HomeMy WebLinkAboutSLAS7418_PERMIT_RENEWAL_2024January 25, 2024
Jamey Way
TST Cleaning Services
1283 Horse Pen Swamp Rd
Washington, NC 27889
RE: SLAS-74-18 Permit Issuance
TST Cleaning Services
Clearview Lane in Pitt County
Dear Mr. Way:
The NC Division of Waste Management has reviewed and approved your application for a permit tooperate a Septage
Land Application Site (FID1826799)in PittCounty. Your application has been approved in accordance with NC Septage
Management Rules and your permit, SLAS-74-18, is attached.
Please read all permit conditions carefully. The nutrient management and soil erosion and runoff control plans you
submitted have been incorporated into your permit. Do not exceed the maximum annual application rate listed within
Permit Condition 7 or the monthly application rates listed in your nutrient management plan. This permit shall expire
on January 25th, 2034. An application for permit renewal must be submitted ninety (90) days prior to permit
expiration.
Violations to NC Septage Management Rules or this permit could subject you to administrative penalties of up to
$15,000 per violation per day. If you have any questions concerning your permit or septage in general, please do not
hesitate to contact me at (919) 707-8285. When communicating to the Division about this permit, please refer to it
as "SLAS-74-18."
Sincerely,
Jeffrey Bullard, Environmental Program Consultant
Division of Waste Management, NCDEQ
Attachment
copies: Central Files
Pitt County Health Department
ey Bullard Environmental Program Co
Facility Permit No.: SLAS-74-18
TST Cleaning Services
Permit to Operate
January 25, 2024
Page 1 of 4
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENTAL QUALITY
DIVISION OF WASTE MANAGEMENT
SOLID WASTE SECTION
PERMIT TO OPERATE A SEPTAGE LAND
APPLICATION SITE
PERMIT #: SLAS-74-18
TST Cleaning Services
Jamey Way, Owner
1283 Horse Pen Swamp Rd
Washington, NC 27889
is hereby permitted to operate Septage Land Application Site with permit # SLAS-74-18 located on SR 1409 in
Pitt County at approximate position 35.77556° N latitude and -77.47382° E longitude. This site is permitted only
for operations that are conducted in accordance with the representations made in the approved application, with
all conditions attached to this permit, and with all of the provisions of 15A NCAC 13B.0800 -- Septage
Management. Failure to operate as permitted may result in the Department suspending or revoking this permit,
initiating action to enjoin the unpermitted operation, imposing administrative penalties, or invoking any other
remedy as provided in Chapter 130A, Article 1, Part 2 of the North Carolina General Statutes.
This permit shall be reviewed annually to determine if soil test results and management activities are in
compliance with the Septage Management Rules and the conditions of this permit. Modifications, where
necessary, shall be made in accordance with rules in effect at the time of review.
____________________________
Perry Sugg
Environmental Compliance Branch Head
Solid Waste Section
Division of Waste Management, NCDEQ
Wm Perry
Sugg
Digitally signed by Wm
Perry Sugg
Date: 2024.01.25 15:00:55
-05'00'
Facility Permit No.: SLAS-74-18
TST Cleaning Services
Permit to Operate January 25, 2024
Page 2 of 4
CONDITIONS OF OPERATING PERMIT
1. This permit shall become void if the soils fail to adequately assimilate the septage and
shall be rescinded unless the site is maintained and operated in a manner which will
protect the assigned water quality standards of both surface and ground waters.
2. This site shall be operated and maintained in accordance with the nutrient management
plan, see Attachment A, submitted by Jamey Way and approved by the Division of Waste
Management. The 10.9-acre site shall be split into two fields identified as Field 1 with
6.7 acres and Field 2 with 4.2 acres. The fields shall remain established in hybrid
bermudagrass. The fields shall be overseeded in rye, wheat, small grain mix, or annual
ryegrass in October or early November. The planting and harvesting of the crops shall
follow the approved nutrient management plan. Areas that develop less than 80% cover
in bermudagrass will be re-seeded in bermudagrass as noted in the approved nutrient
management plan. The 30-day waiting period between the last application of septage,
and the harvest of a crop shall be met by alternating septage applications between the
fields or utilizing an alternative disposal location such as a permitted septage detention
facility or wastewater treatment plant. All discharges shall occur within the permitted
area and shall be consistent with the crop rotation in the approved plan.
3. This site shall be operated and maintained in accordance with the erosion and runoff
control plan, see Attachment A, submitted by Jamey Way in such a manner as to prevent
the migration of wastes off the designated waste receiving site. Any site improvements
noted in the plan must be installed within 30 days of plan approval. The installation of
groundwater monitoring wells shall be required as deemed necessary by the Division.
4. The issuance of this permit does not preclude the Permittee from complying with any
and all statutes, rules, regulations, or ordinances that may be imposed by other local,
state, and federal government agencies which have jurisdiction. It is the responsibility
of the Permittee to be in compliance with the Federal Regulations listed in the Code of
Federal Regulations, 40 CFR Part 503.
5. This permit may be modified or reissued at any time to incorporate any conditions,
limitations and/or monitoring requirements the Division deems necessary to adequately
protect the environment and public health.
Facility Permit No.: SLAS-74-18
TST Cleaning Services
Permit to Operate January 25, 2024
Page 3 of 4
6. This site is only permitted for the land application of domestic septage and grease
septage. The pH of domestic septage shall be raised to 12 or higher by alkali addition
and, without the addition of additional alkali, shall remain at 12 or higher for 30 minutes
prior to land application as per 15A NCAC 13B .0842(c)(1). The pH of grease septage or
grease septage mixed with domestic septage shall be raised to 12 or higher by alkali
addition and, without the addition of additional alkali, shall remain at 12 or higher for 2
hours prior to land application as per 15A NCAC 13B .0842(c)(2). Grease septage shall be
diluted as required by 15A NCAC 13B .0842(a)(14) when applied over perennial
vegetation.
7. This site contains approximately 10.9 acres that are available for land application of
septage. The maximum annual application rate shall be 50,000 gallons per acre per
year. At this application rate, a maximum annual volume of 545,000 gallons may be
applied to this site. The maximum annual application rate assumes equal septage
distribution, on an annual basis, over the entire permitted area. Application rates to each
approved disposal field shall not exceed the maximum annual application rate or the
monthly application rates listed in the approved nutrient management plan.
8. An approved septage detention facility with a minimum design capacity of 10,900 gallons
shall be available prior to operation of this site as per 15A NCAC 13B .0838(a) unless an
approved wastewater treatment plant is available for use during periods of adverse
weather. The storage capacity may be adjusted if it is demonstrated during the operation
of the site that this volume of storage is inadequate.
9. Only the area designated on the attached site map shall be utilized for septage disposal.
Each load of septage discharged at the site shall be distributed from a moving vehicle in
such a manner that there is no standing water when the discharge is complete.
10. Septage shall not be applied during any precipitation event, or if there is standing water
on the soil surface, if the soil surface is frozen, or if the soil surface is snow covered. The
Permittee shall consider pending weather conditions when making the decision to land
apply in order to prevent any discharge of septage outside of the permitted boundary.
11. Septage shall not be applied during periods of high soil moisture. Septage applications
that will result in ruts greater than three inches in the soil surface are prohibited.
12. Any discharge of septage outside of the permitted boundaries via runoff, aerial drift, etc.
is prohibited.
Facility Permit No.: SLAS-74-18
TST Cleaning Services
Permit to Operate January 25, 2024
Page 4 of 4
13. This permit shall become void unless the land application activities are carried out in
accordance with the conditions of this permit and in the manner approved by this
Division. No one other than the Permittee or an employee of the firm named in this
permit shall discharge septage at this site without prior appropriate notification and
written approval from the Division.
14. Prior to any transfer of this land, a notice shall be given to the new owner that gives full
details of the materials applied or incorporated at this site. The Division shall be notified
prior to site closure. This permit is non-transferable.
15. This permit shall expire on January 25, 2034. An application for permit renewal shall be
submitted at least ninety (90) days prior to the permit renewal date in accordance with
15A NCAC 13B .0840(g) and (i). When necessary, an application for permit modification
shall be submitted for any proposed change in accordance with 15A NCAC 13B .0840(h)
and (i). Along with the application for permit renewal or modification, septage
application records for the time this permit was valid shall be submitted.
16. Records shall be kept in accordance with 15A NCAC 13B .0842(e)(1) and the Code of
Federal Regulations, 40 CFR Part 503.17(b) to document all septage applications to the
site. These records shall be made available to a representative of the Division upon
request.
17. Any duly authorized officer, employee, or representative of the Division may, upon
presentation of credentials, enter and inspect any property, premises, or place on or
related to the disposal site and facility at any reasonable time for the purpose of
determining compliance with this permit; may inspect or copy any records that must be
kept under the conditions of this permit; or may obtain samples of groundwater, surface
water, or leachate.
18. Field separations in the nutrient management plan and all pertinent setbacks shall be
clearly located on the site. Boundaries of the permitted septage land application fields
shall be clearly marked on the ground.
19. The areas that can be used for land application of septage shall be maintained to meet
the minimum setback distances as described in 15A NCAC 13B .0841(d) such as 500
feet from any existing wells, residences, places of business, or places of public
assembly. Also, septage shall not be disposed of within 50 feet of any property line,
within 100 feet of any ditch, or within 200 feet of any surface water unless specified
otherwise.
Attachment A
Approved NMP
1/25/24
Jeffrey Bullard