Loading...
HomeMy WebLinkAboutNCS01690_INSP_20230616� 1E FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer Compost SLAS COUNTY: Davidson MSWLF PER MIT NO.: NCS-01690 Closed HHW White Incin UP FIRM X MSWLF goods FILE TYPE: COMPLIANCE CDLF TireT&P/ Tire Industrial DEMO SDTF Collection Monolill Landfill Date of Site Inspection: 06/16/2023 FACILITY NAME AND ADDRESS: Drews Septic Service 8697 NC Hwy 8 Lexington, NC 27292 GPS COORDINATES: N: NA Date of Last Inspection: FACILITY CONTACT INFORMATION: Name: Steve "Drew" Money Address: 23401 NC Hwy 8 — Denton, NC 27239 Telephone: 336-250-9520 Email address: drewmoney30na,gmaiL com PARTICIPANTS Chester Cobb (DWM), Drew Money STATUS OF PERMIT: PURPOSE OF SITE VISIT Pending EXPIRES Pre -operational STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: NONE E: NA The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violationof the Solid Waste Laws, Regulations, Conditions of a Permit or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. Page 1 of 2 FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section ADDITIONAL COMMENTS 1) Pumpervehicle(s) inspected: TRUCK LICENSE PLATE # VIN # TANK CAPACITY (gal) 21 YA166584 1FDZU90L9KVA07041 3,000 2) The required information of Firm name, town name, phone #, and permit # was on both sides of the pumper vehicle. Each letter of the required information was greater than three (3) inches in height. The lettering was distinguishable and not blocked from view. The lettering meets the requirements of 15A NCAC 13B .0835(b). See pictures below. 3) The tank is made of steel and affixed to the frame of the truck with bolts as per 15A NCAC 13B .0835(a)(1). One bolt was missing a nut. Please replace the nut. A couple of other bolts were loose. The bolts were tightened while I was onsite. 4) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present on ports. 5) Access ports were closed and properly sealed as per 15A NCAC 13B .0835(a)(3). 6) No leaks noticed as per 15A NCAC 13B .0835(a). r Driver side of pumper vehicle. I Passenger side of pumper vehicle. I Please contact me if you have any questions or concerns regarding this inspection report. Digitally signed by Chester Cobb DN: Chester Cobb, o=NC DEQ, ou=Division of Waste Management, �;gemail=chester.cobb@ncdenr.gov, c=US an-x? Date: 2023.06.2117:00:57-04'00' Phone: (919) 707.8283 Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: X Email Hand delivery US Mail Certified No. L_1 Page 2 of 2