HomeMy WebLinkAboutRA-30157_49212_CA_SCH_20230911 AECOM AECOM 704.522.0330 tel. 6000 Fairview Road, Suite 200 Charlotte, NC 28210 September 11, 2023 Mr. Mark Powers AECOM Project # 60702558 North Carolina Department of Environmental Quality Division of Waste Management – UST Section 1628 Mail Service Center Raleigh, North Carolina 27699 Subject: Site Check Report Speedway #6975 1741 Trawick Road, Raleigh, NC 27604-3836 Facility ID# 0-036640 Dear Mr. Powers: AECOM Technical Services, Inc. of North Carolina (AECOM) on behalf of Speedway, LLC (Speedway) is presenting this Site Check Report for the above referenced store. On June 23, 2023, the North Carolina Department of Environmental Quality (NCDEQ) inspector noted that there were non-passing results for the premium unleaded (PUL) spill bucket during the December 15, 2020, triennial operability test. During the December 15, 2020, triennial testing, the secondary containment of the spill bucket failed integrity testing and the primary was not tested prior to the installation of the new PUL spill bucket installed on January 11, 2021. A UST-17A form was filed with the North Carolina Department of Environmental Quality (NCDEQ) on June 26, 2023, included as Attachment A. To determine if a release may have occurred to the environment, assessment activities were conducted as documented in this report. A soil boring log has been included as Attachment B, and the laboratory report for the samples collected during the site check has been included as Attachment C. There are no active or historical release incidents associated with the Site. SITE ACTIVITIES Soil and Groundwater Sampling On August 9, 2023, AECOM met with Sweetwater Utility Exploration (Sweetwater) at the site to collect soil sample (SS-1) near the 6,000-gallon premium spill bucket (Figure 1). Sweetwater air knifed the soil boring to a depth of approximately 2.5 feet below ground surface (bgs), then AECOM used a hand auger to collect the soil sample. The sample was collected at approximately 2.5 feet bgs and screened with a photoionization detector (PID). AECOM bottled the sample for laboratory analysis for total petroleum hydrocarbons for gasoline range organics (TPH-GRO) and diesel range organics (TPH-DRO). AECOM Site Check Report September 2023 Speedway 6975 Page 2 Raleigh, North Carolina The samples were submitted to Pace Analytical Services in Huntersville, North Carolina for analysis at the Huntersville, North Carolina laboratory. RESULTS Based on laboratory analysis, a detectable concentration of TPH-DRO was reported in soil sample SS-1; however, the concentration did not exceed the soil contamination action level established by NCDEQ. Laboratory analysis did not detect concentrations of TPH-GRO in soil sample SS-1. The laboratory report is included in Attachment C. CONCLUSIONS AND RECOMMENDATIONS Based on laboratory analysis of the soil sample collected near the 6,000-gallon premium spill bucket, no NCDEQ action levels were exceeded. AECOM, on behalf of Speedway recommends that this release be closed out with no further action. If you have any questions, please call Nicole Long, AECOM Project Manager, at (704) 649-6586. Sincerely, AECOM Heather Weston Nicole Long Environmental Scientist III Project Manager heather.weston@aecom.com nicole.long@aecom.com Marie Treiber Regional Senior Project Manager Marie.Treiber@aecom.com cc: Speedway Project File AECOM Site Check Report September 2023 Speedway 6975 Page 3 Raleigh, North Carolina Figure 1 Site Location Map Figure 2 Site Plan Attachments: A – UST-17A Form B – Soil Boring Log C – Laboratory Analytical Report AECOM Site Check Report September 2023 Speedway 6975 Page 4 Raleigh, North Carolina Professional Certification Page I, Brett G. Schaefer, a Licensed Engineer for AECOM Technical Services of North Carolina, Inc., do certify that the information contained in this report is correct and accurate to the best of my knowledge. _________________________________ Brett G. Schaefer, PE AECOM Technical Services of North Carolina, Inc. AECOM Technical Services of North Carolina, Inc. is licensed to practice engineering in North Carolina. The certification number of the company or corporation is F-0458. 2,0002,000 SITE LOCATION D. OLTEANU FIGURE 1SITE LOCATION MAP Source: Topo USGS 7.5 Minute Topographic Map Quadrangle: Raleigh East, NC Copyright: 2022 National Geographic Society DATE:DRAWN BY:REVIEWED BY:PROJECT NO.:Fil e : C : \ U s e r s \ O l t e a n u D \ A E C O M \ C o n v e n i e n c e S t o r e - 7 - E l e v e n \ N o r t h C a r o l i n a \ 4 6 8 7 6 - 6 9 7 5 R a l e i g h \ 4 6 8 7 6 - 6 9 7 5 R a l e i g h . d w g L a y o u t : S i t e L o c a t i o n M a p D a t e : 0 4 S e p , 2 0 2 3 X r e f s : 00 SCALE IN FEET: NOTE: ALL MAP FEATURES ARE APPROXIMATE IN SCALE AND LOCATION. N SEPTEMBER 2023 H. WESTON Speedway Store #6975 1741 Trawick Road Raleigh, North Carolina 27604 60713148 Speedway LLC. Canopy & Dispenser Islands Trash Enclosure Tank Field Vent Pipes Speedway Store #6975 Storm Water Retention Area Air Undeveloped Land Grass Bushes Concrete Asphalt Trees Trees Trees Trees T r a w i c k R o a d L a k e W o o d a r d D r i v e Shed A l l e y A l l e y Residential Complex Asphalt Parking Lot SS-1 #1 #3 #2 SCALE IN FEET: 30 300 DATE:DRAWN BY:REVIEWED BY:PROJECT NO.:C: \ U s e r s \ O l t e a n u D \ A E C O M \ C o n v e n i e n c e S t o r e - 7 - E l e v e n \ N o r t h C a r o l i n a \ 4 6 8 7 6 - 6 9 7 5 R a l e i g h \ 4 6 8 7 6 - 6 9 7 5 R a l e i g h . d w g , 9/ 1 1 / 2 0 2 3 1 2 : 4 5 P M , Olt e a n u , D a n , PD F 9 9 5 . p c 3 , Us e r 3 2 7 6 7 , 1'- 0 " = 1 ' - 0 " N D. OLTEANUSEPTEMBER 2023 H. WESTON FIGURE 2 SITE PLAN LEGEND Vent Line Storm Drain Communications Drainage Ditch NOTE: ALL MAP FEATURES ARE APPROXIMATE IN SCALE AND LOCATION. Speedway Store #6975 1741 Trawick Road Raleigh, North Carolina 27604 60713148 Speedway LLC. Unknown Utility Line Approximate Site Property Boundary Fence Product Dispenser Underground Storage Tank Utility Pole / Power Pole Light Post / Traffic Light Catch Basin / Stormwater Inlet Overhead Wire Buried Electric Line Water Line Product Piping Approximate Property Boundary Approximate Building Footprint 12,000-Gallon Diesel 12,000-Gallon RUL Gasoline 6,000-Gallon PUL Gasoline Soil Sample Location and IdentificationSS-1 Utility Manhole Transformer Water Meter ATTACHMENT A UST-17A FORM ATTACHMENT B SOIL BORING LOG --------- ------ SS-1 0.0 Hand auger RIG TYPE: N/A DEPTH TO WATER - OBSERVED IN BORING (feet): NA BORING DIAMETER: PROJECT NAME: Speedway 6975 PROJECT NUMBER: 60702558.010 SS-1 SITE LOCATION: 1741 Trawick Road, Raleigh, NC 27604 SHEET: 1 of 1 GENERAL LOCATION ON-SITE: Near the 6,000-gallon premium spill bucket DRILLING CONTRACTOR: Sweetwater DATE STARTED: 8/9/2023 DRILLING METHOD: Airknife DATE FINISHED: 8/9/2023 BORING DEPTH: 2.5 feet bgs Brown Compact Gravel & Silt Red/Brown Clayey Silt FIELD GEOLOGIST: Kade Porterfield WEATHER: 80s F, Partly Cloudy PRE-DIG METHODS: De p t h ( f t ) La b S a m p l e I D La b S a m p l e D e p t h ( f t . ) PI D R e a d i n g ( p p m ) Sa m p l i n g M e t h o d MATERIALS: Main component, additional components, color, moisture, plasticity, density/consistency, odor or other descriptive information --- 2.5 ft bgs --- 0-1' 1-2.5' 2.5' NOTES: Boring terminated at 2.5 feet bgs per scope of work for site check activities. Field Instrument QA/QC: Model & Serial Numbers - Mini Rae 3000 PID; 592-903314 Calibration Gas Lot #304-402472524 Red/Brown Clayey Silt Checked by: Nicole Long Date: 9/6/23 ATTACHMENT C LABORATORY ANALYTICAL REPORT #=CL# August 17, 2023 LIMS USE: FR - NICOLE LONG LIMS OBJECT ID: 92682125 92682125 Project: Pace Project No.: RE: Nicole Long AECOM 6000 Fairview Road, Suite 200 Charlotte, NC 28210 SPEEDWAY 6975 RALEIGH Dear Nicole Long: Enclosed are the analytical results for sample(s) received by the laboratory on August 10, 2023. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Bonnie Vang bonnie.vang@pacelabs.com Project Manager (704)875-9092 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 14 #=CP# CERTIFICATIONS Pace Project No.: Project: 92682125 SPEEDWAY 6975 RALEIGH Pace Analytical Services Charlotte South Carolina Laboratory ID: 99006 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Laboratory ID: 99006 South Carolina Certification #: 99006001 South Carolina Drinking Water Cert. #: 99006003 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana DoH Drinking Water #: LA029 Virginia/VELAP Certification #: 460221 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 14 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92682125 SPEEDWAY 6975 RALEIGH Lab ID Sample ID Matrix Date Collected Date Received 92682125001 SS-1 Solid 08/09/23 12:30 08/10/23 15:50 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 14 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92682125 SPEEDWAY 6975 RALEIGH Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92682125001 SS-1 EPA 8015C 2 PASI-CHH EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 14 #=HO# SUMMARY OF DETECTION Pace Project No.: Project: 92682125 SPEEDWAY 6975 RALEIGH Parameters AnalyzedResult Lab Sample ID Report Limit QualifiersUnitsMethod Client Sample ID 92682125001 SS-1 Diesel Range Organics(C10-C28)4.8J mg/kg 08/16/23 11:185.8EPA 8015C Percent Moisture 12.6 %08/10/23 17:27 N20.10SW-846 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 14 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92682125 SPEEDWAY 6975 RALEIGH Sample:SS-1 Lab ID:92682125001 Collected:08/09/23 12:30 Received:08/10/23 15:50 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)4.8J mg/kg 08/16/23 11:1808/14/23 16:375.8 4.1 1 Surrogates n-Pentacosane (S)70 %08/16/23 11:18 629-99-208/14/23 16:3710-133 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)ND mg/kg 08/13/23 00:4808/12/23 15:377.2 2.0 1 Surrogates 4-Bromofluorobenzene (S)101 %08/13/23 00:48 460-00-408/12/23 15:3766-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 12.6 %08/10/23 17:27 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/17/2023 01:55 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 14 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92682125 SPEEDWAY 6975 RALEIGH Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 793258 EPA 5030B EPA 8015C Gasoline Range Organics Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92682125001 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:4110689 Associated Lab Samples:92682125001 Matrix:Solid AnalyzedMDL Gas Range Organics (C6-C10)mg/kg ND 6.0 08/12/23 18:461.7 4-Bromofluorobenzene (S)%100 66-130 08/12/23 18:46 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 4110690LABORATORY CONTROL SAMPLE: LCSSpike Gas Range Organics (C6-C10)mg/kg 51.549.7 104 70-130 4-Bromofluorobenzene (S)%102 66-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 4110692MATRIX SPIKE SAMPLE: MSSpike Result 92681470002 Gas Range Organics (C6-C10)mg/kg 78.181.9 95 57-154ND 4-Bromofluorobenzene (S)%103 66-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92681470001 4110691SAMPLE DUPLICATE: Gas Range Organics (C6-C10)mg/kg ND 30ND 4-Bromofluorobenzene (S)%100101 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/17/2023 01:55 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 14 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92682125 SPEEDWAY 6975 RALEIGH Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 793416 EPA 3546 EPA 8015C 8015 Solid GCSV Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92682125001 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:4111352 Associated Lab Samples:92682125001 Matrix:Solid AnalyzedMDL Diesel Range Organics(C10-C28)mg/kg ND 5.0 08/16/23 10:153.6 n-Pentacosane (S)%66 10-133 08/16/23 10:15 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 4111353LABORATORY CONTROL SAMPLE: LCSSpike Diesel Range Organics(C10-C28)mg/kg 54.766.9 82 43-130 n-Pentacosane (S)%71 10-133 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 4111354MATRIX SPIKE SAMPLE: MSSpike Result 92682241001 Diesel Range Organics(C10-C28)mg/kg 774 M190.3 541 15-130286 n-Pentacosane (S)%77 10-133 Parameter Units Dup Result Max RPD QualifiersRPDResult 92682436004 4111355SAMPLE DUPLICATE: Diesel Range Organics(C10-C28)mg/kg 4.6J 307.4 n-Pentacosane (S)%7383 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/17/2023 01:55 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 14 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92682125 SPEEDWAY 6975 RALEIGH Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 792819 SW-846 SW-846 Dry Weight/Percent Moisture Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92682125001 Parameter Units Dup Result Max RPD QualifiersRPDResult 92681878001 4108647SAMPLE DUPLICATE: Percent Moisture %20.8 N202520.8 Parameter Units Dup Result Max RPD QualifiersRPDResult 92682125001 4108879SAMPLE DUPLICATE: Percent Moisture %13.7 N282512.6 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/17/2023 01:55 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 14 #=QL# QUALIFIERS Pace Project No.: Project: 92682125 SPEEDWAY 6975 RALEIGH DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.M1 The lab does not hold NELAC/TNI accreditation for this parameter but other accreditations/certifications may apply. A complete list of accreditations/certifications is available upon request.N2 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/17/2023 01:55 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 14 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92682125 SPEEDWAY 6975 RALEIGH Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92682125001 793416 793862SS-1 EPA 3546 EPA 8015C 92682125001 793258 793266SS-1 EPA 5030B EPA 8015C 92682125001 792819SS-1 SW-846 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 08/17/2023 01:55 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 14 Page 12 of 14 Page 13 of 14 Page 14 of 14