HomeMy WebLinkAbout1403_Caldwell_Foothills_MSWLF_Cell6B_BlastingReport_FID1817442_202309011REPORT OF ROCK BLASTING AND SEISMIC MONITORING: CONSTRUCTION OF CELL NO. 613 FOOTHILLS REGIONAL MSW LANDFILL SOLID WASTE PERMIT NO. 1403-MSWLF-1998 REPUBLIC SERVICES OF NORTH CAROLINA, LLC CALDWELL COUNTY, NORTH CAROLINA SEPTEMBER 2023 R �i�►Z1 REPUBLIC SERVICES Republic Services, Inc. (2023) "�H CAROB •freer,,.• TV' 32249 ¢ :LNG'! N�`�?:. r T rH E W HODGES, HARBIN, NEWBERRY & TRIBBLE, INC. Consulting Engineers NC Corp License No. C-0813 3920 Arkwright Road, Suite 101 1 Macon, Georgia I Phone: (478) 743-7175 1 Fax: (478) 743-1703 Report of Rock Blasting 0 Cell No. 6B Foothills Regional Landfill Caldwell County, North Carolina September 2023 HHNT Project No. 6703-1142-01 TABLE OF CONTENTS TABLEOF CONTENTS............................................................................................................. 1 1. PROJECT INFORMATION............................................................................................. 1 2. ROCK BLASTING OBSERVATIONS................................................................................ 2 A. Vibration Blast Monitoring..........................................................................................2 B. Groundwater Level Measurements............................................................................2 C. Vertical Separation Requirements..............................................................................3 3. CONCLUSION..............................................................................................................4 FAJ]a►U][4�i Appendix A Rock Blasting Reports by Carolina Drilling, Inc. Appendix B Daily reports by BLE (on -site CQA Firm) Appendix C Seismic Analysis by Vibra-Tech Report of Rock Blasting 0 Cell No. 6B Foothills Regional Landfill Caldwell County, North Carolina September 2023 HHNT Project No. 6703-1142-01 1. PROJECT SUMMARY Blasting activities were required as part of the ongoing construction of Cell No. 6B at the Foothills Regional MSW Landfill, located on Cheraw Road in Caldwell County, North Carolina. This landfill is owned by Caldwell County, and operated by Republic Services of North Carolina, LLC. A formal Blasting Plan was prepared and submitted to NCDEQ for review and approval on May 1, 2023, in support of this request. This plan was reviewed and approved by the Solid Waste Section in a letter dated May 2, 2023. At this time, all blasting activities have been completed and all blasted material has been removed. A total of five (5) blasting events were performed between May 10, 2023, and May 19, 2023. As required by the Section's approval letter, we are providing the Blasting Summary Report to document the blasting activities that were performed in association with the blasting work. This report includes: • Final volume of rock removed. • Rock blasting observations including copies of all blasting reports and vibration monitoring data. Note: The following information has been included in the "Geologic Observation Report: Cell No. 6B," prepared by Bunnell Lammons Engineering and dated September 11, 2023. This information has not been duplicated in this Blasting Summary Report. • Rock Blasting Plan (FID 1792134) • Rock Blasting Plan Approval Letter (FID 1792135) • Vertical Separation Demonstration • Water Level Measurements A copy of these reports will be included in the final CQA Report for the project. Due to the wet weather over the last several months and the volume of blasted material required to be moved, it has taken additional time for the general contractor to remove all the blasted material so that final, top of rock survey shots could be obtained. We appreciate the Section's willingness to grant an extension on this submittal. Report of Rock Blasting 0 Cell No. 6B Foothills Regional Landfill 0 Caldwell County, North Carolina September 2023 1111iHNT Project No. 6703-1142-01 2. ROCK BLASTING OBSERVATIONS During the construction of Cell 613, a zone of rock located within the proposed cell was blasted, excavated and removed so that the cell design grades could be achieved. The general area of rock blasting within Cell No 6B is shown in the approved Blast Plan. A blasting plan was prepared by Carolina Drilling, Inc (a subcontractor to Earnhardt Grading, Inc.) and submitted by HHNT to the North Carolina Department of Environmental Quality (NCDEQ) on May 1, 2023. The Blasting Plan was approved with conditions by the NCDEQ as specified in their letter dated May 2, 2023. Following NCDEQ's approval, the first blasting event was performed on May 10, 2023 after providing the required notice to NCDEQ. In total, approximately 50,000 CY of rock material was blasted and removed to achieve the required design grades. A. Vibration Blast Monitoring Five (5) rock blasting events were performed between May 10, 2023, and May 19, 2023, by Carolina Drilling, Inc. Vibration monitoring was performed by Vibra-Tech, Inc. of Fort Mill, South Carolina. The rock blasting reports are included in Appendix A. In addition, Daily Reports which were prepared bythe on -site CQA Firm (Bunnell Lammons Engineering) have been enclosed which document project activities each day, including blasting. These reports have been included in Appendix B. The seismic analysis and monitoring data has been included in Appendix C and includes information regarding the date, time, station identification and vibration monitoring results from each seismograph utilized during the blasting activities. A total of three (3) seismographs were used to monitor vibration for this project. These locations were selected and used interchangeably as appropriate, which included: • Location 1— Top of Berm • Location 2 — Closest Monitoring Well (MW-11) • Location 3 — Between the scale house storage trailer. The specific limitation of peak particle velocity (PPV) in the approved blasting plan is 1.0 inch per second (ips) to the nearest protected structure. In this case, Location 3 represents the seismograph that was used to monitor PPV at the nearest structure. Each of the reported vibration results were less than the 1.0 ips with a maximum of 0.771 ips (Location 1 on May 12, 2023). B. Groundwater Level Measurements Groundwater levels were measured in the closest groundwater monitoring well, as requested by NCDEQ. A pre- and post -blast water level was taken from groundwater monitoring well MW-11. The head difference in the pre -and post -blast water levels of the groundwater monitoring well sampled showed no significant change in head. A summary of the collected water levels is included in BLE's "Geologic Observation Report: Cell No. 6B. 2 Report of Rock Blasting 0 Cell No. 6B Foothills Regional Landfill 0 Caldwell County, North Carolina September 2023 1111iHNT Project No. 6703-1142-01 C. Vertical Separation Requirements At the completion of blasting, after the general contractor (Earnhardt Grading) had removed the blasted material, survey data were obtained by Earnhardt and submitted to HHNT for review and confirmation of vertical separation. Using this survey data, HHNT prepared a surface so that the entire area could be evaluated against the Cell 6B base grades. Upon our review, almost all the areas evaluated met, and in many cases exceeded the minimum 4' of separation required by the NCDEQ Solid Waste Rules. There were a few isolated areas along the edges of the blasted area that did not meet the required 4' separation requirement based on the survey data. In an effort to confirm separation, HHNT selected points within these areas, which were located in the field so that the contractor could excavate down at those locations to see if the required depth could be achieved. Additional rock was removed at these locations using a rock hammer and the areas were re -surveyed. The survey data was reviewed by HHNT to confirm the required separation from rock had been achieved. A sketch was included in BLE's "Geologic Observation Report: Cell No. 613" which shows the top of rock as -built data provided by the contractor and the separation that was achieved below the design bottom of clay grades in Cell 6B. Based on our detailed review of the data, all areas meet or exceed the required separation within the Cell 6B area. 3 Report of Rock Blasting 0 Cell No. 6B Foothills Regional Landfill 0 Caldwell County, North Carolina September 2023 1111iHNT Project No. 6703-1142-01 I CONCLUSION All blasting activities that have been authorized by the Solid Waste Section have been successfully completed. Results of all monitoring activities have been compiled and presented in this Blasting Summary Report, and/or BLE's "Geologic Observation Report: Cell No. 6B", which was submitted under separate cover. 4 Report of Rock Blasting 0 Cell No. 6B Foothills Regional Landfill 0 Caldwell County, North Carolina September 2023 111i1-INT Project No. 6703-1142-01 APPENDICES APPENDIX A: ROCK BLASTING REPORTS Cd1ofim odfto 1= Ph:336-751-2961 %Aftf*Mjflk Mew 2770Q s irs�a s3�-751�ii � �� �'E CONTRACTOR �G rn in �� i s LM ON SITE MAP Jos NAm F-9 Jos CATION _ Gen , " N Lc , DATE.• j= j© ZY s, , 3 o Qi�vi �... c, v WEATW?g. WIND DIREMON CEu.II+IG: SEISMOGRAPH LOCATION I.P.S. � FREQ. Ds r r EXPLOSWES TYPE SIZE DATE CODE POUNDS 2 A ,,, .A 5 TP7 UAj- f i j TOTAL= 9, U ► i P OWMEM MQ— M Y?—j 1 TYPE OF BLASTING CAPS ; #USED SCALE DISTAI+IC£ _ �_--------- #SURFACE DELAY USED #9 #I7 #42 # Of Hole Bole Suit Stem # of Holes Min. RM Max. %s. Ho%s Dia. Depth Dn* tg dqjth pea Delay per Delay perDelay TYPE OF ROCK _ OVER BURDEN 0 TYPE OF COVER O TRENCH Diamond Staggered Parallel spacing - Width Length Depth of Invert SIZE OF PIPE TYPE OF PIPE EST. VD.b 5J, 3 1 MASS: Bm4t Spacing 7 -�'--7 Paimer Avg. cut C�nttaa b01 s )c Y, 5"=Z? = 57,a3 Bol#2- canorinat Orlaill8p Inc. Ph: 336-751 2961 326 Railroad St. Mocksville, N.C. 27028 Fax: 336-751-0774 BLAST DEPORT CONTRACTOR 4 k,--G"/'-�c�r , LOC_ ON SITE MAP JOBNAME I s""' ,7� .+ %-e JOB LOCATION DATE: - Z - Z TIME:--t--->1- AMLm� TEMP. WEATHER: C ld -e, �= WIND DIRECTION: �_ CEILING: I, EtAPH� /LO�CATI jON I.P.S. FREQ. DB 2 3 LIES TYPE SIZE DATE CODE POUNDS 1 An4v Lk TAt-u i<L 4 5 TOTAL = / / U POWDELBS PER YD: i �' �` R: TYPE OF BLASTING CAPS S�' #USED SCALE DISTANCE ##SURFACE DELAY USED #9 #17 � 2' # Of Hole Hole Sub Holes Dia. Depth Dialling Stem depth # of Holes Min. Ibs per Delay per Delay Max. lbs. per Delay TYPE OF ROCK �'��' � OVER BURDEN TYPE OF COVER Ci TRENCH Diamond Staggered Parallel Spacing Width Length Depth of Invert SIZE OF PIPE TYPE OF PIPE EST. YD. r MASS: Burden Spacinj2LLI Perimeter Avg. cut VVV Comments: t-� s X 13 3- f, 17 , 7 75-®. Cam&w DASWj Im Ph 336 751-29+61 3Rm�oad st fie, N 27028 Faz 336 75I-OTl4 BLAST REP(?RT CONTRACTOR LOC_ ON SITE MAP Shot # JOB NAME F114k c 1 t C; n L� I A111-4-c JOB LOCATION DATE ./ 5 - Z 3 TRAE: , AM M TEW. WEAVER C D L WIND DIRECTION: � � CEa-ING: 44 j s ' -- IASIM / TYPE SIZE dL DATE CODE POUNDS /� 1`�I D In 2. 2 �12 1t-7 ? � L POWDER: LBS PER YLT._ I t� TYPE OF BLASTING CAPS 2f ' i'��'f 1 # U� C SCALE DISTANCE �17 �2 #S`URFACE DELAY USED #9 # Of Hole Hole Stab Strom DrMing depth # of Axles Per DidaY Ivfm. Ibs Mac. Ibs. per Devi' per Delay Haim Dia. Depth TYPE OF ROCK q°``""`� t OVER BURDEN TYPE OF COVER_ Tiz.ENCH D M and Soared Parallel Spacing Width Length Depth of Invert SIZE OF PIPE PE OF PIPE �T �� TYPE r� 7 rJk Para Avg. cat y L S - MASS: Btud�l � Comm: cQmaw oriirvw. lm. Pti: 33Cr751-2951 t� 320 rear"St b!2tZ le N C 27028 Fax: 33, 751-0774 BLAST R.EPOR.T CONTRACPOR L Fey, �I.y-�*� l t edLl� LOC. ON SITE MAP Shot # _ loo— JOB NAME f0,+R' PS JOB LOCATION DATE: 5 "/�-2- m TD4E: . d L � TEMP. 1e/ WEATHER: C' 0 `tC 1,- 7 WIND DIRECTION: CEII.ING: j TYPE 1 SIDE I DATE CODE I f ,2 .f POWDER_ LBS PER M.-- SCALE DISTANCE_ TYPE OF RLAS ING CAPS #SURFACE DELAY USED #9 # Of Hole Hole Sub Sim Holm Dia. Depth DrMiag dqXh I 0 I I I q # I 7_ _ 442 # of Holes Nf m lbs Mac_ Tbs. per D,.-* per Dew' Du Dew TYPE OF ROCK &`t'^' - OVER BURDEN � TYPE OF COVER Parallel SpacmS width � Depthof Invert 'I'KEIHCB Iliamand Sly l/ SUE OF PIPE TYPE OF PIPE EST. YD. J 7 MASS: Biudw i`nacme '%7-' Rmimda Avg. cut Commcw: ��/x, Ao7�1 12r/ycf camcow — " — g., Ina PtL 336-75I-2961 326 Rm.'oad SL bjz&&iN.C. 27028 Faz 336 751-0774 BLAST REPORT CONIRAC OR ;Vi W � � LOC_ ON SITE MAP �a Shot # JOB NAME Tb+tt i )�5 enuTi*rd JOB LOCATION DATE: SDI % - _ TIME: 0 n AMFM TIlAP. WEATHIR�ld(A6 WINDDIRECITON: CEILING: / SEISMOGRAPH LOCATION U.S. _ FREQ. DB LOSJVES TYPE SIZE DATE CODE PO 5-0 _ i5-0 5' o TMAT 0211 POWDER: LBS PER YD:�� SCAM DISTANCE_ #SLWACE DELAY USED #9_ Of Hole Hole Holes Depth f 1,f - TYPE OF ROCK TYPE OF BLASTING CAPS (Pe,)G1;2- #I7#42 Stem # of Holes Nfm. lbs Mu- lbs. depth Per Delay per Way Da Delay OVER BURDEN TYPE OF COVER Sub Dnildug TRENCB Diced wed Parallel Spacing Width SIZE OF PIPE TYPE OF PIPE - MASS: B►indw S�acmg ) f6�X�x� Length Depth of Invert Avg. cut APPENDIX B: DAILY REPORTS IMBUNNELL LAMMON5 ENGINEERING RECORD OF DAILY OBSERVATIONS FOOTHILLS REGIONAL LANDFILL CONSTRUCTION QUALITY ASSURANCE - CONSTRUCTION OF CELL NO. 6B CADWELL COUNTY, NORTH CAROLINA BUNNELL-LAMMONS ENGINEERING, INC. PROJECT NO. 1235-109 HHNT-INC, PROJECT NUMBER 6703-1142-01 CLIENT: Republic Services of North Carolina, LLC DATE: 05/10/2023 Project Day Number 31 ARRIVAL TIME: 7:15 Notice to Proceed Date: 04/10/2023 DEPARTURE TIME: 20:45 WORK HOURS: 13.5 VISITORS: NAME REPRESENTING ONSITE BLE PERSONNEL: Brian Bunvard WEATHER: ❑✓ SUNNY ❑✓ RAIN TEMPERATURE APTLY CLOUDY ❑WINDY MORNING LOW: 51 °F ❑ CLOUDY DAYTIME HIGH: 78 °F SITE ACTIVITIES ❑✓ SITE PREPARATION ❑ GEOSYNTHETICS INSTALLATION ❑✓ OTHER ❑ STRUCTURAL FILL ❑ LEACHATE COLLECTION SYSTEM ❑ COMPACTED SOIL LINER ❑ DRAINAGE LAYER CONTRACTOR ACTIVITIES: Earnhardt Grading, Inc. 1) BLE met and coordinated with job superintendent Richard Ratliff about blasting schedule and MW-11 measurements and procedures before and after blasting activities. 2) Contractor used a Cat 349 excavator and 2 off road Cat 745c trucks to excavate and transport excavated soils to staging areas. 3) Contractor stripped topsoil from northeast section of project area in preparation for toe key excavation/installation. Material was collected using CAT 349 excavator and transported using CAT 740B off road haul trucks. 4) Carolina Drilling, Inc. was on site drilling holes for blasting and previously drilled holes were blasted. MW-11 water levels were measured before and after drilling. The water level at 12:30 pm before blasting was 83.54 feet. The water level at 4:00 pm after blasting was 83.5 feet. CONSTRUCTION ISSUES: N/A TECHNICIAN ACTIVITIES: 1) Observed and documented contractor activities mentioned above. RECORD RFVIFWF & APPROVED BY: Jonathan P. Usher, P.E. Signature '6004 Ponders Caurt, Greenville, SC 29615 f,864,288,1265 @N864.288.4430 ?fnfo@blecorp,com BLECORP.COM Rev 2,10 / rea of topsoil FRo oTE ,� n � NERNVPI ximate area �3f° E Ep°� � / ��,ryO: AREas TD PRomom� ED 1� fmRl! EXISTING CELL NO. 8A PROPOSED CELL NO. 6B EXISTING CELL NO 6 BENCHMARKS BM NO. NORTHING EASTING ELEV. DESCRIPTION 1J1�FF� AN F. �NrRAMORLLNEN��LDEN NM RNNFORMATONANDNOTFYENGINEER NVDF�DEDREArvDEs NOsHMARRELDTEDDDTSDEHELMTs�THEEHEE: DIDATE o <oM ED T.' Po�aA Approximate area NFORMATONPRO DEDBYFRMAT LLO,DATEDIUNE1, zozz, pf,p vation ° ' �� sHOG� FELDCHEONEDFOPPELABLT. EETMPPNOETrvGRDSAND f FBY � Mw oFELI1111oGLAN s1R�rN.F"1RONANGUR�E.FER 'EorvoDroRE IS —EIIESENTIr RDE �FLLDR READ SURFACE. NETD STRUDTDF ALL R� O�mFURED=N RE 8 NDTED SLOPE EMRANNAENsSHOWN RE,H, DrvLEEEDT�RwNE ® RETE—OCAorvATE—HrHE EXISTING �., owNERPwoaro NUTeau DELrvERv Ll CELL NO 5B FACT ES Ll s \\ BNE CANT 11IIAcrvcoURN REVAINUPON ING IG CONSTRUCTION, oN�rRRAN OR EXISTING NAOEMENT rvTHE ceu REAIs.oRMw 1. CELLNO.5A ' UNrNPR LFNU AccERrANCE oSLEf THEceu DrucoTERED. BASINBE RESPONSIBLE FOR RESTORING WET D—ON �sALrvopEA pFiiLD� \ cNI TO 7TE oNSTRucrloN ruraucnoN corvomon uPory rHE coMPLEnon of AT BY u . �OcaT� ,sszez , ��\\\ OC LINER. N11— LvoRLEFrINFucEWHEREPTERED ossB�FORFUTUREUSE S_ \ — ED Iin ownD tr P,'TH:AT N BE � is asn FNTR fl` ACITHsoE.,-INN NOR.ER To GF'FRM HE F DESIGN GN TAITED OR REvsorvDETRs ARE PROUREIR D. or sno\� weu� IS rrvP.l wn7 - ADD 110N. INSTALLATION OF A TOE ON N ALONG THE BE �l �� A RTARLN DHETALLEDwNHETHER OPTION TOMPROVELONGTERMSLOPE EXISTING ( CELL NO. 3C Ew EXISTING j iw io CELL NO. 2B �E Ew"% !EXISTING ,00 so o ,00 zoo Wz GRAPHICscaLE INFEET CELL NO. 36 ,no PROPOSED DRAINAGE STRUCTURES WPIPE NO, SIZE LENGTH SLOPE IMTERWL EXISTING T100 30' S5' 100% CPP ` TOP OF SO L L NERD Nc PLAN CELL NO.4 PROPOSED FLARED END SECTIONS CONSTRUCTION OF CELL NO. 6B �\ .. No. ELEv. o. ELEv. r FOOTHILLS RE FOR LANDFILL T, ,121.90 T2 ,12a.00 REPUBLIC SERVICES OF NORTH CAROLINA LLC �_-" CALDWELLCOUNTV BOARD OF COMMISSIONERS c oa`: wts �NaRmp DuxA o ,vP REPOBLIIC rt{�N FvvkniivIHc v-w"s B,m,D,l„M-NOmAm zz -- "� SCALE 3 OF,ona� IMBUNNELL LAMMON5 ENGINEERING RECORD OF DAILY OBSERVATIONS FOOTHILLS REGIONAL LANDFILL CONSTRUCTION QUALITY ASSURANCE - CONSTRUCTION OF CELL NO. 6B CADWELL COUNTY, NORTH CAROLINA BUNNELL-LAMMONS ENGINEERING, INC. PROJECT NO. 1235-109 HHNT-INC, PROJECT NUMBER 6703-1142-01 CLIENT: Republic Services of North Carolina, LLC DATE: 05/12/2023 Project Day Number 33 ARRIVAL TIME: 7:00 Notice to Proceed Date: 04/10/2023 DEPARTURE TIME: 17:30 WORK HOURS: 10.50 VISITORS: NAME REPRESENTING ONSITE BLE PERSONNEL: Stephen Mitchell WEATHER: ❑✓ SUNNY ❑RAIN TEMPERATURE ❑PTLY CLOUDY ❑WINDY MORNING LOW: 58 °F ❑ CLOUDY DAYTIME HIGH: 82 °F SITE ACTIVITIES ❑✓ SITE PREPARATION ❑ GEOSYNTHETICS INSTALLATION ❑✓ OTHER ❑ STRUCTURAL FILL ❑ LEACHATE COLLECTION SYSTEM ❑ COMPACTED SOIL LINER ❑ DRAINAGE LAYER CONTRACTOR ACTIVITIES: Earnhardt Grading, Inc. 1) Carolina Drilling, Inc. detonated previously drilled charges at approximately 12:00 om. Water level measurements from MW-11 read 83.65 feet at 10:30 am prior to blasting, and 83.60 feet 1:30 pm after blasting. 2) Earnhardt installed toe key in the northeast section of the project area. The toe key was excavated to a depth of 10 feet below the existing ground surface. Rocky fill material was transported using CAT 740B off road haul trucks, and spread using CAT D8T Bulldozer before being compacted using CAT padfoot compactor. 3) Earnhardt backfilled the previous day's excavation to remove soft organic soil. Fill material was deposited using CAT 740B off road haul trucks and spread using CAT D8T bulldozer before being compacted using CAT padfoot compactor. 8-inch loose lifts of structural fill were placed. CONSTRUCTION ISSUES: N/A TECHNICIAN ACTIVITIES: 1) Observed and documented contractor activities mentioned above. 2) Met with Richard and Charlie to discuss the requirements in the specifications for the composition of the rock fill material. RECORD SEA & APPROVED BY: Jonathan P. Usher, P.E. Signature '6004 Ponders CauM Greenville, SC 29615 IL864.288.1265 A864.288.4430 PInfo@bleeorp,eom BLECORP.COM Rev2,0 5/12� /2023 Earnhardt IC II installed toe key r �� __ in this approximate n area WIM ,o, �I � PNG 1 BENCHMARKS So�NE If BM NO. NORTHING EASTING ELEV. DESCRIPTION A ' \c — Approximate \ . area of - EBBENGHMAMEELLOO,E IWIPYALL THEE s1OF,�SHEET "orvoT�ErvGIrvEER excavation backfill. NO G-�T; POOIDATE_=o N=1NFORMATONPRO DEDBYFRMAT ILODATED,UNE11.11, DGWO1. OONE FE,:°EETMAPPNGSTANDARDSAN HOG�BLoOHEOEDFORELFL ow o sOR soFTNE�ORSO ON STREaMG Now n No wOREP a OEO ER -- �RONTarvoFELOS NOSGR NGFROMasGRE.PERFORMEONGGTORER ' pproximate 'B" area of blasting wpER STRUGTGRaLFLLORREAD GI,RFaCE EMREPREGENT REPRESENT NETOPO, BmFa�D , AU OUTSIDE SLOPE EMBANWEN<BSHOWN ARE ZHIVUNLESS OTHEMME O. 11 \® B NrvNNw�NNOT BNOEa RRCT EGRETETOB�� EOPRORTO EXISTING �. TT.HE PU.'RA TowO ROHDERUPON -THE COMPLEnory OFCONSTRGCnON CELL NO SB a '0,\� RSTXMZARaN OR EXISTING CONTRACTOR IS RESPONSIBLE FOR STORM WATER MANAGEMENT 11 THE CELL ,`� rREgt? ROPEarER 1 CELL NO. 5A UNTILINAL ACCEPTANCE of THE CELL Br NI DEC BE RESPON-LE FIR REITORINI WET PROPOSED mP E 0 STRGCTON NSTRUCTONCON,TOPUPONTHEGOMME ONOF IN t 01 CELL NO. 6B N ACRE11 S) ss�e \ \ A���\\ owNDRA lry trrP., LNER LvoRLEFEN T NO WIRI WHERINC ERED PCE PossB�IS FORI IS TIEXUSEABLY BASED 1111 ON THE T___HY EMET THIS ILAN TNGDESON NORDER,ODETERMNE RTO FDESGNR sONGARECONTACTED PRR DDR D �M oTBHo ,rP, END NEENN. N. ° \ BE DNSTALLEDwNHETHER OPTONALONETOTHEMPROVELUNGTERMSLOPE _DY EXISTING � CELL NO. 3C w EXISTING CELLNO.2B \E —� EXISTING Su' CELL NO 6A W31 ? AROUND PADRN II _ w ,DD sO D ,DD zDD ! EXISTING GRAPHIC SCALE INFEET s CELL NO. 3B WTnB L'T NO GERrTva) E�-L� PROPOSED DRAINAGE STRUCTURES=�o- 1 J PIPE ND. SRE LENGTH SLWE 1MTERWL —J T100 30' S5' 100% CPP ` EXISTING CELL NO.4 TOP OF SG L L NER GRAD Nc PLAry y {�� pROPoNG FLARED END SECTIONS CONSTRUCTION OF CELL LANDFILL 6B ��\ No. ELEv. No. ELEv. r FOOTHILLS REGIONAL LANDFILL T, ,128.90 T2 ,12a.BB REPUBLIC SERVICES OF NORTH CAROLINA, LLC tig EXISTI�EW '4� T CALDWELL COUNTY BOARD OF COMMISSIONERS - CELL NO. BA � ,� c ®a: wts wrvO�p CuxA \\\`l - NgvgH B�kni{vINc ,vwaa �� REPU8111C ��mnces SCALE I —DC �„sEFSHEETE 3 OFu7 wren BUNNELL LAMMONS ENGINEERING RECORD OF DAILY OBSERVATIONS FOOTHILLS REGIONAL LANDFILL CONSTRUCTION QUALITY ASSURANCE - CONSTRUCTION OF CELL NO. 611 CADWELL COUNTY, NORTH CAROLINA BUNNELL-LAMMONS ENGINEERING, INC. PROJECT NO. 1235-109 HHNT-INC, PROJECT NUMBER 6703-1142-01 CLIENT: Republic Services of North Carolina, LLC DATE: 05/16/2023 Project Day Number 37 ARRIVAL TIME: 7:00 Notice to Proceed Date: 04/10/2023 DEPARTURE TIME: 18:00 WORK HOURS: 11.00 VISITORS: NAME REPRESENTING ONSITE BLE PERSONNEL: Steohen Mitchell WEATHER: ❑° SUNNY ❑RAIN TEMPERATURE ❑ PTLY CLOUDY ❑ WINDY MORNING LOW: 62 °F ❑ CLOUDY DAYTIME HIGH: 85 °F SITE ACTIVITIES ❑✓ SITE PREPARATION ❑ GEOSYNTHETICS INSTALLATION ❑✓ OTHER ❑ STRUCTURAL FILL ❑ LEACHATE COLLECTION SYSTEM ❑ COMPACTED SOIL LINER ❑ DRAINAGE LAYER CONTRACTOR ACTIVITIES: Earnhardt Grading, Inc. 1) Earnhardt backfilled area in the east project area. Fill material was placed using CAT 740B off road haul trucks and spread using CAT D8T and CAT D5K bulldozers before being compacted using CAT padfoot compactor. 2)Carolina Drilling blasted section of project area at approximately 2:30 pm, and continued preparation of next area. BLE measured water levels in MW-11 before and after the blast. Pre blast reading was measured to be 83.8 feet at 12:45 pm, and post blast reading was measured to be 83.75 feet at 3:15 pm. CONSTRUCTION ISSUES: N/A TECHNICIAN ACTIVITIES: 1) Observed and documented contractor activities mentioned above. RECORD RIAB,& APPROVED BY: Jonathan P. Usher, P.E. Signature '6004 Ponders Court, Greenville, SC 29615 t.864,288,1265 a ,864,288.4430 'p—MInfo@blecorp.Com BLECORP.COM Rev 2.10 I EDGEOFL tiERmv.> MR -All Ire/Nr CELL NO. 6B "7-S EXISTING -� AR, R...�.. EXISTING CELL NO. 8A x area of II pproximate 63 area of blasting \. TAI =H \ � = ess `ti I qq°eP EH111111 1 U11Tv� lJ EXISTING ( CELL NO. 3C / pa)GTON-1 EXISTING CELL NO. 36 BENCHMARKS \ BM NO. NORTHING EASTING ELEV. DESCRIPTION I\CONCRETE PAMBIL 'DOW INNEGIATELV LVERIANYB IALIF ECREPANGIEE NFORNATIONANGN1TIBY1 GINEER NOTES:BENCHMA TED OUTSIDE THELIMITS OF THIS 16T1O1RAPHOTOR�NFGEA'ONPRG'GEGa ODPERAIRNLSORE--(GATE NFORMATGNPR° DEDBYFRMA,EB,LUI NEGWITHTGPG 1). G,DATEG,UNTo, zoz2, 2. CONTOURS INSIDE VEGETATED AREAS MAY ARDS AND W.,N 3 SH=FFELDCHEGNEGFGR'EL -LT. EETMPPNGETNDGOGE AID SSNGAD ING ALL �L�EsS� a E SLOPEM�MHOw ARE NOEo ALF 66 LOCATION 01 ALL GWNERPRIORTOMATERIALDELNER�. RETGREGGORONATEGWRNTNE PRIOR To FACT ES (111] ' THE PRae°T IIE woNc rvG oROERuRD THE comaLEnoNTor CONSTRUG ON, EXISTING aC ONTRACTOR IS RESPONSIBLE FOR STORM WATER MANAGEMENTN THE CELL CELL NO SA \ ;UNTIL FINAL E� NCONSTRUCTION. ITSN PRE -CONSTRUCTION CONomCOMM oN UPON THE COMETION OF IN � ELYORLEPTINPFACEWHEREPOERIURPORPUTUREUSE ASSGIL L HER12, THE DESIGNIENGINEERING WORK SHOWN ON THIS SHEET IS EXCLUSIVELY BASED RE"REN'F ANYOFT CO. ONTO, NA ELLD BE CONTACTED PRIOR TNS DESONN ORDER TO OETERM HE F OESGN REVISIONS ARE REQUIREDADD 1IOM INSTALLATION OF A TOE D" N ALONG THEI—CATE—THILCTILRAL FILL —HE. OF 2-V MIST.E ENHANCED BY STR DO 'AG AN E'VAU, EBB COMPACTED ILL 11R THE LOWER PORTION OF THE IN. " BILL ALTERNIVELI DESUE GNGTLEDWNHETHERGPTGNGMPRGELGN TEALLRM STAENBE BY EXISTING CELL NO. 2B �E IOO so O ,OO zoo W13 GRAPHIC SCALE IN FEET GG*Sx , t ` IAGE STRUCTURES— 7,2�, JII� I PIPENO. EGM LENGTH SLOPE 1MTERWL E— EXISTING T, U 30' 5E' 100% CPP TOP OF SCIL LINER GRADING RAN CELL NO.4 PROPOSED FLARED END SECTIONS CONSTRUCTION OF CELL NO. 6B o. ELEv. r FOOTHILLS REGIONAL LANDFILL MR 11 T, 1121.90 T2 ,12a.ES REPUBLIC SERVICES OF i NORTH CAROLINA LLC T CALDWELL COUNTY BOARD OF COMMISSIONERS C oa`: wts wNamNp CuxA ,ve REPOBLIIC It{�N E�kniivIHc mAm mnces PROU,NI+, zz FSHEETE -- "� SCALE 3 OF�ona� BUNNELL IM LAMMONS ENGINEERING RECORD OF DAILY OBSERVATIONS FOOTHILLS REGIONAL LANDFILL CONSTRUCTION QUALITY ASSURANCE - CONSTRUCTION OF CELL NO. 6B CADWELL COUNTY, NORTH CAROLINA BUNNELL-LAMMONS ENGINEERING, INC. PROJECT NO. 1235-109 HHNT-INC, PROJECT NUMBER 6703-1142-01 CLIENT: Republic Services of North Carolina, LLC DATE: 05/18/2023 Project Day Number 39 ARRIVAL TIME: 7:00 Notice to Proceed Date: 04/10/2023 DEPARTURE TIME: 16:30 WORK HOURS: 9.50 VISITORS: NAME REPRESENTING ONSITE BLE PERSONNEL: Stephen Mitchell WEATHER: QSUNNY ❑RAIN TEMPERATURE ❑PTLYCLOUDY ❑WINDY MORNING LOW: 62 °F ❑ CLOUDY DAYTIME HIGH: 85 °F SITE ACTIVITIES ❑✓ SITE PREPARATION ❑ GEOSYNTHETICS INSTALLATION ✓❑ OTHER ❑✓ STRUCTURAL FILL ❑ LEACHATE COLLECTION SYSTEM ❑ COMPACTED SOIL LINER ❑ DRAINAGE LAYER CONTRACTOR ACTIVITIES: Earnhardt Grading, Inc. 1) Earnhardt backfilled area to the east of the project area. Structural fill material was placed using CAT 740B off road haul trucks and spread using CAT D8T and CAT D5K bulldozers before being compacted using CAT padfoot compactor. 2)Carolina Drilling blasted section of project area at approximately 12:00 pm, and continued preparation of next area. BLE measured the water levels in MW-11 before and after the blast. Pre blast measurement was 83.70 feet at 10:45 am, and post blast measurement was 83.70 feet at 12:45 pm. CONSTRUCTION ISSUES: N/A TECHNICIAN ACTIVITIES: 1) Observed and documented contractor activities mentioned above. RECORD REVIEWED & APPROVED BY: _ Jonathan P. Usher, P.E. Signature 6GI14 Ponders Court, Greenville, SC 29615 1�864.288.1265 H864.288.4430 '-5infofhlerorp.Lom BLECORP.COM Rev 2,0 5/18/2023 I CELL NO. 6B - KEXISTING A ELL NO 16 AN OUNSTPAD EXISTING CELL NO. 6A , area of backfill - MINT area of blasting '—, \\ PROPOSED SPQR \\� _�.. N % BE TRA\ 112 1 Tz I- lJI\} EXISTING ' ( CELL NO. 3C BENCHMARKS BM NO. NORTHING EASTING ELEV. DESCRIPNON RON ASEAN IS All ABRAN HIENCHMANNE LOCATED OUTSIDE THELIMITS OF THIS SHE­ WRIGHT All FIELDS LANI SU­ FROM A SUIVIY PERFORMED IN 1=11R STRUCTURAL FILL OR ROAD SURFACE. .1VERF.N.FF.(TVP.) 1. ALL OUTSIDE SLOPE EMBANIOMENTS SHOWN ARE 2H IV UNLESS OTHERNBE NOT- 6LOCATION 11 ALL =� AL STEILD SARI TO FIRDOORTINUFF—H THE 1. ISO E=�ENCSOI CICIOL DI ARE TO BE INSTALLED PRIOR TO NN STUREAN FACT BE 12 THE DESIGNIENGINEERING VABRK SHOWN ON THIS SHEET IS EACLUBBIEUI BASED INDIDAILL111-11RAL FILL BLUFFS IF 21:11 MUST BE ENHANCED BY FLATTE.N. THE F"L'LOPF_.A'H'V SLOPE COULD BE CONDUCTED N ADD 1ION. INSTALLATION OF A T' D"N ALONE THE SLOPE TIE SHALL BE DESIBE NED AND INSTALLED WITH E 7 HER OPTION TO IMPROVE LOND TEAU SLOPE EBA EXISTING EXISTING CELL NO. 3B GRAPHIC GCaLE IN FEET PROPOSER GIRAIRAOE5TRUCTURES_-- A' /N PIPE ND. I GIB I LENGTH SLOPE I MATERIAL bTNE� EXISTING T100 �' g 100% TOP or so L L HER GRAD nc Taau CELL N0.)4 { PROPOSED FLARED FND SECTIONS CONSTRUCTION OF CELL NO. 6B \ ELE E E . TT 1C2B.90 n 1amL0 / FOOTHILLS REGIONAL LANDFILL REPUBLIC SERVICES OF NORTH CAROLINA LLC CALDWELL COUNTY BOARD OF COMMISSIONERS 1�P�R®k left REPUBLIC ei'eTioiii's�exT TnmAx - PSHEETTwsE 3 OF'oTT 7 � BUNNELL LAMM©N5 ENGINEERING RECORD OF DAILY OBSERVATIONS FOOTHILLS REGIONAL LANDFILL CONSTRUCTION QUALITY ASSURANCE - CONSTRUCTION OF CELL NO. 6B CADWELL COUNTY, NORTH CAROLINA BUNNELL-LAMMONS ENGINEERING, INC. PROJECT NO. J23-1235-109 HHNT-INC, PROJECT NUMBER 6703-1142-01 CLIENT: Republic Services of North Carolina, LLC DATE: 05/19/2023 Project Day Number 40 ARRIVAL TIME: 7:00 Notice to Proceed Date: 04/10/2023 DEPARTURE TIME: 18:00 WORK HOURS: 11.00 VISITORS: NAME REPRESENTING ONSITE BLE PERSONNEL: Stephen Mitchell WEATHER: ❑SUNNY ❑RAIN TEMPERATURE ❑PTLYCLOUDY ❑WINDY MORNING LOW: 62 °F ❑ CLOUDY DAYTIME HIGH: 85 °F SITE ACTIVITIES ❑✓ SITE PREPARATION ❑ GEOSYNTHETICS INSTALLATION ✓❑ OTHER ❑ STRUCTURAL FILL ❑ LEACHATE COLLECTION SYSTEM ❑ COMPACTED SOIL LINER ❑ DRAINAGE LAYER CONTRACTOR ACTIVITIES: Earnhardt Grading, Inc. 1) Earnhardt placed rocky fill in area to the east of Cell No. 613 and in the toe key area. Rocky fill material was placed using CAT 740B off road haul trucks and spread using CAT D8T and CAT D5K bulldozers before being compacted using CAT padfoot compactor. 2)Carolina Drilling blasted section of project area at approx 2:00 pm. BLE measured water levels in MW-11 before and after the blast. Pre blast water level was measured to be 83.60 feet at 11:30 am, and post blast water level was measured to be 83.58 feet at 3:00 pm. CONSTRUCTION ISSUES: N/A TECHNICIAN ACTIVITIES: 1) Observed and documented contractor activities mentioned above. RECORD REVIEWED & APPROVED BY: Jonathan P. Usher, P.E. Signature 60G4 Ponders Court, Greenville, SC 29615 ',864,288.1265--664.288.4430 M infCLnhlecorp.rom BLECORMOM Rev 2,0 j, �/� PEREOHEAR EA � I iilV\ Al EAF, NrR�PL [ - I � � I \ I 2�, CELL NO. 6B IM z pproximate area of rocky fill placement rea of blasting Ire`\,`�'��������JJ PL coSELF LF N. ` EXISTING IHTOPRO/Em AREA, EL ooREArER CELL NO. 5A yao« / � sHALLEEz�NININ�Nallo,o x ,366z3� ylaa is mT) \ $ !� �EXISTING I CELL NO. 3C _ EXISTING 1 , -,� CELL NO 6A E=ROAD ` OROSEDDTURNN ^� yry) ^ $ ouno unnuRN\ J CELL TINNO. 3B EXISTING EW RPE ND SIZE LBgIX SLOPE Wresa EXISTING noO Er +ous cPP CELL /NO.4 PROPOSE[) FLSECTIONS NON NO. ELEV.— NO. N0. ELEV. EXISTING CELL NO. 8A �iw-sa REPUBLIC BENCHMARKS Bill NO. NORTHING EASTING ELEV. DESCRIPTION REBAR GRAPHIC SCALE IN FEET fqiIS,,} e A11E d" RLF REPUBLIC SERVICES OFNORTH CAROLINA, LLC CALDWELL COUNTY BOARD OF COMMISSIONERS nl [IUEELF.tNC >rzo na FSHEET�sE 13 EOF,On �u APPENDIX C: SEISMIC ANALYSIS September 8, 2023 Mr. Jason Tutterow Carolina Drilling & Blasting 326 Railroad Street Mocksville, North Carolina 27028 Re: Foothills Landfill — Lenoir, North Carolina Dear Mr. Tutterow: i / VibraTech VibraTechinc.com 377 Rubin Center Drive Suite 114 Fort Mill, SC 29708 Phone 803.548.3066 Fax 803.548.3083 This report summarizes the vibration activity detected by the continuous recording seismographs in the near vicinity of the Foothills Landfill project in Lenoir, North Carolina, during the time period May 10-19, 2023. The report compares the vibration levels detected by the continuous recording seismographs to NFPA 495, Explosive Materials Code, which outlines vibration limits that are safe for typical residential structures. The maximum ground vibration of the recorded peak velocity for blasts during this time period occurred on May 12, 2023, at 12:10 PM. The maximum was 0.771 inches per second (ips) with a corresponding frequency of 45.5 hertz (Hz), which was below the established criteria for ground vibration at blasting operations as recommended by the National Fire Protection Association (NFPA) (NFPA 495 11.2.1: 2018 Edition). The maximum value for the recorded air overpressure for blasts during this time period occurred on May 10, 2023, at 2:30 PM. The maximum was 140 dBL (0.029 psi), which was 224% of the 133 dBL criteria for air overpressure as recommended by the National Fire Protection Association (NFPA) (NFPA 495 11.3: 2018 Edition). The invoice for this service will follow under separate cover. Should you have any questions concerning this report, please do not hesitate to contact our office. Respectfully submitted, VIBRA-TECH,INC.� John Midgley Area Project Manager AC/jj Enclosures 6t,WL 5a Andrew Coil Area Manager Vibra-Tech, Inc., shall not be liable for any claims of tangible property damage where such damage is not solely, directly, and physically caused by Vibra-Tech, Inc. Additionally, Vibra-Tech, Inc., shall not be liable, in whole or in part, for any claims of tangible property damage brought by or on behalf of third -party claimants. VIBRA-TECH EVENT SUMMARY Carolina Drilling & Blasting Foothills Landfill May 10-19, 2023 CONTINUOUS SEISMIC RECORDER EVENT DATE TIME SEISMOGRAPH N0. LOCATION AIR dBL TRAN PPV FREQ VERT PPV FREQ LONG PPV FREQ TRIGGER IPS # 5/10/2023 2:30 PM 10953 TOP OF BERM 140 0.344 33.3 0.579 55.6 0.486 38.5 0.021 ** 5/10/2023 2:30 PM 9795 WELL ACCESS ROAD N/T <0.050 N/A <0.050 N/A <0.050 N/A 0.050 ** 5/10/2023 2:30 PM 7251 BETW SCALEHSE STORAGE T N/T <0.050 N/A <0.050 N/A <0.050 N/A 0.050 & 5/12/2023 12:10 PM 10953 TOP OF BERM 136 0.476 27.8 0.771 45.5 0.456 31.2 0.021 ** 5/12/2023 12:10 PM 9795 WELL ACCESS ROAD N/T <0.050 N/A <0.050 N/A <0.050 N/A 0.050 ** 5/12/2023 12:10 PM 7251 BETW SCALEHSE STORAGE T N/T <0.050 N/A <0.050 N/A <0.050 N/A 0.050 5/16/2023 2:21 PM 10953 TOP OF BERM 128 0.276 31.2 0.254 38.5 0.269 35.7 0.021 ** 5/16/2023 2:21 PM 9795 WELL ACCESS ROAD N/T <0.050 N/A <0.050 N/A <0.050 N/A 0.050 ** 5/16/2023 2:21 PM 7251 BETW SCALEHSE STORAGE T N/T <0.050 N/A <0.050 N/A <0.050 N/A 0.050 5/18/2023 12:02 PM 10953 TOP OF BERM 123 0.206 33.3 0.134 45.5 0.169 33.3 0.021 ** 5/18/2023 12:02 PM 9795 WELL ACCESS ROAD N/T <0.050 N/A <0.050 N/A <0.050 N/A 0.050 ** 5/18/2023 12:02 PM 7251 BETW SCALEHSE STORAGE T N/T <0.050 N/A <0.050 N/A <0.050 N/A 0.050 5/19/2023 2:01 PM 10953 TOP OF BERM 124 0.141 27.8 0.106 38.5 0.104 33.3 0.021 ** 5/19/2023 2:01 PM 9795 WELL ACCESS ROAD N/T <0.050 N/A <0.050 N/A <0.050 N/A 0.050 ** 5/19/2023 2:01 PM L7251 BETW SCALEHSE STORAGE T N/T <0.050 N/A <0.050 N/A <0.050 N/A 0.050 & GREATEST PEAK PARTICLE VELOCITY (IPS) READING # GREATEST PEAK AIR OVERPRESSURE (dBL) READING ** SEISMIC ACTIVITY NOT SUFFICIENT ENOUGH TO TRIGGER THE SEISMOGRAPH N/T UNIT NOT SET TO TRIGGER ON AIR L T V S Seismic Analysis Combined OSMIVelocity Waveform Analysis Job ID: j-GEO-46348 OSM Safe Blasting Levels Serial Number: 10953 SSN: 10953 Event: 14 Event Number: 14 Longitudinal • Transverse A Vertical ■ Event Time: 05/10/2023 14:30:15 UTC-04:00 10 Recording Time: 5.0 s Prod u ct/Fi rmware: OC-6.20 Client: CAROLINA DRILLING Operation: FOOTHILLS LANDFILL Location: TOP OF BERM Distance: 0 ft Operator: VIBRA-TECH IPC 1 Comment: Seismic Trigger: 0.021 in/s Sound Trigger: OFF Additional Info: Data truncated see org > N35 55 12.6,W81 35 38.1 0- Summary Data 0.1 L T V PPV (inls): 0.486 0.344 0.579 FREQ (Hz): 38.5 33.3 55.6 TIME (s): 0.857 0.771 0.852 PD (.001"): 2.61 1.52 1.73 PPA (g): 0.376 0.259 0.628 Peak Air Pressure: 140 dB (2.81e-02 psi) @ 12.8 Hz, 0.748 s 0.01 1 10 100 Shaketable Calibrated Frequency (Hz) On: 04/11/2023 By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 Louisville, KY 40203 U.S.A. Waveform Graph Scale Time Scale: OAS Seismic Scale: +/- 0.868 in/s Velocity Waveform Sound Scale: +/- 0.0422 psi SSN: 10953 Event: 14 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Time (s) /// V i bra Tec h Generated September 7, 2023 • Type: pd02 • Job: j-GEO-46348 • SSN: 10953 • Event: 14 • GSDS v2023.8.31 Vibra-Tech Seismic Analysis Stop Event Report Serial No: 9795 v6.19 Begin Date: 05/10/2023 07:00:52 (UTC-4) Client: CAROLINA DRILLING End Date: 05/10/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 3 (49-51) Location: WELL ACCESS ROAD Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 8.3 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46320 Louisville, KY 40299 U.S.A. N35 55 9.6,W81 35 35.8 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T v S Cal Test Results: Longitudinal: Pass Transverse: Pass Vertical: Pass Sound: Pass Printed: September 07, 2023 File: 242_9795_2023-05-10_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57) Vibra-Tech Seismic Analysis Stop Event Report Serial No: 7251 v6.19 Begin Date: 05/10/2023 07:00:55 (UTC-4) Client: CAROLINA DRILLING End Date: 05/10/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 2 (71-72) Location: BETW SCALEHSE STORAGE T Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 8.1 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46310 Louisville, KY 40299 U.S.A. N35 54 56.1,W81 35 42.3 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T v s Cal Test Results: Longitudinal: Pass Transverse: Pass Vertical: Pass Sound: Pass Printed: September 07, 2023 File: 242_7251_2023-05-10_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57) L T V S Seismic Analysis Combined OSMIVelocity Waveform Analysis Job ID: j-GEO-46348 OSM Safe Blasting Levels Serial Number: 10953 SSN: 10953 Event: 34 Event Number: 34 Longitudinal • Transverse - Vertical ■ Event Time: 05/12/2023 12:10:47 UTC-04:00 10 Recording Time: 5.0 s Prod u ct/Fi rmware: OC-6.20 Client: CAROLINA DRILLING Operation: FOOTHILLS LANDFILL Location: TOP OF BERM Distance: 0 ft Operator: VIBRA-TECH IPC 1 Comment: Seismic Trigger: 0.021 in/s Sound Trigger: OFF Additional Info: N35 55 12.6,W81 35 38.1 a a Summary Data L T V 0.1 PPV (in/s): 0.456 0.476 0.771 FREQ (Hz): 31.2 27.8 45.5 TIME (s): 0.742 0.989 0.880 PD (.001"): 2.20 2.98 3.26 PPA (g): 0.298 0.304 0.654 Peak Air Pressure: 136 dB (1.94e-02 psi) @ 3.1 Hz, 0.987 s 0.01 Olt • Iu I} `rL • • • • r - - •• NO ■ •may • •• wrww• u w • Shaketable Calibrated 1 10 100 On: 04/11/2023 Frequency (Hz) By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 Louisville, KY 40203 U.S.A. Waveform Graph Scale Time Scale: OAS Seismic Scale: +/- 1.157 in/s Velocity Waveform Sound Scale: +/- 0.0291 psi SSN: 10953 Event: 34 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Time (s) /// VibraTech Generated September 7, 2023 • Type: pd02 • Job: j-GEO-46348 • SSN: 10953 • Event: 34 • GSDS v2023.8.31 Vibra-Tech Seismic Analysis Stop Event Report Serial No: 9795 v6.19 Begin Date: 05/12/2023 07:00:52 (UTC-4) Client: CAROLINA DRILLING End Date: 05/12/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 7 (52-58) Location: WELL ACCESS ROAD Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 8.1 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46320 Louisville, KY 40299 U.S.A. N35 55 9.6,W81 35 35.8 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T v S Cal Test Results: Longitudinal: Pass Transverse: Pass Vertical: Pass Sound: Pass Printed: September 07, 2023 File: 242_9795_2023-05-12_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57) Vibra-Tech Seismic Analysis Stop Event Report Serial No: 7251 v6.19 Begin Date: 05/12/2023 07:00:54 (UTC-4) Client: CAROLINA DRILLING End Date: 05/12/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 0 (73-72) Location: BETW SCALEHSE STORAGE T Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 8.1 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46310 Louisville, KY 40299 U.S.A. N35 54 56.1,W81 35 42.3 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T v S Cal Test Results: Longitudinal: Pass Transverse: Pass Vertical: Pass Sound: Pass Printed: September 07, 2023 File: 242_7251_2023-05-12_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57) L T V S Seismic Analysis Combined OSMIVelocity Waveform Analysis Job ID: j-GEO-46348 OSM Safe Blasting Levels Serial Number: 10953 SSN: 10953 Event: 37 Event Number: 37 Longitudinal • Transverse - Vertical ■ Event Time: 05/16/2023 14:21:13 UTC-04:00 10 Recording Time: 5.0 s Prod u ct/Fi rmware: OC-6.20 Client: CAROLINA DRILLING Operation: FOOTHILLS LANDFILL Location: TOP OF BERM Distance: 0 ft Operator: VIBRA-TECH IPC 1 Comment: Seismic Trigger: 0.021 in/s Sound Trigger: OFF Additional Info: N35 55 12.6,W81 35 38.1 a a Summary Data L T V 0.1 PPV (in/s): 0.269 0.276 0.254 FREQ (Hz): 35.7 31.2 38.5 TIME (s): 1.373 1.262 1.348 PD (.001"): 1.52 1.41 1.03 PPA (g): 0.162 0.194 0.194 Peak Air Pressure: 128 dB (7.03e-03 psi) @ 5.3 Hz, 1.421 s 0.01 Shaketable Calibrated 1 10 100 On: 04/11/2023 Frequency (Hz) By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 Louisville, KY 40203 U.S.A. Waveform Graph Scale Time Scale: OAS Seismic Scale: +/- 0.414 in/s Velocity Waveform Sound Scale: +/- 0.0105 psi SSN: 10953 Event: 37 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Time (s) /// VibraTech Generated September 7, 2023 • Type: pd02 • Job: j-GEO-46348 • SSN: 10953 • Event: 37 • GSDS v2023.8.31 Vibra-Tech Seismic Analysis Stop Event Report Serial No: 9795 v6.19 Begin Date: 05/16/2023 07:00:52 (UTC-4) Client: CAROLINA DRILLING End Date: 05/16/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 3 (62-64) Location: WELL ACCESS ROAD Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 7.9 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46320 Louisville, KY 40299 U.S.A. N35 55 9.6,W81 35 35.8 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T v s Cal Test Results: Longitudinal: Pass Transverse: Pass Vertical: Pass Sound: Pass Printed: September 07, 2023 File: 242_9795_2023-05-16_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57) Vibra-Tech Seismic Analysis Stop Event Report Serial No: 7251 v6.19 Begin Date: 05/16/2023 07:00:54 (UTC-4) Client: CAROLINA DRILLING End Date: 05/16/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 0 (73-72) Location: BETW SCALEHSE STORAGE T Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 8.3 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46310 Louisville, KY 40299 U.S.A. N35 54 56.1,W81 35 42.3 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T v S Cal Test Results: Longitudinal: Pass Transverse: Pass Vertical: Pass Sound: Pass Printed: September 07, 2023 File: 242_7251_2023-05-16_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57) L T V S Seismic Analysis Combined OSMIVelocity Waveform Analysis Job ID: j-GEO-46348 OSM Safe Blasting Levels Serial Number: 10953 SSN: 10953 Event: 38 Event Number: 38 Longitudinal • Transverse A Vertical ■ Event Time: 05/18/2023 12:02:48 UTC-04:00 10 Recording Time: 5.0 s Prod u ct/Fi rmware: OC-6.20 Client: CAROLINA DRILLING Operation: FOOTHILLS LANDFILL Location: TOP OF BERM Distance: 0 ft Operator: VIBRA-TECH IPC 1 Comment: Seismic Trigger: 0.021 in/s Sound Trigger: OFF Additional Info: N35 55 12.6,W81 35 38.1 a a Summary Data L T V 0.1 PPV (in/s): 0.169 0.206 0.134 FREQ (Hz): 33.3 33.3 45.5 TIME (s): 0.924 0.858 0.830 PD (.001"): 0.85 1.31 0.66 PPA (g): 0.084 0.117 0.123 Peak Air Pressure: 123 dB (4.22e-03 psi) @ 18.5 Hz, 1.460 s 0.01 � :I Shaketable Calibrated 1 10 100 On: 04/11/2023 Frequency (Hz) By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 Louisville, KY 40203 U.S.A. Waveform Graph Scale Time Scale: OAS Seismic Scale: +/- 0.309 in/s Velocity Waveform Sound Scale: +/- 0.0063 psi SSN: 10953 Event: 38 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Time (s) /// VibraTech Generated September 7, 2023 • Type: pd02 • Job: j-GEO-46348 • SSN: 10953 • Event: 38 • GSDS v2023.8.31 Vibra-Tech Seismic Analysis Stop Event Report Serial No: 9795 v6.19 Begin Date: 05/18/2023 07:00:52 (UTC-4) Client: CAROLINA DRILLING End Date: 05/18/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 2 (68-69) Location: WELL ACCESS ROAD Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 8 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46320 Louisville, KY 40299 U.S.A. N35 55 9.6,W81 35 35.8 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T v s Cal Test Results: Longitudinal: Pass Transverse: Pass Vertical: Pass Sound: Pass Printed: September 07, 2023 File: 242_9795_2023-05-18_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57) Vibra-Tech Seismic Analysis Stop Event Report Serial No: 7251 v6.19 Begin Date: 05/18/2023 07:00:54 (UTC-4) Client: CAROLINA DRILLING End Date: 05/18/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 2 (73-74) Location: BETW SCALEHSE STORAGE T Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 8.3 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46310 Louisville, KY 40299 U.S.A. N35 54 56.1,W81 35 42.3 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T v s Cal Test Results: Longitudinal: Pass Transverse: Pass Vertical: Pass Sound: Pass Printed: September 07, 2023 File: 242_7251_2023-05-18_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57) Seismic Analysis Combined OSMIVelocity Waveform Analysis Job ID: j-GEO-46348 OSM Safe Blasting Levels Serial Number: 10953 SSN: 10953 Event: 40 Event Number: 40 Longitudinal • Transverse A Vertical ■ Event Time: 05/19/2023 14:01:16 UTC-04:00 10 Recording Time: 5.0 s Prod uct/Fi rmware: OC-6.20 Client: CAROLINA DRILLING Operation: FOOTHILLS LANDFILL Location: TOP OF BERM Distance: 0 ft Operator: VIBRA-TECH IPC 1 Comment: Seismic Trigger: 0.021 in/s Sound Trigger: OFF Additional Info: N35 55 12.6,W81 35 38.1 > a a Summary Data L T V 0.1 PPV (inls): 0.104 0.141 0.106 FREQ (Hz): 33.3 27.8 38.5 TIME (s): 0.808 0.766 0.663 PD (.001"): 0.61 0.87 0.41 PPA (g): 0.058 0.071 0.065 Peak Air Pressure: 124 dB (4.61e-03 psi) @ 4.6 Hz, 0.988 s 0.01 7F Ldh J L A�■��'� "A A - • .■ ■■ A.A■ M , ■ ■ ■ ••■ r Shaketable Calibrated 1 10 100 On: 04/11/2023 Frequency (Hz) By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 Louisville, KY 40203 U.S.A. Waveform Graph Scale Time Scale: 0.1 s Seismic Scale: +/- 0.212 in/s Velocity Waveform Sound Scale: +/- 0.0069 psi SSN: 10953 Event: 40 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 L T V M 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Time (s) /f/ VibraTech Generated September 7, 2023 • Type: pd02 • Job: j-GEO-46348 • SSN: 10953 • Event: 40 • GSDS v2023.8.31 Vibra-Tech Seismic Analysis Stop Event Report Serial No: 9795 v6.19 Begin Date: 05/19/2023 07:00:53 (UTC-4) Client: CAROLINA DRILLING End Date: 05/19/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 3 (70-72) Location: WELL ACCESS ROAD Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 8.2 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46320 Louisville, KY 40299 U.S.A. N35 55 9.6,W81 35 35.8 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T v S Cal Test Results: Longitudinal: Pass Transverse: Pass Vertical: Pass Sound: Pass Printed: September 07, 2023 File: 242_9795_2023-05-19_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57) Vibra-Tech Seismic Analysis Stop Event Report Serial No: 7251 v6.19 Begin Date: 05/19/2023 07:00:54 (UTC-4) Client: CAROLINA DRILLING End Date: 05/19/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 0 (75-74) Location: BETW SCALEHSE STORAGE T Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 8.3 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46310 Louisville, KY 40299 U.S.A. N35 54 56.1,W81 35 42.3 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T v s Cal Test Results: Longitudinal: Pass Transverse: Pass Vertical: Pass Sound: Pass Printed: September 07, 2023 File: 242_7251_2023-05-19_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57) Matt Cheek From: Jason Tutterow <reesecrushing@yahoo.com> Sent: Thursday, May 11, 2023 2:47 PM To: Chris Rowe Subject: Fw: Foothills Landfill 5-10-23 Attachments: Foothills Landfill 5-10-23.pdf Jason Tutterow Office (336)-751-2961 Mobile (336)-607-4478J _Js 3Fs$ida� 9i'4c.P�1 ra: !`tiil y @nf, inc. 326 Railroad St. Mocksville, NC 27028 ----- Forwarded Message ----- From: Carolinas Office <carolinas@vibratechinc.com> To: Tutterow, Jason <reesecrushing@yahoo.com>; Derek Wark <derekwark67@gmail. com> Cc: Jay Midgley <jaym@vibratechinc.com> Sent: Thursday, May 11, 2023 at 01:44:54 PM EDT Subject: Foothills Landfill 5-10-23 Javy checked out the seismograph and solar panel that were hit by something after the blast yesterday. It was not damaged. The data from yesterday's blast is attached. The non -blast data points from the strike after the blast have been removed, so the maximum PPV of the blast is now apparent. It was 0.579 in/s. Please let us know if you have any questions. Janan Jones Senior Office Administrator 803-548-3066 Office Phone 191 377 Rubin Center Drive, Suite 114 Fort Mill, SC 29708 k,vkjvvv.vibraterhinc.corn The above email is for the intended recipient only and may contain information that is privileged, confidential or otherwise protected from disclosure. If you are not the intended recipient, please advise the sender immediately. 1 L T V S Seismic Analysis Velocity Waveform Analysis Job ID: i-GEO-46348 USBM Safe Blasting Levels Serial Number: 10953 SSN: 10953 Event: 14 Event Number: 14 Longitudinal • Transverse A Vertical ■ Event Time: 05/10/2023 14:30:15 UTC-04:00 10 Recording Time: 5.0 s Prod uct/Fi rmware: OC-6.20 .... .. .... _.. Client: CAROLINA DRILLING Operation: FOOTHILLS LANDFILL Location: TOP OF BERM Distance: 0 ft Operator: VIBRA-TECH IPC 1 Comment: Seismic Trigger: 0.021 in/s ^n .. _ ■. - - - - - - • ° oil Sound Trigger: OFF Additional Info: Data truncated see or 9 a N35 55 12.6,W8135 38.1>< -qv=i�', a 4n'4O.. Summary Data 0.1 r L T V fit• PPV (in/s): 0.486 0.344 0.579 • nrpia• FREQ (Hz): 38.5 33.3 55.6 TIME (s): 0.857 0.771 0.852 • ° ®: ® : 1 PD (.001" ): 2.61 1.52 1.73 A AA ■ PPA (g): 0.376 0.259 0.628 ® a 0.01 Peak Air Pressure: 2.81e-02 psi (140 dB) @ 12.8 Hz, 0.748 s 1 10 Frequency (Hz) Shaketable Calibrated Zero Crossing Half -Wave Frequency Analysis On: 04/10/2023 By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 Louisville, KY 40203 U.S.A. Waveform Graph Scale Time Scale: 0.1 s 100 Seismic Scale: +/- 0.868 in/s Velocity Waveform Sound Scale: +/- 0.0422 psi SSN: 10953 Event: 14 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Time (s) Vibra-Tech Seismic Analysis Stop Event Report Serial No: 7251 v6.19 Begin Date: 05/10/2023 07:00:55 (UTC-4) Client: CAROLINA DRILLING End Date: 05/10/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 2 (71-72) Location: BETW SCALEHSE STORAGE T Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 8.1 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46310 Louisville, KY 40299 U.S.A. N35 54 56.1,W81 35 42.3 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T V s Printed: May 11, 2023 File: 242_7251_2023-05-10_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57) Vibra-Tech Seismic Analysis Stop Event Report Serial No: 9795 v6.19 Begin Date: 05/10/2023 07:00:52 (UTC-4) Client: CAROLINA DRILLING End Date: 05/10/2023 21:00:00 (UTC-4) Operation: FOOTHILLS LANDFILL Events over Trigger: 3 (49-51) Location: WELL ACCESS ROAD Record Time: 5.0 s Distance: Seismic Trigger: 0.050 in/s Operator: VIBRA-TECH IPC Sound Trigger: N/A Comment: Battery Level: 8.3 Shaketable Calibrated: 04/05/2023 Additional Info: By: Vibra-Tech, Inc. 2700 Holloway Road - Suite 113 j-GEO-46320 Louisville, KY 40299 U.S.A. N35 55 9.6,W81 35 35.8 TEL: 502.240.9900 FAX: 502.240.9902 Dynamic Calibration Graph: L T V s Printed: May 11, 2023 File: 242_9795_2023-05-10_210000.g3k (GeoSonics Inc. AnalysisNET v8.1.57)