Loading...
HomeMy WebLinkAboutFA-3270_29451_CA_WR_20240509_MWs Abandonment1044 Washington Street Raleigh, NC 27605 (919) 838-2875 www.CatlinUSA.com Wilmington, NC | Raleigh, NC | Washington, NC | Atlanta, GA E N V I RO N M E N TA L | C I V I L | G E O T E C H N I C A L Wilmington, NC | Raleigh, NC | Washington, NC | Atlanta, GA | Charleston, SC May 9, 2024 North Carolina Department of Environmental Quality Division of Waste Management UST Section Attn: Mr. Hassan Osman 1646 Mail Service Center Raleigh, NC 27699-1646 Re: Letter Report – Well Abandonment Community Stop #2 150 West Doctor Martin Luther King Junior Drive Maxton, North Carolina 28364 Incident Number: 29451 Risk Classification: I170A CATLIN Project No. 223228.03 Dear Mr. Osman, CATLIN Engineers and Scientists (CATLIN) is pleased to provide you with this letter report documenting well abandonment field activities performed in general accordance with CATLIN proposal number 223228.03P, prepared March 13, 2024. Services were authorized by the North Carolina Department of Environmental Quality (NCDEQ) Task Authorization (TA) #03, accepted March 19, 2024, and Contract Number N70522-A. The approved scope of services for this Task Authorization included: • Abandon seventeen (17) monitoring wells (MW-1 through MW-16, and TW-1); and • Prepare a letter report documenting the site activities. Monitoring Well Abandonment On April 17, 2024, CATLIN personnel mobilized to the site and abandoned monitoring wells MW-1 through MW-9, MW-11 through MW-16, and TW-1. CATLIN searched for monitoring well MW-10 using a ground probe and a metal detector; however, this well could not be located. Well construction information for the abandoned wells is provided in the following table: May 9, 2023 Page 2 of 3 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 Well ID Well Type Well Depth (feet) Well Diameter (inches) Abandonment Procedure MW-1 Shallow 20.0 2.0 All well materials left in place MW-2 Shallow 16.0 2.0 All well materials left in place MW-3 Shallow 16.0 2.0 All well materials left in place MW-4 Shallow 15.0 2.0 Concrete and well shield removed. MW-5 Shallow 15.0 2.0 Concrete and well shield removed. MW-6 Shallow 15.0 2.0 Concrete and well shield removed. MW-7 Shallow 15.0 2.0 All well materials left in place MW-8 Shallow 15.0 2.0 All well materials left in place MW-9 Shallow 15.0 2.0 Concrete and well shield removed. MW-11 Shallow 15.0 2.0 Concrete and well shield removed. MW-12 Shallow 15.0 2.0 Concrete and well shield removed. MW-13 Shallow 15.0 2.0 Concrete and well shield removed. MW-14 Shallow 15.0 2.0 Concrete and well shield removed. MW-15 Shallow 15.0 2.0 All well materials left in place MW-16 Shallow 22.0 2.0 All well materials left in place TW-1 Deep 50.0 2.0 All well materials left in place Monitoring wells MW-1 through MW-9, MW-11 though MW-16, and TW-1 were abandoned by a North Carolina Certified Well Contractor (CWC) according to guidance provided in the North Carolina Administrative Code (NCAC) Title 15A 02C .0113 (Abandonment of Wells). All well materials were abandoned in place and packed with bentonite chips to within six inches of the surface while simultaneously pouring water to facilitate hydration. The remaining space was filled with concrete (MW-1, MW-2, MW-3 MW-7, MW-8, MW-15, MW-16 and TW-1) or topsoil (MW-4, MW-5, MW-6, MW-9, MW-11, MW-12, MW-13, and MW-14) to the existing grade. May 9, 2023 Page 3 of 3 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 The site vicinity and well locations are shown on Figures 1 and 2, respectively (Attachment A). The well abandonment records were previously submitted to the NCDEQ Division of Water Quality under separate cover, and a copy is provided in Attachment B. Photographs of the abandoned wells are included in Attachment C. CATLIN Engineers and Scientists appreciates this opportunity to be of service. Should you have any questions or require additional information, please contact us at (919) 838- 2875. Sincerely, Sean J. O’Neil, PE Project Manager Attachments: A: Figures B: Well Abandonment Records C: Site Photographs FA-3270_29451_CA_LTRRPT_20240509_Well Abandonment NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 ATTACHMENT A FIGURES FLORENCE ST W MARTIN LUTHER KING JR DR SITE LOCATION Copyright:© 2013 National Geographic Society, i-cubed 2,000 0 2,000 4,0001,000 Feet ³ FIGUREPROJECTTITLE 1 COMMUNITY STOP #2 150 W MARTIN LUTHER KING JR DR MAXTON, NC SITE VICINITY MAP INCIDENT NO.JOB NO.DATE SCALE DRAWN BY/CHECKED BY29451223228MAY 2024 AS SHOWN KMC/SJO !( !( !( !>!(> !> !> !> !> !>!> !> !> !> !> !> !> !> !> !> FLO R E N C E S T W MARTIN L U T H E R K I N G J R D R CURRENT DISPENSERS FORMERDISPENSERS 12,000-GAL.GASOLINE USTS10,000-GAL.GASOLINE UST10,000-GAL.DIESEL UST 10,000-GAL.KEROSENE UST MW-6 MW-7 MW-9 MW-8 MW-5 MW-4 MW-3 MW-2 TW-1MW-1 MW-15 MW-10(CNL) MW-14 MW-13 MW-12 MW-11 MW-16 Source: Esri, Maxar, Earthstar Geographics, and the GIS User Community 60 ³ FIGUREPROJECTTITLE 2 INCIDENT NO.JOB NO.DATE SCALE DRAWN BY/CHECKED BY !> !(> LEGEND !> NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 ATTACHMENT B WELL ABANDONMENT RECORDS WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Concrete 35 lbs 25 lbs 4/17/2024 All well materials abandoned in place using hydrated bentonite to approximately six inches below land surface. Concrete was used to bring remaining opening to grade.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-1 20 8.25 5.84 Unknown 5 15 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Concrete 30 lbs 25 lbs 4/17/2024 All well materials abandoned in place using hydrated bentonite to approximately six inches below land surface. Concrete was used to bring remaining opening to grade.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-2 16 8.25 4.99 Unknown 6 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Concrete 30 lbs 25 lbs 4/17/2024 All well materials abandoned in place using hydrated bentonite to approximately six inches below land surface. Concrete was used to bring remaining opening to grade.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-3 15 8.25 6.04 Unknown 6 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Soil 25 lbs 25 lbs 4/17/2024 Well was abandoned using hydrated bentonite to approximately 6 inches below land surface. Concrete and well shield removed and topsoil used to bring opening to grade.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-4 15 8.25 4.89 Unknown 5 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Soil 25 lbs 25 lbs 4/17/2024 Well was abandoned using hydrated bentonite to ~6 inches below land surface. Concrete and well shield removed. Topsoil used to bring opening to grade.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-5 15 8.25 5.34 Unknown 5 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Soil 25 lbs 25 lbs 4/17/2024 Abandoned well using hydrated bentonite to approximately 6 inches below land surface. Topsoil used to bring opening to grade after removal of the concrete and well shield.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-6 15 8.25 4.88 Unknown 5 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Soil 25 lbs 25 lbs 4/17/2024 Abandoned well using hydrated bentonite to ~6 inches below land surface. Concrete and well shield removed and the remaining opening brought to grade using topsoil.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-7 15 8.25 4.95 Unknown 5 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Soil 25 lbs 25 lbs 4/17/2024 Abandoned well using hydrated bentonite to ~6 inches Below land surface. Concrete and well shield removed and filled the remaining opening to grade using topsoil.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-8 15 8.25 4.84 Unknown 5 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Soil 25 lbs 25 lbs 4/17/2024 Abandoned well using hydrated bentonite to ~6 inches below land surface. Concrete and well shield removed and then remaining opening brought to grade using topsoil.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-9 15 8.25 7.53 Unknown 5 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Soil 25 lbs 25 lbs 4/17/2024 Abandoned well using hydrated bentonite to ~6 inches below land surface. Concrete and well shield removed and the remaining opening was brought to grade using topsoil.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-11 15 8.25 5.31 Unknown 5 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Soil 25 lbs 25 lbs 4/17/2024 Abandoned well using hydrated bentonite to ~6 inches below land surface. Concrete and well shield removed and then opening was brought to grade using topsoil.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-12 15 8.25 4.98 Unknown 5 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Soil 25 lbs 25 lbs 4/17/2024 Abandoned well using hydrated bentonite to ~6 inches below land surface. Concrete and well shield removed and the remaining opening brought to grade using topsoilNic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-13 15 8.25 6.12 Unknown 5 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Soil 25 lbs 25 lbs 4/17/2024 Abandoned well using hydrated bentonite to ~6 inches below land surface. Concrete and well shield removed and the remaining opening brought to grade using topsoil.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-14 15 8.25 7.04 Unknown 5 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Concrete 25 lbs 25 lbs 4/17/2024 All well materials abandoned in place using hydrated bentonite to approximately six inches below land surface. Concrete was used to bring remaining opening to grade.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-15 15 8.25 6.05 Unknown 5 10 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Concrete 25 lbs 25 lbs 4/17/2024 All well materials abandoned in place using hydrated bentonite to approximately six inches below land surface. Concrete was used to bring remaining opening to grade.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 MW-16 22 8.25 5.56 Unknown 2 20 WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. 4/19/2024 Nathaniel Newman 4630C CATLIN Engineers and Scientists Bentonite Concrete 70 lbs 25 lbs 4/17/2024 All well materials abandoned in place using hydrated bentonite to approximately six inches below land surface. Concrete was used to bring remaining opening to grade.Nic's Properties, Inc.00-0-0000018540 150 West Martin Luther King Jr. Drive Robeson 839549600700 34.736059 -79.350995 TW-1 50 8.25 13.63 Unknown 45 5 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 ATTACHMENT C SITE PHOTOGRAPHS ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-1 after abandonment. View of MW-2 after abandonment. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-2 finished. View of MW-3 after abandonment. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-3 finished. View of MW-4 after abandonment. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-4 finished. View of MW-5 after abandonment. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-5 finished. View of MW-6 after abandonment. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-6 finished. View of MW-7 after abandonment. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-7 finished. View of MW-8 finished. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-9 after abandonment. View of MW-9 finished. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-11 after abandonment. View of MW-11 finished. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-12 after abandonment. View of MW-12 finished. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-13 after abandonment. View of MW-13 finished. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-14 after abandonment. View of MW-14 finished. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-15 after abandonment. View of MW-15 finished. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of MW-16 after abandonment. View of MW-16 finished. ATTACHMENT C SITE PHOTOGRAPHS – MARCH 17, 2024 NCDEQ; 29451_Community Stop #2 CATLIN Engineers and Scientists CATLIN Project No. 223228 May 2024 View of TW-1 after abandonment. View of TW-1 finished