Loading...
HomeMy WebLinkAbout7304_UpperPiedmontMSWLF_Phase4DesignHydrogeoReport_FID1810481_20230710 DESIGN HYDROGEOLOGIC REPORT – PHASE 4 (CELLS NO. 7-10) UPPER PIEDMONT REGIONAL MSW LANDFILL PERSON COUNTY, NORTH CAROLINA FACILITY PERMIT NUMBER 7304-MSWLF-1997 Prepared For: Republic Services of North Carolina, LLC 5111 Chin Page Road Durham, North Carolina 27703 BLE North Carolina Business Licenses C-284 & C-1538 BLE Project Number J21-1003-81 July 7, 2023 07/07/2023 July 7, 2023 Republic Services of North Carolina, LLC 5111 Chin Page Road Durham, North Carolina 27703 Attention: Mr. Matt Einsmann, P.E. Environmental Manager Subject: Design Hydrogeologic Report –Phase 4 (Cells No. 7-10) Upper Piedmont Regional MSW Landfill Person County, North Carolina Facility Permit Number 7304-MSWLF-1997 BLE Project Number J21-1003-81 BLE North Carolina Business Licenses C-284 & C-1538 Dear Mr. Einsmann: As authorized, Bunnell-Lammons Engineering, Inc. (BLE) has completed the Design Hydrogeologic Study for Cells No. 7-10 at the Upper Piedmont Regional MSW Landfill in Person County, North Carolina. This report addresses the relevant site application requirements as outlined in the North Carolina Rules for Solid Waste Management, 15A NCAC 13B .1623 (b). The attached report describes the work performed and presents the results obtained. We appreciate the opportunity to serve as your geological, hydrogeological, and geotechnical consultant on this project and look forward to continuing working with you at the Upper Piedmont Regional MSW Landfill. If you have any questions, please contact us at (864) 288-1265. Sincerely, BUNNELL LAMMONS ENGINEERING INC. Riley L. Blais, G.I.T. Tyler W. Moody, P.E. Staff Hydrogeologist Senior Geotechnical Engineer Licensed, North Carolina No. 42375 Timothy J. Daniel, P.G. Project Hydrogeologist Licensed, North Carolina No. 2653 cc: Mr. K. Matthew Cheek, P.E. – HHNT Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 i of iv TABLE OF CONTENTS 1.0 PROJECT INFORMATION ........................................................................................................ 1 2.0 FIELD INVESTIGATION ............................................................................................................ 2 2.1 Test Boring and Soil Sampling ..................................................................................................... 3 2.2 Groundwater Investigation ........................................................................................................... 3 2.3 Laboratory Testing ........................................................................................................................ 4 2.4 Fracture Trace Analysis ................................................................................................................ 4 2.5 Surface Geophysical Survey.......................................................................................................... 5 2.6 Field Reconnaissance ..................................................................................................................... 5 3.0 RESULTS OF INVESTIGATION ............................................................................................... 6 3.1 Regional Geology ........................................................................................................................... 6 3.2 Regional Hydrogeology ................................................................................................................. 7 3.3 Study Area Physiography and Topography ................................................................................ 7 3.4 Study Area Subsurface Conditions .............................................................................................. 7 3.4.1 Geologic Unit Description .................................................................................................... 8 3.4.1.1 Residual Soil ..................................................................................................................... 8 3.4.1.2 Partially Weathered Rock (PWR) ..................................................................................... 8 3.4.1.3 Fractured Bedrock ............................................................................................................ 8 3.4.2 Fracture Trace Analysis ...................................................................................................... 9 3.4.3 Surface Geophysical Survey .............................................................................................. 10 3.4.4 Laboratory Testing Results ................................................................................................ 10 3.5 Study Area Hydrogeology ........................................................................................................... 11 3.5.1 Piezometer Construction and Nomenclature .................................................................... 11 3.5.1.1 Residual Soil Piezometers ............................................................................................... 11 3.5.1.2 Partially Weathered Rock Piezometers ........................................................................... 12 3.5.1.3 Bedrock Piezometers and Groundwater Monitoring Wells ............................................ 12 3.5.2 Seasonal High Groundwater Elevations ........................................................................... 12 3.5.3 Estimated Long-Term Seasonal High Groundwater Elevations ...................................... 13 3.5.4 Groundwater Flow Direction ............................................................................................. 13 3.5.5 Man-made Influences to Groundwater Levels .................................................................. 13 3.5.6 Hydraulic Coefficients and Groundwater Flow Velocity ................................................. 14 3.5.6.1 Hydraulic Conductivity ................................................................................................... 14 3.5.6.2 Hydraulic Gradient ......................................................................................................... 14 3.5.6.3 Effective Porosity and Specific Yield .............................................................................. 15 3.5.6.4 Groundwater Flow Velocity ............................................................................................ 15 3.6 Summary of Geologic and Hydrogeologic Formation Properties ........................................... 15 3.7 Geotechnical Considerations ....................................................................................................... 15 3.7.1 Fault Areas ......................................................................................................................... 16 3.7.2 Seismic Impact Zones ........................................................................................................ 16 3.7.3 Unstable Areas ................................................................................................................... 16 3.7.4 Permeability of Potential On-Site Soils for Liner and Cover Construction ..................... 16 3.7.5 Earthwork Activities ........................................................................................................... 16 4.0 WATER QUALITY MONITORING PLAN ............................................................................ 18 4.1 Groundwater Monitoring Plan ................................................................................................... 18 4.1.1 Subsurface Considerations ................................................................................................ 18 Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 ii of iv 4.1.2 Relevant Point of Compliance ........................................................................................... 18 4.1.3 Monitoring Well Locations ................................................................................................ 18 4.1.4 Monitoring Well Depths and Screened Intervals .............................................................. 20 4.1.5 Spacing and Number of New Monitoring Wells ............................................................... 20 4.2 Surface Water Monitoring Plan ................................................................................................. 21 4.3 Water Quality Monitoring System ............................................................................................. 22 5.0 CONCLUSIONS .......................................................................................................................... 23 6.0 ANNOTATED BIBLIOGRAPHY ............................................................................................. 25 Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 iii of iv TABLES Table 1 Monitoring Well, Piezometer, and Boring Survey Information Table 2 Monitoring Well and Piezometer Construction Details Table 3 Groundwater Elevation Measurements & Depth to Groundwater Table 4 Summary of In Situ Hydraulic Testing – Slug Test Results Table 5 Summary of Laboratory Results - Split Spoon and Shelby Tube Samples Table 6 Summary of Laboratory Results - Remolded Bag Samples Table 7 Interstitial Groundwater Flow Velocity Calculations – Phase 4 Table 8 Summary of Hydrogeologic and Geologic Characteristics of Geologic Units – Phase 4 FIGURES Figure 1 Site Location Map Figure 2 Boring Location Plan Figure 3 Generalized Geologic Map of North Carolina Figure 4 Geologic Map of the Roxboro/ Virgilina Area Figure 5 Geologic Profiles: Cross-Sections A-A' and B-B' Figure 6 Top of Bedrock (Auger Refusal) Elevation Contour Map Figure 7 Geologic Map Figure 8 Water Table Elevation Contour Map – October 27, 2021 Figure 9 Composite Seasonal High Water Table Elevation Contour Map – February 2021 to February 2022 Figure 10 Estimation of Long-Term Seasonal High Water Table Elevation Contour Map APPENDICES Appendix A Drilling and Sampling Procedures Appendix B Soil and Rock Boring Records and Well Diagrams Appendix C Piezometer Installation Procedures Appendix D Survey Data Appendix E Precipitation Data Appendix F Slug Test Procedures and Results Appendix G Soil Laboratory Test Procedures Appendix H Soil Laboratory Test Results Appendix I Fracture Trace Analysis Data Appendix J Surface Geophysical Methods and Data Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 iv of iv REPORT CROSS-REFERENCE INDEX OF APPLICABLE NORTH CAROLINA STATE SOLID WASTE REGULATIONS 15A NCAC 13B .1623 (b) Design Hydrogeologic Report Requirements State Regulations Location in Report (b) (1) (A) Sections 3.5.2, 3.7.3; Table 2; Figures 5, 9 (b) (1) (B) Sections 3.4, 3.5; Tables 2, 3, 4, 5, 6, 7, 8; Figures 5, 6, 7, 8, 9, 10; Appendices B, E, F, I, J, K (b) (2) (A) From 15A NCAC 13B .1623(a) (a) (4) (A) Sections 2.1, 3.4.1; Appendices A, B (a) (4) (B) Sections 2.3, 3.4.4; Tables 5, 6, 8; Appendices G, H (a) (4) (C) Sections 3.4.1, 3.4.4; Tables 5, 6, 8; Appendices B, H (a) (4) (D) Sections 3.4; Tables 5, 6, 8; Figure 7; Appendix B (a) (4) (E) Sections 3.4.4, 3.5.6; Tables 4, 5, 6, 8; Appendices F, H (a) (5) Sections 2.4, 2.5, 3.4.2, 3.4.3; Appendix I, J (a) (6) Figure 5 (a) (7) (A) Table 3 (a) (7) (B) Section 3.5.2; Table 3; Appendix E (a) (7) (C) Section 3.5.3; Table 3; Figure 10; Appendix E (a) (7) (D) Sections 3.2, 3.5.2, 3.5.3, 3.5.5 (a) (8) Sections 3.5.4, 3.5.6; Tables 4, 7; Figures 5, 8; Appendix F (a) (9) Figures 8, 9, 10 (a) (10) Figure 2 (a) (11) Appendix B (a) (12) Sections 3.3, 3.4.2, 3.4.3, 3.5.5, 3.7.1, 3.7.2, 3.7.3 (b) (2) (B) Sections 3.0, 4.1; Tables 2, 3, 4, 5, 6, 7, 8; Figures 5, 6, 7, 8, 9, 10 (b) (2) (C) Sections 3.0, 4.1.2; Figures 5, 6, 7, 8, 9, 10 (b) (2) (D) Sections 2.1, 3.4.1.3, 3.4.2, 3.5.1.3; Figure 6; Appendices B, I (b) (2) (E) Figure 10 (b) (2) (F) Figure 6 (b) (2) (G) Figure 5 (b) (2) (H) Section 3.5; Tables 3, 4, 5, 7, 8; Figures 5, 8, 9, 10 (b) (2) (I) Section 2.2 (b) (3) (A) Sections 4.1, 4.3, 4.4; Appendix K (b) (3) (B) Sections 4.2, 4.4; Appendix K Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 1 of 26 1.0 PROJECT INFORMATION The existing 480-acre Upper Piedmont Regional Municipal Solid Waste (MSW) Landfill is located in Person County, North Carolina, approximately nine miles east of Roxboro, North Carolina on U.S. Highway 158 (Figure 1). The landfill is owned by and operated by Republic Services of North Carolina, LLC (Republic). Currently, Phases 1, 2, and 3 at the landfill consists of Cells No. 1 through 6. Republic now plans to develop the Phase 4 cell area, which will consist of Cells No. 7 through 10 at the facility. The landfill development is being implemented in phases, as new solid waste cells are needed. This Design Hydrogeologic Report (DHR) addresses the geological, hydrogeological, and geotechnical investigation required for the construction permitting process of future Phase 4. The investigation was performed in accordance with the applicable North Carolina Rules for Solid Waste Management (15A NCAC 13B .1623 (b)). Data from previously performed investigations are compiled into this report, as is relevant to the Phase 4 area. The previous investigations include the following:  Site Hydrogeologic Report, Proposed Person County Regional MSWLF, Highway 158 Tracts, Roxboro, North Carolina, dated May 3, 1995, Law Project Number 2490611302;  Design Hydrogeologic Report, Phase 1 (Cells No. 1A through 4A), Upper Piedmont Regional Landfill, dated January 29, 1996, Law Project Number 30290-5-6113.03;  Addendum to Site Hydrogeologic Report, Dawes Tract, Upper Piedmont Regional MSW Landfill, dated November 8, 2000, BLE Project No. J99-1003-16; and  Design Hydrogeologic Report, Phase 2 (Cells No. 1B through 4B), Upper Piedmont Regional MSW Landfill, dated June 5, 2002 (revised December 3, 2002), BLE Project Number J01-1003-24.  Design Hydrogeologic Report, Phase 3 (Cells No. 5 through 6), Upper Piedmont Regional MSW Landfill, dated May 7, 2007 (revised May 1, 2009), BLE Project Number J06-1003-50. Our geotechnical evaluation of Phase 4 considers both the regulatory liner system employing a 60-mil HDPE geomembrane overlying a two-foot thick compacted clay liner (hydraulic conductivity ≤ 1.0 x 10-7 cm/sec), as well as an alternative base liner consisting of the minimum 60-mil HDPE geomembrane overlying a geosynthetic clay liner (GCL) and an 18-inch thick compacted soil liner (hydraulic conductivity ≤ 1.0 x 10-5 cm/sec). The base liner slopes will be at a 4 horizontal to 1 vertical (4H:1V) inclination or flatter. The interim waste slopes may have a temporary 3H:1V operational slope. The closure cap final grading plan will have slopes of 3.5H:1V or flatter. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 2 of 26 2.0 FIELD INVESTIGATION The Phase 4 area field investigation was conducted from February 2021 to February 2022 in a similar fashion as previous projects at the currently permitted Upper Piedmont Regional MSW Landfill. Including previous phases, the investigation of Phase 4 has included:  conducting soil test borings, rock coring borings, and air-hammer borings;  installing temporary piezometers;  obtaining monthly groundwater elevation measurements;  performing a fracture trace study for the site and surrounding area; and  performing an evaluation of location restrictions as outlined in the applicable solid waste regulations. A discussion of the investigative methodologies used in the site evaluation is provided below. The field activities reported herein were performed under the direction of a North Carolina-licensed geologist and/or engineer. A North Carolina licensed driller from Bridger Drilling of Wilmington, NC performed the borings and piezometer installation during this phase of work. The new boring and piezometer locations were surveyed for horizontal and vertical control, by Wright and Field Surveying, Inc. of Troy, North Carolina, (PLS-2906) after completion of the drilling activities. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 3 of 26 2.1 Test Boring and Soil Sampling The North Carolina Solid Waste Section (SWS) requires that Design Hydrogeologic Studies include the drilling of one boring per acre of permitted cell area. The Phase 4 study area is approximately 46 acres in size. Including previous phases of work and this project, 50 borings have been performed within the Phase 4 study area. The total number of borings performed and piezometers/wells installed across the entire site are summarized below: Phase Exploration Borings Exploration Wells/ Piezometers Remaining Wells/ Piezometers SHR1: Original Site (500 acres) 55 44 17 Phase 1 DHR2: Cells 1A-4A (31 acres) 40 (which included 29 new and 11 existing) 35 (which included 25 new and 10 existing) 0 Phase 2 DHR: Cells 1B-4B (20 acres) 32 (which includes 22 new and 10 existing) 22 (which included 13 new and 9 existing) 0 Phase 3 DHR: Cells 5-6 (20 acres) 34 (which includes 25 new and 9 existing) 24 (which included 15 new and 9 existing) 0 Phase 4 DHR: Cells 7-10 (46 acres) 51 (40 new and 11 pre-existing) 45 (37 new and 8 pre-existing) 42 (37 new and 5 pre-existing) Monitoring Wells 12 12 12 TOTAL 182 146 66 The soil test boring locations and depths were selected to comply with the applicable SWS rules. The locations of the borings are indicated on Figure 2. Soil samples were obtained from the new soil test borings at 2.5-foot intervals within the upper ten feet below the ground surface, and at five-foot intervals deeper than ten feet below the ground surface. Drilling techniques during this current site study consisted of hollow-stem augering and rock core drilling. Refer to Appendix A for discussion of the various drilling techniques used. The soil descriptions were based on visual examination and grain-size estimations in accordance with the Unified Soil Classification System (USCS). Upon completion of laboratory grain-size and Atterberg Limit analyses, the preliminary field classifications were adjusted accordingly on the final boring logs. The final boring log records for the Phase 4 area are included in Appendix B. 2.2 Groundwater Investigation Thirty-seven (37) new piezometers were installed to monitor water table elevations and further characterize the study area hydrogeology. The new piezometers supplement the eight (8) piezometers installed during prior work in the Phase 4 area. Piezometer installation records are included with the boring logs in 1 Site Hydrogeology Report - One boring per 10-acres is required. 2 Design Hydrogeology Report - One boring per acre of cell footprint is required. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 4 of 26 Appendix B, and field installation procedures described in Appendix C. Survey information for the new piezometers is included in Appendix D. Survey data and well/piezometer construction details are summarized on Table 1 and Table 2. Groundwater elevations were measured in the new piezometers at the time of boring, after 24 hours, and monthly measurements were collected from the piezometers and monitoring wells on site during the period from February 2021 to February 2022 to determine the seasonal high groundwater levels; these water level measurements are summarized on Table 3. Historical water level data from other piezometers and monitoring wells during the period from September 2006 through February 2022 are provided on Table 3. Precipitation data for the North Carolina Northern Piedmont division (Climate Division 3) is included in Appendix E. Field permeability (slug) tests were performed in eleven (11) piezometers in the study area to measure the in situ hydraulic conductivity of different units of the water table aquifer. Slug test field procedures and data plots are presented in Appendix F and the results are summarized on Table 4. The piezometers are intended only for investigative use, were not constructed as permanent monitoring wells, and were not part of the permanent groundwater monitoring system. Prior to construction activities, all piezometers within the Phase 4 area will be abandoned in accordance with 15A NCAC 2C, Rule .0113(d)(2) by over-drilling to the full depth of the boring or to the top of bedrock (whichever is encountered first) and filling the resulting boreholes with bentonite grout and/or bentonite chips. The level of the grout within the over-drilled boring will not exceed the elevation of the proposed base grade. 2.3 Laboratory Testing Laboratory testing of soil samples were conducted to confirm the field classifications and quantify pertinent engineering soil properties. Soil samples were collected using split-spoon samplers and Shelby tubes (relatively undisturbed samples). The laboratory tests were performed in general accordance with applicable ASTM specifications, where available. Brief descriptions of the test procedures are included in Appendix G. Soil laboratory testing results are included in Appendix H and are summarized on Tables 5 and 6. 2.4 Fracture Trace Analysis The fracture trace analysis consisted of evaluating exposed rock outcrops and topographic fracture traces and lineaments as discussed below. No new exposed outcrops or topographic features were discovered during this DHR. The data plots of historical data from Phases 1-3 are included in Appendix I and the methods of data collection are below. Exposed Rock Outcrops: Using a Brunton compass, the orientations of exposed bedrock fractures (open joints, open foliation, open bedding planes) were measured. The field measurements were plotted on a Schmidt lower hemisphere equal-area stereonet and Rose diagrams. Topographic Fracture Traces and Lineaments: Regionally, pronounced depressions typically develop along zones of weakness in the bedrock where fractures induce preferential weathering. This preferential weathering along the bedrock fractures is ultimately expressed topographically as linear valleys. The trend of fracture traces and lineaments greater than 1,000 feet in length within a 2-mile radius of the site were measured from topographic maps and plotted as data on Rose diagrams. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 5 of 26 2.5 Surface Geophysical Survey A geophysical survey was conducted at the site using a portable proton magnetometer to determine if diabase dikes are present within the upper 20 to 50 feet of the subsurface. The geophysical survey was conducted along 30 lines for a total of about 37,000 feet (approximately 7 miles) across the entire site. The lines were located along existing clearings and through forested areas. The magnetometer can detect magnetic materials such as diabase dikes, or other similar rock types, containing ferromagnetic and associated minerals. The magnetometer survey was conducted using an EGG Geometrics model G-856A portable magnetometer. Data were measured at 15 to 30-foot intervals along the survey lines. The instrument stored the measured total magnetic field intensity, magnetic gradient, and time for each geophysical survey station along each line. A general description of the geophysical methodology and results of the survey are included in Appendix J. 2.6 Field Reconnaissance The study area was traversed to map rock outcrops and surface drainage features. The information obtained was integrated with the geologic information already collected at the site during previous phases of work. As discussed in Section 2.4, no new exposed outcrops or topographic features were discovered during this DHR. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 6 of 26 3.0 RESULTS OF INVESTIGATION 3.1 Regional Geology The subject site is located within the Carolina Slate Belt of the Piedmont Physiographic Providence (Figure 3 and Figure 4). The crystalline rocks of the Piedmont Province occur in generally northeast-southwest trending geologic belts in the Carolinas and Virginia. The basement bedrock of the Carolina Slate Belt, in the vicinity of Roxboro, North Carolina, consists of extrusive and intrusive volcanic rock types with varying degrees of deformation and metamorphism. The area surrounding the site primarily consists of extrusive volcanic rocks about 575 to 620 million years old, which were slightly deformed and metamorphosed about 300 to 520 million years ago (Glover and Sinha, 1973). The dominant structures near the site are open folds striking northeast and plunging southwest, and the regional metamorphism is chlorite or greenschist grade (Glover and Sinha, 1973; Robinson and others, 1985). These structures are located on the southeast flank of the Virgilina Synclinorium. There are three primary extrusive volcanic rock formations in the northern Carolina Slate Belt: Virgilina Formation, Aaron Formation, and Hyco Formation (oldest of the three formations). According to Glover and Sinha (1973) and Harris and Glover (1985), the volcanic rocks in the area of the site are part of the Hyco Formation, which is primarily composed of rhyodacitic and andesitic pyroclastic rocks, with minor amounts of shallow intrusives, and lavas. Pyroclastic rock textures range from fine tuff to tuff breccia. The intermediate pyroclastic rocks are similar in texture to their felsic counterparts. Mafic rocks are not common, but are present along the eastern flank of the Virgilina Synclinorium. Mesozoic age diabase dikes are common in the Carolina Slate Belt. Generally, in the southeastern Appalachians, a relatively older northwest-trending set of diabase dikes and a relatively younger north- trending set of diabase dikes are present (De Boer and Snider, 1979). Diabase dikes in Person County are sparse. There are no diabase dikes mapped on the site. The closest known diabase dikes to the site are mapped in the southwest corner of Person County (about 16 miles west of the subject site) and western Granville County (about 4 miles east of the subject site). Holocene and younger age faults were not indicated on site or within 200 feet of the site from the literature review and from the field reconnaissance. The typical residual soil profile consists of clayey soils near the surface, where soil weathering is more advanced, underlain by sandy silts and silty sands. Residual soil zones develop by the in situ chemical weathering of bedrock, and are commonly referred to as “saprolite.” Saprolite usually consists of silt with lesser amounts of sand, clay and large rock fragments. The thickness of the saprolite in the Piedmont ranges from a few feet to more than 100 feet. The boundary between soil and rock is not sharply defined. A transitional zone of partially weathered rock is normally found overlying the parent bedrock. Partially weathered rock is defined, for engineering purposes, as residual material with standard penetration resistance in excess of 100 blows per foot (bpf). Fractures, joints, and the presence of less resistant rock types facilitate weathering. Consequently, the profile of the partially weathered rock and hard rock is quite irregular and erratic, even over short horizontal distances. Also, it is not unusual to find lenses and boulders of hard rock and zones of partially weathered rock within the soil mantle, well above the general bedrock level. Often during construction, this material can be excavated using conventional earth moving equipment. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 7 of 26 3.2 Regional Hydrogeology Groundwater in the Piedmont usually occurs as unconfined, water table aquifers in three primary geologic zones: 1) residual soil; 2) partially weathered rock; and 3) fractured bedrock. These zones are typically interconnected through open fractures and pore spaces. The configuration of the water table aquifer generally resembles the local topography. In the residual soil and partially weathered rock zones, groundwater is stored within the pore spaces and is released to the underlying bedrock through gravity drainage. Groundwater within the bedrock zones occurs primarily in fracture voids. Generally, fractures within the bedrock are very small but may extend to several hundred feet. Infiltration of precipitation to recharge the water table aquifer is primarily affected by rainfall intensity and duration, pre-existing soil moisture conditions, temperature (evaporation), and plant uptake (transpiration). Seasonal high-water tables are typically observed during the late winter and spring months of the year when maximum infiltration efficiency occurs due to lower temperatures and less plant uptake (i.e., many plants are dormant). Seasonal-low water tables are typically observed during the summer and fall months when minimum infiltration efficiency occurs due to higher temperatures and greater plant uptake of water. 3.3 Study Area Physiography and Topography The landfill is located in Person County, North Carolina, as shown in Figure 1. The Phase 4 area is bounded on the west by the landfill’s existing borrow area, on the north by existing landfill cells 1A and 1B, on the east by a former borrow area, and on the south by the existing property buffer. The western half of the Phase 4 area is currently comprised of hardwood forest and the eastern half consists of softwood (pine) forest. The U.S. Department of Agriculture (USDA) soil survey of Person County indicates that soil types in the upland elevations in the study area include the Herndon loam with 2 to 6 percent slopes, Iredell gravelly loam with 2 to 6 percent slopes, and the Lignum loam with 2 to 6 percent slopes (USDA, 2022). Topographically, the ground-surface elevation drops off from north to south across Phase 4. The steepest slopes in the study area are located in the northwestern portion of Phase 4. The highest elevations (approximately 680 ft NAVD88) occur in the northwestern portion of Phase 4 with the lower elevations (approximately 584 ft NAVD88) occurring at the southwestern portion of Phase 4. The relief across the Phase 4 area is approximately 96 feet. The existing surface drainage pattern in the Phase 4 area is generally to the south towards an unnamed ephemeral stream. During high precipitation months (Winter and Spring), surface runoff that does not flow to an ephemeral stream ponds at a topographic low near the southeastern corner of the Phase 4 area. A topographic map/site plan is provided as Figure 2. 3.4 Study Area Subsurface Conditions Fifty-one (51) borings have been performed in and adjacent to the Phase 4 area at the locations shown on Figure 2. The geologic conditions encountered while drilling were often variable with boulders and seams of partially weathered rock occurring throughout the subsurface soil overburden profile. In general, three zones were encountered: 1) the residual soils, 2) the partially weathered rock, 3) the bedrock. Subsurface geology at the site is shown on two (2) cross sections designated A-A' and B-B' (Figure 5). The subsurface Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 8 of 26 conditions encountered in the Phase 4 area are consistent with previous evaluations at the site (Section 1.0). A description of the subsurface materials encountered is provided below. 3.4.1 Geologic Unit Description 3.4.1.1 Residual Soil Residual soils are the result of in-place weathering of rhyolite and andesite bedrock. The residual soil profile below the topsoil consists of two identifiable components based on the USCS. An upper soil component consists of reddish-brown and gray silty clay and sandy clayey silt. This component was encountered in 22 of the 40 new soil test borings in the Phase 4 area. Where encountered, the thickness of this component ranges from 3 to 27 feet below ground surface, with an average thickness of 6.7 feet. USCS classifications of these soils are CL, CH, ML, and MH. Standard penetration resistance values (N-values) range from 4 to 39 with an average value of 11.5, indicating a stiff average consistency. The upper soil component grades with depth into a coarser grained, less plastic, gray and brown sandy silt and silty sand which extends to the depth of the partially weathered rock and/or auger refusal. This deeper soil component was encountered in 26 of the 40 new soil test borings, and ranges in thickness from 2.5 to 22.5 feet across the Phase 4 area, with an average thickness of 7.5 feet. USCS classifications of these soils are ML and SM. N-values range from 4 to 79 with an average of 29, indicating a very firm average consistency. Float rocks (small boulders) were present in some locations at the ground surface and within the residual soil zone above the partially weathered rock level. 3.4.1.2 Partially Weathered Rock (PWR) The transition between soil and rock at the site is irregular and consists of partially weathered rock (PWR) overlying the parent bedrock. The PWR horizon is typically characterized by N-values exceeding 100+. The PWR consists primarily of gray and brown, silty, fine to coarse sand with varying amounts of gravel size rock fragments. USCS classifications of these soils are typically SM. Where encountered, this zone was found to range in thickness from 3 to 22 feet, with an average thickness of 10.6 feet. This zone also includes various float rock and boulders indicative of the varying weathering patterns. 3.4.1.3 Fractured Bedrock The upper bedrock profile at these locations is fractured, severely to slightly weathered, and slightly metamorphosed rhyolite and andesite, rhyolite and andesite porphyry (tuff), and rhyolitic tuff breccia. The bedrock encountered is part of the Hyco Formation. Alternating rock seams and partially weathered rock zones are common. Where present, relict bedding consists of thin, shallow dipping layers. Tuffs and tuff breccia are massive (i.e., bedding is not apparent). Bedrock coring has been performed at six (6) different locations for a total of 102.8 feet. The bedrock core had generally “fair” recovery (range of 7 to 99 percent; average of 75 percent) and “poor” RQD (range of 0 to 90 percent; average of 28 percent). In general, the bedrock becomes more competent with depth. The upper bedrock is typically highly fractured. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 9 of 26 A map of the approximate bedrock surface (auger refusal) is shown as Figure 6. Auger refusal depths may represent competent bedrock or possibly boulders of hard rock within the residual soil and partially weathered rock units. The depth to auger refusal can vary even over short horizontal distances due to boulders, fractures, joints, and the presence of less resistant rock types. Therefore, the actual depth to continuous bedrock may vary from that presented on Figure 6. A geologic map of the predominant bedrock types at the site is provided as Figure 7. The geologic map is based on information collected from bedrock outcrops, corings, boulders, soil borings, and surface geophysics. 3.4.2 Fracture Trace Analysis A fracture trace analysis was performed and reported along with the data plots (Rose diagrams, Schmidt equal area plots) as part of previous SHR and DHR studies (Section 1.0), plus geologic observations during subgrade preparation of the cells in Phases 1, 2, and 3. The new data from the study area has been incorporated into the fracture trace analysis. A summary of the fracture trace analysis is provided below. The Rose diagrams, Schmidt net plots, field data, and topographic lineament maps for the fracture trace analysis are included in Appendix I. The orientations and trends of 144 open joint, foliation, quartz vein, and bedding surfaces were measured at the site. The data was collected at the site from rock outcrops and excavated areas prior to cell construction. The collected data has been plotted on Schmidt equal area projections and Rose diagrams as follows: one Schmidt net for plotting poles to the fractures, and one Rose diagram utilizing a 10° interval for fracture trends. Three primary fracture orientations were observed: N11°-40°E, dipping 75°-90°NW to 60°-90°SE; N81°-90°W, dipping 70°-90°N; and N31°-40°W, dipping 70°-90°SW to 70°-90°NE. Results of the fracture trace analysis indicate that local and regional prevailing fracture trends are north- northeast and north-west. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 10 of 26 3.4.3 Surface Geophysical Survey A surface geophysical survey (e.g., proton magnetometer) was performed and reported as part of previous SHR and DHR (Phase 1) studies (Section 1.0) at the landfill. Approximately 7 miles (37,000 feet) of geophysical survey lines were performed over the entire landfill site. A summary of the results of the survey are provided in Appendix J and described below. Magnetic anomalies observed during the geophysical survey were sporadic and a function of the varying ferromagnetic mineral content of the bedrock on site. The magnetometer recorded background total magnetic field intensities of approximately 52,700 nanoteslas (nT). In general, the lower magnetic readings were in the areas of rhyolitic bedrock, intermediate magnetic readings were in the areas of andesitic bedrock, and the highest magnetic readings were in the areas of basaltic bedrock. Magnetic anomalies were not consistent with trends indicative of diabase dikes. Based on these results, no diabase dikes were identified within the site limits. Furthermore, the site reconnaissance performed as part of this DHR did not result in the visual identification of diabase dikes. 3.4.4 Laboratory Testing Results Fourteen (14) split-spoon samples, eight (8) Shelby tube samples, and three (3) remolded samples were collected and tested in the laboratory to measure natural soil conditions in the Phase 4 area. The laboratory test results are summarized in Table 5 and Table 6. Soil laboratory data sheets are in Appendix H. Testing results of the eleven (11) samples collected from the upper residual soil component consisted of:  Natural moisture content values ranging from 11.0 to 36.2 percent;  Liquid Limit (LL) values ranging from 27 to 72;  Plasticity Index (PI) values ranging from 5 to 54;  Average gravel, sand, silt, and clay contents of 1.4, 19.6, 42.7, and 37.1 percent, respectively;  In-situ hydraulic conductivity values ranging from 9.1 x 10-8 to 1.4 x 10-5 cm/sec;  Total porosity values ranging from 45.3 to 56.3 percent;  Effective porosity values ranging from 1.0 to 22.5 percent; and  A Standard Proctor result with an optimum moisture content of 18.0 percent and a maximum dry density (MDD) of 101.9 pcf. Testing results of the seven (7) samples collected from the deeper residual soil component consisted of:  Natural moisture content values ranging from 9.3 to 47.9 percent;  LL values ranging from 29 to 54;  PI values ranging from 4 to 22;  Average gravel, sand, silt, and clay contents of 6.6, 30.1, 46.5, and 24.0 percent, respectively;  In-situ hydraulic conductivity values ranging from 5.1 x 10-6 to 2.1 x 10-5 cm/sec;  Total porosity values ranging from 39.8 to 56.0 percent;  Effective porosity values ranging from 11.0 to 24.3 percent;  Consolidation testing of an in-situ sample indicated a preconsolidation pressure (Pp) of 7.18 ksf, a virgin compression ratio (cc) of 0.41, and a void ratio (eo) of 1.147;  Triaxial testing of an in-situ sample indicated total stress and effective cohesion (C) of 0.77 and 0.33 ksf, respectively, and a total stress and effective friction angle of 12.2 and 27.31 degrees, respectively; Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 11 of 26  Triaxial testing of a remolded sample indicated total stress and effective cohesion of 0.257 and 0.091 ksf, respectively, and a total stress and effective friction angle of 17.24 and 30.3 degrees, respectively; and  Standard Proctor results with optimum moisture contents of 11.9 and 19.5 percent and MDD’s of 103.4 and 121.4 pcf. Testing results of the 5 samples collected from the partially weathered rock component consisted of:  Natural moisture content values ranging from 8.4 to 11.9 percent;  LL values ranging from 24 to 33;  PI values ranging from 7 to 13;  Average gravel, sand, silt, and clay contents of 16.0, 50.7, 22.6, and 10.7 percent, respectively;  Total porosity values ranging from 34.1 to 49.0 percent; and  Effective porosity values ranging from 18.4 to 27.6 percent. 3.5 Study Area Hydrogeology Fifty-one (51) borings were performed in the Phase 4 area as shown on Figure 2. Of those fifty-one (51) borings, forty-five (45) borings were used for piezometer installation. Groundwater in the Phase 4 area is present above the bedrock surface in the lower elevation areas, but groundwater occurs at or near the bedrock surface in higher elevation areas. The water-table aquifer in the Phase 4 area consists of the residual saprolitic soil, partially weathered rock, and fractured bedrock. These units are hydraulically connected and thus comprise a single unconfined aquifer, although recharge rates, flow rates and storativity differ between the units based on the unique geologic conditions of each zone. The hydrogeologic conditions encountered in the Phase 4 area are consistent with the conditions encountered during previous phases of hydrogeologic work at the landfill. A description of the hydrogeologic conditions in the study area is provided below. 3.5.1 Piezometer Construction and Nomenclature Piezometer identification numbers were designated with the letters “a,” “b,” or “c” depending on the location of the screened interval in the piezometer. Piezometers with a screened interval that brackets the water table and is above the depth of auger refusal were designated with the letter “a”. Piezometers with a screened interval at the depth of auger refusal (top of bedrock surface) and below the water table were designated with the letter “b”. In cases where the water table was near the depth of auger refusal, the piezometer identification number was designated using “ab”. Bedrock piezometers were designated with the letter “c”. Piezometers that are dry do not have a letter designation. The groundwater monitoring wells do not use this nomenclature. A typical schematic diagram of piezometer construction and nomenclature is provided in Appendix B. 3.5.1.1 Residual Soil Piezometers Six (6) piezometers were installed with screened intervals in the saprolitic residual soils. One (1) of these piezometers was preexisting and five (5) piezometers were recently installed. These piezometers include the following: PZ-11a PZ-148B PZ-140B PZ-152B PZ-146AB PZ-153B Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 12 of 26 3.5.1.2 Partially Weathered Rock Piezometers Thirty-three (33) piezometers were installed with screened intervals in the partially weathered rock. Two (2) of the piezometers were previously abandoned, two (2) piezometers were previously installed and are existing, and twenty-nine (29) were recently installed. These piezometers include the following: PZ-19ab (Abandoned) PZ-72ab PZ-129B PZ-133B PZ-136B PZ-141B PZ-143B PZ-147B PZ-151B PZ-156B PZ-159B PZ-20ab PZ-126B PZ-131AB PZ-134AB PZ-137B PZ-142B PZ-144B PZ-149B PZ-154B PZ-157B PZ-160B PZ-62ab (Abandoned) PZ-128B PZ-132B PZ-135B PZ-138B PZ-143B PZ-145B PZ-150B PZ-155B PZ-158B PZ-161B 3.5.1.3 Bedrock Piezometers and Groundwater Monitoring Wells Five (5) piezometers and one (1) groundwater monitoring well were installed with screened intervals in the bedrock zone. One (1) piezometer was previously abandoned, one (1) piezometer was preexisting, and three (3) piezometers were recently installed. These piezometers include the following: PZ-19c (Abandoned) PZ-139C PZ-22c PZ-162C PZ-133C GW-6 3.5.2 Seasonal High Groundwater Elevations The relationship between precipitation and groundwater level trends at the site was evaluated from 2006 to 2022. The following sources of data were used to evaluate the seasonal high water level at the site:  Historical National Oceanic and Atmospheric Administration (NOAA) precipitation data were obtained to establish seasonal trends for the Person County area (http://www.ncdc.noaa.gov/oa/climate/climatedata.html);  Historical water level measurements from pre-existing piezometers and monitoring wells (parts of prior hydrogeologic studies at the facility) between September 2006 and February 2021; and  Monthly water level measurements from the piezometers and monitoring wells at the facility between March 2021 and February 2022. Historical NOAA monthly precipitation data were obtained from Division 3, North Carolina for the period of January 1991 through February 2022. The data are summarized seasonally in Appendix E such that January-March represents winter, April-June represents spring, July-September represents summer, and October-December represents fall. Historically in the Person County area, summer months will experience the most precipitation. However, the effects of evapotranspiration offset the contribution of this precipitation to recharge of the uppermost aquifer. Significant precipitation also occurs in the spring and winter months when evapotranspiration is Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 13 of 26 limited (i.e., cooler weather and less plant uptake). Because of these natural trends, the amount of groundwater recharge, and subsequent increase in water table level is typically greatest during winter and spring seasons. The winter months of 2021 (January through March) experienced above average amounts of precipitation in the North Carolina Division 3 region (see precipitation data in Appendix E); therefore, the monthly water levels collected from the piezometers and wells during February 2021 to March 2021 represent above normal seasonal high groundwater levels (Table 3). The spring 2021 through winter 2022 months (April 2021 through February 2022) experienced below average amounts of precipitation in the North Carolina Division 3 region (Appendix E); therefore, the monthly water levels collected from the piezometers and wells during April 2021 to February 2022 represent slightly below normal seasonal high groundwater levels (Table 3). Figure 9 is the composite seasonal high water table for the water levels collected between February 2021 and February 2022. Many of the water level measurements recorded between February and March 2021 are represented on Figure 9 due to the above average amount of precipitation (Appendix E) in 2020 and winter 2021. The groundwater elevations at the wells and piezometers, and the groundwater elevation contours on Figure 9 should be used for landfill subgrade design, along with the bedrock (auger refusal) elevations shown on Figure 6. 3.5.3 Estimated Long-Term Seasonal High Groundwater Elevations Figure 10 is an estimation of the long-term seasonal high water table, which is based on both data collected and our interpretation of the data. Each well and piezometer did not experience the highest measured water level to date during the same year. As a consequence, a single season (year) could not be selected for preparation of a long-term seasonal high water table map. As a conservative approach, the groundwater contours on Figure 10 were established using site-specific maximum groundwater elevation measurements between September 2006 and February 2022. In areas where piezometers were not present, the contours are estimated based on the typical gradients and the configuration of historical groundwater elevation contour maps prepared for the site in previous DHRs and the October 27, 2021 water table map (Figure 8). Typical seasonal high groundwater levels to be used in future design hydrogeological investigations are anticipated to be at lower elevations. 3.5.4 Groundwater Flow Direction Groundwater beneath the Phase 4 study area flows to the south and east. The water table configuration is similar to the site topography. Recharge to the unconfined aquifer occurs at the higher elevations. Shallow groundwater discharge occur to the stream south of Phase 4 within the property boundary. 3.5.5 Man-made Influences to Groundwater Levels Man-made features on the landfill property that could influence groundwater levels in the Phase 4 area include existing and proposed lined waste cells, ditches next to roads, and existing and proposed sediment basins. Currently, Cells No. 1A through 6A and 1B through 5B have been constructed topographically upgradient of the Phase 4 area. As cell construction proceeds, groundwater infiltration and recharge of the water table aquifer will be limited, resulting in lower groundwater levels in the vicinity of the lined cells. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 14 of 26 Sediment Basin No. 1 east of the Phase 4 area could artificially mound the water table in its vicinity. The on-site ephemeral stream is the downgradient discharge area for shallow groundwater. 3.5.6 Hydraulic Coefficients and Groundwater Flow Velocity The velocity of groundwater flow is derived from the equation: = Where V is the flow velocity; K is the hydraulic conductivity; i is the hydraulic gradient; and ne is the effective porosity. Estimated values for each of these parameters were developed based on site-specific subsurface data and are provided below. The parameters are summarized on the attached Tables 4, 5, and 7. 3.5.6.1 Hydraulic Conductivity Hydraulic conductivity is defined as the ability of the aquifer material to conduct water under a hydraulic gradient. Eight slug tests have been performed in the Phase 4 area to measure the in situ hydraulic conductivity of the different zones of the water-table aquifer. The slug test results were evaluated using the Bouwer and Rice Method (1976) for partially-penetrating wells in an unconfined aquifer (Table 4 and Appendix F). The slug tests performed include:  Two (2) tests in wells/piezometers set in the deep residuum soil unit (PZ-148B and PZ-153B);  Four (4) tests in piezometers set in the partially weathered rock unit (PZ-20ab, PZ-132B, PZ-142B, and PZ-158B); and  Three (3) tests in piezometers set in the bedrock unit (GW-6, PZ-22c, and PZ-139c). Based on the slug tests conducted in the Phase 4 area, the range of hydraulic conductivity values is as follows:  6.7 x 10-6 cm/sec (PZ-153B) to 3.9 x 10-5 cm/sec (PZ-148B) in the deep residuum soil unit;  1.3 x 10-6 cm/sec (PZ-158B) to 3.3 x 10-5 cm/sec (PZ-132B) in partially weathered rock unit; and  2.8 x 10-7 cm/sec (PZ-139C) to 2.2 x 10-6 cm/sec (PZ-22c) in the bedrock unit. 3.5.6.2 Hydraulic Gradient The hydraulic gradient is determined by dividing the difference in groundwater elevations at two locations by the horizontal distance between those locations along the direction of groundwater flow. In order to use synchronous measurements for representative gradients, hydraulic gradients were measured from the October 27, 2021 groundwater elevation contour map (Figure 8). Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 15 of 26 In the Phase 4 area, hydraulic gradients range from approximately 0.028 ft/ft near the south western portion of Phase 4, to approximately 0.088 ft/ft near the north western portion of Phase 4 (Table 7). 3.5.6.3 Effective Porosity and Specific Yield Effective porosity is the volume of void spaces through which water or other fluids can travel in soil divided by the total volume of the soil. Effective porosity can be assumed to be approximately equal to specific yield. Specific yield is defined as the ratio of the volume of water which gravity drains from saturated sediment to the total volume of soil. The laboratory grain size analyses were used to derive values for specific yield and effective porosity (Table 5 and Appendix H). Based on soil laboratory data and published geologic literature, effective porosity measurements in the Phase 4 area range from about:  1.0% to 22.5% (average = 18.6%) in the shallow residuum soil unit  11.0% to 24.3% (average = 19.6%) in the deep residuum soil unit;  18.4% to 27.6% (average = 22.0%) in the partially weathered rock unit; and  the effective porosity can be expected to range from about 5% to 10% for fractured crystalline bedrock unit (average = 7.5%) according to Kruseman and deRidder, 1989. 3.5.6.4 Groundwater Flow Velocity The velocity of groundwater movement (V) is a function of existing hydraulic gradient (i), the hydraulic conductivity (K), and the effective porosity (ne), in the equation V = Ki/ne. Based on these parameters and the data provided above, the geometric mean horizontal movement of groundwater across the Phase 4 area is approximately:  0.002 to 0.088 (average 0.011) feet/day in the deeper residual soil unit;  0.0004 to 0.043 (average 0.005) feet/day in the partially weathered rock unit; and  0.00028 to 0.0176 (average 0.001) feet/day in the bedrock unit. The maximum and minimum values for each unit represent a range of values using available data. The average values are more representative of site-wide conditions. Table 7 summarizes the average groundwater flow velocity calculations. 3.6 Summary of Geologic and Hydrogeologic Formation Properties Geologic and hydrogeologic characteristics of the soils and bedrock in the Phase 4 area are summarized on Table 8 for each of the geologic units. The values observed are in the general range of values observed from across the entire site as documented in prior SHR and DHR studies. 3.7 Geotechnical Considerations An evaluation of the potential impact from faults, seismic zones and unstable areas, as required by 15A NCAC13B.1622, was previously prepared for the current landfill site and documented as part of the Site Hydrogeologic Report dated May 3, 1995 (LAW Engineering Job Number 2490611302). These items are briefly summarized below to provide a background for our geotechnical evaluation. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 16 of 26 3.7.1 Fault Areas No Holocene faults are located within 200 feet of the subject site (Horton and Zullo, 1991). 3.7.2 Seismic Impact Zones According to the definition of seismic impact zones in 15A NCAC 13B.1622 (5), this site is not in a seismic impact zone. The maximum horizontal acceleration, expressed as a percentage of the earth's gravity (g), in rock is approximately 0.07g with a 2% probability of being exceeded in 50 years (approximately equal to 10% probability in 250 years; Petersen MD et al, 2018). 3.7.3 Unstable Areas An unstable area according to 15A NCAC 13B.1622 (6) is defined as a location that is susceptible to natural or human induced events or forces capable of impairing the integrity of some or all of the landfill structural components responsible for preventing releases from a landfill. Unstable areas could include poor foundation conditions, areas susceptible to mass movements, and karst terrains. Site and subsurface data obtained were evaluated to determine if unstable site areas exist. The site is not in a region susceptible to karstification. Soils susceptible to dynamic liquefaction were not encountered and are not typical for the region. No unstable foundation conditions were present. BLE will provide an evaluation of settlement and slope stability conditions for the Phase 4 area under separate cover in the report titled Geotechnical Evaluation – Planned Phase 4, Upper Piedmont Regional MSW Landfill, (BLE Project No. J21-1003-81B). Sediment resulting from storm water flow is deposited at the bottoms of slopes at the landfill site. Soft sediments (where present) are to be removed from the cell footprint and areas supporting the structural fill slopes of the landfill perimeter prior to structural fill placement. 3.7.4 Permeability of Potential On-Site Soils for Liner and Cover Construction Prior DHR and borrow studies performed at the facility have identified on-site low permeability soils for landfill construction use. Based on the subsurface data encountered during this DHR exploration, low permeability surficial soils that could be used to construct a regulatory clay liner (k ≤ 1.0 x 10-7 cm/sec), or an alternative base soil liner or final cover cap (k ≤ 1.0 x 10-5 cm/sec) are present on site in limited quantities. Careful selection and use, or temporary stockpiling, of these clayey soils will be required during landfill cell development and closure construction. The in situ moistures of the silty clay will vary based on recent rainfall; however, they should be found at moisture contents within a few points of the standard Proctor optimum moisture content. Some modification of moisture will be required during soil liner or cap construction. 3.7.5 Earthwork Activities Excavations of the existing residual soils are anticipated to be made to achieve the planned design grades. An estimated top of rock (auger refusal) contour map was developed and is presented in Figure 6 of this report. The estimated top of rock is based on auger refusal depths in the soil borings drilled at this site. Materials sufficiently hard to cause refusal to the mechanical drill augers may result from continuous bedrock, boulders, lenses, ledges, or layers of relatively hard rock within the overburden residual soil. Coring was performed at three (3) locations where auger refusal occurred. Continuous rock was found with varying recovery and Rock Quality Designation (RQD) as discussed above in Section 3.4.1.3. Due to its Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 17 of 26 typically varying surface, the actual occurrence of hard rock during site grading may vary from that presented in Figure 6. Very dense soil and partially weathered rock such as that encountered in the borings may present difficulty in excavating during construction. There is usually no sharp transition between soil and rock in areas of undisturbed residual materials. Typically, the degree of weathering simply decreases with greater depth until solid rock is eventually reached. The partially weathered rock, as well as the soil above, may also contain boulders, lenses or ledges of hard rock. The mechanical auger used in this exploration could penetrate some of the partially weathered rock of the transitional zone. The ease of excavation depends on the geologic structure of the material itself, such as the direction of bedding, planes or weakness and spacing between discontinuities. Our experience indicates that PWR that has a standard penetration resistance of 50 blows over 3-inches or less (i.e. 50 blows resulted in 3-inches or less of penetration), as indicated on the boring records, will be difficult to remove by ripping and may require blasting. The residual soils without organic material that will be excavated from the cell areas to achieve the design subgrade elevations are suitable for use as structural fill. Some moisture modification (wetting or drying) will be required depending on the particular area of excavation. Conventional compaction equipment and methods should be appropriate for excavation of residual soils. Design considerations and recommendations to form stable slopes and to provide acceptable base liner interface friction will be outlined in BLE’s geotechnical report for Phase 4 (BLE Project No. J21-1003-81B). Fill soil used for raising site grades or for replacement of material that is over-excavated as a result of poor proofrolling performance should be uniformly compacted to at least 95 percent of the standard Proctor maximum dry density (ASTM D 698). Partially weathered rock may be mixed with the soil borrow materials provided it can be broken down by the excavation and compaction equipment into particles with a maximum dimension of 6 inches. Larger boulders or rock pieces may be used in the lower portions of the deeper fills if the boulders are placed individually and soil compacted around and over each boulder. Sufficient quantities of soil should be mixed with the partially weathered rock so that voids do not result between the pieces of partially weathered rock and the fill meets the compaction requirements. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 18 of 26 4.0 WATER QUALITY MONITORING PLAN A detailed Water Quality Monitoring Plan (WQMP) has been prepared to comply with Rule .1623(b)(3) which is provided as a separate document. The WQMP provides a means to monitor groundwater (monitoring wells) and surface water quality in background/upgradient locations and at the relevant point of compliance, downgradient from the waste to be placed in Phase 4, as well as existing Cells No. 1 through 6. Provided below is a summary of the additions to the WQMP as a result of the proposed development of Phase 4. A comprehensive discussion of the existing and proposed components of the WQMP (well construction diagrams, sampling procedures, analytical testing procedures, well installation procedures, and reporting procedures) is included in the WQMP. 4.1 Groundwater Monitoring Plan 4.1.1 Subsurface Considerations Site specific factors were considered in designing this groundwater detection monitoring system, including the locations and construction details of each proposed monitoring well. In addition, environmental factors were considered, such as seasonal variations of the water table, the horizontal and vertical flow regimes, and lithology characteristics. The residual soils, partially weathered rock, and shallow bedrock comprise the unsaturated and saturated zones of the uppermost water table aquifer. 4.1.2 Relevant Point of Compliance The relevant point of compliance has been established less than 250 feet from the boundary of future Phase 4. Where site access allows, the proposed wells will be placed approximately 250 feet from the waste boundary. In all cases, this relevant point of compliance is more than 50 feet from the facility property boundary. The determination of the relevant point of compliance was based on the following factors:  The hydrogeologic characteristics of the facility and the surrounding land;  The anticipated physical/chemical characteristics of the leachate;  The direction of groundwater flow;  The proximity and direction of groundwater users;  The availability of alternative drinking water supplies;  Public health, safety, and welfare effects; and  Practicable capability of the owner or operator. 4.1.3 Monitoring Well Locations Existing background monitoring well GW-1R will serve as the background well in the Phase 4 area. Well GW-1R is screened in the fractured bedrock. No additional background monitoring wells are required. Sixteen additional downgradient wells (GW-13 through GW-28) will be required to monitor groundwater downgradient from Phase 4. The approximate locations of the proposed monitoring wells are shown on Figure 2 of the WQMP. The proposed new downgradient locations were selected based on the potentiometric surface elevation contour map and flow lines of the groundwater elevation contour maps (Figures 8, 9, and 10 in the DHR). The proposed new monitoring well locations are discussed in the WQMP and in the following table: Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 19 of 26 Monitoring Location Proposed Monitoring Well Location and Justification GW-13 (proposed) Proposed sidegradient well that will intersect water table west of Cell No. 7B. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 7B. The well will be installed in conjunction with Cell No. 7B construction. GW-14 (proposed) Proposed sidegradient well that will intersect water table west of Cell No. 7B. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 7B. The well will be installed in conjunction with Cell No. 7B construction. GW-15 (proposed) Proposed downgradient well that will intersect the water table south of Cell No. 7B. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 7B. The well will be installed in conjunction with Cell No. 7B construction. The well will be abandoned in conjunction with Cell No. 8B construction. GW-16 (proposed) Proposed downgradient well that will intersect the water table south of Cell No. 7A. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 7A. The well will be installed in conjunction with Cell No. 7A construction. The well will be abandoned in conjunction with Cell No. 8A construction. GW-17 (proposed) Proposed downgradient well that will intersect the water table south of Cell No. 7A. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 7A. The well will be installed in conjunction with Cell No. 7A construction. The well will be abandoned in conjunction with Cell No. 8A construction. GW-18 (proposed) Proposed downgradient well that will intersect the water table south of Cell Nos. 7A and 8A. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell Nos. 7A and 8A. The well will be installed in conjunction with Cell No. 7A construction. GW-19 (proposed) Proposed sidegradient well that will intersect water table west of Cell No. 8B. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 8B. The well will be installed in conjunction with Cell No. 8B construction. GW-20 (proposed) Proposed downgradient well that will intersect the water table south of Cell No. 8B. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 8B. The well will be installed in conjunction with Cell No. 8B construction. The well will be abandoned in conjunction with Cell No. 9 construction. GW-21 (proposed) Proposed downgradient well that will intersect the water table south of Cell No. 8A. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 8A. The well will be installed in conjunction with Cell No. 8A construction. The well will be abandoned in conjunction with Cell No. 10 construction. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 20 of 26 Monitoring Location Proposed Monitoring Well Location and Justification GW-22 (proposed) Proposed downgradient well that will intersect the water table south of Cell No. 8A. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 8A. The well will be installed in conjunction with Cell No. 8A construction. The well will be abandoned in conjunction with Cell No. 10 construction. GW-23 (proposed) Proposed sidegradient well that will intersect water table west of Cell No. 9. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 9. The well will be installed in conjunction with Cell No. 9 construction. GW-24 (proposed) Proposed downgradient well that will intersect the water table south of Cell No. 9. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 9. The well will be installed in conjunction with Cell No. 9 construction. GW-25 (proposed) Proposed downgradient well that will intersect the water table south of Cell No. 9. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 9. The well will be installed in conjunction with Cell No. 9 construction. GW-26 (proposed) Proposed downgradient well that will intersect the water table south of Cell No. 10. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 10. The well will be installed in conjunction with Cell No. 10 construction. GW-27 (proposed) Proposed downgradient well that will intersect the water table south of Cell No. 10. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 10. The well will be installed in conjunction with Cell No. 10 construction. GW-28 (proposed) Proposed downgradient well that will intersect the water table south of Cell No. 7A. The well location is based on the local southeastern groundwater flow direction. The well location will intersect groundwater flow from Cell No. 7A. The well will be installed in conjunction with Cell No. 7A construction. 4.1.4 Monitoring Well Depths and Screened Intervals The depth of the proposed groundwater monitoring wells will be designed to monitor the uppermost aquifer present at the site. The wells will monitor either: 1) the residual soils and/or the partially weathered rock if a sufficient saturated thickness of the aquifer exists above the depth of auger refusal; or 2) the uppermost water-bearing bedrock fractures if the water table is in the bedrock unit. Actual well depths may be adjusted during well installation based on field conditions (i.e., depth to water, depth to bedrock fractures). 4.1.5 Spacing and Number of New Monitoring Wells The proposed new downgradient monitoring well locations were selected to intercept groundwater downgradient from Phase 4. Areas where groundwater flow is converging (i.e., surface drainage features) and proposed sump locations were targeted for monitoring (Figures 8, 9, and 10 of the DHR). The spacing of the proposed new wells is approximately 300 to 600 feet, which is consistent with the spacing of the existing monitoring wells at the facility. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 21 of 26 The number of new groundwater monitoring wells (sixteen) located in downgradient and sidegradient positions to Phase 4 is sufficient to provide representative groundwater quality samples of the groundwater in the uppermost aquifer flowing past the relevant point of compliance. The number and location of the new and existing downgradient groundwater monitoring wells are sufficient to detect groundwater contamination in the uppermost aquifer. 4.2 Surface Water Monitoring Plan There are two (2) surface water sampling locations associated with Phases 1 through 3 consisting of one (1) upgradient (SW-1) and one (1) downgradient (SW-2). Two (2) additional surface water locations (SW-3 and SW-4) will be added with the development of the first cell of Phase 4. New upgradient location SW-3 will be located upstream of Phase 4 and the eastward flowing tributary to Cub Creek near the southern facility boundary. Location SW-4 will be a new downstream location of Phase 4 along the eastward flowing tributary to Cub Creek near the southern facility boundary. These resulting four (4) locations are sufficient to monitor the upgradient (SW-1 and SW-3) and downgradient (SW-2 and SW-4) surface water for Phases 1 through 4. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 22 of 26 4.3 Water Quality Monitoring System The combined water quality monitoring system for Phases 1 through 4 is shown on Figure 2 in the WQMP titled Water Quality and Landfill Gas Monitoring Systems. During construction of Phase 4, wells will be systematically installed and abandoned as outlined in Section 4.1.3. Upon completion of Phase 4 (Cell 10), the monitoring system will include twenty-one (21) groundwater monitoring wells and four (4) surface water sampling locations. The water quality monitoring system for the site will include:  One (1) upgradient monitoring well (GW-1R);  twenty (20) downgradient/side-gradient monitoring wells (GW-2, GW-3, GW-4R, GW-5, GW-7, GW-8, GW-9, GW-10, GW-11, GW-12, GW-13, GW-14, GW-18, GW-19, GW-23, GW-24, GW-25, GW-26, GW-27, and GW-28).  two (2) upgradient surface water locations (SW-1 and SW-3);  two (2) downgradient surface water locations (SW-2 and SW-4). The schedule for new monitoring location installation will follow new landfill cell construction as shown on the following table. Phase 4 Cell Construction New Monitoring Location Installation Schedule Cell No. 7A GW-16, GW-17, GW-18, GW-28 Cell No. 7B GW-13, GW-14, GW-15 Cell No. 8A GW-21, GW-22 Cell No. 8B GW-19, GW-20 Cell No. 9 GW-23, GW-24, GW-25 Cell No. 10 GW-26, GW-27 Note: Surface water sampling locations SW-3 and SW-4 are to be installed with the development of the first cell of Phase 4. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 23 of 26 5.0 CONCLUSIONS Proposed Phase 4 landfill cell locations are on the lower elevations south of Phases 1 through 3. The Phase 4 area’s subsurface geology and hydrogeology are typical of Piedmont terrain in North Carolina. No unusual or unexpected geologic features were observed in the Phase 4 area. Groundwater flow at the site is radial from the upland areas. Shallow groundwater flows to the south and east across Phase 4 from recharge areas in the upland locations, and discharges to the on-site ponds and unnamed ephemeral stream south of Phase 4. Other than these natural features, there are no other observed groundwater receptors to this landfill phase. New and existing groundwater and surface water sampling locations were selected to effectively monitor the existing Phases (1, 2, and 3) and proposed Phase 4 cell areas. Sixteen (16) new downgradient well locations, one (1) new upgradient surface water location, and one (1) new downgradient surface water location around Phase 4 were selected based on the location of landfill components and groundwater flow directions. The new monitoring wells and surface water locations will be established in association with new cell construction in Phase 4. The landfill’s water quality monitoring system will include twenty-one (21) monitoring wells and four (4) surface water sampling locations upon completion of Phase 4 Cells 7- 10. The geotechnical aspects of the site are favorable for landfill development and will be detailed in a separate report prepared by BLE titled Report of Geotechnical Evaluation – Phase 4 (Cells No. 7-10) (BLE Project No. J21-1003-81B). Considerations and design requirements to form a stable subgrade and perimeter earthwork slopes will be provided in BLE’s geotechnical report along with estimates of subgrade settlement. Low permeability surficial soils that could be used to construct a regulatory clay liner (k  1.0 x 10-7 cm/sec), or an alternative base soil liner or final cover cap (k  1.0 x 10-5 cm/sec), were encountered during our exploration in limited quantities. Careful selection and/or use of these clayey soils will be required during landfill cell development. The landfill subgrade design should maintain a minimum 4-foot post-settlement vertical separation between the bottom elevation of the base liner system and the elevations of the bedrock (Figure 6) and the February 2021- February 2022 seasonal high groundwater (Figure 9). If bedrock is removed by mechanical means during cell construction to levels below that shown on Figure 6, then the minimum required 4-foot post- settlement vertical separation should be maintained with the resulting bedrock level. Likewise, if bedrock is encountered during cell construction above the levels shown on Figure 6, then the minimum required post-settlement vertical separation should be provided for the actual bedrock level, unless the bedrock is removed. This Design Hydrogeologic Report was prepared to satisfy the requirements specified in the North Carolina Title 15A NCAC 13B .1623 (b). Based on the results of field and laboratory testing, it is our opinion that the Phase 4 study area is geologically and hydrogeologically suitable for municipal solid waste landfill cell development. A comprehensive Environmental Monitoring Plan is provided as two separate documents submitted under separate cover prepared by BLE titled Water Quality Monitoring Plan and Landfill Gas Monitoring Plan, which includes procedures and locations for groundwater, surface water, and landfill gas monitoring for landfill Phases 1, 2, 3, and 4 in accordance with North Carolina 15A NCAC 13B .0601, and .1630 through Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 24 of 26 .1637 (groundwater), 15A NCAC 13B .1626(12)(c) (leachate), 15A NCAC 13B .0602 (surface water), and 15A NCAC 13B Rule .1626(4) (landfill gas). Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 25 of 26 6.0 ANNOTATED BIBLIOGRAPHY Bouwer, H. and Rice, R.C., 1976, "A slug test method for determining hydraulic conductivity of unconfined aquifers with completely or partially penetrating wells," Water Resources Research, Vol. 12, No. 3, pp. 423-428. - Slug testing data reduction procedures. Brown, M.B., and others (compilers), 1985, Geologic Map of North Carolina: NCDNRCD, scale 1:500,000. - General geologic setting and fault locations. Bunnell-Lammons Engineering, Inc., November 8, 2000 (revised August 20, 2003), Addendum to Site Hydrogeologic Report – Dawes Tract, Upper Piedmont Regional Landfill, BLE Job Number J99- 1003-16. - Site hydrogeologic report for an addendum to the Dawes Tract the landfill. Bunnell-Lammons Engineering, Inc., June 5, 2002 (revised September 27, 2002), Design Hydrogeologic Report, Phase 2 (Cells No. 1B-4B), Upper Piedmont Regional Landfill, BLE Job Number J01- 1003-24. - Design hydrogeologic report for Phase 2 at the landfill. Bunnell-Lammons Engineering, Inc., May 7, 2007 (revised May 1, 2009), Design Hydrogeologic Report, Phase 3 (Cells No. 5-6), Upper Piedmont Regional Landfill, BLE Job Number J06-1003-50. - Design hydrogeologic report for Phase 3 at the landfill. De Boer, J., and Snider, F.C., 1979, "Magnetic and chemical variations of Mesozoic diabase dikes from eastern North America: Evidence for a hotspot in the Carolinas?"; Geological Society of America Bulletin, Part 1, Vol. 90, pp. 185-198. - Regional diabase dike locations and trends. Fetter, C.W., 1994, Applied Hydrogeology: Merrill Publishing Company, Columbus, Ohio. - Basic hydrogeologic principles and estimates of effective porosity in soils. Glover, III, L., and Sinha, A.K., 1973, “The Virgilina Deformation, A Late Precambrian(?) Orogenic Event in the Central Piedmont of Virginia and North Carolina,” American Journal of Science, Vol. 273-A, pp. 234-251. - Local geologic setting. Harris, C.W., and Glover, III, L., (Leaders), 1985, “The Virgilina Deformation: Implications of Stratigraphic Correlation in the Carolina Slate Belt,” Field Trip Guide, Carolina Geological Society, Durham, NC (November 16-17, 1985), pp. 32-43. - Local geologic setting. Horton, J.W. and Zullo, V.A., 1991, The Geology of the Carolinas: Carolina Geological Society fifteenth anniversary volume: The University of Tennessee Press, Knoxville, TN. - General geologic setting. Koerner, R.M., 1998, Designing with Geosynthetics, Printice Hall. - Liner interface sliding and stability analysis. Design Hydrogeologic Report – Phase 4 (Cells No. 7-10) July 7, 2023 Upper Piedmont Regional MSW Landfill – Person Co., NC BLE Project Number J21-1003-81 26 of 26 Kruseman, G.P., and deRidder, N.A., 1989, Analysis and Evaluation of Pumping Test Data: Publication 47, International Institute for Land Reclamation and Improvement, Wageningen, The Netherlands. - Estimates of effective porosity in fractured bedrock. Law Engineering, Inc., January 29, 1996 (revised May 7, 1996), Design Hydrogeologic Report, Phase 1 (Cells 1A, 2A, 3A, and 4), Upper Piedmont Regional Landfill, Person County, North Carolina, Law Engineering Project Number 30290-5-6113.03. - Design hydrogeologic report for Phase 1 at the landfill. Martin, R.E., 1987, “Settlement of Residential Soils,” ASCE, Geotechnical Special Publication No. 9. - Settlement Analysis. Petersen MD, Shumway AM, Powers PM, et al. The 2018 update of the US National Seismic Hazard Model: Overview of model and implications. Earthquake Spectra. 2020;36(1):5-41. doi:10.1177/8755293019878199 - Seismic impact zones Richardson, G.N., 1998, “Design of Waste Containment Liner and Final Closure Systems,” ASCE Seminar, Nashville, TN. - Design analysis for landfills. Richardson, G.N., Kavazanjion, E. Jr., and Matasovic, N., 1995, “RCRA Subtitle D (258) Seismic Design Guidance for Municipal Solid Waste Landfill Facilities,” USEPA. - Guidance document for seismic design of landfills. Robinson, E.S., Poland, P.V., Glover, III, L., and Speer, J.A., 1985, “Some Effects of Regional Metamorphism and Geologic Structure on Magnetic Anomalies over the Carolina Slate Belt near Roxboro, North Carolina,” in W.J. Hinze (ed.), The Utility of Regional Gravity and Magnetic Anomaly Maps; Society of Exploratory Geophysicist, pp. 320-324. - Local geologic setting. Stucky, J.L., North Carolina: Its Geology and Mineral Resources, Department of Conservation and Development, Raleigh, North Carolina. - Regional geology and topographic description. U.S. Department of Agriculture (USDA), Version 25 September, 2022, Soil Survey of Person County, North Carolina. Person County Soil Conservation Service. - Soil survey of the area around the site. Wilson, B.V., 1988, “Evaluation of In-situ, Testing of Residual Soils and Prediction of Settlement,” Masters Thesis, NCSU, Department of Civil Engineering. - Settlement Analysis TABLES TABLE 1 MONITORING WELL, PIEZOMETER, AND BORING SURVEY INFORMATION Upper Piedmont Regional MSW Landfill - Phase 4 DHR Person County, North Carolina BLE Project Number J21-1003-81 Soil Test Well/Ground TOC Status of Boring Piezometer Elevation Elevation Northing Easting Well/Piezometer -GW-1 721.35 724.15 936,823.46 2,048,512.07 Present -GW-1R 721.74 724.71 936,812.23 2,048,507.46 Present -GW-2 598.00 600.39 935,854.57 2,050,409.73 Present -GW-3 560.12 562.55 936,356.10 2,050,741.04 Present -GW-4 558.12 560.97 936,623.14 2,050,740.86 Abandoned -GW-4R 558.83 561.61 936,628.25 2,050,744.41 Present -GW-5 559.40 562.13 936,816.96 2,050,730.04 Present -GW-6 626.70 629.29 936,193.39 2,049,092.51 Present -GW-7 581.51 584.06 937,234.97 2,050,657.76 Present -GW-8 634.07 636.91 937,687.07 2,050,269.39 Present -GW-9 609.33 612.26 938,039.79 2,050,061.22 Present -GW-10 616.51 619.14 938,033.04 2,049,689.39 Present -GW-11 613.13 616.35 938,056.15 2,049,313.72 Present -GW-12 606.33 609.34 938,076.46 2,048,974.58 Present -PZ-1c 645.35 647.11 937,599.11 2,049,658.88 Abandoned -PZ-2ab 612.64 615.67 938,662.20 2,049,865.24 Present -PZ-3ab 618.08 621.11 936,926.75 2,049,500.55 Abandoned -PZ-3Rab 618.47 620.67 936,926.39 2,049,510.33 Abandoned -PZ-4a 612.59 615.54 937,826.00 2,050,192.19 Abandoned -PZ-4b 612.18 615.22 937,827.20 2,050,200.72 Abandoned -PZ-5c 632.30 635.10 936,385.23 2,049,134.23 Abandoned -PZ-6ab 671.01 674.04 937,433.15 2,049,142.76 Abandoned -PZ-6c 671.13 672.58 937,422.52 2,049,139.75 Abandoned -PZ-7c 634.47 637.04 936,181.05 2,048,637.39 Present B-8 -670.54 -937,396.98 2,048,746.26 Abandoned -PZ-9c 720.60 722.30 936,804.73 2,048,554.96 Present -PZ-10ab 689.11 692.66 937,004.10 2,048,877.17 Abandoned -PZ-10c 689.21 692.27 937,014.35 2,048,874.30 Abandoned -PZ-11a 622.06 623.90 936,132.59 2,049,004.31 Present -PZ-12ab 611.17 613.39 936,837.72 2,050,107.36 Abandoned -PZ-12c 611.36 614.12 936,839.18 2,050,099.60 Abandoned B-13 -644.41 -935,752.00 2,047,064.99 Abandoned -PZ-14c 625.5 626.88 935,501.25 2,047,533.29 Present -PZ-15b 598.27 601.42 936,200.37 2,050,136.49 Abandoned -PZ-15c 599.42 602.50 936,201.09 2,050,125.76 Abandoned -PZ-16c 631.00 633.75 935,768.38 2,048,136.64 Present B-17 -628.36 -935,792.60 2,049,034.10 Abandoned B-18 -618.50 -935,513.46 2,048,456.40 Abandoned -PZ-19ab 634.13 637.27 936,156.20 2,049,374.45 Abandoned -PZ-19c 634.29 637.38 936,153.90 2,049,365.47 Abandoned -PZ-20ab 607.93 610.97 935,499.17 2,049,381.29 Present -PZ-21ab 573.73 576.26 934,347.30 2,049,471.63 Present -PZ-22c 603.21 606.32 935,088.58 2,049,437.90 Present B-23 -603.64 -938,347.54 2,050,799.03 Abandoned -PZ-24ab 601.04 604.01 937,509.40 2,051,107.15 Present -PZ-25a 593.48 596.40 934,090.10 2,051,013.91 Abandoned B-26 -574.24 -937,641.66 2,050,739.07 Abandoned -PZ-27ab 584.03 587.00 938,180.92 2,050,403.00 Present -PZ-28 645.28 648.59 939,153.33 2,048,645.84 Present -PZ-29b 601.15 604.03 935,272.21 2,051,403.91 Abandoned -PZ-30ab 592.78 595.61 935,349.66 2,050,637.24 Present -PZ-31a 591.04 592.99 934,886.52 2,051,296.80 Abandoned -PZ-31b 591.08 594.11 934,890.31 2,051,296.68 Abandoned -PZ-32ab 601.85 604.81 934,227.01 2,051,431.26 Abandoned -PZ-33ab 585.13 588.21 933,820.87 2,051,441.41 Abandoned -PZ-34ab 631.11 634.07 937,917.11 2,049,355.72 Abandoned -PZ-35a 621.95 625.47 934,276.04 2,050,454.00 Abandoned B-36 -619.24 -938,529.82 2,049,217.94 Abandoned -PZ-37ab 598.81 601.92 938,642.40 2,050,161.60 Present B-38 -615.38 -938,776.97 2,050,504.17 Abandoned Tab 1 - Survey Data UPRLF-DHR Cells 7-10 Prepared By: MSP/RLB Checked By: TJD/MSP Soil Test Well/Ground TOC Status of Boring Piezometer Elevation Elevation Northing Easting Well/Piezometer -PZ-39ab 611.22 614.07 936,611.18 2,049,701.90 Abandoned -PZ-39c 611.27 612.69 936,615.28 2,049,714.82 Abandoned -PZ-40ab 585.60 588.25 937,409.16 2,050,395.52 Abandoned -PZ-41a 611.96 614.47 938,202.15 2,048,610.71 Abandoned -PZ-42a 553.84 555.68 936,300.86 2,050,903.98 Present -PZ-43c 612.33 613.98 936,778.54 2,049,967.60 Abandoned -PZ-44ab 605.82 608.89 937,014.49 2,049,910.85 Abandoned -PZ-45ab 611.74 614.17 936,909.42 2,049,646.06 Abandoned -PZ-46ab 603.57 606.10 936,565.30 2,050,002.54 Abandoned -PZ-47ab 623.43 625.73 936,713.74 2,049,472.60 Abandoned -PZ-48ab 614.40 616.15 936,410.37 2,049,859.87 Abandoned B-49 -618.74 -936,768.03 2,049,712.61 Abandoned -PZ-50ab 627.84 630.46 936,289.87 2,049,667.15 Abandoned -PZ-51b 610.07 612.35 936,232.27 2,049,988.79 Abandoned -PZ-52c 635.15 636.61 936,177.27 2,049,534.83 Abandoned B-53 -625.74 -936,386.80 2,049,447.58 Abandoned -PZ-54ab 618.83 621.17 936,142.62 2,049,836.95 Abandoned -PZ-55a 601.56 603.26 936,575.05 2,050,209.26 Abandoned -PZ-55b 601.94 604.34 936,580.76 2,050,202.79 Abandoned B-56 -582.32 -935,998.08 2,050,176.61 Abandoned -PZ-57ab 586.19 587.74 936,609.17 2,050,474.74 Abandoned -PZ-58c 599.21 601.07 935,987.43 2,050,020.76 Abandoned -PZ-59ab 576.84 578.08 935,998.46 2,050,487.45 Abandoned -PZ-60c 576.30 577.99 936,260.49 2,050,257.45 Abandoned -PZ-61a 558.04 560.04 936,346.37 2,050,745.80 Abandoned -PZ-61c 559.69 560.94 936,332.40 2,050,710.87 Abandoned -PZ-62ab 587.90 590.45 935,753.04 2,050,218.38 Abandoned -PZ-63c 642.09 643.19 937,390.97 2,049,611.30 Abandoned -PZ-64ab 608.24 610.78 937,249.98 2,049,834.01 Abandoned -PZ-64c 607.88 609.17 937,247.26 2,049,838.69 Abandoned -PZ-65ab 588.18 590.68 937,194.14 2,050,339.92 Abandoned B-66 -587.16 -936,899.40 2,050,430.11 Abandoned -PZ-67ab 563.48 566.00 936,863.89 2,050,621.29 Abandoned -PZ-67c 563.45 565.08 936,871.38 2,050,616.56 Abandoned B-68 -609.0 -935,260.86 2,049,039.32 Abandoned -PZ-69ab 595.6 599.06 935,257.95 2,048,591.27 Present B-70 -612.3 -935,238.68 2,047,998.16 Abandoned B-71 -590.0 -935,000.01 2,049,206.58 Abandoned -PZ-72ab 599.9 601.93 934,973.25 2,048,885.80 Present -PZ-73c 697.92 701.07 936,900.13 2,048,804.65 Abandoned -PZ-74c 685.97 688.70 936,746.48 2,048,815.67 Abandoned B-75 -676.54 -937,267.86 2,048,941.81 Abandoned -PZ-76c 678.85 681.79 937,253.61 2,048,871.00 Abandoned -PZ-77c 678.63 681.48 937,428.51 2,048,923.20 Abandoned B-78 -664.05 -937,313.12 2,049,156.28 Abandoned B-79 -658.22 -937,367.34 2,049,294.55 Abandoned -PZ-80c 643.15 646.12 937,260.31 2,049,484.73 Abandoned B-81 -662.08 -937,189.71 2,049,068.72 Abandoned -PZ-82 662.41 664.78 936,578.65 2,048,835.66 Abandoned -PZ-83c 650.55 653.45 936,608.70 2,048,975.46 Abandoned B-84 -634.83 -936,528.40 2,049,162.07 Abandoned -PZ-85c 634.56 637.51 936,782.26 2,049,226.52 Abandoned -PZ-86c 661.39 664.34 936,906.44 2,049,051.30 Abandoned -PZ-87 658.91 662.31 936,935.29 2,049,183.29 Abandoned -PZ-88c 652.55 655.70 937,072.37 2,049,196.38 Abandoned B-89 -646.95 -936,701.76 2,049,083.67 Abandoned B-90 -683.47 -936,806.57 2,048,880.54 Abandoned B-91 -649.06 -937,248.54 2,049,298.07 Abandoned B-92 -670.95 -937,497.13 2,048,781.94 Abandoned -PZ-101ab 610.95 614.30 938,026.62 2,049,983.04 Abandoned -PZ-102b 624.60 627.79 937,806.21 2,049,982.40 Abandoned B-103 -618.74 -937,703.90 2,050,057.38 Abandoned B-104 -609.23 -937,545.92 2,050,079.48 Abandoned -PZ-105c 637.01 640.04 937,686.76 2,049,815.81 Abandoned B-106 -649.94 -937,671.37 2,049,364.53 Abandoned -PZ-107ab 631.40 634.54 937,849.25 2,049,777.86 Abandoned B-108 -640.84 -937,719.98 2,049,526.33 Abandoned Tab 1 - Survey Data UPRLF-DHR Cells 7-10 Prepared By: MSP/RLB Checked By: TJD/MSP Soil Test Well/Ground TOC Status of Boring Piezometer Elevation Elevation Northing Easting Well/Piezometer -PZ-109c 658.63 661.93 937,658.29 2,049,188.74 Abandoned -PZ-110ab 621.58 624.75 937,999.15 2,049,206.42 Abandoned B-111 -626.22 -937,893.57 2,049,510.69 Abandoned B-112 -638.15 -937,818.50 2,049,366.30 Abandoned -PZ-113ab 669.03 672.18 937,456.31 2,049,179.71 Abandoned -PZ-114b 658.49 660.79 937,488.30 2,049,372.54 Abandoned B-115 -625.35 -937,550.59 2,049,937.31 Abandoned -PZ-116c 602.76 606.18 937,370.13 2,049,983.43 Abandoned B-117 -595.34 -937,400.42 2,050,178.49 Abandoned -PZ-118c 589.84 593.34 937,287.95 2,050,327.52 Abandoned -PZ-119ab 584.23 586.50 937,261.91 2,050,506.46 Abandoned -PZ-120b 598.05 601.03 937,578.55 2,050,308.04 Abandoned -PZ-121b 612.87 616.32 938,025.44 2,049,565.31 Abandoned -PZ-122c 658.07 661.03 937,743.99 2,048,944.66 Abandoned B-123 -666.49 -937,632.56 2,049,008.48 Abandoned -PZ-124c 676.79 679.54 937,441.07 2,048,990.24 Abandoned B-125 -628.10 -936,266.02 2,048,969.38 Abandoned -PZ-126B 629.78 632.25 936,087.25 2,049,149.78 Present B-127 -616.63 -935,940.59 2,048,878.25 Abandoned -PZ-128B 627.01 629.46 935,973.58 2,049,016.06 Present -PZ-129B 632.42 635.11 935,938.12 2,049,240.22 Present B-130 -623.88 -935,910.17 2,049,400.83 Abandoned -PZ-131AB 616.06 618.60 935,888.94 2,049,591.10 Present -PZ-132B 620.26 622.66 935,784.68 2,048,904.99 Present -PZ-133C 627.01 629.31 935,803.12 2,049,179.07 Present -PZ-133B 627.64 630.34 935,805.43 2,049,173.42 Present -PZ-134AB 617.34 619.94 935,787.95 2,049,409.19 Present -PZ-135B 611.85 614.25 935,715.27 2,049,509.66 Present -PZ-136B 600.32 602.67 935,770.97 2,049,813.60 Present -PZ-137B 612.33 614.66 935,499.78 2,048,971.49 Present -PZ-138B 608.67 611.32 935,494.91 2,049,183.51 Present -PZ-139C 605.75 608.30 935,496.49 2,049,515.52 Present -PZ-140B 604.28 606.60 935,456.53 2,049,806.35 Present -PZ-141B 592.51 594.14 935,492.70 2,050,017.14 Present -PZ-142B 588.57 590.92 935,611.80 2,050,138.05 Present -PZ-143B 583.40 585.75 935,472.70 2,050,279.46 Present -PZ-144B 611.92 614.45 935,269.70 2,048,884.46 Present -PZ-145B 604.50 606.62 935,286.79 2,049,171.74 Present -PZ-146AB 599.35 601.84 935,278.11 2,049,348.26 Present -PZ-147B 614.25 616.69 935,275.47 2,049,608.34 Present -PZ-148B 606.96 609.06 935,331.14 2,049,785.76 Present -PZ-149B 596.17 598.89 935,277.44 2,050,002.56 Present -PZ-150B 593.44 595.34 935,256.65 2,050,198.41 Present -PZ-151B 593.62 596.14 934,970.39 2,049,074.61 Present -PZ-152B 597.11 599.61 935,020.81 2,049,319.32 Present -PZ-153B 599.36 602.12 934,989.48 2,049,521.50 Present -PZ-154B 595.40 597.40 934,961.46 2,049,714.41 Present -PZ-155B 592.61 595.52 934,964.60 2,049,902.84 Present -PZ-156A 593.90 596.48 934,909.11 2,050,078.69 Present -PZ-156B 594.05 596.30 934,911.48 2,050,082.84 Present -PZ-157B 588.33 591.18 934,888.83 2,049,113.74 Present -PZ-158B 587.26 589.70 934,749.99 2,049,051.36 Present -PZ-159B 592.09 594.23 934,725.92 2,049,263.11 Present -PZ-160B 593.80 595.90 934,739.30 2,049,452.76 Present -PZ-161B 592.09 594.71 934,791.46 2,049,689.05 Present -PZ-162C 594.58 597.03 934,738.84 2,049,925.61 Present NOTES: 1. Bold borings represent those in the Phase 3 Cell area 2. Measurements are in feet; elevations are relative to mean sea level 3. TOC = Top Of Casing 4. Surveying of all location excluding GWC-11 and GWC-12 was performed by Wright & Fields of Troy, NC and Donaldson, Garrett, & Assoc., of Charlotte, NC 5. Groundwater monitoring wells GWC-11 and GWC-12 were installed after the completion of field work for the Phase 4 DHR. 6. Surveying of GWC-11 and GWC-12 was performed by WithersRavenel of Cary, NC. Tab 1 - Survey Data UPRLF-DHR Cells 7-10 Prepared By: MSP/RLB Checked By: TJD/MSP TABLE 2 MONITORING WELL AND PIEZOMETER CONSTRUCTION DETAILS Upper Piedmont Regional MSW Landfill - Phase 4 DHR Person County, North Carolina BLE Project Number J21-1003-81 Soil Test Well/Ground TOC Auger Auger Bedrock Drilling Screened Screened Status of Boring Piezometer Elev.Elev.Refusal Depth Refusal Elev.Depth Interval Depth Interval Elevation Well/Piezometer -GW-1 721.35 724.15 NA NA 23.0 -33.0 15.0 -30.0 706.4 -691.4 Present -GW-1R 721.74 724.71 21.0 700.7 21.0 -60.4 45.2 -60.2 676.6 -661.6 Present -GW-2 598.00 600.39 NA NA 27.5 -44.0 28.5 -43.5 569.5 -554.5 Present -GW-3 560.12 562.55 13.0 547.1 13.0 -38.0 22.0 -37.0 538.1 -523.1 Present -GW-4 558.12 560.97 8.0 550.1 8.0 -43.0 27.0 -42.0 531.1 -516.1 Abandoned -GW-4R 558.83 561.61 6.5 552.3 6.5 -43.6 27.2 -42.2 531.6 -516.6 Present -GW-5 559.40 562.13 NA NA 4.0 -20.0 4.5 -19.5 554.9 -539.9 Present -GW-6 626.70 629.29 5.0 621.7 5.0 -25.5 10.5 -25.5 616.2 -601.2 Present -GW-7 581.51 584.06 16.0 565.5 16.0 -30.0 10.7 -25.7 570.8 -555.8 Present -GW-8 634.07 636.91 44.5 589.6 44.5 -55.0 39.9 -54.9 594.2 -579.2 Present -GW-9 609.33 612.26 23.0 586.3 23.0 -34.0 15.2 -30.2 594.2 -579.2 Present -GW-10 616.51 619.14 22.0 594.5 22.0 -35.0 12.8 -27.8 603.7 -588.7 Present -GW-11 613.13 616.35 14.0 599.1 14.0 -29.5 14.5 -29.5 598.6 -583.6 Present -GW-12 606.33 609.34 21.5 584.8 21.5 -30.0 15.0 -30.0 591.3 -576.3 Present -PZ-1c 645.35 647.11 10.0 635.4 10.0 -28.9 18.9 -28.9 626.5 -616.5 Abandoned -PZ-2ab 612.64 615.67 9.5 603.1 NA 4.5 -9.5 608.1 -603.1 Present -PZ-3ab 618.08 621.11 15.4 602.7 NA 10.4 -15.4 607.7 -602.7 Abandoned -PZ-3Rab 618.47 620.67 10.0 608.5 NA 4.7 -9.7 613.8 -608.8 Abandoned -PZ-4a 612.59 615.54 NA NA NA 18.3 -28.3 594.3 -584.3 Abandoned -PZ-4b 612.18 615.22 54.5 557.7 NA 44.0 -54.0 568.2 -558.2 Abandoned -PZ-5c 632.30 635.10 14.5 617.8 14.5 -35.6 14.5 -35.6 617.8 -596.7 Abandoned -PZ-6ab 671.01 674.04 17.0 654.0 NA 12.0 -17.0 659.0 -654.0 Abandoned -PZ-6c 671.13 672.58 17.0 654.1 17.9 -28.9 17.9 -28.9 653.2 -642.2 Abandoned -PZ-7c 634.47 637.04 9.0 625.5 9.0 -25.0 9.0 -25.0 625.5 -609.5 Present B-8 -670.54 -3.0 667.5 NA NA NA Abandoned -PZ-9c 720.60 722.30 7.5 713.1 7.5 -27.9 7.5 -27.9 713.1 -692.7 Present -PZ-10ab 689.11 692.66 12.2 676.9 NA 7.2 -12.2 681.9 -676.9 Abandoned -PZ-10c 689.21 692.27 16 673.2 15.7 -23.7 15.7 -23.7 673.5 -665.5 Abandoned -PZ-11a 622.06 623.90 NA NA NA 2.3 -3.3 619.8 -618.8 Present -PZ-12ab 611.17 613.39 18.0 593.2 NA 8.0 -18.0 603.2 -593.2 Abandoned -PZ-12c 611.36 614.12 17.0 594.4 17.0 -28.7 17.0 -28.7 594.4 -582.7 Abandoned B-13 -644.41 -5.0 639.4 NA NA NA Abandoned -PZ-14c 625.50 626.88 8.0 617.5 8.0 -25.5 8.0 -25.5 617.5 -600.0 Present -PZ-15b 598.27 601.42 9.5 588.8 NA 4.5 -9.5 593.8 -588.8 Abandoned -PZ-15c 599.42 602.50 8.2 591.2 8.2 -23.8 8.2 -23.8 591.2 -575.6 Abandoned -PZ-16c 631.00 633.75 15.6 615.4 15.6 -30.1 19.8 -29.8 611.2 -601.2 Present B-17 -628.36 -3.0 625.4 NA NA NA Abandoned B-18 -618.50 -5.5 613.0 NA NA NA Abandoned -PZ-19ab 634.13 637.27 31.0 603.1 NA 20.8 -30.8 613.3 -603.3 Abandoned -PZ-19c 634.29 637.38 24.0 610.3 24.5 -50.7 24.5 -50.7 609.8 -583.6 Abandoned -PZ-20ab 607.93 610.97 23.0 584.9 NA 12.5 -22.5 595.4 -585.4 Present -PZ-21ab 573.73 576.26 12.5 561.2 NA 7.5 -12.5 566.2 -561.2 Present -PZ-22c 603.21 606.32 14.0 589.2 14.0 -34.7 14.0 -34.7 589.2 -568.5 Present B-23 -603.64 -8.0 595.6 NA NA NA Abandoned -PZ-24ab 601.04 604.01 30.7 570.3 NA 20.7 -30.7 580.3 -570.3 Present -PZ-25a 593.48 596.40 50.0 543.5 NA 24.0 -34.0 569.5 -559.5 Abandoned B-26 -574.24 -3.0 571.2 NA NA NA Abandoned -PZ-27ab 584.03 587.00 8.5 575.5 NA 3.5 -8.5 580.5 -575.5 Present -PZ-28 645.28 648.59 16.0 629.3 NA 5.6 -15.6 639.7 -629.7 Present -PZ-29b 601.15 604.03 20.0 581.2 NA 10.0 -20.0 591.2 -581.2 Abandoned -PZ-30ab 592.78 595.61 23.0 569.8 NA 13.0 -23.0 579.8 -569.8 Present -PZ-31a 591.04 592.99 NA NA NA 2.8 -7.8 588.2 -583.2 Abandoned -PZ-31b 591.08 594.11 27.0 564.1 NA 17.0 -27.0 574.1 -564.1 Abandoned -PZ-32ab 601.85 604.81 23.5 578.4 NA 13.5 -23.5 588.4 -578.4 Abandoned -PZ-33ab 585.13 588.21 19.0 566.1 NA 9.0 -19.0 576.1 -566.1 Abandoned -PZ-34ab 631.11 634.07 20.0 611.1 NA 10.0 -20.0 621.1 -611.1 Abandoned -PZ-35a 621.95 625.47 >55.0 <567.0 NA 27.0 -37.0 595.0 -585.0 Abandoned B-36 -619.24 -3.0 616.2 NA NA NA Abandoned -PZ-37ab 598.81 601.92 13.0 585.8 NA 7.5 -12.5 591.3 -586.3 Present B-38 -615.38 -4.5 610.9 NA NA NA Abandoned -PZ-39ab 611.22 614.07 16.0 595.2 NA 6.0 -16.0 605.2 -595.2 Abandoned -PZ-39c 611.27 612.69 21.5 589.8 21.5 -36.5 21.5 -36.5 589.8 -574.8 Abandoned -PZ-40ab 585.60 588.25 13.0 572.6 NA 7.5 -12.5 578.1 -573.1 Abandoned -PZ-41a 611.96 614.47 NA NA NA 3.5 -4.5 608.5 -607.5 Abandoned -PZ-42a 553.84 555.68 NA NA NA 2.2 -3.2 551.6 -550.6 Present -PZ-43c 612.33 613.98 18.0 594.3 18.0 -33.0 18.0 -33.0 594.3 -579.3 Abandoned -PZ-44ab 605.82 608.89 12.0 593.8 NA 1.5 -11.5 604.3 -594.3 Abandoned -PZ-45ab 611.74 614.17 9.5 602.2 NA 4.0 -9.0 607.7 -602.7 Abandoned -PZ-46ab 603.57 606.10 11.8 591.8 NA 6.3 -11.3 597.3 -592.3 Abandoned -PZ-47ab 623.43 625.73 8.5 614.9 NA 5.0 -8.5 618.4 -614.9 Abandoned -PZ-48ab 614.40 616.15 28.5 585.9 NA 18.0 -28.0 596.4 -586.4 Abandoned B-49 -618.74 -6.0 612.7 NA NA NA Abandoned -PZ-50ab 627.84 630.46 15.5 612.3 NA 5.0 -15.0 622.8 -612.8 Abandoned -PZ-51b 610.07 612.35 36.5 573.6 NA 26.0 -36.0 584.1 -574.1 Abandoned -PZ-52c 635.15 636.61 19.5 615.7 19.5 -34.5 19.5 -34.5 615.7 -600.7 Abandoned B-53 -625.74 -13.0 612.7 NA NA NA Abandoned -PZ-54ab 618.83 621.17 32.0 586.8 NA 20.0 -30.0 598.8 -588.8 Abandoned -PZ-55a 601.56 603.26 NA NA NA 18.0 -28.0 583.6 -573.6 Abandoned -PZ-55b 601.94 604.34 59.0 542.9 NA 53.5 -58.5 548.4 -543.4 Abandoned B-56 -582.32 -9.5 572.8 NA NA NA Abandoned -PZ-57ab 586.19 587.74 29.0 557.2 NA 18.0 -28.0 568.2 -558.2 Abandoned -PZ-58c 599.21 601.07 6.5 592.7 6.5 -21.5 6.5 -21.5 592.7 -577.7 Abandoned -PZ-59ab 576.84 578.08 8.0 568.8 NA 1.0 -6.0 575.8 -570.8 Abandoned -PZ-60c 576.30 577.99 10.0 566.3 10.0 -25.0 10.0 -25.0 566.3 -551.3 Abandoned -PZ-61a 558.04 560.04 NA NA NA 1.0 -6.0 557.0 -552.0 Abandoned -PZ-61c 559.69 560.94 19.0 540.7 19.0 -34.0 19.0 -34.0 540.7 -525.7 Abandoned -PZ-62ab 587.90 590.45 16.0 571.9 NA 6.3 -16.3 581.6 -571.6 Abandoned -PZ-63c 642.09 643.19 8.5 633.6 8.5 -25.0 8.5 -25.0 633.6 -617.1 Abandoned -PZ-64ab 608.24 610.78 20.0 588.2 NA 10.0 -20.0 598.2 -588.2 Abandoned -PZ-64c 607.88 609.17 19.0 588.9 19.0 -39.0 19.0 -39.0 588.9 -568.9 Abandoned -PZ-65ab 588.18 590.68 6.0 582.2 NA 1.0 -6.0 587.2 -582.2 Abandoned B-66 -587.16 -8.0 579.2 NA NA NA Abandoned -PZ-67ab 563.48 566.00 11.5 552.0 NA 5.5 -10.5 558.0 -553.0 Abandoned Tab 2 - Borings UPRLF-DHR Cells 7-10 Prepared By: MSP/RLB Checked By: TJD/MSP Soil Test Well/Ground TOC Auger Auger Bedrock Drilling Screened Screened Status of Boring Piezometer Elev.Elev.Refusal Depth Refusal Elev.Depth Interval Depth Interval Elevation Well/Piezometer -PZ-67c 563.45 565.08 8.5 555.0 8.5 -27.5 8.5 -27.5 555.0 -536.0 Abandoned B-68 -609.00 -12.0 597.0 NA NA NA Abandoned -PZ-69ab 595.60 599.06 11.0 584.6 NA 4.9 -9.9 590.7 -585.7 Present B-70 -612.30 -4.0 608.3 NA NA NA Abandoned B-71 -590.00 -5.0 585.0 NA NA NA Abandoned -PZ-72ab 599.90 601.93 18.5 581.4 NA 8.2 -18.2 591.7 -581.7 Present -PZ-73c 697.92 701.07 8.0 689.9 8.0 -14.5 9.2 -14.2 688.7 -683.7 Abandoned -PZ-74c 685.97 688.70 8.2 677.8 8.2 -24.7 14.4 -24.4 671.6 -661.6 Abandoned B-75 -676.54 -6.0 670.5 NA NA NA Abandoned -PZ-76c 678.85 681.79 2.5 676.4 2.5 -10.0 4.7 -9.7 674.2 -669.2 Abandoned -PZ-77c 678.63 681.48 9.8 668.8 9.8 -30.7 18.7 -28.7 659.9 -649.9 Abandoned B-78 -664.05 -6.0 658.1 NA NA NA Abandoned B-79 -658.22 -8.0 650.2 NA NA NA Abandoned -PZ-80c 643.15 646.12 8.0 635.2 8.0 -24.6 14.3 -24.3 628.9 -618.9 Abandoned B-81 -662.08 -3.0 659.1 NA NA NA Abandoned -PZ-82 662.41 664.78 20.0 642.4 NA 9.7 -19.7 652.7 -642.7 Abandoned -PZ-83c 650.55 653.45 9.1 641.5 9.1 -24.1 13.8 -23.8 636.8 -626.8 Abandoned B-84 -634.83 -4.0 630.8 NA NA NA Abandoned -PZ-85c 634.56 637.51 8.8 625.8 8.8 -25.0 14.7 -24.7 619.9 -609.9 Abandoned -PZ-86c 661.39 664.34 7.6 653.8 7.6 -20.2 9.9 -19.9 651.5 -641.5 Abandoned -PZ-87 658.91 662.31 24.5 634.4 NA 13.2 -23.2 645.7 -635.7 Abandoned -PZ-88c 652.55 655.70 9.5 643.1 9.5 -25.0 14.7 -24.7 637.9 -627.9 Abandoned B-89 -646.95 -9.5 637.5 NA NA NA Abandoned B-90 -683.47 -5.0 678.5 NA NA NA Abandoned B-91 -649.06 -13.0 636.1 NA NA NA Abandoned B-92 -670.95 -6.0 665.0 NA NA NA Abandoned -PZ-101ab 610.95 614.30 12.5 598.5 NA 7.0 -12.0 604.0 -599.0 Abandoned -PZ-102b 624.60 627.79 30.0 594.6 NA 19.3 -29.3 605.3 -595.3 Abandoned B-103 -618.74 -7.5 611.2 NA NA NA Abandoned B-104 -609.23 -10.3 598.9 NA NA NA Abandoned -PZ-105c 637.01 640.04 6.0 631.0 6.0 -25.0 11.1 -21.1 625.9 -615.9 Abandoned B-106 -649.94 -10.5 639.4 NA NA NA Abandoned -PZ-107ab 631.40 634.54 11.9 619.5 NA 6.9 -11.9 624.5 -619.5 Abandoned B-108 -640.84 -9.5 631.3 NA NA NA Abandoned -PZ-109c 658.63 661.93 5.0 653.6 5.0 -30.0 15.9 -25.9 642.7 -632.7 Abandoned -PZ-110ab 621.58 624.75 15.9 605.7 NA 5.9 -15.9 615.7 -605.7 Abandoned B-111 -626.22 -5.0 621.2 NA NA NA Abandoned B-112 -638.15 -6.0 632.2 NA NA NA Abandoned -PZ-113ab 669.03 672.18 16.0 653.0 NA 5.2 -15.2 663.8 -653.8 Abandoned -PZ-114b 658.49 660.79 53.0 605.5 NA 43.0 -53.0 615.5 -605.5 Abandoned B-115 -625.35 -3.0 622.4 NA NA NA Abandoned -PZ-116c 602.76 606.18 5.0 597.8 5.0 -20.0 14.1 -19.1 588.7 -583.7 Abandoned B-117 -595.34 -11.0 584.3 NA NA NA Abandoned -PZ-118c 589.84 593.34 6.0 583.8 6.0 -20.0 9.5 -19.5 580.3 -570.3 Abandoned -PZ-119ab 584.23 586.50 12.8 571.4 NA 7.8 -12.8 576.4 -571.4 Abandoned -PZ-120b 598.05 601.03 26.0 572.1 NA 15.8 -25.8 582.3 -572.3 Abandoned -PZ-121b 612.87 616.32 16.6 596.3 NA 11.6 -16.6 601.3 -596.3 Abandoned -PZ-122c 658.07 661.03 14.0 644.1 14.0 -30.0 19.7 -29.7 638.4 -628.4 Abandoned B-123 -666.49 -10.0 656.5 NA NA NA Abandoned -PZ-124c 676.79 679.54 10.0 666.8 10.0 -30.0 17.0 -27.0 659.8 -649.8 Abandoned B-125 -628.10 -6.0 622.1 NA NA NA Abandoned -PZ-126B 629.78 632.25 23.5 606.3 NA 17.5 -22.5 612.3 -607.3 Present B-127 -616.63 -8.5 608.1 NA NA NA Abandoned -PZ-128B 627.01 629.46 15.0 612.0 NA 8.5 -13.5 618.5 -613.5 Present -PZ-129B 632.42 635.11 18.8 613.59 NA 13.5 -18.5 618.9 -613.9 Present B-130 -623.88 -12.0 611.9 NA NA NA Abandoned -PZ-131AB 616.06 618.60 18.5 597.6 NA 13.0 -18.0 603.1 -598.1 Present -PZ-132B 620.26 622.66 28.5 591.8 NA 16.0 -26.0 604.3 -594.3 Present -PZ-133C 627.01 629.31 13.5 613.5 13.5 -23.5 17.0 -22.0 610.0 -605.0 Present -PZ-133B 627.64 630.34 13.5 614.1 NA 7.0 -12.0 620.6 -615.6 Present -PZ-134AB 617.34 619.94 22.0 595.3 NA 15.7 -20.7 601.6 -596.6 Present -PZ-135B 611.85 614.25 23.6 588.3 NA 18.0 -23.0 593.9 -588.9 Present -PZ-136B 600.32 602.67 13.5 586.8 NA 6.5 -11.5 593.8 -588.8 Present -PZ-137B 612.33 614.66 19.0 593.3 NA 13.0 -18.0 599.3 -594.3 Present -PZ-138B 608.67 611.32 29.0 579.7 NA 18.0 -28.0 590.7 -580.7 Present -PZ-139C 605.75 608.30 4.0 601.8 4.0 -14.5 9.0 -14.0 596.8 -591.8 Present -PZ-140B 604.28 606.60 35.0 569.3 NA 22.0 -32.0 582.3 -572.3 Present -PZ-141B 592.51 594.14 22.0 570.5 NA 16.0 -21.0 576.5 -571.5 Present -PZ-142B 588.57 590.92 20.0 568.6 NA 13.3 -18.3 575.3 -570.3 Present -PZ-143B 583.40 585.75 18.8 564.6 NA 13.5 -18.5 569.9 -564.9 Present -PZ-144B 611.92 614.45 18.5 593.4 NA 13.0 -18.0 598.9 -593.9 Present -PZ-145B 604.50 606.62 18.5 586.0 NA 13.0 -18.0 591.5 -586.5 Present -PZ-146AB 599.35 601.84 9.0 590.35 NA 3.3 -8.3 596.1 -591.1 Present -PZ-147B 614.25 616.69 29.5 584.8 NA 18.5 -28.5 595.8 -585.8 Present -PZ-148B 606.96 609.06 >40.0 -NA 28.5 -38.5 578.5 -568.5 Present -PZ-149B 596.17 598.89 18.5 577.7 NA 12.0 -17.0 584.2 -579.2 Present -PZ-150B 593.44 595.34 18.5 574.9 NA 13.0 -18.0 580.4 -575.4 Present -PZ-151B 593.62 596.14 18.5 575.1 NA 13.0 -18.0 580.6 -575.6 Present -PZ-152B 597.11 599.61 8.5 588.6 NA 3.0 -8.0 594.1 -589.1 Present -PZ-153B 599.36 602.12 33.5 565.9 NA 23.0 -33.0 576.4 -566.4 Present -PZ-154B 595.40 597.40 23.5 571.9 NA 17.5 -22.5 577.9 -572.9 Present -PZ-155B 592.61 595.52 23.5 569.1 NA 17.5 -22.5 575.1 -570.1 Present -PZ-156A 593.90 596.48 NA NA NA 4.4 -9.4 589.5 -584.5 Present -PZ-156B 594.05 596.30 23.5 570.6 NA 17.5 -22.5 576.6 -571.6 Present -PZ-157B 588.33 591.18 18.5 569.8 NA 13.0 -18.0 575.3 -570.3 Present -PZ-158B 587.26 589.70 18.5 568.8 NA 13.0 -18.0 574.3 -569.3 Present -PZ-159B 592.09 594.23 13.5 578.6 NA 8.0 -13.0 584.1 -579.1 Present -PZ-160B 593.80 595.90 18.5 575.3 NA 13.0 -18.0 580.8 -575.8 Present -PZ-161B 592.09 594.71 23.5 568.6 NA 16.5 -21.5 575.6 -570.6 Present -PZ-162C 594.58 597.03 5.5 589.1 5.5 -20.0 14.6 -19.6 580.0 -575.0 Present NOTES: 1. Bold borings represent those in the Phase 4 Cell area 2. Measurements are in feet; elevations are relative to mean sea level 3. TOC = Top Of Casing 4. NA = Not Applicable Tab 2 - Borings UPRLF-DHR Cells 7-10 Prepared By: MSP/RLB Checked By: TJD/MSP TABLE 3 GROUNDWATER ELEVATION MEASUREMENTS & DEPTH TO GROUNDWATER Upper Piedmont Regional MSW Landfill - Phase 4 DHR Person County, North Carolina BLE Project Number J21-1003-81 GROUNDWATER ELEVATION MEASUREMENTS Maximum Minimum Difference Maximum Minimum Difference GROUND TOC 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 WELL ELEV.ELEV.TOB 24-Hr 9/7/06 10/24/06 11/29/06 12/20/06 1/16/07 2/21/07 3/21/07 4/24/07 5/11/07 6/12/07 7/26/07 8/15/07 10/5/07 1/10/08 7/21/08 1/29/09 7/30/09 1/14/10 7/15/10 1/20/11 7/14/11 1/30/12 7/25/12 2/4/13 7/8/13 1/21/14 7/21/14 1/29/15 7/27/15 1/26/16 7/26/16 2/1/17 7/25/17 1/31/18 7/25/18 1/25/19 7/23/19 1/28/20 7/28/20 2/10/21 3/25/21 4/14/21 5/20/21 6/24/21 7/27/21 8/17/21 9/14/21 10/27/21 11/15/21 12/20/21 1/24/22 2/15/22 Elev.Elev.Feet Elev.Elev.Feet GW-1 721.35 724.15 Dry 704.53 NM Dry Dry 694.95 Dry 703.50 704.36 705.99 704.25 699.54 NM Dry Dry 691.57 Dry Dry 698.11 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM -705.99 691.57 14.42 GW-1R 721.74 724.71 Dry 679.78 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 689.83 690.40 679.93 688.89 686.27 684.65 683.04 695.61 691.51 692.89 697.36 694.16 697.31 697.51 695.51 695.68 679.00 691.68 701.12 692.37 687.32 693.27 701.53 701.51 700.72 695.12 692.98 691.60 689.82 687.31 684.17 682.65 679.68 679.60 681.08 701.53 679.60 21.93 701.53 679.00 22.53 GW-2 598.00 600.39 560.30 575.88 NM 576.26 577.28 576.88 577.99 578.11 577.82 578.16 577.49 576.74 NM 575.14 NM 574.04 575.27 577.25 576.48 578.32 577.66 577.34 578.01 577.85 576.94 578.20 571.79 579.49 578.93 578.63 579.28 579.79 580.19 579.37 579.04 577.53 579.26 580.60 578.58 578.64 578.34 580.45 579.83 580.08 578.24 578.48 578.69 577.84 576.72 575.96 575.36 574.69 576.71 576.34 580.45 574.69 5.76 580.60 571.79 8.81 GW-3 560.12 562.55 532.12 552.97 NM 557.66 558.69 558.04 559.06 558.83 558.80 558.61 557.38 NM NM NM NM 556.85 555.81 558.60 556.65 558.56 556.21 557.54 556.58 557.82 558.41 558.68 558.10 557.95 556.96 558.72 556.77 558.77 557.92 558.55 556.65 557.66 557.24 559.67 556.43 558.53 556.39 559.85 559.01 559.14 557.15 557.27 557.54 556.68 555.63 555.39 555.21 554.83 557.63 557.24 559.85 554.83 5.02 559.85 554.83 5.02 GW-4 558.12 560.97 528.12 553.96 NM 557.36 558.10 557.52 558.33 558.16 557.96 557.79 556.87 NM NM NM NM 556.33 555.25 557.90 555.93 557.55 555.44 556.82 555.73 556.87 554.47 557.04 557.02 557.42 556.17 557.93 556.71 558.22 557.57 557.99 556.47 557.31 558.97 A A A A A A A A A A A A A A A A A A A -558.97 554.47 4.50 GW-4R 558.83 561.61 531.83 557.68 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 559.60 557.22 559.02 556.87 559.73 559.47 559.30 556.71 557.75 557.71 557.41 556.41 556.24 556.13 556.00 558.22 557.68 559.73 556.00 3.73 559.73 556.00 3.73 GW-5 559.40 562.13 556.50 557.13 NM 559.18 559.60 559.15 559.64 559.57 559.35 558.96 557.87 NM NM NM NM 558.03 556.93 559.36 557.48 559.28 556.77 558.19 557.23 557.65 556.23 558.17 558.81 558.96 557.83 559.50 558.00 559.93 558.73 559.23 557.53 559.23 559.05 559.92 557.55 559.18 557.32 559.98 559.87 559.23 557.72 558.07 558.63 557.81 556.92 556.93 556.51 556.72 559.02 558.19 559.98 556.51 3.47 559.98 556.23 3.75 GW-6 626.70 629.29 NS 608.28 NM 618.45 618.10 619.61 621.58 622.28 622.31 623.09 621.96 620.15 NM 616.89 NM 616.04 617.30 621.55 620.08 621.13 619.97 619.75 618.98 620.14 616.79 620.53 620.68 617.39 619.20 619.84 618.14 620.44 620.79 620.94 620.87 613.93 618.74 622.69 619.53 618.24 619.40 621.95 622.74 622.95 620.84 619.79 619.26 618.38 617.35 616.08 615.30 613.87 614.28 615.64 622.95 613.87 9.08 623.09 613.87 9.22 GW-7 581.51 584.06 Dry 570.71 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 572.05 576.17 572.01 575.75 574.46 577.31 575.11 576.81 576.76 577.15 576.16 576.42 576.21 578.60 576.32 578.04 576.67 578.86 579.00 578.91 577.93 577.98 578.21 577.52 576.45 575.92 575.52 574.84 577.43 576.98 579.00 574.84 4.16 579.00 572.01 6.99 GW-8 634.07 636.91 Dry 591.87 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 593.72 597.06 597.46 597.70 598.46 599.16 598.06 598.56 598.21 597.16 597.31 595.87 598.07 598.47 595.80 597.11 597.36 599.07 599.53 597.47 596.95 596.21 596.05 595.16 594.48 594.20 594.00 593.55 594.80 594.66 599.53 593.55 5.98 599.53 593.55 5.98 GW-9 609.33 612.26 586.03 598.10 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NM 599.71 595.35 594.79 595.61 596.84 594.96 595.64 598.26 597.93 597.11 598.83 596.81 599.16 598.66 599.43 598.21 599.12 598.86 601.49 598.65 600.81 598.77 601.64 600.79 600.11 NM 598.10 597.91 596.55 597.22 596.79 596.56 596.20 597.72 597.26 601.64 596.20 5.44 601.64 594.79 6.85 GW-10 616.51 619.14 590.81 602.56 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NM NM NM 601.86 601.56 602.24 601.42 602.85 602.82 604.16 606.37 604.04 602.49 604.34 604.14 604.54 603.94 604.94 606.90 606.88 603.66 605.15 603.36 606.90 605.32 603.65 603.68 603.44 603.69 602.93 602.39 602.39 602.14 601.86 604.54 603.94 606.90 601.86 5.04 606.90 601.42 5.48 GW-11 613.13 616.35 NM NM NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP -NP NP - GW-12 606.33 609.34 NM NM NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP -NP NP - PZ-1c 645.35 647.11 NS 633.25 NM 636.91 637.22 636.21 637.03 637.02 637.23 636.52 634.52 630.14 627.59 626.82 625.06 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -637.23 625.06 12.17 PZ-2ab 612.64 615.67 607.24 610.13 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP -NP NP - PZ-6ab 671.01 674.04 Dry 657.89 A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -A A - PZ-6c 671.13 672.58 NS 659.41 A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -A A - PZ-7c 634.47 637.04 NS 627.74 NM 622.81 623.64 624.06 624.63 624.96 625.13 625.54 625.44 625.24 NM 622.36 621.31 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP -625.54 621.31 4.23 PZ-9c 720.60 722.30 NS 714.22 NM Dry 712.04 712.57 713.83 713.12 713.60 714.48 710.90 705.90 Dry Dry Dry NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP -714.48 705.90 8.58 PZ-11a 622.06 623.90 620.32 621.73 NM Dry 620.19 620.62 621.03 621.26 621.48 621.49 620.88 NM NM NM Dry NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM 621.99 621.94 622.10 621.65 620.33 619.90 Dry Dry Dry Dry Dry 621.98 621.88 622.10 619.90 2.20 622.10 619.90 2.20 PZ-14c 625.50 626.88 NS 616.40 NM NM NM NM NM NM NM 619.03 618.18 615.95 NM 612.18 610.64 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM -619.03 610.64 8.39 PZ-20ab 607.93 610.97 592.33 597.81 NM 596.51 597.78 597.54 599.31 599.68 600.02 601.05 600.12 598.50 595.23 594.42 593.21 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM 599.37 600.48 600.99 NM 598.83 597.96 596.75 595.17 594.41 594.10 593.79 594.97 595.11 600.99 593.79 7.20 601.05 593.21 7.84 PZ-21ab 573.73 576.26 564.33 572.83 NM NM NM NM NM NM NM 571.88 570.21 568.66 NM 566.11 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM 572.69 572.55 572.46 569.85 568.99 568.69 570.78 566.00 565.87 565.70 565.77 568.41 568.81 572.69 565.70 6.99 572.69 565.70 6.99 PZ-22c 603.21 606.32 NS 593.03 NM 584.53 587.19 587.60 590.04 591.07 591.64 592.83 591.08 590.92 585.08 583.45 580.62 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM 588.17 589.79 590.14 588.17 586.09 589.98 583.44 581.57 579.92 578.79 577.93 578.21 578.65 590.14 577.93 12.21 592.83 577.93 14.90 PZ-24ab 601.04 604.01 Dry 572.43 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM -NM NM - PZ-27ab 584.03 587.00 Dry 580.14 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM -NM NM - PZ-28 645.28 648.59 Dry Dry NM NM NM NM NM NM NM NM Dry NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM -NM NM - PZ-30ab 592.78 595.61 Dry 576.19 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM -NM NM - PZ-34ab 631.11 634.07 Dry 613.20 NM 612.54 612.19 612.32 612.28 612.19 612.05 612.16 612.05 612.07 NM 611.63 611.62 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -612.54 611.62 0.92 PZ-37ab 598.81 601.92 597.13 597.27 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM -NM NM - PZ-40ab 585.60 588.25 583.38 583.48 NM NM 583.93 583.99 584.95 584.79 584.56 582.86 Dry NM NM NM Dry NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -584.95 582.86 2.09 PZ-42a 553.84 555.68 550.88 553.08 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM 553.28 551.83 551.86 552.04 Dry Dry 551.47 Dry 551.94 552.95 552.94 553.28 551.47 1.81 553.28 551.47 1.81 PZ-63c 642.09 643.19 NS 635.73 A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -A A - PZ-69ab 595.60 599.06 Dry 595.55 NM NM NM NM NM NM NM NM 593.66 591.65 NM 588.21 586.85 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM 595.74 595.75 595.61 593.68 593.94 594.80 593.88 592.58 593.36 593.38 593.36 595.81 595.66 595.81 592.58 3.23 595.81 586.85 8.96 PZ-72ab 599.90 601.93 Dry 588.43 NM NM NM NM NM NM NM NM 591.23 589.73 NM 586.13 585.08 NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM NM 590.89 592.51 592.59 591.04 589.63 588.70 587.68 Dry Dry Dry Dry Dry Dry 592.59 587.68 4.91 592.59 585.08 7.51 PZ-101ab 610.95 614.30 Dry Dry Dry Dry 602.36 600.71 603.08 601.60 601.38 601.91 601.00 Dry NM Dry Dry NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -603.08 600.71 2.37 PZ-102b 624.60 627.79 NS 607.10 606.00 606.17 617.07 612.18 618.40 615.55 616.28 615.46 612.61 610.19 606.36 605.02 602.29 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -618.40 602.29 16.11 PZ-105c 637.01 640.04 NS 616.26 616.29 616.06 618.30 616.75 610.14 617.35 616.63 616.71 616.60 616.44 NM 616.07 616.07 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -618.30 610.14 8.16 PZ-107ab 631.40 634.54 620.30 Dry Dry Dry 622.09 620.38 621.67 621.20 621.29 621.15 619.76 620.04 NM Dry Dry NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -622.09 619.76 2.33 PZ-109c 658.63 661.93 NS 636.98 637.28 637.16 641.92 636.77 649.76 639.41 646.11 646.90 637.56 637.71 NM 636.48 635.66 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -649.76 635.66 14.10 PZ-110ab 621.58 624.75 Dry Dry Dry Dry 606.82 606.63 607.15 607.17 608.84 608.03 606.56 606.45 NM Dry Dry NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -608.84 606.45 2.39 PZ-113ab 669.03 672.18 Dry 653.83 653.91 655.71 659.09 658.40 660.72 A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -660.72 653.91 6.81 PZ-114b 658.49 660.79 624.41 624.94 625.34 625.51 630.75 628.98 632.99 631.92 631.85 631.91 630.58 629.66 627.93 627.27 625.69 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -632.99 625.34 7.65 PZ-116c 602.76 606.18 NS 599.01 599.03 599.03 599.40 600.49 601.61 601.97 602.14 602.22 601.71 601.46 NM 600.20 599.12 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -602.22 599.03 3.19 PZ-118c 589.84 593.34 NS 582.49 583.59 584.16 585.17 584.26 585.15 584.86 585.15 584.74 583.99 583.49 NM 582.24 581.02 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -585.17 581.02 4.15 PZ-119ab 584.23 586.50 Dry 577.23 577.30 578.35 579.36 578.73 579.99 579.56 579.40 579.55 578.60 577.75 576.54 576.00 574.73 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -579.99 574.73 5.26 PZ-120b 598.05 601.03 Dry 586.65 586.73 587.31 590.09 588.54 591.01 589.58 589.54 590.09 588.34 587.88 NM 586.21 585.03 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -591.01 585.03 5.98 PZ-121b 612.87 616.32 Dry 605.87 605.92 606.59 607.94 606.61 607.81 607.37 607.47 607.28 606.34 605.52 NM 603.57 602.44 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -607.94 602.44 5.50 PZ-122c 658.07 661.03 NS 636.07 Dry 634.40 NM 636.56 643.62 638.10 642.75 642.79 641.38 641.36 NM 639.08 638.21 NM NM NM A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -643.62 634.40 9.22 PZ-124c 676.79 679.54 NS 650.44 650.49 650.03 Dry Dry Dry A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A -650.49 650.03 0.46 PZ-126B 629.78 632.25 Dry 620.78 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 622.29 625.73 622.53 620.69 619.35 618.20 616.45 614.49 613.62 612.44 612.98 613.76 625.73 612.44 13.29 625.73 612.44 13.29 PZ-128B 627.01 629.46 Dry 619.01 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 621.49 621.88 619.01 617.20 614.96 Dry Dry Dry Dry Dry Dry Dry 621.88 614.96 6.92 621.88 614.96 6.92 PZ-129B 632.42 635.11 Dry 619.42 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 627.63 627.59 624.46 624.46 624.26 621.82 620.13 615.04 Dry Dry 616.98 623.02 627.63 615.04 12.59 627.63 615.04 12.59 PZ-131AB 616.06 618.60 Dry Dry NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 603.21 604.35 604.19 603.52 602.81 602.69 602.21 600.59 600.08 599.37 599.56 599.41 604.35 599.37 4.98 604.35 599.37 4.98 PZ-132B 620.26 622.66 Dry 606.26 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 612.69 612.86 610.86 609.84 609.36 608.39 607.05 606.44 606.11 605.75 607.43 607.41 612.86 605.75 7.11 612.86 605.75 7.11 PZ-133C 627.01 629.31 Dry 625.51 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 625.08 620.07 616.86 614.63 613.28 613.75 612.34 609.55 608.78 608.01 Dry Dry 625.08 608.01 17.07 625.08 608.01 17.07 PZ-133AB 627.64 630.34 Dry Dry NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 627.80 623.20 620.84 619.05 617.29 Dry Dry Dry Dry Dry Dry Dry 627.80 617.29 10.51 627.80 617.29 10.51 PZ-134AB 617.34 619.94 Dry 597.43 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 599.60 601.08 602.86 603.12 602.69 602.33 601.52 600.30 599.83 599.09 598.60 598.40 603.12 598.40 4.72 603.12 598.40 4.72 PZ-135B 611.85 614.25 Dry 596.55 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 604.43 604.76 603.69 602.84 602.25 601.56 600.42 599.61 599.15 598.50 598.62 598.44 604.76 598.44 6.32 604.76 598.44 6.32 PZ-136B 600.32 602.67 Dry 589.32 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 594.93 596.11 593.63 592.45 591.37 590.86 590.04 Dry Dry Dry Dry Dry 596.11 590.04 6.07 596.11 590.04 6.07 PZ-137B 612.33 614.66 Dry 609.33 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 601.89 602.50 601.42 600.28 599.35 598.53 597.21 596.08 Dry Dry Dry Dry 602.50 596.08 6.42 602.50 596.08 6.42 PZ-138B 608.67 611.32 Dry 600.67 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 599.48 599.62 598.83 598.10 597.42 596.51 595.05 594.15 593.71 593.20 593.50 593.59 599.62 593.20 6.42 599.62 593.20 6.42 PZ-139C 605.75 608.30 Dry Dry NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 605.44 603.27 601.46 602.76 602.68 601.99 600.70 601.71 594.25 594.12 602.15 601.15 605.44 594.12 11.32 605.44 594.12 11.32 PZ-140B 604.28 606.60 574.72 594.97 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 595.01 595.21 590.50 588.67 587.38 585.92 582.98 580.00 578.75 576.99 579.43 579.09 595.21 576.99 18.22 595.21 576.99 18.22 PZ-141B 592.51 594.14 Dry 580.51 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 590.61 590.45 587.56 586.23 585.05 583.73 581.40 579.08 578.17 576.29 577.38 578.77 590.61 576.29 14.32 590.61 576.29 14.32 PZ-142B 588.57 590.92 Dry 583.03 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 584.31 584.07 581.52 581.16 580.70 579.71 577.87 576.31 575.52 574.89 577.62 578.08 584.31 574.89 9.42 584.31 574.89 9.42 PZ-143B 583.40 585.75 Dry 580.66 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 580.88 581.05 578.36 578.29 578.15 576.92 574.82 573.26 572.64 571.28 575.69 576.52 581.05 571.28 9.77 581.05 571.28 9.77 PZ-144B 611.92 614.45 Dry 609.92 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 607.15 607.67 604.52 602.04 600.78 Dry Dry Dry Dry Dry Dry Dry 607.67 600.78 6.89 607.67 600.78 6.89 PZ-145B 604.50 606.62 Dry 596.50 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 590.65 591.54 590.86 589.51 588.44 Dry Dry Dry Dry Dry Dry Dry 591.54 588.44 3.10 591.54 588.44 3.10 PZ-146AB 599.35 601.84 Dry 597.35 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 592.25 594.72 594.02 592.47 592.24 Dry Dry Dry Dry Dry 594.67 593.85 594.72 592.24 2.48 594.72 592.24 2.48 PZ-147B 614.25 616.69 586.35 594.83 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 602.57 600.53 594.12 590.89 588.27 Dry Dry Dry Dry Dry Dry Dry 602.57 588.27 14.30 602.57 588.27 14.30 PZ-148B 606.96 609.06 582.77 587.96 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 594.91 594.57 590.82 588.81 587.15 585.55 582.85 580.06 579.05 577.39 578.41 579.74 594.91 577.39 17.52 594.91 577.39 17.52 PZ-149B 596.17 598.89 Dry 585.04 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 591.27 591.24 588.37 587.11 585.96 584.63 581.73 Dry Dry Dry Dry Dry 591.27 581.73 9.54 591.27 581.73 9.54 PZ-150B 593.44 595.34 Dry 586.10 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 586.14 585.86 582.94 582.70 582.53 581.10 577.61 Dry Dry Dry 579.32 580.79 586.14 577.61 8.53 586.14 577.61 8.53 PZ-151B 593.62 596.14 Dry 591.62 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 590.43 590.65 588.44 587.12 586.34 585.09 583.39 582.84 582.60 582.75 584.18 584.52 590.65 582.60 8.05 590.65 582.60 8.05 PZ-152B 597.11 599.61 Dry Dry NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP Dry 595.22 593.07 592.17 591.57 591.24 Dry Dry Dry Dry 594.35 595.33 595.33 591.24 4.09 595.33 591.24 4.09 PZ-153B 599.36 602.12 Dry 587.36 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 592.44 593.20 588.74 586.21 584.02 582.03 578.87 Dry 573.90 572.21 573.24 574.74 593.20 572.21 20.99 593.20 572.21 20.99 PZ-154B 595.40 597.40 Dry 582.86 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 590.14 590.61 588.13 586.57 585.31 583.89 581.79 579.23 578.02 576.24 577.47 578.27 590.61 576.24 14.37 590.61 576.24 14.37 PZ-155B 592.61 595.52 Dry 580.78 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 586.72 588.25 582.66 583.35 584.52 582.22 577.92 575.71 574.88 Dry 584.68 583.61 588.25 574.88 13.37 588.25 574.88 13.37 PZ-156A 593.90 596.48 Dry 590.91 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 591.14 591.10 586.57 587.44 588.38 586.29 Dry Dry Dry Dry 589.70 589.07 591.14 586.29 4.85 591.14 586.29 4.85 PZ-156B 594.05 596.30 581.86 580.31 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 590.08 591.12 585.62 587.43 588.21 584.75 579.14 576.80 575.49 Dry 589.55 588.95 591.12 575.49 15.63 591.12 575.49 15.63 PZ-157B 588.33 591.18 Dry 583.33 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 587.69 587.81 584.15 582.71 581.88 580.64 578.94 578.73 578.67 579.25 581.16 581.86 587.81 578.67 9.14 587.81 578.67 9.14 PZ-158B 587.26 589.70 Dry 582.26 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 578.38 581.60 579.30 577.74 577.20 575.76 574.00 573.78 573.39 573.42 576.13 576.90 581.60 573.39 8.21 581.60 573.39 8.21 PZ-159B 592.09 594.23 Dry 576.09 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP Dry 589.49 583.14 580.11 578.95 Dry 578.88 Dry Dry Dry Dry Dry 589.49 578.88 10.61 589.49 578.88 10.61 PZ-160B 593.80 595.90 Dry 581.80 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 580.42 588.59 582.22 582.27 582.52 582.07 581.59 580.52 580.12 578.91 582.50 581.98 588.59 578.91 9.68 588.59 578.91 9.68 PZ-161B 592.09 594.71 Dry 580.57 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 581.13 582.06 578.67 579.07 579.81 577.95 576.11 575.43 574.68 572.46 578.98 578.38 582.06 572.46 9.60 582.06 572.46 9.60 PZ-162C 594.58 597.03 Dry 585.73 NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP NP 585.76 583.34 578.03 578.45 579.59 577.47 Dry Dry Dry Dry 580.36 577.97 585.76 577.47 8.29 585.76 577.47 8.29 NOTES: 1. TOB = Time Of Boring 5. A = Abandoned 2. TOC = Top Of Casing 6. NS = water level Not Stable; the water level was at the ground surface due to rock coring activities. 3. NP = Not Present at time of measurement 7. Bold elevations represent highest observed elevations between 2/10/21 to 2/15/22. 4. NM = Not Measured 8. Measurements are in feet; elevations are relative to mean sea level. 2021-2022 Yearly Seasonal High Water Table Elevations Long Term Seasonal High Water Table Elevations 2006 to Present Tab 3 - Water Levels \\blegvlfs1\SolidWasteProjects\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\97 Spreadsheets\UPRLF-DHR Cells 7-10 Prepared By: MSP/RLB Checked By: TAO/TJD TABLE 4 SUMMARY OF IN-SITU HYDRAULIC TESTING - SLUG TEST RESULTS Upper Piedmont Regional MSW Landfill - Phase 4 DHR Person County, North Carolina BLE Project Number J21-1003-81 Well/Method Data Type Aquifer Unit K(ft/min)K(cm/sec)K(ft/day) Piezometer GW-6 Bouwer-Rice Falling Head Bedrock 8.4E-07 4.3E-07 1.2E-03 PZ-20ab Bouwer-Rice Falling Head Partially Weathered Rock 1.3E-05 6.7E-06 1.9E-02 PZ-22c Bouwer-Rice Falling Head Bedrock 4.4E-06 2.2E-06 6.3E-03 PZ-132B Bouwer-Rice Falling Head Partially Weathered Rock 6.5E-05 3.3E-05 9.4E-02 PZ-139C Bouwer-Rice Falling Head Bedrock 5.5E-07 2.8E-07 7.9E-04 PZ-142B Bouwer-Rice Falling Head Partially Weathered Rock 2.2E-05 1.1E-05 3.2E-02 PZ-148B Bouwer-Rice Falling Head Deep Residuum 7.6E-05 3.9E-05 1.1E-01 PZ-153B Bouwer-Rice Falling Head Deep Residuum 1.3E-05 6.7E-06 1.9E-02 PZ-158B Bouwer-Rice Falling Head Partially Weathered Rock 2.5E-06 1.3E-06 3.6E-03 Maximum Hydraulic Conductivity 7.6E-05 3.9E-05 0.11 Deep Residuum Only Geometric Mean Hydraulic Conductivity 3.2E-05 1.6E-05 0.046 Minimum Hydraulic Conductivity 1.3E-05 6.7E-06 0.019 Maximum Hydraulic Conductivity 6.5E-05 3.3E-05 0.09 PWR Only Geometric Mean Hydraulic Conductivity 1.5E-05 7.5E-06 0.021 Minimum Hydraulic Conductivity 2.5E-06 1.3E-06 0.004 Maximum Hydraulic Conductivity 4.4E-06 2.2E-06 0.01 Bedrock Only Geometric Mean Hydraulic Conductivity 1.3E-06 6.4E-07 0.002 Minimum Hydraulic Conductivity 5.5E-07 2.8E-07 0.001 Maximum Hydraulic Conductivity 7.6E-05 3.9E-05 0.11 All Units Geometric Mean Hydraulic Conductivity 7.7E-06 3.9E-06 0.011 Minimum Hydraulic Conductivity 5.5E-07 2.8E-07 0.001 NOTES: 1. K = Hydraulic Conductivity 2. The data was reduced and the hydraulic conductivities calculated using SuperSlug (version 3.0) and AQTESOLV (version 1.1). Tab 4 - Slug Tests UPRLF-DHR Cells 7-10 Prepared By: MSP/RLB Checked By: MSP TABLE 5 SUMMARY OF LABORATORY RESULTS - SPLIT SPOON AND SHELBY TUBE SAMPLES Upper Piedmont Regional MSW Landfill - Phase 4 DHR Person County, North Carolina BLE Project Number J21-1003-81 Triaxial Shear Consolidation Split-Spoon Shelby Tube Soil Unit Hydraulic Cond. Nat. Moisture Cohesion (ksf)F (degree)Precon. Press.Void Ratio Effective Total Atterberg Limits Grain Size (% by wt) Boring Depth (ft) Depth (ft) (cm/sec) Content (%) Total Effective Total Effective Pc (ksf) (eo) Porosity (%) Porosity (%) LL PL PI Gravel Sand Silt Clay USCS B-19 3.5 - 5.0 - Deep Residuum - 15.0% - - - - - - - - - - - - 37.3% 42.7% 20.0% SM* B-20 1.0 - 2.5 - Upper Residuum - 20.0% - - - - - - - - - 33 18 14 1.3% 25.3% 73.4% CL B-20 - 3.0 - 3.5 Upper Residuum 1.4E-05 24.9% - - - - - - - 1.0%53.0%57 24 33 4.2% 8.2% 25.5% 62.1% CH B-68 1.0 - 2.5 - Upper Residuum - 11.0% - - - - - - - --39 15 24 - - 35.1% SC B-72 1.0 - 2.5 - Upper Residuum - 31.4% - - - - - - - --72 18 54 - - 92.0% CH B-72 3.5 - 5.0 - Deep Residuum - - - - - - - - - 11.0% 56.0% 36 26 10 0.0% 25.7% 60.0% 14.3% ML B-72 13.5 - 15.0 - Partially Weathered Rock - 10.4% - - - - - - - 20.0%49.0%- - - 0.0% 62.1% 28.6% 9.3% SM* B-125 3.5 - 5.0 - Partially Weathered Rock - 11.5% - - - - - - - 25.0%34.1%24 17 7 19.2% 60.5% 11.6% 8.7% SC-SM B-138 8.5 - 10.0 - Partially Weathered Rock - 8.4% - - - - - - - 18.7%41.2%30 17 13 18.1% 50.6% 21.6% 9.7% SC B-140 - 8.0 - 10.0 Upper Residuum 4.4E-07 18.4% - - - - - - - 21.0%52.6%27 21 6 0.0% 26.0% 52.8% 21.2% CL-ML B-140 - 23.0 - 24.5 Deep Residuum 2.1E-05 19.6% - - - - - - - 19.2%48.0%29 25 4 0.0% 23.8% 62.0% 14.2% ML B-147 1.0 - 2.5 - Upper Residuum - 25.5% - - - - - - - 22.5%56.3%56 28 28 0.8% 18.6% 26.5% 54.1% CH B-147 13.5 - 15.0 - Deep Residuum - 17.2% - - - - - - - 19.9%49.7%38 28 10 0.0% 36.8% 38.3% 24.9% ML B-147 28.5 - 30.0 - Partially Weathered Rock - 9.3% - - - - - - - 18.4%40.5%33 24 9 12.3% 45.9% 27.1% 14.7% SC B-148 - 3.0 - 5.0 Upper Residuum 1.7E-06 36.2% - - - - - - - 21.7%54.4%44 29 15 0.0% 5.8% 51.9% 42.3% ML B-148 - 13.0 - 15.0 Deep Residuum 5.1E-06 39.5% - - - - 7.18 0.41 1.147 21.5%53.8%46 32 14 0.0% 13.2% 50.2% 36.6% ML B-148 - 23.0 - 25.0 Deep Residuum - 47.9% 0.77 0.33 12.2 27.31 - - - 21.7%54.2%54 32 22 0.0% 15.3% 47.5% 37.2% MH B-151 8.5 - 10.0 - Deep Residuum - 9.3% - - - - - - - 24.3%39.8%32 19 13 8.6% 53.4% 21.0% 17.0% SC B-155 3.5 - 5.0 - Upper Residuum - 31.5% - - - - - - - 21.2%53.1%39 29 10 0.0% 12.8% 60.6% 26.6% ML B-156 13.5 - 15.0 - Partially Weathered Rock - 11.9% - - - - - - - 27.6%36.4%32 19 13 30.4% 34.2% 24.2% 11.2% SC B-157 - 3.0 - 5.0 Upper Residuum 2.7E-07 11.1% - - - - - - - 20.6%45.3%27 22 5 0.0% 45.8% 47.3% 6.9% CL-ML B-160 - 3.0 - 4.5 Upper Residuum 9.1E-08 23.1% - - - - - - - 21.9%54.7%47 27 20 4.9% 13.9% 34.8% 46.4% CL NOTES: 1. Moisture Content % = (Weight of water/Weight of soil) * 100 2. The effective porosity and total porosity was calculated using methodology presented in the EPAs "Composite Model for Leachate Migration with Transformation Products" dated April 2003. 3. USCS = Unified Soil Classification System. Refer to Appendix C for a description of the abbreviations. 4. "*" indicates that the USCS is an estimation based on field classification and grain size test. Cc Tab 5 - Soil Lab (jar-UD) UPRLF-DHR Cells 7-10 Prepared By: RLB Checked By: ZJD TABLE 6 SUMMARY OF LABORATORY RESULTS - REMOLDED BAG SAMPLES Upper Piedmont Regional MSW Landfill - Phase 4 DHR Person County, North Carolina BLE Project Number J21-1003-81 Standard Proctor Remolded Permeability Conditions Triaxial Shear Bag Sample Soil Natual Opt. Moisture Max. Dry Pressure Moisture Content Dry Density Hydraulic Cohesion (ksf)F (degree)Atterberg Limits Grain Size (% by wt) Boring Depth (ft)Unit Moisure Content (%)Density (pcf)Gradient (PSI)%% Wet of Opt.pcf % of MDD Cond. (cm/sec)Total Effective Total Effective LL PL PI Gravel Sand Silt Clay USCS PZ-140 8.5 - 15.0 Upper Residual - 18.0% 101.9 - - - - - - - - - - 53 25 28 0.0% 16.6% 47.3% 36.1% CH PZ-159 2.0 - 8.0 Deep Residual - 11.9% 121.4 - - - - - - 0.257 0.091 17.24 30.3 30 19 11 17.5% 42.2% 23.5% 16.8% SC PZ-160 2.0 - 7.0 Deep Residual - 19.5% 103.4 - - - - - - - - - - 45 26 19 0.0% 8.8% 46.5% 44.7% CL NOTES: 1. Moisture Content % = (Weight of water/Weight of soil) * 100 2. USCS = Unified Soil Classification System. Refer to Appendix B for a description of the abbreviations. 3. Grain size test results for B-6 are from undisturbed samples collected at similar depths (see Table 5). Tab 6 - Soil Lab (remolded) UPRLF-DHR Cells 7-10 Prepared By: RLB Checked By: ZJD TABLE 7 INTERSTITIAL GROUNDWATER FLOW VELOCITY CALCULATIONS Upper Piedmont Regional MSW Landfill - Phase 4 DHR Person County, North Carolina BLE Project Number J21-1003-81 Geometric Mean Values Part of Hydraulic Hydraulic Effective Groundwater Geologic Unit Water Table Aquifer Conductivity (K)Gradient (i)Porosity (n)Velocity (V) in Phase 4 (feet per day)(unitless)(unitless)(feet per day) Upper Residuum Soil Unit No 0.040 0.050 0.215 0.009 Deep Residuum Soil Unit Yes 0.046 0.050 0.212 0.011 Partially Weathered Rock Yes 0.021 0.050 0.221 0.005 Bedrock Yes 0.002 0.050 0.071 0.001 Saturated Units Deep Residuum, PWR, & Bedrock 0.011 0.050 0.163 0.003 Notes: 1. The geometric mean hydraulic conductivity values in the Deep Residuum, Partially Weathered Rock, and Bedrock are from slug tests conducted in the Phase 4 Cell area (Table 4). 2. The geometric mean hydraulic conductivity values in the Upper Residuum are from soil laboratory testing in the Phase 4 area (Table 5). 3. Effective porosity values values in the Upper Residuum, Deep Residuum, and Partially Weathered Rock are from soil laboratory testing in the Phase 4 area (Table 5). 4. Effective porosity values in the Bedrock are from published values (5 to 10 percent) (Kruseman & deRidder, 1989). 5. Hydraulic gradient information is from the October 27, 2021 Water Table Contour Map (Figure 8). 6. The high velocity hydraulic gradient (0.088 ft/ft) is in the north western portion of Phase 4. 7. The low velocity hydraulic gradient (0.028 ft/ft) is in the south western portion of Phase 4. 8. "Saturated Units" are the units making up the uppermost water table aquifer (Deep Residuum, Partially Weathered Rock, and Bedrock). Tab 7 - Flow V UPRLF-DHR Cells 7-10 Prepared by: RLB Checked by: TJD TABLE 8 SUMMARY OF HYDROGEOLOGIC CHARACTERISTICS OF GEOLOGIC UNITS Upper Piedmont Regional MSW Landfill - Phase 4 DHR Person County, North Carolina BLE Project Number J21-1003-81 Geologic Unit USCS Grain Size Total Porosity Effective Porosity Hydraulic Conductivity (cm/sec) gravel sand silt clay max min geomean max min geomean max min geomean Upper Residuum Soil CL, CH, ML, MH 1.4%19.6%42.8%37.1%56.3%45.3%52.6%22.5%1.0%21.5%--- Deep Residuum Soil SM, ML, SC 6.6%30.1%46.5%24.0%56.0%39.8%48.8%24.3%11.0%21.2%3.9E-05 6.7E-06 1.6E-05 Partially Weathered Rock SM, ML, SC 16.0%50.7%22.6%10.7%49.0%34.1%37..9%27.6%18.4%22.1%3.3E-05 1.3E-06 7.5E-06 Bedrock Rhyolite, Rhyolite Porphyry ----10.0%5.0%7.1%10.0%5.0%7.1%2.2E-06 2.8E-07 6.4E-07 Andesite, Andesite Porphyry Notes: 1. Values are summarized from Table 4 (Summary of Slug Test Results) and Table 5 (Summary of Laboratory Results). 2. Grain size values are averages. 3. "geomean" is the geometric mean. 4. Values of porosity in Bedrock are from published values (Kruseman & deRidder, 1989). Tab 8 - Unit Soil Summay UPRLF-DHR Cells 7-10 Prepared By: RLB Checked By: TJD FIGURES 1 SITE 620 4 SITE 570570 560560580 580590590 600600610 610 620 620 630 640 630 640 650 650 660 660 670 670 680 680 590590 620 580 07/07/2023 570 560580590 600 6106206305905906201/18/241/18/24 620 07/07/2023 620 07/07/2023 57 0 56056058 0 580590600600 610 610 620 620 630 640 630 640 650 650 660 660 67 0 680 670 680 590570620 580 07/07/2023 57057 0 56056058 0 580590590 600600 610 610 620 620 630 640 630 640 650 650 660 660 670 670 680 680 590590 620 580 07/07/2023 07/07/2023 57057 0 56056058 0 580590590 600600 610 610 620 620 630 640 630 640 650 650 660 660 670 670 680 680 590590 620 580 07/07/2023 APPENDIX A Drilling and Sampling Procedures APPENDIX A Drilling and Sampling Procedures SOIL TEST BORINGS Soil test borings were advanced by mechanically twisting a continuous flight steel auger into the soil. Soil sampling and penetration testing were performed in general accordance with ASTM D 1586. At regular intervals, soil samples were obtained with a standard 1.4-inch ID, 2-inch OD, split-tube sampler. The sampler was first seated 6 inches to penetrate any loose cuttings, and then driven an additional 12 inches with blows of a 140-pound hammer falling 30 inches. The number of hammer blows required to drive the sampler the final 12 inches was recorded and designated the "penetration resistance." CORE DRILLING Core drilling procedures were required to determine the character and vertical continuity of refusal materials. Refusal to soil drilling equipment may result from hard cemented soil, soft weathered rock, coarse gravel or boulders, thin rock seams, or the upper surface of solid continuous rock. Prior to coring, a 4-inch diameter PVC pipe was seated in the refusal material and grouted into place with a cement-bentonite mixture. Refusal materials were then cored according to the ASTM D 2113 using a diamond-studded bit fastened to the end of a hollow, double-tube core barrel. The NQ and HQ sizes designate bits that obtain rock cores 1-7/8 and 2-1/2 inches in diameter. Upon completion of each drill run, the core inner barrel was brought to the surface, the core recovered was measured, and the core samples were removed and placed in boxes for storage. The core samples were returned to our laboratory where the refusal material was identified and the percent core recovery and rock quality designation (RQD) was determined by a geologist. The percent core recovery is the ratio of the core length obtained to the length cored, expressed as a percent. The RQD is obtained by summing only those pieces of recovered core which are 4 inches or longer and are at least moderately hard, and dividing by the total length cored. The percent core recovery and the RQD are related to soundness and continuity of the refusal material. Refusal-material descriptions, recoveries and the bit size are shown on the Test Boring Records (see Appendix B). APPENDIX B Soil and Rock Boring Records and Well Diagrams APPENDIX B Soil and Rock Boring Records and Well Diagrams TIMING AND DRILLING CONTRACTORS Piezometers and monitoring wells have been installed at the site since February 1995. The piezometers were installed as part of Site Hydrogeologic and Design Hydrogeologic investigations performed at the site in the past. The monitoring wells were installed as part of the water quality monitoring system for the constructed landfill cells. North Carolina-licensed drilling contractors installed the piezometers and wells. The contractors were selected based on their drilling and well installation capabilities, and anticipated subsurface conditions. The piezometers installed in soil were performed by Law Engineering, Inc., Superior Drilling, Inc., AE Drilling Inc., Metro Drilling, Inc., and Bridger Drilling, Inc. The piezometers and monitoring wells installed in bedrock were performed by Law Engineering, Inc., Superior Drilling, Inc., AE Drilling, Inc., Metro Drilling, Inc., and Bridger Drilling Inc. PIEZOMETER CONSTRUCTION AND NOMENCLATURE Piezometer identification numbers were designated with the letters “A,” “B,” or “C” depending on the location of the screened interval in the piezometer. Piezometers with a screened interval which brackets the water table and is above the depth of auger refusal, were designated with the letter “A.” Piezometers with a screened interval at the depth of auger refusal (top of bedrock surface) and below the water table were designated with the letter “B.” In cases where the water table was near the depth of auger refusal, the piezometer identification number was designated using “AB.” Bedrock piezometers were designated with the letter “C”. Piezometers that are dry do not have a letter designation. A typical schematic diagram of piezometer construction and nomenclature is shown below. SILTS and CLAYS Groundwater Table 24 Hours after Completion of Drilling Very Soft Soft Firm Stiff Very Stiff Hard Very Hard Silt KEY TO SOIL CLASSIFICATIONS Relative Density *ASTM D 1586 Groundwater Table at Time of Drilling Consistency Particle Size Identification Very Loose Loose Firm Very Firm Dense Very Dense CL-ML ML Poorly-graded Gravel Well-graded Gravel GP 0 to 2 3 to 4 5 to 8 9 to 15 16 to 30 31 to 50 over 50 Clayey Silt Silty Sand Partially Weathered Rock High Plasticity Clay GW SC Clayey Sand MH SW KEY TO DRILLING SYMBOLS SANDS Sand Low Plasticity Clay CL BLDRCBBL CH 0 to 4 5 to 10 11 to 20 21 to 30 31 to 50 over 50 Penetration Resistance* Blows per Foot Boulder: Greater than 300 mm Cobble: 75 to 300 mm Gravel: Coarse - 19 to 75 mm Fine - 4.75 to 19 mm Sand: Coarse - 2 to 4.75 mm Medium - 0.425 to 2 mm Fine - 0.075 to 0.425 mm Silt & Clay: Less than 0.075 mm Penetration Resistance* Blows per Foot KEY TO SOIL CLASSIFICATIONS AND CONSISTENCY DESCRIPTIONS BUNNELL-LAMMONS ENGINEERING, INC. GREENVILLE, SOUTH CAROLINA SM Silty Clay Undistrurbed Sample Split Spoon Sample Grab Sample TOPSOIL Topsoil MSW Limestone LIMESTONE 6-inches of TOPSOIL PARTIALLY WEATHERED ROCKwhich sampled as brown andyellowish-brown, moist, clayey,silty, fine to coarse SAND withgravel size rock fragments Soft to hard, very severely tomoderately weathered, gray andbrown, ANDESITE PORPHYRY;with massive bedding; and veryclose to closely spaced, moderateto steeply dipping, open,clay-filled joints.R-1 recovery = 83%, RQD = 17 Moderately hard to hard,moderately weathered, grayANDESITE PORPHYRY; withmassive bedding; and very closeto moderately closely spaced,moderate to steeply dipping,clay-filled joints.R-2 recovery = 68%, RQD = 28 Hard, moderate to slightly weathered, gray ANDESITE PORPHYRY; with massive bedding; and very close to closely spaced, moderate to steeply dipping, open joints. R-3 recovery = 92%, RQD = 0 Very hard, very slightlyweathered, gray ANDESITEPORPHYRY; with very thin,shallow dipping bedding; andclose to moderately close, steeplydipping, closed joints.R-4 recovery = 96%, RQD = 86 Auger refusal at 5.3 feet. 50/1.5" R-1 R-2 R-3 R-4 SURFACE COMPLETIONlocked 4" x 4" stand-up steel coverwith a 4' x 4' sloped concrete padat it's base Grout, 0 to 5.7 feet Bentonite seal, 5.7 to 9.7 feet Filter pack, sand 9.7 to 25.7 feet .010-inch slotted Schedule 40 PVCwell screen, 10.5 to 25.5 feet Pipe cap Total well depth, 25.7 feet PVC diameter, 2.0-inches Corehole diameter, 4.0-inches Ground surface elevation = 626.70' Top of PVC casing = 629.29' Northing = 936,193.39' Easting = 2,049,092.51' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 625 620 615 610 605 600 595 590 CAVING> GROUND WATER MONITORING WELL NO. GW-6Sheet 1 of 1 1-7-04 DEPTH TO - WATER> INITIAL: CLIENT: PROJECT NO.: END:Republic/HHNT Person County, North Carolina Terracon, B. Fletcher ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 550 ATV; HQ Rock Coring J03-1003-41 AFTER 24 HOURS:18.42 GROUND WATER MONITORING WELL NO. GW-6 START: 1-6-04 626.70ELEVATION: M. PreddyLOGGED BY: Upper Piedmont MSW Landfill GEOT_WELL 1003-41.GPJ 4/21/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Very dense, gray, wet, silty, clayey, fine to coarse SAND - (RESIDUUM) PARTIALLY WEATHERED ROCK sampled as very dense, gray, wet,silty, clayey, fine to coarse SAND with gravel Auger refusal at 6.0 feet below ground surface. No groundwaterencountered at time of drilling. 1237 2350/2" 50/0" SOIL DESCRIPTION SOILTYPE SAMPLESLOCATION: DRILLER: DRILLING METHOD: 625 620 615 610 605 600 595 590 CAVING> BORING NO. B-125Sheet 1 of 1 3-11-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:Dry BORING NO. B-125 START: 3-11-21 628.10ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_NOWELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT 50/2" Soft, light brown, moist, fine tocoarse sandy SILT - (FILL) Firm, red, moist, fine sandy SILTwith trace clay - (RESIDUUM) Very dense, gray, moist, silty, fineto coarse SAND with trace gravel PARTIALLY WEATHERED ROCKsampled as very dense, gray, dry,silty, fine to coarse SAND withtrace gravel PARTIALLY WEATHERED ROCKsampled as very dense, gray,moist, fine to medium sandy, clayey, aphanitic rhyolite GRAVEL PARTIALLY WEATHERED ROCKsampled as very dense, brown,dry, silty, fine to coarse SAND PARTIALLY WEATHERED ROCK sampled as very dense, lightbrown, dry, silty, fine to coarseSAND Auger refusal at 23.5 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 7.49 feet belowground surface. 213 334 102637 50/5" 50/1" 50/3" 50/1" Grout, 0 to 5.0 feet Bentonite seal, 5.0 to 15.0 feet Filter pack, sand 15.0 to 23.5 feet 2-inch diameter, 0.010-inch slotted Schedule 40 PVC well screen, 17.5to 22.5 feet Pipe cap 0.33 feetTotal well depth, 22.83 feet SURFACE COMPLETION2.47-foot PVC stick-up with a venthole.Top of PVC casing elev. = 632.25' Ground surface elev. = 629.78' Northing = 936,087.25' Easting = 2,049,149.78' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 625 620 615 610 605 600 595 590 CAVING> PIEZOMETER NO. PZ-126BSheet 1 of 1 3-12-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:7.49 PIEZOMETER NO. PZ-126B START: 3-11-21 629.78ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Stiff, tan/brown, moist, fine sandy SILT - (Residuum) PARTIALLY WEATHERED ROCK sampled as very dense, gray, moist,silty, fine to coarse SAND with gravel PARTIALLY WEATHERED ROCK sampled as very dense, gray, dry, fineto coarse, sandy, andesite GRAVEL Auger refusal at 8.5 feet below ground surface. No groundwaterencountered at time of drilling. 259 50/2" 50/0.5" 50/0.5" SOIL DESCRIPTION SOILTYPE SAMPLESLOCATION: DRILLER: DRILLING METHOD: 615 610 605 600 595 590 585 580 CAVING> BORING NO. B-127Sheet 1 of 1 3-11-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:Dry BORING NO. B-127 START: 3-11-21 616.63ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_NOWELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT Stiff, light brown, moist, fine tomedium sandy SILT - (RESIDUUM) Stiff, red and gray, moist, fine tomedium sandy SILT with traceclay Dense, gray, moist, silty fine tocoarse SAND PARTIALLY WEATHERED ROCKsampled as very dense, gray,moist, silty fine to coarse SAND PARTIALLY WEATHERED ROCKsampled as andesite GRAVEL Auger refusal at 15.0 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 4.79 feet belowground surface. 237 236 91321 101650/4" Grout, 0 to 2.0 feet Bentonite seal, 2.0 to 6.0 feet Filter pack, sand 6.0 to 15.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 8.5to 13.5 feet Pipe cap 0.33 feetTotal well depth, 13.83 feet SURFACE COMPLETION 2.45-foot PVC stick-up with a venthole.Top of PVC casing elev. = 629.46' Ground surface elev. = 627.01' Northing = 935,973.58' Easting = 2,049,016.06' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 625 620 615 610 605 600 595 590 CAVING> PIEZOMETER NO. PZ-128BSheet 1 of 1 3-12-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:4.79 PIEZOMETER NO. PZ-128B START: 3-10-21 627.01ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/4" Firm, brown, moist, fine tomedium sandy SILT - (RESIDUUM) Very stiff, light brown, moist, fineto medium sandy SILT with quartzgravel Dense, gray, dry, silty, fine tocoarse SAND PARTIALLY WEATHERED ROCKsampled as very dense, gray, dry,silty, fine to coarse SAND PARTIALLY WEATHERED ROCK sampled as very dense, gray, dry, fine to coarse sandy, andesite GRAVEL PARTIALLY WEATHERED ROCKsampled as andesite GRAVEL Auger refusal at 18.83 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 5.52 feet belowground surface. 234 3810 81518 92850/3" 50/2" 50/0.5" Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 11.0 feet Filter pack, sand 11.0 to 18.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 13.5to 18.5 feet Pipe cap 0.33 feetTotal well depth, 18.83 feet SURFACE COMPLETION 2.69-foot PVC stick-up with a venthole. Top of PVC casing elev. = 635.11' Ground surface elev. = 632.42' Northing = 935,938.12' Easting = 2,049,240.22' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 630 625 620 615 610 605 600 595 CAVING> PIEZOMETER NO. PZ-129BSheet 1 of 1 3-12-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:5.52 PIEZOMETER NO. PZ-129B START: 3-10-21 632.42ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/3" Soft, brown/red/tan, moist, fine to coarse sandy, clayey SILT - (RESIDUUM) Very stiff, brown, moist, fine to medium sandy SILT with trace gravel PARTIALLY WEATHERED ROCK sampled as very dense, gray, moist,fine to medium sandy, clayey rhyolite GRAVEL Auger refusal at 12.0 feet below ground surface. No groundwater encountered at time of drilling. 222 1912 50/3" 50/2" 50/0" SOIL DESCRIPTION SOILTYPE SAMPLESLOCATION: DRILLER: DRILLING METHOD: 620 615 610 605 600 595 590 585 CAVING> BORING NO. B-130Sheet 1 of 1 3-10-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:Dry BORING NO. B-130 START: 3-10-21 623.88ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_NOWELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT Soft, tan, moist, fine, sandy,clayey SILT - (RESIDUUM) PARTIALLY WEATHERED ROCK sampled as very dense, light brown, dry, fine to coarse SAND PARTIALLY WEATHERED ROCK sampled as very dense, tan/gray,dry, silty rhyolite GRAVEL PARTIALLY WEATHERED ROCKsampled as very dense, tan/gray,dry, silty, fine to coarse sandy rhyolite GRAVEL Auger refusal at 18.5 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 12.85 feet belowground surface. 122 1250/3" 50/1" 50/3" 50/3" 50/1" Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 11.0 feet Filter pack, sand 11.0 to 18.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 13.0to 18.0 feet Pipe cap 0.33 feetTotal well depth, 18.33 feet SURFACE COMPLETION 2.54-foot PVC stick-up with a venthole.Top of PVC casing elev. = 618.60' Ground surface elev. = 616.06' Northing = 935,888.94' Easting = 2,049,591.10' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 615 610 605 600 595 590 585 580 CAVING> PIEZOMETER NO. PZ-131ABSheet 1 of 1 3-12-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:12.85 PIEZOMETER NO. PZ-131AB START: 3-10-21 616.06ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/3" No samples PARTIALLY WEATHERED ROCK Auger refusal at 28.5 feet below ground surface. No groundwaterat time of drilling, after 24 hoursgroundwater was encountered at7.57 feet below ground surface. 347 81823 173842 50/5" 50/5" 50/4" 50/2" 50/0" Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 14.0 feet Filter pack, sand 14.0 to 28.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 16.0to 26.0 feet Pipe cap 0.33 feetTotal well depth, 26.33 feet SURFACE COMPLETION 2.40-foot PVC stick-up with a venthole.Top of PVC casing elev. = 622.66' Ground surface elev. = 620.26' Northing = 935,784.68' Easting = 2,049,904.99' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 620 615 610 605 600 595 590 585 CAVING> PIEZOMETER NO. PZ-132BSheet 1 of 1 3-12-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:7.57 PIEZOMETER NO. PZ-132B START: 3-11-21 620.26ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Very stiff, light brown, moist, SILTwith trace fine to coarse sand -(RESIDUUM) PARTIALLY WEATHERED ROCK sampled as very dense, light brown, moist, silty, fine to medium SAND PARTIALLY WEATHERED ROCK sampled as very dense, black andwhite, moist, clayey, gravely,medium to coarse SAND PARTIALLY WEATHERED ROCKsampled as very dense, black andwhite, moist, clayey rhyoliteGRAVEL PARTIALLY WEATHERED ROCKsampled as very dense, light gray,dry, fine to coarse sandy rhyolite GRAVEL Auger refusal at 13.5 feet below ground surface. No groundwater encountered at time of drilling, after 24 hours groundwater was encountered at 4.44 feet below ground surface. 1317 3850/5" 50/2" 50/1" 50/0" Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 5.0 feet Filter pack, sand 5.0 to 13.5 feet 2-inch diameter, 0.010-inch slotted Schedule 40 PVC well screen, 7.0to 12.0 feet Pipe cap 0.33 feetTotal well depth, 12.33 feet SURFACE COMPLETION 2.70-foot PVC stick-up with a venthole. Top of PVC casing elev. = 630.34' Ground surface elev. = 627.64' Northing = 935,805.43' Easting = 2,049,173.42' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 625 620 615 610 605 600 595 590 CAVING> PIEZOMETER NO. PZ-133BSheet 1 of 1 3-26-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:4.44 PIEZOMETER NO. PZ-133B START: 3-11-21 627.64ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/5" Very stiff, light brown, moist, SILTwith trace fine to coarse sand PARTIALLY WEATHERED ROCK sampled as very dense, light brown, moist, silty, fine to medium SAND PARTIALLY WEATHERED ROCK sampled as very dense,blackened white, moist, clayey,gravely, medium to coarse SAND PARTIALLY WEATHERED ROCKsampled as very dense, black andwhite, moist, clayey GRAVEL PARTIALLY WEATHERED ROCKsampled as very dense, light gray,dry, fine to coarse sandy GRAVEL Moderately hard, moderately severe weathering, felsic (light gray), aphantic, RHYOLITE, close fractures, moderate to steep angle, Mg staining.R-1 recovery = 66% RQD = 43% Moderately hard, moderatelysevere weathering, felsic (lightgray), aphantic, RHYOLITE, closefractures, moderate to steepangle, Mg staining with CLAYR-2 recovery = 99% RQD = 81.4% Auger refusal at 13.5 feet below ground surface.Boring terminated at 23.5 feetbelow ground surface. Nogroundwater encountered at timeof drilling, after 24 hoursgroundwater was encountered at1.93 feet below ground surface. 1317 3850/5" 50/2" 50/1" 50/0"R-1 R-2 Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 15.0 feet Filter pack, sand 15.0 to 23.5 feet 2-inch diameter, 0.010-inch slotted Schedule 40 PVC well screen, 17.0to 22.0 feet Pipe cap 0.33 feetTotal well depth, 22.33 feet SURFACE COMPLETION 2.30-foot PVC stick-up with a venthole.Top of PVC casing elev. = 629.31' Ground surface elev. = 627.01' Northing = 935,803.12' Easting = 2,049,179.07' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 625 620 615 610 605 600 595 590 CAVING> PIEZOMETER NO. PZ-133CSheet 1 of 1 3-26-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA and NQ Core J21-1003-81 AFTER 24 HOURS:1.93 PIEZOMETER NO. PZ-133C START: 3-11-21 627.01ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/5" Firm, yellow/tan, moist, clayey,fine to coarse sandy SILT -(RESIDUUM) Very hard, tan, dry, fine tomedium sandy SILT PARTIALLY WEATHERED ROCKsampled as very hard, tan, moist,fine to medium sandy, clayey SILT PARTIALLY WEATHERED ROCK sampled as moderately hard, moderately severe gray porphoritic rhyolite GRAVEL PARTIALLY WEATHERED ROCK sampled as very hard, tan, dry, clayey, fine to coarse sandy SILT PARTIALLY WEATHERED ROCKsampled as very dense, light gray,dry, rhyolite GRAVEL Auger refusal at 22.0 feet belowground surface. No groundwaterencountered at time of drilling, after 24 hours groundwater was encountered at 17.74 feet below ground surface. 224 24050/5" 50/4" 50/4" 50/0" 50/1.5" 50/0" Grout, 0 to 3.0 feet Bentonite seal, 3.0 to 11.0 feet Filter pack, sand 11.0 to 22.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 15.7 to 20.7 feet Pipe cap 0.33 feetTotal well depth, 21.03 feet SURFACE COMPLETION 2.60-foot PVC stick-up with a venthole.Top of PVC casing elev. = 619.94' Ground surface elev. = 617.34' Northing = 935,787.95' Easting = 2,049,409.19' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 615 610 605 600 595 590 585 580 CAVING> PIEZOMETER NO. PZ-134ABSheet 1 of 1 3-10-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:17.74 PIEZOMETER NO. PZ-134AB START: 3-9-21 617.34ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/5" Hard, white/yellow, tan, dry, fineto medium sandy SILT -(RESIDUUM) PARTIALLY WEATHERED ROCK sampled as very hard, white/yellow, tan, dry, fine to medium sandy SILT PARTIALLY WEATHERED ROCK sampled as very dense,white/black, dry, moderatelysevere weathered, rhyoliteGRAVEL PARTIALLY WEATHERED ROCKsampled as very hard, tan, dry,fine to coarse sandy SILT PARTIALLY WEATHERED ROCKsampled as tan/white, dry, verysoft, moderately severe weathered rhyolite GRAVEL Auger refusal at 23.6 belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 7.42 feet belowground surface. 31029 2550/3" 50/1" 50/3" 50/.5" 50/3" 50/1" Grout, 0 to 5.0 feet Bentonite seal, 5.0 to 16.0 feet SURFACE COMPLETION 2.40-foot PVC stick-up with a venthole.Top of PVC casing elev. = 614.25' Ground surface elev. = 611.85' Northing = 935,715.27' Easting = 2,049,509.66' Filter pack, sand 16.0 to 23.6 feet 2-inch diameter, 0.010-inch slotted Schedule 40 PVC well screen, 18.0to 23.0 feet Pipe cap 0.33 feetTotal well depth, 23.33 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 610 605 600 595 590 585 580 575 CAVING> PIEZOMETER NO. PZ-135BSheet 1 of 1 3-10-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:7.42 PIEZOMETER NO. PZ-135B START: 3-9-21 611.85ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/3" Very stiff, light brown, gray, moist,sandy CLAY with trace gravel -(RESIDUUM) PARTIALLY WEATHERED ROCKsampled as soft, moderately tosevere weathered rhyoliticGRAVEL PARTIALLY WEATHERED ROCKsampled as very dense, light gray,dry, fine to coarse sandy,rhyolitic, soft, severely weatheredGRAVEL PARTIALLY WEATHERED ROCKsampled as very dense light gray,dry, very soft, very severely weathered, rhyolitic GRAVEL Auger refusal at 13.5 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 5.39 feet belowground surface. 1512 50/3" 50/1" 50/2" 50/0" Grout, 0 to 2.0 feet Bentonite seal, 2.0 to 5.0 feet Filter pack, sand 5.0 to 13.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 6.5to 11.5 feet Pipe cap 0.33 feet Total well depth, 11.83 feet SURFACE COMPLETION 2.35-foot PVC stick-up with a venthole.Top of PVC casing elev. = 602.67' Ground surface elev. = 600.32' Northing = 935,770.97' Easting = 2,049,813.60' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 600 595 590 585 580 575 570 565 CAVING> PIEZOMETER NO. PZ-136BSheet 1 of 1 3-10-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:5.39 PIEZOMETER NO. PZ-136B START: 3-9-21 600.32ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Firm, gray, dry, gravely, silty, fineto coarse SAND - (RESIDUUM) PARTIALLY WEATHERED ROCKsampled as very dense, moist,gravely, silty, fine to coarse SAND PARTIALLY WEATHERED ROCKsampled as moderately hard,moderately weathering, aphantictexture RHYOLITE GRAVEL Very dense, light brown, moist,silty, fine to coarse SAND Very dense, light brown, dry, silty,fine to medium SAND PARTIALLY WEATHERED ROCKsampled as very dense, lightbrown, dry, silty, fine to mediumSAND Auger refusal at 19.0 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 10.44 feet belowground surface. 288 50/4" 50/1" 192441 272936 3750/0" Grout, 0 to 5.0 feet Bentonite seal, 5.0 to 11.0 feet Filter pack, sand 11.0 to 19.0 feet 2-inch diameter, 0.010-inch slotted Schedule 40 PVC well screen, 13.0to 18.0 feet Pipe cap 0.33 feetTotal well depth, 18.33 feet SURFACE COMPLETION 2.33-foot PVC stick-up with a venthole.Top of PVC casing elev. = 614.66' Ground surface elev. = 612.33' Northing = 935,499.78' Easting = 2,049,971.49' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 610 605 600 595 590 585 580 575 CAVING> PIEZOMETER NO. PZ-137BSheet 1 of 1 3-23-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:10.44 PIEZOMETER NO. PZ-137B START: 3-17-21 612.33ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/0" Firm, tan, moist SILT with traceclay - (RESIDUUM) Very stiff, tan and gray moist, fineto coarse sandy SILT Dense, gray, dry, silty, fine tocoarse SAND PARTIALLY WEATHERED ROCKsampled as very dense, tan, dry,silty, fine to coarse SAND PARTIALLY WEATHERED ROCKsampled as very hard, brown,moist, fine to coarse sandy SILT with trace clay PARTIALLY WEATHERED ROCK sampled as very dense, brown, dry, silty, fine to coarse SAND PARTIALLY WEATHERED ROCK sampled as very dense, lightbrown/gray, wet, clayey, gravelly,medium to coarse SAND PARTIALLY WEATHERED ROCKsampled as very dense, gray, dry,rhyolite GRAVEL Auger refusal at 29.0 feet below ground surface. No groundwater encountered at time of drilling, after 24 hours groundwater was encountered at 9.19 feet belowground surface. 225 5713 121721 50/3" 2750/5" 3750/3" 2950/5" 50/1" Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 11.0 feet Filter pack, sand 11.0 to 29.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 18.0to 28.0 feet Pipe cap 0.33 feetTotal well depth, 28.33 feet SURFACE COMPLETION 2.65-foot PVC stick-up with a venthole.Top of PVC casing elev. = 611.32' Ground surface elev. = 608.67' Northing = 935,494.91' Easting = 2,049,183.51' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 605 600 595 590 585 580 575 570 CAVING> PIEZOMETER NO. PZ-138BSheet 1 of 1 3-23-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:9.19 PIEZOMETER NO. PZ-138B START: 3-18-21 608.67ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/5" 50/3" 50/5" PARTIALLY WEATHERED ROCKsampled as very hard, lightbrown/gray, moist, fine to coarsesandy SILT with trace clay -(RESIDUUM) Soft, moderately severe weathering, purple, porphoritic with chlorite phenocrysts, ANDESITE, close fractures, moderately dipping, filled with white clay, massive bedding. R-1 recovery = 94% RQD = 90% Soft, moderately severeweathering, purple, porphoriticwith chlorite phenocrysts,ANDESITE, close fractures,moderately dipping, filled withwhite clay, massive bedding. R-2 recovery = 94% RQD = 75.8% Soft, moderately severeweathering, purple, porphoriticwith chlorite phenocrysts, ANDESITE, close fractures, moderately dipping, filled with white clay, massive bedding. R-3 recovery = 7% RQD = 0% Auger refusal at 4.0 feet below ground surface. No groundwaterencountered at time of drilled.Boring terminated at 14.5 feetbelow ground surface. Nogroundwater encountered at timeof drilling, after 24 hoursgroundwater was encountered at0.31 feet below ground surface. Note: 2 offset soil borings drilledreaching 5.0 and 7.5 feet belowground surface. 350/3" R-1 R-2 R-3 Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 7.0 feet Filter pack, sand 11.0 to 14.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 9.0 to 14.0 feet Pipe cap 0.33 feet Total well depth, 14.33 feet SURFACE COMPLETION 2.55-foot PVC stick-up with a venthole. Top of PVC casing elev. = 608.30' Ground surface elev. = 605.75' Northing = 935,496.49' Easting = 2,049,515.52' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 605 600 595 590 585 580 575 570 CAVING> PIEZOMETER NO. PZ-139CSheet 1 of 1 3-5-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA and NQ Core J21-1003-81 AFTER 24 HOURS:0.31 PIEZOMETER NO. PZ-139C START: 3-5-21 605.75ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/3" Firm, red/gray, damp, clayey SILT- (RESIDUUM) Stiff, red/gray, damp, clayey SILT Firm, red/gray, damp, clayey SILT Soft, red/gray, damp, clayey SILT Hard, brown/black, damp, silty CLAY Very stiff, light brown/black, wet,fine to coarse sandy CLAY Firm, light brown/gray/black,damp, fine to coarse sandy SILT Dense, light brown/gray, damp, silty, fine to medium SAND PARTIALLY WEATHERED ROCKsampled as very hard, lightbrown/red/yellow, damp, fine to coarse sandy SILT Auger refusal at 35.0 feet belowground surface. Groundwaterencountered at 29.56 feet belowground surface at time of drilling,after 24 hours groundwater wasencountered at 9.27 feet belowground surface. 334 358 224 UD-1123 31617 589 UD-2224 81628 203650/6" Grout, 0 to 5.0 feet Bentonite seal, 5.0 to 20.0 feet Filter pack, sand 20.0 to 35.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 22.0to 32.0 feet Pipe cap 0.33 feetTotal well depth, 32.33 feet SURFACE COMPLETION 2.32-foot PVC stick-up with a venthole.Top of PVC casing elev. = 606.60' Ground surface elev. = 604.28' Northing = 935,456.53' Easting = 2,049,806.35' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 600 595 590 585 580 575 570 565 CAVING> PIEZOMETER NO. PZ-140BSheet 1 of 1 3-5-21 DEPTH TO - WATER> INITIAL: CLIENT: 29.56 PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:9.27 PIEZOMETER NO. PZ-140B START: 3-5-21 604.28ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/6" Stiff, white/tan, moist, clayey SILTwith trace sand - (FILL) Firm, white/gray, moist, clayey,fine to coarse SAND -(RESIDUUM) PARTIALLY WEATHERED ROCKsampled as very dense,white/gray, dry, silty, fine tocoarse SAND with gravel PARTIALLY WEATHERED ROCKsampled as very dense,white/gray, dry, silty, fine tocoarse SAND with trace clay Very dense, white/gray, moist,clayey, fine to coarse SAND withtrace gravel PARTIALLY WEATHERED ROCK sampled as very dense, white/gray, moist, clayed fine to coarse sandy, rhyolite GRAVEL Auger refusal at 22.0 feet belowground surface. No groundwaterencountered at time of drilling, after 24 hours groundwater was encountered at 1.90 feet below ground surface. 256 3711 2350/4" 50/3" 123742 50/1" Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 14.0 feet Filter pack, sand 14.0 to 22.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 16.0 to 21.0 feet Pipe cap 0.33 feetTotal well depth, 21.33 feet SURFACE COMPLETION 1.63-foot PVC stick-up with a venthole.Top of PVC casing elev. = 594.14' Ground surface elev. = 592.51' Northing = 935,492.70' Easting = 2,049,017.14' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 590 585 580 575 570 565 560 555 CAVING> PIEZOMETER NO. PZ-141BSheet 1 of 1 3-9-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:1.90 PIEZOMETER NO. PZ-141B START: 3-9-21 592.51ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/4" Firm, tan/gray/red, moist, fine tomedium sandy CLAY -(RESIDUUM) Very hard, white, dry, fine tocoarse sandy SILT with trace clay PARTIALLY WEATHERED ROCKsampled as very dense, tan/gray,dry, silty, fine to coarse SAND PARTIALLY WEATHERED ROCKsampled as very dense,brown/tan, dry, rhyolitic GRAVEL PARTIALLY WEATHERED ROCKsampled as very dense,brown/tan, dry, silty SAND with trace gravel PARTIALLY WEATHERED ROCKsampled as rhyolitic GRAVEL Auger refusal at 20.0 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 4.26 feet belowground surface. 125 362732 50/3" 50/0.5" 50/0.5" 50/0.5" Grout, 0 to 4.9 feet Bentonite seal, 4.9 to 12.5 feet Filter pack, sand 12.5 to 20.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 13.3 to 18.3 feet Pipe cap 0.33 feetTotal well depth, 18.63 feet SURFACE COMPLETION 2.35-foot PVC stick-up with a venthole. Top of PVC casing elev. = 590.92' Ground surface elev. = 588.57' Northing = 935,611.80' Easting = 2,050,138.05' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 585 580 575 570 565 560 555 550 CAVING> PIEZOMETER NO. PZ-142BSheet 1 of 1 3-5-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:4.26 PIEZOMETER NO. PZ-142B START: 3-5-21 588.57ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES No samples PARTIALLY WEATHERED ROCK Auger refusal at 18.5 feet below ground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 2.52 feet belowground surface. 245 51126 183132 101125 50/3" 50/1" Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 12.0 feet Filter pack, sand 12.0 to 18.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 13.1to 18.1 feet Pipe cap 0.33 feet Total well depth, 18.43 feet SURFACE COMPLETION 2.35-foot PVC stick-up with a venthole.Top of PVC casing elev. = 585.75' Ground surface elev. = 583.40' Northing = 935,472.70' Easting = 2,049,279.46' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 580 575 570 565 560 555 550 545 CAVING> PIEZOMETER NO. PZ-143BSheet 1 of 1 3-8-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:2.52 PIEZOMETER NO. PZ-143B START: 3-3-21 583.40ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Stiff, brown, moist SILT - (FILL) Firm, red and gray, moist SILTwith trace clay - (RESIDUUM) Firm, light brown, moist SILT withtrace clay Very stiff, light brown, moist SILTwith trace clay PARTIALLY WEATHERED ROCKsampled as very dense, gray,moist to wet, sandy, clayey, andesite GRAVEL No Recovery Auger refusal at 19.0 feet below ground surface. No groundwater encountered at time of drilling, after 24 hours groundwater was encountered at 4.77 feet below ground surface. 247 123 225 457 50/1" 50/0" Grout, 0 to 5.0 feet Bentonite seal, 5.0 to 11.0 feet Filter pack, sand 11.0 to 19.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 13.0to 18.0 feet Pipe cap 0.33 feetTotal well depth, 18.33 feet SURFACE COMPLETION 2.53-foot PVC stick-up with a venthole.Top of PVC casing elev. = 614.45' Ground surface elev. = 611.92' Northing = 935,269.70' Easting = 2,048,884.46' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 610 605 600 595 590 585 580 575 CAVING> PIEZOMETER NO. PZ-144BSheet 1 of 1 3-23-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:4.77 PIEZOMETER NO. PZ-144B START: 3-18-21 611.92ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Loose, tan, moist, silty, fine SAND- (RESIDUUM) PARTIALLY WEATHERED ROCK sampled as very dense, tan, dry, silty, fine to coarse SAND with trace gravel PARTIALLY WEATHERED ROCKsampled as soft, very severeweathering, tan, aphaniticRHYOLITE GRAVEL with slightMg staining PARTIALLY WEATHERED ROCKsampled as very dense, tan, dry,fine to coarse SAND with quartz and rhyolite gravel PARTIALLY WEATHERED ROCKsampled as very dense, tan, dry,fine to coarse SAND with very severe to complete weathered rhyolite gravel Auger refusal at 18.5 feet below ground surface. No groundwater encountered at time of drilling, after 24 hours groundwater was encountered at 13.85 feet belowground surface. 235 1050/5" 50/5" 50/3" 50/2" 50/0" Grout, 0 to 5.0 feet Bentonite seal, 5.0 to 11.0 feet Filter pack, sand 11.0 to 18.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 13.0to 18.0 feet Pipe cap 0.33 feetTotal well depth, 18.33 feet SURFACE COMPLETION 2.12-foot PVC stick-up with a venthole.Top of PVC casing elev. = 606.62' Ground surface elev. = 604.50' Northing = 935,286.79' Easting = 2,049,171.74' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 600 595 590 585 580 575 570 565 CAVING> PIEZOMETER NO. PZ-145BSheet 1 of 1 3-23-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:13.85 PIEZOMETER NO. PZ-145B START: 3-18-21 604.50ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/5" Firm, light brown, moist, fine tomedium sandy SILT with tracegravel - (RESIDUUM) Stiff, light brown and gray, moist,fine to medium sandy SILT PARTIALLY WEATHERED ROCKsampled as very dense, lightbrown, dry, fine to coarse SAND Auger refusal at 9.0 feet below ground surface. No groundwater encountered at time of drilling, after 24 hours groundwater was encountered at 7.10 feet below ground surface. 124 246 50/1" 50/0" Grout, 0 to 2.0 feet Bentonite seal, 2.0 to 3.0 feet Filter pack, sand 3.0 to 9.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 3.30to 8.30 feet Pipe cap 0.33 feet Total well depth, 8.63 feet SURFACE COMPLETION 2.49-foot PVC stick-up with a venthole.Top of PVC casing elev. = 601.84' Ground surface elev. = 599.35' Northing = 935,278.11' Easting = 2,049,348.26' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 595 590 585 580 575 570 565 560 CAVING> PIEZOMETER NO. PZ-146ABSheet 1 of 1 3-23-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:7.10 PIEZOMETER NO. PZ-146AB START: 3-19-21 599.35ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Firm, red, moist, fine, sandy, siltyCLAY - (RESIDUUM) Dense, gray/white, dry, silty, fineto coarse SAND with trace gravel Dense, gray/red, dry, silty, fine tocoarse SAND Dense, gray/red, dry, silty, fine tocoarse SAND with trace clay Very stiff, tan, moist, fine tocoarse sandy SILT PARTIALLY WEATHERED ROCKsampled as very dense, white andtan, moist, silty fine to coarse SAND with gravel PARTIALLY WEATHERED ROCKsampled as very dense,gray/brown, moist, clayey, silty, fine to coarse SAND with fractured quartz gravel Auger refusal at 29.5 below ground surface. Groundwater encountered at 27.90 feet below ground surface at time of drilling, after 24 hours groundwater wasencountered at 11.68 feet belowground surface. 134 162124 101926 101921 111413 344350/5" 3250/4" 4550/3" Grout, 0 to 5.25 feet Bentonite seal, 5.25 to 15.5 feet SURFACE COMPLETION 2.44-foot PVC stick-up with a venthole.Top of PVC casing elev. = 616.69' Ground surface elev. = 614.25' Northing = 935,275.47' Easting = 2,049,608.34' Filter pack, sand 15.5 to 29.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 18.5to 28.5 feet Pipe cap 0.33 feetTotal well depth, 28.83 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 610 605 600 595 590 585 580 575 CAVING> PIEZOMETER NO. PZ-147BSheet 1 of 1 3-8-21 DEPTH TO - WATER> INITIAL: CLIENT: 27.90 PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:11.68 PIEZOMETER NO. PZ-147B START: 3-8-21 614.25ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/5" 50/4" 50/3" Stiff, light brown/white, damp,clayey SILT - (RESIDUUM) Stiff, light brown, damp, very finesandy SILT Stiff, light brown/red/gray, damp,very fine sandy, clayey SILT Firm, light brown/red, moist, finesandy, clayey SILT Very stiff, brown, black, gray,moist, fine sandy, clayey SILT Stiff, light brown, damp, finesandy, clayey SILT Very stiff, light brown, damp, finesandy SILT Firm, light brown/black, gray,damp, fine to medium sandy SILT Very hard, light gray/yellow/lightbrown, dry, fine sandy SILT 345 UD-1236 356 366 UD-2123 18520 UD-3359 51017 334 91248 Grout, 0 to 5.25 feet Bentonite seal, 5.25 to 26.0 feet SURFACE COMPLETION 2.10-foot PVC stick-up with a venthole.Top of PVC casing elev. = 609.06' Ground surface elev. = 606.96' Northing = 935,331.14' Easting = 2,049,785.76' Filter pack, sand 26.0 to 40.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 28.5to 38.5 feet Pipe cap 0.33 feetTotal well depth, 38.83 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 605 600 595 590 585 580 575 570 CAVING> PIEZOMETER NO. PZ-148BSheet 1 of 2 3-8-21 DEPTH TO - WATER> INITIAL: CLIENT: 24.09 PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:12.05 PIEZOMETER NO. PZ-148B START: 3-4-21 606.96ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Boring terminated at 40.0 feetbelow ground surface.Groundwater encountered at24.09 feet below ground surfaceat time of drilling, after 24 hoursgroundwater was encountered at12.05 feet below ground surface. DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 565 560 555 550 545 540 535 530 CAVING> PIEZOMETER NO. PZ-148BSheet 2 of 2 3-8-21 DEPTH TO - WATER> INITIAL: CLIENT: 24.09 PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 45 50 55 60 65 70 75 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:12.05 PIEZOMETER NO. PZ-148B START: 3-4-21 606.96ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Soft, brown, moist, fine to coarsesandy, clayey SILT - (RESIDUUM) Soft, brown, moist, fine tomedium sandy SILT PARTIALLY WEATHERED ROCKsampled as very dense, brown,moist, silty, fine to coarse SAND PARTIALLY WEATHERED ROCKsampled as very dense, tan, dry,silty, fine to coarse SAND PARTIALLY WEATHERED ROCKsampled as very dense, tan, dry,silty, fine to coarse SAND with gravel Auger refusal at 18.5 feet below ground surface. No groundwater encountered at time of drilling, after 24 hours groundwater was encountered at 4.90 feet below ground surface. 113 222 50/2" 50/2" 50/1" 50/0.5" Grout, 0 to 4.8 feet Bentonite seal, 4.8 to 9.6 feet Filter pack, sand 9.6 to 18.5 feet 2-inch diameter, 0.010-inch slotted Schedule 40 PVC well screen, 12.0to 17.0 feet Pipe cap 0.33 feetTotal well depth, 17.33 feet SURFACE COMPLETION 2.72-foot PVC stick-up with a venthole.Top of PVC casing elev. = 598.89' Ground surface elev. = 596.17' Northing = 935,277.44' Easting = 2,049,002.56' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 595 590 585 580 575 570 565 560 CAVING> PIEZOMETER NO. PZ-149BSheet 1 of 1 3-8-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:4.90 PIEZOMETER NO. PZ-149B START: 3-4-21 596.17ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES No samples PARTIALLY WEATHERED ROCK Auger refusal at 18.5 feet below groud surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 7.30 feet belowground surface. 5710 102723 247 91521 50/4" 50/1" Grout, 0 to 5.0 feet Bentonite seal, 5.0 to 11.0 feet Filter pack, sand 11.0 to 18.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 13.0to 18.0 feet Pipe cap 0.33 feetTotal well depth, 18.33 feet SURFACE COMPLETION 1.9-foot PVC stick-up with a venthole.Top of PVC casing elev. = 595.34' Ground surface elev. = 593.44' Northing = 935,256.65' Easting = 2,050,198.41' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 590 585 580 575 570 565 560 555 CAVING> PIEZOMETER NO. PZ-150BSheet 1 of 1 3-8-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:7.30 PIEZOMETER NO. PZ-150B START: 3-3-21 593.44ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Soft, black, brown, tan, moist, fineto medium sandy CLAY - (FILL) Firm, tan, dry, silty, fine tomedium SAND with organics -(RESIDUUM) Firm, tan, moist, clayey, fine tomedium SAND Very firm, white/gray, dry, silty,fine to coarse SAND PARTIALLY WEATHERED ROCKsampled as very dense,white/gray, dry, silty, fine to coarse SAND with trace clay PARTIALLY WEATHERED ROCKsampled as very dense,white/gray, dry, fine to coarse SAND with gravel Auger refusal at 18.5 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 3.19 feet belowground surface. 113 3512 799 111517 50/1" 50/0.5" Grout, 0 to 5.0 feet Bentonite seal, 5.0 to 11.0 feet Filter pack, sand 11.0 to 18.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 13.0to 18.0 feet Pipe cap 0.33 feetTotal well depth, 18.33 feetSURFACE COMPLETION 2.52-foot PVC stick-up with a venthole.Top of PVC casing elev. = 596.14' Ground surface elev. = 593.62' Northing = 934,970.39' Easting = 2,049,074.61' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 590 585 580 575 570 565 560 555 CAVING> PIEZOMETER NO. PZ-151BSheet 1 of 1 3-23-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:3.19 PIEZOMETER NO. PZ-151B START: 3-23-21 593.62ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Firm, tan, moist, fine sandy SILT -(RESIDUUM) Very firm, gray, dry, silty, fine tocoarse SAND PARTIALLY WEATHERED ROCKsampled as very dense, gray,silty, fine to coarse SAND withandesite gravel PARTIALLY WEATHERED ROCKsampled as moderatley hard,moderately severe weathereddark and light gray, porphoriticandesite GRAVEL Auger refusal at 8.5 feet below ground surface. No groundwater encountered at time of drilling, after 24 hours groundwater was encountered at 1.89 feet below ground surface. 126 81114 50/1" 50/0" Grout, 0 to 1.0 feet Bentonite seal, 1.0 to 2.0 feet Filter pack, sand 2.0 to 8.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 3.0to 8.0 feet Pipe cap 0.33 feetTotal well depth, 8.33 feetSURFACE COMPLETION 2.50-foot PVC stick-up with a venthole.Top of PVC casing elev. = 599.61' Ground surface elev. = 597.11' Northing = 935,020.81' Easting = 2,049,319.32' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 595 590 585 580 575 570 565 560 CAVING> PIEZOMETER NO. PZ-152BSheet 1 of 1 3-25-21 DEPTH TO - WATER> INITIAL: CLIENT: PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:1.89 PIEZOMETER NO. PZ-152B START: 3-22-21 597.11ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Firm, light brown and gray, moist,fine to medium sandy SILT -(RESIDUUM) Stiff, light brown and gray, moist,fine to medium sandy SILT Stiff, light brown and white, moist,fine to medium sandy SILT Stiff, white, moist, fine to mediumsandy SILT with trace clay Firm, brown and black, moist, silty, fine SAND Stiff, dark gray, moist SILT Very stiff, light brown, moist SILT Auger refusal at 33.5 feet below ground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 6.92 feet belowground surface. 124 237 345 579 598 359 355 121514 50/0" Grout, 0 to 5.0 feet Bentonite seal, 5.0 to 21.0 feet SURFACE COMPLETION 2.76-foot PVC stick-up with a venthole. Top of PVC casing elev. = 602.12' Ground surface elev. = 599.36' Northing = 934,989.48' Easting = 2,049,521.50' Filter pack, sand 21.0 to 33.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 23.0to 33.0 feet Pipe cap 0.33 feetTotal well depth, 33.33 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 595 590 585 580 575 570 565 560 CAVING> PIEZOMETER NO. PZ-153BSheet 1 of 1 3-23-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:6.92 PIEZOMETER NO. PZ-153B START: 3-19-21 599.36ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Very stiff, light brown, slightlymoist, fine to coarse sandy SILTwith trace gravel - (RESIDUUM) Dense, light brown, slightly moist,silty fine SAND Dense, white and gray, slightlymoist, silty fine SAND Very firm, white, moist, silty, fineto coarse SAND with trace gravel PARTIALLY WEATHERED ROCK sampled as very dense, light grayish brown, slightly moist, silty, fine to medium SAND PARTIALLY WEATHERED ROCKsampled as very dense, lightgrayish brown, slightly moist, silty, fine to coarse SAND Auger refusal at 23.5 feet below ground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 5.26 feet belowground surface. 489 141021 101918 51115 1350/5" 341850/3" 50/1" Grout, 0 to 3.0 feet Bentonite seal, 3.0 to 15.0 feet SURFACE COMPLETION 2.0-foot PVC stick-up with a venthole.Top of PVC casing elev. = 597.40' Ground surface elev. = 595.40' Northing = 934,961.46' Easting = 2,049,714.41' Filter pack, sand 15.0 to 23.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 17.5to 22.5 feet Pipe cap 0.33 feetTotal well depth, 22.83 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 595 590 585 580 575 570 565 560 CAVING> PIEZOMETER NO. PZ-154BSheet 1 of 1 3-8-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:5.26 PIEZOMETER NO. PZ-154B START: 3-3-21 595.40ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/5" 50/3" Firm, red/brown, moist, fine sandySILT - (RESIDUUM) Firm, white/tan, moist, clayey, finesandy SILT Hard, white/tan, moist, fine tocoarse sandy SILT with gravel Very hard, light brown/gray, dry,fine sandy SILT PARTIALLY WEATHERED ROCKsampled as very hard, lightbrown/gray, dry, fine sandy SILT PARTIALLY WEATHERED ROCKsampled as very hard, lightbrown/gray, moist, fine to coarse sandy SILT with gravel PARTIALLY WEATHERED ROCK sampled as very dense, gray, dry,fine to coarse SAND with gravel Auger refusal at 25.0 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 5.89 feet belowground surface. 233 334 81320 82733 53/6" 50/3" 50/1" Grout, 0 to 3.75 feet Bentonite seal, 3.75 to 15.3 feet SURFACE COMPLETION 2.91-foot PVC stick-up with a venthole.Top of PVC casing elev. = 595.52' Ground surface elev. = 592.61' Northing = 934,964.60' Easting = 2,049,902.84' Filter pack, sand 15.3 to 25.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 17.5to 22.5 feet Pipe cap 0.33 feetTotal well depth, 22.83 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 590 585 580 575 570 565 560 555 CAVING> PIEZOMETER NO. PZ-155BSheet 1 of 1 3-8-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:5.89 PIEZOMETER NO. PZ-155B START: 3-4-21 592.61ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Dense, tan, dry, silty, gravely, fineto coarse SAND - (RESIDUUM) Very dense, tan, dry, silty, gravely,fine to coarse SAND PARTIALLY WEATHERED ROCK sampled as moderately hard, very severe to complete weathering, gray, aphanitic rhyolitic GRAVEL PARTIALLY WEATHERED ROCK sampled as very dense, tan, dry,gravely, fine to coarse SAND withtrace clay Boring terminated at 10.0 feetbelow ground surface. Nogroundwater encountered at timeof drilling, after 24 hoursgroundwater was encountered at2.76 feet below ground surface. 71827 232625 2350/5" 50/3" Grout, 0 to 2.0 feet Bentonite seal, 2.0 to 4.0 feet Filter pack, sand 4.0 to 10.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 4.4 to 9.4 feet Pipe cap 0.33 feetTotal well depth, 9.73 feet SURFACE COMPLETION 2.58-foot PVC stick-up with a venthole. Top of PVC casing elev. = 596.48' Ground surface elev. = 593.90' Northing = 934,909.11' Easting = 2,050,078.69' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 590 585 580 575 570 565 560 555 CAVING> PIEZOMETER NO. PZ-156ASheet 1 of 1 3-24-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:2.76 PIEZOMETER NO. PZ-156A START: 3-24-21 593.90ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/5" Dense, tan, dry, silty, gravely, fineto coarse SAND - (RESIDUUM) Very dense, tan, dry, silty, gravelyfine to coarse SAND PARTIALLY WEATHERED ROCKsampled as moderately hard, verysevere to complete weathering,gray, aphanitic, rhyolitic GRAVEL PARTIALLY WEATHERED ROCKsampled as very dense, tan, dry,gravely, fine to coarse SAND withtrace clay PARTIALLY WEATHERED ROCKsampled as very dense, tan, wet,gravely, clayey, fine to coarse SAND PARTIALLY WEATHERED ROCKsampled as very dense, lightbrown, wet, silty, fine SAND Auger refusal at 23.5 feet below ground surface. Groundwaterencountered at 12.19 feet belowground surface at time of drilling,after 24 hours groundwater wasencountered at 3.97 feet belowground surface. 71827 232625 2350/5" 50/3" 134250/4" 134150/1" 50/1" Grout, 0 to 5.0 feet Bentonite seal, 5.0 to 15.0 feet SURFACE COMPLETION 2.25-foot PVC stick-up with a venthole.Top of PVC casing elev. = 596.30' Ground surface elev. = 594.05' Northing = 934,911.48' Easting = 2,050,082.84' Filter pack, sand 15.0 to 23.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 17.5to 22.5 feet Pipe cap 0.33 feetTotal well depth, 22.83 feet DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 590 585 580 575 570 565 560 555 CAVING> PIEZOMETER NO. PZ-156BSheet 1 of 1 3-8-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:3.97 PIEZOMETER NO. PZ-156B START: 3-3-21 594.05ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/5" 50/4" 50/1" Stiff, light brown and gray, moist,fine to coarse sandy CLAY -(RESIDUUM) Very firm, gray, moist, silty fine tomedium SAND PARTIALLY WEATHERED ROCKsampled as very dense,gray/black/brown, dry, silty, fineto medium SAND Dense, gray/black/brown, moist,silty, fine to coarse SAND PARTIALLY WEATHERED ROCKsampled as dense,gray/black/brown, dry, silty, fine to coarse SAND PARTIALLY WEATHERED ROCK sampled as soft, very severweathering, black, phaneritic,ANDESITE, massive bedding Auger refusal at 18.5 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 0.64 feet belowground surface. 127 UD-181114 50/4" 71222 50/1" 50/0.5" Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 11.0 feet Filter pack, sand 11.0 to 18.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 13.0to 18.0 feet Pipe cap 0.33 feetTotal well depth, 18.33 feetSURFACE COMPLETION 2.85-foot PVC stick-up with a venthole.Top of PVC casing elev. = 591.18' Ground surface elev. = 588.33' Northing = 934,888.83' Easting = 2,049,113.74' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 585 580 575 570 565 560 555 550 CAVING> PIEZOMETER NO. PZ-157BSheet 1 of 1 3-23-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:0.64 PIEZOMETER NO. PZ-157B START: 3-22-21 588.33ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Firm, gray, and red, moist, fine tomedium sandy SILT with tracegravel - (RESIDUUM) Firm, gray and white, dry, gravely,fine to coarse SAND Dense, white, moist, silty, fine tocoarse SAND with trace clay Hard, white, moist, fine sandySILT with trace gravel PARTIALLY WEATHERED ROCKsampled as very dense, gray, dry,fine to coarse sandy andesite GRAVEL with trace clay PARTIALLY WEATHERED ROCKsampled as very dense, gray, dry,gravely, fine to coarse SAND Auger refusal at 18.5 feet below ground surface. No groundwater encountered at time of drilling, after 24 hours groundwater was encountered at 8.88 feet belowground surface. 225 5713 71221 151923 50/1" 50/1" Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 11.0 feet Filter pack, sand 11.0 to 18.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 13.0to 18.0 feet Pipe cap 0.33 feetTotal well depth, 18.33 feet SURFACE COMPLETION 2.44-foot PVC stick-up with a venthole.Top of PVC casing elev. = 589.70' Ground surface elev. = 587.26' Northing = 934,749.99' Easting = 2,049,051.36' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 585 580 575 570 565 560 555 550 CAVING> PIEZOMETER NO. PZ-158BSheet 1 of 1 3-23-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:8.88 PIEZOMETER NO. PZ-158B START: 3-22-21 587.26ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Firm, light brown/gray, slightlymoist, silty, fine to coarse SAND -(RESIDUUM) Very stiff, light brown, moist, fineto coarse sandy SILT with tracerhyolite gravel Very dense, gray, moist, silty, fine to coarse SAND with phaneriticrhyolite gravel and woody debris PARTIALLY WEATHERED ROCKsampled as very dense, gray, dry,silty, fine to coarse SAND withcompletly weathered rhyoliticgravel PARTIALLY WEATHERED ROCKsampled as very soft, very severeto complete weathering, light gray, aphanitic rhyolite GRAVEL Auger refusal at 13.5 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 2.60 feet belowground surface. 489 71215 151928 50/4" 50/1" Grout, 0 to 2.0 feet Bentonite seal, 2.0 to 6.0 feet Filter pack, sand 6.0 to 13.5 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 8.0to 13.0 feet Pipe cap 0.33 feetTotal well depth, 13.33 feet SURFACE COMPLETION 2.14-foot PVC stick-up with a venthole. Top of PVC casing elev. = 594.23' Ground surface elev. = 592.09' Northing = 934,725.92' Easting = 2,049,263.11' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 590 585 580 575 570 565 560 555 CAVING> PIEZOMETER NO. PZ-159BSheet 1 of 1 3-25-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:2.60 PIEZOMETER NO. PZ-159B START: 3-23-21 592.09ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES Firm, red/brown/yellow, moist,fine to medium sandy SILT -(RESIDUUM) Stiff, red/brown/yellow, moist, fineto medium sandy, silty CLAY Very stiff, red/gray, dry, fine tocoarse sandy SILT Hard, light brown/gray, dry, fine tomedium sandy SILT PARTIALLY WEATHERED ROCKsampled as very dense, lightbrown/gray, silty, fine to coarse SAND Auger refusal at 18.5 feet below ground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 13.38 feet belowground surface. Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 11.0 feet Filter pack, sand 11.0 to 18.5 feet 1-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 13.0to 18.0 feet Pipe cap 0.33 feetTotal well depth, 18.33 feet SURFACE COMPLETION 2.10-foot PVC stick-up with a venthole.Top of PVC casing elev. = 595.90' Ground surface elev. = 593.80' Northing = 934,739.30' Easting = 2,049,452.76' 234 UD-1359 71113 141721 50/2" 50/0" DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 590 585 580 575 570 565 560 555 CAVING> PIEZOMETER NO. PZ-160BSheet 1 of 1 3-25-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:13.38 PIEZOMETER NO. PZ-160B START: 3-23-21 593.80ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22SOILTYPE SAMPLES102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILS Stiff, light brown, moist, SILT withtrace sand - (RESIDUUM) Very stiff, light brown, moist, siltyclay with trace sand Very stiff, light brown and white, moist, clayey SILT with trace sand PARTIALLY WEATHERED ROCKsampled as very dense, lightbrown, moist, silty, fine to coarse SAND with trace gravel PARTIALLY WEATHERED ROCKsampled as very hard, brown,moist, fine to coarse sandy SILT with trace gravel PARTIALLY WEATHERED ROCKsampled as rhyolite gravel Auger refusal at 23.5 feet belowground surface. No groundwaterencountered at time of drilling,after 24 hours groundwater wasencountered at 10.96 feet belowground surface. 446 2713 41217 5813 50/6" 3550/2" 50/1" Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 14.0 feet Filter pack, sand 14.0 to 23.5 feet 2-inch diameter, 0.010-inch slotted Schedule 40 PVC well screen, 16.5to 21.5 feet Pipe cap 0.33 feet Total well depth, 21.83 feet SURFACE COMPLETION 2.62-foot PVC stick-up with a venthole.Top of PVC casing elev. = 594.71' Ground surface elev. = 592.09' Northing = 934,791.46' Easting = 2,049,689.05' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 590 585 580 575 570 565 560 555 CAVING> PIEZOMETER NO. PZ-161BSheet 1 of 1 3-8-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA J21-1003-81 AFTER 24 HOURS:10.96 PIEZOMETER NO. PZ-161B START: 3-3-21 592.09ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/2" PARTIALLY WEATHERED ROCKsampled as very dense, gray/red,dry, fine to coarse sandy rhyolitetuff GRAVEL - (RESIDUUM) Auger refusal at 5.5 feet below ground surface. No sample collected. Very soft to soft, very severe weathering, white and gray,pyroclastic, RHYOLITIC TUFF,with very close to close fractures,organic weathering, shallow tomoderately dipping, and Mgstaining. R-1 recovery = 82.4% RQD = 31% Very soft to soft, very severeweathering, white and gray,pyroclastic, RHYOLITIC TUFF,with very close to close fractures,organic weathering, shallow tosteep dipping, and Mg staining. R-2 recovery = 93% RQD = 58% Very soft to soft, very severe weathering, white and gray, pyroclastic, RHYOLITIC TUFF, with very close to close fractures, organic weathering, shallowdipping, and Mg staining. R-3 recovery = 28% RQD = 18.5% Boring terminated at 20.0 feetbelow ground surface. Nogroundwater encountered at timeof drilling, after 24 hoursgroundwater was encountered at8.82 feet below ground surface. 51150/5" 50/0" R-1 R-2 R-3 Grout, 0 to 4.0 feet Bentonite seal, 4.0 to 13.0 feet Filter pack, sand 13.0 to 20.0 feet 2-inch diameter, 0.010-inch slottedSchedule 40 PVC well screen, 14.6to 19.6 feet Pipe cap 0.33 feetTotal well depth, 19.93 feet SURFACE COMPLETION 2.45-foot PVC stick-up with a venthole. Top of PVC casing elev. = 597.03' Ground surface elev. = 594.58' Northing = 934,738.84' Easting = 2,049,925.61' DESCRIPTION LOCATION: DRILLER: DRILLING METHOD: 590 585 580 575 570 565 560 555 CAVING> PIEZOMETER NO. PZ-162CSheet 1 of 1 3-25-21 DEPTH TO - WATER> INITIAL: CLIENT: Dry PROJECT NO.: END:Republic Services Person County, North Carolina G. Eister, Bridger Drilling ELEVATION/DEPTH (FT) 5 10 15 20 25 30 35 PROJECT: CME 450 Track ATV with 8.25" O.D. HSA and NQ Core J21-1003-81 AFTER 24 HOURS:8.82 PIEZOMETER NO. PZ-162C START: 3-3-21 594.58ELEVATION: R. BlaisLOGGED BY: Upper Piedmont MSW Regional Landfill GEOT_WELL 1003-81.GPJ 4/12/22102 5 20 30 40 50 70 90 STANDARD PENETRATION RESULTSBLOWS/FOOT MONITOR WELL INSTALLATIONDETAILSSOILTYPE SAMPLES50/5" APPENDIX C Piezometer Installation Procedures APPENDIX C Piezometer Installation Procedures Groundwater piezometers were installed in the boreholes resulting from the drilling process. Approximate well locations are shown on the attached Piezometer/Boring Location Plan (Figure 2). The piezometer consists of 2-inch diameter PVC pipe (Schedule 40 with flush-threaded joints) inserted into 4.0 to 8.25-inch nominal diameter boreholes. The bottom 10 to 15-foot section of each piezometer was a manufactured screen with 0.010-inch slots. Washed sand backfill was placed around the outside of the pipe to at least 2 feet above the top of the well screen. A bentonite seal (minimum 2-foot thick) was installed on top of the sand backfill up to within 5 feet of the ground surface. The upper 5 feet was filled cement-bentonite grout mixture. A PVC cap was placed over the PVC well stickup on each piezometer. Piezometer construction records are attached in Appendix B. APPENDIX D Survey Data APPENDIX E Precipitation Data MONTHLY PRECIPITATION DATA - 1991 TO 2022 North Carolina - Division 3 Upper Piedmont MSW Landfill Person County, North Carolina BLE Project Number J21-1003-81 Year/Precipitation (inches) MONTH 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 31-Yr Monthly Avg. January 4.77 4.09 4.89 4.14 4.65 4.48 3.16 7.52 5.59 4.28 2.22 4.66 2.27 1.46 2.69 2.52 3.54 1.18 2.94 4.41 1.25 1.86 4.99 3.35 2.67 2.14 4 3.51 4.06 4.62 4.05 5.09 3.66 February 1.5 2.88 2.79 3.36 3.61 2.72 3.16 5.45 2.08 1.89 2.51 1.16 4.93 2.75 2.24 1.6 2.29 3 1.37 2.88 1.63 1.88 3.45 2.57 3.04 4.27 0.81 2.73 5.77 6.68 6.4 3.11 3.02 March 6.47 3.37 7.85 7.11 3.11 3.76 3.75 6.08 3.07 3.03 5.54 3.68 6.65 1.64 4.17 1.02 3.55 4.09 6 3.9 5.12 3.85 2.63 4.54 3.26 2.52 2.55 4.34 3.51 2.35 3.88 -4.08 April 3.35 3.66 5.04 1.99 0.9 3.36 5.68 4.65 4.45 5.15 2.17 1.32 6.22 2.8 2.23 3.53 3.79 5.49 2.28 1.48 3.21 2.79 3.97 4.91 3.47 2.8 7.56 5.1 4.63 5.06 1.95 -3.71 May 3.01 3.72 3.48 2.41 4.24 4.93 1.49 4.63 1.92 2.61 3.63 2.51 6.83 3.23 2.67 2.4 1.26 3.2 4.49 5.52 3.97 4.99 3.71 4.12 2.05 6.11 6.16 6.47 1.76 7.69 2.09 -3.78 June 2.54 4.77 2.2 3.15 10.43 2.93 4.17 2.7 2.56 4.87 4.17 2.21 6.13 4.41 3.18 8.41 3.65 3.01 5.66 2.57 2.74 2.61 7.67 2.52 4.8 4.94 5.61 3.3 7.75 4.95 4.09 -4.35 July 4.96 4.1 4.38 6.46 3.78 4.29 4.21 3.02 4.19 4.61 5.12 3.89 6.12 5.5 5.22 6.17 3.14 3.92 2.35 4 3.88 4.7 6.49 3.87 4.63 5.04 2.29 4.46 3.81 3.27 6.24 -4.46 August 3.66 4.76 2.38 4.24 3.96 6.07 1.95 2.89 3.59 4.95 3.15 5.2 6.38 7.25 2.87 3.56 1.2 6.26 3.09 4.2 3.43 5.24 3.89 4.45 3.14 4.09 4.3 7.71 3.87 7.52 4.29 -4.31 September 3.44 2.84 2.85 2.07 2.34 10.77 3.99 2.79 13.91 5.18 2.3 4.08 6.32 5.89 0.99 5.46 1.33 6.18 3.33 5.62 5.42 5.49 2.22 4.24 6.19 5.3 2.58 8.25 0.58 6.28 3.64 -4.58 October 1.49 3.97 2.4 2.5 7.92 3.41 2.82 1.47 2.82 0.04 0.98 7.93 2.6 2.26 3.6 4.16 5.59 1.35 2.46 3.37 3.59 2.39 1.85 3.15 4.92 4.94 3.06 5.96 5.14 4.35 2.46 -3.39 November 1.32 5.24 3.56 2.63 4.2 3.32 3.11 1.65 1.82 1.97 0.44 4.24 2.13 4.17 3.83 6.28 0.72 3.13 8.23 1.2 4.86 0.48 3.03 3.67 5.98 0.74 1.4 7.14 3.03 6.07 0.49 -3.23 December 3.39 2.78 4.16 1.06 1.6 4.14 2.88 4.86 2.08 1.46 2.31 4.79 3.55 2.56 4.81 2.41 3.98 4.03 6.6 2.5 2.64 3.01 5.47 3.27 7.01 1.83 1.59 5.84 3.73 5.36 1.61 -3.46 SEASON 31-Yr Seasonal Avg. Winter 12.74 10.34 15.53 14.61 11.37 10.96 10.07 19.05 10.74 9.2 10.27 9.5 13.85 5.85 9.1 5.14 9.38 8.27 10.31 11.19 8 7.59 11.07 10.46 8.97 8.93 7.36 10.58 13.34 13.65 14.33 -10.70 Spring 8.9 12.15 10.72 7.55 15.57 11.22 11.34 11.98 8.93 12.63 9.97 6.04 19.18 10.44 8.08 14.34 8.7 11.7 12.43 9.57 9.92 10.39 15.35 11.55 10.32 13.85 19.33 14.87 14.14 17.7 8.13 -11.84 Summer 12.06 11.7 9.61 12.77 10.08 21.13 10.15 8.7 21.69 14.74 10.57 13.17 18.82 18.64 9.08 15.19 5.67 16.36 8.77 13.82 12.73 15.43 12.6 12.56 13.96 14.43 9.17 20.42 8.26 17.07 14.17 -13.34 Fall 6.2 11.99 10.12 6.19 13.72 10.87 8.81 7.98 6.72 3.47 3.73 16.96 8.28 8.99 12.24 12.85 10.29 8.51 17.29 7.07 11.09 5.88 10.35 10.09 17.91 7.51 6.05 18.94 11.9 15.78 4.56 -10.08 Yearly Avg. Yearly Totals 39.90 46.18 45.98 41.12 50.74 54.18 40.37 47.71 48.08 40.04 34.54 45.67 60.13 43.92 38.50 47.52 34.04 44.84 48.80 41.65 41.74 39.29 49.37 44.66 51.16 44.72 41.91 64.81 47.64 64.20 41.19 8.20 46.00 Data Source: NOAA, public information - Updated May 2023 Months that water levels were collected from piezometers and wells at the site during the current hydrogeologic assessment. -6 -4 -2 0 2 4 6 8 Jan-02Jan-03Jan-04Jan-05Jan-06Jan-07Jan-08Jan-09Jan-10Jan-11Jan-12Jan-13Jan-14Jan-15Jan-16Jan-17Jan-18Jan-19Jan-20Jan-21Jan-22INDEX VALUE(-) Drought Conditions(+) Non-Drought ConditionsDATE PALMER DROUGHT SEVERITY INDEX North Carolina Division 3 Upper Piedmont MSW Landfill Person Co., North Carolina BLE Project Number J21-1003-81 APPENDIX F Slug Test Procedures and Results APPENDIX F Slug Test Procedures and Results Slug tests were performed in the field to estimate the average hydraulic conductivity of the upper formation material. Hydraulic conductivity is a constant of proportionality relating to the ease with which a fluid passes through a porous medium. These data were used to estimate the groundwater flow velocities of groundwater beneath the site. The field procedure was as follows: • Measure the static groundwater elevation in the well to be tested. • Affect an instantaneous change to the static water level in the well by removing a known volume of water. • Measure the rate at which shown on the attached sheets the water level recovers to its original level. The resulting slug test data (time versus water level) was reduced and hydraulic conductivity values were calculated using the Bouwer and Rice (1976) Method for partially-penetrating wells in an unconfined aquifer. S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\From Prior Reports\GW-6.slg Page 1 Bouwer and Rice GraphFalling Head Slug Test 1/8/04 Upper Piedmont Regional MSW Landfill - Person County, North Carolina Project Number: J03-1003-41 for Republic Services, LLC Analysis by BLE GW-6 Ho is 3.88 feet at 10.2 Seconds 0 1 Adjusted Time (Hours)Head Ratio (Ht/Ho)1.e-002 0.1 1. Bouwer and Rice parameter C = 3.74 ln(Re/Rw) = 3.506616e+000 Analysis starts at time 49.8 Seconds Analysis ends at time 120 minutes 43 Measurements analyzed from 6 to 48 Hydraulic Conductivity = 4.28e-007 cm/sec Transmissivity = 1.29e-005 ft2/min S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\From Prior Reports\GW-6.slg Page 1 Falling Head Slug Test Site Name:Upper Piedmont Regional MSW Landfill - Location:Person County, North Carolina Test Date:1/8/04 Client:Republic Services, LLC Project Number:J03-1003-41 Import File:C:\MSP Files\Upper Piedmont LF NC\100341\UPLF GW-6 slug data.txt Well Label:GW-6 Aquifer Thickness:15.3 feet Screen Length:15. feet Casing Radius:8.33e-002 feet Effective Radius:0.167 feet Static Water Level:0. feet Water Table to Screen Bottom:15.3 feet Anisotropy Ratio:1. Time Adjustment:10.2 Seconds Test starts with trial 0 There are 48 time and drawdown measurements Maximum head is 3.88 feet Minimum head is 0. feet Trial Time Adjusted Time Drawdown Head Head Ratio (Seconds)(Seconds)(feet)(feet) 1 10.2 0.3.88 3.88 1. 2 15.4.8 3.85 3.85 0.992 3 19.8 9.6 3.84 3.84 0.99 4 30.19.8 3.83 3.83 0.987 5 40.2 30.3.82 3.82 0.985 6 49.8 39.6 3.82 3.82 0.985 7 60.49.8 3.81 3.81 0.982 8 70.2 60.3.81 3.81 0.982 9 79.8 69.6 3.8 3.8 0.979 10 90.79.8 3.8 3.8 0.979 11 100 90.3.79 3.79 0.977 12 110 99.6 3.79 3.79 0.977 13 120 110 3.79 3.79 0.977 14 150 140 3.78 3.78 0.974 15 180 170 3.78 3.78 0.974 16 210 200 3.77 3.77 0.972 17 240 230 3.76 3.76 0.969 18 270 260 3.76 3.76 0.969 19 300 290 3.75 3.75 0.966 20 330 320 3.74 3.74 0.964 21 360 350 3.73 3.73 0.961 22 390 380 3.73 3.73 0.961 23 420 410 3.73 3.73 0.961 24 450 440 3.73 3.73 0.961 25 480 470 3.72 3.72 0.959 26 540 530 3.72 3.72 0.959 27 600 590 3.71 3.71 0.956 28 660 650 3.71 3.71 0.956 29 720 710 3.7 3.7 0.954 30 780 770 3.7 3.7 0.954 31 840 830 3.69 3.69 0.951 32 900 890 3.68 3.68 0.948 33 960 950 3.67 3.67 0.946 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\From Prior Reports\GW-6.slg Page 2 34 1.02e+003 1.01e+003 3.67 3.67 0.946 35 1.08e+003 1.07e+003 3.66 3.66 0.943 36 1.14e+003 1.13e+003 3.66 3.66 0.943 37 1.2e+003 1.19e+003 3.66 3.66 0.943 38 1.5e+003 1.49e+003 3.63 3.63 0.936 39 1.8e+003 1.79e+003 3.61 3.61 0.93 40 2.4e+003 2.39e+003 3.57 3.57 0.92 41 3.e+003 2.99e+003 3.54 3.54 0.912 42 3.6e+003 3.59e+003 3.5 3.5 0.902 43 4.2e+003 4.19e+003 3.48 3.48 0.897 44 4.8e+003 4.79e+003 3.46 3.46 0.892 45 5.4e+003 5.39e+003 3.43 3.43 0.884 46 6.e+003 5.99e+003 3.42 3.42 0.881 47 6.6e+003 6.59e+003 3.4 3.4 0.876 48 7.2e+003 7.19e+003 3.38 3.38 0.871 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\From Prior Reports\PZ-20ab.slg Page 1 Bouwer and Rice GraphUpper Piedmont Regional MSWLF Person County, NC 4/23/99 Project Number: J99-1003-16 for Republic Services, LLC Analysis by BLE PZ-20ab Ho is 3.5 feet at 10. Seconds 0 1 2 3 Adjusted Time (Hours)Head Ratio (Ht/Ho)1.e-002 0.1 1. Bouwer and Rice parameter C = 1.91 ln(Re/Rw) = 2.487066e+000 Analysis starts at time 660 Seconds Analysis ends at time 110 minutes 17 Measurements analyzed from 31 to 47 Hydraulic Conductivity = 6.74e-006 cm/sec Transmissivity = 1.25e-004 ft2/min S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\From Prior Reports\PZ-20ab.slg Page 1 Site Name:Upper Piedmont Regional MSWLF Location:Person County, NC Test Date:4/23/99 Client:Republic Services, LLC Project Number:J99-1003-16 Well Label:PZ-20ab Aquifer Thickness:9.42 feet Screen Length:9.42 feet Casing Radius:8.33e-002 feet Effective Radius:0.344 feet Static Water Level:13.1 feet Water Table to Screen Bottom:9.42 feet Anisotropy Ratio:1. Time Adjustment:10. Seconds Test starts with trial 1 There are 48 time and drawdown measurements Maximum head is 3.5 feet Minimum head is 0. feet Trial Time Adjusted Time Drawdown Head Head Ratio (Seconds)(Seconds)(feet)(feet) 1 0.-10.13.1 2.e-002 5.71e-003 2 10.0.9.6 3.5 1. 3 15.5.9.78 3.32 0.949 4 20.10.9.85 3.25 0.929 5 30.20.10.1 3.05 0.871 6 40.30.10.2 2.88 0.823 7 50.40.10.3 2.76 0.789 8 60.50.10.5 2.6 0.743 9 70.60.10.6 2.48 0.709 10 80.70.10.7 2.38 0.68 11 90.80.10.8 2.3 0.657 12 100 90.10.9 2.2 0.629 13 110 100.10.9 2.16 0.617 14 120 110 11.2.1 0.6 15 150 140 11.2 1.95 0.557 16 180 170 11.3 1.83 0.523 17 210 200 11.4 1.73 0.494 18 240 230 11.4 1.65 0.471 19 270 260 11.5 1.59 0.454 20 300 290 11.6 1.53 0.437 21 330 320 11.6 1.49 0.426 22 360 350 11.7 1.44 0.411 23 390 380 11.7 1.4 0.4 24 420 410 11.7 1.38 0.394 25 450 440 11.8 1.34 0.383 26 480 470 11.8 1.3 0.371 27 510 500 11.8 1.29 0.369 28 540 530 11.8 1.27 0.363 29 570 560 11.9 1.24 0.354 30 600 590 11.9 1.22 0.349 31 660 650 11.9 1.17 0.334 32 720 710 12.1.13 0.323 33 780 770 12.1.1 0.314 34 840 830 12.1.07 0.306 35 900 890 12.1 1.05 0.3 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\From Prior Reports\PZ-20ab.slg Page 2 36 960 950 12.1 1.03 0.294 37 1.02e+003 1.01e+003 12.1 1.01 0.289 38 1.08e+003 1.07e+003 12.1 0.99 0.283 39 1.14e+003 1.13e+003 12.1 0.98 0.28 40 1.2e+003 1.19e+003 12.1 0.96 0.274 41 1.5e+003 1.49e+003 12.2 0.91 0.26 42 1.8e+003 1.79e+003 12.3 0.84 0.24 43 2.1e+003 2.09e+003 12.3 0.8 0.229 44 2.4e+003 2.39e+003 12.4 0.75 0.214 45 3.e+003 2.99e+003 12.4 0.66 0.189 46 3.6e+003 3.59e+003 12.5 0.59 0.169 47 6.6e+003 6.59e+003 12.7 0.39 0.111 48 1.2e+004 1.2e+004 12.9 0.24 6.86e-002 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\From Prior Reports\PZ-22c.slg Page 1 Bouwer and Rice GraphUpper Piedmont Regional MSWLF Person County, NC 4/23/99 Project Number: J99-1003-16 for Republic Services, LLC Analysis by BLE PZ-22c Ho is 1.03 feet at 5. Seconds 0 1 Adjusted Time (Hours)Head Ratio (Ht/Ho)1.e-002 0.1 1. Bouwer and Rice parameter C = 5.89 ln(Re/Rw) = 3.966434e+000 Analysis starts at time 90. Seconds Analysis ends at time 40. minutes 33 Measurements analyzed from 10 to 42 Hydraulic Conductivity = 2.2e-006 cm/sec Transmissivity = 8.74e-005 ft2/min S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\From Prior Reports\PZ-22c.slg Page 1 Site Name:Upper Piedmont Regional MSWLF Location:Person County, NC Test Date:4/23/99 Client:Republic Services, LLC Project Number:J99-1003-16 Well Label:PZ-22c Aquifer Thickness:20.2 feet Screen Length:20.2 feet Casing Radius:0.124 feet Effective Radius:0.124 feet Static Water Level:14.5 feet Water Table to Screen Bottom:20.2 feet Anisotropy Ratio:1. Time Adjustment:5. Seconds Test starts with trial 1 There are 43 time and drawdown measurements Maximum head is 1.03 feet Minimum head is -1.e-002 feet Trial Time Adjusted Time Drawdown Head Head Ratio (Seconds)(Seconds)(feet)(feet) 1 0.-5.14.5 -1.e-002 -9.71e-003 2 5.0.13.5 1.03 1. 3 20.15.13.5 1.02 0.99 4 30.25.13.5 1.01 0.981 5 40.35.13.5 1.01 0.981 6 50.45.13.5 1.01 0.981 7 60.55.13.5 1.01 0.981 8 70.65.13.5 1.01 0.981 9 80.75.13.5 1.01 0.981 10 90.85.13.5 1.0.971 11 100 95.13.5 1.0.971 12 110 105 13.5 1.0.971 13 120 115 13.5 1.0.971 14 150 145 13.5 1.0.971 15 180 175 13.5 1.0.971 16 210 205 13.5 1.0.971 17 240 235 13.5 1.0.971 18 270 265 13.5 1.0.971 19 300 295 13.5 1.0.971 20 330 325 13.5 1.0.971 21 360 355 13.5 1.0.971 22 390 385 13.5 1.0.971 23 420 415 13.5 1.0.971 24 450 445 13.5 1.0.971 25 480 475 13.5 1.0.971 26 510 505 13.5 1.0.971 27 540 535 13.5 0.99 0.961 28 570 565 13.5 0.99 0.961 29 600 595 13.5 0.99 0.961 30 660 655 13.5 0.99 0.961 31 720 715 13.5 0.99 0.961 32 780 775 13.5 0.99 0.961 33 840 835 13.5 0.99 0.961 34 900 895 13.5 0.98 0.951 35 960 955 13.5 0.98 0.951 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\From Prior Reports\PZ-22c.slg Page 2 36 1.02e+003 1.02e+003 13.5 0.98 0.951 37 1.08e+003 1.08e+003 13.5 0.97 0.942 38 1.14e+003 1.14e+003 13.5 0.97 0.942 39 1.2e+003 1.2e+003 13.5 0.96 0.932 40 1.5e+003 1.5e+003 13.6 0.94 0.913 41 1.8e+003 1.8e+003 13.6 0.92 0.893 42 2.4e+003 2.4e+003 13.6 0.89 0.864 43 4.5e+003 4.5e+003 13.7 0.81 0.786 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ132BFH.slg Page 1 Bouwer and Rice GraphFalling Head Slug Test October 28, 2021 Upper Piedmont Regional MSW Landfill Rougemont, NC Project Number: 1003-81 for Republic Services of North Carolina, LLC. Analysis by BLE PZ-132B Ho is 3.55 feet at 11. Seconds 0 Adjusted Time (Hours)Head Ratio (Ht/Ho)1.e-002 0.1 1. Bouwer and Rice parameter C = 1.97 ln(Re/Rw) = 2.659335e+000 Analysis starts at time 19. Seconds Analysis ends at time 47. minutes 133 Measurements analyzed from 10 to 142 Hydraulic Conductivity = 3.31e-005 cm/sec Transmissivity = 7.93e-004 ft2/min S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ132BFH.slg Page 1 Falling Head Slug Test Site Name:Upper Piedmont Regional MSW Landfill Location:Rougemont, NC Test Date:October 28, 2021 Client:Republic Services of North Carolina, LLC. Project Number:1003-81 Import File:S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\ Well Label:PZ-132B Aquifer Thickness:12.2 feet Screen Length:10. feet Casing Radius:8.33e-002 feet Effective Radius:0.344 feet Static Water Level:0. feet Water Table to Screen Bottom:12.2 feet Anisotropy Ratio:2. Time Adjustment:11. Seconds Test starts with trial 1 There are 155 time and drawdown measurements Maximum head is 3.55 feet Minimum head is 0. feet Trial Time Adjusted Time Drawdown Head Head Ratio (Seconds)(Seconds)(feet)(feet) 1 10.-0.96 3.54 3.54 0.996 2 11.0.3.55 3.55 1. 3 12.1.02 3.54 3.54 0.998 4 13.2.04 3.54 3.54 0.996 5 14.3.3.53 3.53 0.994 6 15.4.02 3.52 3.52 0.991 7 16.5.04 3.52 3.52 0.991 8 17.6.3.51 3.51 0.989 9 18.7.02 3.5 3.5 0.987 10 19.8.04 3.5 3.5 0.987 11 20.9.3.5 3.5 0.987 12 21.10.3.5 3.5 0.985 13 22.11.3.5 3.5 0.985 14 23.12.3.48 3.48 0.98 15 24.13.3.48 3.48 0.98 16 25.14.3.47 3.47 0.978 17 26.15.3.47 3.47 0.978 18 27.16.3.46 3.46 0.976 19 28.17.3.46 3.46 0.976 20 29.18.3.46 3.46 0.976 21 30.19.3.46 3.46 0.974 22 31.20.3.46 3.46 0.974 23 32.21.3.45 3.45 0.971 24 33.22.3.45 3.45 0.971 25 34.23.3.44 3.44 0.969 26 35.24.3.43 3.43 0.967 27 36.25.3.43 3.43 0.967 28 37.26.3.43 3.43 0.967 29 38.27.3.43 3.43 0.965 30 39.28.3.42 3.42 0.962 31 40.29.3.42 3.42 0.963 32 41.30.3.42 3.42 0.963 33 42.31.3.41 3.41 0.96 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ132BFH.slg Page 2 34 43.32.3.41 3.41 0.96 35 44.33.3.4 3.4 0.958 36 45.34.3.4 3.4 0.958 37 46.35.3.4 3.4 0.958 38 47.36.3.4 3.4 0.958 39 48.37.3.38 3.38 0.953 40 49.38.3.39 3.39 0.956 41 50.39.3.38 3.38 0.953 42 51.40.3.38 3.38 0.953 43 52.41.3.38 3.38 0.951 44 53.42.3.38 3.38 0.951 45 54.43.3.37 3.37 0.949 46 55.44.3.36 3.36 0.947 47 56.45.3.36 3.36 0.947 48 57.46.3.36 3.36 0.947 49 58.47.3.36 3.36 0.947 50 59.48.3.35 3.35 0.945 51 60.49.3.35 3.35 0.942 52 70.59.3.31 3.31 0.934 53 80.69.3.3 3.3 0.929 54 90.79.3.27 3.27 0.92 55 100 89.3.23 3.23 0.909 56 110 99.3.21 3.21 0.903 57 120 109 3.18 3.18 0.897 58 130 119 3.15 3.15 0.888 59 140 129 3.12 3.12 0.879 60 150 139 3.1 3.1 0.873 61 160 149 3.08 3.08 0.866 62 170 159 3.04 3.04 0.857 63 180 169 3.01 3.01 0.848 64 190 179 2.99 2.99 0.841 65 200 189 2.96 2.96 0.834 66 210 199 2.93 2.93 0.825 67 220 209 2.91 2.91 0.819 68 230 219 2.88 2.88 0.81 69 240 229 2.85 2.85 0.803 70 250 239 2.83 2.83 0.797 71 260 249 2.8 2.8 0.789 72 270 259 2.78 2.78 0.782 73 280 269 2.76 2.76 0.778 74 290 279 2.73 2.73 0.769 75 300 289 2.71 2.71 0.762 76 310 299 2.68 2.68 0.756 77 320 309 2.65 2.65 0.747 78 330 319 2.64 2.64 0.745 79 340 329 2.61 2.61 0.734 80 350 339 2.59 2.59 0.729 81 360 349 2.57 2.57 0.723 82 370 359 2.54 2.54 0.716 83 380 369 2.51 2.51 0.707 84 390 379 2.49 2.49 0.701 85 400 389 2.46 2.46 0.694 86 410 399 2.45 2.45 0.69 87 420 409 2.43 2.43 0.685 88 430 419 2.41 2.41 0.679 89 440 429 2.38 2.38 0.67 90 450 439 2.36 2.36 0.663 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ132BFH.slg Page 3 91 460 449 2.34 2.34 0.659 92 470 459 2.31 2.31 0.65 93 480 469 2.29 2.29 0.646 94 490 479 2.27 2.27 0.639 95 500 489 2.25 2.25 0.635 96 510 499 2.22 2.22 0.626 97 520 509 2.21 2.21 0.622 98 530 519 2.18 2.18 0.615 99 540 529 2.17 2.17 0.61 100 550 539 2.14 2.14 0.604 101 560 549 2.13 2.13 0.599 102 570 559 2.1 2.1 0.593 103 580 569 2.09 2.09 0.588 104 590 579 2.06 2.06 0.579 105 600 589 2.03 2.03 0.573 106 660 649 1.92 1.92 0.54 107 720 709 1.81 1.81 0.509 108 780 769 1.69 1.69 0.476 109 840 829 1.58 1.58 0.445 110 900 889 1.49 1.49 0.418 111 960 949 1.4 1.4 0.393 112 1.02e+003 1.01e+003 1.31 1.31 0.369 113 1.08e+003 1.07e+003 1.23 1.23 0.345 114 1.14e+003 1.13e+003 1.14 1.14 0.321 115 1.2e+003 1.19e+003 1.07 1.07 0.301 116 1.26e+003 1.25e+003 0.983 0.983 0.277 117 1.32e+003 1.31e+003 0.912 0.912 0.257 118 1.38e+003 1.37e+003 0.85 0.85 0.239 119 1.44e+003 1.43e+003 0.787 0.787 0.222 120 1.5e+003 1.49e+003 0.724 0.724 0.204 121 1.56e+003 1.55e+003 0.669 0.669 0.188 122 1.62e+003 1.61e+003 0.614 0.614 0.173 123 1.68e+003 1.67e+003 0.567 0.567 0.16 124 1.74e+003 1.73e+003 0.515 0.515 0.145 125 1.8e+003 1.79e+003 0.478 0.478 0.135 126 1.86e+003 1.85e+003 0.44 0.44 0.124 127 1.92e+003 1.91e+003 0.393 0.393 0.111 128 1.98e+003 1.97e+003 0.362 0.362 0.102 129 2.04e+003 2.03e+003 0.331 0.331 9.32e-002 130 2.1e+003 2.09e+003 0.3 0.3 8.45e-002 131 2.16e+003 2.15e+003 0.275 0.275 7.74e-002 132 2.22e+003 2.21e+003 0.252 0.252 7.1e-002 133 2.28e+003 2.27e+003 0.228 0.228 6.42e-002 134 2.34e+003 2.33e+003 0.212 0.212 5.97e-002 135 2.4e+003 2.39e+003 0.186 0.186 5.24e-002 136 2.46e+003 2.45e+003 0.176 0.176 4.96e-002 137 2.52e+003 2.51e+003 0.164 0.164 4.62e-002 138 2.58e+003 2.57e+003 0.149 0.149 4.2e-002 139 2.64e+003 2.63e+003 0.141 0.141 3.97e-002 140 2.7e+003 2.69e+003 0.133 0.133 3.75e-002 141 2.76e+003 2.75e+003 0.126 0.126 3.55e-002 142 2.82e+003 2.81e+003 0.118 0.118 3.32e-002 143 2.88e+003 2.87e+003 0.111 0.111 3.13e-002 144 2.94e+003 2.93e+003 0.111 0.111 3.13e-002 145 3.e+003 2.99e+003 0.102 0.102 2.87e-002 146 3.06e+003 3.05e+003 9.4e-002 9.4e-002 2.65e-002 147 3.12e+003 3.11e+003 9.1e-002 9.1e-002 2.56e-002 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ132BFH.slg Page 4 148 3.18e+003 3.17e+003 8.3e-002 8.3e-002 2.34e-002 149 3.24e+003 3.23e+003 8.5e-002 8.5e-002 2.39e-002 150 3.3e+003 3.29e+003 8.5e-002 8.5e-002 2.39e-002 151 3.36e+003 3.35e+003 8.6e-002 8.6e-002 2.42e-002 152 3.42e+003 3.41e+003 7.8e-002 7.8e-002 2.2e-002 153 3.48e+003 3.47e+003 7.3e-002 7.3e-002 2.06e-002 154 3.54e+003 3.53e+003 8.2e-002 8.2e-002 2.31e-002 155 3.6e+003 3.59e+003 7.3e-002 7.3e-002 2.06e-002 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 1 Bouwer and Rice GraphFalling Head Slug Test February 16, 2022 Upper Piedmont Regional MSW Landfill Rougemont, NC Project Number: 1003-81 for Republic Services of North Carolina, LLC. Analysis by BLE PZ-139C Ho is 5.03 feet at 7.02 Seconds 0 1 2 3 4 5 6 7 8 9 10 11 Adjusted Time (Hours)Head Ratio (Ht/Ho)1.e-002 0.1 1. Bouwer and Rice parameter C = 2.25 ln(Re/Rw) = 3.194944e+000 Analysis starts at time 48. Seconds Analysis ends at time 664 minutes 721 Measurements analyzed from 41 to 761 Hydraulic Conductivity = 2.78e-007 cm/sec Transmissivity = 4.96e-006 ft2/min S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 1 Falling Head Slug Test Site Name:Upper Piedmont Regional MSW Landfill Location:Rougemont, NC Test Date:February 16, 2022 Client:Republic Services of North Carolina, LLC. Project Number:1003-81 Import File:S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\ Well Label:PZ-139C Aquifer Thickness:9.07 feet Screen Length:5. feet Casing Radius:8.33e-002 feet Effective Radius:0.125 feet Static Water Level:0. feet Water Table to Screen Bottom:9.07 feet Anisotropy Ratio:2. Time Adjustment:7.02 Seconds Test starts with trial 0 There are 761 time and drawdown measurements Maximum head is 5.03 feet Minimum head is 0. feet Trial Time Adjusted Time Drawdown Head Head Ratio (Seconds)(Seconds)(feet)(feet) 1 7.02 0.5.03 5.03 1. 2 7.98 0.96 4.45 4.45 0.884 3 9.1.98 4.58 4.58 0.911 4 11.3.96 3.53 3.53 0.702 5 12.4.98 3.52 3.52 0.7 6 13.6.3.51 3.51 0.698 7 14.6.96 3.5 3.5 0.697 8 15.7.98 3.48 3.48 0.693 9 16.9.3.49 3.49 0.694 10 17.9.96 3.48 3.48 0.693 11 18.11.3.48 3.48 0.692 12 19.12.3.48 3.48 0.692 13 20.13.3.48 3.48 0.692 14 21.14.3.47 3.47 0.69 15 22.15.3.47 3.47 0.69 16 23.16.3.47 3.47 0.69 17 24.17.3.45 3.45 0.687 18 25.18.3.45 3.45 0.687 19 26.19.3.45 3.45 0.687 20 27.20.3.45 3.45 0.687 21 28.21.3.45 3.45 0.687 22 29.22.3.45 3.45 0.687 23 30.23.3.45 3.45 0.687 24 31.24.3.45 3.45 0.686 25 32.25.3.45 3.45 0.686 26 33.26.3.45 3.45 0.686 27 34.27.3.44 3.44 0.684 28 35.28.3.45 3.45 0.686 29 36.29.3.45 3.45 0.686 30 37.30.3.44 3.44 0.684 31 38.31.3.44 3.44 0.684 32 39.32.3.44 3.44 0.684 33 40.33.3.44 3.44 0.684 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 2 34 41.34.3.44 3.44 0.684 35 42.35.3.43 3.43 0.682 36 43.36.3.44 3.44 0.684 37 44.37.3.44 3.44 0.684 38 45.38.3.43 3.43 0.682 39 46.39.3.44 3.44 0.684 40 47.40.3.42 3.42 0.681 41 48.41.3.43 3.43 0.682 42 49.42.3.43 3.43 0.682 43 50.43.3.43 3.43 0.682 44 51.44.3.43 3.43 0.682 45 52.45.3.44 3.44 0.684 46 53.46.3.43 3.43 0.682 47 54.47.3.43 3.43 0.682 48 55.48.3.43 3.43 0.682 49 56.49.3.43 3.43 0.682 50 57.50.3.43 3.43 0.682 51 58.51.3.42 3.42 0.681 52 59.52.3.43 3.43 0.682 53 60.53.3.43 3.43 0.682 54 70.63.3.42 3.42 0.681 55 80.73.3.42 3.42 0.68 56 90.83.3.42 3.42 0.681 57 100 93.3.42 3.42 0.681 58 110 103 3.42 3.42 0.681 59 120 113 3.42 3.42 0.681 60 130 123 3.42 3.42 0.681 61 140 133 3.42 3.42 0.681 62 150 143 3.42 3.42 0.68 63 160 153 3.42 3.42 0.68 64 170 163 3.42 3.42 0.68 65 180 173 3.42 3.42 0.68 66 190 183 3.42 3.42 0.68 67 200 193 3.42 3.42 0.68 68 210 203 3.42 3.42 0.68 69 220 213 3.42 3.42 0.68 70 230 223 3.42 3.42 0.68 71 240 233 3.42 3.42 0.68 72 250 243 3.43 3.43 0.682 73 260 253 3.42 3.42 0.68 74 270 263 3.42 3.42 0.68 75 280 273 3.42 3.42 0.68 76 290 283 3.42 3.42 0.68 77 300 293 3.42 3.42 0.68 78 310 303 3.41 3.41 0.679 79 320 313 3.42 3.42 0.68 80 330 323 3.42 3.42 0.68 81 340 333 3.42 3.42 0.68 82 350 343 3.41 3.41 0.679 83 360 353 3.42 3.42 0.68 84 370 363 3.42 3.42 0.68 85 380 373 3.42 3.42 0.68 86 390 383 3.41 3.41 0.679 87 400 393 3.41 3.41 0.679 88 410 403 3.41 3.41 0.679 89 420 413 3.41 3.41 0.679 90 430 423 3.41 3.41 0.679 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 3 91 440 433 3.41 3.41 0.679 92 450 443 3.41 3.41 0.679 93 460 453 3.41 3.41 0.679 94 470 463 3.41 3.41 0.679 95 480 473 3.41 3.41 0.679 96 490 483 3.41 3.41 0.679 97 500 493 3.41 3.41 0.679 98 510 503 3.4 3.4 0.677 99 520 513 3.41 3.41 0.679 100 530 523 3.41 3.41 0.679 101 540 533 3.41 3.41 0.679 102 550 543 3.4 3.4 0.677 103 560 553 3.41 3.41 0.679 104 570 563 3.4 3.4 0.677 105 580 573 3.41 3.41 0.679 106 590 583 3.4 3.4 0.677 107 600 593 3.4 3.4 0.677 108 660 653 3.4 3.4 0.677 109 720 713 3.4 3.4 0.677 110 780 773 3.4 3.4 0.677 111 840 833 3.4 3.4 0.677 112 900 893 3.4 3.4 0.676 113 960 953 3.4 3.4 0.676 114 1.02e+003 1.01e+003 3.4 3.4 0.676 115 1.08e+003 1.07e+003 3.4 3.4 0.676 116 1.14e+003 1.13e+003 3.4 3.4 0.676 117 1.2e+003 1.19e+003 3.39 3.39 0.674 118 1.26e+003 1.25e+003 3.39 3.39 0.674 119 1.32e+003 1.31e+003 3.4 3.4 0.676 120 1.38e+003 1.37e+003 3.4 3.4 0.676 121 1.44e+003 1.43e+003 3.4 3.4 0.676 122 1.5e+003 1.49e+003 3.39 3.39 0.674 123 1.56e+003 1.55e+003 3.39 3.39 0.674 124 1.62e+003 1.61e+003 3.39 3.39 0.674 125 1.68e+003 1.67e+003 3.39 3.39 0.674 126 1.74e+003 1.73e+003 3.39 3.39 0.674 127 1.8e+003 1.79e+003 3.39 3.39 0.674 128 1.86e+003 1.85e+003 3.39 3.39 0.674 129 1.92e+003 1.91e+003 3.39 3.39 0.674 130 1.98e+003 1.97e+003 3.39 3.39 0.674 131 2.04e+003 2.03e+003 3.38 3.38 0.673 132 2.1e+003 2.09e+003 3.38 3.38 0.673 133 2.16e+003 2.15e+003 3.38 3.38 0.673 134 2.22e+003 2.21e+003 3.37 3.37 0.671 135 2.28e+003 2.27e+003 3.37 3.37 0.67 136 2.34e+003 2.33e+003 3.37 3.37 0.67 137 2.4e+003 2.39e+003 3.37 3.37 0.67 138 2.46e+003 2.45e+003 3.36 3.36 0.668 139 2.52e+003 2.51e+003 3.36 3.36 0.668 140 2.58e+003 2.57e+003 3.36 3.36 0.668 141 2.64e+003 2.63e+003 3.35 3.35 0.667 142 2.7e+003 2.69e+003 3.34 3.34 0.665 143 2.76e+003 2.75e+003 3.34 3.34 0.665 144 2.82e+003 2.81e+003 3.33 3.33 0.663 145 2.88e+003 2.87e+003 3.34 3.34 0.665 146 2.94e+003 2.93e+003 3.33 3.33 0.663 147 3.e+003 2.99e+003 3.33 3.33 0.662 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 4 148 3.06e+003 3.05e+003 3.33 3.33 0.662 149 3.12e+003 3.11e+003 3.32 3.32 0.661 150 3.18e+003 3.17e+003 3.33 3.33 0.662 151 3.24e+003 3.23e+003 3.32 3.32 0.66 152 3.3e+003 3.29e+003 3.32 3.32 0.66 153 3.36e+003 3.35e+003 3.31 3.31 0.659 154 3.42e+003 3.41e+003 3.31 3.31 0.659 155 3.48e+003 3.47e+003 3.3 3.3 0.657 156 3.54e+003 3.53e+003 3.3 3.3 0.657 157 3.6e+003 3.59e+003 3.3 3.3 0.657 158 3.66e+003 3.65e+003 3.3 3.3 0.657 159 3.72e+003 3.71e+003 3.29 3.29 0.656 160 3.78e+003 3.77e+003 3.29 3.29 0.654 161 3.84e+003 3.83e+003 3.28 3.28 0.652 162 3.9e+003 3.89e+003 3.29 3.29 0.654 163 3.96e+003 3.95e+003 3.29 3.29 0.654 164 4.02e+003 4.01e+003 3.28 3.28 0.652 165 4.08e+003 4.07e+003 3.28 3.28 0.652 166 4.14e+003 4.13e+003 3.28 3.28 0.652 167 4.2e+003 4.19e+003 3.27 3.27 0.651 168 4.26e+003 4.25e+003 3.27 3.27 0.651 169 4.32e+003 4.31e+003 3.26 3.26 0.649 170 4.38e+003 4.37e+003 3.26 3.26 0.649 171 4.44e+003 4.43e+003 3.26 3.26 0.649 172 4.5e+003 4.49e+003 3.26 3.26 0.649 173 4.56e+003 4.55e+003 3.25 3.25 0.646 174 4.62e+003 4.61e+003 3.25 3.25 0.646 175 4.68e+003 4.67e+003 3.25 3.25 0.646 176 4.74e+003 4.73e+003 3.24 3.24 0.645 177 4.8e+003 4.79e+003 3.25 3.25 0.646 178 4.86e+003 4.85e+003 3.24 3.24 0.645 179 4.92e+003 4.91e+003 3.24 3.24 0.645 180 4.98e+003 4.97e+003 3.24 3.24 0.645 181 5.04e+003 5.03e+003 3.23 3.23 0.643 182 5.1e+003 5.09e+003 3.23 3.23 0.643 183 5.16e+003 5.15e+003 3.22 3.22 0.641 184 5.22e+003 5.21e+003 3.23 3.23 0.643 185 5.28e+003 5.27e+003 3.22 3.22 0.641 186 5.34e+003 5.33e+003 3.22 3.22 0.641 187 5.4e+003 5.39e+003 3.22 3.22 0.641 188 5.46e+003 5.45e+003 3.22 3.22 0.64 189 5.52e+003 5.51e+003 3.21 3.21 0.638 190 5.58e+003 5.57e+003 3.22 3.22 0.64 191 5.64e+003 5.63e+003 3.21 3.21 0.638 192 5.7e+003 5.69e+003 3.21 3.21 0.638 193 5.76e+003 5.75e+003 3.21 3.21 0.638 194 5.82e+003 5.81e+003 3.21 3.21 0.638 195 5.88e+003 5.87e+003 3.21 3.21 0.638 196 5.94e+003 5.93e+003 3.21 3.21 0.638 197 6.e+003 5.99e+003 3.2 3.2 0.637 198 6.06e+003 6.05e+003 3.2 3.2 0.637 199 6.12e+003 6.11e+003 3.19 3.19 0.635 200 6.18e+003 6.17e+003 3.19 3.19 0.635 201 6.24e+003 6.23e+003 3.19 3.19 0.635 202 6.3e+003 6.29e+003 3.19 3.19 0.634 203 6.36e+003 6.35e+003 3.19 3.19 0.634 204 6.42e+003 6.41e+003 3.19 3.19 0.634 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 5 205 6.48e+003 6.47e+003 3.19 3.19 0.634 206 6.54e+003 6.53e+003 3.18 3.18 0.632 207 6.6e+003 6.59e+003 3.18 3.18 0.632 208 6.66e+003 6.65e+003 3.18 3.18 0.632 209 6.72e+003 6.71e+003 3.18 3.18 0.632 210 6.78e+003 6.77e+003 3.17 3.17 0.631 211 6.84e+003 6.83e+003 3.16 3.16 0.629 212 6.9e+003 6.89e+003 3.17 3.17 0.631 213 6.96e+003 6.95e+003 3.17 3.17 0.631 214 7.02e+003 7.01e+003 3.16 3.16 0.629 215 7.08e+003 7.07e+003 3.16 3.16 0.629 216 7.14e+003 7.13e+003 3.15 3.15 0.627 217 7.2e+003 7.19e+003 3.15 3.15 0.627 218 7.26e+003 7.25e+003 3.15 3.15 0.627 219 7.32e+003 7.31e+003 3.15 3.15 0.627 220 7.38e+003 7.37e+003 3.15 3.15 0.627 221 7.44e+003 7.43e+003 3.15 3.15 0.626 222 7.5e+003 7.49e+003 3.15 3.15 0.627 223 7.56e+003 7.55e+003 3.15 3.15 0.626 224 7.62e+003 7.61e+003 3.15 3.15 0.626 225 7.68e+003 7.67e+003 3.15 3.15 0.626 226 7.74e+003 7.73e+003 3.14 3.14 0.624 227 7.8e+003 7.79e+003 3.14 3.14 0.624 228 7.86e+003 7.85e+003 3.14 3.14 0.624 229 7.92e+003 7.91e+003 3.14 3.14 0.624 230 7.98e+003 7.97e+003 3.14 3.14 0.624 231 8.04e+003 8.03e+003 3.13 3.13 0.623 232 8.1e+003 8.09e+003 3.13 3.13 0.623 233 8.16e+003 8.15e+003 3.12 3.12 0.621 234 8.22e+003 8.21e+003 3.12 3.12 0.621 235 8.28e+003 8.27e+003 3.12 3.12 0.621 236 8.34e+003 8.33e+003 3.12 3.12 0.621 237 8.4e+003 8.39e+003 3.12 3.12 0.621 238 8.46e+003 8.45e+003 3.12 3.12 0.621 239 8.52e+003 8.51e+003 3.11 3.11 0.62 240 8.58e+003 8.57e+003 3.11 3.11 0.62 241 8.64e+003 8.63e+003 3.11 3.11 0.62 242 8.7e+003 8.69e+003 3.11 3.11 0.618 243 8.76e+003 8.75e+003 3.11 3.11 0.62 244 8.82e+003 8.81e+003 3.11 3.11 0.618 245 8.88e+003 8.87e+003 3.11 3.11 0.618 246 8.94e+003 8.93e+003 3.11 3.11 0.618 247 9.e+003 8.99e+003 3.1 3.1 0.616 248 9.06e+003 9.05e+003 3.11 3.11 0.618 249 9.12e+003 9.11e+003 3.1 3.1 0.616 250 9.18e+003 9.17e+003 3.1 3.1 0.616 251 9.24e+003 9.23e+003 3.1 3.1 0.616 252 9.3e+003 9.29e+003 3.1 3.1 0.616 253 9.36e+003 9.35e+003 3.09 3.09 0.615 254 9.42e+003 9.41e+003 3.1 3.1 0.616 255 9.48e+003 9.47e+003 3.09 3.09 0.615 256 9.54e+003 9.53e+003 3.09 3.09 0.615 257 9.6e+003 9.59e+003 3.08 3.08 0.613 258 9.66e+003 9.65e+003 3.08 3.08 0.613 259 9.72e+003 9.71e+003 3.08 3.08 0.613 260 9.78e+003 9.77e+003 3.08 3.08 0.613 261 9.84e+003 9.83e+003 3.08 3.08 0.612 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 6 262 9.9e+003 9.89e+003 3.08 3.08 0.613 263 9.96e+003 9.95e+003 3.08 3.08 0.613 264 1.e+004 1.e+004 3.08 3.08 0.612 265 1.01e+004 1.01e+004 3.08 3.08 0.612 266 1.01e+004 1.01e+004 3.08 3.08 0.612 267 1.02e+004 1.02e+004 3.08 3.08 0.612 268 1.03e+004 1.03e+004 3.07 3.07 0.61 269 1.03e+004 1.03e+004 3.07 3.07 0.61 270 1.04e+004 1.04e+004 3.07 3.07 0.61 271 1.04e+004 1.04e+004 3.07 3.07 0.61 272 1.05e+004 1.05e+004 3.07 3.07 0.61 273 1.06e+004 1.06e+004 3.07 3.07 0.61 274 1.06e+004 1.06e+004 3.07 3.07 0.61 275 1.07e+004 1.07e+004 3.07 3.07 0.61 276 1.07e+004 1.07e+004 3.06 3.06 0.609 277 1.08e+004 1.08e+004 3.06 3.06 0.609 278 1.09e+004 1.09e+004 3.06 3.06 0.609 279 1.09e+004 1.09e+004 3.06 3.06 0.609 280 1.1e+004 1.1e+004 3.06 3.06 0.609 281 1.1e+004 1.1e+004 3.05 3.05 0.607 282 1.11e+004 1.11e+004 3.05 3.05 0.607 283 1.12e+004 1.12e+004 3.05 3.05 0.607 284 1.12e+004 1.12e+004 3.05 3.05 0.607 285 1.13e+004 1.13e+004 3.05 3.05 0.607 286 1.13e+004 1.13e+004 3.05 3.05 0.607 287 1.14e+004 1.14e+004 3.04 3.04 0.605 288 1.15e+004 1.15e+004 3.04 3.04 0.605 289 1.15e+004 1.15e+004 3.05 3.05 0.607 290 1.16e+004 1.16e+004 3.04 3.04 0.605 291 1.16e+004 1.16e+004 3.04 3.04 0.605 292 1.17e+004 1.17e+004 3.04 3.04 0.604 293 1.18e+004 1.18e+004 3.04 3.04 0.605 294 1.18e+004 1.18e+004 3.04 3.04 0.605 295 1.19e+004 1.19e+004 3.04 3.04 0.605 296 1.19e+004 1.19e+004 3.04 3.04 0.604 297 1.2e+004 1.2e+004 3.04 3.04 0.604 298 1.21e+004 1.21e+004 3.04 3.04 0.604 299 1.21e+004 1.21e+004 3.04 3.04 0.604 300 1.22e+004 1.22e+004 3.04 3.04 0.604 301 1.22e+004 1.22e+004 3.04 3.04 0.604 302 1.23e+004 1.23e+004 3.03 3.03 0.602 303 1.24e+004 1.24e+004 3.03 3.03 0.602 304 1.24e+004 1.24e+004 3.02 3.02 0.601 305 1.25e+004 1.25e+004 3.03 3.03 0.602 306 1.25e+004 1.25e+004 3.03 3.03 0.602 307 1.26e+004 1.26e+004 3.04 3.04 0.604 308 1.27e+004 1.27e+004 3.03 3.03 0.602 309 1.27e+004 1.27e+004 3.02 3.02 0.601 310 1.28e+004 1.28e+004 3.02 3.02 0.601 311 1.28e+004 1.28e+004 3.02 3.02 0.601 312 1.29e+004 1.29e+004 3.01 3.01 0.599 313 1.3e+004 1.3e+004 3.02 3.02 0.601 314 1.3e+004 1.3e+004 3.02 3.02 0.601 315 1.31e+004 1.31e+004 3.02 3.02 0.601 316 1.31e+004 1.31e+004 3.01 3.01 0.599 317 1.32e+004 1.32e+004 3.02 3.02 0.601 318 1.33e+004 1.33e+004 3.02 3.02 0.601 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 7 319 1.33e+004 1.33e+004 3.01 3.01 0.599 320 1.34e+004 1.34e+004 3.01 3.01 0.599 321 1.34e+004 1.34e+004 3.01 3.01 0.599 322 1.35e+004 1.35e+004 3.01 3.01 0.599 323 1.36e+004 1.36e+004 3.3.0.598 324 1.36e+004 1.36e+004 3.02 3.02 0.601 325 1.37e+004 1.37e+004 3.01 3.01 0.599 326 1.37e+004 1.37e+004 3.01 3.01 0.599 327 1.38e+004 1.38e+004 3.01 3.01 0.599 328 1.39e+004 1.39e+004 3.01 3.01 0.599 329 1.39e+004 1.39e+004 3.01 3.01 0.599 330 1.4e+004 1.4e+004 3.3.0.598 331 1.4e+004 1.4e+004 3.3.0.598 332 1.41e+004 1.41e+004 3.3.0.598 333 1.42e+004 1.42e+004 3.3.0.598 334 1.42e+004 1.42e+004 3.3.0.598 335 1.43e+004 1.43e+004 3.3.0.596 336 1.43e+004 1.43e+004 3.3.0.598 337 1.44e+004 1.44e+004 3.3.0.598 338 1.45e+004 1.45e+004 3.3.0.598 339 1.45e+004 1.45e+004 3.3.0.598 340 1.46e+004 1.46e+004 3.3.0.598 341 1.46e+004 1.46e+004 3.3.0.598 342 1.47e+004 1.47e+004 3.3.0.596 343 1.48e+004 1.48e+004 3.3.0.598 344 1.48e+004 1.48e+004 3.3.0.596 345 1.49e+004 1.49e+004 3.3.0.596 346 1.49e+004 1.49e+004 3.3.0.596 347 1.5e+004 1.5e+004 3.3.0.596 348 1.51e+004 1.51e+004 3.3.0.596 349 1.51e+004 1.51e+004 3.3.0.596 350 1.52e+004 1.52e+004 3.3.0.598 351 1.52e+004 1.52e+004 3.3.0.596 352 1.53e+004 1.53e+004 3.3.0.596 353 1.54e+004 1.54e+004 3.3.0.596 354 1.54e+004 1.54e+004 3.3.0.596 355 1.55e+004 1.55e+004 3.3.0.596 356 1.55e+004 1.55e+004 3.3.0.596 357 1.56e+004 1.56e+004 3.3.0.596 358 1.57e+004 1.57e+004 3.3.0.596 359 1.57e+004 1.57e+004 3.3.0.596 360 1.58e+004 1.58e+004 3.3.0.596 361 1.58e+004 1.58e+004 3.3.0.596 362 1.59e+004 1.59e+004 3.3.0.596 363 1.6e+004 1.6e+004 3.3.0.596 364 1.6e+004 1.6e+004 3.3.0.596 365 1.61e+004 1.61e+004 3.3.0.596 366 1.61e+004 1.61e+004 3.3.0.596 367 1.62e+004 1.62e+004 3.3.0.596 368 1.63e+004 1.63e+004 3.3.0.596 369 1.63e+004 1.63e+004 3.3.0.596 370 1.64e+004 1.64e+004 2.99 2.99 0.595 371 1.64e+004 1.64e+004 3.3.0.596 372 1.65e+004 1.65e+004 3.3.0.596 373 1.66e+004 1.66e+004 3.3.0.596 374 1.66e+004 1.66e+004 3.3.0.596 375 1.67e+004 1.67e+004 3.3.0.596 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 8 376 1.67e+004 1.67e+004 3.3.0.596 377 1.68e+004 1.68e+004 2.99 2.99 0.595 378 1.69e+004 1.69e+004 3.3.0.596 379 1.69e+004 1.69e+004 2.99 2.99 0.595 380 1.7e+004 1.7e+004 3.3.0.596 381 1.7e+004 1.7e+004 2.99 2.99 0.595 382 1.71e+004 1.71e+004 3.3.0.596 383 1.72e+004 1.72e+004 2.99 2.99 0.595 384 1.72e+004 1.72e+004 2.99 2.99 0.595 385 1.73e+004 1.73e+004 2.99 2.99 0.595 386 1.73e+004 1.73e+004 3.3.0.596 387 1.74e+004 1.74e+004 2.99 2.99 0.595 388 1.75e+004 1.75e+004 2.99 2.99 0.595 389 1.75e+004 1.75e+004 2.99 2.99 0.595 390 1.76e+004 1.76e+004 3.3.0.596 391 1.76e+004 1.76e+004 2.99 2.99 0.595 392 1.77e+004 1.77e+004 3.3.0.596 393 1.78e+004 1.78e+004 2.99 2.99 0.595 394 1.78e+004 1.78e+004 3.3.0.596 395 1.79e+004 1.79e+004 2.99 2.99 0.595 396 1.79e+004 1.79e+004 2.99 2.99 0.595 397 1.8e+004 1.8e+004 2.99 2.99 0.595 398 1.81e+004 1.81e+004 2.99 2.99 0.595 399 1.81e+004 1.81e+004 2.99 2.99 0.595 400 1.82e+004 1.82e+004 2.99 2.99 0.595 401 1.82e+004 1.82e+004 2.99 2.99 0.595 402 1.83e+004 1.83e+004 2.98 2.98 0.593 403 1.84e+004 1.84e+004 2.99 2.99 0.595 404 1.84e+004 1.84e+004 2.99 2.99 0.595 405 1.85e+004 1.85e+004 2.99 2.99 0.595 406 1.85e+004 1.85e+004 2.99 2.99 0.595 407 1.86e+004 1.86e+004 3.3.0.596 408 1.87e+004 1.87e+004 2.99 2.99 0.595 409 1.87e+004 1.87e+004 2.99 2.99 0.595 410 1.88e+004 1.88e+004 2.99 2.99 0.595 411 1.88e+004 1.88e+004 2.99 2.99 0.595 412 1.89e+004 1.89e+004 2.99 2.99 0.595 413 1.9e+004 1.9e+004 2.99 2.99 0.595 414 1.9e+004 1.9e+004 2.99 2.99 0.595 415 1.91e+004 1.91e+004 2.99 2.99 0.595 416 1.91e+004 1.91e+004 2.99 2.99 0.595 417 1.92e+004 1.92e+004 2.98 2.98 0.593 418 1.93e+004 1.93e+004 2.98 2.98 0.593 419 1.93e+004 1.93e+004 2.99 2.99 0.595 420 1.94e+004 1.94e+004 2.99 2.99 0.595 421 1.94e+004 1.94e+004 2.98 2.98 0.593 422 1.95e+004 1.95e+004 2.98 2.98 0.593 423 1.96e+004 1.96e+004 2.99 2.99 0.595 424 1.96e+004 1.96e+004 2.99 2.99 0.595 425 1.97e+004 1.97e+004 2.98 2.98 0.593 426 1.97e+004 1.97e+004 2.98 2.98 0.593 427 1.98e+004 1.98e+004 2.99 2.99 0.595 428 1.99e+004 1.99e+004 2.98 2.98 0.593 429 1.99e+004 1.99e+004 2.98 2.98 0.593 430 2.e+004 2.e+004 2.98 2.98 0.593 431 2.e+004 2.e+004 2.98 2.98 0.593 432 2.01e+004 2.01e+004 2.98 2.98 0.593 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 9 433 2.02e+004 2.02e+004 2.98 2.98 0.593 434 2.02e+004 2.02e+004 2.98 2.98 0.593 435 2.03e+004 2.03e+004 2.98 2.98 0.593 436 2.03e+004 2.03e+004 2.98 2.98 0.593 437 2.04e+004 2.04e+004 2.98 2.98 0.593 438 2.05e+004 2.05e+004 2.98 2.98 0.593 439 2.05e+004 2.05e+004 2.98 2.98 0.593 440 2.06e+004 2.06e+004 2.98 2.98 0.593 441 2.06e+004 2.06e+004 2.98 2.98 0.593 442 2.07e+004 2.07e+004 2.98 2.98 0.593 443 2.08e+004 2.08e+004 2.98 2.98 0.593 444 2.08e+004 2.08e+004 2.99 2.99 0.595 445 2.09e+004 2.09e+004 2.98 2.98 0.593 446 2.09e+004 2.09e+004 2.98 2.98 0.593 447 2.1e+004 2.1e+004 2.98 2.98 0.593 448 2.11e+004 2.11e+004 2.98 2.98 0.593 449 2.11e+004 2.11e+004 2.98 2.98 0.593 450 2.12e+004 2.12e+004 2.98 2.98 0.593 451 2.12e+004 2.12e+004 2.97 2.97 0.592 452 2.13e+004 2.13e+004 2.98 2.98 0.593 453 2.14e+004 2.14e+004 2.98 2.98 0.593 454 2.14e+004 2.14e+004 2.98 2.98 0.593 455 2.15e+004 2.15e+004 2.98 2.98 0.593 456 2.15e+004 2.15e+004 2.97 2.97 0.592 457 2.16e+004 2.16e+004 2.98 2.98 0.593 458 2.17e+004 2.17e+004 2.98 2.98 0.593 459 2.17e+004 2.17e+004 2.98 2.98 0.593 460 2.18e+004 2.18e+004 2.98 2.98 0.593 461 2.18e+004 2.18e+004 2.98 2.98 0.593 462 2.19e+004 2.19e+004 2.98 2.98 0.593 463 2.2e+004 2.2e+004 2.97 2.97 0.592 464 2.2e+004 2.2e+004 2.97 2.97 0.592 465 2.21e+004 2.21e+004 2.98 2.98 0.593 466 2.21e+004 2.21e+004 2.97 2.97 0.592 467 2.22e+004 2.22e+004 2.97 2.97 0.592 468 2.23e+004 2.23e+004 2.97 2.97 0.592 469 2.23e+004 2.23e+004 2.97 2.97 0.592 470 2.24e+004 2.24e+004 2.98 2.98 0.593 471 2.24e+004 2.24e+004 2.98 2.98 0.593 472 2.25e+004 2.25e+004 2.97 2.97 0.592 473 2.26e+004 2.26e+004 2.98 2.98 0.593 474 2.26e+004 2.26e+004 2.97 2.97 0.592 475 2.27e+004 2.27e+004 2.98 2.98 0.593 476 2.27e+004 2.27e+004 2.98 2.98 0.593 477 2.28e+004 2.28e+004 2.97 2.97 0.592 478 2.29e+004 2.29e+004 2.97 2.97 0.592 479 2.29e+004 2.29e+004 2.97 2.97 0.592 480 2.3e+004 2.3e+004 2.97 2.97 0.592 481 2.3e+004 2.3e+004 2.98 2.98 0.593 482 2.31e+004 2.31e+004 2.97 2.97 0.592 483 2.32e+004 2.32e+004 2.97 2.97 0.592 484 2.32e+004 2.32e+004 2.97 2.97 0.592 485 2.33e+004 2.33e+004 2.97 2.97 0.592 486 2.33e+004 2.33e+004 2.97 2.97 0.592 487 2.34e+004 2.34e+004 2.97 2.97 0.592 488 2.35e+004 2.35e+004 2.97 2.97 0.592 489 2.35e+004 2.35e+004 2.97 2.97 0.592 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 10 490 2.36e+004 2.36e+004 2.98 2.98 0.593 491 2.36e+004 2.36e+004 2.96 2.96 0.59 492 2.37e+004 2.37e+004 2.97 2.97 0.592 493 2.38e+004 2.38e+004 2.97 2.97 0.592 494 2.38e+004 2.38e+004 2.97 2.97 0.592 495 2.39e+004 2.39e+004 2.97 2.97 0.592 496 2.39e+004 2.39e+004 2.96 2.96 0.59 497 2.4e+004 2.4e+004 2.97 2.97 0.592 498 2.41e+004 2.41e+004 2.97 2.97 0.592 499 2.41e+004 2.41e+004 2.97 2.97 0.592 500 2.42e+004 2.42e+004 2.97 2.97 0.592 501 2.42e+004 2.42e+004 2.96 2.96 0.59 502 2.43e+004 2.43e+004 2.96 2.96 0.59 503 2.44e+004 2.44e+004 2.96 2.96 0.59 504 2.44e+004 2.44e+004 2.96 2.96 0.59 505 2.45e+004 2.45e+004 2.96 2.96 0.59 506 2.45e+004 2.45e+004 2.97 2.97 0.592 507 2.46e+004 2.46e+004 2.97 2.97 0.592 508 2.47e+004 2.47e+004 2.96 2.96 0.59 509 2.47e+004 2.47e+004 2.97 2.97 0.592 510 2.48e+004 2.48e+004 2.96 2.96 0.59 511 2.48e+004 2.48e+004 2.97 2.97 0.592 512 2.49e+004 2.49e+004 2.96 2.96 0.59 513 2.5e+004 2.5e+004 2.97 2.97 0.592 514 2.5e+004 2.5e+004 2.97 2.97 0.592 515 2.51e+004 2.51e+004 2.96 2.96 0.59 516 2.51e+004 2.51e+004 2.96 2.96 0.59 517 2.52e+004 2.52e+004 2.97 2.97 0.592 518 2.53e+004 2.53e+004 2.97 2.97 0.592 519 2.53e+004 2.53e+004 2.96 2.96 0.59 520 2.54e+004 2.54e+004 2.96 2.96 0.59 521 2.54e+004 2.54e+004 2.96 2.96 0.59 522 2.55e+004 2.55e+004 2.96 2.96 0.59 523 2.56e+004 2.56e+004 2.97 2.97 0.592 524 2.56e+004 2.56e+004 2.96 2.96 0.59 525 2.57e+004 2.57e+004 2.97 2.97 0.592 526 2.57e+004 2.57e+004 2.96 2.96 0.59 527 2.58e+004 2.58e+004 2.96 2.96 0.59 528 2.59e+004 2.59e+004 2.97 2.97 0.592 529 2.59e+004 2.59e+004 2.97 2.97 0.592 530 2.6e+004 2.6e+004 2.97 2.97 0.592 531 2.6e+004 2.6e+004 2.96 2.96 0.59 532 2.61e+004 2.61e+004 2.97 2.97 0.592 533 2.62e+004 2.62e+004 2.96 2.96 0.59 534 2.62e+004 2.62e+004 2.97 2.97 0.592 535 2.63e+004 2.63e+004 2.96 2.96 0.59 536 2.63e+004 2.63e+004 2.96 2.96 0.59 537 2.64e+004 2.64e+004 2.97 2.97 0.592 538 2.65e+004 2.65e+004 2.96 2.96 0.59 539 2.65e+004 2.65e+004 2.96 2.96 0.59 540 2.66e+004 2.66e+004 2.96 2.96 0.59 541 2.66e+004 2.66e+004 2.96 2.96 0.59 542 2.67e+004 2.67e+004 2.96 2.96 0.59 543 2.68e+004 2.68e+004 2.96 2.96 0.59 544 2.68e+004 2.68e+004 2.96 2.96 0.59 545 2.69e+004 2.69e+004 2.96 2.96 0.59 546 2.69e+004 2.69e+004 2.96 2.96 0.588 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 11 547 2.7e+004 2.7e+004 2.96 2.96 0.59 548 2.71e+004 2.71e+004 2.96 2.96 0.59 549 2.71e+004 2.71e+004 2.96 2.96 0.59 550 2.72e+004 2.72e+004 2.96 2.96 0.59 551 2.72e+004 2.72e+004 2.96 2.96 0.59 552 2.73e+004 2.73e+004 2.96 2.96 0.59 553 2.74e+004 2.74e+004 2.96 2.96 0.59 554 2.74e+004 2.74e+004 2.96 2.96 0.588 555 2.75e+004 2.75e+004 2.96 2.96 0.59 556 2.75e+004 2.75e+004 2.96 2.96 0.59 557 2.76e+004 2.76e+004 2.96 2.96 0.59 558 2.77e+004 2.77e+004 2.96 2.96 0.59 559 2.77e+004 2.77e+004 2.96 2.96 0.59 560 2.78e+004 2.78e+004 2.96 2.96 0.59 561 2.78e+004 2.78e+004 2.96 2.96 0.59 562 2.79e+004 2.79e+004 2.96 2.96 0.59 563 2.8e+004 2.8e+004 2.96 2.96 0.59 564 2.8e+004 2.8e+004 2.96 2.96 0.59 565 2.81e+004 2.81e+004 2.96 2.96 0.59 566 2.81e+004 2.81e+004 2.96 2.96 0.59 567 2.82e+004 2.82e+004 2.96 2.96 0.59 568 2.83e+004 2.83e+004 2.96 2.96 0.59 569 2.83e+004 2.83e+004 2.96 2.96 0.588 570 2.84e+004 2.84e+004 2.96 2.96 0.588 571 2.84e+004 2.84e+004 2.96 2.96 0.588 572 2.85e+004 2.85e+004 2.96 2.96 0.588 573 2.86e+004 2.86e+004 2.96 2.96 0.588 574 2.86e+004 2.86e+004 2.96 2.96 0.588 575 2.87e+004 2.87e+004 2.96 2.96 0.59 576 2.87e+004 2.87e+004 2.96 2.96 0.588 577 2.88e+004 2.88e+004 2.96 2.96 0.59 578 2.89e+004 2.89e+004 2.96 2.96 0.588 579 2.89e+004 2.89e+004 2.96 2.96 0.59 580 2.9e+004 2.9e+004 2.96 2.96 0.588 581 2.9e+004 2.9e+004 2.96 2.96 0.588 582 2.91e+004 2.91e+004 2.96 2.96 0.588 583 2.92e+004 2.92e+004 2.96 2.96 0.588 584 2.92e+004 2.92e+004 2.96 2.96 0.588 585 2.93e+004 2.93e+004 2.96 2.96 0.588 586 2.93e+004 2.93e+004 2.96 2.96 0.588 587 2.94e+004 2.94e+004 2.96 2.96 0.59 588 2.95e+004 2.95e+004 2.96 2.96 0.588 589 2.95e+004 2.95e+004 2.96 2.96 0.588 590 2.96e+004 2.96e+004 2.96 2.96 0.588 591 2.96e+004 2.96e+004 2.96 2.96 0.588 592 2.97e+004 2.97e+004 2.96 2.96 0.588 593 2.98e+004 2.98e+004 2.96 2.96 0.588 594 2.98e+004 2.98e+004 2.96 2.96 0.588 595 2.99e+004 2.99e+004 2.96 2.96 0.588 596 2.99e+004 2.99e+004 2.96 2.96 0.588 597 3.e+004 3.e+004 2.96 2.96 0.588 598 3.01e+004 3.01e+004 2.96 2.96 0.588 599 3.01e+004 3.01e+004 2.96 2.96 0.588 600 3.02e+004 3.02e+004 2.96 2.96 0.588 601 3.02e+004 3.02e+004 2.96 2.96 0.588 602 3.03e+004 3.03e+004 2.96 2.96 0.588 603 3.04e+004 3.04e+004 2.96 2.96 0.588 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 12 604 3.04e+004 3.04e+004 2.95 2.95 0.587 605 3.05e+004 3.05e+004 2.95 2.95 0.587 606 3.05e+004 3.05e+004 2.96 2.96 0.588 607 3.06e+004 3.06e+004 2.95 2.95 0.587 608 3.07e+004 3.07e+004 2.96 2.96 0.588 609 3.07e+004 3.07e+004 2.96 2.96 0.588 610 3.08e+004 3.08e+004 2.96 2.96 0.588 611 3.08e+004 3.08e+004 2.96 2.96 0.588 612 3.09e+004 3.09e+004 2.96 2.96 0.588 613 3.1e+004 3.1e+004 2.96 2.96 0.588 614 3.1e+004 3.1e+004 2.96 2.96 0.588 615 3.11e+004 3.11e+004 2.96 2.96 0.588 616 3.11e+004 3.11e+004 2.96 2.96 0.588 617 3.12e+004 3.12e+004 2.96 2.96 0.588 618 3.13e+004 3.13e+004 2.96 2.96 0.588 619 3.13e+004 3.13e+004 2.95 2.95 0.587 620 3.14e+004 3.14e+004 2.96 2.96 0.588 621 3.14e+004 3.14e+004 2.96 2.96 0.588 622 3.15e+004 3.15e+004 2.95 2.95 0.587 623 3.16e+004 3.16e+004 2.95 2.95 0.587 624 3.16e+004 3.16e+004 2.96 2.96 0.588 625 3.17e+004 3.17e+004 2.95 2.95 0.587 626 3.17e+004 3.17e+004 2.95 2.95 0.587 627 3.18e+004 3.18e+004 2.95 2.95 0.587 628 3.19e+004 3.19e+004 2.96 2.96 0.588 629 3.19e+004 3.19e+004 2.96 2.96 0.588 630 3.2e+004 3.2e+004 2.95 2.95 0.587 631 3.2e+004 3.2e+004 2.95 2.95 0.587 632 3.21e+004 3.21e+004 2.96 2.96 0.588 633 3.22e+004 3.22e+004 2.96 2.96 0.588 634 3.22e+004 3.22e+004 2.96 2.96 0.588 635 3.23e+004 3.23e+004 2.96 2.96 0.588 636 3.23e+004 3.23e+004 2.95 2.95 0.587 637 3.24e+004 3.24e+004 2.95 2.95 0.587 638 3.25e+004 3.25e+004 2.95 2.95 0.587 639 3.25e+004 3.25e+004 2.95 2.95 0.587 640 3.26e+004 3.26e+004 2.95 2.95 0.587 641 3.26e+004 3.26e+004 2.95 2.95 0.587 642 3.27e+004 3.27e+004 2.96 2.96 0.588 643 3.28e+004 3.28e+004 2.95 2.95 0.587 644 3.28e+004 3.28e+004 2.95 2.95 0.587 645 3.29e+004 3.29e+004 2.95 2.95 0.587 646 3.29e+004 3.29e+004 2.95 2.95 0.587 647 3.3e+004 3.3e+004 2.95 2.95 0.587 648 3.31e+004 3.31e+004 2.95 2.95 0.587 649 3.31e+004 3.31e+004 2.95 2.95 0.587 650 3.32e+004 3.32e+004 2.94 2.94 0.585 651 3.32e+004 3.32e+004 2.96 2.96 0.588 652 3.33e+004 3.33e+004 2.95 2.95 0.587 653 3.34e+004 3.34e+004 2.94 2.94 0.585 654 3.34e+004 3.34e+004 2.95 2.95 0.587 655 3.35e+004 3.35e+004 2.95 2.95 0.587 656 3.35e+004 3.35e+004 2.94 2.94 0.585 657 3.36e+004 3.36e+004 2.95 2.95 0.587 658 3.37e+004 3.37e+004 2.95 2.95 0.587 659 3.37e+004 3.37e+004 2.96 2.96 0.588 660 3.38e+004 3.38e+004 2.95 2.95 0.587 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 13 661 3.38e+004 3.38e+004 2.95 2.95 0.587 662 3.39e+004 3.39e+004 2.95 2.95 0.587 663 3.4e+004 3.4e+004 2.95 2.95 0.587 664 3.4e+004 3.4e+004 2.95 2.95 0.587 665 3.41e+004 3.41e+004 2.95 2.95 0.587 666 3.41e+004 3.41e+004 2.95 2.95 0.587 667 3.42e+004 3.42e+004 2.95 2.95 0.587 668 3.43e+004 3.43e+004 2.95 2.95 0.587 669 3.43e+004 3.43e+004 2.95 2.95 0.587 670 3.44e+004 3.44e+004 2.95 2.95 0.587 671 3.44e+004 3.44e+004 2.95 2.95 0.587 672 3.45e+004 3.45e+004 2.95 2.95 0.587 673 3.46e+004 3.46e+004 2.95 2.95 0.587 674 3.46e+004 3.46e+004 2.95 2.95 0.587 675 3.47e+004 3.47e+004 2.95 2.95 0.587 676 3.47e+004 3.47e+004 2.95 2.95 0.587 677 3.48e+004 3.48e+004 2.95 2.95 0.587 678 3.49e+004 3.49e+004 2.94 2.94 0.585 679 3.49e+004 3.49e+004 2.95 2.95 0.587 680 3.5e+004 3.5e+004 2.94 2.94 0.585 681 3.5e+004 3.5e+004 2.95 2.95 0.587 682 3.51e+004 3.51e+004 2.94 2.94 0.585 683 3.52e+004 3.52e+004 2.95 2.95 0.587 684 3.52e+004 3.52e+004 2.95 2.95 0.587 685 3.53e+004 3.53e+004 2.95 2.95 0.587 686 3.53e+004 3.53e+004 2.95 2.95 0.587 687 3.54e+004 3.54e+004 2.95 2.95 0.587 688 3.55e+004 3.55e+004 2.95 2.95 0.587 689 3.55e+004 3.55e+004 2.95 2.95 0.587 690 3.56e+004 3.56e+004 2.95 2.95 0.587 691 3.56e+004 3.56e+004 2.95 2.95 0.587 692 3.57e+004 3.57e+004 2.95 2.95 0.587 693 3.58e+004 3.58e+004 2.94 2.94 0.585 694 3.58e+004 3.58e+004 2.95 2.95 0.587 695 3.59e+004 3.59e+004 2.95 2.95 0.587 696 3.59e+004 3.59e+004 2.94 2.94 0.585 697 3.6e+004 3.6e+004 2.94 2.94 0.585 698 3.61e+004 3.61e+004 2.94 2.94 0.585 699 3.61e+004 3.61e+004 2.94 2.94 0.585 700 3.62e+004 3.62e+004 2.95 2.95 0.587 701 3.62e+004 3.62e+004 2.94 2.94 0.585 702 3.63e+004 3.63e+004 2.95 2.95 0.587 703 3.64e+004 3.64e+004 2.94 2.94 0.585 704 3.64e+004 3.64e+004 2.94 2.94 0.585 705 3.65e+004 3.65e+004 2.94 2.94 0.585 706 3.65e+004 3.65e+004 2.95 2.95 0.587 707 3.66e+004 3.66e+004 2.94 2.94 0.585 708 3.67e+004 3.67e+004 2.94 2.94 0.585 709 3.67e+004 3.67e+004 2.94 2.94 0.585 710 3.68e+004 3.68e+004 2.94 2.94 0.585 711 3.68e+004 3.68e+004 2.94 2.94 0.585 712 3.69e+004 3.69e+004 2.94 2.94 0.585 713 3.7e+004 3.7e+004 2.93 2.93 0.584 714 3.7e+004 3.7e+004 2.93 2.93 0.584 715 3.71e+004 3.71e+004 2.94 2.94 0.585 716 3.71e+004 3.71e+004 2.94 2.94 0.585 717 3.72e+004 3.72e+004 2.93 2.93 0.584 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ139CFH.slg Page 14 718 3.73e+004 3.73e+004 2.93 2.93 0.582 719 3.73e+004 3.73e+004 2.93 2.93 0.584 720 3.74e+004 3.74e+004 2.93 2.93 0.584 721 3.74e+004 3.74e+004 2.93 2.93 0.582 722 3.75e+004 3.75e+004 2.93 2.93 0.582 723 3.76e+004 3.76e+004 2.93 2.93 0.582 724 3.76e+004 3.76e+004 2.93 2.93 0.582 725 3.77e+004 3.77e+004 2.93 2.93 0.582 726 3.77e+004 3.77e+004 2.93 2.93 0.582 727 3.78e+004 3.78e+004 2.93 2.93 0.582 728 3.79e+004 3.79e+004 2.92 2.92 0.581 729 3.79e+004 3.79e+004 2.92 2.92 0.581 730 3.8e+004 3.8e+004 2.92 2.92 0.581 731 3.8e+004 3.8e+004 2.92 2.92 0.581 732 3.81e+004 3.81e+004 2.92 2.92 0.581 733 3.82e+004 3.82e+004 2.92 2.92 0.581 734 3.82e+004 3.82e+004 2.91 2.91 0.579 735 3.83e+004 3.83e+004 2.91 2.91 0.579 736 3.83e+004 3.83e+004 2.91 2.91 0.579 737 3.84e+004 3.84e+004 2.92 2.92 0.581 738 3.85e+004 3.85e+004 2.91 2.91 0.579 739 3.85e+004 3.85e+004 2.9 2.9 0.578 740 3.86e+004 3.86e+004 2.91 2.91 0.579 741 3.86e+004 3.86e+004 2.91 2.91 0.579 742 3.87e+004 3.87e+004 2.91 2.91 0.579 743 3.88e+004 3.88e+004 2.91 2.91 0.579 744 3.88e+004 3.88e+004 2.9 2.9 0.577 745 3.89e+004 3.89e+004 2.9 2.9 0.577 746 3.89e+004 3.89e+004 2.9 2.9 0.577 747 3.9e+004 3.9e+004 2.9 2.9 0.578 748 3.91e+004 3.91e+004 2.89 2.89 0.576 749 3.91e+004 3.91e+004 2.9 2.9 0.577 750 3.92e+004 3.92e+004 2.9 2.9 0.577 751 3.92e+004 3.92e+004 2.9 2.9 0.577 752 3.93e+004 3.93e+004 2.89 2.89 0.576 753 3.94e+004 3.94e+004 2.89 2.89 0.576 754 3.94e+004 3.94e+004 2.89 2.89 0.576 755 3.95e+004 3.95e+004 2.89 2.89 0.576 756 3.95e+004 3.95e+004 2.89 2.89 0.575 757 3.96e+004 3.96e+004 2.89 2.89 0.574 758 3.97e+004 3.97e+004 2.89 2.89 0.575 759 3.97e+004 3.97e+004 2.89 2.89 0.575 760 3.98e+004 3.98e+004 2.88 2.88 0.573 761 3.98e+004 3.98e+004 2.89 2.89 0.575 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ142FH.slg Page 1 Bouwer and Rice GraphFalling Head Slug Test October 28, 2021 Upper Piedmont Regional MSW Landfill Rougemont, NC Project Number: 1003-81 for Republic Services of North Carolina, LLC. Analysis by BLE PZ-142B Ho is 3.39 feet at 28. Seconds 0 1 2 Adjusted Time (Hours)Head Ratio (Ht/Ho)1.e-002 0.1 1. Bouwer and Rice parameter C = 1.38 ln(Re/Rw) = 2.223682e+000 Analysis starts at time 44. Seconds Analysis ends at time 84. minutes 145 Measurements analyzed from 17 to 161 Hydraulic Conductivity = 1.13e-005 cm/sec Transmissivity = 1.69e-004 ft2/min S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ142FH.slg Page 1 Falling Head Slug Test Site Name:Upper Piedmont Regional MSW Landfill Location:Rougemont, NC Test Date:October 28, 2021 Client:Republic Services of North Carolina, LLC. Project Number:1003-81 Import File:S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\ Well Label:PZ-142B Aquifer Thickness:7.64 feet Screen Length:5. feet Casing Radius:8.33e-002 feet Effective Radius:0.344 feet Static Water Level:0. feet Water Table to Screen Bottom:7.64 feet Anisotropy Ratio:2. Time Adjustment:28. Seconds Test starts with trial 0 There are 205 time and drawdown measurements Maximum head is 3.39 feet Minimum head is 0. feet Trial Time Adjusted Time Drawdown Head Head Ratio (Seconds)(Seconds)(feet)(feet) 1 28.0.3.39 3.39 1. 2 29.0.96 3.36 3.36 0.991 3 30.1.98 3.38 3.38 0.996 4 31.3.3.35 3.35 0.989 5 32.3.96 3.36 3.36 0.991 6 33.4.98 3.35 3.35 0.989 7 34.6.3.35 3.35 0.989 8 35.6.96 3.36 3.36 0.991 9 36.7.98 3.36 3.36 0.991 10 37.9.3.36 3.36 0.991 11 38.9.96 3.36 3.36 0.991 12 39.11.3.35 3.35 0.989 13 40.12.3.35 3.35 0.989 14 41.13.3.35 3.35 0.989 15 42.14.3.35 3.35 0.989 16 43.15.3.36 3.36 0.991 17 44.16.3.36 3.36 0.991 18 45.17.3.35 3.35 0.989 19 46.18.3.35 3.35 0.986 20 47.19.3.35 3.35 0.989 21 48.20.3.35 3.35 0.989 22 49.21.3.35 3.35 0.989 23 50.22.3.35 3.35 0.986 24 51.23.3.35 3.35 0.986 25 52.24.3.34 3.34 0.984 26 53.25.3.34 3.34 0.984 27 54.26.3.34 3.34 0.984 28 55.27.3.35 3.35 0.986 29 56.28.3.34 3.34 0.984 30 57.29.3.33 3.33 0.982 31 58.30.3.34 3.34 0.984 32 59.31.3.34 3.34 0.984 33 60.32.3.33 3.33 0.982 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ142FH.slg Page 2 34 70.42.3.32 3.32 0.979 35 80.52.3.31 3.31 0.975 36 90.62.3.29 3.29 0.971 37 100 72.3.29 3.29 0.968 38 110 82.3.28 3.28 0.966 39 120 92.3.27 3.27 0.964 40 130 102 3.27 3.27 0.964 41 140 112 3.25 3.25 0.959 42 150 122 3.25 3.25 0.957 43 160 132 3.24 3.24 0.955 44 170 142 3.23 3.23 0.953 45 180 152 3.22 3.22 0.95 46 190 162 3.21 3.21 0.945 47 200 172 3.21 3.21 0.946 48 210 182 3.19 3.19 0.939 49 220 192 3.19 3.19 0.939 50 230 202 3.18 3.18 0.937 51 240 212 3.17 3.17 0.934 52 250 222 3.16 3.16 0.932 53 260 232 3.15 3.15 0.93 54 270 242 3.15 3.15 0.927 55 280 252 3.14 3.14 0.925 56 290 262 3.12 3.12 0.92 57 300 272 3.12 3.12 0.92 58 310 282 3.11 3.11 0.918 59 320 292 3.1 3.1 0.915 60 330 302 3.09 3.09 0.91 61 340 312 3.09 3.09 0.91 62 350 322 3.08 3.08 0.907 63 360 332 3.07 3.07 0.905 64 370 342 3.06 3.06 0.901 65 380 352 3.05 3.05 0.9 66 390 362 3.05 3.05 0.898 67 400 372 3.04 3.04 0.897 68 410 382 3.03 3.03 0.894 69 420 392 3.02 3.02 0.892 70 430 402 3.03 3.03 0.892 71 440 412 3.02 3.02 0.89 72 450 422 3.01 3.01 0.888 73 460 432 3.3.0.885 74 470 442 3.3.0.883 75 480 452 3.3.0.883 76 490 462 2.98 2.98 0.878 77 500 472 2.97 2.97 0.876 78 510 482 2.96 2.96 0.874 79 520 492 2.96 2.96 0.874 80 530 502 2.95 2.95 0.869 81 540 512 2.94 2.94 0.867 82 550 522 2.93 2.93 0.864 83 560 532 2.92 2.92 0.862 84 570 542 2.92 2.92 0.862 85 580 552 2.92 2.92 0.859 86 590 562 2.91 2.91 0.857 87 600 572 2.9 2.9 0.854 88 660 632 2.86 2.86 0.843 89 720 692 2.81 2.81 0.83 90 780 752 2.78 2.78 0.818 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ142FH.slg Page 3 91 840 812 2.74 2.74 0.807 92 900 872 2.71 2.71 0.798 93 960 932 2.66 2.66 0.784 94 1.02e+003 992 2.63 2.63 0.775 95 1.08e+003 1.05e+003 2.59 2.59 0.762 96 1.14e+003 1.11e+003 2.56 2.56 0.753 97 1.2e+003 1.17e+003 2.52 2.52 0.742 98 1.26e+003 1.23e+003 2.48 2.48 0.732 99 1.32e+003 1.29e+003 2.44 2.44 0.721 100 1.38e+003 1.35e+003 2.42 2.42 0.714 101 1.44e+003 1.41e+003 2.39 2.39 0.705 102 1.5e+003 1.47e+003 2.35 2.35 0.694 103 1.56e+003 1.53e+003 2.32 2.32 0.684 104 1.62e+003 1.59e+003 2.29 2.29 0.675 105 1.68e+003 1.65e+003 2.26 2.26 0.666 106 1.74e+003 1.71e+003 2.23 2.23 0.657 107 1.8e+003 1.77e+003 2.2 2.2 0.648 108 1.86e+003 1.83e+003 2.17 2.17 0.638 109 1.92e+003 1.89e+003 2.14 2.14 0.63 110 1.98e+003 1.95e+003 2.11 2.11 0.621 111 2.04e+003 2.01e+003 2.09 2.09 0.615 112 2.1e+003 2.07e+003 2.05 2.05 0.606 113 2.16e+003 2.13e+003 2.03 2.03 0.599 114 2.22e+003 2.19e+003 2.2.0.59 115 2.28e+003 2.25e+003 1.97 1.97 0.58 116 2.34e+003 2.31e+003 1.95 1.95 0.576 117 2.4e+003 2.37e+003 1.92 1.92 0.567 118 2.46e+003 2.43e+003 1.9 1.9 0.56 119 2.52e+003 2.49e+003 1.87 1.87 0.55 120 2.58e+003 2.55e+003 1.84 1.84 0.541 121 2.64e+003 2.61e+003 1.81 1.81 0.534 122 2.7e+003 2.67e+003 1.79 1.79 0.527 123 2.76e+003 2.73e+003 1.76 1.76 0.52 124 2.82e+003 2.79e+003 1.74 1.74 0.513 125 2.88e+003 2.85e+003 1.72 1.72 0.506 126 2.94e+003 2.91e+003 1.69 1.69 0.497 127 3.e+003 2.97e+003 1.67 1.67 0.492 128 3.06e+003 3.03e+003 1.64 1.64 0.483 129 3.12e+003 3.09e+003 1.62 1.62 0.478 130 3.18e+003 3.15e+003 1.6 1.6 0.472 131 3.24e+003 3.21e+003 1.58 1.58 0.465 132 3.3e+003 3.27e+003 1.56 1.56 0.46 133 3.36e+003 3.33e+003 1.54 1.54 0.453 134 3.42e+003 3.39e+003 1.51 1.51 0.446 135 3.48e+003 3.45e+003 1.49 1.49 0.439 136 3.54e+003 3.51e+003 1.47 1.47 0.432 137 3.6e+003 3.57e+003 1.44 1.44 0.425 138 3.66e+003 3.63e+003 1.43 1.43 0.421 139 3.72e+003 3.69e+003 1.4 1.4 0.414 140 3.78e+003 3.75e+003 1.39 1.39 0.409 141 3.84e+003 3.81e+003 1.36 1.36 0.4 142 3.9e+003 3.87e+003 1.34 1.34 0.395 143 3.96e+003 3.93e+003 1.33 1.33 0.391 144 4.02e+003 3.99e+003 1.29 1.29 0.381 145 4.08e+003 4.05e+003 1.28 1.28 0.377 146 4.14e+003 4.11e+003 1.25 1.25 0.37 147 4.2e+003 4.17e+003 1.24 1.24 0.365 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ142FH.slg Page 4 148 4.26e+003 4.23e+003 1.22 1.22 0.358 149 4.32e+003 4.29e+003 1.2 1.2 0.353 150 4.38e+003 4.35e+003 1.18 1.18 0.348 151 4.44e+003 4.41e+003 1.16 1.16 0.341 152 4.5e+003 4.47e+003 1.14 1.14 0.337 153 4.56e+003 4.53e+003 1.13 1.13 0.333 154 4.62e+003 4.59e+003 1.11 1.11 0.328 155 4.68e+003 4.65e+003 1.1 1.1 0.324 156 4.74e+003 4.71e+003 1.07 1.07 0.317 157 4.8e+003 4.77e+003 1.06 1.06 0.312 158 4.86e+003 4.83e+003 1.04 1.04 0.307 159 4.92e+003 4.89e+003 1.01 1.01 0.298 160 4.98e+003 4.95e+003 0.972 0.972 0.287 161 5.04e+003 5.01e+003 0.933 0.933 0.275 162 5.1e+003 5.07e+003 0.894 0.894 0.264 163 5.16e+003 5.13e+003 0.854 0.854 0.252 164 5.22e+003 5.19e+003 0.823 0.823 0.243 165 5.28e+003 5.25e+003 0.799 0.799 0.236 166 5.34e+003 5.31e+003 0.76 0.76 0.224 167 5.4e+003 5.37e+003 0.729 0.729 0.215 168 5.46e+003 5.43e+003 0.697 0.697 0.205 169 5.52e+003 5.49e+003 0.674 0.674 0.199 170 5.58e+003 5.55e+003 0.634 0.634 0.187 171 5.64e+003 5.61e+003 0.619 0.619 0.182 172 5.7e+003 5.67e+003 0.587 0.587 0.173 173 5.76e+003 5.73e+003 0.564 0.564 0.166 174 5.82e+003 5.79e+003 0.534 0.534 0.157 175 5.88e+003 5.85e+003 0.511 0.511 0.151 176 5.94e+003 5.91e+003 0.492 0.492 0.145 177 6.e+003 5.97e+003 0.466 0.466 0.137 178 6.06e+003 6.03e+003 0.448 0.448 0.132 179 6.12e+003 6.09e+003 0.42 0.42 0.124 180 6.18e+003 6.15e+003 0.405 0.405 0.119 181 6.24e+003 6.21e+003 0.391 0.391 0.115 182 6.3e+003 6.27e+003 0.375 0.375 0.111 183 6.36e+003 6.33e+003 0.356 0.356 0.105 184 6.42e+003 6.39e+003 0.34 0.34 0.1 185 6.48e+003 6.45e+003 0.327 0.327 9.64e-002 186 6.54e+003 6.51e+003 0.312 0.312 9.2e-002 187 6.6e+003 6.57e+003 0.296 0.296 8.73e-002 188 6.66e+003 6.63e+003 0.276 0.276 8.14e-002 189 6.72e+003 6.69e+003 0.263 0.263 7.75e-002 190 6.78e+003 6.75e+003 0.256 0.256 7.55e-002 191 6.84e+003 6.81e+003 0.234 0.234 6.9e-002 192 6.9e+003 6.87e+003 0.226 0.226 6.66e-002 193 6.96e+003 6.93e+003 0.218 0.218 6.43e-002 194 7.02e+003 6.99e+003 0.194 0.194 5.72e-002 195 7.08e+003 7.05e+003 0.186 0.186 5.48e-002 196 7.14e+003 7.11e+003 0.186 0.186 5.48e-002 197 7.2e+003 7.17e+003 0.167 0.167 4.92e-002 198 7.26e+003 7.23e+003 0.153 0.153 4.51e-002 199 7.32e+003 7.29e+003 0.146 0.146 4.3e-002 200 7.38e+003 7.35e+003 0.139 0.139 4.1e-002 201 7.44e+003 7.41e+003 0.12 0.12 3.54e-002 202 7.5e+003 7.47e+003 0.112 0.112 3.3e-002 203 7.56e+003 7.53e+003 0.115 0.115 3.39e-002 204 7.62e+003 7.59e+003 0.1 0.1 2.95e-002 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ142FH.slg Page 5 205 7.68e+003 7.65e+003 9.2e-002 9.2e-002 2.71e-002 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ148FH.slg Page 1 Bouwer and Rice GraphFalling Head Slug Test August 17, 2021 Upper Piedmont Regional MSW Landfill Rougemont, NC Project Number: 1003-81 for Republic Services of North Carolina, LLC. Analysis by BLE PZ-148B Ho is 2.71 feet at 110 Seconds 0 1 2 Adjusted Time (Hours)Head Ratio (Ht/Ho)1.e-002 0.1 1. Bouwer and Rice parameter C = 1.97 ln(Re/Rw) = 2.788874e+000 Analysis starts at time 390 Seconds Analysis ends at time 76. minutes 88 Measurements analyzed from 29 to 116 47 Points not plotted because head ratio <= 0.0 These points are not included in the analysis Hydraulic Conductivity = 3.88e-005 cm/sec Transmissivity = 1.15e-003 ft2/min S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ148FH.slg Page 1 Falling Head Slug Test Site Name:Upper Piedmont Regional MSW Landfill Location:Rougemont, NC Test Date:August 17, 2021 Client:Republic Services of North Carolina, LLC. Project Number:1003-81 Import File:S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\ Well Label:PZ-148B Aquifer Thickness:15.1 feet Screen Length:10. feet Casing Radius:8.33e-002 feet Effective Radius:0.344 feet Static Water Level:0. feet Water Table to Screen Bottom:15.1 feet Anisotropy Ratio:2. Time Adjustment:110 Seconds Test starts with trial 0 There are 184 time and drawdown measurements Maximum head is 2.71 feet Minimum head is 0. feet Trial Time Adjusted Time Drawdown Head Head Ratio (Seconds)(Seconds)(feet)(feet) 1 110 0.2.71 2.71 1. 2 120 10.2.53 2.53 0.934 3 130 20.2.43 2.43 0.896 4 140 30.2.33 2.33 0.858 5 150 40.2.25 2.25 0.829 6 160 50.2.19 2.19 0.806 7 170 60.2.14 2.14 0.79 8 180 70.2.14 2.14 0.787 9 190 80.2.1 2.1 0.773 10 200 90.2.06 2.06 0.759 11 210 100 2.02 2.02 0.744 12 220 110 1.99 1.99 0.735 13 230 120 1.96 1.96 0.721 14 240 130 1.93 1.93 0.712 15 250 140 1.9 1.9 0.701 16 260 150 1.87 1.87 0.69 17 270 160 1.83 1.83 0.675 18 280 170 1.8 1.8 0.664 19 290 180 1.78 1.78 0.655 20 300 190 1.74 1.74 0.64 21 310 200 1.71 1.71 0.629 22 320 210 1.68 1.68 0.618 23 330 220 1.64 1.64 0.603 24 340 230 1.61 1.61 0.592 25 350 240 1.57 1.57 0.58 26 360 250 1.54 1.54 0.569 27 370 260 1.51 1.51 0.557 28 380 270 1.47 1.47 0.543 29 390 280 1.45 1.45 0.534 30 400 290 1.43 1.43 0.525 31 410 300 1.4 1.4 0.514 32 420 310 1.37 1.37 0.505 33 430 320 1.34 1.34 0.494 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ148FH.slg Page 2 34 440 330 1.31 1.31 0.482 35 450 340 1.29 1.29 0.476 36 460 350 1.25 1.25 0.462 37 470 360 1.23 1.23 0.453 38 480 370 1.21 1.21 0.444 39 490 380 1.18 1.18 0.436 40 500 390 1.16 1.16 0.427 41 510 400 1.14 1.14 0.421 42 520 410 1.12 1.12 0.413 43 530 420 1.1 1.1 0.404 44 540 430 1.07 1.07 0.395 45 550 440 1.05 1.05 0.387 46 560 450 1.02 1.02 0.378 47 570 460 1.01 1.01 0.372 48 580 470 0.986 0.986 0.363 49 590 480 0.97 0.97 0.357 50 600 490 0.947 0.947 0.349 51 660 550 0.846 0.846 0.312 52 720 610 0.736 0.736 0.271 53 780 670 0.665 0.665 0.245 54 840 730 0.588 0.588 0.217 55 900 790 0.533 0.533 0.196 56 960 850 0.478 0.478 0.176 57 1.02e+003 910 0.415 0.415 0.153 58 1.08e+003 970 0.376 0.376 0.139 59 1.14e+003 1.03e+003 0.336 0.336 0.124 60 1.2e+003 1.09e+003 0.305 0.305 0.112 61 1.26e+003 1.15e+003 0.281 0.281 0.104 62 1.32e+003 1.21e+003 0.25 0.25 9.21e-002 63 1.38e+003 1.27e+003 0.226 0.226 8.33e-002 64 1.44e+003 1.33e+003 0.203 0.203 7.48e-002 65 1.5e+003 1.39e+003 0.179 0.179 6.6e-002 66 1.56e+003 1.45e+003 0.171 0.171 6.3e-002 67 1.62e+003 1.51e+003 0.156 0.156 5.75e-002 68 1.68e+003 1.57e+003 0.14 0.14 5.16e-002 69 1.74e+003 1.63e+003 0.124 0.124 4.57e-002 70 1.8e+003 1.69e+003 0.124 0.124 4.57e-002 71 1.86e+003 1.75e+003 0.116 0.116 4.27e-002 72 1.92e+003 1.81e+003 0.108 0.108 3.98e-002 73 1.98e+003 1.87e+003 9.3e-002 9.3e-002 3.43e-002 74 2.04e+003 1.93e+003 8.5e-002 8.5e-002 3.13e-002 75 2.1e+003 1.99e+003 9.4e-002 9.4e-002 3.46e-002 76 2.16e+003 2.05e+003 7.8e-002 7.8e-002 2.87e-002 77 2.22e+003 2.11e+003 6.9e-002 6.9e-002 2.54e-002 78 2.28e+003 2.17e+003 7.e-002 7.e-002 2.58e-002 79 2.34e+003 2.23e+003 6.2e-002 6.2e-002 2.28e-002 80 2.4e+003 2.29e+003 6.2e-002 6.2e-002 2.28e-002 81 2.46e+003 2.35e+003 6.2e-002 6.2e-002 2.28e-002 82 2.52e+003 2.41e+003 5.5e-002 5.5e-002 2.03e-002 83 2.58e+003 2.47e+003 5.5e-002 5.5e-002 2.03e-002 84 2.64e+003 2.53e+003 5.3e-002 5.3e-002 1.95e-002 85 2.7e+003 2.59e+003 4.7e-002 4.7e-002 1.73e-002 86 2.76e+003 2.65e+003 4.5e-002 4.5e-002 1.66e-002 87 2.82e+003 2.71e+003 4.7e-002 4.7e-002 1.73e-002 88 2.88e+003 2.77e+003 4.7e-002 4.7e-002 1.73e-002 89 2.94e+003 2.83e+003 3.9e-002 3.9e-002 1.44e-002 90 3.e+003 2.89e+003 3.9e-002 3.9e-002 1.44e-002 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ148FH.slg Page 3 91 3.06e+003 2.95e+003 3.9e-002 3.9e-002 1.44e-002 92 3.12e+003 3.01e+003 3.9e-002 3.9e-002 1.44e-002 93 3.18e+003 3.07e+003 3.9e-002 3.9e-002 1.44e-002 94 3.24e+003 3.13e+003 3.9e-002 3.9e-002 1.44e-002 95 3.3e+003 3.19e+003 3.1e-002 3.1e-002 1.14e-002 96 3.36e+003 3.25e+003 3.9e-002 3.9e-002 1.44e-002 97 3.42e+003 3.31e+003 3.9e-002 3.9e-002 1.44e-002 98 3.48e+003 3.37e+003 3.1e-002 3.1e-002 1.14e-002 99 3.54e+003 3.43e+003 3.9e-002 3.9e-002 1.44e-002 100 3.6e+003 3.49e+003 3.1e-002 3.1e-002 1.14e-002 101 3.66e+003 3.55e+003 3.1e-002 3.1e-002 1.14e-002 102 3.72e+003 3.61e+003 2.3e-002 2.3e-002 8.47e-003 103 3.78e+003 3.67e+003 3.1e-002 3.1e-002 1.14e-002 104 3.84e+003 3.73e+003 2.3e-002 2.3e-002 8.47e-003 105 3.9e+003 3.79e+003 2.3e-002 2.3e-002 8.47e-003 106 3.96e+003 3.85e+003 2.3e-002 2.3e-002 8.47e-003 107 4.02e+003 3.91e+003 2.3e-002 2.3e-002 8.47e-003 108 4.08e+003 3.97e+003 2.3e-002 2.3e-002 8.47e-003 109 4.14e+003 4.03e+003 2.3e-002 2.3e-002 8.47e-003 110 4.2e+003 4.09e+003 2.3e-002 2.3e-002 8.47e-003 111 4.26e+003 4.15e+003 1.5e-002 1.5e-002 5.53e-003 112 4.32e+003 4.21e+003 2.3e-002 2.3e-002 8.47e-003 113 4.38e+003 4.27e+003 2.3e-002 2.3e-002 8.47e-003 114 4.44e+003 4.33e+003 2.3e-002 2.3e-002 8.47e-003 115 4.5e+003 4.39e+003 2.3e-002 2.3e-002 8.47e-003 116 4.56e+003 4.45e+003 1.5e-002 1.5e-002 5.53e-003 117 4.62e+003 4.51e+003 2.3e-002 2.3e-002 8.47e-003 118 4.68e+003 4.57e+003 2.3e-002 2.3e-002 8.47e-003 119 4.74e+003 4.63e+003 1.5e-002 1.5e-002 5.53e-003 120 4.8e+003 4.69e+003 1.5e-002 1.5e-002 5.53e-003 121 4.86e+003 4.75e+003 1.5e-002 1.5e-002 5.53e-003 122 4.92e+003 4.81e+003 1.5e-002 1.5e-002 5.53e-003 123 4.98e+003 4.87e+003 1.5e-002 1.5e-002 5.53e-003 124 5.04e+003 4.93e+003 1.5e-002 1.5e-002 5.53e-003 125 5.1e+003 4.99e+003 1.5e-002 1.5e-002 5.53e-003 126 5.16e+003 5.05e+003 1.5e-002 1.5e-002 5.53e-003 127 5.22e+003 5.11e+003 1.5e-002 1.5e-002 5.53e-003 128 5.28e+003 5.17e+003 7.e-003 7.e-003 2.58e-003 129 5.34e+003 5.23e+003 1.5e-002 1.5e-002 5.53e-003 130 5.4e+003 5.29e+003 7.e-003 7.e-003 2.58e-003 131 5.46e+003 5.35e+003 7.e-003 7.e-003 2.58e-003 132 5.52e+003 5.41e+003 1.5e-002 1.5e-002 5.53e-003 133 5.58e+003 5.47e+003 7.e-003 7.e-003 2.58e-003 134 5.64e+003 5.53e+003 7.e-003 7.e-003 2.58e-003 135 5.7e+003 5.59e+003 1.5e-002 1.5e-002 5.53e-003 136 5.76e+003 5.65e+003 7.e-003 7.e-003 2.58e-003 137 5.82e+003 5.71e+003 7.e-003 7.e-003 2.58e-003 138 5.88e+003 5.77e+003 1.5e-002 1.5e-002 5.53e-003 139 5.94e+003 5.83e+003 7.e-003 7.e-003 2.58e-003 140 6.e+003 5.89e+003 7.e-003 7.e-003 2.58e-003 141 6.06e+003 5.95e+003 7.e-003 7.e-003 2.58e-003 142 6.12e+003 6.01e+003 7.e-003 7.e-003 2.58e-003 143 6.18e+003 6.07e+003 1.5e-002 1.5e-002 5.53e-003 144 6.24e+003 6.13e+003 1.5e-002 1.5e-002 5.53e-003 145 6.3e+003 6.19e+003 7.e-003 7.e-003 2.58e-003 146 6.36e+003 6.25e+003 7.e-003 7.e-003 2.58e-003 147 6.42e+003 6.31e+003 7.e-003 7.e-003 2.58e-003 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ148FH.slg Page 4 148 6.48e+003 6.37e+003 7.e-003 7.e-003 2.58e-003 149 6.54e+003 6.43e+003 1.5e-002 1.5e-002 5.53e-003 150 6.6e+003 6.49e+003 7.e-003 7.e-003 2.58e-003 151 6.66e+003 6.55e+003 7.e-003 7.e-003 2.58e-003 152 6.72e+003 6.61e+003 1.5e-002 1.5e-002 5.53e-003 153 6.78e+003 6.67e+003 7.e-003 7.e-003 2.58e-003 154 6.84e+003 6.73e+003 1.5e-002 1.5e-002 5.53e-003 155 6.9e+003 6.79e+003 7.e-003 7.e-003 2.58e-003 156 6.96e+003 6.85e+003 7.e-003 7.e-003 2.58e-003 157 7.02e+003 6.91e+003 7.e-003 7.e-003 2.58e-003 158 7.08e+003 6.97e+003 7.e-003 7.e-003 2.58e-003 159 7.14e+003 7.03e+003 7.e-003 7.e-003 2.58e-003 160 7.2e+003 7.09e+003 7.e-003 7.e-003 2.58e-003 161 7.26e+003 7.15e+003 1.5e-002 1.5e-002 5.53e-003 162 7.32e+003 7.21e+003 7.e-003 7.e-003 2.58e-003 163 7.38e+003 7.27e+003 7.e-003 7.e-003 2.58e-003 164 7.44e+003 7.33e+003 7.e-003 7.e-003 2.58e-003 165 7.5e+003 7.39e+003 7.e-003 7.e-003 2.58e-003 166 7.56e+003 7.45e+003 7.e-003 7.e-003 2.58e-003 167 7.62e+003 7.51e+003 7.e-003 7.e-003 2.58e-003 168 7.68e+003 7.57e+003 7.e-003 7.e-003 2.58e-003 169 7.74e+003 7.63e+003 7.e-003 7.e-003 2.58e-003 170 7.8e+003 7.69e+003 7.e-003 7.e-003 2.58e-003 171 7.86e+003 7.75e+003 7.e-003 7.e-003 2.58e-003 172 7.92e+003 7.81e+003 7.e-003 7.e-003 2.58e-003 173 7.98e+003 7.87e+003 7.e-003 7.e-003 2.58e-003 174 8.04e+003 7.93e+003 7.e-003 7.e-003 2.58e-003 175 8.1e+003 7.99e+003 7.e-003 7.e-003 2.58e-003 176 8.16e+003 8.05e+003 7.e-003 7.e-003 2.58e-003 177 8.22e+003 8.11e+003 7.e-003 7.e-003 2.58e-003 178 8.28e+003 8.17e+003 7.e-003 7.e-003 2.58e-003 179 8.34e+003 8.23e+003 7.e-003 7.e-003 2.58e-003 180 8.4e+003 8.29e+003 7.e-003 7.e-003 2.58e-003 181 8.46e+003 8.35e+003 7.e-003 7.e-003 2.58e-003 182 8.52e+003 8.41e+003 7.e-003 7.e-003 2.58e-003 183 8.58e+003 8.47e+003 0.0.0. 184 8.64e+003 8.53e+003 0.0.0. S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ153FH.slg Page 1 Bouwer and Rice GraphFalling Head Slug Test February 16, 2022 Upper Piedmont Regional MSW Landfill Rougemont, NC Project Number: 1003-81 for Republic Services of North Carolina, LLC. Analysis by BLE PZ-153B Ho is 2.78 feet at 12. Seconds 0 1 2 3 Adjusted Time (Hours)Head Ratio (Ht/Ho)1.e-002 0.1 1. Bouwer and Rice parameter C = 1.65 ln(Re/Rw) = 2.278255e+000 Analysis starts at time 26. Seconds Analysis ends at time 167 minutes 246 Measurements analyzed from 15 to 260 Hydraulic Conductivity = 6.68e-006 cm/sec Transmissivity = 9.54e-005 ft2/min S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ153FH.slg Page 1 Falling Head Slug Test Site Name:Upper Piedmont Regional MSW Landfill Location:Rougemont, NC Test Date:February 16, 2022 Client:Republic Services of North Carolina, LLC. Project Number:1003-81 Import File:S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\ Well Label:PZ-153B Aquifer Thickness:7.26 feet Screen Length:10. feet Casing Radius:8.33e-002 feet Effective Radius:0.344 feet Static Water Level:0. feet Water Table to Screen Bottom:7.26 feet Anisotropy Ratio:2. Time Adjustment:12. Seconds Test starts with trial 0 There are 277 time and drawdown measurements Maximum head is 2.78 feet Minimum head is 0. feet Trial Time Adjusted Time Drawdown Head Head Ratio (Seconds)(Seconds)(feet)(feet) 1 12.0.2.78 2.78 1. 2 13.1.02 2.24 2.24 0.808 3 14.1.98 2.17 2.17 0.779 4 15.3.2.12 2.12 0.762 5 16.4.02 2.09 2.09 0.754 6 17.4.98 2.09 2.09 0.751 7 18.6.2.06 2.06 0.74 8 19.7.02 2.06 2.06 0.74 9 20.7.98 2.07 2.07 0.745 10 21.9.2.05 2.05 0.739 11 22.10.2.05 2.05 0.737 12 23.11.2.03 2.03 0.731 13 24.12.2.02 2.02 0.728 14 25.13.2.02 2.02 0.725 15 26.14.2.01 2.01 0.722 16 27.15.1.99 1.99 0.717 17 28.16.1.99 1.99 0.717 18 29.17.1.98 1.98 0.714 19 30.18.1.98 1.98 0.713 20 31.19.1.97 1.97 0.711 21 32.20.1.97 1.97 0.708 22 33.21.1.96 1.96 0.705 23 34.22.1.96 1.96 0.705 24 35.23.1.96 1.96 0.705 25 36.24.1.95 1.95 0.702 26 37.25.1.96 1.96 0.705 27 38.26.1.95 1.95 0.702 28 39.27.1.94 1.94 0.699 29 40.28.1.94 1.94 0.699 30 41.29.1.94 1.94 0.699 31 42.30.1.95 1.95 0.702 32 43.31.1.94 1.94 0.697 33 44.32.1.93 1.93 0.696 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ153FH.slg Page 2 34 45.33.1.93 1.93 0.696 35 46.34.1.93 1.93 0.694 36 47.35.1.93 1.93 0.696 37 48.36.1.93 1.93 0.693 38 49.37.1.93 1.93 0.693 39 50.38.1.93 1.93 0.693 40 51.39.1.93 1.93 0.693 41 52.40.1.93 1.93 0.693 42 53.41.1.93 1.93 0.693 43 54.42.1.92 1.92 0.69 44 55.43.1.93 1.93 0.693 45 56.44.1.93 1.93 0.693 46 57.45.1.92 1.92 0.69 47 58.46.1.92 1.92 0.69 48 59.47.1.92 1.92 0.693 49 60.48.1.92 1.92 0.69 50 70.58.1.91 1.91 0.687 51 80.68.1.9 1.9 0.684 52 90.78.1.89 1.89 0.681 53 100 88.1.89 1.89 0.679 54 110 98.1.89 1.89 0.679 55 120 108 1.88 1.88 0.676 56 130 118 1.87 1.87 0.674 57 140 128 1.86 1.86 0.671 58 150 138 1.86 1.86 0.668 59 160 148 1.85 1.85 0.665 60 170 158 1.85 1.85 0.665 61 180 168 1.84 1.84 0.661 62 190 178 1.84 1.84 0.661 63 200 188 1.83 1.83 0.658 64 210 198 1.82 1.82 0.654 65 220 208 1.82 1.82 0.654 66 230 218 1.81 1.81 0.652 67 240 228 1.8 1.8 0.648 68 250 238 1.8 1.8 0.649 69 260 248 1.8 1.8 0.647 70 270 258 1.79 1.79 0.644 71 280 268 1.79 1.79 0.644 72 290 278 1.78 1.78 0.641 73 300 288 1.77 1.77 0.639 74 310 298 1.77 1.77 0.639 75 320 308 1.76 1.76 0.633 76 330 318 1.76 1.76 0.633 77 340 328 1.77 1.77 0.636 78 350 338 1.76 1.76 0.633 79 360 348 1.76 1.76 0.633 80 370 358 1.76 1.76 0.633 81 380 368 1.76 1.76 0.633 82 390 378 1.75 1.75 0.63 83 400 388 1.75 1.75 0.63 84 410 398 1.76 1.76 0.633 85 420 408 1.75 1.75 0.63 86 430 418 1.75 1.75 0.63 87 440 428 1.76 1.76 0.633 88 450 438 1.75 1.75 0.63 89 460 448 1.75 1.75 0.63 90 470 458 1.74 1.74 0.627 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ153FH.slg Page 3 91 480 468 1.74 1.74 0.627 92 490 478 1.74 1.74 0.625 93 500 488 1.74 1.74 0.625 94 510 498 1.73 1.73 0.622 95 520 508 1.72 1.72 0.619 96 530 518 1.72 1.72 0.619 97 540 528 1.71 1.71 0.616 98 550 538 1.71 1.71 0.616 99 560 548 1.7 1.7 0.613 100 570 558 1.7 1.7 0.611 101 580 568 1.7 1.7 0.611 102 590 578 1.69 1.69 0.608 103 600 588 1.69 1.69 0.608 104 660 648 1.66 1.66 0.598 105 720 708 1.64 1.64 0.59 106 780 768 1.61 1.61 0.579 107 840 828 1.59 1.59 0.574 108 900 888 1.57 1.57 0.566 109 960 948 1.56 1.56 0.563 110 1.02e+003 1.01e+003 1.54 1.54 0.554 111 1.08e+003 1.07e+003 1.53 1.53 0.551 112 1.14e+003 1.13e+003 1.52 1.52 0.546 113 1.2e+003 1.19e+003 1.51 1.51 0.543 114 1.26e+003 1.25e+003 1.48 1.48 0.534 115 1.32e+003 1.31e+003 1.47 1.47 0.53 116 1.38e+003 1.37e+003 1.47 1.47 0.528 117 1.44e+003 1.43e+003 1.45 1.45 0.522 118 1.5e+003 1.49e+003 1.44 1.44 0.517 119 1.56e+003 1.55e+003 1.42 1.42 0.512 120 1.62e+003 1.61e+003 1.41 1.41 0.508 121 1.68e+003 1.67e+003 1.4 1.4 0.503 122 1.74e+003 1.73e+003 1.39 1.39 0.5 123 1.8e+003 1.79e+003 1.37 1.37 0.495 124 1.86e+003 1.85e+003 1.36 1.36 0.489 125 1.92e+003 1.91e+003 1.35 1.35 0.486 126 1.98e+003 1.97e+003 1.34 1.34 0.481 127 2.04e+003 2.03e+003 1.33 1.33 0.478 128 2.1e+003 2.09e+003 1.31 1.31 0.472 129 2.16e+003 2.15e+003 1.3 1.3 0.469 130 2.22e+003 2.21e+003 1.3 1.3 0.467 131 2.28e+003 2.27e+003 1.29 1.29 0.464 132 2.34e+003 2.33e+003 1.28 1.28 0.46 133 2.4e+003 2.39e+003 1.26 1.26 0.455 134 2.46e+003 2.45e+003 1.25 1.25 0.45 135 2.52e+003 2.51e+003 1.24 1.24 0.447 136 2.58e+003 2.57e+003 1.22 1.22 0.438 137 2.64e+003 2.63e+003 1.21 1.21 0.435 138 2.7e+003 2.69e+003 1.19 1.19 0.429 139 2.76e+003 2.75e+003 1.18 1.18 0.424 140 2.82e+003 2.81e+003 1.16 1.16 0.418 141 2.88e+003 2.87e+003 1.15 1.15 0.412 142 2.94e+003 2.93e+003 1.13 1.13 0.407 143 3.e+003 2.99e+003 1.12 1.12 0.404 144 3.06e+003 3.05e+003 1.1 1.1 0.395 145 3.12e+003 3.11e+003 1.09 1.09 0.391 146 3.18e+003 3.17e+003 1.08 1.08 0.389 147 3.24e+003 3.23e+003 1.07 1.07 0.386 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ153FH.slg Page 4 148 3.3e+003 3.29e+003 1.07 1.07 0.387 149 3.36e+003 3.35e+003 1.06 1.06 0.381 150 3.42e+003 3.41e+003 1.05 1.05 0.378 151 3.48e+003 3.47e+003 1.04 1.04 0.375 152 3.54e+003 3.53e+003 1.03 1.03 0.373 153 3.6e+003 3.59e+003 1.03 1.03 0.371 154 3.66e+003 3.65e+003 1.02 1.02 0.369 155 3.72e+003 3.71e+003 1.01 1.01 0.365 156 3.78e+003 3.77e+003 1.01 1.01 0.364 157 3.84e+003 3.83e+003 1.01 1.01 0.364 158 3.9e+003 3.89e+003 1.1.0.361 159 3.96e+003 3.95e+003 0.996 0.996 0.359 160 4.02e+003 4.01e+003 0.988 0.988 0.356 161 4.08e+003 4.07e+003 0.98 0.98 0.353 162 4.14e+003 4.13e+003 0.972 0.972 0.35 163 4.2e+003 4.19e+003 0.964 0.964 0.347 164 4.26e+003 4.25e+003 0.958 0.958 0.345 165 4.32e+003 4.31e+003 0.957 0.957 0.344 166 4.38e+003 4.37e+003 0.949 0.949 0.342 167 4.44e+003 4.43e+003 0.941 0.941 0.339 168 4.5e+003 4.49e+003 0.933 0.933 0.336 169 4.56e+003 4.55e+003 0.925 0.925 0.333 170 4.62e+003 4.61e+003 0.917 0.917 0.33 171 4.68e+003 4.67e+003 0.909 0.909 0.327 172 4.74e+003 4.73e+003 0.909 0.909 0.327 173 4.8e+003 4.79e+003 0.894 0.894 0.322 174 4.86e+003 4.85e+003 0.886 0.886 0.319 175 4.92e+003 4.91e+003 0.862 0.862 0.31 176 4.98e+003 4.97e+003 0.854 0.854 0.307 177 5.04e+003 5.03e+003 0.839 0.839 0.302 178 5.1e+003 5.09e+003 0.822 0.822 0.296 179 5.16e+003 5.15e+003 0.809 0.809 0.291 180 5.22e+003 5.21e+003 0.788 0.788 0.284 181 5.28e+003 5.27e+003 0.782 0.782 0.281 182 5.34e+003 5.33e+003 0.76 0.76 0.274 183 5.4e+003 5.39e+003 0.744 0.744 0.268 184 5.46e+003 5.45e+003 0.729 0.729 0.262 185 5.52e+003 5.51e+003 0.729 0.729 0.262 186 5.58e+003 5.57e+003 0.721 0.721 0.26 187 5.64e+003 5.63e+003 0.713 0.713 0.257 188 5.7e+003 5.69e+003 0.697 0.697 0.251 189 5.76e+003 5.75e+003 0.682 0.682 0.246 190 5.82e+003 5.81e+003 0.674 0.674 0.243 191 5.88e+003 5.87e+003 0.666 0.666 0.24 192 5.94e+003 5.93e+003 0.65 0.65 0.234 193 6.e+003 5.99e+003 0.634 0.634 0.228 194 6.06e+003 6.05e+003 0.627 0.627 0.226 195 6.12e+003 6.11e+003 0.611 0.611 0.22 196 6.18e+003 6.17e+003 0.611 0.611 0.22 197 6.24e+003 6.23e+003 0.603 0.603 0.217 198 6.3e+003 6.29e+003 0.587 0.587 0.211 199 6.36e+003 6.35e+003 0.579 0.579 0.208 200 6.42e+003 6.41e+003 0.572 0.572 0.206 201 6.48e+003 6.47e+003 0.564 0.564 0.203 202 6.54e+003 6.53e+003 0.548 0.548 0.197 203 6.6e+003 6.59e+003 0.548 0.548 0.197 204 6.66e+003 6.65e+003 0.532 0.532 0.192 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ153FH.slg Page 5 205 6.72e+003 6.71e+003 0.524 0.524 0.189 206 6.78e+003 6.77e+003 0.517 0.517 0.186 207 6.84e+003 6.83e+003 0.509 0.509 0.183 208 6.9e+003 6.89e+003 0.509 0.509 0.183 209 6.96e+003 6.95e+003 0.501 0.501 0.18 210 7.02e+003 7.01e+003 0.493 0.493 0.177 211 7.08e+003 7.07e+003 0.477 0.477 0.172 212 7.14e+003 7.13e+003 0.477 0.477 0.172 213 7.2e+003 7.19e+003 0.477 0.477 0.172 214 7.26e+003 7.25e+003 0.462 0.462 0.166 215 7.32e+003 7.31e+003 0.462 0.462 0.166 216 7.38e+003 7.37e+003 0.454 0.454 0.163 217 7.44e+003 7.43e+003 0.446 0.446 0.161 218 7.5e+003 7.49e+003 0.446 0.446 0.161 219 7.56e+003 7.55e+003 0.438 0.438 0.158 220 7.62e+003 7.61e+003 0.438 0.438 0.158 221 7.68e+003 7.67e+003 0.43 0.43 0.155 222 7.74e+003 7.73e+003 0.422 0.422 0.152 223 7.8e+003 7.79e+003 0.422 0.422 0.152 224 7.86e+003 7.85e+003 0.422 0.422 0.152 225 7.92e+003 7.91e+003 0.414 0.414 0.149 226 7.98e+003 7.97e+003 0.407 0.407 0.147 227 8.04e+003 8.03e+003 0.407 0.407 0.147 228 8.1e+003 8.09e+003 0.407 0.407 0.147 229 8.16e+003 8.15e+003 0.399 0.399 0.144 230 8.22e+003 8.21e+003 0.399 0.399 0.144 231 8.28e+003 8.27e+003 0.399 0.399 0.144 232 8.34e+003 8.33e+003 0.391 0.391 0.141 233 8.4e+003 8.39e+003 0.391 0.391 0.141 234 8.46e+003 8.45e+003 0.391 0.391 0.141 235 8.52e+003 8.51e+003 0.391 0.391 0.141 236 8.58e+003 8.57e+003 0.391 0.391 0.141 237 8.64e+003 8.63e+003 0.383 0.383 0.138 238 8.7e+003 8.69e+003 0.383 0.383 0.138 239 8.76e+003 8.75e+003 0.383 0.383 0.138 240 8.82e+003 8.81e+003 0.375 0.375 0.135 241 8.88e+003 8.87e+003 0.367 0.367 0.132 242 8.94e+003 8.93e+003 0.375 0.375 0.135 243 9.e+003 8.99e+003 0.367 0.367 0.132 244 9.06e+003 9.05e+003 0.367 0.367 0.132 245 9.12e+003 9.11e+003 0.359 0.359 0.129 246 9.18e+003 9.17e+003 0.359 0.359 0.129 247 9.24e+003 9.23e+003 0.356 0.356 0.128 248 9.3e+003 9.29e+003 0.337 0.337 0.121 249 9.36e+003 9.35e+003 0.349 0.349 0.126 250 9.42e+003 9.41e+003 0.342 0.342 0.123 251 9.48e+003 9.47e+003 0.342 0.342 0.123 252 9.54e+003 9.53e+003 0.344 0.344 0.124 253 9.6e+003 9.59e+003 0.336 0.336 0.121 254 9.66e+003 9.65e+003 0.336 0.336 0.121 255 9.72e+003 9.71e+003 0.336 0.336 0.121 256 9.78e+003 9.77e+003 0.336 0.336 0.121 257 9.84e+003 9.83e+003 0.328 0.328 0.118 258 9.9e+003 9.89e+003 0.328 0.328 0.118 259 9.96e+003 9.95e+003 0.328 0.328 0.118 260 1.e+004 1.e+004 0.32 0.32 0.115 261 1.01e+004 1.01e+004 0.312 0.312 0.112 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ153FH.slg Page 6 262 1.01e+004 1.01e+004 0.312 0.312 0.112 263 1.02e+004 1.02e+004 0.304 0.304 0.109 264 1.03e+004 1.02e+004 0.304 0.304 0.109 265 1.03e+004 1.03e+004 0.304 0.304 0.109 266 1.04e+004 1.04e+004 0.297 0.297 0.107 267 1.04e+004 1.04e+004 0.297 0.297 0.107 268 1.05e+004 1.05e+004 0.297 0.297 0.107 269 1.06e+004 1.05e+004 0.297 0.297 0.107 270 1.06e+004 1.06e+004 0.289 0.289 0.104 271 1.07e+004 1.07e+004 0.281 0.281 0.101 272 1.07e+004 1.07e+004 0.289 0.289 0.104 273 1.08e+004 1.08e+004 0.289 0.289 0.104 274 1.09e+004 1.08e+004 0.277 0.277 9.97e-002 275 1.09e+004 1.09e+004 0.274 0.274 9.86e-002 276 1.1e+004 1.1e+004 0.28 0.28 0.101 277 1.1e+004 1.1e+004 0.274 0.274 9.86e-002 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ158BFH.slg Page 1 Bouwer and Rice GraphFalling Head Slug Test February 16, 2022 Upper Piedmont Regional MSW Landfill Rougemont, NC Project Number: 1003-81 for Republic Services of North Carolina, LLC. Analysis by BLE PZ-158B Ho is 4.86 feet at 13. Seconds 0 1 2 Adjusted Time (Hours)Head Ratio (Ht/Ho)1.e-002 0.1 1. Bouwer and Rice parameter C = 1.38 ln(Re/Rw) = 2.260068e+000 Analysis starts at time 23. Seconds Analysis ends at time 138 minutes 220 Measurements analyzed from 11 to 230 Hydraulic Conductivity = 1.26e-006 cm/sec Transmissivity = 2.02e-005 ft2/min S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ158BFH.slg Page 1 Falling Head Slug Test Site Name:Upper Piedmont Regional MSW Landfill Location:Rougemont, NC Test Date:February 16, 2022 Client:Republic Services of North Carolina, LLC. Project Number:1003-81 Import File:S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\ Well Label:PZ-158B Aquifer Thickness:8.15 feet Screen Length:5. feet Casing Radius:8.33e-002 feet Effective Radius:0.344 feet Static Water Level:0. feet Water Table to Screen Bottom:8.15 feet Anisotropy Ratio:2. Time Adjustment:13. Seconds Test starts with trial 0 There are 240 time and drawdown measurements Maximum head is 4.86 feet Minimum head is 0. feet Trial Time Adjusted Time Drawdown Head Head Ratio (Seconds)(Seconds)(feet)(feet) 1 13.0.4.86 4.86 1. 2 14.0.96 4.49 4.49 0.924 3 15.1.98 3.32 3.32 0.683 4 16.3.2.88 2.88 0.591 5 17.3.96 2.87 2.87 0.59 6 18.4.98 2.86 2.86 0.588 7 19.6.2.85 2.85 0.587 8 20.6.96 2.85 2.85 0.587 9 21.7.98 2.85 2.85 0.587 10 22.9.2.85 2.85 0.587 11 23.9.96 2.85 2.85 0.587 12 24.11.2.85 2.85 0.587 13 25.12.2.85 2.85 0.587 14 26.13.2.85 2.85 0.585 15 27.14.2.85 2.85 0.587 16 28.15.2.85 2.85 0.587 17 29.16.2.85 2.85 0.585 18 30.17.2.85 2.85 0.585 19 31.18.2.85 2.85 0.585 20 32.19.2.85 2.85 0.585 21 33.20.2.85 2.85 0.585 22 34.21.2.85 2.85 0.585 23 35.22.2.85 2.85 0.585 24 36.23.2.85 2.85 0.585 25 37.24.2.85 2.85 0.585 26 38.25.2.85 2.85 0.585 27 39.26.2.84 2.84 0.584 28 40.27.2.84 2.84 0.584 29 41.28.2.85 2.85 0.585 30 42.29.2.85 2.85 0.586 31 43.30.2.84 2.84 0.584 32 44.31.2.85 2.85 0.585 33 45.32.2.85 2.85 0.586 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ158BFH.slg Page 2 34 46.33.2.84 2.84 0.584 35 47.34.2.85 2.85 0.586 36 48.35.2.84 2.84 0.584 37 49.36.2.85 2.85 0.586 38 50.37.2.85 2.85 0.586 39 51.38.2.85 2.85 0.586 40 52.39.2.85 2.85 0.586 41 53.40.2.84 2.84 0.584 42 54.41.2.84 2.84 0.584 43 55.42.2.84 2.84 0.584 44 56.43.2.84 2.84 0.584 45 57.44.2.84 2.84 0.584 46 58.45.2.84 2.84 0.584 47 59.46.2.84 2.84 0.584 48 60.47.2.84 2.84 0.584 49 70.57.2.84 2.84 0.583 50 80.67.2.84 2.84 0.583 51 90.77.2.84 2.84 0.583 52 100 87.2.84 2.84 0.583 53 110 97.2.83 2.83 0.582 54 120 107 2.83 2.83 0.583 55 130 117 2.84 2.84 0.583 56 140 127 2.83 2.83 0.582 57 150 137 2.84 2.84 0.583 58 160 147 2.83 2.83 0.582 59 170 157 2.84 2.84 0.584 60 180 167 2.83 2.83 0.582 61 190 177 2.83 2.83 0.582 62 200 187 2.83 2.83 0.582 63 210 197 2.83 2.83 0.582 64 220 207 2.83 2.83 0.583 65 230 217 2.83 2.83 0.583 66 240 227 2.83 2.83 0.583 67 250 237 2.83 2.83 0.581 68 260 247 2.83 2.83 0.581 69 270 257 2.83 2.83 0.581 70 280 267 2.84 2.84 0.583 71 290 277 2.83 2.83 0.581 72 300 287 2.83 2.83 0.581 73 310 297 2.82 2.82 0.58 74 320 307 2.83 2.83 0.582 75 330 317 2.83 2.83 0.582 76 340 327 2.83 2.83 0.582 77 350 337 2.82 2.82 0.58 78 360 347 2.82 2.82 0.58 79 370 357 2.82 2.82 0.58 80 380 367 2.82 2.82 0.58 81 390 377 2.82 2.82 0.58 82 400 387 2.82 2.82 0.58 83 410 397 2.82 2.82 0.58 84 420 407 2.81 2.81 0.579 85 430 417 2.81 2.81 0.579 86 440 427 2.82 2.82 0.58 87 450 437 2.81 2.81 0.579 88 460 447 2.82 2.82 0.58 89 470 457 2.81 2.81 0.579 90 480 467 2.81 2.81 0.579 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ158BFH.slg Page 3 91 490 477 2.81 2.81 0.579 92 500 487 2.81 2.81 0.579 93 510 497 2.81 2.81 0.577 94 520 507 2.81 2.81 0.577 95 530 517 2.81 2.81 0.579 96 540 527 2.81 2.81 0.577 97 550 537 2.81 2.81 0.577 98 560 547 2.81 2.81 0.577 99 570 557 2.81 2.81 0.577 100 580 567 2.81 2.81 0.577 101 590 577 2.81 2.81 0.577 102 600 587 2.81 2.81 0.577 103 660 647 2.79 2.79 0.574 104 720 707 2.8 2.8 0.576 105 780 767 2.79 2.79 0.574 106 840 827 2.79 2.79 0.573 107 900 887 2.78 2.78 0.571 108 960 947 2.79 2.79 0.573 109 1.02e+003 1.01e+003 2.78 2.78 0.571 110 1.08e+003 1.07e+003 2.77 2.77 0.569 111 1.14e+003 1.13e+003 2.77 2.77 0.569 112 1.2e+003 1.19e+003 2.76 2.76 0.568 113 1.26e+003 1.25e+003 2.76 2.76 0.567 114 1.32e+003 1.31e+003 2.75 2.75 0.566 115 1.38e+003 1.37e+003 2.75 2.75 0.564 116 1.44e+003 1.43e+003 2.75 2.75 0.566 117 1.5e+003 1.49e+003 2.75 2.75 0.565 118 1.56e+003 1.55e+003 2.74 2.74 0.563 119 1.62e+003 1.61e+003 2.74 2.74 0.563 120 1.68e+003 1.67e+003 2.74 2.74 0.563 121 1.74e+003 1.73e+003 2.73 2.73 0.561 122 1.8e+003 1.79e+003 2.73 2.73 0.561 123 1.86e+003 1.85e+003 2.72 2.72 0.56 124 1.92e+003 1.91e+003 2.71 2.71 0.558 125 1.98e+003 1.97e+003 2.71 2.71 0.558 126 2.04e+003 2.03e+003 2.71 2.71 0.558 127 2.1e+003 2.09e+003 2.7 2.7 0.555 128 2.16e+003 2.15e+003 2.71 2.71 0.557 129 2.22e+003 2.21e+003 2.7 2.7 0.555 130 2.28e+003 2.27e+003 2.69 2.69 0.553 131 2.34e+003 2.33e+003 2.68 2.68 0.552 132 2.4e+003 2.39e+003 2.68 2.68 0.55 133 2.46e+003 2.45e+003 2.68 2.68 0.552 134 2.52e+003 2.51e+003 2.67 2.67 0.549 135 2.58e+003 2.57e+003 2.68 2.68 0.55 136 2.64e+003 2.63e+003 2.67 2.67 0.549 137 2.7e+003 2.69e+003 2.67 2.67 0.549 138 2.76e+003 2.75e+003 2.66 2.66 0.547 139 2.82e+003 2.81e+003 2.66 2.66 0.547 140 2.88e+003 2.87e+003 2.66 2.66 0.547 141 2.94e+003 2.93e+003 2.65 2.65 0.544 142 3.e+003 2.99e+003 2.65 2.65 0.544 143 3.06e+003 3.05e+003 2.65 2.65 0.544 144 3.12e+003 3.11e+003 2.64 2.64 0.542 145 3.18e+003 3.17e+003 2.64 2.64 0.542 146 3.24e+003 3.23e+003 2.64 2.64 0.542 147 3.3e+003 3.29e+003 2.63 2.63 0.541 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ158BFH.slg Page 4 148 3.36e+003 3.35e+003 2.62 2.62 0.539 149 3.42e+003 3.41e+003 2.62 2.62 0.539 150 3.48e+003 3.47e+003 2.62 2.62 0.539 151 3.54e+003 3.53e+003 2.61 2.61 0.537 152 3.6e+003 3.59e+003 2.61 2.61 0.537 153 3.66e+003 3.65e+003 2.61 2.61 0.536 154 3.72e+003 3.71e+003 2.61 2.61 0.536 155 3.78e+003 3.77e+003 2.61 2.61 0.536 156 3.84e+003 3.83e+003 2.6 2.6 0.534 157 3.9e+003 3.89e+003 2.59 2.59 0.532 158 3.96e+003 3.95e+003 2.59 2.59 0.532 159 4.02e+003 4.01e+003 2.59 2.59 0.532 160 4.08e+003 4.07e+003 2.58 2.58 0.531 161 4.14e+003 4.13e+003 2.58 2.58 0.531 162 4.2e+003 4.19e+003 2.58 2.58 0.531 163 4.26e+003 4.25e+003 2.57 2.57 0.528 164 4.32e+003 4.31e+003 2.57 2.57 0.528 165 4.38e+003 4.37e+003 2.56 2.56 0.526 166 4.44e+003 4.43e+003 2.56 2.56 0.526 167 4.5e+003 4.49e+003 2.56 2.56 0.526 168 4.56e+003 4.55e+003 2.55 2.55 0.524 169 4.62e+003 4.61e+003 2.55 2.55 0.524 170 4.68e+003 4.67e+003 2.54 2.54 0.523 171 4.74e+003 4.73e+003 2.54 2.54 0.523 172 4.8e+003 4.79e+003 2.54 2.54 0.523 173 4.86e+003 4.85e+003 2.54 2.54 0.521 174 4.92e+003 4.91e+003 2.54 2.54 0.521 175 4.98e+003 4.97e+003 2.53 2.53 0.52 176 5.04e+003 5.03e+003 2.52 2.52 0.518 177 5.1e+003 5.09e+003 2.52 2.52 0.518 178 5.16e+003 5.15e+003 2.52 2.52 0.518 179 5.22e+003 5.21e+003 2.52 2.52 0.518 180 5.28e+003 5.27e+003 2.51 2.51 0.516 181 5.34e+003 5.33e+003 2.51 2.51 0.516 182 5.4e+003 5.39e+003 2.5 2.5 0.515 183 5.46e+003 5.45e+003 2.5 2.5 0.515 184 5.52e+003 5.51e+003 2.5 2.5 0.515 185 5.58e+003 5.57e+003 2.5 2.5 0.513 186 5.64e+003 5.63e+003 2.5 2.5 0.513 187 5.7e+003 5.69e+003 2.5 2.5 0.513 188 5.76e+003 5.75e+003 2.48 2.48 0.51 189 5.82e+003 5.81e+003 2.48 2.48 0.51 190 5.88e+003 5.87e+003 2.48 2.48 0.51 191 5.94e+003 5.93e+003 2.48 2.48 0.51 192 6.e+003 5.99e+003 2.47 2.47 0.508 193 6.06e+003 6.05e+003 2.47 2.47 0.508 194 6.12e+003 6.11e+003 2.46 2.46 0.507 195 6.18e+003 6.17e+003 2.46 2.46 0.505 196 6.24e+003 6.23e+003 2.46 2.46 0.505 197 6.3e+003 6.29e+003 2.46 2.46 0.505 198 6.36e+003 6.35e+003 2.46 2.46 0.505 199 6.42e+003 6.41e+003 2.46 2.46 0.505 200 6.48e+003 6.47e+003 2.45 2.45 0.504 201 6.54e+003 6.53e+003 2.45 2.45 0.504 202 6.6e+003 6.59e+003 2.44 2.44 0.502 203 6.66e+003 6.65e+003 2.44 2.44 0.502 204 6.72e+003 6.71e+003 2.43 2.43 0.5 S:\Upper Piedmont MSWLF - Person Co. NC\1003-81 DHR Cells 7-10\10 Slug Tests\Current Hydro\Final\UPPZ158BFH.slg Page 5 205 6.78e+003 6.77e+003 2.43 2.43 0.5 206 6.84e+003 6.83e+003 2.43 2.43 0.499 207 6.9e+003 6.89e+003 2.42 2.42 0.498 208 6.96e+003 6.95e+003 2.42 2.42 0.497 209 7.02e+003 7.01e+003 2.42 2.42 0.497 210 7.08e+003 7.07e+003 2.42 2.42 0.497 211 7.14e+003 7.13e+003 2.41 2.41 0.495 212 7.2e+003 7.19e+003 2.4 2.4 0.494 213 7.26e+003 7.25e+003 2.4 2.4 0.494 214 7.32e+003 7.31e+003 2.41 2.41 0.495 215 7.38e+003 7.37e+003 2.4 2.4 0.492 216 7.44e+003 7.43e+003 2.4 2.4 0.493 217 7.5e+003 7.49e+003 2.39 2.39 0.492 218 7.56e+003 7.55e+003 2.39 2.39 0.491 219 7.62e+003 7.61e+003 2.39 2.39 0.491 220 7.68e+003 7.67e+003 2.39 2.39 0.491 221 7.74e+003 7.73e+003 2.39 2.39 0.491 222 7.8e+003 7.79e+003 2.38 2.38 0.489 223 7.86e+003 7.85e+003 2.38 2.38 0.489 224 7.92e+003 7.91e+003 2.37 2.37 0.487 225 7.98e+003 7.97e+003 2.37 2.37 0.487 226 8.04e+003 8.03e+003 2.37 2.37 0.487 227 8.1e+003 8.09e+003 2.36 2.36 0.486 228 8.16e+003 8.15e+003 2.36 2.36 0.486 229 8.22e+003 8.21e+003 2.36 2.36 0.484 230 8.28e+003 8.27e+003 2.36 2.36 0.484 231 8.34e+003 8.33e+003 2.36 2.36 0.484 232 8.4e+003 8.39e+003 2.35 2.35 0.483 233 8.46e+003 8.45e+003 2.35 2.35 0.483 234 8.52e+003 8.51e+003 2.34 2.34 0.481 235 8.58e+003 8.57e+003 2.34 2.34 0.481 236 8.64e+003 8.63e+003 2.34 2.34 0.481 237 8.7e+003 8.69e+003 2.33 2.33 0.479 238 8.76e+003 8.75e+003 2.32 2.32 0.478 239 8.82e+003 8.81e+003 2.32 2.32 0.478 240 8.88e+003 8.87e+003 2.33 2.33 0.478 APPENDIX G Soil Laboratory Test Procedures APPENDIX G Soil Laboratory Test Procedures MOISTURE CONTENT AND UNIT WEIGHT An undisturbed sample is trimmed in the laboratory into a right circular cylinder approximately three to six inches long. The dimensions and weight of the specimen are determined and the total unit weight calculated. Moisture contents are determined from representative portions of the specimen. The soil is dried to a constant weight in an oven at 100 degrees C and the loss of moisture during the drying process is measured. From this data, the moisture content and dry unit weight are computed. ATTERBERG LIMITS The Atterberg Limits Tests, Liquid Limit (LL), and Plastic Limit (PL), are performed to aid in the classification of soils and to determine the plasticity and volume change characteristics of the materials. The Liquid Limit is the minimum moisture content at which a soil will flow as a heavy viscous fluid. The Plastic Limit is the minimum moisture content at which the solid behaves as a plastic material. The Plasticity Index (PI) is the numeric difference of Liquid Limit and the Plastic Limit and indicated the range of moisture content over which a soil remains plastic. These tests are performed in accordance with ASTM D 4318. PARTICLE SIZE DISTRIBUTION The distribution of soils coarser than the No. 200 (75-um) sieve is determined by passing a representative specimen through a standard set of nested sieves. The weight of material retained on each sieve is determined and the percentage retained (or passing) is calculated. A specimen may be washed through only the No. 200 sieve, if the full range of particle sizes is not required. The percentage of material passing the No. 200 sieve is reported. The distribution of materials finer than No. 200 sieve is determined by use of the hydrometer. The particle sizes and distribution are computed from the time rate of settlement of the different size particles while suspended in water. These tests are performed in accordance with ASTM D 421, D 422, and D 1140. HYDRAULIC CONDUCTIVITY The ease with which water flows through a soil is characterized by its hydraulic conductivity. Two general test methods are employed depending on the soil type. The Constant Head method is used for coarse-grained materials (sands and gravels). The sample is confined in permeameter chamber while water is allowed to flow through it from a constant head level. The quantity of water flowing through the specimen in a given time period is used to calculate the hydraulic conductivity. See ASTM D 2434 for a complete description of this test. Fine-grained materials (silts and clays) require the use of a Flexible Wall Permeameter. The sample is prepared in a similar manner as in the triaxial compression test. It is encased in a rubber membrane and place inside a permeameter chamber. The specimen is back-pressure saturated and allowed to consolidate under a specified effective stress. Water is then forced through the specimen under a controlled hydraulic gradient. The quantity of water flowing into the sample in a given time period is used to calculate the hydraulic conductivity. This test is performed in general accordance wit ASTM D 5084. COMPACTION Bulk samples of potential borrow soils from the project site were collected and transported to the laboratory for compaction testing. A standard Proctor compaction test (ASTM D 698) was performed on each sample to determine compaction characteristics, including the maximum dry density and optimum moisture content. Test results are presented on the attached Compaction Test sheet. CONSOLIDATION A single section of the undisturbed sample was extruded from its sampling tube for consolidation testing. The sample was then trimmed into a disc 2.4 inches in diameter and 1 inch thick. The disc was confined in a stainless steel ring and sandwiched between porous plates. It was then subjected to incrementally increasing vertical loads and the resulting deformations measured with a micrometer dial gauge. The test results are presented in the form of a pressure versus percent strain curve on the accompanying Consolidation Test sheet. TRIAXIAL SHEAR Multi-stage consolidated undrained triaxial compression tests were conducted on relatively undisturbed soil samples. Each sample was trimmed and the initial moisture content and unit weight was determined. The trimmed sample was placed into a waterproof membrane and loaded into the test cell. The sample was subjected to an assigned confining pressure and allowed to consolidate. The sample was then subjected to an axial compressive load, which was gradually increased until incipient failure, at which point the confining pressure was increased and the process repeated. Pore pressures were measured during the test to permit determination of the total stress and effective stress parameters. The test results are used to estimate the strength parameters of the soil (angle of internal friction and cohesion). The test results are presented in the form of Stress-Strain Curves and Mohr Diagrams on the accompanying Triaxial Shear Test sheets. APPENDIX H Soil Laboratory Test Results Tested By: JM Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Light brown & light grey fi. sandy silty CLAY #10 #20 #40 #60 #100 #200 100.0 98.6 94.6 90.2 85.6 74.0 21 27 6 0.2440 0.1424 0.0443 0.0310 0.0100 0.0032 0.0017 25.78 1.31 CL-ML A-4(3) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 8.0-10.0 Sample Number: PZ-140 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.0 0.0 5.4 20.6 52.8 21.26 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Grey silty clayey fi.-co. SAND 3/4 1/2 3/8 #4 #10 #20 #40 #60 #100 #200 100.0 94.7 91.9 80.8 59.1 43.6 33.6 28.0 24.0 20.3 17 24 7 8.0638 5.8467 2.0763 1.2593 0.3079 0.0160 0.0070 295.65 6.50 SC-SM A-2-4(0) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 3.5-5.0 Sample Number: PZ-125 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 19.2 21.7 25.5 13.3 11.6 8.76 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Tan clayey fi.-med. SAND 3/4 1/2 3/8 #4 #10 #20 #40 #60 #100 #200 100.0 91.8 90.1 81.9 73.9 63.5 53.6 46.7 39.7 31.3 17 30 13 9.2917 5.9659 0.6644 0.3222 0.0670 0.0118 0.0052 126.96 1.29 SC A-2-6(0) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 8.5-10.0 Sample Number: PZ-138 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 18.1 8.0 20.3 22.3 21.6 9.76 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Brown fi. sandy CLAY #10 #20 #40 #60 #100 #200 100.0 99.8 99.4 98.2 93.8 83.4 25 53 28 0.1135 0.0827 0.0158 0.0103 0.0036 CH A-7-6(25) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 8.5-15.0 Sample Number: PZ-140 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.0 0.0 0.6 16.0 47.3 36.16 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Tested By: JM Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Yellowish brown & black fi. sandy SILT #10 #20 #40 #60 #100 #200 100.0 97.4 93.2 89.6 86.4 76.2 25 29 4 0.2665 0.1275 0.0453 0.0335 0.0137 0.0052 0.0036 12.46 1.14 ML A-4(2) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 23.0-24.5 Sample Number: PZ-140 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.0 0.0 6.8 17.0 62.0 14.26 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Reddish brown fi. sandy CLAY 3/8 #4 #10 #20 #40 #60 #100 #200 100.0 99.2 98.8 95.9 90.7 87.4 84.2 80.6 28 56 28 0.3818 0.1721 0.0068 0.0039 CH A-7-6(25) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 1.0-2.5 Sample Number: PZ-147 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.8 0.4 8.1 10.1 26.5 54.16 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Tan fi.-med. sandy SILT #10 #20 #40 #60 #100 #200 100.0 90.6 80.4 74.0 69.0 63.2 28 38 10 0.8137 0.5806 0.0498 0.0220 0.0059 0.0037 0.0030 16.61 0.23 ML A-4(5) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 13.5-15.0 Sample Number: PZ-147 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.0 0.0 19.6 17.2 38.3 24.96 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Tan clayey fi.-med. SAND 1/2 3/8 #4 #10 #20 #40 #60 #100 #200 100.0 94.8 87.7 74.9 64.7 56.1 50.5 46.2 41.8 24 33 9 6.0633 3.8381 0.5832 0.2367 0.0128 0.0051 0.0037 155.78 0.08 SC A-4(1) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 28.5-30.0 Sample Number: PZ-147 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 12.3 12.8 18.8 14.3 27.1 14.76 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Tested By: JM Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Yellowish brown SILT w/ some fi. sand #10 #20 #40 #60 #100 #200 100.0 100.0 99.8 99.0 97.4 94.2 29 44 15 0.0501 0.0358 0.0090 0.0065 0.0025 ML A-7-6(17) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 3.0-5.0 Sample Number: PZ-148 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.0 0.0 0.2 5.6 51.9 42.36 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Tested By: JM Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Yellowish brown fi. sandy SILT #10 #20 #40 #60 #100 #200 100.0 100.0 99.4 96.8 93.2 86.8 32 46 14 0.1004 0.0660 0.0108 0.0075 0.0041 ML A-7-5(15) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 13.0-15.0 Sample Number: PZ-148 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.0 0.0 0.6 12.6 50.2 36.66 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Tested By: JM Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Light brown, yellow & black fi. sandy elastic SILT 3/8 #4 #10 #20 #40 #60 #100 #200 100.0 100.0 99.4 99.2 97.4 94.4 90.4 84.7 32 54 22 0.1428 0.0787 0.0096 0.0067 0.0042 0.0024 0.0018 5.41 1.02 MH A-7-5(22) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 23.0-25.0 Sample Number: PZ-148 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.0 0.6 2.0 12.7 47.5 37.26 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Light grey clayey fi.-med. SAND 3/8 #4 #10 #20 #40 #60 #100 #200 100.0 91.4 81.8 66.9 55.3 48.4 43.4 38.0 19 32 13 4.1663 2.5774 0.5732 0.2860 0.0255 0.0039 0.0019 299.88 0.59 SC A-6(1) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 8.5-10.0 Sample Number: PZ-151 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 8.6 9.6 26.5 17.3 21.0 17.06 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Tan, light grey fi. sandy SILT #10 #20 #40 #60 #100 #200 100.0 99.0 97.6 95.2 92.0 87.2 29 39 10 0.1036 0.0638 0.0125 0.0090 0.0054 0.0038 0.0033 3.72 0.69 ML A-4(10) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 3.5-5.0 Sample Number: PZ-155 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.0 0.0 2.4 10.4 60.6 26.66 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Grey, brown clayey fi.-co. SAND 1.0 3/4 1/2 3/8 #4 #10 #20 #40 #60 #100 #200 100.0 93.0 89.4 79.4 69.6 59.2 51.7 45.7 41.9 38.8 35.4 19 32 13 13.0360 11.0579 2.1404 0.6953 0.0490 0.0068 0.0042 505.46 0.27 SC A-2-6(1) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 13.5-15.0 Sample Number: PZ-156 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 7.0 23.4 10.4 13.5 10.3 24.2 11.26 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Tested By: JM Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Light brown fi. sandy silty CLAY #10 #40 #60 #100 #200 100.0 97.6 87.8 73.2 54.2 22 27 5 0.2737 0.2254 0.0893 0.0676 0.0432 0.0183 0.0085 10.54 2.46 CL-ML A-4(1) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 3.0-5.0 Sample Number: PZ-157 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.0 0.0 2.4 43.4 47.3 6.96 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Grey clayey fi.-co. SAND 3/4 1/2 3/8 #4 #10 #20 #40 #60 #100 #200 100.0 88.5 86.1 82.5 74.3 64.8 55.4 49.3 44.9 40.3 19 30 11 13.7179 7.2749 0.5952 0.2666 0.0138 0.0043 0.0020 298.52 0.16 SC A-6(1) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 2.0-8.0 Sample Number: PZ-159 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 17.5 8.2 18.9 15.1 23.5 16.86 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Brown CLAY w/sand #10 #20 #40 #60 #100 #200 100.0 97.8 96.0 94.6 93.4 91.2 26 45 19 0.0609 0.0341 0.0082 0.0059 0.0025 CL A-7-6(19) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 2.0-7.0 Sample Number: PZ-160 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 0.0 0.0 4.0 4.8 46.5 44.76 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Tested By: JM Bunnell Lammons Engineering, Inc. Greenville, SC (no specification provided) PL=LL=PI= D90=D85=D60= D50=D30=D15= D10=Cu=Cc= USCS=AASHTO= * Grey & brown fi.-med. sandy CLAY 3/8 #4 #10 #20 #40 #60 #100 #200 100.0 95.1 90.5 87.9 86.3 85.0 83.6 81.2 27 47 20 1.7636 0.2453 0.0090 0.0059 0.0020 CL A-7-6(17) Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Material Description Atterberg Limits Coefficients Classification Remarks Source of Sample: Boring Depth: 3.0-4.5 Sample Number: PZ-160 Date: Client: Project: Project No:Figure SIEVE PERCENT SPEC.*PASS? SIZE FINER PERCENT (X=NO)PERCENT FINER0 10 20 30 40 50 60 70 80 90 100 GRAIN SIZE - mm. 0.0010.010.1110100 % +3"Coarse % Gravel Fine Coarse Medium % Sand Fine Silt % Fines Clay 0.0 0.0 4.9 4.6 4.2 5.1 34.8 46.46 in.3 in.2 in.1½ in.1 in.¾ in.½ in.3/8 in.#4#10#20#30#40#60#100#140#200Particle Size Distribution Report ASTM D6913/D422 Upper Piedmont MSW Landfill Person Co., NC BLE Project Number P21-1003-81 Min Max Min Max <0.00625 0.03 0.77 <0.00625 0.03 0.77 D50 mm 1.2593 0.00625 to 0.025 0.04 0.87 D50 mm 0.2 USE →0.00625 to 0.025 0.04 0.87 0.025 to 0.05 0.31 0.91 0.025 to 0.05 0.31 0.91 D50 cm 0.12593 0.05 to 0.1 0.58 0.94 D50 cm 0.02000 0.05 to 0.1 0.58 0.94 USE →>0.1 0.52 0.95 >0.1 0.52 0.95 Natural log of D50 -2.072 Natural log of D50 -3.912 Max Calculation 0.323734464 Max Calculation 0.358103211 Total Porosity (Ø)0.341 Total Porosity (Ø)0.412 Min Calculation 0.177202022 Min Calculation 0.016464515 Average Øe 0.250 Average Øe 0.187 Min Max Min Max USE →<0.00625 0.03 0.77 USE →<0.00625 0.03 0.77 D50 mm 0.0103 0.00625 to 0.025 0.04 0.87 D50 mm 0.0335 0.00625 to 0.025 0.04 0.87 0.025 to 0.05 0.31 0.91 0.025 to 0.05 0.31 0.91 D50 cm 0.00103 0.05 to 0.1 0.58 0.94 D50 cm 0.00335 0.05 to 0.1 0.58 0.94 >0.1 0.52 0.95 >0.1 0.52 0.95 Natural log of D50 -6.878 Natural log of D50 -5.699 Max Calculation 0.404874135 Max Calculation 0.369910776 Total Porosity (Ø)0.526 Total Porosity (Ø)0.480 Min Calculation 0.015774317 Min Calculation 0.014412108 Average Øe 0.210 Average Øe 0.192 Min Max Min Max USE →<0.00625 0.03 0.77 USE →<0.00625 0.03 0.77 D50 mm 0.0039 0.00625 to 0.025 0.04 0.87 D50 mm 0.022 0.00625 to 0.025 0.04 0.87 0.025 to 0.05 0.31 0.91 0.025 to 0.05 0.31 0.91 D50 cm 0.00039 0.05 to 0.1 0.58 0.94 D50 cm 0.00220 0.05 to 0.1 0.58 0.94 >0.1 0.52 0.95 >0.1 0.52 0.95 Natural log of D50 -7.849 Natural log of D50 -6.119 Max Calculation 0.43366439 Max Calculation 0.382376587 Total Porosity (Ø)0.563 Total Porosity (Ø)0.497 Min Calculation 0.016896015 Min Calculation 0.014897789 Average Øe 0.225 Average Øe 0.199 Min Max Min Max <0.00625 0.03 0.77 USE →<0.00625 0.03 0.77 D50 mm 0.2367 USE →0.00625 to 0.025 0.04 0.87 D50 mm 0.0065 0.00625 to 0.025 0.04 0.87 0.025 to 0.05 0.31 0.91 0.025 to 0.05 0.31 0.91 D50 cm 0.02367 0.05 to 0.1 0.58 0.94 D50 cm 0.00065 0.05 to 0.1 0.58 0.94 >0.1 0.52 0.95 >0.1 0.52 0.95 Natural log of D50 -3.744 Natural log of D50 -7.339 Max Calculation 0.352460102 Max Calculation 0.418520965 Total Porosity (Ø)0.405 Total Porosity (Ø)0.544 Min Calculation 0.016205062 Min Calculation 0.016306012 Average Øe 0.184 Average Øe 0.217 Min Max Min Max USE →<0.00625 0.03 0.77 USE →<0.00625 0.03 0.77 D50 mm 0.0075 0.00625 to 0.025 0.04 0.87 D50 mm 0.0067 0.00625 to 0.025 0.04 0.87 0.025 to 0.05 0.31 0.91 0.025 to 0.05 0.31 0.91 D50 cm 0.00075 0.05 to 0.1 0.58 0.94 D50 cm 0.00067 0.05 to 0.1 0.58 0.94 >0.1 0.52 0.95 >0.1 0.52 0.95 Natural log of D50 -7.195 Natural log of D50 -7.308 Max Calculation 0.41427874 Max Calculation 0.417622563 Total Porosity (Ø)0.538 Total Porosity (Ø)0.542 Min Calculation 0.01614073 Min Calculation 0.016271009 Average Øe 0.215 Average Øe 0.217 Min Max Min Max <0.00625 0.03 0.77 USE →<0.00625 0.03 0.77 D50 mm 0.286 0.00625 to 0.025 0.04 0.87 D50 mm 0.009 0.00625 to 0.025 0.04 0.87 USE →0.025 to 0.05 0.31 0.91 0.025 to 0.05 0.31 0.91 D50 cm 0.02860 0.05 to 0.1 0.58 0.94 D50 cm 0.00090 0.05 to 0.1 0.58 0.94 >0.1 0.52 0.95 >0.1 0.52 0.95 Natural log of D50 -3.554 Natural log of D50 -7.013 Max Calculation 0.362036602 Max Calculation 0.408873818 Total Porosity (Ø)0.398 Total Porosity (Ø)0.531 Min Calculation 0.12333115 Min Calculation 0.015930149 Average Øe 0.243 Average Øe 0.212 Effective Porosity (Øe)Effective Porosity (Øe) Mean Particle Diameter cm Range of Ratio: Øe / Ø Mean Particle Diameter cm Range of Ratio: Øe / Ø Calculation for Effective Porosity: PZ-148 (13.0' - 15.0') Mean Particle Diameter cm Range of Ratio: Øe / Ø Total Porosity Calc Effective Porosity (Øe) Total Porosity Calc Total Porosity Calc Calculation for Effective Porosity: PZ-151 (8.5' - 10.0')Calculation for Effective Porosity: PZ-155 (3.5' - 5.0') Effective Porosity (Øe) Range of Ratio: Øe / Ø Total Porosity Calc Effective Porosity (Øe) Calculation for Effective Porosity: PZ-147 (13.5' - 15.5') Mean Particle Diameter cm Range of Ratio: Øe / Ø Total Porosity Calc Effective Porosity (Øe) Calculation for Effective Porosity: PZ-148 (23.0' - 25.0') Mean Particle Diameter cm Range of Ratio: Øe / Ø Total Porosity Calc Calculation for Effective Porosity: PZ-138 (8.5' - 10.0') Mean Particle Diameter cm Range of Ratio: Øe / Ø Total Porosity Calc Range of Ratio: Øe / ØMean Particle Diameter cm Effective Porosity (Øe) Calculation for Effective Porosity: PZ-140 (23.0' - 24.5') Total Porosity Calc Effective Porosity (Øe) Calculation for Effective Porosity: PZ-148 (3.0' - 5.0') Mean Particle Diameter cm Effective Porosity (Øe) Calculation for Effective Porosity: PZ-125 (3.5' - 5.0') Mean Particle Diameter cm Range of Ratio: Øe / Ø Total Porosity Calc Effective Porosity (Øe) Mean Particle Diameter cm Range of Ratio: Øe / Ø Total Porosity Calc Effective Porosity (Øe) Calculation for Effective Porosity: PZ-147 (1.0' - 2.5') Mean Particle Diameter cm Range of Ratio: Øe / Ø Total Porosity Calc Calculation for Effective Porosity: PZ-140 (8.0' - 10.0') Calculation for Effective Porosity: PZ-147 (28.5' - 30.0') Mean Particle Diameter cm Range of Ratio: Øe / Ø Total Porosity Calc Effective Porosity (Øe) UPRLF-DHR Cells 7-10.xlsx D50 Calculation Prepared By: RLB Checked By: ZJD Upper Piedmont MSW Landfill Person Co., NC BLE Project Number P21-1003-81 Min Max Min Max <0.00625 0.03 0.77 <0.00625 0.03 0.77 D50 mm 0.6953 0.00625 to 0.025 0.04 0.87 D50 mm 0.0676 USE →0.00625 to 0.025 0.04 0.87 0.025 to 0.05 0.31 0.91 0.025 to 0.05 0.31 0.91 D50 cm 0.06953 USE →0.05 to 0.1 0.58 0.94 D50 cm 0.00676 0.05 to 0.1 0.58 0.94 >0.1 0.52 0.95 >0.1 0.52 0.95 Natural log of D50 -2.666 Natural log of D50 -4.997 Max Calculation 0.34182243 Max Calculation 0.394435551 Total Porosity (Ø)0.364 Total Porosity (Ø)0.453 Min Calculation 0.210911712 Min Calculation 0.018134968 Average Øe 0.276 Average Øe 0.206 Min Max USE →<0.00625 0.03 0.77 D50 mm 0.0059 0.00625 to 0.025 0.04 0.87 0.025 to 0.05 0.31 0.91 D50 cm 0.00059 0.05 to 0.1 0.58 0.94 >0.1 0.52 0.95 Natural log of D50 -7.435 Max Calculation 0.421392078 Total Porosity (Ø)0.547 Min Calculation 0.016417873 Average Øe 0.219 Effective Porosity (Øe) Calculation for Effective Porosity: PZ-160 (3.0' - 4.5') Mean Particle Diameter cm Range of Ratio: Øe / Ø Total Porosity Calc Effective Porosity (Øe)Effective Porosity (Øe) Calculation for Effective Porosity: PZ-157 (3.0' - 5.0') Mean Particle Diameter cm Range of Ratio: Øe / Ø Total Porosity Calc Calculation for Effective Porosity: PZ-156 (13.5' - 15.0') Mean Particle Diameter cm Range of Ratio: Øe / Ø Total Porosity Calc UPRLF-DHR Cells 7-10.xlsx D50 Calculation Prepared By: RLB Checked By: ZJD Tested By: JM Liquid and Plastic Limits Test Report (ASTM D4318)PLASTICITY INDEX0 10 20 30 40 50 60 LIQUID LIMIT 0 10 20 30 40 50 60 70 80 90 100 110 CL-ML CL or OL CH or O H ML or OL MH or OH Dashed line indicates the approximate upper limit boundary for natural soils 47 SOIL DATA SYMBOL SOURCE NATURAL USCSSAMPLEDEPTHWATERPLASTICLIQUIDPLASTICITY NO.CONTENT LIMIT LIMIT INDEX (%)(%)(%)(%) Bunnell Lammons Engineering, Inc. Greenville, SC Client: Project: Project No.:Figure Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Boring PZ-140 8.0-10.0 18.4 21 27 6 CL-ML Boring PZ-125 3.5-5.0 11.5 17 24 7 SC-SM Boring PZ-138 8.5-10.0 8.4 17 30 13 SC Boring PZ-140 8.5-15.0 25 53 28 CH Boring PZ-140 23.0-24.5 19.6 25 29 4 ML Tested By: JM Liquid and Plastic Limits Test Report (ASTM D4318)PLASTICITY INDEX0 10 20 30 40 50 60 LIQUID LIMIT 0 10 20 30 40 50 60 70 80 90 100 110 CL-ML CL or OL CH or O H ML or OL MH or OH Dashed line indicates the approximate upper limit boundary for natural soils 47 SOIL DATA SYMBOL SOURCE NATURAL USCSSAMPLEDEPTHWATERPLASTICLIQUIDPLASTICITY NO.CONTENT LIMIT LIMIT INDEX (%)(%)(%)(%) Bunnell Lammons Engineering, Inc. Greenville, SC Client: Project: Project No.:Figure Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Boring PZ-147 1.0-2.5 25.5 28 56 28 CH Boring PZ-147 13.5-15.0 17.2 28 38 10 ML Boring PZ-147 28.5-30.0 9.3 24 33 9 SC Boring PZ-148 3.0-5.0 36.2 29 44 15 ML Boring PZ-148 13.0-15.0 39.5 32 46 14 ML Tested By: JM Liquid and Plastic Limits Test Report (ASTM D4318)PLASTICITY INDEX0 10 20 30 40 50 60 LIQUID LIMIT 0 10 20 30 40 50 60 70 80 90 100 110 CL-ML CL or OL CH or O H ML or OL MH or OH Dashed line indicates the approximate upper limit boundary for natural soils 47 SOIL DATA SYMBOL SOURCE NATURAL USCSSAMPLEDEPTHWATERPLASTICLIQUIDPLASTICITY NO.CONTENT LIMIT LIMIT INDEX (%)(%)(%)(%) Bunnell Lammons Engineering, Inc. Greenville, SC Client: Project: Project No.:Figure Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Boring PZ-148 23.0-25.0 47.9 32 54 22 MH Boring PZ-151 8.5-10.0 9.3 19 32 13 SC Boring PZ-155 3.5-5.0 31.5 29 39 10 ML Boring PZ-156 13.5-15.0 11.9 19 32 13 SC Boring PZ-157 3.0-5.0 11.1 22 27 5 CL-ML Tested By: JM Liquid and Plastic Limits Test Report (ASTM D4318)PLASTICITY INDEX0 10 20 30 40 50 60 LIQUID LIMIT 0 10 20 30 40 50 60 70 80 90 100 110 CL-ML CL or OL CH or O H ML or OL MH or OH Dashed line indicates the approximate upper limit boundary for natural soils 47 SOIL DATA SYMBOL SOURCE NATURAL USCSSAMPLEDEPTHWATERPLASTICLIQUIDPLASTICITY NO.CONTENT LIMIT LIMIT INDEX (%)(%)(%)(%) Bunnell Lammons Engineering, Inc. Greenville, SC Client: Project: Project No.:Figure Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 1003-81 Boring PZ-159 2.0-8.0 19 30 11 SC Boring PZ-160 2.0-7.0 26 45 19 CL Boring PZ-160 3.0-4.5 23.1 27 47 20 CL UPRLF CELLS 7 - 10 SAMPLE NO. DEPTH (Ft) DRY WEIGHT (g)MOISTURE CONTENT (%) PZ-140 8.0 10.0 170.6 18.4 PZ-140 23.0 24.5 174.7 19.6 PZ-148 3.0 5.0 119.7 36.2 PZ-148 13.0 15.0 99.2 39.5 PZ-148 23.0 25.0 99.9 47.9 PZ-157 3.0 5.0 156.9 11.1 PZ-160 3.0 4.5 144.9 23.1 SAMPLE NO. DEPTH (Ft) WET DENSITY (PCF) DRY DENSITY (PCF) LENGTH (IN)6.023 DIA. (IN)2.878 WT. (LB)2.95 LENGTH (IN)5.760 DIA. (IN)2.880 WT. (LB)2.78 LENGTH (IN)5.783 DIA. (IN)2.880 WT. (LB)2.42 LENGTH (IN)5.766 DIA. (IN)2.879 WT. (LB)2.36 LENGTH (IN)6.000 DIA. (IN)2.856 WT. (LB)2.35 LENGTH (IN)5.302 DIA. (IN)2.883 WT. (LB)2.88 LENGTH (IN)5.293 DIA. (IN)2.881 WT. (LB)2.49 TESTED BY: JOHN MATHEW CHECKED BY: PAUL YARBER III DATE: 5/19/2021 PZ-157 3.0 5.0 144.0 129.6 PZ-160 3.0 4.5 124.5 101.1 PZ-148 13.0 15.0 108.8 78.0 PZ-148 23.0 25.0 105.9 71.5 PZ-140 23.0 24.5 128.1 107.1 PZ-148 3.0 5.0 111.0 81.5 SAMPLE PROPERTIES PZ-140 8.0 10.0 130.0 109.8 LABORATORY UNIT WEIGHT DETERMINATION 163.0 138.4 147.8 174.3 178.4 J21-1003-81 LABORATORY MOISTURE CONTENT DETERMINATION (ASTM D2216) WET WEIGHT (g) 202.0 209.0 COMPACTION TEST REPORT Dry density, pcf90 95 100 105 110 115 Water content, % 5 10 15 20 25 30 35 ZAV for Sp.G. = 2.70 Test specification:ASTM D 698-12 Method A Standard 8.5-15.0 CH A-7-6(25)53 28 0.0 83.4 Brown fi. sandy CLAY 1003-81 Republic Services of North Carolina, LLC Elev/Classification Nat.Sp.G.LL PI % >% < Depth USCS AASHTO Moist.#4 No.200 TEST RESULTS MATERIAL DESCRIPTION Project No.Client:Remarks: Project: Source of Sample: Boring Sample Number: PZ-140 Bunnell Lammons Engineering, Inc. Greenville, SC Figure Maximum dry density = 101.9 pcf Optimum moisture = 18.0 % Upper Piedmont Regional Landfill Cells 7 - 10 COMPACTION TEST REPORT Dry density, pcf105 110 115 120 125 130 Water content, % 0 5 10 15 20 25 30 ZAV for Sp.G. = 2.70 Test specification:ASTM D 698-12 Method A Standard 2.0-8.0 SC A-6(1)30 11 17.5 40.3 Grey clayey fi.-co. SAND 1003-81 Republic Services of North Carolina, LLC Elev/Classification Nat.Sp.G.LL PI % >% < Depth USCS AASHTO Moist.#4 No.200 TEST RESULTS MATERIAL DESCRIPTION Project No.Client:Remarks: Project: Source of Sample: Boring Sample Number: PZ-159 Bunnell Lammons Engineering, Inc. Greenville, SC Figure Maximum dry density = 121.4 pcf Optimum moisture = 11.9 % Upper Piedmont Regional Landfill Cells 7 - 10 COMPACTION TEST REPORT Dry density, pcf90 95 100 105 110 115 Water content, % 5 10 15 20 25 30 35 ZAV for Sp.G. = 2.70 Test specification:ASTM D 698-12 Method A Standard 2.0-7.0 CL A-7-6(19)45 19 0.0 91.2 Brown CLAY w/sand 1003-81 Republic Services of North Carolina, LLC Elev/Classification Nat.Sp.G.LL PI % >% < Depth USCS AASHTO Moist.#4 No.200 TEST RESULTS MATERIAL DESCRIPTION Project No.Client:Remarks: Project: Source of Sample: Boring Sample Number: PZ-160 Bunnell Lammons Engineering, Inc. Greenville, SC Figure Maximum dry density = 103.4 pcf Optimum moisture = 19.5 % Upper Piedmont Regional Landfill Cells 7 - 10 HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) PROJECT:TESTED BY:JOHN MATHEW PROJECT NO.:CHECKED BY:PAUL YARBER DATE RECEIVED: SAMPLE NO. SAMPLE LOCATION:8.0-10.0' TYPE SAMPLE DESCRIPTION:LIGHT BROWN & LIGHT GREY FI. SAND SILTY CLAY SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 7.554 7.534 Sample Diameter 7.267 7.247 Length/Diameter Ratio 1.04 Moisture Content (%)WW= 202.0 DW= 170.6 18.4 WW= 148.1 DW= 123.9 19.5 Sample Wet Weight (grams) Wet Density (pcf) 130.0 131.2 Dry Density (pcf) 109.8 109.8 Saturation (%)ASSUMED SG= 2.7 93 99 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi)70 Influent Pressure (psi)60 Effluent Pressure (psi) 60 B-Value 0.96 Reset Date Clock Time Elapsed Time HAOUT HAIN Temp Gradient K Temp K20°C (Y/N) (cm) (cm) ºC (cm/sec) Correction (cm/sec) Y 7.6 1.77 22.0 10 0:03:25 6.5 1.82 22.0 8 4.7E-07 0.953 4.5E-07 0:03:46 6.4 1.82 22.0 8 4.7E-07 0.953 4.5E-07 0:04:09 6.3 1.82 22.0 8 4.7E-07 0.953 4.4E-07 0:04:31 6.2 1.83 22.0 8 4.7E-07 0.953 4.4E-07 HYDRAULIC CONDUCTIVITY (K20°C)4.4E-07 cm/sec 4-29-21 10:48:54 4-29-21 10:49:16 4-29-21 10:44:45 4-29-21 10:48:10 4-29-21 10:48:31 2.974 2.966 2.861 2.853 652.2 653.2 UPPER PIEDMONT REG. LANDFILL CELLS 7 - 10 J21-1003-81 4-21-21 PZ-140 UNDISTURBED HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) PROJECT:TESTED BY:JOHN MATHEW PROJECT NO.:CHECKED BY:PAUL YARBER DATE RECEIVED: SAMPLE NO. SAMPLE LOCATION:23.0-24.5 TYPE SAMPLE DESCRIPTION:YELLOWISH BROWN & BLACK FI. SANDY SILT SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 7.468 7.617 Sample Diameter 7.277 7.295 Length/Diameter Ratio 1.03 Moisture Content (%)WW= 209.0 DW= 174.7 19.6 WW= 199.9 DW= 163.1 22.6 Sample Wet Weight (grams) Wet Density (pcf) 129.4 127.8 Dry Density (pcf) 108.2 104.3 Saturation (%)ASSUMED SG= 2.7 95 99 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi)75 Influent Pressure (psi)60 Effluent Pressure (psi) 60 B-Value 0.96 Reset Date Clock Time Elapsed Time HAOUT HAIN Temp Gradient K Temp K20°C (Y/N) (cm) (cm) ºC (cm/sec) Correction (cm/sec) Y 4.7 1.89 22.0 5 0:00:06 4.0 1.92 22.0 4 2.2E-05 0.953 2.1E-05 0:00:12 3.5 1.94 22.0 3 2.1E-05 0.953 2.0E-05 0:00:20 3.0 1.96 22.0 2 2.2E-05 0.953 2.1E-05 0:00:33 2.5 1.98 22.0 1 2.2E-05 0.953 2.1E-05 HYDRAULIC CONDUCTIVITY (K20°C)2.1E-05 cm/sec 4-29-21 1:35:33 4-29-21 1:35:46 4-29-21 1:35:13 4-29-21 1:35:19 4-29-21 1:35:25 2.940 2.999 2.865 2.872 643.8 651.9 UPPER PIEDMONT REG. LANDFILL CELLS 7 - 10 J21-1003-81 4-21-21 PZ-140 UNDISTURBED HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) PROJECT:TESTED BY:JOHN MATHEW PROJECT NO.:CHECKED BY:PAUL YARBER DATE RECEIVED: SAMPLE NO. SAMPLE LOCATION:3.0-5.0' TYPE SAMPLE DESCRIPTION:YELLOWISH BROWN SILT w/some fi. Sand SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 7.445 7.419 Sample Diameter 7.257 7.267 Length/Diameter Ratio 1.03 Moisture Content (%)WW= 163.0 DW= 119.7 36.2 WW= 234.5 DW= 169.0 38.8 Sample Wet Weight (grams) Wet Density (pcf) 112.2 113.1 Dry Density (pcf) 82.4 81.5 Saturation (%)ASSUMED SG= 2.7 93 98 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi)70 Influent Pressure (psi)60 Effluent Pressure (psi) 60 B-Value 0.96 Reset Date Clock Time Elapsed Time HAOUT HAIN Temp Gradient K Temp K20°C (Y/N) (cm) (cm) ºC (cm/sec) Correction (cm/sec) Y 7.5 1.77 22.0 10 0:00:49 6.5 1.82 22.0 8 1.8E-06 0.953 1.7E-06 0:01:04 6.2 1.83 22.0 8 1.8E-06 0.953 1.7E-06 0:01:15 6.0 1.84 22.0 7 1.8E-06 0.953 1.7E-06 0:01:26 5.8 1.84 22.0 7 1.8E-06 0.953 1.8E-06 HYDRAULIC CONDUCTIVITY (K20°C)1.7E-06 cm/sec 4-29-21 11:00:19 4-29-21 11:00:30 4-29-21 10:59:04 4-29-21 10:59:53 4-29-21 11:00:08 2.931 2.921 2.857 2.861 553.4 557.3 UPPER PIEDMONT REG. LANDFILL CELLS 7 - 10 J21-1003-81 4-21-21 PZ-148 UNDISTURBED HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) PROJECT:TESTED BY:JOHN MATHEW PROJECT NO.:CHECKED BY:PAUL YARBER DATE RECEIVED: SAMPLE NO. SAMPLE LOCATION:13.0-15.0' TYPE SAMPLE DESCRIPTION:YELLOWISH BROWN FI. SANDY SILT SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 7.590 7.569 Sample Diameter 7.201 7.150 Length/Diameter Ratio 1.05 Moisture Content (%)WW= 138.4 DW= 99.2 39.5 WW= 222.8 DW= 156.8 42.1 Sample Wet Weight (grams) Wet Density (pcf) 108.4 111.0 Dry Density (pcf) 77.7 78.1 Saturation (%)ASSUMED SG= 2.7 91 98 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi)70 Influent Pressure (psi)60 Effluent Pressure (psi) 60 B-Value 0.96 Reset Date Clock Time Elapsed Time HAOUT HAIN Temp Gradient K Temp K20°C (Y/N) (cm) (cm) ºC (cm/sec) Correction (cm/sec) Y 4.7 1.89 22.0 5 0:00:25 4.0 1.92 22.0 4 5.4E-06 0.953 5.2E-06 0:00:39 3.7 1.93 22.0 3 5.4E-06 0.953 5.1E-06 0:00:50 3.5 1.94 22.0 3 5.3E-06 0.953 5.1E-06 0:01:09 3.2 1.95 22.0 2 5.3E-06 0.953 5.1E-06 HYDRAULIC CONDUCTIVITY (K20°C)5.1E-06 cm/sec 4-29-21 11:10:25 4-29-21 11:10:44 4-29-21 11:09:35 4-29-21 11:10:00 4-29-21 11:10:14 2.988 2.980 2.835 2.815 536.5 540.2 UPPER PIEDMONT REG. LANDFILL CELLS 7 - 10 J21-1003-81 4-21-21 PZ-148 UNDISTURBED HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) PROJECT:TESTED BY:JOHN MATHEW PROJECT NO.:CHECKED BY:PAUL YARBER DATE RECEIVED: SAMPLE NO. SAMPLE LOCATION:3.0-5.0' TYPE SAMPLE DESCRIPTION:LIGHT BROWN FI. SANDY SILTY CLAY SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 7.445 7.480 Sample Diameter 7.290 7.333 Length/Diameter Ratio 1.02 Moisture Content (%)WW= 174.3 DW= 156.9 11.1 WW= 212.0 DW= 174.7 21.4 Sample Wet Weight (grams) Wet Density (pcf) 137.9 138.6 Dry Density (pcf) 124.1 114.2 Saturation (%)ASSUMED SG= 2.7 84 100 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi)70 Influent Pressure (psi)60 Effluent Pressure (psi) 60 B-Value 0.96 Reset Date Clock Time Elapsed Time HAOUT HAIN Temp Gradient K Temp K20°C (Y/N) (cm) (cm) ºC (cm/sec) Correction (cm/sec) Y 7.5 1.77 22.0 10 0:05:03 6.5 1.82 22.0 8 2.8E-07 0.953 2.7E-07 0:05:40 6.4 1.82 22.0 8 2.8E-07 0.953 2.7E-07 0:06:16 6.3 1.82 22.0 8 2.8E-07 0.953 2.7E-07 0:06:53 6.2 1.83 22.0 8 2.8E-07 0.953 2.6E-07 HYDRAULIC CONDUCTIVITY (K20°C)2.7E-07 cm/sec 4-29-21 10:31:01 4-29-21 10:31:38 4-29-21 10:24:45 4-29-21 10:29:48 4-29-21 10:30:25 2.931 2.945 2.870 2.887 686.3 701.3 UPPER PIEDMONT REG. LANDFILL CELLS 7 - 10 J21-1003-81 4-21-21 PZ-157 UNDISTURBED HYDRAULIC CONDUCTIVITY TEST REPORT CONSTANT VOLUME APPARATUS (ASTM D 5084) PROJECT:TESTED BY:JOHN MATHEW PROJECT NO.:CHECKED BY:PAUL YARBER DATE RECEIVED: SAMPLE NO. SAMPLE LOCATION:3.0-4.5' TYPE SAMPLE DESCRIPTION:GREY & BROWN FI.-MED. SANDY CLAY SAMPLE DIMENSIONS AND PROPERTIES ITEM INITIAL FINAL inches centimeters inches centimeters Sample Length 7.539 7.610 Sample Diameter 7.303 7.320 Length/Diameter Ratio 1.03 Moisture Content (%)WW= 178.4 DW= 144.9 23.1 WW= 253.8 DW= 201.3 26.1 Sample Wet Weight (grams) Wet Density (pcf) 125.1 125.6 Dry Density (pcf) 101.6 99.6 Saturation (%)ASSUMED SG= 2.7 95 102 HYDRAULIC CONDUCTIVITY TESTING MEASUREMENT (PERMOMETER) Chamber Pressure (psi)70 Influent Pressure (psi)60 Effluent Pressure (psi) 60 B-Value 0.96 Reset Date Clock Time Elapsed Time HAOUT HAIN Temp Gradient K Temp K20°C (Y/N) (cm) (cm) ºC (cm/sec) Correction (cm/sec) Y 7.6 1.77 22.0 10 0:08:32 7.0 1.80 22.0 9 9.6E-08 0.953 9.2E-08 0:10:07 6.9 1.80 22.0 9 9.6E-08 0.953 9.1E-08 0:11:40 6.8 1.80 22.0 9 9.6E-08 0.953 9.1E-08 0:13:25 6.7 1.81 22.0 8 9.5E-08 0.953 9.0E-08 HYDRAULIC CONDUCTIVITY (K20°C)9.1E-08 cm/sec 4-29-21 1:22:18 4-29-21 1:24:03 4-29-21 1:10:38 4-29-21 1:19:10 4-29-21 1:20:45 2.968 2.996 2.875 2.882 632.9 644.5 UPPER PIEDMONT REG. LANDFILL CELLS 7 - 10 J21-1003-81 4-21-21 PZ-160 UNDISTURBED Tested By: PY IV INCREMENTAL CONSOLIDATION TEST REPORT Void Ratio0.75 0.80 0.85 0.90 0.95 1.00 1.05 1.10 1.15 1.20 1.25 Applied Pressure - psf 100 1000 10000 Natural Dry Dens.LL PI Sp. Gr.Overburden Pc Cc Cr Initial Void Saturation Moisture (pcf)(psf)(psf)Ratio 89.0 %38.5 %77.1 46 14 2.65 7178 0.41 0.03 1.147 Yellowish brown fi. sandy SILT ML A-7-5(15) 1003-81 Republic Services of North Carolina, LLC Upper Piedmont Regional Landfill Cells 7 - 10 MATERIAL DESCRIPTION USCS AASHTO Project No.Client:Remarks: Project: Source of Sample: Boring Depth: 13.0-15.0 Sample Number: PZ-148 Bunnell Lammons Engineering, Inc. Greenville, SC Figure Dial Reading vs. Time Project No.: Project: Source of Sample: Boring Depth: 13.0-15.0 Sample Number: PZ-148 Load No.= Load= D0 = D90 = D100 = T90 = Cv @ T90 7.732 ft.2/day Load No.= Load= D0 = D90 = D100 = T90 = Cv @ T90 7.688 ft.2/day 1003-81 Upper Piedmont Regional Landfill 2 500 psf -0.3640 -0.3618 -0.3616 0.27 min. 3 1000 psf -0.3620 -0.3585 -0.3582 0.28 min.Dial Reading (in.)-0.3597 -0.3600 -0.3603 -0.3606 -0.3609 -0.3612 -0.3615 -0.3618 -0.3621 -0.3624 -0.3627 Square Root of Elapsed Time (min.) 0 4 8 12 16 20 24 28 32 36 40 t90 Dial Reading (in.)-0.3560 -0.3564 -0.3568 -0.3572 -0.3576 -0.3580 -0.3584 -0.3588 -0.3592 -0.3596 -0.3600 Square Root of Elapsed Time (min.) 0 4 8 12 16 20 24 28 32 36 40 t90 FigureBunnell Lammons Engineering, Inc. Dial Reading vs. Time Project No.: Project: Source of Sample: Boring Depth: 13.0-15.0 Sample Number: PZ-148 Load No.= Load= D0 = D90 = D100 = T90 = Cv @ T90 7.285 ft.2/day Load No.= Load= D0 = D90 = D100 = T90 = Cv @ T90 3.553 ft.2/day 1003-81 Upper Piedmont Regional Landfill 4 2000 psf -0.3547 -0.3502 -0.3497 0.29 min. 5 4000 psf -0.3408 -0.3355 -0.3349 0.57 min.Dial Reading (in.)-0.344 -0.345 -0.346 -0.347 -0.348 -0.349 -0.350 -0.351 -0.352 -0.353 -0.354 Square Root of Elapsed Time (min.) 0 4 8 12 16 20 24 28 32 36 40 t90 Dial Reading (in.)-0.330 -0.331 -0.332 -0.333 -0.334 -0.335 -0.336 -0.337 -0.338 -0.339 -0.340 Square Root of Elapsed Time (min.) 0 4 8 12 16 20 24 28 32 36 40 t90 FigureBunnell Lammons Engineering, Inc. Dial Reading vs. Time Project No.: Project: Source of Sample: Boring Depth: 13.0-15.0 Sample Number: PZ-148 Load No.= Load= D0 = D90 = D100 = T90 = Cv @ T90 3.752 ft.2/day Load No.= Load= D0 = D90 = D100 = T90 = Cv @ T90 7.443 ft.2/day 1003-81 Upper Piedmont Regional Landfill 8 2000 psf -0.3373 -0.3368 -0.3367 0.54 min. 9 4000 psf -0.3342 -0.3318 -0.3315 0.27 min.Dial Reading (in.)-0.3354 -0.3356 -0.3358 -0.3360 -0.3362 -0.3364 -0.3366 -0.3368 -0.3370 -0.3372 -0.3374 Square Root of Elapsed Time (min.) 0 4 8 12 16 20 24 28 32 36 40 t90 Dial Reading (in.)-0.3292 -0.3296 -0.3300 -0.3304 -0.3308 -0.3312 -0.3316 -0.3320 -0.3324 -0.3328 -0.3332 Square Root of Elapsed Time (min.) 0 4 8 12 16 20 24 28 32 36 40 t90 FigureBunnell Lammons Engineering, Inc. Dial Reading vs. Time Project No.: Project: Source of Sample: Boring Depth: 13.0-15.0 Sample Number: PZ-148 Load No.= Load= D0 = D90 = D100 = T90 = Cv @ T90 6.818 ft.2/day Load No.= Load= D0 = D90 = D100 = T90 = Cv @ T90 3.127 ft.2/day 1003-81 Upper Piedmont Regional Landfill 10 8000 psf -0.3247 -0.3113 -0.3098 0.29 min. 11 16000 psf -0.2836 -0.2684 -0.2668 0.58 min.Dial Reading (in.)-0.3015 -0.3030 -0.3045 -0.3060 -0.3075 -0.3090 -0.3105 -0.3120 -0.3135 -0.3150 -0.3165 Square Root of Elapsed Time (min.) 0 4 8 12 16 20 24 28 32 36 40 t90 Dial Reading (in.)-0.2550 -0.2575 -0.2600 -0.2625 -0.2650 -0.2675 -0.2700 -0.2725 -0.2750 -0.2775 -0.2800 Square Root of Elapsed Time (min.) 0 4 8 12 16 20 24 28 32 36 40 t90 FigureBunnell Lammons Engineering, Inc. Dial Reading vs. Time Project No.: Project: Source of Sample: Boring Depth: 13.0-15.0 Sample Number: PZ-148 Load No.= Load= D0 = D90 = D100 = T90 = Cv @ T90 2.838 ft.2/day 1003-81 Upper Piedmont Regional Landfill 12 32000 psf -0.2378 -0.2137 -0.2110 0.57 min.Dial Reading (in.)-0.200 -0.203 -0.206 -0.209 -0.212 -0.215 -0.218 -0.221 -0.224 -0.227 -0.230 Square Root of Elapsed Time (min.) 0 4 8 12 16 20 24 28 32 36 40 t90 FigureBunnell Lammons Engineering, Inc. Tested By: PY IV TRIAXIAL SHEAR TEST REPORT Bunnell Lammons Engineering, Inc. Greenville, SC Client: Republic Services of North Carolina, LLC Project: Upper Piedmont Regional Landfill Cells 7 - 10 Source of Sample: Boring Depth: 23.0-25.0 Sample Number: PZ-148 Proj. No.: 1003-81 Date Sampled: Type of Test: CU with Pore Pressures Sample Type: Undisturbed Description: Light brown, yellow & black fi. sandy elastic SILT LL= 54 PI= 22PL= 32 Specific Gravity= 2.65 Remarks: Figure Sample No. Water Content, % Dry Density, pcf Saturation, % Void Ratio Diameter, in. Height, in. Water Content, % Dry Density, pcf Saturation, % Void Ratio Diameter, in. Height, in. Strain, % Strain, % Total Pore Pr., psi Total Pore Pr., psi Strain rate, in./min. Eff. Cell Pressure, psi Fail. Stress, psi Ult. Stress, psi s1 Failure, psi s3 Failure, psiInitialAt Test1 47.9 71.4 96.4 1.3175 2.856 6.000 51.3 70.1 100.0 1.3597 2.889 5.970 0.015 3.3 6.93 15.27 42.06 12.38 39.86 15.0 4.87 20.15 2 43.0 75.7 96.2 1.1859 2.845 6.000 45.9 74.6 100.0 1.2167 2.887 5.909 0.015 4.8 20.80 26.76 50.03 26.98 48.25 15.0 10.77 37.53 3 47.3 71.6 95.6 1.3111 2.855 6.000 41.0 79.2 100.0 1.0877 2.763 5.785 0.015 4.9 62.39 46.04 69.53 37.46 69.36 15.0 22.86 68.91Deviator Stress, psi0 10 20 30 40 50 60 Axial Strain, % 0 5 10 15 20 1 2 3Shear Stress, psi0 19 38 57 Total Normal Stress, psi Effective Normal Stress, psi 0 19 38 57 76 95 114 C, psi f, deg Tan(f) Total Effective 5.350 12.20 0.22 2.314 27.31 0.52 Tested By: PY IV Client: Republic Services of North Carolina, LLC Project: Upper Piedmont Regional Landfill Source of Sample: Boring Depth: 23.0-25.0 Sample Number: PZ-148 Project No.: 1003-81 Figure Bunnell Lammons Engineering, Inc.q, psi0 20 40 60 p, psi Stress Paths: Total Effective 0 20 40 60 80 100 120 Peak Strength Total Effective a= a= tan a= 5.229 psi 11.93 deg 0.21 2.056 psi 24.64 deg 0.46Total Pore Pressure Deviator Stress psi0 20 40 60 80 100 0%8%16% 1 Total Pore Pressure Deviator Stress psi0 20 40 60 80 100 0%8%16% 3 Total Pore Pressure Deviator Stress psi0 20 40 60 80 100 0%8%16% 2 Total Pore Pressure Deviator Stress psi0 20 40 60 80 100 0%8%16% 4 Tested By: JM Checked By: PY IV TRIAXIAL SHEAR TEST REPORT Bunnell Lammons Engineering, Inc. Greenville, SC Client: Republic Services of North Carolina, LLC Project: Upper Piedmont Regional Landfill Cells 7 - 10 Source of Sample: Boring Depth: 2.0-8.0 Sample Number: PZ-159 Proj. No.: 1003-81 Date Sampled: Type of Test: CU with Pore Pressures Sample Type: Description: Grey clayey fi.-co. SAND LL= 30 PI= 11PL= 19 Assumed Specific Gravity= 2.7 Remarks: Figure Sample No. Water Content, % Dry Density, pcf Saturation, % Void Ratio Diameter, in. Height, in. Water Content, % Dry Density, pcf Saturation, % Void Ratio Diameter, in. Height, in. Strain, % Strain, % Total Pore Pr., psi Total Pore Pr., psi Strain rate, in./min. Eff. Cell Pressure, psi Fail. Stress, psi Ult. Stress, psi s1 Failure, psi s3 Failure, psiInitialAt Test1 13.9 115.4 81.3 0.4600 2.865 6.000 17.7 114.0 100.0 0.4782 2.886 5.986 0.015 5.3 6.99 10.72 62.71 13.83 60.62 15.0 4.28 15.00 2 13.9 115.4 81.6 0.4608 2.865 6.000 16.4 116.8 100.0 0.4432 2.855 5.968 0.015 6.0 20.80 22.40 71.01 26.99 67.96 14.9 9.79 32.19 3 13.2 116.1 79.1 0.4524 2.865 6.000 14.4 121.3 100.0 0.3892 2.812 5.958 0.015 7.7 62.67 57.65 73.42 68.61 69.50 14.8 27.25 84.91Deviator Stress, psi0 15 30 45 60 75 90 Axial Strain, % 0 5 10 15 20 1 2 3Shear Stress, psi0 30 60 90 Total Normal Stress, psi Effective Normal Stress, psi 0 30 60 90 120 150 180 C, psi f, deg Tan(f) Total Effective 1.787 17.24 0.31 0.634 30.30 0.58 Tested By: JM Checked By: PY IV Client: Republic Services of North Carolina, LLC Project: Upper Piedmont Regional Landfill Source of Sample: Boring Depth: 2.0-8.0 Sample Number: PZ-159 Project No.: 1003-81 Figure Bunnell Lammons Engineering, Inc.q, psi0 20 40 60 p, psi Stress Paths: Total Effective 0 20 40 60 80 100 120 Peak Strength Total Effective a= a= tan a= 1.707 psi 16.51 deg 0.30 0.547 psi 26.77 deg 0.50Total Pore Pressure Deviator Stress psi0 20 40 60 80 100 0%8%16% 1 Total Pore Pressure Deviator Stress psi0 20 40 60 80 100 0%8%16% 3 Total Pore Pressure Deviator Stress psi0 20 40 60 80 100 0%8%16% 2 Total Pore Pressure Deviator Stress psi0 20 40 60 80 100 0%8%16% 4 APPENDIX I Fracture Trace Analysis Data ROSE DIAGRAM OF FRACTURE TRENDS Upper Piedmont Regional MSW Landfill, Person Co., NC BLE Job Number J21-1003-81 rose diagram 1003-81 str-dip all data 0.0% 5.0% 10.0% 15.0%NORTH SOUTH EASTWEST N = N11-40E 144 N81-90W N31-40W Stereo 2 1003-81 str-dip all data Southern Hemosphere Stereo Projection Equal Angle PLOT OF POLES TO GEOLOGIC FEATURES Upper Piedmont Regional MSW Landfill -Person County, NC BLE Job Number J21-1003-81 Joints Joints & Foliation Veins Bedding NORTH N = 144 SOUTH EASTWEST+ APPENDIX J Surface Geophysical Methods and Data APPENDIX J Surface Geophysical Methods and Data MAGNETOMETER A magnetometer measures the earth's magnetic field. The value of the earth's field is measured in nanoteslas (nT) with the total field typically being on the order of 50,000 nT in the United States. Buried conductive sources, such as ferromagnetic associated minerals, may perturb the local magnetic field and produce short wavelength anomalies. Anomaly shapes and amplitudes are dependent upon latitude of the site and shape of the target. Superimposed anomalies may occur at locations of multiple sources. The magnetometer may also be affected by cultural "noise" such as power lines, fences and buildings. If there is too much cultural "noise," no useful data can be collected. There are different types of magnetometers that measure the earth’s field (either total field or a component) in various ways. Typically, a portable proton precession magnetometer is used. A Geometrics Portable Proton Magnetometer Model G-856A was used for this study. This magnetometer is designed to use the principle of spinning protons processing in a fluid to measure the total magnetic field. The spinning protons are temporarily aligned by applying a local magnetic field generated by a current in a coil of wire. Removal of the current causes the protons to process about the earth's magnetic field. The precession generates a small signal in the coil of wire, which has a frequency proportional to the total magnetic field intensity. Measurements are taken at discrete locations. A magnetic gradiometer is often used instead of a conventional magnetometer. A magnetic gradiometer measures the magnetic field in the same way but has two detectors at different distances above the ground. Measurements from both detectors are taken simultaneously and the total field and the difference between the detectors are recorded. "Magnetic storms" are natural phenomena that occur from time to time. In order to test for magnetic storms and magnetic drift a "base station" is typically reoccupied every 1 to 3 hours on longer surveys, or at the beginning and end of a traverse on shorter surveys. Such a reoccupation generally yields values within a few nanoteslas of the original reading. During a storm, data collected should be used with caution.