Loading...
HomeMy WebLinkAboutNCS01661_INSP_20230929NORTH CARnLINAD_E Q�� o.n.mm.m m c.wmnm..t.i a.i� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer Compost SLAS COUNTY: Macon MSWLF PERMIT NO.: NCS-01661 Closed HHW White Incin T&P FIRM X MSWLF goods FILE TYPE: COMPLIANCE CDLF TireT&P Tire Industrial DEMO SDTF Collection Monofill Landfill Date of Site Inspection: 9/29/2023 FACILITY NAME AND ADDRESS: Erik's Grading & Septic 462 Gregory Rd. Franklin, NC 28734 FACILITY CONTACT INFORMATION: Name: Erik Tatum Address: Same as above Telephone: 828-526-6245 Email address: eriksgrading@gmail.com PARTICIPANTS: Stephanie Williams, DWM Solid Waste Section STATUS OF PERMIT: Pre -Operational PURPOSE OF SITE VISIT: Pre-operation/New pumper vehicle STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: N/A The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. Page 1 of 2 Oepartmenl o� Envimnmental0uali� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section ADDITIONAL COMMENTS 1) Pumper vehicle(s) inspected (trucks are numbered in the order they were inspected): TRUCK LICENSE PLATE # VIN # TANK CAPACITY (gal) 1 ZB-66499 1FDYR80U4HVA41574 2,500 2) 15A NCAC 13B .0835 (a)(1): The tank was affixed to the vehicle as required. 3) 15A NCAC 13B .0835 (a)(2): Valves appeared to be in working order and were closed. One valve was missing a cover at the time of inspection. Mr. Tatum added a cover and sent photos to Ms. Williams following the inspection. 4) 15A NCAC 13B .0835 (a)(3): Ports were closed and sealed at the time of inspection. 5) 15A NCAC 13B .0835(a): No leaks were noted during the inspection. 6) 15A NCAC 13B .0835 (b): All lettering was at least three (3) inches in height and listed the company name, town name, phone number, and permit number as required. The company name on the vehicle reads "Erik's Grading and Septic," whereas the application reads "Erik's Grading & Septic." A note has been made on the application in our records regarding the discrepancy. 7) The tank was full at the time of inspection. Mr. Tatum was able to arrange disposal with the WWTP and he worked with permitting to have the permit issued so he could dump the waste that was in the tank. 8) Truck was in compliance with the Septage Rules. ERIK'S GRADING AND SEPTIC (828) 526-6245 " _! AND SEPTIC / 151�10j 1fu�` Gt ERII(,S GI\�DI11�, NCS 07661 __ USDOT33]033] AND SEPTIC - - - NCS OT 0166i USA 337p3 Driver's side Passenger's side Please contact me if you have any questions or concerns regarding this inspection report. ,'q� U)4&� St p ah nie Williams, Environmental Speeialist II Division of Waste Management, NCDEQ Regional Representative Phone: (919) 605-5576 . Sent on: 12/12/2023 X Email Hand delivery US Mail Certified No. [ I Page 2 of 2