Loading...
HomeMy WebLinkAboutNCS01682_INSP_20240531NORTH CARnLINAD_E Q�� o.n.mm.m m c.w.mm.m.i a.i� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer Compost SLAS COUNTY: Union MSWLF PERMIT NO.: NCS-01682 Closed HHW White Incin T&P FIRM X MSWLF goods FILE TYPE: COMPLIANCE CDLF TireT&P/ Tire Industrial DEMO SDTF Collection Monofill Landfill Date of Site Inspection: 05/31/2024 FACILITY NAME AND ADDRESS: Union Septic Solutions, LLC 3329 Ansonville Road Marshville, NC 28103 GPS COORDINATES: N: NA Date of Last Inspection: 05/16/2023 FACILITY CONTACT INFORMATION: Name: Steve Venegas Address: Same as above Telephone: 980-346-1405 Email address: unionsepticsolutionsllc@gmail.com E: NA PARTICIPANTS: Chester Cobb (DWM) and Steve Venegas STATUS OF PERMIT: Active EXPIRES: 1213112024 PURPOSE OF SITE VISIT: New Vehicle STATUS OF PAST NOTED VIOLATIONS: NA OBSERVED VIOLATIONS: NONE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. Pagel of 3 Oepartmenl o� Envimnmental0uali� ADDITIONAL COMMENTS 1) Pumper vehicle(s) inspected: FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section TRUCK LICENSE PLATE # VIN # TANK CAPACITY (gal) 0 VA-4859 1FVACXAK83HL99545 2,500 2) The required information of Firm name, town name, phone #, and permit # was on both sides of the pumper vehicle. Each letter of the required information was greater than three (3) inches in height. The lettering was distinguishable and not blocked from view. The lettering meets the requirements of 15A NCAC 13B .0835(b). See picture below. 3) The tank is made of steel and affixed to the frame of the truck as per 15A NCAC 13B .0835(a)(1). 4) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present on ports. 5) Access ports were closed and properly sealed as per 15A NCAC 13B .0835(a)(3). 6) No leaks noticed as per 15A NCAC 13B .0835(a). 7) Requested pipe below tank to be capped or plugged. Pipe appeared the be connected to an old pump attached to the tank. Pump no longer in use. Picture received on 06/02/2024 showing that the pipe had been capped or plugged. See pictures below. 8) Truck in compliance with the Septage Rules. ^ SEPTIC SOLUTIONS, LLC - •_• - C• NEW I NSTALLATIONS • SEPTIC PUMPING •REPAIRS —77-yl� r T RSHVILLE, NC . o — _ NMI 1 �A.' • ' 1 1 Page 2 of 3 FACILITY COMPLIANCE INSPECTION REPORT �INA- Division of Waste Management Oepartmen �Envimnmental0ualiry C � • � t� � � ry � Please contact me if you have any questions or concerns regarding this inspection report. Phone: (919) 707-8283 . Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: 0 03/2024 X Email Hand delivery US Mail Certified No. f—] Page 3 of 3