Loading...
HomeMy WebLinkAboutSDTF4104_INSP_20220824NORTH CARnLINAD_E Q�� o.n.mm.m m c.wmmm�n.i a.i� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer Compost SLAS COUNTY: Guilford MSWLF PER MIT NO.: SDTF-41-04 Closed HHW White Incin UP FIRM MSWLF goods FILE TYPE: COMPLIANCE CDLF TireT&Pi Tire Industrial DEMO SDTF X Collection Monolill Landfill Date of Site Inspection: 08/24/2022 Date of Last Inspection: 09/21/2021 FACILITY NAME AND ADDRESS: Mr. Ronnie Overbey Triad Industrial Services, Inc. 4712 Old Burlington Road Greensboro, NC27405 GPS COORDINATES: N: 36.08879 FACILITY CONTACT INFORMATION: Name: Ronnie Overbey Address: 5301 Burlington Road—McLeansville, NC27301 Telephone: 336-697-8169 or 336-382-4173 Email address: overbeys@bellsouth.net PARTICIPANTS Chester Cobb (DWM) E:-79.69138 STATUS OF PERMIT: Active EXPIRES: 0813112023 PURPOSE OF SITE VISIT: Routine STATUS OF PAST NOTED VIOLATIONS: None listed on the previous inspection. OBSERVED VIOLATIONS: NONE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violationof the Solid Waste Laws, Regulations, Conditions of a Permit; or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. Page 1 of 2 Oepartmenl o� Envimnmental0uali� ADDITIONAL COMMENTS FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section 1) The "No Trespassing" sign was posted at the front of the building facing the state road. 2) Access road to the facility is in good shape. 3) The screening tank is located behind the building and has a cover. From the screening tank, the septage is pumped into two 10,000-gallon stainless steel tanks inside an enclosed building. From the storage tanks, the septage is pumped to the adjacent building where the septage is dewatered. Facility does not appear to be used much. 4) Tanks accessible for inspection. 5) No evidence of any holes that may allow the inadvertent escape of septage from the two above ground steel tanks. No leaks noticed. Tanks were empty. 6) It appears that the septage is transferred to and from the facility in such a manner to preventspills of septage from occurring. No spills noticed today. 7) No objectionable odors or vector problems noticed. 8) No changes noticed that would impact setback distances. Please contact me if you have any questions or concerns regarding this inspection report. Digitally signed by Chester Cobb DN: cn=Chester Cobb, o=NC DEQ, ou=Division of Waste Management, email=chester.cobb@ncdenr.gov, c=Us Date: 2023.02.10 15:57:30-05'00' Phone: (919) 707-8283 . Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: X Email Hand delivery US Mail Certified No. L_J Page 2 of 2