Loading...
HomeMy WebLinkAboutSDTF-04-09_INSP_20240626NORTH CARnLINAD_E Q�� o.n.mm.m m c.w.mm.m.i a.i� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer Compost SLAS COUNTY: Anson MSWLF PERMIT NO.: SDTF-04-09 Closed HHW White Incin T&P FIRM MSWLF goods FILE TYPE: COMPLIANCE CDLF TireT&P/ Tire Industrial DEMO SDTF X Collection Monofill Landfill Date of Site Inspection: 06/26/2024 FACILITY NAME AND ADDRESS: Liquid Waste Inc. 2323 Diggs Road Wadesboro, NC 28170 GPS COORDINATES: N: 34.9055' Date of Last Inspection: 11/10/2021 FACILITY CONTACT INFORMATION: Name: Ronnie Oaks Address: P.O.Box 19491, Charlotte, NC 28219 Telephone: (704) 848-8801 Email address: oaks@liquidwastes.com E:-79.9822' PARTICIPANTS: Lee Sorrell, DWMSolid Waste Section STATUS OF PERMIT: Expired EXPIRES: December 19, 2022 PURPOSE OF SITE VISIT: Routine STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: N/A The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. Page 1 of 4 FACILITY COMPLIANCE INSPECTION REPORT D_E Q�� Division of Waste Management NORTH CAROLINA OepaNnent of Environmental 0ualiry Solid Waste Section ADDITIONAL COMMENTS 1) 15A NCAC 13B .0838(b): An all-weather access road is maintained. 2) 15A NCAC 13B .0838(c): No holes or cracks which may allow the escape of septage were noted. 3) 15A NCAC 13B .0838(e)(2) and .0838(g): No vector or odor issues were noted. 4) 15A NCAC 13B .0838(i): No debris or vegetation was noted within 5 feet of the tank(s) that hinders the inspection of the tanks(s). 5) 15A NCAC 13B .0838(j): Septage appears to be transferred to and from the detention facility in a manner that prevents leaks or spills of septage onto the ground surface or exterior surface of the detention system. 6) 15A NCAC 13B .0838(k): Proper "No Trespassing" signage was posted on site. 7) 15A NCAC 13B .0838(m): Setback requirements appear to have been met. 8) Additional comments: N/A Page 2 of 4 Oepartmenl o� Envimnmental0uali� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Page 3 of 4 Oepartmenl o� Envimnmental0uali� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section Please contact me if you have any questions or concerns regarding this inspection report. Lee Sorrel I Sorrell Date:202 06.2809:19:10 -04'00' Lee Sorrell, Environmental Specialist II Division of Waste Management, NCDEQ Regional Representative Office: (919) 707-8292 Mobile: (919) 703-7934 Email: lee. sorrell@deq.nc.gov Sent on: 06/26/2024 X Email Hand delivery US Mail Certified No. Lj Page 4 of 4