Loading...
HomeMy WebLinkAboutNCS01749_INSP_20240411NORTH CARnLINAD_E Q�� o.n.mm.m m c.w.mm.m.i a.i� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer Compost SLAS COUNTY: Moore MSWLF PERMIT NO.: NCS-01749 Closed HHW White Incin T&P FIRM X MSWLF goods FILE TYPE: COMPLIANCE CDLF Tire T&P/ Tire Industrial DEMO SDTF Collection Monofill Landfill Date of Site Inspection: 04/11/2024 FACILITY NAME AND ADDRESS: Superior Septics 608 Dogwood Street Aberdeen, NC 28315 GPS COORDINATES: N: NA Date of Last Inspection: FACILITY CONTACT INFORMATION: Name: Patrick Lee Gallimore Address: Same as above Telephone: 910-690-1336 Email address: superiorsgpticswork(a mail.com PARTICIPANTS: Chester Cobb (DWM) and Patrick Gallimore STATUS OF PERMIT: Pending EXPIRES: PURPOSE OF SITE VISIT: Pre -operational STATUS OF PAST NOTED VIOLATIONS: N.A. OBSERVED VIOLATIONS: NONE E: NA The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. Page 1 of 2 NORTH CARnLINAD_E Q�� oen.mmem m c.w.mmnnai a.i� ADDITIONAL COMMENTS 1) Pumper vehicle(s) inspected: FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section TRUCK LICENSE PLATE # VIN # TANK CAPACITY (gal) i TV-5053 1HTSCAAMXWH553999 2,000 2) The required information of Firm name, town name, phone #, and permit # was on both sides of the pumper vehicle. Each letter of the required information was three (3) inches or greater in height on the pumper vehicle. The lettering was distinguishable and not blocked from view. The lettering meets the requirements of 15A NCAC 13B .0835(b). See pictures below. 3) The tank on the pumper vehicle was made of steel and affixed to the truck bed with bolts as per 15A NCAC 13B .0835(a)(1). 4) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present on ports. 5) Access ports were closed and properly sealed as per 15A NCAC 13B .0835(a)(3). 6) No leaks noticed as per 15A NCAC 13B .0835(a). 7) Pumper vehicle in compliance with the Septage Rules. $UPE/i/OR SEPTjC (910) 690-1336 `S Aberdeen, NC iee srvgca , Permit #NCS01749 SUPERIOR SFpT100 R0 Aberdeen,% Permit t2NCS01749 Left side of the pumper vehicle. I Right side of the pumper vehicle. Please contact me if you have any questions or concerns regarding this inspection report. - a-91' �g Phone: (919) 707-8283 Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: 0 /16/2024 X Email Hand delivery US Mail Certified No. L-j Page 2 of 2