Loading...
HomeMy WebLinkAboutSDTF3616_INSP_20230605NORTH CARnLINAD_E Q�� o.n.mm.m m c.w.mm.m.i a.i� FACILITY COMPLIANCE INSPECTION REPORT Division of Waste Management Solid Waste Section UNIT TYPE: Lined LCID YW Transfer Compost SLAS COUNTY: Gaston MSWLF PERMIT NO.: SDTF-36-16 Closed HHW White Incin T&P FIRM MSWLF goods FILE TYPE: COMPLIANCE CDLF Tire T&P/ Tire Industrial DEMO SDTF X Collection Monofill Landfill Date of Site Inspection: 6/5/2023 Date of Last Inspection: 1/26/2021 FACILITY NAME AND ADDRESS: WRE Earth Farms LLC DBA Stanley Environmental Solutions 131 Mariposa Road Stanley, NC 28164 GPS COORDINATES: N: 35.37209' E:-81.09669' FACILITY CONTACT INFORMATION: Name: Nate Wooten Address: PO Box 184, Stanley, NC 28164 Telephone: 704-263-8186 Email address: nwooten@wrenvironmental.com, nwooten@stanleyenviro.com PARTICIPANTS: Stephanie Williams, DWMSolid Waste Section Nate Wooten, Stanley Environmental Solutions STATUS OF PERMIT: Active EXPIRES: 312812024 PURPOSE OF SITE VISIT: Routine inspection STATUS OF PAST NOTED VIOLATIONS: N/A OBSERVED VIOLATIONS: 1) 15A NCAC 13B .0838(k): Proper signage was not posted on site at the time of inspection. Please note that access roads or paths crossing or leading to the facility shall be posted with "NO TRESPASSING' signs. The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit, or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules. Page 1 of 2 FACILITY COMPLIANCE INSPECTION REPORT D_E Q�� Division of Waste Management NORTH CAROLINA OepaN W Emironm l p ,ift Solid Waste Section ADDITIONAL COMMENTS 2) This facility consists of one above ground 12,000-gallon steel tank and two 20,000-gallon frac tanks for a total capacity of 52,000 gallons for the storage of domestic septage and grease septage. One of the frac tanks is not in use. 3) 15A NCAC 13B .0838(b): An all-weather access road is maintained. 4) 15A NCAC 13B .0838(c): No holes or cracks which may allow the escape of septage were noted. 5) 15A NCAC 13B .0838(e)(2) and 15A NCAC 13B .0838(g): No vector or odor issues were noted. 6) 15A NCAC 13B .0838(i): No vegetation was noted within 5 feet of the tank. 7) 15A NCAC 13B .0838(k): Proper signage was not posted on site at the time of inspection. Please note that access roads or paths crossing or leading to the facility shall be posted with "NO TRESPASSING" signs. 8) 15A NCAC 13B .0838(m): Setback requirements appear to have been met. Please contact me if you have any questions or concerns regarding this inspection report. U)4&� Phone: (919) 605-5576 St p ah nie Williams, Environmental Specialist II Division of Waste Management, NCDEQ Regional Representative Sent on: 6/15/2023 x Email Hand delivery US Mail Certified No. fI Page 2 of 2