HomeMy WebLinkAboutWA-27528_38681_CA_RPTS_20190821_LSA2
Speedway LLC
Speedway Office
500 Speedway Drive
Enon, OH 45323
Telephone 937-864-3000
August 21, 2019
Delivered via electronic mail to anna.edwards@ncdenr.gov
Ms. Anna Edwards
North Carolina Department of Environmental Quality
Washington Regional Office
Division of Waste Management - UST Section
943 Washington Square Mall
Washington, North Carolina 27889
Re: Phase II Limited Site Assessment Report
Speedway No. 7956
107 South Wilson Street
Fremont, Wayne County, North Carolina
NCDEQ Facility ID 0-035993
Dear Ms. Edwards:
Speedway LLC (Speedway) is pleased to provide the attached Phase II Limited Site Assessment
(LSA) Report for the referenced site. The services outlined in this report were performed by our
consultant, ATC Associates of North Carolina, P.C. (ATC), as directed by the North Carolina
Department of Environmental Quality (NCDEQ), based on analytical soil and groundwater
concentrations being detected greater than their respective Soil-to-Groundwater Maximum Soil
Contaminant Concentrations (MSCC) and 2L Standards in soil and groundwater obtained during the
LSA activities.
On July 8, 2019, three, two-inch diameter monitoring wells (identified as MW-01, MW-02, and MW-03)
were installed at the site. Concentrations of benzene, toluene, ethylbenzene, total xylenes,
naphthalene, C5-C8 Aliphatics, C9-C12 Aliphatics, C9-C10 Aromatics, ethylene dibromide (EDB), and
lead were detected greater than their respective 2L Standards in the samples collected from the site
monitoring wells. As a result, a Comprehensive Site Assessment (CSA) is recommended to be
completed at the site.
If you have any questions or require additional information, please contact me at 919-516-8069 or
by email at cachiara@speedway.com.
Sincerely,
Speedway LLC
Charles A. Chiara
Environmental Representative
Attachment
cc: ATC Associates of North Carolina, P.C., 2725 East Millbrook Road, Suite 121, Raleigh, North Carolina 27604
Phase II Limited Site Assessment Report
Prepared for:
Speedway LLC
August 21, 2019
Speedway No. 7956
107 South Wilson Street
Fremont, Wayne County, North Carolina
NCDEQ Incident No. 38681
ATC Project No. SWDP795604
NCDEQ Risk Classification - Pending
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Document Information
Prepared for Speedway LLC
Project Name Speedway No. 7956
File Reference SW 79567_August 2019_LSA II Report
Job Reference SWDP795604
Date August 21, 2019
Contact Information
ATC Associates of North Carolina, P.C.
2725 East Millbrook Road, Suite 121
Raleigh, North Carolina 27604
Telephone: 919.871.0999
www.atcgs.com
Document Control
Version Date Author Author
Initials
Reviewer Reviewer
Initials
Draft 7-31-19 D.T. Hurdle DTH Bob Bolton BB
Final 8-21-19 D.T. Hurdle DTH Bob Bolton BB
Bob Bolton Donald T. Hurdle, P.G.
Senior Project Manager Project Manager
for ATC Group Services LLC for ATC Group Services LLC
Direct Line +1 803.223.0793 Direct Line +1 757.467.2100
Email: bob.bolton@atcgs.com Email: donald.hurdle@atcgs.com
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Site Information
Site Name: Speedway No. 7956
Site Address: 107 South Wilson Street
Fremont, Wayne County, North Carolina
Facility I.D.: 0-035993 UST Incident Number (if known): Unknown
Latitude: 35.543453 Longitude: -77.975753
Source: Google Earth
UST Owner: Speedway LLC UST Operator: Speedway LLC
Address: 500 Speedway Drive Address: 500 Speedway Drive
Enon, Ohio 45323 Enon, Ohio 45323
Telephone (919) 516-8069 Telephone (919) 516-8069
Property Property
Owner: Speedway LLC Occupant: Speedway LLC
Address: 500 Speedway Drive Address: 500 Speedway Drive
Enon, Ohio 45323 Enon, Ohio 45323
Telephone (919) 516-8069 Telephone (919) 516-8069
Consultant: ATC Associates of North Carolina, P.C.
Address: 2725 East Millbrook Road, Suite 121
Raleigh, North Carolina 27604
Telephone (919) 871-0999
Analytical
Laboratory: Pace Analytical State Certification No. ENV375/DW21704/BI0041
Address: 12065 Lebanon Road, Mt. Juliet, Tennessee 37122
Telephone (615) 758-5858
Release Information
Date Discovered: June 8, 2017
Estimated Quantity
Of Release: Unknown
Cause of Release: Failed spill bucket associated with the premium unleaded UST.
UST Information: One 12,000-gallon premium unleaded gasoline UST.
I, Donald T. Hurdle, a Professional Engineer/Licensed Geologist (circle one) for ATC Associates of North Carolina.
P.C., do certify that the information contained in this report is correct and accurate to the best of my knowledge.
ATC Associates of North Carolina. P.C. is licensed to practice geology/engineering (circle one or both) in North
Carolina. The certification number issued by the North Carolina Board for Licensing of Geologists is C-274. The
certification number issued by the North Carolina Board of Examiners for Engineers and Surveyors is C-1598.
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Executive Summary
ATC Associates of North Carolina, P.C., on behalf of Speedway LLC (Speedway), conducted Phase II Limited Site
Assessment (LSA) activities at the Speedway No. 7956, as directed by the North Carolina Department of
Environmental Quality (NCDEQ), based on concentrations of benzene, ethylbenzene, total xylenes, naphthalene,
lead, C5-C8 Aliphatics, and C9-C12 Aliphatics being detected greater than their respective 2L Standards in the
groundwater sample collected during the site check addendum and initial LSA activities.
On July 8, 2019, three, two-inch diameter monitoring wells (identified as MW-01, MW-02, and MW-03) were
installed at the site. Concentrations of benzene, toluene, ethylbenzene, total xylenes, naphthalene, C5-C8
Aliphatics, C9-C12 Aliphatics, C9-C10 Aromatics, ethylene dibromide (EDB), and lead were detected greater than
their respective 2L Standards in the samples collected from the site monitoring wells. As a result, ATC recommends
a Comprehensive Site Assessment (CSA) be completed at the site.
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Table of Contents
Site Information iii
Executive Summary iv
1 Introduction 7
1.1 UST Owner and Operator Information 7
1.2 UST Information 7
1.3 Site Status 7
1.4 AST Information 7
1.5 Site History 7
2 Risk Characterization 9
3 Receptor Information 10
3.1 Water Supply Wells 10
3.2 Public Water Supplies 10
3.3 Surface Water 10
3.4 Wellhead Protection Areas 10
3.5 Deep Aquifers in the Coastal Plain 10
3.6 Subsurface Structures 11
3.7 Land Use 11
4 Subsurface Investigation 12
4.1 Site Geology 12
4.2 Soil Boring and Sample Collection 12
4.3 Soil Analytical Results 12
4.4 Monitoring Well Installation 12
4.5 Groundwater Sample Collection and Analysis 12
4.6 Groundwater Analytical Results 13
4.7 Site Survey 13
4.8 Site Hydrogeology 13
5 Findings and Conclusions 14
6 Recommendations 15
7 Report Limitations 16
Tables
TABLE 1 UST Owner/Operator and Responsible Party Information
TABLE 2 Property Owners within 500 feet
TABLE 3 Summary of Soil Analytical Results
TABLE 4 Summary of Groundwater Analytical Results
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Figures
FIGURE 1 Site Location Map
FIGURE 2 Site Map
FIGURE 3 Petroleum Constituents in Soil Map (July 8, 2019)
FIGURE 4 Petroleum Constituents in Groundwater Map (July 16, 2019)
FIGURE 5 Groundwater Elevation Contour Map
Appendices
APPENDIX A Limited Site Assessment Report Review Letter
APPENDIX B NCDEQ Risk Classification and Land Use Form
APPENDIX C Water Supply Well Mailing Forms and Water Supply Well location Map
APPENDIX D Soil Boring Logs and NCDEQ Well Construction Records
APPENDIX E Laboratory Analytical Results – Soil and Groundwater
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
1 Introduction
Speedway LLC (Speedway) contracted ATC Associates of North Carolina, P.C. (ATC) to perform Phase II Limited
Site Assessment (LSA) activities at the Speedway No. 7956 facility located at 107 South Wilson Street, Fremont
Wayne County, North Carolina. Figure 1 shows the location of the site on part of a United States Geological
Survey (USGS) topographic map. The site currently operates as a Speedway convenience store with retail
gasoline, diesel, and kerosene sales. Figure 2 depicts the site layout including the location of relevant site
features. The Phase II LSA activities described herein were initiated based on concentrations of benzene,
ethylbenzene, total xylenes, naphthalene, lead, C5-C8 Aliphatics, and C9-C12 Aliphatics greater than their
respective 2L Standards in the onsite temporary monitoring well completed during the site check addendum
activities. On April 10, 2019, Speedway submitted the LSA Report to the North Carolina Department of
Environmental Quality (NCDEQ) that documented the installation and sampling of temporary monitoring well SB-
02. On May 8, 2019, the NCDEQ issued a LSA Report Review Letter stating that three additional monitoring wells
should be installed at the site to obtain up-gradient and down-gradient groundwater analytical data and monitoring
location points that will establish groundwater flow at the site. A copy of the LSA review letter requesting the
Phase II LSA activities is provided in Appendix A.
1.1 UST Owner and Operator Information
Two underground storage tanks (USTs) are currently in operation at the referenced facility. The USTs and their
appurtenances are owned and operated by Speedway LLC of Enon, Ohio. Information regarding each of the tanks
is provided below. UST system owner/operator information is provided in Table 1.
1.2 UST Information
UST ID PRODUCT CAPACITY
(gals.) MATERIALS INSTALLATION
DATE
UST
STATUS
RELEASE
ASSOCIATED
(Yes/No)
1
Gasoline
(Regular) 12,000
Fiberglass
Clad
Singlewall
Steel
05-01-1999 Active No
2 Gasoline
(Premium) 12,000
Fiberglass
Clad
Singlewall
Steel
05-01-1999 Active Yes
(Suspected)
1.3 Site Status
Presently, the site is an active convenience store with retail fuel sales. The USTs and their appurtenances are in
operation at the referenced facility. Surface cover at the site consists of asphalt and concrete.
1.4 AST Information
No above ground storage tanks (ASTs) were observed on the site.
1.5 Site History
On June 9, 2017, Speedway submitted NCDEQ Form UST-17A, which documented a suspected release at the
above referenced site due to the premium unleaded UST spill bucket failing a hydrostatic test on June 9, 2017.
On July 7, 2017, Speedway submitted NCDEQ Form UST-17B that included the failed hydrostatic test results. On
July 24, 2017, ATC used a hand auger to complete a soil boring (identified as SB-01) to 13 feet below grade near
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
the spill bucket end of the premium unleaded tank. The soil samples were placed in laboratory-supplied containers,
entered into chain-of-custody control, placed on ice, and shipped via FedEx to ESC Lab Sciences (ESC) [12065
Lebanon Road, Mt. Juliet, Tennessee 37122, North Carolina Laboratory Certification Number
ENV375/DW21704/BI0041, (615) 758-5858] for benzene, toluene, ethylbenzene, total xylenes (BTEX), methyl
tert-butyl ether (MTBE), and naphthalene analysis by Environmental Protection Agency (EPA) Method 6200B, and
Massachusetts Department of Environmental Protection (MADEP) Method for volatile petroleum hydrocarbons
(VPH). Laboratory analytical results detected concentrations of xylenes, naphthalene, and C5-C8 Aliphatics
greater than their respective Soil-to-Groundwater Maximum Contaminant Concentrations (MSCC).
NCDEQ Form UST-61 was submitted to the NCDEQ on August 18, 2017, documenting the advancement of the
soil boring and soil sampling activities conducted on July 24, 2017. Laboratory analytical results indicated
concentrations of xylene, naphthalene and C5-C8 Aliphatics exceeded their respective Soil-to-Groundwater
MSCC in the soil sample collected from soil boring SB-01. On July 13, 2018, the NCDEQ directed Speedway to
complete the Site Check Addendum that included groundwater sample collection in the area of boring SB-01.
On August 6, 2018, ATC oversaw ARM Environmental (ARM) install an additional boring, identified as SB-02,
adjacent to the boring SB-01 to collect a groundwater sample. ARM installed boring SB-02 using direct push
technology to a depth of 15 feet below land surface (bls). A temporary well was constructed of one-inch diameter
schedule-40 polyvinyl chloride (PVC) riser with 10 feet of 0.010-inch slotted screen. The borehole annulus was
backfilled with No. 2 sand filter pack. Using a water level indicator, ATC measured the depth to groundwater to
be 6.09 feet bls in boring SB-02. Subsequently, a groundwater sample was collected from the temporary
monitoring well; placed in laboratory-supplied, preserved containers; entered into chain-of-custody; placed on ice;
and shipped via FedEx to ESC for analysis of volatile organics by EPA Method 6200B, MADEP VPH analysis,
lead analysis by EPA Method 6010D, and ethylene dibromide (EDB) analysis by EPA Method 8011. The well
casing and screen were removed from the ground once the groundwater samples were obtained.
Laboratory analytical results detected concentrations of benzene, ethylbenzene, total xylenes, naphthalene, lead,
C5-C8 Aliphatics, and C9-C12 Aliphatics greater than their respective 2L Standards in sample SB-02; however, no
analytes were detected greater than their respective gross contaminant levels (GCLs). Based on these results,
the NCDEQ issued a Notice of Reporting Requirements (NORR) requesting LSA activities be conducted.
ATC completed LSA activities at the site and recommended further evaluation based on the groundwater
concentrations of benzene, toluene, total xylenes, naphthalene, lead, C5-C8 Aliphatics, and C9-C12 Aliphatics being
greater than their respective 2L Standards. ATC recommended the installation of three monitoring wells to determine
the direction of groundwater flow and determine the horizontal extent of the chemicals of concern.
The NCDEQ concurred with ATC’s findings and requested a Limited Site Assessment Phase II be performed at the
site.
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
2 Risk Characterization
In accordance with 15A NCAC 2L .0115, a completed Limited Site Assessment Risk Classification and Land Use
Form provided by the NCDEQ is included in Appendix B. Answers and explanations included on the form are
based on information obtained by ATC during the LSA and Phase II LSA activities.
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
3 Receptor Information
3.1 Water Supply Wells
ATC performed a survey to identify water supply wells within 1,500 feet of the site by visually observing the site
and surrounding areas. Water supply well forms were sent to property owners within 1,500 feet of the source area
where suspected well structures were observed and to all owners within 500 feet of the source. One water well
was confirmed on property approximately 485 feet west from the site at 101 North Vance Street. According to the
owner of the property, Mr. Walter Marm, the well is used for irrigation and to fill a swimming pool. Another well
was confirmed located at 201 Pine Street, approximately 1,090 feet east from the site. According to the owner,
Mr. Fred Johnson, the well is used to fill a small fish pond and for irrigation. Neither of the wells identified is used
for potable purposes. Based on the completed and/or returned water supply well surveys, there are no other water
supply wells located within 1,500 feet of the site. The water supply well map is included in Appendix C, and the
property owners are summarized in Table 2.
3.2 Public Water Supplies
ATC contacted Mr. Josh Pulley of the Fremont Water and Sewer Department who confirmed the Town of Fremont is
the primary local water provider. The Town has no wells but rather purchases municipal drinking water from the
Wayne County Water District. The public water source is a series of wells throughout Wayne County. The closest
deep well maintained by the district is approximately four miles west of the site. The well is further discussed in
Section 3.4.
3.3 Surface Water
ATC reviewed a USGS 7.5-Minute Quadrangle Topographic Map, which is included as Figure 1, to identify surface
water bodies in the site vicinity. In addition, ATC conducted a visual reconnaissance for surface water bodies in
the area. An intermittent stream, which flows to Great Swamp, was observed approximately 0.6 mile northwest of
the site; another intermittent stream, which flows to Nahunta Swamp, was observed approximately 0.64 mile south
of the site; and another intermittent stream, which flows to Aycock Swamp, was observed approximately 0.8 mile
east of the site.
3.4 Wellhead Protection Areas
According the Division of Water Quality Wellhead Protection Website, the site is not located within a wellhead
protection program area. However, a wellhead protection area is located approximately 3.8 miles west from the
site. The wellhead protection area is due to the presence of Wayne Water District System water well located
approximately four miles west from the site.
3.5 Deep Aquifers in the Coastal Plain
The risk classification criteria specified in Title 15A NCAC 2L .0115(d) requires an evaluation for the presence of
unconfined or semi-confined deep aquifers in the Coastal Plain Physiographic Region which may be used as a
source of drinking water. The site is located within the Inner Coastal Plain. Information concerning aquifers in the
area is summarized below. Additional information regarding the site geology and hydrogeology is included in
Section 4.0.
As part of the LSA, ATC reviewed a hydrogeological cross-section obtained from the on-line hydrogeologic
framework database maintained by the NCDEQ Division of Water Resources. Based on the hydrogeological
cross-section for the region of the site, the surficial aquifer in the site vicinity extends to a depth of approximately
50 feet bls; the Yorktown confining unit extends to approximately 52 feet bls; the Yorktown Aquifer extends
approximately 56 feet bls; the Black Creek confining unit extends to 57 feet bls; the Black Creek Aquifer extends
to 61 feet bls; the Upper Cape Fear confining unit extends to approximately 70 feet bgs; and the Upper Cape Fear
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
aquifer extends to approximately 93 feet bls. A copy of the hydrogeological cross-section is included in Appendix
C.
3.6 Subsurface Structures
Prior to drilling activities, One-Call of North Carolina, the public utility locating service, and a private utility locating
company were contacted to locate underground utilities at the site. Underground utilities (water, electric, fiber-
optic, sewer, telephone) were located on-site; however, the utilities did not intersect the water table.
3.7 Land Use
The subject site is located in the Town of Fremont, Wayne County, North Carolina. The site is accessible from South
Wilson Street from the southeast and East Wayne Street from the southwest. The site currently operates as a
Speedway convenience store with retail gasoline sales. A Land Use Classification Form is included in Appendix
B. The properties surrounding the subject facility are zoned GB (General Business) and R-10 (Residential Single
Family). Residences and commercial retail properties characterize the surrounding area.
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
4 Subsurface Investigation
4.1 Site Geology
According to the Geologic Map of North Carolina (1985) produced by Philip Brown, et al, the referenced site is
located within the Coastal Plain Physiographic Region of North Carolina. More specifically, the site is underlain
by the Yorktown Formation: fossiliferous clay with varying amounts of fine-grained sand, bluish gray, shell material
commonly concentrated in lenses; mainly in area north of the Neuse River. Based on observations made during
soil boring activities, the residual soil at the site consists mainly of orange-tan-brown to gray sandy clays.
4.2 Soil Boring and Sample Collection
ATC contracted Taylor Wiseman & Taylor (TWT) and ARM Environmental (ARM) to complete private utility locates,
air knifing (soft-dig technology), and soil boring/monitoring well installation activities at the site. On July 8 through
9, 2019, three, two-inch diameter monitoring well (identified as MW-01, MW-02, and MW-03) were installed at the
site. The location of monitoring wells is shown on Figure 2.
Prior to breaking ground, the area was investigated for potential underground utilities using ground penetrating
radar (gpr) and then cleared to a depth of six feet bls using air knifing (soft-dig) technology. After clearing the well
location, ARM conducted the soil boring using a hollow stem-auger (HSA) drill rig to advance the borings to a
depth of 13 feet bls. Soil from the borings was examined and screened for volatile petroleum hydrocarbons using
a photo-ionization detector (PID). The boring logs, along with the NCDEQ Well Construction Records, detailing
soil descriptions and PID readings are included in Appendix D.
The soil samples were placed in laboratory-supplied containers, entered into chain-of-custody control, placed on
ice, and shipped via FedEx to Pace for BTEX, MTBE, naphthalene, and di-isopropyl ether analysis by EPA Method
8260B, and MADEP VPH analysis.
4.3 Soil Analytical Results
Results of the laboratory analysis of the soil samples collected during the site check are summarized in Table 3
and shown on Figure 3. The following summary of findings is based on the laboratory analysis of the soil samples
collected on July 8, 2019:
Concentrations of benzene were detected greater than the respective Soil-to-Groundwater MSCC in the
soil collected from sample MW-01.
A copy of the laboratory analytical report and chain-of-custody documentation is included in Appendix E.
4.4 Monitoring Well Installation
The borings for monitoring wells MW-01, MW-02, and MW-03 were completed as a two-inch wells that were
grouted in place at a depth of 13 feet bls. The monitoring wells were each installed with 10 feet of 0.010 slotted
polyvinyl-chloride (PVC) well screen. The annular spaces within the borings were filled with pre-washed silica
sand, and a bentonite seal was placed above the sand. The remainder of the boring annulus were filled with grout.
The monitoring wells were finished with an eight-inch diameter well vault and a two by two foot concrete pad.
Investigatory derived waste (IDW) generated during the monitoring well installation activities was containerized in
five, properly labelled and sealed, DOT approved, steel 55-gallon drums. On July 24, 2019, the drums containing
the well installation soils and well development water were transported under non-hazardous waste manifest by
Chemviron Midwest Inc. for proper disposal.
4.5 Groundwater Sample Collection and Analysis
On July 16, 2019, groundwater samples were collected from monitoring wells MW-01, MW-02, and MW-03. The
groundwater samples were collected in laboratory-supplied containers, entered into chain-of-custody control,
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
placed on ice, and shipped via FedEx to Pace for BTEX, MTBE, naphthalene, and isopropyl ether (IPE) analysis
by EPA Method 6200B; 1,2-dibromoethane (EDB) analysis by EPA Method 504.1; lead by EPA Method 6010D;
and MADEP VPH analysis.
4.6 Groundwater Analytical Results
Results for laboratory analysis of the groundwater samples collected from monitoring wells MW-01, MW-02, and
MW-03 are summarized in Table 4 and are presented in Figure 4. The following summary of findings is based
on the laboratory analysis of the groundwater samples collected on July 16, 2019:
Concentrations of benzene, toluene, ethylbenzene, total xylenes, naphthalene, and petroleum
constituents as VPH were detected greater than their respective 2L Standards in monitoring wells MW-
01, MW-02, and MW-03;
Concentrations of EDB were detected greater than its 2L Standard in the groundwater samples from
monitoring wells MW-01 and MW-03;
Concentrations of lead were detected greater than its 2L Standard in the groundwater samples from
monitoring wells MW-01 and MW-02;
Concentrations of some of the chemicals of concern were detected greater than its 10 times 2L Standard in
groundwater samples collected from each of the monitoring wells; and
Concentrations of petroleum constituents were not detected greater than their respective GCLs in the
groundwater samples collected from the site monitoring well network.
A copy of the laboratory analytical report and chain-of-custody documentation is included in Appendix E.
4.7 Site Survey
On July 30, 2019, following the well installations, ATC remobilized to the site to conduct a top-of-casing (TOC) site
survey on the newly installed monitoring wells. A copy of the potentiometric surface map is included as Figure 5
4.8 Site Hydrogeology
On July 16, 2019, gauging of the site monitoring well network was performed using an oil/water interface probe
prior to sampling. Depth-to groundwater in site monitoring wells MW-01 through MW-03 ranged from 4.56 feet to
6.04 feet bls. Data from the July 16, 2019, gauging event was used to create a groundwater elevation contour
map presented as Figure 5. Free product was not observed in the site wells. Based on elevation data obtained
on July 9, 2019, groundwater flow appears to be generally towards the north.
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
5 Findings and Conclusions
Based on data collected during the recent Phase II activities, the following conclusions are made:
On July 8 through 9, 2019, three, two-inch diameter monitoring wells (identified as MW-01, MW-02, and
MW-03) were installed at the site;
Free product was not detected during the Phase II LSA activities;
Concentrations of benzene, toluene, ethylbenzene, total xylenes, naphthalene, and petroleum
constituents as VPH were detected greater than their respective 2L Standards in monitoring wells MW-
01, MW-02, and MW-03;
Concentrations of EDB were detected greater than its 2L Standard in the groundwater samples from
monitoring wells MW-01 and MW-03;
Concentrations of lead were detected greater than its 2L Standard in the groundwater samples from
monitoring wells MW-01 and MW-02;
Concentrations of some of the chemicals of concern were detected greater than its 10 times 2L Standard in
groundwater samples collected from each of the monitoring wells; and
Concentrations of petroleum constituents were not detected greater than their respective GCLs in the
groundwater samples collected from the site monitoring well network.
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
6 Recommendations
Based on the groundwater concentrations of benzene, toluene, ethylbenzene, total xylenes, naphthalene, C5-C8
Aliphatics, C9-C12 Aliphatics, C9-C10 Aromatics, EDB, and lead being detected greater than their respective 2L
Standards in the samples collected from the site monitoring wells, ATC recommends a Comprehensive Site
Assessment (CSA) be completed at the site.
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
7 Report Limitations
This investigation is intended to be a non-biased assessment of on-site environmental conditions proximate to the
location of the former and/or current UST system. Subsurface investigative and remedial methodologies were
performed in general accordance with applicable state and federal regulatory requirements. The information
presented in this report is based upon site-specific observations, generally accepted geological and environmental
consulting practices, and analytical results for environmental samples collected at the time the field investigation
was performed. The data presented in this report are believed to represent subsurface conditions at the facility;
however, data may not be completely representative of subsurface conditions at every location. ATC assumes no
liability arising from environmental impact to, or from, the site, regardless of the date of impact occurrence or
findings.
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Speedway No. 7956
TABLES
UST ID Number 1, 2 Facility ID Number 0-035993
City State Zip Telephone Number
Enon OH 45323 919-516-8069
City State Zip Telephone Number
Enon OH 45323 919-516-8069
TABLE 1
UST OWNER/OPERATOR AND OTHER RESPONSIBLE PARTY INFORMATION
SPEEDWAY NO. 7956
107 SOUTH WILSON STREET
FREMONT, WAYNE COUNTY, NORTH CAROLINA
ATC GROUP SERVICES OF NORTH CAROLINA, P.C. PROJECT NO. SWDP795603
Name of Operator Dates of Operation (MM/DD/YY to MM/DD/YY)
Speedway LLC 11-20-2015 to Current
Street Address
500 Speedway Drive
Name of Owner Dates of Operation
Speedway LLC 11-20-2015 to Current
500 Speedway Drive
Trade Family, LLC
PO Box 3435
Greenville, NC 27836
Cammie Odeh
4960 NC HWY 13 South
Goldsboro, NC 27530
Jason D. Capps
PO Box 173
Fremont, NC 27830
North Carolina Tel & Tel Co.
1825 Sunset Avenue 3605447195 No Response
Tarboro, NC 27886
Ray Bradley
2101 Stephanie Lane 3605448200
Clayton, NC 27520
O. R. Daniel, Jr.
PO Box 788
Fremont, NC 27830
Home Lodge No. 613
104 South Goldsboro Street 3605449337
Fremont, NC 27830
Helen Faye Lewis
718 Old Black Creek Road 3605445017
Fremont, NC 27830
Hooks & Co, LLC
1250 Hooks Road 3605444061
Fremont, NC 27830
Basem B. Ewais
2505 Memorial Church Road
Kenly, NC 27542
Basem B. Ewais
2505 Memorial Church Road
Kenly, NC 27542
Beatrice Jones
PO Box 477 3605442103 250 feet west Yes
Fremont, NC 27830
Saleh Odeh
PO Box 324 3605446433 175 feet north Yes
Fremont, NC 27830
Jamal A Sarama et al
PO Box 146 3605446592
Fremont, NC 27830
Joyner Bros. Investments, LLP
PO Box 218 3605437923
Nashville, NC 27856
O. R. Daniel, Jr.
PO Box 788
Fremont, NC 27830
Yvonne L. Sutton Booth
2105 Havering Place 3605436668 475 feet south Yes
Raleigh, NC 27604
Capital Café LLC
264 Pelt Road 3605449416 385 feet northeast Yes
Pikeville, NC 27863
PIN Number Letter
Delivered
TABLE 2
PROPERTY OWNERS WITHIN 500 FEET and SUSPECTED WELL LOCATIONS
SPEEDWAY NO. 7956
107 SOUTH WILSON STREET
FREMONT, WAYNE COUNTY, NORTH CAROLINA
FACILITY ID NO. 0-035993
ATC GROUP SERVICES OF NORTH CAROLINA, P.C. PROJECT NO. SWDP795603
Well InformationProperty Owner Contact
Information Property Address
WATER WELL SURVEY
Tenant/Description/
Zoning
Distance
(feet)/Direction
from site
No, Refused
and returned
Yes
No Response
107 South Wilson Street
Fremont, NC 3605445243 Yes No well on property
105 South Wilson Street
Fremont, NC
103 & 105 West Wayne Street
Fremont, NC
103 South Goldsboro Street
Fremont, NC
101 South Goldsboro Street
Fremont, NC
No Response
No Well on property.
3605444366,
3605443338
No, Refused
and returned
No, Refused
and returned
Yes
3605448233,
3605449207,
3605449323
No well on properties
Site
Adjacent north
Adjacent west
Adjacent
southeast across
US 17
Adjacent east
across US 17
No Response
No Well on Property
No well on property
106 East Main Street
Fremont, NC
200 South Goldsboro Street
Fremont, NC
202 & 206 South Goldsboro Street
Fremont, NC
204 South Goldsboro Street
Fremont, NC
102 East Main Street
Fremont, NC
103 South Wilson Street
Fremont, NC
No Response
Yes
Yes
No well on property
No wells on properties
No Response
No well on property
No well on property
No ResponseNo, Refused
and returned
Yes
Yes
No Response
No ResponseNo, Refused
and returned
Yes
Yes
Aggie's Pizza & Steak
Sub GB (General
Business)
Speedway Station
GB (General Business)
102 Wayne Street
Fremont, NC
104 South Goldsboro Street
Fremont, NC
201 South Wilson Street
Fremont, NC
110 & 106 South Goldsboro Street
Fremont, NC
3605445382
3605443180,
3605443100
3605449434,
3605449454
108 West Wayne Street
Fremont, NC
101 South Wilson Street
Fremont, NC
C Store
GB (General Business)
104 and 106 W. Wayne St.
Fremont, NC
3605437706,
3605436645
Dr. T. Gibson
Blackman GB (General
Business)
Single Family Home
GB (General Business)
Single family residence
GB (General Business)
Ray's Barber & Beauty
Shop
GB (General Business)
Ray's Barber & Beauty
Shop
GB (General Business)
Joyners's Great Value
(Grocer)
GB (General Business)
R10 (Residential)
R10 (Residential)
Restaurant
R10 (Residential)
Vacant warehouse
GB (General Business)
Single Family
residential R10
(Residential)
Telephone switching
station
GB (General Business)
Fraternal Order Lodge
GB (General Business)
Adjacent
northeast across
US 17
285 feet northeast
Adjacent south
across Wayne
Street
Adjacent south
across Wayne
Street
Adjacent
southwest across
Wayne Street
425 feet northeast
285 feet north
Adjacent
southeast across
Wayne Street
365 feet and 500
feet south
Wayne Mini-Mart GB
(General Business)
Sonny's Body Shop
GB (General Business)
PIN Number Letter
Delivered Well InformationProperty Owner Contact
Information Property AddressTenant/Description/
Zoning
Distance
(feet)/Direction
from site
Southern Bank & Trust
PO Box 729 3605447655 435 feet north Yes
Mt Olive, NC 28365
Alexas Watson
1301 Clingman Street 3605446793 470 feet north Yes
Goldsboro, NC 27534
Woodhaven Enterprises, LLC
PO Box 23 3605446793 485 feet north Yes
Goldsboro, NC 27533
James Paschal
639 Greenwood Circle 3605445749 495 feet north Yes
Cary, NC 27511
Fred D. Johnson
PO Box 2016
Fremont, NC 27830
Lou Ellen Flowers
PO Box 174 3605440520 Yes
Fremont, NC 27830
Leon Mooring
PO Box 248 36055344416 1,125 feet west Yes
Fremont, NC 27830
Judith F. Fuller
1483 NC Highway 55 West 3605444872
Mount Olive, NC 28365
Milton K. Sterart
PO Box 128 3605344148 1,050 feet west Yes
Fremont, NC 27830
Charles E. Rose
PO Box 814
Fremont, NC 27830
JMJ Mansour Rentals, LLC
PO Box 1536 3605540420 460 feet northeast Yes
Goldsboro, NC 27533
3605449399 450 feet northeast Yes
Harold P. Dew, Jr.
513 Main Street 3605449481 425 feet northeast Yes
Stantonsburg, NC 27863
Hardison Acres, LLC
PO Box 662 3605449461 400 feet northeast Yes
Fremont, NC 27830
Yes
No Response
108 East Main Street
Fremont, NC
101 North Wilson Street
Fremont, NC
107 West Main Street
Fremont, NC
144 and 201 Pine Street
Fremont, NC
207 South Pender Street
Fremont, NC
302 East Wayne Street
Fremont, NC
101 North Vance Street
Fremont, NC
114 East Main Street
Fremont, NC
112 East Main Street
Fremont, NC
110 East Main Street
Fremont, NC
No Response
No Response
No well on property
Office
GB (General Business)
Historical Society Office
GB (General Business)
1,090 feet east
525 feet north-
northwest
1,300 feet west-
southwest
No Response
No well on property
3605538415
Fremont Historical Museum and
Preservation Society, Inc.
PO Box 22, Fremont, NC 27830
3605441461,
3605440218
205 West Wayne Street
Fremont, NC
304 West Wayne Street
Fremont, NC
109 West Main Street
Fremont, NC
103 West Main Street
Fremont, NC
105 West Main Street
Fremont, NC
Vacant Storefront
GB (General Business)
Office
GB (General Business)
R10 (Residential)
R10 (Residential)
R10 (Residential)
R10 (Residential)
R10 (Residential)
R10 (Residential)
R10 (Residential)
R10 (Residential)
R10 (Residential)
R10 (Residential)
Southern Bank
GB (General Business)
No well on property
One well depth unknown;
used for irrigation and filling
swimming pool
No well on property
No well on property
No Response
No Response
No Response
No Response
Yes, well is 35 feet deep.
Installed in 1904 when
house was built. Used to fill
small fish pond and water
grass. Well is not used for
potable water.
3605546380 485 feet west Yes
Walter J. Marm
101 North Vance Street
Fremont, NC 27830
Yes
No, Refused
and returned
550 feet northwest
BenzeneTolueneEthylbenzeneTotal XylenesTotal BTEXNaphthaleneDi-isopropyl etherMethyl tert-butyl ether (MTBE)C5-C8 AliphaticsC9-C12 AliphaticsC9-C10 AromaticsTotal VPH0.0056 4.3 4.9 4.6 ---0.16 0.37 0.091 68 540 31 ---
18 1,200 1,560 3,129 ---313 156 350 939 1,500 469 ---
164 32,000 40,000 81,760 ---8,176 4,088 3,100 24,528 40,000 12,264 ---
MW-01 2 07/08/19 10.8 0.00764 0.0209 0.0127 0.0380 0.07924 0.0237 <0.001 <0.001 <6.80 <6.80 <6.80 <6.80
MW-02 6 07/08/19 1.4 <0.001 0.0401 <0.0025 <0.0065 0.0401 <0.0125 <0.001 <0.001 <5 <5 <5 <5
MW-03 6 07/08/19 20.1 0.00245 0.0475 0.0236 0.0107 0.08425 0.0803 <0.00101 0.00106 <5 <5 <5 <5
Notes:
1. Concentrations reported in milligrams per kilogram (mg/kg).
2. The MADEP VPH values were obtained from Table 10 in the "Guidelines for Assessment and corrective Action for UST Releases, dated July 15, 2008, updated October 2012.
3. MSCCs = Maximum Soil Contaminant Concentration
4. Italics type denotes concentration equals or exceeds Soil-to-Groundwater MSCCs.
5. BOLD type denotes concentration equals or exceeds Residential MSCCs.
6. BOLD/Underline denotes concentration equals or exceeds Industrial/Commercial MSCCs.
7. "<" denotes compound not detected above laboratory method detection limit.
8. BRL = Below Laboratory Reporting Limits.
MADEP Method for VPH
FACILITY ID NO. 0-035993
ATC GROUP SERVICES OF NORTH CAROLINA, P.C. PROJECT NO. SWDP795603
TABLE 3
SUMMARY OF SOIL ANALYTICAL RESULTS
SPEEDWAY NO. 7956
107 SOUTH WILSON STREET
FREMONT, WAYNE COUNTY, NORTH CAROLINA
Soil-to-Groundwater MSCCs
Residential MSCCs
Industrial/Commercial MSCCs
EPA Method 8260
Soil Sample
ID
Sample
Depth
(feet)
Sampling
Date
PID
Reading
Parts Per
Million
(ppm)
EPA
Method
504.1
EPA
Method
6010D
BenzeneTolueneEthylbenzeneTotal XylenesTotal BTEXNaphthaleneMethyl tert-butyl ether (MTBE)1, 2-Dichloroethane (DCA)Di-Isopropyl EtherEthylene DibromideLeadC5-C8 AliphaticsC9-C12 AliphaticsC9-C10 AromaticsTotal VPH1 600 600 500 ---6 20 0.4 70 0.02 15 400 700 200 NE
5,000 260,000 84,500 85,500 ---6,000 20,000 400 70,000 50 15,000 NE NE NE NE
MW-01 07/16/19 132 4,880 1,610 5,660 12,282 388 <10 <10 <10 0.0613 116 17,000 12,700 3,460 33,200
MW-02 07/16/19 123 1,690 2,010 6,890 10,713 571 <10 <10 <10 <0.01 78.9 14,500 17,600 5,830 37,900
MW-03 07/16/19 266 4,970 1,050 4,940 11,226 277 <20 <20 <20 0.118 26 14,700 10,900 2,910 28,500
Notes:
1. Laboratory results concentrations reported in micrograms per liter (µg/L).
2. 2L Standard limits reported in micrograms per liter (µg/L).
3. Gross Contamination Levels (GCL) reported in micrograms per liter (µg/L).
4. Italics type denotes concentration equals or exceeds - 2L Standard
5. BOLD/Underline denotes concentration equals or exceeds - GCL = Gross Contaminant Level
6. "<" denotes compound not detected above laboratory reporting limits.
7. J value denotes estimated concentration by the laboratory.
8. NE = Not Established.
2L Standard (µg/L)
GCL (µg/L)
EPA Method 6200B
ATC GROUP SERVICES OF NORTH CAROLINA, P.C. PROJECT NO. SWDP795603
Groundwater
Sample ID
Sampling
Date
MADEP Method for VPH
FACILITY ID NO. 0-035993
TABLE 4
SUMMARY OF GROUNDWATER ANALYTICAL RESULTS
SPEEDWAY NO. 7956
107 SOUTH WILSON STREET
FREMONT, WAYNE COUNTY, NORTH CAROLINA
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Speedway No. 7956
FIGURES
N
SITE
LOCATION
SITE LOCATION MAP
DATE:PROJECT NO.:
SCALE:
FIGURE 1
DRAWN BY:
REVIEWED BY:803-741-2444PH:COLUMBIA, SC 292237499 PARKLANE ROAD, SUITE 112
FAX:EMAIL: WWW.ATCGROUPSERVICES.COM803-735-0003
SC UST CONTRACTOR No. 0313
SOUTH WILSON STREETEAS
T
W
A
Y
N
E
S
T
R
E
E
T
FIGURE 2
PROJECT NO.:
DRAWN BY:
REVIEWED BY:
DATE:
SCALE:
SITE MAP
N
803-741-2444PH:
COLUMBIA, SC 292237499 PARKLANE ROAD, SUITE 112
FAX:
EMAIL: WWW.ATCGROUPSERVICES.COM
803-735-0003
SC UST CONTRACTOR No. 0313
SOUTH WILSON STREETEAS
T
W
A
Y
N
E
S
T
R
E
E
T
PROJECT NO.:
DRAWN BY:
REVIEWED BY:
DATE:
SCALE:
N
FIGURE 3
SOIL CONCENTRATION MAP
BOLD
BOLD
803-741-2444PH:
COLUMBIA, SC 292237499 PARKLANE ROAD, SUITE 112
FAX:
EMAIL: WWW.ATCGROUPSERVICES.COM
803-735-0003
SC UST CONTRACTOR No. 0313
SOUTH WILSON STREET
EAS
T
W
A
Y
N
E
S
T
R
E
E
T
PROJECT NO.:
DRAWN BY:
REVIEWED BY:
DATE:
SCALE:
N
FIGURE 4
BOLD
JULY 16, 2019
CONCENTRATIONS OF PETROLEUM CONSTITUENTS MAP
803-741-2444
PH:
COLUMBIA, SC 29223
7499 PARKLANE ROAD, SUITE 112
FAX:
EMAIL: WWW.ATCGROUPSERVICES.COM
803-735-0003
SC UST CONTRACTOR No. 0313
SOUTH WILSON STREET
EAS
T
W
A
Y
N
E
S
T
R
E
E
T
PROJECT NO.:
DRAWN BY:
REVIEWED BY:
DATE:
SCALE:
N
803-741-2444
PH:
COLUMBIA, SC 29223
7499 PARKLANE ROAD, SUITE 112
FAX:
EMAIL: WWW.ATCGROUPSERVICES.COM
803-735-0003
SC UST CONTRACTOR No. 0313
JULY 16, 2019
GROUNDWATER ELEVATION CONTOUR MAP
FIGURE 5
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Speedway No. 7956
APPENDIX A
LIMITED SITE ASSESSMENT REPORT
REVIEW LABORATORY ANALYTICAL
RESULTS - GROUNDWATER
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Speedway No. 7956
APPENDIX B
NCDEQ RISK CLASSIFICATION AND
LAND USE FORM
Site Name: Speedway Store No. 7956
NCDEQ Incident No. 38681
NCDEQ Facility I.D. No. 0-035993
Limited Site Assessment Risk Classification and Land Use Form
Part I – Groundwater/Surface Water/Vapor Impacts
High Risk
1. Has the release contaminated any water supply well including any well used for non-drinking
purposes? NO
2. Is a water supply well used for drinking water located within 1,000 feet of the source area of the
release? NO
3. Is a water supply well not used for drinking water (e.g., irrigation, washing cars, industrial
cooling water, filling swimming pools) located within 250 feet of the source area of the
release? NO
4. Does groundwater within 500 feet of the source area of the release have the potential
for future use? YES
5. Do vapors from the release pose a threat of explosion because of accumulation of the vapors in
a confined space or pose any other serious threat to public health, public safety or the
environment? NO
If yes, describe. N/A
6. Are there any other factors that would cause the release to pose an imminent danger
to public health, public safety, or the environment? NO
If yes, describe. N/A
Intermediate Risk
7. Is a surface water body located within 500 feet of the source area of the release?
NO
If YES, does the maximum groundwater contaminant concentration exceed the surface
water quality standards and criteria found in 15A NCAC 2B .0200 by a factor of 10?
N/A
8. Is the source area of the release located within an approved or planned wellhead protection
area as defined in 42 USC 300h-7(e)? NO
If yes, describe. N/A
9. Is the release located in the Coastal Plain physiographic region as designated on a map
entitled “Geology of North Carolina” published by the Department in 1985? YES
If YES, is the source area of the release located in an area in which there is recharge
to an unconfined or semi-confined deeper aquifer that is being used or may be used as a
source of drinking water? NO
If YES, describe. N/A
10. Do the levels of groundwater contamination for any contaminant exceed the gross
contamination levels (see Table 9) established by the Department? NO
Site Name: Speedway Store No. 7956
NCDEQ Incident No. 38681
NCDEQ Facility I.D. No. 0-035993
Part II – Land Use
Property Containing Source Area of Release
The questions below pertain to the property containing the source area of the release.
1. Does the property contain one or more primary or secondary residences (permanent
or temporary)? NO
Describe. No, the site consists of a convenience store with petroleum retail sales
2. Does the property contain a school, daycare center, hospital, playground, park, recreation
area, church, nursing home, or other place of public assembly? NO
Describe. No, the site consists of a convenience store with petroleum retail sales.
3. Does the property contain a commercial (e.g., retail, warehouse, office/business space,
etc.) or industrial (e.g., manufacturing, utilities, industrial research and development,
chemical/petroleum bulk storage, etc.) enterprise, an inactive commercial or industrial
enterprise, or is the land undeveloped? YES
Describe. The site consists of a convenience store with petroleum retail sales.
4. Do children visit the property? YES
Explain. Yes, children with their parents may visit the property.
Is access to the property reliably restricted consistent with its use (e.g., by fences, security
personnel or both)? NO
Explain. No, the site is accessible and is not surrounded by a fence and is not secured.
5. Does pavement, buildings, or other structures cap the contaminated soil? YES
Describe. Yes, the majority of the site is covered with concrete and asphalt.
If yes, what mechanisms are in place or can be put into place to ensure that the
contaminated soil will remain capped in the foreseeable future? The site will likely
remain a petroleum service station with concrete and asphalt cover.
6. What is the zoning status of the property? GB (General Business)
7. Is the use of the property likely to change in the next 20 years? NO
Explain. No, the site has been used as a petroleum service station, and the property usage
is not expected to change.
Site Name: Speedway Store No. 7956
NCDEQ Incident No. 38681
NCDEQ Facility I.D. No. 0-035993
Property Surrounding Source Area of Release
The questions below pertain to the area within 1,500 feet of the source area of the release (excludes
property containing source area of the release):
1. What is the distance from the source area of the release to the nearest primary or
secondary residence (permanent or temporary)? There is a residence located 250 feet
west of the source area (the residential property is zoned R-10 (Residential-Single
Family).
2. What is the distance from the source area of the release to the nearest school,
daycare center, hospital, playground, park, recreation area, church, nursing home or other
place of public assembly? The closest place of public assembly is the Town Hall of
Fremont located approximately 560 feet northeast of the release area.
3. What is the zoning status of properties in the surrounding area? GB (General
Business) and R-10 (Residential Single Family),
Briefly characterize the use and activities of the land in the surrounding area: The properties
surrounding the subject facility are zoned GB (General Business) and R-10 (Residential
Single Family), residences, and retail businesses characterize the surrounding area. Retail
businesses are located along the Wilson Street corridor, and residences are located west of
the site.
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Speedway No. 7956
APPENDIX C
WATER SUPPLY WELL MAILING FORMS AND WATER SUPPLY
WELL LOCATION MAP
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Trade Family, LLC
Post Office Box 3435
Greenville, North Carolina 27836
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956 located at 107 South Wilson Street, Fremont,
North Carolina. The investigation is being conducted pursuant to North Carolina Department of
Environment Quality (NCDEQ) guidelines associated with a release of petroleum. ATC
understands that you own the property in Fremont, North Carolina, Tax PIN Number
3605445243, which is the current location of Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Ms. Cammie Odeh
4960 US Hwy 13 South
Goldsboro, North Carolina 27530
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Ms. Odeh:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 105 South Wilson Street, Fremont,
North Carolina, Tax PIN Number 3605445382, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Mr. Jason D. Capps
Post Office Box 173
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Mr. Capps:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the properties at 103 and 105 West Wayne Street,
Fremont, North Carolina, Tax PIN Numbers 3605444366 and 3605443338, which are near
Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
NC Telephone & Telegraph Co.
1825 Sunset Avenue
Tarboro North Carolina 27804
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 103 South Goldsboro Street,
Fremont, North Carolina, Tax PIN Number 3605447195, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Mr. Ray Bradley
2101 Stephanie Lane
Clayton, North Carolina 27520
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Mr. Bradley:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 101 South Goldsboro Street,
Fremont, North Carolina, Tax PIN Number 3605448200, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Mr. O.R. Daniel Jr.
Post Office Box 788
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Mr. Daniel:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the properties at 106, 110, 202 and 206 South
Goldsboro Street Fremont, North Carolina, Tax PIN Numbers 3605448233,
3605449207,3605437706, 3605436645 and 360544932, which are near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Home Lodge No. 613
104 South Goldsboro Street
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 104 South Goldsboro Street,
Fremont, North Carolina, Tax PIN Number 3605449337, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Ms. Helen Faye Lewis
718 Old Black Creek Road
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Ms. Lewis:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 201 South Wilson Street, Fremont,
North Carolina, Tax PIN Number 3605445017, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Hooks & Co. LLC
1250 Hooks Road
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 102 Wayne Street, Fremont, North
Carolina, Tax PIN Number 3605444061, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Basem B. Ewais
2505 Memorial Church Road
Kenly, North Carolina 27542
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 104-106 West Wayne Street and 106
East Main Street, Fremont, North Carolina, Tax PIN Numbers 3605443100, 3605443180,
3605449434 and 3605443654, which are near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Ms. Beatrice Jones
Post Office Box 4777
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Ms. Jones:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 108 West Wayne Street, Fremont,
North Carolina, Tax PIN Number 3605442103, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Saleh Odeh
Post Office Box 324
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 103 South Wilson Street, Fremont,
North Carolina, Tax PIN Number 3605446433, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Jamal A. Sarama et al
Post Office Box 146
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 101 South Wilson Street, Fremont,
North Carolina, Tax PIN Number 3605446592, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Joyner Bros. Investments, LLP
Post Office Box 218
Nashville, North Carolina 27856
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 200 Wayne Street, Fremont, North
Carolina, Tax PIN Number 3605437923, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 1, 2019 (return options are listed at the bottom of the enclosed form). A
self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Yvonne L. Sutton Booth
2105 Havering Place
Raleigh, North Carolina 27604
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Ms. Booth:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 204 South Goldsboro Street,
Fremont, North Carolina, Tax PIN Number 3605436668, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Capital Café LLC
264 Pelt Road
Pikeville, North Carolina 27863
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 102 East Main Street, Fremont,
North Carolina, Tax PIN Number 3605449416, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Southern Bank & Trust
Post Office Box 729
Mount Olive, North Carolina 28365
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 101 North Wilson Street, Fremont,
North Carolina, Tax PIN Number 3605447655, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Alexas Watson
1301 Clingman Street
Goldsboro, North Carolina 27534
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 103 West Main Street, Fremont,
North Carolina, Tax PIN Number 3605446793, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Woodhaven Enterprises, LLC
Post Office Box 23
Goldsboro, North Carolina 27534
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 105 West Main Street, Fremont,
North Carolina, Tax PIN Number 3605446793, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Mr. Fred D. Johnson
Post Office Box 2016
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Mr. Johnson:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the properties at 144 and 201 Pine Street, Fremont,
North Carolina, Tax PIN Numbers 3605441462 and 3605440218, which are near Speedway No.
7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Ms. Lou Ellen Flowers
Post Office Box 174
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Ms. Flowers:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 205 West Wayne Street, Fremont,
North Carolina, Tax PIN Number 3605440520, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Mr. Leon Mooring
Post Office Box 248
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Mr. Mooring:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 304 West Wayne Street, Fremont,
North Carolina, Tax PIN Number 360544416, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Ms. Judith Fuller
1483 NC Hwy 55 West
Mount Olive, North Carolina 28365
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Ms. Fuller:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 109 West Main Street, Fremont,
North Carolina, Tax PIN Number 3605444872, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Mr. Milton K. Sterart
Post Office Box 128
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Mr. Sterart:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 207 South Pender Street, Fremont,
North Carolina, Tax PIN Number 3605344148, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Mr. Charles E. Rose
Post Office Box 814
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Mr. Rose:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 302 East Wayne Street, Fremont,
North Carolina, Tax PIN Number 3605538415, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Mr. Walter J. Marm
Post Office Box 2017
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Mr. Marm:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 101 Vance Street, Fremont, North
Carolina, Tax PIN Number 3605546380, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
JMJ Mansour Rentals LLC
Post Office Box 1536
Goldsboro, North Carolina 27533
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 114 East Main Street, Fremont,
North Carolina, Tax PIN Number 3605540420, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Fremont Historical Museum and Preservation Society, Inc.
Post Office Box 22
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 112 East Main Street, Fremont,
North Carolina, Tax PIN Number 3605449399, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Mr. Harold P. Dew Jr.
513 Main Street
Stantonsburg, North Carolina 27863
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
Dear Mr. Dew:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 110 East Main Street, Fremont,
North Carolina, Tax PIN Number 3605449481, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
Speedway LLC
500 Speedway Drive
Enon, Ohio 45323
Telephone 937-864-3000
March 5, 2019
Certified Mail
Return Receipt Requested
Hardison Acres LLC
Post Office Box 662
Fremont, North Carolina 27830
RE: Private Water Supply Well Survey
Speedway No. 7956
107 South Wilson Street
Fremont, North Carolina
To Whom It May Concern:
ATC Group Services LLC (ATC), on behalf of Speedway LLC (Speedway), is performing a
groundwater investigation at Speedway No. 7956, which is located at 107 South Wilson Street,
Fremont, North Carolina. The investigation is being conducted pursuant to North Carolina
Department of Environment Quality (NCDEQ) guidelines associated with a release of
petroleum. ATC understands that you own the property at 108 East Main Street, Fremont,
North Carolina, Tax PIN Number 3605449461, which is near Speedway No. 7956.
To comply with the requirements of the NCDEQ, please review and complete the enclosed
water supply well information form. Please return the enclosed form to the ATC Virginia Beach,
Virginia office by March 25, 2019 (return options are listed at the bottom of the enclosed form).
A self-addressed envelope is provided for your convenience.
If you have any questions or require additional information, please contact me at 937-863-6507
or by email at bmwitt@speedway.com.
Sincerely,
Speedway LLC
Bryan M. Witt
Environmental Representative
Enclosure
cc: ATC Group Services LLC, 211 Expressway Court, Virginia Beach, Virginia 23462
CAD FILE PREP. BYTYPE CODE REV. BY SCALE PROJECT NO.
TITLE
DATE
NOTES:
Virginia Beach, Virginia 23462
(757) 467-2100 FAX (757) 467-9178
GEOTECHNICALENVIRONMENTAL
MATERIALS TESTINGBUILDING SCIENCES
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Speedway No. 7956
APPENDIX D
SOIL BORING/WELL LOGS AND NCDEQ WELL CONSTRUCTION
RECORDS
08-09-2019 S:\Projects\Speedway LLC\7956-Fremont\Boring Logs\MW-02.borATC Project No.SWDP795604
Fremont, North Carolina
107 South Wilson Street
Speedway No. 7956
Soil Boring Log: MW-01
(Page 1 of 1)
Date(s) Drilled : 07/08/2019
Drilling Contractor : ARM Environmental
Driller : Josh Register
Drilling Method : Hollow Stem Auger
Boring Diameter : 6.25
Sampling Method : Split Spoon
Sampling Interval : 2 Feet
Logged By : Emily Fuller
Depth In Feet0
2
4
6
8
10
12
14 USCSGRAPHICDESCRIPTION
PID Readings (ppm)SM
SM
CL
Concrete
crusher run
Brown medium grained sandy SILT
Light Brown to orange clayey SILT
Light brown silty CLAY
End of Boring
10.8
0.3
0.0
Boring terminated at 13' bgs.
Soils wet at 8 feet below ground surface
Static water table at 7.14 feet below casing during gw sampling event.
Soil samples not obtained below 8 feet
Well: MW-01
Concrete
Grout
Bentonite
Sand Pack
Cover
Casing
Screen
08-09-2019 S:\Projects\Speedway LLC\7956-Fremont\Boring Logs\MW-02.borATC Project No.SWDP795604
Fremont, North Carolina
107 South Wilson Street
Speedway No. 7956
Boring terminated at 13' bgs.
Soils wet at 8 feet below ground surface
Static water table at 6.41 feet below casing during gw sampling event.
Soil samples not obtained below 8 feet
Soil Boring Log: MW-02
(Page 1 of 1)
Date(s) Drilled : 07/08/2019
Drilling Contractor : ARM Environmental
Driller : Josh Register
Drilling Method : Hollow Stem Auger
Boring Diameter : 6.25
Sampling Method : Split Spoon
Sampling Interval : 2 Feet
Logged By : Emily Fuller
Depth In Feet0
2
4
6
8
10
12
14 USCSSM GRAPHICDESCRIPTION
Concrete
crusher run
Brown SILT with gravel
Light brown silty CLAY
End of Boring PID Readings (ppm)0.2
0.5
1.4
Well: MW-02
Concrete
Grout
Bentonite
Sand Pack
Cover
Casing
Screen
08-09-2019 S:\Projects\Speedway LLC\7956-Fremont\Boring Logs\MW-03.borATC Project No.SWDP795604
Fremont, North Carolina
107 South Wilson Street
Speedway No. 7956
Boring terminated at 13' bgs.
Soils wet at 8 feet below ground surface
Static water table at 6.79 feet below casing during gw sampling event.
Soil samples not obtained below 8 feet
Soil Boring Log: MW-03
(Page 1 of 1)
Date(s) Drilled : 07/08/2019
Drilling Contractor : ARM Environmental
Driller : Josh Register
Drilling Method : Hollow Stem Auger
Boring Diameter : 6.25
Sampling Method : Split Spoon
Sampling Interval : 2 Feet
Logged By : Emily Fuller
Depth In Feet0
2
4
6
8
10
12
14 USCSGRAPHICDESCRIPTION
PID Readings (ppm)Well: MW-03
Concrete
Grout
Bentonite
Sand Pack
Cover
Casing
Screen
ML
ML
CL
Concrete
crusher run
Gray clayey SILT
Light brown to orange clayey SILT.
Reddish brown to orange-tan silty CLAY
End of boring
9.3
8.5
20.1
UNON RESIDENTIAL WELL CONSTRUCTION RECORD
North Carolina Department of Environment and Natural Resources- Division of Water Quality
WELL CONTRACTOR CERTIFICATION # ___________________________
1. WELL CONTRACTOR:
_________________________________________________________Well Contractor (Individual) Name
_________________________________________________________
Well Contractor Company Name
_________________________________________________________Street Address
_________________________________________________________City or Town State Zip Code
(_______) __________________________Area code Phone number
2. WELL INFORMATION:
WELL CONSTRUCTION PERMIT#______________________________
OTHER ASSOCIATED PERMIT#(if applicable)______________________
SITE WELL ID #(if applicable)______________________________
3. WELL USE (Check One Box) Monitoring ⃞Municipal/Public ⃞
Industrial/Commercial ⃞Agricultural ⃞Recovery ⃞Injection ⃞
Irrigation⃞Other ⃞(list use) ____________________________
DATE DRILLED_____________________
4. WELL LOCATION:
_________________________________________________________ (Street Name, Numbers, Community, Subdivision, Lot No., Parcel, Zip Code)
CITY: ____________________________ COUNTY________________
TOPOGRAPHIC / LAND SETTING: (check appropriate box)
⃞Slope ⃞Valley ⃞Flat ⃞Ridge ⃞Other___________________
/$7,78'(BBBBBBBBBB
BBBBBBBBB'0625BBBBBBBBBBBBB''
/21*,78'(BBBBBBBBB
BBBBBBBBB'0625BBBBBBBBBBBBB''
Latitude/longitude source: ⃞GPS ⃞Topographic map
(location of well must be shown on a USGS topo map andattached to
this form if not using GPS)
5. FACILITY (Name of the business where the well is located.)
_________________________________________________________
Facility Name Facility ID# (if applicable)
_________________________________________________________Street Address
_________________________________________________________City or Town State Zip Code
_________________________________________________________
Contact Name
_________________________________________________________
Mailing Address
_________________________________________________________City or Town State Zip Code
(_______) __________________________Area code Phone number
6. WELL DETAILS:
a. TOTAL DEPTH:___________________
b. DOES WELL REPLACE EXISTING WELL?YES ⃞NO ⃞
c. WATER LEVEL Below Top of Casing: _______________FT.(Use “+” if Above Top of Casing)
d. TOP OF CASING IS _____________ FT. Above Land Surface**Top of casing terminated at/or below land surface may require a variance in accordance with 15A NCAC 2C .0118.
e. YIELD (gpm): ___________ METHOD OF TEST______________
f. DISINFECTION: Type_______________ Amount ____________
g. WATER ZONES (depth):
Top_________ Bottom_________ Top_________ Bottom_________
Top_________ Bottom_________ Top_________ Bottom_________
Top_________ Bottom_________ Top_________ Bottom_________
Thickness/
7. CASING: Depth Diameter Weight Material
Top_______ Bottom_______ Ft.________ _______ ___________
Top_______ Bottom_______ Ft.________ _______ ___________
Top_______ Bottom_______ Ft.________ _______ ___________
8. GROUT: Depth Material Method
Top_______ Bottom_______ Ft.______________ ______________
Top_______ Bottom_______ Ft.______________ ______________
Top_______ Bottom_______ Ft.______________ ______________
9. SCREEN: Depth Diameter Slot Size Material
Top_______ Bottom_______ Ft.______in. ______ in. ____________
Top_______ Bottom_______ Ft.______in. ______ in. ____________
Top_______ Bottom_______ Ft.______in. ______ in. ____________
10. SAND/GRAVEL PACK:Depth Size Material
Top________Bottom_______ Ft.________ ______________________
Top________Bottom_______ Ft.________ ______________________
Top________Bottom_______ Ft.________ ______________________
11.DRILLING LOGTop Bottom Formation Description
12. REMARKS:_________________________________________________________
_________________________________________________________
__________________________________________________ PRINTED NAME OF PERSON CONSTRUCTING THE WELL
Form GW-1bRev. /0
______/_________ _________________________________/_________ _________________________________/_________ ___________________________
______/_________ _________________________________/_________ _________________________________/_________ ___________________________
______/_________ _________________________________/_________ _________________________________/_________ ___________________________
______/_________ _________________________________/_________ ___________________________
Submit within 30 days of completion to: Division of Water Quality -Information Processing,
1617 Mail Service Center, Raleigh, NC 27699-161, Phone : (919) 807-6300
_____________________________________ _____ ___________SIGNATURE OF CERTIFIED WELL CONTRACTOR DATE
I DO HEREBY CERTIFY THAT THIS WELL WAS CONSTRUCTED IN ACCORDANCE WITH15A NCAC 2C, WELL CONSTRUCTION STANDARDS, AND THAT A COPY OF THIS RECORD HAS BEEN PROVIDED TO THE WELL OWNER.
UNON RESIDENTIAL WELL CONSTRUCTION RECORD
North Carolina Department of Environment and Natural Resources- Division of Water Quality
WELL CONTRACTOR CERTIFICATION # ___________________________
1. WELL CONTRACTOR:
_________________________________________________________Well Contractor (Individual) Name
_________________________________________________________
Well Contractor Company Name
_________________________________________________________Street Address
_________________________________________________________City or Town State Zip Code
(_______) __________________________Area code Phone number
2. WELL INFORMATION:
WELL CONSTRUCTION PERMIT#______________________________
OTHER ASSOCIATED PERMIT#(if applicable)______________________
SITE WELL ID #(if applicable)______________________________
3. WELL USE (Check One Box) Monitoring ⃞Municipal/Public ⃞
Industrial/Commercial ⃞Agricultural ⃞Recovery ⃞Injection ⃞
Irrigation⃞Other ⃞(list use) ____________________________
DATE DRILLED_____________________
4. WELL LOCATION:
_________________________________________________________ (Street Name, Numbers, Community, Subdivision, Lot No., Parcel, Zip Code)
CITY: ____________________________ COUNTY________________
TOPOGRAPHIC / LAND SETTING: (check appropriate box)
⃞Slope ⃞Valley ⃞Flat ⃞Ridge ⃞Other___________________
/$7,78'(BBBBBBBBBB
BBBBBBBBB'0625BBBBBBBBBBBBB''
/21*,78'(BBBBBBBBB
BBBBBBBBB'0625BBBBBBBBBBBBB''
Latitude/longitude source: ⃞GPS ⃞Topographic map
(location of well must be shown on a USGS topo map andattached to
this form if not using GPS)
5. FACILITY (Name of the business where the well is located.)
_________________________________________________________
Facility Name Facility ID# (if applicable)
_________________________________________________________Street Address
_________________________________________________________City or Town State Zip Code
_________________________________________________________
Contact Name
_________________________________________________________
Mailing Address
_________________________________________________________City or Town State Zip Code
(_______) __________________________Area code Phone number
6. WELL DETAILS:
a. TOTAL DEPTH:___________________
b. DOES WELL REPLACE EXISTING WELL?YES ⃞NO ⃞
c. WATER LEVEL Below Top of Casing: _______________FT.(Use “+” if Above Top of Casing)
d. TOP OF CASING IS _____________ FT. Above Land Surface**Top of casing terminated at/or below land surface may require a variance in accordance with 15A NCAC 2C .0118.
e. YIELD (gpm): ___________ METHOD OF TEST______________
f. DISINFECTION: Type_______________ Amount ____________
g. WATER ZONES (depth):
Top_________ Bottom_________ Top_________ Bottom_________
Top_________ Bottom_________ Top_________ Bottom_________
Top_________ Bottom_________ Top_________ Bottom_________
Thickness/
7. CASING: Depth Diameter Weight Material
Top_______ Bottom_______ Ft.________ _______ ___________
Top_______ Bottom_______ Ft.________ _______ ___________
Top_______ Bottom_______ Ft.________ _______ ___________
8. GROUT: Depth Material Method
Top_______ Bottom_______ Ft.______________ ______________
Top_______ Bottom_______ Ft.______________ ______________
Top_______ Bottom_______ Ft.______________ ______________
9. SCREEN: Depth Diameter Slot Size Material
Top_______ Bottom_______ Ft.______in. ______ in. ____________
Top_______ Bottom_______ Ft.______in. ______ in. ____________
Top_______ Bottom_______ Ft.______in. ______ in. ____________
10. SAND/GRAVEL PACK:Depth Size Material
Top________Bottom_______ Ft.________ ______________________
Top________Bottom_______ Ft.________ ______________________
Top________Bottom_______ Ft.________ ______________________
11.DRILLING LOGTop Bottom Formation Description
12. REMARKS:_________________________________________________________
_________________________________________________________
__________________________________________________ PRINTED NAME OF PERSON CONSTRUCTING THE WELL
Form GW-1bRev. /0
______/_________ _________________________________/_________ _________________________________/_________ ___________________________
______/_________ _________________________________/_________ _________________________________/_________ ___________________________
______/_________ _________________________________/_________ _________________________________/_________ ___________________________
______/_________ _________________________________/_________ ___________________________
Submit within 30 days of completion to: Division of Water Quality -Information Processing,
1617 Mail Service Center, Raleigh, NC 27699-161, Phone : (919) 807-6300
_____________________________________ _____ ___________SIGNATURE OF CERTIFIED WELL CONTRACTOR DATE
I DO HEREBY CERTIFY THAT THIS WELL WAS CONSTRUCTED IN ACCORDANCE WITH15A NCAC 2C, WELL CONSTRUCTION STANDARDS, AND THAT A COPY OF THIS RECORD HAS BEEN PROVIDED TO THE WELL OWNER.
UNON RESIDENTIAL WELL CONSTRUCTION RECORD
North Carolina Department of Environment and Natural Resources- Division of Water Quality
WELL CONTRACTOR CERTIFICATION # ___________________________
1. WELL CONTRACTOR:
_________________________________________________________Well Contractor (Individual) Name
_________________________________________________________
Well Contractor Company Name
_________________________________________________________Street Address
_________________________________________________________City or Town State Zip Code
(_______) __________________________Area code Phone number
2. WELL INFORMATION:
WELL CONSTRUCTION PERMIT#______________________________
OTHER ASSOCIATED PERMIT#(if applicable)______________________
SITE WELL ID #(if applicable)______________________________
3. WELL USE (Check One Box) Monitoring ⃞Municipal/Public ⃞
Industrial/Commercial ⃞Agricultural ⃞Recovery ⃞Injection ⃞
Irrigation⃞Other ⃞(list use) ____________________________
DATE DRILLED_____________________
4. WELL LOCATION:
_________________________________________________________ (Street Name, Numbers, Community, Subdivision, Lot No., Parcel, Zip Code)
CITY: ____________________________ COUNTY________________
TOPOGRAPHIC / LAND SETTING: (check appropriate box)
⃞Slope ⃞Valley ⃞Flat ⃞Ridge ⃞Other___________________
/$7,78'(BBBBBBBBBB
BBBBBBBBB'0625BBBBBBBBBBBBB''
/21*,78'(BBBBBBBBB
BBBBBBBBB'0625BBBBBBBBBBBBB''
Latitude/longitude source: ⃞GPS ⃞Topographic map
(location of well must be shown on a USGS topo map andattached to
this form if not using GPS)
5. FACILITY (Name of the business where the well is located.)
_________________________________________________________
Facility Name Facility ID# (if applicable)
_________________________________________________________Street Address
_________________________________________________________City or Town State Zip Code
_________________________________________________________
Contact Name
_________________________________________________________
Mailing Address
_________________________________________________________City or Town State Zip Code
(_______) __________________________Area code Phone number
6. WELL DETAILS:
a. TOTAL DEPTH:___________________
b. DOES WELL REPLACE EXISTING WELL?YES ⃞NO ⃞
c. WATER LEVEL Below Top of Casing: _______________FT.(Use “+” if Above Top of Casing)
d. TOP OF CASING IS _____________ FT. Above Land Surface**Top of casing terminated at/or below land surface may require a variance in accordance with 15A NCAC 2C .0118.
e. YIELD (gpm): ___________ METHOD OF TEST______________
f. DISINFECTION: Type_______________ Amount ____________
g. WATER ZONES (depth):
Top_________ Bottom_________ Top_________ Bottom_________
Top_________ Bottom_________ Top_________ Bottom_________
Top_________ Bottom_________ Top_________ Bottom_________
Thickness/
7. CASING: Depth Diameter Weight Material
Top_______ Bottom_______ Ft.________ _______ ___________
Top_______ Bottom_______ Ft.________ _______ ___________
Top_______ Bottom_______ Ft.________ _______ ___________
8. GROUT: Depth Material Method
Top_______ Bottom_______ Ft.______________ ______________
Top_______ Bottom_______ Ft.______________ ______________
Top_______ Bottom_______ Ft.______________ ______________
9. SCREEN: Depth Diameter Slot Size Material
Top_______ Bottom_______ Ft.______in. ______ in. ____________
Top_______ Bottom_______ Ft.______in. ______ in. ____________
Top_______ Bottom_______ Ft.______in. ______ in. ____________
10. SAND/GRAVEL PACK:Depth Size Material
Top________Bottom_______ Ft.________ ______________________
Top________Bottom_______ Ft.________ ______________________
Top________Bottom_______ Ft.________ ______________________
11.DRILLING LOGTop Bottom Formation Description
12. REMARKS:_________________________________________________________
_________________________________________________________
__________________________________________________ PRINTED NAME OF PERSON CONSTRUCTING THE WELL
Form GW-1bRev. /0
______/_________ _________________________________/_________ _________________________________/_________ ___________________________
______/_________ _________________________________/_________ _________________________________/_________ ___________________________
______/_________ _________________________________/_________ _________________________________/_________ ___________________________
______/_________ _________________________________/_________ ___________________________
Submit within 30 days of completion to: Division of Water Quality -Information Processing,
1617 Mail Service Center, Raleigh, NC 27699-161, Phone : (919) 807-6300
_____________________________________ _____ ___________SIGNATURE OF CERTIFIED WELL CONTRACTOR DATE
I DO HEREBY CERTIFY THAT THIS WELL WAS CONSTRUCTED IN ACCORDANCE WITH15A NCAC 2C, WELL CONSTRUCTION STANDARDS, AND THAT A COPY OF THIS RECORD HAS BEEN PROVIDED TO THE WELL OWNER.
Phase II Limited Site Assessment Report
Speedway No. 7956
August 21, 2019 ATC Group Services LLC
Speedway No. 7956
APPENDIX E
LABORATORY ANALYTICAL RESULTS
SOIL AND GROUNDWATER
ANALYTICAL REPORT
July 17, 2019
ATC Group Services - SC - Speedway
Sample Delivery Group:L1117537
Samples Received:07/11/2019
Project Number:0007956
Description:SW 7956 Fremont NC
Site:0007656 0-035993
Report To:Mr. Bob Bolton / Donald Hurdle
7499 Parklane Road, Suite 112
Columbia, SC 29223
Entire Report Reviewed By:
July 17, 2019
[Preliminary Report]
John Hawkins
Project Manager
Results relate only to the items tested or calibrated and are reported as rounded values. This test report shall not be reproduced, except in full, without written approval of the laboratory. Where applicable, sampling conducted by Pace Nationalis performed per guidance provided in laboratory standard operating procedures: 060302, 060303, and 060304.
12065 Lebanon Rd Mount Juliet, TN 37122 615-758-5858 800-767-5859 www.pacenational.com
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 1 of 15
July 17, 2019
John Hawkins
Project Manager
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 1 of 15
ONE LAB. NATIONWIDE.TABLE OF CONTENTS
Cp: Cover Page 1
Tc: Table of Contents 2
Ss: Sample Summary 3
Cn: Case Narrative 4
Sr: Sample Results 5
MW-01-SOIL L1117537-01 5
MW-02-SOIL L1117537-02 6
MW-03-SOIL L1117537-03 7
Qc: Quality Control Summary 8
Total Solids by Method 2540 G-2011 8
Volatile Petroleum Hydrocarbons by Method MADEPV 9
Volatile Organic Compounds (GC/MS) by Method 8260D 10
Gl: Glossary of Terms 11
Al: Accreditations & Locations 12
Sc: Sample Chain of Custody 13
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 2 of 15
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 2 of 15
ONE LAB. NATIONWIDE.SAMPLE SUMMARY
Collected by Collected date/time Received date/time
MW-01-SOIL L1117537-01 Solid Emily Fuller 07/08/19 16:45 07/11/19 08:45
Method Batch Dilution Preparation Analysis Analyst Location
date/time date/time
Total Solids by Method 2540 G-2011 WG1312078 1 07/16/19 12:48 07/16/19 13:04 KBC Mt. Juliet, TN
Volatile Petroleum Hydrocarbons by Method MADEPV WG1311504 68 07/16/19 22:38 07/16/19 22:38 ACG Mt. Juliet, TN
Volatile Organic Compounds (GC/MS) by Method 8260D WG1312055 1 07/08/19 16:45 07/16/19 17:22 JHH Mt. Juliet, TN
Collected by Collected date/time Received date/time
MW-02-SOIL L1117537-02 Solid Emily Fuller 07/09/19 09:45 07/11/19 08:45
Method Batch Dilution Preparation Analysis Analyst Location
date/time date/time
Total Solids by Method 2540 G-2011 WG1312078 1 07/16/19 12:48 07/16/19 13:04 KBC Mt. Juliet, TN
Volatile Petroleum Hydrocarbons by Method MADEPV WG1311504 50 07/16/19 23:12 07/16/19 23:12 ACG Mt. Juliet, TN
Volatile Organic Compounds (GC/MS) by Method 8260D WG1312055 1 07/09/19 09:45 07/16/19 17:40 JHH Mt. Juliet, TN
Collected by Collected date/time Received date/time
MW-03-SOIL L1117537-03 Solid Emily Fuller 07/08/19 17:35 07/11/19 08:45
Method Batch Dilution Preparation Analysis Analyst Location
date/time date/time
Total Solids by Method 2540 G-2011 WG1312078 1 07/16/19 12:48 07/16/19 13:04 KBC Mt. Juliet, TN
Volatile Petroleum Hydrocarbons by Method MADEPV WG1311504 50 07/16/19 23:45 07/16/19 23:45 ACG Mt. Juliet, TN
Volatile Organic Compounds (GC/MS) by Method 8260D WG1312055 1.01 07/08/19 17:35 07/16/19 17:59 JHH Mt. Juliet, TN
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 3 of 15
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 3 of 15
ONE LAB. NATIONWIDE.CASE NARRATIVE
All sample aliquots were received at the correct temperature, in the proper containers, with the
appropriate preservatives, and within method specified holding times, unless qualified or notated within
the report. Where applicable, all MDL (LOD) and RDL (LOQ) values reported for environmental samples
have been corrected for the dilution factor used in the analysis. All Method and Batch Quality Control
are within established criteria except where addressed in this case narrative, a non-conformance form
or properly qualified within the sample results. By my digital signature below, I affirm to the best of my
knowledge, all problems/anomalies observed by the laboratory as having the potential to affect the
quality of the data have been identified by the laboratory, and no information or data have been
knowingly withheld that would affect the quality of the data.
[Preliminary Report]
John Hawkins
Project Manager
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 4 of 15
John Hawkins
Project Manager
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 4 of 15
ONE LAB. NATIONWIDE.SAMPLE RESULTS - 01
L1117537
MW-01-SOIL
Collected date/time: 07/08/19 16:45
Total Solids by Method 2540 G-2011
Result Qualifier Dilution Analysis Batch
Analyte %date / time
Total Solids 87.3 1 07/16/2019 13:04 WG1312078
Volatile Petroleum Hydrocarbons by Method MADEPV
Result Qualifier RDL Dilution Analysis Batch
Analyte mg/kg mg/kg date / time
Unadjusted C5-C8 Aliphatics ND 6.80 68 07/16/2019 22:38 WG1311504
Unadjusted C9-C12 Aliphatics ND 6.80 68 07/16/2019 22:38 WG1311504
Unadjusted C9-C10 Aromatics ND 6.80 68 07/16/2019 22:38 WG1311504
Total VPH ND 6.80 68 07/16/2019 22:38 WG1311504
(S) 2,5-Dibromotoluene(FID)97.8 70.0-130 07/16/2019 22:38 WG1311504
(S) 2,5-Dibromotoluene(PID)91.6 70.0-130 07/16/2019 22:38 WG1311504
Volatile Organic Compounds (GC/MS) by Method 8260D
Result Qualifier RDL Dilution Analysis Batch
Analyte mg/kg mg/kg date / time
Benzene 0.00764 0.00100 1 07/16/2019 17:22 WG1312055
Toluene 0.0209 0.00500 1 07/16/2019 17:22 WG1312055
Ethylbenzene 0.0127 0.00250 1 07/16/2019 17:22 WG1312055
Total Xylenes 0.0380 0.00650 1 07/16/2019 17:22 WG1312055
Methyl tert-butyl ether ND 0.00100 1 07/16/2019 17:22 WG1312055
Naphthalene 0.0237 0.0125 1 07/16/2019 17:22 WG1312055
Di-isopropyl ether ND 0.00100 1 07/16/2019 17:22 WG1312055
(S) Toluene-d8 110 75.0-131 07/16/2019 17:22 WG1312055
(S) 4-Bromofluorobenzene 105 67.0-138 07/16/2019 17:22 WG1312055
(S) 1,2-Dichloroethane-d4 89.4 70.0-130 07/16/2019 17:22 WG1312055
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 5 of 15
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 5 of 15
ONE LAB. NATIONWIDE.SAMPLE RESULTS - 02
L1117537
MW-02-SOIL
Collected date/time: 07/09/19 09:45
Total Solids by Method 2540 G-2011
Result Qualifier Dilution Analysis Batch
Analyte %date / time
Total Solids 82.7 1 07/16/2019 13:04 WG1312078
Volatile Petroleum Hydrocarbons by Method MADEPV
Result Qualifier RDL Dilution Analysis Batch
Analyte mg/kg mg/kg date / time
Unadjusted C5-C8 Aliphatics ND 5.00 50 07/16/2019 23:12 WG1311504
Unadjusted C9-C12 Aliphatics ND 5.00 50 07/16/2019 23:12 WG1311504
Unadjusted C9-C10 Aromatics ND 5.00 50 07/16/2019 23:12 WG1311504
Total VPH ND 5.00 50 07/16/2019 23:12 WG1311504
(S) 2,5-Dibromotoluene(FID)99.4 70.0-130 07/16/2019 23:12 WG1311504
(S) 2,5-Dibromotoluene(PID)93.3 70.0-130 07/16/2019 23:12 WG1311504
Volatile Organic Compounds (GC/MS) by Method 8260D
Result Qualifier RDL Dilution Analysis Batch
Analyte mg/kg mg/kg date / time
Benzene ND 0.00100 1 07/16/2019 17:40 WG1312055
Toluene 0.0401 0.00500 1 07/16/2019 17:40 WG1312055
Ethylbenzene ND 0.00250 1 07/16/2019 17:40 WG1312055
Total Xylenes ND 0.00650 1 07/16/2019 17:40 WG1312055
Methyl tert-butyl ether ND 0.00100 1 07/16/2019 17:40 WG1312055
Naphthalene ND 0.0125 1 07/16/2019 17:40 WG1312055
Di-isopropyl ether ND 0.00100 1 07/16/2019 17:40 WG1312055
(S) Toluene-d8 110 75.0-131 07/16/2019 17:40 WG1312055
(S) 4-Bromofluorobenzene 103 67.0-138 07/16/2019 17:40 WG1312055
(S) 1,2-Dichloroethane-d4 88.3 70.0-130 07/16/2019 17:40 WG1312055
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 6 of 15
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 6 of 15
ONE LAB. NATIONWIDE.SAMPLE RESULTS - 03
L1117537
MW-03-SOIL
Collected date/time: 07/08/19 17:35
Total Solids by Method 2540 G-2011
Result Qualifier Dilution Analysis Batch
Analyte %date / time
Total Solids 81.3 1 07/16/2019 13:04 WG1312078
Volatile Petroleum Hydrocarbons by Method MADEPV
Result Qualifier RDL Dilution Analysis Batch
Analyte mg/kg mg/kg date / time
Unadjusted C5-C8 Aliphatics ND 5.00 50 07/16/2019 23:45 WG1311504
Unadjusted C9-C12 Aliphatics ND 5.00 50 07/16/2019 23:45 WG1311504
Unadjusted C9-C10 Aromatics ND 5.00 50 07/16/2019 23:45 WG1311504
Total VPH ND 5.00 50 07/16/2019 23:45 WG1311504
(S) 2,5-Dibromotoluene(FID)93.5 70.0-130 07/16/2019 23:45 WG1311504
(S) 2,5-Dibromotoluene(PID)87.4 70.0-130 07/16/2019 23:45 WG1311504
Volatile Organic Compounds (GC/MS) by Method 8260D
Result Qualifier RDL Dilution Analysis Batch
Analyte mg/kg mg/kg date / time
Benzene 0.00245 0.00101 1.01 07/16/2019 17:59 WG1312055
Toluene 0.0475 0.00505 1.01 07/16/2019 17:59 WG1312055
Ethylbenzene 0.0236 0.00253 1.01 07/16/2019 17:59 WG1312055
Total Xylenes 0.0107 0.00657 1.01 07/16/2019 17:59 WG1312055
Methyl tert-butyl ether 0.00106 0.00101 1.01 07/16/2019 17:59 WG1312055
Naphthalene 0.0803 0.0126 1.01 07/16/2019 17:59 WG1312055
Di-isopropyl ether ND 0.00101 1.01 07/16/2019 17:59 WG1312055
(S) Toluene-d8 109 75.0-131 07/16/2019 17:59 WG1312055
(S) 4-Bromofluorobenzene 105 67.0-138 07/16/2019 17:59 WG1312055
(S) 1,2-Dichloroethane-d4 89.5 70.0-130 07/16/2019 17:59 WG1312055
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 7 of 15
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 7 of 15
ONE LAB. NATIONWIDE.QUALITY CONTROL SUMMARYWG1312078
Total Solids by Method 2540 G-2011 L1117537-01,02,03
Method Blank (MB)
(MB) R3431396-1 07/16/19 13:04
MB Result MB Qualifier MB MDL MB RDL
Analyte %%%
Total Solids 0.000
L1117544-01 Original Sample (OS) • Duplicate (DUP)
(OS) L1117544-01 07/16/19 13:04 • (DUP) R3431396-3 07/16/19 13:04
Original Result DUP Result Dilution DUP RPD DUP Qualifier DUP RPD
Limits
Analyte %%%%
Total Solids 95.0 95.4 1 0.455 10
Laboratory Control Sample (LCS)
(LCS) R3431396-2 07/16/19 13:04
Spike Amount LCS Result LCS Rec.Rec. Limits LCS Qualifier
Analyte %%%%
Total Solids 50.0 50.0 100 85.0-115
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 8 of 15
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 8 of 15
ONE LAB. NATIONWIDE.QUALITY CONTROL SUMMARYWG1311504
Volatile Petroleum Hydrocarbons by Method MADEPV L1117537-01,02,03
Method Blank (MB)
(MB) R3431378-3 07/16/19 15:37
MB Result MB Qualifier MB MDL MB RDL
Analyte mg/kg mg/kg mg/kg
Unadjusted C5-C8 Aliphatics U 1.67 5.00
Unadjusted C9-C12 Aliphatics U 1.67 5.00
Unadjusted C9-C10 Aromatics U 1.67 5.00
Total VPH 2.82 J 1.67 5.00
(S) 2,5-Dibromotoluene(FID)88.5 70.0-130
(S) 2,5-Dibromotoluene(PID)84.4 70.0-130
Laboratory Control Sample (LCS) • Laboratory Control Sample Duplicate (LCSD)
(LCS) R3431378-1 07/16/19 12:52 • (LCSD) R3431378-2 07/16/19 13:25
Spike Amount LCS Result LCSD Result LCS Rec.LCSD Rec.Rec. Limits LCS Qualifier LCSD Qualifier RPD RPD Limits
Analyte mg/kg mg/kg mg/kg %%%%%
Unadjusted C5-C8 Aliphatics 1.20 1.39 1.39 116 116 70.0-130 0.342 25
Unadjusted C9-C12 Aliphatics 1.40 1.73 1.71 124 122 70.0-130 1.51 25
Unadjusted C9-C10 Aromatics 0.200 0.217 0.213 109 106 70.0-130 2.13 25
Total VPH 2.80 3.34 3.31 119 118 70.0-130 0.722 25
(S) 2,5-Dibromotoluene(FID) 92.3 94.6 70.0-130
(S) 2,5-Dibromotoluene(PID) 89.0 92.1 70.0-130
L1117469-01 Original Sample (OS) • Matrix Spike (MS) • Matrix Spike Duplicate (MSD)
(OS) L1117469-01 07/16/19 16:35 • (MS) R3431378-4 07/17/19 01:57 • (MSD) R3431378-5 07/17/19 02:30
Spike Amount
(dry)
Original Result
(dry)MS Result (dry)MSD Result
(dry)MS Rec.MSD Rec.Dilution Rec. Limits MS Qualifier MSD Qualifier RPD RPD Limits
Analyte mg/kg mg/kg mg/kg mg/kg %%%%%
Unadjusted C5-C8 Aliphatics 1.38 U 80.4 174 41.3 89.5 141 70.0-130 J6 J3 73.7 25
Unadjusted C9-C12 Aliphatics 1.61 U 113 265 49.6 117 141 70.0-130 J6 J3 80.6 25
Unadjusted C9-C10 Aromatics 0.230 U 17.2 34.1 53.1 105 141 70.0-130 J6 J3 65.8 25
Total VPH 3.22 U 210 472 46.3 104 141 70.0-130 J6 J3 76.8 25
(S) 2,5-Dibromotoluene(FID) 91.5 94.6 70.0-130
(S) 2,5-Dibromotoluene(PID) 86.0 89.4 70.0-130
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 9 of 15
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 9 of 15
ONE LAB. NATIONWIDE.QUALITY CONTROL SUMMARYWG1312055
Volatile Organic Compounds (GC/MS) by Method 8260D L1117537-01,02,03
Method Blank (MB)
(MB) R3431195-2 07/16/19 08:10
MB Result MB Qualifier MB MDL MB RDL
Analyte mg/kg mg/kg mg/kg
Benzene U 0.000400 0.00100
Di-isopropyl ether U 0.000350 0.00100
Ethylbenzene U 0.000530 0.00250
Methyl tert-butyl ether U 0.000295 0.00100
Naphthalene U 0.00312 0.0125
Toluene U 0.00125 0.00500
Xylenes, Total U 0.00478 0.00650
(S) Toluene-d8 108 75.0-131
(S) 4-Bromofluorobenzene 103 67.0-138
(S) 1,2-Dichloroethane-d4 89.2 70.0-130
Laboratory Control Sample (LCS)
(LCS) R3431195-1 07/16/19 07:14
Spike Amount LCS Result LCS Rec.Rec. Limits LCS Qualifier
Analyte mg/kg mg/kg %%
Benzene 0.125 0.106 85.1 70.0-123
Di-isopropyl ether 0.125 0.114 91.0 60.0-136
Ethylbenzene 0.125 0.123 98.6 74.0-126
Methyl tert-butyl ether 0.125 0.151 121 66.0-132
Naphthalene 0.125 0.109 87.4 59.0-130
Toluene 0.125 0.113 90.3 75.0-121
Xylenes, Total 0.375 0.316 84.3 72.0-127
(S) Toluene-d8 108 75.0-131
(S) 4-Bromofluorobenzene 106 67.0-138
(S) 1,2-Dichloroethane-d4 103 70.0-130
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 10 of 15
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 10 of 15
ONE LAB. NATIONWIDE.GLOSSARY OF TERMS
Guide to Reading and Understanding Your Laboratory Report
The information below is designed to better explain the various terms used in your report of analytical results from the Laboratory. This is not
intended as a comprehensive explanation, and if you have additional questions please contact your project representative.
Abbreviations and Definitions
(dry)Results are reported based on the dry weight of the sample. [this will only be present on a dry report basis for soils].
MDL Method Detection Limit.
ND Not detected at the Reporting Limit (or MDL where applicable).
RDL Reported Detection Limit.
Rec.Recovery.
RPD Relative Percent Difference.
SDG Sample Delivery Group.
(S)
Surrogate (Surrogate Standard) - Analytes added to every blank, sample, Laboratory Control Sample/Duplicate and
Matrix Spike/Duplicate; used to evaluate analytical efficiency by measuring recovery. Surrogates are not expected to be
detected in all environmental media.
U Not detected at the Reporting Limit (or MDL where applicable).
Analyte The name of the particular compound or analysis performed. Some Analyses and Methods will have multiple analytes
reported.
Dilution
If the sample matrix contains an interfering material, the sample preparation volume or weight values differ from the
standard, or if concentrations of analytes in the sample are higher than the highest limit of concentration that the
laboratory can accurately report, the sample may be diluted for analysis. If a value different than 1 is used in this field, the
result reported has already been corrected for this factor.
Limits
These are the target % recovery ranges or % difference value that the laboratory has historically determined as normal
for the method and analyte being reported. Successful QC Sample analysis will target all analytes recovered or
duplicated within these ranges.
Original Sample The non-spiked sample in the prep batch used to determine the Relative Percent Difference (RPD) from a quality control
sample. The Original Sample may not be included within the reported SDG.
Qualifier
This column provides a letter and/or number designation that corresponds to additional information concerning the result
reported. If a Qualifier is present, a definition per Qualifier is provided within the Glossary and Definitions page and
potentially a discussion of possible implications of the Qualifier in the Case Narrative if applicable.
Result
The actual analytical final result (corrected for any sample specific characteristics) reported for your sample. If there was
no measurable result returned for a specific analyte, the result in this column may state “ND” (Not Detected) or “BDL”
(Below Detectable Levels). The information in the results column should always be accompanied by either an MDL
(Method Detection Limit) or RDL (Reporting Detection Limit) that defines the lowest value that the laboratory could detect
or report for this analyte.
Uncertainty
(Radiochemistry)Confidence level of 2 sigma.
Case Narrative (Cn)
A brief discussion about the included sample results, including a discussion of any non-conformances to protocol
observed either at sample receipt by the laboratory from the field or during the analytical process. If present, there will
be a section in the Case Narrative to discuss the meaning of any data qualifiers used in the report.
Quality Control
Summary (Qc)
This section of the report includes the results of the laboratory quality control analyses required by procedure or
analytical methods to assist in evaluating the validity of the results reported for your samples. These analyses are not
being performed on your samples typically, but on laboratory generated material.
Sample Chain of
Custody (Sc)
This is the document created in the field when your samples were initially collected. This is used to verify the time and
date of collection, the person collecting the samples, and the analyses that the laboratory is requested to perform. This
chain of custody also documents all persons (excluding commercial shippers) that have had control or possession of the
samples from the time of collection until delivery to the laboratory for analysis.
Sample Results (Sr)
This section of your report will provide the results of all testing performed on your samples. These results are provided
by sample ID and are separated by the analyses performed on each sample. The header line of each analysis section for
each sample will provide the name and method number for the analysis reported.
Sample Summary (Ss)This section of the Analytical Report defines the specific analyses performed for each sample ID, including the dates and
times of preparation and/or analysis.
Qualifier Description
J The identification of the analyte is acceptable; the reported value is an estimate.
J3 The associated batch QC was outside the established quality control range for precision.
J6 The sample matrix interfered with the ability to make any accurate determination; spike value is low.
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 11 of 15
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 11 of 15
ONE LAB. NATIONWIDE.
Pace National is the only environmental laboratory accredited/certified to support your work nationwide from one location. One phone call, one point of contact, one laboratory. No other lab is as
accessible or prepared to handle your needs throughout the country. Our capacity and capability from our single location laboratory is comparable to the collective totals of the network
laboratories in our industry. The most significant benefit to our one location design is the design of our laboratory campus. The model is conducive to accelerated productivity, decreasing
turn-around time, and preventing cross contamination, thus protecting sample integrity. Our focus on premium quality and prompt service allows us to be YOUR LAB OF CHOICE.
* Not all certifications held by the laboratory are applicable to the results reported in the attached report.
* Accreditation is only applicable to the test methods specified on each scope of accreditation held by Pace National.
State Accreditations
Alabama 40660 Nebraska NE-OS-15-05
Alaska 17-026 Nevada TN-03-2002-34
Arizona AZ0612 New Hampshire 2975
Arkansas 88-0469 New Jersey–NELAP TN002
California 2932 New Mexico ¹n/a
Colorado TN00003 New York 11742
Connecticut PH-0197 North Carolina Env375
Florida E87487 North Carolina ¹DW21704
Georgia NELAP North Carolina ³41
Georgia ¹923 North Dakota R-140
Idaho TN00003 Ohio–VAP CL0069
Illinois 200008 Oklahoma 9915
Indiana C-TN-01 Oregon TN200002
Iowa 364 Pennsylvania 68-02979
Kansas E-10277 Rhode Island LAO00356
Kentucky ¹ ⁶90010 South Carolina 84004
Kentucky ²16 South Dakota n/a
Louisiana AI30792 Tennessee ¹ ⁴2006
Louisiana ¹LA180010 Texas T104704245-18-15
Maine TN0002 Texas ⁵LAB0152
Maryland 324 Utah TN00003
Massachusetts M-TN003 Vermont VT2006
Michigan 9958 Virginia 460132
Minnesota 047-999-395 Washington C847
Mississippi TN00003 West Virginia 233
Missouri 340 Wisconsin 9980939910
Montana CERT0086 Wyoming A2LA
Third Party Federal Accreditations
A2LA – ISO 17025 1461.01 AIHA-LAP,LLC EMLAP 100789
A2LA – ISO 17025 ⁵1461.02 DOD 1461.01
Canada 1461.01 USDA P330-15-00234
EPA–Crypto TN00003
ACCREDITATIONS & LOCATIONS
¹ Drinking Water ² Underground Storage Tanks ³ Aquatic Toxicity ⁴ Chemical/Microbiological ⁵ Mold ⁶ Wastewater n/a Accreditation not applicable
Our Locations
Pace National has sixty-four client support centers that provide sample pickup and/or the delivery of sampling supplies. If you would like assistance from one of our support offices, please contactour main office. Pace National performs all testing at our central laboratory.
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 12:53 12 of 15
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1117537 07/17/19 17:12 12 of 15
ANALYTICAL REPORT
July 25, 2019
ATC Group Services - SC - Speedway
Sample Delivery Group:L1120024
Samples Received:07/18/2019
Project Number:0007956
Description:SW 7956 Fremont NC
Site:0007956 0-035993
Report To:Mr. Bob Bolton / Donald Hurdle
7499 Parklane Road, Suite 112
Columbia, SC 29223
Entire Report Reviewed By:
July 25, 2019
[Preliminary Report]
John Hawkins
Project Manager
Results relate only to the items tested or calibrated and are reported as rounded values. This test report shall not be reproduced, except in full, without written approval of the laboratory. Where applicable, sampling conducted by Pace Analytical National is performed per guidance provided in laboratory standard operating procedures ENV-SOP-MTJL-0067 and ENV-SOP-MTJL-0068. Where sampling conducted by the customer, results relate to the accuracy of the information provided, and as the samples are received.
12065 Lebanon Rd Mount Juliet, TN 37122 615-758-5858 800-767-5859 www.pacenational.com
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 1 of 17
July 26, 2019
John Hawkins
Project Manager
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 1 of 17
ONE LAB. NATIONWIDE.TABLE OF CONTENTS
Cp: Cover Page 1
Tc: Table of Contents 2
Ss: Sample Summary 3
Cn: Case Narrative 4
Sr: Sample Results 5
MW-01 L1120024-01 5
MW-02 L1120024-02 6
MW-03 L1120024-03 7
Qc: Quality Control Summary 8
Metals (ICP) by Method 6010D 8
Volatile Petroleum Hydrocarbons by Method MADEPV 9
Volatile Organic Compounds (GC/MS) by Method 6200B-1997/6200B-2011 10
Volatile Organic Compounds (GC/MS) by Method 6200B-2011 11
EDB / DBCP by Method 504.1 12
Gl: Glossary of Terms 13
Al: Accreditations & Locations 14
Sc: Sample Chain of Custody 15
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 2 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 2 of 17
ONE LAB. NATIONWIDE.SAMPLE SUMMARY
Collected by Collected date/time Received date/time
MW-01 L1120024-01 GW Carter Paradis 07/16/19 09:15 07/18/19 08:45
Method Batch Dilution Preparation Analysis Analyst Location
date/time date/time
Metals (ICP) by Method 6010D WG1314689 1 07/22/19 08:17 07/24/19 06:07 TRB Mt. Juliet, TN
Volatile Petroleum Hydrocarbons by Method MADEPV WG1315598 10 07/24/19 15:05 07/24/19 15:05 ACG Mt. Juliet, TN
Volatile Organic Compounds (GC/MS) by Method 6200B-1997/6200B-2011 WG1316933 50 07/25/19 14:23 07/25/19 14:23 ADM Mt. Juliet, TN
Volatile Organic Compounds (GC/MS) by Method 6200B-2011 WG1314714 10 07/20/19 10:10 07/20/19 10:10 ZJM Mt. Juliet, TN
EDB / DBCP by Method 504.1 WG1315233 1 07/22/19 09:04 07/22/19 18:45 HMH Mt. Juliet, TN
Collected by Collected date/time Received date/time
MW-02 L1120024-02 GW Carter Paradis 07/16/19 10:00 07/18/19 08:45
Method Batch Dilution Preparation Analysis Analyst Location
date/time date/time
Metals (ICP) by Method 6010D WG1314689 1 07/22/19 08:17 07/24/19 06:10 TRB Mt. Juliet, TN
Volatile Petroleum Hydrocarbons by Method MADEPV WG1315598 10 07/24/19 15:44 07/24/19 15:44 ACG Mt. Juliet, TN
Volatile Organic Compounds (GC/MS) by Method 6200B-1997/6200B-2011 WG1316933 50 07/25/19 14:43 07/25/19 14:43 ADM Mt. Juliet, TN
Volatile Organic Compounds (GC/MS) by Method 6200B-2011 WG1314714 10 07/20/19 10:30 07/20/19 10:30 ZJM Mt. Juliet, TN
EDB / DBCP by Method 504.1 WG1315233 1 07/22/19 09:04 07/22/19 18:57 HMH Mt. Juliet, TN
Collected by Collected date/time Received date/time
MW-03 L1120024-03 GW Carter Paradis 07/16/19 10:45 07/18/19 08:45
Method Batch Dilution Preparation Analysis Analyst Location
date/time date/time
Metals (ICP) by Method 6010D WG1314689 1 07/22/19 08:17 07/24/19 06:13 TRB Mt. Juliet, TN
Volatile Petroleum Hydrocarbons by Method MADEPV WG1315598 10 07/24/19 16:23 07/24/19 16:23 ACG Mt. Juliet, TN
Volatile Organic Compounds (GC/MS) by Method 6200B-1997/6200B-2011 WG1316933 20 07/25/19 15:03 07/25/19 15:03 ADM Mt. Juliet, TN
Volatile Organic Compounds (GC/MS) by Method 6200B-2011 WG1316933 50 07/25/19 17:57 07/25/19 17:57 BMB Mt. Juliet, TN
EDB / DBCP by Method 504.1 WG1315233 1 07/22/19 09:04 07/22/19 19:09 HMH Mt. Juliet, TN
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 3 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 3 of 17
ONE LAB. NATIONWIDE.CASE NARRATIVE
All sample aliquots were received at the correct temperature, in the proper containers, with the
appropriate preservatives, and within method specified holding times, unless qualified or notated within
the report. Where applicable, all MDL (LOD) and RDL (LOQ) values reported for environmental samples
have been corrected for the dilution factor used in the analysis. All Method and Batch Quality Control
are within established criteria except where addressed in this case narrative, a non-conformance form
or properly qualified within the sample results. By my digital signature below, I affirm to the best of my
knowledge, all problems/anomalies observed by the laboratory as having the potential to affect the
quality of the data have been identified by the laboratory, and no information or data have been
knowingly withheld that would affect the quality of the data.
[Preliminary Report]
John Hawkins
Project Manager
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 4 of 17
John Hawkins
Project Manager
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 4 of 17
ONE LAB. NATIONWIDE.SAMPLE RESULTS - 01
L1120024
MW-01
Collected date/time: 07/16/19 09:15
Metals (ICP) by Method 6010D
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Lead 116 1.90 5.00 1 07/24/2019 06:07 WG1314689
Volatile Petroleum Hydrocarbons by Method MADEPV
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Unadjusted C5-C8 Aliphatics 17000 333 1000 10 07/24/2019 15:05 WG1315598
Unadjusted C9-C12 Aliphatics 12700 333 1000 10 07/24/2019 15:05 WG1315598
Unadjusted C9-C10 Aromatics 3460 B 333 1000 10 07/24/2019 15:05 WG1315598
Total VPH 33200 333 1000 10 07/24/2019 15:05 WG1315598
(S) 2,5-Dibromotoluene(FID)106 70.0-130 07/24/2019 15:05 WG1315598
(S) 2,5-Dibromotoluene(PID)105 70.0-130 07/24/2019 15:05 WG1315598
Volatile Organic Compounds (GC/MS) by Method 6200B-1997/6200B-2011
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Benzene 132 3.31 10.0 10 07/20/2019 10:10 WG1314714
Ethylbenzene 1610 3.84 10.0 10 07/20/2019 10:10 WG1314714
1,2-Dichloroethane U 3.61 10.0 10 07/20/2019 10:10 WG1314714
Naphthalene 388 10.0 50.0 10 07/20/2019 10:10 WG1314714
Toluene 4880 20.6 50.0 50 07/25/2019 14:23 WG1316933
Methyl tert-butyl ether U 3.67 10.0 10 07/20/2019 10:10 WG1314714
Xylenes, Total 5660 53.0 150 50 07/25/2019 14:23 WG1316933
Di-isopropyl ether U 3.20 10.0 10 07/20/2019 10:10 WG1314714
(S) Toluene-d8 110 80.0-120 07/20/2019 10:10 WG1314714
(S) Toluene-d8 107 80.0-120 07/25/2019 14:23 WG1316933
(S) 4-Bromofluorobenzene 96.4 77.0-126 07/20/2019 10:10 WG1314714
(S) 4-Bromofluorobenzene 98.0 77.0-126 07/25/2019 14:23 WG1316933
(S) 1,2-Dichloroethane-d4 89.8 70.0-130 07/20/2019 10:10 WG1314714
(S) 1,2-Dichloroethane-d4 106 70.0-130 07/25/2019 14:23 WG1316933
EDB / DBCP by Method 504.1
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Ethylene Dibromide 0.0613 P 0.00240 0.0100 1 07/22/2019 18:45 WG1315233
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 5 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 5 of 17
ONE LAB. NATIONWIDE.SAMPLE RESULTS - 02
L1120024
MW-02
Collected date/time: 07/16/19 10:00
Metals (ICP) by Method 6010D
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Lead 78.9 1.90 5.00 1 07/24/2019 06:10 WG1314689
Volatile Petroleum Hydrocarbons by Method MADEPV
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Unadjusted C5-C8 Aliphatics 14500 333 1000 10 07/24/2019 15:44 WG1315598
Unadjusted C9-C12 Aliphatics 17600 333 1000 10 07/24/2019 15:44 WG1315598
Unadjusted C9-C10 Aromatics 5830 333 1000 10 07/24/2019 15:44 WG1315598
Total VPH 37900 333 1000 10 07/24/2019 15:44 WG1315598
(S) 2,5-Dibromotoluene(FID)106 70.0-130 07/24/2019 15:44 WG1315598
(S) 2,5-Dibromotoluene(PID)105 70.0-130 07/24/2019 15:44 WG1315598
Volatile Organic Compounds (GC/MS) by Method 6200B-1997/6200B-2011
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Benzene 123 3.31 10.0 10 07/20/2019 10:30 WG1314714
Ethylbenzene 2010 19.2 50.0 50 07/25/2019 14:43 WG1316933
1,2-Dichloroethane U 3.61 10.0 10 07/20/2019 10:30 WG1314714
Naphthalene 571 10.0 50.0 10 07/20/2019 10:30 WG1314714
Toluene 1690 4.12 10.0 10 07/20/2019 10:30 WG1314714
Methyl tert-butyl ether U 3.67 10.0 10 07/20/2019 10:30 WG1314714
Xylenes, Total 6890 53.0 150 50 07/25/2019 14:43 WG1316933
Di-isopropyl ether U 3.20 10.0 10 07/20/2019 10:30 WG1314714
(S) Toluene-d8 107 80.0-120 07/20/2019 10:30 WG1314714
(S) Toluene-d8 105 80.0-120 07/25/2019 14:43 WG1316933
(S) 4-Bromofluorobenzene 95.5 77.0-126 07/20/2019 10:30 WG1314714
(S) 4-Bromofluorobenzene 97.5 77.0-126 07/25/2019 14:43 WG1316933
(S) 1,2-Dichloroethane-d4 90.6 70.0-130 07/20/2019 10:30 WG1314714
(S) 1,2-Dichloroethane-d4 106 70.0-130 07/25/2019 14:43 WG1316933
EDB / DBCP by Method 504.1
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Ethylene Dibromide U 0.00240 0.0100 1 07/22/2019 18:57 WG1315233
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 6 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 6 of 17
ONE LAB. NATIONWIDE.SAMPLE RESULTS - 03
L1120024
MW-03
Collected date/time: 07/16/19 10:45
Metals (ICP) by Method 6010D
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Lead 26.0 1.90 5.00 1 07/24/2019 06:13 WG1314689
Volatile Petroleum Hydrocarbons by Method MADEPV
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Unadjusted C5-C8 Aliphatics 14700 333 1000 10 07/24/2019 16:23 WG1315598
Unadjusted C9-C12 Aliphatics 10900 333 1000 10 07/24/2019 16:23 WG1315598
Unadjusted C9-C10 Aromatics 2910 B 333 1000 10 07/24/2019 16:23 WG1315598
Total VPH 28500 333 1000 10 07/24/2019 16:23 WG1315598
(S) 2,5-Dibromotoluene(FID)104 70.0-130 07/24/2019 16:23 WG1315598
(S) 2,5-Dibromotoluene(PID)105 70.0-130 07/24/2019 16:23 WG1315598
Volatile Organic Compounds (GC/MS) by Method 6200B-1997/6200B-2011
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Benzene 266 6.62 20.0 20 07/25/2019 15:03 WG1316933
Ethylbenzene 1050 7.68 20.0 20 07/25/2019 15:03 WG1316933
1,2-Dichloroethane U 7.22 20.0 20 07/25/2019 15:03 WG1316933
Naphthalene 277 20.0 100 20 07/25/2019 15:03 WG1316933
Toluene 4970 20.6 50.0 50 07/25/2019 17:57 WG1316933
Methyl tert-butyl ether U 7.34 20.0 20 07/25/2019 15:03 WG1316933
Xylenes, Total 4940 21.2 60.0 20 07/25/2019 15:03 WG1316933
Di-isopropyl ether U 6.40 20.0 20 07/25/2019 15:03 WG1316933
(S) Toluene-d8 108 80.0-120 07/25/2019 17:57 WG1316933
(S) Toluene-d8 108 80.0-120 07/25/2019 15:03 WG1316933
(S) 4-Bromofluorobenzene 96.7 77.0-126 07/25/2019 15:03 WG1316933
(S) 4-Bromofluorobenzene 99.1 77.0-126 07/25/2019 17:57 WG1316933
(S) 1,2-Dichloroethane-d4 104 70.0-130 07/25/2019 17:57 WG1316933
(S) 1,2-Dichloroethane-d4 106 70.0-130 07/25/2019 15:03 WG1316933
EDB / DBCP by Method 504.1
Result Qualifier MDL RDL Dilution Analysis Batch
Analyte ug/l ug/l ug/l date / time
Ethylene Dibromide 0.118 0.00240 0.0100 1 07/22/2019 19:09 WG1315233
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 7 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 7 of 17
ONE LAB. NATIONWIDE.QUALITY CONTROL SUMMARYWG1314689
Metals (ICP) by Method 6010D L1120024-01,02,03
Method Blank (MB)
(MB) R3433564-1 07/24/19 05:48
MB Result MB Qualifier MB MDL MB RDL
Analyte ug/l ug/l ug/l
Lead U 1.90 5.00
Laboratory Control Sample (LCS) • Laboratory Control Sample Duplicate (LCSD)
(LCS) R3433564-2 07/24/19 05:51 • (LCSD) R3433564-3 07/24/19 05:53
Spike Amount LCS Result LCSD Result LCS Rec.LCSD Rec.Rec. Limits LCS Qualifier LCSD Qualifier RPD RPD Limits
Analyte ug/l ug/l ug/l %%%%%
Lead 1000 996 1010 99.6 101 80.0-120 1.84 20
L1120585-05 Original Sample (OS) • Matrix Spike (MS) • Matrix Spike Duplicate (MSD)
(OS) L1120585-05 07/24/19 05:56 • (MS) R3433564-5 07/24/19 06:02 • (MSD) R3433564-6 07/24/19 06:05
Spike Amount Original Result MS Result MSD Result MS Rec.MSD Rec.Dilution Rec. Limits MS Qualifier MSD Qualifier RPD RPD Limits
Analyte ug/l ug/l ug/l ug/l %%%%%
Lead 1000 U 984 986 98.4 98.6 1 75.0-125 0.217 20
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 8 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 8 of 17
ONE LAB. NATIONWIDE.QUALITY CONTROL SUMMARYWG1315598
Volatile Petroleum Hydrocarbons by Method MADEPV L1120024-01,02,03
Method Blank (MB)
(MB) R3434125-3 07/24/19 14:25
MB Result MB Qualifier MB MDL MB RDL
Analyte ug/l ug/l ug/l
Unadjusted C5-C8 Aliphatics U 33.3 100
Unadjusted C9-C12 Aliphatics U 33.3 100
Unadjusted C9-C10 Aromatics 43.2 J 33.3 100
Total VPH U 33.3 100
(S) 2,5-Dibromotoluene(FID)96.2 70.0-130
(S) 2,5-Dibromotoluene(PID)99.6 70.0-130
Laboratory Control Sample (LCS) • Laboratory Control Sample Duplicate (LCSD)
(LCS) R3434125-1 07/24/19 11:49 • (LCSD) R3434125-2 07/24/19 12:28
Spike Amount LCS Result LCSD Result LCS Rec.LCSD Rec.Rec. Limits LCS Qualifier LCSD Qualifier RPD RPD Limits
Analyte ug/l ug/l ug/l %%%%%
Unadjusted C5-C8 Aliphatics 1200 1150 1210 96.1 101 70.0-130 4.84 25
Unadjusted C9-C12 Aliphatics 1400 1580 1690 113 121 70.0-130 6.66 25
Unadjusted C9-C10 Aromatics 200 228 229 114 115 70.0-130 0.790 25
Total VPH 2800 2960 3130 106 112 70.0-130 5.62 25
(S) 2,5-Dibromotoluene(FID) 102 101 70.0-130
(S) 2,5-Dibromotoluene(PID) 107 107 70.0-130
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 9 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 9 of 17
ONE LAB. NATIONWIDE.QUALITY CONTROL SUMMARYWG1316933
Volatile Organic Compounds (GC/MS) by Method 6200B-1997/6200B-2011 L1120024-01,02,03
Method Blank (MB)
(MB) R3434363-4 07/25/19 11:26
MB Result MB Qualifier MB MDL MB RDL
Analyte ug/l ug/l ug/l
Benzene U 0.331 1.00
1,2-Dichloroethane U 0.361 1.00
Di-isopropyl ether U 0.320 1.00
Ethylbenzene U 0.384 1.00
Methyl tert-butyl ether U 0.367 1.00
Naphthalene U 1.00 5.00
Toluene U 0.412 1.00
Xylenes, Total U 1.06 3.00
(S) Toluene-d8 108 80.0-120
(S) 4-Bromofluorobenzene 97.0 77.0-126
(S) 1,2-Dichloroethane-d4 104 70.0-130
Laboratory Control Sample (LCS) • Laboratory Control Sample Duplicate (LCSD)
(LCS) R3434363-1 07/25/19 10:06 • (LCSD) R3434363-2 07/25/19 10:26
Spike Amount LCS Result LCSD Result LCS Rec.LCSD Rec.Rec. Limits LCS Qualifier LCSD Qualifier RPD RPD Limits
Analyte ug/l ug/l ug/l %%%%%
Benzene 25.0 23.1 23.0 92.3 92.0 70.0-123 0.284 20
1,2-Dichloroethane 25.0 23.0 23.3 92.0 93.1 70.0-128 1.08 20
Di-isopropyl ether 25.0 24.6 24.9 98.5 99.6 58.0-138 1.18 20
Ethylbenzene 25.0 24.5 24.1 98.1 96.5 79.0-123 1.68 20
Methyl tert-butyl ether 25.0 19.3 19.3 77.4 77.3 68.0-125 0.0971 20
Naphthalene 25.0 22.4 22.6 89.7 90.2 54.0-135 0.562 20
Toluene 25.0 23.5 23.2 94.1 92.7 79.0-120 1.43 20
Xylenes, Total 75.0 70.0 70.0 93.3 93.3 79.0-123 0.000 20
(S) Toluene-d8 108 106 80.0-120
(S) 4-Bromofluorobenzene 99.5 99.3 77.0-126
(S) 1,2-Dichloroethane-d4 108 107 70.0-130
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 10 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 10 of 17
ONE LAB. NATIONWIDE.QUALITY CONTROL SUMMARYWG1314714
Volatile Organic Compounds (GC/MS) by Method 6200B-2011 L1120024-01,02
Method Blank (MB)
(MB) R3433458-3 07/20/19 03:35
MB Result MB Qualifier MB MDL MB RDL
Analyte ug/l ug/l ug/l
Benzene U 0.331 1.00
1,2-Dichloroethane U 0.361 1.00
Di-isopropyl ether U 0.320 1.00
Ethylbenzene U 0.384 1.00
Methyl tert-butyl ether U 0.367 1.00
Naphthalene U 1.00 5.00
Toluene U 0.412 1.00
(S) Toluene-d8 108 80.0-120
(S) 4-Bromofluorobenzene 98.4 77.0-126
(S) 1,2-Dichloroethane-d4 91.0 70.0-130
Laboratory Control Sample (LCS) • Laboratory Control Sample Duplicate (LCSD)
(LCS) R3433458-1 07/20/19 02:35 • (LCSD) R3433458-2 07/20/19 02:55
Spike Amount LCS Result LCSD Result LCS Rec.LCSD Rec.Rec. Limits LCS Qualifier LCSD Qualifier RPD RPD Limits
Analyte ug/l ug/l ug/l %%%%%
Benzene 25.0 23.2 24.0 92.7 95.8 70.0-123 3.30 20
1,2-Dichloroethane 25.0 21.0 21.4 83.9 85.7 70.0-128 2.10 20
Di-isopropyl ether 25.0 23.6 23.6 94.5 94.2 58.0-138 0.265 20
Ethylbenzene 25.0 25.0 25.9 99.8 103 79.0-123 3.54 20
Methyl tert-butyl ether 25.0 23.5 23.8 94.2 95.1 68.0-125 1.02 20
Naphthalene 25.0 20.4 22.8 81.7 91.3 54.0-135 11.2 20
Toluene 25.0 25.4 26.3 102 105 79.0-120 3.40 20
(S) Toluene-d8 108 108 80.0-120
(S) 4-Bromofluorobenzene 99.5 99.4 77.0-126
(S) 1,2-Dichloroethane-d4 96.1 95.9 70.0-130
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 11 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 11 of 17
ONE LAB. NATIONWIDE.QUALITY CONTROL SUMMARYWG1315233
EDB / DBCP by Method 504.1 L1120024-01,02,03
Method Blank (MB)
(MB) R3433470-1 07/22/19 17:19
MB Result MB Qualifier MB MDL MB RDL
Analyte ug/l ug/l ug/l
Ethylene Dibromide U 0.00240 0.0100
L1119916-02 Original Sample (OS) • Duplicate (DUP)
(OS) L1119916-02 07/22/19 18:08 • (DUP) R3433470-3 07/22/19 17:56
Original Result DUP Result Dilution DUP RPD DUP Qualifier DUP RPD
Limits
Analyte ug/l ug/l %%
Ethylene Dibromide ND 0.000 1 0.000 20
Laboratory Control Sample (LCS) • Laboratory Control Sample Duplicate (LCSD)
(LCS) R3433470-4 07/22/19 20:11 • (LCSD) R3433470-5 07/22/19 22:14
Spike Amount LCS Result LCSD Result LCS Rec.LCSD Rec.Rec. Limits LCS Qualifier LCSD Qualifier RPD RPD Limits
Analyte ug/l ug/l ug/l %%%%%
Ethylene Dibromide 0.250 0.259 0.243 104 97.2 70.0-130 6.37 20
Laboratory Control Sample (LCS)
(LCS) R3433898-1 07/24/19 14:58
Spike Amount LCS Result LCS Rec.Rec. Limits LCS Qualifier
Analyte ug/l ug/l %%
Ethylene Dibromide 0.250 0.258 103 70.0-130
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 12 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 12 of 17
ONE LAB. NATIONWIDE.GLOSSARY OF TERMS
Guide to Reading and Understanding Your Laboratory Report
The information below is designed to better explain the various terms used in your report of analytical results from the Laboratory. This is not
intended as a comprehensive explanation, and if you have additional questions please contact your project representative.
Results Disclaimer - Information that may be provided by the customer, and contained within this report, include Permit Limits, Project Name,
Sample ID, Sample Matrix, Sample Preservation, Field Blanks, Field Spikes, Field Duplicates, On-Site Data, Sampling Collection Dates/Times, and
Sampling Location. Results relate to the accuracy of this information provided, and as the samples are received.
Abbreviations and Definitions
MDL Method Detection Limit.
ND Not detected at the Reporting Limit (or MDL where applicable).
RDL Reported Detection Limit.
Rec.Recovery.
RPD Relative Percent Difference.
SDG Sample Delivery Group.
(S)
Surrogate (Surrogate Standard) - Analytes added to every blank, sample, Laboratory Control Sample/Duplicate and
Matrix Spike/Duplicate; used to evaluate analytical efficiency by measuring recovery. Surrogates are not expected to be
detected in all environmental media.
U Not detected at the Reporting Limit (or MDL where applicable).
Analyte The name of the particular compound or analysis performed. Some Analyses and Methods will have multiple analytes
reported.
Dilution
If the sample matrix contains an interfering material, the sample preparation volume or weight values differ from the
standard, or if concentrations of analytes in the sample are higher than the highest limit of concentration that the
laboratory can accurately report, the sample may be diluted for analysis. If a value different than 1 is used in this field, the
result reported has already been corrected for this factor.
Limits
These are the target % recovery ranges or % difference value that the laboratory has historically determined as normal
for the method and analyte being reported. Successful QC Sample analysis will target all analytes recovered or
duplicated within these ranges.
Original Sample The non-spiked sample in the prep batch used to determine the Relative Percent Difference (RPD) from a quality control
sample. The Original Sample may not be included within the reported SDG.
Qualifier
This column provides a letter and/or number designation that corresponds to additional information concerning the result
reported. If a Qualifier is present, a definition per Qualifier is provided within the Glossary and Definitions page and
potentially a discussion of possible implications of the Qualifier in the Case Narrative if applicable.
Result
The actual analytical final result (corrected for any sample specific characteristics) reported for your sample. If there was
no measurable result returned for a specific analyte, the result in this column may state “ND” (Not Detected) or “BDL”
(Below Detectable Levels). The information in the results column should always be accompanied by either an MDL
(Method Detection Limit) or RDL (Reporting Detection Limit) that defines the lowest value that the laboratory could detect
or report for this analyte.
Uncertainty
(Radiochemistry)Confidence level of 2 sigma.
Case Narrative (Cn)
A brief discussion about the included sample results, including a discussion of any non-conformances to protocol
observed either at sample receipt by the laboratory from the field or during the analytical process. If present, there will
be a section in the Case Narrative to discuss the meaning of any data qualifiers used in the report.
Quality Control
Summary (Qc)
This section of the report includes the results of the laboratory quality control analyses required by procedure or
analytical methods to assist in evaluating the validity of the results reported for your samples. These analyses are not
being performed on your samples typically, but on laboratory generated material.
Sample Chain of
Custody (Sc)
This is the document created in the field when your samples were initially collected. This is used to verify the time and
date of collection, the person collecting the samples, and the analyses that the laboratory is requested to perform. This
chain of custody also documents all persons (excluding commercial shippers) that have had control or possession of the
samples from the time of collection until delivery to the laboratory for analysis.
Sample Results (Sr)
This section of your report will provide the results of all testing performed on your samples. These results are provided
by sample ID and are separated by the analyses performed on each sample. The header line of each analysis section for
each sample will provide the name and method number for the analysis reported.
Sample Summary (Ss)This section of the Analytical Report defines the specific analyses performed for each sample ID, including the dates and
times of preparation and/or analysis.
Qualifier Description
B The same analyte is found in the associated blank.
J The identification of the analyte is acceptable; the reported value is an estimate.
P RPD between the primary and confirmatory analysis exceeded 40%.
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 13 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 13 of 17
ONE LAB. NATIONWIDE.
Pace National is the only environmental laboratory accredited/certified to support your work nationwide from one location. One phone call, one point of contact, one laboratory. No other lab is as
accessible or prepared to handle your needs throughout the country. Our capacity and capability from our single location laboratory is comparable to the collective totals of the network
laboratories in our industry. The most significant benefit to our one location design is the design of our laboratory campus. The model is conducive to accelerated productivity, decreasing
turn-around time, and preventing cross contamination, thus protecting sample integrity. Our focus on premium quality and prompt service allows us to be YOUR LAB OF CHOICE.
* Not all certifications held by the laboratory are applicable to the results reported in the attached report.
* Accreditation is only applicable to the test methods specified on each scope of accreditation held by Pace National.
State Accreditations
Alabama 40660 Nebraska NE-OS-15-05
Alaska 17-026 Nevada TN-03-2002-34
Arizona AZ0612 New Hampshire 2975
Arkansas 88-0469 New Jersey–NELAP TN002
California 2932 New Mexico ¹n/a
Colorado TN00003 New York 11742
Connecticut PH-0197 North Carolina Env375
Florida E87487 North Carolina ¹DW21704
Georgia NELAP North Carolina ³41
Georgia ¹923 North Dakota R-140
Idaho TN00003 Ohio–VAP CL0069
Illinois 200008 Oklahoma 9915
Indiana C-TN-01 Oregon TN200002
Iowa 364 Pennsylvania 68-02979
Kansas E-10277 Rhode Island LAO00356
Kentucky ¹ ⁶90010 South Carolina 84004
Kentucky ²16 South Dakota n/a
Louisiana AI30792 Tennessee ¹ ⁴2006
Louisiana ¹LA180010 Texas T104704245-18-15
Maine TN0002 Texas ⁵LAB0152
Maryland 324 Utah TN00003
Massachusetts M-TN003 Vermont VT2006
Michigan 9958 Virginia 460132
Minnesota 047-999-395 Washington C847
Mississippi TN00003 West Virginia 233
Missouri 340 Wisconsin 9980939910
Montana CERT0086 Wyoming A2LA
Third Party Federal Accreditations
A2LA – ISO 17025 1461.01 AIHA-LAP,LLC EMLAP 100789
A2LA – ISO 17025 ⁵1461.02 DOD 1461.01
Canada 1461.01 USDA P330-15-00234
EPA–Crypto TN00003
ACCREDITATIONS & LOCATIONS
¹ Drinking Water ² Underground Storage Tanks ³ Aquatic Toxicity ⁴ Chemical/Microbiological ⁵ Mold ⁶ Wastewater n/a Accreditation not applicable
Our Locations
Pace National has sixty-four client support centers that provide sample pickup and/or the delivery of sampling supplies. If you would like assistance from one of our support offices, please contactour main office. Pace National performs all testing at our central laboratory.
1 Cp
2Tc
3Ss
4Cn
5Sr
6Qc
7Gl
8Al
9Sc
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/25/19 19:20 14 of 17
ACCOUNT:PROJECT:SDG:DATE/TIME:PAGE:
ATC Group Services - SC - Speedway 0007956 L1120024 07/26/19 11:50 14 of 17