Loading...
HomeMy WebLinkAbout2601_AnnStreetMSWLFPhase3OperatingCapacityModification_DIN26572_20160803 5400 Glenwood Ave, Suite 400 Raleigh, North Carolina 27612 tel: 919 325-3500 fax: 919 781-5730 August 3, 2016 Mr. Ming-Tai Chao Environmental Engineer North Carolina Department of Environmental Quality Division of Waste Management – Solid Waste Section Raleigh Central Office 1646 Mail Service Center Raleigh, North Carolina 27699-1646 Subject: Cumberland County, North Carolina Subtitle D Landfill – Phase III Operating Capacity Modification Permit No. 2601-MSWLF-1997 Dear Mr. Chao: CDM Smith Inc. (CDM Smith), on behalf of Cumberland County (County), is requesting a modification of the operating capacity of Phase III. In a letter dated May 10, 2016, the Solid Waste Section (SWS) approved a slope of 3.5:1 (horizontal:vertical) along the eastern slope of the landfill and increased the gross capacity of Phases I-III to 4,157,653 cubic yards (CY). The County intends to place additional waste along the eastern slope so that a uniform slope of 3.5:1 is achieved. A Civil 3D analysis estimates that approximately 57,000 cubic yards (CY) of additional material will be placed along the eastern slope in order to provide a constant slope for construction of the final cover system. Increasing the eastern slope to 3.5:1 increases the plateau area of Phase III by approximately 90,000 CY. As stated in the Phase III Interim Closure Modification request dated April 22, 2016, once an elevation of 210 is reached the slope will transition back to 4:1 consistent with the landfill final cover system presented in the Phase IV Permit to Construct Application. The additional volume increases the currently permitted total gross capacity of 6,682,400 by 0.9%. This represents the increase from the gross capacity approved by the SWS on May 10, 2016. A revised grading plan and cross-section are attached and a revised version of Table 1-4 from the Phase IV Permit to Construct Application is presented in Table 1. Mr. Ming-Tai Chao August 3, 2016 Page 2 Table 1. Subtitle D Landfill Phase Capacity and Operational Life Phase Area (acres) Gross Airspace (cy) Total Usable Airspace (cy) Operating Life (years) Remaining I-III (Current) 42.0 4,304,653 4,236,891 2.1 IV (Future) 13.3 928,609 861,979 5.0 V (Future) 01 928,609 861,979 5.0 VI (Future) 01 577,529 510,899 2.8 Total 55.3 6,739,400 6,471,748 14.9 Notes: Gross Airspace – Volume of airspace from the top of the landfill base liner system through the top of the final cover system. Total Usable Airspace – Volume of airspace for MSW and daily cover and/or alternate daily cover material. Does not include intermediate or final cover material. 1 – Vertical expansion Please contact me at (919) 325-3532 should you have any questions or if there is anything I can do to help facilitate the approval of this request. Sincerely, Aaron M. Weispfenning, P.E. CDM Smith Inc. cc: Jeffery Brown, Cumberland County Martin Sanford, CDM Smith Camp Dresser McKee & Smith CUMBERLAND COUNTY NORTH CAROLINA ANN STREET SUBTITLE D AND C&D LANDFILLS FIGURE 2016 SURVEY AND MODIFIED INTERMEDIATE CLOSURE 1-1 PLAN REPRESENTS PERMITTED CONTOURS RAISED TO EL. 215 AND PROPOSED SLOPE MODIFICATION N Camp Dresser McKee & Smith CUMBERLAND COUNTY NORTH CAROLINA ANN STREET SUBTITLE D LANDFILL FIGURE MODIFIED INTERMEDIATE CLOSURE SECTION 1-2 SECTION 1 HORIZONTAL SCALE 1"=80' VERTICAL SCALE 1"=20' 1 Chao, Ming-tai From:Weispfenning, Aaron <WeispfenningAM@cdmsmith.com> Sent:Wednesday, August 03, 2016 9:23 AM To:Chao, Ming-tai Cc:Sanford, Martin; Jim Blackwell; 'jbrown@co.cumberland.nc.us' Subject:Cumberland County Ann Street Landfill Capacity Modification Attachments:August 2016 Phase III Operating Capacity Modification.pdf Follow Up Flag:Flag for follow up Flag Status:Flagged Ming,    Attached is a letter requesting an adjustment to the capacity of the Ann Street Landfill. The County intends to start  placing additional waste on the eastern slope at the approved slope of 3.5:1 by the end of the week in order to achieve a  uniform slope. Please let me know if there any issues.    Thanks,  Aaron    Aaron M. Weispfenning, P.E. | Engineer | CDM Smith | 5400 Glenwood Avenue, Suite 400 Raleigh, NC 27612 | T: 919‐325‐3532 | F: 919‐781‐5730  |  www.cdmsmith.com