HomeMy WebLinkAboutWA-92955_96655_CA_LAB_20211228The electronic signature above is the equivalent of a handwritten signature.
This report shall not be reproduced,except in its entirety,without the written approval of Pace Analytical Services,LLC.
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.)
106 Vantage Point Drive West Columbia,SC 29172
Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com
Report of Analysis
NCDEQ-DWM-UST Section
943 Washington SQ Mall
Washington,NC 27889
Attention:Jared Edwards
Project Name:Tighe Property
Lot Number:WL14026
Date Completed:12/28/2021
01/06/2022 10:52 PM
Approved and released by:
Project Manager II:Cathy S.Dover
Page 1 of 22
PACE ANALYTICAL SERVICES,LLC
SC DHEC No:32010001 NELAC No:E87653 NC DENR No:329 NC Field Parameters No:5639
Pace Analytical Services,LLC (formerly Shealy Environmetal Services,Inc.)
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax (803)791-9111 www.pacelabs.com
Case Narrative
NCDEQ-DWM-UST Section
Lot Number:WL14026
This Report of Analysis contains the analytical result(s)for the sample(s)listed on the Sample Summary
following this Case Narrative.The sample receiving date is documented in the header information
associated with each sample.All results listed in this report relate only to the samples that are contained
within this report.
Sample receipt,sample analysis,and data review have been performed in accordance with the most
current approved The NELAC Institute (TNI)standards,the Pace Analytical Services,LLC ("Pace")
Laboratory Quality Manual,standard operating procedures (SOPs),and Pace policies.Any exceptions to
the TNI standards,the Laboratory Quality Manual,SOPs or policies are qualified on the results page or
discussed below.
Pace is a TNI accredited laboratory;however,the following analyses are currently not listed on our TNI
scope of accreditation:
Biological Tissue:All,Non-Potable Water:SGT-HEM EPA 1664B,Silica EPA 200.7,Boron,Calcium,
Silicon,Strontium EPA 200.8,Bicarbonate,Carbonate,and Hydroxide Alkalinity SM 2320 B-2011,Fecal
Coliform SM 9221 C E-2006 &SM 9222D-2006,Strontium SW-846 6010D,VOC SM 6200 B-2011,
Drinking Water:VOC (excluding BTEX,MTBE,Naphthalene,&1,2-dichloroethane)EPA 524.2,Solid
Chemical Material:TOC Walkley-Black.
Where applicable,all soil sample results (including LOQ and DL if requested)are corrected for dry weight
unless flagged with a "W"qualifier.
TPH-GRO 8015C
Insufficient sample volume was provided to perform matrix spike/matrix spike duplicate (MS/MSD)for
analytical batch 25726.An LCS/LCSD was run in lieu of an MS/MSD.
Sample WL14026-003 (Trip)had an air bubble >6mm in the sample vial.
TPH-DRO 8015C
Insufficient sample volume was provided to perform matrix spike/matrix spike duplicate (MS/MSD)for
prep batch 25778.An LCS/LCSD was run in lieu of an MS/MSD.
Samples WL14026-001 (SS-1)and WL14026-002 (SS-2)required a 100x dilution which affected the
surrogate recovery.
If you have any questions regarding this report please contact the Pace Project Manager listed on the
cover page.
Page 2 of 22
PACE ANALYTICAL SERVICES, LLC
Sample Summary
NCDEQ-DWM-UST Section
Lot Number: WL14026
Project Name: Tighe Property
Project Number:
Sample Number Sample ID Matrix Date Sampled Date Received
001 12/10/2021 1031SS-1 Solid 12/14/2021
002 12/10/2021 1037SS-2 Solid 12/14/2021
003 12/10/2021TripAqueous 12/14/2021
(3 samples)
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 3 of 22
PACE ANALYTICAL SERVICES, LLC
Detection Summary
NCDEQ-DWM-UST Section
Lot Number: WL14026
Project Name: Tighe Property
Project Number:
Sample Sample ID Matrix Parameter Method Result Q Units Page
001 SS-1 Solid TPH-DRO 8015C 41000 Q mg/Kg 5
001 SS-1 Solid TPH-GRO 8015C 11000 mg/Kg 6
002 SS-2 Solid TPH-DRO 8015C 93000 Q mg/Kg 7
002 SS-2 Solid TPH-GRO 8015C 8100 mg/Kg 8
(4 detections)
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 4 of 22
TPH - DRO
Description:Matrix:
Date Received:
Client:Laboratory ID:
Date Sampled:
NCDEQ-DWM-UST Section
SS-1
WL14026-001
12/10/2021 1031
12/14/2021
Solid
% Solids:84.0 12/15/2021 0111Project Name: Tighe Property
Project Number:
Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch
1 3550C 8015C 100 12/28/2021 1323 NCM 12/15/2021 2249 25778
AnalyticalCAS
Parameter Number Method Result Q LOQ Units Run
TPH-DRO 8015C 41000 Q 1mg/Kg800
AcceptanceRun 1
Surrogate Q % Recovery Limits
o - Terphenyl N 242 55-120
LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range
P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria
H = Out of holding time
Q = Surrogate failure
L = LCS/LCSD failure
S = MS/MSD failureW = Reported on wet weight basis
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 5 of 22
TPH - GRO
Description:Matrix:
Date Received:
Client:Laboratory ID:
Date Sampled:
NCDEQ-DWM-UST Section
SS-1
WL14026-001
12/10/2021 1031
12/14/2021
Solid
% Solids:84.0 12/15/2021 0111Project Name: Tighe Property
Project Number:
Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch
1 5030B 8015C 10 12/15/2021 2005 ECB 25726
AnalyticalCAS
Parameter Number Method Result Q LOQ Units Run
TPH-GRO 8015C 11000 1mg/Kg220
AcceptanceRun 1
Surrogate Q % Recovery Limits
Bromofluorobenzene 93 23-179
LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range
P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria
H = Out of holding time
Q = Surrogate failure
L = LCS/LCSD failure
S = MS/MSD failureW = Reported on wet weight basis
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 6 of 22
TPH - DRO
Description:Matrix:
Date Received:
Client:Laboratory ID:
Date Sampled:
NCDEQ-DWM-UST Section
SS-2
WL14026-002
12/10/2021 1037
12/14/2021
Solid
% Solids:70.1 12/15/2021 0111Project Name: Tighe Property
Project Number:
Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch
1 3550C 8015C 100 12/28/2021 1332 NCM 12/15/2021 2249 25778
AnalyticalCAS
Parameter Number Method Result Q LOQ Units Run
TPH-DRO 8015C 93000 Q 1mg/Kg950
AcceptanceRun 1
Surrogate Q % Recovery Limits
o - Terphenyl N 271 55-120
LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range
P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria
H = Out of holding time
Q = Surrogate failure
L = LCS/LCSD failure
S = MS/MSD failureW = Reported on wet weight basis
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 7 of 22
TPH - GRO
Description:Matrix:
Date Received:
Client:Laboratory ID:
Date Sampled:
NCDEQ-DWM-UST Section
SS-2
WL14026-002
12/10/2021 1037
12/14/2021
Solid
% Solids:70.1 12/15/2021 0111Project Name: Tighe Property
Project Number:
Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch
1 5030B 8015C 5 12/15/2021 2030 ECB 25726
AnalyticalCAS
Parameter Number Method Result Q LOQ Units Run
TPH-GRO 8015C 8100 1mg/Kg190
AcceptanceRun 1
Surrogate Q % Recovery Limits
Bromofluorobenzene 78 23-179
LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range
P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria
H = Out of holding time
Q = Surrogate failure
L = LCS/LCSD failure
S = MS/MSD failureW = Reported on wet weight basis
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 8 of 22
TPH - GRO
Description:Matrix:
Date Received:
Client:Laboratory ID:
Date Sampled:
NCDEQ-DWM-UST Section
Trip
WL14026-003
12/10/2021
12/14/2021
Aqueous
Project Name: Tighe Property
Project Number:
Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch
1 5030B 8015C 1 12/21/2021 1732 ECB 26371
AnalyticalCAS
Parameter Number Method Result Q LOQ Units Run
TPH-GRO 8015C ND 1mg/L0.10
AcceptanceRun 1
Surrogate Q % Recovery Limits
Bromofluorobenzene 113 70-130
LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range
P = The RPD between two GC columns exceeds 40%ND = Not detected at or above the LOQ N = Recovery is out of criteria
H = Out of holding time
Q = Surrogate failure
L = LCS/LCSD failure
S = MS/MSD failureW = Reported on wet weight basis
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 9 of 22
QC Summary
QC Data for Lot Number: WL14026
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 10 of 22
TPH - DRO - MB
Batch:Prep Method:
Prep Date:
Sample ID:WQ25778-001
25778 3550C
12/15/2021 2249Analytical Method:8015C
Matrix:Solid
Parameter Result Q LOQ Units Analysis DateDil
TPH-DRO ND 12/23/2021 11406.7 mg/Kg1
Surrogate Q % Rec
Acceptance
Limit
o - Terphenyl 95 55-120
Note:Calculations are performed before rounding to avoid round-off errors in calculated results
LOQ = Limit of Quantitation ND = Not detected at or above the LOQ N = Recovery is out of criteria
P = The RPD between two GC columns exceeds 40%
+ = RPD is out of criteria* = RSD is out of criteria
QC Data for Lot Number: WL14026
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 11 of 22
TPH - DRO - LCS
Batch:Prep Method:
Prep Date:
Sample ID:WQ25778-002
25778 3550C
12/15/2021 2249Analytical Method:8015C
Matrix:Solid
Parameter
Result
Q % Rec
Spike
Amount
Analysis Date
%Rec
LimitDil(mg/Kg)(mg/Kg)
TPH-DRO 88 12/23/2021 11501068370-1301
Surrogate Q % Rec
Acceptance
Limit
o - Terphenyl 99 55-120
Note:Calculations are performed before rounding to avoid round-off errors in calculated results
LOQ = Limit of Quantitation ND = Not detected at or above the LOQ N = Recovery is out of criteria
P = The RPD between two GC columns exceeds 40%
+ = RPD is out of criteria* = RSD is out of criteria
QC Data for Lot Number: WL14026
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 12 of 22
TPH - DRO - LCSD
Batch:Prep Method:
Prep Date:
Sample ID:WQ25778-003
25778 3550C
12/15/2021 2249Analytical Method:8015C
Matrix:Solid
Parameter
Result
Q % Rec
Spike
Amount
Analysis Date% RPD
%Rec
Limit
% RPD
LimitDil(mg/Kg)(mg/Kg)
TPH-DRO 87 12/23/2021 11591058370-1300.82 201
Surrogate Q % Rec
Acceptance
Limit
o - Terphenyl 94 55-120
Note:Calculations are performed before rounding to avoid round-off errors in calculated results
LOQ = Limit of Quantitation ND = Not detected at or above the LOQ N = Recovery is out of criteria
P = The RPD between two GC columns exceeds 40%
+ = RPD is out of criteria* = RSD is out of criteria
QC Data for Lot Number: WL14026
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 13 of 22
TPH - GRO - MB
Batch:Prep Method:
Sample ID:WQ25726-001
25726 5030B
Analytical Method:8015C
Matrix:Solid
Parameter Result Q LOQ Units Analysis DateDil
TPH-GRO ND 12/15/2021 16085.0 mg/Kg1
Surrogate Q % Rec
Acceptance
Limit
Bromofluorobenzene 123 23-179
Note:Calculations are performed before rounding to avoid round-off errors in calculated results
LOQ = Limit of Quantitation ND = Not detected at or above the LOQ N = Recovery is out of criteria
P = The RPD between two GC columns exceeds 40%
+ = RPD is out of criteria* = RSD is out of criteria
QC Data for Lot Number: WL14026
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 14 of 22
TPH - GRO - LCS
Batch:Prep Method:
Sample ID:WQ25726-002
25726 5030B
Analytical Method:8015C
Matrix:Solid
Parameter
Result
Q % Rec
Spike
Amount
Analysis Date
%Rec
LimitDil(mg/Kg)(mg/Kg)
TPH-GRO 59 12/15/2021 15181185070-1301
Surrogate Q % Rec
Acceptance
Limit
Bromofluorobenzene 116 23-179
Note:Calculations are performed before rounding to avoid round-off errors in calculated results
LOQ = Limit of Quantitation ND = Not detected at or above the LOQ N = Recovery is out of criteria
P = The RPD between two GC columns exceeds 40%
+ = RPD is out of criteria* = RSD is out of criteria
QC Data for Lot Number: WL14026
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 15 of 22
TPH - GRO - LCSD
Batch:Prep Method:
Sample ID:WQ25726-003
25726 5030B
Analytical Method:8015C
Matrix:Solid
Parameter
Result
Q % Rec
Spike
Amount
Analysis Date% RPD
%Rec
Limit
% RPD
LimitDil(mg/Kg)(mg/Kg)
TPH-GRO 59 12/15/2021 15431175070-1300.51 201
Surrogate Q % Rec
Acceptance
Limit
Bromofluorobenzene 112 23-179
Note:Calculations are performed before rounding to avoid round-off errors in calculated results
LOQ = Limit of Quantitation ND = Not detected at or above the LOQ N = Recovery is out of criteria
P = The RPD between two GC columns exceeds 40%
+ = RPD is out of criteria* = RSD is out of criteria
QC Data for Lot Number: WL14026
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 16 of 22
TPH - GRO - MB
Batch:Prep Method:
Sample ID:WQ26371-001
26371 5030B
Analytical Method:8015C
Matrix:Aqueous
Parameter Result Q LOQ Units Analysis DateDil
TPH-GRO ND 12/21/2021 15040.10 mg/L1
Surrogate Q % Rec
Acceptance
Limit
Bromofluorobenzene 111 70-130
Note:Calculations are performed before rounding to avoid round-off errors in calculated results
LOQ = Limit of Quantitation ND = Not detected at or above the LOQ N = Recovery is out of criteria
P = The RPD between two GC columns exceeds 40%
+ = RPD is out of criteria* = RSD is out of criteria
QC Data for Lot Number: WL14026
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 17 of 22
TPH - GRO - LCS
Batch:Prep Method:
Sample ID:WQ26371-002
26371 5030B
Analytical Method:8015C
Matrix:Aqueous
Parameter
Result
Q % Rec
Spike
Amount
Analysis Date
%Rec
LimitDil(mg/L)(mg/L)
TPH-GRO 1.2 12/21/2021 14141151.0 70-1301
Surrogate Q % Rec
Acceptance
Limit
Bromofluorobenzene 102 70-130
Note:Calculations are performed before rounding to avoid round-off errors in calculated results
LOQ = Limit of Quantitation ND = Not detected at or above the LOQ N = Recovery is out of criteria
P = The RPD between two GC columns exceeds 40%
+ = RPD is out of criteria* = RSD is out of criteria
QC Data for Lot Number: WL14026
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 18 of 22
TPH - GRO - LCSD
Batch:Prep Method:
Sample ID:WQ26371-003
26371 5030B
Analytical Method:8015C
Matrix:Aqueous
Parameter
Result
Q % Rec
Spike
Amount
Analysis Date% RPD
%Rec
Limit
% RPD
LimitDil(mg/L)(mg/L)
TPH-GRO 1.1 12/21/2021 14391091.0 70-1305.4 201
Surrogate Q % Rec
Acceptance
Limit
Bromofluorobenzene 98 70-130
Note:Calculations are performed before rounding to avoid round-off errors in calculated results
LOQ = Limit of Quantitation ND = Not detected at or above the LOQ N = Recovery is out of criteria
P = The RPD between two GC columns exceeds 40%
+ = RPD is out of criteria* = RSD is out of criteria
QC Data for Lot Number: WL14026
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 19 of 22
Chain of Custody
and
Miscellaneous Documents
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 20 of 22
PACE ANALYTICAL SERVICES, LLC
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 21 of 22
PACE ANALYTICAL SERVICES, LLC
106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com
Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.)
Page 22 of 22