HomeMy WebLinkAbout6301_MooreCounty_MSWLF_CDLF_Sept2023LFG_FID1818523_20231002LENR USE ONLY ❑Paper Report [:]Electronic Data - Email CD (data loaded: Yes / No Doc/Event #:
'NC DENR I IEnvironmental Monitoring
Division of Waste Management - Solid Waste Reporting Form
Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Instructions:
• Prepare one form for each individually monitored unit.
• Please type or print legibly.
• Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification
must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing
condition, etc.).
• Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits.
• Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the
facility (NCAC 13B .1629 (4)(a)(i).
• Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste
Section, 1646 Mail Service Center, Raleigh, NC 27699-1646.
Solid Waste Monitoring Data Submittal Information
Name of entity submitting data (laboratory, consultant, facility owner):
S&ME, Inc. (on behalf of Moore County)
Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address:
Name: Edmund Q.B. Henriques Phone: 336-288-7180
E-mail: ehenriques@smeinc.com
NC Landfill Rule: Actual sampling dates (e.g.,
Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006)
September 20, 2023
Moore County Landfill 456 Turning Leaf Way, Aberdeen, NC 63-01 .0500
Environmental Status: (Check all that apply)
❑ Initial/Background Monitoring x❑ Detection Monitoring Assessment Monitoring Corrective Action
of data submitted: (Check all that apply)
Groundwater monitoring data from monitoring wells ❑x
Groundwater monitoring data from private water supply wells
Leachate monitoring data ❑
Surface water monitoring data x
Methane gas monitoring data
Corrective action data (specify)
Other(specify)
Pilot Test Well Methane Data
Notification attached?
B No. No groundwater or surface water standards were exceeded.
Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water
monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and
preliminary analysis of the cause and significance of any concentration.
x0 Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample
values and explosive methane gas limits.
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct.
Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas
levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there
are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment.
Edmund Q.B. Henriques, PG Senior Geologist, S&ME Inc. 336-312-3330
Facility Representative Name (Print Title (Area Code) Telephone Number
r _ A � �� 9/29/2023 Affix NC LiWs146?1# jop al Geologist Seal
Signature V Date
8646 W. Market Street, Suite 105, Greensboro NC 27409
Facility Representative Address
F-0176
NC PE Firm License Number (if applicable effective May 1, 2009)
Revised 6/2009
12161% ,
W.
B . 04 ��e,
Table 1
Summary of Methane Gas Readings 2020 - 2023
Moore County Landfill (Permit 63-01)
Moore County, North Carolina
S&ME Project No. 4358-20-043A
Location Scale- house
g Point Type •
7
02/17/20 0.0%
Maintena
Shop
•
0.0%
Station
•
0.0%
Blake
Crawlspace
•V,f,
0.0%
GP-9
0.0%
r
footn tel.
18.7%
WUFMl!
not installed
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
See
footnote#2
0.0%
0.0%
0.0%
0.0%
See
footnote#1
11.9%
Al
28.1%
not installed
r
See
footnote#4
not installed
NEGEMEM
See
footnote#4
not installed
04/07/20
0.0%
0.0%
0.0%
0.0%
0.0%
32.2%
not installed
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.4%
23.6%
59.9%
not installed
not installed
not installed
09/15/20
0.1%
0.0%
0.0%
0.0%
0.1%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
0.0%
22.5%
0.0%
not installed
not installed
12/14/20
0.0%
0.0%
0.0%
0.1%
0.1%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.5%
9.6%
61.3%
0.0%
not installed
not installed
02/24/21
0.0%
0.0%
0.0%
NM
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.4%
28.7%
67.9%
0.0%
not installed
not installed
04/12/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.2%
2.0%
21.8 %
0.0%
not installed
not installed
09/29/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
1.0%
19.5%
57.5%
0.0%
not installed
not installed
12/17/21
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
13.8%
27.8%
0.0%
10.1%
57.0%
03/25/22
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
29.1%
54.7%
0.0%
28.1%
56.4%
06/06/22
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
4.7%
42.4%
0.0%
30.5%
56.5%
09/26/22
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.1%
9.5%
50.8%
0.0%
13.7%
56.1%
12/16/22
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
1 0.0%
1 0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
1 0.0%
2.9%
1 13.8%
56.5%
0.0%
27.4%
03/28/23
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.4%
6.9%
38.7%
0.0%
40.1%
06/08/23
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.4%
22.0%
49.9%
0.0%
36.8%
1367%
09/20/23
0.0%
0.0%
0.0%
0.0%
0.0%
abandoned
0.0%
0.0%
0.0%
abandoned
0.0%
abandoned
0.0%
abandoned
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
13.2%
Notes:
Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure
Footnote#1 = MW-6 was replace by GP-19 as the property boundary compliance point. MW-6 is approximately 150 feet inside the property boundary and not a compliance point.
Footnote#2 = GP-10 was replaced by GP-10R, GP-13 replaced by GP-13R, GP-14 replaced by GP-14R, GP-15 replaced by GP-15R
Footnote#3 = Groundwater monitoring well MW-15 converted togas monitoring point now identified as GP-18, which is a property boundary compliance point.
Footnote#4 = Gas monitoring points installed for a cancelled active gas extraction pilot test. A new passive venting pilot test has been proposed.
all measurements recorded in percent methane by volume
Lower explosive limit of methane gas: 5%
Upper explosive limit of methane gas: 15%
Data recorded prior to 9/15/20 obtained by Golder
not installed = Well not installed at the time of monitoring
Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point
Orange highlight cells and values in bold print indicate methane percent by volume greater than or equal to 1.25% inside structures.
T:\Greensboro-1s80\Projects\2020\4358-2-A Moore-W Routine LFG& WQ MonRoring\h. 08- Quarterly Methane Monitoring 202-24\LFG Re dmje Tables-<M1an NPROGRESS.rcIe, S1291-3
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Moore County Landfill
Number: 63-01
Sampling Date: 09/20/2023 NC Landfill Rule (.0500 or .1600): 0.0500
Sample collector Name & Position: Gary Simcox / Environmental Technician (S&ME, Inc.)
Gas Meter Type & Serial Number: GEM 5000 Plus / G504615
Field Calibration Date & Time: 9/19/.2023
Gas Meter Calibration Date: 9/19/2023
Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 1/1/28
Gas Meter Pump Rate:
680 cc/min
Ambient Air Temperature: 70 F Barometric Pressure (in. or min Hg): 30.16 Weather Conditions: Sunny
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume) x 20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual
permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well ID
Sample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
% LEL
Stabilized
% LEL
% CH4
(volume)
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
GP-9
60
0800
180
o.o
0.0
0.0
20.6
1.1
0.0
Property Boundary Monitoring Point
GP-1 OR
1 60
0830
180
1 0.0
0.0
0.0
19.6
2.0
0.0
Property Boundary Monitoring Point
GP-11
60
0820
180
o.o
0.0
0.0
17.85.3
0.0
Property Boundary Monitoring Point
G P-12
60
0845
180
0.0
0.0
0.0
20.1
1.2
0.0
Property Boundary Monitoring Point
GP-13R
60
0905
180
o.o
o.o
0.0
19.3
2.4
0.0
Property Boundary Monitoring Point
GP14R
60
0915
180
o.o
o.o
0.0
18.4
2.6
0.0
Property Boundary Monitoring Point
GP-15R
60
0930
180
o.o
o.o
0.0
19.0
2.5
0.0
Property Boundary Monitoring Point
GP-16
60
0940
180
o.o
o.o
0.0
9.1
13.6
0.0
Property Boundary Monitoring Point
GP-17
60
0955
180
o.o
o.o
0.0
3.2
18.2
0.0
Property Boundary Monitoring Point
GP-18
60
1030
180
o.o
o.o
0.0
20.7
0.1
0.0
Property Boundary Monitoring Point
G P-19
60
1005
180
o.o
o. o
0.0
16.7
5.6
0.0
Property Boundary Monitoring Point
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility.
ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. I am aware that there are significant penalties for making any false statement, representation,
or certification including the goSIbD�flltyOlf fine and imprisonment.
Senior Geologist/S&ME, Inc.
SIGNATURE TITLE
Revised - February 4, 2020
NC Division of Waste Management - Solid Waste Section
Landfill Gas Monitoring Data Form
Notice: This.form and any information attached to it are 'Public Records"as defined in NC General Statute 132-1. As such, these documents are
available for inspection and examination by any person upon request (NC General Statute 132-6).
Facility Name: Moore County Landfill Permit Number: 63-01
Sampling Date: 9/20/2023 NC Landfill Rule (.0500 or. 1600): 0.0500
Sample Collector Name & Position: Gary Simcox / Senior Technician, S&ME, Inc.
Gas Meter Type & Serial Number: GEM 5000 Plus / SN 504615
Field Calibration Date & Time: 9/19/2023
Gas Meter Calibration Date: 9/19/2023
Field Calibration Gas Type (15/15 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 1/1/28
Gas Meter Pump Rate: 680 cc/min
Ambient Air Temperature: 70 F Barometric Pressure (in. or mm Hg): 30.16 Weather Conditions: Sun
Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office).
Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume.
Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL.
*Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See
individual permit conditions and/or Facility LFG monitoring plan.
Location or
LFG Well ID
S ample
Tube
Purge
Time of
Day
Time
Pumped
(sec)
Initial
/o LEL
Stabilized
/o LEL
% CH4
(volume)
% 02
(volume)
% CO2
(volume)
% H2S*
(volume)
NOTES
MW-6
60
1145
180
0.0
0.0
0.0
20.7
0.1
0
not a compliance point
GV-33
60
1135
180
> 100
> 100
46.9
0.1
36.4
0
Passive vent, not a compliance point
GV-34
60
1125
180
> 100
> 100
40.8
0.1
36.5
0
Passive vent, not a compliance point
GV-35
60
1120
180
> 100
> 100
13.6
13.1
10.8
0
Passive vent, not a compliance point
GV-36
60
1045
180
> 100
> 100
22.4
10.8
17.9
0
Passive vent, not a compliance point
Maintenance Shop
60
1150
120
0.0
0.0
0.0
21.2
0.0
0
on -site structure
Transfer Station
60
1200
120
0.0
0.0
0.0
21.0
0.0
0
on -site structure
Blake Residence
60
1230
120
0.0
0.0
0.0
21.1
0.0
0
off -site structure
Scale House
60
1210
120
0.0
0.0
0.0
21.1
0.2
0
on -site structure
GP-20
60
1015
180
> 100
> 100
13.2
1.6
23.1
0
Monitoring point, west of cut-off trench
GP-21
60
1025
180
> 100
> 100
36.7
5.3
28.6
0
Monitoring point, east of cut-off trench
NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations. for the. facility.
ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary)
Hydrogen Sulfide: >1% by volume (inside structures) AND >4°/, by volume (at facility boundary)
Certification
To the best of my knowledge, the information reported and statements made on this data submittal and attachments
are true and correct. i am aware that there are significant penalties for malting any false statement, representation,
or certification includi g the pos. 'bility of a fine and imprisonment.
�A�' Senior Geologist/S&ME, Inc.
SIGNATURE TITLE
Revised - March 6, 2017
ENVIRO-EQUIPMENT, INC.
LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET
Serial Number G5�1-Ik,l S Date Z.3 lnspectur �L7
Time/Date cu4— Battery Level [(='Ig Memory Cleared I Pump Faults
Gas Alarms: CH, ;100.0% co, = 100.o% C�Ikg2W 02 = 22.0% 1
Zero Transducers 9�01 Pump Flow Rate b�Z c ��m in Vacuum Tested To 80" H2O WI�
Calibration Gas
Pure N2
High C114
High CO2
Low CHa
Low CO2
Low 02
High 02
CO
H2S
Calibration Check (Performed at Room Temperature)
Calibration Gas
Concentration
007e
35n0
15�1.
150-l.
Ia
20.9%
150 eerrA
Lot Number
402Lk331g2.
4@ZS38N25
4011538425
12'51)422,
128'4J}22
4cD2y9'3�mg
N/A
7 rA 1
Expiration
I \ 2m
01 /2m28.
m1 2
06 2m23
mb 201S
m1 2mz8
N/A
0061Z025
m3 2 DZS
Reading Accuracy*
60. I n.
3S. 1'7e
15. cD°lo
15.�'70
21.
r —
I m pprn
t 2%
t2%
t2%
t 2%
f 2%
t 2%
t2%
f 10%
t 10%
-Accuracy depends upon calibration range; 15°/aFS range for CF4 & CO2, 0-5%volume for Q, 0^/aFS for H2S, and 10% of reading for CO.
INSPECTOR'S MAINTENANCE NOTES
EF.1C M2000PlmUFm 01112