HomeMy WebLinkAboutNCS01688_INSP_20230602NORTH CARnLINAD_E Q��
o.n.mm.m m c.w.mm.m.i a.i�
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
UNIT TYPE:
Lined
LCID
YW
Transfer
Compost
SLAS
COUNTY: wake
MSWLF
PERMIT NO.: NCS-01688
Closed
HHW
White
Incin
T&P
FIRM
X
MSWLF
goods
FILE TYPE: COMPLIANCE
CDLF
TireT&P/
Tire
Industrial
DEMO
SDTF
Collection
Monofill
Landfill
Date of Site Inspection: 06/02/2023
FACILITY NAME AND ADDRESS:
C & C Septic Services, Inc.
8172 Mount Pleasant Church Road
Willow Spring, NC 27592
GPS COORDINATES: N: NA
Date of Last Inspection:
FACILITY CONTACT INFORMATION:
Name: Joseph Sawvel
Address: PO Box 635 — Willow Spring, NC 27592
Telephone: 919-218-6902
Email address: candcsepticservices@gmaiLcom
PARTICIPANTS: Chester Cobb (DWM)
STATUS OF PERMIT: Pending EXPIRES:
PURPOSE OF SITE VISIT: Pre -operational
STATUS OF PAST NOTED VIOLATIONS:
NA
OBSERVED VIOLATIONS:
NONE
E: NA
The item(s) listed above were observed by Section staff and require action on behalf of the facility in order to come into or maintain compliance
with the Statutes, Rules, and/or other regulatory requirements applicable to this facility. Be advised that pursuant to N.C.G.S. 130A-22, an
administrative penalty of up to $15,000 per day may be assessed for each violation of the Solid Waste Laws, Regulations, Conditions of a Permit,
or Order under Article 9 of Chapter 130A of the N.C. General Statutes. Further, the facility and/or all responsible parties may also be subject to
enforcement actions including penalties, injunction from operation of a solid waste management facility or a solid waste collection service and
any such further relief as may be necessary to achieve compliance with the North Carolina Solid Waste Management Act and Rules.
Pagel of 3
NORTH CARnLINAD_E Q��
oen.mmem m c.w.mmnnai a.i�
ADDITIONAL COMMENTS
1) Pumper vehicle(s) inspected:
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
TRUCK
LICENSE PLATE #
VIN #
TANK CAPACITY (gal)
i
YA176586
2NKHHN8X79M254359
2,500
2) The required information of Firm name, town name, phone #, and permit # was on both sides of the
pumper vehicle. Each letter of the required information was greater than three (3) inches in height. The
phone number listed on the pumper vehicle was 919-333-9124. The lettering was distinguishable and
not blocked from view. The lettering meets the requirements of 15A NCAC 13B .0835(b). See pictures
below.
3) The tank is made of steel and affixed to the frame of the truck as per 15A NCAC 13B .0835(a)(1). Only
noticed 6 bolts holding the tank to the frame. Typically, I see 12 bolts, 6 to each side. May want to have
it checked to make sure that the 6 bolts are adequate.
4) The valves appeared to be in working order and closed as per 15A NCAC 13B .0835(a)(2). Caps present
on ports.
5) Access ports were closed and properly sealed as per 15A NCAC 13B .0835(a)(3). Split lock washer notice
for bottom bolt of the back access port. See picture below. The nut was tight at time of inspection.
Please keep watch of bolt. May want to go ahead and replace the lock washer.
6) No leaks noticed as per 15A NCAC 13B .0835(a).
7) Truck in compliance with the Septage Rules.
i CaC Sep[lc
-Ser-41ces Inc
WILLOW SPRING, NC NCS•01688
I
—
--Ser-
uicesInc' �i�
WILLOW _.,/NSPRING, NC ��CS•ofsse
Driver side of pumper vehicle. I Passenger side of pumper vehicle.
Page 2 of 3
Oepartmenl o� Envimnmental0uali�
FACILITY COMPLIANCE INSPECTION REPORT
Division of Waste Management
Solid Waste Section
Bottom bolt for back access port.
Please contact me if you have any questions or concerns regarding this inspection report.
Digitally signed by Chester Cobb
DN: cn=Chester Cobb, o=NC DEQ,
ou=Division of Waste Management,
email=chester.cobb@ncdenr.gov, c=US
Date: 2023.06.06 13:43:19-04'00' Phone: (919) 707-8283
Chester R. Cobb, Environmental Program Consultant
Division of Waste Management, NCDEQ