Loading...
HomeMy WebLinkAbout4101_Guilford_CityHighPoint_Riverdale_MSWLF_Seaboard_Sept23LFG_FID1819484_20231024DocuSign Envelope ID: 64E5DF4C-3B3C-4CC8-92BC-B8834D2217C6 DENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Smith Gardner, Inc. Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Seth C. Rickerts, PG E-mail: seth@smithgardnerinc.com Phone: (919) 828 - 0577 x135 NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) High Point Riverdale Closed MSW Riverdale Drive, High Point, NC 41-01 .0500 September 28, 2023 Landfill Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑X Detection Monitoring ❑ Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Seth C. Rickerts, PG Project Geologist (919) 828 - 0577 x135 Facility Representative Name (Print) Title 10/23/2023 [ Si5:_ i C_ 2.-v e, Signature 3111-178EA0E6 Date 14 N. Boylan Ave, Raleigh, NC 27603 Facility Representative Address F-1370 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 (Area Code) Telephone Number Affix NC Licensed/ Professional Geologist Seal a` yi. rr r 275$ 10/ 3/2023 A� Al 's �OG� �+rr...C• RK�. DocuSign Envelope ID: 64E5DF4C-3B3C-4CC8-92BC-B8834D2217C6 This page intentionally left blank. DocuSign Envelope ID: 64E5DF4C-3B3C-4CC8-92BC-B8834D2217C6 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: City of High Point Closed Riverdale Landfill Date of Sampling: 09/28/2023 Name and Position of Sample Collector: Permit Number: 41-01 NC Landfill Rule (.0500 or .1600): .0500 Kyle M. Bonnett - Environmental Technician Type and Serial Number of Gas Meter: GEM 5000, G506472 Date and Time of Field Calibration: 09/28/2023, 1155 Calibration Date of Gas Meter: 01 /2023 Type of Field Calibration Gas (15115 or 35/50): 35/50 Expiration Date of Field Calibration Gas Canister: 10/2023 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 70 F Barometric Pressure: 29.33 in Hg General Weather Conditions: Partly Cloudy Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 Location or LFG Well ID Sample Tube Purge Time Time Pumped (s) Initial gZEL Stabilized °,,ZEL df4CH4 by Vohlme %02 %CO2 Notes H2 S ppm 1-1 >60s 1254 >60s 0 0 0.0 14.1 7.0 1 LFG 3 - - - - - - - LFG 4 >60s 1301 >60s 0 0 0.0 17.6 2.5 2 LFG 5 >60s 1303 >60s 0 0 0.0 16.5 3.3 2 LFG 6 >60s 1306 >60s 50 50 2.5 10.0 12.5 2 LFG 7 >60s 1329 >60s 848 848 42.4 0.6 26.4 2 7-1 >60s 1327 >60s 640 640 32.0 5.2 26.6 2 7-2 >60s 1324 >60s 0 0 0.0 17.6 2.5 1 7-3 >60s 1323 >60s 262 262 13.1 1.0 31.3 2 7-4 >60s 1321 >60s 876 876 43.8 3.7 26.5 2 LFG 8 >60s 1317 >60s 1074 1074 53.7 2.4 32.6 3 LFG 8A >60S 1318 >60S 1178 1178 58.9 0.1 36.1 10 LFG 8B >60s 1319 >60s 678 678 33.9 7.5 25.9 4 8-1 >60s 1315 >60s 1030 1030 51.5 2.1 37.7 2 8-2 >60s 1314 >60s 1108 1108 55.4 0.2 43.3 6 8-3 >60s 1313 >60s 966 966 48.3 1.6 39.2 2 8-4 >60s 1332 >60s 1112 1112 55.6 0.4 39.4 4 8-5 >60s 1335 >60s 914 914 45.7 1.7 36.1 2 LFG 9 >60s 1336 >60s 960 960 48.0 2.4 29.6 2 9-1 >60s 1337 >60s 628 628 31.4 2.5 31.2 2 LFG 10 >60s 1339 >60s 0 0 0.0 16.4 5.0 2 Old Maint Bldg >60s 1308 >60s 0 0 0.0 19.9 0.0 0 Electrical Shop >60s 1310 >60s 0 0 0.0 19.9 0.0 0 4 your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. DocuSigned by: $o"m E10B56EEF9EA34ED... SIGNATURE Environmental Technician TITLE DocuSign Envelope ID: 64E5DF4C-3B3C-4CC8-92BC-B8834D2217C6 This page intentionally left blank. DocuSign Envelope ID: 64E5DF4C-3B3C-4CC8-92BC-B8834D2217C6 f rsl y LFG-5 LFG-3 LFG- + 5 O LFG Probes 300 150 0 300 Feet on LFG-6 4. . 7-3 7-4 LFG-8 8-1 8-3 ° . � 8B 8-5 8-2 � _ 7-1 LFG-7 7-2 8A�• LFG-9 LFG-10 0 r� M cn Z O J U In O za Z Q Z w � O m J a o a o O a p� = tU Z > 0 O O Q O L Z C V 2 O LL LIA J r