Loading...
HomeMy WebLinkAbout6301_MooreCounty_MSWLF_CDLF_Feb2023LFG_FID1831870_20240311I pENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: C DENR Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: • Prepare one form for each individually monitored unit. • Please type or print legibly. • Attach a notification table with values that attain or exceed NC 2L groundwater standards or INC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). • Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. • Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 136 .1629 (4)(a)(i). • Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): S&ME, Inc. (on behalf of Moore County) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Edmund Q.B. Henriques Phone: 336-288-7180 E-mail: ehendques@smeinc.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) February 22, 2024 Moore County Landfill::1 456 Turning Leaf Way, Aberdeen, INC 63-01 .0500 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring E Detection Monitoring of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells �x Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data ❑ Surface water monitoring data ❑ Assessment Monitoring Methane gas monitoring data Corrective action data (specify) Corrective Action Other(specify) Pilot Test Well Methane Data Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. Q x Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Edmund Q.B. Henriques, PG Senior Geologist, S&ME Inc. 336-312-3330 Facility Representative Name (Print) A Title (Area Code) Telephone Number 3/5/2024 Affix NC LicgU"(6flF9gssional Geologist Seal Signature "N I Date 8646 W. Market Street, Suite 105, Greensboro NC 27409 Facility Representative Address F-0176 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 1216 w PW-1 BLAKE RESIDENCE (CRAWL SPACE MONITORED) Q7 "V III OMW 5 Q` • • • • ♦ 'GP-17 • •'GP 18 W-15R � • � �` • �-•GV-34 Vs • • • — — ♦ GV 33 GV-40 GV-41. GP-19 GV-39 • • MW-11SR MW-11DR V ♦�I•�.•—� 1 GV-3, GV-38—tr \ \ \ _SW-4 \ \ GP-15R \ MW 17S MW-1' \ \ GP-14 \ MW`19 �v mvv-io I I I I i GP-12 � MW-3 � O �u 0 400 r8OO (FEET) Note: THIS MAP IS FOR INFORMATIONAL PURPOSES ONLY. ALL FEATURE LOCATIONS DISPLAYED ARE APPROXIMATED. THEY ARE NOT BASED ON CIVIL SURVEY INFORMATION, UNLESS STATED OTHERWISE. OMW-14 MW-14 O O MW-6 29 28 27 T '�GP-"GP O 26 25 S 4 3 2 1 11 10 9 8 7 12 GV-35 GV-36 17 18 19 20 21 22 23 24 MW-8 \AW= woo. ♦ MAINTENANCE SHOP ♦ MW-9 ♦ O GP-11 ♦ ♦ r r r— TRANSFER STATION OFFICE MWp-1' , 01 MW-2 O , 0 — • PARCEL BOUNDARY — — APPROXIMATE LIMITS OF WASTE — — MSW LANDFILL COMPLIANCE BOUNDARY — — C&D LANDFILL COMPLIANCE BOUNDARY — Stream — — — — — — — — — — — — — — — — — — — — — — — — — — — O MONITORING WELL GV-32 �GV-31 GV-30 CLOSED MSW LANDFILL / I , GP-10R / r � SCALEHOUSE �r SCALE: 4* 1 " = 400' DATE: FEBRUARY 2024 PROJECT NUMBER PASSIVE LANDFILL GAS VENTS 4358-20-043 *+ LANDFILL GAS TRENCH VENT FIGURE NO. - METHANE PROBES ® WATER SUPPLY WELL _ APPROXIMATE LIMITS OF WASTE Table 1 Summary of Methane Gas Readings 2020 - 2023 Moore County Landfill (Permit 63-01) Moore County, North Carolina S&ME Project No. 4358-20-043A Location Scale- house g Point Type • 7 02/17/20 0.0% Maintena Shop • 0.0% Station ONSS 0.0% Blake Crawlspace • 0.0% GP-9 0.0% r footn tel# 18.7% WUFMl! not installed 0.0% 0.0% 111 0.0% 0.0% 0.0% G P, 0.0% �GP11 footnote#2 0.0% 1116PBI 0.0% 0.0% 0.0% MW-6 footnote#1 11.9% MW-15/ Al 28.1% GP-19 not installed r footnote#4 not installed NEGEMEM footnote#4 not installed 04/07/20 0.0% 0.0% 0.0% 0.0% 0.0% 32.2% not installed 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.4% 23.6% 59.9% not installed not installed not installed 09/15/20 0.1% 0.0% 0.0% 0.0% 0.1% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 0.0% 22.5% 0.0% not installed not installed 12/14/20 0.0% 0.0% 0.0% 0.1% 0.1% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.5% 9.6% 61.3% 0.0% not installed not installed 02/24/21 0.0% 0.0% 0.0% NM 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.4% 28.7% 67.9% 0.0% not installed not installed 04/12/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.2% 2.0% 21.8 % 0.0% not installed not installed 09/29/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.0% 19.5% 57.5% 0.0% not installed not installed 12/17/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 13.8% 27.8% 0.0% 10.1% 57.0% 03/25/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 29.1% 54.7% 0.0% 28.1% 56.4% 06/06/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 4.7% 42.4% 0.0% 30.5% 56.5% 09/26/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.1% 9.5% 50.8% 0.0% 13.7% 56.1% 12/16/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 2.9% 13.8% 56.5% 0.0% 27.4% 51.4% 03/28/23 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.4% 6.9% 38.7% 0.0% 40.1% 31.8% 06/08/23 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.4% 22.0% 49.9% 0.0% 36.8% 31.8% 09/20/23 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 13.2% 36.7% 12/15/23 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 7.0% 26.1% 0.0% 0.0% 56.3% 02/22/24 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 1 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 17.8% 40.3% 0.0% 23.9% 59.2% Notes: Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure Footnote#1 = MW-6 was replace by GP-19 as the property boundary compliance point. MW-6 is approximately 150 feet inside the property boundary and not a compliance point. Footnote#2 = GP-10 was replaced by GP-10R, GP-13 replaced by GP-13R, GP-14 replaced by GP-14R, GP-15 replaced by GP-15R Footnote#3 = Groundwater monitoring well MW-15 converted to gas monitoring point now identified as GP-18, which is a property boundary compliance point. Footnote#4 = Gas monitoring points installed for a cancelled active gas extraction pilot test. A new passive venting pilot test has been proposed. all measurements recorded in percent methane by volume Lower explosive limit of methane gas: 5% Upper explosive limit of methane gas: 15% Data recorded prior to 9/15/20 obtained by Golder not installed = Well not installed at the time of monitoring Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point Orange highlight cells and values in bold print indicate methane percent by volume greater than or equal to 1.25% inside structures. T:\Greensboro-1s80\Projects\2020\4358-2-A Moore-W Routine - & WQ MonRoring\h. 08- Quarterly Methane Monitoring 202-24\LFG Re dmje Tables-<M1an NPROGRESS.rcIe, 2/2SI.. Table 2 Historic Methane Readings At Gas Compliance Points and Passive Vents GV-33 through GV-41 Moore County Landfill (Permit No. 63-01) Aberdeen, North Carolina S&ME Project No. 4358-20-043A, Phase 06 R GI-111MMOMMMMMMMO GP11JWMJGV-35 GV-36 GV-37 GV-38 GV-39 GV-40 GV-41 T:\G...b..-Ia P,.j.,1\2020\43S8-2o43AM.r.m..nn.b..LFG&WQM..nori.,\Ph..N-Q�.mrl,M..n.M.n� rin,roz 2024\LFGR.•di.,,bl....dCh.ft N—GRESS.A. Table 2 Historic Methane Readings At Gas Compliance Points and Passive Vents GV-33 through GV-41 Moore County Landfill (Permit No. 63-01) Aberdeen, North Carolina S&ME Project No. 4358-20-043A, Phase 06 6 lxz� TMEW. MOM, L /14/13 0.0% 0.0% 0.0% 0.7% 0.4% 0.0% 0.0% 2.2% 58.9% -2�1 1 04/16/13 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.1% 18.3% 7/30/13 0 0, 0.0% 0.0% 0.0% 0.2% 0.2% 0.2% 0.2% 6.9% 57.9% 10/01/13 0.0% 0.0% 0.0% 0.0% 0.0%1 0.0% 0.0% 5.6% 64.8% 02/11/14 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 2.0% 0.5% 0.2% 04/17/14 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.5% 08/25/14 0.0%1 0.0% 0.0%1 --1 0.0% 0.0% 0.0% 0.0% 0.0% 54.0% 10/16/14 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 2.3% 58.3% 01/16/15 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 55.9% 04/21/15 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.7% 08/17/15 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 51.8% 01/28/16 0.0% 0.0% 0.0% 0.1% 0.0% 0.1% 0.1% 0.1% 49.6% 04/11/16 0.0% 0.0%, 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 10.6% 08/05/16 0.0% 0.0% 0.0% 0.0%1 0.2% 0.2% 0.2% - 0.2% 2.5% 60.2% 12/02/16 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% - 0.0% 0.0% 0.7% 02/09/17 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% - 0.0% 0.0% 0.0% 04/12/17 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% - 0.0% 0.4% 29.1% 08/16/17 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% - 0.0% 1.6% 28.9% 12/12/17 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% - 0.0% 0.0% 9.1% 01/22/18 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% - 0.0% 0.0% 53.5% 06/20/18 0.0% 0.0% 0.0% 0.0%1 0.0% 0.0% 0.0%1 - 0.0% 1.0% 54.6%, 08/23/18 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% - 0.0% 0.6%1 16.2% 11/28/18 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 8.1% 46.5% 1.4% 02/13/19 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 20.7% 0.0% 0.0% 04/03/19 0.1% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.6% 9.1% 7.0% 09/26/19 0.0%1 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.7% 55.5% 35.1% 9.0% 11/20/19 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 18.6% 4.9% 0.2% 02/17/20 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0%1 0.0%1 0.0% 0.0% 28.1%1 35.9%1 0.3% 04/07/20 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.4% 59.9% 42.0% 9.0% 09/15/20 0.1% 0.0% 0.0% 0.0% 0.1% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 22.5% 25.0% 22.1% 12/11/20 0.0% 0.0% 0.0% 0.0% 0.1% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.5% 0.0% 61.3% 45.0% 52.2% 02/24/21 0.0% 0.0% 0.0% 0.0% 0.1% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 1.4% 0.0% 67.8% 44.5% 51.4% 04/12/21 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 1.2% 0.0% 21.8% 39.5% 36.1% 09/29/21 1 0.0%1 0.0%1 0.0%1 0.0%1 0.0%1 0.0% 0.0%1 0.0% 0.0%1 0.0% 0.0% 0.0%1 1.0% 0.0%1 57.5% 55.6% 46.8% 1 12/17/ 1 1 0.0%1 0.0%1 0.0%1 0.0%1 0.0%1 0.0%1 0.0%1 0.0%1 0.0o/,F 0.09/61 0.0%1 0.0%1 0.0%1 0.0%1 27.8%1 10.1% 57.09/61 34.3%1 46.6% T:\G..b..-Ia P,.j.,1\2020\43S8-2o43AM.,.�.�w .b..LFG&WQM..n li.,\Ph..N-0�am11,Men,M..noli.,rov2o24\LFGadi.,.bl....dCh.ft N-GRESS.A. Table 2 Historic Methane Readings At Gas Compliance Points and Passive Vents GV-33 through GV-41 Moore County Landfill (Permit No. 63-01) Aberdeen, North Carolina S&ME Project No. 4358-20-043A, Phase 06 i 03/25/22 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 54.7% 28.1 % 56.4 % 53.7 % 51.6 % -- - -- -- -- - -- 16/07/22 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 42.4% 30.5% 56.5% 49.1% 50.7% -- - -- - -- - -- O6/16/22 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM 58.4% 54.9% -- - -- - -- 06/17/22 NM NM NM NM NM NM NM NM NM NM NM NM NM NM 21.1% 21.3%1 57.6%1 52.4% 58.1% 57.2% 57.3% -- - -- - -- 09/26/22 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.1 % 0.0% 50.8% 13.7% 56.1 % 52.5 % 47.9% 55.6 % 56.2 % - - -- - -- 12/16/22 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 2.9% 0.0% 56.5% 27.4% 51.4% 54.2% 47.6% 56.4% 57.0% -- -- -- - -- 03/28/23 0.0%1 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.4% 0.0% 38.7% 40.1% 31.8% 35.7% 49.8% 26.4%1 46.7% -- - -- - -- 06/08/23 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.4% 0.0% 49.9% 36.8% 57.1% 54.5% 54.9% 57.7% 57.7% -- - -- - -- 09/20/23 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.4% 0.0% 0.0% 13.2% 36.7% 46.9% 40.8% 13.6% 22.4% -- - -- -- -- 12/15/23 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.4% 0.0% 26.1% 0.0% 56.3% 40.3% 38.2% 37.4% 43.9% -- -- - -- -- 02/22/24 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0%1 40.3% 0.0% 59.2% 49.5%1 49.9% 57.5% 59.1% 55.3% 57.9%1 59.0% 57.7%158.4% Notes: - Gas probes with GP prefix installed March 2000, except GP-20 & GP-21 install October 2021. GV 1-12 installed in November 2004. GV 13-24 installed in November 2007. GV 25-29 installed in February 2009. GV 30-33 installed April 2014 GV 33 & GV-34 installed November 2018 (gas cut-off trench) 100% GV-35 & GV-36 installed June 2022 90% GV-37 through GV-41 installed February 22, 2024 80% NM = not measured 70% Lower explosive limit of methane gas: 5 % 60% Upper explosive limit of methane gas: 15% 50% Indicates methane gas levels between upper and lower explosive limit. 40% Indicates methane gas levels above upper explosive limit. 30% All data recorded prior to 0810812007 supplied by HDR. 20% All data recorded prior to 9115120 supplied by Golder to% -- May indicate a reading of zero OR no record. 0% METHANE (%) @ MW-15/GP-18 OC OC O� O� 09 09 09 09 'y0 'y0 ,1'Y titi titi 1ti 'Y"i ya ya ya yb 'yh 'yb 'y6 'y� 'y� 'y0 'y0 'y9 'y9 green shading indicates a compliance gas monitoring well replaced with new well orange shading =vent wells that are not compliance wells a yellow shading = active compliance monitoring wells with LEL > 5 % light yellow shading = gas monitoring points installed for pilot test r\c.n.b..-I a P,o;.«\2020\43se-2o 43RM.r.�nnwR.b..Lw E'wu Mann ri.,\vhauN-main,Me .ne Mannorm,roz 2o24uw Reading bl.,and Ch.ft N-GRE33.au NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: 02/22/2024 NC Landfill Rule (.0500 or.1600): 0.0500 Sample Collector Name & Position: Edmund Henriques / Senior Geologist (S&ME, Inc.) Gas Meter Type & Serial Number: GEM 5000 Plus / G507520 Field Calibration Date & Time: 2/16/2024 Gas Meter Calibration Date: 5/9/2023 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 1/1/28 Gas Meter Pump Rate: 703 cm/min Ambient Air Temperature: 60 F Barometric Pressure (in. or mm Hg): 29.59 Weather Conditions: Sunny Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) x 20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial /o LEL Stabilized /o LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES GP-9 60 1314 120 0.0 0.0. 0.0 20.1 1.11 0.0 Property Boundary Monitoring Pt. GP-1 OR 1 60 1259 120 1 0.0 0.0 0.0 18.9 1 1.8 0.0 Property Boundary Monitoring Pt. GP-1 1 60 1247 120 0.0 0.0 0.0 15.1 3.8 0.0 Property Boundary Monitoring Pt. G P-12 60 1139 120 0.0 0.0 0.0 20.4 0.4 0.0 Property Boundary Monitoring Pt. GP-1 3R 60 1122 120 0.0 0.0 0.0 20.2 0.7 0.0 Property Boundary Monitoring Pt. G P 14 R 60 1114 120 0.0 0.0 0.0 18.2 2.5 0.0 Property Boundary Monitoring Pt. GP-1 5R 60 1105 120 0.0 0.0 0.0 20.1 1.1 0.0 Property Boundary Monitoring Pt. GP-1 6 60 1054 120 0.0 0.0 0.0 9.4 12.2 0.0 Property Boundary Monitoring Pt. GP-1 7 60 1046 120 0.0 0.0 0.0 2.4 13.3 0.0 Property Boundary Monitoring Pt. GP-1 8 60 1018 120 > 100 > 100 40.3 0.1 30.2 0.0 Property Boundary Monitoring Pt. G P-19 60 1035 120 0.0 0.0 0.0 17.9 3.5 0.0 Property Boundary Monitoring Pt. NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification inc uding th possibility of a fine and imprisonment. Senior Geologist / S&ME, Inc. SIGNATU TITLE Revised - February 4, 2020 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: 2/22/2024 NC Landfill Rule (.0500 or. 1600): 0.0500 Sample Collector Name & Position: Edmund Henriques / Senior Geologist, S&ME, Inc. Gas Meter Type & Serial Number: GEM 5000 Plus / G507520 Field Calibration Date & Time: 2/16/2024 Gas Meter Calibration Date: 5/9/2023 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 1/1/2028 Gas Meter Pump Rate: 703 cm/min Ambient Air Temperature: 60 F Barometric Pressure (in. or mm Hg): 29.59 Weather Conditions: Sun Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) initial % LEL Stabilized /o LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES MW-6 60 1030 120 >100 >100 17.8 2.6 18.7 0 not a compliance point GV-33 60 1010 120 > 100 >100 49.5 0.1 34.7 0 Passive vent, not a compliance point GV-34 60 1013 120 >100 >100 49.9 0.1 35.0 0 Passive vent, not a compliance point GV-35 60 1002 120 >100 >100 57.5 0.2 36.8 0 Passive vent, not a compliance point GV-36 60 1006 120 >100 >100 59.1 0.2 37.1 0 Passive vent, not a compliance point Maintenance Shop 60 1236 120 0.0 0.0 0.0 20.9 0.1 0 on -site structure Transfer Station 60 1230 120 0.0 0.0 0.0 20.9 0.1 0 on -site structure Blake Residence 60 1330 120 0.0 0.0 0.0 21.1 0.1 0 off -site structure Scale House 60 930 120 0.0 0.0 0.0 20.0 0.1 0 on -site structure GP-20 60 1024 120 >100 >100 23.9 0.1 22.8 0 Monitoring point, west of cut-off trench GP-21 60 957 120 >100 >100 59.2 0.2 36.7 0 Monitoring point, east of cut-off trench NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >_1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification incll�udfi�ng the possibility of a fine and imprisonment. ,jimlj 111 Senior Geologist / S&ME, Inc. SIGNATURE Y TITLE Revised - March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: 2/22/2024 NC Landfill Rule (.0500 or.1600): 0.0500 Sample Collector Name & Position: Edmund Henriques / Senior Geologist, S&ME, Inc. Gas Meter Type & Serial Number: GEM 5000 Plus / G507520 Gas Meter Calibration Date: 5/9/2023 Field Calibration Date & Time: 2/16/2024 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 1/1/2028 Gas Meter Pump Rate: 703 cm/min Ambient Air Temperature: 60 F Barometric Pressure (in. or mm Hg): 29.59 Weather Conditions: Sun Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 � volume � % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES GV-30 60 1459 120 > 100 > 100 57.3 0.1 36.1 0 Passive vent, not a compliance point GV-31 60 1503 120 > 100 > 100 55.1 0.2 37.7 0 Passive vent, not a compliance point GV-32 60 1505 120 > 100 > 100 55.5 0.2 37.0 0 Passive vent, not a compliance point GV-37 60 1442 120 > 100 > 100 55.3 0.7 36.1 0 Passive vent, not a compliance point GV-38 60 1451 120 > 100 > 100 57.9 0.1 37.4 0 Passive vent, not a compliance point GV-39 60 1447 120 > 100 > 100 59.0 0.1 36.9 0 Passive vent, not a compliance point GV-40 60 1445 120 > 100 > 100 58.4 0.2 38.2 0 Passive vent, not a compliance point GV-41 60 1442 120 > 100 > 100 58.4 0.2 37.5 0 Passive vent, not a compliance point NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification i clud�'Ot possibility of a fine and imprisonment. Senior Geologist / S&ME, Inc. SIGNATURE TITLE Revised — March 6, 2017 r il I P"Pp"CERTI FICATIO OF CALIBRATION No. 66916 Date Of Calibration: 09-May-2023 Certificate Number: G507520_10/46182 Issued by: QED Environmental Systems Inc. Customer: ENVIRO EQUIPMENT INC 11180 DOWNS RD PINEVILLE, NC 28134 US Description: Landtec Gas Analyzer Model. GEM5000 Serial Number: G507520 Accredited Results: Methane (CH4) Certified Gas % Instrument Readin % Uncertainty% 5.0 4.9 0.42 15.0 14.9 0.66 50.0 50.2 1.03 Carbon Dioxide CO2 Certified Gas % Instrument Reading % Uncertainty 5.0 4.9 0.43 15.1 15.0 0.71 50.0 50.2 1.19 Oxygen 02 Certified Gas N Instrument Reading % Uncertainty 20.9 21.0 0.25 Gas cylinders are traceable and details can be provided if requested. CH4, CO2 readings recorded at: 32.0 °C/89.6 7 Barometric Pressure: 0987"Hg/29.14 "Hg 02 readings recorded at: 22.9 °C/73.3 °F Method of Test : The analyzer is calibrated in a temperature controlled chamber using a series of reference gases, in compliance with procedure ISP17. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. The uncertainty evaluation has been carried out in accordance with NIST requirements. The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NISTto the International System of Units (sl). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Calibration Instance: 116 IGC Instance: 116 Page 1 of 2 I LP015LNANIST--1.1 www.gedenv.com (800) 624-2026 info@gedenv.com Pr CERTIFICATION VJLA L OF C A L I B R A T I O N Ca11b�tron No. 66916 Date Of Calibration: 09-May-2023 Certificate Number: G507520_10/46182 Issued by: QED Environmental Systems Inc. Non Accredited results: Pressure Transducers inches of water column Transducer Certified (Low) Reading (Low) Certified (High) Reading;(High) Accuracy Static 0" 0"1 40" 39.717" 1 2.0" Oil I411 3.9" Differential Oil0.711 aq received Pas check readings: Methane CH4 Certified Gas % Instrument Reading % 5.0 5.0 15.0 15.4 50.0 50:1 Carbon Dioxide CO2 Certified Gas -- instrument Reading % 5.0 5.0 15.1 151 50.0 4918 Oxvgen 02 Certified Gas % Instrument Reading % 20.9 20:6 As received Gas readings recorded at: 32.0 `C/89.6 "F As received Barometric Pressure recorded at: 22.9 'C/73.3 T Date of Issue : 10 May 2023 Approved By Signatory Chris Fleenor Laboratory Inspection The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NIST to the International System of Units ($I). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Page 2 of 2I LPOMNANLST-1.1 Cahbr=n Ins== 116 IGC instance. 116 www.gedenv.com (800) 624-2026 info@gedenv.com -' -- i :-�� gar ,�♦ 17) tar MI AM 10 LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET 650715 ` Date 2 6 2 Inspector A Serial Number Time/Date � Battery Level ' Q0% Memory Cleared Pump Faults Gas Alarms: CH4 = ] 00.0% CO2 = 100.0% / OZ = 22.0% Zero Transducers GC Pump Flow Rate 703 li*It/1 Vacuum Tested To 80" H20_ / Calibration Check (Performed at Room Temperature) Calibration Gas Calibration Gas Lot Number Expiration Reading Accuracy* Concentration lap �/� . 0 g02.73`6$3� ± 2 /° /4D� o Pure NZ 60 ° g6263� 2 2Y t 2% High CH4 35 �� `I f2.�3�'�f 25 350 0 f 2% High CO2 f 2°r° Low CH4 t 2% Low CO2 a y / gofq 137oq v�� ° y, t 2/° Low 02 High OZ 20.9% N/A N/A t2% co 0 ,� 32=1- 10 5% 1 o°r° H2S fag�? �,�5 ± 10% *Accuracy depends upon calibration range; 151/o-FS range for CH4 & CO2, 0-5% volume for CL, 01/6-FS for H2S, and t 0% of reading for CO. INSPECTOR'S MAINTENANCE NOTES EEI GEM 2000 Plus Cal Form 01/12