Loading...
HomeMy WebLinkAboutNCD980602163_19970401_Warren County PCB Landfill_SERB C_Results of Personnel Monitoring-OCRRecycled Paper S&ME April 1, 1997 Mr. Michael Kelly, Deputy Director Division of Waste Management North Carolina Department of Environment, Health and Natural Resources P.O. Box 27687 Raleigh, North Carolina 27611-7687 Reference: Results of Personnel Monitoring Warren County PCB Landfill Warren County, North Carolina S&ME Project 1054-97-670 Dear Mr. Kelly: Please find attached the results of the air monitoring performed for two of S&ME's drilling personnel while intrusive activities were performed at the landfill on February 18 and 19, 1997. Monitoring was performed using a low-flow pump with a calibrated flow rate of 102 cubic centimeters per minute. Pumped ambient air was passed through glass fiber filter/ florsil sampling media. On February 18, 1997, Mr. Michael Martin and Mr. Ray Norwood were monitored for a total time of 378 minutes (i.e. 39.5 liters, Samples 1 and 2 on the attached laboratory report). The same employees were monitored on February 19, 1997. Mr. Martin was monitored for 169 minutes and Mr. Norwood was monitored for 173 minutes (Samples 3 at 17.2 liters and 4, at 17.6 liters respectively). The analytical report indicates that no particulate PCBs were detected on the four sampling media at the detection level of 0.2 µg. No volatile PCBs were detected. This correlates to less than 0.005 mg/M3 of PCBs for February 18 and less than 0.011 and 0.012 mg/M3 PCBs on February 19, 1996. S&ME, Inc. 3100 Spring Forest Road, Raleigh, North Carolina 27616, (919) 872-2660, Fax (919) 790-9827 Mailing address: P.O. 13ox 58069, Raleigh, North Carolina 27658-8069 Mr. Michael Kelly April 1, 1997 Page 2 The personnel monitoring confirms that no exposures were measured. Please call us at (919) 872-2660 if you have any questions regarding the monitoring, the site activities completed while monitoring was in progress, or if we can be of further service. Sincerely, S&ME, INC. tu~/~ Walter J. Beckwith, P.G. Senior Project Geologist cc: Mr. Dan Caton 97-670\pmon_rpt.ltr ~-·= = .=. .,,,,-_------ - -----►-~ ---=- ..;...~------------~ Analytics Di:i:~-==-= -_ Laboratory Corporation of America™ Holdings PO Box 25249 Richmond. Virginia 23260 Telephone: 800-888-8061 BOB BRYANT S & M E 3100 SPRING FOREST RD RALEIGH, NC 27658 Date Received: 02/25/97 Group No. Account No. Report Date: Final Report Sample Type: 4 -Glass fiber filter/Florsil Project: 1054~97-670 PO Number: Analytical Method -continued PCB-Total Notes NIOSH METHOD 5503 8971 B056026 32419615 03/04/97 Attached are the results we obtained on the analysis of your samples. Any Chains-of-Custody associated with this sample group are also enclosed. Air concentrations are calculated as a convenience to the client and the overall accuracy of this result depends on both the accuracy of the air volume and the amount found by analysis. Theoretical Air Volumes for passive monitors are calculated using the sampling time submitted and the manufacturer's listed sampling rate for each compound. We appreciate your confidence in allowing Analytics to be your testing laboratory. Any questions regarding this report can be addressed by calling our client services department (800-888-8061). Page 2 Laboratory Corporation of America™ Holdings PO Box 25249 Richmond. Virginia 23260 Telephone: 800-888-8061 BOB BRYANT S & M E 3100 SPRING FOREST RD RALEIGH, NC 27658 Date Received: 02/25/97 Group No. Account No. Report Date: Final Report Sample Type: 1 Project: 4 -Glass fiber filter/Florsil 1054-97-670 PO Number: 8971 B056026 32419615 03/04/97 Analytical Results Lab Client ID Parameter Volume Amount Concentration -001 1 -002 2 -003 3 -004 4 Sample Date: 02/18/97 PCB-Filter PCB-Front PCB-Rear PCB-Total Sample Date: 02/18/97 PCB-Filter PCB-Front PCB-Rear PCB-Total Sample Date: 02/19/97 PCB-Filter PCB-Front PCB-Rear PCB-Total Sample Date: 02/19/97 PCB-Filter PCB-Front PCB-Rear PCB-Total 38.5 38.5 38.5 38.5 17 .2 17.2 17.6 17.6 < .2 ug ND ND < .2 ug < 0.005 mg/M3 < .2 ug ND ND < .2 ug < 0.005 mg/M3 < . 2 ug ND ND < .2 ug < 0.012 mg/M3 < .2 ug ND ND < .2 ug < 0.011 mg/M3 Abbreviations: ug = micrograms, mg= milligrams, mg/M3 = milligrams per cubic meter of air, g = grams, ug/M3 = micrograms per cubic meter of air, L = liters, w/w = percent weight basis, all Volumes given in liters, ppm= parts per million, ppb = parts per billion, Areas given in square feet; ND= Not Detected. Summary of Analytical Methods Parameter Analytical Method PCB-Filter NIOSH METHOD 5503 Page 1 f-C a, "' <'l a, riJ OJ OJ 6 !,l, (/) 0 <'l OJ ,i, OJ " OJ u z i D ti z J II :J Ill (/) :i II D u. (/) CJl w z iii :J Ill >-w _, CJl ~ □ .. LABORATORY TEST REQUEST ACCOUNT NAME AND ADDRESS: S & M E 3100 SPRING FOREST RD RALEIGH, NC 27658 Phone: 919-872-2660 Fax: 1-919-790-9827 ACCOUNT NUMBER 32419615 85 VAY DATE SHIPPED #OF SAMPLES SAMPLE TYPE/MEDIA 7 PURCHASE ORDER ?9 7 PRIORITY ANALYSIS □ 1DAY CONTACT □ □ 2DAY ~STANDARD •"'f • .,...,_.,'°"o EXTRA CHARGE FOR LABORATORY USE ONLY SAMPLE # OR SAMPLE AREA 3 lf SAMPLES HAVE BEEN SEALED FOR TRANSPORT AND DELIVERED TO LABORATORY VIA: /4· ... borki~ 77 q47 D1v SAMPLE DATE 1 I 'CARRIER IF '·LABCORP COURIER" SIGN HERE DATE/TIME CONDITiON OF SAMPLE 2 3 SIGNATURE (LAB) 4 SIGNATURE (LAB) ~ = -=--===----~-=-=:;-~-;: ~ Analytics Division - 8040 VILLA PARK DRIVE SUITE 250 RICHMOND, VIRGINIA 23228 (804) 264-7100 TOLL FREE (800) 888-8061 PROJECT NAME OR NUMBER TELEPHONE NUMBER DATE SAMPLE RETURN? □ EXTRA CHARGE SAMPLES RELEASED BY: SIGNATURE (SAMPLE RECEIVING) SIGNATURE (SAMPLE ADMINISTRATION) SIGNATURE (LAB) SIGNATURE (LAB)