HomeMy WebLinkAboutSDTF9802_INSP_20201105NORTH CARnLINAD_E Q�/�� oenammem m c.wm.mnnai Wei FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer Compost SLAS COUNTY: Wilson MSWLF PER MIT NO.: SDTF-98-02 Closed HHW White Incin UP FIRM MSWLF goods FILE TYPE: COMPLIANCE CDLF TireT&P/ Tire Industrial DEMO SDTF X Collection Monolill Landfill Date of Site Inspection: 11 /05/2020 Date of Last Inspection: 07/10/2020 FACILITY NAME AND ADDRESS: Rosalee Mitchell and Maurice Mitchell Jr. Mitchell's Septic Tank Cleaning Service Inc. 6522 Speight School Road Wilson, NC 27893 GPS COORDINATES: N: 35.65804 FACILITY CONTACT INFORMATION: Name: Maurice Mitchell Address: 6532 Speight School Rd. — Wilson, NC 27893 Telephone: 252-363-1807 Email address: mitchellsseptic2226@yahoo.com PARTICIPANTS: Chester Cobb (DWM) STATUS OF PERMIT: Active PURPOSE OF SITE VISIT: E:-77.80410 EXPIRES: 0610112020 (expired) Routine STATUS OF PAST NOTED VIOLATIONS: No violation noted on the previous inspection. OBSERVED VIOLATIONS: 1) Grease septage overflowed the second tank and flowed onto the ground. The overflow of septage from the second tank onto the ground is a violation of Rule 15A NCAC 13B .0838(e)(1) that states "Each detention and treatment facility shall be designed, constructed, and maintained to: (1) prevent leaks or the flow of septage out of the facility into the seasonally high water table, onto the ground surface, or into any surface waters." Septage needs to be cleaned up off the tank and ground. The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. Page 1 of 2 FACILITY COMPLIANCE INSPECTION REPORT ��n1��;poii� D_E Q�� Division of Waste Management Oepa.lmen f Envimnmental0ualiry Solid Waste Section ADDITIONAL COMMENTS 1) This facility consists of two 10,000-gallon steel tanks for the storage of domestic and grease septage. 2) The "No Trespassing" sign was posted before you get to the tanks. 3) Access road to the facility is in good shape. 4) Tanks accessible for inspection. An area around the tank greater than 5 feet was clear of any debris or vegetation hiding the walls of the tank. 5) Grease septage overflowed the second tank and flowed onto the ground. The overflow of septage from the second tank onto the ground is a violation of Rule 15A NCAC 13B .0838(e)(1). See picture below. Septage needs to be cleaned up off the tank and ground. Outside of the overflow of septage onto the ground, no leaks noticed. 6) No objectionable odors or vector issues noticed today. 7) No changes noticed that would impact setback distances. 8) No application for permit renewal has been received. Talked to Maurice in Decemberabout needing the application. Please contact me if you have any questions or concerns regarding this inspection report. Digitally signed by Chester R. Cobb c cn=Chester R. Cobb, o=Solid Waste Section, ou=DWM, email=chester.cobb@ncdenr.gov, c=US Date: 2021.06.22 15:02:24-04'00' Phone: (919) 707-8283 . Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: X Email Hand delivery US Mail Certified No. L_J Page 2 of 2