Loading...
HomeMy WebLinkAboutMO-86743_86743_C_MISCCLO_20231207AECOM Technical Services of North Carolina, Inc.919-461-1100 phone 5438 Wade Park Boulevard, Suite 200 919-461-1415 fax Raleigh, North Carolina 27607 December 6, 2023 Ryan Mills North Carolina Department of Environmental Quality Division of Waste Management, UST Section Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 Subject:Monitoring Well Abandonment Report Products (SE) Pipe Line Corporation – Salisbury Pump Station 1615 Jake Alexander Boulevard West Salisbury, Rowan County, North Carolina 28056 NCDEQ Incident Number: 86743 NCDEQ Risk Classification: Low Dear Mr. Mills: On behalf Products (SE) Pipe Line Corporation (PPL), AECOM Technical Services of North Carolina, Inc. (AECOM) respectfully submits the attached monitoring well abandonment documentation associated with the above referenced Site. AECOM self-performed monitoring well abandonment activities, under the supervision of an in-house North Carolina licensed drilling contractor. PPL has elected to retain monitoring wells MW-7, MW-8, MW-15 and MW-18 due to this being an active facility. Should there be any issues, the wells will be beneficial for monitoring impacts, all other monitoring wells were abandoned by AECOM at the Salisbury Pump Station Site. Monitoring well construction details are presented in Table 1 and a site map is provided as Figure 1. Select monitoring wells were abandoned using a cement slurry introduced from the bottom of the well to the ground surface using a tremie pipe. Deeper monitoring wells (MW-14I, MW-18D, and MW-19) were abandoned using bentonite pellets. The concrete pad and protective well covers were removed from the ground and the Site was restored to the previous condition. The well abandonment activities were performed in accordance with 15A NCAC 02C .0113 and the Notice of No Further Action Letter received on May 1, 2023. Well abandonment records (Form GW-30) can be found as an attachment. If you have any questions regarding this project, please contact me at 704-907-1354 or brandt.morrow@aecom.com or Angela Scott with PPL at 770-751-4252. Sincerely, AECOM Technical Services of North Carolina, Inc. Brandt Morrow, PG Project Manager cc: Angela Scott, PPL (electronic) AECOM Project File (electronic) Well ID Date Installed (feet bgs) Well Diameter (inches) Screened (feet bgs) Top-of-Casing (feet amsl) MW-1 11/15/04 15 2 1-15 694.42 MW-2 11/15/04 15 2 2-15 693.23 MW-3 11/15/04 15 2 2-15 693.48 MW-4 11/15/04 15 2 2-15 693.54 MW-5 11/16/04 15 2 2-15 694.18 MW-6 11/15/04 15 2 2-15 692.62 MW-7 11/15/04 15 2 3-15 692.81 MW-8 11/16/04 15 2 1-15 693.61 MW-9 11/15/04 15 2 2-15 695.54 MW-10 11/16/04 15 2 2-15 694.14 MW-11 11/16/04 15 2 2-15 693.23 MW-12 11/15/04 15 2 2-15 693.56 MW-13 11/16/04 15 2 2-15 693.28 MW-14 11/16/04 15 2 2-15 694.31 MW-14I 11/16/04 25 2 10-25 694.06 MW-15 11/16/04 15 2 2-15 693.85 MW-16 11/15/04 15 2 2-15 692.50 MW-17 11/15/04 15 2 2-15 693.56 MW-18 10/31/05 15 2 3-15 694.05 MW-18D*11/01/05 38 2 32-37 694.11 MW-19 02/01/06 70 2 60-70 694.50 Notes: Monitoring wells in grey were abandoned on October 3, 2023. amsl - above mean sea level bgs - below ground surface * - MW-18D was constructed as a Type III monitoring well, with a 6-inch poly vinyl chloride surface casing installed to 30 feet bgs. Salisbury, Rowan County, North Carolina Table 1 Monitoring Well Construction Details Products (SE) Pipe Line Corporation Salisbury Pump Station 1615 Jake Alexander Boulevard West JA K E A L E X A N D E R B O U L E V A R D ASPHA L T D R I V E GRAVE L LEGEND Designed by: EL Checked by: BM Approved by: WPFilename: C:\USERS\LORENTE\AECOM\GDS GIS SERVICES - GIS CAD PROJECTS\DCS AMERICAS\KINDER MORGAN\SALISBURY\WORKSPACE\20231102\FIGURE 1_02112023.DWG WELL ABANDONMENT REPORT PRODUCTS (SE) PIPE LINE CORPORATION - SALISBURY PUMP STATION SALISBURY, ROWAN COUNTY, NORTH CAROLINA Project Number: 60698141 Date: 2023-11-01 SITE MAP Figure: 1 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.04 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6819354 -80.5078785 MW-1 15.0 2.0 8.65 N/A 1.0 14.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.66 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6817472 -80.5081310 MW-2 15.0 2.0 4.80 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.42 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6817328 -80.5083382 MW-3 15.0 2.0 6.28 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.40 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6815625 -80.5082232 MW-4 15.0 2.0 6.42 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.21 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6815865 -80.5080422 MW-5 15.0 2.0 7.57 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.23 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6812790 -80.5081210 MW-6 15.0 2.0 7.48 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.11 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6819487 -80.5077022 MW-9 15.0 2.0 8.22 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.59 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6817989 -80.5078494 MW-10 15.0 2.0 5.25 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.52 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6816927 -80.5081967 MW-11 15.0 2.0 5.70 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.39 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6815263 -80.5083613 MW-12 15.0 2.0 6.48 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.43 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6814803 -80.5082044 MW-13 15.0 2.0 6.23 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.17 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6815157 -80.5080680 MW-14 15.0 2.0 7.84 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 2.79 AECOM Technical Services of North Carolina N/A N/A N/A Bentonite Chips- 50 lbs Water-1.00 gallons October 03, 2023 Slowly filled Monitoring Well to within 1 foot of surface while checking for bridging. Topped off with Concrete. The well was abandoned in accordance with 15A NCAC 02C .0113" Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6814051 -80.5079359 MW-14I 25.0 2.0 7.88 N/A 10.0 15.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.39 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02 C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6813147 -80.5083010 MW-16 15.0 2.0 6.49 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 1.16 AECOM Technical Services of North Carolina N/A N/A N/A Portland-27.07 pounds Water-2.00 gallons Bentonite-1.13 pounds October 03, 2023 Tremie grouted with a portland mix. The well was abandoned in accordance with 15A NCAC 02 C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6814051 -80.5079359 MW-17 15.0 2.0 7.91 N/A 2.0 13.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 4.06 AECOM Technical Services of North Carolina N/A N/A N/A Bentonite Chips- 74 lbs Water-1.00 gallons October 03, 2023 Slowly filled Monitoring Well to within 1 foot of surface while checking for bridging. Topped off with Concrete. The well was abandoned in accordance with 15A NCAC 02C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6813986 -80.5073847 MW-18D 37.0 2.0 12.11 30.0 32.0 5.0 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Frank Beecher 3225-A N/A 8.73 AECOM Technical Services of North Carolina N/A N/A N/A Bentonite Chips- 140 lbs Water-1.00 gallons October 03, 2023 Slowly filled Monitoring Well to within 1 foot of surface while checking for bridging. Topped off with Concrete. The well was abandoned in accordance with 15A NCAC 02 C .0113". Products (SE) Pipeline Corporation N/A 1615 Jake Alexander Boulevard West, Salisbury, 28147 October 30, 2023 Rowan 450 011 35.6813986 -80.5073847 MW-19 70.0 2.0 16.53 N/A 60.0 10.0