellulose
Glass
Wollastonite
15%
5%
<1%
Brown/White
Fibrous
Homogeneous
Kia Building - DW/JC
Addition
This is a composite result of drywall, and joint compound.
K-9A
291603781-0023
None DetectedNon-fibrous (Other)98%Cellulose2%White
Fibrous
Homogeneous
Kia Building - DW/JC
Addition
K-9B
291603781-0024
None DetectedNon-fibrous (Other)98%Cellulose2%White
Fibrous
Homogeneous
Kia Building - DW/JC
Addition
S-20A
291603781-0025
None DetectedNon-fibrous (Other)10%Cellulose
Min. Wool
Glass
10%
65%
15%
Gray/White
Fibrous
Homogeneous
University Ford
Showroom - HVAC
Sealant
S-20B
291603781-0026
None DetectedNon-fibrous (Other)5%Cellulose
Min. Wool
Glass
15%
65%
15%
Gray/White
Fibrous
Homogeneous
University Ford
Showroom - HVAC
Sealant
S-20C
291603781-0027
None DetectedNon-fibrous (Other)15%Cellulose
Min. Wool
Glass
5%
60%
20%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom - HVAC
Sealant
S-21A
291603781-0028
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
30%
40%
Gray/White
Fibrous
Homogeneous
University Ford
Showroom - Smooth
CT Showroom
S-21B
291603781-0029
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Gray/White
Fibrous
Homogeneous
University Ford
Showroom - Smooth
CT Showroom
S-21C
291603781-0030
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
University Ford
Showroom - Smooth
CT Showroom
R-7A
291603781-0031
None DetectedPerlite
Non-fibrous (Other)
5%
72%
Cellulose
Glass
15%
8%
Tan/White
Fibrous
Homogeneous
Maintenance & Repair
Building - Pitted CT
Showroom
Initial Report From: 06/13/2016 13:26:41
Page 2 of 5PLM - 1.69 Printed: 6/13/2016 1:26 PM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603781EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
R-7B
291603781-0032
None DetectedPerlite
Non-fibrous (Other)
5%
72%
Cellulose
Glass
15%
8%
Tan/White
Fibrous
Homogeneous
Maintenance & Repair
Building - Pitted CT
Showroom
R-7C
291603781-0033
None DetectedNon-fibrous (Other)75%Cellulose
Glass
20%
5%
Brown/White
Fibrous
Homogeneous
Maintenance & Repair
Building - Pitted CT
Showroom
R-8A
291603781-0034
None DetectedNon-fibrous (Other)95%Cellulose5%Gray
Fibrous
Homogeneous
Maintenance & Repair
Building - CT 2x2 in
drive thru
R-8B
291603781-0035
None DetectedNon-fibrous (Other)98%Cellulose2%Gray
Fibrous
Homogeneous
Maintenance & Repair
Building - CT 2x2 in
drive thru
R-9A
291603781-0036
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
30%
40%
Tan/White
Fibrous
Homogeneous
Maintenance & Repair
Building - CT 2x2 in
drive thru
R-9B
291603781-0037
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
30%
40%
Tan/White
Fibrous
Homogeneous
Maintenance & Repair
Building - HVAC
Sealant Upstairs
R-9C
291603781-0038
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
Maintenance & Repair
Building - HVAC
Sealant Upstairs
R-10A
291603781-0039
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
15%
55%
Gray/Black
Fibrous
Homogeneous
Maintenance & Repair
Building - CT
Bathroom 2x2
R-10B
291603781-0040
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
15%
55%
Gray/Black
Fibrous
Homogeneous
Maintenance & Repair
Building - CT
Lockeroom 2x2
R-10C
291603781-0041
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/Gray
Fibrous
Homogeneous
Maintenance & Repair
Building - CT Storage
Room 2x4
R-11A-Floor Tile
291603781-0042
2% ChrysotileNon-fibrous (Other)96%Cellulose2%Gray/White
Fibrous
Homogeneous
Maintenance & Repair
Building - Locker FT
w/ Mastic
R-11A-Mastic
291603781-0042A
3% ChrysotileNon-fibrous (Other)97%Tan/Black
Fibrous
Homogeneous
Maintenance & Repair
Building - Locker FT
w/ Mastic
R-11B-Floor Tile
291603781-0043
Positive Stop (Not Analyzed)Maintenance & Repair
Building - Locker FT
w/ Mastic
R-11B-Mastic
291603781-0043A
Positive Stop (Not Analyzed)Maintenance & Repair
Building - Locker FT
w/ Mastic
R-12A
291603781-0044
None DetectedNon-fibrous (Other)98%Cellulose2%Gray/White
Fibrous
Homogeneous
Maintenance & Repair
Building - North Shop
Door Sealant
R-12B
291603781-0045
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Maintenance & Repair
Building - North Shop
Door Sealant
R-13A
291603781-0046
8% ChrysotileNon-fibrous (Other)84%Cellulose
Min. Wool
3%
5%
Gray/Black
Fibrous
Homogeneous
Maintenance & Repair
Building - Sealant b/w
Metal C-Block
R-13B
291603781-0047
Positive Stop (Not Analyzed)Maintenance & Repair
Building - Sealant b/w
Metal C-Block
R-14A
291603781-0048
3% ChrysotileNon-fibrous (Other)95%Cellulose2%Gray/White
Fibrous
Homogeneous
Maintenance & Repair
Building - C-Block
Interior Corner
Sealant
Initial Report From: 06/13/2016 13:26:41
Page 3 of 5PLM - 1.69 Printed: 6/13/2016 1:26 PM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603781EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
R-14B
291603781-0049
Positive Stop (Not Analyzed)Maintenance & Repair
Building - C-Block
Interior Corner
Sealant
R-15A
291603781-0050
None DetectedNon-fibrous (Other)98%Cellulose2%White
Fibrous
Homogeneous
Maintenance & Repair
Building - Drive Thru
Door Window Glazing
R-15B
291603781-0051
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Maintenance & Repair
Building - Drive Thru
Door Window Glazing
R-16A
291603781-0052
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
Maintenance & Repair
Building - Caulking by
R-15
R-16B
291603781-0053
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
Maintenance & Repair
Building - Caulking by
R-15
B-1
291603781-0054
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
Auto Body Shop
Building - North Door
Exterior Sealant
B-2A
291603781-0055
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
Auto Body Shop
Building - CT 2x4
E-Room
B-2B
291603781-0056
None DetectedPerlite
Non-fibrous (Other)
20%
10%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
Auto Body Shop
Building - CT 2x4
E-Room
B-2C
291603781-0057
None DetectedPerlite
Non-fibrous (Other)
15%
15%
Cellulose
Min. Wool
30%
40%
Brown/White
Fibrous
Homogeneous
Auto Body Shop
Building - CT 2x4
E-Room
B-3A
291603781-0058
None DetectedNon-fibrous (Other)77%Cellulose
Glass
15%
8%
Gray/White
Fibrous
Homogeneous
Auto Body Shop
Building - DW/JC E-
& Office
This is a composite result of drywall and jt. compound
B-3B
291603781-0059
None DetectedNon-fibrous (Other)80%Cellulose
Glass
Wollastonite
15%
5%
<1%
Gray/White
Fibrous
Homogeneous
Auto Body Shop
Building - DW/JC E-
& Office
This is a composite result of drywall and jt. compound
B-3C
291603781-0060
None DetectedNon-fibrous (Other)75%Cellulose
Glass
Wollastonite
20%
5%
<1%
Brown/White
Fibrous
Homogeneous
Auto Body Shop
Building - DW/JC E-
& Office
This is a composite result of drywall, and jt. compound.
B-4A
291603781-0061
None DetectedNon-fibrous (Other)98%Cellulose2%Gray/White
Fibrous
Homogeneous
Auto Body Shop
Building - Bathroom
Sink Sealant
B-4B
291603781-0062
None DetectedNon-fibrous (Other)98%Cellulose2%Gray/White
Fibrous
Homogeneous
Auto Body Shop
Building - Bathroom
Sink Sealant
B-5A-Floor Tile
291603781-0063
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Auto Body Shop
Building - 12x12 FT
w/ Mastic
B-5A-Mastic
291603781-0063A
None DetectedNon-fibrous (Other)98%Cellulose2%Tan
Fibrous
Homogeneous
Auto Body Shop
Building - 12x12 FT
w/ Mastic
B-5B-Floor Tile
291603781-0064
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
Auto Body Shop
Building - 12x12 FT
w/ Mastic
B-5B-Mastic
291603781-0064A
None DetectedNon-fibrous (Other)98%Cellulose2%Tan
Fibrous
Homogeneous
Auto Body Shop
Building - 12x12 FT
w/ Mastic
Initial Report From: 06/13/2016 13:26:41
Page 4 of 5PLM - 1.69 Printed: 6/13/2016 1:26 PM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291603781EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
B-6A
291603781-0065
None DetectedNon-fibrous (Other)97%Cellulose3%Tan
Fibrous
Homogeneous
Auto Body Shop
Building - Backboard
Mastic Office
B-6B
291603781-0066
None DetectedNon-fibrous (Other)90%Cellulose10%Tan
Fibrous
Homogeneous
Auto Body Shop
Building - Backboard
Mastic Office
B-7A
291603781-0067
2% ChrysotileNon-fibrous (Other)94%Cellulose
Wollastonite
2%
2%
Gray
Fibrous
Homogeneous
Auto Body Shop
Building - South Door
Interior Sealant
B-7B
291603781-0068
Positive Stop (Not Analyzed)Auto Body Shop
Building - South Door
Interior Sealant
Analyst(s)
Joshua Moorman (24)
Kelly Gallisdorfer (44)
Essie Spencer, Laboratory Manager
or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no
responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim
product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL
recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless
requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Morrisville, NC NVLAP Lab Code 200671-0, VA 3333 000278, WVA LT000296
Initial Report From: 06/13/2016 13:26:41
Page 5 of 5PLM - 1.69 Printed: 6/13/2016 1:26 PM
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600, Morrisville, NC 27560
Phone/Fax:(919) 465-3900 / (919) 465-3950
http://www.EMSL.com raleighlab@emsl.com
291603781
CustomerID:ATLS78
CustomerPO:
ProjectID:
EMSL Order:
Attn:Cheryl Moody
Atlantic Shores Environmental Svcs., Ltd
154 Backhoe Road
Leland, NC 28451
Received: 06/10/16 3:30 PM
1272 A
Fax:(910) 371-6652
Phone:(910) 371-5980
Project:
6/23/2016Analysis Date:
Collected:
SAMPLE ID APPEARANCE
NON- ASBESTOS
% NON-FIBROUS
(%) Matrix
Organic Acid
ASBESTOS
% TYPESDESCRIPTION
NON- ASBESTOS
% Fibrous
Test Report: Polarized Light Microscopy (PLM) - Point Count Performed by EPA 600/R-
93/116 Method with Gravimetric Reduction and 400 Point Count
R-11A-Floor Tile
291603781-0042
Gray/White 22.2Maintenance &
Repair Building -
Locker FT w/
Mastic
Fibrous
Homogeneous
36.3 Chrysotile3.2Non-fibrous (other)38.3
R-11A-Mastic
291603781-0042A
Tan/Black 39.4Maintenance &
Repair Building -
Locker FT w/
Mastic
Fibrous
Homogeneous
52.3 Chrysotile0.5Non-fibrous (other)7.8
R-11B-Floor Tile
291603781-0043
Positive Stop (Not Analyzed)
Maintenance &
Repair Building -
Locker FT w/
Mastic
Positive Stop (Not Analyzed)
R-11B-Mastic
291603781-0043A
43.4Maintenance &
Repair Building -
Locker FT w/
Mastic
Fibrous
Homogeneous
37.4 Chrysotile3.9Non-fibrous (other)15.3
R-14A
291603781-0048
Gray/White 14.1Maintenance &
Repair Building -
C-Block Interior
Corner Sealant
Fibrous
Homogeneous
37.0 Chrysotile4.9Non-fibrous (other)44.0
R-14B
291603781-0049
Positive Stop (Not Analyzed)
Maintenance &
Repair Building -
C-Block Interior
Corner Sealant
Positive Stop (Not Analyzed)
Billy Barnes, Asbestos Lab Manager
or other approved signatory
Test Report PLMPCGrav-7.26.0 Printed: 6/23/2016 10:42:48 AM 1
Analyst(s)
Disclaimers: Some samples may contain asbestos fibers present in dimensions below PLM resolution limits. The limit of detection as stated in the method is 0.25%. EMSL Analytical Inc. suggests that samples reported as <0.25% or none detected undergo additional analysis via TEM. The above test report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical Inc.. This report must not be used to claim product endorsement by NVLAP or any agency of the United States Government. EMSL Analytical Inc. bears no responsibility for sample collection activities, analytical method limitations, or the accuracy of results whin requested to separate layer samples. EMSL Analytical Inc. liability is limited to the cost of sample analysis. The test results contained within this report meet the requirements of NELAC unless otherwise noted. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Morrisville, NC NVLAP Lab Code 200671-0, VA 3333 000278, WVA LT000296
Joshua Moorman (4)
Olivia Bradley (2)
Initial report from 06/22/2016 16:43:59
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600, Morrisville, NC 27560
Phone/Fax:(919) 465-3900 / (919) 465-3950
http://www.EMSL.com raleighlab@emsl.com
291603781
CustomerID:ATLS78
CustomerPO:
ProjectID:
EMSL Order:
Attn:Cheryl Moody
Atlantic Shores Environmental Svcs., Ltd
154 Backhoe Road
Leland, NC 28451
Received: 06/10/16 3:30 PM
1272 A
Fax:(910) 371-6652
Phone:(910) 371-5980
Project:
6/23/2016Analysis Date:
Collected:
SAMPLE ID APPEARANCE
NON- ASBESTOS
% NON-FIBROUS
(%) Matrix
Organic Acid
ASBESTOS
% TYPESDESCRIPTION
NON- ASBESTOS
% Fibrous
Test Report: Polarized Light Microscopy (PLM) - Point Count Performed by EPA 600/R-
93/116 Method with Gravimetric Reduction and 400 Point Count
B-7A
291603781-0067
Tan 32.3Auto Body Shop
Building - South
Door Interior
Sealant
Fibrous
Homogeneous
29.9 Chrysotile0.9Non-fibrous (other)36.9
B-7B
291603781-0068
Tan 31.8Auto Body Shop
Building - South
Door Interior
Sealant
Fibrous
Homogeneous
21.5 Chrysotile2.2Non-fibrous (other)44.5
Billy Barnes, Asbestos Lab Manager
or other approved signatory
Test Report PLMPCGrav-7.26.0 Printed: 6/23/2016 10:42:48 AM 2
Analyst(s)
THIS IS THE LAST PAGE OF THE REPORT.
Disclaimers: Some samples may contain asbestos fibers present in dimensions below PLM resolution limits. The limit of detection as stated in the method is 0.25%. EMSL Analytical Inc. suggests that samples reported as <0.25% or none detected undergo additional analysis via TEM. The above test report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical Inc.. This report must not be used to claim product endorsement by NVLAP or any agency of the United States Government. EMSL Analytical Inc. bears no responsibility for sample collection activities, analytical method limitations, or the accuracy of results whin requested to separate layer samples. EMSL Analytical Inc. liability is limited to the cost of sample analysis. The test results contained within this report meet the requirements of NELAC unless otherwise noted. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Morrisville, NC NVLAP Lab Code 200671-0, VA 3333 000278, WVA LT000296
Joshua Moorman (4)
Olivia Bradley (2)
Initial report from 06/22/2016 16:43:59
OrderID: 291603781
Page 1 Of 4
•
Asbestos Bulk Building Material
Atlantic Shores Environmental Svcs .. Ltd Order ID: 291603781
1272 A No Samples: 68
EMSLANALv· 6/10/201615:30 TAT: 24Hour Due: 06/113.00PM
EMSL ANALYTICAL lt.C
"f:_\/'/AY CFNTR:=
ID. SUITE 6JJ
E. NC 2750C
'-ABOll,•:ro ...... ~1100, PLM Bulk Fax: 910-371,6652 19 J 465-3900
--• ,v, ,d19) 465-3950
I I I , · ~ , I EMSL-Bill to: L.JSame D Different Company: ,'-I IH'\4' L 0 V\CJf~ (: viV ·~ 1.M......H'-<.l ~-\, l t) i If Bill to 1s Different note instructions in Comments··
Street: i c;· ~ CS:. L 'lk l ti J --------[ Third Partv 811/1nn renu1res written authonzation from third oartv
City: (, ,·~-r ~le/Province: /\_;L I Zip/Postal Code: -~uritry:______ _
Renert To /Name\: c_lu,, \ /•ice•! _ Telephone#:
I Email Address: (.Lici.,1'/ (£_• (,L~ . .:C.ls.1..,~1<~-(-j,tV (e,,V"L --Fax#:-::=="-----------r~~~r~------
Project Name/Number: /1 'l l ,6_ _ -------PlemP;:;;;;-;;~~ 0 Fax O Email ------
U.S. State Samoles Taken: JJ I -----CT Samoles: 0 Commercial/Taxable D Residential/Tax Exempt
,.--Turnaround Time IT A Tl Ootions• -Please Check
D 3 Hour I D 6 Hour I ''"" 24 Hour I D 48 Hour I D 72 Hour I D 96 Hour I O 1 Week I D 2 Week
"For TEM Air 3 hr through 6 hr, please call ahead to schedule. •rhere is a premium charge for 3 Hour TEM AHERA or EPA Level fl TAT You will be asked to sign
an authorization form for this service. Ana/vsis comr.leted in accordance with EMSL 's Terms and Conditions located in the Ana/vfica! Price Guide.
,, PLM -Bulk (reporting limit) _ , TEM -Bulk _
@1fLM EPA 600/R-93/116 (<1%) 0 TEM EPA NOB-EPA 600/R-93/116 Section 2.5.51---
O PLM EPA NOB (<1 %) 0 NY ELAP Method 198-4 (TEM)
Point Count D 400 (<0.25%) D 1000 (<0.1 %) D Chatfield Protocol (semi-quantitative)
Point Count w/Gravimetric D 400 (<O 25%) D 1000 (<0.1 %) D TEM % by Mass -EPA 600/R-93/116 Section 2.5.5.2
D NIOSH 9002 (<1%) D TEM Qualitative via Filtration Prep Technique
D NY ELAP Method 198.1 (friable ,n NY) 0 TEM Qualitative via Drop Mount Prep Tec_hnique ___ _
O NY ELAP Method 198.6 NOB (non-friable-NY) ____ _ Other ____ _
O OSHA ID-191 Modified
D Standard Add1t1on Method 0
~eek For Positive Stoa -Clea riv ldentifv Homoaenous Grouo I Date Samoled:
Samplers Name: tJ! t L S0l,· , I Samplers Signature: k#Y-
'
Sample# HA# Sam nle Location
)(-iil t,\. !:-
I (--,k c " Z5"c,
Jc.-JB I I
-x. -) (._ I I ,\
t )Ji
1 ,.,
/....-I
v li 'L I ll
'tr-)l 1-I
k > a ~ -'::> _A--j )
t·
Material Descriotion ,,
S'v4i'"-' ·~l-•\
·,.; 1,
/1
-J ;,
!,
/c-6' p J l'-It J
JI'.-!_JA L/
)l ~g L/ \I I
, Client Sample# (s): ---~k~ c.1_71_-__ 157 -'> Total# of Samples: Gr
Relinquished (Client): Date: Time:
Received (Lab): . L---' Date: (, I J --, I ,, ,---,
Time: Sn -
Comments/Special Instructions: -'
Controlled Document -Asbes1os COC -R2 -41912013
Page 1 of __j__ pages
I
OrderID: 291603781
Page 2 Of 4
A!':h~!':tos Bulk Buildina Material EMSL ANALYTICAi .. INC
-ENTRE BL';O
SUITE 6GJ
E:MSL ANALYT
LABORATOFfY•PROCU
Atlantic Shores Environmental Svcs., Ltd
1272A
6/10/2016 15 30
PLM
TAT: 24 Hour
Bulk
OrderlD: 291603781
No Samples: 68
Due: 06/11 3:00 PM
Fax: 91Cl-371-6652
., NC 27S6C,
9-465-3S);}J
Additional Pages of the Chain of Custody are only necessary if needed for additional sample information
Sample# HA# Sample Location Material Descriotion
}(.-·i A r ~ •'-
-,. \~:,c, ti· tb .-i \a:.\....,) be .. l ~LI..,'-J\.,1<....\ f-'(._
j I
)l. 'j 13 ) \'-!;
k '5 C.. ) \ '-ll c ,, A, c \
I: -le A C-l)LJ /:f L r~;J \ ,\t,-{
'-' )('. -lt 1$ (_, ,, "
K-1,c L-h 1,
i(-1 /:, ' )..x )_ pc, .. ~ (T . t-11> "] k "
Ii. -1 (_ ' k ;,
/l [A q I) ~0 / YL. .A Jd. \ ·~ ,, (, IL·!'> (>
JC YL y I, I,
):. <J _,4 a MV I+ (_, 5{af,,~~
~ -') 13 1 I l,, !;
5-)oA b Un,VJ,:;, l 1 f. ·f ,C. 5h£\.-J /t:t:'•:A. 5 ,"1 :c .I k (T s M.-t. ~-.l't..'lv\.'\.._
5 )NS 2(} " 1,
5 /e,1 ( '7f~I
•\ '/
S-J/ ,~ " I v ,: )-.i--,) Cr 3 hcv·vi(1;:.1 ~"'\.
5 )_/ 1> 2-1 \\ I,
s ).\ (_ • I ,. ,, u/ ' g-7A '?._-:-] iVi,,,-.,, ~..,.,,,,_ + ,?.,-i . .';-t <)' /.!. l., (f ).1 ,~1. ' c:I t V; ~ \..AJ I.,"\.
/Z-7 5 (1_, 7 ~ (~ ,,
/?.. 7 ( r-1 \ ,/ 1~ .,_
*Comments/Special Instructions:
1 i Page~-of~-pages
Controlled Document -Asbestos COC -R2 -4.'0.'20 1 J
OrderID: 291603781
Page 3 Of 4
Asbestos Bulk Building Material EMSL ANALYTICAL. INC
,;r::nr-. r.;ATEWAY CENTRE 8L1JO
SUITE 6DC
)RRISVILLE. NC 27Ssc,
Atlantic Shores Environmental Svcs., Ltd
1272 A
' 6110/20161530 TAT: 24 Hour
PLM Bulk
Order ID: 291603781
No Samples: 68
Due: 06/11 3:00 PM
Fax: 910-371-6652 PHONE 919-465-390J
FAX. 9 I 9-4(:L~:-J::i~,~·
Additional Pages of the Chain of Custody are only necessary if needed for additional sample information
Sample# HA# Sample Location Material Descriotion
f fit f?.--'t A I,, : '\ k.,...,LU .1 ,1, I,\\,., l-/ L!A (__ _S'tc, \,"'-\-t \ ' ,., ~<, \,,. (.-::,o..r -~
t-'f \:S (?_ 5 j .,,
r',
,o .), ' '"'---Jxl ll-C\ .A R,_ 'i (, ls',: ~I,,·"'''"" -,,1,
r '\ 15 f •' I 1, /)
{2-'] {____ /2 'f 1, It
)Z-iv ,4 /(_ -/0 /T LtJ Lt ...,~rot1 J-""\. J,...j e-lo i) f-tv \\ 1,
(2-\o L l'lf<.J LT <-_;J,,1-.-..__, it,(. ...... ~-.J . f JIA I I I i<.· (_ l(. • f'A.,, 1A,_ j:T V'2/1 v\1· ·,; L
(!.110 fl; I l~ I/
)? I! A /2fl--))Ln th '3 hz.,"" J,cr ;5,e ,,Iµ ,,,j
'{'. 11 ~ I • f'r l 1-~
£-15 ·\ /2;3 5, .. lvi \ 6_;,;." ,IM 1-,.( ,, c -b 1,i/C
P.-l>l';, /)_/ ':, 1, ,,
fH A (LI'-/ (-}1i0t.k · ... ,l-(,.:c:J-(,_,,,c,r ~ ,~ l,., ~
J2H / 3,. J?-1'1/ ,,, '1
£-ic; 4 f;J Dr ivt. +iN J,,<-r c\J .',J,;,..,-\ i<.u "'-,
v
12-is-13 r2 )J
, '-~ '7
i,2-/ I; ,_'./ /!.! (, (,, ul le "'~ I=, x-is-
/-/(, J I 11 {?-lk;)) \ I \\
)5 -I &! /l,)1 J,,c!y s;i.-,., ~0-A-\ Ale: ~Le Jui--n.k ,/' Se~·-fa\A. +
8 J-A ' __.,
f!,L {T ) , '-l </ )C"'U •""--
B-;_ 13 f, 2 ,l ,,,
l) 1.C f,L \ J "" ,j
.. Comments/Special Instructions:
Page _3___ of _j__ pages
Controlled Document -Asbestos COC -R2 -419.'20 1 3
OrderID: 291603781
Page 4 Of 4
• EMSL ANALYTIC/.
CA9QJIATOflV•POIOtlV(:T$•
Asbestos Bulk Building Material
Atlantic Shores Environmental Svcs., Ltd
1272 A
6/10/20161530
PLM
TAT: 24 Hour
Bulk
Order ID: 291603781
No Samples: 68
Due: 06111 3 00 PM
Fax: 910-371-6652
EMSL ANALYTICAL. INC
?t;()() GATf=\~,/4Y r.i::NTRE BL\/[)
SU!TE 6C:,'~,
JC 27Sf:=iC
Additional Pages of the Chain of Custody are only necessary 1f needed for additional sample information
Sample# HA# Sample Location Material Description
lJ > ,1\ ~-_s Ac. 1.c &-"', 3[.,, . ., !Sc J),--.J / J L ,{ -w..., }, p • (•'-!-l l
J
Jf ,-:;B ~-3 [\ I '
,'-i-5 C e-3 I\ I/
l3-1,1/\ Cs -Y B., ri,,,-:~ ,,, j: :;,,~~-r
!3'·4J (3 i.j I\ /}
$-'i A IP, J-/2 x I l FT ,,/,-,1,s)'' L
Ii'..-s l3 ig (' C\ I;
/} (;,AC & l. t.1l t6c_,,J ,&!,,:,./,(_ A I l.{ t·-
13 ~ ,::, f3 (., ,, ' /,
ff 7A £ 1 -I :5.,_,-Jl, D,:cJc ,;,,k.,.cr S-,-i«--1 ~
g-13 8-7 " 'I "
"'Comments/Special Instructions:
Page __1____ of_"\ __ pages
Ct:mlrollra Document -Asbestos C::'.lC -R2 -4/9:20 T 3.
EMSL Analytical, Inc.
2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560
Tel/Fax: (919) 465-3900 / (919) 465-3950
http://www.EMSL.com / raleighlab@emsl.com
291604081EMSL Order:
Customer ID:ATLS78
Customer PO:
Project ID:
Attention:Phone:Cheryl Moody (910) 371-5980
Fax:Atlantic Shores Environmental Svcs., Ltd (910) 371-6652
Received Date:154 Backhoe Road 06/23/2016 10:00 AM
Analysis Date:Leland, NC 28451 06/23/2016
Collected Date:06/19/2016
Project:1272A
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
R-3C
291604081-0001
3% ChrysotileNon-fibrous (Other)95%Cellulose2%Black/Yellow
Fibrous
Heterogeneous
Maintenance and
Repair Bldg - 12x12
Tile w/ Mastic
Analyst(s)
Olivia Bradley (1)Billy Barnes, Asbestos Lab Manager
or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no
responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim
product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL
recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless
requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Morrisville, NC NVLAP Lab Code 200671-0, VA 3333 000278, WVA LT000296
Initial Report From: 06/23/2016 11:57:49
Page 1 of 1PLM - 1.69 Printed: 6/23/2016 11:57 AM
OrderID: 291604081
Page 1 Of 1
EMSL Analytical, Inc.
~~cShores Environmental Sv~ .• Ud ·------·-~rde~.1~/~1:~-;1--:.-.l 2500 Gateway Centre Bouleva --------
eM<
6/23/2016 10:0
PLM
I
TAT: 24Hour
Bulk
No Samples: 1
Due: 06/2410.00 AM
Fax: 910-371-6652
~. NC 27560
•19-465-3900
119-465-3950
Comnanv: Atlantic Shores Environmental Svcs., Ltd EMSL-Bill to: 0 Same D Different
If 8111 to Is Different note instructions in Comments••
Street: 154 Backhoe Road Third Part.v Bil/inn requires written authorization from third nartv
Citv: Leland I State/Province: NC Zin/Postal Code: 28451 l Count=: US
Report To INamel: Elliot Swain Telephone#: 910-371-5980
Email Address: eswain@atlanticshoresenv.com Fax#: 910-371-6652 I Purchase Order:
Pro;ect Name/Number: 1272A Please Provide Results: I IF ax I v' Email I Mail
U.S. State Samnles Taken: NC CT Samples: D Commercialffaxable D Residential/Tax Exemot
_ Turnaround Time (TAT) Options* -Please Check
D 3 Hour I D 6 Hour I ,..., 24 Hour ID 48 Hour I D 72 Hour 10 96 Hour ID 1 Week IO 2Week
*For TEM Air 3 hr through 6 hr, please call ahead to schedule. *There is a premium charge for 3 Hour TEM AHERA or EPA Level II TAT. You will be asked to sign
an authorizatwn form for this service. Analvsis comoleted in accordance with EMSL 's Terms and Conditions located in the Analvlica/ Price Guide.
PLM ~ Bulk {reBorting limit} TEM-Bulk
M EPA 600/R-93/116 (<1%) O TEM EPA NOB -EPA 600/R-93/116 Section 2.5.5.1 -----------------------
0PLM_EJ'_II_NOB(<1%) ·--·---------___________ . 0 NY ELAP Method 198.4 (TEM) ---------------·· ·--Point Count D 400 (<0.25%) D 1000 (<0.1%) D Chatfield Protocol (semi-quantitative)
~0nt Count w/S,ravimetric O 400 (<0.25°/,U;=l _1 O_C!2_l<9.1 %)__ 0 _TEl-1~_by ~ass -EPA 600/R-93/116 Section 2.~.5.2
_ 0 NIOSH~(<1%) _ -------------__ D TEM Qualitat.i?e via Filtration Prep Technique _ --------O NY ELAP Method 198.1 (friable in NY) D TEM Qualitative via Drop Mount Prep Technique
O NY ELAP Method 198.6 NOB (non-friable-NY) Other
O OSHA ID-191 Modified --D ---------------------------D Standard Addition Method
~ck For Positive Stoo -Clearlv Jdentifv Homogenous Group J Date Sampled: 1u/!1/1,
Sampler~ Name:[J/.~iSv->•·i,... /{1-uy I )),4 I ~amplers-~ignature: ~~ --------
Sample# HA# Sample Location Material Descriotion
rt-3L 3 )l11).,,./,111an1.<-tmJ If A \f-t.?u:IJ~ ?}_;( ll.. J·4 w/.11.~~'L.
~
Client Sample# Isl: E-f~/ -Total# of Sam oles: I
Relinquished (Client): // _,.,,/A----Date: ,:; /, t,;JJ L, Time: )l .'r'
Received (Lab):'\?..t\ ~ ~ /
Time: I 0<=-1'Y\ Date: In-'Z 1 -\ k,
Comments/Special Instructions: J\J;-~ 11. ({ d Mt•:> t:1 frt1M i-1-1. f(J/ 5A""i'" i-J fit V)v~\;,' S., h,."· H-< ) •
Page 1 of _I_ pages E r'.:. ~ c-f
fC(S-( ~ ( ~q
Report of Asbestos Survey July 26, 2016
601 Willard Street and 600 Julian Car Street
Durham, North Carolina
ASE Project No. 1272A
1
Photograph 1 – HVAC duct sealant
Photograph 2 –HVAC duct sealant
Report of Asbestos Survey July 26, 2016
601 Willard Street and 600 Julian Car Street
Durham, North Carolina
ASE Project No. 1272A
2
Photograph 3 – Maintenance & Repair building locker room tile and mastic
Photograph 4 – Maintenance & repair building. Sealant between metal and cinderblock.
Report of Asbestos Survey July 26, 2016
601 Willard Street and 600 Julian Car Street
Durham, North Carolina
ASE Project No. 1272A
3
Photograph 5 – Auto body shop roofing sealant on fume hoods.
Photograph 6 – Auto body shop roofing sealant on fume hoods.
Report of Asbestos Survey July 26, 2016
601 Willard Street and 600 Julian Car Street
Durham, North Carolina
ASE Project No. 1272A
4
Photograph 7 – Auto body shop roofing sealant on fume hoods close-up.
Photograph 8 – Brown penetration sealant on auto body building (See Photo 12).
Report of Asbestos Survey July 26, 2016
601 Willard Street and 600 Julian Car Street
Durham, North Carolina
ASE Project No. 1272A
5
Photograph 9 – Mastic in Parts Department located in Maintenance and Repair building
Photograph 10 – Interior cinder block corner sealant in Maintenance and Repair building.
Report of Asbestos Survey July 26, 2016
601 Willard Street and 600 Julian Car Street
Durham, North Carolina
ASE Project No. 1272A
6
Photograph 11 – Auto body building south door cinder block corner sealant.
Photograph 12 – Roof sealant on auto body building
SAMPLE ID PHOTOGRAPH
NO.DESCRIPTION APPEARANCE ASBESTOS
% TYPES CONDITION APPROXIMATE
QUANTITY*
R-3B-Mastic Maintenance & Repair Building - White FT 12x12 mastic - Parts
Dept.Black/Yellow <1% Chrysotile
R-3C Maintenance & Repair Building - White FT 12x12 mastic - Parts
Dept.Black/Yellow 3% Chrysotile
R-4A Maintenance & Repair Building - HVAC Duct Upstairs Storage Gray/White 25%
R-4B Maintenance & Repair Building - HVAC Duct Upstairs Storage Gray/White Positive Stop (Not Analyzed)
R-4C Maintenance & Repair Building - HVAC Duct Upstairs Storage Gray/White Positive Stop (Not Analyzed)
R-11A-Floor Tile Maintenance & Repair Building - Locker FT w/ Mastic Gray/White 3.2% Chrysotile
R-11A-Mastic Maintenance & Repair Building - Locker FT w/ Mastic Tan/Black 0.5% Chrysotile
R-11B-Floor Tile Maintenance & Repair Building - Locker FT w/ Mastic Gray/White Positive Stop (Not Analyzed)
R-11B-Mastic Maintenance & Repair Building- Locker mastic Fibrous 3.9% Chrysotile
R-13A Maintenance & Repair Building - Sealand b/w Metal C-Block Gray/Black 8% Chrysotile
R-13B Maintenance & Repair Building - Sealand b/w Metal C-Block Gray/Black Positive Stop (Not Analyzed)
R-14A Maintenance & Repair Building- C-Block Interior corner sealant Gray/White 4.9% Chrysotile
R-14B Maintenance & Repair Building- C-Block Interior corner sealant Gray/White Positive Stop (Not Analyzed)
B-7A Auto Body Shop Building - South Door Interior Sealant Tan 0.9% Chrysotile
B-7B Auto Body Shop Building - South Door Interior Sealant Tan 2.2% Chrysotile
BR-1A Auto Body Shop Roof - Penetration Sealant - Fume Hoods Gray/White/Black 15% Chrysotile
BR-1B Auto Body Shop Roof - Penetration Sealant - Fume Hoods Gray/White/Black Positive Stop (Not Analyzed)
BR-2A Auto Body Shop Roof - Roof Sealant (Brown with outer layer)Brown/White/Silver 5% Chrysotile
BR-2B Auto Body Shop Roof - Roof Sealant (Brown with outer layer)Brown/White/Silver Positive Stop (Not Analyzed)
Non Friable
100 square- feet
1,100 square -
feet
Table 1. Positive Asbestos Results
1 and 2
9
3
4
10
11
5, 6 and 7
8
Non Friable
Friable
Non Friable
Non Friable
Non Friable
Non Friable 20 linear feet
20 linear feet
1,520 square-
feet
7 linear feet
270 square-feet
100 linear feet
Non Friable
feet
meters
1000
400
FIGURE 1: ASBESTOS LOCATION MAP NApproximate Scale: Not to Scale
Source: Google Earth 2013 Aerial Photograph
ASE Project No. 1272A
July 2016
University Ford Showroom/Office Space
University Kia Showroom/Office Space
Maintenance and Repair Building
Paint and Body Building
Asbestos Survey
601 Willard and 600 Julian Carr Street
Durham, Durham County, North Carolina
Duct wrap
(mezzanine)
Roof sealant - in rows on roof
and around sky lights
Corner sealant (typ)
Corner sealant (typ)
Roof penetration sealant (fume
hoods and vents)
Tile and/or mastic