Loading...
HomeMy WebLinkAbout4101_Guilford_CityHighPoint_Riverdale_MSWLF_Seaboard_Dec23LFG_FID1826122_20240110DocuSign Envelope ID: D733FD5B-BD4C-4018-9E59-13CDA7D139B5 DENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Smith Gardner, Inc. Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Seth C. Rickerts, PG E-mail: seth@smithgardnerinc.com Phone: (919) 828 - 0577 x135 NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) High Point Riverdale Closed MSW Riverdale Drive, High Point, NC 41-01 .0500 December 6, 2023 Landfill Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑X Detection Monitoring ❑ Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Seth C. Rickerts, PG Project Geologist (919) 828 - 0577 x135 a�mwjlative Name (Print) Title (Area Code) Telephone Number 1/10/2024 Affix NC Licensed/ Professional Geologist Seal Date 14 N. Boylan Ave, Raleigh, NC 27603 Facility Representative Address F-1370 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 a` yi. nl.}{�rrr. rr r rEN /10 2a 2758 C. R%r-_ 00 DocuSign Envelope ID: D733FD5B-BD4C-4018-9E59-13CDA7D139B5 This page intentionally left blank. DocuSign Envelope ID: D733FD5B-BD4C-4018-9E59-13CDA7D139B5 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: City of High Point Closed Riverdale Landfill Date of Sampling: 12/06/2023 Name and Position of Sample Collector: Permit Number: 41-01 _ NC Landfill Rule (.0500 or .1600): .0500 Kyle M. Bonnett - Environmental Technician Type and Serial Number of Gas Meter: GEM 5000, G506472 Date and Time of Field Calibration: 12/06/2023, 1215 Calibration Date of Gas Meter: 01/2023 Type of Field Calibration Gas (15115 or 35/50): 35/50 Expiration Date of Field Calibration Gas Canister: 10/2024 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 50 F Barometric Pressure: 29.39 in Hg General Weather Conditions: Sunny Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 Locafion or LFG lVell ID Sample Tube Purge Time Time Pumped (s) Initial °,ZEL Stabized °,,ZEL Of CH4 by Volume %02 %CO2 Notes H2 S ppm 1-1 >60s 1407 >60s 0 0 0.0 19.0 2.0 0 LFG 3 - - - - - LFG 4 >60s 1418 >60s 0 0 0.0 19.1 2.3 0 LFG 5 >60s 1420 >60s 0 0 0.0 18.4 2.8 0 LFG 6 >60s 1422 >60s 12 12 0.6 18.2 3.2 0 LFG 7 >60s 1445 >60s 470 470 23.5 8.0 16.9 0 7-1 >60s 1447 >60s 66 66 3.3 18.1 4.2 0 7-2 >60s 1443 >60s 0 0 0.0 17.9 3.5 0 7-3 >60s 1442 >60s 0 0 0.0 20.5 0.0 0 7-4 >60s 1441 >60s 588 588 29.4 3.3 26.1 0 LFG 8 >60s 1437 >60s 164 164 8.2 12.4 10.8 0 LFG 8A >60S 1438 >60S 1208 1208 60.4 0.2 33.6 4 LFG 8B >60s 1439 >60s 0 0 0.0 20.6 0.3 0 8-1 >60s 1436 >60s 566 566 28.3 7.3 24.3 0 8-2 >60s 1435 >60s 864 864 43.2 0.4 37.8 0 8-3 >60s 1434 >60s 752 752 37.6 1.6 34.9 0 8-4 >60s 1452 >60s 950 950 47.5 3.1 33.6 0 8-5 >60s 1453 >60s 0 0 0.0 20.2 0.5 0 LFG 9 >60s 1455 >60s 0 0 0.0 20.8 0.0 0 9-1 >60s 1456 >60s 24 24 1.2 19.6 1.6 0 LFG 10 >60s 1458 >60s 0 0 0.0 18.4 3.0 0 Old Maint Bldg >60s 1423 >60s 0 0 0.0 20.7 0.0 0 Electrical Shop >60s 1425 >60s 0 0 0.0 20.7 0.0 0 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. DocuS��ippgned by: Ddx 10B56EEF9EA34EL7 SIGNATURE Environmental Technician TITLE DocuSign Envelope ID: D733FD5B-BD4C-4018-9E59-13CDA7D139B5 This page intentionally left blank. DocuSign Envelope ID: D733FD5B-BD4C-4018-9E59-13CDA7D139B5 Q O M C) M O N X E C 0 I L LM U N 0 H Z_ U Z C O d L U O a_ s■ � r � jjjj! l 4 1 0. i 's - • N. am ■ CIO i►r�.� "r ► -7y4 1� ''r O • r + • Pl- • •l • •#• -cn LU