Loading...
HomeMy WebLinkAboutNCD980602163_19821216_Warren County PCB Landfill_SERB C_Revised corrected pump information-OCR.. R. E. BEUMER C. LCUTTING ELI LEMCOE C. N. LETELLIER W. LITTLEFIELD SVERDRUP & PARCEL G. R. PENNINGTON 1-:sc.1st:ER!i<-ARCHITI-X'TS-l 'OS!o,TR t.'CTI0:-1 ~IAS A Gt:Rs :.1:.111 WJ-:"'T ~IF..'1J()WYIEW ROAD St 'ITF. 11-1 (.ilU•:•;x~BOHO, SOHTII C.\.HOf.lSA :.:T•lOT W. H. RIVERS G.E.ROSENKOETTER H. G. SCHWARTZ, JR. 8 . R. SMITH. JR. 1. R. VERON R. C. WEST J. D. WHITFIELD December 16, 1982 Mr. Jim Lineberger Jim Lineberger Paving & Grading, Inc. Route 2 -Box 77A Gastonia, NC 28052 Subject: PCB Waste Disposal Site Warren County , NC Dear Mr . Lineberger: JOHN . PARCEL 1928-1965 L. J . SVERDRUP 1 928-1 976 91 9/85!5-9260 Please disgard the previous page of pump information which was attached to our letier dated 12-15-82 and replace it with the attached sheet. Sorry for any inconvenience, there was a transcribing error. Very truly yours, cc: T. C. Karnoski, Solid &Hazardous Waste Mana&ernent Branch/with enclosures .... -Revised 12-16-82 PUMP NO. 1 Pump No. 1 shall be Homelite Model 111DP2-l complete with 3HP, 4 cycle gasoline engine or approved equal. Pump must be positive displacement type capable of pumping a minimum of 5 gallons per minute at a suction lift of 25 feet. Suction and discfuarge shall be two inch. Pump shall be connected to suction and discharge lines to allow for vibration during pumping. Pump shall be securely bolted to the pump house floor to prevent movement. PUMP NO. 2 Pump No. 2 shall be Homelite Model XLS2-1A complete with 2-cycle gasoline engine or approved equal. Pump must be centrifugal type capable of pumping a minimum of 55 gallons per minute at 50 psi. Suction and discharge shall be two inch. Furnish 15 feet of suction hose complete with end strainer. Pump shall be connected to the sprinkler supply line with a flexible type connection to allow for pump movement during start-up and vibration during pumping operations. PUMP HOUSE Pump house shall be a prefabricated metal or wood building 8 feet long, six feet wide with a minimum door width opening of four feet. This building shall be supported on concrete blocks and have a wooden floor which is heavy enough to carry the weight of the pumps and operating personnel. The building shall be anchored to the ground to avoid overturning by the wind, but care shall be taken not to damage the underground PVC liner when placing anchors. I -------------1 ' t E.f/STl/t'tf r/.lTEA .JY.STEAf I I. --------- --_! #, ....... /l'il.11/1/ltJfl.SE --••••-< rPVM,""I ·,l • 41 SCH. fO P.Y.£". f,(I.JT/Ntf ilh•£,f 1£A<NATr rw,u.111£0 eoll'N£ert11rs FOIi All J{JINTS l£1U·/IATE l'VMP/Ntr, SPAAT /,f.l/~ATltJK SY.ST.£M IU!JJ. LANPFILl -WA,f,fIK <°OVNTY ,N. e. CHA/t'6E 0/IOE/11'1 SYE,f'OHVI" ',".#A't'El $CAL,£: /YON,£ /JIIAWN: /J.N.11. si-.rn:11,3 "AT£: ll•l5-IL