Loading...
HomeMy WebLinkAboutWA-55_3515_CA_RPTS_20230928_LIMITED GWS WithersRavenel Our People. Your Success.    115 MacKenan Drive | Cary, NC 27511 t: 919.469.3340 | f: 919.467.6008 | www.withersravenel.com | License No. F-1479 Asheville | Cary | Charlotte | Greensboro | Lumberton | Pittsboro | Raleigh | Southern Pines | Wilmington    September 28, 2023    State of North Carolina  Department of Environment Quality   Federal & State Lead Program  Division of Waste Management‐Underground Storage Tank Section   1646 Mail Service Center  Raleigh, North Carolina 27699‐1646    Attn: Ms. Liz Price    Re: Letter Report – Limited Groundwater Sampling   Former McCoy’s Store  Three (3) former 550‐gallon gasoline USTs   Facility ID: 0‐0‐0011826  3238 NC Highway 55  Jasper, Craven County, North Carolina  Groundwater Incident Number: 3515   WR Project Number:  23‐0307‐BR    Ms. Price:    WithersRavenel, Inc. (WR) has completed this Letter Report to document the limited groundwater  sampling event described in our proposal number TA-02 for the above referenced facility, approved by the Federal & State Lead Program on July 26, 2023 under Contract # N70522-C. WithersRavenel  mobilized to the subject site on September 8, 2023 for the purposes of gauging, purging and  sampling monitoring wells MW‐3, MW‐4, MW‐8 and MW‐10 (Figure 1).      Groundwater Sampling    Prior to the purging and sampling of the monitoring wells as described below, each well was  gauged using a decontaminated electronic water level indicator.  In performance of well gauging,  no free product/LNAPL was detected in any of the wells measured.  Results of well gauging are  summarized below:              Well ID Depth to Product (ft) Depth to Water (ft) Product Thickness (ft)  MW‐3  ‐‐‐ 8.61  ‐‐‐  MW‐4  ‐‐‐ 8.71  ‐‐‐  MW‐8  ‐‐‐ 8.32  ‐‐‐  MW‐10  ‐‐‐ 7.94  ‐‐‐  WithersRavenel Our People. Your Success.  Letter Report – Limited Groundwater Sampling        Former McCoy’s Store  September 2023  Page 2 of 2      Following gauging, monitoring wells MW‐3, MW‐4, MW‐8 and MW‐10 were purged with  dedicated, disposable polyethylene (PE) bailers.  Following purging and adequate recharge of  groundwater within the wells, samples were decanted directly into pre‐preserved laboratory  grade sample containers provided by Waypoint Analytical, LLC (Waypoint) for analysis of VOCs  by Standard Method (SM) 6200B.    Laboratory Results    Analytical results for groundwater samples obtained from site monitoring wells September  showed the following:      Several targeted compounds were reported in the samples from MW‐3, MW‐4, MW‐8 and  MW‐10 at concentrations exceeding their NC 2L Standards.     Benzene was reported in the samples collected from MW‐3 and MW‐4 at concentrations  exceeding the GCL for the compound.      Analytical results from the September 2023 groundwater sampling event are included in Table  B‐4 (Abbreviated).  Field notes and site photos are included as Attachment A, while the  laboratory analytical report is provided as Attachment B.    WR completed a receptor survey update at the site in association with the current TA.  Results  of the receptor survey update are outlined under a separate cover.  Results of the update  revealed that no active water supply wells are located within a 1,500‐ft radius of the site, while  all occupied properties within that radius are connected to the Craven County municipal water  system.      WR appreciates the opportunity to be of service to the Federal & State Lead Program.  Should  you have any questions regarding the attached, please do not hesitate to contact  WithersRavenel at (919) 469‐3340.    Cordially,  WithersRavenel     Kevin B. Buchanan G. Matthew James, P.G.  Project Manager Director of Geosciences                                  FIGURE                                RESIDENCEMW-9APPROXIMATE EXCAVATION LIMITS65 FT LONG X 46 FT WIDE (MAXIMUM) X 5 FT DEEP (AVERAGE)741.39 TONS REMOVEDCARPORTFORMERMCCOY'SSTOREMW-1RMW-13MW-7MW-4MW-3MW-5MW-12MW-8MW-6MW-10MW-2FORMER MCCOY'S STORE INCIDENT # 35153238 NC HIGHWAY 55JASPER, CRAVEN COUNTY, NC KBB MJ DRAWN BY: 09/11/2023 23-0307-BR 1 SCALE:FIGURE NO.: PROJECT NO.:DATE:APPROVED BY:SITE MAPWithersRavenel Engineers | Planners | Surveyors 115 MacKenan Drive | Cary, NC 27511 | t: 919.469.3340 | license #: F-1479 | www.withersravenel.com 1"=30 'LEGENDTYPE II MONITORING WELL LOCATIONFORMER UST LOCATIONNOTES:1. FORMER UST LOCATIONS ARE APPROXIMATE.2. MONITORING WELL MW-11 NOT SHOWN.GRAPHIC SCALE1 inch = 30 ft.0301560                           TABLE B‐4 (Abbreviated)  CalculatedBenzenen-Butylbenzenesec-ButylbenzeneEthylbenzeneIsopropylbenzeneMethyl tert-butyl ether (MTBE)Naphthalenen-PropylbenzeneStyreneToluene1,2,4-Trimethylbenzene1,3,5-TrimethylbenzeneTotal Xylenes71-43-2 104-51-8 135-98-8 100-41-4 98-82-8 1634-04-4 91-20-3 103-65-1 100-42-5 108-88-3 95-63-6 108-67-8 NAMW-3 9/8/202332400221 82.1 4120 279 116 1840 938 64.6 42900 6700 1870 20800MW-4 9/8/202317200<50.0 <50.02780 121<100676 311<50.036900 2200 566 13800MW-8 9/8/2023 1270<50.0 <50.01280<50.0 <100457 97.6<50.03840 1000 281 4550MW-10 9/8/2023 240<5.00 <5.0076.4<5.00 <10.0 <10.08.75<5.0093.7 52.7 8.22 2031 70 70 600 70 20 6 70 70 600 400 400 5005,000 5,900 8,800 80,000 30,500 20,000 6,000 26,100 70,000 260,000 28,500 24,100 50,000Notes:1)2)3)4)Result= Result Exceeds Laboratory Detection LimitsResult= Result Exceeds 2L StandardResult= Result Exceeds GCL ValueNC 2L Standard GCLs for GroundwaterAll results provided in ug/L (micrograms per liter) or parts per billionCompounds analyzed for by laboratory but not listed were not detected above laboratory detection limits. See the laboratory report included in the Appendix for a full list of constituents. NC 2L Standard - North Carolina Groundwater Quality Standard as per NC Administrative Code 15A NCAC 02L (Comprehensive Tables for Corrective Action Guidelines, September 2022).GCLs for Groundwater = NCDENR UST Section Gross Contamination Levels for Groundwater (Comprehensive Tables for Corrective Action Guidelines, September 2022).Analytical MethodSampleIDDateCollectedTABLE B-4ASUMMARY OF GROUNDWATER ANALYTICAL RESULTS (ABBREVIATED)(Former) McCoy's StoreIncident Number: 35153238 NC Highway 55Jasper, Craven County, North CarolinaPage 1 of 1                         ATTACHMENT A    FIELD NOTES & SITE PHOTOGRAPHS       PHOTO 1  MW‐3       PHOTO 2  MW‐4       PHOTO 3  MW‐8     PHOTO 4  MW‐10                              ATTACHMENT B    LABORATORY REPORT        Laboratory's liability in any claim relating to analyses performed shall be limited to, at laboratory's option, repeating the analysis in question at laboratory's expense, or the refund of the charges paid for performance of said analysis.   9/18/2023 Withers & Ravenel Matt James 115 Mackenan Dr. BUILDING 117 Cary, NC, 27511 Ref: Analytical Testing Lab Report Number: 23-255-0053 Client Project Description: Former McCoy's 23-307-BR Dear Matt James: Waypoint Analytical, LLC (Charlotte) received sample(s) on 9/12/2023 for the analyses presented in the following report. The above referenced project has been analyzed per your instructions. The analyses were performed in accordance with the applicable analytical method. The analytical data has been validated using standard quality control measures performed as required by the analytical method. Quality Assurance, method validations, instrumentation maintenance and calibration for all parameters were performed in accordance with guidelines established by the USEPA (including 40 CFR 136 Method Update Rule May 2021) unless otherwise indicated. Certain parameters (chlorine, pH, dissolved oxygen, sulfite...) are required to be analyzed within 15 minutes of sampling. Usually, but not always, any field parameter analyzed at the laboratory is outside of this holding time. Refer to sample analysis time for confirmation of holding time compliance. The results are shown on the attached Report of Analysis(s). Results for solid matrices are reported on an as- received basis unless otherwise indicated. This report shall not be reproduced except in full and relates only to the samples included in this report. Please do not hesitate to contact me or client services if you have any questions or need additional information. Sincerely, Angela D Overcash Senior Project Manager Page 1 of 36 Certification Summary Laboratory ID: WP CNC: Waypoint Analytical Carolina, Inc. (C), Charlotte, NC State Program Lab ID Expiration Date 07/31/202437735State ProgramNorth Carolina 12/31/2023402State ProgramNorth Carolina 07/31/202499012State ProgramSouth Carolina 12/31/202399012State ProgramSouth Carolina Page 1 of 1 00016/23-255-0053 Page 2 of 36 Report Number: Sample Summary Table Client Project Description: 23-255-0053 Former McCoy's 23-307-BR Lab No Client Sample ID Matrix Date Collected Date Received 09/08/2023 11:30Aqueous 94845 MW-3 09/12/2023 16:30 09/08/2023 11:40Aqueous 94846 MW-4 09/12/2023 16:30 09/08/2023 11:50Aqueous 94847 MW-8 09/12/2023 16:30 09/08/2023 12:00Aqueous 94848 MW-10 09/12/2023 16:30 Page 3 of 36 Summary of Detected Analytes QualifiersAnalyzedUnitsResult Report Number: Client Sample ID Method Parameters Lab Sample ID 23-255-0053 Report Limit Project:Former McCoy's V 94845MW-3 32400 09/15/2023 11:436200BBenzeneµg/L 500 221 09/14/2023 03:506200Bn-Butylbenzene µg/L 50.0 82.1 09/14/2023 03:506200Bsec-Butyl benzene µg/L 50.0 4120 09/14/2023 03:506200BEthylbenzeneµg/L 50.0 279 09/14/2023 03:506200BIsopropylbenzeneµg/L 50.0 116 09/14/2023 03:506200BMethyl tert-butyl ether (MTBE)µg/L 100 1840 09/14/2023 03:506200BNaphthaleneµg/L 100 938 09/14/2023 03:506200Bn-Propylbenzene µg/L 50.0 64.6 09/14/2023 03:506200BStyreneµg/L 50.0 42900 09/15/2023 11:436200BTolueneµg/L 500 6700 09/14/2023 03:506200B1,2,4-Trimethylbenzene µg/L 50.0 1870 09/14/2023 03:506200B1,3,5-Trimethylbenzene µg/L 50.0 6570 09/14/2023 03:506200Bo-Xylene µg/L 50.0 14200 09/14/2023 03:506200Bm,p-Xylene µg/L 100 20800 09/14/2023 03:506200BXylene (Total)µg/L 50.0 V 94846MW-4 17200 09/15/2023 10:006200BBenzeneµg/L 500 2780 09/14/2023 00:576200BEthylbenzeneµg/L 50.0 121 09/14/2023 00:576200BIsopropylbenzeneµg/L 50.0 676 09/14/2023 00:576200BNaphthaleneµg/L 100 311 09/14/2023 00:576200Bn-Propylbenzene µg/L 50.0 36900 09/15/2023 10:006200BTolueneµg/L 500 2200 09/14/2023 00:576200B1,2,4-Trimethylbenzene µg/L 50.0 566 09/14/2023 00:576200B1,3,5-Trimethylbenzene µg/L 50.0 4270 09/14/2023 00:576200Bo-Xylene µg/L 50.0 9490 09/14/2023 00:576200Bm,p-Xylene µg/L 100 13800 09/14/2023 00:576200BXylene (Total)µg/L 50.0 V 94847MW-8 1270 09/14/2023 01:216200BBenzeneµg/L 50.0 1280 09/14/2023 01:216200BEthylbenzeneµg/L 50.0 457 09/14/2023 01:216200BNaphthaleneµg/L 100 97.6 09/14/2023 01:216200Bn-Propylbenzene µg/L 50.0 3840 09/14/2023 01:216200BTolueneµg/L 50.0 1000 09/14/2023 01:216200B1,2,4-Trimethylbenzene µg/L 50.0 281 09/14/2023 01:216200B1,3,5-Trimethylbenzene µg/L 50.0 2210 09/14/2023 01:216200Bo-Xylene µg/L 50.0 Page 4 of 36 Summary of Detected Analytes QualifiersAnalyzedUnitsResult Report Number: Client Sample ID Method Parameters Lab Sample ID 23-255-0053 Report Limit Project:Former McCoy's V 94847MW-8 2340 09/14/2023 01:216200Bm,p-Xylene µg/L 100 4550 09/14/2023 01:216200BXylene (Total)µg/L 50.0 V 94848MW-10 240 09/15/2023 07:006200BBenzeneµg/L 5.00 76.4 09/15/2023 07:006200BEthylbenzeneµg/L 5.00 8.75 09/15/2023 07:006200Bn-Propylbenzene µg/L 5.00 93.7 09/15/2023 07:006200BTolueneµg/L 5.00 52.7 09/15/2023 07:006200B1,2,4-Trimethylbenzene µg/L 5.00 8.22 09/15/2023 07:006200B1,3,5-Trimethylbenzene µg/L 5.00 90.5 09/15/2023 07:006200Bo-Xylene µg/L 5.00 112 09/15/2023 07:006200Bm,p-Xylene µg/L 10.0 203 09/15/2023 07:006200BXylene (Total)µg/L 5.00 Page 5 of 36   Client: Withers & Ravenel CASE NARRATIVE Project: Former McCoy's Lab Report Number: 23-255-0053 Date: 9/15/2023 Volatile Organic Compounds - GC/MS Method 6200B Analyte: Vinyl acetate QC Batch No: V37835/V37833 Relative Percent Difference (RPD) for the duplicate analysis was outside of the allowable QC limits. Page 6 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-3 94845 Matrix: 9/8/2023 11:30 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <1000 µg/L 1000Acetone 100 09/14/23 03:50 6200BMSA 32400 µg/L 500Benzene 1000 09/15/23 11:43 6200BENM <50.0 µg/L 50.0Bromobenzene 100 09/14/23 03:50 6200BMSA <100 µg/L 100Bromochloromethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Bromodichloromethane 100 09/14/23 03:50 6200BMSA <500 µg/L 500Bromoform 100 09/14/23 03:50 6200BMSA <100 µg/L 100Bromomethane 100 09/14/23 03:50 6200BMSA 221 µg/L 50.0n-Butylbenzene 100 09/14/23 03:50 6200BMSA 82.1 µg/L 50.0sec-Butyl benzene 100 09/14/23 03:50 6200BMSA <200 µg/L 200tert-Butyl benzene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Carbon Tetrachloride 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Chlorobenzene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Chlorodibromomethane 100 09/14/23 03:50 6200BMSA <100 µg/L 100Chloroethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Chloroform 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Chloromethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.02-Chlorotoluene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.04-Chlorotoluene 100 09/14/23 03:50 6200BMSA <200 µg/L 2001,2-Dibromo-3-Chloropropane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,2-Dibromoethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Dibromomethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,2-Dichlorobenzene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,3-Dichlorobenzene 100 09/14/23 03:50 6200BMSA Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 7 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-3 94845 Matrix: 9/8/2023 11:30 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <50.0 µg/L 50.01,4-Dichlorobenzene 100 09/14/23 03:50 6200BMSA <500 µg/L 500Dichlorodifluoromethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,1-Dichloroethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,2-Dichloroethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,1-Dichloroethene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0cis-1,2-Dichloroethene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0trans-1,2-Dichloroethene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,2-Dichloropropane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,3-Dichloropropane 100 09/14/23 03:50 6200BMSA <200 µg/L 2002,2-Dichloropropane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,1-Dichloropropene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0cis-1,3-Dichloropropene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0trans-1,3-Dichloropropene 100 09/14/23 03:50 6200BMSA <20000 µg/L 20000Ethanol 100 09/14/23 03:50 6200BMSA 4120 µg/L 50.0Ethylbenzene 100 09/14/23 03:50 6200BMSA <300 µg/L 300Hexachlorobutadiene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Di-Isopropyl Ether (DIPE)100 09/14/23 03:50 6200BMSA 279 µg/L 50.0Isopropylbenzene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.04-Isopropyl toluene 100 09/14/23 03:50 6200BMSA <100 µg/L 1002-Hexanone 100 09/14/23 03:50 6200BMSA <500 µg/L 500Methyl Ethyl Ketone (MEK)100 09/14/23 03:50 6200BMSA <200 µg/L 200Methylene Chloride 100 09/14/23 03:50 6200BMSA 116 µg/L 100Methyl tert-butyl ether (MTBE)100 09/14/23 03:50 6200BMSA Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 8 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-3 94845 Matrix: 9/8/2023 11:30 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <100 µg/L 1004-Methyl-2-Pentanone 100 09/14/23 03:50 6200BMSA 1840 µg/L 100Naphthalene 100 09/14/23 03:50 6200BMSA 938 µg/L 50.0n-Propylbenzene 100 09/14/23 03:50 6200BMSA 64.6 µg/L 50.0Styrene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,1,1,2-Tetrachloroethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,1,2,2-Tetrachloroethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Tetrachloroethene 100 09/14/23 03:50 6200BMSA 42900 µg/L 500Toluene 1000 09/15/23 11:43 6200BENM <50.0 µg/L 50.01,2,3-Trichlorobenzene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,2,4-Trichlorobenzene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,1,1-Trichloroethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,1,2-Trichloroethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Trichloroethene 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Trichlorofluoromethane 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.01,2,3-Trichloropropane 100 09/14/23 03:50 6200BMSA 6700 µg/L 50.01,2,4-Trimethylbenzene 100 09/14/23 03:50 6200BMSA 1870 µg/L 50.01,3,5-Trimethylbenzene 100 09/14/23 03:50 6200BMSA <500 µg/L 500Vinyl Acetate 100 09/14/23 03:50 6200BMSA <50.0 µg/L 50.0Vinyl Chloride 100 09/14/23 03:50 6200BMSA 14200 µg/L 100m,p-Xylene 100 09/14/23 03:50 6200BMSA 6570 µg/L 50.0o-Xylene 100 09/14/23 03:50 6200BMSA Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 9 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-3 94845 Matrix: 9/8/2023 11:30 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF 20800 µg/L 50.0Xylene (Total)100 09/14/23 03:50 6200B Surrogate: 4-Bromofluorobenzene 98.4 Limits: 70-130%09/14/23 03:50100 MSA V37835 Surrogate: Dibromofluoromethane 100 Limits: 70-130%09/14/23 03:50100 MSA V37835 Surrogate: 1,2-Dichloroethane - d4 93.0 Limits: 70-130%09/14/23 03:50100 MSA V37835 Surrogate: Toluene-d8 101 Limits: 70-130%09/14/23 03:50100 MSA V37835 Surrogate: 4-Bromofluorobenzene 100 Limits: 70-130%09/15/23 11:431000 ENM V37910 Surrogate: Dibromofluoromethane 100 Limits: 70-130%09/15/23 11:431000 ENM V37910 Surrogate: 1,2-Dichloroethane - d4 97.4 Limits: 70-130%09/15/23 11:431000 ENM V37910 Surrogate: Toluene-d8 99.4 Limits: 70-130%09/15/23 11:431000 ENM V37910 Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 10 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-4 94846 Matrix: 9/8/2023 11:40 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <1000 µg/L 1000Acetone 100 09/14/23 00:57 6200BMSA 17200 µg/L 500Benzene 1000 09/15/23 10:00 6200BENM <50.0 µg/L 50.0Bromobenzene 100 09/14/23 00:57 6200BMSA <100 µg/L 100Bromochloromethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Bromodichloromethane 100 09/14/23 00:57 6200BMSA <500 µg/L 500Bromoform 100 09/14/23 00:57 6200BMSA <100 µg/L 100Bromomethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0n-Butylbenzene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0sec-Butyl benzene 100 09/14/23 00:57 6200BMSA <200 µg/L 200tert-Butyl benzene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Carbon Tetrachloride 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Chlorobenzene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Chlorodibromomethane 100 09/14/23 00:57 6200BMSA <100 µg/L 100Chloroethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Chloroform 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Chloromethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.02-Chlorotoluene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.04-Chlorotoluene 100 09/14/23 00:57 6200BMSA <200 µg/L 2001,2-Dibromo-3-Chloropropane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,2-Dibromoethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Dibromomethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,2-Dichlorobenzene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,3-Dichlorobenzene 100 09/14/23 00:57 6200BMSA Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 11 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-4 94846 Matrix: 9/8/2023 11:40 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <50.0 µg/L 50.01,4-Dichlorobenzene 100 09/14/23 00:57 6200BMSA <500 µg/L 500Dichlorodifluoromethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,1-Dichloroethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,2-Dichloroethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,1-Dichloroethene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0cis-1,2-Dichloroethene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0trans-1,2-Dichloroethene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,2-Dichloropropane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,3-Dichloropropane 100 09/14/23 00:57 6200BMSA <200 µg/L 2002,2-Dichloropropane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,1-Dichloropropene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0cis-1,3-Dichloropropene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0trans-1,3-Dichloropropene 100 09/14/23 00:57 6200BMSA <20000 µg/L 20000Ethanol 100 09/14/23 00:57 6200BMSA 2780 µg/L 50.0Ethylbenzene 100 09/14/23 00:57 6200BMSA <300 µg/L 300Hexachlorobutadiene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Di-Isopropyl Ether (DIPE)100 09/14/23 00:57 6200BMSA 121 µg/L 50.0Isopropylbenzene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.04-Isopropyl toluene 100 09/14/23 00:57 6200BMSA <100 µg/L 1002-Hexanone 100 09/14/23 00:57 6200BMSA <500 µg/L 500Methyl Ethyl Ketone (MEK)100 09/14/23 00:57 6200BMSA <200 µg/L 200Methylene Chloride 100 09/14/23 00:57 6200BMSA <100 µg/L 100Methyl tert-butyl ether (MTBE)100 09/14/23 00:57 6200BMSA Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 12 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-4 94846 Matrix: 9/8/2023 11:40 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <100 µg/L 1004-Methyl-2-Pentanone 100 09/14/23 00:57 6200BMSA 676 µg/L 100Naphthalene 100 09/14/23 00:57 6200BMSA 311 µg/L 50.0n-Propylbenzene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Styrene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,1,1,2-Tetrachloroethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,1,2,2-Tetrachloroethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Tetrachloroethene 100 09/14/23 00:57 6200BMSA 36900 µg/L 500Toluene 1000 09/15/23 10:00 6200BENM <50.0 µg/L 50.01,2,3-Trichlorobenzene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,2,4-Trichlorobenzene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,1,1-Trichloroethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,1,2-Trichloroethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Trichloroethene 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Trichlorofluoromethane 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.01,2,3-Trichloropropane 100 09/14/23 00:57 6200BMSA 2200 µg/L 50.01,2,4-Trimethylbenzene 100 09/14/23 00:57 6200BMSA 566 µg/L 50.01,3,5-Trimethylbenzene 100 09/14/23 00:57 6200BMSA <500 µg/L 500Vinyl Acetate 100 09/14/23 00:57 6200BMSA <50.0 µg/L 50.0Vinyl Chloride 100 09/14/23 00:57 6200BMSA 9490 µg/L 100m,p-Xylene 100 09/14/23 00:57 6200BMSA 4270 µg/L 50.0o-Xylene 100 09/14/23 00:57 6200BMSA Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 13 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-4 94846 Matrix: 9/8/2023 11:40 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF 13800 µg/L 50.0Xylene (Total)100 09/14/23 00:57 6200B Surrogate: 4-Bromofluorobenzene 97.4 Limits: 70-130%09/14/23 00:57100 MSA V37835 Surrogate: Dibromofluoromethane 102 Limits: 70-130%09/14/23 00:57100 MSA V37835 Surrogate: 1,2-Dichloroethane - d4 96.8 Limits: 70-130%09/14/23 00:57100 MSA V37835 Surrogate: Toluene-d8 101 Limits: 70-130%09/14/23 00:57100 MSA V37835 Surrogate: 4-Bromofluorobenzene 103 Limits: 70-130%09/15/23 10:001000 ENM V37910 Surrogate: Dibromofluoromethane 99.4 Limits: 70-130%09/15/23 10:001000 ENM V37910 Surrogate: 1,2-Dichloroethane - d4 97.0 Limits: 70-130%09/15/23 10:001000 ENM V37910 Surrogate: Toluene-d8 101 Limits: 70-130%09/15/23 10:001000 ENM V37910 Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 14 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-8 94847 Matrix: 9/8/2023 11:50 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <1000 µg/L 1000Acetone 100 09/14/23 01:21 6200BMSA 1270 µg/L 50.0Benzene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Bromobenzene 100 09/14/23 01:21 6200BMSA <100 µg/L 100Bromochloromethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Bromodichloromethane 100 09/14/23 01:21 6200BMSA <500 µg/L 500Bromoform 100 09/14/23 01:21 6200BMSA <100 µg/L 100Bromomethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0n-Butylbenzene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0sec-Butyl benzene 100 09/14/23 01:21 6200BMSA <200 µg/L 200tert-Butyl benzene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Carbon Tetrachloride 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Chlorobenzene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Chlorodibromomethane 100 09/14/23 01:21 6200BMSA <100 µg/L 100Chloroethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Chloroform 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Chloromethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.02-Chlorotoluene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.04-Chlorotoluene 100 09/14/23 01:21 6200BMSA <200 µg/L 2001,2-Dibromo-3-Chloropropane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,2-Dibromoethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Dibromomethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,2-Dichlorobenzene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,3-Dichlorobenzene 100 09/14/23 01:21 6200BMSA Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 15 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-8 94847 Matrix: 9/8/2023 11:50 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <50.0 µg/L 50.01,4-Dichlorobenzene 100 09/14/23 01:21 6200BMSA <500 µg/L 500Dichlorodifluoromethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,1-Dichloroethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,2-Dichloroethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,1-Dichloroethene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0cis-1,2-Dichloroethene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0trans-1,2-Dichloroethene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,2-Dichloropropane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,3-Dichloropropane 100 09/14/23 01:21 6200BMSA <200 µg/L 2002,2-Dichloropropane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,1-Dichloropropene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0cis-1,3-Dichloropropene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0trans-1,3-Dichloropropene 100 09/14/23 01:21 6200BMSA <20000 µg/L 20000Ethanol 100 09/14/23 01:21 6200BMSA 1280 µg/L 50.0Ethylbenzene 100 09/14/23 01:21 6200BMSA <300 µg/L 300Hexachlorobutadiene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Di-Isopropyl Ether (DIPE)100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Isopropylbenzene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.04-Isopropyl toluene 100 09/14/23 01:21 6200BMSA <100 µg/L 1002-Hexanone 100 09/14/23 01:21 6200BMSA <500 µg/L 500Methyl Ethyl Ketone (MEK)100 09/14/23 01:21 6200BMSA <200 µg/L 200Methylene Chloride 100 09/14/23 01:21 6200BMSA <100 µg/L 100Methyl tert-butyl ether (MTBE)100 09/14/23 01:21 6200BMSA Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 16 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-8 94847 Matrix: 9/8/2023 11:50 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <100 µg/L 1004-Methyl-2-Pentanone 100 09/14/23 01:21 6200BMSA 457 µg/L 100Naphthalene 100 09/14/23 01:21 6200BMSA 97.6 µg/L 50.0n-Propylbenzene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Styrene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,1,1,2-Tetrachloroethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,1,2,2-Tetrachloroethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Tetrachloroethene 100 09/14/23 01:21 6200BMSA 3840 µg/L 50.0Toluene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,2,3-Trichlorobenzene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,2,4-Trichlorobenzene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,1,1-Trichloroethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,1,2-Trichloroethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Trichloroethene 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Trichlorofluoromethane 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.01,2,3-Trichloropropane 100 09/14/23 01:21 6200BMSA 1000 µg/L 50.01,2,4-Trimethylbenzene 100 09/14/23 01:21 6200BMSA 281 µg/L 50.01,3,5-Trimethylbenzene 100 09/14/23 01:21 6200BMSA <500 µg/L 500Vinyl Acetate 100 09/14/23 01:21 6200BMSA <50.0 µg/L 50.0Vinyl Chloride 100 09/14/23 01:21 6200BMSA 2340 µg/L 100m,p-Xylene 100 09/14/23 01:21 6200BMSA 2210 µg/L 50.0o-Xylene 100 09/14/23 01:21 6200BMSA Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 17 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-8 94847 Matrix: 9/8/2023 11:50 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF 4550 µg/L 50.0Xylene (Total)100 09/14/23 01:21 6200B Surrogate: 4-Bromofluorobenzene 95.4 Limits: 70-130%09/14/23 01:21100 MSA V37835 Surrogate: Dibromofluoromethane 101 Limits: 70-130%09/14/23 01:21100 MSA V37835 Surrogate: 1,2-Dichloroethane - d4 95.8 Limits: 70-130%09/14/23 01:21100 MSA V37835 Surrogate: Toluene-d8 100 Limits: 70-130%09/14/23 01:21100 MSA V37835 Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 18 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-10 94848 Matrix: 9/8/2023 12:00 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <100 µg/L 100Acetone 10 09/15/23 07:00 6200BENM 240 µg/L 5.00Benzene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Bromobenzene 10 09/15/23 07:00 6200BENM <10.0 µg/L 10.0Bromochloromethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Bromodichloromethane 10 09/15/23 07:00 6200BENM <50.0 µg/L 50.0Bromoform 10 09/15/23 07:00 6200BENM <10.0 µg/L 10.0Bromomethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00n-Butylbenzene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00sec-Butyl benzene 10 09/15/23 07:00 6200BENM <20.0 µg/L 20.0tert-Butyl benzene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Carbon Tetrachloride 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Chlorobenzene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Chlorodibromomethane 10 09/15/23 07:00 6200BENM <10.0 µg/L 10.0Chloroethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Chloroform 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Chloromethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.002-Chlorotoluene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.004-Chlorotoluene 10 09/15/23 07:00 6200BENM <20.0 µg/L 20.01,2-Dibromo-3-Chloropropane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,2-Dibromoethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Dibromomethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,2-Dichlorobenzene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,3-Dichlorobenzene 10 09/15/23 07:00 6200BENM Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 19 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-10 94848 Matrix: 9/8/2023 12:00 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <5.00 µg/L 5.001,4-Dichlorobenzene 10 09/15/23 07:00 6200BENM <50.0 µg/L 50.0Dichlorodifluoromethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,1-Dichloroethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,2-Dichloroethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,1-Dichloroethene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00cis-1,2-Dichloroethene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00trans-1,2-Dichloroethene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,2-Dichloropropane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,3-Dichloropropane 10 09/15/23 07:00 6200BENM <20.0 µg/L 20.02,2-Dichloropropane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,1-Dichloropropene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00cis-1,3-Dichloropropene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00trans-1,3-Dichloropropene 10 09/15/23 07:00 6200BENM <2000 µg/L 2000Ethanol 10 09/15/23 07:00 6200BENM 76.4 µg/L 5.00Ethylbenzene 10 09/15/23 07:00 6200BENM <30.0 µg/L 30.0Hexachlorobutadiene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Di-Isopropyl Ether (DIPE)10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Isopropylbenzene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.004-Isopropyl toluene 10 09/15/23 07:00 6200BENM <10.0 µg/L 10.02-Hexanone 10 09/15/23 07:00 6200BENM <50.0 µg/L 50.0Methyl Ethyl Ketone (MEK)10 09/15/23 07:00 6200BENM <20.0 µg/L 20.0Methylene Chloride 10 09/15/23 07:00 6200BENM <10.0 µg/L 10.0Methyl tert-butyl ether (MTBE)10 09/15/23 07:00 6200BENM Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 20 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-10 94848 Matrix: 9/8/2023 12:00 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF <10.0 µg/L 10.04-Methyl-2-Pentanone 10 09/15/23 07:00 6200BENM <10.0 µg/L 10.0Naphthalene 10 09/15/23 07:00 6200BENM 8.75 µg/L 5.00n-Propylbenzene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Styrene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,1,1,2-Tetrachloroethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,1,2,2-Tetrachloroethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Tetrachloroethene 10 09/15/23 07:00 6200BENM 93.7 µg/L 5.00Toluene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,2,3-Trichlorobenzene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,2,4-Trichlorobenzene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,1,1-Trichloroethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,1,2-Trichloroethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Trichloroethene 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Trichlorofluoromethane 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.001,2,3-Trichloropropane 10 09/15/23 07:00 6200BENM 52.7 µg/L 5.001,2,4-Trimethylbenzene 10 09/15/23 07:00 6200BENM 8.22 µg/L 5.001,3,5-Trimethylbenzene 10 09/15/23 07:00 6200BENM <50.0 µg/L 50.0Vinyl Acetate 10 09/15/23 07:00 6200BENM <5.00 µg/L 5.00Vinyl Chloride 10 09/15/23 07:00 6200BENM 112 µg/L 10.0m,p-Xylene 10 09/15/23 07:00 6200BENM 90.5 µg/L 5.00o-Xylene 10 09/15/23 07:00 6200BENM Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 21 of 36 , REPORT OF ANALYSISReport Number : Project Information : NC 27511 23-255-0053 01221 Withers & Ravenel 115 Mackenan Dr. BUILDING 117 Matt James Cary 23-307-BR Received : 09/12/2023 Former McCoy's Report Date : 09/18/2023 Sample ID : Lab No : Sampled:MW-10 94848 Matrix: 9/8/2023 12:00 Aqueous Test Results Units MQL By Analytical Method Date / Time Analyzed DF 203 µg/L 5.00Xylene (Total)10 09/15/23 07:00 6200B Surrogate: 4-Bromofluorobenzene 101 Limits: 70-130%09/15/23 07:0010 ENM V37910 Surrogate: Dibromofluoromethane 100 Limits: 70-130%09/15/23 07:0010 ENM V37910 Surrogate: 1,2-Dichloroethane - d4 96.0 Limits: 70-130%09/15/23 07:0010 ENM V37910 Surrogate: Toluene-d8 98.8 Limits: 70-130%09/15/23 07:0010 ENM V37910 Qualifiers/ Definitions Method Quantitation LimitMQLDilution FactorDF Page 22 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37835QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37833 Associated Lab Samples: 94845, 94846, 94847 LRB-V37833 Matrix: AQULab Reagent Blank Parameter AnalyzedMQLBlank ResultUnits % Recovery % Rec Limits 09/13/23 19:5910.0< 10.0µg/LAcetone 09/13/23 19:590.500< 0.500µg/LBenzene 09/13/23 19:590.500< 0.500µg/LBromobenzene 09/13/23 19:591.00< 1.00µg/LBromochloromethane 09/13/23 19:590.500< 0.500µg/LBromodichloromethane 09/13/23 19:595.00< 5.00µg/LBromoform 09/13/23 19:591.00< 1.00µg/LBromomethane 09/13/23 19:590.500< 0.500µg/Ln-Butylbenzene 09/13/23 19:590.500< 0.500µg/Lsec-Butyl benzene 09/13/23 19:592.00< 2.00µg/Ltert-Butyl benzene 09/13/23 19:590.500< 0.500µg/LCarbon Tetrachloride 09/13/23 19:590.500< 0.500µg/LChlorobenzene 09/13/23 19:590.500< 0.500µg/LChlorodibromomethane 09/13/23 19:591.00< 1.00µg/LChloroethane 09/13/23 19:590.500< 0.500µg/LChloroform 09/13/23 19:590.500< 0.500µg/LChloromethane 09/13/23 19:590.500< 0.500µg/L2-Chlorotoluene 09/13/23 19:590.500< 0.500µg/L4-Chlorotoluene 09/13/23 19:592.00< 2.00µg/L1,2-Dibromo-3-Chloropropane 09/13/23 19:590.500< 0.500µg/L1,2-Dibromoethane 09/13/23 19:590.500< 0.500µg/LDibromomethane 09/13/23 19:590.500< 0.500µg/L1,2-Dichlorobenzene 09/13/23 19:590.500< 0.500µg/L1,3-Dichlorobenzene 09/13/23 19:590.500< 0.500µg/L1,4-Dichlorobenzene 09/13/23 19:595.00< 5.00µg/LDichlorodifluoromethane 09/13/23 19:590.500< 0.500µg/L1,1-Dichloroethane 09/13/23 19:590.500< 0.500µg/L1,2-Dichloroethane Page 1 of 12Date:09/18/2023 07:37 AM Page 23 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37835QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37833 Associated Lab Samples: 94845, 94846, 94847 LRB-V37833 Matrix: AQULab Reagent Blank Parameter AnalyzedMQLBlank ResultUnits % Recovery % Rec Limits 09/13/23 19:590.500< 0.500µg/L1,1-Dichloroethene 09/13/23 19:590.500< 0.500µg/Lcis-1,2-Dichloroethene 09/13/23 19:590.500< 0.500µg/Ltrans-1,2-Dichloroethene 09/13/23 19:590.500< 0.500µg/L1,2-Dichloropropane 09/13/23 19:590.500< 0.500µg/L1,3-Dichloropropane 09/13/23 19:592.00< 2.00µg/L2,2-Dichloropropane 09/13/23 19:590.500< 0.500µg/L1,1-Dichloropropene 09/13/23 19:590.500< 0.500µg/Lcis-1,3-Dichloropropene 09/13/23 19:590.500< 0.500µg/Ltrans-1,3-Dichloropropene 09/13/23 19:59200< 200µg/LEthanol 09/13/23 19:590.500< 0.500µg/LEthylbenzene 09/13/23 19:593.00< 3.00µg/LHexachlorobutadiene 09/13/23 19:590.500< 0.500µg/LDi-Isopropyl Ether (DIPE) 09/13/23 19:590.500< 0.500µg/LIsopropylbenzene 09/13/23 19:590.500< 0.500µg/L4-Isopropyl toluene 09/13/23 19:591.00< 1.00µg/L2-Hexanone 09/13/23 19:595.00< 5.00µg/LMethyl Ethyl Ketone (MEK) 09/13/23 19:592.00< 2.00µg/LMethylene Chloride 09/13/23 19:591.00< 1.00µg/LMethyl tert-butyl ether (MTBE) 09/13/23 19:591.00< 1.00µg/L4-Methyl-2-Pentanone 09/13/23 19:591.00< 1.00µg/LNaphthalene 09/13/23 19:590.500< 0.500µg/Ln-Propylbenzene 09/13/23 19:590.500< 0.500µg/LStyrene 09/13/23 19:590.500< 0.500µg/L1,1,1,2-Tetrachloroethane 09/13/23 19:590.500< 0.500µg/L1,1,2,2-Tetrachloroethane 09/13/23 19:590.500< 0.500µg/LTetrachloroethene 09/13/23 19:590.500< 0.500µg/LToluene Page 2 of 12Date:09/18/2023 07:37 AM Page 24 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37835QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37833 Associated Lab Samples: 94845, 94846, 94847 LRB-V37833 Matrix: AQULab Reagent Blank Parameter AnalyzedMQLBlank ResultUnits % Recovery % Rec Limits 09/13/23 19:590.500< 0.500µg/L1,2,3-Trichlorobenzene 09/13/23 19:590.500< 0.500µg/L1,2,4-Trichlorobenzene 09/13/23 19:590.500< 0.500µg/L1,1,1-Trichloroethane 09/13/23 19:590.500< 0.500µg/L1,1,2-Trichloroethane 09/13/23 19:590.500< 0.500µg/LTrichloroethene 09/13/23 19:590.500< 0.500µg/LTrichlorofluoromethane 09/13/23 19:590.500< 0.500µg/L1,2,3-Trichloropropane 09/13/23 19:590.500< 0.500µg/L1,2,4-Trimethylbenzene 09/13/23 19:590.500< 0.500µg/L1,3,5-Trimethylbenzene 09/13/23 19:595.00< 5.00µg/LVinyl Acetate 09/13/23 19:590.500< 0.500µg/LVinyl Chloride 09/13/23 19:591.00< 1.00µg/Lm,p-Xylene 09/13/23 19:590.500< 0.500µg/Lo-Xylene 09/13/23 19:594-Bromofluorobenzene (S)101 70-130 09/13/23 19:59Dibromofluoromethane (S)102 70-130 09/13/23 19:591,2-Dichloroethane - d4 (S)99.0 70-130 09/13/23 19:59Toluene-d8 (S)100 70-130 LCS-V37833 LCSD-V37833Laboratory Control Sample & LCSD LCSD ResultParameter Max RPD LCSD % Rec LCS %Rec LCS Result Spike Conc.Units % Rec Limits RPD 36.2 90.596.738.740.0µg/LAcetone 40-160 6.6 20.0 22.1 11110821.520.0µg/LBenzene 70-130 2.7 20.0 21.5 10810721.320.0µg/LBromobenzene 70-130 0.9 20.0 21.9 11010721.320.0µg/LBromochloromethane 70-130 2.7 20.0 21.7 10910420.820.0µg/LBromodichloromethane 70-130 4.2 20.0 Page 3 of 12Date:09/18/2023 07:37 AM Page 25 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37835QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37833 LCS-V37833 LCSD-V37833Laboratory Control Sample & LCSD LCSD ResultParameter Max RPD LCSD % Rec LCS %Rec LCS Result Spike Conc.Units % Rec Limits RPD 21.1 10610521.020.0µg/LBromoform 70-130 0.4 20.0 22.6 11310621.120.0µg/LBromomethane 60-140 6.8 20.0 22.1 11110821.620.0µg/Ln-Butylbenzene 70-130 2.2 20.0 21.2 10610521.020.0µg/Lsec-Butyl benzene 70-130 0.9 20.0 21.4 10710621.120.0µg/Ltert-Butyl benzene 70-130 1.4 20.0 20.4 10210120.120.0µg/LCarbon Tetrachloride 70-130 1.4 20.0 21.6 10810721.320.0µg/LChlorobenzene 70-130 1.3 20.0 21.9 11010821.620.0µg/LChlorodibromomethane 70-130 1.3 20.0 19.4 97.093.518.720.0µg/LChloroethane 60-140 3.6 20.0 21.7 10910621.220.0µg/LChloroform 70-130 2.3 20.0 20.6 10310220.420.0µg/LChloromethane 60-140 0.9 20.0 21.6 10810821.520.0µg/L2-Chlorotoluene 70-130 0.4 20.0 21.7 10910821.520.0µg/L4-Chlorotoluene 70-130 0.9 20.0 23.8 11910420.820.0µg/L1,2-Dibromo-3-Chloropropane 70-130 13.4 20.0 22.2 11111021.920.0µg/L1,2-Dibromoethane 70-130 1.3 20.0 21.6 10810320.620.0µg/LDibromomethane 70-130 4.7 20.0 22.3 11210721.420.0µg/L1,2-Dichlorobenzene 70-130 4.1 20.0 22.0 11010721.320.0µg/L1,3-Dichlorobenzene 70-130 3.2 20.0 21.7 10910520.920.0µg/L1,4-Dichlorobenzene 70-130 3.7 20.0 20.3 10299.519.920.0µg/LDichlorodifluoromethane 60-140 1.9 20.0 22.3 11210921.720.0µg/L1,1-Dichloroethane 70-130 2.7 20.0 21.0 10510520.920.0µg/L1,2-Dichloroethane 70-130 0.4 20.0 22.9 11511222.420.0µg/L1,1-Dichloroethene 70-130 2.2 20.0 22.2 11110921.820.0µg/Lcis-1,2-Dichloroethene 70-130 1.8 20.0 22.0 11011021.920.0µg/Ltrans-1,2-Dichloroethene 70-130 0.4 20.0 21.9 11010621.120.0µg/L1,2-Dichloropropane 70-130 3.7 20.0 Page 4 of 12Date:09/18/2023 07:37 AM Page 26 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37835QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37833 LCS-V37833 LCSD-V37833Laboratory Control Sample & LCSD LCSD ResultParameter Max RPD LCSD % Rec LCS %Rec LCS Result Spike Conc.Units % Rec Limits RPD 21.7 10910721.320.0µg/L1,3-Dichloropropane 70-130 1.8 20.0 20.9 10510821.520.0µg/L2,2-Dichloropropane 70-130 2.8 20.0 23.4 11711422.820.0µg/L1,1-Dichloropropene 70-130 2.5 20.0 21.2 10610420.720.0µg/Lcis-1,3-Dichloropropene 70-130 2.3 20.0 21.7 10910521.020.0µg/Ltrans-1,3-Dichloropropene 70-130 3.2 20.0 530 106102509500µg/LEthanol 60-140 4.0 20.0 21.3 10710621.120.0µg/LEthylbenzene 70-130 0.9 20.0 20.5 10310621.220.0µg/LHexachlorobutadiene 70-130 3.3 20.0 21.7 10910621.220.0µg/LDi-Isopropyl Ether (DIPE)70-130 2.3 20.0 22.1 11110921.720.0µg/LIsopropylbenzene 70-130 1.8 20.0 22.3 11211122.120.0µg/L4-Isopropyl toluene 70-130 0.9 20.0 20.7 10410621.220.0µg/L2-Hexanone 60-140 2.3 20.0 17.2 86.086.517.320.0µg/LMethyl Ethyl Ketone (MEK)60-140 0.5 20.0 22.2 11110921.820.0µg/LMethylene Chloride 70-130 1.8 20.0 22.2 11110721.420.0µg/LMethyl tert-butyl ether (MTBE)70-130 3.6 20.0 22.3 11210621.120.0µg/L4-Methyl-2-Pentanone 60-140 5.5 20.0 22.6 11311422.820.0µg/LNaphthalene 70-130 0.8 20.0 21.7 10910721.420.0µg/Ln-Propylbenzene 70-130 1.3 20.0 22.1 11111022.020.0µg/LStyrene 70-130 0.4 20.0 21.4 10710821.620.0µg/L1,1,1,2-Tetrachloroethane 70-130 0.9 20.0 21.9 11010520.920.0µg/L1,1,2,2-Tetrachloroethane 70-130 4.6 20.0 21.7 10910821.520.0µg/LTetrachloroethene 70-130 0.9 20.0 21.7 10910721.320.0µg/LToluene 70-130 1.8 20.0 22.8 11411222.420.0µg/L1,2,3-Trichlorobenzene 70-130 1.7 20.0 22.9 11512224.320.0µg/L1,2,4-Trichlorobenzene 70-130 5.9 20.0 22.1 11110721.420.0µg/L1,1,1-Trichloroethane 70-130 3.2 20.0 Page 5 of 12Date:09/18/2023 07:37 AM Page 27 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37835QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37833 LCS-V37833 LCSD-V37833Laboratory Control Sample & LCSD LCSD ResultParameter Max RPD LCSD % Rec LCS %Rec LCS Result Spike Conc.Units % Rec Limits RPD 21.7 10910721.420.0µg/L1,1,2-Trichloroethane 70-130 1.3 20.0 21.7 10911021.920.0µg/LTrichloroethene 70-130 0.9 20.0 21.4 10710621.220.0µg/LTrichlorofluoromethane 60-140 0.9 20.0 21.1 10610721.420.0µg/L1,2,3-Trichloropropane 70-130 1.4 20.0 22.1 11110921.720.0µg/L1,2,4-Trimethylbenzene 70-130 1.8 20.0 21.8 10910921.720.0µg/L1,3,5-Trimethylbenzene 70-130 0.4 20.0 25.6 12898.019.620.0µg/LVinyl Acetate 60-140 26.5*20.0 22.1 11110921.820.0µg/LVinyl Chloride 60-140 1.3 20.0 45.6 11411445.740.0µg/Lm,p-Xylene 70-130 0.2 20.0 21.6 10810721.320.0µg/Lo-Xylene 70-130 1.3 20.0 99.298.44-Bromofluorobenzene (S)70-130 101101Dibromofluoromethane (S)70-130 1031011,2-Dichloroethane - d4 (S)70-130 99.4101Toluene-d8 (S)70-130 Page 6 of 12* QC Fail Date:09/18/2023 07:37 AM Page 28 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37910QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37909 Associated Lab Samples: 94845, 94846, 94848 LRB-V37909 Matrix: AQULab Reagent Blank Parameter AnalyzedMQLBlank ResultUnits % Recovery % Rec Limits 09/15/23 04:5110.0< 10.0µg/LAcetone 09/15/23 04:510.500< 0.500µg/LBenzene 09/15/23 04:510.500< 0.500µg/LBromobenzene 09/15/23 04:511.00< 1.00µg/LBromochloromethane 09/15/23 04:510.500< 0.500µg/LBromodichloromethane 09/15/23 04:515.00< 5.00µg/LBromoform 09/15/23 04:511.00< 1.00µg/LBromomethane 09/15/23 04:510.500< 0.500µg/Ln-Butylbenzene 09/15/23 04:510.500< 0.500µg/Lsec-Butyl benzene 09/15/23 04:512.00< 2.00µg/Ltert-Butyl benzene 09/15/23 04:510.500< 0.500µg/LCarbon Tetrachloride 09/15/23 04:510.500< 0.500µg/LChlorobenzene 09/15/23 04:510.500< 0.500µg/LChlorodibromomethane 09/15/23 04:511.00< 1.00µg/LChloroethane 09/15/23 04:510.500< 0.500µg/LChloroform 09/15/23 04:510.500< 0.500µg/LChloromethane 09/15/23 04:510.500< 0.500µg/L2-Chlorotoluene 09/15/23 04:510.500< 0.500µg/L4-Chlorotoluene 09/15/23 04:512.00< 2.00µg/L1,2-Dibromo-3-Chloropropane 09/15/23 04:510.500< 0.500µg/L1,2-Dibromoethane 09/15/23 04:510.500< 0.500µg/LDibromomethane 09/15/23 04:510.500< 0.500µg/L1,2-Dichlorobenzene 09/15/23 04:510.500< 0.500µg/L1,3-Dichlorobenzene 09/15/23 04:510.500< 0.500µg/L1,4-Dichlorobenzene 09/15/23 04:515.00< 5.00µg/LDichlorodifluoromethane 09/15/23 04:510.500< 0.500µg/L1,1-Dichloroethane 09/15/23 04:510.500< 0.500µg/L1,2-Dichloroethane Page 7 of 12Date:09/18/2023 07:37 AM Page 29 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37910QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37909 Associated Lab Samples: 94845, 94846, 94848 LRB-V37909 Matrix: AQULab Reagent Blank Parameter AnalyzedMQLBlank ResultUnits % Recovery % Rec Limits 09/15/23 04:510.500< 0.500µg/L1,1-Dichloroethene 09/15/23 04:510.500< 0.500µg/Lcis-1,2-Dichloroethene 09/15/23 04:510.500< 0.500µg/Ltrans-1,2-Dichloroethene 09/15/23 04:510.500< 0.500µg/L1,2-Dichloropropane 09/15/23 04:510.500< 0.500µg/L1,3-Dichloropropane 09/15/23 04:512.00< 2.00µg/L2,2-Dichloropropane 09/15/23 04:510.500< 0.500µg/L1,1-Dichloropropene 09/15/23 04:510.500< 0.500µg/Lcis-1,3-Dichloropropene 09/15/23 04:510.500< 0.500µg/Ltrans-1,3-Dichloropropene 09/15/23 04:51200< 200µg/LEthanol 09/15/23 04:510.500< 0.500µg/LEthylbenzene 09/15/23 04:513.00< 3.00µg/LHexachlorobutadiene 09/15/23 04:510.500< 0.500µg/LDi-Isopropyl Ether (DIPE) 09/15/23 04:510.500< 0.500µg/LIsopropylbenzene 09/15/23 04:510.500< 0.500µg/L4-Isopropyl toluene 09/15/23 04:511.00< 1.00µg/L2-Hexanone 09/15/23 04:515.00< 5.00µg/LMethyl Ethyl Ketone (MEK) 09/15/23 04:512.00< 2.00µg/LMethylene Chloride 09/15/23 04:511.00< 1.00µg/LMethyl tert-butyl ether (MTBE) 09/15/23 04:511.00< 1.00µg/L4-Methyl-2-Pentanone 09/15/23 04:511.00< 1.00µg/LNaphthalene 09/15/23 04:510.500< 0.500µg/Ln-Propylbenzene 09/15/23 04:510.500< 0.500µg/LStyrene 09/15/23 04:510.500< 0.500µg/L1,1,1,2-Tetrachloroethane 09/15/23 04:510.500< 0.500µg/L1,1,2,2-Tetrachloroethane 09/15/23 04:510.500< 0.500µg/LTetrachloroethene 09/15/23 04:510.500< 0.500µg/LToluene Page 8 of 12Date:09/18/2023 07:37 AM Page 30 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37910QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37909 Associated Lab Samples: 94845, 94846, 94848 LRB-V37909 Matrix: AQULab Reagent Blank Parameter AnalyzedMQLBlank ResultUnits % Recovery % Rec Limits 09/15/23 04:510.500< 0.500µg/L1,2,3-Trichlorobenzene 09/15/23 04:510.500< 0.500µg/L1,2,4-Trichlorobenzene 09/15/23 04:510.500< 0.500µg/L1,1,1-Trichloroethane 09/15/23 04:510.500< 0.500µg/L1,1,2-Trichloroethane 09/15/23 04:510.500< 0.500µg/LTrichloroethene 09/15/23 04:510.500< 0.500µg/LTrichlorofluoromethane 09/15/23 04:510.500< 0.500µg/L1,2,3-Trichloropropane 09/15/23 04:510.500< 0.500µg/L1,2,4-Trimethylbenzene 09/15/23 04:510.500< 0.500µg/L1,3,5-Trimethylbenzene 09/15/23 04:515.00< 5.00µg/LVinyl Acetate 09/15/23 04:510.500< 0.500µg/LVinyl Chloride 09/15/23 04:511.00< 1.00µg/Lm,p-Xylene 09/15/23 04:510.500< 0.500µg/Lo-Xylene 09/15/23 04:514-Bromofluorobenzene (S)99.4 70-130 09/15/23 04:51Dibromofluoromethane (S)101 70-130 09/15/23 04:511,2-Dichloroethane - d4 (S)97.6 70-130 09/15/23 04:51Toluene-d8 (S)100 70-130 LCS-V37909 LCSD-V37909Laboratory Control Sample & LCSD LCSD ResultParameter Max RPD LCSD % Rec LCS %Rec LCS Result Spike Conc.Units % Rec Limits RPD 41.8 10510240.740.0µg/LAcetone 40-160 2.6 20.0 22.2 11111222.420.0µg/LBenzene 70-130 0.8 20.0 23.9 12012324.620.0µg/LBromobenzene 70-130 2.8 20.0 23.5 11811723.420.0µg/LBromochloromethane 70-130 0.4 20.0 22.6 11311222.420.0µg/LBromodichloromethane 70-130 0.8 20.0 Page 9 of 12Date:09/18/2023 07:37 AM Page 31 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37910QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37909 LCS-V37909 LCSD-V37909Laboratory Control Sample & LCSD LCSD ResultParameter Max RPD LCSD % Rec LCS %Rec LCS Result Spike Conc.Units % Rec Limits RPD 18.9 94.510120.220.0µg/LBromoform 70-130 6.6 20.0 23.8 11912725.420.0µg/LBromomethane 60-140 6.5 20.0 23.8 11912124.220.0µg/Ln-Butylbenzene 70-130 1.6 20.0 23.1 11612224.420.0µg/Lsec-Butyl benzene 70-130 5.4 20.0 23.4 11712324.520.0µg/Ltert-Butyl benzene 70-130 4.5 20.0 23.0 11511422.720.0µg/LCarbon Tetrachloride 70-130 1.3 20.0 23.7 11912124.120.0µg/LChlorobenzene 70-130 1.6 20.0 22.9 11511422.720.0µg/LChlorodibromomethane 70-130 0.8 20.0 21.5 10812324.520.0µg/LChloroethane 60-140 13.0 20.0 23.0 11511422.720.0µg/LChloroform 70-130 1.3 20.0 19.9 99.511222.420.0µg/LChloromethane 60-140 11.8 20.0 23.4 11712124.220.0µg/L2-Chlorotoluene 70-130 3.3 20.0 23.1 11612024.020.0µg/L4-Chlorotoluene 70-130 3.8 20.0 21.5 10810721.420.0µg/L1,2-Dibromo-3-Chloropropane 70-130 0.4 20.0 23.4 11711923.720.0µg/L1,2-Dibromoethane 70-130 1.2 20.0 22.6 11311522.920.0µg/LDibromomethane 70-130 1.3 20.0 23.0 11512024.020.0µg/L1,2-Dichlorobenzene 70-130 4.2 20.0 23.8 11912224.320.0µg/L1,3-Dichlorobenzene 70-130 2.0 20.0 23.6 11811923.820.0µg/L1,4-Dichlorobenzene 70-130 0.8 20.0 22.1 11112424.820.0µg/LDichlorodifluoromethane 60-140 11.5 20.0 22.7 11411923.820.0µg/L1,1-Dichloroethane 70-130 4.7 20.0 20.7 10410320.520.0µg/L1,2-Dichloroethane 70-130 0.9 20.0 23.2 11612324.620.0µg/L1,1-Dichloroethene 70-130 5.8 20.0 22.7 11411723.320.0µg/Lcis-1,2-Dichloroethene 70-130 2.6 20.0 23.2 11612024.020.0µg/Ltrans-1,2-Dichloroethene 70-130 3.3 20.0 22.3 11210921.820.0µg/L1,2-Dichloropropane 70-130 2.2 20.0 Page 10 of 12Date:09/18/2023 07:37 AM Page 32 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37910QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37909 LCS-V37909 LCSD-V37909Laboratory Control Sample & LCSD LCSD ResultParameter Max RPD LCSD % Rec LCS %Rec LCS Result Spike Conc.Units % Rec Limits RPD 21.9 11010921.820.0µg/L1,3-Dichloropropane 70-130 0.4 20.0 18.8 94.010220.320.0µg/L2,2-Dichloropropane 70-130 7.6 20.0 23.3 11711723.320.0µg/L1,1-Dichloropropene 70-130 0.0 20.0 21.3 10711021.920.0µg/Lcis-1,3-Dichloropropene 70-130 2.7 20.0 20.8 10410420.720.0µg/Ltrans-1,3-Dichloropropene 70-130 0.4 20.0 383 76.669.0345500µg/LEthanol 60-140 10.4 20.0 22.7 11411523.020.0µg/LEthylbenzene 70-130 1.3 20.0 23.7 11911923.820.0µg/LHexachlorobutadiene 70-130 0.4 20.0 21.6 10810921.820.0µg/LDi-Isopropyl Ether (DIPE)70-130 0.9 20.0 23.9 12012625.120.0µg/LIsopropylbenzene 70-130 4.8 20.0 23.9 12012525.020.0µg/L4-Isopropyl toluene 70-130 4.4 20.0 19.6 98.096.019.220.0µg/L2-Hexanone 60-140 2.0 20.0 16.5 82.578.515.720.0µg/LMethyl Ethyl Ketone (MEK)60-140 4.9 20.0 20.7 10410420.720.0µg/LMethylene Chloride 70-130 0.0 20.0 21.9 11010921.720.0µg/LMethyl tert-butyl ether (MTBE)70-130 0.9 20.0 19.9 99.599.019.820.0µg/L4-Methyl-2-Pentanone 60-140 0.5 20.0 20.9 10510921.820.0µg/LNaphthalene 70-130 4.2 20.0 23.4 11712024.020.0µg/Ln-Propylbenzene 70-130 2.5 20.0 23.1 11611823.520.0µg/LStyrene 70-130 1.7 20.0 24.7 12412324.520.0µg/L1,1,1,2-Tetrachloroethane 70-130 0.8 20.0 21.7 10911222.420.0µg/L1,1,2,2-Tetrachloroethane 70-130 3.1 20.0 22.9 11511823.620.0µg/LTetrachloroethene 70-130 3.0 20.0 22.5 11311222.420.0µg/LToluene 70-130 0.4 20.0 22.7 11411923.720.0µg/L1,2,3-Trichlorobenzene 70-130 4.3 20.0 19.3 96.510220.420.0µg/L1,2,4-Trichlorobenzene 70-130 5.5 20.0 22.8 11411422.720.0µg/L1,1,1-Trichloroethane 70-130 0.4 20.0 Page 11 of 12Date:09/18/2023 07:37 AM Page 33 of 36 Quality Control Data 23-255-0053Report No: Project Description: Client ID:Withers & Ravenel Former McCoy's QC Prep Batch Method: Volatile Organic Compounds - GC/MS 6200B V37910QC Analytical Batch(es): Analysis Method: Analysis Description: 6200 PT QC Prep:V37909 LCS-V37909 LCSD-V37909Laboratory Control Sample & LCSD LCSD ResultParameter Max RPD LCSD % Rec LCS %Rec LCS Result Spike Conc.Units % Rec Limits RPD 23.1 11611522.920.0µg/L1,1,2-Trichloroethane 70-130 0.8 20.0 24.0 12012124.120.0µg/LTrichloroethene 70-130 0.4 20.0 22.2 11112424.720.0µg/LTrichlorofluoromethane 60-140 10.6 20.0 22.6 11311723.420.0µg/L1,2,3-Trichloropropane 70-130 3.4 20.0 24.3 12212324.620.0µg/L1,2,4-Trimethylbenzene 70-130 1.2 20.0 24.1 12112625.120.0µg/L1,3,5-Trimethylbenzene 70-130 4.0 20.0 17.5 87.599.519.920.0µg/LVinyl Acetate 60-140 12.8 20.0 23.7 11913226.420.0µg/LVinyl Chloride 60-140 10.7 20.0 47.4 11912148.540.0µg/Lm,p-Xylene 70-130 2.2 20.0 23.0 11511823.520.0µg/Lo-Xylene 70-130 2.1 20.0 95.297.04-Bromofluorobenzene (S)70-130 10196.4Dibromofluoromethane (S)70-130 97.497.81,2-Dichloroethane - d4 (S)70-130 101100Toluene-d8 (S)70-130 Page 12 of 12Date:09/18/2023 07:37 AM Page 34 of 36 Fed Ex UPS US Postal Client Lab Courier Other : Shipment Receipt Form Customer Number: Customer Name: Report Number:23-255-0053 Withers & Ravenel 01221 Shipping Method Shipping container/cooler uncompromised? Thermometer ID:IRT-15 1.1C Chain of Custody (COC) present?Yes No Yes No Not Present Yes No Not Present Yes No COC agrees with sample label(s)? Yes No COC properly completed Samples in proper containers? Sample containers intact? Sufficient sample volume for indicated test(s)? All samples received within holding time? Cooler temperature in compliance? Yes No Yes No Yes No Yes No Yes No Yes NoCooler/Samples arrived at the laboratory on ice. Samples were considered acceptable as cooling process had begun. Yes No Yes No N/A Yes No N/A Yes No N/ASoil VOA method 5035 – compliance criteria met Water - Sample containers properly preserved Water - VOA vials free of headspace Yes No N/A Trip Blanks received with VOAs Low concentration EnCore samplers (48 hr) High concentration pre-weighed (methanol -14 d) Low conc pre-weighed vials (Sod Bis -14 d) High concentration container (48 hr) Custody seals intact on shipping container/cooler? Custody seals intact on sample bottles? Number of coolers/boxes received Yes No 1 Signature:Caitlyn Cummins Date & Time:09/12/2023 17:47:55 Special precautions or instructions included? Comments: Page 35 of 36 Page 36 of 36