Loading...
HomeMy WebLinkAboutNCS01644_INSP_20221208NORTH CARnLINAD_E Q�� o.n.mm.m m c.w.mm.m.i a.i� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer Compost SLAS COUNTY: Rockingham MSWLF b PERMIT NO.: NCS-01644 Closed HHW White Incin T&P FIRM X MSWLF goods FILE TYPE: COMPLIANCE CDLF Tire T&P/ Tire Industrial DEMO SDTF Collection Monofill Landfill Date of Site Inspection: 12/08/2022 FACILITY NAME AND ADDRESS: Billingsley & Brooks 149 Penn Road Reidsville, NC 27320 GPS COORDINATES: N: NA Date of Last Inspection: FACILITY CONTACT INFORMATION: Name: Roger Billingsley II Address: Same as above Telephone: 336-342-0608 Email address: billingsleynbrooksst@,gmail.com E: NA PARTICIPANTS: Chester Cobb (DWM), Roger Billingsley, and Seth Brooks STATUS OF PERMIT: Pending EXPIRES: PURPOSE OF SITE VISIT: Pre -operational STATUS OF PAST NOTED VIOLATIONS: NA OBSERVED VIOLATIONS: NONE The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. Pagel of 3 Oepartmenl o� Envimnmental0uali� ADDITIONAL COMMENTS 1) Pumper vehicle(s) inspected: FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section TRUCK LICENSE PLATE # VIN # TANK CAPACITY (gal) Pi #1 YA154982 2FZXKWYB3XAA81212 3,500 0 #2 YA154981 1FDXF7DE3JDF03457 2,500 2) The required information of Firm name, town name, phone #, and permit # was on both sides of each pumper vehicle. Each letter of the required information was three (3) inches in height. The lettering was distinguishable and not blocked from view. The lettering meets the requirements of 15A NCAC 13B .0835(b). See pictures below. 3) The tanks on both pumper vehicles were made of metal and affixed to the frame of the trucks as per 15A NCAC 13B .0835(a)(1). 4) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present on ports. 5) Access ports were closed and properly sealed as per 15A NCAC 13B .0835(a)(3). 6) No leaks noticed as per 15A NCAC 13B .0835(a). 7) Trucks in compliance with the Septage Rules. 8) Permit issued on 01/09/2023. Page 2 of 3 Oepartmenl o� Envimnmental0uali� Elm BILLINGSLEY & BROOKS Eft qTC 342,0608 NCgp1Ui44 FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section h 81LLINGSLEY - eRGGKS _ 342-06...�..� REIOSVILLE, NC NCSG1fi4444 i Driver side of pumper vehicle #2 as identified above. Passenger side of pumper vehicle #2 as identified above. Please contact me if you have any questions or concerns regarding this inspection report. Digitally signed by Chester Cobb DN. cn=Chester Cobb, ane ou=Division of Waste Management, email=chester.cobb@ncdenr.gov, c=US Date: 2023.02.09 17:04:55-05'00' Phone: (919) 707-8283 Chester R. Cobb, Environmental Program Consultant Division of Waste Management, NCDEQ Regional Representative Sent on: X Email Hand delivery US Mail Certified No. L-j Page 3 of 3