Loading...
HomeMy WebLinkAboutNCD980602163_20011206_Warren County PCB Landfill_SERB C_No. 87 - Nonshrink Grout Data Literature-OCRTRANSMITTAL COVER PAGE WARREN COUNTY PCB LANDFILL DETOXIFICATION PROJECT IT Corp. Project #827062 Submitted By: IT Corporation -200 Horizon Center Boulevard, Trenton, New Jersey 08691 Transmittal Number (chronological sequence): _Q.21 Transmittal Date: 12/6/01 Submittal Register Item Number: 87 Resubmittal: No_..X Yes __ Specification Section: 03600 1.02 A Description: Manufacturer's Literature on Grout used to repair crack between pads 3 and 4 Drawing/Detail Number: NI A Subcontractor/Supplier Blair Comments: NIA Number of Copies Submitted: _4_ Number of Copies to be Returned to Contractor_0'"-_ Earth Tech Engineer's Receipt Signature: ___________________ _ Comments: Receipt Date: Engineer's Approval Comments: Reviewer's Signature Project Manager's Signature D A. "Reviewed and approved, no exceptions taken" D B. "Reviewed and approved with comments D C. "Revise and Resubmit" Date ------------------------- _______________ Date ________ _ ' Dec 05 01 04:09p BlairDuron Res~oration 9198334955 ( THE EUCLID CHEMICAL COMPANY (216) s31 -9222 19218 REDWOOD ROAD (800) 321-7628 • CLEVELAND, OH 44110 FAX (216) 531-9596 NS GROUT ♦ ♦ ♦ ♦ ♦ NON-SHRINK, NON-STAIN, NON-METALLIC NS GROUT is designed for critical use where high strength, non-staining characteristics and positive ex- pansion are required. It contains only natural aggregate and an expansive cementitious binder. It is extremely flowabfe, and when cured, appears similar in appear- ance to concrete. PRIMARY APPLICATIONS • Pumps • Fans • Motors • Compressors • Generators • Machine bases of all types • Anchor bolts • Column baseplates FEATURES/ BENEFITS • Non-staining natural aggregate for better appearance • Non-shrink performance provides excellent bearing • Flowable and self-leveling • High strength • Appearance of plain concrete • Does not contain any added chloride ions SPECIFICATION / COMPLIANCES • Meets the requirements of CAD C-621, Corps of Engineers Specification for Non-Shrink Grout. • Shows positive expansion when tested in accordance with ASTM Specification C-1090, Standard Test Method for Measuring Changes in Height of Cylindri- cal Specimens from Hydraulic-Cement Grout. • Meets the performance requirements of ASTM C- 1107, Grades A & Bas well as Grade C, combination volume adjusting grout standard specification for packaged dry, hydraulic-cement grout (non-shrink- able}. IE.CHNICAL INFORMATION Typical Engineering Data The followlng results were developed under laboratory conditions. Flowable Consistency 1.0 gal/50 lb (3.8 liter/22.7 kg} Flow Rate: ASTM C-939 & CAD C-621 120% Flow (flow table) Compressive Strength 2" (50 mm) cubes (ASTM C-109) ~ Strength 3 days 5,000 psi (34 MPa) 7 days 7,000 psi (48 MPa) 14 days 8,000 psi (55 MPa) 28 days 9,000 psi (62 MPa) Expansion Tested in Accordance with CAD C-621 3 days .01% 7 days .06% 14 days .06% 28 days .06% Fluid Consistency 1.2 gal/SO lb (4.5 liter/22.7 kg) Flow Rate: ASTM C-939 & CAD C-621 20 to 30 seconds (Flow Cone) Compressive Strength 2" (50 mm) cubes (ASTM C-109) ~ Strength 3 days 4,000 psi (28 MPa) 7 days 6,000 psi (41 MPa) 14 days 6,500 psi (45 MPa) 28 days 7,000 psi {48 MPa) Expansion Tested in Accordance with CAD C-621 3 days .01% 7 days .06% 14 days .06% 28 days .06% Setting Time ASTM C-191 Initial Set 3 hrs 5 mins. Final Set 4 hrs 47 mins A Holderchem / RPM Company p.4 ) ' Dec 05 01 04:09p BlairDuron Res~oration 9198334955 Appearance NS GROUT is a free flowing powder designed to be mixed with water. After mixing and placing, the color may initially appear much darker than the surrounding concrete. While this color will lighten up substantially as the concrete cures and dries out, the grout may always appear somewhat darker than the surrounding con- crete. PACKAGING / YIELD NS GROUT is packaged in 50 lb (22.7 kg) bags and yields 0.45 ft3 (0.013 m3) of fluid grout when mixed with 1.2 gal (4.5 liter) of water. 50 lb (22. 7 kg) of NS GROUT and 25 lbs (11.3 kg} of 3/8" (9.5 mm) pea gravel will yield approximately 0.60 ft3 (.017 m3) of flowable consistency grout. Use pea gravel for deep fills only. DIRECTIONS FOR USE The contractor and engineer are encouraged to con- sult and review the Euclid Chemical bulletin "Applica- tion Instructions -Cementitlous Grouting." The docu- ment offers instructions detailing the general installa- tion of Euclid Chemlcar manufactured cement-based grout products. Note: If the contractor is not familiar with standard grout placement techniques, a pre-job meeting is sug- gested to review the project details unique to the par- ticular job. Contact your local Euclid Chemical repre- sentative for additional information. The information given here is offered in particular support to the mixing and placing of NS GROUT. This information should be used in conjunction with the Application Instructions guide mentioned above. Mixing: Consistency Estimated Water Content* Fluid 1.2 gal/50 lb bag (4.5 liter/22.7 kg) Flowable 1.0 gal/50 lb bag (3.8 liter/22.7 kg) Plastic .9 gal/50 lb bag (3.4 liter/22.7 kg) • Do not add water in an amount that will cause bleeding or segregation. More or less water may be required to achieve a 25 second flow or the desired placing consistency, depending on temperature and other variables. Do not add sand or cement to the grout since this action will change its precision grouting ·characteristics. Do not use this product at a flow cone rate of less than 20 seconds it checking flow rates on the job site (see CRD-C-611 of ASTM C-939 for flow cone method). Where NS GROUT will be placed at a thickness over 2" (50.8 mm), up 25 lb (11 .3 kg) of pea gravel may be added to each bag of grout. Note that the water demand to achieve a certain flow level of the grout will change. Do not add sufficient water to promote bleeding of the grout. Placing-NS GROUT sets more rapidly than plain mortars; therefore, place quickly and continuously. If placing this product in hot weather, use of cold water will increase the working time. Curing and Sealing-Proper curing procedures are importanl to ensure the durability and quality of the grout. Wet cure the grout until the forms are stripped. Then, cure the grout with a high solids curing com- pound, such as SUPER REZ-SEAL, SUPER FLOOR COAT or SUPER AQUA-CURE VOX as described in the general grouting Application Instructions guide. Curing Compound must be ordered separately. CLEAN-UP Clean tools and equipment with water before the material hardens. PRECAUTIONS/ LIMITATIONS • Do not add any admixture or fluidifiers. • Proper curing is required. • Employ cold weather or hot weather grouting prac- tices as the temperatures dictates. • Store materials in a dry place. • Do not allow to freeze until 4000 psi (27.6 MPa) attained. • Do not use as a topping. • Do not use material at temperatures that may cause premature freezing. • Rate of strength gain is significantly affected at temperature extremes. Form NS Grout-4.96 p.5 WARRANTY: lhe Eur.lid Chemic.al Company ("Euclid1 solP.ty and ft•pre!.Sly wenZ11nls lhnt its products sh;till hP f,c,c, lrom rlclem in rn11lerlat~ tt•H:t wo~manshlp for &he (6) months from the dale Cit pllr'Chase. Unless aulhorized In wri1ino by Mt\lficor ot Eucl;d. no other repu1:,ent.:,1~s m Sl;llements ntada hy Euclttt Ot its reprvsenlillivcs. In writing°' orally. shall al\er this warranly. EUCLID MAKES NO WAAAANTIES, IMPUEO OR OTHERWISE, AS TO THE MEACliANT~BILITY OR FITNESS FOIi OIIDINARY OR PARTICUL.An PURPOSES OF ITS PnOOUCTS AND EXCLUDES THE SAME. 11 any Euclid ,.-oduci foil• lo e<>nlonn wto, ttio warran1y, Euclid wiU replace lhe p,oducl al no cost \o Buyor. Reptacemcnl of 11ny Pfodud '°'h,ill bl' tho Role ~nd c•clul\ive •~m~cJy availAt>!e and hu')let shall hRvl:I no claim kw Incidental or consequellti■I damages. Any w1111~n1y clu•m n'lll!;I ho mode wilhh, une t I) year uom the dale ol lhn claimed breach. EucUd does not authorize at1yone on ils behl\lf to malce 11ni,, wrinen or oral MMernenls which In anyw11.y airer Eucild', inslaOetion informc1tk>n o, inslructions In \Is produc;t literillure °' oo ill p.%ck.,QinQ labAIS Ariy install<'lllon ol Eur.lid P'oducls whtth lni\,: lo c.nnlo,m wilh su(h in~lilll;llioo ir1fot1Mllon or inst,uc1ionG shall void 1h15 warranty. Protluct demon~rafiOos. ii any. arf done lor lnuslralive purposes only <'Ind dn not constiluta A w3r,eflly or wilu,,,11y 111\P.rahrin ol any k1nr1 Buyer shill! be solely r~sponsible tor delerminir\ij the suilabrntv or Euclid's 0<ot1or.1, In, lhe 8vyer'4 intended purposes. 0