Loading...
HomeMy WebLinkAboutMO-28796_48021_CA_CLO_20210903_UST In-Place Abandonment ReportCedar Rock ENVIRONMENTAL September 3, 2021 Ms. Suzanne Wittebort 3130 Fairfax Drive Charlotte, NC 28209 CEDAR ROCK ENVIRONMENTAL, P.C. 107 Pioneer Trail Graham, NC 27253 (336) 376-0394 RE: Underground Storage Tank (UST) Closure Assessment Report 3130 Fairfax Drive, Charlotte, North Carolina Cedar Rock Project Number 327022590 Dear Ms. Wittebort: Cedar Rock Environmental, P.C. (Cedar Rock) is pleased to submit this report describing activities and results for the in -place abandonment of the onsite UST located at 3130 Fairfax Drive in Charlotte, North Carolina. The UST abandonment was performed on September 3, 2021. Included in this report are project documents consisting of a disposal manifest and photographic documentation. This report should be kept with other documents pertaining to the residential property. Soil contamination was detected beneath the UST during abandonment activities on September 3, 2021. The release was reported to the Department of Environmental Quality (DEQ) using a UST- 61 form on September 3, 2021. Although the State no longer requires further assessment of the contamination, the State does require the filing of a Notice of Residual Petroleum (NRP) prior to conveying the property to another party. The NRP includes land use restrictions prohibiting any disturbance of site soils within a specified radius of the estimated extent of soil contamination and prohibits the use or installation of any water supply wells on the property. Cedar Rock is in the process of filing the NRP. The DEQ will issue a Conditional Notice of No Further Action (NFA) letter within the next few days. Upon receipt of proof that the local officials and adjacent property owners have been notified of the release by receiving a copy of the Conditional NFA letter, and that the NRP has been filed, the DEQ will reissue the NFA letter with no conditions to officially close out the petroleum release incident. Enclosed is an invoice for this work effort. If you have any questions, please do not hesitate to contact me at 336-376-0394. Thank you for your consideration of Cedar Rock to provide you with this service. Sincerely, W�Ct Robert A. Payne, L.G. President RAP:rp Attachments UNDERGROUND STORAGE TANK CLOSURE ASSESSMENT REPORT FOR 3130 FAIRFAX DRIVE CHARLOTTE, NORTH CAROLINA Prepared for: Ms. Suzanne Wittebort Charlotte, North Carolina Prepared by: Cedar Rock Environmental, P.C. 107 Pioneer Trail Graham, North Carolina Robert A. Payne, L.G. President September 3, 2021 CR #327022590 Section TABLE OF CONTENTS 1.0 INTRODUCTION 2.0 PROJECT FIGURE Site Map APPENDICES A Fluid Disposal Manifest B Photographic Documentation Page No. I hereby certify this 3rd day of September 2021 that this report was prepared by me or under my direct supervision. ..&#" Robert A. Payne, L.G Geologist ii 1.0 INTRODUCTION Cedar Rock Environmental, P.C. (Cedar Rock) was contacted by Ms. Suzanne Wittebort of Charlotte, North Carolina to abandon in -place an underground storage tank (UST) located at 3130 Fairfax Drive in Charlotte, North Carolina. The UST was first inspected on August 23, 2021. An inactive UST was observed to be located beneath a brick patio perpendicular to and centered approximately 7.4 feet off the western foundation wall of the house and about 9.0 feet south of the northern foundation wall of the house (see Site Map). Both the fill and vent pipe of the UST were observed to be intact. The depth to the top of the UST is approximately 31 inches below land surface (bls). The UST had an estimated length of about 74 inches with a diameter of approximately 45 inches and an estimated capacity of about 550 gallons. The UST was measured to contain approximately 284 gallons of fluid. White flagging was installed to mark both ends of the UST (see Photo 1). No other USTs on the property were discovered using a metal detector to survey the outside perimeter of the residence where USTs are usually located. No petroleum odor was observed in the crawlspace from the crawlspace entry. Due to nearby unmarked utilities, no soil borings were performed during the initial site inspection to inspect the soils beneath the tank to determine if the tank had leaked. Inspection of the soils was deferred until after underground utilities were located. 2.0 PROJECT The in -place abandonment of the UST was performed on September 3, 2021. The abandonment consisted of the hand excavation of the soils overlying the eastern end of the UST to expose the topside of the tank. A hole approximately 1.5 feet in diameter was then cut on the top of the UST to allow for removal of the tank contents, cleaning and visual inspection of the UST interior, and subsequent filling. The tank was pressure washed to remove all residual petroleum sludge. Large corrosion holes were observed in the bottom of the UST. Residual oil in the fuel lines was also removed by vacuum. The fuel lines were removed from the crawlspace. Approximately 400 gallons of fluid and sludge (including rinsate) were removed from the UST. The fluid disposal manifest for the tank contents is included in Appendix A. A soil boring was performed at the eastern end of the tank using a 1/2-inch diameter auger drill. The soils underlying the UST were observed to be discolored and to have a strong petroleum odor indicating that significant leakage from the UST has occurred. After the interior of the UST was cleaned, the tank was then entirely filled with an excavatable flowable fill cement slurry. Once filled, the exposed portion of the UST was then covered with site soils (see Appendix B - Photographic Documentation). 1 FIGURE SITE MAP 0 5 10 20 T1 = 550-Gallon UST 1 Inch = 10 Feet PROJECT: Suzanne Wittebort Property INCIDENT # Pending LOCATION: 3130 Fairfax Drive Charlotte, Mecklenburg Co. CRE PROJECT NUMBER: 327022590 CEDAR ROCK ENVIRONMENTAL, P.C. FILENAME: 3270-Figl.fc7 VERSION DATE: 9/3/21 SITE MAP FIGURE 1 APPENDIX A FLUID DISPOSAL MANIFEST NON -HAZARDOUS 1. Generator ID Number 2. Page 1 of 3. Emergency Response one *Manifest Document Number WASTE MANIFEST 5. Generator's Name and Mailing Address Generator's Site Address (if different than mailing address) Generator's Phone: 6. Transporter 1 Company Name U.S. EPA ID Number SHAMROCK ENVIRONMENTAL CORPORATION N . C . 0.0.0.0.9.4.2.1 .4.4 7. Transporter 2 Company Name U.S. EPA ID Number 8. Designated Facility Name and Site Address U.S. EPA ID Number SHAMROCK ENVIRONMENTAL CORPORATION 6106 CORPORATE PARK DR., BROWNS SUMMIT, NC 27214 (336)-375-1969 N.C.0.0.0.0.9.4.2.1.4.4 Facili 's Phone: HM 9. Waste Shipping Name and Description 10. Containers 11. Total 12. Unit Approval Codes No. Type Quantity Wt.Nol. cc 1 - w %.) 2 W 3. 4. 13. Special Handling Instructions and Additional Information t Power Unit Trailer If Job # 14. GENERATOR'S CERTIFICATION: I certify the materials described above on this manifest are not subject to federal regulations for reporting proper disposal of Hazardous Waste. Generator's/Offeror's(Printed/Typed Name Signature ` -; f Month Day Year w�'= •J• _-•. -j I— 15. International Shipments ❑ Import to U.S. ❑ Export from'.S. Port of entry/exit: CJ z Transporter Signature for exports only): Date leaving U.S.: ¢ w 16. Transporter Acknowledgment of Receipt of Materials Cc Transporter 1 Printed/Typed Name Signature Month Day Year rn z Transporter 2 Printed/Typed Name Signature Month Day Year cc 17. Discrepancy 17a. Discrepancy Indication Space ❑ Quantity El Type El Residue El Partial Rejection ❑Full Rejection Manifest Reference Number: r 17b. Alternate Facility (or Generator) U.S. EPA ID Number J U I. Facility's Phone: w 17c. Signature of Alternate Facility (or Generator) Month Day Year a z cs N W 9.1 9.2 9.3 9.4 18. Designated Facility Owner or Operator: Certification of receipt of materials covered by the manifest except as noted in Item 17a Printed/Typed Name Signature Month Day Year GENERATOR'S/SHIPPER'S INITIAL COPY APPENDIX B PHOTOGRAPHIC DOCUMENTATION ep�$ , 4 a-6, � Y Photo 1. View of the UST site prior to abandonment activities. Photo 2. View of the UST interior prior to the removal of tank contents. Photo 3. View of the UST interior after the removal of UST contents and pressure wash cleaning of the tank interior. Photo 4. View of the UST being filled with flowable fill cement slurry. Photo 5. View of the UST after filling with flowable fill cement slurry. Photo 6. View of the UST site after the completion of abandonment activities. Beverly, Trudy From: Josiah Payne <josiah.cre@gmail.com> Sent: Tuesday, September 7, 2021 7:10 AM To: Beverly, Trudy; Powers, Mark Cc: Taraban, Ron Subject: Re: FW: [External] NRP Review - Suzanne Wittebort Property CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Thank you, Trudy! Josiah On September 7, 2021 07:07:11 "Beverly, Trudy" <trudy.beverly@ncdenr.gov> wrote: Good Morning Josiah & Mark, The NRP for the Suzanne Wittebort Property has been reviewed and approved (attached). It's ready for regional supervisor review and notarization. Ron and Mark are both copied on this email since Mark will be the reviewing UST supervisor. Have a great day, Trudy Trudy Beverly, L.G. �� Hydrogeologist, Division of Waste Management -PhENorth Carolina Department of Environmental Quality UST Section, Mooresville Regional Office 704.235.2182 (Office) Trudy.B everly(a)ncdenr. gov Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Office Mailing Address: 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Branch's Underground Storage Tanks Website Address: https://deq.nc.gov/about/divisions/waste-management/ust Branch's Above Ground Storage Tanks Website Address: htWs:Hdeg.nc.gov/about/divisions/waste-management/ust/ast-program INTERACTIVE MAPS WITH DWM SITES AND PERMITTED FACILITIES: https://deq.nc.gov/about/divisions/waste-management/waste-management-rules-data/waste-mana eg ment ig s=mates File Review Procedures: hops://deq.nc. gov/about/divisions/waste-management/ust/file-review-procedures#mooresville-regional-office ONLINE ACCESS TO UST SECTION DOCUMENTS (Laserfiche): hi!ps:Hdeg.ne.gov/about/divisions/waste-management/laserfiche Document Submittal & UST File Names for Laserfiche Policies: httus://£iles.nc.gov/ncde(i/Waste%2OManaaement/DWMIUST/WhatsNew/Final-Electronic-Document-Submittal-Policv.vdf hops://files.nc. gov/ncdeg/Waste%20Management/D WM/UST/Corrective%2OAction/UST%20file%20names%20for%2OLaserfiche.docx From: Josiah Payne [mailto:josiah.cre@gmail.com] Sent: Monday, September 6, 2021 9:19 PM To: Beverly, Trudy <trudy.beverly@ncdenr.gov> Subject: [External] NRP Review CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Good evening, Trudy. I hope you had a good labor day weekend! Would you mind taking a look at the attached NRP for approval? We will be meeting with Mark around lunch time tomorrow (Tuesday) and it would be great if we could get this NRP signed then. I have also attached our inspection report that states the site is Low Risk, our abandonment report, and the UST-61 just so you have it all here. Please let me know if you have any questions. Josiah Payne (336) 684-3836 Cedar Rock ENVIRONMENTAL