Loading...
HomeMy WebLinkAboutWS-9844_45028_CA_CLO_20230119_CO-IAARSpeedway, LLC. 500 Speedway Drive Enon, OH 45323 (800) 643-1948 Underground Storage Tank Removal and Initial Abatement Action Report- Rev 1 Speedway 7940 5729 West Friendly Avenue Guilford College, North Carolina 27410 Project No. 60687379 January 25, 2023 AECOM ii Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 Quality Information Prepared for: Physical Address: Speedway LLC 500 Speedway Drive Enon, OH 45323 (800) 643-1948 Mailing Address: Speedway LLC PO Box 1500 Springfield, OH 45501 Prepared by: AECOM 5438 Wade Park Boulevard, Suite 200 Raleigh, NC 27607, USA Phone: (919) 461-1100 aecom.com Copyright © 2022 by AECOM All rights reserved. No part of this copyrighted work may be reproduced, distributed, or transmitted in any form or by any means without the prior written permission of AECOM. Prepared by Reviewed by Reviewed by Carter Paradis Geologist II Carter.paradis@aecom.com Nathan Pinsker Project Manager Nathan.Pinsker@aecom.com Marie Treiber Regional Senior Project Manager Marie.Treiber@aecom.com AECOM iii Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 Professional Certification Page I, Brett Schaefer, a Professional Engineer for AECOM Technical Services of North Carolina, Inc., do certify that the information contained in this report is correct and accurate to the best of my knowledge. _________________________________ Brett G. Schaefer, PE AECOM Technical Services of North Carolina, Inc. AECOM Technical Services of North Carolina, Inc. is licensed to practice engineering in North Carolina. The certification number of the company or corporation is F-0458. AECOM iv Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 Table of Contents Executive Summary ............................................................................................................................................. 1-1 1 Introduction ............................................................................................................................................... 1-2 2 Site Background Information...................................................................................................................... 2-1 2.1 Site Identification ............................................................................................................................ 2-1 2.2 Contact Information ........................................................................................................................ 2-1 3 Site History and Characterization ............................................................................................................... 3-1 3.1 Underground Storage Tank Systems ............................................................................................... 3-1 3.2 Aboveground Storage Tank Systems............................................................................................... 3-1 3.3 Historical Releases ......................................................................................................................... 3-1 3.4 Site Characteristics ........................................................................................................................ 3-1 3.4.1 Zoning ................................................................................................................................ 3-1 3.5 Water Supply Wells ........................................................................................................................ 3-1 3.6 Surface Water ................................................................................................................................ 3-1 3.7 Wellhead Protection Areas .............................................................................................................. 3-2 3.8 Subsurface Structures .................................................................................................................... 3-2 3.9 Land Use ....................................................................................................................................... 3-2 3.10 Site Geology .................................................................................................................................. 3-2 3.11 Site Hydrogeology .......................................................................................................................... 3-2 3.12 Initial Abatement Activities .............................................................................................................. 3-2 4 Underground Storage Tank Closure Activities ............................................................................................. 4-1 4.1 Pre-Closure and Closure Activities .................................................................................................. 4-1 4.2 Sample Collection .......................................................................................................................... 4-1 4.2.1 Closure Sampling ................................................................................................................ 4-1 4.2.2 Over-Excavation Sampling................................................................................................... 4-1 5 Summary .................................................................................................................................................. 5-1 6 References ............................................................................................................................................... 6-1 AECOM v Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 Appendix Appendix A. UST-3 Form – Notice of Intent: UST Permanent Closure or Change in Service Appendix B. UST-2A Form – Site Investigation Report for Permanent Closure or Change-in-Service of UST Appendix C. UST-61 Forms - 24-Hour Release and UST Leak Reporting Form Appendix D. Liquid Disposal Manifests Appendix E. Fire Marshall Report Appendix F.UST Disposal Certificate Appendix G. Photographic Log Appendix H. Soil Disposal Manifests Appendix I.Laboratory Analytical Reports Figures Figure 1-1.Site Location Map Figure 1-2.Site Map Figure 4-1.Closure/Over-Excavation Sample Location Map Tables Table 3-1.Site History – UST Owner/Operator Table 3-2.Site History – UST System and Other Release Information Table 4-1.Summary of Closure Soil Sampling Results Table 4-2. Summary of Over-Excavation Soil Sampling Results AECOM vi Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 Acronyms AECOM AECOM Technical Services of North Carolina, Inc. AST aboveground storage tanks bgs below ground surface DRO Diesel range organics EPA United States Environmental Protection Agency GRI Geologic Resources, Inc. GRO gasoline range organics MSCC maximum soil contaminant concentration mg/kg milligrams-per-kilogram NCDEQ North Carolina Department of Environmental Quality NFA no further action NORR Notice of Regulatory Requirements NORP Notice of Residual Petroleum PID photo ionization detector ppm parts-per-million PUL premium unleaded RUL regular unleaded Site Speedway 7940 S-W Soil-to-Water TPH total petroleum hydrocarbons UST underground storage tank AECOM 1-1 Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 Executive Summary As required by the North Carolina Department of Environmental Quality (NCDEQ), AECOM prepared this Underground Storage Tank Removal and Initial Abatement Action Report on behalf of Speedway, LLC (Speedway) for Speedway No. 7940 (Site), located at 5729 West Friendly Avenue, Guilford College, Guilford County, North Carolina. Currently a single-story convenience store exists on-site where Speedway operates a petroleum dispensing system associated with retail fuel sales. Five underground storage tanks (USTs) were removed from the site. The removed UST system was replaced with one 12,000-gallon PUL gasoline UST, one 12,000-gallon RUL gasoline UST and one 12,000-gallon compartment tank which consisted of one 8,000-gallon compartment for diesel, and one 4,000-gallon compartment for kerosene. The site contained five steel single-walled lined underground storage tanks (USTs): two 8,000-gallon tanks containing regular unleaded (RUL) gasoline (UST #1 and UST #2), one 8,000-gallon tank containing premium unleaded (PUL) gasoline (UST #3), one 8,000-gallon tank containing kerosene fuel (UST #4), and one 8,000-gallon tank containing diesel (DSL) (UST#5) which were installed January 1, 1976. Prior to removal activities, the tank compartments were emptied, washed, and then made inert with dry ice. The USTs were removed from the ground on October 28, 2022. The USTs were observed to be in good condition. AECOM collected 15 soil samples from under the USTs, seven from under the dispensers, and eight from under the product lines for analysis of gasoline range organics (TPH-GRO) and/or TPH diesel range organics (TPH-DRO). Multiple closure samples exceeded the NCDEQ action levels. Three risk-based soil samples were collected from the bottom of the excavation and two risk-based soil samples were collected from under the canopy. The risk-based were analyzed for volatile organic compounds (VOCs) and Massachusetts Department of Environmental Protection (MADEP) volatile petroleum hydrocarbons (VPH). Two samples of the five samples were also submitted for analysis of semi-volatile organic compounds (SVOCs) and MADEP extractable petroleum hydrocarbons (EPH). Analytical results indicated that the one or more VOCs were above Soil to Ground (S-G) Maximum Soil Contaminant Concentrations (MSCCs) in the five soil samples collected and were above Residential MSCCs in three of the five soil samples [DE-1, D-1, PL-8 (RISK)] collected. One or more MADEP VPH compounds were above S-G MSCCs in three of the five soil samples collected and Residential MSCCs in one of the five soil samples (DE-1) collected. Naphthalene and MADEP VPH C9-C10 Aromatic (Unadjusted) compounds exceeded Industrial Commercial MSCCs in one soil sample (DE-1). To mitigate soil contamination, AECOM oversaw the removal of 1,167.05 tons of soil from the UST excavation area and the dispenser island excavation area. The excavation for the new USTs was approximately 40 feet x 35 feet x 15 feet. The site has one previous release. Incident number 45028 was opened April 12, 2018 following at Site Check of the RUL UST spill bucket. On April 11, 2022, a Notice of Residual Petroleum (NORP) for restrictions to groundwater and soil was filed at Guilford County Register of Deeds. On April 11, 2022, a Conditional Notice of No Further Action was issued by NCDEQ. Due to the soil samples that exceeded commercial standards at the bottom of the UST excavation, AECOM, on behalf of Speedway, recommends installing one groundwater monitoring downgradient of the USTs to assess groundwater. . AECOM 1-2 Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 1 Introduction As required by the NCDEQ, AECOM prepared this Underground Storage Tank Removal and Initial Abatement Action Report on behalf of Speedway, LLC (Speedway) for Speedway No. 7940 (Site), located at 5729 West Friendly Avenue, Guilford College, Guilford County, North Carolina (Figure 1-1 and Figure 1-2). The site contained five steel single-walled lined underground storage tanks (USTs): two 8,000-gallon tanks containing regular unleaded (RUL) gasoline (UST #1 and UST #2), one 8,000-gallon tank containing premium unleaded (PUL) gasoline (UST #3), one 8,000-gallon tank containing kerosene fuel (UST #4), and one 8,000-gallon tank containing diesel (DSL) (UST#5) which were installed January 1, 1976. A copy of the UST-3 Form (Notice of Intent: UST Permanent Closure or Change in Service) is included in Appendix A and a copy of the UST-2A Form (Site Investigation Report for Permanent Closure or Change in Service of UST) is included as Appendix B. The removed UST system was replaced with one 12,000-gallon PUL gasoline UST, one 12,000-gallon RUL gasoline UST and one 12,000-gallon compartment tank which consisted of one 8,000-gallon compartment for diesel, and one 4,000-gallon compartment for kerosene. The following report summarizes the removal of the USTs and initial abatement. AECOM 2-1 Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 2 Site Background Information The following sections provide site background and contact information. 2.1 Site Identification – Date of Incident Report:November 15, 2022 – Facility ID: 0000023295 Incident Number: TBD – Site Rank:Not Applicable – Site Name:Speedway Store # 7940 – Site Street Address: 5729 West Friendly Avenue – City/Town: Guilford College, NC Zip Code: 27410 County: Guilford – Description of Geographical Data Point (e.g., dispenser): Center of convenience store – Location Method (global positioning system, topographical map, other): Google Earth – Latitude (decimal degrees): 36.08954, Longitude (decimal degrees): -79.88834° 2.2 Contact Information – UST Owner: Speedway LLC – Address: 500 Speedway Drive Enon, Ohio 45323 Telephone: (919) 268-7176 – UST Operator: Speedway LLC Address: 500 Speedway Drive Enon, Ohio 45323 Telephone: (919) 516-8069 – Property Owner: Speedway LLC Address: 500 Speedway Drive Enon, Ohio 45323 Telephone: (919) 516-8069 – Property Occupant: Speedway LLC Address: 500 Speedway Drive Enon, Ohio 45323 Telephone: (919) 516-8069 – Consultant/Contractor: AECOM Address: 5438 Wade Park Boulevard, Suite 200 Raleigh, NC Telephone: (919) 461-1100 – Analytical Laboratory: Pace Analytical State Certification No. 5342 Address: 9800 Kincey Avenue # 100, Huntersville, NC 28078 Telephone: (704) 875-9092 AECOM 3-1 Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 3 Site History and Characterization The following sections provide information on the USTs operated at the site and follows the general outline established in Guidelines for Site Checks, Tank Closure, and Initial Response and Abatement for UST Releases (NCDEQ, 2021). 3.1 Underground Storage Tank Systems UST owner operator and other responsible party information are provided in Table 3-1. A summary of current and former USTs maintained at the site is provided below and summarized in Table 3-2. The site contained five single-walled lined steel USTs: two 8,000-gallon tanks containing RUL gasoline (UST #1 and UST #2), one 8,000-gallon tank containing PUL gasoline (UST #3), one 8,000-gallon tank containing kerosene fuel (UST #4), and one 8,000-gallon tank containing DSL (UST#5) which were installed January 1, 1976. 3.2 Aboveground Storage Tank Systems No aboveground storage tank systems (ASTs) are currently present on-site. Based on available information, no ASTs have historically been present at the site. 3.3 Historical Releases The site has one previous release. Incident number 45028 was opened April 12, 2018 following at Site Check of the RUL UST spill bucket. On December 13, 2021, NCDEQ issued a Notice of Regulatory Requirement (NORR) for a Notice of Residual Petroleum (NORP). On February 23, 2022, all on site monitoring wells have been abandoned. On April 11, 2022, a NORP for restrictions to groundwater and soil was filed at Guilford County Register of Deeds. On April 11, 2022, a Conditional Notice of No Further Action was issued by NCDEQ. 3.4 Site Characteristics The location of the Site is shown on a portion of the United States Geological Survey 7.5-minute topographic map of the Guilford, NC (2022) Quadrangle (Figure 1-1). The layout of the Site is found on Figure 1-2. The Site is currently an active Speedway convenience store with gasoline operations located at 5729 West Friendly Avenue, Greensboro, NC. 3.4.1 Zoning The subject site is located in Greensboro, Guilford County, North Carolina. The site is accessible from West Friendly Avenue on the North and College Road on the South. The site currently operates as a Speedway convenience store with retail gasoline, kerosene, and diesel sales. The Site and surrounding area are a mixture of residential, public/institutional, and commercial properties. 3.5 Water Supply Wells On November 28, 2018, Geologic Resources, Inc. (GRI) (Speedway’s former consultant) conducted a receptor survey at the Site. Two non-potable water supply wells (WSW-1 and WSW-2) were identified within a 1,500-foot radius of the site, one (WSW-1) within a 250-foot radius of the site. Subsequently, NCDEQ determined that WSW-1 was not an active water supply well. Public water is available to the subject site and to all surrounding properties. 3.6 Surface Water No surface water was observed on the Site. King George Branch River is approximately 2000 feet West of the Site. AECOM 3-2 Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 3.7 Wellhead Protection Areas According to the NC Wellhead Protection Program internet site, the Site is not located within a wellhead protection area. 3.8 Subsurface Structures There are currently no known subsurface structures (basements, etc.) at the Site that could potentially accumulate fuel vapors. The property and surrounding properties are serviced by various underground utilities. Vapor intrusion sampling has not been conducted at the Site. 3.9 Land Use The Site is currently an active Speedway gas station and building consisting of a Speedway convenience store located in a commercial area. Various commercial properties surround the Site. 3.10 Site Geology According to the Geologic Map of North Carolina (1985) produced by Philip Brown, et al, the referenced site is located within the Charlotte Belt of North Carolina. The bedrock is generally described as foliated to massive, metamorphosed gabbro and diorite. 3.11 Site Hydrogeology The site is located in the Piedmont Physiographic Province of North Carolina. The depth to water across the site is approximately 17 to 21 feet BGS. 3.12 Initial Abatement Activities AECOM collected 15 soil samples from under the USTs, seven from under the dispensers, and eight from under the product lines for analysis of gasoline range organics (TPH-GRO) and/or TPH diesel range organics (TPH-DRO) during the UST removal in November 2022. Multiple closure samples exceeded the NCDEQ action levels. Upon receipt of the analytical results of the closure soil samples collected, AECOM reported the release to NCDEQ on November 15, 2022. The copy of the UST-61 Form (24-Hour Release and UST Leaking Report Form) is included as Appendix C. Three risk-based soil samples were collected from the bottom of the excavation and two risk-based soil samples were collected from under the canopy. The risk-based were analyzed for volatile organic compounds (VOCs) and Massachusetts Department of Environmental Protection (MADEP) volatile petroleum hydrocarbons (VPH). Two samples of the five samples were also submitted for analysis of semi-volatile organic compounds (SVOCs) and MADEP extractable petroleum hydrocarbons (EPH). Analytical results indicated that the one or more VOCs were above Soil to Ground (S-G) Maximum Soil Contaminant Concentrations (MSCCs) in the five soil samples collected and were above Residential MSCCs in three of the five soil samples [DE-1, D-1, PL-8 (RISK)] collected. One or more MADEP VPH compounds were above S-G MSCCs in three of the five soil samples collected and Residential MSCCs in one of the five soil samples (DE-1) collected. Naphthalene and MADEP VPH C9-C10 Aromatic (Unadjusted) compounds exceeded Industrial Commercial MSCCs in one soil sample (DE-1). To mitigate soil contamination, AECOM oversaw the removal of 1,167.05 tons of soil from the UST excavation area and the dispenser island excavation area. The excavation for the new USTs was approximately 40 feet x 35 feet x 15 feet. AECOM 4-1 Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 4 Underground Storage Tank Closure Activities 4.1 Pre-Closure and Closure Activities On October 28, 2022, the five USTs were emptied, washed and vapors were inerted. The tank was then removed. The liquids disposal manifest associated with the removal is included as Appendix D. On October 28, 2022, five single-walled lined steel USTs: two 8,000-gallon tanks containing RUL gasoline (UST #1 and UST #2), one 8,000-gallon tank containing PUL)gasoline (UST #3), one 8,000-gallon UST containing kerosene fuel (UST #4), and one 8,000-gallon tank containing DSL (UST#5) were removed. Notification of intent to permanently close the USTs was made to the NCDEQ Division of Waste Management by 7-Eleven via a UST-3 Form included in Appendix A. A copy of the closure notification form (UST-2A Form [Site Investigation Report for Permanent Closure or Change-in-Service of UST]) is included in Appendix B. Once all the tanks were recorded at or below 10 percent of the lower explosive limit (LEL) by utilizing a combustible gas indicator, the tanks were cleared for removal by the fire marshal representative. The Fire Marshall’s report is included as Appendix E. The USTs were transported to D.H. Griffin Wrecking Co., Inc. of Greensboro, North Carolina for recycling for disposal. The disposal receipt is included as Appendix F. The USTs appeared to be in good condition. The photographic log illustrating the UST removal activities is included as Appendix G. On November 4, 22, 23, and December 2, 2022, AECOM oversaw the removal of approximately 1,167.05 tons of soil from the UST excavation area and the dispenser island excavation area. Copies of the soil manifests are included as Appendix H. 4.2 Sample Collection AECOM, per NCDEQ Guidelines for Site Checks, Tank Closure, and Initial Response and Abatement for UST Releases (NCDEQ, 2021) and the updated Comprehensive Tables for Corrective Action Guidelines dated September 7, 2022, collected 15 soil samples from the limits of the excavation (Figure 4-1 and Figure 4-2). 4.2.1 Closure Sampling During the UST removal activities, AECOM collected 15 soil samples from the bottom of the UST excavation area, seven from under the dispensers, and eight from under the product lines for analysis of TPH-GRO and/or TPH-DRO. 30 of the samples were analyzed for TPH-GRO and 16 samples exceeded the NCDEQ Action Level. 13 samples were analyzed for TPH-DRO and three samples exceeded the NCDEQ Action Level. Laboratory results are summarized in Table 4-1 and the laboratory analytical reports are included as Appendix I. 4.2.2 Over-Excavation Sampling Three risk-based soil samples were collected from the bottom of the UST excavation area and were submitted for analysis of VOCs and MADEP VPH. One of the three samples was also submitted for analysis of SVOCs and MADEP EPH. Naphthalene and MADEP VPH C9-C10 Aromatic (Unadjusted) compounds were above Industrial Commercial MSCCs in one of the three soil samples (DE-1) collected. Two risk-based soil samples were collected from under the canopy. The soil samples were submitted for analysis of VOCs and MADEP VPH and one of the two samples was also submitted for analysis of SVOCs and MADEP EPH. Analytical results indicated that no compounds exceeded the Industrial Commercial standards. Laboratory results are summarized in Table 4-2 and the laboratory analytical reports are included as Appendix I. AECOM 5-1 Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 5 Summary During the current reporting period October 25 through December 2, 2022, the following activities were conducted at the site: – Five single-walled lined steel USTs were removed from the site. – 1,167.05 tons of soil were removed from the tank field and dispenser island excavation area. – Thirty closure samples were collected from beneath the USTs, dispensers, and product lines. Sixteen of the twenty-eight closure samples analyzed for TPH-GRO were above the NCDEQ Action Levels. Three of the thirteen closure samples analyzed for TPH-DRO were above the NCDEQ Action Level. – Five risk-based soil samples were collected from the bottom of the UST excavation area and beneath the dispenser and product line ─ Naphthalene and MADEP VPH C9-C10 Aromatic (Unadjusted) compounds exceeded Industrial Commercial MSCCs in one of the five risk-based samples. Due to the soil samples that exceeded commercial standards at the bottom of the UST excavation, AECOM, on behalf of Speedway, recommends installing one groundwater monitoring downgradient of the USTs to assess groundwater. AECOM 6-1 Speedway 7940, Guilford College, NCUnderground Storage Tank and Initial Abatement Action Report- Rev 1 January 2023 6 References Geologic Map of North Carolina, 2022, https://ncdenr.maps.arcgis.com/apps/MapSeries/index.html?appid=a8281cbd24b84239b29cd2ca798d4a10 Accessed December 1, 2022. NCDEQ, 2021. Guidelines for Site Checks, Tank Closure, and Initial Response and Abatement for UST Releases. Change 10, effective May 17, 2021. NCDEQ, 2022. Water Supply Watersheds. Accessed Dec 1, 2022. https://ncdenr.maps.arcgis.com/apps/webappviewer/index.html?id=80b5a3634eda417880aa6d2abddfb6f2 North Carolina Wellhead Protection Program, SWAPInfo 2.0. Accessed December 1, 2022. https://nc.maps.arcgis.com/apps/webappviewer/index.html?id=5fee819063f241d685d569ef1be357cf, Figures 2,0002,000 N SITE LOCATION I. DUMITRU FIGURE 1-1SITE LOCATION MAP Source: Topo USGS 7.5 Minute Topographic Map Quadrangle: Guilford, NC Copyright: 2022 National Geographic Society DATE:DRAWN BY:REVIEWED BY:PROJECT NO.:File: C:\Confidential\AECOM\7-Eleven\Sites Folders\North Carolina\7940 Guilford College\7940 Guilford College.dwg Layout: Site Location Map Date: 17 Nov, 2022 Xrefs:00 SCALE IN FEET: NOTE: ALL MAP FEATURES ARE APPROXIMATE IN SCALE AND LOCATION. NOVEMBER 2022 N. PINSKER Speedway Store #7940 5729 West Friendly Avenue Greensboro, North Carolina 60690183 Speedway LLC. © 2022 Microsoft Corporation © 2022 Maxar ©CNES (2022) Distribution Airbus DS SpeedwayStore #7940Trash AreaW e s t F r i e n d l y A v e n u eC o l l e g e R o a dSignAsphalt Parking LotMW-2MW-1MW-4MW-3Canopy & Former Dispenser IslandsFormerTank FieldFormerVentPipesAshmoreRareCoinsandMetalsGraceElectronicsLLCSCALE IN FEET:20200DATE:DRAWN BY:REVIEWED BY:PROJECT NO.:C:\Users\AlexandruIonut.Dumit\AECOM\Convenience Store - 7-Eleven\North Carolina\7940 Guilford College\7940 Guilford College.dwg, 1/23/2023 10:06 AM, Dumitru, Ionut, PDF995.pc3, User32767, 1'-0" = 1'-0"NI. DUMITRUJANUARY 2023N. PINSKERFIGURE 1-2SITE MAPLEGEND#1,#2#3Former 8,000-Gal. RUL GasolineFormer 8,000-Gal. PUL GasolineFormer Product PipingBuried Electric LineNatural Gas LineWater LineNOTE: ALL MAP FEATURES ARE APPROXIMATEIN SCALE AND LOCATION.Speedway Store #79405729 West Friendly AvenueGreensboro, North Carolina60690183Speedway LLC.#4#5Former 8,000-Gal. KeroseneFormer 6,000-Gal. DieselApproximate Property BoundaryFenceFormer Product DispenserFormer Underground Storage TankUtility Pole / Power PoleLight Post / Traffic LightCatch Basin / Stormwater InletOverhead ElectricFormer Monitoring WellFire HydrantApproximate Excavation Area SpeedwayStore #7940Trash AreaW e s t F r i e n d l y A v e n u eC o l l e g e R o a dSignAsphalt Parking LotMW-2MW-1MW-4MW-3Canopy & Former Dispenser IslandsFormerTank FieldFormerVentPipesAshmoreRareCoinsandMetalsGraceElectronicsLLCT-12T-13T-10T-11T-8T-7T-4T-9T-5T-6T-14T-15T-1T-2T-3DE-1DE-2DE-3D-7D-6D-3D-5D-4D-2D-1PL-1PL-8PL-7PL-6PL-5PL-4SCALE IN FEET:20200DATE:DRAWN BY:REVIEWED BY:PROJECT NO.:C:\Users\AlexandruIonut.Dumit\AECOM\Convenience Store - 7-Eleven\North Carolina\7940 Guilford College\7940 Guilford College.dwg, 1/23/2023 10:05 AM, Dumitru, Ionut, PDF995.pc3, User32767, 1'-0" = 1'-0"NI. DUMITRUN. PINSKERFIGURE 4-1SOIL SAMPLE LOCATION MAPSoil Sample Locationand IdentificationT-1DE-1NOTE: ALL MAP FEATURES ARE APPROXIMATEIN SCALE AND LOCATION.Speedway Store #79405729 West Friendly AvenueGreensboro, North Carolina60690183Speedway LLC.LEGEND#1,#2#3Former 8,000-Gal. RUL GasolineFormer 8,000-Gal. PUL GasolineFormer Product PipingBuried Electric LineNatural Gas LineWater Line#4#5Former 8,000-Gal. KeroseneFormer 6,000-Gal. DieselApproximate Property BoundaryFenceFormer Product DispenserFormer Underground Storage TankUtility Pole / Power PoleLight Post / Traffic LightCatch Basin / Stormwater InletOverhead ElectricFormer Monitoring WellFire HydrantJANUARY 2023Over-Excavation Sample Locationand IdentificationExcavation Area Extent of soil excavation Table 3-1 Site History - UST Owner/Operator Speedway Store No. 7940 5729 West Friendly Avenue, North Carolina 27410 Incident Number: TBD Facility Number: 0000023295 UST ID Number 1,2,3,4,5 Facility ID Number 0-023295 City State Zip Telephone Number Enon OH 45323 1-937-863-6507 Historical Incidents UST ID Number 1,2,3,4,5 Facility ID Number 0-023295 City State Zip Telephone Number Winston-Salem NC 27105 1-800-642-0945 Historical Incidents UST ID Number 1,2,3,4,5 Facility ID Number 0-023295 City State Zip Telephone Number Winston-Salem NC 27105 1-800-642-0945 Historical Incidents UST ID Number 1,2,3,4,5 Facility ID Number 0-023295 City State Zip Telephone Number -------- Historical Incidents Address 5446 University Parkway None Date of OperationName of UST Owner/Operator None Unknown 04/15/1985 - 04/21/1986 Address Unknown 5446 University Parkway Name of UST Operator Date of Operation A. T. Williams Oil Company 04/21/1986 - 04/02/2001 None Name of UST Owner/Operator Date of Operation WilcoHess, LLC. 04/02/2001 - 01/01/2016 Address Incident number 45028 was opened April 12, 2018 following at site check of the RUL UST spill bucket. On April 11, 2022, a NORP for restrictions to groundwater and soil was filed at Guilford County Register of Deeds. On April 11, 2022, a Conditional Notice of No Further Action was issued by NCDEQ. Name of UST Owner/Operator Date of Operation Address 500 Speedway Drive Speedway LLC 01/01/2016 - Current Page 1 of 4 Tables Table 3-2 Site History - UST/AST Owner/Operator and Other Release Information Speedway Store No. 7940 5729 West Friendly Avenue, Guilford College, North Carolina 27410 Incident Number: TBD Facility Number: 0000023295 UST ID Number Current / Last Contents Previous Contents Capacity (gallons)Construction Details Tank Dimensions (feet) Associated Piping and Pumps Date Installed Current Status Was release associated with UST System? 1 Regular Gasoline N/A 8,000 Lined Steel 8' x 21' 4"Single Wall FRP 4/17/1976 Removed from Ground N 2 Regular Gasoline N/A 8,000 Lined Steel 8' x 21' 4"Single Wall FRP 4/17/1976 Removed from Ground Y 3 Premium Gasoline N/A 8,000 Lined Steel 8' x 21' 4"Single Wall FRP 4/17/1976 Removed from Ground Y 4 Kerosene N/A 8,000 Lined Steel 8' x 21' 4"Single Wall FRP 4/17/1976 Removed from Ground N 5 Diesel N/A 8,000 Lined Steel 8' x 21' 4"Single Wall FRP 4/17/1976 Removed from Ground N Incident Number Material Released Date of Release 45028 Regular Gasoline 12-Apr-18 Description of Release Incident number 45028 was opened April 12, 2018 following at site check of the RUL UST spill bucket. On April 11, 2022, a NORP for restrictions to groundwater and soil was filed at Guilford County Register of Deeds. On April 11, 2022, a Conditional Notice of No Further Action was issued by NCDEQ. Page 2 of 4 Table 4-1 Summary of Closure Soil Sampling Results Speedway Store No. 7940 5729 West Friendly Avenue, Guilford College, North Carolina 27410 Incident Number: TBD Facility Number: 0000023295 Sample ID Date Collected Source Area Sample Depth (ft bgs) 50 100 T-1 10/28/22 Tank Pit - Bottom 14 NA 7.1 T-2 10/28/22 Tank Pit - Bottom 14 NA 4.0 J T-3 10/28/22 Tank Pit - Bottom 14 38.3 437 T-4 10/28/22 Tank Pit - Bottom 14 7,890 NA T-5 10/28/22 Tank Pit - Bottom 14 70.4 NA T-6 10/28/22 Tank Pit - Bottom 14 4,100 NA T-7 10/28/22 Tank Pit - Bottom 14 604 NA T-8 10/28/22 Tank Pit - Bottom 14 15,500 NA T-9 10/28/22 Tank Pit - Bottom 14 159 NA T-10 10/28/22 Tank Pit - Bottom 14 17,700 NA T-11 10/28/22 Tank Pit - Bottom 14 6,160 NA T-12 10/28/22 Tank Pit - Bottom 14 11,800 NA T-13 10/28/22 Tank Pit - Bottom 14 4,670 10,500 T-14 10/28/22 Tank Pit - Bottom 14 83.6 27.3 T-15 10/28/22 Tank Pit - Bottom 14 69.6 41.5 D-1 11/21/22 Dispenser 3 1,970 NA D-2 11/21/22 Dispenser 3 265 NA D-3 11/21/22 Dispenser 3 162 NA D-4 11/21/22 Dispenser 3 7.7 J BDL D-5 11/21/22 Dispenser 3 BDL 6.5 J D-6 11/21/22 Dispenser 3 BDL NA D-7 11/21/22 Dispenser 3 BDL BDL PL-1 11/21/22 Product Line 3 4.1 J NA PL-2 11/21/22 Product Line 3 3.5 J NA PL-3 11/21/22 Product Line 3 BDL NA PL-4 11/21/22 Product Line 3 BDL NA PL-5 11/21/22 Product Line 3 7.0 J BDL PL-6 11/21/22 Product Line 3 3.9 J BDL PL-7 11/21/22 Product Line 3 13.7 16.2 PL-8 11/21/22 Product Line 3 1,250 286 Notes: mg/kg – Milligrams per kilogram BDL – Below detection limit TPH – Total petroleum hydrocarbons GRO – Gasoline range organics DRO - Diesel Range Organics NA - Not analyzed 8015C NCDEQ Action Level (mg/kg)TPH-GROTPH-DROEPA Method Contaminant of Concern Page 3 of 4 Table 4-2 Summary of Over-Excavation Soil Sampling Results Speedway Store No. 7940 5729 West Friendly Avenue, Guilford College, North Carolina 27410 Incident Number: TBD Facility Number: 0000023295 Sample ID Date Collected Sample Depth (ft bgs)n-ButylbenzeneIsopropylbenzeneNaphthalenen-propylbenzene240.00725.48 6 0.085 2.4 1.3 0.2 1.4 6.6 6.6 0.44 0.34 0.32 0.17 0.23 0.054 1.5 0.2 68 540 31 540 #31 14,000121,25060.3 3,120 156 782 1,560 5.5 1,560 156 156 312 21 NA 78.2 93.8 22.8 62.5 5.5 625 1,560 469 1,560 31,200 469 210,00059.418,600297 46,700 1,810 11,600 23,300 27 23,300 2,300 2,300 4,670 105 2,330 1,160 1,400 112 934 27 9,340 23,300 7,000 23,300 467,000 7,000 DE-111/4/202215BDL2.228.9135 760 BDL 26.1 18.1 91.5 78.0 540 162 ND ND ND ND ND NA NA NA 9,210 9,390 8,250 NA NA NA DE-211/4/202215BDL0.200.0910.23 1.4 BDL BD.0.034 0.92 0.095 1.1 0.33 0.0083 J 0.036 0.015 ND 0.17 NA NA NA 4.40 J 10.6 14.7 NA NA NA DE-311/4/202215BDL0.0620.0380.016 0.047 0.034 BDL BDL 0.014 BDL 0.012 0.012 0.0054 J 0.080 0.011 0.026 J 0.081 BDL BDL BDL BDL BDL 4.22 J BDL BDL BDL D-111/21/20223BDL0.171.818.0 87.9 0.095 J BDL 2.1 16.2 9.2 68.0 21.2 BDL BDL BDL BDL BDL NA NA NA 191 519 392 NA NA NA PL-8 (RISK)11/21/202230.57 JND0.123.6 5.2 BDL 3.3 1.4 9.9 6.0 38.0 8.1 BDL BDL BDL BDL BDL 3.36 7.15 4.48 125 369 323 73.4 BDL 66.0 Notes: Only analytes with detections are included in the table mg/kg – Milligrams per kilogram VOCs – Volatile organic compounds SVOCs – Semi-volatile organic compounds BDL – Below laboratory detection limit NA - Not Analyzed TPH – Total petroleum hydrocarbons VPH- Volatile Petroleum Hydrocarbons EPH- Extractable Petroleum Hydrocarbons The result reported for C9-C18 Aliphatics is based on available C9-C12 and C9-C18 Aliphatic results The result reported for C9-C22 Aromatics is based on the available C9-C10 and C11-C22 Aromatics results. Bold -Compound detected above Soil to GW MSCC or Action Level Shaded- Compound Exceeded Residential MSCC Red Font - Compound exceded Industrial Commercial MSCC MSCC – Maximum Soil Contaminant Concentration NS- No Standard J-Estimated Value Analytical Method VOCs by EPA 8260 SVOCs by EPA 8270 MADEP VPH Contaminant of Concern C9-C12 AliphaticsMADEP EPH C19-C36 AliphaticsC11-C22 AromaticsSoil to Groundwater MSCC(mg/kg)1-Methylnaphthalene2-MethylnaphthaleneNaphthaleneC5-C8 AliphaticsMethyl-tert-butyl ether1,2,4-Trimethylbenzene1,3,5-Trimethylbenzene2-HexanoneXylenesResidential MSCC (mg/kg) Industrial Commercial MSCC (mg/kg)C9-C10 Aromatic (Unadjusted)C9-C18 AliphaticsAcetoneBenzeneTolueneEthylbenzeneChlorobenzeneChloroformDiisopropyl etherMethylene Chloride Appendix A UST-3 Form – Notice of Intent: UST Permanent Closure or Change in Service UST-3 Notice of Intent: UST Permanent Closure or Change-in-Service Return completed form to: The DWM Regional Office located in the area where the facility is located.Also send a copy to the Central Office in Raleigh. SEE MAP ON THE BACK OF THIS FORM FOR THE CENTRAL AND REGIONAL OFFICE ADDRESSES. STATE USE ONLY I.D. #_____________________ Date Received______________ INSTRUCTIONS (READ THIS FIRST) Complete and return a UST-3 form at least thirty (30) days prior to closure or change-in-service activities. Completed UST closure or change-in-service site assessment reports, along with a copy of the UST-2A and/or 2B forms, should be submitted to the appropriate Division of Waste Management (DWM) Regional Office within thirty (30)days following closure activities. The UST-2 form should also be submitted to the Central Office in Raleigh so that the status of the tanks may be changed to permanently closed and your tank fee account can be closed out.Note: Tank fees may be due for unregistered tanks. UST closure and change-in-service site assessments must be completed in accordance with the latest version of the Guidelines for Site Checks, Tank Closure and Initial Response. The guidelines can be obtained at https://deq.nc.gov/about/divisions/waste-management/ust. Note: To close tanks in place you must obtain prior approval from the DWM Regional office located in the region where the facility is located. You must make sure that USTs removed from your property are disposed of properly. When choosing a closure contractor, ask where the tank(s) will be taken for disposal. Usually, USTs are cleaned and cut up for scrap metal. This is dangerous work and must be performed by a qualified company. Tanks disposed of illegally in fields or other dumpsites can leak petroleum products and sludge into the environment. If your tanks are disposed of improperly, you could be held responsible for the cleanup of any environmental damage that occurs. I. OWNERSHIP OF TANKS II.LOCATION Owner Name (Corporation, Individual, Public Agency, or Other Entity) Speedway LLC Facility Name or Company Speedway #7940 Street Address PO Box 1500 Facility ID # (If known) 00-0-0000023295 City Springfield County Clark Street Address 5729 West Friendly Avenue State OH Zip Code 45501 City Guilford College County Guilford Zip Code 27410 Phone Number 919-268-7176 Email Andrew.McMillan@7-Eleven.com Phone Number III. CONTACT PERSONNEL Name: Andrew McMillan Company Name: Speedway LLC Job Title: Regional Gasoline Environmental Com Phone Number: 919-268-7176 IV. TANK REMOVAL, CLOSURE IN PLACE, CHANGE-IN SERVICE 1.Contact local fire marshal. 2.Plan entire closure event. 3.Conduct Site Soil Assessment. 4.If removing tanks or closing in place, refer to API Publication 2015 Cleaning Petroleum Storage Tanks and 1604 Removal and Disposal of Used Underground Petroleum Storage Tanks. 5.Provide a sketch locating piping, tanks and soil sampling locations. 6.Submit a closure report in the format of UST- 12 (including the form UST-2) within thirty(30) days following the site investigation. 7.If a release from the tanks has occurred, the site assessment portion of the tank closure must be conducted under the supervision of a P.E. or L.G., with all closure site assessment reports bearing the signature and seal of the P.E. or L.G. If a release has not occurred, the supervision, signature or seal of a P.E. or L.G. is not required. 8.Keep closure records for three (3) years. V. WORK TO BE PERFORMED BY Contractor Name: TBD Contractor Company Name: Address:State:Zip Code:Phone No: Primary Consultant Name: Nathan Pinsker Primary Consultant Company Name: AECOM Technical Services, of NC Consultant Phone No: 919-461-1559 VI. TANKS SCHEDULED FOR CLOSURE OR CHANGE-IN-SERVICE Tank ID No.Size in Gallons Last Contents Proposed Activity Closure Change-In-Service Removal Abandonment in Place *New Contents Stored 1 8000 Gasoline, Gas Mix 2 8000 Gasoline, Gas Mix 3 8000 Gasoline, Gas Mix 4 8000 Kerosene 5 8000 Dielsel, Dielsel Mix * Prior written approval to abandon a tank in place must be received from a DWM Regional Office. VII. OWNER OR OWNER’S AUTHORIZED REPRESENTATIVE Has a release from a UST system occurred at this location? Yes No Unknown I understand that I can be held responsible for environmental damage resulting from the improper disposal of my USTs. Print name and official title: Andrew McMillan Regional Gasoline Environmental Compliance Manager Signature Date Signed SCHEDULED REMOVAL DATE 10/26/2022 Notify your DWM Regional Office 48 hours before this date if scheduled removal date changes UST-3 Rev 2/2021 919-268-7176 9/29/2022 Appendix B UST-2A Form – Site Investigation Report for Permanent Closure or Change-in-Service of UST UST-2A Site Investigation Report for Permanent Closure or Change-in- Service of REGISTERED UST Return completed form to: NC DEQ / DWM / UST SECTION 1646 MAIL SERVICE CENTER RALEIGH, NC 27699-1646 ATTN: REGISTRATION & PERMITTING phone (919) 707-8171 fax (919) 715-1117 http://www.wastenotnc.org/ STATE USE ONLY: Facility ID # Date Received INSTRUCTIONS (READ THIS FIRST) 1. UST permanent closure or change in service must be completed in accordance with the latest version of the Guidelines for Site Checks, Tank Closure and Initial Response and Abatement. The guidelines can be obtained at http://deq.nc.gov/about/divisions/waste-management/waste- management-permit-guidance/underground-storage-tanks-section. 2. Permanent closure: Complete all sections of this form. 3. Change-in-service: Where a UST system will be converted from storing a regulated substance to a non-regulated substance, complete sections I, II, III, IV, and VI 4. For more than 5 registered UST systems, attach additional forms as needed 5. Tank Fee Refund: An annual tank fee may be refunded for a tank for which a tank fee was not required. An owner or operator must submit a written request and include: (1) contact information, (2) federal identification # or SSN, and (3) a copy of UST-2 form. The annual tank fee will be prorated based on the date of permanent closure. 6. UNREGISTERED USTs use Form UST-2B I. OWNERSHIP OF TANKS II. LOCATION OF TANKS Owner Name (Corporation, Individual, Public Agency, or Other Entity) Facility Name or Company Street Address Facility ID # (If known) City County Street Address State Zip Code City County Zip Code Phone Number Phone Number III. CONTACT PERSONNEL Contact for Facility: Job Title: Phone #: Closure Contractor Name: Closure Contractor Company: Address: Phone # Primary Consultant Name: Primary Consultant Company: Address: Phone # IV. UST INFORMATION FOR REGISTERED UST SYSTEMS UNREGISTERED USTs use Form UST-2B V. EXCAVATION CONDITION Tank ID No. Size in Gallons Last Contents Last Use Date Permanent Close Date Method of Permanent Closure: Indicate REMOVED or enter fill material, such as foam/ concrete/ sand Change-in- Service Date Water in excavation Free product Notable odor or visible soil contaminatio n Yes No Yes No Yes No VI. CERTIFICATION I certify under penalty of law that I have personally examined and am familiar with the information submitted in this and all attached documents and that based on my inquiry of those individuals immediately responsible for obtaining the information, I believe that the submitted information is true accurate and complete. Signature Date Signed NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY, DIVISION OF WASTE MANAGEMENT, UST SECTION 1646 MAIL SERVICE CENTER, RALEIGH, NC 27699-1646 PHONE (919) 707-8171 FAX (919) 715-1117 http://www.wastenotnc.org/ 1/2016 11/01/2022 Appendix C UST-61 Forms - 24-Hour Release and UST Leak Reporting Form UST-61 24-Hour Release and UST Leak Reporting Form. For Releases in NC This form should be completed and submitted to the UST Section’s regional office following a known or suspected release from an underground storage tank (UST) system. This form is required to be submitted within 24 hours of discovery of a known or suspected release (DWM USE ONLY) Incident # ________ Risk (H,I,L,U)_______ Received On ________ Received By ________ Reported by (circle one): Phone, Fax or Report Region _______ Suspected Contamination? (Y/N) ________ Confirmed GW Contamination? (Y/N) ______ Confirmed Soil Contamination ?(Y/N) ______ Samples Taken?(Y/N) ______ Free Product? (Y/N) _____ If Yes, State Greatest Thickness ______________ Facility ID Number ______________ Date Leak Discovered ___________ Comm/Non-Commercial? ________ Reg/Non-regulated? _____________ INCIDENT DESCRIPTION Incident Name: Address: County: City/Town: Zip Code: Regional Office (circle one): Asheville, Mooresville, Fayetteville, Raleigh, Washington, Wilmington, Winston-Salem Latitude (decimal degrees): Longitude (decimal degrees) : Obtained by: Briefly describe suspected or confirmed release: (including but not limited to: nature of release, date of release, amount of release, amount of free product present and recovery efforts, initial responses conducted, impacts to receptors)  GPS  Topographic map  GIS Address matching  Other  Unknown Describe location: HOW RELEASE WAS DISCOVERED (Release Code) (Check one)  Release Detection Equipment or Methods  During UST Closure/Removal  Property Transfer  Visual/Odor  Water in Tank  Water Supply Well Contamination  Groundwater Contamination  Surface Water Contamination  Other (specify) _______________ SOURCE OF CONTAMINATION Source of Release (Check primary source) Cause of Release (Check primary cause) Type of Release (Check one) Product Type Released (Check primary product type released)  Tank  Piping  Dispenser  Submersible Turbine Pump  Delivery Problem  Spill Bucket  Other  Unknown Definitions presented on reverse  Spill  Overfill  Corrosion  Physical/Mechanical Damage  Install Problem  Other  Unknown Definitions presented on reverse  Petroleum  Non-Petroleum  Both Location (Check one)  Facility  Residence  Other  Gasoline/ Diesel/ Kerosene  Heating Oil  Other Petroleum Products  Metals  Other Inorganics  Other Organics  Diesel/Veg. Oil Blend  Vegetable Oil 100%  E10 – E20  E21 – E84  E85 – E99  Ethanol 100%  E01 – E09 Ownership 1. Municipal 2. Military 3. Unknown 4. Private 5. Federal 6. County 7. State Operation Type 1. Public Service 2. Agricultural 3. Residential 4. Education/Relig. 5. Industrial 6. Commercial 7. Mining UST Form 61 (02/19) Page 1 of 2 Y 23295 Y Comm N 11/15/2022 Y Reg Speedway 7940 5729 West Friendly Avenue Guilford College 27410 Guilford TPH closure samples exceed the NCDEQ action limit. Tank basin 36.089407 -79.888397 Risk based samples were collected following excavation to compare to residential and commercial standards as this site has a deed restriction. IMPACT ON DRINKING WATER SUPPLIES Water Supply Wells Affected? 1. Yes 2. No 3. Unknown Number of Water Supply Wells Affected __________________ Water Supply Wells Contaminated: (Include Users Names, Addresses and Phone Numbers. Attach additional sheet if necessary) 1. 2. 3. UST SYSTEM OWNER UST Owner/Company Point of Contact Address City State Zip Code Telephone Number UST SYSTEM OPERATOR UST Operator/Company Address City State Zip Code Telephone Number LANDOWNER AT LOCATION OF UST INCIDENT Landowner Address City State Zip Code Telephone Number Draw Sketch of Area (showing two major road intersections) or Attach Map Person Reporting Incident Company Telephone Number Title Address Date UST Form 61 (02/19) Page 2 of 2 Definitions of Sources Tank: means the tank that stores the product and is part of the underground storage tank system Piping: means the piping and connectors running from the tank or submersible turbine pump to the dispenser or other end-use equipment (Vent, vapor recovery, or fill lines are excluded.) Dispenser: includes the dispenser and the equipment used to connect the dispenser to the piping (e.g., a release from a suction pump or from components located above the shear valve) Submersible Turbine Pump (STP) Area includes the submersible turbine pump head (typically located in the tank sump), the line leak detector, and the piping that connects the submersible turbine pump to the tank Delivery Problem: identifies releases that occurred during product delivery to the tank. (Typical causes associated with this source are spills and overfills.) Other: serves as the option to use when the release source is known but does not fit into one of the preceding categories (e.g., for releases from vent lines, vapor recovery lines, and fill lines) Unknown: identifies releases for which the source has not been determined Definitions of Causes Spill: use this cause when a spill occurs (e.g., when the delivery hose is disconnected from the tank fill pipe or when the nozzle is removed from the dispenser) Overfill: use when an overfill occurs (e.g., overfills may occur from the fill pipe at the tank or when the nozzle fails to shut off at the dispenser) Physical or Mechanical Damage: use for all types of physical or mechanical damage, except corrosion (e.g., puncture of tank or piping, loose fittings, broken components, and components that have changed dimension) Corrosion: use when a metal tank, piping, or other component has a release due to corrosion (e.g., for steel, corrosion takes the form of rust) Installation Problem: use when the problem is determined to have occurred specifically because the UST system was not installed properly Other: use this option when the cause is known but does not fit into one of the preceding categories (e.g., putting regulated substances into monitoring wells) Unknown: use when the cause has not been determined Speedway LLC Samuel Kramer Same as system owner PO Box 1500 Springfield OH 45501 Same as system owner Nathan Pinsker AECOM Technical Services of North Carolina, Inc 919-461-1559 Project Manager 5438 Wade Park Boulevard, Suite 200, Raleigh, NC 27607 11/15/2022 Three closure samples per tank Dispenser sampleand one product line sample. Six dispenser samples Product line layout unknown. Estimated 10 samples for every ten feet, connection, or turn Appendix D Liquid Disposal Manifests Appendix E Fire Marshall Report Greensboro Fire and Life Safety Division Inspection Summary 1512 N Church Street Greensboro, NC 27405 5729 W FRIENDLY AV Greensboro, NC 27410 SPEEDWAY Responsible Party Paradis, Carter 5438 Wade Park Blvd Raleigh, NC 27607 Inspected Property Contact: Address: Business: Address: Phone:919-619-7169 Email:carter.paradis@aecom.com $150 For questions about your inspection or other fire code inquiries, please contact your Fire Inspector by the email or phone number listed above. Or you may contact the Greensboro Fire and Life Safety Division by calling (336)373-2177. Inspection Information: Inspection Violations: Fee: Inspection Type:1D - UST/AST Removal Inspection & Permit Inspection Date: Fire Inspector: Fire Inspector Email: Fire Inspector Phone: This inspection revealed no violations. 1Page10/28/2022 12:22 OccID: 199904598 InspectID: _6G60YRGVI Greensboro Fire and Life Safety Division Inspection Summary 1512 N Church Street Greensboro, NC 27405 Summary of Charges: $150Inspection Fees: $0Violation Fines: $150 The Greensboro Fire and Life Safety Division has contracted with Fire Recovery USA to provide electronic invoicing and collections. Inspection notices and invoices will be electronically delivered and tracked to the email address you provide the fire inspector. Business owners without email addresses will still receive their bills through traditional mail. You will have the option of several payment methods. Please follow the instructions provided in your emailed invoice. For invoicing and payment inquiries, you may contact Fire Recovery USA at (888) 640-7222, ext. 103. Total Charges: Permits linked to this Inspection: Permit Fees: $0 There is no permit linked to this inspection. 2Page10/28/2022 12:22 OccID: 199904598 InspectID: _6G60YRGVI Appendix F UST Disposal Certification Appendix G Photographic Log PHOTOGRAPHIC LOG Client Name: 7-Eleven,Inc. Site Location:Speedway Store #7940 5729 West Friendly Avenue, Guilford College,North Carolina Project No. 60687379 Photo No. 1 Date: 10/28/22 Direction Photo Taken: NA Description: View of 8,000-gallon kerosene UST #4 removed from tank pit. Photo No. 2 Date: 10/28/22 Direction Photo Taken: Southwest Description: View of 8,000-gallon DSL UST #5 8,000- gallon RUL UST #1 and RUL UST #2,and 8,000-gallon PUL UST #3 exposed in tank pit prior to their removal. PHOTOGRAPHIC LOG Client Name: 7-Eleven,Inc. Site Location:Speedway Store #7940 5729 West Friendly Avenue, Guilford College,North Carolina Project No. 60687379 Photo No. 3 Date: 10/28/22 Direction Photo Taken: N/A Description: View of 8,000-gallon kerosene UST #4 (identified as T-1 during removal activities)on roll-off prior to transportation and disposal off-site. Photo No. 4 Date: 10/28/22 Direction Photo Taken: Southwest Description: View of 8,000-gallon PUL UST #3 in the process of being removed from tank pit. PHOTOGRAPHIC LOG Client Name: 7-Eleven,Inc. Site Location:Speedway Store #7940 5729 West Friendly Avenue, Guilford College,North Carolina Project No. 60687379 Photo No. 5 Date: 10/28/22 Direction Photo Taken: N/A Description: View of 8,000-gallon PUL UST #3 (identified as T-2 during removal activities)on roll-off prior to transportation and disposal off-site. Photo No. 6 Date: 10/28/22 Direction Photo Taken: N/A Description: View of 8,000-gallon RUL UST #2 in the process of being removed from tank pit. PHOTOGRAPHIC LOG Client Name: 7-Eleven,Inc. Site Location:Speedway Store #7940 5729 West Friendly Avenue, Guilford College,North Carolina Project No. 60687379 Photo No. 7 Date: 10/28/22 Direction Photo Taken: NA Description: View of 8,000-gallon RUL UST #2 (identified as T-3 during removal activities)removed from tank pit. Photo No. 8 Date: 10/28/22 Direction Photo Taken: NA Description: View of 8,000-gallon RUL UST #1 in the process of being removed from tank pit. PHOTOGRAPHIC LOG Client Name: 7-Eleven,Inc. Site Location:Speedway Store #7940 5729 West Friendly Avenue, Guilford College,North Carolina Project No. 60687379 Photo No. 9 Date: 10/28/22 Direction Photo Taken: N/A Description: View of 8,000-gallon RUL UST #1 (identified as T-4 during removal activities)on roll-off prior to transportation and disposal off-site. Photo No. 10 Date: 10/28/22 Direction Photo Taken: South Description: View of 8,000-gallon DSL UST #5 in the process of being removed from tank pit. PHOTOGRAPHIC LOG Client Name: 7-Eleven,Inc. Site Location:Speedway Store #7940 5729 West Friendly Avenue, Guilford College,North Carolina Project No. 60687379 Photo No. 11 Date: 10/28/22 Direction Photo Taken: N/A Description: View of 8,000-gallon DSL UST #5 removed from ground. Photo No. 12 Date: 10/28/22 Direction Photo Taken: South Description: View of tank pit after USTs have been removed. PHOTOGRAPHIC LOG Client Name: 7-Eleven,Inc. Site Location:Speedway Store #7940 5729 West Friendly Avenue, Guilford College,North Carolina Project No. 60687379 Photo No. 13 Date: 11/4/22 Direction Photo Taken: N/A Description: View of shoring in preparation for the installation of the new USTs. Photo No. 14 Date: 11/21/22 Direction Photo Taken: South Description: View product line trench and dispenser sump excavation areas. PHOTOGRAPHIC LOG Client Name: 7-Eleven,Inc. Site Location:Speedway Store #7940 5729 West Friendly Avenue, Guilford College,North Carolina Project No. 60687379 Photo No. 15 Date: 11/21/22 Direction Photo Taken: East Description: View pipeline trench and dispenser sump excavation areas. Appendix H Soil Disposal Manifests Appendix I Laboratory Reports #=CL# November 09, 2022 LIMS USE: FR - NATHAN PINSKER LIMS OBJECT ID: 92634020 92634020 Project: Pace Project No.: RE: Nathan Pinsker AECOM 5438 Wade Park Blvd Suite 200 Raleigh, NC 27607 SPEEDWAY 7940 Dear Nathan Pinsker: Enclosed are the analytical results for sample(s) received by the laboratory on November 01, 2022. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Bonnie Vang bonnie.vang@pacelabs.com Project Manager (704)875-9092 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 36 #=CP# CERTIFICATIONS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Pace Analytical Services Charlotte South Carolina Laboratory ID: 99006 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Laboratory ID: 99006 South Carolina Certification #: 99006001 South Carolina Drinking Water Cert. #: 99006003 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana DoH Drinking Water #: LA029 Virginia/VELAP Certification #: 460221 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 36 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92634020 SPEEDWAY 7940 Lab ID Sample ID Matrix Date Collected Date Received 92634020001 T-01 Solid 10/28/22 10:00 11/01/22 12:55 92634020002 T-02 Solid 10/28/22 10:05 11/01/22 12:55 92634020003 T-03 Solid 10/28/22 10:15 11/01/22 12:55 92634020004 T-04 Solid 10/28/22 10:20 11/01/22 12:55 92634020005 T-05 Solid 10/28/22 10:30 11/01/22 12:55 92634020006 T-06 Solid 10/28/22 10:35 11/01/22 12:55 92634020007 T-07 Solid 10/28/22 11:10 11/01/22 12:55 92634020008 T-08 Solid 10/28/22 11:05 11/01/22 12:55 92634020009 T-09 Solid 10/28/22 11:00 11/01/22 12:55 92634020010 T-10 Solid 10/28/22 11:30 11/01/22 12:55 92634020011 T-11 Solid 10/28/22 11:25 11/01/22 12:55 92634020012 T-12 Solid 10/28/22 11:20 11/01/22 12:55 92634020013 T-13 Solid 10/28/22 12:40 11/01/22 12:55 92634020014 T-14 Solid 10/28/22 12:30 11/01/22 12:55 92634020015 T-15 Solid 10/28/22 12:25 11/01/22 12:55 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 36 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92634020 SPEEDWAY 7940 Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92634020001 T-01 EPA 8015C 2 PASI-CAP2 EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92634020002 T-02 EPA 8015C 2 PASI-CAP2 EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92634020003 T-03 EPA 8015C 2 PASI-CAP2 EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92634020004 T-04 EPA 8015C 2 PASI-CCL SW-846 1 PASI-CKDF 92634020005 T-05 EPA 8015C 2 PASI-CCL SW-846 1 PASI-CKDF 92634020006 T-06 EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92634020007 T-07 EPA 8015C 2 PASI-CCL SW-846 1 PASI-CKDF 92634020008 T-08 EPA 8015C 2 PASI-CCL SW-846 1 PASI-CKDF 92634020009 T-09 EPA 8015C 2 PASI-CCL SW-846 1 PASI-CKDF 92634020010 T-10 EPA 8015C 2 PASI-CCL SW-846 1 PASI-CKDF 92634020011 T-11 EPA 8015C 2 PASI-CCL SW-846 1 PASI-CKDF 92634020012 T-12 EPA 8015C 2 PASI-CCL SW-846 1 PASI-CKDF 92634020013 T-13 EPA 8015C 2 PASI-CAP2 EPA 8015C 2 PASI-CCL SW-846 1 PASI-CKDF 92634020014 T-14 EPA 8015C 2 PASI-CAP2 EPA 8015C 2 PASI-CCL SW-846 1 PASI-CKDF 92634020015 T-15 EPA 8015C 2 PASI-CAP2 EPA 8015C 2 PASI-CCL SW-846 1 PASI-CKDF REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 36 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92634020 SPEEDWAY 7940 Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 36 #=HO# SUMMARY OF DETECTION Pace Project No.: Project: 92634020 SPEEDWAY 7940 Parameters AnalyzedResult Lab Sample ID Report Limit QualifiersUnitsMethod Client Sample ID 92634020001 T-01 Diesel Range Organics(C10-C28)7.1 mg/kg 11/09/22 08:515.3EPA 8015C Percent Moisture 5.2 %11/01/22 17:35 N20.10SW-846 92634020002 T-02 Diesel Range Organics(C10-C28)4.0J mg/kg 11/09/22 08:515.2EPA 8015C Percent Moisture 4.0 %11/01/22 17:35 N20.10SW-846 92634020003 T-03 Diesel Range Organics(C10-C28)437 mg/kg 11/09/22 11:5610.7EPA 8015C Gas Range Organics (C6-C10)38.3 mg/kg 11/02/22 19:403.6EPA 8015C Percent Moisture 6.1 %11/01/22 17:35 N20.10SW-846 92634020004 T-04 Gas Range Organics (C6-C10)7890 mg/kg 11/03/22 23:04120EPA 8015C Percent Moisture 32.7 %11/01/22 17:35 N20.10SW-846 92634020005 T-05 Gas Range Organics (C6-C10)70.4 mg/kg 11/03/22 14:3010.7EPA 8015C Percent Moisture 25.5 %11/01/22 17:35 N20.10SW-846 92634020006 T-06 Gas Range Organics (C6-C10)4100 mg/kg 11/05/22 09:32109EPA 8015C Percent Moisture 28.1 %11/01/22 17:35 N20.10SW-846 92634020007 T-07 Gas Range Organics (C6-C10)604 mg/kg 11/03/22 15:2115.6EPA 8015C Percent Moisture 29.6 %11/01/22 17:35 N20.10SW-846 92634020008 T-08 Gas Range Organics (C6-C10)15500 mg/kg 11/04/22 05:55387EPA 8015C Percent Moisture 36.1 %11/01/22 17:36 N20.10SW-846 92634020009 T-09 Gas Range Organics (C6-C10)159 mg/kg 11/04/22 02:5512.4EPA 8015C Percent Moisture 31.1 %11/01/22 17:36 N20.10SW-846 92634020010 T-10 Gas Range Organics (C6-C10)17700 mg/kg 11/04/22 05:03251EPA 8015C Percent Moisture 29.8 %11/01/22 17:36 N20.10SW-846 92634020011 T-11 Gas Range Organics (C6-C10)6160 mg/kg 11/04/22 04:38123EPA 8015C Percent Moisture 30.2 %11/01/22 17:36 N20.10SW-846 92634020012 T-12 Gas Range Organics (C6-C10)11800 mg/kg 11/04/22 05:29178EPA 8015C Percent Moisture 31.0 %11/01/22 17:36 N20.10SW-846 92634020013 T-13 Diesel Range Organics(C10-C28)1050 mg/kg 11/09/22 11:5629.7EPA 8015C Gas Range Organics (C6-C10)4670 mg/kg 11/04/22 04:1264.3EPA 8015C Percent Moisture 31.9 %11/01/22 18:20 N20.10SW-846 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 36 #=HO# SUMMARY OF DETECTION Pace Project No.: Project: 92634020 SPEEDWAY 7940 Parameters AnalyzedResult Lab Sample ID Report Limit QualifiersUnitsMethod Client Sample ID 92634020014 T-14 Diesel Range Organics(C10-C28)27.3 mg/kg 11/09/22 09:247.4EPA 8015C Gas Range Organics (C6-C10)83.6 mg/kg 11/04/22 03:2112.0EPA 8015C Percent Moisture 31.4 %11/01/22 18:20 N20.10SW-846 92634020015 T-15 Diesel Range Organics(C10-C28)41.5 mg/kg 11/09/22 09:417.1EPA 8015C Gas Range Organics (C6-C10)69.6 mg/kg 11/04/22 03:4610.1EPA 8015C Percent Moisture 29.2 %11/01/22 18:20 N20.10SW-846 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-01 Lab ID:92634020001 Collected:10/28/22 10:00 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)7.1 mg/kg 11/09/22 08:5111/08/22 11:175.3 3.8 1 Surrogates n-Pentacosane (S)66 %11/09/22 08:51 629-99-211/08/22 11:1710-130 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)ND mg/kg 11/02/22 18:4911/02/22 11:313.4 0.95 1 Surrogates 4-Bromofluorobenzene (S)94 %11/02/22 18:49 460-00-411/02/22 11:3166-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 5.2 %11/01/22 17:35 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-02 Lab ID:92634020002 Collected:10/28/22 10:05 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)4.0J mg/kg 11/09/22 08:5111/08/22 11:175.2 3.7 1 Surrogates n-Pentacosane (S)61 %11/09/22 08:51 629-99-211/08/22 11:1710-130 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)ND mg/kg 11/02/22 19:1511/02/22 11:313.5 0.97 1 Surrogates 4-Bromofluorobenzene (S)92 %11/02/22 19:15 460-00-411/02/22 11:3166-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 4.0 %11/01/22 17:35 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-03 Lab ID:92634020003 Collected:10/28/22 10:15 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)437 mg/kg 11/09/22 11:5611/08/22 11:1710.7 7.6 2 Surrogates n-Pentacosane (S)80 %11/09/22 11:56 629-99-211/08/22 11:1710-130 2 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)38.3 mg/kg 11/02/22 19:4011/02/22 11:313.6 1.0 1 Surrogates 4-Bromofluorobenzene (S)134 %11/02/22 19:40 460-00-4 S511/02/22 11:3166-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 6.1 %11/01/22 17:35 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-04 Lab ID:92634020004 Collected:10/28/22 10:20 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)7890 mg/kg 11/03/22 23:0411/03/22 10:0812033.3 10 Surrogates 4-Bromofluorobenzene (S)121 %11/03/22 23:04 460-00-411/03/22 10:0866-130 10 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 32.7 %11/01/22 17:35 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-05 Lab ID:92634020005 Collected:10/28/22 10:30 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)70.4 mg/kg 11/03/22 14:3011/03/22 10:0810.7 3.0 1 Surrogates 4-Bromofluorobenzene (S)108 %11/03/22 14:30 460-00-411/03/22 10:0866-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 25.5 %11/01/22 17:35 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-06 Lab ID:92634020006 Collected:10/28/22 10:35 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)4100 mg/kg 11/05/22 09:3211/04/22 15:0510930.3 10 Surrogates 4-Bromofluorobenzene (S)125 %11/05/22 09:32 460-00-411/04/22 15:0566-130 10 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 28.1 %11/01/22 17:35 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-07 Lab ID:92634020007 Collected:10/28/22 11:10 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)604 mg/kg 11/03/22 15:2111/03/22 10:0815.6 4.3 1 Surrogates 4-Bromofluorobenzene (S)146 %11/03/22 15:21 460-00-4 S211/03/22 10:0866-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 29.6 %11/01/22 17:35 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-08 Lab ID:92634020008 Collected:10/28/22 11:05 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)15500 mg/kg 11/04/22 05:5511/03/22 10:1338710725 Surrogates 4-Bromofluorobenzene (S)99 %11/04/22 05:55 460-00-411/03/22 10:1366-130 25 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 36.1 %11/01/22 17:36 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 15 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-09 Lab ID:92634020009 Collected:10/28/22 11:00 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)159 mg/kg 11/04/22 02:5511/03/22 10:1312.4 3.4 1 Surrogates 4-Bromofluorobenzene (S)106 %11/04/22 02:55 460-00-411/03/22 10:1366-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 31.1 %11/01/22 17:36 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 16 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-10 Lab ID:92634020010 Collected:10/28/22 11:30 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)17700 mg/kg 11/04/22 05:0311/03/22 10:1325169.5 12.5 Surrogates 4-Bromofluorobenzene (S)122 %11/04/22 05:03 460-00-411/03/22 10:1366-130 12.5 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 29.8 %11/01/22 17:36 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 17 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-11 Lab ID:92634020011 Collected:10/28/22 11:25 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)6160 mg/kg 11/04/22 04:3811/03/22 10:1312333.9 10 Surrogates 4-Bromofluorobenzene (S)112 %11/04/22 04:38 460-00-411/03/22 10:1366-130 10 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 30.2 %11/01/22 17:36 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 18 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-12 Lab ID:92634020012 Collected:10/28/22 11:20 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)11800 mg/kg 11/04/22 05:2911/03/22 10:1317849.3 12.5 Surrogates 4-Bromofluorobenzene (S)118 %11/04/22 05:29 460-00-411/03/22 10:1366-130 12.5 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 31.0 %11/01/22 17:36 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 19 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-13 Lab ID:92634020013 Collected:10/28/22 12:40 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)1050 mg/kg 11/09/22 11:5611/08/22 11:1729.7 21.1 4 Surrogates n-Pentacosane (S)63 %11/09/22 11:56 629-99-211/08/22 11:1710-130 4 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)4670 mg/kg 11/04/22 04:1211/03/22 10:1364.3 17.8 5 Surrogates 4-Bromofluorobenzene (S)132 %11/04/22 04:12 460-00-4 S511/03/22 10:1366-130 5 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 31.9 %11/01/22 18:20 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 20 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-14 Lab ID:92634020014 Collected:10/28/22 12:30 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)27.3 mg/kg 11/09/22 09:2411/08/22 11:177.4 5.2 1 Surrogates n-Pentacosane (S)67 %11/09/22 09:24 629-99-211/08/22 11:1710-130 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)83.6 mg/kg 11/04/22 03:2111/03/22 10:1312.0 3.3 1 Surrogates 4-Bromofluorobenzene (S)104 %11/04/22 03:21 460-00-411/03/22 10:1366-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 31.4 %11/01/22 18:20 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 21 of 36 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92634020 SPEEDWAY 7940 Sample:T-15 Lab ID:92634020015 Collected:10/28/22 12:25 Received:11/01/22 12:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)41.5 mg/kg 11/09/22 09:4111/08/22 11:177.1 5.1 1 Surrogates n-Pentacosane (S)66 %11/09/22 09:41 629-99-211/08/22 11:1710-130 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)69.6 mg/kg 11/04/22 03:4611/03/22 10:1310.1 2.8 1 Surrogates 4-Bromofluorobenzene (S)105 %11/04/22 03:46 460-00-411/03/22 10:1366-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 29.2 %11/01/22 18:20 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 22 of 36 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92634020 SPEEDWAY 7940 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 734314 EPA 5030B EPA 8015C Gasoline Range Organics Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92634020001, 92634020002, 92634020003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3821646 Associated Lab Samples:92634020001, 92634020002, 92634020003 Matrix:Solid AnalyzedMDL Gas Range Organics (C6-C10)mg/kg ND 6.0 11/02/22 14:061.7 4-Bromofluorobenzene (S)%93 66-130 11/02/22 14:06 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3821647LABORATORY CONTROL SAMPLE: LCSSpike Gas Range Organics (C6-C10)mg/kg 42.850.4 85 70-130 4-Bromofluorobenzene (S)%95 66-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3821649MATRIX SPIKE SAMPLE: MSSpike Result 92633605002 Gas Range Organics (C6-C10)mg/kg 215128 89 65-146102 4-Bromofluorobenzene (S)%112 66-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92633164001 3821648SAMPLE DUPLICATE: Gas Range Organics (C6-C10)mg/kg ND 30ND 4-Bromofluorobenzene (S)%9392 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 23 of 36 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92634020 SPEEDWAY 7940 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 734604 EPA 5030B EPA 8015C Gasoline Range Organics Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92634020004, 92634020005, 92634020007 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3823248 Associated Lab Samples:92634020004, 92634020005, 92634020007 Matrix:Solid AnalyzedMDL Gas Range Organics (C6-C10)mg/kg ND 6.0 11/03/22 14:041.7 4-Bromofluorobenzene (S)%93 66-130 11/03/22 14:04 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3823249LABORATORY CONTROL SAMPLE: LCSSpike Gas Range Organics (C6-C10)mg/kg 50.450.2 100 70-130 4-Bromofluorobenzene (S)%95 66-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3823251MATRIX SPIKE SAMPLE: MSSpike Result 92634020007 Gas Range Organics (C6-C10)mg/kg 793130 145 65-146604 4-Bromofluorobenzene (S)%S215466-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92634020005 3823250SAMPLE DUPLICATE: Gas Range Organics (C6-C10)mg/kg 72.6 3 3070.4 4-Bromofluorobenzene (S)%104108 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 24 of 36 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92634020 SPEEDWAY 7940 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 734609 EPA 5030B EPA 8015C Gasoline Range Organics Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92634020008, 92634020009, 92634020010, 92634020011, 92634020012, 92634020013, 92634020014, 92634020015 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3823271 Associated Lab Samples:92634020008, 92634020009, 92634020010, 92634020011, 92634020012, 92634020013, 92634020014, 92634020015 Matrix:Solid AnalyzedMDL Gas Range Organics (C6-C10)mg/kg ND 6.0 11/03/22 13:381.7 4-Bromofluorobenzene (S)%94 66-130 11/03/22 13:38 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3823272LABORATORY CONTROL SAMPLE: LCSSpike Gas Range Organics (C6-C10)mg/kg 49.250.2 98 70-130 4-Bromofluorobenzene (S)%94 66-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3823274MATRIX SPIKE SAMPLE: MSSpike Result 92633504005 Gas Range Organics (C6-C10)mg/kg 11871.4 120 65-14632.4 4-Bromofluorobenzene (S)%102 66-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92633504003 3823273SAMPLE DUPLICATE: Gas Range Organics (C6-C10)mg/kg 7.8 6 308.2 4-Bromofluorobenzene (S)%9896 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 25 of 36 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92634020 SPEEDWAY 7940 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 735032 EPA 5030B EPA 8015C Gasoline Range Organics Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92634020006 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3825723 Associated Lab Samples:92634020006 Matrix:Solid AnalyzedMDL Gas Range Organics (C6-C10)mg/kg ND 6.0 11/04/22 14:151.7 4-Bromofluorobenzene (S)%94 66-130 11/04/22 14:15 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3825724LABORATORY CONTROL SAMPLE: LCSSpike Gas Range Organics (C6-C10)mg/kg 47.150 94 70-130 4-Bromofluorobenzene (S)%95 66-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3825726MATRIX SPIKE SAMPLE: MSSpike Result 92634751022 Gas Range Organics (C6-C10)mg/kg 71.177.8 91 65-146ND 4-Bromofluorobenzene (S)%97 66-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92634751019 3825725SAMPLE DUPLICATE: Gas Range Organics (C6-C10)mg/kg ND 30ND 4-Bromofluorobenzene (S)%9494 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 26 of 36 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92634020 SPEEDWAY 7940 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 735486 EPA 3546 EPA 8015C 8015 Solid GCSV Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92634020001, 92634020002, 92634020003, 92634020013, 92634020014, 92634020015 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3827804 Associated Lab Samples:92634020001, 92634020002, 92634020003, 92634020013, 92634020014, 92634020015 Matrix:Solid AnalyzedMDL Diesel Range Organics(C10-C28)mg/kg ND 5.0 11/09/22 08:343.5 n-Pentacosane (S)%58 10-130 11/09/22 08:34 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3827805LABORATORY CONTROL SAMPLE: LCSSpike Diesel Range Organics(C10-C28)mg/kg 39.966.9 60 44-130 n-Pentacosane (S)%69 10-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3827806MATRIX SPIKE SAMPLE: MSSpike Result 92634020014 Diesel Range Organics(C10-C28)mg/kg 85.697.6 60 10-13027.3 n-Pentacosane (S)%65 10-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92634020015 3827807SAMPLE DUPLICATE: Diesel Range Organics(C10-C28)mg/kg 35.5 16 3041.5 n-Pentacosane (S)%6666 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 27 of 36 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92634020 SPEEDWAY 7940 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 734145 SW-846 SW-846 Dry Weight/Percent Moisture Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92634020001, 92634020002, 92634020003, 92634020004, 92634020005, 92634020006, 92634020007, 92634020008, 92634020009, 92634020010, 92634020011, 92634020012 Parameter Units Dup Result Max RPD QualifiersRPDResult 92633710012 3821078SAMPLE DUPLICATE: Percent Moisture %24.4 N222525.0 Parameter Units Dup Result Max RPD QualifiersRPDResult 92633732001 3821079SAMPLE DUPLICATE: Percent Moisture %22.5 N222522.9 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 28 of 36 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92634020 SPEEDWAY 7940 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 734158 SW-846 SW-846 Dry Weight/Percent Moisture Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92634020013, 92634020014, 92634020015 Parameter Units Dup Result Max RPD QualifiersRPDResult 92634077004 3821162SAMPLE DUPLICATE: Percent Moisture %34.4 N222533.5 Parameter Units Dup Result Max RPD QualifiersRPDResult 92633731001 3821163SAMPLE DUPLICATE: Percent Moisture %14.9 N232514.5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 29 of 36 #=QL# QUALIFIERS Pace Project No.: Project: 92634020 SPEEDWAY 7940 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS The lab does not hold NELAC/TNI accreditation for this parameter but other accreditations/certifications may apply. A complete list of accreditations/certifications is available upon request.N2 Surrogate recovery outside laboratory control limits due to matrix interferences (confirmed by similar results from sample re-analysis).S2 Surrogate recovery outside control limits due to matrix interferences (not confirmed by re-analysis).S5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 30 of 36 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92634020 SPEEDWAY 7940 Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92634020001 735486 735790T-01 EPA 3546 EPA 8015C 92634020002 735486 735790T-02 EPA 3546 EPA 8015C 92634020003 735486 735790T-03 EPA 3546 EPA 8015C 92634020013 735486 735790T-13 EPA 3546 EPA 8015C 92634020014 735486 735790T-14 EPA 3546 EPA 8015C 92634020015 735486 735790T-15 EPA 3546 EPA 8015C 92634020001 734314 734356T-01 EPA 5030B EPA 8015C 92634020002 734314 734356T-02 EPA 5030B EPA 8015C 92634020003 734314 734356T-03 EPA 5030B EPA 8015C 92634020004 734604 734664T-04 EPA 5030B EPA 8015C 92634020005 734604 734664T-05 EPA 5030B EPA 8015C 92634020006 735032 735091T-06 EPA 5030B EPA 8015C 92634020007 734604 734664T-07 EPA 5030B EPA 8015C 92634020008 734609 734665T-08 EPA 5030B EPA 8015C 92634020009 734609 734665T-09 EPA 5030B EPA 8015C 92634020010 734609 734665T-10 EPA 5030B EPA 8015C 92634020011 734609 734665T-11 EPA 5030B EPA 8015C 92634020012 734609 734665T-12 EPA 5030B EPA 8015C 92634020013 734609 734665T-13 EPA 5030B EPA 8015C 92634020014 734609 734665T-14 EPA 5030B EPA 8015C 92634020015 734609 734665T-15 EPA 5030B EPA 8015C 92634020001 734145T-01 SW-846 92634020002 734145T-02 SW-846 92634020003 734145T-03 SW-846 92634020004 734145T-04 SW-846 92634020005 734145T-05 SW-846 92634020006 734145T-06 SW-846 92634020007 734145T-07 SW-846 92634020008 734145T-08 SW-846 92634020009 734145T-09 SW-846 92634020010 734145T-10 SW-846 92634020011 734145T-11 SW-846 92634020012 734145T-12 SW-846 92634020013 734158T-13 SW-846 92634020014 734158T-14 SW-846 92634020015 734158T-15 SW-846 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/09/2022 01:41 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 31 of 36 Page 32 of 36 Page 33 of 36 Page 34 of 36 Page 35 of 36 Page 36 of 36 #=CL# November 18, 2022 LIMS USE: FR - NATHAN PINSKER LIMS OBJECT ID: 92635127 92635127 Project: Pace Project No.: RE: Nathan Pinsker AECOM 5438 Wade Park Blvd Suite 200 Raleigh, NC 27607 44682-7940 Guilford College Dear Nathan Pinsker: Enclosed are the analytical results for sample(s) received by the laboratory on November 07, 2022. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace National - Mt. Juliet • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Bonnie Vang bonnie.vang@pacelabs.com Project Manager (704)875-9092 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 49 #=CP# CERTIFICATIONS Pace Project No.: Project: 92635127 44682-7940 Guilford College Pace Analytical Services National 12065 Lebanon Road, Mt. Juliet, TN 37122 Alabama Certification #: 40660 Alaska Certification 17-026 Arizona Certification #: AZ0612 Arkansas Certification #: 88-0469 California Certification #: 2932 Canada Certification #: 1461.01 Colorado Certification #: TN00003 Connecticut Certification #: PH-0197 DOD Certification: #1461.01 EPA# TN00003 Florida Certification #: E87487 Georgia DW Certification #: 923 Georgia Certification: NELAP Idaho Certification #: TN00003 Illinois Certification #: 200008 Indiana Certification #: C-TN-01 Iowa Certification #: 364 Kansas Certification #: E-10277 Kentucky UST Certification #: 16 Kentucky Certification #: 90010 Louisiana Certification #: AI30792 Louisiana DW Certification #: LA180010 Maine Certification #: TN0002 Maryland Certification #: 324 Massachusetts Certification #: M-TN003 Michigan Certification #: 9958 Minnesota Certification #: 047-999-395 Mississippi Certification #: TN00003 Missouri Certification #: 340 Montana Certification #: CERT0086 Nebraska Certification #: NE-OS-15-05 Nevada Certification #: TN-03-2002-34 New Hampshire Certification #: 2975 New Jersey Certification #: TN002 New Mexico DW Certification New York Certification #: 11742 North Carolina Aquatic Toxicity Certification #: 41 North Carolina Drinking Water Certification #: 21704 North Carolina Environmental Certificate #: 375 North Dakota Certification #: R-140 Ohio VAP Certification #: CL0069 Oklahoma Certification #: 9915 Oregon Certification #: TN200002 Pennsylvania Certification #: 68-02979 Rhode Island Certification #: LAO00356 South Carolina Certification #: 84004 South Dakota Certification Tennessee DW/Chem/Micro Certification #: 2006 Texas Certification #: T 104704245-17-14 Texas Mold Certification #: LAB0152 USDA Soil Permit #: P330-15-00234 Utah Certification #: TN00003 Virginia Certification #: VT2006 Vermont Dept. of Health: ID# VT-2006 Virginia Certification #: 460132 Washington Certification #: C847 West Virginia Certification #: 233 Wisconsin Certification #: 998093910 Wyoming UST Certification #: via A2LA 2926.01 A2LA-ISO 17025 Certification #: 1461.01 A2LA-ISO 17025 Certification #: 1461.02 AIHA-LAP/LLC EMLAP Certification #:100789 Pace Analytical Services Charlotte South Carolina Laboratory ID: 99006 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Laboratory ID: 99006 South Carolina Certification #: 99006001 South Carolina Drinking Water Cert. #: 99006003 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana DoH Drinking Water #: LA029 Virginia/VELAP Certification #: 460221 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 49 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92635127 44682-7940 Guilford College Lab ID Sample ID Matrix Date Collected Date Received 92635127001 DE-1 Solid 11/04/22 13:20 11/07/22 12:30 92635127002 DE-2 Solid 11/04/22 13:10 11/07/22 12:30 92635127003 DE-3 Solid 11/04/22 13:00 11/07/22 12:30 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 49 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92635127 44682-7940 Guilford College Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92635127001 DE-1 MADEP VPH 6 PANMGF EPA 8260D 70 PASI-CLMB SW-846 1 PASI-CKDF SM 2540G 1 PANCMK 92635127002 DE-2 MADEP VPH 6 PANMGF EPA 8260D 70 PASI-CLMB SW-846 1 PASI-CKDF SM 2540G 1 PANCMK 92635127003 DE-3 MADEP EPH 7 PASI-CAP2 MADEP VPH 6 PANMGF EPA 8270E 75 PASI-CBPJ EPA 8260D 70 PASI-CLMB SW-846 1 PASI-CKDF SM 2540G 1 PANCMK PAN = Pace National - Mt. Juliet PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 49 #=HO# SUMMARY OF DETECTION Pace Project No.: Project: 92635127 44682-7940 Guilford College Parameters AnalyzedResult Lab Sample ID Report Limit QualifiersUnitsMethod Client Sample ID 92635127001 DE-1 Aliphatic (C05-C08)9210 mg/kg 11/16/22 02:51557MADEP VPH Aliphatic (C09-C12)9390 mg/kg 11/16/22 02:51557MADEP VPH Aromatic (C09-C10),Unadjusted 8250 mg/kg 11/16/22 02:51557MADEP VPH Total VPH 26900 mg/kg 11/16/22 02:51557MADEP VPH Benzene 2.2 mg/kg 11/10/22 23:441.1EPA 8260D n-Butylbenzene 26.1 mg/kg 11/10/22 23:441.1EPA 8260D Ethylbenzene 135 mg/kg 11/10/22 23:441.1EPA 8260D Isopropylbenzene (Cumene)18.1 mg/kg 11/10/22 23:441.1EPA 8260D Naphthalene 91.5 mg/kg 11/10/22 23:441.1EPA 8260D n-Propylbenzene 78.0 mg/kg 11/10/22 23:441.1EPA 8260D Toluene 28.9 mg/kg 11/10/22 23:441.1EPA 8260D 1,2,4-Trimethylbenzene 540 mg/kg 11/10/22 23:441.1EPA 8260D 1,3,5-Trimethylbenzene 162 mg/kg 11/10/22 23:441.1EPA 8260D Xylene (Total)760 mg/kg 11/10/22 23:442.1EPA 8260D m&p-Xylene 588 mg/kg 11/10/22 23:442.1EPA 8260D o-Xylene 173 mg/kg 11/10/22 23:441.1EPA 8260D Percent Moisture 34.1 %11/08/22 16:25 N20.10SW-846 Total Solids 66.3 %11/11/22 07:47SM 2540G 92635127002 DE-2 Aliphatic (C05-C08)4.40J mg/kg 11/18/22 07:29 J10.1MADEP VPH Aliphatic (C09-C12)10.6 mg/kg 11/18/22 07:2910.1MADEP VPH Aromatic (C09-C10),Unadjusted 14.7 mg/kg 11/18/22 07:2910.1MADEP VPH Total VPH 29.8 mg/kg 11/18/22 07:2910.1MADEP VPH Benzene 0.20 mg/kg 11/10/22 03:180.012EPA 8260D Chlorobenzene 0.0083J mg/kg 11/10/22 03:180.012EPA 8260D Chloroform 0.036 mg/kg 11/10/22 03:180.012EPA 8260D Diisopropyl ether 0.015 mg/kg 11/10/22 03:180.012EPA 8260D Ethylbenzene 0.23 mg/kg 11/10/22 03:180.012EPA 8260D Isopropylbenzene (Cumene)0.034 mg/kg 11/10/22 03:180.012EPA 8260D Methylene Chloride 0.17 mg/kg 11/10/22 03:18 C90.048EPA 8260D Naphthalene 0.92 mg/kg 11/10/22 03:180.012EPA 8260D n-Propylbenzene 0.095 mg/kg 11/10/22 03:180.012EPA 8260D Toluene 0.091 mg/kg 11/10/22 03:180.012EPA 8260D 1,2,4-Trimethylbenzene 1.1 mg/kg 11/10/22 03:180.012EPA 8260D 1,3,5-Trimethylbenzene 0.33 mg/kg 11/10/22 03:180.012EPA 8260D Xylene (Total)1.4 mg/kg 11/10/22 03:180.024EPA 8260D m&p-Xylene 0.88 mg/kg 11/10/22 03:180.024EPA 8260D o-Xylene 0.49 mg/kg 11/10/22 03:180.012EPA 8260D Percent Moisture 33.8 %11/08/22 16:25 N20.10SW-846 Total Solids 66.1 %11/11/22 07:47SM 2540G 92635127003 DE-3 Aromatic (C09-C10),Unadjusted 4.22J mg/kg 11/18/22 08:01 J10.7MADEP VPH Total VPH 4.22J mg/kg 11/18/22 08:01 J10.7MADEP VPH Benzene 0.062 mg/kg 11/10/22 04:450.010EPA 8260D Chlorobenzene 0.0054J mg/kg 11/10/22 04:450.010EPA 8260D Chloroform 0.080 mg/kg 11/10/22 04:450.010EPA 8260D REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 49 #=HO# SUMMARY OF DETECTION Pace Project No.: Project: 92635127 44682-7940 Guilford College Parameters AnalyzedResult Lab Sample ID Report Limit QualifiersUnitsMethod Client Sample ID 92635127003 DE-3 Diisopropyl ether 0.011 mg/kg 11/10/22 04:450.010EPA 8260D Ethylbenzene 0.016 mg/kg 11/10/22 04:450.010EPA 8260D 2-Hexanone 0.026J mg/kg 11/10/22 04:450.10EPA 8260D Methylene Chloride 0.081 mg/kg 11/10/22 04:45 C90.041EPA 8260D Methyl-tert-butyl ether 0.034 mg/kg 11/10/22 04:450.010EPA 8260D Naphthalene 0.014 mg/kg 11/10/22 04:450.010EPA 8260D Toluene 0.038 mg/kg 11/10/22 04:450.010EPA 8260D 1,2,4-Trimethylbenzene 0.012 mg/kg 11/10/22 04:450.010EPA 8260D 1,3,5-Trimethylbenzene 0.012 mg/kg 11/10/22 04:450.010EPA 8260D Xylene (Total)0.047 mg/kg 11/10/22 04:450.020EPA 8260D m&p-Xylene 0.024 mg/kg 11/10/22 04:450.020EPA 8260D o-Xylene 0.022 mg/kg 11/10/22 04:450.010EPA 8260D Percent Moisture 33.6 %11/08/22 16:25 N20.10SW-846 Total Solids 65.8 %11/11/22 07:47SM 2540G REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 49 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92635127 44682-7940 Guilford College Sample:DE-1 Lab ID:92635127001 Collected:11/04/22 13:20 Received:11/07/22 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)9210 mg/kg 11/16/22 02:5111/04/22 13:2955718660.4 Aliphatic (C09-C12)9390 mg/kg 11/16/22 02:5111/04/22 13:2955718660.4 Aromatic (C09-C10),Unadjusted 8250 mg/kg 11/16/22 02:51 TPHC9C10A11/04/22 13:2955718660.4 Total VPH 26900 mg/kg 11/16/22 02:51 VPH11/04/22 13:2955718660.4 Surrogates 2,5-Dibromotoluene (FID)97.5 %11/16/22 02:51 615-59-8FID11/04/22 13:2970.0-130 60.4 2,5-Dibromotoluene (PID)79.4 %11/16/22 02:51 615-59-8PID11/04/22 13:2970.0-130 60.4 Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles Acetone ND mg/kg 11/10/22 23:44 67-64-111/10/22 17:3821.4 6.9 100 Benzene 2.2 mg/kg 11/10/22 23:44 71-43-211/10/22 17:381.1 0.43 100 Bromobenzene ND mg/kg 11/10/22 23:44 108-86-111/10/22 17:381.1 0.35 100 Bromochloromethane ND mg/kg 11/10/22 23:44 74-97-511/10/22 17:381.1 0.32 100 Bromodichloromethane ND mg/kg 11/10/22 23:44 75-27-411/10/22 17:381.1 0.41 100 Bromoform ND mg/kg 11/10/22 23:44 75-25-211/10/22 17:381.1 0.38 100 Bromomethane ND mg/kg 11/10/22 23:44 74-83-9 IK,v111/10/22 17:382.1 1.7 100 2-Butanone (MEK)ND mg/kg 11/10/22 23:44 78-93-311/10/22 17:3821.4 5.1 100 n-Butylbenzene 26.1 mg/kg 11/10/22 23:44 104-51-811/10/22 17:381.1 0.50 100 sec-Butylbenzene ND mg/kg 11/10/22 23:44 135-98-811/10/22 17:381.1 0.47 100 tert-Butylbenzene ND mg/kg 11/10/22 23:44 98-06-611/10/22 17:381.1 0.38 100 Carbon tetrachloride ND mg/kg 11/10/22 23:44 56-23-511/10/22 17:381.1 0.40 100 Chlorobenzene ND mg/kg 11/10/22 23:44 108-90-711/10/22 17:381.1 0.21 100 Chloroethane ND mg/kg 11/10/22 23:44 75-00-311/10/22 17:382.1 0.83 100 Chloroform ND mg/kg 11/10/22 23:44 67-66-311/10/22 17:381.1 0.65 100 Chloromethane ND mg/kg 11/10/22 23:44 74-87-311/10/22 17:382.1 0.90 100 2-Chlorotoluene ND mg/kg 11/10/22 23:44 95-49-811/10/22 17:381.1 0.38 100 4-Chlorotoluene ND mg/kg 11/10/22 23:44 106-43-411/10/22 17:381.1 0.19 100 1,2-Dibromo-3-chloropropane ND mg/kg 11/10/22 23:44 96-12-811/10/22 17:381.1 0.42 100 Dibromochloromethane ND mg/kg 11/10/22 23:44 124-48-111/10/22 17:381.1 0.60 100 1,2-Dibromoethane (EDB)ND mg/kg 11/10/22 23:44 106-93-411/10/22 17:381.1 0.47 100 Dibromomethane ND mg/kg 11/10/22 23:44 74-95-311/10/22 17:381.1 0.23 100 1,2-Dichlorobenzene ND mg/kg 11/10/22 23:44 95-50-111/10/22 17:381.1 0.39 100 1,3-Dichlorobenzene ND mg/kg 11/10/22 23:44 541-73-111/10/22 17:381.1 0.33 100 1,4-Dichlorobenzene ND mg/kg 11/10/22 23:44 106-46-711/10/22 17:381.1 0.28 100 Dichlorodifluoromethane ND mg/kg 11/10/22 23:44 75-71-811/10/22 17:382.1 0.46 100 1,1-Dichloroethane ND mg/kg 11/10/22 23:44 75-34-311/10/22 17:381.1 0.44 100 1,2-Dichloroethane ND mg/kg 11/10/22 23:44 107-06-211/10/22 17:381.1 0.71 100 1,1-Dichloroethene ND mg/kg 11/10/22 23:44 75-35-411/10/22 17:381.1 0.44 100 cis-1,2-Dichloroethene ND mg/kg 11/10/22 23:44 156-59-211/10/22 17:381.1 0.37 100 trans-1,2-Dichloroethene ND mg/kg 11/10/22 23:44 156-60-511/10/22 17:381.1 0.37 100 1,2-Dichloropropane ND mg/kg 11/10/22 23:44 78-87-511/10/22 17:381.1 0.32 100 1,3-Dichloropropane ND mg/kg 11/10/22 23:44 142-28-911/10/22 17:381.1 0.33 100 2,2-Dichloropropane ND mg/kg 11/10/22 23:44 594-20-711/10/22 17:381.1 0.35 100 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 49 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92635127 44682-7940 Guilford College Sample:DE-1 Lab ID:92635127001 Collected:11/04/22 13:20 Received:11/07/22 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles 1,1-Dichloropropene ND mg/kg 11/10/22 23:44 563-58-611/10/22 17:381.1 0.51 100 cis-1,3-Dichloropropene ND mg/kg 11/10/22 23:44 10061-01-511/10/22 17:381.1 0.29 100 trans-1,3-Dichloropropene ND mg/kg 11/10/22 23:44 10061-02-611/10/22 17:381.1 0.37 100 Diisopropyl ether ND mg/kg 11/10/22 23:44 108-20-311/10/22 17:381.1 0.29 100 Ethylbenzene 135 mg/kg 11/10/22 23:44 100-41-411/10/22 17:381.1 0.50 100 Hexachloro-1,3-butadiene ND mg/kg 11/10/22 23:44 87-68-311/10/22 17:382.1 1.8 100 2-Hexanone ND mg/kg 11/10/22 23:44 591-78-611/10/22 17:3810.7 1.0 100 Isopropylbenzene (Cumene)18.1 mg/kg 11/10/22 23:44 98-82-811/10/22 17:381.1 0.36 100 p-Isopropyltoluene ND mg/kg 11/10/22 23:44 99-87-611/10/22 17:381.1 0.53 100 Methylene Chloride ND mg/kg 11/10/22 23:44 75-09-211/10/22 17:384.3 2.9 100 4-Methyl-2-pentanone (MIBK)ND mg/kg 11/10/22 23:44 108-10-111/10/22 17:3810.7 1.0 100 Methyl-tert-butyl ether ND mg/kg 11/10/22 23:44 1634-04-411/10/22 17:381.1 0.40 100 Naphthalene 91.5 mg/kg 11/10/22 23:44 91-20-311/10/22 17:381.1 0.56 100 n-Propylbenzene 78.0 mg/kg 11/10/22 23:44 103-65-111/10/22 17:381.1 0.38 100 Styrene ND mg/kg 11/10/22 23:44 100-42-511/10/22 17:381.1 0.28 100 1,1,1,2-Tetrachloroethane ND mg/kg 11/10/22 23:44 630-20-611/10/22 17:381.1 0.41 100 1,1,2,2-Tetrachloroethane ND mg/kg 11/10/22 23:44 79-34-511/10/22 17:381.1 0.28 100 Tetrachloroethene ND mg/kg 11/10/22 23:44 127-18-411/10/22 17:381.1 0.34 100 Toluene 28.9 mg/kg 11/10/22 23:44 108-88-311/10/22 17:381.1 0.30 100 1,2,3-Trichlorobenzene ND mg/kg 11/10/22 23:44 87-61-611/10/22 17:381.1 0.86 100 1,2,4-Trichlorobenzene ND mg/kg 11/10/22 23:44 120-82-111/10/22 17:381.1 0.90 100 1,1,1-Trichloroethane ND mg/kg 11/10/22 23:44 71-55-611/10/22 17:381.1 0.56 100 1,1,2-Trichloroethane ND mg/kg 11/10/22 23:44 79-00-511/10/22 17:381.1 0.36 100 Trichloroethene ND mg/kg 11/10/22 23:44 79-01-611/10/22 17:381.1 0.28 100 Trichlorofluoromethane ND mg/kg 11/10/22 23:44 75-69-411/10/22 17:381.1 0.59 100 1,2,3-Trichloropropane ND mg/kg 11/10/22 23:44 96-18-411/10/22 17:381.1 0.54 100 1,2,4-Trimethylbenzene 540 mg/kg 11/10/22 23:44 95-63-611/10/22 17:381.1 0.29 100 1,3,5-Trimethylbenzene 162 mg/kg 11/10/22 23:44 108-67-811/10/22 17:381.1 0.36 100 Vinyl acetate ND mg/kg 11/10/22 23:44 108-05-411/10/22 17:3810.7 0.78 100 Vinyl chloride ND mg/kg 11/10/22 23:44 75-01-4 v111/10/22 17:382.1 0.54 100 Xylene (Total)760 mg/kg 11/10/22 23:44 1330-20-711/10/22 17:382.1 0.61 100 m&p-Xylene 588 mg/kg 11/10/22 23:44 179601-23-111/10/22 17:382.1 0.73 100 o-Xylene 173 mg/kg 11/10/22 23:44 95-47-611/10/22 17:381.1 0.47 100 Surrogates Toluene-d8 (S)100 %11/10/22 23:44 2037-26-511/10/22 17:3870-130 100 4-Bromofluorobenzene (S)98 %11/10/22 23:44 460-00-411/10/22 17:3870-130 100 1,2-Dichloroethane-d4 (S)95 %11/10/22 23:44 17060-07-011/10/22 17:3870-130 100 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 34.1 %11/08/22 16:25 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 49 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92635127 44682-7940 Guilford College Sample:DE-1 Lab ID:92635127001 Collected:11/04/22 13:20 Received:11/07/22 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: SM 2540G Preparation Method: SM 2540 G Pace National - Mt. Juliet Total Solids 2540 G-2011 Total Solids 66.3 %11/11/22 07:4711/11/22 07:381 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 49 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92635127 44682-7940 Guilford College Sample:DE-2 Lab ID:92635127002 Collected:11/04/22 13:10 Received:11/07/22 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)4.40J mg/kg 11/18/22 07:29 J11/04/22 13:2910.1 3.38 1 Aliphatic (C09-C12)10.6 mg/kg 11/18/22 07:2911/04/22 13:2910.1 3.38 1 Aromatic (C09-C10),Unadjusted 14.7 mg/kg 11/18/22 07:29 TPHC9C10A11/04/22 13:2910.1 3.38 1 Total VPH 29.8 mg/kg 11/18/22 07:29 VPH11/04/22 13:2910.1 3.38 1 Surrogates 2,5-Dibromotoluene (FID)83.6 %11/18/22 07:29 615-59-8FID11/04/22 13:2970.0-130 1 2,5-Dibromotoluene (PID)84.1 %11/18/22 07:29 615-59-8PID11/04/22 13:2970.0-130 1 Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles Acetone ND mg/kg 11/10/22 03:18 67-64-111/09/22 16:310.24 0.078 1 Benzene 0.20 mg/kg 11/10/22 03:18 71-43-211/09/22 16:310.012 0.0048 1 Bromobenzene ND mg/kg 11/10/22 03:18 108-86-111/09/22 16:310.012 0.0039 1 Bromochloromethane ND mg/kg 11/10/22 03:18 74-97-511/09/22 16:310.012 0.0036 1 Bromodichloromethane ND mg/kg 11/10/22 03:18 75-27-411/09/22 16:310.012 0.0047 1 Bromoform ND mg/kg 11/10/22 03:18 75-25-211/09/22 16:310.012 0.0043 1 Bromomethane ND mg/kg 11/10/22 03:18 74-83-911/09/22 16:310.024 0.019 1 2-Butanone (MEK)ND mg/kg 11/10/22 03:18 78-93-311/09/22 16:310.24 0.058 1 n-Butylbenzene ND mg/kg 11/10/22 03:18 104-51-811/09/22 16:310.012 0.0057 1 sec-Butylbenzene ND mg/kg 11/10/22 03:18 135-98-811/09/22 16:310.012 0.0053 1 tert-Butylbenzene ND mg/kg 11/10/22 03:18 98-06-611/09/22 16:310.012 0.0043 1 Carbon tetrachloride ND mg/kg 11/10/22 03:18 56-23-511/09/22 16:310.012 0.0045 1 Chlorobenzene 0.0083J mg/kg 11/10/22 03:18 108-90-711/09/22 16:310.012 0.0023 1 Chloroethane ND mg/kg 11/10/22 03:18 75-00-311/09/22 16:310.024 0.0093 1 Chloroform 0.036 mg/kg 11/10/22 03:18 67-66-311/09/22 16:310.012 0.0074 1 Chloromethane ND mg/kg 11/10/22 03:18 74-87-311/09/22 16:310.024 0.010 1 2-Chlorotoluene ND mg/kg 11/10/22 03:18 95-49-811/09/22 16:310.012 0.0043 1 4-Chlorotoluene ND mg/kg 11/10/22 03:18 106-43-411/09/22 16:310.012 0.0021 1 1,2-Dibromo-3-chloropropane ND mg/kg 11/10/22 03:18 96-12-8 IK11/09/22 16:310.012 0.0047 1 Dibromochloromethane ND mg/kg 11/10/22 03:18 124-48-111/09/22 16:310.012 0.0068 1 1,2-Dibromoethane (EDB)ND mg/kg 11/10/22 03:18 106-93-411/09/22 16:310.012 0.0053 1 Dibromomethane ND mg/kg 11/10/22 03:18 74-95-311/09/22 16:310.012 0.0026 1 1,2-Dichlorobenzene ND mg/kg 11/10/22 03:18 95-50-111/09/22 16:310.012 0.0044 1 1,3-Dichlorobenzene ND mg/kg 11/10/22 03:18 541-73-111/09/22 16:310.012 0.0038 1 1,4-Dichlorobenzene ND mg/kg 11/10/22 03:18 106-46-711/09/22 16:310.012 0.0031 1 Dichlorodifluoromethane ND mg/kg 11/10/22 03:18 75-71-811/09/22 16:310.024 0.0053 1 1,1-Dichloroethane ND mg/kg 11/10/22 03:18 75-34-311/09/22 16:310.012 0.0050 1 1,2-Dichloroethane ND mg/kg 11/10/22 03:18 107-06-211/09/22 16:310.012 0.0080 1 1,1-Dichloroethene ND mg/kg 11/10/22 03:18 75-35-411/09/22 16:310.012 0.0050 1 cis-1,2-Dichloroethene ND mg/kg 11/10/22 03:18 156-59-211/09/22 16:310.012 0.0041 1 trans-1,2-Dichloroethene ND mg/kg 11/10/22 03:18 156-60-511/09/22 16:310.012 0.0042 1 1,2-Dichloropropane ND mg/kg 11/10/22 03:18 78-87-511/09/22 16:310.012 0.0036 1 1,3-Dichloropropane ND mg/kg 11/10/22 03:18 142-28-911/09/22 16:310.012 0.0038 1 2,2-Dichloropropane ND mg/kg 11/10/22 03:18 594-20-711/09/22 16:310.012 0.0039 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 49 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92635127 44682-7940 Guilford College Sample:DE-2 Lab ID:92635127002 Collected:11/04/22 13:10 Received:11/07/22 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles 1,1-Dichloropropene ND mg/kg 11/10/22 03:18 563-58-611/09/22 16:310.012 0.0058 1 cis-1,3-Dichloropropene ND mg/kg 11/10/22 03:18 10061-01-511/09/22 16:310.012 0.0033 1 trans-1,3-Dichloropropene ND mg/kg 11/10/22 03:18 10061-02-611/09/22 16:310.012 0.0042 1 Diisopropyl ether 0.015 mg/kg 11/10/22 03:18 108-20-311/09/22 16:310.012 0.0033 1 Ethylbenzene 0.23 mg/kg 11/10/22 03:18 100-41-411/09/22 16:310.012 0.0056 1 Hexachloro-1,3-butadiene ND mg/kg 11/10/22 03:18 87-68-311/09/22 16:310.024 0.020 1 2-Hexanone ND mg/kg 11/10/22 03:18 591-78-611/09/22 16:310.12 0.012 1 Isopropylbenzene (Cumene)0.034 mg/kg 11/10/22 03:18 98-82-811/09/22 16:310.012 0.0041 1 p-Isopropyltoluene ND mg/kg 11/10/22 03:18 99-87-611/09/22 16:310.012 0.0060 1 Methylene Chloride 0.17 mg/kg 11/10/22 03:18 75-09-2 C911/09/22 16:310.048 0.033 1 4-Methyl-2-pentanone (MIBK)ND mg/kg 11/10/22 03:18 108-10-111/09/22 16:310.12 0.012 1 Methyl-tert-butyl ether ND mg/kg 11/10/22 03:18 1634-04-411/09/22 16:310.012 0.0045 1 Naphthalene 0.92 mg/kg 11/10/22 03:18 91-20-311/09/22 16:310.012 0.0064 1 n-Propylbenzene 0.095 mg/kg 11/10/22 03:18 103-65-111/09/22 16:310.012 0.0043 1 Styrene ND mg/kg 11/10/22 03:18 100-42-511/09/22 16:310.012 0.0032 1 1,1,1,2-Tetrachloroethane ND mg/kg 11/10/22 03:18 630-20-611/09/22 16:310.012 0.0047 1 1,1,2,2-Tetrachloroethane ND mg/kg 11/10/22 03:18 79-34-511/09/22 16:310.012 0.0032 1 Tetrachloroethene ND mg/kg 11/10/22 03:18 127-18-411/09/22 16:310.012 0.0038 1 Toluene 0.091 mg/kg 11/10/22 03:18 108-88-311/09/22 16:310.012 0.0034 1 1,2,3-Trichlorobenzene ND mg/kg 11/10/22 03:18 87-61-611/09/22 16:310.012 0.0098 1 1,2,4-Trichlorobenzene ND mg/kg 11/10/22 03:18 120-82-111/09/22 16:310.012 0.010 1 1,1,1-Trichloroethane ND mg/kg 11/10/22 03:18 71-55-611/09/22 16:310.012 0.0063 1 1,1,2-Trichloroethane ND mg/kg 11/10/22 03:18 79-00-511/09/22 16:310.012 0.0040 1 Trichloroethene ND mg/kg 11/10/22 03:18 79-01-611/09/22 16:310.012 0.0031 1 Trichlorofluoromethane ND mg/kg 11/10/22 03:18 75-69-411/09/22 16:310.012 0.0067 1 1,2,3-Trichloropropane ND mg/kg 11/10/22 03:18 96-18-411/09/22 16:310.012 0.0061 1 1,2,4-Trimethylbenzene 1.1 mg/kg 11/10/22 03:18 95-63-611/09/22 16:310.012 0.0033 1 1,3,5-Trimethylbenzene 0.33 mg/kg 11/10/22 03:18 108-67-811/09/22 16:310.012 0.0041 1 Vinyl acetate ND mg/kg 11/10/22 03:18 108-05-411/09/22 16:310.12 0.0088 1 Vinyl chloride ND mg/kg 11/10/22 03:18 75-01-411/09/22 16:310.024 0.0062 1 Xylene (Total)1.4 mg/kg 11/10/22 03:18 1330-20-711/09/22 16:310.024 0.0069 1 m&p-Xylene 0.88 mg/kg 11/10/22 03:18 179601-23-111/09/22 16:310.024 0.0083 1 o-Xylene 0.49 mg/kg 11/10/22 03:18 95-47-611/09/22 16:310.012 0.0054 1 Surrogates Toluene-d8 (S)101 %11/10/22 03:18 2037-26-511/09/22 16:3170-130 1 4-Bromofluorobenzene (S)104 %11/10/22 03:18 460-00-411/09/22 16:3170-130 1 1,2-Dichloroethane-d4 (S)104 %11/10/22 03:18 17060-07-011/09/22 16:3170-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 33.8 %11/08/22 16:25 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 49 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92635127 44682-7940 Guilford College Sample:DE-2 Lab ID:92635127002 Collected:11/04/22 13:10 Received:11/07/22 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: SM 2540G Preparation Method: SM 2540 G Pace National - Mt. Juliet Total Solids 2540 G-2011 Total Solids 66.1 %11/11/22 07:4711/11/22 07:381 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 49 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92635127 44682-7940 Guilford College Sample:DE-3 Lab ID:92635127003 Collected:11/04/22 13:00 Received:11/07/22 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP EPH Preparation Method: MADEP EPH Pace Analytical Services - Charlotte MADEP EPH NC Soil Aliphatic (C09-C18)ND mg/kg 11/11/22 15:25 N211/10/22 10:2314.9 14.9 1 Aliphatic (C19-C36)ND mg/kg 11/11/22 15:25 N211/10/22 10:2314.9 14.9 1 Aromatic (C11-C22)ND mg/kg 11/11/22 15:25 N211/10/22 10:2314.9 14.9 1 Surrogates 1-Chlorooctadecane (S)87 %11/11/22 15:25 3386-33-211/10/22 10:2340-140 1 o-Terphenyl (S)67 %11/11/22 15:25 84-15-111/10/22 10:2340-140 1 2-Fluorobiphenyl (S)116 %11/11/22 15:25 321-60-811/10/22 10:2340-140 1 2-Bromonaphthalene (S)121 %11/11/22 15:25 580-13-211/10/22 10:2340-140 1 Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)ND mg/kg 11/18/22 08:0111/04/22 13:2910.7 3.54 1.06 Aliphatic (C09-C12)ND mg/kg 11/18/22 08:0111/04/22 13:2910.7 3.54 1.06 Aromatic (C09-C10),Unadjusted 4.22J mg/kg 11/18/22 08:01 TPHC9C10A J11/04/22 13:2910.7 3.54 1.06 Total VPH 4.22J mg/kg 11/18/22 08:01 VPH J11/04/22 13:2910.7 3.54 1.06 Surrogates 2,5-Dibromotoluene (FID)82.4 %11/18/22 08:01 615-59-8FID11/04/22 13:2970.0-130 1.06 2,5-Dibromotoluene (PID)82.9 %11/18/22 08:01 615-59-8PID11/04/22 13:2970.0-130 1.06 Analytical Method: EPA 8270E Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8270E MSSV Microwave Acenaphthene ND ug/kg 11/16/22 11:21 83-32-911/15/22 16:025011761 Acenaphthylene ND ug/kg 11/16/22 11:21 208-96-811/15/22 16:025011761 Aniline ND ug/kg 11/16/22 11:21 62-53-311/15/22 16:025011961 Anthracene ND ug/kg 11/16/22 11:21 120-12-711/15/22 16:025011641 Benzo(a)anthracene ND ug/kg 11/16/22 11:21 56-55-311/15/22 16:025011671 Benzo(a)pyrene ND ug/kg 11/16/22 11:21 50-32-811/15/22 16:025011731 Benzo(b)fluoranthene ND ug/kg 11/16/22 11:21 205-99-211/15/22 16:025011671 Benzo(g,h,i)perylene ND ug/kg 11/16/22 11:21 191-24-211/15/22 16:025011941 Benzo(k)fluoranthene ND ug/kg 11/16/22 11:21 207-08-911/15/22 16:025011761 Benzoic Acid ND ug/kg 11/16/22 11:21 65-85-011/15/22 16:02250010801 Benzyl alcohol ND ug/kg 11/16/22 11:21 100-51-611/15/22 16:0210003791 4-Bromophenylphenyl ether ND ug/kg 11/16/22 11:21 101-55-311/15/22 16:025011931 Butylbenzylphthalate ND ug/kg 11/16/22 11:21 85-68-711/15/22 16:025012111 4-Chloro-3-methylphenol ND ug/kg 11/16/22 11:21 59-50-711/15/22 16:0210003521 4-Chloroaniline ND ug/kg 11/16/22 11:21 106-47-811/15/22 16:0210003931 bis(2-Chloroethoxy)methane ND ug/kg 11/16/22 11:21 111-91-111/15/22 16:025012081 bis(2-Chloroethyl) ether ND ug/kg 11/16/22 11:21 111-44-411/15/22 16:025011881 2-Chloronaphthalene ND ug/kg 11/16/22 11:21 91-58-711/15/22 16:025011991 2-Chlorophenol ND ug/kg 11/16/22 11:21 95-57-811/15/22 16:025011881 4-Chlorophenylphenyl ether ND ug/kg 11/16/22 11:21 7005-72-311/15/22 16:025011871 Chrysene ND ug/kg 11/16/22 11:21 218-01-911/15/22 16:025011821 Dibenz(a,h)anthracene ND ug/kg 11/16/22 11:21 53-70-311/15/22 16:025011931 Dibenzofuran ND ug/kg 11/16/22 11:21 132-64-911/15/22 16:025011811 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 49 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92635127 44682-7940 Guilford College Sample:DE-3 Lab ID:92635127003 Collected:11/04/22 13:00 Received:11/07/22 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8270E Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8270E MSSV Microwave 1,2-Dichlorobenzene ND ug/kg 11/16/22 11:21 95-50-111/15/22 16:025011811 1,3-Dichlorobenzene ND ug/kg 11/16/22 11:21 541-73-111/15/22 16:025011781 1,4-Dichlorobenzene ND ug/kg 11/16/22 11:21 106-46-711/15/22 16:025011911 3,3'-Dichlorobenzidine ND ug/kg 11/16/22 11:21 91-94-111/15/22 16:0210003381 2,4-Dichlorophenol ND ug/kg 11/16/22 11:21 120-83-211/15/22 16:025011961 Diethylphthalate ND ug/kg 11/16/22 11:21 84-66-211/15/22 16:025011841 2,4-Dimethylphenol ND ug/kg 11/16/22 11:21 105-67-911/15/22 16:025012081 Dimethylphthalate ND ug/kg 11/16/22 11:21 131-11-311/15/22 16:025011821 Di-n-butylphthalate ND ug/kg 11/16/22 11:21 84-74-211/15/22 16:025011681 4,6-Dinitro-2-methylphenol ND ug/kg 11/16/22 11:21 534-52-111/15/22 16:0210004671 2,4-Dinitrophenol ND ug/kg 11/16/22 11:21 51-28-511/15/22 16:02250015501 2,4-Dinitrotoluene ND ug/kg 11/16/22 11:21 121-14-211/15/22 16:025011931 2,6-Dinitrotoluene ND ug/kg 11/16/22 11:21 606-20-211/15/22 16:025011841 Di-n-octylphthalate ND ug/kg 11/16/22 11:21 117-84-011/15/22 16:025011971 bis(2-Ethylhexyl)phthalate ND ug/kg 11/16/22 11:21 117-81-711/15/22 16:025011941 Fluoranthene ND ug/kg 11/16/22 11:21 206-44-011/15/22 16:025011711 Fluorene ND ug/kg 11/16/22 11:21 86-73-711/15/22 16:025011761 Hexachloro-1,3-butadiene ND ug/kg 11/16/22 11:21 87-68-311/15/22 16:025012171 Hexachlorobenzene ND ug/kg 11/16/22 11:21 118-74-111/15/22 16:025011961 Hexachlorocyclopentadiene ND ug/kg 11/16/22 11:21 77-47-411/15/22 16:025012871 Hexachloroethane ND ug/kg 11/16/22 11:21 67-72-111/15/22 16:025011911 Indeno(1,2,3-cd)pyrene ND ug/kg 11/16/22 11:21 193-39-511/15/22 16:025011971 Isophorone ND ug/kg 11/16/22 11:21 78-59-111/15/22 16:025012231 1-Methylnaphthalene ND ug/kg 11/16/22 11:21 90-12-011/15/22 16:025011761 2-Methylnaphthalene ND ug/kg 11/16/22 11:21 91-57-611/15/22 16:025012001 2-Methylphenol(o-Cresol)ND ug/kg 11/16/22 11:21 95-48-711/15/22 16:025012051 3&4-Methylphenol(m&p Cresol)ND ug/kg 11/16/22 11:21 15831-10-411/15/22 16:025012021 Naphthalene ND ug/kg 11/16/22 11:21 91-20-311/15/22 16:025011701 2-Nitroaniline ND ug/kg 11/16/22 11:21 88-74-411/15/22 16:0225004101 3-Nitroaniline ND ug/kg 11/16/22 11:21 99-09-211/15/22 16:0225003931 4-Nitroaniline ND ug/kg 11/16/22 11:21 100-01-611/15/22 16:0210003811 Nitrobenzene ND ug/kg 11/16/22 11:21 98-95-311/15/22 16:025012321 2-Nitrophenol ND ug/kg 11/16/22 11:21 88-75-511/15/22 16:025012171 4-Nitrophenol ND ug/kg 11/16/22 11:21 100-02-711/15/22 16:0225009681 N-Nitrosodimethylamine ND ug/kg 11/16/22 11:21 62-75-911/15/22 16:025011681 N-Nitroso-di-n-propylamine ND ug/kg 11/16/22 11:21 621-64-711/15/22 16:025011881 N-Nitrosodiphenylamine ND ug/kg 11/16/22 11:21 86-30-611/15/22 16:025011781 2,2'-Oxybis(1-chloropropane)ND ug/kg 11/16/22 11:21 108-60-111/15/22 16:025012381 Pentachlorophenol ND ug/kg 11/16/22 11:21 87-86-511/15/22 16:0210004901 Phenanthrene ND ug/kg 11/16/22 11:21 85-01-811/15/22 16:025011641 Phenol ND ug/kg 11/16/22 11:21 108-95-211/15/22 16:025012231 Pyrene ND ug/kg 11/16/22 11:21 129-00-011/15/22 16:025012031 Pyridine ND ug/kg 11/16/22 11:21 110-86-111/15/22 16:025011581 1,2,4-Trichlorobenzene ND ug/kg 11/16/22 11:21 120-82-111/15/22 16:025011971 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 49 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92635127 44682-7940 Guilford College Sample:DE-3 Lab ID:92635127003 Collected:11/04/22 13:00 Received:11/07/22 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8270E Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8270E MSSV Microwave 2,4,5-Trichlorophenol ND ug/kg 11/16/22 11:21 95-95-411/15/22 16:025012291 2,4,6-Trichlorophenol ND ug/kg 11/16/22 11:21 88-06-211/15/22 16:025012061 Surrogates Nitrobenzene-d5 (S)59 %11/16/22 11:21 4165-60-011/15/22 16:0210-130 1 2-Fluorobiphenyl (S)58 %11/16/22 11:21 321-60-811/15/22 16:0210-130 1 Terphenyl-d14 (S)83 %11/16/22 11:21 1718-51-011/15/22 16:0210-130 1 Phenol-d6 (S)54 %11/16/22 11:21 13127-88-311/15/22 16:0210-130 1 2-Fluorophenol (S)57 %11/16/22 11:21 367-12-411/15/22 16:0210-130 1 2,4,6-Tribromophenol (S)89 %11/16/22 11:21 118-79-611/15/22 16:0210-131 1 Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles Acetone ND mg/kg 11/10/22 04:45 67-64-111/09/22 16:310.20 0.065 1 Benzene 0.062 mg/kg 11/10/22 04:45 71-43-211/09/22 16:310.010 0.0040 1 Bromobenzene ND mg/kg 11/10/22 04:45 108-86-111/09/22 16:310.010 0.0033 1 Bromochloromethane ND mg/kg 11/10/22 04:45 74-97-511/09/22 16:310.010 0.0030 1 Bromodichloromethane ND mg/kg 11/10/22 04:45 75-27-411/09/22 16:310.010 0.0039 1 Bromoform ND mg/kg 11/10/22 04:45 75-25-211/09/22 16:310.010 0.0036 1 Bromomethane ND mg/kg 11/10/22 04:45 74-83-911/09/22 16:310.020 0.016 1 2-Butanone (MEK)ND mg/kg 11/10/22 04:45 78-93-311/09/22 16:310.20 0.049 1 n-Butylbenzene ND mg/kg 11/10/22 04:45 104-51-811/09/22 16:310.010 0.0048 1 sec-Butylbenzene ND mg/kg 11/10/22 04:45 135-98-811/09/22 16:310.010 0.0045 1 tert-Butylbenzene ND mg/kg 11/10/22 04:45 98-06-611/09/22 16:310.010 0.0036 1 Carbon tetrachloride ND mg/kg 11/10/22 04:45 56-23-511/09/22 16:310.010 0.0038 1 Chlorobenzene 0.0054J mg/kg 11/10/22 04:45 108-90-711/09/22 16:310.010 0.0019 1 Chloroethane ND mg/kg 11/10/22 04:45 75-00-311/09/22 16:310.020 0.0078 1 Chloroform 0.080 mg/kg 11/10/22 04:45 67-66-311/09/22 16:310.010 0.0062 1 Chloromethane ND mg/kg 11/10/22 04:45 74-87-311/09/22 16:310.020 0.0085 1 2-Chlorotoluene ND mg/kg 11/10/22 04:45 95-49-811/09/22 16:310.010 0.0036 1 4-Chlorotoluene ND mg/kg 11/10/22 04:45 106-43-411/09/22 16:310.010 0.0018 1 1,2-Dibromo-3-chloropropane ND mg/kg 11/10/22 04:45 96-12-8 IK11/09/22 16:310.010 0.0039 1 Dibromochloromethane ND mg/kg 11/10/22 04:45 124-48-111/09/22 16:310.010 0.0057 1 1,2-Dibromoethane (EDB)ND mg/kg 11/10/22 04:45 106-93-411/09/22 16:310.010 0.0045 1 Dibromomethane ND mg/kg 11/10/22 04:45 74-95-311/09/22 16:310.010 0.0022 1 1,2-Dichlorobenzene ND mg/kg 11/10/22 04:45 95-50-111/09/22 16:310.010 0.0037 1 1,3-Dichlorobenzene ND mg/kg 11/10/22 04:45 541-73-111/09/22 16:310.010 0.0031 1 1,4-Dichlorobenzene ND mg/kg 11/10/22 04:45 106-46-711/09/22 16:310.010 0.0026 1 Dichlorodifluoromethane ND mg/kg 11/10/22 04:45 75-71-811/09/22 16:310.020 0.0044 1 1,1-Dichloroethane ND mg/kg 11/10/22 04:45 75-34-311/09/22 16:310.010 0.0042 1 1,2-Dichloroethane ND mg/kg 11/10/22 04:45 107-06-211/09/22 16:310.010 0.0067 1 1,1-Dichloroethene ND mg/kg 11/10/22 04:45 75-35-411/09/22 16:310.010 0.0042 1 cis-1,2-Dichloroethene ND mg/kg 11/10/22 04:45 156-59-211/09/22 16:310.010 0.0035 1 trans-1,2-Dichloroethene ND mg/kg 11/10/22 04:45 156-60-511/09/22 16:310.010 0.0036 1 1,2-Dichloropropane ND mg/kg 11/10/22 04:45 78-87-511/09/22 16:310.010 0.0030 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 15 of 49 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92635127 44682-7940 Guilford College Sample:DE-3 Lab ID:92635127003 Collected:11/04/22 13:00 Received:11/07/22 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles 1,3-Dichloropropane ND mg/kg 11/10/22 04:45 142-28-911/09/22 16:310.010 0.0032 1 2,2-Dichloropropane ND mg/kg 11/10/22 04:45 594-20-711/09/22 16:310.010 0.0033 1 1,1-Dichloropropene ND mg/kg 11/10/22 04:45 563-58-611/09/22 16:310.010 0.0049 1 cis-1,3-Dichloropropene ND mg/kg 11/10/22 04:45 10061-01-511/09/22 16:310.010 0.0028 1 trans-1,3-Dichloropropene ND mg/kg 11/10/22 04:45 10061-02-611/09/22 16:310.010 0.0035 1 Diisopropyl ether 0.011 mg/kg 11/10/22 04:45 108-20-311/09/22 16:310.010 0.0027 1 Ethylbenzene 0.016 mg/kg 11/10/22 04:45 100-41-411/09/22 16:310.010 0.0047 1 Hexachloro-1,3-butadiene ND mg/kg 11/10/22 04:45 87-68-311/09/22 16:310.020 0.017 1 2-Hexanone 0.026J mg/kg 11/10/22 04:45 591-78-611/09/22 16:310.10 0.0098 1 Isopropylbenzene (Cumene)ND mg/kg 11/10/22 04:45 98-82-811/09/22 16:310.010 0.0034 1 p-Isopropyltoluene ND mg/kg 11/10/22 04:45 99-87-611/09/22 16:310.010 0.0050 1 Methylene Chloride 0.081 mg/kg 11/10/22 04:45 75-09-2 C911/09/22 16:310.041 0.028 1 4-Methyl-2-pentanone (MIBK)ND mg/kg 11/10/22 04:45 108-10-111/09/22 16:310.10 0.0098 1 Methyl-tert-butyl ether 0.034 mg/kg 11/10/22 04:45 1634-04-411/09/22 16:310.010 0.0038 1 Naphthalene 0.014 mg/kg 11/10/22 04:45 91-20-311/09/22 16:310.010 0.0053 1 n-Propylbenzene ND mg/kg 11/10/22 04:45 103-65-111/09/22 16:310.010 0.0036 1 Styrene ND mg/kg 11/10/22 04:45 100-42-511/09/22 16:310.010 0.0027 1 1,1,1,2-Tetrachloroethane ND mg/kg 11/10/22 04:45 630-20-611/09/22 16:310.010 0.0039 1 1,1,2,2-Tetrachloroethane ND mg/kg 11/10/22 04:45 79-34-511/09/22 16:310.010 0.0027 1 Tetrachloroethene ND mg/kg 11/10/22 04:45 127-18-411/09/22 16:310.010 0.0032 1 Toluene 0.038 mg/kg 11/10/22 04:45 108-88-311/09/22 16:310.010 0.0029 1 1,2,3-Trichlorobenzene ND mg/kg 11/10/22 04:45 87-61-611/09/22 16:310.010 0.0082 1 1,2,4-Trichlorobenzene ND mg/kg 11/10/22 04:45 120-82-111/09/22 16:310.010 0.0085 1 1,1,1-Trichloroethane ND mg/kg 11/10/22 04:45 71-55-611/09/22 16:310.010 0.0053 1 1,1,2-Trichloroethane ND mg/kg 11/10/22 04:45 79-00-511/09/22 16:310.010 0.0034 1 Trichloroethene ND mg/kg 11/10/22 04:45 79-01-611/09/22 16:310.010 0.0026 1 Trichlorofluoromethane ND mg/kg 11/10/22 04:45 75-69-411/09/22 16:310.010 0.0056 1 1,2,3-Trichloropropane ND mg/kg 11/10/22 04:45 96-18-411/09/22 16:310.010 0.0051 1 1,2,4-Trimethylbenzene 0.012 mg/kg 11/10/22 04:45 95-63-611/09/22 16:310.010 0.0028 1 1,3,5-Trimethylbenzene 0.012 mg/kg 11/10/22 04:45 108-67-811/09/22 16:310.010 0.0034 1 Vinyl acetate ND mg/kg 11/10/22 04:45 108-05-411/09/22 16:310.10 0.0074 1 Vinyl chloride ND mg/kg 11/10/22 04:45 75-01-411/09/22 16:310.020 0.0052 1 Xylene (Total)0.047 mg/kg 11/10/22 04:45 1330-20-711/09/22 16:310.020 0.0058 1 m&p-Xylene 0.024 mg/kg 11/10/22 04:45 179601-23-111/09/22 16:310.020 0.0069 1 o-Xylene 0.022 mg/kg 11/10/22 04:45 95-47-611/09/22 16:310.010 0.0045 1 Surrogates Toluene-d8 (S)101 %11/10/22 04:45 2037-26-511/09/22 16:3170-130 1 4-Bromofluorobenzene (S)99 %11/10/22 04:45 460-00-411/09/22 16:3170-130 1 1,2-Dichloroethane-d4 (S)103 %11/10/22 04:45 17060-07-011/09/22 16:3170-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 33.6 %11/08/22 16:25 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 16 of 49 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92635127 44682-7940 Guilford College Sample:DE-3 Lab ID:92635127003 Collected:11/04/22 13:00 Received:11/07/22 12:30 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: SM 2540G Preparation Method: SM 2540 G Pace National - Mt. Juliet Total Solids 2540 G-2011 Total Solids 65.8 %11/11/22 07:4711/11/22 07:381 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 17 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 1958808 KS LRH/MADEPV/MTDEQ VPH/VPH MADEP VPH MADEPV Laboratory:Pace National - Mt. Juliet Associated Lab Samples:92635127001 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3861488-3 Associated Lab Samples:92635127001 Matrix:Solid AnalyzedMDL Aliphatic (C05-C08)mg/kg ND 5.00 11/15/22 13:161.67 Aliphatic (C09-C12)mg/kg ND 5.00 11/15/22 13:161.67 Aromatic (C09-C10),Unadjusted mg/kg ND 5.00 11/15/22 13:161.67 Total VPH mg/kg ND 5.00 11/15/22 13:161.67 2,5-Dibromotoluene (FID)%82.9 70.0-130 11/15/22 13:16 2,5-Dibromotoluene (PID)%82.5 70.0-130 11/15/22 13:16 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3861488-1LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result R3861488-2 Aliphatic (C05-C08)mg/kg 53.360.0 88.8 70.0-13097.858.7 9.64 25 Aliphatic (C09-C12)mg/kg 67.270.0 96.0 70.0-13094.366.0 1.80 25 Aromatic (C09-C10),Unadjusted mg/kg 12.610.0 126 70.0-13011811.8 6.56 25 Total VPH mg/kg 133140 95.0 70.0-13097.9137 2.96 25 2,5-Dibromotoluene (FID)%84.1 70.0-13095.1 2,5-Dibromotoluene (PID)%84.8 70.0-13096.0 Parameter Units MS Result % Rec Limits Qual% RecConc. R3861488-4MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result L1554414-06 R3861488-5 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Aliphatic (C05-C08)mg/kg 283 85.4 70.0-13090.3 2.64 25283272514528 Aliphatic (C09-C12)mg/kg 331 129 70.0-130130 0.384 2533176811901200 Aromatic (C09- C10),Unadjusted mg/kg E,P647.1 162 70.0-130153 0.837 2547.1474 551 546 Total VPH mg/kg 660 114 70.0-130114 0.00 25660151022602260 2,5-Dibromotoluene (FID)%116 70.0-130113 2,5-Dibromotoluene (PID)%84.4 70.0-13084.1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 18 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 1958808 MADEPV MADEP VPH MADEPV Laboratory:Pace National - Mt. Juliet Associated Lab Samples:92635127001 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3861488-3 Associated Lab Samples:92635127001 Matrix:Solid AnalyzedMDL Aliphatic (C05-C08)mg/kg ND 5.00 11/15/22 13:161.67 Aliphatic (C09-C12)mg/kg ND 5.00 11/15/22 13:161.67 Aromatic (C09-C10),Unadjusted mg/kg ND 5.00 11/15/22 13:161.67 Total VPH mg/kg ND 5.00 11/15/22 13:161.67 2,5-Dibromotoluene (FID)%82.9 70.0-130 11/15/22 13:16 2,5-Dibromotoluene (PID)%82.5 70.0-130 11/15/22 13:16 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3861488-1LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result R3861488-2 Aliphatic (C05-C08)mg/kg 53.360.0 88.8 70.0-13097.858.7 9.64 25 Aliphatic (C09-C12)mg/kg 67.270.0 96.0 70.0-13094.366.0 1.80 25 Aromatic (C09-C10),Unadjusted mg/kg 12.610.0 126 70.0-13011811.8 6.56 25 Total VPH mg/kg 133140 95.0 70.0-13097.9137 2.96 25 2,5-Dibromotoluene (FID)%84.1 70.0-13095.1 2,5-Dibromotoluene (PID)%84.8 70.0-13096.0 Parameter Units MS Result % Rec Limits Qual% RecConc. R3861488-4MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result L1554414-06 R3861488-5 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Aliphatic (C05-C08)mg/kg 283 85.4 70.0-13090.3 2.64 25283272514528 Aliphatic (C09-C12)mg/kg 331 129 70.0-130130 0.384 2533176811901200 Aromatic (C09- C10),Unadjusted mg/kg E,P647.1 162 70.0-130153 0.837 2547.1474 551 546 Total VPH mg/kg 660 114 70.0-130114 0.00 25660151022602260 2,5-Dibromotoluene (FID)%116 70.0-130113 2,5-Dibromotoluene (PID)%84.4 70.0-13084.1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 19 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 1960505 KS LRH/MADEPV/MTDEQ VPH/VPH MADEP VPH MADEPV Laboratory:Pace National - Mt. Juliet Associated Lab Samples:92635127002, 92635127003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3862627-3 Associated Lab Samples:92635127002, 92635127003 Matrix:Solid AnalyzedMDL Aliphatic (C05-C08)mg/kg ND 5.00 11/17/22 23:191.67 Aliphatic (C09-C12)mg/kg ND 5.00 11/17/22 23:191.67 Aromatic (C09-C10),Unadjusted mg/kg ND 5.00 11/17/22 23:191.67 Total VPH mg/kg ND 5.00 11/17/22 23:191.67 2,5-Dibromotoluene (FID)%79 70.0-130 11/17/22 23:19 2,5-Dibromotoluene (PID)%81.3 70.0-130 11/17/22 23:19 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3862627-1LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result R3862627-2 Aliphatic (C05-C08)mg/kg 49.360.0 82.2 70.0-13084.550.7 2.80 25 Aliphatic (C09-C12)mg/kg 61.070.0 87.1 70.0-13087.060.9 0.164 25 Aromatic (C09-C10),Unadjusted mg/kg 11.510.0 115 70.0-13011411.4 0.873 25 Total VPH mg/kg 122140 87.1 70.0-13087.9123 0.816 25 2,5-Dibromotoluene (FID)%90.7 70.0-13092.1 2,5-Dibromotoluene (PID)%93.5 70.0-13094.8 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 20 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 736012 EPA 5035A/5030B EPA 8260D 8260D 5035A 5030B Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92635127002, 92635127003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3830657 Associated Lab Samples:92635127002, 92635127003 Matrix:Solid AnalyzedMDL 1,1,1,2-Tetrachloroethane mg/kg ND 0.0050 11/09/22 21:160.0019 1,1,1-Trichloroethane mg/kg ND 0.0050 11/09/22 21:160.0026 1,1,2,2-Tetrachloroethane mg/kg ND 0.0050 11/09/22 21:160.0013 1,1,2-Trichloroethane mg/kg ND 0.0050 11/09/22 21:160.0017 1,1-Dichloroethane mg/kg ND 0.0050 11/09/22 21:160.0021 1,1-Dichloroethene mg/kg ND 0.0050 11/09/22 21:160.0021 1,1-Dichloropropene mg/kg ND 0.0050 11/09/22 21:160.0024 1,2,3-Trichlorobenzene mg/kg ND 0.0050 11/09/22 21:160.0040 1,2,3-Trichloropropane mg/kg ND 0.0050 11/09/22 21:160.0025 1,2,4-Trichlorobenzene mg/kg ND 0.0050 11/09/22 21:160.0042 1,2,4-Trimethylbenzene mg/kg ND 0.0050 11/09/22 21:160.0014 1,2-Dibromo-3-chloropropane mg/kg ND 0.0050 IK11/09/22 21:160.0019 1,2-Dibromoethane (EDB)mg/kg ND 0.0050 11/09/22 21:160.0022 1,2-Dichlorobenzene mg/kg ND 0.0050 11/09/22 21:160.0018 1,2-Dichloroethane mg/kg ND 0.0050 11/09/22 21:160.0033 1,2-Dichloropropane mg/kg ND 0.0050 11/09/22 21:160.0015 1,3,5-Trimethylbenzene mg/kg ND 0.0050 11/09/22 21:160.0017 1,3-Dichlorobenzene mg/kg ND 0.0050 11/09/22 21:160.0016 1,3-Dichloropropane mg/kg ND 0.0050 11/09/22 21:160.0016 1,4-Dichlorobenzene mg/kg ND 0.0050 11/09/22 21:160.0013 2,2-Dichloropropane mg/kg ND 0.0050 11/09/22 21:160.0016 2-Butanone (MEK)mg/kg ND 0.10 11/09/22 21:160.024 2-Chlorotoluene mg/kg ND 0.0050 11/09/22 21:160.0018 2-Hexanone mg/kg ND 0.050 11/09/22 21:160.0048 4-Chlorotoluene mg/kg ND 0.0050 11/09/22 21:160.00088 4-Methyl-2-pentanone (MIBK)mg/kg ND 0.050 11/09/22 21:160.0048 Acetone mg/kg ND 0.10 11/09/22 21:160.032 Benzene mg/kg ND 0.0050 11/09/22 21:160.0020 Bromobenzene mg/kg ND 0.0050 11/09/22 21:160.0016 Bromochloromethane mg/kg ND 0.0050 11/09/22 21:160.0015 Bromodichloromethane mg/kg ND 0.0050 11/09/22 21:160.0019 Bromoform mg/kg ND 0.0050 11/09/22 21:160.0018 Bromomethane mg/kg ND 0.010 11/09/22 21:160.0079 Carbon tetrachloride mg/kg ND 0.0050 11/09/22 21:160.0019 Chlorobenzene mg/kg ND 0.0050 11/09/22 21:160.00096 Chloroethane mg/kg ND 0.010 11/09/22 21:160.0039 Chloroform mg/kg ND 0.0050 11/09/22 21:160.0030 Chloromethane mg/kg ND 0.010 11/09/22 21:160.0042 cis-1,2-Dichloroethene mg/kg ND 0.0050 11/09/22 21:160.0017 cis-1,3-Dichloropropene mg/kg ND 0.0050 11/09/22 21:160.0014 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 21 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3830657 Associated Lab Samples:92635127002, 92635127003 Matrix:Solid AnalyzedMDL Dibromochloromethane mg/kg ND 0.0050 11/09/22 21:160.0028 Dibromomethane mg/kg ND 0.0050 11/09/22 21:160.0011 Dichlorodifluoromethane mg/kg ND 0.010 11/09/22 21:160.0022 Diisopropyl ether mg/kg ND 0.0050 11/09/22 21:160.0014 Ethylbenzene mg/kg ND 0.0050 11/09/22 21:160.0023 Hexachloro-1,3-butadiene mg/kg ND 0.010 11/09/22 21:160.0082 Isopropylbenzene (Cumene)mg/kg ND 0.0050 11/09/22 21:160.0017 m&p-Xylene mg/kg ND 0.010 11/09/22 21:160.0034 Methyl-tert-butyl ether mg/kg ND 0.0050 11/09/22 21:160.0019 Methylene Chloride mg/kg ND 0.020 11/09/22 21:160.014 n-Butylbenzene mg/kg ND 0.0050 11/09/22 21:160.0024 n-Propylbenzene mg/kg ND 0.0050 11/09/22 21:160.0018 Naphthalene mg/kg ND 0.0050 11/09/22 21:160.0026 o-Xylene mg/kg ND 0.0050 11/09/22 21:160.0022 p-Isopropyltoluene mg/kg ND 0.0050 11/09/22 21:160.0025 sec-Butylbenzene mg/kg ND 0.0050 11/09/22 21:160.0022 Styrene mg/kg ND 0.0050 11/09/22 21:160.0013 tert-Butylbenzene mg/kg ND 0.0050 11/09/22 21:160.0018 Tetrachloroethene mg/kg ND 0.0050 11/09/22 21:160.0016 Toluene mg/kg ND 0.0050 11/09/22 21:160.0014 trans-1,2-Dichloroethene mg/kg ND 0.0050 11/09/22 21:160.0018 trans-1,3-Dichloropropene mg/kg ND 0.0050 11/09/22 21:160.0017 Trichloroethene mg/kg ND 0.0050 11/09/22 21:160.0013 Trichlorofluoromethane mg/kg ND 0.0050 11/09/22 21:160.0028 Vinyl acetate mg/kg ND 0.050 11/09/22 21:160.0036 Vinyl chloride mg/kg ND 0.010 11/09/22 21:160.0025 Xylene (Total)mg/kg ND 0.010 11/09/22 21:160.0028 1,2-Dichloroethane-d4 (S)%99 70-130 11/09/22 21:16 4-Bromofluorobenzene (S)%97 70-130 11/09/22 21:16 Toluene-d8 (S)%99 70-130 11/09/22 21:16 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3830658LABORATORY CONTROL SAMPLE: LCSSpike 1,1,1,2-Tetrachloroethane mg/kg 1.21.2 96 70-130 1,1,1-Trichloroethane mg/kg 1.21.2 94 70-130 1,1,2,2-Tetrachloroethane mg/kg 1.21.2 97 70-130 1,1,2-Trichloroethane mg/kg 1.21.2 100 70-130 1,1-Dichloroethane mg/kg 1.21.2 96 70-130 1,1-Dichloroethene mg/kg 1.31.2 102 70-130 1,1-Dichloropropene mg/kg 1.21.2 98 70-130 1,2,3-Trichlorobenzene mg/kg 1.21.2 92 70-130 1,2,3-Trichloropropane mg/kg 1.21.2 99 70-130 1,2,4-Trichlorobenzene mg/kg 1.21.2 98 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 22 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3830658LABORATORY CONTROL SAMPLE: LCSSpike 1,2,4-Trimethylbenzene mg/kg 1.21.2 98 70-130 1,2-Dibromo-3-chloropropane mg/kg 1.1 IK1.2 92 67-130 1,2-Dibromoethane (EDB)mg/kg 1.21.2 95 70-130 1,2-Dichlorobenzene mg/kg 1.21.2 96 70-130 1,2-Dichloroethane mg/kg 1.21.2 96 70-130 1,2-Dichloropropane mg/kg 1.21.2 95 70-130 1,3,5-Trimethylbenzene mg/kg 1.21.2 100 70-130 1,3-Dichlorobenzene mg/kg 1.21.2 94 70-130 1,3-Dichloropropane mg/kg 1.21.2 94 70-130 1,4-Dichlorobenzene mg/kg 1.21.2 95 70-130 2,2-Dichloropropane mg/kg 1.31.2 103 67-130 2-Butanone (MEK)mg/kg 2.52.5 98 66-130 2-Chlorotoluene mg/kg 1.21.2 96 70-130 2-Hexanone mg/kg 2.62.5 106 70-130 4-Chlorotoluene mg/kg 1.21.2 95 70-130 4-Methyl-2-pentanone (MIBK)mg/kg 2.62.5 106 70-130 Acetone mg/kg 2.32.5 91 67-130 Benzene mg/kg 1.21.2 93 70-130 Bromobenzene mg/kg 1.21.2 97 70-130 Bromochloromethane mg/kg 1.21.2 95 70-130 Bromodichloromethane mg/kg 1.31.2 100 70-130 Bromoform mg/kg 1.31.2 103 70-130 Bromomethane mg/kg 1.31.2 105 53-175 Carbon tetrachloride mg/kg 1.31.2 103 70-130 Chlorobenzene mg/kg 1.21.2 94 70-130 Chloroethane mg/kg 1.31.2 101 70-135 Chloroform mg/kg 1.11.2 89 70-130 Chloromethane mg/kg 1.31.2 100 64-130 cis-1,2-Dichloroethene mg/kg 1.21.2 95 70-130 cis-1,3-Dichloropropene mg/kg 1.31.2 101 70-130 Dibromochloromethane mg/kg 1.21.2 98 70-130 Dibromomethane mg/kg 1.31.2 100 70-130 Dichlorodifluoromethane mg/kg 1.11.2 92 63-145 Diisopropyl ether mg/kg 1.21.2 92 68-130 Ethylbenzene mg/kg 1.11.2 90 70-130 Hexachloro-1,3-butadiene mg/kg 1.31.2 102 70-130 Isopropylbenzene (Cumene)mg/kg 1.21.2 95 70-130 m&p-Xylene mg/kg 2.42.5 95 70-130 Methyl-tert-butyl ether mg/kg 1.21.2 95 70-130 Methylene Chloride mg/kg 1.11.2 92 67-130 n-Butylbenzene mg/kg 1.21.2 95 70-130 n-Propylbenzene mg/kg 1.21.2 97 70-130 Naphthalene mg/kg 1.31.2 104 70-130 o-Xylene mg/kg 1.21.2 96 70-130 p-Isopropyltoluene mg/kg 1.21.2 100 70-130 sec-Butylbenzene mg/kg 1.21.2 98 70-130 Styrene mg/kg 1.21.2 99 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 23 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3830658LABORATORY CONTROL SAMPLE: LCSSpike tert-Butylbenzene mg/kg 1.21.2 93 64-130 Tetrachloroethene mg/kg 1.21.2 93 70-130 Toluene mg/kg 1.21.2 95 70-130 trans-1,2-Dichloroethene mg/kg 1.21.2 98 70-130 trans-1,3-Dichloropropene mg/kg 1.31.2 105 70-130 Trichloroethene mg/kg 1.21.2 97 70-130 Trichlorofluoromethane mg/kg 1.11.2 89 70-130 Vinyl acetate mg/kg 2.72.5 108 70-134 Vinyl chloride mg/kg 1.31.2 106 68-130 Xylene (Total)mg/kg 3.63.8 95 70-130 1,2-Dichloroethane-d4 (S)%95 70-130 4-Bromofluorobenzene (S)%101 70-130 Toluene-d8 (S)%101 70-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3830659MATRIX SPIKE SAMPLE: MSSpike Result 92635266001 1,1,1,2-Tetrachloroethane mg/kg 0.650.83 78 58-140ND 1,1,1-Trichloroethane mg/kg 0.740.83 89 58-144ND 1,1,2,2-Tetrachloroethane mg/kg 0.670.83 80 52-139ND 1,1,2-Trichloroethane mg/kg 0.700.83 83 56-140ND 1,1-Dichloroethane mg/kg 0.750.83 90 58-145ND 1,1-Dichloroethene mg/kg 0.830.83 100 57-158ND 1,1-Dichloropropene mg/kg 0.740.83 88 58-151ND 1,2,3-Trichlorobenzene mg/kg 0.550.83 66 48-149ND 1,2,3-Trichloropropane mg/kg 0.650.83 78 54-132ND 1,2,4-Trichlorobenzene mg/kg 0.610.83 73 51-151ND 1,2,4-Trimethylbenzene mg/kg 0.870.83 85 38-1700.16 1,2-Dibromo-3-chloropropane mg/kg 0.46 IK0.83 56 44-134ND 1,2-Dibromoethane (EDB)mg/kg 0.660.83 79 60-138ND 1,2-Dichlorobenzene mg/kg 0.660.83 79 59-147ND 1,2-Dichloroethane mg/kg 0.700.83 84 57-139ND 1,2-Dichloropropane mg/kg 0.680.83 82 62-145ND 1,3,5-Trimethylbenzene mg/kg 0.800.83 82 47-1590.11 1,3-Dichlorobenzene mg/kg 0.610.83 73 58-144ND 1,3-Dichloropropane mg/kg 0.670.83 81 60-142ND 1,4-Dichlorobenzene mg/kg 0.640.83 77 57-143ND 2,2-Dichloropropane mg/kg 0.700.83 84 37-144ND 2-Butanone (MEK)mg/kg 1.41.6 83 28-146ND 2-Chlorotoluene mg/kg 0.660.83 79 55-158ND 2-Hexanone mg/kg 1.21.6 75 44-141ND 4-Chlorotoluene mg/kg 0.630.83 75 55-146ND 4-Methyl-2-pentanone (MIBK)mg/kg 1.31.6 78 50-138ND Acetone mg/kg 1.01.6 62 20-136ND Benzene mg/kg 0.800.83 83 60-1450.10 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 24 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3830659MATRIX SPIKE SAMPLE: MSSpike Result 92635266001 Bromobenzene mg/kg 0.670.83 79 59-145ND Bromochloromethane mg/kg 0.720.83 86 57-143ND Bromodichloromethane mg/kg 0.630.83 75 53-133ND Bromoform mg/kg 0.550.83 65 48-133ND Bromomethane mg/kg 0.420.83 50 10-167ND Carbon tetrachloride mg/kg 0.620.83 74 57-147ND Chlorobenzene mg/kg 0.700.83 82 61-144ND Chloroethane mg/kg 0.270.83 33 10-153ND Chloroform mg/kg 0.710.83 84 58-141ND Chloromethane mg/kg 0.850.83 102 54-165ND cis-1,2-Dichloroethene mg/kg 0.750.83 90 59-144ND cis-1,3-Dichloropropene mg/kg 0.640.83 77 56-137ND Dibromochloromethane mg/kg 0.590.83 71 53-139ND Dibromomethane mg/kg 0.670.83 80 60-136ND Dichlorodifluoromethane mg/kg 1.00.83 124 49-177ND Diisopropyl ether mg/kg 0.700.83 83 53-136ND Ethylbenzene mg/kg 0.920.83 80 53-1500.25 Hexachloro-1,3-butadiene mg/kg 0.690.83 82 42-186ND Isopropylbenzene (Cumene)mg/kg 0.750.83 83 62-1540.047 m&p-Xylene mg/kg 1.51.6 82 49-1560.11 Methyl-tert-butyl ether mg/kg 0.700.83 84 54-133ND Methylene Chloride mg/kg 0.820.83 87 50-1530.089 n-Butylbenzene mg/kg 0.770.83 82 44-1740.079 n-Propylbenzene mg/kg 0.850.83 80 52-1570.18 Naphthalene mg/kg 0.820.83 71 37-1500.23 o-Xylene mg/kg 0.730.83 83 54-1500.032 p-Isopropyltoluene mg/kg 0.690.83 82 50-164ND sec-Butylbenzene mg/kg 0.690.83 82 58-161ND Styrene mg/kg 0.680.83 82 60-148ND tert-Butylbenzene mg/kg 0.640.83 77 44-151ND Tetrachloroethene mg/kg 0.600.83 72 53-151ND Toluene mg/kg 0.700.83 81 52-1480.017 trans-1,2-Dichloroethene mg/kg 0.750.83 89 60-148ND trans-1,3-Dichloropropene mg/kg 0.660.83 79 55-133ND Trichloroethene mg/kg 0.670.83 80 60-148ND Trichlorofluoromethane mg/kg 0.500.83 59 10-154ND Vinyl acetate mg/kg 1.41.6 81 50-149ND Vinyl chloride mg/kg 0.890.83 106 57-157ND Xylene (Total)mg/kg 2.22.5 83 52-1530.14 1,2-Dichloroethane-d4 (S)%102 70-130 4-Bromofluorobenzene (S)%104 70-130 Toluene-d8 (S)%100 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 25 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92635270001 3830660SAMPLE DUPLICATE: 1,1,1,2-Tetrachloroethane mg/kg ND 30ND 1,1,1-Trichloroethane mg/kg ND 30ND 1,1,2,2-Tetrachloroethane mg/kg ND 30ND 1,1,2-Trichloroethane mg/kg ND 30ND 1,1-Dichloroethane mg/kg ND 30ND 1,1-Dichloroethene mg/kg ND 30ND 1,1-Dichloropropene mg/kg ND 30ND 1,2,3-Trichlorobenzene mg/kg ND 30ND 1,2,3-Trichloropropane mg/kg ND 30ND 1,2,4-Trichlorobenzene mg/kg ND 30ND 1,2,4-Trimethylbenzene mg/kg 0.0039J 30ND 1,2-Dibromo-3-chloropropane mg/kg ND 30ND 1,2-Dibromoethane (EDB)mg/kg ND 30ND 1,2-Dichlorobenzene mg/kg ND 30ND 1,2-Dichloroethane mg/kg ND 30ND 1,2-Dichloropropane mg/kg ND 30ND 1,3,5-Trimethylbenzene mg/kg ND 30ND 1,3-Dichlorobenzene mg/kg ND 30ND 1,3-Dichloropropane mg/kg ND 30ND 1,4-Dichlorobenzene mg/kg ND 30ND 2,2-Dichloropropane mg/kg ND 30ND 2-Butanone (MEK)mg/kg ND 30ND 2-Chlorotoluene mg/kg ND 30ND 2-Hexanone mg/kg ND 30ND 4-Chlorotoluene mg/kg ND 30ND 4-Methyl-2-pentanone (MIBK)mg/kg ND 30ND Acetone mg/kg ND 30ND Benzene mg/kg ND 30ND Bromobenzene mg/kg ND 30ND Bromochloromethane mg/kg ND 30ND Bromodichloromethane mg/kg ND 30ND Bromoform mg/kg ND 30ND Bromomethane mg/kg ND IK,v130ND Carbon tetrachloride mg/kg ND 30ND Chlorobenzene mg/kg 0.0040J 30ND Chloroethane mg/kg ND 30ND Chloroform mg/kg ND 30ND Chloromethane mg/kg ND 30ND cis-1,2-Dichloroethene mg/kg ND 30ND cis-1,3-Dichloropropene mg/kg ND 30ND Dibromochloromethane mg/kg ND 30ND Dibromomethane mg/kg ND 30ND Dichlorodifluoromethane mg/kg ND 30ND Diisopropyl ether mg/kg ND 30ND Ethylbenzene mg/kg 0.0043J 30ND Hexachloro-1,3-butadiene mg/kg ND 30ND Isopropylbenzene (Cumene)mg/kg ND 30ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 26 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92635270001 3830660SAMPLE DUPLICATE: m&p-Xylene mg/kg 0.0099J 30ND Methyl-tert-butyl ether mg/kg ND 30ND Methylene Chloride mg/kg 0.085 C9,D658300.15 n-Butylbenzene mg/kg ND 30ND n-Propylbenzene mg/kg ND 30ND Naphthalene mg/kg ND 30ND o-Xylene mg/kg 0.0078 16 300.0091 p-Isopropyltoluene mg/kg ND 30ND sec-Butylbenzene mg/kg ND 30ND Styrene mg/kg ND 30ND tert-Butylbenzene mg/kg ND 30ND Tetrachloroethene mg/kg ND 30ND Toluene mg/kg 0.0058J 30ND trans-1,2-Dichloroethene mg/kg ND 30ND trans-1,3-Dichloropropene mg/kg ND 30ND Trichloroethene mg/kg ND 30ND Trichlorofluoromethane mg/kg ND 30ND Vinyl acetate mg/kg ND 30ND Vinyl chloride mg/kg ND v130ND Xylene (Total)mg/kg 0.0078J 30ND 1,2-Dichloroethane-d4 (S)%102100 4-Bromofluorobenzene (S)%99101 Toluene-d8 (S)%101101 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 27 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 736340 EPA 5035A/5030B EPA 8260D 8260D 5035A 5030B Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92635127001 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3832388 Associated Lab Samples:92635127001 Matrix:Solid AnalyzedMDL 1,1,1,2-Tetrachloroethane mg/kg ND 0.0050 11/10/22 19:230.0019 1,1,1-Trichloroethane mg/kg ND 0.0050 11/10/22 19:230.0026 1,1,2,2-Tetrachloroethane mg/kg ND 0.0050 11/10/22 19:230.0013 1,1,2-Trichloroethane mg/kg ND 0.0050 11/10/22 19:230.0017 1,1-Dichloroethane mg/kg ND 0.0050 11/10/22 19:230.0021 1,1-Dichloroethene mg/kg ND 0.0050 11/10/22 19:230.0021 1,1-Dichloropropene mg/kg ND 0.0050 11/10/22 19:230.0024 1,2,3-Trichlorobenzene mg/kg ND 0.0050 11/10/22 19:230.0040 1,2,3-Trichloropropane mg/kg ND 0.0050 11/10/22 19:230.0025 1,2,4-Trichlorobenzene mg/kg ND 0.0050 11/10/22 19:230.0042 1,2,4-Trimethylbenzene mg/kg ND 0.0050 11/10/22 19:230.0014 1,2-Dibromo-3-chloropropane mg/kg ND 0.0050 11/10/22 19:230.0019 1,2-Dibromoethane (EDB)mg/kg ND 0.0050 11/10/22 19:230.0022 1,2-Dichlorobenzene mg/kg ND 0.0050 11/10/22 19:230.0018 1,2-Dichloroethane mg/kg ND 0.0050 11/10/22 19:230.0033 1,2-Dichloropropane mg/kg ND 0.0050 11/10/22 19:230.0015 1,3,5-Trimethylbenzene mg/kg ND 0.0050 11/10/22 19:230.0017 1,3-Dichlorobenzene mg/kg ND 0.0050 11/10/22 19:230.0016 1,3-Dichloropropane mg/kg ND 0.0050 11/10/22 19:230.0016 1,4-Dichlorobenzene mg/kg ND 0.0050 11/10/22 19:230.0013 2,2-Dichloropropane mg/kg ND 0.0050 11/10/22 19:230.0016 2-Butanone (MEK)mg/kg ND 0.10 11/10/22 19:230.024 2-Chlorotoluene mg/kg ND 0.0050 11/10/22 19:230.0018 2-Hexanone mg/kg ND 0.050 11/10/22 19:230.0048 4-Chlorotoluene mg/kg ND 0.0050 11/10/22 19:230.00088 4-Methyl-2-pentanone (MIBK)mg/kg ND 0.050 11/10/22 19:230.0048 Acetone mg/kg ND 0.10 11/10/22 19:230.032 Benzene mg/kg ND 0.0050 11/10/22 19:230.0020 Bromobenzene mg/kg ND 0.0050 11/10/22 19:230.0016 Bromochloromethane mg/kg ND 0.0050 11/10/22 19:230.0015 Bromodichloromethane mg/kg ND 0.0050 11/10/22 19:230.0019 Bromoform mg/kg ND 0.0050 11/10/22 19:230.0018 Bromomethane mg/kg ND 0.010 IK,v111/10/22 19:230.0079 Carbon tetrachloride mg/kg ND 0.0050 11/10/22 19:230.0019 Chlorobenzene mg/kg ND 0.0050 11/10/22 19:230.00096 Chloroethane mg/kg ND 0.010 11/10/22 19:230.0039 Chloroform mg/kg ND 0.0050 11/10/22 19:230.0030 Chloromethane mg/kg ND 0.010 11/10/22 19:230.0042 cis-1,2-Dichloroethene mg/kg ND 0.0050 11/10/22 19:230.0017 cis-1,3-Dichloropropene mg/kg ND 0.0050 11/10/22 19:230.0014 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 28 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3832388 Associated Lab Samples:92635127001 Matrix:Solid AnalyzedMDL Dibromochloromethane mg/kg ND 0.0050 11/10/22 19:230.0028 Dibromomethane mg/kg ND 0.0050 11/10/22 19:230.0011 Dichlorodifluoromethane mg/kg ND 0.010 11/10/22 19:230.0022 Diisopropyl ether mg/kg ND 0.0050 11/10/22 19:230.0014 Ethylbenzene mg/kg ND 0.0050 11/10/22 19:230.0023 Hexachloro-1,3-butadiene mg/kg ND 0.010 11/10/22 19:230.0082 Isopropylbenzene (Cumene)mg/kg ND 0.0050 11/10/22 19:230.0017 m&p-Xylene mg/kg ND 0.010 11/10/22 19:230.0034 Methyl-tert-butyl ether mg/kg ND 0.0050 11/10/22 19:230.0019 Methylene Chloride mg/kg ND 0.020 11/10/22 19:230.014 n-Butylbenzene mg/kg ND 0.0050 11/10/22 19:230.0024 n-Propylbenzene mg/kg ND 0.0050 11/10/22 19:230.0018 Naphthalene mg/kg ND 0.0050 11/10/22 19:230.0026 o-Xylene mg/kg ND 0.0050 11/10/22 19:230.0022 p-Isopropyltoluene mg/kg ND 0.0050 11/10/22 19:230.0025 sec-Butylbenzene mg/kg ND 0.0050 11/10/22 19:230.0022 Styrene mg/kg ND 0.0050 11/10/22 19:230.0013 tert-Butylbenzene mg/kg ND 0.0050 11/10/22 19:230.0018 Tetrachloroethene mg/kg ND 0.0050 11/10/22 19:230.0016 Toluene mg/kg ND 0.0050 11/10/22 19:230.0014 trans-1,2-Dichloroethene mg/kg ND 0.0050 11/10/22 19:230.0018 trans-1,3-Dichloropropene mg/kg ND 0.0050 11/10/22 19:230.0017 Trichloroethene mg/kg ND 0.0050 11/10/22 19:230.0013 Trichlorofluoromethane mg/kg ND 0.0050 11/10/22 19:230.0028 Vinyl acetate mg/kg ND 0.050 11/10/22 19:230.0036 Vinyl chloride mg/kg ND 0.010 v111/10/22 19:230.0025 Xylene (Total)mg/kg ND 0.010 11/10/22 19:230.0028 1,2-Dichloroethane-d4 (S)%98 70-130 11/10/22 19:23 4-Bromofluorobenzene (S)%94 70-130 11/10/22 19:23 Toluene-d8 (S)%100 70-130 11/10/22 19:23 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3832389LABORATORY CONTROL SAMPLE: LCSSpike 1,1,1,2-Tetrachloroethane mg/kg 1.31.2 105 70-130 1,1,1-Trichloroethane mg/kg 1.31.2 101 70-130 1,1,2,2-Tetrachloroethane mg/kg 1.11.2 89 70-130 1,1,2-Trichloroethane mg/kg 1.21.2 98 70-130 1,1-Dichloroethane mg/kg 1.21.2 99 70-130 1,1-Dichloroethene mg/kg 1.31.2 104 70-130 1,1-Dichloropropene mg/kg 1.31.2 107 70-130 1,2,3-Trichlorobenzene mg/kg 1.21.2 96 70-130 1,2,3-Trichloropropane mg/kg 1.11.2 89 70-130 1,2,4-Trichlorobenzene mg/kg 1.21.2 95 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 29 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3832389LABORATORY CONTROL SAMPLE: LCSSpike 1,2,4-Trimethylbenzene mg/kg 1.21.2 99 70-130 1,2-Dibromo-3-chloropropane mg/kg 1.11.2 87 67-130 1,2-Dibromoethane (EDB)mg/kg 1.21.2 98 70-130 1,2-Dichlorobenzene mg/kg 1.21.2 95 70-130 1,2-Dichloroethane mg/kg 1.21.2 98 70-130 1,2-Dichloropropane mg/kg 1.31.2 105 70-130 1,3,5-Trimethylbenzene mg/kg 1.21.2 96 70-130 1,3-Dichlorobenzene mg/kg 1.21.2 99 70-130 1,3-Dichloropropane mg/kg 1.21.2 94 70-130 1,4-Dichlorobenzene mg/kg 1.31.2 101 70-130 2,2-Dichloropropane mg/kg 1.21.2 95 67-130 2-Butanone (MEK)mg/kg 2.32.5 93 66-130 2-Chlorotoluene mg/kg 1.21.2 93 70-130 2-Hexanone mg/kg 2.22.5 89 70-130 4-Chlorotoluene mg/kg 1.21.2 96 70-130 4-Methyl-2-pentanone (MIBK)mg/kg 2.32.5 93 70-130 Acetone mg/kg 2.12.5 83 67-130 Benzene mg/kg 1.31.2 101 70-130 Bromobenzene mg/kg 1.21.2 97 70-130 Bromochloromethane mg/kg 1.31.2 106 70-130 Bromodichloromethane mg/kg 1.21.2 100 70-130 Bromoform mg/kg 1.31.2 106 70-130 Bromomethane mg/kg 1.8 IK,v11.2 141 53-175 Carbon tetrachloride mg/kg 1.41.2 109 70-130 Chlorobenzene mg/kg 1.31.2 103 70-130 Chloroethane mg/kg 1.41.2 115 70-135 Chloroform mg/kg 1.21.2 95 70-130 Chloromethane mg/kg 1.41.2 109 64-130 cis-1,2-Dichloroethene mg/kg 1.21.2 98 70-130 cis-1,3-Dichloropropene mg/kg 1.31.2 102 70-130 Dibromochloromethane mg/kg 1.31.2 100 70-130 Dibromomethane mg/kg 1.41.2 109 70-130 Dichlorodifluoromethane mg/kg 1.51.2 119 63-145 Diisopropyl ether mg/kg 1.11.2 91 68-130 Ethylbenzene mg/kg 1.21.2 94 70-130 Hexachloro-1,3-butadiene mg/kg 1.21.2 98 70-130 Isopropylbenzene (Cumene)mg/kg 1.21.2 100 70-130 m&p-Xylene mg/kg 2.52.5 101 70-130 Methyl-tert-butyl ether mg/kg 1.21.2 94 70-130 Methylene Chloride mg/kg 1.11.2 90 67-130 n-Butylbenzene mg/kg 1.21.2 98 70-130 n-Propylbenzene mg/kg 1.21.2 98 70-130 Naphthalene mg/kg 1.11.2 90 70-130 o-Xylene mg/kg 1.31.2 103 70-130 p-Isopropyltoluene mg/kg 1.21.2 97 70-130 sec-Butylbenzene mg/kg 1.21.2 95 70-130 Styrene mg/kg 1.31.2 103 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 30 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3832389LABORATORY CONTROL SAMPLE: LCSSpike tert-Butylbenzene mg/kg 1.21.2 98 64-130 Tetrachloroethene mg/kg 1.41.2 114 70-130 Toluene mg/kg 1.31.2 102 70-130 trans-1,2-Dichloroethene mg/kg 1.31.2 103 70-130 trans-1,3-Dichloropropene mg/kg 1.31.2 101 70-130 Trichloroethene mg/kg 1.41.2 113 70-130 Trichlorofluoromethane mg/kg 1.41.2 110 70-130 Vinyl acetate mg/kg 2.72.5 109 70-134 Vinyl chloride mg/kg 1.5 v11.2 122 68-130 Xylene (Total)mg/kg 3.83.8 102 70-130 1,2-Dichloroethane-d4 (S)%88 70-130 4-Bromofluorobenzene (S)%98 70-130 Toluene-d8 (S)%99 70-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3832390MATRIX SPIKE SAMPLE: MSSpike Result 92635823001 1,1,1,2-Tetrachloroethane mg/kg 0.96 M10.68 142 58-140ND 1,1,1-Trichloroethane mg/kg 0.950.68 140 58-144ND 1,1,2,2-Tetrachloroethane mg/kg 0.810.68 119 52-139ND 1,1,2-Trichloroethane mg/kg 0.900.68 132 56-140ND 1,1-Dichloroethane mg/kg 0.940.68 138 58-145ND 1,1-Dichloroethene mg/kg 0.990.68 146 57-158ND 1,1-Dichloropropene mg/kg 0.970.68 144 58-151ND 1,2,3-Trichlorobenzene mg/kg 0.24 M10.68 36 48-149ND 1,2,3-Trichloropropane mg/kg 0.770.68 114 54-132ND 1,2,4-Trichlorobenzene mg/kg 0.460.68 68 51-151ND 1,2,4-Trimethylbenzene mg/kg 0.890.68 131 38-1703.7J ug/kg 1,2-Dibromo-3-chloropropane mg/kg 0.480.68 70 44-134ND 1,2-Dibromoethane (EDB)mg/kg 0.870.68 129 60-138ND 1,2-Dichlorobenzene mg/kg 0.860.68 128 59-147ND 1,2-Dichloroethane mg/kg 0.910.68 135 57-139ND 1,2-Dichloropropane mg/kg 0.960.68 142 62-145ND 1,3,5-Trimethylbenzene mg/kg 0.860.68 128 47-159ND 1,3-Dichlorobenzene mg/kg 0.880.68 130 58-144ND 1,3-Dichloropropane mg/kg 0.870.68 128 60-142ND 1,4-Dichlorobenzene mg/kg 0.850.68 125 57-143ND 2,2-Dichloropropane mg/kg 0.830.68 122 37-144ND 2-Butanone (MEK)mg/kg 1.41.4 104 28-146ND 2-Chlorotoluene mg/kg 0.830.68 122 55-158ND 2-Hexanone mg/kg 1.41.4 101 44-141ND 4-Chlorotoluene mg/kg 0.830.68 122 55-146ND 4-Methyl-2-pentanone (MIBK)mg/kg 1.61.4 115 50-138ND Acetone mg/kg 1.21.4 88 20-136ND Benzene mg/kg 0.920.68 136 60-145ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 31 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3832390MATRIX SPIKE SAMPLE: MSSpike Result 92635823001 Bromobenzene mg/kg 0.870.68 128 59-145ND Bromochloromethane mg/kg 0.97 M10.68 144 57-143ND Bromodichloromethane mg/kg 0.900.68 133 53-133ND Bromoform mg/kg 0.93 M10.68 138 48-133ND Bromomethane mg/kg 0.63 IK,v10.68 93 10-167ND Carbon tetrachloride mg/kg 0.810.68 119 57-147ND Chlorobenzene mg/kg 0.920.68 136 61-144ND Chloroethane mg/kg 0.140.68 20 10-153ND Chloroform mg/kg 0.900.68 132 58-141ND Chloromethane mg/kg 1.10.68 156 54-165ND cis-1,2-Dichloroethene mg/kg 0.910.68 134 59-144ND cis-1,3-Dichloropropene mg/kg 0.920.68 136 56-137ND Dibromochloromethane mg/kg 0.880.68 131 53-139ND Dibromomethane mg/kg 0.97 M10.68 143 60-136ND Dichlorodifluoromethane mg/kg 1.3 M10.68 195 49-177ND Diisopropyl ether mg/kg 0.840.68 124 53-136ND Ethylbenzene mg/kg 0.840.68 124 53-150ND Hexachloro-1,3-butadiene mg/kg 1.10.68 169 42-186ND Isopropylbenzene (Cumene)mg/kg 0.910.68 134 62-154ND m&p-Xylene mg/kg 1.81.4 131 49-156ND Methyl-tert-butyl ether mg/kg 0.850.68 126 54-133ND Methylene Chloride mg/kg 0.990.68 131 50-153103 ug/kg n-Butylbenzene mg/kg 0.960.68 141 44-174ND n-Propylbenzene mg/kg 0.870.68 128 52-157ND Naphthalene mg/kg 0.16 M10.68 23 37-150ND o-Xylene mg/kg 0.920.68 136 54-150ND p-Isopropyltoluene mg/kg 0.920.68 136 50-164ND sec-Butylbenzene mg/kg 0.940.68 138 58-161ND Styrene mg/kg 0.910.68 135 60-148ND tert-Butylbenzene mg/kg 0.930.68 138 44-151ND Tetrachloroethene mg/kg 0.920.68 136 53-151ND Toluene mg/kg 0.930.68 138 52-148ND trans-1,2-Dichloroethene mg/kg 0.930.68 137 60-148ND trans-1,3-Dichloropropene mg/kg 0.91 M10.68 135 55-133ND Trichloroethene mg/kg 1.00.68 148 60-148ND Trichlorofluoromethane mg/kg 0.130.68 19 10-154ND Vinyl acetate mg/kg 1.81.4 132 50-149ND Vinyl chloride mg/kg 1.2 M1,v10.68 172 57-157ND Xylene (Total)mg/kg 2.72 133 52-153ND 1,2-Dichloroethane-d4 (S)%97 70-130 4-Bromofluorobenzene (S)%100 70-130 Toluene-d8 (S)%100 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 32 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92635830001 3832391SAMPLE DUPLICATE: 1,1,1,2-Tetrachloroethane mg/kg ND 30ND 1,1,1-Trichloroethane mg/kg ND 30ND 1,1,2,2-Tetrachloroethane mg/kg ND 30ND 1,1,2-Trichloroethane mg/kg ND 30ND 1,1-Dichloroethane mg/kg ND 30ND 1,1-Dichloroethene mg/kg ND 30ND 1,1-Dichloropropene mg/kg ND 30ND 1,2,3-Trichlorobenzene mg/kg ND 30ND 1,2,3-Trichloropropane mg/kg ND 30ND 1,2,4-Trichlorobenzene mg/kg ND 30ND 1,2,4-Trimethylbenzene mg/kg ND 30ND 1,2-Dibromo-3-chloropropane mg/kg ND 30ND 1,2-Dibromoethane (EDB)mg/kg ND 30ND 1,2-Dichlorobenzene mg/kg ND 30ND 1,2-Dichloroethane mg/kg ND 30ND 1,2-Dichloropropane mg/kg ND 30ND 1,3,5-Trimethylbenzene mg/kg ND 30ND 1,3-Dichlorobenzene mg/kg ND 30ND 1,3-Dichloropropane mg/kg ND 30ND 1,4-Dichlorobenzene mg/kg ND 30ND 2,2-Dichloropropane mg/kg ND 30ND 2-Butanone (MEK)mg/kg ND 30ND 2-Chlorotoluene mg/kg ND 30ND 2-Hexanone mg/kg ND 30ND 4-Chlorotoluene mg/kg ND 30ND 4-Methyl-2-pentanone (MIBK)mg/kg ND 30ND Acetone mg/kg ND 30ND Benzene mg/kg ND 30ND Bromobenzene mg/kg ND 30ND Bromochloromethane mg/kg ND 30ND Bromodichloromethane mg/kg ND 30ND Bromoform mg/kg ND 30ND Bromomethane mg/kg ND IK,v130ND Carbon tetrachloride mg/kg ND 30ND Chlorobenzene mg/kg ND 30ND Chloroethane mg/kg ND 30ND Chloroform mg/kg ND 30ND Chloromethane mg/kg ND 30ND cis-1,2-Dichloroethene mg/kg ND 30ND cis-1,3-Dichloropropene mg/kg ND 30ND Dibromochloromethane mg/kg ND 30ND Dibromomethane mg/kg ND 30ND Dichlorodifluoromethane mg/kg ND 30ND Diisopropyl ether mg/kg ND 30ND Ethylbenzene mg/kg ND 30ND Hexachloro-1,3-butadiene mg/kg ND 30ND Isopropylbenzene (Cumene)mg/kg ND 30ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 33 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92635830001 3832391SAMPLE DUPLICATE: m&p-Xylene mg/kg ND 30ND Methyl-tert-butyl ether mg/kg ND 30ND Methylene Chloride mg/kg 0.12 C9,D64030173 ug/kg n-Butylbenzene mg/kg ND 30ND n-Propylbenzene mg/kg ND 30ND Naphthalene mg/kg ND 30ND o-Xylene mg/kg ND 30ND p-Isopropyltoluene mg/kg ND 30ND sec-Butylbenzene mg/kg ND 30ND Styrene mg/kg ND 30ND tert-Butylbenzene mg/kg ND 30ND Tetrachloroethene mg/kg ND 30ND Toluene mg/kg ND 30ND trans-1,2-Dichloroethene mg/kg ND 30ND trans-1,3-Dichloropropene mg/kg ND 30ND Trichloroethene mg/kg ND 30ND Trichlorofluoromethane mg/kg ND 30ND Vinyl acetate mg/kg ND 30ND Vinyl chloride mg/kg ND v130ND Xylene (Total)mg/kg ND 30ND 1,2-Dichloroethane-d4 (S)%102104 4-Bromofluorobenzene (S)%9999 Toluene-d8 (S)%101101 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 34 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 737176 EPA 3546 EPA 8270E 8270E Solid MSSV Microwave Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92635127003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3836458 Associated Lab Samples:92635127003 Matrix:Solid AnalyzedMDL 1,2,4-Trichlorobenzene ug/kg ND 334 11/16/22 07:42132 1,2-Dichlorobenzene ug/kg ND 334 11/16/22 07:42121 1,3-Dichlorobenzene ug/kg ND 334 11/16/22 07:42119 1,4-Dichlorobenzene ug/kg ND 334 11/16/22 07:42128 1-Methylnaphthalene ug/kg ND 334 11/16/22 07:42118 2,2'-Oxybis(1-chloropropane)ug/kg ND 334 11/16/22 07:42159 2,4,5-Trichlorophenol ug/kg ND 334 11/16/22 07:42153 2,4,6-Trichlorophenol ug/kg ND 334 11/16/22 07:42138 2,4-Dichlorophenol ug/kg ND 334 11/16/22 07:42131 2,4-Dimethylphenol ug/kg ND 334 11/16/22 07:42139 2,4-Dinitrophenol ug/kg ND 1670 11/16/22 07:421030 2,4-Dinitrotoluene ug/kg ND 334 11/16/22 07:42129 2,6-Dinitrotoluene ug/kg ND 334 11/16/22 07:42123 2-Chloronaphthalene ug/kg ND 334 11/16/22 07:42133 2-Chlorophenol ug/kg ND 334 11/16/22 07:42126 2-Methylnaphthalene ug/kg ND 334 11/16/22 07:42134 2-Methylphenol(o-Cresol)ug/kg ND 334 11/16/22 07:42137 2-Nitroaniline ug/kg ND 1670 11/16/22 07:42274 2-Nitrophenol ug/kg ND 334 11/16/22 07:42145 3&4-Methylphenol(m&p Cresol)ug/kg ND 334 11/16/22 07:42135 3,3'-Dichlorobenzidine ug/kg ND 669 11/16/22 07:42226 3-Nitroaniline ug/kg ND 1670 11/16/22 07:42262 4,6-Dinitro-2-methylphenol ug/kg ND 669 11/16/22 07:42312 4-Bromophenylphenyl ether ug/kg ND 334 11/16/22 07:42129 4-Chloro-3-methylphenol ug/kg ND 669 11/16/22 07:42235 4-Chloroaniline ug/kg ND 669 11/16/22 07:42262 4-Chlorophenylphenyl ether ug/kg ND 334 11/16/22 07:42125 4-Nitroaniline ug/kg ND 669 11/16/22 07:42254 4-Nitrophenol ug/kg ND 1670 11/16/22 07:42647 Acenaphthene ug/kg ND 334 11/16/22 07:42118 Acenaphthylene ug/kg ND 334 11/16/22 07:42118 Aniline ug/kg ND 334 11/16/22 07:42131 Anthracene ug/kg ND 334 11/16/22 07:42109 Benzo(a)anthracene ug/kg ND 334 11/16/22 07:42111 Benzo(a)pyrene ug/kg ND 334 11/16/22 07:42116 Benzo(b)fluoranthene ug/kg ND 334 11/16/22 07:42111 Benzo(g,h,i)perylene ug/kg ND 334 11/16/22 07:42130 Benzo(k)fluoranthene ug/kg ND 334 11/16/22 07:42118 Benzoic Acid ug/kg ND 1670 11/16/22 07:42719 Benzyl alcohol ug/kg ND 669 11/16/22 07:42253 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 35 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3836458 Associated Lab Samples:92635127003 Matrix:Solid AnalyzedMDL bis(2-Chloroethoxy)methane ug/kg ND 334 11/16/22 07:42139 bis(2-Chloroethyl) ether ug/kg ND 334 11/16/22 07:42126 bis(2-Ethylhexyl)phthalate ug/kg ND 334 11/16/22 07:42130 Butylbenzylphthalate ug/kg ND 334 11/16/22 07:42141 Chrysene ug/kg ND 334 11/16/22 07:42122 Di-n-butylphthalate ug/kg ND 334 11/16/22 07:42112 Di-n-octylphthalate ug/kg ND 334 11/16/22 07:42132 Dibenz(a,h)anthracene ug/kg ND 334 11/16/22 07:42129 Dibenzofuran ug/kg ND 334 11/16/22 07:42121 Diethylphthalate ug/kg ND 334 11/16/22 07:42123 Dimethylphthalate ug/kg ND 334 11/16/22 07:42122 Fluoranthene ug/kg ND 334 11/16/22 07:42115 Fluorene ug/kg ND 334 11/16/22 07:42118 Hexachloro-1,3-butadiene ug/kg ND 334 11/16/22 07:42145 Hexachlorobenzene ug/kg ND 334 11/16/22 07:42131 Hexachlorocyclopentadiene ug/kg ND 334 11/16/22 07:42192 Hexachloroethane ug/kg ND 334 11/16/22 07:42128 Indeno(1,2,3-cd)pyrene ug/kg ND 334 11/16/22 07:42132 Isophorone ug/kg ND 334 11/16/22 07:42149 N-Nitroso-di-n-propylamine ug/kg ND 334 11/16/22 07:42126 N-Nitrosodimethylamine ug/kg ND 334 11/16/22 07:42112 N-Nitrosodiphenylamine ug/kg ND 334 11/16/22 07:42119 Naphthalene ug/kg ND 334 11/16/22 07:42114 Nitrobenzene ug/kg ND 334 11/16/22 07:42155 Pentachlorophenol ug/kg ND 669 11/16/22 07:42327 Phenanthrene ug/kg ND 334 11/16/22 07:42109 Phenol ug/kg ND 334 11/16/22 07:42149 Pyrene ug/kg ND 334 11/16/22 07:42136 Pyridine ug/kg ND 334 11/16/22 07:42105 2,4,6-Tribromophenol (S)%77 10-131 11/16/22 07:42 2-Fluorobiphenyl (S)%48 10-130 11/16/22 07:42 2-Fluorophenol (S)%47 10-130 11/16/22 07:42 Nitrobenzene-d5 (S)%47 10-130 11/16/22 07:42 Phenol-d6 (S)%45 10-130 11/16/22 07:42 Terphenyl-d14 (S)%90 10-130 11/16/22 07:42 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3836459LABORATORY CONTROL SAMPLE: LCSSpike 1,2,4-Trichlorobenzene ug/kg 10401660 63 43-130 1,2-Dichlorobenzene ug/kg 10301660 62 43-130 1,3-Dichlorobenzene ug/kg 10101660 61 43-130 1,4-Dichlorobenzene ug/kg 10101660 61 44-130 1-Methylnaphthalene ug/kg 11001660 66 47-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 36 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3836459LABORATORY CONTROL SAMPLE: LCSSpike 2,2'-Oxybis(1-chloropropane)ug/kg 8311660 50 29-130 2,4,5-Trichlorophenol ug/kg 13801660 83 47-130 2,4,6-Trichlorophenol ug/kg 13501660 81 47-130 2,4-Dichlorophenol ug/kg 11101660 67 45-130 2,4-Dimethylphenol ug/kg 13801660 83 45-130 2,4-Dinitrophenol ug/kg 76708310 92 27-140 2,4-Dinitrotoluene ug/kg 14201660 85 46-130 2,6-Dinitrotoluene ug/kg 14101660 85 48-130 2-Chloronaphthalene ug/kg 11801660 71 46-130 2-Chlorophenol ug/kg 10501660 63 43-130 2-Methylnaphthalene ug/kg 10701660 64 47-130 2-Methylphenol(o-Cresol)ug/kg 10301660 62 42-130 2-Nitroaniline ug/kg 26503320 80 41-130 2-Nitrophenol ug/kg 11001660 66 48-130 3&4-Methylphenol(m&p Cresol)ug/kg 10601660 64 39-130 3,3'-Dichlorobenzidine ug/kg 25003320 75 41-130 3-Nitroaniline ug/kg 28203320 85 37-130 4,6-Dinitro-2-methylphenol ug/kg 33803320 102 38-141 4-Bromophenylphenyl ether ug/kg 15101660 91 47-130 4-Chloro-3-methylphenol ug/kg 26003320 78 44-130 4-Chloroaniline ug/kg 21203320 64 41-130 4-Chlorophenylphenyl ether ug/kg 13301660 80 45-130 4-Nitroaniline ug/kg 25703320 77 42-130 4-Nitrophenol ug/kg 71108310 86 39-131 Acenaphthene ug/kg 12401660 75 49-130 Acenaphthylene ug/kg 12401660 75 50-130 Aniline ug/kg 8551660 51 38-130 Anthracene ug/kg 12801660 77 49-130 Benzo(a)anthracene ug/kg 14501660 87 51-130 Benzo(a)pyrene ug/kg 14601660 88 51-130 Benzo(b)fluoranthene ug/kg 15001660 90 49-130 Benzo(g,h,i)perylene ug/kg 12701660 77 48-140 Benzo(k)fluoranthene ug/kg 14801660 89 51-130 Benzoic Acid ug/kg 54208310 65 22-130 Benzyl alcohol ug/kg 20903320 63 43-130 bis(2-Chloroethoxy)methane ug/kg 10601660 64 43-130 bis(2-Chloroethyl) ether ug/kg 9851660 59 42-130 bis(2-Ethylhexyl)phthalate ug/kg 15901660 96 43-130 Butylbenzylphthalate ug/kg 16401660 99 44-131 Chrysene ug/kg 14101660 85 51-130 Di-n-butylphthalate ug/kg 14901660 90 46-130 Di-n-octylphthalate ug/kg 15801660 95 45-130 Dibenz(a,h)anthracene ug/kg 13201660 79 48-130 Dibenzofuran ug/kg 12901660 77 10-130 Diethylphthalate ug/kg 14101660 85 48-130 Dimethylphthalate ug/kg 13901660 84 48-130 Fluoranthene ug/kg 14001660 84 48-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 37 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3836459LABORATORY CONTROL SAMPLE: LCSSpike Fluorene ug/kg 13501660 81 48-130 Hexachloro-1,3-butadiene ug/kg 10501660 63 39-130 Hexachlorobenzene ug/kg 13701660 83 47-130 Hexachlorocyclopentadiene ug/kg 10901660 66 17-130 Hexachloroethane ug/kg 10101660 61 40-130 Indeno(1,2,3-cd)pyrene ug/kg 13401660 80 50-130 Isophorone ug/kg 11301660 68 41-130 N-Nitroso-di-n-propylamine ug/kg 10201660 61 36-130 N-Nitrosodimethylamine ug/kg 11001660 66 34-130 N-Nitrosodiphenylamine ug/kg 14501660 88 48-130 Naphthalene ug/kg 10401660 63 46-130 Nitrobenzene ug/kg 10601660 64 39-130 Pentachlorophenol ug/kg 33703320 101 42-130 Phenanthrene ug/kg 14201660 86 50-130 Phenol ug/kg 10601660 64 42-130 Pyrene ug/kg 15301660 92 50-130 Pyridine ug/kg 8821660 53 26-130 2,4,6-Tribromophenol (S)%98 10-131 2-Fluorobiphenyl (S)%68 10-130 2-Fluorophenol (S)%64 10-130 Nitrobenzene-d5 (S)%62 10-130 Phenol-d6 (S)%63 10-130 Terphenyl-d14 (S)%93 10-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3836460MATRIX SPIKE SAMPLE: MSSpike Result 92636096001 1,2,4-Trichlorobenzene ug/kg 17402910 60 16-130ND 1,2-Dichlorobenzene ug/kg 17102910 59 19-130ND 1,3-Dichlorobenzene ug/kg 17002910 58 19-130ND 1,4-Dichlorobenzene ug/kg 17102910 59 20-130ND 1-Methylnaphthalene ug/kg 19102910 66 19-130ND 2,2'-Oxybis(1-chloropropane)ug/kg 14302910 49 10-130ND 2,4,5-Trichlorophenol ug/kg 24002910 82 19-130ND 2,4,6-Trichlorophenol ug/kg 23402910 80 18-130ND 2,4-Dichlorophenol ug/kg 19502910 67 16-130ND 2,4-Dimethylphenol ug/kg 23802910 82 10-130ND 2,4-Dinitrophenol ug/kg 1430014500 99 10-143ND 2,4-Dinitrotoluene ug/kg 25502910 88 19-130ND 2,6-Dinitrotoluene ug/kg 25302910 87 22-130ND 2-Chloronaphthalene ug/kg 20002910 69 18-130ND 2-Chlorophenol ug/kg 17802910 61 20-130ND 2-Methylnaphthalene ug/kg 18502910 64 18-130ND 2-Methylphenol(o-Cresol)ug/kg 17802910 61 13-130ND 2-Nitroaniline ug/kg 51705820 89 18-130ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 38 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3836460MATRIX SPIKE SAMPLE: MSSpike Result 92636096001 2-Nitrophenol ug/kg 18802910 65 19-130ND 3&4-Methylphenol(m&p Cresol)ug/kg 18602910 64 13-130ND 3,3'-Dichlorobenzidine ug/kg 47405820 82 10-130ND 3-Nitroaniline ug/kg 50905820 87 22-130ND 4,6-Dinitro-2-methylphenol ug/kg 60805820 105 10-144ND 4-Bromophenylphenyl ether ug/kg 26102910 90 18-130ND 4-Chloro-3-methylphenol ug/kg 47205820 81 16-130ND 4-Chloroaniline ug/kg 37805820 65 17-130ND 4-Chlorophenylphenyl ether ug/kg 23502910 81 17-130ND 4-Nitroaniline ug/kg 47905820 82 21-130ND 4-Nitrophenol ug/kg 1310014500 90 13-131ND Acenaphthene ug/kg 21702910 75 20-130ND Acenaphthylene ug/kg 21702910 74 21-130ND Aniline ug/kg 14802910 51 10-130ND Anthracene ug/kg 22802910 78 19-130ND Benzo(a)anthracene ug/kg 25802910 89 17-130ND Benzo(a)pyrene ug/kg 25902910 89 14-130ND Benzo(b)fluoranthene ug/kg 26902910 93 11-134ND Benzo(g,h,i)perylene ug/kg 23602910 81 12-130ND Benzo(k)fluoranthene ug/kg 26402910 91 15-130ND Benzoic Acid ug/kg 912014500 63 10-130ND Benzyl alcohol ug/kg 37005820 64 20-130ND bis(2-Chloroethoxy)methane ug/kg 18602910 64 16-130ND bis(2-Chloroethyl) ether ug/kg 17102910 59 18-130ND bis(2-Ethylhexyl)phthalate ug/kg 28302910 97 11-130ND Butylbenzylphthalate ug/kg 28902910 99 10-130ND Chrysene ug/kg 25202910 87 17-130ND Di-n-butylphthalate ug/kg 26602910 92 16-130ND Di-n-octylphthalate ug/kg 27902910 96 16-130ND Dibenz(a,h)anthracene ug/kg 23902910 82 13-130ND Dibenzofuran ug/kg 22402910 77 19-130ND Diethylphthalate ug/kg 24902910 86 22-130ND Dimethylphthalate ug/kg 24702910 85 23-130ND Fluoranthene ug/kg 24902910 86 14-130ND Fluorene ug/kg 23802910 82 19-130ND Hexachloro-1,3-butadiene ug/kg 16902910 58 12-130ND Hexachlorobenzene ug/kg 23902910 82 17-130ND Hexachlorocyclopentadiene ug/kg 17502910 60 10-130ND Hexachloroethane ug/kg 16802910 58 14-130ND Indeno(1,2,3-cd)pyrene ug/kg 24302910 84 13-130ND Isophorone ug/kg 20202910 69 17-130ND N-Nitroso-di-n-propylamine ug/kg 18402910 63 10-130ND N-Nitrosodimethylamine ug/kg 17902910 62 16-130ND N-Nitrosodiphenylamine ug/kg 25402910 87 19-130ND Naphthalene ug/kg 17702910 61 18-130ND Nitrobenzene ug/kg 18202910 63 15-130ND Pentachlorophenol ug/kg 59505820 102 10-130ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 39 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3836460MATRIX SPIKE SAMPLE: MSSpike Result 92636096001 Phenanthrene ug/kg 25002910 86 17-130ND Phenol ug/kg 17902910 62 15-130ND Pyrene ug/kg 27002910 93 31-130ND Pyridine ug/kg 12802910 44 10-130ND 2,4,6-Tribromophenol (S)%86 10-131 2-Fluorobiphenyl (S)%55 10-130 2-Fluorophenol (S)%58 10-130 Nitrobenzene-d5 (S)%58 10-130 Phenol-d6 (S)%59 10-130 Terphenyl-d14 (S)%66 10-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92636096002 3836461SAMPLE DUPLICATE: 1,2,4-Trichlorobenzene ug/kg ND 30ND 1,2-Dichlorobenzene ug/kg ND 30ND 1,3-Dichlorobenzene ug/kg ND 30ND 1,4-Dichlorobenzene ug/kg ND 30ND 1-Methylnaphthalene ug/kg ND 30ND 2,2'-Oxybis(1-chloropropane)ug/kg ND 30ND 2,4,5-Trichlorophenol ug/kg ND 30ND 2,4,6-Trichlorophenol ug/kg ND 30ND 2,4-Dichlorophenol ug/kg ND 30ND 2,4-Dimethylphenol ug/kg ND 30ND 2,4-Dinitrophenol ug/kg ND 30ND 2,4-Dinitrotoluene ug/kg ND 30ND 2,6-Dinitrotoluene ug/kg ND 30ND 2-Chloronaphthalene ug/kg ND 30ND 2-Chlorophenol ug/kg ND 30ND 2-Methylnaphthalene ug/kg ND 30ND 2-Methylphenol(o-Cresol)ug/kg ND 30ND 2-Nitroaniline ug/kg ND 30ND 2-Nitrophenol ug/kg ND 30ND 3&4-Methylphenol(m&p Cresol)ug/kg ND 30ND 3,3'-Dichlorobenzidine ug/kg ND 30ND 3-Nitroaniline ug/kg ND 30ND 4,6-Dinitro-2-methylphenol ug/kg ND 30ND 4-Bromophenylphenyl ether ug/kg ND 30ND 4-Chloro-3-methylphenol ug/kg ND 30ND 4-Chloroaniline ug/kg ND 30ND 4-Chlorophenylphenyl ether ug/kg ND 30ND 4-Nitroaniline ug/kg ND 30ND 4-Nitrophenol ug/kg ND 30ND Acenaphthene ug/kg ND 30ND Acenaphthylene ug/kg ND 30ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 40 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92636096002 3836461SAMPLE DUPLICATE: Aniline ug/kg ND 30ND Anthracene ug/kg ND 30ND Benzo(a)anthracene ug/kg ND 30ND Benzo(a)pyrene ug/kg ND 30ND Benzo(b)fluoranthene ug/kg ND 30ND Benzo(g,h,i)perylene ug/kg ND 30ND Benzo(k)fluoranthene ug/kg ND 30ND Benzoic Acid ug/kg ND 30ND Benzyl alcohol ug/kg ND 30ND bis(2-Chloroethoxy)methane ug/kg ND 30ND bis(2-Chloroethyl) ether ug/kg ND 30ND bis(2-Ethylhexyl)phthalate ug/kg ND 30ND Butylbenzylphthalate ug/kg ND 30ND Chrysene ug/kg ND 30ND Di-n-butylphthalate ug/kg ND 30ND Di-n-octylphthalate ug/kg ND 30ND Dibenz(a,h)anthracene ug/kg ND 30ND Dibenzofuran ug/kg ND 30ND Diethylphthalate ug/kg ND 30ND Dimethylphthalate ug/kg ND 30ND Fluoranthene ug/kg ND 30ND Fluorene ug/kg ND 30ND Hexachloro-1,3-butadiene ug/kg ND 30ND Hexachlorobenzene ug/kg ND 30ND Hexachlorocyclopentadiene ug/kg ND 30ND Hexachloroethane ug/kg ND 30ND Indeno(1,2,3-cd)pyrene ug/kg ND 30ND Isophorone ug/kg ND 30ND N-Nitroso-di-n-propylamine ug/kg ND 30ND N-Nitrosodimethylamine ug/kg ND 30ND N-Nitrosodiphenylamine ug/kg ND 30ND Naphthalene ug/kg ND 30ND Nitrobenzene ug/kg ND 30ND Pentachlorophenol ug/kg ND 30ND Phenanthrene ug/kg ND 30ND Phenol ug/kg ND 30ND Pyrene ug/kg ND 30ND Pyridine ug/kg ND 30ND 2,4,6-Tribromophenol (S)%6269 2-Fluorobiphenyl (S)%4140 2-Fluorophenol (S)%4945 Nitrobenzene-d5 (S)%5248 Phenol-d6 (S)%4844 Terphenyl-d14 (S)%3547 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 41 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 736155 MADEP EPH MADEP EPH MADEP EPH NC Soil Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92635127003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3831172 Associated Lab Samples:92635127003 Matrix:Solid AnalyzedMDL Aliphatic (C09-C18)mg/kg ND 10.2 N211/11/22 08:4410.2 Aliphatic (C19-C36)mg/kg ND 10.2 N211/11/22 08:4410.2 Aromatic (C11-C22)mg/kg ND 10.2 N211/11/22 08:4410.2 1-Chlorooctadecane (S)%98 40-140 11/11/22 08:44 2-Bromonaphthalene (S)%113 40-140 11/11/22 08:44 2-Fluorobiphenyl (S)%112 40-140 11/11/22 08:44 o-Terphenyl (S)%86 40-140 11/11/22 08:44 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3831173LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 3831174 Aliphatic (C09-C18)mg/kg ND N210.1 55 40-14052ND 50 Aliphatic (C19-C36)mg/kg 11.8 N213.4 88 40-1407710.3 14 50 Aromatic (C11-C22)mg/kg 23.2 N228.5 81 40-1407722.0 5 50 1-Chlorooctadecane (S)%92 40-14079 2-Bromonaphthalene (S)%113 40-140107 2-Fluorobiphenyl (S)%113 40-140107 o-Terphenyl (S)%85 40-14081 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 42 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 735694 SW-846 SW-846 Dry Weight/Percent Moisture Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92635127001, 92635127002, 92635127003 Parameter Units Dup Result Max RPD QualifiersRPDResult 92634397015 3828953SAMPLE DUPLICATE: Percent Moisture %5.0 N20255.0 Parameter Units Dup Result Max RPD QualifiersRPDResult 92635371005 3828954SAMPLE DUPLICATE: Percent Moisture %17.2 N212517.4 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 43 of 49 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92635127 44682-7940 Guilford College Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 1957902 SM 2540 G SM 2540G Total Solids 2540 G-2011 Laboratory:Pace National - Mt. Juliet Associated Lab Samples:92635127001, 92635127002, 92635127003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3859994-1 Associated Lab Samples:92635127001, 92635127002, 92635127003 Matrix:Solid AnalyzedMDL Total Solids %0.00200 11/11/22 07:47 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3859994-2LABORATORY CONTROL SAMPLE: LCSSpike Total Solids %50.050.0 100 85.0-115 Parameter Units Dup Result Max RPD QualifiersRPDResult L1553936-02 R3859994-3SAMPLE DUPLICATE: Total Solids %98.0 0.0428 1098.0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 44 of 49 #=QL# QUALIFIERS Pace Project No.: Project: 92635127 44682-7940 Guilford College DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS Common Laboratory Contaminant.C9 The precision between the sample and sample duplicate exceeded laboratory control limits.D6 Analyte concentration exceeded the calibration range. The reported result is estimated.E The recalculated concentration of the calibration standard(s) did not meet method acceptance criteria; this result should be considered an estimated value.IK Analyte detected below the reporting limit, therefore result is an estimate. This qualifier is also used for all TICs.J Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.M1 The lab does not hold NELAC/TNI accreditation for this parameter but other accreditations/certifications may apply. A complete list of accreditations/certifications is available upon request.N2 Matrix spike recovery was outside laboratory control limits due to a parent sample concentration notably higher than the spike level.P6 The continuing calibration verification was above the method acceptance limit. Any detection for the analyte in the associated samples may have a high bias.v1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 45 of 49 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92635127 44682-7940 Guilford College Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92635127003 736155 736437DE-3 MADEP EPH MADEP EPH 92635127001 1958808 1958808DE-1 MADEPV MADEP VPH 92635127002 1960505 1960505DE-2 MADEPV MADEP VPH 92635127003 1960505 1960505DE-3 MADEPV MADEP VPH 92635127003 737176 737356DE-3 EPA 3546 EPA 8270E 92635127001 736340 736766DE-1 EPA 5035A/5030B EPA 8260D 92635127002 736012 736205DE-2 EPA 5035A/5030B EPA 8260D 92635127003 736012 736205DE-3 EPA 5035A/5030B EPA 8260D 92635127001 735694DE-1 SW-846 92635127002 735694DE-2 SW-846 92635127003 735694DE-3 SW-846 92635127001 1957902 1957902DE-1 SM 2540 G SM 2540G 92635127002 1957902 1957902DE-2 SM 2540 G SM 2540G 92635127003 1957902 1957902DE-3 SM 2540 G SM 2540G REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/18/2022 04:31 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 46 of 49 Page 47 of 49 Page 48 of 49 Page 49 of 49 #=CL# December 29, 2022 LIMS USE: FR - NATHAN PINSKER LIMS OBJECT ID: 92638346 92638346 Project: Pace Project No.: RE: Nathan Pinsker AECOM 5438 Wade Park Blvd Suite 200 Raleigh, NC 27607 SPEEDWAY 7940 GUILFORD COLLEGE Dear Nathan Pinsker: Enclosed are the analytical results for sample(s) received by the laboratory on November 22, 2022. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace National - Mt. Juliet • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Bonnie Vang bonnie.vang@pacelabs.com Project Manager (704)875-9092 Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 69 #=CP# CERTIFICATIONS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Pace Analytical Services National 12065 Lebanon Road, Mt. Juliet, TN 37122 Alabama Certification #: 40660 Alaska Certification 17-026 Arizona Certification #: AZ0612 Arkansas Certification #: 88-0469 California Certification #: 2932 Canada Certification #: 1461.01 Colorado Certification #: TN00003 Connecticut Certification #: PH-0197 DOD Certification: #1461.01 EPA# TN00003 Florida Certification #: E87487 Georgia DW Certification #: 923 Georgia Certification: NELAP Idaho Certification #: TN00003 Illinois Certification #: 200008 Indiana Certification #: C-TN-01 Iowa Certification #: 364 Kansas Certification #: E-10277 Kentucky UST Certification #: 16 Kentucky Certification #: 90010 Louisiana Certification #: AI30792 Louisiana DW Certification #: LA180010 Maine Certification #: TN0002 Maryland Certification #: 324 Massachusetts Certification #: M-TN003 Michigan Certification #: 9958 Minnesota Certification #: 047-999-395 Mississippi Certification #: TN00003 Missouri Certification #: 340 Montana Certification #: CERT0086 Nebraska Certification #: NE-OS-15-05 Nevada Certification #: TN-03-2002-34 New Hampshire Certification #: 2975 New Jersey Certification #: TN002 New Mexico DW Certification New York Certification #: 11742 North Carolina Aquatic Toxicity Certification #: 41 North Carolina Drinking Water Certification #: 21704 North Carolina Environmental Certificate #: 375 North Dakota Certification #: R-140 Ohio VAP Certification #: CL0069 Oklahoma Certification #: 9915 Oregon Certification #: TN200002 Pennsylvania Certification #: 68-02979 Rhode Island Certification #: LAO00356 South Carolina Certification #: 84004 South Dakota Certification Tennessee DW/Chem/Micro Certification #: 2006 Texas Certification #: T 104704245-17-14 Texas Mold Certification #: LAB0152 USDA Soil Permit #: P330-15-00234 Utah Certification #: TN00003 Virginia Certification #: VT2006 Vermont Dept. of Health: ID# VT-2006 Virginia Certification #: 460132 Washington Certification #: C847 West Virginia Certification #: 233 Wisconsin Certification #: 998093910 Wyoming UST Certification #: via A2LA 2926.01 A2LA-ISO 17025 Certification #: 1461.01 A2LA-ISO 17025 Certification #: 1461.02 AIHA-LAP/LLC EMLAP Certification #:100789 Pace Analytical Services Charlotte South Carolina Laboratory ID: 99006 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Laboratory ID: 99006 South Carolina Certification #: 99006001 South Carolina Drinking Water Cert. #: 99006003 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana DoH Drinking Water #: LA029 Virginia/VELAP Certification #: 460221 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 69 #=SS# SAMPLE SUMMARY Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Lab ID Sample ID Matrix Date Collected Date Received 92638346001 D-1 Solid 11/21/22 11:45 11/22/22 11:55 92638346002 D-2 Solid 11/21/22 12:25 11/22/22 11:55 92638346003 D-3 Solid 11/21/22 13:00 11/22/22 11:55 92638346004 D-4 Solid 11/21/22 13:20 11/22/22 11:55 92638346005 D-5 Solid 11/21/22 14:00 11/22/22 11:55 92638346006 D-6 Solid 11/21/22 15:15 11/22/22 11:55 92638346007 D-7 Solid 11/21/22 15:30 11/22/22 11:55 92638346008 PL-1 Solid 11/21/22 17:30 11/22/22 11:55 92638346009 PL-2 Solid 11/21/22 21:00 11/22/22 11:55 92638346010 PL-3 Solid 11/21/22 21:05 11/22/22 11:55 92638346011 PL-4 Solid 11/21/22 21:10 11/22/22 11:55 92638346012 PL-5 Solid 11/21/22 21:15 11/22/22 11:55 92638346013 PL-6 Solid 11/21/22 21:20 11/22/22 11:55 92638346014 PL-7 Solid 11/21/22 21:25 11/22/22 11:55 92638346015 PL-8 Solid 11/21/22 17:30 11/22/22 11:55 92638346016 PL-8 (RISK)Solid 11/21/22 17:30 11/22/22 11:55 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 69 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92638346001 D-1 MADEP VPH 6 PANACG, JAH EPA 8015C 2 PASI-CTEG EPA 8260D 70 PASI-CLMB SW-846 1 PASI-CKDF SM 2540G 1 PANCMK 92638346002 D-2 EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346003 D-3 EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346004 D-4 EPA 8015C 2 PASI-CBAJ EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346005 D-5 EPA 8015C 2 PASI-CBAJ EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346006 D-6 EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346007 D-7 EPA 8015C 2 PASI-CBAJ EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346008 PL-1 EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346009 PL-2 EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346010 PL-3 EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346011 PL-4 EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346012 PL-5 EPA 8015C 2 PASI-CBAJ EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346013 PL-6 EPA 8015C 2 PASI-CBAJ EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346014 PL-7 EPA 8015C 2 PASI-CBAJ EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 69 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92638346015 PL-8 EPA 8015C 2 PASI-CBAJ EPA 8015C 2 PASI-CTEG SW-846 1 PASI-CKDF 92638346016 PL-8 (RISK)MADEP EPH 7 PASI-CSEM MADEP VPH 6 PANACG, JAH EPA 8270E 75 PASI-CBPJ EPA 8260D 70 PASI-CLMB SW-846 1 PASI-CKDF PAN = Pace National - Mt. Juliet PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 69 #=HO# SUMMARY OF DETECTION Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Parameters AnalyzedResult Lab Sample ID Report Limit QualifiersUnitsMethod Client Sample ID 92638346001 D-1 Aliphatic (C05-C08)191 mg/kg 12/13/22 10:068.59MADEP VPH Aliphatic (C09-C12)519 mg/kg 12/13/22 10:068.59MADEP VPH Aromatic (C09-C10),Unadjusted 392 mg/kg 12/17/22 16:1542.9MADEP VPH Total VPH 1100 mg/kg 12/17/22 16:1542.9MADEP VPH Gas Range Organics (C6-C10)1970 mg/kg 11/28/22 17:5829.8EPA 8015C Benzene 0.17 mg/kg 12/07/22 02:23 H1,H20.12EPA 8260D Ethylbenzene 18.0 mg/kg 12/07/22 02:23 H1,H20.12EPA 8260D Isopropylbenzene (Cumene)2.1 mg/kg 12/07/22 02:23 H1,H20.12EPA 8260D Methyl-tert-butyl ether 0.095J mg/kg 12/07/22 02:23 H1,H20.12EPA 8260D Naphthalene 16.2 mg/kg 12/07/22 02:23 H1,H20.12EPA 8260D n-Propylbenzene 9.2 mg/kg 12/07/22 02:23 H1,H20.12EPA 8260D Toluene 1.8 mg/kg 12/07/22 02:23 H1,H20.12EPA 8260D 1,2,4-Trimethylbenzene 68.0 mg/kg 12/07/22 02:23 H1,H20.12EPA 8260D 1,3,5-Trimethylbenzene 21.2 mg/kg 12/07/22 02:23 H1,H20.12EPA 8260D Xylene (Total)87.9 mg/kg 12/07/22 02:230.23EPA 8260D m&p-Xylene 61.0 mg/kg 12/07/22 02:23 H1,H20.23EPA 8260D o-Xylene 26.9 mg/kg 12/07/22 02:23 H1,H20.12EPA 8260D Percent Moisture 24.8 %11/28/22 17:55 N20.10SW-846 Total Solids 73.6 %12/12/22 14:38SM 2540G 92638346002 D-2 Gas Range Organics (C6-C10)265 mg/kg 11/25/22 16:218.9EPA 8015C Percent Moisture 24.7 %11/28/22 17:55 N20.10SW-846 92638346003 D-3 Gas Range Organics (C6-C10)162 mg/kg 11/25/22 16:4610.1EPA 8015C Percent Moisture 23.8 %11/28/22 17:55 N20.10SW-846 92638346004 D-4 Gas Range Organics (C6-C10)7.7J mg/kg 11/25/22 17:12 C89.6EPA 8015C Percent Moisture 23.0 %11/29/22 13:54 N20.10SW-846 92638346005 D-5 Diesel Range Organics(C10-C28)6.5J mg/kg 12/01/22 12:367.0EPA 8015C Percent Moisture 28.2 %11/29/22 13:54 N20.10SW-846 92638346006 D-6 Percent Moisture 22.6 %11/29/22 13:54 N20.10SW-846 92638346007 D-7 Percent Moisture 25.2 %11/29/22 13:54 N20.10SW-846 92638346008 PL-1 Gas Range Organics (C6-C10)4.1J mg/kg 11/25/22 18:5510.5EPA 8015C Percent Moisture 22.7 %11/29/22 13:54 N20.10SW-846 92638346009 PL-2 Gas Range Organics (C6-C10)3.5J mg/kg 11/25/22 19:219.5EPA 8015C Percent Moisture 21.0 %11/29/22 13:54 N20.10SW-846 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 69 #=HO# SUMMARY OF DETECTION Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Parameters AnalyzedResult Lab Sample ID Report Limit QualifiersUnitsMethod Client Sample ID 92638346010 PL-3 Percent Moisture 23.0 %11/29/22 13:55 N20.10SW-846 92638346011 PL-4 Percent Moisture 22.8 %11/29/22 13:55 N20.10SW-846 92638346012 PL-5 Gas Range Organics (C6-C10)7.0J mg/kg 11/25/22 20:389.0EPA 8015C Percent Moisture 21.4 %11/29/22 13:55 N20.10SW-846 92638346013 PL-6 Gas Range Organics (C6-C10)3.9J mg/kg 11/25/22 21:04 C810EPA 8015C Percent Moisture 19.5 %11/29/22 13:55 N20.10SW-846 92638346014 PL-7 Diesel Range Organics(C10-C28)16.2 mg/kg 12/01/22 13:096.4EPA 8015C Gas Range Organics (C6-C10)13.7 mg/kg 11/25/22 21:2910.4EPA 8015C Percent Moisture 21.4 %11/29/22 13:55 N20.10SW-846 92638346015 PL-8 Diesel Range Organics(C10-C28)286 mg/kg 12/01/22 13:096.9EPA 8015C Gas Range Organics (C6-C10)1250 mg/kg 11/28/22 17:3322.3EPA 8015C Percent Moisture 26.6 %11/29/22 13:55 N20.10SW-846 92638346016 PL-8 (RISK) Aliphatic (C09-C18)73.4 mg/kg 12/07/22 08:43 N213.8MADEP EPH Aromatic (C11-C22)66.0 mg/kg 12/07/22 08:43 N213.8MADEP EPH Aliphatic (C05-C08)125 mg/kg 12/13/22 10:398.79MADEP VPH Aliphatic (C09-C12)369 mg/kg 12/13/22 10:398.79MADEP VPH Aromatic (C09-C10),Unadjusted 323 mg/kg 12/17/22 15:4243.9MADEP VPH Total VPH 817 mg/kg 12/17/22 15:4243.9MADEP VPH 1-Methylnaphthalene 3360 ug/kg 12/05/22 18:40454EPA 8270E 2-Methylnaphthalene 7150 ug/kg 12/06/22 09:18909EPA 8270E Naphthalene 4480 ug/kg 12/06/22 09:18909EPA 8270E Acetone 0.57J mg/kg 12/05/22 17:151.6EPA 8260D n-Butylbenzene 3.3 mg/kg 12/05/22 17:150.082EPA 8260D Chlorobenzene 0.15 mg/kg 12/05/22 17:150.082EPA 8260D Ethylbenzene 3.6 mg/kg 12/05/22 17:150.082EPA 8260D Isopropylbenzene (Cumene)1.4 mg/kg 12/05/22 17:150.082EPA 8260D Naphthalene 9.9 mg/kg 12/05/22 17:150.082EPA 8260D n-Propylbenzene 6.0 mg/kg 12/05/22 17:150.082EPA 8260D Toluene 0.12 mg/kg 12/05/22 17:150.082EPA 8260D 1,2,4-Trimethylbenzene 38.0 mg/kg 12/05/22 17:150.082EPA 8260D 1,3,5-Trimethylbenzene 8.1 mg/kg 12/05/22 17:150.082EPA 8260D Xylene (Total)5.2 mg/kg 12/05/22 17:150.16EPA 8260D m&p-Xylene 4.4 mg/kg 12/05/22 17:150.16EPA 8260D o-Xylene 0.83 mg/kg 12/05/22 17:150.082EPA 8260D Percent Moisture 26.9 %12/08/22 13:49 N20.10SW-846 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:D-1 Lab ID:92638346001 Collected:11/21/22 11:45 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)191 mg/kg 12/13/22 10:0611/21/22 11:458.59 2.87 1 Aliphatic (C09-C12)519 mg/kg 12/13/22 10:0611/21/22 11:458.59 2.87 1 Aromatic (C09-C10),Unadjusted 392 mg/kg 12/17/22 16:15 TPHC9C10A11/21/22 11:4542.9 14.3 5 Total VPH 1100 mg/kg 12/17/22 16:15 VPH11/21/22 11:4542.9 14.3 5 Surrogates 2,5-Dibromotoluene (FID)120 %12/13/22 10:06 615-59-8FID11/21/22 11:4570.0-130 1 2,5-Dibromotoluene (FID)113 %12/17/22 16:15 615-59-8FID11/21/22 11:4570.0-130 5 2,5-Dibromotoluene (PID)83.0 %12/13/22 10:06 615-59-8PID11/21/22 11:4570.0-130 1 2,5-Dibromotoluene (PID)90.1 %12/17/22 16:15 615-59-8PID11/21/22 11:4570.0-130 5 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)1970 mg/kg 11/28/22 17:5811/28/22 11:2529.8 8.2 2.5 Surrogates 4-Bromofluorobenzene (S)127 %11/28/22 17:58 460-00-411/28/22 11:2566-130 2.5 Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles Acetone ND mg/kg 12/07/22 02:23 67-64-1 H1,H212/06/22 20:422.3 0.75 12.5 Benzene 0.17 mg/kg 12/07/22 02:23 71-43-2 H1,H212/06/22 20:420.12 0.046 12.5 Bromobenzene ND mg/kg 12/07/22 02:23 108-86-1 H1,H212/06/22 20:420.12 0.038 12.5 Bromochloromethane ND mg/kg 12/07/22 02:23 74-97-5 H1,H212/06/22 20:420.12 0.035 12.5 Bromodichloromethane ND mg/kg 12/07/22 02:23 75-27-4 H1,H212/06/22 20:420.12 0.045 12.5 Bromoform ND mg/kg 12/07/22 02:23 75-25-2 H1,H212/06/22 20:420.12 0.041 12.5 Bromomethane ND mg/kg 12/07/22 02:23 74-83-9 H1,H2, IK12/06/22 20:420.23 0.18 12.5 2-Butanone (MEK)ND mg/kg 12/07/22 02:23 78-93-3 H1,H212/06/22 20:422.3 0.56 12.5 n-Butylbenzene ND mg/kg 12/07/22 02:23 104-51-8 H1,H212/06/22 20:420.12 0.055 12.5 sec-Butylbenzene ND mg/kg 12/07/22 02:23 135-98-8 H1,H212/06/22 20:420.12 0.051 12.5 tert-Butylbenzene ND mg/kg 12/07/22 02:23 98-06-6 H1,H212/06/22 20:420.12 0.042 12.5 Carbon tetrachloride ND mg/kg 12/07/22 02:23 56-23-5 H1,H212/06/22 20:420.12 0.044 12.5 Chlorobenzene ND mg/kg 12/07/22 02:23 108-90-7 H1,H212/06/22 20:420.12 0.022 12.5 Chloroethane ND mg/kg 12/07/22 02:23 75-00-3 H1,H212/06/22 20:420.23 0.090 12.5 Chloroform ND mg/kg 12/07/22 02:23 67-66-3 H1,H212/06/22 20:420.12 0.071 12.5 Chloromethane ND mg/kg 12/07/22 02:23 74-87-3 H1,H212/06/22 20:420.23 0.098 12.5 2-Chlorotoluene ND mg/kg 12/07/22 02:23 95-49-8 H1,H212/06/22 20:420.12 0.041 12.5 4-Chlorotoluene ND mg/kg 12/07/22 02:23 106-43-4 H1,H212/06/22 20:420.12 0.021 12.5 1,2-Dibromo-3-chloropropane ND mg/kg 12/07/22 02:23 96-12-8 H1,H212/06/22 20:420.12 0.045 12.5 Dibromochloromethane ND mg/kg 12/07/22 02:23 124-48-1 H1,H212/06/22 20:420.12 0.066 12.5 1,2-Dibromoethane (EDB)ND mg/kg 12/07/22 02:23 106-93-4 H1,H212/06/22 20:420.12 0.051 12.5 Dibromomethane ND mg/kg 12/07/22 02:23 74-95-3 H1,H212/06/22 20:420.12 0.025 12.5 1,2-Dichlorobenzene ND mg/kg 12/07/22 02:23 95-50-1 H1,H212/06/22 20:420.12 0.042 12.5 1,3-Dichlorobenzene ND mg/kg 12/07/22 02:23 541-73-1 H1,H212/06/22 20:420.12 0.036 12.5 1,4-Dichlorobenzene ND mg/kg 12/07/22 02:23 106-46-7 H1,H212/06/22 20:420.12 0.030 12.5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:D-1 Lab ID:92638346001 Collected:11/21/22 11:45 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles Dichlorodifluoromethane ND mg/kg 12/07/22 02:23 75-71-8 H1,H2, v112/06/22 20:420.23 0.051 12.5 1,1-Dichloroethane ND mg/kg 12/07/22 02:23 75-34-3 H1,H212/06/22 20:420.12 0.048 12.5 1,2-Dichloroethane ND mg/kg 12/07/22 02:23 107-06-2 H1,H212/06/22 20:420.12 0.077 12.5 1,1-Dichloroethene ND mg/kg 12/07/22 02:23 75-35-4 H1,H212/06/22 20:420.12 0.048 12.5 cis-1,2-Dichloroethene ND mg/kg 12/07/22 02:23 156-59-2 H1,H212/06/22 20:420.12 0.040 12.5 trans-1,2-Dichloroethene ND mg/kg 12/07/22 02:23 156-60-5 H1,H212/06/22 20:420.12 0.041 12.5 1,2-Dichloropropane ND mg/kg 12/07/22 02:23 78-87-5 H1,H212/06/22 20:420.12 0.035 12.5 1,3-Dichloropropane ND mg/kg 12/07/22 02:23 142-28-9 H1,H212/06/22 20:420.12 0.036 12.5 2,2-Dichloropropane ND mg/kg 12/07/22 02:23 594-20-7 H1,H2, IK,v112/06/22 20:420.12 0.038 12.5 1,1-Dichloropropene ND mg/kg 12/07/22 02:23 563-58-6 H1,H212/06/22 20:420.12 0.056 12.5 cis-1,3-Dichloropropene ND mg/kg 12/07/22 02:23 10061-01-5 H1,H212/06/22 20:420.12 0.032 12.5 trans-1,3-Dichloropropene ND mg/kg 12/07/22 02:23 10061-02-6 H1,H212/06/22 20:420.12 0.040 12.5 Diisopropyl ether ND mg/kg 12/07/22 02:23 108-20-3 H1,H212/06/22 20:420.12 0.031 12.5 Ethylbenzene 18.0 mg/kg 12/07/22 02:23 100-41-4 H1,H212/06/22 20:420.12 0.054 12.5 Hexachloro-1,3-butadiene ND mg/kg 12/07/22 02:23 87-68-3 H1,H212/06/22 20:420.23 0.19 12.5 2-Hexanone ND mg/kg 12/07/22 02:23 591-78-6 H1,H212/06/22 20:421.2 0.11 12.5 Isopropylbenzene (Cumene)2.1 mg/kg 12/07/22 02:23 98-82-8 H1,H212/06/22 20:420.12 0.040 12.5 p-Isopropyltoluene ND mg/kg 12/07/22 02:23 99-87-6 H1,H212/06/22 20:420.12 0.057 12.5 Methylene Chloride ND mg/kg 12/07/22 02:23 75-09-2 H1,H2, IK12/06/22 20:420.47 0.32 12.5 4-Methyl-2-pentanone (MIBK)ND mg/kg 12/07/22 02:23 108-10-1 H1,H212/06/22 20:421.2 0.11 12.5 Methyl-tert-butyl ether 0.095J mg/kg 12/07/22 02:23 1634-04-4 H1,H212/06/22 20:420.12 0.044 12.5 Naphthalene 16.2 mg/kg 12/07/22 02:23 91-20-3 H1,H212/06/22 20:420.12 0.061 12.5 n-Propylbenzene 9.2 mg/kg 12/07/22 02:23 103-65-1 H1,H212/06/22 20:420.12 0.042 12.5 Styrene ND mg/kg 12/07/22 02:23 100-42-5 H1,H212/06/22 20:420.12 0.031 12.5 1,1,1,2-Tetrachloroethane ND mg/kg 12/07/22 02:23 630-20-6 H1,H212/06/22 20:420.12 0.045 12.5 1,1,2,2-Tetrachloroethane ND mg/kg 12/07/22 02:23 79-34-5 H1,H212/06/22 20:420.12 0.031 12.5 Tetrachloroethene ND mg/kg 12/07/22 02:23 127-18-4 H1,H212/06/22 20:420.12 0.037 12.5 Toluene 1.8 mg/kg 12/07/22 02:23 108-88-3 H1,H212/06/22 20:420.12 0.033 12.5 1,2,3-Trichlorobenzene ND mg/kg 12/07/22 02:23 87-61-6 H1,H212/06/22 20:420.12 0.094 12.5 1,2,4-Trichlorobenzene ND mg/kg 12/07/22 02:23 120-82-1 H1,H212/06/22 20:420.12 0.098 12.5 1,1,1-Trichloroethane ND mg/kg 12/07/22 02:23 71-55-6 H1,H212/06/22 20:420.12 0.061 12.5 1,1,2-Trichloroethane ND mg/kg 12/07/22 02:23 79-00-5 H1,H212/06/22 20:420.12 0.039 12.5 Trichloroethene ND mg/kg 12/07/22 02:23 79-01-6 H1,H212/06/22 20:420.12 0.030 12.5 Trichlorofluoromethane ND mg/kg 12/07/22 02:23 75-69-4 H1,H212/06/22 20:420.12 0.064 12.5 1,2,3-Trichloropropane ND mg/kg 12/07/22 02:23 96-18-4 H1,H212/06/22 20:420.12 0.059 12.5 1,2,4-Trimethylbenzene 68.0 mg/kg 12/07/22 02:23 95-63-6 H1,H212/06/22 20:420.12 0.032 12.5 1,3,5-Trimethylbenzene 21.2 mg/kg 12/07/22 02:23 108-67-8 H1,H212/06/22 20:420.12 0.039 12.5 Vinyl acetate ND mg/kg 12/07/22 02:23 108-05-4 H1,H2, IK12/06/22 20:421.2 0.085 12.5 Vinyl chloride ND mg/kg 12/07/22 02:23 75-01-4 H1,H212/06/22 20:420.23 0.059 12.5 Xylene (Total)87.9 mg/kg 12/07/22 02:23 1330-20-712/06/22 20:420.23 0.066 12.5 m&p-Xylene 61.0 mg/kg 12/07/22 02:23 179601-23-1 H1,H212/06/22 20:420.23 0.080 12.5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:D-1 Lab ID:92638346001 Collected:11/21/22 11:45 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles o-Xylene 26.9 mg/kg 12/07/22 02:23 95-47-6 H1,H212/06/22 20:420.12 0.052 12.5 Surrogates Toluene-d8 (S)104 %12/07/22 02:23 2037-26-5 H312/06/22 20:4270-130 12.5 4-Bromofluorobenzene (S)103 %12/07/22 02:23 460-00-412/06/22 20:4270-130 12.5 1,2-Dichloroethane-d4 (S)127 %12/07/22 02:23 17060-07-012/06/22 20:4270-130 12.5 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 24.8 %11/28/22 17:55 N20.10 0.10 1 Analytical Method: SM 2540G Preparation Method: SM 2540 G Pace National - Mt. Juliet Total Solids 2540 G-2011 Total Solids 73.6 %12/12/22 14:3812/12/22 14:281 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:D-2 Lab ID:92638346002 Collected:11/21/22 12:25 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)265 mg/kg 11/25/22 16:2111/25/22 09:208.9 2.5 1 Surrogates 4-Bromofluorobenzene (S)112 %11/25/22 16:21 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 24.7 %11/28/22 17:55 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:D-3 Lab ID:92638346003 Collected:11/21/22 13:00 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)162 mg/kg 11/25/22 16:4611/25/22 09:2010.1 2.8 1 Surrogates 4-Bromofluorobenzene (S)179 %11/25/22 16:46 460-00-4 S511/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 23.8 %11/28/22 17:55 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:D-4 Lab ID:92638346004 Collected:11/21/22 13:20 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)ND mg/kg 12/01/22 12:2011/30/22 17:066.5 4.6 1 Surrogates n-Pentacosane (S)57 %12/01/22 12:20 629-99-211/30/22 17:0610-130 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)7.7J mg/kg 11/25/22 17:12 C811/25/22 09:209.6 2.6 1 Surrogates 4-Bromofluorobenzene (S)98 %11/25/22 17:12 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 23.0 %11/29/22 13:54 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:D-5 Lab ID:92638346005 Collected:11/21/22 14:00 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)6.5J mg/kg 12/01/22 12:3611/30/22 17:067.0 4.9 1 Surrogates n-Pentacosane (S)46 %12/01/22 12:36 629-99-211/30/22 17:0610-130 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)ND mg/kg 11/25/22 17:3811/25/22 09:2012.1 3.4 1 Surrogates 4-Bromofluorobenzene (S)95 %11/25/22 17:38 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 28.2 %11/29/22 13:54 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:D-6 Lab ID:92638346006 Collected:11/21/22 15:15 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)ND mg/kg 11/25/22 18:0411/25/22 09:209.4 2.6 1 Surrogates 4-Bromofluorobenzene (S)95 %11/25/22 18:04 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 22.6 %11/29/22 13:54 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 15 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:D-7 Lab ID:92638346007 Collected:11/21/22 15:30 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)ND mg/kg 12/01/22 12:3611/30/22 17:066.7 4.7 1 Surrogates n-Pentacosane (S)59 %12/01/22 12:36 629-99-211/30/22 17:0610-130 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)ND mg/kg 11/25/22 18:2911/25/22 09:209.6 2.7 1 Surrogates 4-Bromofluorobenzene (S)96 %11/25/22 18:29 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 25.2 %11/29/22 13:54 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 16 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-1 Lab ID:92638346008 Collected:11/21/22 17:30 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)4.1J mg/kg 11/25/22 18:5511/25/22 09:2010.5 2.9 1 Surrogates 4-Bromofluorobenzene (S)96 %11/25/22 18:55 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 22.7 %11/29/22 13:54 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 17 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-2 Lab ID:92638346009 Collected:11/21/22 21:00 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)3.5J mg/kg 11/25/22 19:2111/25/22 09:209.5 2.6 1 Surrogates 4-Bromofluorobenzene (S)95 %11/25/22 19:21 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 21.0 %11/29/22 13:54 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 18 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-3 Lab ID:92638346010 Collected:11/21/22 21:05 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)ND mg/kg 11/25/22 19:4611/25/22 09:208.7 2.4 1 Surrogates 4-Bromofluorobenzene (S)94 %11/25/22 19:46 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 23.0 %11/29/22 13:55 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 19 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-4 Lab ID:92638346011 Collected:11/21/22 21:10 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)ND mg/kg 11/25/22 20:1211/25/22 09:209.8 2.7 1 Surrogates 4-Bromofluorobenzene (S)95 %11/25/22 20:12 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 22.8 %11/29/22 13:55 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 20 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-5 Lab ID:92638346012 Collected:11/21/22 21:15 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)ND mg/kg 12/01/22 12:5311/30/22 17:066.5 4.6 1 Surrogates n-Pentacosane (S)63 %12/01/22 12:53 629-99-211/30/22 17:0610-130 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)7.0J mg/kg 11/25/22 20:3811/25/22 09:209.0 2.5 1 Surrogates 4-Bromofluorobenzene (S)95 %11/25/22 20:38 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 21.4 %11/29/22 13:55 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 21 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-6 Lab ID:92638346013 Collected:11/21/22 21:20 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)ND mg/kg 12/01/22 12:5311/30/22 17:066.3 4.5 1 Surrogates n-Pentacosane (S)61 %12/01/22 12:53 629-99-211/30/22 17:0610-130 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)3.9J mg/kg 11/25/22 21:04 C811/25/22 09:20102.8 1 Surrogates 4-Bromofluorobenzene (S)95 %11/25/22 21:04 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 19.5 %11/29/22 13:55 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 22 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-7 Lab ID:92638346014 Collected:11/21/22 21:25 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)16.2 mg/kg 12/01/22 13:0911/30/22 17:066.4 4.6 1 Surrogates n-Pentacosane (S)71 %12/01/22 13:09 629-99-211/30/22 17:0610-130 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)13.7 mg/kg 11/25/22 21:2911/25/22 09:2010.4 2.9 1 Surrogates 4-Bromofluorobenzene (S)110 %11/25/22 21:29 460-00-411/25/22 09:2066-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 21.4 %11/29/22 13:55 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 23 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-8 Lab ID:92638346015 Collected:11/21/22 17:30 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8015C Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8015 GCS THC-Diesel Diesel Range Organics(C10- C28)286 mg/kg 12/01/22 13:0911/30/22 17:066.9 4.9 1 Surrogates n-Pentacosane (S)63 %12/01/22 13:09 629-99-211/30/22 17:0610-130 1 Analytical Method: EPA 8015C Preparation Method: EPA 5030B Pace Analytical Services - Charlotte Gasoline Range Organics Gas Range Organics (C6-C10)1250 mg/kg 11/28/22 17:3311/28/22 11:2522.3 6.2 2 Surrogates 4-Bromofluorobenzene (S)144 %11/28/22 17:33 460-00-4 S211/28/22 11:2566-130 2 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 26.6 %11/29/22 13:55 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 24 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-8 (RISK)Lab ID:92638346016 Collected:11/21/22 17:30 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: MADEP EPH Preparation Method: MADEP EPH Pace Analytical Services - Charlotte MADEP EPH NC Soil Aliphatic (C09-C18)73.4 mg/kg 12/07/22 08:43 N212/05/22 17:2413.8 13.8 1 Aliphatic (C19-C36)ND mg/kg 12/07/22 08:43 N212/05/22 17:2413.8 13.8 1 Aromatic (C11-C22)66.0 mg/kg 12/07/22 08:43 N212/05/22 17:2413.8 13.8 1 Surrogates 1-Chlorooctadecane (S)79 %12/07/22 08:43 3386-33-212/05/22 17:2440-140 1 o-Terphenyl (S)82 %12/07/22 08:43 84-15-112/05/22 17:2440-140 1 2-Fluorobiphenyl (S)126 %12/07/22 08:43 321-60-812/05/22 17:2440-140 1 2-Bromonaphthalene (S)137 %12/07/22 08:43 580-13-212/05/22 17:2440-140 1 Analytical Method: MADEP VPH Preparation Method: MADEPV Pace National - Mt. Juliet MADEPV Aliphatic (C05-C08)125 mg/kg 12/13/22 10:3911/21/22 17:308.79 2.94 1 Aliphatic (C09-C12)369 mg/kg 12/13/22 10:3911/21/22 17:308.79 2.94 1 Aromatic (C09-C10),Unadjusted 323 mg/kg 12/17/22 15:42 TPHC9C10A11/21/22 17:3043.9 14.6 5 Total VPH 817 mg/kg 12/17/22 15:42 VPH11/21/22 17:3043.9 14.6 5 Surrogates 2,5-Dibromotoluene (FID)126 %12/13/22 10:39 615-59-8FID11/21/22 17:3070.0-130 1 2,5-Dibromotoluene (FID)107 %12/17/22 15:42 615-59-8FID11/21/22 17:3070.0-130 5 2,5-Dibromotoluene (PID)80.3 %12/13/22 10:39 615-59-8PID11/21/22 17:3070.0-130 1 2,5-Dibromotoluene (PID)87.3 %12/17/22 15:42 615-59-8PID11/21/22 17:3070.0-130 5 Analytical Method: EPA 8270E Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8270E MSSV Microwave Acenaphthene ND ug/kg 12/05/22 18:40 83-32-912/05/22 11:214541601 Acenaphthylene ND ug/kg 12/05/22 18:40 208-96-812/05/22 11:214541601 Aniline ND ug/kg 12/05/22 18:40 62-53-312/05/22 11:214541781 Anthracene ND ug/kg 12/05/22 18:40 120-12-712/05/22 11:214541491 Benzo(a)anthracene ND ug/kg 12/05/22 18:40 56-55-312/05/22 11:214541511 Benzo(a)pyrene ND ug/kg 12/05/22 18:40 50-32-812/05/22 11:214541571 Benzo(b)fluoranthene ND ug/kg 12/05/22 18:40 205-99-212/05/22 11:214541511 Benzo(g,h,i)perylene ND ug/kg 12/05/22 18:40 191-24-212/05/22 11:214541761 Benzo(k)fluoranthene ND ug/kg 12/05/22 18:40 207-08-912/05/22 11:214541601 Benzoic Acid ND ug/kg 12/05/22 18:40 65-85-012/05/22 11:2122709761 Benzyl alcohol ND ug/kg 12/05/22 18:40 100-51-612/05/22 11:219093441 4-Bromophenylphenyl ether ND ug/kg 12/05/22 18:40 101-55-312/05/22 11:214541751 Butylbenzylphthalate ND ug/kg 12/05/22 18:40 85-68-712/05/22 11:214541911 4-Chloro-3-methylphenol ND ug/kg 12/05/22 18:40 59-50-712/05/22 11:219093191 4-Chloroaniline ND ug/kg 12/05/22 18:40 106-47-812/05/22 11:219093571 bis(2-Chloroethoxy)methane ND ug/kg 12/05/22 18:40 111-91-112/05/22 11:214541891 bis(2-Chloroethyl) ether ND ug/kg 12/05/22 18:40 111-44-412/05/22 11:214541711 2-Chloronaphthalene ND ug/kg 12/05/22 18:40 91-58-712/05/22 11:214541801 2-Chlorophenol ND ug/kg 12/05/22 18:40 95-57-812/05/22 11:214541711 4-Chlorophenylphenyl ether ND ug/kg 12/05/22 18:40 7005-72-312/05/22 11:214541691 Chrysene ND ug/kg 12/05/22 18:40 218-01-912/05/22 11:214541651 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 25 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-8 (RISK)Lab ID:92638346016 Collected:11/21/22 17:30 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8270E Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8270E MSSV Microwave Dibenz(a,h)anthracene ND ug/kg 12/05/22 18:40 53-70-312/05/22 11:214541751 Dibenzofuran ND ug/kg 12/05/22 18:40 132-64-912/05/22 11:214541641 1,2-Dichlorobenzene ND ug/kg 12/05/22 18:40 95-50-112/05/22 11:214541641 1,3-Dichlorobenzene ND ug/kg 12/05/22 18:40 541-73-112/05/22 11:214541611 1,4-Dichlorobenzene ND ug/kg 12/05/22 18:40 106-46-712/05/22 11:214541731 3,3'-Dichlorobenzidine ND ug/kg 12/05/22 18:40 91-94-112/05/22 11:219093071 2,4-Dichlorophenol ND ug/kg 12/05/22 18:40 120-83-212/05/22 11:214541781 Diethylphthalate ND ug/kg 12/05/22 18:40 84-66-212/05/22 11:214541671 2,4-Dimethylphenol ND ug/kg 12/05/22 18:40 105-67-912/05/22 11:214541891 Dimethylphthalate ND ug/kg 12/05/22 18:40 131-11-312/05/22 11:214541651 Di-n-butylphthalate ND ug/kg 12/05/22 18:40 84-74-212/05/22 11:214541531 4,6-Dinitro-2-methylphenol ND ug/kg 12/05/22 18:40 534-52-112/05/22 11:219094241 2,4-Dinitrophenol ND ug/kg 12/05/22 18:40 51-28-512/05/22 11:21227014001 2,4-Dinitrotoluene ND ug/kg 12/05/22 18:40 121-14-212/05/22 11:214541751 2,6-Dinitrotoluene ND ug/kg 12/05/22 18:40 606-20-212/05/22 11:214541671 Di-n-octylphthalate ND ug/kg 12/05/22 18:40 117-84-012/05/22 11:214541791 bis(2-Ethylhexyl)phthalate ND ug/kg 12/05/22 18:40 117-81-712/05/22 11:214541761 Fluoranthene ND ug/kg 12/05/22 18:40 206-44-012/05/22 11:214541561 Fluorene ND ug/kg 12/05/22 18:40 86-73-712/05/22 11:214541601 Hexachloro-1,3-butadiene ND ug/kg 12/05/22 18:40 87-68-312/05/22 11:214541971 Hexachlorobenzene ND ug/kg 12/05/22 18:40 118-74-112/05/22 11:214541781 Hexachlorocyclopentadiene ND ug/kg 12/05/22 18:40 77-47-412/05/22 11:214542601 Hexachloroethane ND ug/kg 12/05/22 18:40 67-72-112/05/22 11:214541731 Indeno(1,2,3-cd)pyrene ND ug/kg 12/05/22 18:40 193-39-512/05/22 11:214541791 Isophorone ND ug/kg 12/05/22 18:40 78-59-112/05/22 11:214542021 1-Methylnaphthalene 3360 ug/kg 12/05/22 18:40 90-12-012/05/22 11:214541601 2-Methylnaphthalene 7150 ug/kg 12/06/22 09:18 91-57-612/05/22 11:219093632 2-Methylphenol(o-Cresol)ND ug/kg 12/05/22 18:40 95-48-712/05/22 11:214541861 3&4-Methylphenol(m&p Cresol)ND ug/kg 12/05/22 18:40 15831-10-412/05/22 11:214541831 Naphthalene 4480 ug/kg 12/06/22 09:18 91-20-312/05/22 11:219093082 2-Nitroaniline ND ug/kg 12/05/22 18:40 88-74-412/05/22 11:2122703721 3-Nitroaniline ND ug/kg 12/05/22 18:40 99-09-212/05/22 11:2122703571 4-Nitroaniline ND ug/kg 12/05/22 18:40 100-01-612/05/22 11:219093461 Nitrobenzene ND ug/kg 12/05/22 18:40 98-95-312/05/22 11:214542111 2-Nitrophenol ND ug/kg 12/05/22 18:40 88-75-512/05/22 11:214541971 4-Nitrophenol ND ug/kg 12/05/22 18:40 100-02-712/05/22 11:2122708781 N-Nitrosodimethylamine ND ug/kg 12/05/22 18:40 62-75-912/05/22 11:214541531 N-Nitroso-di-n-propylamine ND ug/kg 12/05/22 18:40 621-64-712/05/22 11:214541711 N-Nitrosodiphenylamine ND ug/kg 12/05/22 18:40 86-30-612/05/22 11:214541611 2,2'-Oxybis(1-chloropropane)ND ug/kg 12/05/22 18:40 108-60-112/05/22 11:214542161 Pentachlorophenol ND ug/kg 12/05/22 18:40 87-86-512/05/22 11:219094451 Phenanthrene ND ug/kg 12/05/22 18:40 85-01-812/05/22 11:214541491 Phenol ND ug/kg 12/05/22 18:40 108-95-212/05/22 11:214542021 Pyrene ND ug/kg 12/05/22 18:40 129-00-012/05/22 11:214541841 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 26 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-8 (RISK)Lab ID:92638346016 Collected:11/21/22 17:30 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8270E Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8270E MSSV Microwave Pyridine ND ug/kg 12/05/22 18:40 110-86-112/05/22 11:214541431 1,2,4-Trichlorobenzene ND ug/kg 12/05/22 18:40 120-82-112/05/22 11:214541791 2,4,5-Trichlorophenol ND ug/kg 12/05/22 18:40 95-95-412/05/22 11:214542081 2,4,6-Trichlorophenol ND ug/kg 12/05/22 18:40 88-06-212/05/22 11:214541871 Surrogates Nitrobenzene-d5 (S)72 %12/05/22 18:40 4165-60-012/05/22 11:2110-130 1 2-Fluorobiphenyl (S)65 %12/05/22 18:40 321-60-812/05/22 11:2110-130 1 Terphenyl-d14 (S)82 %12/05/22 18:40 1718-51-012/05/22 11:2110-130 1 Phenol-d6 (S)70 %12/05/22 18:40 13127-88-312/05/22 11:2110-130 1 2-Fluorophenol (S)70 %12/05/22 18:40 367-12-412/05/22 11:2110-130 1 2,4,6-Tribromophenol (S)84 %12/05/22 18:40 118-79-612/05/22 11:2110-131 1 Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles Acetone 0.57J mg/kg 12/05/22 17:15 67-64-112/05/22 15:441.6 0.53 10 Benzene ND mg/kg 12/05/22 17:15 71-43-212/05/22 15:440.082 0.033 10 Bromobenzene ND mg/kg 12/05/22 17:15 108-86-112/05/22 15:440.082 0.027 10 Bromochloromethane ND mg/kg 12/05/22 17:15 74-97-512/05/22 15:440.082 0.024 10 Bromodichloromethane ND mg/kg 12/05/22 17:15 75-27-412/05/22 15:440.082 0.032 10 Bromoform ND mg/kg 12/05/22 17:15 75-25-212/05/22 15:440.082 0.029 10 Bromomethane ND mg/kg 12/05/22 17:15 74-83-912/05/22 15:440.16 0.13 10 2-Butanone (MEK)ND mg/kg 12/05/22 17:15 78-93-312/05/22 15:441.6 0.39 10 n-Butylbenzene 3.3 mg/kg 12/05/22 17:15 104-51-812/05/22 15:440.082 0.039 10 sec-Butylbenzene ND mg/kg 12/05/22 17:15 135-98-812/05/22 15:440.082 0.036 10 tert-Butylbenzene ND mg/kg 12/05/22 17:15 98-06-612/05/22 15:440.082 0.029 10 Carbon tetrachloride ND mg/kg 12/05/22 17:15 56-23-512/05/22 15:440.082 0.031 10 Chlorobenzene 0.15 mg/kg 12/05/22 17:15 108-90-712/05/22 15:440.082 0.016 10 Chloroethane ND mg/kg 12/05/22 17:15 75-00-312/05/22 15:440.16 0.063 10 Chloroform ND mg/kg 12/05/22 17:15 67-66-312/05/22 15:440.082 0.050 10 Chloromethane ND mg/kg 12/05/22 17:15 74-87-312/05/22 15:440.16 0.069 10 2-Chlorotoluene ND mg/kg 12/05/22 17:15 95-49-812/05/22 15:440.082 0.029 10 4-Chlorotoluene ND mg/kg 12/05/22 17:15 106-43-412/05/22 15:440.082 0.014 10 1,2-Dibromo-3-chloropropane ND mg/kg 12/05/22 17:15 96-12-812/05/22 15:440.082 0.032 10 Dibromochloromethane ND mg/kg 12/05/22 17:15 124-48-112/05/22 15:440.082 0.046 10 1,2-Dibromoethane (EDB)ND mg/kg 12/05/22 17:15 106-93-412/05/22 15:440.082 0.036 10 Dibromomethane ND mg/kg 12/05/22 17:15 74-95-312/05/22 15:440.082 0.018 10 1,2-Dichlorobenzene ND mg/kg 12/05/22 17:15 95-50-112/05/22 15:440.082 0.029 10 1,3-Dichlorobenzene ND mg/kg 12/05/22 17:15 541-73-112/05/22 15:440.082 0.025 10 1,4-Dichlorobenzene ND mg/kg 12/05/22 17:15 106-46-712/05/22 15:440.082 0.021 10 Dichlorodifluoromethane ND mg/kg 12/05/22 17:15 75-71-812/05/22 15:440.16 0.036 10 1,1-Dichloroethane ND mg/kg 12/05/22 17:15 75-34-312/05/22 15:440.082 0.034 10 1,2-Dichloroethane ND mg/kg 12/05/22 17:15 107-06-212/05/22 15:440.082 0.054 10 1,1-Dichloroethene ND mg/kg 12/05/22 17:15 75-35-412/05/22 15:440.082 0.034 10 cis-1,2-Dichloroethene ND mg/kg 12/05/22 17:15 156-59-212/05/22 15:440.082 0.028 10 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 27 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-8 (RISK)Lab ID:92638346016 Collected:11/21/22 17:30 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles trans-1,2-Dichloroethene ND mg/kg 12/05/22 17:15 156-60-512/05/22 15:440.082 0.029 10 1,2-Dichloropropane ND mg/kg 12/05/22 17:15 78-87-512/05/22 15:440.082 0.025 10 1,3-Dichloropropane ND mg/kg 12/05/22 17:15 142-28-912/05/22 15:440.082 0.026 10 2,2-Dichloropropane ND mg/kg 12/05/22 17:15 594-20-712/05/22 15:440.082 0.027 10 1,1-Dichloropropene ND mg/kg 12/05/22 17:15 563-58-612/05/22 15:440.082 0.039 10 cis-1,3-Dichloropropene ND mg/kg 12/05/22 17:15 10061-01-512/05/22 15:440.082 0.022 10 trans-1,3-Dichloropropene ND mg/kg 12/05/22 17:15 10061-02-612/05/22 15:440.082 0.028 10 Diisopropyl ether ND mg/kg 12/05/22 17:15 108-20-312/05/22 15:440.082 0.022 10 Ethylbenzene 3.6 mg/kg 12/05/22 17:15 100-41-412/05/22 15:440.082 0.038 10 Hexachloro-1,3-butadiene ND mg/kg 12/05/22 17:15 87-68-312/05/22 15:440.16 0.13 10 2-Hexanone ND mg/kg 12/05/22 17:15 591-78-612/05/22 15:440.82 0.079 10 Isopropylbenzene (Cumene)1.4 mg/kg 12/05/22 17:15 98-82-812/05/22 15:440.082 0.028 10 p-Isopropyltoluene ND mg/kg 12/05/22 17:15 99-87-612/05/22 15:440.082 0.040 10 Methylene Chloride ND mg/kg 12/05/22 17:15 75-09-212/05/22 15:440.33 0.22 10 4-Methyl-2-pentanone (MIBK)ND mg/kg 12/05/22 17:15 108-10-112/05/22 15:440.82 0.079 10 Methyl-tert-butyl ether ND mg/kg 12/05/22 17:15 1634-04-412/05/22 15:440.082 0.031 10 Naphthalene 9.9 mg/kg 12/05/22 17:15 91-20-312/05/22 15:440.082 0.043 10 n-Propylbenzene 6.0 mg/kg 12/05/22 17:15 103-65-112/05/22 15:440.082 0.029 10 Styrene ND mg/kg 12/05/22 17:15 100-42-512/05/22 15:440.082 0.022 10 1,1,1,2-Tetrachloroethane ND mg/kg 12/05/22 17:15 630-20-612/05/22 15:440.082 0.031 10 1,1,2,2-Tetrachloroethane ND mg/kg 12/05/22 17:15 79-34-512/05/22 15:440.082 0.022 10 Tetrachloroethene ND mg/kg 12/05/22 17:15 127-18-412/05/22 15:440.082 0.026 10 Toluene 0.12 mg/kg 12/05/22 17:15 108-88-312/05/22 15:440.082 0.023 10 1,2,3-Trichlorobenzene ND mg/kg 12/05/22 17:15 87-61-612/05/22 15:440.082 0.066 10 1,2,4-Trichlorobenzene ND mg/kg 12/05/22 17:15 120-82-112/05/22 15:440.082 0.069 10 1,1,1-Trichloroethane ND mg/kg 12/05/22 17:15 71-55-612/05/22 15:440.082 0.043 10 1,1,2-Trichloroethane ND mg/kg 12/05/22 17:15 79-00-512/05/22 15:440.082 0.027 10 Trichloroethene ND mg/kg 12/05/22 17:15 79-01-612/05/22 15:440.082 0.021 10 Trichlorofluoromethane ND mg/kg 12/05/22 17:15 75-69-412/05/22 15:440.082 0.045 10 1,2,3-Trichloropropane ND mg/kg 12/05/22 17:15 96-18-412/05/22 15:440.082 0.041 10 1,2,4-Trimethylbenzene 38.0 mg/kg 12/05/22 17:15 95-63-612/05/22 15:440.082 0.022 10 1,3,5-Trimethylbenzene 8.1 mg/kg 12/05/22 17:15 108-67-812/05/22 15:440.082 0.028 10 Vinyl acetate ND mg/kg 12/05/22 17:15 108-05-412/05/22 15:440.82 0.060 10 Vinyl chloride ND mg/kg 12/05/22 17:15 75-01-412/05/22 15:440.16 0.042 10 Xylene (Total)5.2 mg/kg 12/05/22 17:15 1330-20-712/05/22 15:440.16 0.047 10 m&p-Xylene 4.4 mg/kg 12/05/22 17:15 179601-23-112/05/22 15:440.16 0.056 10 o-Xylene 0.83 mg/kg 12/05/22 17:15 95-47-612/05/22 15:440.082 0.036 10 Surrogates Toluene-d8 (S)104 %12/05/22 17:15 2037-26-512/05/22 15:4470-130 10 4-Bromofluorobenzene (S)105 %12/05/22 17:15 460-00-412/05/22 15:4470-130 10 1,2-Dichloroethane-d4 (S)101 %12/05/22 17:15 17060-07-012/05/22 15:4470-130 10 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 28 of 69 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Sample:PL-8 (RISK)Lab ID:92638346016 Collected:11/21/22 17:30 Received:11/22/22 11:55 Matrix:Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No.QualMDLLimit Report Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 26.9 %12/08/22 13:49 N20.10 0.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 29 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 1973216 KS LRH/MADEPV/MTDEQ VPH/VPH MADEP VPH MADEPV Laboratory:Pace National - Mt. Juliet Associated Lab Samples:92638346001, 92638346016 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3871296-3 Associated Lab Samples:92638346001, 92638346016 Matrix:Solid AnalyzedMDL Aliphatic (C05-C08)mg/kg ND 5.00 12/13/22 04:391.67 Aliphatic (C09-C12)mg/kg ND 5.00 12/13/22 04:391.67 2,5-Dibromotoluene (FID)%104 70.0-130 12/13/22 04:39 2,5-Dibromotoluene (PID)%103 70.0-130 12/13/22 04:39 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3871296-1LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result R3871296-2 Aliphatic (C05-C08)mg/kg 53.060.0 88.3 70.0-13090.054.0 1.87 25 Aliphatic (C09-C12)mg/kg 62.670.0 89.4 70.0-13096.967.8 7.98 25 2,5-Dibromotoluene (FID)%104 70.0-130105 2,5-Dibromotoluene (PID)%104 70.0-130103 Parameter Units MS Result % Rec Limits Qual% RecConc. R3871296-4MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result L1565820-01 R3871296-5 MSD Result MSD % Rec RPD RPD Max MSDMS Spike Conc. Aliphatic (C05-C08)mg/kg 79.9 101 70.0-130107 5.07 2579.9ND 81.0 85.2 Aliphatic (C09-C12)mg/kg 93.2 104 70.0-130101 3.35 2593.2ND 97.0 93.8 2,5-Dibromotoluene (FID)%97.9 70.0-13097.0 2,5-Dibromotoluene (PID)%92.7 70.0-13094.2 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 30 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 1973747 KS LRH/MADEPV/MTDEQ VPH/VPH MADEP VPH MADEPV Laboratory:Pace National - Mt. Juliet Associated Lab Samples:92638346001, 92638346016 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3873257-3 Associated Lab Samples:92638346001, 92638346016 Matrix:Solid AnalyzedMDL Aromatic (C09-C10),Unadjusted mg/kg ND 5.00 12/17/22 13:361.67 Total VPH mg/kg ND 5.00 12/17/22 13:361.67 2,5-Dibromotoluene (FID)%91.9 70.0-130 12/17/22 13:36 2,5-Dibromotoluene (PID)%81.2 70.0-130 12/17/22 13:36 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3873257-1LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result R3873257-2 Aromatic (C09-C10),Unadjusted mg/kg 9.7010.0 97.0 70.0-13094.99.49 2.19 25 Total VPH mg/kg 122140 87.1 70.0-13084.3118 3.33 25 2,5-Dibromotoluene (FID)%98.4 70.0-13092.1 2,5-Dibromotoluene (PID)%88.3 70.0-13083.4 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 31 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 739300 EPA 5030B EPA 8015C Gasoline Range Organics Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92638346002, 92638346003, 92638346004, 92638346005, 92638346006, 92638346007, 92638346008, 92638346009, 92638346010, 92638346011, 92638346012, 92638346013, 92638346014 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3847203 Associated Lab Samples:92638346002, 92638346003, 92638346004, 92638346005, 92638346006, 92638346007, 92638346008, 92638346009, 92638346010, 92638346011, 92638346012, 92638346013, 92638346014 Matrix:Solid AnalyzedMDL Gas Range Organics (C6-C10)mg/kg ND 6.0 11/25/22 12:551.7 4-Bromofluorobenzene (S)%94 66-130 11/25/22 12:55 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3847204LABORATORY CONTROL SAMPLE: LCSSpike Gas Range Organics (C6-C10)mg/kg 53.949.8 108 70-130 4-Bromofluorobenzene (S)%97 66-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3847206MATRIX SPIKE SAMPLE: MSSpike Result 92637874006 Gas Range Organics (C6-C10)mg/kg 74.470.5 105 65-146ND 4-Bromofluorobenzene (S)%99 66-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92638336001 3847205SAMPLE DUPLICATE: Gas Range Organics (C6-C10)mg/kg ND 30ND 4-Bromofluorobenzene (S)%9696 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 32 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 739499 EPA 5030B EPA 8015C Gasoline Range Organics Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92638346001, 92638346015 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3847788 Associated Lab Samples:92638346001, 92638346015 Matrix:Solid AnalyzedMDL Gas Range Organics (C6-C10)mg/kg ND 6.0 11/28/22 14:071.7 4-Bromofluorobenzene (S)%97 66-130 11/28/22 14:07 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3847789LABORATORY CONTROL SAMPLE: LCSSpike Gas Range Organics (C6-C10)mg/kg 59.150.1 118 70-130 4-Bromofluorobenzene (S)%99 66-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3847791MATRIX SPIKE SAMPLE: MSSpike Result 92638196004 Gas Range Organics (C6-C10)mg/kg 21979.5 109 65-146132 4-Bromofluorobenzene (S)%102 66-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92637816033 3847790SAMPLE DUPLICATE: Gas Range Organics (C6-C10)mg/kg ND 30ND 4-Bromofluorobenzene (S)%10098 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 33 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 741169 EPA 5035A/5030B EPA 8260D 8260D 5035A 5030B Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92638346016 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3855708 Associated Lab Samples:92638346016 Matrix:Solid AnalyzedMDL 1,1,1,2-Tetrachloroethane mg/kg ND 0.0050 12/05/22 16:200.0019 1,1,1-Trichloroethane mg/kg ND 0.0050 12/05/22 16:200.0026 1,1,2,2-Tetrachloroethane mg/kg ND 0.0050 12/05/22 16:200.0013 1,1,2-Trichloroethane mg/kg ND 0.0050 12/05/22 16:200.0017 1,1-Dichloroethane mg/kg ND 0.0050 12/05/22 16:200.0021 1,1-Dichloroethene mg/kg ND 0.0050 12/05/22 16:200.0021 1,1-Dichloropropene mg/kg ND 0.0050 12/05/22 16:200.0024 1,2,3-Trichlorobenzene mg/kg ND 0.0050 12/05/22 16:200.0040 1,2,3-Trichloropropane mg/kg ND 0.0050 12/05/22 16:200.0025 1,2,4-Trichlorobenzene mg/kg ND 0.0050 12/05/22 16:200.0042 1,2,4-Trimethylbenzene mg/kg ND 0.0050 12/05/22 16:200.0014 1,2-Dibromo-3-chloropropane mg/kg ND 0.0050 12/05/22 16:200.0019 1,2-Dibromoethane (EDB)mg/kg ND 0.0050 12/05/22 16:200.0022 1,2-Dichlorobenzene mg/kg ND 0.0050 12/05/22 16:200.0018 1,2-Dichloroethane mg/kg ND 0.0050 12/05/22 16:200.0033 1,2-Dichloropropane mg/kg ND 0.0050 12/05/22 16:200.0015 1,3,5-Trimethylbenzene mg/kg ND 0.0050 12/05/22 16:200.0017 1,3-Dichlorobenzene mg/kg ND 0.0050 12/05/22 16:200.0016 1,3-Dichloropropane mg/kg ND 0.0050 12/05/22 16:200.0016 1,4-Dichlorobenzene mg/kg ND 0.0050 12/05/22 16:200.0013 2,2-Dichloropropane mg/kg ND 0.0050 12/05/22 16:200.0016 2-Butanone (MEK)mg/kg ND 0.10 12/05/22 16:200.024 2-Chlorotoluene mg/kg ND 0.0050 12/05/22 16:200.0018 2-Hexanone mg/kg ND 0.050 12/05/22 16:200.0048 4-Chlorotoluene mg/kg ND 0.0050 12/05/22 16:200.00088 4-Methyl-2-pentanone (MIBK)mg/kg ND 0.050 12/05/22 16:200.0048 Acetone mg/kg ND 0.10 12/05/22 16:200.032 Benzene mg/kg ND 0.0050 12/05/22 16:200.0020 Bromobenzene mg/kg ND 0.0050 12/05/22 16:200.0016 Bromochloromethane mg/kg ND 0.0050 12/05/22 16:200.0015 Bromodichloromethane mg/kg ND 0.0050 12/05/22 16:200.0019 Bromoform mg/kg ND 0.0050 12/05/22 16:200.0018 Bromomethane mg/kg ND 0.010 12/05/22 16:200.0079 Carbon tetrachloride mg/kg ND 0.0050 12/05/22 16:200.0019 Chlorobenzene mg/kg ND 0.0050 12/05/22 16:200.00096 Chloroethane mg/kg ND 0.010 12/05/22 16:200.0039 Chloroform mg/kg ND 0.0050 12/05/22 16:200.0030 Chloromethane mg/kg ND 0.010 12/05/22 16:200.0042 cis-1,2-Dichloroethene mg/kg ND 0.0050 12/05/22 16:200.0017 cis-1,3-Dichloropropene mg/kg ND 0.0050 12/05/22 16:200.0014 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 34 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3855708 Associated Lab Samples:92638346016 Matrix:Solid AnalyzedMDL Dibromochloromethane mg/kg ND 0.0050 12/05/22 16:200.0028 Dibromomethane mg/kg ND 0.0050 12/05/22 16:200.0011 Dichlorodifluoromethane mg/kg ND 0.010 12/05/22 16:200.0022 Diisopropyl ether mg/kg ND 0.0050 12/05/22 16:200.0014 Ethylbenzene mg/kg ND 0.0050 12/05/22 16:200.0023 Hexachloro-1,3-butadiene mg/kg ND 0.010 12/05/22 16:200.0082 Isopropylbenzene (Cumene)mg/kg ND 0.0050 12/05/22 16:200.0017 m&p-Xylene mg/kg ND 0.010 12/05/22 16:200.0034 Methyl-tert-butyl ether mg/kg ND 0.0050 12/05/22 16:200.0019 Methylene Chloride mg/kg ND 0.020 12/05/22 16:200.014 n-Butylbenzene mg/kg ND 0.0050 12/05/22 16:200.0024 n-Propylbenzene mg/kg ND 0.0050 12/05/22 16:200.0018 Naphthalene mg/kg ND 0.0050 12/05/22 16:200.0026 o-Xylene mg/kg ND 0.0050 12/05/22 16:200.0022 p-Isopropyltoluene mg/kg ND 0.0050 12/05/22 16:200.0025 sec-Butylbenzene mg/kg ND 0.0050 12/05/22 16:200.0022 Styrene mg/kg ND 0.0050 12/05/22 16:200.0013 tert-Butylbenzene mg/kg ND 0.0050 12/05/22 16:200.0018 Tetrachloroethene mg/kg ND 0.0050 12/05/22 16:200.0016 Toluene mg/kg ND 0.0050 12/05/22 16:200.0014 trans-1,2-Dichloroethene mg/kg ND 0.0050 12/05/22 16:200.0018 trans-1,3-Dichloropropene mg/kg ND 0.0050 12/05/22 16:200.0017 Trichloroethene mg/kg ND 0.0050 12/05/22 16:200.0013 Trichlorofluoromethane mg/kg ND 0.0050 12/05/22 16:200.0028 Vinyl acetate mg/kg ND 0.050 12/05/22 16:200.0036 Vinyl chloride mg/kg ND 0.010 12/05/22 16:200.0025 Xylene (Total)mg/kg ND 0.010 12/05/22 16:200.0028 1,2-Dichloroethane-d4 (S)%106 70-130 12/05/22 16:20 4-Bromofluorobenzene (S)%100 70-130 12/05/22 16:20 Toluene-d8 (S)%100 70-130 12/05/22 16:20 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3855709LABORATORY CONTROL SAMPLE: LCSSpike 1,1,1,2-Tetrachloroethane mg/kg 1.21.2 93 70-130 1,1,1-Trichloroethane mg/kg 1.21.2 92 70-130 1,1,2,2-Tetrachloroethane mg/kg 1.21.2 98 70-130 1,1,2-Trichloroethane mg/kg 1.21.2 94 70-130 1,1-Dichloroethane mg/kg 1.11.2 89 70-130 1,1-Dichloroethene mg/kg 1.21.2 96 70-130 1,1-Dichloropropene mg/kg 1.31.2 102 70-130 1,2,3-Trichlorobenzene mg/kg 1.41.2 112 70-130 1,2,3-Trichloropropane mg/kg 1.31.2 104 70-130 1,2,4-Trichlorobenzene mg/kg 1.31.2 101 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 35 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3855709LABORATORY CONTROL SAMPLE: LCSSpike 1,2,4-Trimethylbenzene mg/kg 1.21.2 95 70-130 1,2-Dibromo-3-chloropropane mg/kg 1.31.2 104 67-130 1,2-Dibromoethane (EDB)mg/kg 1.21.2 97 70-130 1,2-Dichlorobenzene mg/kg 1.21.2 93 70-130 1,2-Dichloroethane mg/kg 1.11.2 92 70-130 1,2-Dichloropropane mg/kg 1.21.2 95 70-130 1,3,5-Trimethylbenzene mg/kg 1.21.2 95 70-130 1,3-Dichlorobenzene mg/kg 1.21.2 97 70-130 1,3-Dichloropropane mg/kg 1.21.2 94 70-130 1,4-Dichlorobenzene mg/kg 1.11.2 91 70-130 2,2-Dichloropropane mg/kg 1.21.2 92 67-130 2-Butanone (MEK)mg/kg 2.52.5 100 66-130 2-Chlorotoluene mg/kg 1.21.2 95 70-130 2-Hexanone mg/kg 2.62.5 106 70-130 4-Chlorotoluene mg/kg 1.21.2 93 70-130 4-Methyl-2-pentanone (MIBK)mg/kg 2.52.5 99 70-130 Acetone mg/kg 2.32.5 92 67-130 Benzene mg/kg 1.11.2 87 70-130 Bromobenzene mg/kg 1.11.2 92 70-130 Bromochloromethane mg/kg 1.11.2 90 70-130 Bromodichloromethane mg/kg 1.21.2 92 70-130 Bromoform mg/kg 1.21.2 99 70-130 Bromomethane mg/kg 1.21.2 100 53-175 Carbon tetrachloride mg/kg 1.21.2 95 70-130 Chlorobenzene mg/kg 1.21.2 95 70-130 Chloroethane mg/kg 1.21.2 99 70-135 Chloroform mg/kg 1.21.2 92 70-130 Chloromethane mg/kg 1.21.2 98 64-130 cis-1,2-Dichloroethene mg/kg 1.21.2 93 70-130 cis-1,3-Dichloropropene mg/kg 1.21.2 95 70-130 Dibromochloromethane mg/kg 1.21.2 96 70-130 Dibromomethane mg/kg 1.11.2 91 70-130 Dichlorodifluoromethane mg/kg 1.11.2 91 63-145 Diisopropyl ether mg/kg 1.21.2 95 68-130 Ethylbenzene mg/kg 1.11.2 89 70-130 Hexachloro-1,3-butadiene mg/kg 1.21.2 95 70-130 Isopropylbenzene (Cumene)mg/kg 1.21.2 99 70-130 m&p-Xylene mg/kg 2.42.5 97 70-130 Methyl-tert-butyl ether mg/kg 1.21.2 93 70-130 Methylene Chloride mg/kg 1.11.2 91 67-130 n-Butylbenzene mg/kg 1.21.2 96 70-130 n-Propylbenzene mg/kg 1.21.2 92 70-130 Naphthalene mg/kg 1.41.2 108 70-130 o-Xylene mg/kg 1.21.2 97 70-130 p-Isopropyltoluene mg/kg 1.21.2 99 70-130 sec-Butylbenzene mg/kg 1.21.2 95 70-130 Styrene mg/kg 1.31.2 101 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 36 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3855709LABORATORY CONTROL SAMPLE: LCSSpike tert-Butylbenzene mg/kg 1.21.2 94 64-130 Tetrachloroethene mg/kg 1.21.2 93 70-130 Toluene mg/kg 1.11.2 89 70-130 trans-1,2-Dichloroethene mg/kg 1.21.2 93 70-130 trans-1,3-Dichloropropene mg/kg 1.21.2 95 70-130 Trichloroethene mg/kg 1.21.2 95 70-130 Trichlorofluoromethane mg/kg 1.21.2 92 70-130 Vinyl acetate mg/kg 2.72.5 109 70-134 Vinyl chloride mg/kg 1.21.2 100 68-130 Xylene (Total)mg/kg 3.63.8 97 70-130 1,2-Dichloroethane-d4 (S)%94 70-130 4-Bromofluorobenzene (S)%104 70-130 Toluene-d8 (S)%98 70-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3855710MATRIX SPIKE SAMPLE: MSSpike Result 92639512001 1,1,1,2-Tetrachloroethane mg/kg 0.920.91 102 58-140ND 1,1,1-Trichloroethane mg/kg 1.00.91 113 58-144ND 1,1,2,2-Tetrachloroethane mg/kg 0.930.91 103 52-139ND 1,1,2-Trichloroethane mg/kg 0.940.91 104 56-140ND 1,1-Dichloroethane mg/kg 0.930.91 104 58-145ND 1,1-Dichloroethene mg/kg 1.00.91 116 57-158ND 1,1-Dichloropropene mg/kg 1.10.91 121 58-151ND 1,2,3-Trichlorobenzene mg/kg 0.38 M10.91 42 48-149ND 1,2,3-Trichloropropane mg/kg 0.960.91 107 54-132ND 1,2,4-Trichlorobenzene mg/kg 0.660.91 73 51-151ND 1,2,4-Trimethylbenzene mg/kg 0.900.91 99 38-170ND 1,2-Dibromo-3-chloropropane mg/kg 0.770.91 85 44-134ND 1,2-Dibromoethane (EDB)mg/kg 0.920.91 102 60-138ND 1,2-Dichlorobenzene mg/kg 0.890.91 98 59-147ND 1,2-Dichloroethane mg/kg 0.940.91 105 57-139ND 1,2-Dichloropropane mg/kg 0.930.91 103 62-145ND 1,3,5-Trimethylbenzene mg/kg 0.920.91 102 47-159ND 1,3-Dichlorobenzene mg/kg 0.890.91 99 58-144ND 1,3-Dichloropropane mg/kg 0.900.91 100 60-142ND 1,4-Dichlorobenzene mg/kg 0.890.91 98 57-143ND 2,2-Dichloropropane mg/kg 0.890.91 99 37-144ND 2-Butanone (MEK)mg/kg 1.81.9 101 28-146ND 2-Chlorotoluene mg/kg 0.940.91 105 55-158ND 2-Hexanone mg/kg 1.81.9 98 44-141ND 4-Chlorotoluene mg/kg 0.890.91 98 55-146ND 4-Methyl-2-pentanone (MIBK)mg/kg 1.91.9 103 50-138ND Acetone mg/kg 1.61.9 89 20-136ND Benzene mg/kg 0.890.91 98 60-145ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 37 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3855710MATRIX SPIKE SAMPLE: MSSpike Result 92639512001 Bromobenzene mg/kg 0.870.91 96 59-145ND Bromochloromethane mg/kg 0.910.91 100 57-143ND Bromodichloromethane mg/kg 0.950.91 105 53-133ND Bromoform mg/kg 0.930.91 103 48-133ND Bromomethane mg/kg 0.900.91 99 10-167ND Carbon tetrachloride mg/kg 0.970.91 108 57-147ND Chlorobenzene mg/kg 0.950.91 105 61-144ND Chloroethane mg/kg 0.680.91 75 10-153ND Chloroform mg/kg 0.970.91 107 58-141ND Chloromethane mg/kg 1.10.91 120 54-165ND cis-1,2-Dichloroethene mg/kg 0.970.91 107 59-144ND cis-1,3-Dichloropropene mg/kg 0.950.91 105 56-137ND Dibromochloromethane mg/kg 0.910.91 101 53-139ND Dibromomethane mg/kg 0.860.91 96 60-136ND Dichlorodifluoromethane mg/kg 1.00.91 112 49-177ND Diisopropyl ether mg/kg 0.980.91 108 53-136ND Ethylbenzene mg/kg 0.880.91 98 53-150ND Hexachloro-1,3-butadiene mg/kg 0.820.91 91 42-186ND Isopropylbenzene (Cumene)mg/kg 0.970.91 108 62-154ND m&p-Xylene mg/kg 1.91.9 105 49-156ND Methyl-tert-butyl ether mg/kg 0.920.91 102 54-133ND Methylene Chloride mg/kg 0.960.91 107 50-153ND n-Butylbenzene mg/kg 0.920.91 102 44-174ND n-Propylbenzene mg/kg 0.910.91 101 52-157ND Naphthalene mg/kg 0.430.91 48 37-150ND o-Xylene mg/kg 0.960.91 106 54-150ND p-Isopropyltoluene mg/kg 0.940.91 105 50-164ND sec-Butylbenzene mg/kg 0.950.91 105 58-161ND Styrene mg/kg 0.980.91 108 60-148ND tert-Butylbenzene mg/kg 0.890.91 99 44-151ND Tetrachloroethene mg/kg 0.860.91 96 53-151ND Toluene mg/kg 0.920.91 102 52-148ND trans-1,2-Dichloroethene mg/kg 0.980.91 108 60-148ND trans-1,3-Dichloropropene mg/kg 0.930.91 103 55-133ND Trichloroethene mg/kg 0.950.91 105 60-148ND Trichlorofluoromethane mg/kg 0.880.91 98 10-154ND Vinyl acetate mg/kg 1.81.9 98 50-149ND Vinyl chloride mg/kg 1.10.91 117 57-157ND Xylene (Total)mg/kg 2.82.7 105 52-153ND 1,2-Dichloroethane-d4 (S)%104 70-130 4-Bromofluorobenzene (S)%107 70-130 Toluene-d8 (S)%101 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 38 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92639512002 3855711SAMPLE DUPLICATE: 1,1,1,2-Tetrachloroethane mg/kg ND 30ND 1,1,1-Trichloroethane mg/kg ND 30ND 1,1,2,2-Tetrachloroethane mg/kg ND 30ND 1,1,2-Trichloroethane mg/kg ND 30ND 1,1-Dichloroethane mg/kg ND 30ND 1,1-Dichloroethene mg/kg ND 30ND 1,1-Dichloropropene mg/kg ND 30ND 1,2,3-Trichlorobenzene mg/kg ND 30ND 1,2,3-Trichloropropane mg/kg ND 30ND 1,2,4-Trichlorobenzene mg/kg ND 30ND 1,2,4-Trimethylbenzene mg/kg ND 30ND 1,2-Dibromo-3-chloropropane mg/kg ND 30ND 1,2-Dibromoethane (EDB)mg/kg ND 30ND 1,2-Dichlorobenzene mg/kg ND 30ND 1,2-Dichloroethane mg/kg ND 30ND 1,2-Dichloropropane mg/kg ND 30ND 1,3,5-Trimethylbenzene mg/kg ND 30ND 1,3-Dichlorobenzene mg/kg ND 30ND 1,3-Dichloropropane mg/kg ND 30ND 1,4-Dichlorobenzene mg/kg ND 30ND 2,2-Dichloropropane mg/kg ND 30ND 2-Butanone (MEK)mg/kg ND 30ND 2-Chlorotoluene mg/kg ND 30ND 2-Hexanone mg/kg ND 30ND 4-Chlorotoluene mg/kg ND 30ND 4-Methyl-2-pentanone (MIBK)mg/kg ND 30ND Acetone mg/kg ND 30ND Benzene mg/kg ND 30ND Bromobenzene mg/kg ND 30ND Bromochloromethane mg/kg ND 30ND Bromodichloromethane mg/kg ND 30ND Bromoform mg/kg ND 30ND Bromomethane mg/kg ND 30ND Carbon tetrachloride mg/kg ND 30ND Chlorobenzene mg/kg 0.0044J 30ND Chloroethane mg/kg ND 30ND Chloroform mg/kg ND 30ND Chloromethane mg/kg ND 30ND cis-1,2-Dichloroethene mg/kg ND 30ND cis-1,3-Dichloropropene mg/kg ND 30ND Dibromochloromethane mg/kg ND 30ND Dibromomethane mg/kg ND 30ND Dichlorodifluoromethane mg/kg ND 30ND Diisopropyl ether mg/kg ND 30ND Ethylbenzene mg/kg ND 30ND Hexachloro-1,3-butadiene mg/kg ND 30ND Isopropylbenzene (Cumene)mg/kg ND 30ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 39 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92639512002 3855711SAMPLE DUPLICATE: m&p-Xylene mg/kg ND 30ND Methyl-tert-butyl ether mg/kg ND 30ND Methylene Chloride mg/kg ND 30ND n-Butylbenzene mg/kg ND 30ND n-Propylbenzene mg/kg ND 30ND Naphthalene mg/kg ND 30ND o-Xylene mg/kg 0.0080J 307.0J ug/kg p-Isopropyltoluene mg/kg ND 30ND sec-Butylbenzene mg/kg ND 30ND Styrene mg/kg ND 30ND tert-Butylbenzene mg/kg ND 30ND Tetrachloroethene mg/kg ND 30ND Toluene mg/kg ND 30ND trans-1,2-Dichloroethene mg/kg ND 30ND trans-1,3-Dichloropropene mg/kg ND 30ND Trichloroethene mg/kg ND 30ND Trichlorofluoromethane mg/kg ND 30ND Vinyl acetate mg/kg ND 30ND Vinyl chloride mg/kg ND 30ND Xylene (Total)mg/kg ND 307.0J ug/kg 1,2-Dichloroethane-d4 (S)%107103 4-Bromofluorobenzene (S)%105103 Toluene-d8 (S)%102101 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 40 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 741531 EPA 5035A/5030B EPA 8260D 8260D 5035A 5030B Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92638346001 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3857648 Associated Lab Samples:92638346001 Matrix:Solid AnalyzedMDL 1,1,1,2-Tetrachloroethane mg/kg ND 0.0050 12/06/22 18:180.0019 1,1,1-Trichloroethane mg/kg ND 0.0050 12/06/22 18:180.0026 1,1,2,2-Tetrachloroethane mg/kg ND 0.0050 12/06/22 18:180.0013 1,1,2-Trichloroethane mg/kg ND 0.0050 12/06/22 18:180.0017 1,1-Dichloroethane mg/kg ND 0.0050 12/06/22 18:180.0021 1,1-Dichloroethene mg/kg ND 0.0050 12/06/22 18:180.0021 1,1-Dichloropropene mg/kg ND 0.0050 12/06/22 18:180.0024 1,2,3-Trichlorobenzene mg/kg ND 0.0050 12/06/22 18:180.0040 1,2,3-Trichloropropane mg/kg ND 0.0050 12/06/22 18:180.0025 1,2,4-Trichlorobenzene mg/kg ND 0.0050 12/06/22 18:180.0042 1,2,4-Trimethylbenzene mg/kg ND 0.0050 12/06/22 18:180.0014 1,2-Dibromo-3-chloropropane mg/kg ND 0.0050 12/06/22 18:180.0019 1,2-Dibromoethane (EDB)mg/kg ND 0.0050 12/06/22 18:180.0022 1,2-Dichlorobenzene mg/kg ND 0.0050 12/06/22 18:180.0018 1,2-Dichloroethane mg/kg ND 0.0050 12/06/22 18:180.0033 1,2-Dichloropropane mg/kg ND 0.0050 12/06/22 18:180.0015 1,3,5-Trimethylbenzene mg/kg ND 0.0050 12/06/22 18:180.0017 1,3-Dichlorobenzene mg/kg ND 0.0050 12/06/22 18:180.0016 1,3-Dichloropropane mg/kg ND 0.0050 12/06/22 18:180.0016 1,4-Dichlorobenzene mg/kg ND 0.0050 12/06/22 18:180.0013 2,2-Dichloropropane mg/kg ND 0.0050 IK,v112/06/22 18:180.0016 2-Butanone (MEK)mg/kg ND 0.10 12/06/22 18:180.024 2-Chlorotoluene mg/kg ND 0.0050 12/06/22 18:180.0018 2-Hexanone mg/kg ND 0.050 12/06/22 18:180.0048 4-Chlorotoluene mg/kg ND 0.0050 12/06/22 18:180.00088 4-Methyl-2-pentanone (MIBK)mg/kg ND 0.050 12/06/22 18:180.0048 Acetone mg/kg ND 0.10 12/06/22 18:180.032 Benzene mg/kg ND 0.0050 12/06/22 18:180.0020 Bromobenzene mg/kg ND 0.0050 12/06/22 18:180.0016 Bromochloromethane mg/kg ND 0.0050 12/06/22 18:180.0015 Bromodichloromethane mg/kg ND 0.0050 12/06/22 18:180.0019 Bromoform mg/kg ND 0.0050 12/06/22 18:180.0018 Bromomethane mg/kg ND 0.010 IK12/06/22 18:180.0079 Carbon tetrachloride mg/kg ND 0.0050 12/06/22 18:180.0019 Chlorobenzene mg/kg ND 0.0050 12/06/22 18:180.00096 Chloroethane mg/kg ND 0.010 12/06/22 18:180.0039 Chloroform mg/kg ND 0.0050 12/06/22 18:180.0030 Chloromethane mg/kg ND 0.010 12/06/22 18:180.0042 cis-1,2-Dichloroethene mg/kg ND 0.0050 12/06/22 18:180.0017 cis-1,3-Dichloropropene mg/kg ND 0.0050 12/06/22 18:180.0014 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 41 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3857648 Associated Lab Samples:92638346001 Matrix:Solid AnalyzedMDL Dibromochloromethane mg/kg ND 0.0050 12/06/22 18:180.0028 Dibromomethane mg/kg ND 0.0050 12/06/22 18:180.0011 Dichlorodifluoromethane mg/kg ND 0.010 v112/06/22 18:180.0022 Diisopropyl ether mg/kg ND 0.0050 12/06/22 18:180.0014 Ethylbenzene mg/kg ND 0.0050 12/06/22 18:180.0023 Hexachloro-1,3-butadiene mg/kg ND 0.010 12/06/22 18:180.0082 Isopropylbenzene (Cumene)mg/kg ND 0.0050 12/06/22 18:180.0017 m&p-Xylene mg/kg ND 0.010 12/06/22 18:180.0034 Methyl-tert-butyl ether mg/kg ND 0.0050 12/06/22 18:180.0019 Methylene Chloride mg/kg ND 0.020 IK12/06/22 18:180.014 n-Butylbenzene mg/kg ND 0.0050 12/06/22 18:180.0024 n-Propylbenzene mg/kg ND 0.0050 12/06/22 18:180.0018 Naphthalene mg/kg ND 0.0050 12/06/22 18:180.0026 o-Xylene mg/kg ND 0.0050 12/06/22 18:180.0022 p-Isopropyltoluene mg/kg ND 0.0050 12/06/22 18:180.0025 sec-Butylbenzene mg/kg ND 0.0050 12/06/22 18:180.0022 Styrene mg/kg ND 0.0050 12/06/22 18:180.0013 tert-Butylbenzene mg/kg ND 0.0050 12/06/22 18:180.0018 Tetrachloroethene mg/kg ND 0.0050 12/06/22 18:180.0016 Toluene mg/kg ND 0.0050 12/06/22 18:180.0014 trans-1,2-Dichloroethene mg/kg ND 0.0050 12/06/22 18:180.0018 trans-1,3-Dichloropropene mg/kg ND 0.0050 12/06/22 18:180.0017 Trichloroethene mg/kg ND 0.0050 12/06/22 18:180.0013 Trichlorofluoromethane mg/kg ND 0.0050 12/06/22 18:180.0028 Vinyl acetate mg/kg ND 0.050 IK12/06/22 18:180.0036 Vinyl chloride mg/kg ND 0.010 12/06/22 18:180.0025 Xylene (Total)mg/kg ND 0.010 12/06/22 18:180.0028 1,2-Dichloroethane-d4 (S)%123 70-130 12/06/22 18:18 4-Bromofluorobenzene (S)%98 70-130 12/06/22 18:18 Toluene-d8 (S)%102 70-130 12/06/22 18:18 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3857649LABORATORY CONTROL SAMPLE: LCSSpike 1,1,1,2-Tetrachloroethane mg/kg 1.31.2 103 70-130 1,1,1-Trichloroethane mg/kg 1.41.2 109 70-130 1,1,2,2-Tetrachloroethane mg/kg 1.31.2 105 70-130 1,1,2-Trichloroethane mg/kg 1.31.2 105 70-130 1,1-Dichloroethane mg/kg 1.41.2 110 70-130 1,1-Dichloroethene mg/kg 1.41.2 112 70-130 1,1-Dichloropropene mg/kg 1.41.2 110 70-130 1,2,3-Trichlorobenzene mg/kg 1.31.2 104 70-130 1,2,3-Trichloropropane mg/kg 1.31.2 106 70-130 1,2,4-Trichlorobenzene mg/kg 1.21.2 99 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 42 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3857649LABORATORY CONTROL SAMPLE: LCSSpike 1,2,4-Trimethylbenzene mg/kg 1.21.2 97 70-130 1,2-Dibromo-3-chloropropane mg/kg 1.21.2 99 67-130 1,2-Dibromoethane (EDB)mg/kg 1.31.2 105 70-130 1,2-Dichlorobenzene mg/kg 1.21.2 98 70-130 1,2-Dichloroethane mg/kg 1.31.2 105 70-130 1,2-Dichloropropane mg/kg 1.31.2 104 70-130 1,3,5-Trimethylbenzene mg/kg 1.31.2 104 70-130 1,3-Dichlorobenzene mg/kg 1.21.2 96 70-130 1,3-Dichloropropane mg/kg 1.31.2 102 70-130 1,4-Dichlorobenzene mg/kg 1.11.2 90 70-130 2,2-Dichloropropane mg/kg 1.5 IK,v11.2 123 67-130 2-Butanone (MEK)mg/kg 2.82.5 110 66-130 2-Chlorotoluene mg/kg 1.31.2 100 70-130 2-Hexanone mg/kg 2.92.5 117 70-130 4-Chlorotoluene mg/kg 1.21.2 99 70-130 4-Methyl-2-pentanone (MIBK)mg/kg 2.82.5 111 70-130 Acetone mg/kg 2.72.5 106 67-130 Benzene mg/kg 1.21.2 94 70-130 Bromobenzene mg/kg 1.21.2 99 70-130 Bromochloromethane mg/kg 1.31.2 106 70-130 Bromodichloromethane mg/kg 1.31.2 104 70-130 Bromoform mg/kg 1.31.2 107 70-130 Bromomethane mg/kg 1.7 IK1.2 135 53-175 Carbon tetrachloride mg/kg 1.41.2 115 70-130 Chlorobenzene mg/kg 1.31.2 100 70-130 Chloroethane mg/kg 1.51.2 118 70-135 Chloroform mg/kg 1.31.2 107 70-130 Chloromethane mg/kg 1.31.2 103 64-130 cis-1,2-Dichloroethene mg/kg 1.31.2 107 70-130 cis-1,3-Dichloropropene mg/kg 1.41.2 111 70-130 Dibromochloromethane mg/kg 1.41.2 109 70-130 Dibromomethane mg/kg 1.21.2 98 70-130 Dichlorodifluoromethane mg/kg 1.6 v11.2 127 63-145 Diisopropyl ether mg/kg 1.31.2 106 68-130 Ethylbenzene mg/kg 1.21.2 95 70-130 Hexachloro-1,3-butadiene mg/kg 1.21.2 93 70-130 Isopropylbenzene (Cumene)mg/kg 1.21.2 100 70-130 m&p-Xylene mg/kg 2.52.5 101 70-130 Methyl-tert-butyl ether mg/kg 1.21.2 99 70-130 Methylene Chloride mg/kg 1.1 IK1.2 92 67-130 n-Butylbenzene mg/kg 1.31.2 104 70-130 n-Propylbenzene mg/kg 1.31.2 101 70-130 Naphthalene mg/kg 1.41.2 111 70-130 o-Xylene mg/kg 1.31.2 102 70-130 p-Isopropyltoluene mg/kg 1.31.2 103 70-130 sec-Butylbenzene mg/kg 1.21.2 100 70-130 Styrene mg/kg 1.41.2 109 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 43 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3857649LABORATORY CONTROL SAMPLE: LCSSpike tert-Butylbenzene mg/kg 1.31.2 101 64-130 Tetrachloroethene mg/kg 1.31.2 100 70-130 Toluene mg/kg 1.21.2 96 70-130 trans-1,2-Dichloroethene mg/kg 1.41.2 110 70-130 trans-1,3-Dichloropropene mg/kg 1.41.2 113 70-130 Trichloroethene mg/kg 1.21.2 95 70-130 Trichlorofluoromethane mg/kg 1.51.2 117 70-130 Vinyl acetate mg/kg 2.9 IK2.5 114 70-134 Vinyl chloride mg/kg 1.51.2 123 68-130 Xylene (Total)mg/kg 3.83.8 102 70-130 1,2-Dichloroethane-d4 (S)%103 70-130 4-Bromofluorobenzene (S)%105 70-130 Toluene-d8 (S)%103 70-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3857650MATRIX SPIKE SAMPLE: MSSpike Result 92639975001 1,1,1,2-Tetrachloroethane mg/kg 0.930.96 98 58-140ND 1,1,1-Trichloroethane mg/kg 1.10.96 118 58-144ND 1,1,2,2-Tetrachloroethane mg/kg 1.00.96 107 52-139ND 1,1,2-Trichloroethane mg/kg 1.10.96 114 56-140ND 1,1-Dichloroethane mg/kg 1.20.96 128 58-145ND 1,1-Dichloroethene mg/kg 1.30.96 137 57-158ND 1,1-Dichloropropene mg/kg 1.20.96 127 58-151ND 1,2,3-Trichlorobenzene mg/kg 0.840.96 87 48-149ND 1,2,3-Trichloropropane mg/kg 1.00.96 107 54-132ND 1,2,4-Trichlorobenzene mg/kg 0.920.96 96 51-151ND 1,2,4-Trimethylbenzene mg/kg 1.10.96 112 38-1706.7J ug/kg 1,2-Dibromo-3-chloropropane mg/kg 0.700.96 73 44-134ND 1,2-Dibromoethane (EDB)mg/kg 0.990.96 103 60-138ND 1,2-Dichlorobenzene mg/kg 1.00.96 105 59-147ND 1,2-Dichloroethane mg/kg 1.10.96 119 57-139ND 1,2-Dichloropropane mg/kg 1.10.96 110 62-145ND 1,3,5-Trimethylbenzene mg/kg 1.10.96 113 47-159ND 1,3-Dichlorobenzene mg/kg 1.00.96 108 58-144ND 1,3-Dichloropropane mg/kg 1.00.96 109 60-142ND 1,4-Dichlorobenzene mg/kg 0.950.96 99 57-143ND 2,2-Dichloropropane mg/kg 1.2 IK,v10.96 129 37-144ND 2-Butanone (MEK)mg/kg 2.11.9 110 28-146ND 2-Chlorotoluene mg/kg 1.10.96 111 55-158ND 2-Hexanone mg/kg 2.01.9 105 44-141ND 4-Chlorotoluene mg/kg 1.10.96 111 55-146ND 4-Methyl-2-pentanone (MIBK)mg/kg 2.11.9 109 50-138ND Acetone mg/kg 2.11.9 110 20-136ND Benzene mg/kg 1.00.96 107 60-145ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 44 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3857650MATRIX SPIKE SAMPLE: MSSpike Result 92639975001 Bromobenzene mg/kg 1.00.96 106 59-145ND Bromochloromethane mg/kg 1.10.96 114 57-143ND Bromodichloromethane mg/kg 0.970.96 101 53-133ND Bromoform mg/kg 0.840.96 87 48-133ND Bromomethane mg/kg 0.95 IK0.96 99 10-167ND Carbon tetrachloride mg/kg 1.00.96 105 57-147ND Chlorobenzene mg/kg 1.00.96 108 61-144ND Chloroethane mg/kg 0.510.96 53 10-153ND Chloroform mg/kg 1.10.96 119 58-141ND Chloromethane mg/kg 1.30.96 131 54-165ND cis-1,2-Dichloroethene mg/kg 1.20.96 124 59-144ND cis-1,3-Dichloropropene mg/kg 1.10.96 115 56-137ND Dibromochloromethane mg/kg 0.910.96 95 53-139ND Dibromomethane mg/kg 0.900.96 94 60-136ND Dichlorodifluoromethane mg/kg 1.6 v10.96 166 49-177ND Diisopropyl ether mg/kg 1.10.96 118 53-136ND Ethylbenzene mg/kg 0.990.96 103 53-150ND Hexachloro-1,3-butadiene mg/kg 0.970.96 101 42-186ND Isopropylbenzene (Cumene)mg/kg 1.00.96 108 62-154ND m&p-Xylene mg/kg 2.11.9 110 49-156ND Methyl-tert-butyl ether mg/kg 1.10.96 110 54-133ND Methylene Chloride mg/kg 0.83 IK0.96 87 50-153ND n-Butylbenzene mg/kg 1.10.96 118 44-174ND n-Propylbenzene mg/kg 1.10.96 112 52-157ND Naphthalene mg/kg 0.870.96 90 37-150ND o-Xylene mg/kg 1.00.96 108 54-150ND p-Isopropyltoluene mg/kg 1.10.96 118 50-164ND sec-Butylbenzene mg/kg 1.10.96 116 58-161ND Styrene mg/kg 1.10.96 110 60-148ND tert-Butylbenzene mg/kg 1.00.96 109 44-151ND Tetrachloroethene mg/kg 0.980.96 103 53-151ND Toluene mg/kg 1.00.96 107 52-1488.1J ug/kg trans-1,2-Dichloroethene mg/kg 1.20.96 128 60-148ND trans-1,3-Dichloropropene mg/kg 1.10.96 117 55-133ND Trichloroethene mg/kg 1.00.96 106 60-148ND Trichlorofluoromethane mg/kg 0.880.96 91 10-154ND Vinyl acetate mg/kg 2.4 IK1.9 125 50-149ND Vinyl chloride mg/kg 1.40.96 145 57-157ND Xylene (Total)mg/kg 3.12.9 109 52-153ND 1,2-Dichloroethane-d4 (S)%120 70-130 4-Bromofluorobenzene (S)%104 70-130 Toluene-d8 (S)%102 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 45 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92639975002 3857651SAMPLE DUPLICATE: 1,1,1,2-Tetrachloroethane mg/kg ND 30ND 1,1,1-Trichloroethane mg/kg ND 30ND 1,1,2,2-Tetrachloroethane mg/kg ND 30ND 1,1,2-Trichloroethane mg/kg ND 30ND 1,1-Dichloroethane mg/kg ND 30ND 1,1-Dichloroethene mg/kg ND 30ND 1,1-Dichloropropene mg/kg ND 30ND 1,2,3-Trichlorobenzene mg/kg ND 30ND 1,2,3-Trichloropropane mg/kg ND 30ND 1,2,4-Trichlorobenzene mg/kg ND 30ND 1,2,4-Trimethylbenzene mg/kg 0.030 6 3028.3 ug/kg 1,2-Dibromo-3-chloropropane mg/kg ND 30ND 1,2-Dibromoethane (EDB)mg/kg ND 30ND 1,2-Dichlorobenzene mg/kg ND 30ND 1,2-Dichloroethane mg/kg ND 30ND 1,2-Dichloropropane mg/kg ND 30ND 1,3,5-Trimethylbenzene mg/kg 0.011J 309.3J ug/kg 1,3-Dichlorobenzene mg/kg ND 30ND 1,3-Dichloropropane mg/kg ND 30ND 1,4-Dichlorobenzene mg/kg ND 30ND 2,2-Dichloropropane mg/kg ND IK,v130ND 2-Butanone (MEK)mg/kg ND 30ND 2-Chlorotoluene mg/kg ND 30ND 2-Hexanone mg/kg ND 30ND 4-Chlorotoluene mg/kg ND 30ND 4-Methyl-2-pentanone (MIBK)mg/kg ND 30ND Acetone mg/kg ND 30ND Benzene mg/kg ND 30ND Bromobenzene mg/kg ND 30ND Bromochloromethane mg/kg ND 30ND Bromodichloromethane mg/kg ND 30ND Bromoform mg/kg ND 30ND Bromomethane mg/kg ND IK30ND Carbon tetrachloride mg/kg ND 30ND Chlorobenzene mg/kg ND 30ND Chloroethane mg/kg ND 30ND Chloroform mg/kg ND 30ND Chloromethane mg/kg ND 30ND cis-1,2-Dichloroethene mg/kg ND 30ND cis-1,3-Dichloropropene mg/kg ND 30ND Dibromochloromethane mg/kg ND 30ND Dibromomethane mg/kg ND 30ND Dichlorodifluoromethane mg/kg ND v130ND Diisopropyl ether mg/kg ND 30ND Ethylbenzene mg/kg ND 30ND Hexachloro-1,3-butadiene mg/kg ND 30ND Isopropylbenzene (Cumene)mg/kg ND 30ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 46 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92639975002 3857651SAMPLE DUPLICATE: m&p-Xylene mg/kg ND 30ND Methyl-tert-butyl ether mg/kg ND 30ND Methylene Chloride mg/kg ND IK30ND n-Butylbenzene mg/kg ND 30ND n-Propylbenzene mg/kg ND 30ND Naphthalene mg/kg ND 30ND o-Xylene mg/kg ND 30ND p-Isopropyltoluene mg/kg ND 30ND sec-Butylbenzene mg/kg ND 30ND Styrene mg/kg ND 30ND tert-Butylbenzene mg/kg ND 30ND Tetrachloroethene mg/kg ND 30ND Toluene mg/kg ND 30ND trans-1,2-Dichloroethene mg/kg ND 30ND trans-1,3-Dichloropropene mg/kg ND 30ND Trichloroethene mg/kg ND 30ND Trichlorofluoromethane mg/kg ND 30ND Vinyl acetate mg/kg ND IK30ND Vinyl chloride mg/kg ND 30ND Xylene (Total)mg/kg ND 30ND 1,2-Dichloroethane-d4 (S)%119119 4-Bromofluorobenzene (S)%101102 Toluene-d8 (S)%103103 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 47 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 740092 EPA 3546 EPA 8015C 8015 Solid GCSV Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92638346004, 92638346005, 92638346007, 92638346012, 92638346013, 92638346014, 92638346015 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3850479 Associated Lab Samples:92638346004, 92638346005, 92638346007, 92638346012, 92638346013, 92638346014, 92638346015 Matrix:Solid AnalyzedMDL Diesel Range Organics(C10-C28)mg/kg ND 5.1 12/01/22 16:283.6 n-Pentacosane (S)%81 10-130 12/01/22 16:28 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3850480LABORATORY CONTROL SAMPLE: LCSSpike Diesel Range Organics(C10-C28)mg/kg 74.066.7 111 44-130 n-Pentacosane (S)%80 10-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3850481MATRIX SPIKE SAMPLE: MSSpike Result 92638204001 Diesel Range Organics(C10-C28)mg/kg 23400 M185.9 3500 10-13020400 n-Pentacosane (S)%S036810-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92638204002 3850482SAMPLE DUPLICATE: Diesel Range Organics(C10-C28)mg/kg 12000 7 3012800 n-Pentacosane (S)%0 S40 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 48 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 741034 EPA 3546 EPA 8270E 8270E Solid MSSV Microwave Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92638346016 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3854964 Associated Lab Samples:92638346016 Matrix:Solid AnalyzedMDL 1,2,4-Trichlorobenzene ug/kg ND 326 12/05/22 14:15128 1,2-Dichlorobenzene ug/kg ND 326 12/05/22 14:15117 1,3-Dichlorobenzene ug/kg ND 326 12/05/22 14:15115 1,4-Dichlorobenzene ug/kg ND 326 12/05/22 14:15124 1-Methylnaphthalene ug/kg ND 326 12/05/22 14:15114 2,2'-Oxybis(1-chloropropane)ug/kg ND 326 12/05/22 14:15155 2,4,5-Trichlorophenol ug/kg ND 326 12/05/22 14:15149 2,4,6-Trichlorophenol ug/kg ND 326 12/05/22 14:15134 2,4-Dichlorophenol ug/kg ND 326 12/05/22 14:15127 2,4-Dimethylphenol ug/kg ND 326 12/05/22 14:15135 2,4-Dinitrophenol ug/kg ND 1630 12/05/22 14:151010 2,4-Dinitrotoluene ug/kg ND 326 12/05/22 14:15125 2,6-Dinitrotoluene ug/kg ND 326 12/05/22 14:15119 2-Chloronaphthalene ug/kg ND 326 12/05/22 14:15129 2-Chlorophenol ug/kg ND 326 12/05/22 14:15122 2-Methylnaphthalene ug/kg ND 326 12/05/22 14:15130 2-Methylphenol(o-Cresol)ug/kg ND 326 12/05/22 14:15133 2-Nitroaniline ug/kg ND 1630 12/05/22 14:15266 2-Nitrophenol ug/kg ND 326 12/05/22 14:15141 3&4-Methylphenol(m&p Cresol)ug/kg ND 326 12/05/22 14:15131 3,3'-Dichlorobenzidine ug/kg ND 651 v212/05/22 14:15220 3-Nitroaniline ug/kg ND 1630 12/05/22 14:15256 4,6-Dinitro-2-methylphenol ug/kg ND 651 12/05/22 14:15304 4-Bromophenylphenyl ether ug/kg ND 326 12/05/22 14:15125 4-Chloro-3-methylphenol ug/kg ND 651 12/05/22 14:15229 4-Chloroaniline ug/kg ND 651 12/05/22 14:15256 4-Chlorophenylphenyl ether ug/kg ND 326 12/05/22 14:15121 4-Nitroaniline ug/kg ND 651 12/05/22 14:15248 4-Nitrophenol ug/kg ND 1630 12/05/22 14:15630 Acenaphthene ug/kg ND 326 12/05/22 14:15114 Acenaphthylene ug/kg ND 326 12/05/22 14:15114 Aniline ug/kg ND 326 12/05/22 14:15127 Anthracene ug/kg ND 326 12/05/22 14:15107 Benzo(a)anthracene ug/kg ND 326 12/05/22 14:15109 Benzo(a)pyrene ug/kg ND 326 12/05/22 14:15112 Benzo(b)fluoranthene ug/kg ND 326 12/05/22 14:15109 Benzo(g,h,i)perylene ug/kg ND 326 12/05/22 14:15126 Benzo(k)fluoranthene ug/kg ND 326 12/05/22 14:15114 Benzoic Acid ug/kg ND 1630 12/05/22 14:15700 Benzyl alcohol ug/kg ND 651 12/05/22 14:15247 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 49 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3854964 Associated Lab Samples:92638346016 Matrix:Solid AnalyzedMDL bis(2-Chloroethoxy)methane ug/kg ND 326 12/05/22 14:15135 bis(2-Chloroethyl) ether ug/kg ND 326 12/05/22 14:15122 bis(2-Ethylhexyl)phthalate ug/kg ND 326 12/05/22 14:15126 Butylbenzylphthalate ug/kg ND 326 12/05/22 14:15137 Chrysene ug/kg ND 326 v212/05/22 14:15118 Di-n-butylphthalate ug/kg ND 326 12/05/22 14:15110 Di-n-octylphthalate ug/kg ND 326 12/05/22 14:15128 Dibenz(a,h)anthracene ug/kg ND 326 12/05/22 14:15125 Dibenzofuran ug/kg ND 326 12/05/22 14:15117 Diethylphthalate ug/kg ND 326 12/05/22 14:15119 Dimethylphthalate ug/kg ND 326 12/05/22 14:15118 Fluoranthene ug/kg ND 326 12/05/22 14:15112 Fluorene ug/kg ND 326 12/05/22 14:15114 Hexachloro-1,3-butadiene ug/kg ND 326 12/05/22 14:15141 Hexachlorobenzene ug/kg ND 326 12/05/22 14:15127 Hexachlorocyclopentadiene ug/kg ND 326 12/05/22 14:15187 Hexachloroethane ug/kg ND 326 12/05/22 14:15124 Indeno(1,2,3-cd)pyrene ug/kg ND 326 12/05/22 14:15128 Isophorone ug/kg ND 326 12/05/22 14:15145 N-Nitroso-di-n-propylamine ug/kg ND 326 12/05/22 14:15122 N-Nitrosodimethylamine ug/kg ND 326 12/05/22 14:15110 N-Nitrosodiphenylamine ug/kg ND 326 12/05/22 14:15115 Naphthalene ug/kg ND 326 12/05/22 14:15111 Nitrobenzene ug/kg ND 326 12/05/22 14:15151 Pentachlorophenol ug/kg ND 651 12/05/22 14:15319 Phenanthrene ug/kg ND 326 12/05/22 14:15107 Phenol ug/kg ND 326 12/05/22 14:15145 Pyrene ug/kg ND 326 12/05/22 14:15132 Pyridine ug/kg ND 326 12/05/22 14:15103 2,4,6-Tribromophenol (S)%73 10-131 12/05/22 14:15 2-Fluorobiphenyl (S)%65 10-130 12/05/22 14:15 2-Fluorophenol (S)%69 10-130 12/05/22 14:15 Nitrobenzene-d5 (S)%66 10-130 12/05/22 14:15 Phenol-d6 (S)%72 10-130 12/05/22 14:15 Terphenyl-d14 (S)%82 10-130 12/05/22 14:15 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3854965LABORATORY CONTROL SAMPLE: LCSSpike 1,2,4-Trichlorobenzene ug/kg 11201660 68 43-130 1,2-Dichlorobenzene ug/kg 11401660 69 43-130 1,3-Dichlorobenzene ug/kg 11201660 68 43-130 1,4-Dichlorobenzene ug/kg 11201660 67 44-130 1-Methylnaphthalene ug/kg 12301660 74 47-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 50 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3854965LABORATORY CONTROL SAMPLE: LCSSpike 2,2'-Oxybis(1-chloropropane)ug/kg 10301660 62 29-130 2,4,5-Trichlorophenol ug/kg 11901660 72 47-130 2,4,6-Trichlorophenol ug/kg 11701660 71 47-130 2,4-Dichlorophenol ug/kg 11701660 70 45-130 2,4-Dimethylphenol ug/kg 14401660 87 45-130 2,4-Dinitrophenol ug/kg 63308280 76 27-140 2,4-Dinitrotoluene ug/kg 13601660 82 46-130 2,6-Dinitrotoluene ug/kg 13901660 84 48-130 2-Chloronaphthalene ug/kg 12401660 75 46-130 2-Chlorophenol ug/kg 11601660 70 43-130 2-Methylnaphthalene ug/kg 11801660 71 47-130 2-Methylphenol(o-Cresol)ug/kg 11601660 70 42-130 2-Nitroaniline ug/kg 22603310 68 41-130 2-Nitrophenol ug/kg 12301660 74 48-130 3&4-Methylphenol(m&p Cresol)ug/kg 11801660 72 39-130 3,3'-Dichlorobenzidine ug/kg 2320 v333107041-130 3-Nitroaniline ug/kg 21803310 66 37-130 4,6-Dinitro-2-methylphenol ug/kg 27203310 82 38-141 4-Bromophenylphenyl ether ug/kg 13201660 79 47-130 4-Chloro-3-methylphenol ug/kg 24603310 74 44-130 4-Chloroaniline ug/kg 21703310 65 41-130 4-Chlorophenylphenyl ether ug/kg 12001660 73 45-130 4-Nitroaniline ug/kg 23603310 71 42-130 4-Nitrophenol ug/kg 59708280 72 39-131 Acenaphthene ug/kg 12401660 75 49-130 Acenaphthylene ug/kg 12401660 75 50-130 Aniline ug/kg 9401660 57 38-130 Anthracene ug/kg 12301660 74 49-130 Benzo(a)anthracene ug/kg 13701660 82 51-130 Benzo(a)pyrene ug/kg 13001660 79 51-130 Benzo(b)fluoranthene ug/kg 13301660 80 49-130 Benzo(g,h,i)perylene ug/kg 13701660 83 48-140 Benzo(k)fluoranthene ug/kg 13601660 82 51-130 Benzoic Acid ug/kg 53608280 65 22-130 Benzyl alcohol ug/kg 23703310 72 43-130 bis(2-Chloroethoxy)methane ug/kg 11901660 72 43-130 bis(2-Chloroethyl) ether ug/kg 11301660 68 42-130 bis(2-Ethylhexyl)phthalate ug/kg 15001660 90 43-130 Butylbenzylphthalate ug/kg 16301660 98 44-131 Chrysene ug/kg 1330 v316608151-130 Di-n-butylphthalate ug/kg 13901660 84 46-130 Di-n-octylphthalate ug/kg 15001660 90 45-130 Dibenz(a,h)anthracene ug/kg 14101660 85 48-130 Dibenzofuran ug/kg 12601660 76 10-130 Diethylphthalate ug/kg 13201660 80 48-130 Dimethylphthalate ug/kg 12801660 78 48-130 Fluoranthene ug/kg 12301660 74 48-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 51 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3854965LABORATORY CONTROL SAMPLE: LCSSpike Fluorene ug/kg 12201660 74 48-130 Hexachloro-1,3-butadiene ug/kg 10301660 62 39-130 Hexachlorobenzene ug/kg 12901660 78 47-130 Hexachlorocyclopentadiene ug/kg 9451660 57 17-130 Hexachloroethane ug/kg 11401660 69 40-130 Indeno(1,2,3-cd)pyrene ug/kg 13401660 81 50-130 Isophorone ug/kg 11701660 71 41-130 N-Nitroso-di-n-propylamine ug/kg 12101660 73 36-130 N-Nitrosodimethylamine ug/kg 10601660 64 34-130 N-Nitrosodiphenylamine ug/kg 13301660 80 48-130 Naphthalene ug/kg 11401660 69 46-130 Nitrobenzene ug/kg 11301660 68 39-130 Pentachlorophenol ug/kg 23803310 72 42-130 Phenanthrene ug/kg 13301660 80 50-130 Phenol ug/kg 12601660 76 42-130 Pyrene ug/kg 14801660 89 50-130 Pyridine ug/kg 9471660 57 26-130 2,4,6-Tribromophenol (S)%81 10-131 2-Fluorobiphenyl (S)%68 10-130 2-Fluorophenol (S)%66 10-130 Nitrobenzene-d5 (S)%65 10-130 Phenol-d6 (S)%71 10-130 Terphenyl-d14 (S)%87 10-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3854966MATRIX SPIKE SAMPLE: MSSpike Result 92639042001 1,2,4-Trichlorobenzene ug/kg 13301950 68 16-130ND 1,2-Dichlorobenzene ug/kg 13901950 71 19-130ND 1,3-Dichlorobenzene ug/kg 13701950 70 19-130ND 1,4-Dichlorobenzene ug/kg 13801950 71 20-130ND 1-Methylnaphthalene ug/kg 14601950 75 19-130ND 2,2'-Oxybis(1-chloropropane)ug/kg 12901950 66 10-130ND 2,4,5-Trichlorophenol ug/kg 16001950 82 19-130ND 2,4,6-Trichlorophenol ug/kg 15701950 80 18-130ND 2,4-Dichlorophenol ug/kg 15201950 78 16-130ND 2,4-Dimethylphenol ug/kg 19001950 98 10-130ND 2,4-Dinitrophenol ug/kg 88209750 90 10-143ND 2,4-Dinitrotoluene ug/kg 18401950 94 19-130ND 2,6-Dinitrotoluene ug/kg 18201950 94 22-130ND 2-Chloronaphthalene ug/kg 14701950 76 18-130ND 2-Chlorophenol ug/kg 14601950 75 20-130ND 2-Methylnaphthalene ug/kg 14001950 72 18-130ND 2-Methylphenol(o-Cresol)ug/kg 15001950 77 13-130ND 2-Nitroaniline ug/kg 30503900 78 18-130ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 52 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3854966MATRIX SPIKE SAMPLE: MSSpike Result 92639042001 2-Nitrophenol ug/kg 15901950 81 19-130ND 3&4-Methylphenol(m&p Cresol)ug/kg 15101950 78 13-130ND 3,3'-Dichlorobenzidine ug/kg 3110 v339008010-130ND 3-Nitroaniline ug/kg 32303900 83 22-130ND 4,6-Dinitro-2-methylphenol ug/kg 36903900 95 10-144ND 4-Bromophenylphenyl ether ug/kg 15401950 79 18-130ND 4-Chloro-3-methylphenol ug/kg 33003900 85 16-130ND 4-Chloroaniline ug/kg 29303900 75 17-130ND 4-Chlorophenylphenyl ether ug/kg 14101950 72 17-130ND 4-Nitroaniline ug/kg 33603900 86 21-130ND 4-Nitrophenol ug/kg 84009750 86 13-131ND Acenaphthene ug/kg 14601950 75 20-130ND Acenaphthylene ug/kg 14801950 76 21-130ND Aniline ug/kg 11601950 60 10-130ND Anthracene ug/kg 14301950 74 19-130ND Benzo(a)anthracene ug/kg 15701950 80 17-130ND Benzo(a)pyrene ug/kg 15001950 77 14-130ND Benzo(b)fluoranthene ug/kg 15601950 80 11-134ND Benzo(g,h,i)perylene ug/kg 15601950 80 12-130ND Benzo(k)fluoranthene ug/kg 15801950 81 15-130ND Benzoic Acid ug/kg 76109750 78 10-130ND Benzyl alcohol ug/kg 30603900 78 20-130ND bis(2-Chloroethoxy)methane ug/kg 15101950 77 16-130ND bis(2-Chloroethyl) ether ug/kg 14201950 73 18-130ND bis(2-Ethylhexyl)phthalate ug/kg 17801950 91 11-130ND Butylbenzylphthalate ug/kg 19001950 97 10-130ND Chrysene ug/kg 1530 v319507917-130ND Di-n-butylphthalate ug/kg 16101950 83 16-130ND Di-n-octylphthalate ug/kg 18301950 94 16-130ND Dibenz(a,h)anthracene ug/kg 15901950 81 13-130ND Dibenzofuran ug/kg 14901950 77 19-130ND Diethylphthalate ug/kg 17001950 87 22-130ND Dimethylphthalate ug/kg 17101950 88 23-130ND Fluoranthene ug/kg 14701950 75 14-130ND Fluorene ug/kg 14701950 75 19-130ND Hexachloro-1,3-butadiene ug/kg 11701950 60 12-130ND Hexachlorobenzene ug/kg 15301950 79 17-130ND Hexachlorocyclopentadiene ug/kg 10501950 54 10-130ND Hexachloroethane ug/kg 13201950 67 14-130ND Indeno(1,2,3-cd)pyrene ug/kg 15501950 79 13-130ND Isophorone ug/kg 15501950 80 17-130ND N-Nitroso-di-n-propylamine ug/kg 15701950 81 10-130ND N-Nitrosodimethylamine ug/kg 13301950 68 16-130ND N-Nitrosodiphenylamine ug/kg 16201950 83 19-130ND Naphthalene ug/kg 13801950 71 18-130ND Nitrobenzene ug/kg 14401950 74 15-130ND Pentachlorophenol ug/kg 32603900 84 10-130ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 53 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3854966MATRIX SPIKE SAMPLE: MSSpike Result 92639042001 Phenanthrene ug/kg 15601950 80 17-130ND Phenol ug/kg 15701950 81 15-130ND Pyrene ug/kg 16901950 87 31-130ND Pyridine ug/kg 6411950 33 10-130ND 2,4,6-Tribromophenol (S)%77 10-131 2-Fluorobiphenyl (S)%55 10-130 2-Fluorophenol (S)%64 10-130 Nitrobenzene-d5 (S)%64 10-130 Phenol-d6 (S)%67 10-130 Terphenyl-d14 (S)%74 10-130 Parameter Units Dup Result Max RPD QualifiersRPDResult 92639042003 3854967SAMPLE DUPLICATE: 1,2,4-Trichlorobenzene ug/kg ND 30ND 1,2-Dichlorobenzene ug/kg ND 30ND 1,3-Dichlorobenzene ug/kg ND 30ND 1,4-Dichlorobenzene ug/kg ND 30ND 1-Methylnaphthalene ug/kg ND 30ND 2,2'-Oxybis(1-chloropropane)ug/kg ND 30ND 2,4,5-Trichlorophenol ug/kg ND 30ND 2,4,6-Trichlorophenol ug/kg ND 30ND 2,4-Dichlorophenol ug/kg ND 30ND 2,4-Dimethylphenol ug/kg ND 30ND 2,4-Dinitrophenol ug/kg ND 30ND 2,4-Dinitrotoluene ug/kg ND 30ND 2,6-Dinitrotoluene ug/kg ND 30ND 2-Chloronaphthalene ug/kg ND 30ND 2-Chlorophenol ug/kg ND 30ND 2-Methylnaphthalene ug/kg ND 30ND 2-Methylphenol(o-Cresol)ug/kg ND 30ND 2-Nitroaniline ug/kg ND 30ND 2-Nitrophenol ug/kg ND 30ND 3&4-Methylphenol(m&p Cresol)ug/kg ND 30ND 3,3'-Dichlorobenzidine ug/kg ND 30ND 3-Nitroaniline ug/kg ND 30ND 4,6-Dinitro-2-methylphenol ug/kg ND 30ND 4-Bromophenylphenyl ether ug/kg ND 30ND 4-Chloro-3-methylphenol ug/kg ND 30ND 4-Chloroaniline ug/kg ND 30ND 4-Chlorophenylphenyl ether ug/kg ND 30ND 4-Nitroaniline ug/kg ND 30ND 4-Nitrophenol ug/kg ND 30ND Acenaphthene ug/kg ND 30ND Acenaphthylene ug/kg ND 30ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 54 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result Max RPD QualifiersRPDResult 92639042003 3854967SAMPLE DUPLICATE: Aniline ug/kg ND 30ND Anthracene ug/kg ND 30ND Benzo(a)anthracene ug/kg ND 30ND Benzo(a)pyrene ug/kg ND 30ND Benzo(b)fluoranthene ug/kg ND 30ND Benzo(g,h,i)perylene ug/kg ND 30ND Benzo(k)fluoranthene ug/kg ND 30ND Benzoic Acid ug/kg ND 30ND Benzyl alcohol ug/kg ND 30ND bis(2-Chloroethoxy)methane ug/kg ND 30ND bis(2-Chloroethyl) ether ug/kg ND 30ND bis(2-Ethylhexyl)phthalate ug/kg ND 30ND Butylbenzylphthalate ug/kg ND 30ND Chrysene ug/kg ND 30ND Di-n-butylphthalate ug/kg ND 30ND Di-n-octylphthalate ug/kg ND 30ND Dibenz(a,h)anthracene ug/kg ND 30ND Dibenzofuran ug/kg ND 30ND Diethylphthalate ug/kg ND 30ND Dimethylphthalate ug/kg ND 30ND Fluoranthene ug/kg ND 30ND Fluorene ug/kg ND 30ND Hexachloro-1,3-butadiene ug/kg ND 30ND Hexachlorobenzene ug/kg ND 30ND Hexachlorocyclopentadiene ug/kg ND 30ND Hexachloroethane ug/kg ND 30ND Indeno(1,2,3-cd)pyrene ug/kg ND 30ND Isophorone ug/kg ND 30ND N-Nitroso-di-n-propylamine ug/kg ND 30ND N-Nitrosodimethylamine ug/kg ND 30ND N-Nitrosodiphenylamine ug/kg ND 30ND Naphthalene ug/kg ND 30ND Nitrobenzene ug/kg ND 30ND Pentachlorophenol ug/kg ND 30ND Phenanthrene ug/kg ND 30ND Phenol ug/kg ND 30ND Pyrene ug/kg ND 30ND Pyridine ug/kg ND 30ND 2,4,6-Tribromophenol (S)%6759 2-Fluorobiphenyl (S)%4842 2-Fluorophenol (S)%6766 Nitrobenzene-d5 (S)%6562 Phenol-d6 (S)%6967 Terphenyl-d14 (S)%6960 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 55 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 741187 MADEP EPH MADEP EPH MADEP EPH NC Soil Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92638346016 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:3855801 Associated Lab Samples:92638346016 Matrix:Solid AnalyzedMDL Aliphatic (C09-C18)mg/kg ND 10 N212/07/22 07:2810 Aliphatic (C19-C36)mg/kg ND 10 N212/07/22 07:2810 Aromatic (C11-C22)mg/kg ND 10 N212/07/22 07:2810 1-Chlorooctadecane (S)%74 40-140 12/07/22 07:28 2-Bromonaphthalene (S)%103 40-140 12/07/22 07:28 2-Fluorobiphenyl (S)%96 40-140 12/07/22 07:28 o-Terphenyl (S)%82 40-140 12/07/22 07:28 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3855802LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 3855803 Aliphatic (C09-C18)mg/kg ND N29.9 53 40-14056ND 50 Aliphatic (C19-C36)mg/kg 11.1 N213.2 84 40-1408411.2 1 50 Aromatic (C11-C22)mg/kg 23.5 N228.1 84 40-1408122.9 2 50 1-Chlorooctadecane (S)%83 40-14081 2-Bromonaphthalene (S)%103 40-14097 2-Fluorobiphenyl (S)%99 40-14093 o-Terphenyl (S)%87 40-14081 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 56 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 739629 SW-846 SW-846 Dry Weight/Percent Moisture Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92638346001, 92638346002, 92638346003 Parameter Units Dup Result Max RPD QualifiersRPDResult 92638286001 3848542SAMPLE DUPLICATE: Percent Moisture %42.9 N262545.7 Parameter Units Dup Result Max RPD QualifiersRPDResult 92638357001 3848543SAMPLE DUPLICATE: Percent Moisture %27.3 N222527.9 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 57 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 739841 SW-846 SW-846 Dry Weight/Percent Moisture Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92638346004, 92638346005, 92638346006, 92638346007, 92638346008, 92638346009, 92638346010, 92638346011, 92638346012, 92638346013, 92638346014, 92638346015 Parameter Units Dup Result Max RPD QualifiersRPDResult 92637772001 3849453SAMPLE DUPLICATE: Percent Moisture %18.7 N242519.5 Parameter Units Dup Result Max RPD QualifiersRPDResult 92638444001 3849454SAMPLE DUPLICATE: Percent Moisture %68.7 N222569.8 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 58 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 741865 SW-846 SW-846 Dry Weight/Percent Moisture Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples:92638346016 Parameter Units Dup Result Max RPD QualifiersRPDResult 92638346016 3859289SAMPLE DUPLICATE: Percent Moisture %27.0 N202526.9 Parameter Units Dup Result Max RPD QualifiersRPDResult 92640311002 3859302SAMPLE DUPLICATE: Percent Moisture %26.1 N212525.7 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 59 of 69 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 1972323 SM 2540 G SM 2540G Total Solids 2540 G-2011 Laboratory:Pace National - Mt. Juliet Associated Lab Samples:92638346001 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK:R3871158-1 Associated Lab Samples:92638346001 Matrix:Solid AnalyzedMDL Total Solids %0.00300 12/12/22 14:38 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. R3871158-2LABORATORY CONTROL SAMPLE: LCSSpike Total Solids %50.050.0 100 85.0-115 Parameter Units Dup Result Max RPD QualifiersRPDResult L1565828-03 R3871158-3SAMPLE DUPLICATE: Total Solids %84.0 1.40 1082.8 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 60 of 69 #=QL# QUALIFIERS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS Result may be biased high due to carryover from previously analyzed sample.C8 Analysis conducted outside the EPA method holding time.H1 Extraction or preparation conducted outside EPA method holding time.H2 Sample was received or analysis requested beyond the recognized method holding time.H3 The recalculated concentration of the calibration standard(s) did not meet method acceptance criteria; this result should be considered an estimated value.IK Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.M1 The lab does not hold NELAC/TNI accreditation for this parameter but other accreditations/certifications may apply. A complete list of accreditations/certifications is available upon request.N2 Surrogate recovery outside laboratory control limits.S0 Surrogate recovery outside laboratory control limits due to matrix interferences (confirmed by similar results from sample re-analysis).S2 Surrogate recovery not evaluated against control limits due to sample dilution.S4 Surrogate recovery outside control limits due to matrix interferences (not confirmed by re-analysis).S5 The continuing calibration verification was above the method acceptance limit. Any detection for the analyte in the associated samples may have a high bias.v1 The continuing calibration verification was below the method acceptance limit. The analyte was not detected in the associated samples and the sensitivity of the instrument was verified with a reporting limit check standard.v2 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 61 of 69 #=QL# QUALIFIERS Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE ANALYTE QUALIFIERS The continuing calibration verification was below the method acceptance limit. Any detection for the analyte in the associated samples may have low bias.v3 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 62 of 69 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92638346004 740092 740434D-4 EPA 3546 EPA 8015C 92638346005 740092 740434D-5 EPA 3546 EPA 8015C 92638346007 740092 740434D-7 EPA 3546 EPA 8015C 92638346012 740092 740434PL-5 EPA 3546 EPA 8015C 92638346013 740092 740434PL-6 EPA 3546 EPA 8015C 92638346014 740092 740434PL-7 EPA 3546 EPA 8015C 92638346015 740092 740434PL-8 EPA 3546 EPA 8015C 92638346016 741187 741568PL-8 (RISK)MADEP EPH MADEP EPH 92638346001 1973216 1973216D-1 MADEPV MADEP VPH 92638346001 1973747 1973747D-1 MADEPV MADEP VPH 92638346016 1973216 1973216PL-8 (RISK)MADEPV MADEP VPH 92638346016 1973747 1973747PL-8 (RISK)MADEPV MADEP VPH 92638346001 739499 739529D-1 EPA 5030B EPA 8015C 92638346002 739300 739304D-2 EPA 5030B EPA 8015C 92638346003 739300 739304D-3 EPA 5030B EPA 8015C 92638346004 739300 739304D-4 EPA 5030B EPA 8015C 92638346005 739300 739304D-5 EPA 5030B EPA 8015C 92638346006 739300 739304D-6 EPA 5030B EPA 8015C 92638346007 739300 739304D-7 EPA 5030B EPA 8015C 92638346008 739300 739304PL-1 EPA 5030B EPA 8015C 92638346009 739300 739304PL-2 EPA 5030B EPA 8015C 92638346010 739300 739304PL-3 EPA 5030B EPA 8015C 92638346011 739300 739304PL-4 EPA 5030B EPA 8015C 92638346012 739300 739304PL-5 EPA 5030B EPA 8015C 92638346013 739300 739304PL-6 EPA 5030B EPA 8015C 92638346014 739300 739304PL-7 EPA 5030B EPA 8015C 92638346015 739499 739529PL-8 EPA 5030B EPA 8015C 92638346016 741034 741269PL-8 (RISK)EPA 3546 EPA 8270E 92638346001 741531 741564D-1 EPA 5035A/5030B EPA 8260D 92638346016 741169 741202PL-8 (RISK)EPA 5035A/5030B EPA 8260D 92638346001 739629D-1 SW-846 92638346002 739629D-2 SW-846 92638346003 739629D-3 SW-846 92638346004 739841D-4 SW-846 92638346005 739841D-5 SW-846 92638346006 739841D-6 SW-846 92638346007 739841D-7 SW-846 92638346008 739841PL-1 SW-846 92638346009 739841PL-2 SW-846 92638346010 739841PL-3 SW-846 92638346011 739841PL-4 SW-846 92638346012 739841PL-5 SW-846 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 63 of 69 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92638346 SPEEDWAY 7940 GUILFORD COLLEGE Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92638346013 739841PL-6 SW-846 92638346014 739841PL-7 SW-846 92638346015 739841PL-8 SW-846 92638346016 741865PL-8 (RISK)SW-846 92638346001 1972323 1972323D-1 SM 2540 G SM 2540G REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 12/29/2022 04:43 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 64 of 69 Page 65 of 69 Page 66 of 69 Page 67 of 69 Page 68 of 69 Page 69 of 69