Loading...
HomeMy WebLinkAbout25087_Hammond Center_DM_20230801DECISION MEMORANDUM DATE: August 1, 2023 FROM: Shristi R. Shrestha TO: BF Assessment File RE: Hammond Center Drive 100, 101, and 120 Hammond Center Drive Raleigh, Wake County BF # 25087-21-092 Based on the following information, it has been determined that the above referenced site, whose intended use is for no uses other than high -density rental residential, office, retail, recreational, parking uses, and subject to DEQ prior written approval, other commercial uses, can be made suitable for such uses. Introduction: The Brownfields Property Application (BPA) was submitted on October 15, 2021, under the former address of 100 Knowles Street, Raleigh. The Prospective Developer (PD) is Maple Multi -Family Development Land SE, L.P., a limited partnership with its principal office located at 4509 Creedmoor Rd, Suite 308, Raleigh, NC 27612. The Vice President for the PD is Robert H. Brooks, and the contact person is Mark Mathews. The Brownfields Property is comprised of three parcels totaling 35.77 acres: 100 Hammonds Center (PIN 1702772682), 10.05 acres, 101 Hammonds Center Drive (PIN 1702668490), 10.03 acres and 120 Hammonds Center Drive (PIN 1702677491),15.60 acres. The current property owner is CH-AFH I/Raleigh downtown south LLC located at 4509 Creedmoor Rd Suite 308, Raleigh NC 27612. Redevelopment Plans: The PD plans to redevelop the property into a multi -family apartment community. Final redevelopment plans are complete and were submitted in June 2023. The apartment count will not exceed 350. The application states that the apartment community will include generous amount of green space for recreational use of the residents. Due to the detection of trichloroethene (TCE) in two of the exterior soil gas samples in excess of its Residential Vapor Intrusion Screening Level (VISL) under the future footprint of two of the three planned buildings and near or within the planned utility corridor, DEQ has highly recommended that the PD install a Vapor Intrusion Mitigation System (VIMS) in accordance with our VIMS design checklist. The PD submitted a VIMS design on March 6, 2023. Hammond Center Drive/25087-21-092/20230801 Site History: The Brownfields Property was agricultural, wooded and undeveloped land in 1938. From 1949 to 1968, a pond named Parker Pond was located on the southern portion of the Brownfields Property. A structure was also present along the semi -circular roadway on the along the northwestern boundary in the early 1970s. The pond on the southern portion appeared to be drained or reduced in size by 1973, with only a small pond along the southwestern boundary. There is no indication that the Brownfields Property itself was ever developed with structures, although recent observations indicate dumping of trash and household debris at the end of Hammond Center Drive A stream, Wildcat Branch, runs through the Brownfields Property near the eastern boundary. Two monitoring wells were installed in 2009 on the Brownfields Property in the northeastern area, west of Wildcat Branch. The monitoring wells were installed related to contamination identified from the Raleigh Metals property located east of Hammond Road. Raleigh Metal Recycling, or its predecessors, have been located to the east of the property since the early 1950s, prior to the development of Hammond Road. In the site vicinity, commercial and industrial properties are located to the north, such as International Paper (now Evergreen Packaging) and Winn Dixie (now UPS) were developed adjacent to the northwest and farther north in the mid- 1950s and expanded in the 1980s and 1990s. The residential neighborhood to the west has been present since the mid-1960s. Potential Receptors: Potential receptors are construction workers, on -site workers, future residents, and trespassers. Contaminated Media: DEQ has evaluated data collected from the following media at the Brownfields Property: soil, groundwater and exterior soil gas. DEQ relies on the following data to base its conclusions regarding the subject property and its suitability for its intended reuse. Please see the Brownfield Agreement's Exhibit 2 for specific sample locations, dates, and contaminants of concern (COCs). Risk Calculations: Risk calculations were performed using the January 2023 DEQ Risk Calculator https:Hdeg.nc. goy/permits-rules/risk-based-remediation/risk-evaluation-resources. For the purposes of looking at the site spatially, the site was evaluated as a whole. The risk calculations indicated the following based on available data, including the following media: soil, groundwater and exterior soil gas samples. 2 Hammond Center Drive/25087-21-092/20230801 Risk for Individual Pathways M Version Date: January 2023 Basis: November 2022 EPA RSL Table Site ID: 25087-21-092 Exposure Unit ID: Site wide (Soil, GW & Soil as) DIRECT CONTACT SOIL AND WATER CALCULATORS Receptor Pathway Carciinnsogenic Hazard Index Ri sk exceeded? Resident Soil 7.0E-06 8.0E-02 NO Groundwater Use* 1.3E-04 2.6E+00 YES Non -Residential Worker Soil 7.6E-07 5.7E-03 NO Groundwater Use* 2.8E-05 5.2E-01 NO Construction Worker Soil 4.8E-07 5.7E-02 NO Recreator/Trespasser Soil 3.9E-06 4.4E-02 NO Surface Water* NC NC NC VAPOR INTRUSION CALCULATORS Receptor Pathway Carcinogenic Risk Hazard Index Ri sk exceeded? Resident Groundwater to Indoor Air 2.5E-06 3.8E-01 NO Soil Gas to Indoor Air 1.0E-05 8.8E-01 NO Indoor Air NC NC NC Non -Residential Worker Groundwater to Indoor Air 4.8E-07 9.1E-02 NO Soil Gas to Indoor Air 7.3E-07 7.0E-02 NO Indoor Air NC NC NC The risk calculator output shows that the noncancer hazard index (HI) for resident direct groundwater use exceeds the regulatory threshold of 1, and the acceptable cancer risk range of 1.0E-04. The soil gas to indoor air calculated HI is 0.88; although this does not exceed the threshold HI of 1, this value is based on exterior soil gas samples only. Further because TCE was detected in excess of its Residential VISL in exterior soil gas samples near planned utility corridors, we are concerned, as we have seen at other sites, that although the calculated soil gas to indoor air risk value at 0.88 is less than 1.0, that the construction of the buildings on the Brownfields Property, especially the two southern buildings will change site conditions creating areas in which TCE migration along preferential pathways or accumulation of vapors in sub -slab areas may pose a risk of vapor intrusion into the living space. Therefore, we have recommended that a vapor intrusion mitigation system (VIMS) be designed and installed for these buildings. Soil The soil samples were collected with direct push techniques using disposable soil liners placed within the dual tube soil sampler. The samples depth range was from ground surface to depth ranging from 10-25 ft bgs. No soil import or export has been done to or from the Brownfields Property at this time; any future import or export will be done under an approved Environmental Management Plan (EMP). Only arsenic and hexavalent chromium concentrations in site soils exceeded their respective January 2023 North Carolina Department of Environmental Quality (NCDEQ) Inactive Hazardous Waste Site Branch (IHSB) Preliminary Soil Remediation Goals (PSRGs). However, calculated risk values indicate that compounds in soil at the Brownfields Property do not exceed the acceptable risk thresholds for any soil exposure scenario as noted in the risk output above. Hammond Center Drive/25087-21-092/20230801 Groundwater Based on the environmental assessment done at the Brownfields Property, the groundwater flow is anticipated to be towards the east to Wildcat Branch. The depth of groundwater encountered at the Brownfields Property was from 2.4 ft bgs to 6.7 ft bgs. Groundwater will not be used as a water supply for this site and a land use restriction will further prohibit its use. The hazard index was exceeded in resident groundwater use due to the presence of compounds like Arsenic, Cadmium, Naphthalene and Trichloroethylene. Surface Water Surface water was not sampled at the Brownfields property. Exterior Soil Gas Exterior soil gas samples were collected at the Brownfields Property without the Brownfields Program's input or approval prior to applying to the Program. During the Phase II assessment of the Brownfields Property exterior soil gas samples that were collected on October 16, 2021, were not collected in accordance with our VI assessment protocols. The final vacuums in the Summa canisters were below the recommended limit. Hence, the exterior soil gas samples were collected again in August 2022, and the results from the previous soil gas assessment were disregarded, and not used in the preparation of Exhibit 2 or the risk calculators. TCE and 1,3-butadiene were detected in exterior soil gas samples in excess of their respective Residential VISLs. There were several other contaminants detected, acetone, dichlorodifluoromethane (Freon 12), ethanol, and 4-ethyltoluene were also detected, but there are no established screening levels for these compounds. The main drivers of risk for the calculation of the soil gas to indoor air vapor intrusion risk scenario is the presence of primarily TCE in samples UCSV-Ul, located near a utility line, and UCSV-B 1, located under the future building footprint, at 39 and 38 µg/m3, respectively and 1,3-butadiene at 20 µg/main sample UCSV-U2. As discussed above, based on the toxicology of TCE, the fact that these detections were in exterior soil gas near planned utility corridors, there is uncertainty as to the impact that the construction of these residential structures may have on the potential for vapor intrusion into the buildings. Therefore, it is highly recommended that a VIMS system be placed under at least the two southern buildings on this Brownfields Property. and the samples UCSV- B 1 are located under two of the future building footprints. Vapor intrusion risk will be addressed through the VI land use restriction in the Brownfields Agreement. Indoor Air No buildings have been constructed as of yet; hence this is not applicable. 4 Hammond Center Drive/25087-21-092/20230801 Land Use Restrictions: The land use restrictions at the property will include the typical land use restrictions related to approved land uses, no physical redevelopment without an EMP, redevelopment reporting, restrictions on groundwater use, soil disturbance and fill/export of soil, final grade sampling, known contaminant uses, notices, access, deed, and land use restriction update provisions. Based on the site -specific data provided to the Brownfield Redevelopment Section, the site reuse is suitable for the site if the agreed upon land use restrictions in the BFA are abided by. PROPERTY MANAGEMENT ISSUES: The Brownfields Property is currently undeveloped. Construction was originally slated to being in April 2023, but has been delayed. A redevelopment plan was submitted on 6/27/2023. A VIMS system design system submittal was done by PD on March 6, 2023. VIMS design was approved, and the letter was sent out on 7/19/2023. Post -recordation issues are expected to include performance monitoring of the VIMS and final grade sampling. Hammond Center Drive/25087-21-092/20230801