Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MO-30463_49456_CA_UST-61_20240209_24-Hour Release and UST Leak Reporting Form
VT-i 'f 2 "aur� Release and UST Leak Reporting 'Form= For Release This form should be completed and submitted to fhe UST Section's regional office €olI—Ang a known or suspected release from an underground storage tank (UST) system. This form is required to be submitted within 24 hours of discovery of a known or in NC suspected release (DWM USE ONLY) Incident# Risk (H,I,L,U)_- ®_ Suspected Contamination? (Y!N) Confirmed GW Contamination? (YIN) Facility ID Number Al Date Leak Discovered I s 14. Received On Received By Reported by Phone, Fax or Report Confirmed Soil Contamin n ?(YIN) Samples Taken?(YIN) Comm/Non-Commercial? � RegtNon-regulated? lei • (circle one). Region Free Product? (Y/N) If Yes, State Greatest Thickness INCIDENT DESCRIPTION Incident Name: q Address: Q County: a RGG Regional Office (circle one): Asheville mile Fayetteville, Cityfrown: Rn ZipCadeagaa7 I Raleigh, Washington, Wilmington, Winston aem 1�� N.C. Latitude (dedffmr degrees): �.�. 1 ?9/ Longitude (de;rra degrew) : 0, Obtained by: XGPS Briefly describe suspected or confirmed release, (including but not limited to. nature of release, date of release, amount of release, amount of free product present and racoveLv efforts, initial Ts onses conducted, lDm acts to rece tors) ❑Topographic map ❑GIs Address matching ❑Other ❑Unknown Describe location: Jsd 1. 0l S Ren) lw T P Q� CO1f e !S . S0 4 RoMedMAPV W& bJ HOW RELEASE WAS DISCOVERED (Release Code) (Check one) ❑Release Detection Equipment or Methods ❑v'rsuavodor ❑Groundwater Contamination XDuring UST Closure/Removal ❑Water in Tank ❑Surface Water Contamination FlProperty Transfer Water Supply Well Contamination OoMer (specify) SOURCE OF CONTAMINATION Source of Release Cause of Release Tne of Release Product T e Released (Check primary source) (Check primary cause) (Check one) (Check primary product type released) Tank D Spill x Petroleum ❑ Gasounet Dieselt ❑ Dieselveg. Oil Piping ❑ Overfill ❑ Non -Petroleum Kerosene Blend M Dispenser X Corrosion Both CK Heating oil Vegetable Oil 100% ❑Submersible Turbine Pump ❑ PhysigOther Petroleum ❑ E10 - E20i/Mechanical Damage Location Products F1 E21 - E84 Delivery Problem (Check one) Metals iI��tt spill Bucket 1.� install Problem� E85 - E99 ❑ Other inorganics Other [-]Facility Fj Ethanol 100% Other ❑ ❑ Other Organics Unknown �Resictence � E01 - E09 Unknown Other Defin4fons Definitions led on reverse presented on reverse Ownersheu 1. Municipal 2. Military 3. Unknown 4. Private 5. Federal 6. County 7. State Operation Type e- 1. Public Service 2. Agricultural 3, Residential 4. Education/Relig. 5. Industrial 6. Commercial 7. Mining UST Form 151 (02/19) Page 1 of 2 IMPACT ON DRINKING WATER SUPPLIES Water Supply Wells Affected? 1. Yes 2. No 3. Unknown Number of Water Supply Wells Affected Water Supply Wells Contaminated; (include Users Names, Addresses and Phone Numbers. Attach additna/ sheet if necessary) 1. 2. 3. UST SYSTEM OWNER UST Owner/Company Point of Contact TohN A/V IL Fe1t9%jsoNf Email Address '7,21-a JnsL W Q ,ek t O f d city �;�+ State N Zip as TelephoneT- /9 34/3 1 1 / UST Operator/Company UST SYSTEM OPERATOR uoh 2#11- LIs()rJ Email Address r7;. I& MQ W hkkk �o84 City MIP ; State i Zip Code Telephone Number ?a - (9- 13 •C► Landowner C & , O NER�AT LOCATION OF UST INCIDENT Mv Email Address a r o'Zh'rR+2 Aa City M;r,/ Ni'I� State N, C, Zip Code a3;99 7 Telephone Number 1740-619 - RV3 Draw Sketch of Area (showing two major road intersections) or Attach Map �kg a OOK j ] }} E L1 a �I ! 0 tJ9 Person Reporting lncid!2y4fjW/30VrJe Company Cfi Telephone Number7o •6674;> Z Title Address co aes ; I , C. I t / • Dale 49 9 UST Form 51 (02/19) Page 2 of 2 Definitions of Sources Tank: means the tank that stores the product and is part of the underground storage.tank system Piping: means the piping and connectors running from the tank or submersible turbine pump to the dispenser or other end -use equipment (Vent, vapor recovery, or fill lines are excluded.) Dispenser: includes the dispenser and the equipment used to connect the dispenser to the piping (e.g., a release from a suction pump or from components located above the shear valve) Submersible Turbine Pump (STP) Area includes the submersible turbine pump head (typically located in the tank sump), the line leak detector, and the piping that connects the submersible turbine primp to the tank Delivery Problem: identifies releases that occurred during product delivery -to the tank. (Typical causes associated with" source are : pft and overfills.) Other: serves as the option to use when the release source is known but does not fit into one of the preceding categories (e.g., for releases from vent lines, vapor recovery lines, and fill lines) Unknown: identifies releases for which the source has not been determined Definitions of Causes Spill: use this cause when a spin occurs (e.g., when the delivery hose is disconnected from the tank fill pipe or when the nozzle is removed from the dispenser) Overfill: use when an overfill occurs (e.g., overfills may occur from the fill pipe at the tank or when the nozzle fails to shut off at the dispenser) Physical or Mechanical Damage: use for all types of physical or mechanical damage, except corrosion (e.g., puncture of tank or piping, loose fittings, broken components, and components that have changed dimension) Corrosion: use when a metal tank, piping, or other component has a release due to corrosion (e.g., for steel, corrosion takes the form of rust) histallation Problem: use when the problem is determined to have occurred specifically because the UST system was not installed properly Other use thins option when the cause is known but does not fit into one of the preceding categories (e.g., putting regulated substances into monitoring wells) Unknown: use when the cause has not been determined ceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 February 12, 2024 Mr. James Willard II Inenco, Inc. 132 W. Statesville Ave Mooresville, NC 28115 RE: Project: 8501 FARIVIEW RD Pace Project No.: 92711249 Dear Mr. II: Enclosed are the analytical results for sample(s) received by the laboratory on February 01, 2024. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Ariel S Fitzgerald ariel.fitzgerald@pacelabs.com 704-977-0945 Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 12 Project: 8501 FARIVIEW RD Pace Project No.: 92711249 Pace Analytical Services, LLC 9800 KinceyAve. Suite 100 Huntersville, NC 28078 (704)875-9092 Pace Analytical Services Charlotte South Carolina Laboratory ID: 99006 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Laboratory ID: 99006 CERTIFICATIONS South Carolina Certification #: 99006001 South Carolina Drinking Water Cert. #: 99006003 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana DoH Drinking Water #: LA029 Virginia/VELAP Certification #: 460221 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 12 ceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE ANALYTE COUNT Project: Pace Project No.: 8501 FARIVIEW RD 92711249 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92711249001 TANK EPA8015C HH 2 PASI-C EPA 8015C TEG 2 PASI-C SW-846 CHC 1 PASI-C PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 12 ceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: 8501 FARIVIEW RD Pace Project No.: 92711249 Sample: TANK Lab ID: 92711249001 Collected: 02/01/24 10:05 Received: 02/01/24 14:00 Matrix: Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 8015 GCS THC-Diesel Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte Diesel Range Organics(C10-C28) 6820 mg/kg 234 40 02/07/24 13:08 02/08/24 14:20 Surrogates n-Pentacosane (S) 0 % 10-133 40 02/07/24 13:08 02/08/24 14:20 629-99-2 S4 Gasoline Range Organics Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gas Range Organics (C6-C10) 197 mg/kg 14.2 1 02/02/24 12:25 02/02/24 20:31 Surrogates 4-Bromofluorobenzene (S) 151 % 66-130 1 02/02/24 12:25 02/02/24 20:31 460-00-4 S5 Percent Moisture Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture 14.4 % 0.10 1 02/02/24 14:56 N2 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 02/12/2024 06:21 PM without the written consent of Pace Analytical Services, LLC. Page 4 of 12 ceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: 8501 FARIVIEW RD Pace Project No.: 92711249 QC Batch: 829739 Analysis Method: EPA 8015C QC Batch Method: EPA 5030E Analysis Description: Gasoline Range Organics Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92711249001 METHOD BLANK: 4288319 Matrix: Solid Associated Lab Samples: 92711249001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Gas Range Organics (C6-C10) mg/kg ND 6.0 02/02/24 14:30 4-Bromofluorobenzene (S) % 90 66-130 02/02/24 14:30 LABORATORY CONTROL SAMPLE: 4288320 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Gas Range Organics (C6-C10) mg/kg 50 46.6 93 70-130 4-Bromofluorobenzene (S) % 91 66-130 MATRIX SPIKE SAMPLE: 4288322 92710520003 Spike MS MS % Rec Parameter Units Result Conc. Result % Rec Limits Qualifiers Gas Range Organics (C6-C10) mg/kg ND 49.7 22.9 43 57-154 M1 4-Bromofluorobenzene (S) % 90 66-130 SAMPLE DUPLICATE: 4288321 92710520002 Dup Parameter Units Result Result RPD Qualifiers Gas Range Organics (C6-C10) mg/kg ND 2AJ 4-Bromofluorobenzene (S) % 89 90 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 02/12/2024 06:21 PM without the written consent of Pace Analytical Services, LLC. Page 5 of 12 ceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: 8501 FARIVIEW RD Pace Project No.: 92711249 QC Batch: 830601 Analysis Method: EPA 8015C QC Batch Method: EPA 3546 Analysis Description: 8015 Solid GCSV Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92711249001 METHOD BLANK: 4292957 Matrix: Solid Associated Lab Samples: 92711249001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Diesel Range Organics(C10-C28) mg/kg ND 5.1 02/08/24 10:57 n-Pentacosane (S) % 71 10-133 02/08/24 10:57 LABORATORY CONTROL SAMPLE: 4292958 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Diesel Range Organics(C10-C28) mg/kg 67.3 57.5 85 43-130 n-Pentacosane(S) % 81 10-133 MATRIX SPIKE SAMPLE: 4293053 92712002001 Spike MS MS % Rec Parameter Units Result Conc. Result % Rec Limits Qualifiers Diesel Range Organics(C10-C28) mg/kg 409 78.1 609 255 15-130 M1 n-Pentacosane(S) % 90 10-133 SAMPLE DUPLICATE: 4293054 92712002002 Dup Parameter Units Result Result RPD Qualifiers Diesel Range Organics(C10-C28) mg/kg ND ND n-Pentacosane (S) % 77 69 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 02/12/2024 06:21 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 12 ceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: 8501 FARIVIEW RD Pace Project No.: 92711249 QC Batch: 829800 Analysis Method: SW-846 QC Batch Method: SW-846 Analysis Description: Dry Weight/Percent Moisture Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92711249001 SAMPLE DUPLICATE: 4288546 92710862002 Dup Parameter Units Result Result RPD Qualifiers Percent Moisture % 25.3 26.7 5 N2 SAMPLE DUPLICATE: 4288547 92711211001 Dup Parameter Units Result Result RPD Qualifiers Percent Moisture % 79.0 79.1 0 N2 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 02/12/2024 06:21 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 12 ceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALIFIERS Project: 8501 FARIVIEW RD Pace Project No.: 92711249 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TN -The NELAC Institute. ANALYTE QUALIFIERS M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. N2 The lab does not hold NELAC/TNI accreditation for this parameter but other accreditations/certifications may apply. A complete list of accreditations/certifications is available upon request. S4 Surrogate recovery not evaluated against control limits due to sample dilution. S5 Surrogate recovery outside control limits due to matrix interferences (not confirmed by re -analysis). REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 02/12/2024 06:21 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 12 ceo Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Pace Project No.: 8501 FARIVIEW RD 92711249 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92711249001 TANK EPA 3546 830601 EPA 8015C 830937 92711249001 TANK EPA 5030B 829739 EPA 8015C 829789 92711249001 TANK SW-846 829800 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 02/12/2024 06:21 PM without the written consent of Pace Analytical Services, LLC. Page 9 of 12 .lace DC# Title: ENV-FRM-HUN1-0083 v03_Sample Condition Upon Receipt Effective Date: 11/29/2023 4:16.30 PM Laboratory receiving samples: Asheville ❑ Eden[:] Greenwood ❑ Huntersville [I Raleigh❑ Mechanicsville❑ Atlanta❑ Kernersville❑ Sample Condition Client NUpon Receipt ::&etC6TAC_ a� eT Project 1 +_O# ' 92 r 1 1 24J - Courier. Fed Ex LJ ups LJusps Client 111111111111111111111111 ❑ Commercial El Pace El Other: Zr 92711249 Custody Seal Present? El Yes 9 Na Seals Intact? ❑ Yes ❑ No Z N/A .{{� Date/Initials Person Examining Contents: Packing Material: Thermoi,tR er: Gun ID Cooler Temp: ❑ 8ubble Wrap (7To b & Bubble Bags ❑ None ❑ Other Correction FactFactor: Add/Subtract (°C) 1�! Type of Ice: 6�( nWet ❑Blue ❑None Cooler Temp Corrected ('C): USDA Regulated Soil (❑ N/A, water sample) Did samples originate in arantine zone within the United States: CA, NY, or SC (check maosl? ❑ a Yes N❑ Biological Tissue Frozen? []Yes ❑ No ❑ N/A Temp should be above freezing to 6°C ❑ Samples out of temp criteria. Samples on ice, cooling process has begun Did samples originate from a foreign source (intern ivnally, indudine Hawaii and Puerto Ricol? 13Ye ZINo Comments/Discrepancy: Chain of Custody Present? Yes ElNo :1 N/A 1. Samples Arrived within Hold Time? Yes ❑No [I N/A 2. Short Hold Time Analysis (a72 hr.)? ❑ Yes WfNo ❑ N/A 3. Rush Turn Around Time Requested? ❑ Yes NJ No ❑ N/A 4. Sufficient Volume? ❑No ❑N/A 5. Correct Containers Used? ,,dyes CJYes ❑No El N/A 6. -Pace Containers Used? Dyes ❑ No ❑ N/A Containers Intact? Yes ❑ No ❑ N/A 7. Dissolved analysis: Samples Field Filtered? ❑Y s t2'No ❑N/A 8. Sample Labels Match COC? Yes ❑ No ❑ N/A 9. -Includes Oat e/rime/ID/Analysis Matrix:______ Headspace in VOA Vials (>5-6mm)? © Yes ❑ No ii N/A 10. Trip BlankPresent7 ❑Yes El No VN/A 11. Trip Blank Custody Seals Present? ❑ Yes ❑ No NS N/A COMMENTS/SAMPLE DISCREPANCY CLIENT NOTIFICATION/RESOLLfTiON Person contacted: Project Manager SCURF Review: Project Manager SRF Review: Lot ID of split containers: Date/Time: Date: Date: Field Data Required? ❑Yes ❑ No Qualtrax ID: 69614 Paae 1 of 2 Page 10 of 12 Effective Date: 11/14/2022 *Check mark top half of box if pH and/or dechlorination is verified and within the acceptance range for preservation samples. Exceptions: VOA, Coliform, TOC, Oil and Grease, DR018015 lvlat?ri DOC. LLHg "Bottom half of box is to list number of bottles 'Cheek ail unpreserved Nitrates for chlorine Project # WO#:92711249 PM: RSF Due Date: 02/15/24 CLIENT: 92—INENCO Z. u I` u a 'J N Ci - v q ry y dj M a G `- 7 v L1 m r-, r a z 2 =' v U ^ ! > > u_Al ri > a E u� c a v7 c Y ,� a [NJ n a E M Z x C E Q N m A r O = a 1 Q ii _ v c u � a c E c ¢ a `a a c y C E D rV v ? �, x T -- M Z t=r c e E O ¢ ¢ > N 1 4 ✓t C3 c ? c m o Q 7 `v I >> a > i Q J = c c 9 Z o 9 7 �_ J n c E ¢ C y = Q tl_ m 7 m R m c O - a V1 N a a- a in m 2 A m t E ry 0. I to E rJ I a to �_ 1 - l7 C7 3 a a � V' a �+ E = n 0 l:1 t7 C7 C9 ¢ ¢ o cr E E " E .a O 0 p � M ' r t ~' U` I t7 t7 l7 A a > > a >c } ,n c E c E 0 no O ry rn t7 r1 tL t7 yr �, —I m a > c to l7 o Z \ I —'N1 1i I NIN — 11] 1 1 IINNN 5 G N 1. 1 I4\f\d \ I\ I 'N \ - \NN I �� a NI I \N\N, 'oN I I IN i IN 1 1. -- � 12 Nr'\J 'l \ 5ample ID pH Adjustment Log for Preserved Samples Type of Preserv, Gve li pH upon receipt Date preservation adjusted Time preservation adjusted -Amount of Preservative T lot d added Note Wherwver there is a discrepancyaffectrng North Carolina Compliance samples. a copy of this farm %vlll be sent to the rdartli Carolina DENR Cert,f icatlon Office Is Out of hold, incorrect preservative, out el tenip, IncorreC! containers. Quaitrax ID. 69614 Page 2 of 2 Page 11 of 12 ITEM # ; 3 n n p( c 0 c oq D = o s 0 o _ 4SEr �`' - m� r m 7 ` a =. r \ m .� o v rn D 3 m C m e L m oC. C. ° z :a (n v v m n �rnX`LOrv`{1{` m Y ro o o a ?. Z z r 3 3 v W MATRIX CODE Isee valid codes to left) i 0 z P o SAMPLE TYPE (G=GRAB C=COMP) mm v n o to m H n � K > O _ Cn v r 0 ~ r I re - ti m m 71 0 r m ti i A z D z n M -4 z m m o° O 4 m m 3 n D z o y y ➢ v D v z I m r r m � A m SAMPLE TEMP AT COLLECTION I m In # OF CONTAINERS n ? a G y "- a 3 - Unpreserved m wso., Z G o� HNO3 3 3 0. HCI w NaOH Na2SZ03 Methanoi 1'1 oOther m JAnalysis Test j YlN; n r i m 3 -➢i m I r CD N < Z CD T a CL D � 4 1 L In o r- Rs m T m D In -13 CD 1 a 0 > m n O z Z D n j n Temp in °C r Residual Chlorine (YIN) ➢ m Received oncn Sl Ice (YIN) n > 3 u m n m N O O Cusl°dy Sealed Cooler p (YIN( c n n m z -( 0 p ]� A z o z z Cn D Samples Inlact 0.� m (YIN) V. M O Ppqe1 of 12 `, 0 z O n 0 C .4 v D1 < 0 a1 :l] tD C (D N_ v O n t3D From: Beverly, Trudy To: Larry Boone; rro(a)inencoinc.com Subject: RE: [External] UST removal at 8501 Fairview Road -Mint Hill, N. C. Date: Wednesday, February 14, 2024 1:22:00 PM Attachments: imaae001.a_na Good Afternoon Larry, Thank you for submitting the release reporting form and sample results. The signed/sealed pdf report can be emailed to me when completed. Let me know if you have questions. Have a great day, Trudy Trudy Beverly, L.G. Hydrogeologist, Division of Waste Management North Carolina Department of Environmental Quality UST Section, Mooresville Regional Office 704.235.2182 (Office) Trudy.Beverly�a deq.nc.gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Office Mailing Address: 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Branch's Underground Storage Tanks Website Address: httns://deq.nc.gov/about/divisions/waste-management/ust Branch's Above Ground Storage Tanks Website Address: hums://deq.ne.gov/about/divisions/waste-management/ust/ast-program INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES: httns://deo.nc. gov/about/divisions/waste-management/waste-management-rules-data/waste-management-ais-mans File Review Procedures: h=s://deq.nc. gov/about/divisions/waste-management/ust/file-review-procedures#mooresville-regional-office ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche): hUs://deq.nc.gov/about/divisions/waste-management/laserfiche Document Submittal & UST File Names for Laserfiche Policies: httlis:Hfiles.nc.gov/ncdeq/W aste°/`2OManagement/DWM/USTfWhatsNew/Final-Electronic-Document-Submittal-Policy_Rdf httns://files.nc. gov/ncdeq/Waste%20Mana2ement/DWM/UST/Corrective%2OAction/UST%20file%20names%20for%2OLaserfiche. docx From: Larry Boone <tankdigger@carolina.rr.com> Sent: Wednesday, February 14, 2024 1:04 PM To: Beverly, Trudy <trudy.beverly@deq.nc.gov> Subject: [External] UST removal at 8501 Fairview Road -Mint Hill, N. C. CAUTION: External email. Do not click links or open attachments unless verified. Report suspicious emails with the Report Message button located on your Outlook menu bar on the Home tab. Hello, Trudy, we removed two 550 gallon home heating oil tanks at the Fairview Road Location in Mint Hill. The lab results show one of the areas is contaminated. We removed a total of 14.35 tons of soil that was taken to the disposal facility. Attached are the UST- 61 and lab results for the site. I am working with Ryan Osborne on this site. Please let me know if you need any further information. Thanks, Larry Boone