HomeMy WebLinkAbout3902_Granville_Butner_MSWLF_Sept24LFG_FID1901516_20241007DENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #:
NC DENR I IEnvironmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
Prepare one form for each individually monitored unit.
Please type or print legibly.
Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification
must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing
condition, etc.).
Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits.
Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, NC 27699-1646.
Solid Waste Monitoring Data Submittal Information
Name of entity submitting data (laboratory, consultant, facility owner):
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name: Craig Fortner Phone: 919-815-4221
E-mail: cfortner@garrett-moore.com
NC Landfill Rule: Actual sampling dates (e.g.,
Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006)
Butner Landfill 2796 Old NC 75 39-02 .1600 September 30, 2024
Butner, NC 27509
Environmental Status: (Check all that apply)
❑ Initial/Background Monitoring X❑ Detection Monitoring ❑ Assessment Monitoring Corrective Action
of data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells IN
Groundwater monitoring data from private water supply wells ❑
Leachate monitoring data El
water monitoring data
Methane gas monitoring data
Corrective action data (specify)
Other(specify)
Notification attached?
e No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration.
❑ Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
Craig M. Fortner, PF Project Manager 919-815-4221
Facility,Represeq,tati "ame (Print) Title (Area Code) Telephone Number
October 7, 2024
Date
Garrett & Moore, Inc., 1029 W. South St., Raleigh, NC 27603
Facility Representative Address
C-2910
NC PE Firm License Number (if applicable effective May 1, 2009)
Affix NC Lice nVk% tb4W"I Geologist Seal
CARO .
�vo�°°°°°°°°° o<iee
, ��FESS�O ° o°
°
g SEAL 00
o =
029929 S
°
°
%
,9°
°�IN°"�Cp°°°GE
�
°
°°Ij ���
Revised 6/2009
GARRETTE/
& MOORE000
Engineering for the Power and Waste Industries
October 7, 2024
Ms. Jackie Drummond
North Carolina Department of Environment and Natural Resources
Division of Waste Management, Solid Waste Section
1646 Mail Service Center
Raleigh, NC 27699-1614
RE: Landfill Gas Monitoring Report
3rd Quarter Sampling Event of 2024
Granville County — Butner Closed MSW Landfill
Permit # 39-02
Dear Ms. Drummond:
Attached please find the Landfill Gas Monitoring Log and Gas Probe Location Map for the third
quarter monitoring event that occurred on September 30, 2024 at the Granville County Butner
Landfill (Permit number 39-02) for inclusion in your records. Methane was not detected in any
monitored location during this event above any regulatory action level. Additionally, hydrogen
sulfide was not detected in any monitored location during this event.
Landfill gas monitoring will continue on a quarterly basis for the Butner Landfill. If you have any
questions, please do not hesitate to call me at 919-792-1904.
Sincerely,
Garrett & Moore, Inc.
Craig M. Fortner, P.E.
Cc: Jason Falls, Granville County
1029 W. South Street • Raleigh, North Carolina 27603 • O: 919-792-1900 • F: 866-311-7206
\ APPROXIMATE MW 5
\ \ LOCATION
\I PROPERTY LINE _
\� GP-2
i SW-1
AGV
AGV
I\ \ APPROXIMATE\ / GV \ I ��YYYY-MW-4
LIMITS OF WASTE ` - G\ I I I \
I V
/ CREEK
CENTERLINE) /
` I
MW-3R
SW-2 M
. I MT2R \ \ Z
J
0
Ai
Jz
I
LEGENDLL
J I-
--- 0
/ I \ I I I I \ \ \ �., _ 130 EXISTING 25' TOPOGRAPHIC CONTOUR z O
�� \ EXISTING 5' TOPOGRAPHIC CONTOUR Q Z
_ PROPERTY LINE J }
APPROXIMATE LIMITS OF WASTE LLI z
/ zZ)
EXISTING ROAD �— O
MW-1R
CENTERLINE OF STREAM D U
\ / GROUNDWATER MONITORING WELL
MW iR LOCATION AND IDENTIFICATION J
GP-1 GAS PROBE LOCATION AND >
���IDENTIFICATION z
� GV GAS VENT
\ -
O� SW-1 SURFACE WATER MONITORING POINT
Gp-q �
— / (NM) NOT MEASURED
m / V
5 Jt APPROXIMATEGPE LIMITS OF WASTENOTES
1. TOPOGRAPHIC CONTOUR INTERVAL = 5 FEET
2. STATIC WATER LEVELS MEASURED ON 12/12112.
777
3. ELEVATION RELATIVE TO MEAN SEA LEVEL.
GfRAPHIC SCALE 4. TOPOGRAPHIC CONTOURS SHOWN IN THIS MAP ARE BASED ON
50 .100 200 2007 DATA OBTAINED FROM NCDOT WEBSITE.
_5. BOUNDARYSURVEYPROVIDEDBY BATEMAN CIVIL SURVEY
(FEET) COMPANY DATED MARCH 15, 2013.
v
PROJECT NO.
660.1201.12
SCALE
AS NOTED
DRAWING NO.
1
0
w
w
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Butner Landfill
Number: 39-02
Sampling Date: September 30, 2024 NC Landfill Rule (.0500 or.1600): • 1600
Sample Collector Name & Position: Craig Fortner, Project Manager
Gas Meter Type & Serial Number: GEM5000
Field Calibration Date & Time: 9/30/2024; 1139
Gas Meter Calibration Date: 10/03/2023
Field Calibration Gas Type (15115 or 35/50): 35/50 Field Calibration Gas Canister Expiration Date: 4/26/2027
Gas Meter Pump Rate:
50 cc/min
Ambient Air Temperature: 82 Barometric Pressure (in. or mm Hg): 29.45 Weather Conditions: P. Sun
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by
volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) x 20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills
(CDLFs). See individual permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well ID
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
% LEL
Stabilized
% LEL
% CH4
(volume)
volume
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
GP-1
2 min
1150
60 sec
0
0
0
11.6
11.6
0
GP-2
2 min
1155
60 sec
0
0
0
10.4
14.4
0
GP-3
2 min
1206
60 sec
0
0
0
19.5
2.0
0
GP-4
2 min
1232
60 sec
0
1.8
0.9
16.1
6.5
0
GP-5
2 min
1229
60 sec
0
0
0
10.2
13.7
0
GP-6
2 min
1223
60 sec
0
0
0
2.4
12.0
0
Scales
2 min
1241
60 sec
0
0
0
20.0
0.2
0
Shed
2 min
1245
60 sec
0
0
0
20.5
0.3
0
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and
attachments are true and correct. I am aware that there are significant penalties for making any false statement,
represe tation, o certification including the possibility of a fine and imprisonment.
Project Manager
, A/�
SI ATUA TITLE
Revised —August 23, 2021