Loading...
HomeMy WebLinkAboutNCD980602163_20030401_Warren County PCB Landfill_SERB C_Leachate Pumping, 1998 - 2003-OCRI r Patricia M. Backus, PE Division of Waste Management 401 Oberlin Road, Suite 150 Raleigh, NC 27605 Phone: 919-733-4996 ext. 308 Fax: 919-715-3605 Fax To: Bill Gallagher Fax: 252-257-4218 Phone: 252-257-1713 Re: Slider Pump □ Urgent 0 For Review • Comments: At°l\ NCDENR From: Pat Backus Pages: s Date: April 1, 2003 CC: □ Please Comment □ Please Reply □ Please Recycle ,.;:;, 02/19/1999 12:16 7043762439 ESHELMAN CAROLINAS PAGE 03 TECHNICAL DATA/ SPECIFICATIONS SHEET SLIDEil PUMP lnci;.ei~ .. g .. ,:::t"mp 1110C:/1mp AIR SUPPLY I I ' I \r. r. I I I . I/ ~ Specifications: Pump Type: Posftlve Air Displacement Dimensions: Materials: Fittings: Pump O.D.: 4.s· Length: 69" Weight: 30 lbs. Stainless Steel, High Density Polyethylene, Teflon Check Bells and Vlton O-Rlngs. Upper Check Ball Insert Delrln (Aceto!) Type: Stainless Steel aorb (Discharge) Stainless Steel Compression (Air Supply) Tubing: Discharge Size: 1.2· o.o. Air Supply Size: s1a· o.o. •OPTIONAl 1/4' BUBBLER UNE TUBING AVAILABLE UPON REQUEST PUMP PERFORMANCE: OPERATING PRESSURE RANGE: 0-1 oo P.s.1. MAXIMUM LIFT: 200 FEET MAXIMUM FLOW RATE: 9.5 G.P.M. PUMP STROKE VOLUME: 1.3 GALLONS PUMP FLOW RATES: AT 100 P.S.I. ON A3:1 SLOPE ACCESSORIES: P /N 9999 EXHAUST VALVE P /N 9999 WELL CAP P/N 37060 CABLE-3/16' STAINLESS STEEL 02/19/1999 12:15 704375243'3 ESHELMAN CAROLINAS ESHELMAN CAROLINAS, INC. 1127 Commercial Avenue Charlotte, North Carolina 28205 Phone: (704) 376~6408 Fax: (704) 376-2439 PAGE 02 TO: N.C. Division of Waste Management 40 I Oberlin Road Quotation Date: February 19, 1999 Reference: Raleigh, NC 27650 ATTN: Ms. Pat Backus Fax 919/733-4810 Ph 919/733-4996 Ext 308 Item Qty. Model Description No. No. Unit Price QED Slider Pump and Accessories, QED Part numbers are shown 1 1 SL6000 QED Landfill Slider Pump & Cable attachment $2,935.00 hardware, SS, Teflon, Viton, and Delrin Construction. 9.5 gpm max. flow. Pump 69" L, 4.5" Dia. 2 l 9999 CI 00 controller with 250A valve for high capacity 931.00 operation 3 1 9999 Exhaust valve Teflon coated. for 5/8" air line 123.00 4 l 9999 6" PVC slip fit well cap, w/ s.s. eyebolt 108.00 for use with 1-1/4" discharge, 5/8" air line 5 100 ft 37014 1-1/4" 0.D. nylon discharge tubing 4.75 /ft 6 100 ft 37681 5/8" Nylon air line tubing 1.81 /ft 7 100 ft 37060 3/16" SS cable l,67 /ft TOTAL 8 1 L375 Level mate, level control module 834.00 9 100 ft 35715 1/411 O.D. nylon bubbler line tubing 0,83 Total $2,935.00 931.00 123.00 108.00 475.00 181.00 167.00 $4,920.00 834.00 83.00 Estimated time for shipment of this product is l ~2 weeks after receipt of order. AU prices are in U.S. dollars, FOB Ann Arbor, :MI, and do not include, shipping, applicable taxes, and/or field service, unless specified in our proposal. Terms are net 30 days. Quotation valid for 30 days from above date. Attached Terms & Conditions are included as part of this quote. - ESHELMAN CAROLINAS, INC. ( ''"'"" ......... ......... ......... ::c ::c::c .. ~ ''"" 000 11100 -N _N.,. .,. ., .,. ---NNN NNN OF- 35o'-3:;J.o/-£: 30 1 Stn Q-= Len 'j+h of-f ,',ce--= def-+A. =- Si'n (;)- 3 0 -~-if. 6~ I St',,-, (33. 3 °) LE AC I+ ~ ./lli-li1 ?33 -o~9'Z x :3</</ Vl/ €Ll 5 -)/c;l.TH / 5ouTl-/ -Po1nPED -;2.0-2S :]~/ iv drd" to REU!Mff -/o -1 .;i_ A ,,_ POt3 :It 0001476 CUST # 0436 DATE 4/23/01 J & STOOL REPAIR 1309 HODGES STREET RALEIGH, NORTH CAROLINA 27604 • J •A-' o/f 1 µ1---"i' PH# (919)8S6-00SO FAX# (919)856-0051 NC DENR-DIV./WASTE MANAGEMERMT NC DENR-DIV./WASTE MANAGEMERMT 401 Oberlon Road ste 150 Raleigh, NC ?7605 401 Oberlon Road-STE.150 Raleigh, NC 27605 PHONE# (919)733-4996 PO .tt DIV·-0721 TERMS: Net 30 SALE: CHUCK -----------~----------------------------------------LINE PART#/ DESCRIPTION TAX QTY PRICE l DEVCt'iC-4336 y 1.00 $50,29 SWITCH PRESS SERVICE All invoices are due the 10th of the following mo~th that they are billed in. A service charge of 1.5 % will be added to all unpaid balances over 30 days past due. A 20 % restocking fee will be charged for special order returns. You must HAVE THE INVdICE for any returns. There will be a 5 % charge on credit card t"E!tu~n:. L/J ✓• _ "f;l_ ,4. J Date y',~3/o; ;:,IGN_"f:::::dL->;(Jti. C'--t-(4 ... ---· --~--:;-·-·- Parts: Discount: Tax; UPS S&H: TOTAL: Thankyou for your business .. Please Call again soon. EXTENDED $50.29 $50.29 $0.00 $3.02 $0 .. 00 ·y ,:.: .. •·n-r,·,,,. eu i•.11.i.!T;:::,,:.::,y 'Ji::.:,-:::.c ·r" :i. p -1:.: :1. c;;n f,..!(::id i:-:-:1 :i. :;::;: :.::::;:::::::;::::::::::::::;::::::: ::::::::;:::.:.:::: .................... : .. ::::::::::::::::::::::: ············:::::::: .......... . ·•·····•····· ..................................... ····::::;:;::::::::::::::: ·······•····•······· ::::::::::::::::::::::: TUTtil. .. ........ :::: ........ :::: .... ::: ..... :::: :::::::::::::::::::::::::::::::::::: ·······•· :::::::::::::.:;::::::::::: •::·:1i::;i: 'iJ..~~ 1:-. W '-n··· ....... ~~o/eJ / ·······•···· .. ···················· ............ [lJ ,, .. X:)tJ..,c.&<.uv. ......... , ... ,. ,, ... • .... y> ...................... . PClS tt-000126 l CUST tt 0436 DATE-: ::S/16/01 J & STOOL REPAIR PH# (919)856-0050 1309 HODGES STREET FAX# (919)856-0051 RALEIGH, NORTH CAROLINA 27604 NC DENR-DIV./WASTE MANAGEMERMT 401 Oberlon Road-STE.150 Raleigh, NC 27605 PHONE tt (919)733-4996 PO tt DIV-0719 NC DENR-DIV./WASTE MANAGEMERMT 401 Oberlon Road ste 150 Raleigh, NC 27605 TERMS: Net 30 $(..'!LE: JOE ----------------------------------------------LINE PART tt / DESCRIPTION 1 DEVf<---0 159 KIT GASKET 0/L BALL BEARINGS 2 DEVCAC·--437---2 V?:iLVE CHECK TAX y y QTY 1.00 1 .00 PRICE $15.97 $1.3,,19 All invoices are due the 10th of the following month Parts: that they are billed in. A service charge of 1.5 % Discount: will be added to all unpaid balances over 30 days past due. A 20 % restocking fee will be charged for Tax: special order returns. You must HAVE THE INVOICE for any returns. There will be a 5 % charge on credit UPS S&H: card ,etur-ns. ~ , • Jh v.2 ~ J ...3/t,lt:,/ SIG~~ ~ · ~ Date__ '/' TOTAL: Thankyou for your business .. Please Call again soon. EXTENDED $15.97 $13.19 $~29.16 $0.00 $1.75 $0.00 $30.,91 MapQuest! Interactive Atlas -Print 1 of 1 http://www.mapquest.com/cgi-bin/ia_ ... %16P%26%2bLY%26%2baag6mqa2%3a%2bGG ----•-" =~' www.mapquest.com .. use your browser print option to print) . He>w-g~Jo1.1rS21le~r •••••••·i11 ••8al@igftJC;l"'rHi1m?•••• dbus il't1::i..f9!n fiqgs ahq reporrs on. srnaU/groWihg blJsft1EiSSes Wh6 ate ' prime choices forago.od sa les calL checklt8 1.1t. Return to Map :,-,.:-: ........... ✓• ....... .-: .. .-:-: .. ,:,:,:,;,:,:,:,:,;.-..-..:-:--..-..-.❖-_ .................. _.._.._.._.._.._.._...❖ 03/10/2000 12:32 PM MapQuest! Interactive Atlas -Print http://www.mapquest.com/cgi-bin/ia_ ... % 16P%26%2bL Y%26%2baag6rnqa2%3a%2bGG Ml\NVfft www.mapquest.c6m ~❖'.❖:•:•:•:❖:❖Z❖'.❖'.❖'.❖'.❖'.❖:-///////h·✓-✓..,❖ U ,./ I Return to Map i 1 of 1 03/10/2000 12:35 PM Commercial Pressure Switches Class 9013, Type F and Type G-Description The Class 9013 Type F line of pressure switches are UL Listed and CSA Certified as commercial control equipment. The Class 9013 Type G line of pressure switches are UL Listed and CSA Certified as commercial/light industrial control equipment. The Type FHG -PUMPTROL® Compressor Pressure Switch is used to control electrically driven air compressors and is diaphragm actuated and has contacts that open on rising pressure. Type FHG • PUMPTROL ® Compressor Pressure Switch The Type FSG, FYG, FRG -PUMPTROL®Water Pump Pressure Switches are used to control electrically driven water pumps and have the following features: • The Type FSG is the standard water pump switch, suitable for all types of pumps: jets, submersible, reciprocating, etc. • The Type FYG is designed to meet higher horsepower and pressure requirements. • The Type FRG is reverse acting: the contacts open on falling pressure. • All are diaphragm actuated. Type FSG, FYG, FRG-PUMPTROL ® Water Pump Pressure Switch The Type G -PUMPTROL® Commercial/Light Industrial Pressure Switch is used to control electrically driven water pumps and air compressors. It has higher electrical ratings for direct control of motors in pump and compressor applications. The Type G switch is diaphragm actuated and has contacts that open on rising pressure. Type G · PUMPTROL ® Commercial/Light Industrial Pressure Switch shown with Form X-release valve IDI -9/_9_8 ______________ ©_c_1_99_8_S_q_ua_r_e_D_A_I_I R-ig-h-ts_R_e_s_er-ve_d ________________ _ 3 "'.,!2I!~D~ .!,~!?.~!!!!l~~.iDN1!,~;STS I I,-QJIANCHES.l.OCATED NATIONWIDE DUPLICATE INVOICE ·, BRANCH ADDRESS RA.LE:J.GM iooo "CARNER ·sm: n-: 20:t~t RALEIGH NC OTA Ot .. VO 27603 TELEPHONE (91.9)• Tl<t/7400 REMIT MOTION ~ND~STRIES, INC. ENT 13Yi S~£_J~A~A~?~: ~~E~SHOWN) i.l.. Ot:ttR OlJJ,tS.l~N or w.AiilTE: MfJMt. 'I . R~LilGH, NG 2760~ NC 1~7!::i907 SOLD !O CREDIT CARO RECEIPT CARO NAME: VISA I INVOICE NUMBER .I NC 17 -<371172 ' INVOICE DATE 09/1:ll'OO PAGE 1 OF l To Rf1LE.T.bH P O BOX ;'37609 RALF.::J'GH NC ~~7627 APP CODE: N6740N CNTRL I 042102 MERCHANT: 001113813317 .I I DUE UATEt 09/15/00 OCN: 1.0.f/:t.<N.i D:UH: 0 ACCOUNT NUMBER ORDER DATE DUNS NUMBER _ ii 0000<79 ... o 1 1B-<M8···9546 ·jj ---"' SPECIAL INST: MANUAL/PU/PAT DACKUS/733-4996/ 1 Q077-4.X 13~i(13., ·, NAW2000-N02-2 F/R~UNlT 1/4"NPT $33.400 THANK YOU'FOR YOUR ORDER ft~, ;-,,.: MDSE.TOTAL 33 ~ 4() IN OUT FREIGHT 24.00 .00 I' ~! ~ .,, OTHER CHARGES fl.E$IQQS!~ . ()() ,()0 EA 6. 0()00 ~3. 44 UNIT PRICE / ' t /. :!K1. 400 , /'( CASH DISCOUNT -----CASH DISCOUNT OF $ MAY BETAKEN IF PAID BY NO MERCHANDISE MAY BE RETURNED WITHOUT OUR PERMISSION. Invoices unpaid 31 days after in.voiced.ate are subject to service charge of 1-½% per month. Equivalent interest rate per annum 1s 18%. .... "THE MERCHANDISE ':81;_D IN THIS INV_,?ICE_ ~ SEEN ~~ED,~ ~ES~CT~~ ~RA~~ lN ACCORO~ ~ ~-E F~_!~ STANDARDS ACT OF 1938, AS AMENDED." Ill F I 0 ' ~ NET AMOUNT ~~3, 40 ,I \; 1 I j PAY THIS AMOUNT PO~) tt 000024:, cus·r tt 0436 DATE 3/28/00 J & STOOL REPAIR 1309 HODGES STREET RALEIGH. NORTH CAROLINA 27604 PH# (919)856-0050 FAX# (919)856-0051 NC DENR-DlV./WASTE MANAGEMERMT 401 Oberlon Road-STE.150 Raleigh. NC 27605 NC DENR-DIV./WASTE MANAGEMERMT 401 Oberlon Road ste 150 Raleigh, NC 27605 PHONE# (919)733-4996 PO .tt DV·-0677 LINE PART tt / DESCRIPTION TAX DEVSS-2707. .. . Y VALVE DRAIN 1/4 BR ........... . 2 DEV265-17..... Y r 1 LT ER F El. ·1 • .. • • • • • • • • • • • • • .. • • • TE~~MS: Net 30 t~ALE; CHUCK QTY PRICE 2.00 2 .. 00 EXTENDED $.::,. 00 $2.26 ,, t. Al 1-·i nvoi ces ... a·r·e due the 10th -of . the . fo 11 ow·i n9 ··month~ Par t;-;-··----··---$7. 26: that they are billed in. A service charge of 1.5 %¼ Discount: $0 .. 00 ~"'i 11 be added to a.l l urq::>c\id baJ ances ovEH 30 days ,, \\ past due. A 20 :\, r·es tockin1_.J fee will be char·qed for ·\. Tax: $0.44 special order· n~ tu n,s. You must HAVE THE INVOICE fori' a.11y returns. There will be a 5 'it char·ge on credit . UPS S&H: ca rd retw ns. ' L/) ...... '] A t,_ -~;; P/oo s I G N _'e.,!J.;L ~'16'-"". _ ____ _ __ _ _ __ D a t e _ ?.,c \ .:.. _ TOT AL : Thankyou for your business ... Please Cal~aya1n soon. $0.00 $ 7. ·10 PClS tt 000() :1. 'JI.J Cl.H:>T tt CUSTOMEJ~ CL/36 DATE i:l/1.B/00 J & STOOL REPAIR 1.309 HODGES STREET RALEIGH, NORTH CAROLINA 27604 PHtt (9:1.9)856-0050 FAXtt (9:1.9)856-0051. NC DEPT OF ENVI & NATURAL RES. 40:1. ClBl::RI ... IN 1:WAD • RALEIGH, NC 27605 PHONE H (9:1.9)733-4996 PO tt DIV····Ot:,·7f_:, LIME PART tt / DESCRIPTIOM TAX y TERMS:: C;:-ish SALE: SUSAN GITY 1 .. ()() Pl,ICE EXTENDED ·----------·-----------------------------------------------------------------All invoices are due the :I.0th of the following month F~a ,,·t;r:; :: that they are billed in .. A service charge of 1 .. 5 % Discount: will be added to all unpaid balances over 30 days past due. A 20 % restocking fee will be charged for s pecial order returns. You must HAVE THE IMVOICE for any returns. There will be a 5 % charge on credit c: a n:I ·t'·c•:•~tu ;;~ ;.~j~l ....... '~U ..... ~~ ····-···-·-··-·······-·D;:-1 tc~.-.1/"?. ?/Oo UPS TOTAL..: Thankyou for your business ... Please Call again soon .. ,. ~; 1. :t ... 4~:3 ~.o. oo $12.12 ~ . -,... P(lS . ft 000~.=;::.~3c:_:_, D,~TE 7 /l::l/00 ACCT tt CUffT"OMl::n INVCJicr· :r ?., S TOOi... F~EP,~IF~ 1309 HODGES STREET RALEIGH, NC 27604 PH (919)-856-0050 FAX (919)-856-0051 t>ALES PERSON C NC DEPT OF ENVIRONMENT & RES. 401 OBERLIN ROAD STE 150 RALEIGH, NC 27605 DIV. rn~ WASTE MANAGEMENT 401 OBERLIN ROAD STE 150 RALEim~, NC 27605 Phone tt (919)733-4996 PO it C;-:.'lt :: RETAIi... :I. DEVCAC···•4::l7····2 y :I.. ()() i1;:1.2 .. !;.)!:.) ~H2 .. V,~LVE CHECI< ::.~ DEV26~'i·-· l 7 y :I ... 00 1-1. 00 11,1. FILTEF~ FELT !:5~5 ()() ---------------------------------------------------------? ol -----------_Ufa _______ ---------------------------------------------------------------------- All invoices are due the 10th of the following month Parts: that they are billed in. A service charge of 1.5% Discount: will be added to all unpaid balances over 30 days UPS S&H: past due. A 20% restocking fee will be charged for Tax: special order returns. You must have invoice for Payments: any returns .. There will be a 5% charge on credit c ""d rntu;~ :;, _________________________________________________ Dai,e 'ft,;J;/C/f' B;a hnce Due:: ~;(). 8:1. ~,;:1.4,. ::~6 ,-·---·--r,--:;-· ·C 0 ~1 r -~ r--L-~o ~ ~ b UU ~ (") 13~39 HOt:aGES ::nF.:EET __,,,, PALE I 13H, tK:. :27604-1431 1 TERMINAL 1.0. ME:24UG'-.-' ,. ()MERCHANT# ~~'::'510(U)540$] 1 ~j'j '. J -· '• t·.. . -• ,. ·•··· --..__,.,, I' II I•::·•'• : ... -->H I' r 412:::0((:::54:::35741 o I , _ _i L SALE ~ r, (1(1(122:3 [ \ .. ) .JUL 1 :3, (1f1 I 1· 10 f: __,, f ! . [(? TOTAL f ij~ [o TRACE 40454 7 '"••••---..... -..,-•'• LJ"l".-.t•t-1 -•• • .• -.1.•1 ,.-, ~-~ I Please check the merchandise you are purchasing to insure all items are received as Lowe's cannot be responsible for shortages after you leave Lowe's warehouse. Your signature acknowledges Lowe's delivery and your receipt the date set forth below of:all items of merchandise, except those items noted as being for later delivery (e.g., LO = Lowe's delivery; PL= Pick up later; SOS= Special Order Sale; or WH = Warehouse or back of store pickup). Your not signing acknowledgment of receipt, however, does not mean that such merchandise !was not delivered. All claims and return of merchandise MUST be accompanied by this Invoice and made within 30 days of delivery for credit or rpfund. This document may also evidence a return of merchandise described below if "Return" is printed with referenc~ to an item. In such instance you ~ will be given credit or cash as described and your signature represents you acknowledgement of the accuracy of the terms and conditions of the return. SEE REVERSE SIDE FOR (1) PAYMENT TERMS AND CONDITIONS FOR CERTAIN PURCHASES ANQ (2) WARRANTY INFORMATION AND AGREEMENTS. DO NOT SIGN THIS INVOICE UNTIL COMPLETE AND YOU HAVE RECEIVED AND ACCEPTED THE MERCHANDISE ( CURRENTLY BEING DELIVERED TO YOU AND YOU HAVE READ THE REVERSE SIDE. YOUR SIGNATURE CONSTITUTES YOUR AGREEMENT WITH APPLICABLE PROVISIONS ON THE REVERSE. YOU ARE ENTITLED TO A COPY OF THE INVOICE. if i Form# 89504 14/99\ RECEIVED BY (_ I TRANSACTION CUSTOMEfl DATE PAGE INVOICE NUMBER (_ If LOADED Loaded INITIAL ./ QTY UNIT ITEM# DESCRIPTION UNIT PRICE EXT. PRICE t ".":"-•'7> .. : : .... ,~·, -· ·. ···i'•i TI • (_ '1\ I : _;' . ) ,· ... --J ' -- k ;-~{ (''//}~(jtff P -) I I PURCHASE ORDER NO. REF. NO. BUYER CODE SALES PERSON I TOTAL I I 'r:=-, •• ,, cr:::rH..1r.ei i:.~st;JJT8 ~fo!l@IJ'ltiEG8oi'Pr f1!i.,~•~ -ruc ... F·-:-•:· !--------------------------------------------------·----------------------------------------1 . I I I ! EDMAC COMPRESSOR COMPANY ~dmac Compressor Company 701D Salem Avenue W1ns:on-Salern, NC 27101 SHIP TO : 120597 Ne Dept. Oi Envir-Wast.2 Mr;mt. 401 Oberlin Rd Suite 150 BILL .,.~ l.. .) • Pick Ticket 00 102264-010-001 ~AGE 1 DATE 03/16/2000 ~Jc: Dept. Of Envir-Waste '.'fgmt. ➔01 Oberlin Rd Suite 150 ~:, ~ 1 -...: .... ~ ,-,..... .... -,Cflt=: -·-----:;i-1 ., ..... :----------------1----------1----------1-----1~--' ----------'---1-----------1--------------1 ! PO# / Ref.# !Order Dat.e j Req . DatelSlsp. i ~ems : '.vHI ?reight 3hi~· """ !----------------1----------1----------1 -----1---------------!---!-----------1--------------, iDIV-06-25 j03/16/2000j03/16/2000ll2 jNet .30 Days !•310IFrepaid ,U?S G:t cund , j----------------'----------i---1------:---;-!--------------i---:---!-------:---1--i-------i ! I:.em Descr::.·::.t:.on Ordered i Shipped i 3ackoraer .it ! ·,i1.;,;...;:1r. l Ui1 i Loe : 1-------------------------------·----------'----------· ---i-------------·------- :0:::rder initiated .3.·c, 1·:r,se IJG,J . :-:i:-~:-:3::-::4S: i~ilkerson Repair Kit i I I I I I I 04C3 I I I I I I I ! i l-------------------------------1----------1----------1----------1---1-----------i--i-------i All returns are subject to restocking charges. Total I .000 !LB Cutoff Date 03/16/2001 Weight 1-----------1 ' ICR.OPURGE® £..Z Stacker™ SAMPLE PRO ® rom The Leader in Low Flow Sampling 'YQED ETDUGI PUMPS™ ,..,,,,,. TQl!I) t;,.,;,.,,,..,,..,., ,\)~1 ..... ,. '""'· ~@fb@llJ® ~ QuickFilter® ~ .. (ta !Hlw@ll1.fl_u11cH R ~ ,,. WELL WIZARD ® E"ZTray™ Innovative products from the world's largest manufacturer of pneumatic pumps for ground water and landfills FEATURED PRODUCTS Ferret™ Separator Pumps Product-only floating hydrocarbon recovery with no water -guaranteed! • Up to 300 GPD (1,137 LPD) of gasoline, other light hydrocarbons to #3 fuel oil. • Makes any well, tank, sump or pit into an oil/water separator! • Outperforms belts, ropes, discs, skimmers, and hydrophobic screens. Patent Pending YellowJacket™ Oil/Water Interface Meter Ergonomic flat-reel design engineered for efficient "point & shoot" operation. • One-hand trigger clutch -smooth probe descent at the speed you choose. • Flat reel with built-in tape wiper -precision winding, no tangles, no mess. • Advanced probe design -rugged 3/4" O.D., adjustable sensitivity. • Rugged, all aluminum construction and 3rd-generation electronics. QuickFilter® Ground Water Sample Filters QED is your best source for in-line disposable field filters. • Standard & high capacity models in 0.45, 1.0, and 5.0 micron pore sizes. • Exclusive Clean Rinse5Mprocess protects sample purity -at no extra cost. • In stock for immediate shipping -with the industry's best price. • Improved! High-throughput polysulfone membrane increases flow capacity. MicroPurge® Low-Flow Sampling Equipment The only complete low-flow ground water sampling system available. • Model 400 Digital Controller with 500-well data recall. • Model FC5000 Flow Cell/ Analyzer displays and records 7 purge water parameters. • Model 6400 Water Level Meter logs well level continuously. • Proven Well Wizard bladder pumps -used in over 40,000 wells worldwide. U.S. Patent No. 4,585,060 and 4,489,799 Solo® II Automatic Leachate & Cleanup Pumps Reliable, economical landfill and ground water cleanup pumping. • Flow rates up to 7,200 GPD (27,250 LPD) 4" (100 mm) wells; depth to 200' (61 m). • Proven workhorse performer in thousands of wells worldwide since 1990. • Stainless Q-Tal construction, top or bottom inlets, standard or short models. U.S. Patent No. 5,141,404 ,.. 'QED Environmental Systems, Inc. P.O. Box 3726, Ann Arbor, Michigan 48106 800-624-2026 Fax: 734-995-1170 E-Mail: info@qedenv.com www.qedenv.com EQUIPMENT RENTAL AVAILABLE GROUND WATER SAMPLING Well Wizard® Bladder Pumps The leading dedicated sampling pumps since 1982 -over 40,000 wells worldwide. • Depths to 1,000" (305 m), well I.D. from 1.25" (32 mm) up. • Low & standard flow models. •Teflon®, NSF-certified PVC, and type 316 stainless steel models. Teflon is a registered DuPont trademark HydroPunch® Direct Push Samplers Direct push sampling without wells -cuts site assessment costs 50-75%. • The original direct push ground water & hydrocarbon sampler. • Usable with drill rigs, cone penetrometers, and full size probes (2.0" /50 mm O.D.). U.S. Patent No. 5,146,998 Sample Pro® Portable Sampling Equipment Full line of professional portable sampling equipment & supplies. • Rugged portable pneumatic sampling pumps and well development pumps. • Bailers, hose reels, water level meters, tubing, connectors, and more. LANDFILL AND CLEANUP PUMPS HammerHead™ High-Performance Automatic Pumps Leachate/condensate, skimming, total fluids, or drawdown pumping. • Up to 21 ,600 GPD (81 ,750 LPD), 4" (100 mm) wells; depth to 300' (91 m). • Up to 3,600 GPD (13 ,625 LPD), 2" (50 mm) wells; depth to 200' (61 m). • Rugged cast-stainless or SS/brass construction with Teflon® and Q-Tal. U.S. Patent No. 5,358,037 Tough Pumps TM Pneumatic Specialty Pumps • Eliminator pumps -no VOC emissions, surface controlled bladder pump for strict air reg compliance or skimming viscous hydrocarbons. • Seeker® pumps -floating hydrocarbon recovery up to 60 GPD (227 LPD) via patented triple float inlet with 24" (61 cm) working range. • Slider™ pumps -slant/horizontal pumping for special projects: sloped leachate risers, trenchless plume interception, inaccessible sites. • Pulse Pump® system -simple, rugged pneumatic pumps in Teflon®, stainless steel, PVC, and brass for sinking layer and hazardous duty sites. U.S. Patent No. 5,141,404 GROUND WATER TREATMENT TQID Environmental Systems, Inc. E-Z Tray TM High Performance Air Strippers Removable-tray air strippers for high performance, low O&M costs. • Efficient VOC removal up to 99.999% at 1-25 to 1-200 GPM ( 4-95 to 4-757 LPM). • Fully-equipped, wet-tested stainless or epoxy-coated steel models. • Space-saving removable tray design cuts cleaning labor by 80%. U.S. Patent No. 5,358,037 E-Z Stacker ™ Economy Air Strippers Compact, stackable air strippers for economical treatment system integration. • Efficient VOC removal up to 99 .999% at 1-25 to 1-40 GPM ( 4-95 to 4-151 LPM). • Engineered HDPE units provide positive-seal, leak-free performance. • Easy disassembly cuts cleaning and maintenance costs. Treatment Process Elements & Components • Control Panels - U/L listed, NEMA 3 or 4 standard enclosures, 1 light per alarm. • Oil/Water Separators -small-footprint, integral-tank units to 77 GPM (291 LPM). • Liquid and Vapor Phase Carbon - 175-2 ,500 lbs. (80-1 , 136 kg) fill. • Transfer Tanks -(60-230 gal/235-870 1) & Bag Filters -(0-100 GPM/0-380 LPM). P/N 2180 Rev. #2 12-6-99 · Q E D Environmental PAGE NO: 1 Systems, Inc. INVOICE NO: 083451 P.O. BOX 3726 ANN ARBOR, MICHIGAN 48106 INVOICE DATE: 02/23/2000 TEL: (734) 995-2547 FAX: (734) 995-2125 r [ CUSTOMER NO: NOR743 CUSTOMER PH: BILL TO: NORTH CAROLINA DWM 401 OBERLIN RD SUITE 150 RALEIGH NC 27605 TERMS: CASH #1: DISC: CASH #2: DISC: NET DUE DATE: 032400 YOUR CUSTOMER REP IS: INT I N V O I C E ) YOUR ORDER NO: WARRANTY OUR ORDER NO: R12710-0000 SHIP TO: NORTH CAROLINA DWM 401 OBERLIN RD SUITE 150 RALEIGH NC 27605 SHIPPED: 02/23/2000 SHIP VIA: FED-X STD 2/22/00 F.O.B.: SHIPPING POINT SHIPMENT NO: 054537 REF: PRO NO: QTY ORDERED QTY SHIPPED QTY ITEM B.O. NUMBER UNIT PRICE EXTD PRICE *******************ordered byPat Backus***************** 1 1 0 SR-C100 CONTROLLER-REPAIR PARTS CONSISTING OF: ORDER CODE DESCRIPTION [HY 36850 34146 ----------------------- GAGE, 1 1/2" 0-160 ELBOW, 1/4"T X 1/4"MPT 1 1 0 SR -C100-L CONTROLLER-REPAIR LABOR 1 1 0.00 0.00 *******WE NOW ACCEPT VISA/MASTERCARD/AMERICAN EXPRESS******* *ALL RETURNS ARE SUBJECT TO APPROVAL/RESTOCKING FEE* A SERVICE CHARGE OF 1 1/2¾ PER MONTH WILL BE APPLIED TO ALL PAST DUE INVOICES. SALES TOTAL: SALES TAX: FREIGHT: LESS: OJHER CHARGES: INVOICE TOTAL: 0.00 0.00 0.00 0.00 0 .00 0.00 -------------------------------- Terms and Cond11ions of Sale l. Acceptance of Ords:r Orders are subJect to acceptance in writmg by Seller at its home office. 2 Transportation Tt:rm~ All shipments are F.O.R. poi111 of origin. Seller 1s not responsible for damage to or loss of goods 111 rrans1t. 3 I:'..ayment Terms Unless otherwise stated. net payme111 is due thirty (30) days after shipment. Overdue accounts arc subject to a service charge of 1 1/2 % per month. Buyer shall pay any collecuon fees and reasonable attorney's fees incurred by Seller in collecting payment of the purchase price and any other amoums for which Buyer is liable hereunder. 4. illM Open account terms will be extended to firms with satisfac1ory commercial credit rating. An open account agreement must be properly filled oul and signed by an authori,.ed pany. In the absence of adequate credit information, the order may be shipped C.O.D. or Prepaid to avoid delay 5. L1M.:Ll.lli.!...Fees Price~ shown do not reflect any Federal , State. or Local taxes which now exist or hereafter may be imposed. Orders are accepted with the understanding that such taxes ~ver's re,ponsibil11y and will be added as the law requires. The failure of Seller to charge Buyer tax where applicable does not many way relieve the Buyer of the tax obligation. 6. Deliver_x Specified tlelivery dates are approximate and subject to change . Seller is not responsible for delays due to strikes, fires. government action. or any other cause~ beyond Seller's rnntrol Seller 1s not l1ahle for loss of use or profits or to interruptions of' business activity for any 1m:idental or consequential damages resulting from delayed delivery or from any other cau~e. 7. l~ct-Warranty and Ren'lk.d,Y. The only warranties applicable to the items being purchased are those set forth on the warranty documents. All implied warranties, including without limitation implied warranties of merchantability and fitness for a particular purpose, are hereby disclaimed. 8 . ,C,am:.cllilliJm After Seller accepts, no order may be ca"celed without Seller's written consent. Cancellation. if approved. is contingent upon Buyer's payment to Seller as liquidated damages ot a charge computed to cover all costs incurred by Seller on terms acceptable lO Seller. 9. A,si~nment Neither party may assign this agreement without written con~ent or the other party. 10. Governini: Law All quotations an<l sales hereunder shall be governed and construed in accordance with the internal laws of the State of Michigan. Exclusive jurisdiction and venue over any di~pute between Seller and Buyer shall exist in the federal and state courts located in Washtenaw County. Michigan and Buyer consents to the jurisdic1ion of such courts. l I. Contra1y Terms and CQml.i.liQlli Buyer's order is accepted only or, the terms and conditions stated herein. and Seller·s acceptance of Buyer's order is expressly made conditional upon Buyer's assent to such terms and conditi(!flS. Notwithstanding any contrary terms in Buyer's purchase order. the acceptance or QED Environmental Systems, Inc. products shall conclusively estat..lish the assent by Buyer to these terms and conditions. No change in or waiveror modification of any or the terms and conditions. nor any addition .or delellon, will be accepted by or binding upon Seller unless in wrning and signed by Seller's authorized representative at Seller's home office. The terms and conditions herein are intended by the parties as the complete. exclusive and final expression of their agreement. and any understandings, representations, or agreements outside the provisions of this instrument du not constitute any part of or in no way affect this contract. Buyer's acceptance of goods shall conclusively establish Buyer's assent to these terms and conditions. 12. Ii11e Notwithstanding any other provisions hereof. title to any equipment intended to be sold hereunder. including all accessories. other equipment and parts hereinafter attached or substituted shall nm pass to Buyer. and Seller shall have a security interest, with all rights and privileges therein. ulllil all unpaid sums are fully paid. Q E D Environmental Systems, Inc. P.O. BOX 3726 ANN ARBOR, MICHIGAN 48106 TEL: (734) 995-2547 FAX: (734) 995-2125 LN# ITEM/CATALOG i TEM · ·1: -;•~ ! c:r:!:: t·•;-·• I . t.-"••:i j ;-..'. ! i "!" = f~ r ·:-1 -~if,{ ,_· 1: .. ! r, :-,. ~ i I r· ! .r . t : :. UM L I S T ORDER QUANTITY . II ; I·' " · I i. _ · .. , 4, :,71;--: ; J· 1::1~ : QUANTITY DUE SHIPPED QUANTITY l . BACKORDER ORtlER coMl'tEtE . ' tJl- ;··, I t • ·• lp ! l BACK.ORDER QUhNTITY Te rm urui ~ tlJ,&C.llliUJ.1.:.~.Q.f-j)J_d_i:_r Ordt'rs are sub1ect to acceptance in writing by Seller at its home office. 2 lI.fil1~n.u1lfili®_:r.~m~ All shipments are F.O.B. point of' origin. Seller 1s not responsible f'N damage to 01 loss of goods in transit. 3 r,mnw.1-I~rn.lli Unlt:ss otherwise stated. net payment is due thirty (30) days after shipmen!. Overdue accounts arc subject to a service charge of 1 1/2 % per month. Buyer shall pay any rnllection kc~ and reasonable attorney's fees incuncd by Seller in collecting payment of the purchase price and any othet amounts for which Buyer is liable hertunder. 4. C.rs:.CJ.!.! Open account term~ will be extended to fi rm~ with•satisfact0ry commercial credit rating:--An open account agreement must be properly filled 1,ut and ~1g11ed by an authorizeu patty. Jn the absence of adequate cred it information, the order may be shipped C.O.D. or Prepaid to avoid delav s. J al\ti..a..fill ... Em; Prices shown do lllll rd lect any Federal. State. ur Local taxes which now exist or hereafter may be imposed. Orders are accepted with the underslanding that such taxes ru:~ Buxcr:~l2Qlllili.i.!ity and will be added as the law requires. The failure of Seller to charge Buyer 1ax where applicable does not in any way relieve the Buyer of the tax obligation. 6. l2rlLY1'.D'. Specified delivery dates are approximate aml subject to change . Seller is not responsible for delays due to strikes. fires. government action, or ;my other cause~ lieyl)nd Sellcr·s control . Seller i:: nm liable for loss of use or prnfit, l'f to imerruplions of business activity for any 111cidental or consequenttal damage~ ,-<'~ultin!! from delayed delive1y or from any other cause. 7. Li.n.J.ili:.d_}VJUrant)'..allil.Ji.c.!lli;.Qy 'Jhe only warra11tie, applicable to the items being purchased are those set forth on the warranty documents. All implied warranties, including without limitation impli,:.d warra11tte, nf mcrcha11tahility and fitnes~ for a particular purpose, are hereby disclaimed. s . Q!Jlrul.~IJ.lQJJ After Seller accepts, no order may be canceled without Seller's wri1ten cm1sent. Cancellation, if approved, is contingent upon Buyer's paymem to Seller a~ liquidated damages of a charge computed to cover all cos1s incurred by Seller on terms acceptable to Seller. 9. &.,'c.'i.!g.!.\.1.!ID)l Neither party may assign this agreement withou1 written con~ent of the other party. 10 Q.Q.~rn~ .LJ!,Y All 4uotations and sales herrunder shall be gl>vern.::d and construed in accordance with the inrernal laws of the State of Michigan. Exclusive JUI isdictilln aml venue over any dispute between Seller and Buyer shall exist in the federal and state courts located in Washtenaw Cou my, M i..:higau and Buyer consents to the jurisd1c1ion of such courts. J I . .CQ!lU:iH.Y:[t;1l!!L3J!d.J.\1.11.dithl!l~ Buyer·s order is acceptrd lllll)' or, the term; and condit ions stated ht::rein. and Seller's acceplance of Buyer's order is expressly made .:onditional upon Bu:vc1 ·~ assent 10 such 1erm, and conditions. Notwithstand111g any contrary terms i11 Buyer's purchase order, the acceptance of QED Environmemal Systems, Inc. products shall rnnclusively es1ablish the assent by Buyer to these terms and conditions. No change in 01 waivt::1 or modification of any or the term~ and rnuditions. nor any addition or deletion, will he accepted by or binding upon Seller unless in writing and signed by Seller'\ authorized representative al Sella's home office. The terms and conditions herein arc intended by the parties as the co·mplete~ exi:Jusi~e· and final j:xpression of their agreeml:nl. and any understandings, representations, or agreements outside the prov,,,ions of thi~ instrument do m1t constitute any part of or in no wa) affect this contract. Buyer's acceptance of goods shall conclusively establish Buyer's assent to these tt:rrns and conditions. 12. Iilk Notwithstanding any other provisions hereof. title hJ any equipment intended to be sold hereunder. including all accessories. other equipment and parts h~1-1&,ttached '.'r ~1.1h,t1tuted ~hall tlllt pass to Buyer, and Seller shall have a security imen:st. with all rights and privileges therem. unci'I ~'tf-it~Jl\1 n,r~~~v paid. . Q E D Environmental Systems, Inc. P.O. BOX 3726 ANN ARBOR, MICHIGAN 48106 TEL: (734) 995-2547 FAX: (734) 995-2125 SOLD TO:NOR743 NORTH CAROLINA DWM 401 OBERLIN RD SUITE 150 RALEIGH NC 27605 P A C K I N G ORDER NO: SHIPMENT NO: PAGE: R12710 1 dL- DATE: CUST PO NUMBER: 02/2E~/21Zl00 WARRANTY L I S T SHIP T0:000000 NORTH CAROLINA DWM 401 OBERLIN RD SUITE 150 RALEIGH NC 27605 SHIP VIA:FED-X STD 2/22/00 MISC #1: MISC #2: FOB: SHIPPING POINT TERMS: .0% -0 DAYS; .0% -0 DAYS ; NET: 30 DAYS TOTAL: PIECES: WEIGHT: LBS VOLUME: CU FT ATTN: PAT BACKUS 919-733--4-996 ORDER QUANTITY SHIPPED BACKORDER LN# ITEM/CATALOG ITEM UM QUANTITY DUE QUANTITY QUANTITY 001. SR-C100 EA 1 1 CONTROLLER-REPAIR PARTS 002 SR-C100-L EA 1 1 CONTROLLER-REPAIR LABOR Terms and Conditions uf Sale 1. Acceptance of Order Orders are subJect to acceptance in writing by Seiter at its home office. 2 Tramportation Term;, Al! shipments are F.O.B. point of origin. Seller is not responsible for damage tO or loss of goods m transit. 3 Paym1:m Terms Unle~s otherwise stateu. net payment is clue thirty (30) Jays after shipment. Overdue accounts are subject to a service charge of I 1/2% per month. Buyer shall pay any collection fees and reasonable attorney's fees incurred by Seller in collecting payment of the purchase price and any other amounts for which Buyer is liable hereunder. 4. .cruiJ.1 5. Open account terms will be extended to firms with satisfactory commercial creuit rating. An open account agreement must be properly filled out and signed by an authorized party. In the absence of adequa1e credit information, the order may be shipped C.O.D. or Prepaid to avoid uelay Taxe~ and Fees Prices shown do not reflect any Federal, State. or Local taxes which now exist or hereafter may be imposed. Orders are accepted with the understanding that such taxes are Buyer's responsibility and will be added as the law requires. The failure of Seller to charge Buyer tax when: applicable does not in any way relieve the Buyer of the tax obligation. 6. lliliver.v. ::- Specified uelivery dates are approximate and subject to change. Seller is not responsible for delays due to strikes. fires, government action. or any other causes beyond Seller's contrnl. Seller 1s not liable for loss of use or profits or to interruptions of busint::ss activity for any mcidental or consequential damages resulting from delayed delivery or from any other cause. 7. .Lirr!fild Warranty and Remedy The only warranties applicable to the items being purchased are those set forth on the warranty documents. All implied warranties, including without limitation implieu warranties of merchantability and fitness for a particular purpose, arc hereby disclaimed. 8. Cancellation 9. 10. 11. 12. After Seller accepts, no order may be canceled without Seller's written consent. Cancella1ion. if approved. is contingent upon Buyer's payment to Seller as liquidated damages of a charge computed to cover all costs incum:d by Seller on terms acceptable to Seller. ~lIOOll Neither party may assign this agreement without written conselll of the other party. Governin!i Law All quotations and sales hereunder shall be governed and construed in accordance with the internal laws of the State of Michigan. Exclusive jurisdiction and venue over any dispute between Seller and Buyer shall exist in the ·federal and state courts located in Washtenaw County. Michigan and Buyer consems to the jurisdictiun of such courts. Contrary Terms and ConditiOlli Buyer's order is accepted only (lfl the terms and conditions stated herein. anu Seller's acceptance of Buyer's order is expressly made conditional upon Buyer's assent to such terms and conditions. Notwithstanding any contrary terms in Buyer's purchase order, the acceptance of QED Environmental Systems, Inc. products shall conclusively establish the assent by Buyer to these terms and conditions. No change in or waiver or mollification of any or the terms and conditions, nor any addition or deletion, will be accepteu by or binding upon Seller unless in writing and signed by Seller's authorized representative at Seller's home office. The terms and conditions herein are intended by the parties as the complete. exclusive and final expression of their agreement. and any understandings, representations, or agreements outside 1he provisions 0~¥14> insrru. P1ent do not constitute any part of or in no way affect this cotllract. Buyer's acceptance of goods shall conclusively establish Buy<!~~ep~ 1_1 tl;i.c~c terms and conditions. I' ~ . . •. : .. / Notwithstanding any other provisions hereof. title to any equipment intendeu 10 be sold hereunder. including all accessories. other equipment anu parts hereinafter attached or substlluted shall 1101 pass to Buyer, and Seller shall have a security imerest, with all rights and privileges therein, until all unpaid sums are fully paid. AUG-19-99 10:14 EDMAC ~/ v-0 {t 0f .Rtlcu(l,pa, ■ Numbflr ar Paaet to follow. 10: & r: Ba:w 0 :z r.o: Fa: Message: M ~4, .... DY-FOO Charictte. NC ~ Columbia, SC GfNnvllle, SC 503-695-0440 884-286-251g WILKERSON. -Rietschle R11: COJUJORATE OFFICf P.O. Bo.I 227 WIMlm14kttm. NC 271ft Ptt: J3f-72S-23H Fu: 331-725-2111 P:01 \NIAii V 1 RcoTe ii&iiaM ~ HlclmrY, NC "9: 111-212.,,_ WNmilgtan, NC 104-3:ZZ.Q21 -= .1 .. 212-S D10-3Q2-1-'33 i . EDMAC . ;.Coalesci~g Filter 'M26 .. Aulallflin M26·02·000 Features • Manual drain . . • 0.01 micron rated filter element. • Quick-disconnect bowl guard with Integral plastic bowl and safety latch. • Differential pressure indicat~r. TEL:9192123792 SpectflcatlOM Flow Capacity• 1/4 55.0 scfm (25,9 dm•ts) 3i8 65.5 scfm (30,9 d,nl/s) 1/2 79.5 sctm_i~I~5 ~'•> Maximum Operating Poly. Bowl 125"F (52°C) Temperature Metal Bow! 11s•F (79°C) Maximum Supply Poiy. Bowl 150 ~g po bar) Pressure Metal Sowl 200 psig ( i 4 bar} Standard Filtration Micron {Bl c.s, {Cl om {O} 0.003 ppm \i.r1•• Uoeful Retention oz. (cm3) 1.7 (51,5) Port Size NPT/8SPP-G 1/4, 318, 1/2 Weight lb. (kg) .. -,,. "' ~-• \1, !J "Inlet pressure 150 psig (10 bar). Pressure drop 3 psid (0,2bar}. **Filtration temperature of 70°F (21°C) @ 100 psig (7 bar} with typical compressor lubricating oil and protected by Type C filter. "M" Slf1et Coalelclng Fitters, wltfl Type "B" 0.5 micron eiemtnil: Aii Wilkerson Type 'M' Oil Removal (Coal&scingj FiltetS with Typ;, ·s• C.5 micron elements exCNd ISO Class 2 for maximum particle &ize and ooncentration of solid oonlaminants, and uc.d Class 3 on maximum oii contant (ppm,'.it). --c--- "M" Serie• ColltKlng Flltec'a, with Ty.,. "C'' 0,01 llllclon elementa: All Wilkerson Type "M" Oil Removal (Coalescing) Filters with Type "C" 0.01 micron elements 11011d ISO Cius 1 for maximum particle aize and conoentrallon of solid contaminants, and uc.ecl Class 1 on maximum oil content (ppmiwt). 0 0 0 DlmlnlkN Automatic Mtchanlcal Drain M28-XX•RIO 176 lnot,M """ E-"M" SerlN Absorption Flltert, with Type "D" actlvlted carbon eiMlentl: ,._. ----, ,--J~~-+--J All Wilkerson Type "M" Abtiorp!iOn Fitters with lype "O" acttvated c ... wn eiemants exceed ISO Class 1 on mllXimum oil content (ppm'wti. Matlrl1l1 of Conatructlon LJ I / Body Bow!s Element Retainer Filter Elements Seals A a 8.2 3.3 208 84 8.2 208 8.2 3.3 84 3.3 ,.•,·~~ • ....:,;,i;i • .,,_;."-............... ~--~. •'·,•" C 3.0 76 3.0 76 3.0 76 Plastic Bowl Metal Bowl Type B, C TypeD ...... ~ ,_,,. '""-··· Zinc Polyca.'bor.ate ~ .. ""'" _,..,. Soroamcai. C!oth Acti\/!!!€K1 C;1rtx>n Fluor0C4.~,j • .,,at Wilkeraon~ AUG-19-99 10:14 EDMAC lacement Bowl Kits Bowl, Manual Drain .............................................. GRP-95-929 Bowl/Guard Manual Dl'aln .................................... GRP-95·935 Bowl, Manual Drain ................................................ GRP-95·930 Bowt/Guard Automatic Drain ................................ GRP-95-948 Bowt, Automatic Drain ............................................ GRP-95-960 ' 1'ype 8 0.5 Micron ............................................................ MSP-95-989 i.r Type C 0.01 Micron .......................................................... MTP-95-549 v'1ype Don Vapor AemOVing ............................................. MXP-95·540 ·~ .. , ,, Accessories ::; .. Wal Mounting Bracket, L•Type ......................................... GPA-95-946 ~~: .. Automatic Mechanical Drain ............................................. GRP-95-973 ~·.Manual Flex-Tip ................................................................ FRP-95-610 :"1. Differential Pressure lndicator ........................................... DP2·01-000 Cap, Oiff8fentlal Pressure Indicator (for pressures ;,,_;~.r.. 0\411' 150 pslg) ............................... , ................................ GRP-95-020 ;·:t. Drain, Manual Override for Auto Float Drains with ;_. 1/8 NPT Port .................................................................. GRP-96-000 ..... .... ~ ... J. ,"', ·,~•. -~· ,~,~· J l lni.tl'reuure pelg ,s 35 eo 90 bat ,.o 2.4 4.1 8.2 3 I .0,2 I 2 o,, 0 0 0 10 20 30 40 50 0 5 10 15 20 AIR l'LOW RAT! Ordaringlnformatfon •. JfJji_ .. *1.)':_..,r-•--,-............. .. ...... ft11),i!'~~<f:)l• ,, ;:)~tfllff,e Minuit Drain ~illG:'1 ~~cal -. . . <t;• :.: . 1/4 3/8 1/2 1/4 3/B 1/2 100 7.0 2~ M28-03-000 120 8.2 60 ~ 150 10.3 70 scfm dm3l8 M26·02·000 t.126-03-000 t.126-04-000 M26-02-FOO M26·03-FOO M26·04·FOO la .0 Q,. 0 0.2 a: 0 UI = ;, ~ a: o., CL 0 jg ~ 0.2 I§ t ~ 0.1 a: a. 0 TEL:9192123792 E Q. Inlet Prt1NUre pelg .,., 3 2 0 s j Inlet Prauura Q. pel9 bet J 2 0 0 0 M26·02•MOO M26-03-MOO M26-04-MOO 111 ,.o 2Q 10 1& 35 !!O 1.0 2.4 4.i 10 15 A:R r .. cw RAT! ,& eo 1IO 100 2.4 .. , e.:z 7.0 40 eo 20 30 AfRl'LOWfllATI M26-02·SOO M26-03-SOO M26-04-SOO Optlona -To oroer an option supplied with the unit model, add the appropriate coded suffix letu,r In position 6, 1; 8 of the model number. For lldditlonal Information on accessories and repair kits refer to pages 326 through 334. Wllk8!80l'I c«Doratlon M2t-«i-OOO 90 , oo 120.-.n o.I a.2 1,0 &.2 IV:\J / aclm 20 Mff-04.«)0 120 1!1G u 10.3 llC ICfm 40 dnl3/t M26-02•XOO M26-03-XOO M28-04-XOO · P :03 I I • 'II J I = -~ '11 .J:·,·" . • . t i ·!-ii •• - 'ti 'a . { -"■ ·,:. •• , !"'Al.JI:. NU : l · Q ED Environmental Systems, Inc. P.O. BOX 3726 ANN ARBOR, MICHIGAN 48106 . .-.. -.· ---· ..:_. ·""'i .·, . ,->~~\ INVOICE NO: INVOICE DATE: 07940 1 07/19/1999 TEL: (734) 995-2547 FAX: (734) 995-2125 «<' -. ·' \ N v qj I C E -..,-.. ~ .. , -. ~~ .. ..~ . ~:ii ·-:r ~•;~··!'er' ---~: "'-' , :usTOMER NO: NOE74 3 :.:.us TOMER FE : 3ILL TO: ~--J :., Ci_ t:, S ;.,. (:~'.-- NOR TH CAR OLINA DWM -----~ 401 OBERLI N RD SUITE 150 RALEIGH NC 2760 5 rERM S : CA SH #1: DI SC: CASH #2 : DISC: NET DUE DATE: 0 8 1899 (OUR CUS TOME R REP I S : INT ~U~ _OROER -NO: PAT BAC'K?Js'~ OUR ORDER NO: 99R-27405-0000 SHIP TO: NORTH CAROLINA DWM 401 OBERLIN RD SUITE 150 RALEIGH NC 27505 SHIPPED: 07/19/1999 SHIP VIA: FED X ECO NO 7 -15 F . O. 8 . : SHIPPING POINT SHIPMENT NO: 050552 REF: PRO NO: QT Y ORDERE D QTY QTY ITEM UNIT PRI CE EXTD PRI CE SH IPPED B. 0 . NUMBER 0 37257 12.75 Fj i.T ER ELEMENT FRE IGilT •"'"'"'• .... WE NOW ACCE PT VISA I MAS )ER CAFW / AMER I CAN EX PRESS ••••••• •ALL RE TURNS ARE SU BJECT TO APPROVAL/RESTOCKING FEE• A S ER VI CE CHA RGE OF 1 1 1 2 % PER MONTH WILL BE AP P LIED TO ALL PAST DUE I NVOICES. SALES TOTAL: SALES TAX: FREI GHT: LES~;: CITHEE CHA RGES : IN VD I CC TOTA L: G.50 2s . =,ei 0 .0 0 £,.E,0 e,. 00 e,. e10 32 . 10 EDMAC CG1PRE8Sai COMPANY ORDER#: 60958 06/22/99 1 5 PO BOX 10489 701D SALEM AVENUE WINSTON-SALEM, NC 27101 SOLD TO: 052366 NC DEPT. OF ENVIRONMENT P.O. Box 27687 Raleigh NC 27611-7687 SHIP TO: NC DEPT. OF ENVIRONMENT 401 OBERLIN ROAD STE 150 RALJ;JJ.:ari-~-NC DATE: PAGE: CODE: _.. ................ 'rt. 27605 FOB: CUSTOMER NEEDS BY: 07/05/99 VPO: --------------------------------------------------------------SHIP YIA:UPS : CUST PO#:DIV. 0572 : TERR #: 12 COD:N -------~----------------------------------------------------------:PREv:a.JR: DATE:, ORO:SHIP:SHP:SHIPPD: I I so:ITEM NUMBER I ' . :GROUP # I I :DESCRIPTION I ' Lex: :cooe --------------------------------- 10 1 I FTG-NSCO ORDERED BY PAT BACKUS919-733-4996 OETIKER CLAMPS CUST~ER RETu'RNED ( 1 ·o) PN 1113 1 /2" HOSE CLAMPS TO EDMAC :-RALEIGH. WRONG SIZE. CREDIT FOR RETURN TO FOLL™. \ 1784 ------------------------------------------ST IF ___ _ LA ____ _ MI ____ _ UP ST ___ _ TO NOTE: ALL RETURNS MUST HAVE PRIOR APPROVAL AND ARE SUBJECT TO A RESTOCK CHARGE. JUN-04-1999 09:44 FROM QED Enuir Systems Tl] 19197334810 P.001/001 ~QB) Environmental Systems, Inc. P.O. Box 3726, Ann Arbor, Michigan 48106 • Web::;ite: http//www.qadenv.com • 734-995-2547• 800-624•2026• Fax: 734-995-1170 CUSTOMER SERVICE FOLLOW UP RESPONSE Acc1t #: 970919151456-SDS To: Pat Backus Company: North Carolina DWM Phone: 919-733-0692 Fax: 919~733-4810 Date: 5/26/1999 Reported Problem With: Solar Controller Dear Pat Backus: We want to make sure that you are completely satisfied with the assistance we provided to you over the phone. If you are not satisfied, or you need further .information on this matter, please contact me at 1-800-624-2026 or fax back this form to 734-995-1170 with the appropriate box marked. l~verything is operating to my satisfaction per QED's troubleshooting assistance. [7 Please contact me; still experiencing difficulties or have additional questions. r--c I ! Other: Si:;•9111~ tvey J. Morrell Customer Service Representative cc: Customer File: 970919151456-SDS TGlEDEquipmentfor ground water sampling, remediation and treatment [DMAC COMPRESSOR COMPANY PO BOX 10489 707D SAl.[M AVENLJ'E WINSTON-SALEM, NC £710 1 SOLD TO: 052366 NC DEPT. OF ENVIRONMENT P. 0. Sox 27687 Ra..te.lf,ft NC 27 611-· 7 687 FOB. CUSTOMER N[E.DS 0[,/07/9S .. ORDER#: 60695 SNIP TO: NC DEPT. OF ENV/WASTE MNGMNT 401 OBERLIN RD, STE 150 RALEIGH NC DAT[: 05/24/99 PAGE: 1 CODE: 5 ATTN: PAT BACKUS 27605 VP'J: SHIP VIA:UPS : CUST PO#:DIV. 0572 1 J TERR #:12 ; COD:N : : ·----------------------------------------------L----------· ------------------------------------:PRrv:cuR: DAT[: j I o;;m:sHIP: SHP;,%IPPD: BO:ZTEN NUMBER fGROUP # 10 / ,-C 4 K D BY: J.:;, • .. 'L_ FTG-NSCO ORDERED BY PAT BACKUS979-733-4996 , I ;DESCRIPTION T/2" OITIKER CLAMPS NOTE: ALL RETURNS MUST HAVE PRIOR APPROVAL AND ,_,R[ SUBJECT ro A RESTOCK CHAR.Gt. I I LOC :coDE I 7!34 ST __ ---··---__ IF _________ _ LA__ -··---·- t1I UP ___________ _ Q E D Environmental Systems, Inc. P.O. BOX 3726 ANN ARBOR, MICHIGAN 48106 TEL: (734) 995-2547 FAX: (734) 995-2125 T .. · :; ..... .._:~j· ... fl, J ~~~ ·:~;• -r~1_1qt~t .1 i~t1r·; ·•i :( .... -; ~ = \:i LN# ITE~/CATALOG ITEM 'r·~:)1.i;::.· l "~'"E'l':l ~ j::: C1 ·Ci....\~.:·; T(1j,~ 1-)c..~·~;c::H r r·, .. r T ~J:·\1 ~ r~tlJ?,1. F :31 ~ ,_'. -•·a.ti _ .. :._, ·11CJi_,.IF' .:: .i .. F: ,ii~ .. _::,, .. _( -:~-~~!~-l,i.);?1 ~:•:···~1C~ !~ T 1:•·r l ;·~:;·.!. UM f . ,· •• I H L I S T ORDER QUANTI TY 4'i~l Lif,r;·:l. .. 1 " ;::':·',f;,ulTc /~0 :;,:::i;_ r·1.-::,.j i,t·· .-.. ·,=-:z1r_-, l r: J · '." ·[:!· _l : :·i I .::;C ~-F,::~ ;: QUANTITY DUE ., J. SHIPPED QUANTITY BACKORDER G!UANTITY PARTIAL SHIPMENT TermUllil_Q_insJitions of Sale ~.J.&sjlla!M Qf.Q.llkl Urders are sub1ect to acceptarn:e in writing by Seller at it, home office. 2 J t:.<ill:,P .. l.11.liill.ll!LT\;!.llli All shipments art• F.O.B. p(lint of or1gm. Seller 1s not responsible for damage ro or loss of goods 111 transit. 3 Pi!~ 1ne..ru. .. Ter..Oll! Unless otherwise stated. net paym,:nt 1s due thirty (30) Jays after shipment. Overdue accounts arc subject to a service charge of 1 1/2% per mnnth. fluye1 shall pay any c•>llrction fees and reaso11ablc artorney 's lees incurred by Seller in collecting payment of the purchase price ,rnJ any other arnoums for which Buyer is liable hereunder. 4. u.ectu Open account terms \viii be extended to tmm with satisfactory commercial credit rating. An open account agreement must be properly filled lllil and signed by an authorized pany. Ju the absence of adequate credit intormation, the order may be shipped C.O.D.. or Prepaid to avoid delay 5 Ta~.anct....E~~ 1'1 ices shown do not reflect any Federal, State. ur Local taxes which now exist or hereafter may be imposed. Orders are accepted with the understanding that such taxes an; !:!1cxK1:s-1i::.s1mmil)ili,ty and will be added as the law requires. The failure of Seller to charge 8uyer tax whe1e applicable Joes not many way 1elieve the Buyer of the tax obligation. 6. Ddi.Yer.):'. Spt:cifit:d delivery dates are approximate and subject ro change. Seller is not responsible for delays due to strikes, fires. government action, ,)I any <Hllt'r causes beyond Seller ·s contrnl. Seller is not liable for loss of use or profit, ur lD interruptions of business activity for any 1ncidt.:ntal or consequential damages re,uit1ng from delayed delive1y or from any other cause. 7. l,j!!.l.ile.cLWillill.11Y...an.d...&!1J~dx The only warra11ties applicable to the items being pu1chased are those set forth 011 the warranty documents. All implied warranties, including wi thout limitation implied warranrie, of merchantability and fitness for a particular purpose, are hereby disclaimed. 8. Cancellat\Qn Atter Seller accepts, no order may be canceled without Seller's written consent. Cancellation, if approved. is contingent upon Buyer's payment to Selle1 as liquidated damages of a charge computed to cover all costs incurred by Seller on terms acceptable to Seller. 9. As:il.lUlJfilJll Neither party 111ay a~sign this agreement withou1 written con~em or the other pa1ty. 1 o . 0m'.!:.111lll.l:.l,aw. All quorntions and sales lJereunder shall he governed and construed in accordance with the imernal laws of the State of Michigan. Exclusive ju11sJiction and venue over any dispute between Seller and Buyer shall exist in t11e federal and state courts located in Washtenaw Coumy. Michigan and Buyer consems to the jurisdiction of such couns. I 1 . W21..llt:.arUrnllLl.!!!.l.CQml.itiQJl~ Buyer's order is acct·pted only 011 the term~ and conditions stated ht:rein. and Seller's acceptance of Buyer's order is expressly made contliuonal upon Buyer's assent to s11di terms and conditinns. Notwithstanding any contrary terms in Buyer's purchase order, the acceptance of QED Env1ronrnental Sy,tems, Im:. products shall conclusively establish the a<;Sent by Buyer to these terms and conditions. No change in or wa1veror modification 11f any or the terms and conditiom. nor any addition or deletion, will be accepted by or binding upon Seller unless in wr1ti11g and signed by Seller's au1horized represe11ta1ive at Seller's home uffice. The terms and conditions herein are intended by the parties as the complete. exclu~ive and final expression of their agreement, and any understandings, representations .. or agreements outside the pruvi~ions of thi~ insti ument do nnt constitute any part of or in no way affect th;~ contract. Buyer's acceptance of goods shall conclusively establish Buyer's assem to 1hese terms and condit1011s. 12. Iille Notwithstanding any other prnvi~ions hereof. title to any equipment intended to be sold hereunder, including all accessories .. other equipment and pares hereinafter attached or suh-aituted ,hall not pass to Buyer, and Seller shall have a security interest. with all rights and privileges 1.hcrei11 . unlil all unpaid sums are fully paid _,- 05 /12/1999 14:40 70437t,243':l F'AGE 01 f ' FAX ESHELM:AN CAROl.iINAS, INC. 1127 Commercial Ave.nue • Char-lotte~ North Carolina 28205 Phone: (704) 376-6408 • .Fa~: (704) 376-2439 DATE TO: May 12, 1999 N.C. Division of Waste Management 401 Oberlin Road Raleigh, NC 2765 ATTN: Ms. Pat Backus SUBJECT: QED Pump Controls Dear Ms. Backus: PAGES: FAX: PHONE: 3 919/73 3-48 10 919/73 3-4996 Ext 308 Attached are two instructions for setting refill and discharge timers on pneumatic controllers for QED pump operation. Instructions are setup for QED's L360 controller but are also applicable for your model C 100 controller. Pumping conditions such as depth of the pump and the tlow of liquid into the well affect the performance of the pump. 1) Set pressure regulator to maximum pressure setting. 2) Set initial timer settings ( 1-3 seconds for di scharge and refill for over l 5 seconds) 3) Measure volume of water discharged in one cycle. This is to insure that your pump is getting a full pump volume and that there is no problem occurring with the pump. Pump stoke volume for the SL6000 pump is 1.3 gallons. Longer refill time may be required to completely fill the pump. · ~-~· 4) Adjust the discharge and then the refill timers as described on the attached instructions. We hope this information is helpful to el.iminate excess air in the discharge and to minim.ize iron oxidation. Steve Tobin has been advised to contact you reference your treatment process. As a starting point we will need to know the water analysis and we will need the know the treatment objectives. Please call if you have further questions. Yours truly , QED ENVIRONMENTAL SYSTEMS, INC. #a~~/- Brevard S. Myers, Jr. Technical Coordinator Eshelman Carolinas, Inc. Representative 05/12/1999 14:40 Ei::;HELMAt,J CARCIL I t,JAS F'AGE 02 9 Pulse PumpTM Pneumatic Pumping System Flow rate optimization Pu lse Pump refill and discharge cycle times can be adjusted to deliver the maximum possible flow rates from your system. Pumping conditions, such as the depth of the pump or the flow rate of liquid into the well. affect the perlormance of the pump. Adjustable cycle timers on the Pu lse Pump controller let you tune the system to your site. Three simple steps help you opti• mize the flow rate. 1. vv th tt"1e purnp operating, set the refill time long (about 15 seconds). Set the d ischarge time st1o ri (1 second for wells sr,allower than 50 feet, 3 seconds for wells 50 to 100 feet, and 5 seconds for wells deeper than 100 feet). Liquid should begin to flow through the discharge line after 5-15 cycles of pumping, depending on H1e depth of the well. Measure the li quid dis- charr1ed during one cycle. The volume o1 H1e liquid will be less than the internal volume capac· ity of H1e pump (see Table for volume capacity of your pump). 2. Increase the discharge time gr-adually, in i /2-second increments, letting the pump go through its cycle 3-5 times after each adjustment. Repeat until you see air bubbles coming H1 roug h the discharge line. Then decrease Hie discharge time slightly to eliminate air bubbles. nm amount discharged per cycle is now close to the internal volume capacit y of the pumo. Discharge cycle optimization is complete . Note: If air and water begin to shoot out hard, the discharge cycle time is too long. Repeat step 2 using shorter increment adjustments (i.e. 1/4 second). Bubbles in the discharge line indicate displacement of liquid in the pump by compressed air from the air source, which means you get less than maximum flow rate. 3. Decrease the refill time gradually, in 1-second increments, and let the pump cycle 3-5 times after each adjustment. Repeat until you see air bubbles coming through the discharge line. Now, increase the refill time slightly to eliminate the bubbles. The amount of liquid discharged per cycle should stil l be close to the internal volume capacity of the pump. Refill cycle optimi- zation is complete. Note: If a ir and water begin to shoot out hard, the refi ll cycle time is too short Set the re fill time long again, and repeat step 3, using shorter time increments. Air in the dischar·qe line means that liquid is d ischarged from the purnp before it is completely filled - Pulse Pump Internal volume, Internal volume, model: Liters Gallons f-----------·---------.. ------· ·-. -·· -.--·•---w~•-•-'• ••.• ~-···---- LP1001 0 65 LP1201 LP1501 LP4600 LP1301 LP1401 C::tp)1i9.""ll : ::L?E, OEO !:nv1~,)nrr~n1a! .1:l)•e;1:.41r1!'-. Inc. \'':'t-;ic,r. ?t:,-2a8. 0.65 0.65 3.50 0.35 o.:35 017 017 0 92 0 09 0,09 QED Environmenta l Systems, Inc. P.O. 8oi; 3?~~6, Ann 4._rt,i'."JI. Ml ,:18101) ~~;,:;'\~.~~65_1t, ~::~n196r1, 313,-995-2~7 In G~n;,:1;;1 5191.;:95.,:·~~~.: MAXIMIZING NON-BLADDER PUMPS 1. TURN REGULATOR FULLY CLOCK•WISE TO MAXIMUM PSI OUTPUT. 2, PUT "OISCHARGE" TIMER ANO "REFILi.." TIMERS ON THE "O" SETTING. 3. USING A GRAOUATEO CYLINOER (APPROPRIATE SIZE TO ACCOMMODATE VOLUME). MEASURE THE VOLUME OF WATER CISCHAROEO IN.ONE CYCI..I, ( THIS IS TO ENSURE THAl YOUR PUMP IS GETTING A FULL PUMP VOLUME ANO THAT THiRE IS NO PROBLEM OCCURlNG WITH THE PUM P ). 3, SET "OISCl·Ul,ROe• CONTROL ON SHORT OISCHARGE: A.FOR WELLS LESS THAN 50 Fr. ser AT "A" SETTING El.FOR WELLS 50.100 Fi. SET AT ·e• SETTINO C.FOR WELLS 100 n. OR DEEPEF\ SET MIDWAY BETWEEN ·s· ANO ·c· SETTlNGS 4. GRAOUALLY INCREASE { IN 1/~ SECONO INCREMENT$) THE "DISCHARGE" TIMER 0 I\IING TH5 PUMP i!ME TO GO THROUGH CYCLES BETWEEN EACH ACJUSTMENT. CONTINUE TO INCREASE THE -oiscHARGE" TIMEA UNTIL AIR BUBBL.ES ARE. SEEN COMING THROUGH THe PUMP Ol5CHARGE AT TH!; ENO OF THE PUMP OISCHAAGE CYCU~ .. AT THI$ POINT SLOWLY CECREASE THE PUMP DISCHAF1G6 TIMER UNTIL AIR BUBBLES ARE NO LONGER S!:E;N AT Tl-IE ENO OF THI: D!SCHAFlGE CYCLE. ~-G!1ACUALLY DECREASE ( IN 1 SECONO INCREMENTS) THE "REFILL" TIMER, GIVING THE PUMP TIME ( TO GO THROUGH 3-5 CYCL.ES BETWEEN EACH AOJUSTMENT. CONTINUE TO DECREASE; UNTIL Al~ E3UBBL.ES ARE SEEN COMING THROUGH THE PUMP DISCHARGE TUSING AT THI; END OF THE DISCHARGE CYCLE. AT THIS POINT SLOWLY INCREASE THE."REFIL.L" TIMER UN'rlL AIR BUBBl..eS AR E NO LONGER SEEN AT THE ENO OF THE CISCHARGE CYCLE. 6. THE PUMr> CONTROLS ARE NOW SET FOA OPTIMUM FL.OW. TIMER SETTINGS ( TIMES ARE APPROXIMATE ) A 8 C D E F I t SECOND 3 SECONOS 9 secoNOS 20 SECONDS 31 SECONDS 42 SECOND$ PUMP CONTROLS DISCHARGE REFILL 1 of 1 http://www.devap.com/cgi-bin/listc ... ?method=city&state=NC&code=RALEIGH ~ --DAPc-.· --------SUPPORT-... -.-.·-, ~ 11 r"' ,f PRODUCTf';fATOII ) . 175:t ,.......,,,.....,,....,......,,.,,.------,.--. Quick Menu ➔ J & STOOL REPAIR 1309 HODGES STREET RALEIGH, NC 27604 Phone: 919-856-0050 Fax: 919-856-0051 Servicing: Power Washers, Air Compressors, Generators ARVIN INC. 5850 FAYETTEVILLE RD. RALEIGH, NC 27603 Phone: 919-779-7404 Fax: 919-773-3673 Servicing: Power Washers, Air Compressors, Generators NORTHERN TOOL & EQUIPMENT INC. 1-40 BUSINESS PARK 1429-114 ROCK QUARRY ROAD RALEIGH, NC 27610 Phone: 919-834-8808 Fax: 919-836-0861 Servicing: Power Washers, Air Compressors, Generators ... Company I Products I Support I Giveaway I Home Development by: Knowledge Link L.L.C. Copyright © 1999 DeV1lb1ss Air Power Company 5/11/99 1 :54 PM ~blast! Blast Central > .. 1 of 1 POWE;Fl!ED BY Sponsored by: lhblfif Clk:k to !Jnd New Location Print Map Save Map Pocket Mapblast! Email Map http:/ /www.mapblast.com/mapblast/b .. .IC=%3A %3A8&IC%3A =J+&+S+ TOOL +REP AIR J -Try our New Mapblast!- 1309 Hodges St Raleigh, NC 27604-1431 Scroll down for more options! Check nearby WEATHER, NEWS, TV listings, or SATELLITE views Home FAQs Feedback I Visit Vicinity Contents Copyright ©1998 Vicinity Corporation. All rights reserved. Use subject to license. US Maps Copyright ©1999 GDT, Inc. Canadian Maps Copyright ©1998 DMTI, Inc. 5/11/99 1 :56 PM ,.. QED Environmental Systems, Inc. 6155 Jackson Road., Ann Arbor, Michigan 48103 ~vnn~ss s~~~~~7l 734-995-2547 800-624-2026 Fax: 734-995-1170 6ii.Arn1.. E-Mail: info@qedenv.com Website: http://www.qedenv.com 12161 Customer Ci -7 0 ·1 I 9 I -· I q s /:; ::us Must Receive On: Acct. No.: _,) ~ r I -I --,.J Please Ship On: Ship To: i .. . ,J ' ,.F VJ{. '",,TC i .' 1 r-Jf"(:.{.. 1-AL·t,jT -,., .. '--f i (No P.0-) ; I U \ ,.,/ ·1 ,( ,:__L , ,✓ h (..,; D Written By: fJ L.S. Boxes -I ·_.o (. (-?-~<;" h 11.Lr i-1 /'J L .. I C c. 1:-Date Shipped: I , :f '-l n · ~f!ention: I ( -, (.,, ;1 c: Kl,,(S / Shipped By: - ' ) Li--' i I -1 --; ~ j -._, -, '-I (c MTS#: .. l n :,;Cb · Phone/Fax: _) J I ·, Part Number QTY Description !Stock Unit Account No. Description I Approval BIN Cost 0 00-600~030 Sales Giveaways-General 1 .:.,;4e;-40 I ,:.:,·, ? VI l Vt LS :-' ... ~ 'u. :;-, D oo-600.s500 Freight Expense-General ~ ., 2 , --~ 110 I I> . ; ( · ----·', 'L l 1~ r 'II I i <. l.i D oo.soo.5401 Quality Corrections-General 3 -,, I 07 I i '1'.. IA I .{;,U D 00-500-5031 Sales Giveaways-Production l:rrons .. t ' \ -1:;S D 00-600-5531 Freight Expense-Production Shipping Errors 4 :.i ··1t;~o I , t I-J f...1 ((""1 l,;f ·,J'r,, v ,/4 f P'T ;~ h -·)i:> D 00-400-5401 Quality Corrections-Production 5 I I Z.(c I '~, j "\ t,,,f L l t".(...,u-. '/ " .\· "f_,,1,:,..·l i i I ~~·] D 20.soo.5032 Sales Giveaways-Remediation 0 20-500~2 Freight Expense-Remediation 6 D 20-500-5401 Quality Corrections-Remediation 7 D 1 o-500-6033 Sales Giveaways-Monitoring 8 0 10-600-6533 Freight Expense-Monitoring 0 10-600-5401 Quality Corrections-Monitoring 9 0 50-530-6034 Sales Giveaways-Treatment 1( D 50-530-6534 Freight Expense-Treabnent D 50-530-5401 Quality Corrections-Treatment Shipping Charges $ D 00-590-5030 Sales Giveaways-International D oo-690-5401 Freight Expense-International U) □ Ground □ 3 Day Select 0 00-590-5500 Quality Corrections-International □ □ 0 00-590-5535 Freight Expense-lntemalional Literature L 2ND Day Air Call Tag D 00-500-5535 Freight Expense-literature ::, □ Next Day Air □ Bill Customer's Account D oo-480-5530 Production Outbound Freight Expense-Vendor 0 00-480-5401 QuaNty Corrections-Purchasing Acct. No. 0 00-610-5500 Freight Expense-Tech Services D oo-&10-5401 Quality Corrections-Tech Services )( □ Economy 0 00-620-5500 Freight Expense-Marketing □ Standard Overnite D oo-&20-5401 Quality Corrections-Marketing Ill 0 00-8901212 Warranty Parts-Service and Repair D [RJ Priority One ~00-690-5401 Quality Corrections-Service and Repairs Ill □ Saturday Delivery 0 D0-690-6030 Giveaways-Service and Repains 0 00-690-5500 Non Warranty Freight Expense-Service&Repairs II. □ Bill Customer's Account ~ 00-690-5510 Warranty Freight Expense-Servlce&Repalrs D 00-120-5550 Freight Expense.Payroll Acct. No. 0 00-850-6500 Freight Expense-Engineering · □ D oo-&00-5030 Giveaways-Field Installations Other Carriers 0 D0-600-6500 Freight Expense-Field Installations 0 D0-600-5401 Quality Corrections-Field Installations If Giveaway, Must Fill Out Reason Whyl □ □ □ □ □ P/N 2017 Rev. #1 11-11~ SPECIALIZING ~ IN MAIN OFFICE □ 1430 TRINITY AVE. P.O. BOX 5406 HIGH POINT. N.C. 27262 PHONE (919) 886-5081 FAX., 919-889-2745 WATTS 800-334-1001 INDUSTRIAL PNEUMATIC AND SPRAY EQUIPMENT H.R. JONES TOOL ft SUPPLY CO.• DIVISION OF AIR POWER, INC. (919) 299-9800 s 0 l D T 0 RALEIGH BRANCH 0 2304 ATLANTIC AVE. P.O. BOX 41165 RALEIGH, N.C. 27629 PHONE (919) 828-9174 FAX., 919-828-0057 WATTS 800-438-4868 TAX I.D. NO. LENOIR BRANCH □ 724 HARRISBURG RD., S.W. P.O. BOX 896 LENOIR. N.C. 28645 PHONE (704) 758-5167 FAX# 704-758-0068 WATTS 800-447-3345 . YOUROP2~ _ L,;,..J {t1I 2 3 4 5 6 SALESMAN QUANTITIES ORDERED SHIPPED /()o() /tJoO I I / I t( lf - lo /IJ I I I I , B/0 12.U _L£' 7E ~I: OE /JA TP ,, SALEM BRANCH 0 AIR POWER OF VIRGINIA, INC. 212 APPERSON DRIVE P.O. BOX 773 SALEM, VIRGINIA 24153 PHONE (703) 389-7261 FAX., 703-389-7268 WATTS 800-848-1011 I YOUR /ER ~ 07-=~ qc/ I TERMS: NET 30 DAYS I MODEL OR PART NUMBER !LM /J 3(;'c; IL /l=-,IJ5 -()?'-CJ# /cf:-P5-D~-Ot; l:/:0~-O1' f</"V1 2 z Z ~,- rz5-1__ I..J/-/Oo ;EP. 'f-~ {l.o ' AJR/oWERmc F R 0 M s H I p T Lb/ D4,,rft,,, tJ :Jv)lc /:;;-o 0 R ?-1&,) '1 ,A/C 27?-oS--1 3'-C> CHATTANOOGA BRANCH 0 1600 EAST 25th ST. CHATTANOOGA, TENN. 37404 PHONE (615) 624-7800 TUPELO BRANCH □ GREENVILLE BRANCH □ FAX" 615-624-9738 WATTS 800-367-9208 PHONE NO. I ACCOUNT NO. 614 ROBERT E. LEE DR. TUPELO. MS. 38801 PHONE (601) 844-0419 FAX" 601°842-4018 WATTS 800-824-1006 JOB NO. DATE SHIPPED 29 WOODRUFF INDUSTRIAL LN. GREENVILLE. S.C. 29607 PHONE (803) 234-5456 FAX., 803-281-0545 WATTS 800-922-7321 I F.O.B. SHIPPING POINT v1A/Jtck-v'j I NET DESCRIPTION PRICE TOTAL . ~ fl --/✓., ,f;:: ,c:rl I I ..t)< t. -/t'll,,.,_.,, ,z..,30 I I I ~_l<( ¾, -/-itrh7 /,,tjg I I I ' ~ )( !! fl~1-t ,,..,,.," ,,)~ Z/f> I :..-l. I c:1~,.,.1?._ ,2~ I I f " /,Jfv; £(t/,,S Cl 7<-Ff{?,,., f-t11Pt::. /~9~ ~ 8 9 10 11 12 13 14 15 -----_,,,.,,.- ' --...__,.,....,... I j , ' ,. -. , .,, 8.0.W. SPECIAL INSTRUCTIONS: .. MERCHANDISE TOTAL B.0.F. TAX I LABOR INVOICE NO. "7?//k .. SHIPPING/ 170830 , CHARGE £ " : -TOTAL ► I .. I ,. I -I BRANCH e'9PY NO RETURNS ACCEPTED WITHOUT PROPER WRITTEN AUTHORIZATION , ,.,,_, ~C CCMPRESSOR COMPANY PCL SOX 181-89 7010 VJIN;;,TON·-SALEM, NC SALEM A\ENUE 27101 SOLD T<'"'. G523fl6 NC DEPT. OF ENVIRONMENT P. ~. Be, .. · 2 7687 Raleigh FOB. NC ~7611-7687 CUSTOMER NEEDS BY: 03/3u/9S SHIP VI:'-: !JPS ;PPEv:cuR: DAfE; ooo:sHIP:SHF':SHIPPD: : CUST PO#.DIV 0561 I l BO; 1 TEM NUMBER ORDER#. 60018 DATE: n3/16/9<? PAGE: CODE SHIP TO. NC DEPT. OF ENVIRONMENT 401 U8ERLIN RD. SUITE 150 RALEIGH. NC ATTN: PAT B,\CKUS 27GOG '/PC>. : TERR#. 9 : COO:N I ' :DESCRIPTION I I LO8 :OJDE --------------·-r--.. -----· ----------------·-------------·------------ l ? j / --1 ___ )_f. .. V F ZG-04-FOO WIL-FJL1 . I (HDERED BY PAT BACKUS (',HIP 3/1 G/99 Xl 3 WI lf<,ER"vCN Fl LTER NCYl: I\L' RFT!JRNS M\lST HAVr: PP10R APPROVAL !i.ND t,RE SUBJECT 10 A PESTO~!' CHARGE:. 0183 LA __ . . -·•---. MI ______ _ UP ST rn .... Particulate Filter F26 Manual Drain Auto Drain F26-02-000 Features • Manual drain. • 5 micron rated element. • Quick-disconnect bowl guard with integral plastic bowl and safety latch. ...---.----B :7 Dimensions Standard Unit F26-XX-000 0 0 Automatic Mechanical Drain F26-XX-F00 D 7.4 188 7.4 188 Specifications Flow Capacity* Maximum Operatin g Temperature Maximum Supply Standard Filtration Useful Retention Port Size Weight 1/4 3/8 1/2 Poly. Bowl Metal Bowl Poly. Bowl Metal Bowl Micron oz. (crt) NPT/BSPP-G lb. (kg) 81.3 scfm (38,3 dm's) 117.8 scfm (55,5 dm'/s) 149.8 scfm (70,6 dm'/s) 125°F (52°C) 175°F (79°C) 150 psig (1 0 bar) 200 psig (14 bar) 5 3.2 (94,6) 1/4, 3/8, 1/2 2.9 (1 ,3) *Inlet pressure 150 psig (10 bar). Pressure drop 5 psid (0,3 bar). "F" Series FiltersType "A" 5 micron elements All Wilkerso n Type "A" 5 micron element 911eet or excem ISO Class 3 for maximum particle size and concentration of solid contaminants. Materials of Construction Body Bowls Deflector Element Retainer Baffle Filter Element (5 micron) Seals Sight Gauge 3.3 84 3.3 84 3.0 76 3.0 76 Plastic Bowl Metal Bowl Plastic Bowl Metal Bowl Metal Bowl 1.0 25.4 1.0 25.4 Zinc Polycarbonate Zinc Polypropylene Acetal Acetal Polypropylene Nitrile Fluorocarbon Nylon 1.53 38.9 1.53 38.9 , . Replacement Bowl Kits Plastic Bowl, Manual Drai n .............................................. GRP-95-929 Metal Bowl, Manual Drai n ................................................ GRP-95-930 Metal Bowl/Sight Gauge, Manual Drai n ........................... GRP-95-931 Plastic Bowl/Guard, Manual Drai n ................................... GRP-95-935 Plastic Bowl/Guard , Automatic Drai n ............................... GRP-95-948 Metal Bowl , Automatic Drai n ............................................ GRP-95-960 Replacement Element Kits Type A 5 Micron ............................................................ ..FRP-95-115 3 Micron Oi I Adsorbing ...................................................... FRP-95-206 Accessories Automatic Mechanical Drai n ............................................ GRP-95-973 @ F26-03-000 <ii "O .c .ui Inlet Pressure C. 15 35 60 90 120 150 pslg 1,0 2,4 4,1 6,2 8,2 10,3 5 0,3 a. 4 0 a: C w 3 a: 0,2 ::::, CJ) CJ) w 2 a: a. 0,1 0 0 0 0 Ordering Information Manual Drain 40 20 80 40 AIR FLOW RATE 1/4 3/8 1/2 120 60 scfm dm3/s F26-02-000 F26-03-000 F26-04-000 <ii .c a. 0 0,3 a: C w a: ::::, CJ) CJ) 0,2 w a: a. 0,1 0 cii .c a. 0,3 0 a: C w a: ::::, 0,2 CJ) CJ) w a: a. 0,1 0 "O .ui C. Inlet Pressure 15 35 60 90 1,0 2,4 4,1 6,2 5 4 3 2 0 20 0 10 "O .ui C. Inlet Pressure 5 4 3 2 0 0 0 F26-02-M00 F26-03-M00 F26-04-M00 40 20 40 20 30 AIR FLOW RATE 15 35 60 1,0 2,4 4,1 80 40 AIR FLOW RATE F26-02-G00 F26-03-G00 F26-04-G00 Optiors -To order an option supplied with the unit model, add the appropriate coded su ffix letter in position 6, 7, 8 of the modemu m For additional information on accessories and repair kits refer to pages 326 through 334. F26-02-000 120 150 8,2 10,3 I 80 scfm 40 dm3/s F26-04-000 90 120 150 6,2 8,2 10,3 120 scfm 60 dm3/s F26-02-D00 F26-03-D00 F26-04-D00 WILKERSON® CORPORATION WARNING DO NOT PLACE PLASTIC BOWL UNIT IN SERVICE WITHOUT METAL BOWL GUARD INSTALLED Plastic bowl units are sold only with metal bowl guards. To minimize the danger of flying fragments in the event of plastic bowl failure. the metal bowl guards should not be removed. If the unit is in service without the metal bowl guard installed, manufacturer's warranties are void, and the manufacturer assumes no responsibility for any resulting loss. IF UNIT HAS BEEN IN SERVICE AND DOES NOT HAVE A METAL BOWL GUARD, ORDER ONE AND INSTALL ONE BEFORE PLACING UNIT BACK IN SERVICE .. For inlormation on materials harmful to plastic bowls. contact a Mobay Chemical or General Electric ottice lor more inlormation regarding materia~ that will attack polycarbonate plastic. CAUTION Certain compressor oils. chemicals. household cleaners. solvents. paints and fumes will attack plastic bowls and can cause bowl failure. Do not use near these materials. When bowl becomes dirty replace bowl or wipe only with clean. dry cloth. Reinstall metal bowl guard or buy and install a metal bowl guard. Immediately replace any crazed, cracked. damaged or deteriorated plastic bowl with a metal bowl or a new plastic bowl and metal bowl guard. EXCEPT as otherwise specified by the manufacturer. this unit is specifically designed for compressed air service. and use with any other fluid (liquid or gas) is a misapplication. For example. use with or injection of certain hazardous liquids or gases in the system (such as alcohol or liquid petroleum gas) could be harmlul to the unit or result in a combustible condition or hazardous external leakage. Manufacturer's warranties are void in the event of misapplication, and manufacturer assumes no responsibility for any resulting loss. Belore using with fluids other than air, or for non· industrial applications. or for life.support systems consult manufacturer for written approval. INSTALLATION 1. Refer to the above warning. 2. Install as close as possible to point where air is being used. 3.lnstall the unit with the air flowing through the body in the direction indicated by arrow. 4. Install the same pipe-size unit as the pipeline in use. Avoid using fittings. couplings, etc., that restrict air flow. 5. Do not install this unit on any application where the pressure drop will exceed 20 psi. 6.A drain line with 1/8" NPT connection may be attached to the drain port if desired. Drain line should be 1/4" tubing or larger, as short as possible, and crimp-free. ?.Maximum inlet pressure and operating temperature ratings are: transparent plastic bowls. 150 psig (10 bar) and 125°F (52°C); metal bowls, 250 psig (17 bar) and 175°F (79°C). 8. Install unit in a vertical position. MAINTENANCE 1. TO CLEAN BOWL OR REPLACE FILTER ELEMENT: a. Depressurize unit. b. Inspect and replace crazed, cracked, damaged or deteriorated seals and bowls with original manufacturer's approved seals and bowls. c. IF BOWL BECOMES DIRTY, replace it or clean it by wiping it with a soft dry cloth. 2. IF UNIT HAS RIGID (FELT) FILTER ELEMENT, replace or clean it periodically. Remove element and tap it on a hard surface. Use an air gun to blow out residual dirt. 3. IF UNIT HAS A OIL REMOVING CLOTH FILTER ELEMENT, replace it with a new one every six months, or sooner if it becomes dirty or causes pressure drop of 10 psi (0,7 bar) or more at rated flow. 4. IF METAL BOWL HAS A MANUAL PETCOCK, drain bowl at least once per work shift. 5. IF BOWL HAS AN AUTOMATIC MECHANICAL DRAIN, clean screen around drain seat whenever elements is cleaned or changed. Remove adapter nut. Remove drain assembly. Use an air gun to blow dirt out of screen and valve assembly. 6. BEFORE PLACING UNIT IN SERVICE, reinstall bowl and bowl guard and lock them securely in place. REPAIR KITS AND REPLACEMENT PARTS Filter element (Type A) and bowl o-ring .................................. FRP-95-115 Element, o-ring, deflector vane and element retainer kit ......... FRP-95-944 Type X oil-removing element kit and bowl o-ring ..................... FRP-95-206 Bulk Pak element kit (Type A) ................................................. GRP-95-268 Bulk Pak element kit (Type X) .................................................. FRP-95-269 Viton bowl o-ring kit ................................................................. GRP-95-900 Transparent plastic bowl assemblies: Plastic bowl with Flex-Drain™ .............................................. GRP-95-929 with bowl guard, Automatic Mechanical Drain .................... GRP-95-948 with bowl guard, Flex-Drain™ .............................................. GRP-95-935 INSTALLATION AND MAINTENANCE SHEET Filter Models F26 with Variations and Accessories FILTER ELEMENT r--· FLEX-DRAIN™i (Plastic Bowls Only) CTIFFERENTIAL ESSURE DICATOR BODY ELEMENT RETAINER FILTER ELEMENT t AUTOMATll:=BOWL ~~;l~ANICA INSERT (Optional) O -RING I t TRANSPARE~T7 PLASTIC BOWL i METAL BOWL GUARD METAL BOWL REPAIR KITS AND REPLACEMENT PARTS CONT. Metal bowl assemblies: with petcock . . ................................................... GRP-95-930 with petcock, sight gauge ..................................................... GRP-95-931 with Automatic Mechanical Drain (Viton seals) .................... GRP-95-960 Drains: Automatic Mechanical Drain ................................................ GRP-95-973 Automatic Mechanical Drain with Viton seals .... .. ... GRP-95-981 Brass petcock kit ..................................................................... GRP-95-182 Flex•Drain™ for plastic bowl .................................................. FRP-95-610 ACCESSORIES Sight Gauge for metal bowl (new style) ... . .................. GRP-95-079 83-849-000 9/95 Printed in the U.S.A. Accessories Filters Piston Drain L-Bracket GPA-ss-016 & GPA-95-946 Cap, Differential Pressure Indicator Differential Pressure Gauge Dimensions Piston Drain GRP-95-584 C04,F00 Differential Pressure DP2-01-000 M16,M21 ,M26,M30,M31,M32 Indicator DP2-01-001 F35,F36,F37,F43,M35,M36 M37,M43 ,M45 Differential Pressure DP3-01-000 F50,F51 ,F52,F53,M32 Gauge DP4-01-000 M50,M51,M52,M53,M55 1.16 29.5 2.12 54 2.12 54 3.0 75.9 Differential Pressure Indicator Automatic Mechanical Drain (Standard and Low Flow Versions) .96 24 1.85 47 1.85 47 2.55 65 .25 6.3 .84 21 1.54 39 Accessories Filter/Regulators ri A--1 E ' LY7 U a1 I L-Bracket , ~__1 GRP-95-147 GRP-95-747 G Automatic Mechanical Drain (Standard and Low Flow Versions) L-Bracke t GPA-95-011 GPA-95-012 Dimensions L-Bracke t GRP-95-754 Wall Mounting Bracket U-Bolt Pipe Clam p GRP-95-734 Accessoria L-Bracket With plastic panel nut Part Numb8' Used On GRP-95-147 C04 GRP-95-747 C04 Inches mm With plastic panel nut GPA-95-011 CB6 & PC5/PC6 GPA-95-012 CB6 & PC5/PC6 GRP-95-754 C04 Auto. Mech. Drain, Nitrile GRP-95-973 CB6 Auto. Mech. Drain, Fluoro GRP-95-981 CB6 Low Flow, Nitrile GRP-96-400 CB6 Low Flow, Fluorocarbon. GRP-96-500 CB6 Other Accessories Description Aluminum Panel Nut Tamper Resistant Kit Part Number RPA-96-733 RPA-96-326 RPA-96-735 RRA-95-006 Used On C04 C04 (HEX.) C04 (RING STYLE) CB6 & PC5/PC6 A 1.50 38 2.50 63.5 1.06 27 2.93 74 B 0.68 17 1.60 41 2.00 51 1.47 37 C 1.00 25 1.50 12 0.82 21 1.17 30 Wall Mounting Bracket-Gauge Port Adapter B RRP-95-590 A RRP-95-591 Le Pressure Gauge D E F G 1.75 0.34 0.31 0.21 44 8.6 7.9 5.1 .46 .62 1.88 1.( 16 24 40 59 1.75 0.28 0.50 44 7.1 13 Eshelman Carolinas, Inc. 1127 Commercial Avenue Charlotte, NC 28205 Invoice Phone 704-376-6408 Fax 704-376-2439 BILL TO N.C. Division of Waste Management Attn: Ms. Patricia Back.7.ls 401 Oberlin Road, Suite 150 Raleigh, NC 27605 P.O. NUMBER TERMS REP DATE 2/24/99 SHIP TO N.C. Division of Waste Management Attn: Ms. Patricia Baclms 401 Oberlin Road, Suite 150 Raleigh, NC 27605 SHIP VIA INVOICE# 1215 F.O .B. 1640019403 Net 30 BSM 2/24/99 FedEx-3rd party Ann Arbor, MI QUANTITY PER l ea. l ea. L ea. L ea. 100 ft. l 00 ft. LOO ft. DESCRIPTION SL6000 QED Landfill Slider Pump & Cable, Attachment Hardware, SS, Teflon, Viton & Delrin construction. 9.5 gpm max. flow. Pump 69" L, 4.5" Dia. 9999,C l 00 Controller with 250A valve for high capacity operation 9999, Exhaust valve, Teflon coated, for 5/8" air line 9999, 6" PVC Slip-fit well cap, with SS eyebolt for use with 1-1/4" discharge, 5/8 air line 37014, 1-1/4" O.D. Nylon Discharge Tubing 37681, 5/8" Nylon Air Line Tubing 37060, 3/16" SS Cable RATE 2,935.00 Total 931.00 123.00 108.00 4.75 1.81 1.67 AMOUNT 2,935 .00 931.00 123 .00 108.00 475.00 181.00 167.00 $4,920.00 - I Ch1..nys l'o/1>r. WILKERSON® CORPORATION WARNING DO NOT PLACE PLASTIC BOWL UNIT IN SERVICE WITHOUT METAL BOWL GUARD INSTALLED Plastic bowl units are sold only wfth metal bowl guards. To minimize the danger of flying fragments in the event of plastic bowl failure, the metal bowl guards should not be removed. If the unft is in serYice without the metal bowl guard installed, manufacturer's warranties are void, and the manufacturer assumes no responsibilfty for any resutting loss. IF UNIT HAS BEEN IN SERVICE AND DOES NOT HAVE A METAL BOWL GUARD, ORDER ONE AND INSTALL BEFORE PLACING BACK IN SERVICE .. CAUTION Certain compressor oils, chemicals, household cleaners, sotvenls, paints and fum es will attack plastic bowls and can cause bowl failure. Do not use near these materials. When bowl becomes dirty replace bowl or wipe only with clean. dry cloth. Reinstall metal bowl guard or buy and install a metal bowl guard. Immediately replace any crazed, cracked, damaged or deteriorated plastic bowl with a metal bowl or a new plaslic bowl and metal bowl guard. WE CANNOT POSSIBLY LIST ALL HARMFUL SUBSTANCES .CHECK WITH A MOBAY CHEMICAL OR GENERAL ELECTRIC OFFICE FOR FURTHER INFORMATION ON POLYCARBONATE PLASTIC. EXCEPT as otherwise specified by the manulaclurer, this producl is specifically designed for compressed air service, and use w~h any other fluid (liquid or gas) is a misapplication. For example, use with or injeclion of certain hazardous liquids or gases in the system (such as alcohol or liquid petroleum gas) could be harmful to the unit or result in a combustible condition or hazardous external leakage Manufacturer's warranties are void in the even! of misapplication, and manufacturer assumes no responsibilily for any resulting loss. Before using wilh fluids other than air, or for non-industrial applications, consult manufacturer for written approval. INSTALLATION 1. Refer to warning. 2. Purge downstream air line of oil. 3. Install as close as possible to where regulated air is being used. 4.lnstall the unit with the air flowing in the direction indicated by the arrow on the body. 5.A drain line with 1/8" NPT connection may be attached to drain port if desired. Drain line should be 1/4' tubing or larger, as short as possible, and crimp free. 6. Maximum inlet pressure and operating temperature ratings are: transparent plastic bowls, 150 psig (10,3 bar) and 125'F (52'C); metal bowls, 150 psig (10,3 bar) and 150'F (66'C). TYPICAL INSTALLATION (notto scale) B A. PREF IL TER -It is recommended that a Wilkerson 5-micron-rated prefilter be installed upstream from the coalesce, filter to prolong element life. B. AIR DRYER -(Refrigerative or Twin Tower). An air dryer is generally preferred for optimum results, but is optional. C. COALESCER FILTER -Do not touch the filter element once it has been put into service; the slightest pressure on the outer foam cover can easily damage it once it has been used. D. AC PAK -The Type D element is an adsorption type for removing oil vapors. Oil-associated odors, whether petroleum base or synthetic base, and nearly 100% of any removing solid contaminants are removed. ~ E. DIFFERENTIAL PRESSURE INDICATOR -Maximum recommended pressure drop across coalesce, filters is 7 psi (0,5 bar). This can be monitored by installing a Wilkerson differential pressure indicator. F. VALVE - Do not use a valve or shutoff device in conjunction with a coalesce, filter that will allow a momentary or surge pressure drop greater than 50 psi (3,4 bar). To avoid high surges which can either ruin the element or momentarily allow downstream contamination, use a slow-opening type valve. MAINTENANCE 1. The element operates effectively when it is saturated. The element's useful life will end only when the resistance to flow becomes too high or the maximum permissible pressure is reached. The element cannot be cleaned or reused and must be replaced at the end of its useful life. INSTALLATION AND MAINTENANCE SHEET Coalescing Filter Model M26 with Variations and Accessories OIFFERENTIAL--,-,-.-.,-,----, PRESSURE INDICCTOR BODY ,.,,,,-BOWL □PLATE ..,--~~~y N:RASKET i]"' 0-RING FILTER ELEMENT TYPE B OR TYPEC _l__ FLEX-DRAIN™ (plastic bow~ onlyy TRANSPARENT BOWL BOWL GUARD ;--,-, AUTOMATIC MECHANICAL DRAIN 0-RING MAINTENANCE cont. BOWL? 0-RING 0-RING I I NUT ____,Im, 1.--:_ GASKET FILTER ELEMENT TYPED BOWL INSERT -.,l AUTOMATIC 0-RING N MECIHANICAL I I METAL BOWL ~INSERT RETAINEF I ~ PETCOCI 2.IF THE UNIT HAS A MANUAL DRAIN, drain the unit once every 8 hours. IF UNIT IS EQUIPPED WITH AN AUTOMATI C MECHANICAL DRAIN, clean the screen around the drain seat each time the element is cleaned or replace it by removing the nut and removing the drain assembly. Clean screen by blowing off with air blow gun. 3. When bowl becomes dirty, replace the bowl or clean by wiping with a dry, clean doth. 4.Before placing the unit in service, make sure that the bowl and bowl guard are reinstalled, and securely locked in place. REPAIR KITS AND REPLACEMENT PARTS Bowl O-Ring Kit ..........................................................•........... GRP-95-955 Type D Element Kit... ...........................•........ . ...... MXP-95-540 Type C Element Kit.... . .....................................••........... MIP-95-549 Flex-Drain™......................... . .................•.................... F.RP-95-610 Automatic Mechanical Drain (w/Viton Seals) ................. , .•.......... .GRP-95-981 Automatic Mechanical Drain .................................................... GRP-95-973 Plastic Bowl ............................................................•................. GRP-95-929 with Flex-Drain™ w/bowl guard ..................................•.......... GRP-95-935 with Auto. Mech. Drain and Viton Seals ......•......... GRP-95-948 Bowl Guard.... .................................... . ......... GRP-95-936 Metal Bowl w/Manual Drain ........................... . . .... GRP-95-930 with Auto. Mech. Drain & Viton seals ..... . . ....... GRP-95-960 Differential Pressure Indicator ................................ . . ..... D.P2-01-000 ACCESSORIES Wall Mounting Bracket ......................... . . ... GP.A-95-946 83-055-000 REV REL 6/91 Printed in U.S.A. Coalescing Filter M26 Coalescing Filter Auto Drain M26-02-000 Features • Manual drain. • 0.01 micron rated filter element. • Quick-disconnect bowl guard with integral plastic bowl and safety latch. • Differential pressure indicator. ·;1 A 0 0 0 0 0 Dimensions Models Automatic Mechanical Drain M26-XX-F00 Inches mm --c I) _l A 8.2 208 Specifications Flow Capacity* Maximum Operating Temperature Maximum Supply Pressure Standard Filtration 1/4 3/8 1/2 Poly. Bowl Metal Bowl Poly. Bowl Metal Bowl Micron 55.0 scfm (25,9 dm'/s) 65.5 scfm (30,9 dm'/s) 79.5 scfm (37,5 dm'/s) 125'F (52'C) 175'F (79'C) 150 psig (10 bar) 200 psig ( 14 bar) (B) 0.5, (C) 0.01 (D) 0.003 ppm wt** ---·········································-·················································-·· Useful Retention oz. (cm') 1.7 (51,5) Port Size NPT/BSPP-G 1/4, 3/8, 1/2 Weight lb. (kg) 2.4 (1 , 1) *Inlet pressure 150 psig (10 bar). Pressure drop 3 psid (0,2 bar). **Filtration temperature of 70'F (21 'C)@ 100 psig (7 bar) with typical compressor lubricating oil and protected by Type C filter. "M" Series Coalescing Filters, with Type "B" 0.5 micron elements: All Wilkerson Type 'M' Oil Removal (Coalescing) Filters with Type 'B' 0.5 micron elements exceed ISO Class 2 for maximum particle size and concentration of solid contaminants, and exceed Class 3 on maximum oil content (ppm/wt). "M" Series Coalescing Filters, with Type "C" 0.01 micron elements: All Wilkerson Type 'M' Oil Removal (Coalescing) Filters with Type 'C' 0.01 micron elements exceed ISO Class 1 for maximum particle size and concentration of solid contaminants, and exceed Class 1 on maximum oil content (ppm/w t). "M" Series Absorption Filters, with Type "D" activated carbon elements: All Wilkerson Type 'M' Absorp tion Filters with Type 'D' activated carbon elements exceed ISO Class 1 on maximum oil content (ppm/wt). Materials of Construction Body Bowls Element Retainer Filter Elements Seals B 3.3 84 C 3,0 76 Plastic Bowl Metal Bowl Type B, C Type D D 1.9 48 Zinc Polycarbonate Zinc Brass Stud Borosilicate Cloth Activated Carbon Fluorocarbon E 1.53 38.9 Replacement Bowl Kits M26-02-000 Plastic Bowl, Manual Drain .............................................. GRP-95-929 lii "O ·;;; .c C. Inlet Pressure Plastic Bowl/Guard Manual Drain .................................... GRP-95-935 Metal Bowl, Manual Drain ................................................ GRP-95-930 pslg 15 35 60 90 100 120 150 bar 1,0 2,4 4,1 6,2 7, 0 8,2 10,3 Plastic Bowl/Guard Automatic Drain ................................ GRP-95-948 3 IL Metal Bowl, Automatic Drain ............................................ GRP-95-960 0 0,2 a: 0 Replacement Element Kits w a: 2 ::::, CJ) Type B 0.5 Micron ............................................................ MSP-95-989 Type C 0.01 Micron .......................................................... MTP-95-549 CJ) w a: 0,1 IL Type D Oil Vapor Removing ............................................. MXP-95-540 Accessories Wall Mounting Bracket, L-Type ......................................... GPA-95-946 Automatic Mechanical Drain ............................................ GRP-95-973 0 10 20 30 40 50 sdm Manual Flex-Tip ................................................................ FRP-95-610 Differential Pressure lndicator .......................................... .DP2-01-000 0 5 10 15 20 Cap, Differential Pressure Indicator (for pressures AIR FLOW RATE over 150 psig) ................................................................ GRP-95-020 Drain , Manual Override for Auto Float Drains with 1/8 NPT Port.. ................................................................ GRP-96-000 M26-03-000 M26-04-000 lii 'O .c -~ Inlet Pressure ~ "O "' ·;;; Inlet Pressure .c C. pslg 15 35 60 90 100 120 150 pslg 15 35 60 90 100 120 150 bar 1.0 2.4 4,1 6,2 7,0 8,2 10,3 bar 1,0 2,4 4,1 6,2 7,0 8,2 10,3 3 3 IL 0 0,2 a: IL 0,2 0 0 a: w C a: 2 ::::, w 2 a: CJ) CJ) w a: 0,1 IL :> a, Ill w 0,1 a: IL 0 0 0 0 0 10 20 30 40 50 60 70 sdm 0 20 40 60 80 sdm 0 5 10 15 20 25 30 dm3/s 0 10 20 30 40 dm3/s AIR FLOW RATE AIR FLOW RATE Ordering Information :: : =) ,11~~11 : =:,}, _ :11]1,111;~1r :r;1~111]:: Manual Drain 1/4 3/8 1/2 M26-02-000 M26-03-000 M26-04-000 M26-02-M00 M26-03-M00 M26-04-M00 M26-02-S00 M26-03-S00 M26-04-S00 Options· To order an option supplied with the unit model, add the appropriate coded suffix letter in position 6, 7, 8 of the model number. For additional information on accessori es and repair kits refer to pages 326 through 334. M26-02-X00 M26-03-X00 M26-04-X00 .,, .,, .,, ......... 111111111 111111111 :z: :z: :c .,,.,,.,, 000 11100 -N -N"' "'"'"' ---NNN NNN - ---- ..... - Oo ~ DATE: TO: CC: FROM: RE: 2/19/99 MIKE KELLY INTEROFFICE MEMO ED MUSSLER, LARRY ROSE, MATT GAMBLE PAT BACKUS IMPROVEMENTS TO LEAGIATE PUMPING AT WARREN COUNTY PCB LANDFILL As you are aware, the State of North Carolina must upgrade the leachate collection system at the PCB Landfill in Warren County to address a Notice of Non-Compliance (Docket Number TSCA-4- 97-11844) from EPA Region IV. The original NON required action by August 28, 1998. EPA granted a six-month extension until February 28, 1999 to complete the work. In order to comply with the notice and avoid a violation, the State needs to have a new leachate pump in place and operating by the 281h. Over the past few days, Ed, Larry, and Matt along with you and I have reviewed several options for the upgrade. Our selected option includes purchasing a new pneumatic slider pump and associated equipment. The pump will be insened in the 6" sloped riser from the sump and is designed to deliver up to 9.5 gpm at 200 ft of head. The pump is designed for this specific service and is constructed of materials that will ensure that it not only meets our immediate need to have a system in by the end of next week, but will also serve well until the detoxification is underway. A controller will also be purchased which will tum the pump on and off in response to changes in level in the sump. This is needed to comply with EPA's requirement in the NON that the system be "designed to operate on a more-or-less continuous basis. Because this is a pneumatic pump, an air compressor and dryer will be needed to supply air to run the unit and electricity will be needed to run the compressor. At present the electricity at the landfill stops at the edge of the landfill and is approximately 1000 ft from the leachate pumping and treatment area. Having power lines run to the area will require more time than the State has to complete the upgrade. As an alternative, the group has proposed that the compressor be located near the existing power supply and that an air supply line be run to the pump at the leachate pumping and treatment area. A small building (8' x 8') would be needed to protect the compressor from environmental conditions and from theft. To complete the project, a flowmeter would also be added to monitor the amount of leachate removed from the landfill. Items for this project that exceed $750 are the pump and air supply lines for the compressor. These items are listed in Table 1. Table 2 lists items less that $750. Three written estimates for the pump are also attached. Please review this information and call me if there are any questions. TABLE 1 Estimate of Items > $750 for Uperade of Leachate Pumpine System Materials ******************* Slider landfill pump with controller and associated parts ½" ID air supply line, 1000 ft ******************* 02119199 PMB TOTAL PCB Landfill, Warren County Suppliers ************************ QED Environmental Systems P.O. Box 3726 Ann Arbor, MI 48106 1-800-624-2026 Eshelman Carolinas, Inc. 1127 Commercial Avenue Charlotte, NC 28205 (704)376-6408 Fox Environmental Co. P.O. Box 24009 Evergreen Postal Outlet Kitchener, Ontario, Canada N2M 5Pl (519)725-0009 Air Power Inc. 2304 Atlantic A venue Raleigh, NC 828-9174 James McGraw Inc. 1235 Wicker Dr. Raleigh, NC 833-5584 EdMac Compressor Co. 3200 Lake Woodard Dr. Raleigh, NC 212-3789 ************************ Quote Low Quote ***** ************ $5020 $4920 $4920 $5325 $0.91 per ft $910 $1.18 per ft $1180 $0.90 $900 per ft $900 ***** ************ $5820 02/19/99 PMB TABLE 2 Estimate of Items < $750 for Up2rade of Leachate Pumpin2 System PCB Landfill, Warren County Materials Estimate ********************************** ************* Air compressor $400 60 gal, 6.5 10.5 scfm @ 90psi 240V, 15 amp @ 60 Hz single phase Max pressure= 125 psi Air Dryer $90 Shed to protect compressor $300 Fittings for air supply lines $30 PVC conduit to protect air lines from $30 compressor to fence Flowmeter $100 Miscellaneous supplies $200 ********************************** ************* TOTAL $1150 F~B.18.1939 2:50PM QED ENVIRONMENTAL SYSTEMS N0.755 ESTIMATE# R0299-24399 To: Ed Mussier ~QED ENVIRONMENTAL SYSTEM~ INC. P.O. Box 3726 Ann Arbor, Ml 481015 Phone: 1-800-624-2026 fax: 1-734-995-11 iO Your QED Rep: Steve Tobin Fcbru.:iry 18, 1999 ~ortb Carolina Division of Waste Management 401 Obcrlin Rd. Eshelman Carolinas Inc. Raleigh, NC 27605 Pho:ie: 919-733-0692 Fax: 919-733-4810 Phone: 704-376-6408 Fax: 704-376-2439 Prepared by: Brw1 Root Product Description I PaTT Number l!nit Pric~ Extended Pric;: I) E.A 2) EA EA EA 5) 100 FT 6) 100 FT 7) 100 EA Slicer Landfill Pun:p. All pneumatic, des~ed for sloped well rise:-s. M2~e:-ia!s: S:a:ruess steeL Teflon, Vitoi::., Delri:l. Max:irrrum flow 9.5 GPM. Pi:mp l:!:lgth 69", 4.5" O.D. Includes cable Dt:.ichrnen: hardw:rre. SL6000 ---------------------------------__ 2,995.00 Typically used in coDjUllction ...,;th High Capacity or A1?h.i-s:yle Ferret fo. Well Separators. Contrell~ can be powered by sunligb.~ or 110 volt power outlet btr::J..Sicilly sa::? in solar po~:ered mode. Compact size and en\ironmental;y se:!led 1:2.Se make it suitable for O'Jtdoor remote use. Solar bane;y proYices l O cays o:reserve PO\>.':?:. This conrro!lar wil! include a 250A valve for high capacity opa.:.tion. c,oo ------------------------------------ Pdse Pun:;i Custo:::n Product Special 6" PVC Slip ffr well cap. Supports Slider pump 1 1 /4 •· Liquid discharge and 5/S'' air suppZv lines. Also in.eludes S.S. eyeboltfor the anacr.mer.t oj bra:.lied srainless steel suppon cable. PP-CUSTOM _______________________________ _ Pulse P.JmP Custoo P:oduc: Special Te;7on-coarcd Slider Pump Exhaust Valve. Compatible w'ith 5/8" air supply linC!. PP-CUSTOM -------------------------------- 1-1 /4" O.D. nylon discbuge tubmg. 37014 -------------------__ --------_ ---_ -- s:s~ Nylon Tubing. 37681 --------------------------_ --------_ Stainless steel cable, 3i16". t:'sed with 4" Hammerhead pumps and required for pump de;,ths greater than 100 feet. 37060 ------------------------------------ 950.00 1 !0.00 115.00 4.85 1.85 1.70 E-i:r.ail: info@qedenv.com QED website: ht:p: //..,,..,,..,,,. qed:nv. com 2,995.00 950 .00 110.0·) 125.0Q ~85.00 185.00 170.00 Page 1 Qi:..lJ i:..NV l ~Ul'il'lt:..1'11 r-iL :::::> l::::, r t:..I :::, I 1\,,," • I -·-· ' . .., ~QED ENVIRONMENTAL SYSTEMS, INC. ESTL'1.ATE # R0299-24399 P.O. Box 3726 Ann Arbor, MI 4$106 Phone: 1-800-624-2026 Fax: 1-iH-995-1170 February 18. 1999 To: Ed Mussier No:-th Carolina Division of Waste Management 40 I Oberlin Rd. Raleigh. ~C 27605 Phone: 9 I 9-i~ 3-0692 Flx: 919-733-4810 Your QED Rep: Steve Tobie Eshelman Carolin:is Inc. Phone: 704-376-640S Fax: 704-376-2439 Prepared by: Brian Root • ~>, . --~·~:-:_, ,,, -~,,. P:-oduct Drn:ription / Part 'Kµmber U:tit Price Exrqded P~i;e I:STIMATE TOTAL OPTTO~ 4J,.IT[\!(i:.) S) l EA Level Mare, liq'Jid kvel control :nodule witl: gauge. t:sed in co:nbi:mion with o:::ie Pulse Sender. L375 -------------------------------------855.00 9) 100 FT G:?.Sofo:ie resist?.:Jt, CV pro:e:red, black nylo:i t\!:,ing, 1/4" OD. 35715 -----------------------------------_ 0.85 Terms & Cond1tlor.s: Estimated Shipp ing T:me 1-2 weeJ:.s after receipt of Purchase O,·der. Final delivery date will be detcnninr:d at time of order. All pr:"ces are in U.S. dollars, FOB Ann Arbor, MI, L'.SA. A copy of your purchase order is required at nme oj order. "Pricing and Delivery on all specials ,,,..;/l he determined after receipt of ordl!T'." PtI}m(!Tlf renr.s arr: Ner 30 days wirh appro\'ed credit. Total price DOES NOT include applicable sales tax or freight. A servic:e charge oj 1.5% per monrh will be applied to all pa.st due invoices. Pricing valid for 30 days. After seller accepts, NO order may be canceled witJu:iut Seller's written co,isent. Cancellation, if approved, is subjecr to reasonable restocking and/or handlingjr:e. All products Y.ril/ be returned freight prepaid ro Seller'sfaciliry. Accepted~~--Title: Prim Name: _______________ Corr.pony: ______________ _ PO Number: _______________ Dare: ______________ _ [Hard copy of PO required before shipm<tnt} E-mail: info@qedenv.com QED website: http://www. q:eci.env. com 5.020.00 SS.5 .00 85 .00 Page 2 02/19/1999 12 :16 704376243':l FAX ESHELl\tL\N CAROLINAS, INC. 1127 Commercial Avenue• Charlotte, North Carolina 28205 Phone: (704) 376-6408 • Fax: (704) 376-2439 DATE: TO: February 19, 1999 N.C. Division of Waste Management 401 Oberlin Road Raleigh, NC 2765 ATTN: Ms. Pat Backus SUBJECT: QED Slider Pup & Accessories Dear Ms . Backus: PAGES: FAX: PHONE: _,,- .. # .:> ·'..>--:· . . -~:.:.~~-.:,. 9 l 9!7i'3~48 i 0 919/733-4996 Ext 308 See attached quote for QED Slider Pump model SL60 00 manufactured by QED Environmental Systems, Inc. System includes pump dov.n well tubing and cap. As an option QED modeJ L3 75 level mate is shov.'Il for on/off pump level control. Level is sensed with a bubbler line connected to the L3 75 module. Orders may be directed to: Eshelman Carolinas, Inc. 1127 Commercial Avenue Charlotte, NC 28205 Fax 704/376-2439 If purchase is ;Xempt from ti"'{ation, please provide that documentation with order. Please call if you have questions. Yours truly, ESHELJvl~"'\f CAROLINAS, INC. ~~I Breva1i:.s-: Myers·,_ Jr. Technical Coordinator TO: ESHELMAN CAROLINAS, INC. 1127 Commercial Avenue Charlotte, North Carolina 28205 Phone: (704) 376-6408 Fax: (704) 3 76-2439 N.C. Division of Waste Management 40 I Oberlin Road Quotation Date: Reference: Raleigh, NC 27650 ATTN: Ms. Pat Backus Fax 919/733-4810 Ph 919/733-4996 Ext 308 Item Qty. Model Description No. No. QED Slider Pump and Accessories, QED Part numbers are sh0Vvt1 Februruy 19, 1999 Unit Total Price 1 l SL6000 QED Landfill Slider Pump & Cable attachment $2,935.00 $2,935 .00 hardware, SS, Teflon, Viton, and Delrin Construction. 9.5 gpm max. flow. Pump 69" L, 4.5" Dia 2 l 9999 C 100 ·controller with 250A valve for high capacity 931.00 931.00 operation 3 1 9999 Exhaust valve Teflon coated, for 5/8" air line 123.00 ] 23.00 4 9999 6" PVC slip fit well cap, w/ s.s. eyebolt 108.00 108.00 for use with 1-1/4" discharge, 5/8" air line 5 100 ft 3 7014 l-1/4" O.D. nylon discharge tubing 4. 75 /ft 475.00 6 l 00 ft 3 7681 5/8" Nylon air line tubing 1. 81 /ft 181.00 7 l 00 ft 37060 3/16" SS c:ible 1.67 /ft 167 00 TOTAL S4,920.00 8 1 1375 Level mate, level control module 834.00 834 .00 9 l 00 ft 35715 1/4" 0 .D. nylon bubbler line tubing 0.83 83 .00 Estimated ume for shipment of this product is 1-2 weeks after receipt of order. All prices are in U.S. dollars, FOB Ann Arbor~,, an~ do not include, shipping, applicable taxes, and/or field service, unless specified in our proposal. Terms are net 30 days. Quotation valid for 30 days from above date. Attached Terms & Conditions are included as part of this quote. ESHELMAN CAROLINAS, INC. ~4-/ Brevard S. Myers, Jr. -Technical ~dinator From: J;imes Fox To: Pat Backus Date: 19-02-99 Time: 11 :29:38 AM Page 1 of 1 FOX Environmental Co. Phone (519) 371 , 507 • Fax (5191 ~;:1-er, 5 72.-,. coo'1 7 2..-;. O::>~~ ;\onh Carolina Division of Waste Managment 401 Oberlin Road Raleigh, NC 27605 F ebrua.·y I 9th I 999 Attention: Pat Backus We th:mk :,·ou for your enquiry re a Leachate pwnping system and are please to quote as follows. l -Lec:::hate pumping package consisting of: 1 -Slider pump SL600 1 -AC/DC Controller Cl 00 l -Special 6" PVC Slip cap 1 -Tdlon coated Slider exhaust Valve 1 00' .. J .. J /.f" ~ylon Discharge tubing l 00' .. 5/8" :"-lylon tubing 100' .. Stainless Steel cable 3/16'' Total ...................................................................................... --$5325.00 Pat, these ;:i~ices :ire FOB A.nn Arbor \11. all laxes extra where applicable. I have checked with the Facto0 ::ire th: components are 3]) ex stock. Ple:::s~ cal l ::ic if you have any questiuns 02/19/1999 12:16 ' • 1 ,. DATE: TO: 7043762439 Ei3HELMAH C:AROLIHAS FAX ESHELMAN CAROLINAS, INC. 1127 Commercial Avenue• Charlotte, No . .-th Carolina 28205 Phone: (704) 376-6408 • Fax: (704) 376-2439 February 19, 1999 N.C. Division of Waste Management 401 Oberlin Road Raleigh, NC 2765 PAGES~ FAX: PHONE: ATTN: Ms. Pat Backus SUBJ.ECT: QED Slider Pup & Accessories Dear Ms. Backus: PA(3E 01 919/733 -4810 919/733-4996 Ext 308 See attached quote for QED Slider Pump model SL6000 manufactured by QED Environmental Systems, Inc. System includes pump down well tubing and cap. As an option QED model L375 level mate is shown for on/off pump level control. Level is sensed with a bubbler line connected to the L3 75 module. Orders may be directed to: Eshelman Carolinas, Inc. 1127 Commercial Avenue Charlotte, NC 28205 Fax 704/376-2439 If purchase is exempt from taxation, please provide that documentation with order. Please call if you have questions. Yours truly, ESHELMAN CAROLINAS, INC. ~~I Brevard S. Myers, Jr. Technical Coordinator 02/19/1999 12:15 7043752439 ESHELMAN CAROLINAS ESHELMAN CARO.LINAS, INC. 1127 Commercial Avenue Charlotte, North Carolina 28205 Phone: (704) 376~6408 Fax: (704) 376-2439 PAGE El2 TO: N .C. Division of Waste Management 40 I Oberlin Road Quotation Date: February 19, 1999 Raleigh, NC 27650 ATTN: Ms. Pat Backus Fax 919/733-4810 Item Qty. Model Description No. No. Reference: Ph 919/733-4996 Ext 308 Unit Price QED Slider Pump and Accessories, QED Part numbers are shown 1 1 SL6000 QED Landfill Slider Pump & Cable attachment $2,935 .00 hardware, SS, Teflon, Viton, and Delrin Construction. 9 .5 gpm max. flow. Pump 69u L, 4.5" Dia. 2 l 9999 CI 00 controller with 250A valve for high capacity 931.00 operation 3 1 9999 Exhaust valve Teflon coated, for 5/8" air line 123.00 4 l 9999 6" PVC slip fit well cap, w/ s.s. eyebolt 108.00 for use with 1-1/4" discharge, 5/8" air line 5 100 ft 37014 l-1/4" O.D. nylon discharge tubing 4.75 /ft 6 100 ft 37681 5/8" Nylon air line tubing 1.81 /ft 7 100 ft 37060 3/16" SS cable L67 /ft TOTAL 8 1 L375 Level mate, level control module 834,00 9 100 ft 35715 1/411 O.D. nylon bubbler line tubing 0.83 Total $2,935.00 931.00 123.00 108.00 475.00 181.00 167.00 $4,920.00 834.00 83 .00 Estimated time for shipment of this product is 1-2 weeks after receipt of order. AH prices are in U.S. dollars, FOB Ann Arbor> :MI, and do not include, shipping, applicable truces. and/or field service, unless specified in our proposal. Terms are net 30 days. Quotation valid for 30 days from above date. Attached Terms & Conditions are included as part of this quote. ESHELMAN CAROLINAS, INC. L ~- Brevard S. Myers, Jr. -Tech~ tor U 17,(~ j ~, l h ! 02/19/1999 12 :15 7043752439 ESHELMAH CAROLI HAS PAGE 03 5LC.o oo TECHNICAL DATA/ SPECIFICATIONS SHEET SLIDEil PUMP 1nd':-eo~~::;:.~a:::e7,:ump ;;::::;ump ----L AIR SUPPLY -J~lr-LIQUID DISCHARGE UPPER CHECK BALL Specifications: Pump Type: Posttlve Air Olsplccement Dimensions: Materials: Fittings: Tubing: Pump O.D.: 4.s· Length: 69" Weight: 30 lbs. Stainless Steel, High Density Polyethylene, Teflon Check Bells and Vtton O-Rlngs. Upper Check Ball Insert Delrln (Aceto!) Type: Stainless Steel Barb (Discharge) Stainless Steel Compression (Air Supply) Discharge Size: 1.2· o.o. Air Supply Size: s1a· o.o. "OPTIONAL 1/4• BUBBl.!R UNE TUBING AVAILABLE UPON REQUEST PUMP PEllFORMANCE:: OPERATING PRESSURE RANGE: 0-100 P.s.1. MAXIMUM LIFT: 200 FEET MAXIMUM FLOW RATE: 9,5 G.P.M. PUMP STROKE VOLUME: 1.3 GALLONS PUMP FLOW RATES: AT 100 P.5.1. ON A 3:1 SLOPE ----20' suaMERGENCE • ■ • Ill' • ---10· SUBMERGENCE 2' SUBMERGENCE 7.0 5.0 3.0 OiiSUmpflon( .C.F.M. At 100 P.S.I.G. ACCESSORIES: P/N 9999 EXHAUST VALVE P /N 9999 WELL CAP P/N 37060 CABLE-3/16' STAINLESS STEEL 02/19/1999 12:15 7043752439 ESHELMAt'-1 CAROL I t'-1AS PAGE 04 ESHELMAN CAROLINAS, INC. 1127 Commercial Avenue Charlotte, N.C. 28205 704/376-6408 Standard Terms And Conditions Prices are finn for 30 days unless stated otherwise. Prices FOB shipping point unless stated otherwise. 1. CredJt Tem1s Any order ~fvar~ed t~ EC is subject to cre:dit a~proval by EC. If ?C so requests,_ Buyer agrees to execute and ?ehver to ~C a Secunry Agreement and F1_nanc1ng Statement contom11ng to applicable cornmcrc1al law cover- ing the 1te s sold hcrem. EC reserves the nght to require payment m advance. A 1 1/2 % r month service charge shall be assessed Buyer on any amount due and not paid within thirty days of due date, nd Buyer assumes and agrees to pay same if assessed. All collection or attorney's and/or court costs incurred y EC in collecting the account which is not paid in accordance with the agreed payment terms shall be borne y Buyer. 2. Dut and Taxes The price quoted herein shall be increased without notice by the amount of any tax or duty of any kind levied or proposed under present or future laws either by any federal, state, municipal, or other governmental authority upon the goods or upon EC by reason of the performance of this order. Sales taxes are not included unless seated otherwise. 3. Warranty For a period of 12 months from the date of shipment EC warran.ts that the equipment covered by tliis order shall be free of defects in material and workmanship under normal use and service, and when properly installed. EC agrees to repair or replace F .0. B. point of shipment, such equipment, or any part thereof, previously furnished by EC as actually found by EC after inspection as defective, provided: (a) said equipment has been properly in- stalled, operated and maintained by Buyer in accordance with recommendations, and (b) Buyet notifies EC in writing as soon as any such defect becomes apparent. Any claim by Buyer with reference to the equipment sold hereunder for any cause shall be deemed waived by Buyer unless submitted to EC in writing within 15 days from the date Buyer discovered or should have discovered, any claimed breach. Unless agreed to the contrary by EC in writing, any work done, material furnished, repairs or designs made by others, shall void the warranty. EC shall not be liable for incidental or consequential losses, damages or expenses, directly or indirectly aris- ing from the sale, handling or use of 1he equipment, or from any other cause relating thereco, and EC's liability htreunder in any case is expressly limited to the replacement (in the form originally shipped) of equipment or any part thereof, not complying with this order, or, ac EC's election, ro the repayment of. or crediting buyer with an amount equal to the purchase price of such equipment, whether such cw.ims are for breach or warranty or negligence. THIS WARRANTY IS EXPRESSLY MADE IN LlEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCI-lANT ABILITY AND FITNESS 4. Liability EC shall not be liable for any losses, damages, or delays due to or caused by transportation difficulties, fire, labor shortage, strike or other labor disputes, civil or militalj' authority, insurrection, riot, war, accident, shor- tage of labor or material, flood, ston:n, flotation of equipment, or any other cause or circumstance, whether like or unlike the foregoing, beyond EC's reasonable control or for any delays due to failure of Buyer to furnish and/or approve technical data, drawings, etc. Acceptallce of equipment on delivery shall constitute a waiver of any claims for losses or damages due to delay, whether or not excused by the foregoing, and a waiver of the right to revo.ke such acceptance for any reason. Further, under no circumstances shall EC be Uable for any li- quidated, special or consequential damages or for any penalties, whether direct or indirect. 5. Indemnity The Buyer expressly assumes and agrees to indemnity, defend and hold EC hannless from all liabilit.ies. claims, demands and actions made by any person, firm or corporation, including employees, workmen, ser- vants or agents of the Buyer and his subcontractors that may have been caused, or allectged to have been caus- ed, directly or indirectly, by any act of omission or commission, negligent or otherwise, of the Buyer, its sub- contractors, their employees, workmen, servants or agents, or of EC, its employees, workmen, servants or agents, or by reason of the premises. EC's equipment shall be: considered as being under the sole custody and control of the Buyer during the period of its use by Buyer, and should any person or persons in the employ of EC be used to operate said equipment during the period of such use, such persons shall be deemed during such period of oper.i.tion to be an employee or employees of Buyer. 6. Design If working drawings are furnished by Buyer, EC may change details to conform to EC's standards of fabrica- tion and conscniction. With respect to any enor or deficiency in any provision of the specifications, plans or drawings furnished by Buyer, or any of its agents, Buyer shall indemnify and hold EC ham1less against any or all clairns or losses , as~erted against or sustained by EC as a consequence of any such en-or or deficiency. In on:ler to use ava.ilable sections of material, EC may substitute equivalent sections of material and vary plate 02/19/1 99 9 12:15 7043752439 ESHELMAN CAROLINAS F'AGE 05 FA"GE 2 C,p1 widths and lengths from those stated in EC's proposal or applicable specifications and drawings. EC reserves the right to make changes in its design, construction or arrangement of equipment at its plant, or at reasonable times at the place of installation, as in its sole judgement shall constit\Hc an improvement over fom1er practice or otherwise benefit Buyer. 7. Changes or Delays .If at any time the Buyer delays or interrupts the progress of the work, or causes changes to be made, or if there is a lack of facilities or apparatus to be supplied by the Buyer, then the Buyer shall rt;imburse EC for any adl1i- tlonal expenses resulting from such causes. The Buyer agrees to pay EC for any extras in the fonn of labor and/or material to cover such e:1:.tra work as may be incurred over and above the work necessary to execute nom1ally this order. If Buyer refuses to accept shipment of equipment on the changed shipment date, EC reserves the right to assess Buyer at the rate of two per cent (2 % ) per month a handling charge beginning two (2) weeks from said schedul- ed shipment date until the date of actual shipment of the equipment to Buyer. This charge shall be in addition to any !ale payment charge EC may assess. 8. Title Del iveiy of goods by EC to common earner or trucker shall be deemed delivery to Buyer, and thereupon title to such goods and the risk of loss or damage in transit shall be Buyer·s. Any claim by Buyer against EC for shor" tage or damage occuring prior to such delivery shall be made in writing five (5) days after receipt of shipment and accompanied by the original transportation bill signed by the carrier noting that the carrier received the equipmem from EC in the condition claimed. 9. Cancellation Equipment cannot be rctumed and this order once approved cannot be cancelled, without EC's prior written consent , In case of cancellation, Buyer agrees to reimburse EC for all costs incurred plus a margin of 20 % . EC reserves the right to cancel any order without further obligation thereunder and without notice to Buyer in the eve.nt that EC's submittal drawings, if required, are not returned ro EC within sixty (60) days after receipt by Buyer with approval noted or with appropriate notations for correction. 10. Del.Ivery to Site Delivery by trucker or common carrier will be made to nearest points reasonably accessible by same as deter• mined by the driver. Buyer will fumish and pay for necessary labor to unload and to store the goods. For EC's information only, Buyer shall note loss or damage in shipment upon delivery ticket returned to EC. 11. Modincation No condition. representation, or agreement altering, detracting from, or adding to the provisions of this order shall be valid unless condition, representation, or agreement is in writing and approved by the Buyer and by an authorized representative of EC. 12 . OSHA and other Codes To the best of EC's knowledge and belief, equipment furnished by EC conforms with all applicable Occupa- tional Safety and Health Standards promulgated punuant to the Occupational Safety and Health Act of I 970 and set forth in T itle 29, Code of Federal Regulations, Part 1910 (29 CFR 1910) at the ~ime of design. Due to the probability of differing interpretations of the Occupational Safety and Health Standards between the Department of Labor and EC, EC makes no warranty that its equipment conforms to the requirements of the Occupational Safety and Health Act as may be interpreted and applied by the Occupational Safety and Health Administration, Department of Labor. Should Buyer Require compliance with any particular state or local code, Buyer must request the same of EC in writing enclosing a copy of the specific code involved. Upon the receipt of the said code, EC will offer its in- terpretation to meet that code. However, EC makes no warranty that its equipment will conform with the re- quirements of the state or local code in question as said code may be interpreted and appUed by enforcement personnel in the field . 13. General A . In the event of conflict between the generaJ terms and conditions statM herein and the tenns and conditions stated in the plans and specifications now or hereafter existing, or the terms and provisions of Buyers pur• chase orlicr. these gener-aJ terms and conditions shall govern. Buyer's signed acceptance of EC's proposal, purchase order or any other expression of acce.ptance shall be deemed to be a written confirmation and acceptance of these genera.I tenns and conditions. Further, accep• ta11ce of this order is expressly limited to its provisions and these generaJ terms and conditions. Conduct or _i:."1erfom1ance by EC regarding the existence of a contract shaJI not constitute an acceptance of or assent to any addi!ionaJ or different terms or provisions proposed by Buyer. B. The validity, construction, and effect of this order and of these general tenns and conditions shall be govern- ed by the laws of the State of N. C . C . As used herein the term "EC" means "Eshelman Carolinas, Charlotte, N. C .", and the tenn "Buyer" means the person or entity for whom che work in this order will be done. · D. Waiver by EC of any breach of these terms and conditions shall not be construed as a waiver of any ofoer breach, and failure to exercise any right arising from any default hereunder shall not be deemed a waiver of such right which may be exercised at any subsequent time. · ,,,.,,.,, ......... ......... ......... :r :::c :::c ill.,,.,, 000 11100 -N -N~ ~~~ ---NNN NNN (!_.ti 'I· ITT?.... <9F- i-AtJ D F I L.L /V35b' Len 3+h of-f ,~ = def#.. :c Si'/1 G>- 35D 1 -3~0/ ~ 30 I --=-3_0 __ -:--_ 5y,, (33.3°) L 1:; A c· Id-~ fi4rr 133 -{)t, 9',Z X :3$1-~ 11/ € Ll.5 -/y__D/lTI-I-1 Sau Tl-/ -PulY)PED -.;z.o -2S 3/!<_f iv d r_<;f ID KEGJ.!M:fE -/o -1 :z_ A y- /f;r ~~ti ~c. ;;. 3o 1-/ /J t/4&1 hz · /tvf 1111e.- !Za {t'Jh I /J/'{ i-;.i-911'/ .-;;; ""7 t? 5 Ac. 0-,q vJ J:nc-. I;;. 3c; 1/f/.t:k er Or-. /\afe(Jh 1 ;,/ l q33 ,>'5"fi 5feve.- ~/Ate {;,l'vJr,'r~~()t &. 3~() /.:,Je uJa/4~ /J~ tk3/2 ~N'L :}/2 -3'11( ?.Oscrn,,, @ /00____, &--~4.-1l ..,.._.,,_,, 3/8' 0.D. TUBE CONNECTOR 1.25' O.D. TUBE CONNECTOR S4X <FOR 4' \./ELL CASING) S6X <FOR 6' \./ELL CP,SING) S8X <FOR 8' \./ELL CASING) PARTS SHIPPED LOOSE \.//PUMP C30/8' O.D. TUBE~ NNECTOR EXHAUST ~ DEFLECT□; ~ CLAMP _____.flJ (£) {l) 3/8' 0.D. TUBE CLAMP ___-ffi (iJ (iJ 1/2' O.D.TUBE i:t:-:.~@@ I INSTALLATION INSTRUCTIONS 1. 1 1/4" DISCH?>.RGE TUBE SLIDES THROUGH 1 1/4" CONNECTOR 3/8' AW SUPPLY TUBE SLIDES THROUGH 3/8' CONNECTOR. TIGHTEN ALL CONNECTORS CUT EXHAUST LINES OFF TO REQUIRED LENGTH UNDER THE CAP. SLIDE C,'.\P OVER \./ELL CASING, 2. ST ANDA~)D \./ATERLEVEL METERS PROBE MAY BE USED. REMOVE PLASTIC PLUG IN 1/2' NPT HOLE AND INSERT PROBE. 3. · TO INST1\LL VENT DEFLECTOR TO THE VENT TUBE UNDER THE CAP. PUSH INTO 3/8' O.D. TUBE. CRIMP Ci_AMP FOR 3/8' O.D, TUBING AROUND TUBE. 4. TO CONN1~CT AIR SUPPLY, INST ALL TUBING CONNECTOR TO PUMP AIR SUPPLY. 5. EXTRA TUBING CLAMPS ARE SUPPLIED FOR TUBING. ATTACH TO PUMP OR OTHER TUBING/BARB CONNECTIONS. 6, IF FILTER REGULATOR IS PURCHASED FOLL□\./ THE INSTRUCTION SHEET THAT IS SUPPLIED \./ITH REGULATOR ON HO\./ TO INST ALL. 95094 REV, A ,,,.,,.,, ......... "'"'"' "'"'"' :c :c :c .,,.,,.,, 000 11'100 -N ;- W ed (\ ·~ -?! .(. § a J i i' \ ..J ' .,( J "" 1 .... )I \i) -2:i &' J ). 1.u c:: L.!) 0 ~ ~ ~ 3 ~- -:l. ! -"' 4'.. J i tj i 'l ::;:, ~ "'-::: ~ ::i j ~ I-t:\ .\) IJ 0 <>'.:. ... r: -<D 4 I-~ ~~ 1 VI ~ ~ ~ ~ <l: e ~ C l3~ <::,.. f '.) Q.. -i \ ~ :.J %1 '.:) v'l r rB.18.1999 2=50PM QED ENVIRONMENTAL SYSTEMS N0 .755 F'. 1 TQED ENVIRONMENTAL SYSTEMS, INC. FAX COVER SHEET DATE : February 18, 1999 Mr. Ed Mussier TIME: 1 :51 PM TO: PHONE: 919n33-0692 NC Div. Of Waste Mgt. FAX: FROM: Brian J. Root PHONE: FAX: RE: QED Estimate # R0299-24399 Number of pages including cover sheet: ~ Dear Ed: 919/733-4810 (800} 624-2026 (734) 995-1170 Please find attached the system proposal for the SL6000 Slider Pump system that we discussed. This quotation included everything you will need for a complete leachate removal system for slanted or horizontal wells. I have also checked out inventory and all of the items are in stock and ready for immediate shipment. Please also find attached the latest sales and technical information on this equipment. If you have any questions, or require furl.her information, please call me at (800) 624- 2026. I look forward to hearing from you. Sincerely, 7-z". 0 . 7~ Brian .f. Root Inside Sales Representative E-Mail: broot@qedcmv.com Website. http://www.qruienv.com cc: Steve Tobin (Eshelman Carolinas) F~S. 18.1999 2: 50PM QED ENVIRONMEtffAL SYSTEMS N0 .755 P.2 ~QED ENVIRONMENTAL SYS7BfS, INC. ESTIMATE# R0299-24399 P 0. Box 3726 Ann Arbor, Ml 48106 Phone: l-800-624.2026 Fax: 1-734.995-1 170 February 18, 1999 To: Ed Mussier ~orth Carolina Division of Waste :Management 401 Oberlin Rd. Raleigh, NC 27605 Phone: 919-733-0692 Fax: 919-733-4810 Your QED Rep : Steve Tobin Eshelman Carolinas Inc. Phone: 704-376-6408 Fax: 704-376-2439 Prepared by: Brian Root Product Description ( em Number Unit Price Extended Prjce 1) I EA 2) EA 3) EA 4) EA 5) 100 FT 6) 100 FT 7} 100 EA Slider Landfill Pump. All pneumatic, designed for sloped well risers. Materials: Stainless steel, Teflon, Viton, Delrin. Maxmrum flow 9.5 GPM. Pump length 69", 4.5" O.D. Includes cable attachment hardware. SL6000 ------------------------------------2,995.00 Typically used in coDjunction with High Capacity or Alpha-style Ferret In-Well Separators. Controller can be powered by runlight or 110 volt power outlet. Intrinsically safe in solar powered mode. Compact size and environmentally sealed cue make it suitable for outdoor remote use. Solar banery provides 10 clays of reserve power. This controller will i.nc/ude a 2SOA valve for high capacity operation. C100 ------------------------------------950.00 Pulse Pump Custom Product Special 6 '' PVC Slip fit well cap. Supports Slider pump 1114 '' Liquid discharge and 5/8'' air suppZv lines. Also includes S.S. eyeboltfor the auachmenr of braided srainless steel support cable PP-CUSTOM _______________________________ _ Pulse Pump Custom Product Special Teflon-coated Slider Pump E.wusr Valve. Compatible with 5/8" air supply line. PP-CUSTOM ______________________________ .. _ 1-1 /4" O.D. nylon discharge tubing . 37014 ------------------------------------- 5/8~ Nylon Tubing. 37681 ------------------------------------ Stainless steel cable, 3/16". t:"sed with 4" Hammerhead pumps and required for pump depths greater than 100 feet. 37060 ------------------------------------ 110.00 125.00 4.85 1.85 1.70 E-mail: info@qedenv.com QED website: http:/ /'WWW . qedenv . com 2,995.00 950.00 11000 125.00 485.00 18 5.00 170.00 Pagel F~B.18.1999 2:51PM QED ENVIRONMENTAL SYSTEMS N0 .755 SYSTEMS, INC. ESTL'\U TE # R0299-24399 P.O. Bo,: 3726 Ann Arbor, MI 48106 Phone: l-80<Hi24-2026 Fax: 1-734-995-1170 To: Ed Mussier North Carolina Division of Waste Management 401 Oberlin Rd . Raleigh, KC 27605 Phone: 919-i33-0692 Fax: 919-733-4810 Your QED Rep: Steve Tobin Eshelman Carolinas Inc. Phone: 704-376-6408 Fax: 704-376-24.39 Prepared by: Brian Root It~m Qt! Cnit Product Dei;gjption / Part Number Uuit ,erice Extended Price .ESTIMATE TOT AL OPTIONAL Jit\-JC~> 5,020.00 8) 1 EA Level Mate, liquid level control module with eauge. Used in combination with one Pulse Sender. L375 -------------------------------------855.00 9) 100 FT Gasoline resistant, L-V protected, black nylon tubing, l/4P OD. 3~15 ___________________________________ _ 0.85 Terms & Condirloru: Estimated Shipping Time 1-2 weeks after receipt of Purchase Order. Final delivery date will be detl!rmined at time of order. All prices are in U.S. dollars, FOB Ann .Arbor, MI, USA. A copy of your purchase order is required ar n·me of order. "Pricing and Delivery on all specials will be determined after rec~ipt of order." Payment terms are Ner JO days with approved credit. Total price DOES NOT include applicable sales tax or freight. A servic:e charge of J.S% per month will be applied IQ all pa.st due invoices. Pricing valid for 30 days. After seller accepts, NO order may be canceled withaut Seller's written consent. Cancellarion, if approved, is subject to reasonable re.stocking and/or handling fee. All produc-rs ·will be returned freight prepaid to Seller's facility. Accepttd by: ______________ Title: PrimName: ______________ Company:-------------- PO Number: ______________ Dare. _____________ _ {Hard copy of PO required before shipment} E-mail: info®qedenv. com QED website: http://www . qedenv. com 855.00 85 .00 Page 2 FEB .18.1999 2:51PM QED ENVIRONMENTAL SYST~MS N0.755 P.4 TOUGH PUMPS™ Slider™ Pumps for Slant/Horizontal Wells t A new angle on leacha.te, condensate, and cleanup pumping. The increased availability of spe- cial drilling equipment has caused more landfills and cleanup projects to appreciate the unique advantages of low-angle (slanted or horizontal) wells or risers where conventional vertical wells are inef- ficient or impossible to use. Sloped landfill risers for leachate and/or landfill gas allow wellhead installations and other equipment to be placed outside landfill cells, not in the middle of them This protects headers and other equipment a.rid facilitates normal la..'idfil! operations. Cleanup projects can also benefit. Karrow water or product layers can often be more efficiently intercepted by a horizontal well. Inaccessible contaminant plumes under buildings or sensitive areas can be reached; the technique is also a cost-cutting alter- native to trenches for capturing wide- spread floating layer,. Howe\·er, slant/homontal wells are useless without the right pumps - and typical electric submersible or pneumatic pumps don't operate effec- tively in low-angle or horizontal installations. QED Slider™ pumps provide the answer. They have proprietary angle- independent valves to operate at any orientation, and can deliver reliable flow at rates up to 9.5 GPM/13,680 GPD in 5" and larger wells. They can also be modified to fit 4" wells. They are especially suited for tough landfill duty, providing excellent resistance to sediment clogging md solYent attack. Slider pumps are .operated by QED' s standard Pulse LinkO Controller Modules. I SLIDER SPECIFICATIONS Model Pump Type 0 .0 . Length Weight Materials Fittings Discharge Air Supply Sizes Discharge Air Sueely Pump Stroke Operating Pressure Range Maximum lif'I Maximum Flow Rate Cap Sizes 18 SL6000 Angle-independent positive air displacement 4.5" (11 .4 cm) 69" (175 em) 30 lbs. (13.6 kg) Stainle~ steel HOPE Teflon. Delrin Vlton Stainless steel barb type Stainless steel compression 1 1/4" (32 mm) O.D. tubing 5/8" (16mm) 0 .0. tubing 1.s gallons (5 flte1o) maximum 0 -100 psi (0 • 700 kPa) 200 feet (62 meters) 9.5 GF'M/36 L.PM (1316S0 GPD/51 1600 L.F'D) 4" (150 mm) and up Slider Pump Advantages • Flow rates ro I J.680 GPD at any .ingle 11: :,lr:,pcd or hori..:011- t..1.I wclb and I t'.>ers • Ea:.y m:.1.1ll.1c1on --srnood1, rounded t>nd caps slide pasl cur·vcs an~1 c.1:,rng obsrrucrrons. • Renea! pro5r·a111 3vailable. : ACCESSORIES MODEL 9999• 9999• 37681 37014 3706Dt DESCRIPTION WeDC8p Exhaust Valve SJ8" (16 mm) 0 .0. Nylol"I Air Supply Tubing 1 1/4' (32mm) O.D. Nylon OiSCharge Tubing Cable -3116" (5 mm) Sta.ll"!less Steel ·Contat:t oeo to dQtsrmine correct size for your system. t Nole; Slidet pump Includes Sling Assembly for cable llttachment. See Elimi'WOr Ac:cassories on page 17, or consult OED fer control equip• ment. ,.o ! :i.o 0 0 20 0 g SLIDOO Pl.OW CIJfM - "4l 110 ,2 18 "UUI' or.,,n; (IDct) "UMP Otr.'",..( (mellsT.\ 60 100 2◄ 30 TGiD Environment.al Systems, Inc. .. . P~B.18.1999 2: 51PM QED ENVIRONMENTAL SYSTEMS N0.755 P.5 TOUGH PUMPS™ Modular Pneumatic Controllers L600 L3S4 L360 (top), L380 (bOttom left). Integrated external control systems are engineered for flexible application, reliability, and trouble-free performance. r'"f"he Pulse Link,: modufar control 1. system operates all Seeker", Sliderr--', Eliminator, and Pl.llse Pum~ models, with options to serve multi- ple well and level c;ontrol needs. QED pneumatic control modules are the design forefront in reliability and longevity. We set our 0.-.11 high stan- dards for material$ and design, unavailable from typical industrial suppliers. Basic control Every QED c;ontroller-driven pneu- matic pump system requires at least one Pulse Sender4 module. The heart of the system, the PuL~ Sender unit continuously generates air pressure/exhaust cycles. Pressure regulator, output pressure gage, and refill/ discharge timers allow easy flow rate opt:im.i.zing. One Pulse Sender module can run one pump. or two pumps close together. With accessory Well :Master TM and Remote Well Operator units, a Pulse Sender unit can cvcle up to six pumps as far as 200 fe'et away. (Note: nmning pumps in mul- tiple remote wells, maximum pump flow rates mav be reduced; consult QED for specific guidelines.) 22 Level control (singfe well) The L!,•el Mate™ controller turns the Pulse Sender cycles on and off automatically, responding l'O changes in water level in the well or product lev~ in floating layer inlets. Level is measured via a bubbler tube placed just below the desired liq- uid level in the well or inlet. The pres- sure needed to expel bubbles indicates height of liquid above the end of the tube ($1.lbmergence). The gage on the I.375 InOdel displays the submergence in inches. One Level Mate unit can provide on/ off control for up to six pumps, with all puinps responding to level changes in the d\osen well Level control (multiple wells) Well Master?M controllers are used with a Pulse Se:nder module in multi- ple well systems, where independent on/ off level control is r~ for more than one well. Each Well Master unit controls one pump, and has its own bubbler tube to sense liquid level fluctuations in that well Th.is makes it possible to "fine-tune" pumping efficiency in sys- ~ with wells that differ significant- ly in recovery rate. Economical multi-well control Remote Well Operators are used with a Pulse Send.er unit (with or with- out a Level Mate controller) to operate pwnps at each well in multiple-well systems. Remotes can also be used in mixed systems for conti.nuous pump- ing of some wells, with Well Master on/ off level control for others. Models for 2" and larger wells are available; the 2" version has the pump exhaust attached. for use above the wellhead when there is no room inside the casing for in-line exhaust valves. QED Controller Advantages • Modular :.yscc1n provides cus- lomized control for eve1-y !:.tte • Engmee, ed for 1el1abdicy wn:h ··poppet" style air valves. cwo- sc:ige air filters. and imported high-p, eci:.ion c1mc1·s. • Renl.11 p1·ogram available. 'YGS:> Environmental Systems, Inc. ( I &. _. ::) 9 .. ·FE'B.18.1999 2:52PM QED ENVIRONMENTAL SYSTEMS I CONTROLLER SPECIFl~ATIONS PULSE SENDER LEVEL MATE Model No. l.360 L.370 L37Sw/Gage 1.3n Referenced Dimensions See M0Unti,,g Clmanslons See Mounting Otmens!ons (below) (below) Weight 6 lbs. (2.7 kg) 4 lbs. (i .8 kg) Operating ~rHsure 40-100 psi (275-700 kPa) 40-100 psi (27~700 kPa) Max. Free Air Aow 7 SCFM (12 m~/h) Not Applicable Features Provtdll& altamating, timed Multi-well level control. pres&Ure, and extiaust Corrosion retisiant level cycles. Reliat:lle "r)cppe!" sensor valve; efficient timtl'$ and air powar valv• external orffictmlter module; ing: high-aceuracy, low-s-e-(7.5-15 cm) or'Voff drift. 380 degree pneumatic range; L3?5 only-0-1 oo• timers; locking regulator water level gage, Olher ring; o,,cle coun1er tap for ranges availat:lle. L377-raf• easy counter installation; eranced control fer wells high flow air valve. undar pressure or vacuum. WELL MASTER REMOTE W!U. OPl,.ATOR ModelN0. L380 L600 Dimensions See Mounting Dimensions 5• (12.7 em) 1-1 X (below) 5" (12.7 cm) W X 3· (7.e cm) o Weight 5.5 lbs. (2.5 kg) 1 lb. (0.5 kg) Operating Pressure 40-100 psi (275-700 kPa) 40-100 psi (275-700 ~) Max. Free Air Flow 7 SCFM (12 m'/h) 7 SCFM (12 m'/h) Features Sl11gle-wefl level control. Compact size; high flow air Reliable~ style air valve. power valving; O!'lloff ll'ldl• cator; higl'I flow a.Ir valve; high effieiency, extemal orl• fioelfilter module; 3-6" (7.~ 15 cm) on/off range; COITO· slor, resistant plastic level sensor vatve. CONTROLLER ACCESSORIES MOCEL DESCRIPTION 35694 Environmerl'.al Enelo$1Jre L390 L395 35761 35410 35527 35528 t3.2S"x15.3S''x7.75' (33.7 x 38.1 x 18.7 cm); holds 2 modular control units Air Filtration pkg. 12 SCFM (20 m'11'1), for 1 -3 Pu:np Systems Air Filtration Pkg. 35 SCFM (60 m'/h), for 4-10 Pump Systems Replacement Filter Element PneUTT1a:ic Court.er 05' (13 rr.m) Quick-ccnnec: o.s-(13 mm) Quick-connect 90' elbow Simple refinements can mal<e a big difference Humidity corrosion by-products or oil in the air supply used to cause problems with on/off level controllers. So we redesigned the air filtration system, putting a glass fiber pre-filter and a microp- orous bronze element in a trans- parent nylon capsule on the out-I side of the control module. It's 'I easy to inspect (and replaces in seconds, if necessary). Since the 1 redesign, level control malfunc- tions have dropped to near .zero. Tough Pumps TM Cacuog AIR REQUIREMENTS For best results with all controllers, dean, dry air suPl)ly at 100 p.1 (?00 kPa) Is 1'9quirad: 10 micron filtration, <1 0PPM oa, clew l)Olnt 20°F (11 'CJ below minimum operating temperature. Maximum total system c!iecharge head Is 2.30 feet (70 meters) of water. See l)ages 24-25 for air compressor information. System diagrams for easy specification and installation QED has num~us diagrams, schematics, and drawings covering nearly every configuration of pumps, controllers, and wells, !Tom basic single-well installations to the most complex multi-pump, multi-well systems. These draw~ ings help understand pneumatic logic, tubing connections, and pump optimization. Your QED applications sptcialist will be glad to supply you with diagrams for your project. N0.755 P.6 SEEKER MATE l.376 See Mountlr,g Dimensions (below) 4 lbs. (1.B kg) 40-100 psi (275-7001<F>a) 7 SCFM (12 m'/h) Depth/pressure gage stm- plH!as Seeker pump instal- lation; Hlg" level shutoff air connection prevents l)IJmp frcm operating if wen level rises out of range. REMOTE WILL OPERATOR L.354 s· (12.7 cm) H x s· (12.7 cm) w x 1 lb. (O.S kg) 40-100 psi (275-700 kPa) 7 SCFM (12 m'/h) Compact size; high flow air valve; Tenon c:cated exhaust valve. MOUNTING DIMENSIONS L360, L370, L376, L376,L377,L380 Module, Note: MOdules ~vlre 5evaral lnchQs clsarance above, below, and at sides for hose:a, filters, and other exterior fittings. II ~4 cm) l .7emJ 23 ,, $.&;~~~iu, . .;. .. :;~ ::::::::::=:•:=:=:•:=:=:•:••·•·= ~~··11··-at·rfrl<w~a<a~xs.: -==·=·=·=·== · ·•==== I :=t=::::t ?WWitfil..%.WI®l:fflll§l -PCB LANDFILL INVESTIGATION Warren County, North Carolina P. M. Backus North Carolina Department of Environment and Natural Resources Division of Waste Management NCDENR -EPA Region IV February 16, 1999 ►, Land£ ill Questions tfiMF?',t\,:,tt=rr:r?t:=:=?:< ,:,m:,;mmmttmmm\'i :::::::::::::::::::::: '8888l8883li'8PMru:tnm e Basic Questions » Is additional water getting into the landfill? » Where is the water in the landfill going? e Investigation Questions » What are hydraulic parameters of the landfill? » What is causing the fluctuations in water level? » How much water can be removed? » How can we improve water removal? NCDENR -EPA Region IV February 16, 1999 1 Land£ ill Investigation Additions to Site in 1997 i1rnrrw@t.f.ITT@t:'ff.f.ttrnrnr:r:rrr=r ,t,Ittt It ,:}',:,=n=:,,,t::::::::::mim:r.@mm e New Wells » Seven wells added outside of landfill » Two wells added inside landfill • Weather/Water Level Monitoring » Station added to monitor temperature, barometric pressure and rainfall » Piezometer added to monitor water levels in landfill » Data logger added to record data on hourly basis NCDENR -EPA Region IV February 16, 1999 .:2.. "-I ----~ ---~ ~---------______ _........--.-'\_ /\:\ / \ __ I ~ MW10s/d MW9 -~ MW2 0 !) ', --~ //, i( ft MWI~ ·.\\X~ :111 : i1t~~\ "~'1;\, 0 ~ \ M·f~s/d 1 \I MW7s/d ~ MW•ls/d ~ ~ f.<!Wtl ~'~ '.l1Nl ~ MW6 ~ / ___ ..,-(J \'---._) \-~~-j / ~ MONITORING WELL ~ NESTED MONITORING WELLS 0 l 2':0 · 00 SCALE 1" = 500' WARREN COUNTY PCB LANDFILL 1000 NORTH CAROLINA DEPARTMENT OF ENV!f>ONMENT AND NATURAL RESOURCES DIVISION OF WASTE MANAGEMENT FIGURE 1 (v Landfill Hydraulic Conductivity m@lm;..,, ...... ., ......... ::::::··-...·.····· ••••· •····· ..... , .,, •• ,.· ; ••••• ; •• ·" ..... ;~;;;;;~;:~: ;;~;:~' ·.·•····•.····::::: .. J.'..:.'.Jil%® fji8gi'81 ?S88S:dlffill81 !8ii8 r e Slug tests were conducted to determine hydraulic conductivity of soil in landfill >> Initial data indicated K ~ 10-4 cm/s >> Review of initial results and new slug tests indicated K ~ 1 o-8 cm/s e Hydraulic conductivity is consistent with what would be expected for materials in landfill NCDENR -EPA Region IV February 16, 1999 4- 0 :I: -:I: Slug Out South ,lV,ell 1 •········ ··-·•···-. ······· -·· ··············· ··········•· ·············--·······"•········· !------·-·-k= _ _r21n(L,e/R) 2LeTo Where: r = 0.52 ft R = 0.52 ft Le= 12.50 ft To= 19,200 s k = 1. 79 x 10-6 ft/s or 5.5 x 1 O..s cm/s 0.1 -1---------4------------------+----+------+---·------+-----------------1 0 100 Warren County PCB Landfill 200 T0 approx. 320 m~tes I 400 Time (min) North Carolina Department of Environmerit and Natural Resources Division of Waste Management 500 600 700 FIGURE?@ 0 :c -:::c: Slug Out North Well 1 ~··· ·······-··•··•········ ········-····---····· I~~. ~. ,..________ . ----------k= t!DL'=J..fil 2LeTo . ' . '-------..__ -----♦ ::-,, Where: • • ~----------r = O. 52 ft • R = 0.52 ft •'-------.,, Le= 14.20 ft •-------...__i...__ To=2,100s ~~ k = 1 .49 X 10-5 ft/s --..___•~~------------'----.: • • or ,, . '-----------....__ ♦ ♦ 4.5 X 10"8 cm/s ----------. ------------------------"~ -------------------------------0.1 0 I ~~ala~ a a~a a~ ~ N ~ ~ ~ m ~ ro m o Warren County PCB Landfill T0 approx. 35 minutes Time (min) North Carolina Department of Environment and Natural Resources Division of Waste Management ~ FIGURE6@ l ~ SLUG OUT NORTH WELL REEVALUATION OF PREVIOUS DATA -I -c~ ,.., -7 ~ V '· ,g ~--, f< ~ 3.1 ,Y /0 P,1/2-_____ _ ••• .... ,£ :i: f----· •• .. ._ • _. ♦ • ... • • • ♦ • • • 0.1 +------·-+------+------....-------+------+------+------+-------+--0 10 20 Warren County PCB Landfill 30 40 50 00 Time(min) North Carolina Department of Environment and Natural Resources Division of Waste Management 70 80 90 Figure 8 (y Fluctuations in Water Level Millllii:❖:•.·:.:.:.:.:.:.:::·:·:·:·:·:·:·=·:·=·=•z•:•:;:::;:;:;:;:;::;;;m~:;~;;;;~;:L,,,, ....•.... : .. •. :=: .... :,:;.;.; JS'l>PW:: WC&®: e Comparison of raw data indicates a relationship between barometric pressure and water level but no relationship between rainfall and water level e Regression analysis indicates relationship is negative and linear (r2 = 0.93) NCDENR -EPA Region IV February 16, 1999 :,::::=::::::::::::::::::::,J?'?H:H\:H:mmllli rr ;r; 7 n 8 0.9 0.8 0.7 0.6 ]: ~ 0.5 C: ·;;; 0:: 0.4 0.3 0.2 Rainfall and Water Levels September 7, 1998 3:01 am to January 28, 1999 11 :01 am T 344 T 343 L~1VL, t 341 I iii I E E. 340 -~ C1) • .J ... C1) ·; 3: 339 I I t~ l 337 0.1 ' I /',, j\ ,~ r 111/i ""f1 ; (\ / , l \~ 1 )\f\A }.N'fi'~~ . ;111-/.f\~ . _ / "¼,,, ril'r1 _ 11N rV1 1, !~ . 1111" \_ J flJ \j'\ i✓ vi ,vi Nvvw .fl,, ' '". \ti) u1r----.,., "v ' vvv-, I u ~ 'v, '11v, • '"if' f '1'1 ff I i . V' • 111 . . ~. ,. .. " , ,,,_,_,. 0U1,1l1,~,tt11-11-r+11•L•~.1~,.-,~,J,u~•,~.L~1~,~~~1~1•~~~r+1-r~.~-~.~-~-~-·~.H-H~+-r--llL4+~-t-H++-1-r~ri-,-r~~, \11f'"\1fl\ 1i . l: 336 Warren County PCB Landfill Julian Date r·-· ~_r~_i_n --nortt, -::-_~outh_) North Carolina Department of Environment and Natural Resources Division of Waste Management FIGURE 5 (j) 30.2 -I 30 T oi 29.8 t :c ! :§. <1l :i Ill Ill I i!! 29.6 Cl. u ·;: 1 I m I Ill I 29.4.,. ! I 29.2 -I I Barometric Pressure and Water Level North Well September 7, 1998 3:01 am to January 28, 1999 11:01 am T 343.2 I I f 343 I 1342.8 iii E :E.. C: 0 342.6 ~ ~ I H3424 j 3422 > <1l ijj ai iii :i: 29 J-t-r ---t--;--+-,-t-+, +-l-++H+-+-t ·--+H-:-r-++----r-1-+-t ,-,.-r+-+-t· t---++++--b+--~r--·+++r+-t-+-+-t-++-r--++++-+-t-+-t-+-t-t-,-·---,--,--1-t-+-t-+-++t +r-t--r+++ ,·-+-t-r -t -i-j--,-j --t-+ ·!+·· +-+~ t --t-++ ++++-t+-t-H-1-+ -I +-t+-t-/ j L, Warren County PCB Landfill Hourly Readings Each tick mark denotes 24 hours [_ -· bp --north ] North Carolina Department of E.nvironment and Natural Resources Division of Waste Management FIGURE 2 (ii) C) Xl.2 j I 3J l i ' 29.8 -I 29.6 i ~ I ,5 l ;-29.4 ., :5 (I) i I u ~ 29.2 T E I e '. "' ' a:i I 291 ! ~· t Barometric Pressure and Water Level South Well September 7, 1998 3:01 am to January 28, 1999 11:01 am I I, ~ ( Ill /' ii 11 ' '. I -I 1 r 111 !\ ~ .. 1 \ ~ ! I I I I\ l 11 I I~ I I I ~ ·_ • ,l ·_ I I LJ j I ~ ' I I ~ II ,I ' ' \ l \I 1337.6 ' 337.4 1337.2 r 33, I ' 11 i336J 1 1 11 1 : 1 1r ~ 11 ~ 1 I I i~ J I !, ~ i ~, ~, r f , I t 336.4 11 ; I f 336.2 28.6 f ' i ~ 4 L•-h-a---,-+ ,-,-~--r'+++++<+H+H~• ++ ++++·--+++-H++-•-n++tt , 1 , , , , · .. ~-,_ .. e+,-H ;--tt-+--<+H-•-½+H+<-H-<4+•-H~-H--ttH--H+H-J 336 Warren County PCB Landfill Hourly Readings Each lick mark denotes 24 hours r-· ---7 1--bp --south North Carolina Department of Environment and Natural Resources Division of Waste Management FIGURE 3 (jj) 146.1 ~······ .. ---····-146 145.9 iii !:. .J w > ~ 145.8 ~ w ~ ; 145.7 145.6 BAROMETRIC PRESSURE VS WATER LEVEL • -• • . , • ... . .. * • •• • y = -1.0524x + 161. R2 =0.9313 145.5 +---------+--------+----------+--------+----------+---------! 14.2 14.3 Warren County PCB Landfill 14.4 145 BAROMETRIC PRESSURE (PSI) 14.6 14.7 North Carolina Department of Environment and Natural Resources Division of Waste Management 14.8 , -SOUTH ~Linear (~':)UTH_l FIGURE 4 @ Estimated Volume of Water in Landfill mimir••;;;••-;;••••••w•••W•••••••••:••• ••••• ·:~rurun,,M=:,;:;:;:;:;:; ,::;:•;:;:;:: .. ;.;.;.;.'::::-•••• • ;;;:;;;:;;;;.;:;:;:;:; :::::::::::::::::::::::=? : ::::::::: }::: }}}::}:: : ::::}:}t•• ::::=;=mwr.fl'll'ill® e Average moisture content of samples from new wells inside landfill was ~13°/o by weight, ~25°/o by volume e Total water (bound and free)= 2 M gals e Theoretical amount of water that gravity will drain from landfill soils = 3-7°/o by volume= 60,000-140,000 gallons NCDENR -EPA Region IV February 16, 1999 13 Leachate RemovalProblems mmmt.:.J •... :.-.. : .. :,:,:,:,:,:,:,:,,,,·····.·. r :::::::::::::::::::::;::;;.::::;;;;;;;;;;'= :::::=t::mmwmmmm JS&Zni'8n • Original sump is probably undersized for current operation. Recharge of sump begins immediately after pumping but takes -6 hours to reach previous level. Estimate is 0.3 gpm. • Draw down tests at new wells inside landfill indicate even lower recharge rate of 0.04 gpm. • At these rates it would take 9-11 months to remove estimated water that will drain from landfill. • Leachate treatment system is probably due for improvements even though no PCBs have been detected. Sand and carbon should be replaced. Sprinkler system needs to be operational. Should holding tanks be added to allow batch treatment? NCDENR -EPA Region IV February 16, 1999 J'f ~-:-.J~± •. :: ... ,.,.:::::..:::::;::·::·······.·-·-·.·.·.-.-.-.;-.-:-;-:-:,:-:-jll8 Leachate System Improvement Plan :,:,:,:,:,:,,,,.,.,.,.,.,-~iw%--.@%~ 3& • Begin more frequent pumping of landfill using existing system beginning the first week of March. • Upgrade pumping system to continuously pump leachate as soon as possible. • Begin obtaining information immediately on new treatment equipment. • Continue to monitor landfill data. • Confirm leachate removal rates. • Begin pumping leachate from new wells. • Purchase and install new treament equipment. NCDENR -EPA Region IV February 16, 1999 IS- Landfill Leakage ~l@K:.,,.,,...❖ •• , •• -•• =.=.=.== •. =.=:=: ,······· ·. --.··· ;;;;,;;;:;:::,:::·::::::·:·•···•···••/ .'////?: e Directional drilling under landfill will be used to investigate for leakage. e Directional drilling data is additionally needed to define scope of detoxification. NCDENR -EPA Region IV February 16, 1999 ::::=:::=::::::{:::::::;::::::::::::::rn;wm.%fill"m -/~ /i/,r~ SovA Jv'! 7f ~35.16 1-llJ· 7f 3 3't. t? St;f. 9f 33'(./'f ()c,,f_ 1<T - Mv. 91 {)~c.. c;( 33;;,.~·>6 '53'f.l ;z. -;FqY). 11 33/,(3 -s3s.1s- reb. 11 3J3, ID .33y.65> MtJrr. 11 --333. (/ lrf(-11 -335, C/). ... -Parts Manual for Oil Lubricated Air Compressor Model Nos. L6560V / LC6560V SPECIFICATION CHART Model No. L6560V LC6560V Horsepower 6.5 ----- Displacement CFM 15.2 15.2 Bore 2 7/8" 2 7/8'' Stroke 2" 2" 'Voltage-Single Phase 240 240 Minimum Branch Circuit Requirement 20amp 20amp **Fuse Type Fusetron Type "T" Fusetron Type "T" Air Tank Capacity 60Gal.ASME 60Gal.ASME Approximate Cut-in Pressure 100PSIG 100PSIG Approximate Cut-out Pressure 125 PSIG 125PSIG SCFM @ 90 psig 9.4 9.4 SCFM @ 40 psig 11 .9 11.9 * This unit was not designed to operate on 208 volts. TABLA DE ESPECIFICACIONES Modelo No. Potencia Desplazamiento CFM Orificio Carrera del Piston *Voltaje-Una Fase Requerimiento Mfnimo de Conexi6n **Tipo de Fusible Capacidad del Tanque de Aire -GAL Presi6n de Arranque Aproximada Presi6n de Corte Aproximada SCFM @ 90 PSIG SCFM @ 40 PSIG L6560V 6.5 15.2 2 7/8" 2" 240 20Amps. "Fusetron" Tipo T 60Gal.ASME 100 125 9.4 11.9 * Esta unidad no ha sido disenada para funcionar co alimentaci6n de208V. TABLEAU DES SPECIFICATIONS Modele N°: LC6560V Puissance en c.-v. ----- DeplacerCFM 15.2 Alesage 2 7/8" Course du cylindre 2 po *Tension a phase unique 240 Exigence minimale du circuit de derivation 20amperes **Genre de fusibles "Fusetron" Genre T Capacite du reservoir d'air -GAL 60Gal.ASME Pression d'enclenchement approx. 100 Press ion de coupe-circuit approx. 125 Pi3/min standard (SCFM) a 90 PSI (pression manometrique) 9.4 Pi3/min standard (SCFM) a 40 PSI (pression manometrique) 11.9 * Cet appareil n'est pas destine a fonctionner a 208 volts. **A circuit breaker is perferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is con- nected to a circuit protected by fuses, use dual elementtime delay fuses (Buss Fusetron Type "T" only). Call our Toll Free Number 1-800-888-2468, Ext 2 , to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs. When ordering repair parts from your local Authorized Service Center, always give the following information: • Model number of your product • Part number and description of the item you wish to purchase **Se prefiere el uso de un rompecircuito o disyuntorelectrico. Use solamente un fusible o rompecircuito quetenga la misma capacidad de corriente que el circuito ram al que alimenta el compresorde aire. Si el compresor de aire esta conectado a un circuito protegido porfusibles, use solamente fusibles con doble elemento de demora de tiempo {fusibles Fusetron tipo "T" de Buss). Llame a nuestro numero de telefono gratis 1-800-888- 2468, Ext 2, para obtener la direcc6n del centre de servicio autorizado mas cercano para ordenar piezas y reparaciones cubiertas par la grarantia. Cuando ordene piezas de repuesto de su centre de servicio autorizado local, siempre indique la siguiente informaci6n: • Numero de modelo de su product • Numero de pieza y descripci6n de la pieza que desea comprar **Un disjoncteurestpreferable. Employerseulement un fusible ou un disjoncteurdu memetauxque le circuit de derivation surlequel lecompresseurfonctionne. Si lecompresseurest connecte a un circuit protege par des fusibles, employer des fusibles retard es a double elements {Buss Fusetron de type T seulement). Appeler notre numero gratuit 1-800-888-2468, Ext 2, pourobtenlr l'adresse du c~ntre de service autoris6 le plus proche pour commander les pieces de rechange at pour Jes reparations sous garantie. Lors de la commande de pieces de rechange aupres du centre de service autorise local, donner toujours les renseignements suivants: • Numero du modele de votre produit • Le numero de la piece et la description de !'article que vous desirez acheter ~ DeVILBISS AIR POWER COMPANY MP5-L6560VB 10/30/98 ~ 213 Industrial Drive • Jackson, TN 38301-9615 Air Compressor Diagram _ ,~ Key No. TORQUE 11 70 to 80 In. Lbs. 17 10 to 12 Ft. Lbs. 40 10 to 12 Ft. Lbs. ~ 26 34 2 Parts List KEY NO. PART NUMBER DESCRIPTION 1 SSF-953-ZN Self Tapping Screw (4 used) 2 CAC-22-2 Belt guard 3 SSF-8113-ZN Locknut 4 CAC-2-1 Bracket 5 CAC-362-1 Beltguard closure 6 SSP-9401 Connector 7 SSP-7812 Nut-sleeve assembly (2 used) 8 SSF-8553 Connector 9 SSP-7811 Nut-sleeve assembly 10 C-BT-224 Poly-Vbelt 11 SS-391 Setscrew 12 C-PU-2861 Motor pulley 13 SUDL-65 Key 3/16" x 3/16" x 1 1 /4" 14 CAC-4205 Cord Assembly 15 MO-3022-1 Motor 16 CAC-1331 Pressure release tube 17 SSF-928 Cap screw 5/16"-18-1" (4 used) 19 CAC-4336 Pressure switch 20 SS-3222-CD Pipe plug 21 CAC-95 Manifold 22 TIA-4150 Safety valve 23 GA-370 Gauge 24 SSF-985-ZN Screw (2 used) 26 CAC-1003 Isolator Washer (4 used) 27 SSV-6 Globe valve 29 SSF-8150 Hex Nut 34 SS-2707 Drain valve 36 SSW-7367 Strain Relief 37 SS-2110 Nipple 38 CAC-437-2 Check valve 39 CAC-357-1 Outlettube 40 SSF-3152 Cap screw 5/16"-18 x 3/4" (4 used) 42 AC-0171 Compressor pump assembly • 3 Parts List AC-0171 Oil Lube Compressor Assembly KEY NO. PART NUMBER DESCRIPTION 55 56 57 60 v' 61 • 62 • 63 64 • 65 66 v' 67 X 68 X 69 X 70 71 72 - 73 74 75 76 77 78 79 80 v' 81 82 83 84 85 86 87 88 90 SSF-6627 CAC-4213 SSF-955 SSP-9401 CAC-291-1 CAC-294 CAC-4212-1 CAC-54-2 CAC-55-1 265-19 CAC-207 265-410 SSF-927 AC-0205 SSN-1018 AC-0169 SSF-925 DAC-276 265-16-1 AC-0203 SST-104 SSP-486 SSP-505 265-2 SSN-1014-ZN SSF-3039-ZN 265-6 Stud 3/8"-16 both ends (1 used) Head assembly (includes valves and screws) Screw, 3/8"-16 x 11/2" (5 used) Connector body Head gasket Intake flapper valve -square comers (2 used on head) ~ Screw #5-40 x 1/4" (8 used) ~ Restrictor plate (2 used) Exhaust flapper valve -beveled comers ro--- (2 used on valve plate) ~ Valve plate assembly (includes valves, restrictors and screws) Valve plate gasket Compression ring (2 used) Compression ring (2 used) Oil rings and expanders Piston (2 used) Piston pin (2 used) Piston pin plug (4 used) Connecting rod assembly (2 used) Includes (2) SSF-927 screws (Key #75) Screw, 1/4-20 x 11/8" (4 used) Crankcase and cylinder Wavy washer Oil Seal Screw, 1/4"-20 x 7/8" (8 used) Base Base gasket Crankshaft Ball bearing (2 used) Pipe plug (2 used) Oil plug Flywheel Belleville washer Cap screw Vent Filter (2 used) 88 8 l 86 X Available as part of Ring Kit KK-4313. v' Available as part of Gasket Kit K-0159. • Available in Valve Kit KK-4275. Recommended Oils -One Stage Compressor Units Use a compressor oil such as SAE 20-20W SF motor oil. (Crankcase oil capacity is 16 fluid ounces.) Under extreme winter conditions use 10 weight oil. Multiviscosity oil, 1 0W30, will leave carbon deposits on critical components, reducing performance and compressor life. 81 Key No. 55 57 63 75 79 88 Torque 25 to 30 Ft. Lbs. 25 to 30 Ft. Lbs. 13 to 17 In. Lbs. 7 to 10 Ft I he 9 to 12 Ft. Lbs. 15 to 20 Ft. Lbs. --------------------DeVilbiss Air Power Company• 213 Industrial Drive• Jackson, TN 38301-9615 M-AC-0171-Rev. 6/21/96