Loading...
HomeMy WebLinkAbout9226_ShotwellCDLF_LFGMonitoringUpdate_FID1827661_20240202 REPORT OF GROUNDWATER AND METHANE MONITORING WELL ABANDONMENT AND INSTALLATION SHOTWELL C&D LANDFILL WENDELL, NORTH CAROLINA PERMIT NO. 9226-CDLF-2020 Prepared For: Meridian Waste North Carolina, LLC 5925 Carnegie Blvd, Suite 370 Charlotte, North Carolina 28209 Prepared By: Bunnell-Lammons Engineering, Inc. 6004 Ponders Court Greenville, SC 29615 BLE Project Number J23-14374-10 February 1, 2024 BLE North Carolina Business Licenses C-284 & C-1538 February 1, 2024 Meridian Waste North Carolina, LLC 5925 Carnegie Blvd, Suite 370 Charlotte, North Carolina 28209 Attention: Mr. Murray Long Corporate Landfill Director Subject: Report of Groundwater and Methane Monitoring Well Abandonment and Installation Shotwell C&D Landfill Wendell, North Carolina Facility Permit No. 9226-CDLF-2020 BLE Project Number J23-14374-10 Dear Mr. Long: As authorized by acceptance of Bunnell-Lammons Engineering, Inc. (BLE) Proposal Number J23-14374-10 dated December 8, 2023, we are pleased to submit this report in collaboration with Hodges, Harbin, Newberry, & Tribble, Inc. (HHNT) to Meridian Waste North Carolina, LLC (Meridian). This report describes the work performed and presents the results obtained. The purpose of this work was to update the facility’s environmental monitoring network. The work included the abandonment of one (1) groundwater monitoring well and one (1) methane monitoring well, the installation of one (1) replacement groundwater monitoring well, one (1) replacement methane monitoring well, and three (3) new methane monitoring wells. Included herein is a brief description of the background project information, a description of the scope of services performed, summary, qualifications, and references. Sincerely, BUNNELL LAMMONS ENGINEERING INC. Zachery J. Downes, P.G. Andrew W. Alexander, P.G., RSM Project Geologist Consultant Hydrogeologist Registered, NC No. 2618 Registered, NC No. 1475 cc: Michael Stubbs, P.E. – HHNT Dave Sanders – HHNT William Putnal – HHNT Report of Groundwater and Methane Monitoring Well Abandonment and Installation February 1, 2024 Shotwell C&D Landfill – Wendell, North Carolina BLE Project No. J23-14374-10 i of i TABLE OF CONTENTS 1.0 PROJECT INFORMATION ........................................................................................................ 1 2.0 FIELD PROCEDURES AND ACTIVITIES ............................................................................... 1 2.1 General ............................................................................................................................................. 1 2.2 Groundwater Monitoring Well and Methane Monitoring Well Abandonment ............................... 2 2.3 Drilling Procedures and Subsurface Conditions Encountered ......................................................... 2 2.4 Groundwater Monitoring Well Installation and Construction ......................................................... 2 2.4.1 Groundwater Monitoring Well Development ......................................................................... 3 2.5 Methane Monitoring Well Installation and Construction ................................................................ 3 3.0 SUMMARY .................................................................................................................................... 4 4.0 QUALIFICATIONS OF REPORT .............................................................................................. 4 Tables Table 1 Groundwater and Methane Monitoring Well Abandonment Summary Table 2 Groundwater and Methane Monitoring Well Construction Information Figures Figure 1 Site Location Map Figure 2 Environmental Monitoring Network Map Appendices Appendix A As-Built Survey Data Appendix B North Carolina Form GW-30 Well Abandon Record Appendix C Boring Logs and Well Construction Diagrams Appendix D North Carolina Form GW-1 Well Construction Record Appendix E Soil Laboratory Testing Results Appendix F Groundwater Monitoring Well Development Log Report of Groundwater and Methane Monitoring Well Abandonment and Installation February 1, 2024 Shotwell C&D Landfill – Wendell, North Carolina BLE Project No. J23-14374-10 1 of 4 1.0 PROJECT INFORMATION The Shotwell C&D Landfill (herein referred to as “Site”) is located in Wake County, North Carolina, with a physical address of 4724 Smithfield Road, Wendell, North Carolina (Figure 1). Meridian Waste North Carolina, LLC (Meridian) owns and operates the Site (Permit No. 9226-CDLF-2020). The facility consists of five (5) constructed waste units (Phases 1-5) and one (1) waste unit currently under construction (Phase 6A). Meridian requested that background groundwater monitoring well MW-1A be abandoned and reinstalled to accommodate landfill soil stockpiling activities. BLE prepared a document titled Work Plan for Groundwater Monitoring Well Abandonment and Replacement, dated December 13, 2023 (FID 1822937) which was submitted to the North Carolina Division of Waste Management - Solid Waste Section (SWS) for their concurrence on the abandonment of background groundwater monitoring well MW-1A and the proposed location of the replacement well (MW-1AR). The SWS approved the work plan via email on December 18, 2023. Additionally, methane monitoring well LG-8R had measurable amounts of methane in exceedance of the Lower Explosive Limit (LEL) during the 4th Quarter 2023 landfill gas monitoring event. As a result of the exceedance, HHNT prepared a document titled Methane Exceedance Notice – Q4 2023 Landfill Gas Monitoring, dated December 6, 2023 (FID 1822935), notifying the SWS of the exceedance and proposing remedial actions. The remedial actions included:  Abandonment and relocation of LG-8R;  Installation of two additional methane monitoring wells (LG-13 & LG-14) near the property boundary on either side of LG-8R2 to delineate landfill gas in the area; and,  Installation of one new methane monitoring well (LG-12) in conjunction with the construction of Phase 6A. The SWS approved the proposed remedial actions via email on December 18, 2023. HHNT provided BLE with a map in PDF format of the methane monitoring well installation locations approved by the SWS. BLE was retained by Meridian to provide the abandonment and installation services. This report documents the abandonment and installation activities listed above in general accordance with the facility’s approved Water Quality Monitoring Plan (WQMP) and the November 2010 (updated August 2021) SWS guidance titled Landfill Gas Monitoring Guidance. 2.0 FIELD PROCEDURES AND ACTIVITIES 2.1 General Field activities were performed between January 4, 2024 and January 11, 2024. A North Carolina licensed driller from Bridger Drilling of Wilmington, NC, performed the groundwater monitoring well and methane monitoring well abandonment and installation activities which were documented by a geologist from BLE. A North Carolina registered surveyor from Advanced Civil Design of Cary, NC was retained by HHNT to survey the new well locations for horizontal and vertical control (Appendix A). We understand that the Report of Groundwater and Methane Monitoring Well Abandonment and Installation February 1, 2024 Shotwell C&D Landfill – Wendell, North Carolina BLE Project No. J23-14374-10 2 of 4 survey was performed on January 22, 2024. BLE received the surveyor’s certification report on February 1, 2024. 2.2 Groundwater Monitoring Well and Methane Monitoring Well Abandonment One (1) groundwater monitoring well (MW-1A) and one (1) methane monitoring well (LG-8R) were permanently abandoned in general accordance with the facility’s approved WQMP and the November 2010 (updated August 2021) SWS guidance titled Landfill Gas Monitoring Guidance. MW-1A and LG-8R were abandoned using the following procedures:  The total depth of each well was initially measured with a weighted tag line;  The total depth of each well’s PVC casing and screen was filled with bentonite-slurry from the bottom of the well to the top of casing via tremie pipe;  The concrete pad and steel protective cover were removed from each well;  The entire depth of each well was over-drilled to remove the well construction materials; and,  The resulting boreholes were filled with 5% bentonite cement grout from the bottom of the borehole to 10 feet below ground surface via tremie pipe. The remaining borehole was backfilled with 3/8-inch bentonite chips, hydrated in lifts, to ground surface. A summary of the completed abandonment activities is included in Table 1. Abandonment locations are shown on Figure 2. A North Carolina Form GW-30 Well Abandonment Record was prepared for each well, which are included as Appendix B. 2.3 Drilling Procedures and Subsurface Conditions Encountered The borings were performed using a CME-45C ATV-mounted drilling rig, employing hollow stem auger drilling techniques in the residual soil. The soil descriptions on the boring logs (Appendix C) were based on visual examination and on soil laboratory results. The descriptions conform to the Unified Soil Classification System (USCS). 2.4 Groundwater Monitoring Well Installation and Construction One (1) replacement groundwater monitoring well (MW-1AR) was installed at the site in general accordance with the facility’s approved WQMP. The groundwater monitoring well location is shown on Figure 2 and well construction diagrams are included in Appendix C. A North Carolina Form GW-1 Well Construction Record was completed for the groundwater monitoring well and is included in Appendix D. The groundwater monitoring well consists of 2-inch diameter polyvinyl chloride (PVC; Johnson Schedule 40, NSF-rated) casing with flush-threaded joints inserted in 8.25-inch nominal diameter borehole. The bottom 10-foot section of the well is a manufactured well screen with 0.010-inch-wide machined slots with a 0.25-foot-long sediment trap threaded onto the bottom of the screen section. The screen section of the monitoring well was set with a target water column of approximately 13 feet. Silica filter sand (DSI, #2) was placed around the outside of the pipe in the borehole annulus to a level above the top of the well screen. A hydrated bentonite seal (Baroid brand 3/8-inch diameter chips) was installed on top of the filter sand to seal the monitoring wells at the desired level. The remaining well Report of Groundwater and Methane Monitoring Well Abandonment and Installation February 1, 2024 Shotwell C&D Landfill – Wendell, North Carolina BLE Project No. J23-14374-10 3 of 4 annulus was grouted with a 5% bentonite-cement mixture from the top of the bentonite seal to within one- foot of the ground surface. The surface completion of the well consists of a PVC cap and a lockable 4-inch x 4-inch x 5-foot standup protective steel cover, with a 2-foot by 2-foot concrete pad at the base of the steel cover. An identification plate was fastened to the protective steel cover. The identification plate specifies the well identification number, drilling contractor, date installed, total depth, and construction details. A 4-inch x 4-inch wooden ID post painted blue was installed next to the well. The well was constructed with a vent hole in the PVC casing near the top of the well, a weep hole near the base of the outer protective steel cover, and a survey pin in the concrete pad. Laboratory analyses were performed on a soil sample collected from the depth of the well’s screened interval and the filter pack sand via ASTM D 422. The soil laboratory results are included in Appendix E. 2.4.1 Groundwater Monitoring Well Development The one (1) replacement groundwater monitoring well was purged and developed to reduce the groundwater turbidity utilizing conventional development techniques (surging and pumping). The total volume of groundwater purged was 27.5 gallons. Turbidity was measured during the well development using a Hach 2100Q Portable Turbidimeter. The initial turbidity exceeded 1,000 NTUs but was developed until further development did not substantially reduce the turbidity level. The final turbidity value achieved was 9.8 NTUs. A summary of the well development is attached in Appendix F. 2.5 Methane Monitoring Well Installation and Construction One (1) replacement methane monitoring well (LG-8R2) and three (3) new methane monitoring wells (LG-12, LG-13, and LG-14) were installed at the site in general accordance with the November 2010 (updated August 2021) SWS guidance titled Landfill Gas Monitoring Guidance. The methane monitoring well locations are shown on Figure 2 and well construction diagrams are included in Appendix C. A North Carolina Form GW-1 Well Construction Record was completed for each of the methane monitoring wells and are included in Appendix D. The methane monitoring wells consist of 2-inch diameter PVC (Johnson Schedule 40, NSF-rated) casing inserted into 8.25-inch nominal diameter boreholes. The screens were set to span the majority of the vadose zone, beginning at the first occurrence of bedrock or groundwater, whichever was shallower. The screened section of the casing consisted of manufactured PVC well screen with 0.010-inch-wide machined slots and a threaded endcap. Filter pack sand (DSI, #2) was placed from the bottom of the borehole to above the static groundwater level for boreholes that extended beyond the first occurrence of groundwater. The annulus of the screened interval was filled with washed quartz pea gravel from the top of sand to 5 feet bgs. The remaining annulus of the wells consists of an approximately 0.5-foot layer of filter sand placed on top of the pea gravel, an approximate 1-foot layer of hydrated 3/8-inch bentonite chips placed on top of the filter sand, and a 5% bentonite-cement mixture to the ground surface. The surface completion of the wells consists of a quick connect cap and a lockable 4-inch x 4-inch x 5-foot standup protective steel cover, with a 2-foot by 2-foot concrete pad at the base of the steel cover. An identification plate was fastened to the protective steel cover. The identification plate specifies the well identification number, drilling contractor, date installed, total depth, and construction details. A 4-inch x 4-inch wooden ID post painted red was installed next to each methane well. The wells were constructed with a weep hole near the base of the outer protective steel cover, and a survey pin in the concrete pad. Report of Groundwater and Methane Monitoring Well Abandonment and Installation February 1, 2024 Shotwell C&D Landfill – Wendell, North Carolina BLE Project No. J23-14374-10 4 of 4 3.0 SUMMARY The groundwater monitoring network has been updated by abandoning one (1) existing groundwater monitoring well (MW-1A) and installing and developing one (1) replacement groundwater monitoring well (MW-1AR). The landfill gas monitoring network has been updated and expanded by abandoning one (1) existing methane monitoring well (LG-8R) and installing one (1) replacement methane monitoring well (LG- 8R2) and three (3) new methane monitoring wells (LG-12, LG-13, and LG-14). The abandonment and installation activities were performed in general accordance with the facility’s approved WQMP and the November 2010 (updated August 2021) SWS guidance titled Landfill Gas Monitoring Guidance. 4.0 QUALIFICATIONS OF REPORT The activities and evaluative approaches used in this scope of work are consistent with those normally employed for services of this type. Our services have been performed based on our understanding of the site and the observations made during our work. This report has been prepared on behalf of and exclusively for the use of Meridian. This report and the findings contained herein shall not, in whole or in part, be used or relied upon by any other party (excluding the SWS) without BLE’s prior written consent. Tables Table 1 Groundwater and Methane Monitoring Well Abandonment Summary Shotwell C&D Landfill Wendell, North Carolina Permit No. 9226-CDLF-2020 BLE Project Number J23-14374-10 Abandonment Methods MW-1A 38.0 37.7 40.4 1/5/24 286.30 Approx. 6.5-gallons bentonite slurry inside PVC casing. Approx. 84-gallons 5% bentonite-grout in resulting borehole up to 10-feet bgs. 350lbs 3/8-inch bentonite chips to ground surface. LG-8R 32.0 31.1 33.4 1/5/24 286.40 Approx. 5.5-gallons bentonite slurry inside PVC casing. Approx. 64-gallons 5% bentonite-grout in resulting borehole up to 10-feet bgs. 300lbs 3/8-inch bentonite chips to ground surface. Notes: Abandonment ativities performed by Bridger Drilling on January 4-5, 2024 bgs = Below Ground Surface 1 Elevations are in FEET above mean seal level (MSL) 1. Measured the total depth of each well. 2. Placed bentonite-slurry inside the PVC casing from bottom of well to top of casing via tremie pipe. 3. Removed concrete pad and steel stickup. 4. Cut grouted PVC casing off approximately level with ground surface. 5. Over-drilled the entire depth of well with 8.25-inch hollow stem augers. 6. Filled resulting borehole with 5% bentonite-grout from bottom of borehole to 10-feet below ground surface via tremie pipe. 7. Backfilled remaining 10-feet to ground surface with 3/8-inch bentonite chips. Equipment Used (rig, auger size, etc.) Grout/Bentonite Amount Ground Surface Elevation1 CME-45C, 8.25-inch O.D. Hollow Stem Auger Well Reported Depth (bgs) Tagged Depth (bgs) Drilled-Out to: Date Abandoned Prepared by: ZJD Checked by: TCG Table 2 Groundwater and Methane Monitoring Well Construction Information Shotwell C&D Landfill Wendell, North Carolina Permit No. 9226-CDLF-2020 BLE Project Number J23-14374-10 Survey Information Ground Survey Disk TOC Northing Easting Latitude Longitude Screen Depth Below Screen Unit Well Elevation Elevation Elevation (ft)(ft)(dd)(dd)Ground Surface Elevation Screened MW-1AR 288.59 288.88 292.67 720,033.62 2,167,042.08 35.727096 -78.437187 39.4 -49.4 249.2 -239.2 Residuum LG-8R2 288.50 288.68 292.90 720,038.50 2,167,040.72 35.727109 -78.437192 5.5 -30.5 283.0 -258.0 Residuum LG-12 263.24 263.40 267.42 719,637.70 2,166,217.80 35.726021 -78.439972 8.5 -13.5 254.8 -249.8 Residuum LG-13 284.46 284.71 288.61 719,650.93 2,166,708.91 35.726050 -78.438317 9.2 -29.2 275.3 -255.3 Residuum LG-14 284.28 284.67 289.02 719,752.05 2,167,314.92 35.726318 -78.436273 5.7 -35.7 278.6 -248.6 Residuum Notes: 1. Elevations are in FEET above mean sea level (MSL) 2. Depths indicated are in FEET 3. TOC = top of casing (PVC) 4. Survey perfomed by Advanced Civil Design of Cary, North Carolina on January 22, 2024. 5. Latitude and Longitude converted from State Plane. Groundwater Wells Methane Probes 14374-10 Shotwell LF Well Install Table.xlsx Table 1 Prepared By: RLB Checked By: ZJD Figures WAKE C O. JOH N S T O N C O. PROPERTY BOUNDARY EXISTING PERMITTED WASTE BOUNDARY UNCONSTRUCTED PERMITTED WASTE AREA 1 300310320240 250260270280 250260270280290300310320250240 270 280290300310320330220230240250260270280 230240250260270 260 27 0 280 29 0280 270 280290 300SMITHFIELD ROADSCALE HOUSEMAINTENANCEGARAGESCALEPERMITTED LANDFILLFOOTPRINTPHASE 1-5WASTE LIMITPROPERTY BOUNDARY(TYP.)APPROXIMATE LAND CLEARINGAND INERT DEBRIS (LCID) AREAEXISTINGSEDIMENT PONDEXISTINGSEDIMENTPONDEXISTINGSEDIMENT PONDEXISTINGSEDIMENTPONDEXISTINGPHASE 1-5FILL AREA290 290270250260 290210200 UNDERCONSTRUCTIONPHASE 6APROPOSED EDGE OFPHASE 6A (TYP.) APPENDIX A As-Built Survey Data SM I T H F I E L D RO A D ( S R 2 2 3 3 ) SEAL L - 5273PROFESSIO N A LNORT H C AROLIN A L A ND SUR VJ A MES D W.H IT AE YORCRENC GRID NAD 83 (2011 ADJUSTMENT)ADVANCED C I V I L D E S I G N E N G I N E E R S S U R V YE O R S 51 Kilmayne Drive Suite 102 Cary, North Carolina 27511 ph 919.481.6290 fax 919.336.5127 Firm License # C-2798 As-Built Survey for Shotwell Landfill Monitoring Points O:\22-0007-1193NC\DWG\Production Drawings\SURVEY\As-Built\0007-1193 As-built.dwg, Layout1 (3), 1/29/2024 9:01:38 AM, bwaranowski01/29/2024 APPENDIX B North Carolina Form GW-30 Well Abandon Record WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation□Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer□Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or wellabandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Mike Radford 4267-A NA Bridger Drilling NA NA NA Cement-bentonite grout - 90.5 gallons bentonite chips - 350 lbs 1/5/24 See Report. Shotwell C&D Landfill 9226-CDLF-2020 4724 Smithfield Rd, Wendell, 27591 1/23/24 Wake 1761682890 35.7258342 78.4373614 MW-1A 37.7 8.25 NA NA NA NA WELL ABANDONMENT RECORD Form GW-30 North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 1.Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) if known 3.Well use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply)□Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation□Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer□Geothermal (Heating/Cooling Return) □Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth: (ft.) 6c. Borehole diameter: (in.) 6d. Water level below ground surface: (ft.) 6e. Outer casing length (if known): (ft.) 6f. Inner casing/tubing length (if known): (ft.) 6g. Screen length (if known): (ft.) WELL ABANDONMENT DETAILS 7a. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same well construction/depth, only 1 GW-30 is needed. Indicate TOTAL NUMBER of wells abandoned: 7b. Approximate volume of water remaining in well(s): (gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): □Neat Cement Grout □Bentonite Chips or Pellets □Sand Cement Grout □Dry Clay □Concrete Grout □Drill Cuttings □Specialty Grout □Gravel □Bentonite Slurry □Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8.Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9.Site diagram or additional well details: You may use the back of this page to provide additional well site details or wellabandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells: Submit this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells: In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells: In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where abandoned. For Internal Use ONLY: Mike Radford 4267-A NA Bridger Drilling NA NA NA Cement-bentonite grout - 69.5 gallons Bentonite chips - 300 lbs 1/5/24 See Report. Shotwell C&D Landfill 9226-CDLF-2020 4724 Smithfield Rd, Wendell, 27591 1/23/24 Wake 1761682890 35.7258527 78.4373731 LG-8R 31.1 8.25 NA NA NA NA APPENDIX C Boring Logs and Well Construction Diagrams Dark brown to red, some organics, silty SAND Dark brown to red, clayey, silty SAND Reddish brown, silty SAND Light brown to tan, silty, medium SAND Cement Grout, 0 to 34.2 feet SURFACE COMPLETION4" X 4" stand-up locking steelprotective cover with a 2'x2'concrete pad at the base with survey pin. 1/8-inch weep hole and vent hole installed in steel coverand pvc stick up, respectively.Ground surface elev. = 288.59' Top of PVC casing elev. = 292.67' Stick up = 4.08' Northing = 720,033.62' Easting = 2,167,042.08' Bentonite seal, 34.2 to 37.6 feet Filter pack, sand 37.6 to 50.4 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 285 280 275 270 265 260 255 250 CAVING> GROUNDWATER MONITORING WELL NO. MW-1ARSheet 1 of 2 1-10-24 DEPTH TO - WATER> INITIAL: CLIENT: 46.1 PROJECT NO.: END:Meridian Waste North Carolina, LLC Wendell, North Carolina Bridger Drilling, Mike Radford ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME-45C with 8.25 inch O.D. Hollow Stem Auger J23-14374-10 AFTER 24 HOURS:36.2 GROUNDWATER MONITORING WELL NO. MW-1AR START: 1-10-24 288.59ELEVATION: T. GerringerLOGGED BY: Shotwell Probe and Well Install GEOT_WELL NO SAMPLE 14374-10.GPJ 1/25/24SOILTYPE MONITOR WELL INSTALLATIONDETAILS Light brown to tan, silty, medium SAND Brown to tan, silty, fine to medium SAND Boring terminated at 50.4 feet below ground surface. Groundwaterencountered at 46.1 feet below ground surface at time of drilling and at 36.2feet 24 hours after drilling. 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 39.4to 49.4 feet Pipe capTotal well depth, 49.6 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 245 240 235 230 225 220 215 210 CAVING> GROUNDWATER MONITORING WELL NO. MW-1ARSheet 2 of 2 1-10-24 DEPTH TO - WATER> INITIAL: CLIENT: 46.1 PROJECT NO.: END:Meridian Waste North Carolina, LLC Wendell, North Carolina Bridger Drilling, Mike Radford ELEVATION/DEPTH (FT) 45 50 55 60 65 70 75 PROJECT: CME-45C with 8.25 inch O.D. Hollow Stem Auger J23-14374-10 AFTER 24 HOURS:36.2 GROUNDWATER MONITORING WELL NO. MW-1AR START: 1-10-24 288.59ELEVATION: T. GerringerLOGGED BY: Shotwell Probe and Well Install GEOT_WELL NO SAMPLE 14374-10.GPJ 1/25/24SOILTYPE MONITOR WELL INSTALLATIONDETAILS Dark brown, moist, some organics, silty SAND Brown to red, moist, clayey, silty SAND Reddish brown, dry, silty SAND Light brown to tan, dry, silty SAND Light brown to tan, dry, micaceous, silty, fine to medium SAND Dark tan, dry, micaceous, silty, medium SAND Dark tan, wet, micaceous, silty, medium to coarse SAND Cement Grout, 0 to 3.4 feet Bentonite seal, 3.4 to 4.3 feet Filter pack, sand 4.3 to 5.0 feet SURFACE COMPLETION4" X 4" stand-up locking steelprotective cover with a 2'x2'concrete pad at the base with survey pin. 1/8-inch weep hole installed in the steel cover. Ground surface elev. = 288.50' Top of PVC casing elev. = 292.90' Stick up = 4.40' Northing = 720,038.50' Easting = 2,167,040.72' Filter pack, pea gravel 5.0 to 30.8feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 5.5to 30.5 feet Pipe capTotal well depth, 30.8 feet Filter pack, sand 30.8 to 45.4 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 285 280 275 270 265 260 255 250 CAVING> METHANE PROBE NO. LG-8R2Sheet 1 of 2 1-10-24 DEPTH TO - WATER> INITIAL: CLIENT: 33.7 PROJECT NO.: END:Meridian Waste North Carolina, LLC Wendell, North Carolina Bridger Drilling, Mike Radford ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME-45C with 8.25 inch O.D. Hollow Stem Auger J23-14374-10 AFTER 24 HOURS:NM METHANE PROBE NO. LG-8R2 START: 1-9-24 288.50ELEVATION: T. GerringerLOGGED BY: Shotwell Probe and Well Install GEOT_WELL NO SAMPLE 14374-10.GPJ 1/25/24MONITOR WELL INSTALLATIONDETAILSSOILTYPE Boring terminated at 45.4 feet below ground surface. Groundwaterencountered at 33.7 feet below ground surface at time of drilling. DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 245 240 235 230 225 220 215 210 CAVING> METHANE PROBE NO. LG-8R2Sheet 2 of 2 1-10-24 DEPTH TO - WATER> INITIAL: CLIENT: 33.7 PROJECT NO.: END:Meridian Waste North Carolina, LLC Wendell, North Carolina Bridger Drilling, Mike Radford ELEVATION/DEPTH (FT) 45 50 55 60 65 70 75 PROJECT: CME-45C with 8.25 inch O.D. Hollow Stem Auger J23-14374-10 AFTER 24 HOURS:NM METHANE PROBE NO. LG-8R2 START: 1-9-24 288.50ELEVATION: T. GerringerLOGGED BY: Shotwell Probe and Well Install GEOT_WELL NO SAMPLE 14374-10.GPJ 1/25/24MONITOR WELL INSTALLATIONDETAILSSOILTYPE Reddish brown, dry, silty, medium SAND Light brown, dry, silty, fine to medium SAND Brown, dry, silty, fine to medium SAND Brown to tan, dry, silty, fine to medium SAND Tan, wet, silty, medium SAND Boring terminated at 25.0 feet below ground surface. Groundwaterencountered at 15.3 feet below ground surface at time of drilling. Cement Grout, 0 to 3.4 feet Bentonite seal, 3.4 to 4.3 feet Filter pack, sand 4.3 to 5.0 feet Filter pack, pea gravel 5.0 to 13.7feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 8.5to 13.5 feet Pipe capTotal well depth, 13.7 feet Filter pack, sand 13.7 to 25.0 feet SURFACE COMPLETION4" X 4" stand-up locking steelprotective cover with a 2'x2'concrete pad at the base with survey pin. 1/8-inch weep hole installed in the steel cover. Ground surface elev. = 263.24' Top of PVC casing elev. = 267.42' Stick up = 4.18' Northing = 719,637.70' Easting = 2,166,217.80' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 260 255 250 245 240 235 230 225 CAVING> METHANE PROBE NO. LG-12Sheet 1 of 1 1-11-24 DEPTH TO - WATER> INITIAL: CLIENT: 15.3 PROJECT NO.: END:Meridian Waste North Carolina, LLC Wendell, North Carolina Bridger Drilling, Mike Radford ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME-45C with 8.25 inch O.D. Hollow Stem Auger J23-14374-10 AFTER 24 HOURS: METHANE PROBE NO. LG-12 START: 1-11-24 263.24ELEVATION: T. GerringerLOGGED BY: Shotwell Probe and Well Install GEOT_WELL NO SAMPLE 14374-10.GPJ 1/25/24MONITOR WELL INSTALLATIONDETAILSSOILTYPE Red to brown, dry, micaceous, sandy, clayey SILT Red to brown, dry, micaceous, sandy SILT Light brown, dry, micaceous, silty SAND Light brown to gray, dry, micaceous, silty SAND Light brown to gray, wet, micaceous, silty SAND Boring terminated at 38.0 feet below ground surface. Groundwaterencountered at 32.1 feet below ground surface at time of drilling. Cement Grout, 0 to 3.7 feet Bentonite seal, 3.7 to 4.4 feet Filter pack, sand 4.4 to 5.0 feet Filter pack, pea gravel 5.0 to 29.4feet SURFACE COMPLETION 4" X 4" stand-up locking steel protective cover with a 2'x2'concrete pad at the base withsurvey pin. 1/8-inch weep holeinstalled in the steel cover. Ground surface elev. = 284.46' Top of PVC casing elev. = 288.61' Stick up = 4.15' Northing = 719,650.93' Easting = 2,166,708.91' 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 9.2to 29.2 feet Pipe capTotal well depth, 29.4 feet Filter pack, sand 29.4 to 38.0 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 280 275 270 265 260 255 250 245 CAVING> METHANE PROBE NO. LG-13Sheet 1 of 1 1-9-24 DEPTH TO - WATER> INITIAL: CLIENT: 32.1 PROJECT NO.: END:Meridian Waste North Carolina, LLC Wendell, North Carolina Bridger Drilling, Mike Radford ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME-45C with 8.25 inch O.D. Hollow Stem Auger J23-14374-10 AFTER 24 HOURS: METHANE PROBE NO. LG-13 START: 1-8-24 284.46ELEVATION: T. GerringerLOGGED BY: Shotwell Probe and Well Install GEOT_WELL NO SAMPLE 14374-10.GPJ 1/25/24MONITOR WELL INSTALLATIONDETAILSSOILTYPE Gray to brown, moist, micaceous, sandy SILT Gray to reddish brown, moist, micaceous, sandy SILT Brown to red, dry, micaceous, clayey, sandy SILT Light brown, dry, micaceous, sandy SILT Light brown to white, dry, micaceous, silty SAND Light brown to gray, dry, micaceous, silty SAND Light brown to gray, moist, micaceous, silty SAND Cement Grout, 0 to 3.3 feet Bentonite seal, 3.3 to 4.4 feet Filter pack, sand 4.4 to 5.0 feet SURFACE COMPLETION4" X 4" stand-up locking steelprotective cover with a 2'x2'concrete pad at the base withsurvey pin. 1/8-inch weep hole installed in the steel cover. Ground surface elev. = 284.28' Top of PVC casing elev. = 289.02' Stick up = 4.74' Northing = 719,752.05' Easting = 2,167,314.92' Filter pack, pea gravel 5.0 to 35.9feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 5.7to 35.7 feet Pipe capTotal well depth, 35.9 feet Filter pack, sand 35.9 to 45.0 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 280 275 270 265 260 255 250 245 CAVING> METHANE PROBE NO. LG-14Sheet 1 of 2 1-8-24 DEPTH TO - WATER> INITIAL: CLIENT: 36.4 PROJECT NO.: END:Meridian Waste North Carolina, LLC Wendell, North Carolina Bridger Drilling, Mike Radford ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME-45C with 8.25 inch O.D. Hollow Stem Auger J23-14374-10 AFTER 24 HOURS: METHANE PROBE NO. LG-14 START: 1-8-24 284.28ELEVATION: T. GerringerLOGGED BY: Shotwell Probe and Well Install GEOT_WELL NO SAMPLE 14374-10.GPJ 1/25/24MONITOR WELL INSTALLATIONDETAILSSOILTYPE Light brown to gray, wet, micaceous, silty SAND Boring terminated at 45.0 feet below ground surface. Groundwaterencountered at 36.4 feet below ground surface at time of drilling. DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 240 235 230 225 220 215 210 205 CAVING> METHANE PROBE NO. LG-14Sheet 2 of 2 1-8-24 DEPTH TO - WATER> INITIAL: CLIENT: 36.4 PROJECT NO.: END:Meridian Waste North Carolina, LLC Wendell, North Carolina Bridger Drilling, Mike Radford ELEVATION/DEPTH (FT) 45 50 55 60 65 70 75 PROJECT: CME-45C with 8.25 inch O.D. Hollow Stem Auger J23-14374-10 AFTER 24 HOURS: METHANE PROBE NO. LG-14 START: 1-8-24 284.28ELEVATION: T. GerringerLOGGED BY: Shotwell Probe and Well Install GEOT_WELL NO SAMPLE 14374-10.GPJ 1/25/24MONITOR WELL INSTALLATIONDETAILSSOILTYPE APPENDIX D North Carolina Form GW-1 Well Construction Record WELL CONSTRUCTION RECORD (GW-1) For Internal Use Only: Form GW-1 North Carolina Department of Environmental Quality - Division of Water Resources Revised 6-6-2018 1.Well Contractor Information: Well Contractor Name NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) 3.Well Use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply) □Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation □Wells > 100,000 GPDNon-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under #21 Remarks) 4. Date Well(s) Completed: Well ID# 5a. Well Location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W 6.Is(are) the well(s): □Permanent or □Temporary 7.Is this a repair to an existing well: □Yes or □No If this is a repair, fill out known well construction information and explain the nature of the repair under #21 remarks section or on the back of this form. 8. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same construction, only 1 GW-1 is needed. Indicate TOTAL NUMBER of wellsdrilled: 9. Total well depth below land surface: (ft.) For multiple wells list all depths if different (example- 3@200’ and 2@100′) 10.Static water level below top of casing: (ft.) If water level is above casing, use “+” 11. Borehole diameter: (in.) 12. Well construction method: (i.e. auger, rotary, cable, direct push, etc.) FOR WATER SUPPLY WELLS ONLY: 13a. Yield (gpm) Method of test: 13b. Disinfection type: Amount: 14. WATER ZONES FROM TO DESCRIPTION ft. ft. ft. ft. 15. OUTER CASING (for multi-cased wells) OR LINER (if applicable)FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. 16. INNER CASING OR TUBING (geothermal closed-loop)FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. ft. ft. in. 17. SCREENFROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL ft. ft. in. ft. ft. in. 18. GROUT FROM TO MATERIAL EMPLACEMENT METHOD & AMOUNT ft. ft. ft. ft. ft. ft. 19. SAND/GRAVEL PACK (if applicable) FROM TO MATERIAL EMPLACEMENT METHOD ft. ft. ft. ft. 20. DRILLING LOG (attach additional sheets if necessary) FROM TO DESCRIPTION (color, hardness, soil/rock type, grain size, etc.) ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. 21. REMARKS 22.Certification: Signature of Certified Well Contractor Date By signing this form, I hereby certify that the well(s) was (were) constructed in accordance with 15A NCAC 02C .0100 or 15A NCAC 02C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 23.Site diagram or additional well details:You may use the back of this page to provide additional wellconstructioninfo(add'SeeOver'inRemarksBox).Youmayalsoattachadditionalpagesifnecessary. 24.SUBMITTAL INSTRUCTIONS Submit this GW-1 within 30 days of well completion per the following: 24a. For All Wells: Original form to Division of Water Resources (DWR), Information Processing Unit, 1617 MSC, Raleigh, NC 27699-1617 24b. For Injection Wells: Copy to DWR, Underground Injection Control (IUC) Program, 1636 MSC, Raleigh, NC 27699-1636 24c. For Water Supply and Open-Loop Geothermal Return Wells: Copy to the county environmental health department of the county where installed 24d. For Water Wells producing over 100,000 GPD: Copy to DWR, CCPCUA Permit Program, 1611 MSC, Raleigh, NC 27699-1611 Mike Radford 4267-A Overburden Bridger Drilling 0.0 39.4 Sch 40 39.4 49.4 0.010 0.0 Grout 34.2 Bentonite 37.6 DSI #2 See Boring Log for MW-1AR1/10/24 MW-1AR Shotwell C&D Landfill 9226-CDLF-2020 4724 Smithfield Rd, Wendell, 27591 Wake 1761682890 35.7270960 78.4371872 1/23/24 49.6 39.8 8.25 Hollow Stem Auger 49.636.1 PVC Sch 40 PVC 2 2 34.2 37.6 50.4 Pour Tremie Pour WELL CONSTRUCTION RECORD (GW-1) For Internal Use Only: Form GW-1 North Carolina Department of Environmental Quality - Division of Water Resources Revised 6-6-2018 1.Well Contractor Information: Well Contractor Name NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) 3.Well Use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply) □Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation □Wells > 100,000 GPDNon-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under #21 Remarks) 4. Date Well(s) Completed: Well ID# 5a. Well Location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W 6.Is(are) the well(s): □Permanent or □Temporary 7.Is this a repair to an existing well: □Yes or □No If this is a repair, fill out known well construction information and explain the nature of the repair under #21 remarks section or on the back of this form. 8. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same construction, only 1 GW-1 is needed. Indicate TOTAL NUMBER of wellsdrilled: 9. Total well depth below land surface: (ft.) For multiple wells list all depths if different (example- 3@200’ and 2@100′) 10.Static water level below top of casing: (ft.) If water level is above casing, use “+” 11. Borehole diameter: (in.) 12. Well construction method: (i.e. auger, rotary, cable, direct push, etc.) FOR WATER SUPPLY WELLS ONLY: 13a. Yield (gpm) Method of test: 13b. Disinfection type: Amount: 14. WATER ZONES FROM TO DESCRIPTION ft. ft. ft. ft. 15. OUTER CASING (for multi-cased wells) OR LINER (if applicable)FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. 16. INNER CASING OR TUBING (geothermal closed-loop)FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. ft. ft. in. 17. SCREENFROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL ft. ft. in. ft. ft. in. 18. GROUT FROM TO MATERIAL EMPLACEMENT METHOD & AMOUNT ft. ft. ft. ft. ft. ft. 19. SAND/GRAVEL PACK (if applicable) FROM TO MATERIAL EMPLACEMENT METHOD ft. ft. ft. ft. 20. DRILLING LOG (attach additional sheets if necessary) FROM TO DESCRIPTION (color, hardness, soil/rock type, grain size, etc.) ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. 21. REMARKS 22.Certification: Signature of Certified Well Contractor Date By signing this form, I hereby certify that the well(s) was (were) constructed in accordance with 15A NCAC 02C .0100 or 15A NCAC 02C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 23.Site diagram or additional well details:You may use the back of this page to provide additional wellconstructioninfo(add'SeeOver'inRemarksBox).Youmayalsoattachadditionalpagesifnecessary. 24.SUBMITTAL INSTRUCTIONS Submit this GW-1 within 30 days of well completion per the following: 24a. For All Wells: Original form to Division of Water Resources (DWR), Information Processing Unit, 1617 MSC, Raleigh, NC 27699-1617 24b. For Injection Wells: Copy to DWR, Underground Injection Control (IUC) Program, 1636 MSC, Raleigh, NC 27699-1636 24c. For Water Supply and Open-Loop Geothermal Return Wells: Copy to the county environmental health department of the county where installed 24d. For Water Wells producing over 100,000 GPD: Copy to DWR, CCPCUA Permit Program, 1611 MSC, Raleigh, NC 27699-1611 Mike Radford 4267-A Overburden Bridger Drilling 0.0 5.5 Sch 40 5.5 30.5 0.010 0.0 Grout 3.4 Bentonite 4.3 DSI #2 5.0 Pea Gravel See Boring Log for LG-8R21/9/24 LG-8R2 Shotwell C&D Landfill 9226-CDLF-2020 4724 Smithfield Rd, Wendell, 27591 Wake 1761682890 Landfill Gas Monitoring Well 35.7271094 78.4371917 1/23/24 30.8 NA / Gas Well 8.25 Hollow Stem Auger 45.433.7 PVC Sch 40 PVC 2 2 3.4 4.3 5.0 45.4 Pour Pour Pour Pour WELL CONSTRUCTION RECORD (GW-1) For Internal Use Only: Form GW-1 North Carolina Department of Environmental Quality - Division of Water Resources Revised 6-6-2018 1.Well Contractor Information: Well Contractor Name NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) 3.Well Use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply) □Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation □Wells > 100,000 GPDNon-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under #21 Remarks) 4. Date Well(s) Completed: Well ID# 5a. Well Location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W 6.Is(are) the well(s): □Permanent or □Temporary 7.Is this a repair to an existing well: □Yes or □No If this is a repair, fill out known well construction information and explain the nature of the repair under #21 remarks section or on the back of this form. 8. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same construction, only 1 GW-1 is needed. Indicate TOTAL NUMBER of wellsdrilled: 9. Total well depth below land surface: (ft.) For multiple wells list all depths if different (example- 3@200’ and 2@100′) 10.Static water level below top of casing: (ft.) If water level is above casing, use “+” 11. Borehole diameter: (in.) 12. Well construction method: (i.e. auger, rotary, cable, direct push, etc.) FOR WATER SUPPLY WELLS ONLY: 13a. Yield (gpm) Method of test: 13b. Disinfection type: Amount: 14. WATER ZONES FROM TO DESCRIPTION ft. ft. ft. ft. 15. OUTER CASING (for multi-cased wells) OR LINER (if applicable)FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. 16. INNER CASING OR TUBING (geothermal closed-loop)FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. ft. ft. in. 17. SCREENFROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL ft. ft. in. ft. ft. in. 18. GROUT FROM TO MATERIAL EMPLACEMENT METHOD & AMOUNT ft. ft. ft. ft. ft. ft. 19. SAND/GRAVEL PACK (if applicable) FROM TO MATERIAL EMPLACEMENT METHOD ft. ft. ft. ft. 20. DRILLING LOG (attach additional sheets if necessary) FROM TO DESCRIPTION (color, hardness, soil/rock type, grain size, etc.) ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. 21. REMARKS 22.Certification: Signature of Certified Well Contractor Date By signing this form, I hereby certify that the well(s) was (were) constructed in accordance with 15A NCAC 02C .0100 or 15A NCAC 02C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 23.Site diagram or additional well details:You may use the back of this page to provide additional wellconstructioninfo(add'SeeOver'inRemarksBox).Youmayalsoattachadditionalpagesifnecessary. 24.SUBMITTAL INSTRUCTIONS Submit this GW-1 within 30 days of well completion per the following: 24a. For All Wells: Original form to Division of Water Resources (DWR), Information Processing Unit, 1617 MSC, Raleigh, NC 27699-1617 24b. For Injection Wells: Copy to DWR, Underground Injection Control (IUC) Program, 1636 MSC, Raleigh, NC 27699-1636 24c. For Water Supply and Open-Loop Geothermal Return Wells: Copy to the county environmental health department of the county where installed 24d. For Water Wells producing over 100,000 GPD: Copy to DWR, CCPCUA Permit Program, 1611 MSC, Raleigh, NC 27699-1611 Mike Radford 4267-A Overburden Bridger Drilling 0.0 8.5 Sch 40 8.5 13.5 0.010 0.0 Grout 3.4 Bentonite 4.3 DSI #2 5.0 Pea Gravel See Boring Log for LG-12.1/11/24 LG-12 Shotwell C&D Landfill 9226-CDLF-2020 4724 Smithfield Rd, Wendell, 27591 Wake 1761682890 Landfill Gas Monitoring Well 35.7260211 78.4399719 1/23/24 13.7 NA / Gas Well 8.25 Hollow Stem Auger 25.015.3 PVC Sch 40 PVC 2 2 3.4 4.3 5.0 25.0 Pour Pour Pour Pour WELL CONSTRUCTION RECORD (GW-1) For Internal Use Only: Form GW-1 North Carolina Department of Environmental Quality - Division of Water Resources Revised 6-6-2018 1.Well Contractor Information: Well Contractor Name NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) 3.Well Use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply) □Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation □Wells > 100,000 GPDNon-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under #21 Remarks) 4. Date Well(s) Completed: Well ID# 5a. Well Location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W 6.Is(are) the well(s): □Permanent or □Temporary 7.Is this a repair to an existing well: □Yes or □No If this is a repair, fill out known well construction information and explain the nature of the repair under #21 remarks section or on the back of this form. 8. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same construction, only 1 GW-1 is needed. Indicate TOTAL NUMBER of wellsdrilled: 9. Total well depth below land surface: (ft.) For multiple wells list all depths if different (example- 3@200’ and 2@100′) 10.Static water level below top of casing: (ft.) If water level is above casing, use “+” 11. Borehole diameter: (in.) 12. Well construction method: (i.e. auger, rotary, cable, direct push, etc.) FOR WATER SUPPLY WELLS ONLY: 13a. Yield (gpm) Method of test: 13b. Disinfection type: Amount: 14. WATER ZONES FROM TO DESCRIPTION ft. ft. ft. ft. 15. OUTER CASING (for multi-cased wells) OR LINER (if applicable)FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. 16. INNER CASING OR TUBING (geothermal closed-loop)FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. ft. ft. in. 17. SCREENFROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL ft. ft. in. ft. ft. in. 18. GROUT FROM TO MATERIAL EMPLACEMENT METHOD & AMOUNT ft. ft. ft. ft. ft. ft. 19. SAND/GRAVEL PACK (if applicable) FROM TO MATERIAL EMPLACEMENT METHOD ft. ft. ft. ft. 20. DRILLING LOG (attach additional sheets if necessary) FROM TO DESCRIPTION (color, hardness, soil/rock type, grain size, etc.) ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. 21. REMARKS 22.Certification: Signature of Certified Well Contractor Date By signing this form, I hereby certify that the well(s) was (were) constructed in accordance with 15A NCAC 02C .0100 or 15A NCAC 02C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 23.Site diagram or additional well details:You may use the back of this page to provide additional wellconstructioninfo(add'SeeOver'inRemarksBox).Youmayalsoattachadditionalpagesifnecessary. 24.SUBMITTAL INSTRUCTIONS Submit this GW-1 within 30 days of well completion per the following: 24a. For All Wells: Original form to Division of Water Resources (DWR), Information Processing Unit, 1617 MSC, Raleigh, NC 27699-1617 24b. For Injection Wells: Copy to DWR, Underground Injection Control (IUC) Program, 1636 MSC, Raleigh, NC 27699-1636 24c. For Water Supply and Open-Loop Geothermal Return Wells: Copy to the county environmental health department of the county where installed 24d. For Water Wells producing over 100,000 GPD: Copy to DWR, CCPCUA Permit Program, 1611 MSC, Raleigh, NC 27699-1611 Mike Radford 4267-A Overburden Bridger Drilling 0.0 9.2 Sch 40 9.2 29.2 0.010 0.0 Grout 3.7 Bentonite 4.4 DSI #2 5.0 Pea Gravel See Boring Log for LG-13.1/9/24 LG-13 Shotwell C&D Landfill 9226-CDLF-2020 4724 Smithfield Rd, Wendell, 27591 Wake 1761682890 Landfill Gas Monitoring Well 35.7260498 78.4383170 1/23/24 29.4 NA / Gas Well 8.25 Hollow Stem Auger 38.032.1 PVC Sch 40 PVC 2 2 3.7 4.4 5.0 38.0 Pour Pour Pour Pour WELL CONSTRUCTION RECORD (GW-1) For Internal Use Only: Form GW-1 North Carolina Department of Environmental Quality - Division of Water Resources Revised 6-6-2018 1.Well Contractor Information: Well Contractor Name NC Well Contractor Certification Number Company Name 2.Well Construction Permit #: List all applicable well construction permits (i.e. UIC, County, State, Variance, etc.) 3.Well Use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply) □Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation □Wells > 100,000 GPDNon-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop)□Tracer □Geothermal (Heating/Cooling Return) □Other (explain under #21 Remarks) 4. Date Well(s) Completed: Well ID# 5a. Well Location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W 6.Is(are) the well(s): □Permanent or □Temporary 7.Is this a repair to an existing well: □Yes or □No If this is a repair, fill out known well construction information and explain the nature of the repair under #21 remarks section or on the back of this form. 8. For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same construction, only 1 GW-1 is needed. Indicate TOTAL NUMBER of wellsdrilled: 9. Total well depth below land surface: (ft.) For multiple wells list all depths if different (example- 3@200’ and 2@100′) 10.Static water level below top of casing: (ft.) If water level is above casing, use “+” 11. Borehole diameter: (in.) 12. Well construction method: (i.e. auger, rotary, cable, direct push, etc.) FOR WATER SUPPLY WELLS ONLY: 13a. Yield (gpm) Method of test: 13b. Disinfection type: Amount: 14. WATER ZONES FROM TO DESCRIPTION ft. ft. ft. ft. 15. OUTER CASING (for multi-cased wells) OR LINER (if applicable)FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. 16. INNER CASING OR TUBING (geothermal closed-loop)FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. ft. ft. in. 17. SCREENFROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL ft. ft. in. ft. ft. in. 18. GROUT FROM TO MATERIAL EMPLACEMENT METHOD & AMOUNT ft. ft. ft. ft. ft. ft. 19. SAND/GRAVEL PACK (if applicable) FROM TO MATERIAL EMPLACEMENT METHOD ft. ft. ft. ft. 20. DRILLING LOG (attach additional sheets if necessary) FROM TO DESCRIPTION (color, hardness, soil/rock type, grain size, etc.) ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. 21. REMARKS 22.Certification: Signature of Certified Well Contractor Date By signing this form, I hereby certify that the well(s) was (were) constructed in accordance with 15A NCAC 02C .0100 or 15A NCAC 02C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 23.Site diagram or additional well details:You may use the back of this page to provide additional wellconstructioninfo(add'SeeOver'inRemarksBox).Youmayalsoattachadditionalpagesifnecessary. 24.SUBMITTAL INSTRUCTIONS Submit this GW-1 within 30 days of well completion per the following: 24a. For All Wells: Original form to Division of Water Resources (DWR), Information Processing Unit, 1617 MSC, Raleigh, NC 27699-1617 24b. For Injection Wells: Copy to DWR, Underground Injection Control (IUC) Program, 1636 MSC, Raleigh, NC 27699-1636 24c. For Water Supply and Open-Loop Geothermal Return Wells: Copy to the county environmental health department of the county where installed 24d. For Water Wells producing over 100,000 GPD: Copy to DWR, CCPCUA Permit Program, 1611 MSC, Raleigh, NC 27699-1611 Mike Radford 4267-A Overburden Bridger Drilling 0.0 5.7 Sch 40 5.7 35.7 0.010 0.0 Grout 3.3 Bentonite 4.4 DSI #2 5.0 Pea Gravel See Boring Log for LG-14.1/8/24 LG-14 Shotwell C&D Landfill 9226-CDLF-2020 4724 Smithfield Rd, Wendell, 27591 Wake 1761682890 Landfill Gas Monitoring Well 35.7263182 78.4362733 1/23/24 35.9 NA / Gas Well 8.25 Hollow Stem Auger 45.036.4 PVC Sch 40 PVC 2 2 3.3 4.4 5.0 45.0 Pour Pour Pour Pour APPENDIX E Soil Laboratory Testing Results Tested By: DM Checked By: DM/ML Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Brown poorly graded SAND #4 #10 #20 #40 #60 #100 #140 #200 100.0 93.3 4.3 0.3 0.3 0.2 0.2 0.2 1.9184 1.8151 1.4480 1.3339 1.1279 0.9761 0.9213 1.57 0.95 SP Meridian Waste Acquistions Shotwell C&D Landfill Well Install 14374-10 Soil Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Filter Pack Sample Number: Filter Pack Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.0 6.7 93.0 0.1 0.26 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report Tested By: ML Checked By: DM/ML Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Grey silty SAND 3/8 #4 #10 #20 #40 #60 #100 #140 #200 100.0 99.9 98.7 88.9 72.4 57.6 42.0 33.1 27.9 0.9053 0.7048 0.2711 0.1950 0.0881 Meridian Waste Acquistions Shotwell C&D Landfill Well Install 14374-10 Soil Description Atterberg Limits Coefficients Classification Remarks Source of Sample: MW Depth: 40-41 Sample Number: MW-1AR Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.1 1.2 26.3 44.5 27.96 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report SAMPLE ID. DEPTH (Ft) WET WEIGHT (g) DRY WEIGHT (g)MOISTURE CONTENT % MW-1AR 40.0 41.0 447.5 343.5 30.3 JOB NAME: TESTED BY: ML JOB NO.: CHECKED BY: DM DATE: 1/23/2024 LABORATORY MOISTURE CONTENT DETERMINATION (ASTM D2216) Shotwell C&D Landfill Well Install 14374-10 APPENDIX F Groundwater Monitoring Well Development Log MONITORING WELL DEVELOPMENT LOG DATE 1/10/24 & 1/11/24 TOTAL WELL DEPTH (TWD); TOP OF CASING =53.3 1/100 ft PERSONNEL TCG DEPTH TO GROUND WATER (DGW) =39.83 1/100 ft SITE Shotwell C&D Landfill - Wendell, NC LENGTH OF WATER COLUMN (LWC) = TWD - DGW =13.5 1/100 ft JOB #J23-14374-10 1 CASING VOLUME (CV) = LWC x 0.17 =2.3 gallons WELL ID MW-1AR NUMBER CV REMOVED = 12 CV TOTAL VOLUME OF WATER REMOVED =27.5 gallons METHOD OF WELL DEVELOPMENT =Pump & Surge WELL YIELD = Low/Moderate TIME ELAPSED VOLUME PURGED SURGE WATER pH SPECIF. COND.TURBIDITY COLOR PURGING DEV. TIME (hrs)event (gallons)total (gallons)TEMP (C)(units)(mmho/cm)(NTU)(subjective)METHOD 1/10/2024 13:42 0 hr 0 min 0.0 0.0 Yes 19.0 7.45 262.9 >1000 Brown Pump 1/10/2024 13:52 0 hr 10 min 2.5 2.5 -20.3 7.56 219.3 >1000 Brown Pump 1/10/2024 14:05 0 hr 23 min 2.5 5.0 Yes 19.7 7.36 156.30 459 Tan/Cloudy Pump 1/10/2024 14:53 1 hr 11 min 2.5 7.5 Yes 18.1 7.31 147.6 >1000 Brown Pump 1/10/2024 15:17 1 hr 35 min 2.5 10.0 Yes 18.5 7.01 127.6 657 Cloudy Pump 1/10/2024 15:42 2 hr 0 min 2.5 12.5 Yes 18.0 6.86 123.8 247 Cloudy Pump 1/10/2024 16:16 2 hr 34 min 2.5 15.0 Yes 18.3 6.6 119.9 >1000 Cloudy Pump 1/10/2024 16:32 2 hr 50 min 1.3 16.3 Yes 17.8 6.77 1217 884 Cloudy Pump 1/10/2024 16:49 3 hr 7 min 1.3 17.5 -18.1 6.78 107.8 233 Cloudy Pump 1/10/2024 17:30 3 hr 48 min 2.5 20.0 Yes ----Cloudy Pump 1/11/2024 8:10 0 hr 0 min 0.0 20.0 Yes 14.5 6.76 115.9 >1000 Brown/Cloudy Pump 1/11/2024 8:27 0 hr 17 min 2.5 22.5 -12.1 7.25 108.3 149 Clear Pump 1/11/2024 8:51 0 hr 41 min 2.5 25.0 -13.0 6.69 103.1 39.0 Clear Pump 1/11/2024 9:40 1 hr 30 min 2.5 27.5 -13.3 6.51 104.9 9.8 Clear Pump MW-1AR 14374-10 Development Log.xlsx Bunnell-Lammons Engineering, Inc. Greenville, SC