Loading...
HomeMy WebLinkAbout6301_MooreCounty_MSWLF_CDLF_Sept2023LFG_FID1818523_20231002LENR USE ONLY ❑Paper Report [:]Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: 'NC DENR I IEnvironmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: • Prepare one form for each individually monitored unit. • Please type or print legibly. • Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). • Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. • Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). • Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): S&ME, Inc. (on behalf of Moore County) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Edmund Q.B. Henriques Phone: 336-288-7180 E-mail: ehenriques@smeinc.com NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) September 20, 2023 Moore County Landfill 456 Turning Leaf Way, Aberdeen, NC 63-01 .0500 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring x❑ Detection Monitoring Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑x Groundwater monitoring data from private water supply wells Leachate monitoring data ❑ Surface water monitoring data x Methane gas monitoring data Corrective action data (specify) Other(specify) Pilot Test Well Methane Data Notification attached? B No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. x0 Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Edmund Q.B. Henriques, PG Senior Geologist, S&ME Inc. 336-312-3330 Facility Representative Name (Print Title (Area Code) Telephone Number r _ A � �� 9/29/2023 Affix NC LiWs146?1# jop al Geologist Seal Signature V Date 8646 W. Market Street, Suite 105, Greensboro NC 27409 Facility Representative Address F-0176 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 12161% , W. B . 04 ��e, Table 1 Summary of Methane Gas Readings 2020 - 2023 Moore County Landfill (Permit 63-01) Moore County, North Carolina S&ME Project No. 4358-20-043A Location Scale- house g Point Type • 7 02/17/20 0.0% Maintena Shop • 0.0% Station • 0.0% Blake Crawlspace •V,f, 0.0% GP-9 0.0% r footn tel. 18.7% WUFMl! not installed 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% See footnote#2 0.0% 0.0% 0.0% 0.0% See footnote#1 11.9% Al 28.1% not installed r See footnote#4 not installed NEGEMEM See footnote#4 not installed 04/07/20 0.0% 0.0% 0.0% 0.0% 0.0% 32.2% not installed 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.4% 23.6% 59.9% not installed not installed not installed 09/15/20 0.1% 0.0% 0.0% 0.0% 0.1% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 0.0% 22.5% 0.0% not installed not installed 12/14/20 0.0% 0.0% 0.0% 0.1% 0.1% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.5% 9.6% 61.3% 0.0% not installed not installed 02/24/21 0.0% 0.0% 0.0% NM 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.4% 28.7% 67.9% 0.0% not installed not installed 04/12/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.2% 2.0% 21.8 % 0.0% not installed not installed 09/29/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.0% 19.5% 57.5% 0.0% not installed not installed 12/17/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 13.8% 27.8% 0.0% 10.1% 57.0% 03/25/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 29.1% 54.7% 0.0% 28.1% 56.4% 06/06/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 4.7% 42.4% 0.0% 30.5% 56.5% 09/26/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.1% 9.5% 50.8% 0.0% 13.7% 56.1% 12/16/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 1 0.0% 1 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 1 0.0% 2.9% 1 13.8% 56.5% 0.0% 27.4% 03/28/23 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.4% 6.9% 38.7% 0.0% 40.1% 06/08/23 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.4% 22.0% 49.9% 0.0% 36.8% 1367% 09/20/23 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 13.2% Notes: Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure Footnote#1 = MW-6 was replace by GP-19 as the property boundary compliance point. MW-6 is approximately 150 feet inside the property boundary and not a compliance point. Footnote#2 = GP-10 was replaced by GP-10R, GP-13 replaced by GP-13R, GP-14 replaced by GP-14R, GP-15 replaced by GP-15R Footnote#3 = Groundwater monitoring well MW-15 converted togas monitoring point now identified as GP-18, which is a property boundary compliance point. Footnote#4 = Gas monitoring points installed for a cancelled active gas extraction pilot test. A new passive venting pilot test has been proposed. all measurements recorded in percent methane by volume Lower explosive limit of methane gas: 5% Upper explosive limit of methane gas: 15% Data recorded prior to 9/15/20 obtained by Golder not installed = Well not installed at the time of monitoring Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point Orange highlight cells and values in bold print indicate methane percent by volume greater than or equal to 1.25% inside structures. T:\Greensboro-1s80\Projects\2020\4358-2-A Moore-W Routine LFG& WQ MonRoring\h. 08- Quarterly Methane Monitoring 202-24\LFG Re dmje Tables-<M1an NPROGRESS.rcIe, S1291-3 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Number: 63-01 Sampling Date: 09/20/2023 NC Landfill Rule (.0500 or .1600): 0.0500 Sample collector Name & Position: Gary Simcox / Environmental Technician (S&ME, Inc.) Gas Meter Type & Serial Number: GEM 5000 Plus / G504615 Field Calibration Date & Time: 9/19/.2023 Gas Meter Calibration Date: 9/19/2023 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 1/1/28 Gas Meter Pump Rate: 680 cc/min Ambient Air Temperature: 70 F Barometric Pressure (in. or min Hg): 30.16 Weather Conditions: Sunny Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) x 20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID Sample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES GP-9 60 0800 180 o.o 0.0 0.0 20.6 1.1 0.0 Property Boundary Monitoring Point GP-1 OR 1 60 0830 180 1 0.0 0.0 0.0 19.6 2.0 0.0 Property Boundary Monitoring Point GP-11 60 0820 180 o.o 0.0 0.0 17.85.3 0.0 Property Boundary Monitoring Point G P-12 60 0845 180 0.0 0.0 0.0 20.1 1.2 0.0 Property Boundary Monitoring Point GP-13R 60 0905 180 o.o o.o 0.0 19.3 2.4 0.0 Property Boundary Monitoring Point GP14R 60 0915 180 o.o o.o 0.0 18.4 2.6 0.0 Property Boundary Monitoring Point GP-15R 60 0930 180 o.o o.o 0.0 19.0 2.5 0.0 Property Boundary Monitoring Point GP-16 60 0940 180 o.o o.o 0.0 9.1 13.6 0.0 Property Boundary Monitoring Point GP-17 60 0955 180 o.o o.o 0.0 3.2 18.2 0.0 Property Boundary Monitoring Point GP-18 60 1030 180 o.o o.o 0.0 20.7 0.1 0.0 Property Boundary Monitoring Point G P-19 60 1005 180 o.o o. o 0.0 16.7 5.6 0.0 Property Boundary Monitoring Point NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the goSIbD�flltyOlf fine and imprisonment. Senior Geologist/S&ME, Inc. SIGNATURE TITLE Revised - February 4, 2020 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This.form and any information attached to it are 'Public Records"as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: 9/20/2023 NC Landfill Rule (.0500 or. 1600): 0.0500 Sample Collector Name & Position: Gary Simcox / Senior Technician, S&ME, Inc. Gas Meter Type & Serial Number: GEM 5000 Plus / SN 504615 Field Calibration Date & Time: 9/19/2023 Gas Meter Calibration Date: 9/19/2023 Field Calibration Gas Type (15/15 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 1/1/28 Gas Meter Pump Rate: 680 cc/min Ambient Air Temperature: 70 F Barometric Pressure (in. or mm Hg): 30.16 Weather Conditions: Sun Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial /o LEL Stabilized /o LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES MW-6 60 1145 180 0.0 0.0 0.0 20.7 0.1 0 not a compliance point GV-33 60 1135 180 > 100 > 100 46.9 0.1 36.4 0 Passive vent, not a compliance point GV-34 60 1125 180 > 100 > 100 40.8 0.1 36.5 0 Passive vent, not a compliance point GV-35 60 1120 180 > 100 > 100 13.6 13.1 10.8 0 Passive vent, not a compliance point GV-36 60 1045 180 > 100 > 100 22.4 10.8 17.9 0 Passive vent, not a compliance point Maintenance Shop 60 1150 120 0.0 0.0 0.0 21.2 0.0 0 on -site structure Transfer Station 60 1200 120 0.0 0.0 0.0 21.0 0.0 0 on -site structure Blake Residence 60 1230 120 0.0 0.0 0.0 21.1 0.0 0 off -site structure Scale House 60 1210 120 0.0 0.0 0.0 21.1 0.2 0 on -site structure GP-20 60 1015 180 > 100 > 100 13.2 1.6 23.1 0 Monitoring point, west of cut-off trench GP-21 60 1025 180 > 100 > 100 36.7 5.3 28.6 0 Monitoring point, east of cut-off trench NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations. for the. facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4°/, by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. i am aware that there are significant penalties for malting any false statement, representation, or certification includi g the pos. 'bility of a fine and imprisonment. �A�' Senior Geologist/S&ME, Inc. SIGNATURE TITLE Revised - March 6, 2017 ENVIRO-EQUIPMENT, INC. LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET Serial Number G5�1-Ik,l S Date Z.3 lnspectur �L7 Time/Date cu4— Battery Level [(='Ig Memory Cleared I Pump Faults Gas Alarms: CH, ;100.0% co, = 100.o% C�Ikg2W 02 = 22.0% 1 Zero Transducers 9�01 Pump Flow Rate b�Z c ��m in Vacuum Tested To 80" H2O WI� Calibration Gas Pure N2 High C114 High CO2 Low CHa Low CO2 Low 02 High 02 CO H2S Calibration Check (Performed at Room Temperature) Calibration Gas Concentration 007e 35n0 15�1. 150-l. Ia 20.9% 150 eerrA Lot Number 402Lk331g2. 4@ZS38N25 4011538425 12'51)422, 128'4J}22 4cD2y9'3�mg N/A 7 rA 1 Expiration I \ 2m 01 /2m28. m1 2 06 2m23 mb 201S m1 2mz8 N/A 0061Z025 m3 2 DZS Reading Accuracy* 60. I n. 3S. 1'7e 15. cD°lo 15.�'70 21. r — I m pprn t 2% t2% t2% t 2% f 2% t 2% t2% f 10% t 10% -Accuracy depends upon calibration range; 15°/aFS range for CF4 & CO2, 0-5%volume for Q, 0^/aFS for H2S, and 10% of reading for CO. INSPECTOR'S MAINTENANCE NOTES EF.1C M2000PlmUFm 01112