Date of Site Inspection: 04/17/2024
FACILITY NAME AND ADDRESS:
Mr. 011ie Merritt
New Day Septic
1836 Ferrells Bridge Rd.
Louisburg, NC 27549
GPS COORDINATES: N: NA
Date of Last Inspection: 10/27/2021
FACILITY CONTACT INFORMATION:
Name: 011ie Merritt
Address: PO Box 701— Youngsville, NC 27596
Telephone: 919-632-3834
Email address: newdayseptic@gmail.com
PARTICIPANTS: Chester Cobb (DWM) and 011ie Merritt
STATUS OF PERMIT: Active EXPIRES: 1213112024
PURPOSE OF SITE VISIT: New Vehicle
STATUS OF PAST NOTED VIOLATIONS:
None.
OBSERVED VIOLATIONS:
NONE.
E: NA
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance
with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an
administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit,
or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to
enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and
any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.
Page 1 of 2
Oepartmenl o� Envimnmental0uali�
1) Pumper vehicle(s) inspected:
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
TRUCK
LICENSE PLATE #
VIN #
TANK CAPACITY (gal)
0
YA181931
2NK5UOX7RM372999
4,000
2) The required information was on both sides of the pump truck. Each letter of the required information
was greater than three (3) inches in height. The lettering was distinguishable and not blocked from view.
The lettering meets the requirements of 15A NCAC 13B .0835(b). See pictures below. A phone number
of 984-295-8353 was listed on the pump truck but not listed on the application. In the future, please be
sure that the phone number listed on the pump truck is also listed on the application.
3) The tank is made of steel and affixed to the frame of the truck as per 15A NCAC 13B .0835(a)(1).
4) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present
on ports.
5) Access ports were properly sealed with lids that were closed as per 15A NCAC 13B .0835(a)(3).
6) No leaks noticed as per 15A NCAC 13B .0835(a).
7) Truck in compliance with the Septage Rules.
LOUISBURG NO NOS 01434
�LOUISBURG NC NCS01434 r
Driver side of vehicle. Passenger side of vehicle.
Please contact me if you have any questions or concerns regarding this inspection report.
Phone: (919) 707-8283 .
Chester R. Cobb, Environmental Program Consultant
Division of Waste Management, NCDEQ
Regional Representative
Environmental Senior Specialist
Regional Representative
Sent on: 08/16/2024
X
Email
Hand delivery
US Mail