Loading...
HomeMy WebLinkAboutNCD001810365_19880809_Martin-Marietta Sodyeco Inc. (Clariant)_FRBCERCLA RD_CERCLA Submission Sandoz Chemical Corp. - Design Review Groundwater Recovery-OCRI I I· I I ·1 I I I I I I I " ·I .... I SANDOZCHEMICALS Sandoz Chemlcala Corporation P.O. Box 669246 Charlotte, North Carolino 28266 704.827.9651 Telex B10.649.2224 · Mr. Patrick Tobin Attn: Mr. Jeff Crane U.S. EPA Region IV 345 Courtland St., N.E. Atlanta, GA 30365 Dear Mr. Tobin: August 8, 1988 This letter is to transmit a submittal package for design review of the CERCLA groundwater recovery and monitoring systems and soil treatment from Superfund areas C and D of the Sandoz, Mount Holly site. The contents of the packet are as follows: List of Responses (from "Superfund Remedial Design and Remedial Action Guidance", OSWER Directive 9355.0-4A) "CERCLA Groundwater Recovery Systems Work Plan" by Law Environmental "Prefinal/Final Design" by MoTec, Inc. Addendum to "Prefinal/Final Design" by MoTec, Inc. dated July 11, 1988 Letter from w. M. Archer to Patrick Tobin, dated May 18, 1988 Letter from Patrick Tobin to W. M. Archer, dated June 6, 1988 Letter from J.P. Straley to u. S. Fish and Wildlife Service (D. Migmogmo), dated August 3, 1988 Letter from u. S. Fish and Wildlife Service (D. Rackley) to Giezelle S. Bennett, dated September 16, 1987 When your review is completed, a meeting may be beneficial to review any comments with you and your staff. If a meeting is held, we would ask that our proposed soil treatment contractor, MoTec, Inc., be present at this meeting. If there are any questions, or if I may be of assistance in any way, please do not hesitate to contact me at 704-827-9651. . ' , cc: Mr. Doug Roberts -NCDHS Sincerely, , w~ /Yl. ~ William M. Archer Environmental Manager I I ..... I I I I I I I I I I I I I I . II ;,', II I .,, ... ,,. , .' -.. ' . . -RECEIVED EPA/ RECIOH IV ~UG 11 9 3] AM '88 ·w,,sTE EHGltiEER\NG SECTION ' ,. --,r -- - ---·--- - i\lR MONITORING DATA SHEET . ; . ;---- Sita« f'roled Name ------------:--------;------- PrcJec:t No. _______ _ - Data: _______ _ 1'9rll00{1)Coftectlng Data•---------------,-------;---:-------------------:------ Ganaral Opora!lon and l.oca!fon al Slt•~----------------,---,---;----------------------- !nslrument Typ•, Maka, Model ---;L-:::,_,:::--------------------------------------- / ~ .-,11n1men1 s«lal er ID No. .L::::. attery • •• • B Ch ck R ult Dal• or last Calln~on er °'if f \ \ Date ol last Servi<:$ Contarnnent(a) Su•p•et,' ,L A . I ,_ I "'~ 1//f~~) E"1)loyoa Name llme Comments ..... II Breatilng Zena RHdlng (e.g., dJrallon, cousa~on ol reading) Spedlle Locallon -WDli<Pha' Monlt0<ed /"-. ' 1. (/ ·1 ,/ ./"--, 2. I I / /1 I 3. (J / < / 1 I'---. <~ .......... , J I I I"" '" 4. 5. ' I I ·-',, ') "',._. 'J ii "/ j -. •. -8. -- V ' ',. 7. 1 " II. / I '· / . ~/_. 9. 10. / i . Genoral Con::nonlc: Si3nalJr■ ol Person Responsible lor Dsla: -------'----------------- Date Signed ____________ _ I •• I I I AuuENVU~ I To I "PREFIMA\... /f1"'A'-De:s.1~"1 • I I .. I ; I I I I I .. I I •• I I I I I I .. •• I I I I I .. I I l\.loTec, Inc . . ·v:tllc)··c:cn1cr Mall P .0. llolli .lJM Mt. Julic1, TcnnC!>!>CC' l7122-0JJM Phone: 615-754-9626 SOLVING TODAl''S ENVIRONMENTAL PROBLEMS WITH TOMORROW'S TECHNOLOGY July 11, 1988 J. Paige Straley Senior Environmental Engineer Sandoz Chemicals Corporation P. 0. Box 669246. Charlotte, NC 28266 Dear Paige: Here is the addendum for the soils in Area D. MoTec, Inc. would propose to remediate the contaminated soils in Area ·o by utilizing a newly developed aqueous soil washing technique. The soil can. be recycled to achieve the desired treatment level. The residue may then be released to on-site disposal . The tasks will include front end loader, soil residue, and replacement surveillance, but the provided by Sandoz. excavating the area by backhoe and/or washing/biodegradation, dewatering the of residues. MoTec will conduct process final analytical verification will be The area to be excavated is an arc approximately 90°, outside circumfer'ence of 66 feet. The width is 10 feet excavation will go five ( 5) feet down. The client will the contaminated dirt with clean fill. The volume is 150 and 200 ~ubic yards. with an and the replace between MoTec projects the 3 -4 weeks. The treatment system. generators. duration of the project to be approximately process water will be released to the water Power requirements will be met by on-site The price for this project will be $17,982.54. MoTec would request one-half or $8,991.27 pay-out upon mobilization and the final $8,991.27 to be paid upon completion of the project. If additional material is uncovered, an additional contract will be negotiated. I .. • I I I I I I I .. I I I I I I .. I I .... -·" ,• - ..:.•:,. • ,_1.·.-.,-~.. ~-.· J. Paige Straley Sandoz Chemicals Corporation Page 2 July 11, 1988 MoTec will also complete any technical writing as requested by Sandoz. The fee for this activity is $100 per hour or $500 for an 8-hour day. This will include the "Prefinal/Final Design," Operation and Maintenance Plan, QA Project Plan, and a Site Safety Plan. More details on these will follow. We would anticipate a cost of about $1,500.00. 2e?~ J1.m League Manager of Technical Operations JL:eb I •• I I I I I I I .. I I I I I I .. I 11 I I I SANDOZCHEMICALS Sandoz Chemicals Corporation P.O. Bo, 669246 Charlotte, North Carolina 28266 704.827.9651 Tele, 810.649.2224 Mr. Patrick M. Tobin Director, Waste Management Division U.S. EPA Region IV 345 Courtland St., N.E. Atlanta, GA 30365 May 18, 1988 I Re: Sodyeco Superfund Site I I .. I I I I I I .. I I Dear Mr. Tobin: In a conference call on Friday, May 13, 1988, between myself and John Dickinson, Jeff Crane, and Giezelle Bennett of EPA, we concluded that the RCRA permit modification process would cause undue delay in initiating the CERCLA remediation. Mr. Dickinson requested that we write to you about this matter. In September, 1987 EPA issued the Record of Decision (ROD) for the Sodyeco Superfund Site, now c~lled the Mount Holly Plant of Sandoz Chemicals Corporation. The ROD specified, in general terms, the remedial activities to be performed and a recommended schedule for work to proceed. The ROD also specified that the work was to be conducted under an amendment to the RCRA Part B permit. It had been our understanding both from language in the ROD and from discussions with RCRA staff that activities specified in the ROD would proceed under our RCRA permit once it was issued. Unfortunately, the RCRA Permit, which is very close to becoming effective, would need to be modified if it is to specifically address the ROD remediations. Sandoz is in favor of proceeding with remedial activities as expeditiously as possible, but in any event at a pace that is technically feasible under the RCRA program without a RCRA permit modification. We do feel that it is important to secure some type of approval from EPA's RCRA staff of the planned remedial activities before they are initiated. However, since much of the remediation is going to be performance based (using ARAR clean-up standards), we believe approval of the general remedial methods and goals should be sufficient for both parties. Sandoz has continued CERCLA work both through collection of additional evaluation of remedial alternatives. since issuance of the ROD, field data and in Surface water samples I .. I I I I I I I .. I I I I 2 continue to show no indicator parameters present in either Long Creek or the Catawba River. A repeat soil sample taken in area C in the area that was believed to be the most contaminated showed much lower contamination levels than previously found. The soil treatment options listed in the FS have been further studied. Each of the four options appears to have some inherent problems. The effectiveness of soil flushing is not easily verifiable, and concerns about this concept have been expressed by the State. The in-situ steam stripping effectiveness is also hard to verify for our particular circumstances. Thermal treatment is likely to be slow and difficult to implement because of permitting considerations and constraints. The logistics and mechanics of material handling associated with soil washing make it less attractive. Since the issuance of the ROD, two other treatment options have been looked at. Biological treatment (which was listed as composting in the FS) appears to be an effective option. Biological treatment was evaluated this winter in a treatability study that we feel strongly supports this concept. In-situ vacuum extraction also appears to be a viable option based on clean-ups of chemical leaks into soil accomplished with this technology. Sandoz has obtained proposals and quotes for utilizing each of these technologies to remediate the soil in area C of our site. We believe either of the methods in this paragraph would be acceptable and could be initiated, with your agency's approval, ahead of the ROD schedule. A preliminary schedule for the program is as follows: I. Groundwater Recoverv Svstem Plans Submitted EPA/State Approval Start Installation Soil Treatment (Areas C & D) Plans Submittted EPA/State Approval Start Implementation III. Area B Cao Plans Submitted EPA/State Aooroval Start Construction 60 days after EPA/N.C. DHR concurrence with program 30 days after submitted 60 days after approval 75 days after EPA/N.C. DHR concurrence with program 30 days after submitted 60 days after approval 120 days after EPA/N.C. DHR concurrence with program 30 days after submitted 60 days after approval .I C .. I I I I I I I ,. I I I I I I I 3 Sandoz looks forward to your concurrence with the program outlined above. We will be pleased to proceed immediately upon written approval of the approach described above. WMA:aj cc: J. Dickinson J. Crane w. Meyer J. Swallow G. Bennett M. Smith c. Case Sincerely, William M. Archer Environmental Manager I -. I I I I J; otfj I I .. I I I I I I .. I I UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION IV JlJN O 6 1988 4WD-RCRA Mr. William M. Archer Environmental Manager Sandoz Chemicals Corporation P.O. Box 669246 345 COURTLAND STREET ATLANTA., GEORGIA lOltliS Charlotte, North Carolina 28266 . Dear Mr. Archer: JThank yru for yrur letter of May 18, 1988, in which Sandoz expressed ·willingness to proceed with remedial activities (as rutlined in the Record of Decision) prior to the RCRA pennit appeal being settled. We have reviewed the program and schedules contained in the letter and hereby approve both. We are also approving yrur prcpcsal to evaluate biological treatment and in-situ vacuum extraction, since both of these technologies were considered in the Feasibility Study. We have discussed yrur prcposed program and schedules with Mr. Jerone Rhodes of North Carolina, and he concurs with rur decision to approve Sandoz's May 18, 1988, prcposal. Sandoz shruld follo,; th~.Remedial Design and Remedial Action (RDRA) guidance manual in develq:iing the program in detail. If yru have any questions abrut the RDRA guidance manual, contact Gizelle Bennett at ( 404) 347-7791. The primary contact for this work is John Dickinson of my staff. Please contact him at (404) 347-3433, if yru have any questions abcut this project. . We appreciate Sandoz' s willingness to proceed with site remediation activ-ities while the RCRA pennit appeal is being settled. It is rur under--standing that Sandoz will drcp the appeal upon receipt of final approval of the RCRA Facility Investigaticn (RFI) guidance plan of study for solid waste management units not included in the RI/FS under CERCIA. This acticn wruld be beneficial to EPA and Sandoz because the pennit cruld then provide a fonnal mechanism for approving the remedial action under RCRA at the site. Please ccntact me at (404) 347-4154 if yru have any questicns abcut this matter. Sincerely yrurs, Q~ rr(J6l1,,;,., Patrick Tcbin, Director Waste Management Division cc: Jerone Rhodes, NCDHCR William Hamner, NCIBCR I .. I I I I I I I .. I I I I I I .. I I ·· SANDOZCHEMICALS Sandoz Chemicals Corporation P .0. Box 669246 Charlotte, North Carolina 28266 704.827. 9651 Telex 810.649.2224 Field Supervisor U .. s. Fish and Wildlife Service P • 0. Box 3 3 7 2 6 Raleigh, N. C. 27636-3726 Attn: Ms. Debbie Migmogmo Dear Ms. Migmogmo: August 3, 1988 Sandoz Chemicals Corporation is proceeding with a "Superfund" cleanup at our Mt. Holly, N. C. plant. As a part of the EPA Record of Decision (ROD) approving our plan, Sandoz must consult with the Fish & Wildlife Service to make sure that endangered or threatened species are not adversely impacted by the project. A short description of the actions we plan to take follows. I have also included copies of relevant pages from the ROD and the Remedial Investigation . The remedial plan for A and Bare merely to put an engineered asphalt cap over the areas. Area A already has manufacturing buildings and asphalt paving, so the action here is to maintain the pavement in good condition. Area C is presently used as a gravel-surfaced parking area for trucks and trailers. Area C will be remediated by an innovative technique whereby bacteria biodegrade the contaminants. Details of this system are given in an enclosed attachment. The soil from Area C will be backfilled to its original location after the cleanup. Area D will be remediated with an innovative surfactant/ bacterial method. The soil will be used as fill after it has been cleaned. Area E. The only disturbance in this area will be that seven shallow wells will be drilled. This is a field/second growth woods area near Highway 27 transected by a drainage swale. The swale is typically dry during summer. Areas A-Dare highly disturbed areas on an industrial site. It is most unlikely that there would be pctential habitats for endangered or threatened species. Area Eis part of an old farm . It has the pctential to be wildlife habitat. However, we I .. I I I I I I I .. I I I I I I .. I I • 2 emphasize that the only activity that will go on here is that recovery and observation wells will be drilled. This will provide a very local and temporary disturbance lasting no more than 2 weeks. Impacts such as sedimentation or denudation of the ground will be mitigated. We expect the impact of the well drilling to be quite minimal. I trust that the information included in this packet is sufficient for you to make a determination concerning potential impacts on threatened or endangered species. However, if you need further information, of if I may help you in any way, please do not hesitate to call me at 704-827-9651. I would appreciate it if you could give this matter your immediate attention as we are under a time constraint from EPA. Thanks for your cooperation. JPS:aj Enclosure Sincerely, i-lI~1 J. Paige Straley, P. E. Senior Environmental Engineer I ~ I I I E I Aff'EN'D I)(. D I I .. I I I . I I I ~ I I I .. I I a n D I I I I I ~ I I nc:dlln ana :)alety Manual followed by doffing of the gear. Coveralls should be removed by turning them inside out. A procedure appropriate to the degree of contamination should be established. A general sequence of doffing procedures is outlined below. The extent of washing required, or modifications to the sequence, may be specified as appropriate. 501.4 Typical steps in decontamination: I. 2. 3. 4. 5. 6. 7. 8. 9. / ' rinse work gloves and boots; / .~. '···,, ; , ' ' wash and rinse outer protective coverail ,i'nd respirator; , .. ....,I '-..._, "·, untape mask, wrists, ankles; ',, ··, Ir-...., ...... ,,--.../ remove respirator mask (also gogo/s, if worn); remove boots; . // , wash work gloves and boots; remove outer suit (also glo~es~r~.haJ); wash and rinse surgical glo~s; ,/ / remove iMer Tyvek coverall; "'--('•,""' IO. remove surgical glo1ei• ""v· II. shower, if desired, and~- c . . . fD '\\1 /B -p /d 1 ontamenzauon o econtaml{lat19n y-ro ucts All . . '~d .,,--.... . l (' \ \l ') ll . . ) contamm~e7ma tenee., g oves, cover a s, decontamma tion water g~nerated during decrtz_minayb?-: shoulcspe collected and containerized. Final disposal procedures depe d on.,th_rlevel of contamination of the materials. HAS-PRO501 HS-501-2 June 1987 I .. I I u D D m I I I I I I ~ I I Hazardous \t'aste Management Practice Health and Safety Manual OPERATING PROCEDURE HS-501 501 .0 Decontamination .50 I. I Purpose < '-I I Decontamination of equipment and personnel sh9uld be performed to limit the migration of contaminants from hazardous waste sites''and between work zones on the sites. .501.2 Equipment Decontamination / /'-. -,, / / '~-.. ,,, ' ., ' ' <..._..,/ ' "-.._ . ', '-., ',,w/ ? All major reusable equipment and{her t,_ools used for site investigation activities should be decontaminated prior (~eil.'!'.,i/g>the site area. Cleaning should consist of scrubbing to remove encrusted materials fo(lowed by a detergent-and-water wash and potable water rinse using a high-pressu~'-I~~ume water spray or steam cleaning unit. Additional rinses w~hothe~ 'sucii as methanal and hexane, may be used if warranted by the natur\~hem~s encountered. DKoo,.miaa<io~d b•~"' " • dosigaa<od oq,ipmoo< decontamination area on1thr,it~.) An exca~~ed sump may be used to collect wash water as needed. Fo/(g de:,9nta_mina.t.!Q!l, 'the clean equipment should be stored on plastic sheeting. ~ (/ The~de~~g~~ vehicles (e.g., trucks, etc.) should be cleaned prior to drivJg rem of~~ite. At the conclusion of site work, all major equipment should be ~~ clean) jmg the method described above. .501.3 Pers~lmmauon . Decontamination of personnel should be performed at a designated location on the site. Personnel decontamination should consist primarily of detergent-and- water washings and water rinse of exterior protective gear to remove contaminants, HAS-PRO.501 HS-.501-1 June 1987 I .. I g n n 0 E I ~ I I I I I I -. I I I .. I I D D D I .. I I I I I I .. I I Hazardous Waste Management Practice Health and Safety Manual OPERA TING PROCEDURE NO. HS-I 02 10?.0 Heat Stress I 02.1 Purpose The purpose of this OP is to provide general information on heat stress and the methods that can be utilized to prevent or minimize the occurrence of heat . / . ' stress. ', ;'"··, -._ ·' Adverse climatic conditions ore impar;,t~nt considerations fn planning and conducting site operations. Ambient temperature effects can include physical ./ / •. discomfort, reduced efficiency, personal i_njur'y, and Jncreased accident probability. ........ ,, .-.' Heat stress is of particular concern while w·earing impermeable protective garments, since these garments inhibit evaporative body. coail~g. '· ', ....... . ... 1--------. '-...../ I 02.2 Requirements \ \~ ---------. \,\\;/>/~-/ The NIOSH criteria docu·ment· for heat stress recommends that ' ·, environmental monitori~~tl\er pre~~ti>e measures be adopted in hot worl< environments. Howeve5, ,~ pr~vis~:_~~_:not directly applicable to employees who ore required to wear lmpermegble prot~tiye c_lothing. The reason for this exception . th . bl I '>-..h I I .. _h . f h" h . . f 1s at 1mpermeo e c ~ng ,prevents t e evaporation o sweat, w 1c 1s one o the most import~ng 11'.!._echqnisms of the body. There is no recognized health standard pr~!ec7rr-fo\\rk'er~eoring impermeable protective clothing and respirators jn hot environ}ents. i I \ < '~ ) The~~ h<}s 9dopted a TLV for heat stress. These guides relate to work/rest regimes.~:/ 01n.an2 HS-102-1 October 1985 I .. I g D H D I I I I I I .. I I Hazardous Waste Management Practice Health and Safety Manual I 02.3 Additional Hazard .. The use of Personal Protective l::quipment of the types commonly used for hazardous waste work can place stress on the body. One common problem with the use of personal protective equipment especially in hot environments is heat stress. Protective clothing can cause excessive sweating_ c:ind can prevent the body from properly regulating body temperature. 1 o~.4 Types of Heat Stress I Heat stress is the aggregate of e?vi~onmental and physical work factors that constitute the total heat load imposed .on .the body, The environmental factors / / / '•,~ of heat stress are the air temperature, radiar\t .heaf exchange, air movement, and ,,.. ..._, / water vapor pressure. Physical work contributes ta .. _the total heat stress of the job . '·, ·-.. by producing metabolic heat in the body in proportic;in ·tQ. the intensity of the work. r-'· J The amount and type of clothing cilsooHec..t the heal' stress. '\ \~------. •. \ I /---~/ Heat strain is the series af-._physioJagical responses to heat stress. When the strain is excessive for ~posed iil~~vi~ual, a feeling of discomfort or distress may result, and, finollyjo/-.eQ,~~isorder '~o_y ensue. The severity of strain will depend not only on th7 mogni~e--af_t.h!!_, prevailing stress, but also on the age, physical fitness, deg(ee .tt oc.c:'limatizatian; and dehydration of the worker. ' "/ / H it JI' d~ '-I sed t d 'b f th e/ • 1sor e~ a,gene_za term u o escri e one or more o e following /;lated cll~~iti~~.of il:nesses: ·-• ~eat cramps)-painful intermittent spasms of the voluntary muscles ~lo~/';Prd physical work in a hot environment. Cramps usually occ~r heavy sweating, and often begin at the end of a work 0191.an2 shift. · • Heat exhaustion -profuse sweating, weakness, rapid pulse, dizziness, nausea, and headache. The skin is cool and sometimes pole and HS-I 02-2 October 1985 I .. I I I H B I I I I I I -. I I Hazardous Waste Management Practice Health and Safety Manual 102.5 conditions 0191,an2 clammy with sweat. Body temperature is normal or subnormal. Nausea, vomiting, and unconsciousness may occur. • Heat stroke -sweating is diminished. or absent. The skin is hot, dry, and flushed. Increased body temperature, which, if uncontrolled, may lead to delirium, convulsions, coma, and even death. Medical care is urgently needed. Methods of Controlling Heat Stress As many should be of the following control measures as are appropriate to site ' .' utilized to aid in controlling ·heat stress: • • • • / ,. ( / ' ;' _ ... / / / ..... , Provide for adequate liquid~.}o'r.i:pl9ce lost body fluids and replace water and salt lost from sweating/·. Encourage personnel to drink -... .... . more than the amount required to ;atisf/-~hirst. Thirst satisfaction r------, / is not an accurate i(ldicatorof...Qqequote ·salt and fluid ·replacement. '· ~ -.._ ___ ~eplace fluids with il(~fe\r, C:pmmer_£~1 mixes such as Gatorade or ' ' I Quick Kick, or a comblnatic\n, bf these. \ I Establish a work,regimen· .. th(lt will provide adequate rest periods for cooli_na;;;own\ \!'fhis m~---~quire additional shifts of workers. /' I , I ·, Wear c?ol_~ng dejlces~such--"1 vortex tubes or cooling vests beneath proteotive,garpientS:--.1 ' ~ I . • Take all br~s:~ a cool rest area (77°F is best). • ~ove'l~rm~I~ protective germen ts during rest periods. • / ~~~n otherv'tasks to personnel during rest periods. •/ ;inform pers<r~el of the Importance of adequate rest, acclimation, ·<~•,;;/;"tho pt•~",;~ of h~t ''""• HS-I 02-3 October 191.lS I .. g n 0 D D I I I I I I I -. I I Hazardous Waste Management Practice Health and Safety Manual 10"!.6 Mani taring 102.6.1 Temperature The heat stress af an area can be monitored by the Wet Flulb Globe Temperature Index (WBGT) technique. Where heat stress ,me1nitaring is required, a heat stress monitoring device, such as the Wibget Hecit_ Stress Monitor (Reuter Stokes) shall be utilized, -, .,1·--·-.......... , ... ,. ,/ I •-., ·...,_ The W!:IGT shall be compared to the Tl-\reshold Limit Values (TLV) outlined 1•. •,. ' I by the ACGIH TLV guides, and a work-rest reg 1 imer?shall be establish~d in accordance - ( with the WBGT. Note that S°C must be subtracted from the TL Vs for heat stress I .' listed to compensate for the wearing of jmpfrme_abl~ protective clothing. ', __ / / I 02.6.2 Medical ;-----.__ In addition to the provl~ions-of tlie-W.CC medical surveillance program, '\ \ --; on-site medical monitoring of per~evh'aWbe:-performed by qualified medical personnel for projects where ~at stres\is (major concern. Blood pressure, pulse, body temperature (orol),ld body weight\sh~ld be token and recorded a minimum ,,,----, \ \ , of three times daily 7ifto "fOr~ at mid-Jhift, and ofter work). . "'"' .. , ... ~-~ z-J A/.A1~enc~· Governmental Limit Voli }or Chemica\ Substances in the Work Industrial Hygienists, Threshold Environment, 1984-95. '" "" ) ) Oti hi~ J.~., undamentals of Industrial Hygiene, National Safety Council, 1981. "-'V Notional Institute for Occupational Safety and Health, The Industrial Environment -Its _Evaluation and Control, 1971. 0191,0n2 HS-102-4 October 1985 ---- Projocl Name and tlumbe<: -- - . --AIR SAMPLING.TA SHEET == == Date: Calibrallon Do~ and S«lal No.: ------------------ Dato of La.I Calil:ulicn: _______________ _ Gane< al Locadon and Of !Ion Sarrpod· «• Tlmw Ueod: ____________________ _ I I SaJTl)le No. A Sa""'• Type and Maf)"ffl I~"-... Parson Wearing Pump ! L \ \ I Purrp Type and Seriel No. / , , A ~ ~~~ Specific Locadon and Opal allon (/ l ./ _/"-., Dal• cl 58""'• ,- Tlrrw on I / /t I f... / < I I 1"-' Tlrrw on ··, ' / -~'" I ,/ I" ------'/ ·-'-· Run Tlrrw{s) I I I, .. '• ) ---..... , ·' ··._! T olBI Tlrrw '-. i /, I ' I I '✓ '-·,. Pr•-5~ Colora!lon P.un(a) ' V I ·,> ·•. ', Post-Sanpo Calbrofon Run{•) ' ' I ,, ' I '· .. . I .. Cnlruatod S..""'• Volume I I , .. Cortoctod Swt>f • Volurrw .' / / ( Sampling Cor.ldona Commonlt and Obs&rvatb.,: Sampler Siga2h.n ______________________ _ --,,-------'I l!!!!!!!!!I I!!!!!! === == == 1111111 -.--f ltl0.120 t9 C1I 0.. XVII (7-1-l7 Edition) opinion rroin the u:1.tnlnln1 phyalcl&n Nan: £natnttrtn1 conLroll whkh ma, be tonWnlnc: the followlna: feulble are the u.c or pr-eaurt&ed cat. or :~ce may rault In an IDLH •ltua-a.Jrbome levela of hu.a.rdoua aub-(A> The reaulta of the medlc:aJ exam-a,nt.rol booth.I on equipment, a.nd/or I.he on. 1t.ancea and hea.Jlh ha.r.a.J"da ln order to lna.tlon and teal&. a.. or rrmot..elJ ~raled mat.er1&J handlln, <v> The le•el of protection provtded determlnt the appropriate levt1 of em-<B> The phya.lclan•1 oplnlon u Lo equipment. Wort pn.ctJcea whk:h may be by PP!: aelectton ■hall be lncreued plo)'tt prot.ectlon needed on alte. whether the employee hu &nJ detect-feulble att remorlnc LIi ~nU&.I em-when addlllonaJ lnfonnallon or. alte ( 2) M a flral at.ep, a1r monJtorlna ed medical condlllona which ld ploJeea from polenllal upo1un durlna: condlllona ahow lh&t lncreued protec-aha.Jl be conducted to ldcntlfy any pta.ce lhe employee at lncreued ~~u of ~1;!1•~ ~i.:;e~~1:;;: !u.~:r; Uon 11 n~ to lab l"educe employee IDUI a.nd other danaeroW ■ltuatlona. material lmpa.lrment of the employee'■ ~Ible hu.uda. P O :~poeu.n:s 1':!, ea llahed pennliml• ■uch u the presence of na.m.mable at• health from wort In haz.a.rdoua wut.e e n:poaurc It.a for hu.ardow ■ub-moepherea, oxy1en•derlclent environ• opcrallon■ or emersency reep<>nae <UJ <Whenever enl1neertn1 conlroh: at.ancea and health hu.arcla. «See Ap-menta, \Oxlc level& of airborne con-CC) The phy■lclan'a recornme~ded and •od pn.ctlces are not feasible. peodl• B for culdance on .clectlnc tamlnanta, and radioactive materi&la. llmll&Uono upon the employeu u-P'J'I: 4haJl'l>e U&ed L<> reduce and m.&ln· PPE enaembles.l C3> u a minimum, periodic monltor-■lcned wort.. . ~.)•~~ to or below lhe pennla• Non: The Incl of prol.eclJon pnmcled Ina: ■hall be conducted when: CD> A otaumenl that the emploJee/ ~.~~• Ur;,<JIUre limit.. of aubatancea us· mar be -when oddlllonaJ lnfom>&-Cl> Work beclna on a dlllen:nt por-hu been Informed bJ the ph,-alctan oJ UAted by 29JCJP,R Part 1910. Subpart Uoo o< mu condlllona •how that d<ao ...i Uon of the Ille. the ~lo or the medical e•amlnallon f-\ _ \ prol,dlon will "°' raull In huanloua npo-IUl COnt&mlnanto other than th°"" and an, medical condlllona whlch-'re-; CIU) The .. Pl?Jer ah&l,I not lmple-•w-alnemploreea. pn:vloualy Identified are belns hut• quire further exa.m~.aUon or #eat,.: ment • .;cheaolt:rof ~p:Plo7tt rt"letlom ("fi) Penon.aJ prot.ect.lve equipment dled. menL · '-"-u a meana f// CUllpllance wlth.pennla-aha.II b< ■elected and U&ed L<> meet the lllll A dlllerenl type or operation la 1111 The WTlllen c,plnlon obtaJMd bJ '11~1• n~un, )lmlt,a. / "-, '-._ requln:mento or 29 CF'R Part 1910, Initiated '•-•·· drum openlna u op-the emplo7er aha.II not re-real ai,ed/lc '-12> ~ngiJ,ttff,.g .-lrob. 11>0rt PrGC· Subpart I. and addlllonal require-poeNI L<> nploraL<>ry weU drillJns_l flndlnp o, ~ unrelaled lo oc-'Hcq, __ cu,4 -~ jm,l<cfh., ,VMlp-ment.. apecifled In thla aecllon. 11,l Employeu are handllns lea.kins cupaUonal expo■-Ure. fflfflt Jor .-.bl~~ ._JLOt -rr:Q'\L.lated in (4) Totall•-.-en.cap.uUaUng chtmtcGI drum.a or cont.aJnen or work.lna" tn C,) kcordkttp("". Ill An accurate Svl,parl Z. An appl"Ol>Cl&U -<X>mblna-prol<clit>< ,1111,_ Ill ToWJy-encapc,ulat-areu with obvloua liquid conl&mlna-tecord of Ute med.Jcal au..r-veutance re-Uon of en.rlneeH.na cont.rota. work Inc aull materlw uaed for Level A pro-Uon Ce.,., a IPUI or laaoon.) quired bJ J>O,raCT&Ph Cf) of thll -Uon practices. 'and' penonal prolecll,e /'-..._ lect.lon aha.II prot.ect employ ... from 10 Aller huarclow wute cleanup ■hall be ret.a.l.ned.. Thia record ■hall bie equipment ah.all be estahUahed to .,.,..~ /the pa.rtlculu har.u-da which a.re Iden-operaUona commence, the empJoyer retained for the period &pec1rled and reduoe and m&Jntaln employee upo-//. U!led durtn,: alle characlertr.allon and aha.II monitor thoee employ ... ILltelJ meet lhe crit,,rla of 29 CF'R 1910.20. aun: to or belo,r the eal&bllahed per•/ .// analyall. L<> have the hlah""l polenllal upo-lU> The record required In para. cnis,,lble e•poeune llmJl lor;'hu:arclo111 <.• / IU> Totally-enc:apoulattns aulto ahall ■urea L<> thoo, huarclow, aui.tancea ~h C!ll1lll> or 1h11 aecllon ahall In· auba"""""" and health h&ur<la -·not b< C&;>&ble of tnaJnWntns i,o.tUve a.Jr and health h&urd, moot ILltely L<> be elude at leul the .loUowtn& lnlorma-l'el'Ulaled by 21> CPR Part UIO, Buti'""' , l / pn:uure: CBee Appendb A.I pre.ent abo,e est&bllahed permlaalble lion: part Z. ·,_,-· '-... / Cllll ,Tol.l.llr-encapculattns aulto aha.II npoeun, llmlto. The employer ahall IA> The name and aocl&I aecurlt:, CJ> l'tr>o""1 r,rouctl"" eci,alpment .,. -be C&P&bl• or .pn:YenUna 1n.,an1 lest ample frequently In order L<> chan.c-number of the emplo7ee; l«Uon.. (I) Pel'90Q&J protectJ-.-e equJp-.' I / p.i ld.k.aae of more lh&n 0.5 peroenL t.ertze employee ex,l)OlrUtt. The em-CBI Ph:,alctana• written oplnlona. rec-m<0nl IPPE> ahall b< oelecled and uoed / . «Bee Appendix A.l ·,_ / ployer may ullllze a n:pn:aent&llve ommended Ilmltallona and result.. of which will prot.ect employeca from the /.I/ / UI · hnonal prolttllt>e ,eq11lp,nml aunpU,,. appro<t.Ch by documentlns ••amlnallona and lesla; huarda and polenllal hu&rda lheJ 1-' . -«PPK> p,wrum. A penonal prolecUff that the employee,, and chemlcala (C) AnJ empJoree medk::a.l corn-are llteJy to encount..er u Identified I / equipment pro,n.m ■hall be ·at.ab-.choeen for monJtorinc a.re ba.aed on pie.Int, n:laud \<I up05ure L<> h&Ard-dutins the die ch&racl.erlullon and I O _ llahed for hourdoua waale operations. the crilerla at&ted In the lint aenlence oua 1ubalanca; ILnaJ)"li&_ ·n.e PPE prosn,m aha.II addrea the.. of thll p&nanph_ l:mployen are not IDJ A copy or the Information pro-IU> PelWNI protective equipment lollowlna element..: ··required L<> monitor employ ... en-YI-lo the eumlnlni: phr■lclan b:, oelectlon ohrill be hued on an evaJua-lh Bile hu&J'da. / ; P4'ed In Ille chanclertr.allon oper-. the employer, with the exoe;,Uon of Uon of the performanoe charactena-IU> PPE oelectlon, , / allona covered by PArlllTaPh (cl of thla the al&ndard and Ito~ Ua ol the PP!: nelaU,e L<> the require-(till PPE .-. / ., oectlon unleu auch wort lnvolvN poll· J!] ~.,':l"!'!.'::f'.'~m:f:wl menu and Ilmltatlona or the ,11e, lhe llv> Wort mlalon duration,,, alble .. poeure L<> hu:ardoua aubatancea C r l.au-opedflc condlllona and dun.lion. / lYl PPE tno.lnlenance and •L<>rase, or health huarda. mrn( [or £171 pro on-{ n· and the huar-da and pot,,ntl&J hu.&nla lvll PPE deconl&mlnallon, C muillon p m,-{I) gfo«rlng co~ IOO.-l P'11':llcu ,.,,., ld<nlllled 11,l the Ille. c,u, PPE lralnlns a.nd proper lllllns. ~ pv{ ol Lh.''!'i'ecy and PPK /or 11<l>■14..-rev,,laud t,1 SMI>-(IU, Poolll•e Pl'U8Utt oell-oon-«viii> PPE donnln1 and do!llna pro-heaJth prosnn, required In ~ph parl Z. Ill ~rln& cont.roll and brea!hlna Wl>Ar&lla or poelllve pn:a-ceduru. Cb>Cll of thll aecllon. lhe employer wortc Practloea mall be ln■Uluted lo sure &Jr-line n:aptnt:.:-a e<iUlpped with Cb> PPE lnlpedlon. ahall develop and Implement a alle reduce and malntaln employee e•pc;-an eocape air aupplJ ahall be U&ed In 1•> PPE ln·uoe monlL<>rins. . alelJ and health plan meetlns the re-■ure to or below the pennlaalble expo-JDLH conditions. (xi) £n.Ju&Uon of the dfecth-encaa qulr-cmenta of P&,r&&"'ra.ph 0><2> of thla ■ure llmlLa of ■ubat.a.ncea r-c(Ula.ted by (iy) ToU..111--enca.peulaUnc chemical of the PPE Pl'tlCTIJn, and Rctlon for each hu.u-doua -wute oper-29 CFR Part 1910, Subpart z. .. ~pl prot.ectlve •ulto (Level A rolectlo 1 . Cxlll Umltatlona durtn1 lemperatun: allon. to the exl-t:nl that 1uch controla and ah.LIi be U&ed 1n condition.a: :·here co" I extremes. <2) Sitt •aid'¥ and health plan.. The practices are nol leaalble. lact of the •l:Jn by th ha.urd ~-<hi Monitoring. Cl l Air monltorinr alle aa.!ely ILlld health pllLll. .-hlch e oua ■u · ■h&.11 be uaed t.o Jdentlfy and QULlltlfy ■hall be ■vaih.ble on the ■lt..e tor in· 0-p ni-1 5a,-1y ■ne1 ""Ith ,..,..,;11., L,--. f I. ___ ;20 ~◄R 347 --~r ·0.12. --~ -·.a,. -(7-' -'dlfu 'I l!!!!!!!!I == OCCll p O\.lonoti k1itty eM1i ne-atth ";;•In., ~~ I!!!!!!!! !!Im == == =-,-... 1.aa •~lion by emptoytea, their desl,nal• '''zJ!:"!i!J.", "B!™ and r;nta(rtf.'1 rd rcpreacnt.a.tlvea, a.nd OSHA per-.on-( l) e t , rums an con a ncn nel, ahall addreu lhc u.rety and uacd durtna-the clc11.n-up ahall meet htollh hau.rda or each phue or all.e lh• appropriate DOT, OSHA, and opcrallon a.nd lnc.lude lhe require-EPA r-eaulaUona for lhe waaLea that mcnta and ptocedurea for employ~ lhey contain. protection. 01) Druma a.rut conlalnen aha.ti be Ill The all.e ■..rely and hKllh plan, lnspecud and lhelr lnl.elTfly aha.II be u a mtnlmum. ahLll addr-eaa the fol-aaaured prior to betna moved. Druma lowtnr. or c<mta.lncra I.hat cannot be Inspected <Al Namee of key i,erM>Nlel and al· before beln1 moved bec&uae of lna.ccea-t.emat.ea reaponalble for alte J&.fely and ■Ible a.t.on&"e conditions ahall be moved health and appolnlmenl of • all.e lo' an -Ible locallon and inapecled aa.Jely and hea.llh officer. ~·rior1o further handllns. !Bl A u!ely and hea.Jlh rlak analJ&la viii Unlabeled drums and conlalnen1 for e&eh all.e Luk and operation. aliall be conal~red ID conlaln huard-!Cl bnployee lra.Jnlna ... lsnmen ),u. aubolanoea \nd handled aca>rdlnlr-<Dl Persona.I prot=U,e equli,n,enl/ IJ unUI the conl.enla ue PoOlllvely lo be uoed by employeee for each of ldenlUled and W>eled.l'-..... lhe all.e Luu and operallona lbe~<l•l Bile J1per&Uom 1hlll ,~ orp-conducted. ~-lo lnlnln,lr,e lhe am~l ·01 drum (El Medical mneWa.nee requ ~nu.lritr JI\OTeD>el)L "· '"' menl&. <•> Prlor'ID mb,emenl of dnuna or <l'l 1'1-equehCJ' and l,--ol a!r monf. con1&1nen1. 1JJlemplo7eeo expaeed \lo lorlnc. pcraonnel monll<>rlnc, and en-the tnnafer j>POr,llon ahall_be ,rarned •lronmenl&I aunpllna lechnlques and of the polenU~ huardo oaaoc:laW , lnat.rumenl&Uon lo be uaed.. Melhoda wllh lhe conlepla of lhe jdn\ma or' con-' of malnl.enanct &nd callbrallon ol l&Jnel'll. '-...., / _ / / monll<>rlnc and aampllna equipment !vii U.B. ~enl pl Tranat>orta-lD be uaed. Uon apecifled aalvaae ~ or con-. </, (0) Sile conlrol meuurtL Wnen Uld aull&ble I ql.WlUU ... ...oi <HI Deconl&mlnatlon proceduns. proper ahoorbenl ahall t,e· tepl_.ava.11-<ll Slle'1 ot&nd&rd operallnc prooe-able Uld uaed In att&l where apllll,-...._ I d\J.R!L le-ab, or ruplwa: J:n&Y occur. '·-......_ ... -✓--........_ <JI A conllnnhCJ' pion mttUna the <TIil Wbere m&Jor apUII mar occur, a -, requlremenu of r,o.rqn.phl < 1 )(II and aplll eonl&lnroenl Pro«r&m ahl.ll be Im-/ · 111<21 ol thll aectlon for Ale and erloc-plemenled ID conlaln and loola~ lhe live n:sponaea to emef't'en:cit:a lnclud-ent.lre yotume or the hu.ardoua mb-ln1 lhe neceaa&q PP!: and olher 1t&nce belna' tranalened. .._ equlpmenL <vlUl Drwna and eonl.t.lnen \.hal <Kl Confined apaoe enlry proce-c:umol be mDTed "1lhoul rupture, dures. . leu...,, or spill..., 1hall be emptied 1111 ~lrJ briellnsa aha.II be held lnlo a 10W>d conl&lner ualna a devloe prior lo lnlllaU.,. any 111.e acllvilJ and cl-lfled lo, the malerl&J belns trana-at auch other Umea u nec:::eaa.tJ' to fcrred.. enaure lh•l employees a.n: apprloed of !III A lrt'Ound-penelrallns 1yjtnn or lhe all.e ■..rely and hKllh plan and ol.her ln,e of delect.lon ■yal<,m or lhal ll la belns followed. dcYice 1hall be Wied lo eallmal.e lhe lo-11111 ln.pectlona 1hall be con:lucted callon and deplh of drums or conlaln, bJ lhe alle Alely and health olfloer era. or, In lhe ab■enc,: of thal lndh1dua.J. !al &II o< covertnc lnalert&I aha.II be a.nolher Individual octlna on behalf of remo,ed wllh caullon ID prevenl drum lhe employer a.a neceaa..r, t.o ~t.cr-or conl&lner rupture. mine lhe dfecllveneaa or lhe 111.e <•II l'lre ntlnaulahlns equlpmenl ■..rely and hKllh plan. Any ddlclen-medlnc lhe roqulremenu of 29 Cl'R clea ln ~he eUecllvcneu of lhc ■lt.e Pa.rt UHO, Subput L aha.JI be on hand ■..rely a.nd health plw aha.JI be cor-Lnd rndJ for uae lo control •mllll rec1.ed by lhe employer. flrea. 348 <xii) When lhert I.a a reaaonable pae-albU1ly of nunma.ble a.tmosphere belns PtUenl, materla.J h&ndllfl41 equlpmenl Uld hand loola aha.JI be ol lhe type to prevent aourcea of lJnltlon. (2) ()ptmfog drvm., And rontalMn. lime u their ha.t.a.rd to employee., la properly auesaed. l~ > Shock. aensHive ~tu.. CAtrn.011: Bhlpplhs of ■hod. •tr~llln •aata m■.J ~ prohlbU.ed under U B. l>t· p.l\menl of Tnll,a,port.■.llon rtr0l■.Uona. Employen w\d lhelr ■hlppe:n ■hould refer lo 49 CFR l1J.1l uM'.I 113.r,O. The f0Uowtn1 procedurea aha.I\ be fol-lowed ln ueu where drum& or c:on-uJ.nera a.re beln1 opened: <I) Where a.n airline reapln.tor Az. a mlnlmwn. lhe followlna apecla.l ay.tem la uaed. connecllona to lhe pr-ecauUons aha.JI be u..ken when bahk of air cyllnden ■hall be protect-druma a.nd container■ conWntn, or ed from cont.amlnallon and lhe-enllre auapected of contalnln1 ahock-aenal-ayatem ■hall be prot.ect.ed from phyal-live wutea u-e ha.ndled: cal dalnaa•. <II All non__.,nUa.l employee,, aha.JI <111 Employees not actually ln•ol•ed be evacualed from lhe uu. of lruu-ln Ol'.Jentn, drum& or cont.a.Intra aha.JI fer. be kepl a we dlatanoe from lhe drum( <Ill Malert&I handlln1 equipment or conl&lnera belna opened. ■hall be provided wllh ex.pl011lve con-Ull) If employtea mual wort near or t.ainmenl devices or prolecllve ahlelda adjacent t.o dru.ms or cont.a.lnen belna to prolect. equipment operat.on. from opened. a suit.able ahJeld that doea not explodlns cont.a.ineta. lnt.erfere with the wort openUon ( Ill> A.n employee a.la.rm ■yatem capa-ahaU be placed between the employee ble of befns" perceived above aw-round• and lhe druma or eonla.lnen belns lnJi llihl and nolae condlUono aha.JI be opened to protect the employee In cue \Lied to all)ll.l the commencement a.nd of accidental exploelon. completion of explosive wut.e han-<lvl Conlroll for drum or c:onlalner dllnJI acllvlll.._ openlna-equipment. monltortn, equip-<Iv) ConUnuoua communication■ ment. and fire auppreulon equipment. (l.e.. Portable rad.Joa. hand al.-nala. •hall be loca.led behind the exploolon-lelephonea, u appropriate! ah■.11 be r-eslatantbe..rrier. matnt.alned between lhe employee-ln-<vl Dnum and c:onla.Jnen Iha.II be ChUlf< of lhe lmmedlal.e huidllnJi uea opened ln'suCh.a '"m&nner that excea: and lhe alt.e l&.l'ety and hca.llh olflcer tnt.erlor -':pn:uurt.~wlll be aa.fely tt-or comm.and poel until auch time a.a lleTed. II. preuun, ·cannot be relleved lhe handllna operallon la compleled . fJ"Om ,& remote loca.tlon, appropriate Communication eQulpmenl or melh-ahleldlns ·ahlll be placed belween lhe oda lh&l could cauae 1hoct RNlllve / employee and the druma or contaloen tn&teria.Ja to explode aha.JI not be uacd. "-... to· nduoe Lhe tlak. of employee lnJu.ry. <v) Druma and conlalnen under . _, h1) Ernployeea ■hall bOl ■land ·upon··'-.Prt:aau.re, u evidenced by bul&lna or or wort ftom drum, or conl&tnera. .,,.,tuna. a.hall not be moved until such (3) Electncal ma.t.nial. Jian.dljap ~. Ume u the cause for exceaa pre.saurc L, eq1dpmcnt. Elect.rtea.J m&t.eiia.J · h&n-dttermlned and appropriate conta.J.n-. dlln& equipment uae-d lo tr-a.nafer ment procedurea have been lrnple-dnima U\d cont.a.lnera aha.JI: ·· mented lo protect employet:a from ex-<l> Be poettloned and opent.ed to ploelve relief of the drum. mlntrnbe aourc,ea of tsnlt.lon related to <vl) Dnmu and containers contain• the tQUlpmenl from l,nlt.1n1 v1.pon re-ln1 p&ek&6cd laboratory wutea &ha.11 leaaed from rupt.ured druma or con-be considered to contain ahock-&.ensl-Wnen.. or live or exploelve rnalcrla.la unlll t.hey (Ill Nttt lhe nqulre:menta of 21 have been chan.clerbed. CFR 1810.301 and be of lhe &pproprl· 1e1 Laboratory ll><Ule J><1Cka. In &ddl-at.e dectrica.l clualfk:allon for lhe ma-lion to lhe requirement.a of pa..nan.ph lerlala bcln1 handled. (l~!>) of lhla ~lion. lhe followln1 prc-(U .Rcu:UOA.CUvt wcutc.s. Drums a.nd caullon.a ahall be lak.en. as a minimum. contaJncn conl.a.Jnlng n.dloacllve ln ha.ndlln&: laboratory waste pa.ck.& wula ahall not~ handled until such <lab p.ack.s): 349 --r :o.u ---:• -; a, -'I (7-1 -lltk• ----Ou._;:,_:.,1nel --·-·'Y •~=-... otth 11!!!!!!1 1!!!11 -,r -II., L § '.{ ... 20 OJ l.&b pack.a ■ha.11 be opened only eea or equipment to contaminated em-· when neceaau-y and then only by an ploycca or equlpmenl. clea ■hall &ddreaa, u a minimum, the work acllvllles If necessary, Lo lower Individual k.nowled1cable 1n the ln-(4) AJI employeea leaYU\I • conwni followln1: ba.ck(TOund noise tn or-der l.o apttd apecUon, cla.ulflcaUon. and ~-nat..cd area ahall be a.pproprtat.ely de· <A) Pre-emersency ptannlns. communication, and to bcaln emer1en• Uon or the conl&lnen wtt.hln the l»Ck contaznlnaled.: all clothlna: and ul · <Bl Peraonnel rolea, lines or author-cy procedures. accordln& the h&U.l"d, of the wut..ea. menl Jeavlns a conlamln&t.ed eq P-lly, lra.Jnln&, &nd cotnmunlc:atlon. (0) Bued upon the Information (II) If cryst.alllne mat.erW la noted on ahall be a.ppropr1at.ely dlapoeed or (C) Emeraency recopitUon &nd pre-available at lime of the emer1encf, U\7 conl&Jner, the content. aha.JI be decont&Jnlnat.ed or ventlon. t.he employer ■hall evaluat.e the Ind-handled u • ■hoct..-cnalUve wute · (&> ~n~lnallon roced <DJ Sale dilit.ancea and places of denl a.nd the alt.e responae capabllllles unUI lhe content.a a.re ldenUfled. ■hall be monlt.ored by the :ite .:;rea reru1e. and proceed ..,llh t.he appropriate ('1) Sa.mpl1n.g drvnu and contcf'll-ttl. and health orrtcer M> determine lh:t.r (EJ Site aecurity and control. at.epa to Implement t.he on-alle emer-Sunpltns of cont..&.lnen and drum.a effect.Jveneaa. When ■uch proced lr CF) Evacuation rout.ea and proce-1ency response pl&n. ah.U be done In a.ocordance with a m roun4 u, be lnetfectl• u.ra duru. 131 01/-•lk em<'1>mC11 rupo,u,-tll umpllns procedun, whkh la part ol 'u, ,tepo al\o.ll be lo.ken u, e, approprl-IOI Decont&znln&Uon. Trulnlnp. Tralnlns for handlllll! oll-lhe alu, ll&felJ and hea.llh plan deYel• ~lklendea "-cotT<Ct any IHI Emersency medical ltt&tmenl alte emeraency reaponaea lnvolvln1 . Oped !or and aY&lla,ble u, employeea/~ 081 All '· i' enl and llrol aid. haz&rdoua aubelana,,i ahall be con-and olhero al the apeclll: worblte. / or deco~ tlo an~~IYi::,n~ Uoed Ill Emeraency alerlln1 and raponae dueled on a monthly bula and ah.U be Ill Shipping 11"4 l1"n>por1. ,All laminated or'rdlaf n • econ-procedures. al leul 24 houro annually. The lraln-Druma and conu.Jnero ahall ~be ldenU--111 Prolecll, ~h~-~ properly. IJ> Critique ol reaponae and follow• Ins ahall Include a, a mlnlznum ~-!led o.nd clualCled prior lo ment all ve/ 0 Ill! ,and equip. up. nltlon ol hu:a.nb. Klecllon. care. and · for ahlpmenL '-._ cleaned. •~de~ ~"":i,.~lna~ <Kl PPE and emeraencJ equipment. use ol pcroonal protective equipment Ill) Drum or container ~ u-eu ·needed · . ed -!'r ~ 12> Htut1nlo1U IOCUU operallon,, on• and a&Je opcrallns proceduru lo be ahall be kept lo lhe minimum number~ u ., ~ }" ma.lnl&ln .\heir el-.tk .,_.,,..,.c,, ruponu-{I) Trulnlnp. uaed al lhe Incident acene. -,, to ll&felJ ldenUIJ and cl.-J---n,ea. / ( '-,_ \ Tn.lnlns !or on-olte emer1ency re-Ill) /"roc,:dvru for handling Q/J-.tle IJ m,.u,rlala and prepue them for ~~l Jmpc:::J"I• _prou,ctlYe dolhlns aponae ahall be conducted In accord-.-..u.,,..,.c,, lncldcnu. IAI The senior transport. • c con . 0r}I likely lo hue can-t.nce with puacraph (e) ol thla ■ec· olllcer respondlllll u, an Incident ln-1111> 8l&&1na areu ahall be pnmcled I.acted h~u, aube~ ahall be ; lion; Yolvllll! a haurdoua oubetanc:,o or with Miequale ■-oce,1■ &nd qn:a ~;tam"':~ before belnf ttmoved 1· __,.,---....._ Ill> Procedvre1 /or h•uullh1g .tie wute ahall esl&bllah an Incident Com• CIY) Bulk.Ina of hu.a.rdoua wuta Ul> Emplo7ect1 •hoee /non .. ·lmpenne-/.,. to the element.a for the emerseocy re-.-ponders and thelT cornrnunlcatlona ahall be permitted only a.fur a lhor• able clolhlna-becom.. welled wtlh./ ..-; oponae plan required In -h ahall be coo~led and controlled rout.ea. 1 • emp o:,ee. / · ·· ;·~ Incident&. (Al In addJUon mand Syau,m UCB). All emersency re-ou1h characu,rlu.tlon or lhe mAl<oriala 1hu:ardoua aubel&nca •h.U ,Imm. edlate'. <1· / Ill< 1 ><II> above. lhe lollowlns element.■ lhrolll(h lhe lndlvldUIJ In chu1e of hu been compleled.. 1 remoYe lha.t. clothlna ·and Proceed to . aha.U be Included for on-elt.e emeraen-the JCS. It) Tclnk Gnd """'' prooed•ru. (I) •hower. Toe clothlns" •hall be dlapoeed -1 CJ reaponae plans: 18) The lndl-rldual In chars• ol lhe T&nb and nulla conlalnlns hasard-DI or cleconlamlnaled before ll_.18 re-"'-. Ill SJL<, ~hJ. layout. and pre-JCS ahall ldenlUy, lo lhc ntenl -•· oua ■ut.t..a.neea ahall be handled lD a moved from lhe wort. sone. ~._ · 1 t'Alllnl •~ther condition■. ble. all hu.&rdoua aubl!llancea or condl-manner .in,u.,,. lo lhal for ,!num and (10) Un&Ulhoriud empl01eea •hall / I Ill Procedures . .for .,cportJnc Incl-Uona p ..... nL conWnero. lulllll lnl<> eooalderkllon nol r-etnoYe prol.eclln clolhlns or / dent. to local. ort&le, and l.ed•nJ 10•• IC> Baaed on lhe hu:ardow aub-the ab.e of lhe t.ant. or nu.JL equipment from cha.nae rooma. . / ~nt.al a.aenclea. · _,.. at.a.noea and/or condlllona present, the Ill> Approp,uu, wit. or null en~ 111> Commercial laundrl .. or clean--. /1 · 18> Toe on-alu, emeraenc, rapo.--Individual In chU1Je of lhe ICB ahall procedu.-.. moellns pvqr,,.ph Ina e.t.abllahmenu lhat deconl.&ml• plan ah.U be a .. l>&Ble oecllon ol. lhe Implement approprl&l<, emeraency op-(1;(2><1><K> of lhla oecUon ahall be lol• nau, prot=tlve clolhlns-or equipment '-,. Sil<, SaJelJ and Bea.1th Plan. er&llona. and uaure lhal the pc.-.onal lowed whenever employee& mun enter ahall be Informed or the PotenUallJ · (C) The on...St.e e:nerscncr responae --.. prot..ecUve eo.ulprncnl worn la appro-a tank or YaulL hannful effect& of npoaurq lo haz. plan ah&.11 be compe.Uble &nd lnt.qral,-· prl~te !or lhe hau.rda lo be encoun• llln.,Wo;:"14mlnalloA. <II A de0c,n. u-doua aubow.cea. ed with lhe dlaaater. llrc and/or em•r•'. lered. However. pe~nal protective lam ion proccdarc ahall be dcYel· 112> Where lhe decon~lnatlon 1ency rccponae plans ol local, al&le, · equipment ahall me<:l. al a nunlmum. oped, coramunlcal.cd to em;,loyea and procedure lnd.lca.tes a need tor ahovcra and federal aaencles. / _. the cr1terl& cont.alned ln 29 CPR lmrilcmcat.ed before L"l)' employeea or a.nd cha.nae roorna,. they ■hall be pro-lD} The on--'t..e emersenc, l"eSPOMe Ul0.166<.c) when worn while pertonn-equlpment m&J enu,r snu on .ite -rlded and meet the requirement. of 29 plan ahall b< rchear-M:d ncula.rt, aa lnl !Ire 11&-hllns opcraUona beyond lhe where pol<ontlal fer upooun, lo hu-cm 1810.lfl. part ol the DYenJI t.nlnlnl pn,cram lnclplenlatqe. udoua aubst..a.nces e:a:l■t.a. (I) E,r~ 1'U:P01"'..U-C:1) Oeff.trol for 1.lte Ol;)er&tlona. · ._, <Dl 8elf-00nl.&.lned brea.lhiJ'll' appan.-(2) St.a.ndud opcral.ln, ;>root:dun:a h) An cmefi.t:hC9 iBpdhi@ vlan ■hall (El Toe or,-alt.e emersenc, respon.e lua llh&ll be worn al all t.lmee by per-•hall be d<Telo;,ed lo mlnlmbe em-be denloped c.nd lmplement.ed by em-plan ah.U be re•1e•ed perlodlcal.lJ aona harlnlr poulble expooure lo haz. ployee cool.a.cl wllh hu..a.r-doua sub-ploren to hLnjle &.nUclpat.ed emcr• &nd. u neceu.a.ry, be a.mended to keep ardoU& 1ubsta.nca or hea.Jt.h hu.a.rda at.&.nce■ or wllh equipment that hu · 1enclea prior lo the commencement of It current w1Lh new or ch&ndn1 1.ll.e durfnc ln~UaJ emcra:ency reapc,nae op-conL&.ct.e-d hau.rdow 1ubfit.Lnces... hu.udoua wu-te oper:.tlona. condUlona or lnforma.llon. en.lion&. Alt.er one year from the dale 13) Decont.arnlnallon ahrJI be per-Ull Ekm=u of ~n tme'V<ftC)I ,-,. I II") An employee alarm ayau,rr, oh.U or publlcallon or lhla rule only poalllve formed In a.rcu thal wtl! mlnlmiu lhe 1p,omt plan. The emera:enci· ruponae be lnz~led In a.ccordance with ti preaasure ■etr~ntaJned reapln.lon expoaurc of uncont.amlnat.e-d em;>Joy-pla.n fo:-on-1lte and oU-elle emera:en-· CPR 1"10.IB5 LO nollfy employeea of aha.JI be uaed. The Individual ln chuae a.n on-alt.e emeraency 1ltuallon, t.o ■Lop ot the JCS may dccreuc Lhe level of 350 351 --r - -- - --f 1910.120 29 Cfl Ch. XVII (7-1-17 Edltl.n) reaplnt.ory s,rot..tttlon worn by em-membcn of a HAZMAT te:&m. defined ployeca If It la det.ennlned by aJr monl-u employee■ desll'Jl&t..ed by the em-t.ortn1 or other documentation that ployer to plu1, patch or otherwise dttreulnc protec:Uon wlll not reaull In temporarily control or atop lea.ks from hu.a.rdoua e1:posura; to employees. contaJnen: which hold ha.r.ardoua 1ub-lEl The Individual In cha.rs• of the 1t.anceo or health ha.r.arda ahall be ICS ah&ll limit the number of· emer-slven lra.lnln1 In accordance with sency reaponK peraonnel at the emer-pa.ra.cn.ph (I )(3) of lhla acctton that ln-1encJ' alLe to thoee who a.re acllvely cludea the care and uae of chemical performlna emersencr openllona. protective clothlnc and procedures to Howner. c,pera.Uona In hua.rdoua be.,,.folloll(NI when workln1 on Jeakln1 &TH.I ■hall be performed ualnc the drums,, contalnera. t.&.nka, or bulk buddy ayatem tn pvupa of two or/ra.n.lp0r1.__ wehJ,clea. more. SJI> Memt,e111. of HAZMAT learns IP) Blld:-ap peroonnel ahalJ be aliall recel"'i phyalc:al e .. mlnallona olandlna bJ wllh equipment readJ fJ,v.:• eel.Ina lhe\ requlremenla of para. provide uot.t&nce or n,ocue. QuallJle<I ..-aph (I) of Ulla kcuon, bl.ale Ille ouppon pe...onnel, u a 1'1_n! <Ill> Peraorlfl .,h,tecUv~othlnc and mum. ahall alao be 11.andlna bJ,Wllh, equipment ,.. lie ~ ),1 ~AT medlcaJ equipment and lBllll>O~ membera ~hall m~t -U,e requlre-capabllltJ. nienla or·~ ,,,, of lhla ~•~n. 10) The lndhidual In eh.,.... of the lllJwl~,,...ponu \o~-ICS ahall deslrnale a aafelJ officer, «tloru. Upan complellon Df lhe emer-who la l..nowledaeable In fire flshllna sencJ responoe, If.fl la determined lhal 'I or racue operaUona and h&r.ardoua ll la neceua.,y ,to rrmOYe har.&rdoua out:.tance handllnc procedurea, wllh oubot&noes,<--t,eailh huanla ~ inale-_.:!llc reaponalbllltJ lo ldenllfJ and r1ala cont&mlna~ with fl-hent ouch u I e,,aluate huarda and to proYlde dJ.rec. contaminated aolJ or other element.a of / Uon with respect to the Wet7 of oper• the natural envtronmeJlt., jt.hen such/< ~7 at.Iona for the emersenc, at hand.. operatJoD1 &h.aJJ meet all the requtre,:. IHl When acUt1Ues are Judpd bJ menla of pe.rac,-apha (bl ~rou11h · In) lhe aafetJ officer lo be l&Nale and/or or lhla -n. / / N lo ln•oln an Imminent clanser condl-Im, m.,..,,.,,Hmt. Wortt an,u ahall Uon. lhe ao.felJ officer ahalJ hue lhe be ll11hled lo no[ 1 ... than lhe mlnl-aulhor1tJ lo alter, auapend, or lerml-mum IUumlnaUon lnlenallles llated In nale lh-acllt1U... The aafelJ olll-Table H-102.1 while any wortt la In / ;· cer ahall lmmedlalelJ Inform lhe lndl-pros,-ea: , I Yldual In ch~ of lhe JCS of UlJ' lie-·1·•., Uon, La.ten to mrnd. lhae hual-dll a&. Tw.r H-102..1. Mirr-. k..1.l.MNATlOfl an emerscllC7 110ene. NTEJCamE F -Ct.Hou U) A.It.er emersency oPera.Uona haYe 1"" <X>T 1 lermlnal.ed. lhe lndh1dual In ch&rse of '""' -,_., -lhe JCS •hall Implement appropriate deoont.unln&J.Jon prooeduNa. •:-----j __, _,-. <J) Approffd aell~ntalned com-•·----, £......_ .-d ... ...._ ---presaed a.Ir brecthlna ·appualua may -----. --be Liled with &.;,proTed e,-llnder. from ...... .,. Wd •••m ...._ •·----, INdbcr-a -· -~......,.,_and other LPPrvn:d .elf-<x>ntAJ.ned com-....,.,_ preaaed a1J' bru.thlna' ~tu, pro-•-----i ,--.. ....._ .., ...... :.::ao; o.t11 nded thl.t su=b cyllndera are cf t.he _.. ~ ~ ......_ ., ,o bJID1ot:dllwU........,llil..,...Wd....tl &LIDO e&p&citJ 1.rtd preuure ratlnl:. All ............ --..., -compreucd LI.: cyl~n \lled. w1lh .,. .._ d ..._ ~ a,p ..,._ ae:lf-cont&lned breathlnc c.ppa.ra.tu, _.., .,. ~ 1or -ro t. u...i ■ha.II meet OB. I>e:pa.rt.ment of Tn.na--,::i ~ ._ ~ _, ...cM-porta.Uon and National IJVt.ltute (or ---· "" ~ ~ ~ ~ Oc::up&llona.J &!ely Lnd He&lth cr1le-~ cir ...,. ........,_ t,o..-o •-rt1. ... --dN1G--. ... rdoor ~ . -----(4) Hc;z.:zr.!oua mal.ma.b Lea.nu '°--···· rn1-1~,.,.._,___,~. (HAZMAn. (I) Employ= .,ho c;.re 352 ---- -1!!!!!!!!11 -.--Occup at'-'wll iatety end Heotth ~amJn., loDOr I ., .. , ... ,20 <n> Sanltatfon at tnnporo~ aoort-~-cl) Polabk U>aler. <ii ade-qiiile""aupply of Potable water ahall be provided on the alte. UU Portable cont&JneB uaed to dlll-penac drlnkln1 ..-at.er ■hall be capable ol belnJ IIJhlly clooed. and equipped .,Ith a lap. Waler ahall not be dipped from contalnera. 1111) Any conWner used to dlatrlbule drlnklna wattr ■hall be clearly marked u to the nature or It.a content.a and not used for any other purpose. (Iv) Where ■lll&'le aervlce cups <to be uaed but once) a.re ■upplled. both a ■a.nltary contaJner for the unuaed cupa and a receptacle for dlapool1111 of the used CUPo ahall be provide<!. (2) Nonpolal>k ""'"''· Ill Oullela for nonpol&ble water. ■uch u water for lndualr1al or flreflrhllnr purpooea ahall be Identified lo Indicate clearly that the .-ater la unaale and ii not to be uaed for drlnkln11 • .,uhlnc. or cook-lnl" purpoeea_ (It) There ah&ll be no Cf"OU.-<oMec-Uon. open or potential, between a ■Y■tem fumlahlna potable water and & 1y11t..em fumlshlll&' nonpotable water. 13) ToUet. /adlillu. Ill Tollela ahall be provided_ for employees accordlna lo T-.ble H-102.2. ./ /·, · ... ,, Tuu H-102._2.~00LET FAOuTIEe talion re■.dlly available to nearby lollel faclllllea. (4) Food handling. All employees' food service faclllllea and operallona aha.II mttl lhe applicable lawa. ordl-nancca, and re1ulallona of the Jurladlc-lloru In which lhey are located . U> Temporo"JI ,leephig quarU'ra. When temporary 1leepln1 quarters are provided, they &hall be heated. vcntl-1•-• and ll11h-. {8) Wa,htng Jac:iUUu. The employer ahall provide adequate wuhtn.: faclll-tlea for employees ensaaed In oper-ation■ where hua.rdoua 1ubeta.nce11 may be harmful to employees. Such faclllllea 1hal) be In near proximity to Lhe wort.Ile. ln area.a .,here e1:pm:urea are below eatabllahed pennlulble ex-paeure limit.a and which a.re under the control of the employer. and ■hall be so equipped u to enable employees to remove hau.rdow ■ubat.anoea from themaelvea. 5 ~ 'i'k;"c '" Opm, llom Conducted "" r Ruource Coruervalion and Recove'Ji Acl o/ 117& tRCR.AJ. J:Snploy-cn con uclln1 operatiohs ape-citied In parqraph lall2llllll of thla aecllon ahall: U) Implement a hu.ard communica-tion Pr0£T&m meeltnr the require-ment. of 29 CPR 1810.1200; (2) Implement a medlca.J aurvelllance Pr0KT&ltl meetln1 the requirement.a of ....... o1 ......,_ -~ _,_. 1111 ~ pan.eraph (f) of thla aectlon; . ,, C3) Develop and implement a aa.lety -~ •..:. ··--.. / o... /·' .. and health procnrn for employees In-/ Were...,'°· .... ._ o. ~ .,.. ..o t ...,_ ,-volved 1n hu.ardow 1rr'&ate operaUons. / "'° «> _,,__ The Pl"OIT&m ahall be dealrned to '·-,~ ._*---j °:, ::..:;:._ _, 1 lft9,...., identify, evaluate ILnd control aa.fely ' and heaJlh huarda In their facllllles . , · , for the purpose of employee prot.ec-(lt) Under t.emporary field condl-'· t.Jon and provide for emersency re-tlona, provlalona ahall be made to ponae meet.Ina the requirement■ of .... ure not leaa than one ,tollel faclllly parqraph II) of thla aecllon; la t.va.llab1e. / ,. (f) Develop and Implement a decon-<llll Hu.ardow waale allea, not pro-lamination procedure In aocordu!ce t1de<I with a unitary .. wer, ahall be with Pua&T&Ph lkl of lhla aectlon. and provided with the followlna toilet fa• (5) Develop and bnplemenl a tra.ln• cllltles unleaa prohibited by . local Jnr prorn.m for employe-es lnvo)ved codes:: with haz.a.rdoua •ute operallona to CA) Pr1l1ea; enable each employee to perform their (8) Chemk:a.J toilet.a: a.aalcned duties and functions In a aafe (C) Reclrcul•Unc toilet.a: or and hea.llhful manner ao u nol to en-(D) CombUBUon t.ollela. da.neer them.aelvca or other employees. IM The requirement. of thi. pan-The Initial tralnln, 1h1II be for 24 IT&Ph for u.nlLallon faclllllea shall not. houni and refresher tralnlne shall be apply t.o moblle crews having lrtLn.Bpor-for eJ1ht houn annually or this pa.n.-353 -~r - -------- --l!!m f IUD.120 h C'tl Ch. AYn (7-1-, ,idltt..., ._ 0, llom •ly' lealt; •. alrt., · t -r-. § """.120 not been requl~ by other OSHA at&nda..rdl ah&ll be carried out from lhe elfecllYO date of this standard. ('1> NnD operuUon.,. Operations cov-ered by lhla aectlon Which are a~ a.Iler Much IS. 1981. shall be In com• plla.nce with thl.B accUon from the at.art of thelr operation. p-a.ph u to lhLl emploJtt. Employera who can ahow by an employee'■ work npertence and/or lralnlna lhal lhe employee hu had lnlllal lralnlns oqulvalenl lo lhe lnlllal tralnlns n,. quired by 1h11 panuaph. ahall be con-sidered u meetlna the Initial tralnlnS or lhla pa.ra.craph u to lhal employee. ~~rf-¥p c!alu-0) Ttulnlng an4 ~rovtilon.&. lnlllaJ tra.lnlna' An'DrDrm TO I UH.IH-HUUDOO• Wun a.nd medlcal 1unelllance u specified ~T•o•• ••a i:NDQa.CT Ruro"H by _,-..ph It> and If> of this oectlon )Iott._,,., Jolla"""# a,.,,,,.dica ..,... ., aha.II be commenced on the effccU•e;S-~■4&.torw p:Udtut ,o a.ut.t vn~-date ol lhll standard. and be lull1 Im-.., ,Jd ~"'°"'" t• .,.,...p1,109 .,,,,,. u,, op-plemented u aoon u pou,J,ble but no ro,ridt"•~.~-.}rEb a/ thU eectioa attPl later than Karch 1e; 1981. l:mplo1-,,.;E....,1a;''I"' ,...,.., to pn,u,c,-al· may continue ln I.heir work ual,111-.,. ~ ~a.cf kwf • pcno,ad pro-menll unlll lluch IS, 1981 lh~h l«Nw -• ,p,ci/1,d ta Appn,dur B t.ra.lnJna: a.nd mcdk:al e:1.&mtna\Jo°' arr reqw;frcid • f• /ri(rtf""tot1c.u q h&Ye not been co:nplet..ed 80 lol\C _ .. ~ .. ~~~12. ZOlcMIKUO~ (pMIKh•) feulble lralnln& and uamln&Uona / / /'::-._ "'-. h&Ye been completed. '-.._. ~ rz -P,lauo•.u Paoncnn 2.J ··ou tl1hl"'-for lhe purp,oec of lhll pra.cUoe the llmlLed now of a su under pruaun from lhe lnalde of a TECP SUit Lo almc.i,hett at. a prescrtbed preuure and lime lnLerv&J. 2.4 "Bh&Jl"'-Thb Lenn lndlcala a rn.&n· d&L.ory requlrtinenl. 2.& "Bhould"-Thll Lenn lndk:at..ea a rec-ornmrnd&Uon or lhal which II a.dvlaed but not required. 2.t •·w:ar-Thll Lrnn la uaed to •Late a p,erml..-lwe uat or an aJ~rnaUve melhod Lo a apeclfk ttQUlremenl. 1.0-SummarJ of PradJcc I.I T1>e TllCP sull la risually lnopeded and modified for lhe LeaL nu Lest appua-tm II alt.ached k> lhe suit Lo permit tnna-Uon to ~ pre-test suit u:p&NiCMl prcaure for remonJ of suit wrlnk.le:a and creuea. The pr-esautt ii k,wered Lo lhe tat p~ure IUld rnonlLored for thrtt mlnuLes. If the premurt drop II uceutn. the TECP •ult fall.a the tat.I and II remo-,td from 9itn1CC. AIL.tr leak. loeaUon and ttpa.lr the 1at b re---a,eat.ed. t.0-Requlred Suppllee (2) s,.,.,, ..,.4 ""11th J>tWTIIM. Th•"-----"""'""'"°faTllSTWDDO \· employer shall de-rtlop and l!nplemcnl TM, -/oeta-forth-lhe ,_,\.,..... a sa.lelJ and heallh Procram U re-1.orJ •nmplea 6t 1e11, trbieh ...., bo"uo,d 10 quired bJ _,-..ph (b)( 1) of thll aec-nalua!e CCJID.pt~ ..U.h puacn.phl , 4.1 Sourer of compr-eued a.Jr, Uon u 9000 u b feulble and han it. 1110.120(1)(4> (U) and «Ho.~· .J.at.a and 4.2 Tdt appu-&lua: for aull Lesltns lndud-completed and tmpJemcnL-d no iat.er other challeni"e aaent. ftl&1 be uted io lna a preuUtt me-uuremcnl dnke with • th&n March l,I 1811 n&Ju.ai.e compliance. / / acnalUvU.y or al lea.al V. lnch wa~r pu1e. (J) E g1n.ecri · troll. IOOTl-/ 4.J Vent .-.J,,.e-clONn ptup or 9e&llnl • "'1 C011 pn,c. ,1.. r.t1r-raco,...w,d s.,T,.. Tai/<! I.ape. ltcu, •n4 pcno,,al proUCNt>t cq11jp-I · 4.4 Boopy ,n.t.,r ooluUon and oort bruah. ne11t. U> The en...-tneertna eont.rola. 1.0 11 ope / 4.1 St.op ••Leh or appropr1al.e Umlns •u~ tat a.ppa.n.lw 1hould be Lest.ed befo;e a.nd &ft.er each Lat b)' cloalns off the end or the-lublnc Ulached Lo lhe aulL and .. urtn& • "reautt or Lhree Inches w;&Lu &&uae lor lhr-tt mlnut.es can be malnL&Jned. If a com• ponenl 1a removed for the tc:.t., th&l c:ompo-nenl ana.11 be rep)a.c::1:, ,nd & a,e-eond Leal con· ducted with another c..ampone-nl ttmoved lo permll a complt.Le Lest.I of the tnKmble. 1.1.4 The pre-Lal upanalon prnaurc (A) &nd the aull Lest pruaure {8) aha.It bt aup-p11ed by the 1ull rnanuf&d.urtr buL ln no cu,c ah&JJ lher be le-u lh&n; A-J tncha w&t.er 11u■e and 8 .. 2 lncha -.&I.er pua:e. The endlna: suit pra;aure-(Ct ahall be no lea than eo-,, nu of the Leal pre.urc (Bl; Le., lhe preuun drop 1tw:t not uceed Xt'li OU ot the tat preaure <8>. I.I.I lnflat.c lhe aull uni.JI the preaure Ina.Ide II e1;1uaJ lo preaure "A", the pre-lat. up&nalon •ull prr:uurc. Allow al kut one rnlnut.c t.o fill out the wrlnUea In the sull. Rekue .urtlc.lent a!r lo redt.tee Lhe aull prea:urr &.o pn:.ure "'B", the suit lat-prea-aun. Besin Umin,. Al I.ht> end of Uu-tt min· uta. record lhe suit pn:.urc u pnaure ··c," the rndina" aulL praau.re. Thr differ-ence between lhr. ,mil Leal pre-au.re and the endin& aulL tat 1 .... urc: <B-C) aha.J.I be de-fined u the aull 1,11uaurc: drop. I.I.I It the suit pre:uun: drop II mott than iO percent nu of the •ult L.esL praaure 8 durlna" the lhrec mlnut.e Lal ~r1od, lhe suit fa.Jla the L.esl and aha.JI be n:moved from acrvk:e. 1.0-Rrt.al Procedure wort. pracllceo and peDOnal prouctl,e .. ·· ,. ckvla/ "' oqulpmenl requln,d bJ -h I.I 'M>lo pnd.lce .........,... the .ahlllly of, , .. I K2) f lhll eectl -~-" be Im I a ru Uahl lot&lly-Una du,mlcaJ '-. A.0,:-&f•ly ~.Uona 1.1 II lh• sull la!U lhe lal chedt for I O on •n•u P e-prot«:t.he-aaJt. ma1.erial ae&ml. u.ct doauru '-~ / ·.. '-, leab bJ tnnailnl the aull &o preaurt A and mented U IIOOD U feulble i.lwt lm.ple-lo matnLa.tn a flaed S,0:..ttn pnaw-e TM / •. I c;:are &hall __ be 1&.kc:n '° proride the bn.-hl.na: or wlplnc the-ent.lre •ull tlncludlnl ment.&Uon aha.II be completed DO l&ter rmult. or Lhll p,-.cUoe a.Jlow the pa:. Uahl / .1 :;:rn:ct p~utt ai&f~ck~~ulred for aeama.. claaura, Jena ,-aa.keL&. 1lowe-1.o-61et:ve than IL&rch 11, IN'J. lnleartlr of a lot&l~latlr., c:httnka1 · / e ~~rce O ·:~P • r . JolnLa. eLc.) wtth a m.lld aD&P and waJ.cr 90Ju• (II) The en&inecrf.nl control&. wurk prolect.tft IUf\ &o be en.lualed. ..., I I ',, •-O-Ttsl Proced~, Uon. Ot..e"e the aulL for the forma.Uon of pracUoel and penonal protectJye 1.1 ~ or the 9UJ1. ma.tertab &o ' ./ ·· · ... 90&P bubbles., •hlch II an tndk:aUon or a e<;ulptDtnl -ulred bJ ~---h ponneaUaa. ~ and ~Uon / i I.I Prior IO ncb i.t. lllo laler shall lnl..Repalrallldenlllledlnu. ••~ ~-•-b ___., , /perlorm & risuaJ tn.peeUon of I.he ·tn1IL 1 • ~-•---" l.h -,-.m, II ""-~ In (1)( 1) of thla et:c:t.Jon an c.1.t.tJ.ng re-1 -~le tua.rdoua wt.t.a.nc:a • nol. de--· ·-Chcc.k I.he aull. ror aea.rn lnle-lrlt1 b1 nrua.n, ·• n.c...,.... e £ -..... .. su u ou._..._ qulremenLI of other OSaA st.&ndarda Le-rm.L~ bJ l.h• tut method. na..mfnln,; I.ht sea.ma and cenu, pulllnc on·..._ Te-al procech1n 1.0. a..nd conUouec to be required from the l.~DeecrlpUon or finM the aeam1.. r.n.wt I.hat all a.1r llliwlJ 11.nea. '-, . 1.0-Report tUecUn (ht.e of Lh!G Bta.nda.,.--d.. fU.Unp. n.or. a;tppen, MM1 n.Jves a.re secure· .. _/ U.) Sfte ~~t, c.nd f..co.ll.h ptca. The I.I Tot.a.llJ"-encaprul&led eht:mlc:&J pro-MKI a.how no aicna of dcLerloraUon: • · I.I r.ach TJ:CP .-ult ~ br th.II prac-s.lt.e aletJ and hea.l:.h pla..., requln:.-d b &ecUft 91.!IL (~ .-ull.l--A full bodf Pl"· , I.I.I ~ oft I.he nnt nhe1 UOna: wll.h _ Ucc ahalJ hue Lhe followtn, lnJormuJon rt· h 7 anent which ta conatruct.ed or ~.JYC I llnf othu normal Inlet or u:haust polnl.l corded. pe..rt..lT&P (1)(2) cf thll accUon and dolhlnl 11\&1.eriak: CPl'en t.ht:: •e&l't'r"• «•i.ach u wnbUk::al &1r line fltt.lnp or h,ce 1.1.I Unique klenUUcaUon number Iden-the emeraencr rcs:ponae pl&.n ~ulred Loc-ao, head. IL!'D\I.. a.nd 1ep; ID&Y co'f'er Lhe I plecc open1na, with 1.a.pe or other a,ppropr1-Ut,-ln& brand name. dat.c or pure~. mat..e-br pc.n.ua.ph (1)(1) o! thll aecUon we&r'tt'1 t-..s.Nla &nd feel with UihU,-a.I.-1 &Le me-ulill (c::apa. plllP. 11.J:Lur-e, d.c..). Care rt.&J of c:ona:t.nH:Uon. and unique flL fe-a.t.uru:; ah&ll be cocipiet.ed u .:>0n u fet..Cble i.:hed 1lons and boot.t,; compkt.elr ai--.ho:.tld be cnrcued L"l the ad.llnl: prooea e.a .• a.pecW bn:alhl.na: a.ppu&tua. b-Jl hO lLt!:r t.ha.n hbru.u-, 11, 1111. de.a U.e We&l'CT bJ ILlclf w In combl.n&JJon t)()l t.o da.ma.l"e any cf the 1JUll component&. 1.1.2 The aci..ua.l Y&Juea for L.esl pnauru, (~) Ctrtc:f,a op,e:uttoM COUw:ted with the 'dea.rer°I rnpln.t.or, .-qulpmml. 1.1.2 Clo.e all doiau~ ~blk&. A. B, and Cahall be recorded &Jon: with Lhe a:s:.4.a P.CR-(. The nqul..ret:lent.a a:pecl-&tOTI!&. and boo&a. . 1.1.1 ~ lhe suit for tnfl&Uon bJ spedfk ol»e-n-&Uon Umea. If Lhe endina fled by p-u-t.lTC.ph (o) of thl& aedJun 2..1 Prolcc:the dothlnc m.alerial-Anl' proridJnc: an lmproTiaed conn,rct.ktn potnl or-prea:un <C> "' lea Lha.n ~ of Lhe Lal 1n&t.eti&..I or c:ombl.n&Uon of maLer1&la u.ed ln the •ult for connecUnc an a.lrllne. AU . .ach presaun CBI the IJull ah&lJ be ldenU!ied u •~1 ~:::;:ltut.ed ,b1 tJ~h ~o~ . ..!8!'1. ut IL.em of eldJltn& for lM pu~ or '-ol&l-I lht pre.-un tc:.t &.pp&nlua t.o L.ht RIil lo f&.lllnf the wist. When pou.lble, Lht. specUlc < > reqw: rtffl.-'"1'1. •~utre-~ ~ or ~ bod,-from direct. conlA..."1. per.n.lL 1JUIL lnflaUon from • comprea,e-d &lr leU loc:a.Uon aha1J be klenWled ln the tal m~nll of lhla ,lLndud which do not .-tLti a pot.cnUaJI,-hu.ardoua llqukl or ,aae-110c..rce equipped with 111. prcuun lndlc:aUna: tec:orda. Rete.t preaurc. cl.a.La ahul be tt· hllVC a a-cpui.te &tut-up dal..c and ht.,-e oua chcck:a.1'. r-e,-ula.t.e:. The-ka.k llt:hlneu of the. pra-corded u an r.ddJUonaJ luL 354 355 I .. n m I I A-r,J=M1) ·~ B I I I .. I . I I I I I .. I I I .. D I I I I I I .. I I I I I I .. I I MOTEC EMPLOYEE SAFETY COMPLIANCE AGREEMENT Project Number: ______________________ _ Project Title=--------~-------------- I, (print name) have received a copy of the read the plan, safety plan understand for the referenced project. I have it, and agree to comply with all of the health and safety requirements. I understand that I may be prohibited from working on the project for violating any of the requirements. Signed: Signature .Date I I I I I I . I I I I I I .. I I SANDOZ CHEMICALS MT. HOLLY PLANT PROCEDURE NO. Page 1 of. 7 SP-23 SAFETY PROCEDURE: Contractor Safety APPLIES To:· All Contractors and Contractor Personnel Issued: Revised: 2-1-87 New GENERAL When working at the Sandoz Chemical plant site, contractors may be exposed to potential chemical and normal industrial plant hazards. Precautions must be taken to insure the safety of all personnel, equipment and facilities. As a minimum level of safety performance, all contractor personnel will abide by Sandoz Safety Procedures. RESPONSIBILITY The Sandoz Contractor Supervisor and Purchasing Agent are responsible for providing contractors with copies of the Sandoz Safety Procedures and the Contractors Safety Checklist prior to the start of work. The Sandoz Contractor Supervisor shall· monitor the contract work performance to insure compliance with safety rules and procedures. However, the contractor is primarily responsible to insure that their personnel a~e aware of and comply with all safety rules and procedures. PROCEDURE All contractors and contract personnel shall comply ~ith the following Sandoz Safety Procedures. 1. 2. 3. 4. 5 • All contractors shall stop at owner's gate and be directed to the Contractor Supervisor's office upon arrival for the. sta.t of a project. Under no circumstances are a Contractor to start on a project without having been assigned a contact person to coordinate with contractor and represent the owner while the contractor is performing tlle work . Owner's Contractor Supervisor will review work procedures, safety rules, and review all work and procedural matters. He will also assign a ~ontact person if other than himself. Smoking is prohibited in all buildings, yards, and driveway areas, unless specifically allowed as an exception as listed below. Smoking for contractor personnel is limited to designated break areas during scheduled break periods. Properly signed permits must be obtained daily from the contract person and approved by plant operations prior to starting work. Special permits. must be obtained for the following. (See Work Permits Procedure.) a. Welding, burning, cutting or heating with open flame. b. Operation of electrical tools. c. Entering confined spaces. d. Closing or disconnecting valves, pipelines, ~lectrical circuits or sewer drains. e. Use of solvents or flammable materials. f. Entering on the roof of any building. g. Excavating or grading. Parking area and storage areas for materials shall be designated by the contact person. Other areas must net be used unless specific permission. is granted by contact person. • SANDOZ CHEMICALS MT. HOLLY PLANT PROCEDURE NO. Page 2 of 7 SP-23 SAFETY PROCEDURE: Contractor Safety LIES TO: All Contractors and Contractor Issued: 2-1-87 D 6. I 17. • 8. I I 9. I 10. .. 11. I I 12. I I lJ. I 14. I ... I I Personnel Revised: New All areas used by the Contractor and his sub-contractors are to be kept clean and orderly, with free access maintained at all times to roads, aisles, etc. All scrap or trash is to be accumulated and removed on a daily basis, with a complete cleanup at the completion of the project. Final cleanup will be monitored by the contact person. All work shall be performed between the normal working hours of 8:00 AM and 5:00 PM, Monday through Friday, unless special permission is obtained from the Contractor Supervisor to work other hours . All contractor personnel must be clean shaven while working in the Sandoz plant area. Safety glasses and hard hats are required in all manufacturing and construction areas, and plant grounds adjacent to those areas. Safety glasses must be ANSI approved plastic frames and lens. No metal framed glasses of any type will be allowed in the plant area. Safety equipment will be furnished by the Contractor. See Eye Protection, Hard Hats, Respiratory Protection, Protective Clothing and Hearing Protection Procedures. No metal ladders are allowed at the Sandoz plant site. Ladders will be made of wood, fiberglass or other non-conductive materials. See Portable Ladder Procedure. Contractor personnel are entirely responsible for the maintenance and security of their materials and tools. Toois are not to be borrowed from owner's personnel unless approved by Contractor .Supervisor. Machine shop equipment, trucks, fork lifts, crane or other tools owned by owner are not to be used by anyone other than owner 1 s employees unless by special permission, or unless included as part of the contract. There may be times where the use of such tools or equipment will be in the best interest of the owner and contractor. In these cases, permission must be obtained ~hrough the owner's Contractor Supervisor for their use. See Licensing and Vehicle Operation Procedures. Contractor's personnel are expected to receive, sign for, and unload all materials ordered by them or co-signed to them. Materials furnished by the Contractor to owner on cost-plus basis must be received by the owner's agent and this procedure is further described in the contract entitled Contractor Procedures for Cost-Plus Work. All employees of Contractors shall be of age and character commensu~ate wirh Federal andv5tat~ rules and regulations concerning employment in chemical plants. Insurance certificates must be furnished by Contractor and sent to the Sandoz Purchasing Agent prior to beginning work., Shower facilities in change rooms will not be used unless written permission is given, except for emergencies connected with safety. The Contractor is responsible for furnishing bathroom facilities (as required by lai,) when the owner's facilities are not available. See Safety Shower & Eyewash Procedure • All standard and reasonable safety precautions must be exercised at all times. The contractor is responsible for compliance by his employees and his subcontractor's employees with requirements of the Occupational Safety and Health Act, all other applicable Federal, State and local la1<s, rules and regulations. I I I I I I .. I I I I I I .. I I SANDOZ CHEMICALS MT, HOLLY PLANT PROCEDURE NO. Page 3 of 7 SP-23 SAFETY PROCEDURE: Contractor Safety APPLIES TO: All Contractors and Contractor Personnel Issued: Revised: 2-1-87 Ne\-1 16. The contractor shall require each employee and subcontractor employee to read and sign a copy of the Contractor Safety Checklist upon arrival at the Sandoz plant, This checklist will be provided and kept on file at the Contractor Supervisor's office. Under no circumstances will anyone be allowed to perform work unless this form is completed and signed, 17, In order to comply with the OSHA Hazard Communications Standard (29CFR1910,1200), the contractor must submit to our Outside Construction Supervisor, prior to beginning work, information on each ch~mical or chemical material used by the Contractor which will be brought onto Sandez 18. ·Chemicals property. These include but are not limited to paint, solvents, sealers, cleaners, etc. The information to be furnished by the Contractor will include the information required by the Standard for Material Safety Data Sheets (29CFR1910.1200[g]), Sandoz Chemicals will review the information furnished. The contractor will not bring any chemicals onto Sandoz Chemicals property which have not been reviewed pursuant to this procedure. It will also be the Contractor's responsibility to properly dispose of waste chemicals according to the manufacturer's instructions and in compliance with Federal, State and local regulations. No waste chemicals, or waste materials will be disposed of on Sandoz Chemicals property or in the Sandoz·Chemicals sewer system without prior company authorization. The contractor is required to insure that all containers of hazardous chemicals brought onto Sandoz Chemicals property by the contractor are labeled in accordance with the requirements for the Standard (29CFR1910,1200 [f]), . The contractor will have access to a list of the hazardous chemicals to which contractor personnel may be exposed while performing the work on Sandoz Chemicals property together with information concerning the appropriate protective measures in relation to such chemicals. Further Instructions a. Standard electrical voltage at the Sandoz Mt. Holly plant: 110 Volt, 1¢ 220 Volt, 1¢ 550 Volt, 3¢ b. Owner's supply house will not furnish or sell materials or supplies to Contractors unless it is included as part of the contract. c. Contractor visitors will not be allowed to enter the •plant unless approval is given by the Contractor Supervisor or his representative. d. Exceptions: Any contractor desiring exception or exclusion to any safety requirement/procedure must submit the request in writing to the Safety Manager, Exceptions must be approved by the Safety Manager and Maintenance/Construction Superintendent, and be prominently posted in the concerned area . e. All accidents, injuries, work-related illness, fires, spills, ar.d other incidents regarding safety or loss of property or materials whether actual or potential are to be reported immediately to the Contractor Supervisor. Contractor Supervisor will inform the Safety Manager and other appropriate management. n u. D D D I I .. I I I I I I I SANDOZ CHEMICALS MT. HOLLY PLANT SAFETY PROCEDURE: Contractor Safety APPLIES TO: All Contractors and Contractor Personnel PROCEDURE NO. Page 4 of 7 Issued: 2-1-87 SP-23 Revised: New _ _;;="------ This requirement in no way relieves Contractors of their obligation under the law of reporting requirements by OSHA and other regulatory agencies. ~G~ SAFETYMANA¥R < ~ PLANT MANAGER I I I I .. I I I I I I .. I I United States Departn1ent of the Interior FISH AND WILDLIFE SERVICE Division of Ea:llogical Services P.O. &l>{ 25039 Raleigh, North Carolina 27611-5039 Ms. Giezelle S. Be'l!lett U. s. Environrrental Prote:::t.ion Agency 345 Ccurtland Street Atlanta, Georgia 30365 Dear Ms. Bennett: Septanl::er 16, 1987 'lbe U.S. Fish and Wildlife service has reviewed the draft Record of Decision for the Sodyeco Site in Charlotte, N:i::th Carolina, ciated Septernl:er 4, 1987. 'lne Service ·con=s with the recommended r ernedy, Al terna ti ve 9, for remediation of groundwater and soil contamination. Sincerely yours, -~;d, ~ ?o.c.u.~ David H. Rackley Acting Field Supervisor I I I I I I I I I have read and fully understand the safety rules and procedures listed on the Contractors Safety Checklist. I also understand that this is a general list of safety rules and other safety rules and procedures as may be required. SIGNATURE: DATE: CONTRACTOR: ______________ _ I I I I I I .. I I I I I I I APPENDIX I CONTRACTOR SAFETY CHECK LIST Contractors are required to follow all OSHA and other Federal, State and local laws, rules and guidelines, and Sandoz safety procedures. 1. Safety Permits 2. 3. 4. A. Contractors must have safety work permits signed by contact person and appropriate Production Supervisor before starting work. B. Special permits are required for the following: 1. Burning, welding 2. Using power tools 3. Entering on roofs 4. Entering confined spaces (lock out procedures) 5. Breaking or disconnecting pipelines (lock out procedures) 6. Excavations, trenching Hard Hats/Eye Protection A. Hard hats shall be worn at all times while in the plant area. B. Safety glasses shall be worn in all plants, shop, warehouses, farm or while performing construction/maintenance type work. types of eye protection may be required when necessary. Foot Protection tank Other A • Steel-toed safety maintenance work. Sandoz plant will shoes are required for any type construction/ Anyone performing other types of work at the wear leather type shoes. Restricted Areas A. Contractors shall sign in or check with appropriate private area supervisor before entering the following areas: (See Restricted Areas Procedure) 1. Effluent Area 2. Any Production Building 3. Tank Farms Contractor personnel must stay in assigned work areas. 5. Smoking A. No smoking except in authorized areas. below: Designated areas are listed 1. Breakhouses while on scheduled breaks. 2. Contractor facilities located near rear gate. 6. Food A. No food or drink will be allowed in any production plants, warehouses, cank farms or effluent area. All eating will be in breakhouse or designated break areas. B. Drink water from water fountains only. 7. Working from Ladders and Scaffolding A. All contractors are required to follow OSHA standard subpart Ll926.450, 1926.451, 1910.21, 1910.2B, 1910.29 .. I •• I I I I I I I .. I I I I I I .. I I 8. 9. B. No metal ladders shall be used at the Sandoz plant site. Ladders shall be made of wood, fiberglass or other non-conductive materials . Special Safety Equipment A. When working in confined spaces, or breaking and pipelines, special safety equipment is required. Lockout and Confined Space Entry Procedures. entering See Equipment. 1. Confined Spaces a. ·Breathing air supplied respirators b. Air blower c. Safety harness and rope d. Ladder e. Explosion meter f. H2S meter g. Alarm horn h. Watch person i. Lock out procedures 2. Breaking and Entering Pipelines. See Unplugging, Disconnecting, Removing Pipelines Procedure. a. Protective clothing b. Face shield, goggles c. Lockout procedures Burning/Welding Open Flame or Using Flammable Liquids. Permits Procedure. A. Special Permits Required See Work B. Fire Extinguishers Required C. For burning and welding, watcher required except in shop environment. 10. Excavation and Trenching A. All excavation of a depth of 5' or more shall be sloped or shored ·according to OSHA standards as stated in 29CFR 1926.651 and 29 CFR 1926.652. B. There are no exceptions to these standards. C. Permit required. 11. Emergency Whistles A. B. C. While working at this site you should be aware of o:.ir ernergnncy warning system. While working in production plants you should always be familiar with the location of all exits. Anytime you hear a loud whistle of more than one blast you should report to the Contractor Super-visor 1 s officeTmmediately. Below are the normal times that you will hear a whistle. Start Work Start Lunch Stop Lunch Quit Work 8:00 AM -12:00 PM l: 00 PM 5:00 PM I I ,. I I I I I I .. I I I I I I I r9 I The Site Safety Officer in concert with the Project Manager shall be responsible for deciding if respirator use is required. Total organic vapor concentrations shall be monitored using an HNu Model PI-101 organic vapor analyzer with a 10.2 or 11.7 eV probe calibrated to benzene. An air purifying respirator shall be required. for any activity, intrusive or nonintrusive in which significant amounts of dust are generated, or organic vapor concentrations in the breathing zone exceed 10 ppm above background for an average of five minutes, or where a potential for significant exposure via inhalation exists. A half-face respirator with total organic organic vapor/HEPA cartridges may be worn at vapor concentrations up to 100 ppm. At concentrations from 100 ppm to 250 ppm in the breathing zone, a full-face respirator with organic vapor/HEPA cartridges will be worn. At breathing zone concentrations of 250 ppm or above, all work shall cease and workers in the exlusion zone shall exit that area. Employees will not re-enter the exclusion zone until the situation and levels of protection are evaluated and the ambient organic vapor HNu readings fall below the appropriate action levels. Cartridges in air purifying respirators will be replaced after daily use, when damaged, or at the first indication of breakthrough. If odors are noted while respirators are in use, work shall cease and protective equipment will be inspected and repaired or replaced and the situation, including levels of personal protection, will be evaluated. At no time shall individuals use damaged or nonfunctional respirators. is used as the action level level of 10 ppm of potentially An organic vapor for indication Individuals may choose to upgrade hazardous organic to a half-face or vapors. fullface respirator inhalation shall make at ambient concentrations of organic vapors becomes every effort to minimize 35 below the a nuisance. exposures action level if All personnel by positioning I •• I I I I I I I .. I I I I I I \a I I themselves upwind of dust and vapor emissions . Respirator use may be terminated if continuous organic vapor measurements drop to background levels for a period of 15 minutes and no dust is being generated. Air quality monitoring data shall be recorded at regular intervals. in Attachment G. An air monitoring data sheet is provided Disposable coveralls and hoods shall be reinforced with duct tape in areas that are prone to tearing. All protective equipment, such as coveralls shall be replaced at the first indication of being torn or excessively soiled. The SSO and PM shall have appropriate personal protective equipment readily available for upgrade, replacement or rescue of site workers. 7.5 EXPOSURE MONITORING REQUIREMENTS Ambient organic vapor monitoring using the HNu will be continued until confidence in "no exposure possible" is obtained, or the project is complete. 7.6 DECONTAMINATION PROCEDURES Personnel will not be permitted to leave the exclusion zone/decontamination area unless contamination reduction area will properly be used decontaminated. A to control personnel access into and out of these restricted work zones during any associated activity. Basic described in Attachment E, decontamination procedures, will be implemented within as the contamination reduction area for activities conducted within the exclusion zone or for intrusive work activities. 7.7 HEAT STRESS MONITORING Heat stress symptoms (e.g., ness) will be monitored by the excessive sweating, light Site Safety Officer or his periodically and measures taken to reduce heat stress headed- designee if this 36 I I f I I I I I I It I I I I I I I t' I is observed to be a potential health and safety hazard for workers wearing Saranex or Tyvek coveralls. include the following: Actions which may be taken * Provide plenty of liquids (water and/or Gatorade) * Wearing an undergarment that acts to help body ventilation (preferably cotton clothing) * Provide showers or hose-down facilities * Scheduling of activities during cooler hours of the day * Provide sun shade over work area * Rotation of worker shifts * Monitor pulse rates prior to each rest period. The pulse rate should not exceed 110 beats per minute or work period should be decreased by 33%. * Employees should be weighed in at the beginning of each shift and prior to each rest period. Workers body weight loss should not exceed 1.5%. If it exceeds 1.5%, workers should be encouraged to replace with fluids the amount of body weight lost. 37 I I " I I I I I I ll I I I I I I I r I 8.0 EMERGENCY RESPONSE 8.1 PHYSICAL INJURY In the event of an accident resulting in physical injury, apply first aid and either call an ambulance or transport the injured individual to hospital. A physician's attention is mandatory regardless of how serious the injury appears. 8.2 FIRE, EXPLOSION, AND PROPERTY DAMAGE In the event of a fire, explosion or on-site Sandoz officials immediately. damage to property, notify If Sandoz officials are unavailable and the incident requires assistance by local fire or police department, contact the appropriate department by telephone. An arrangement with on-site Sandoz management must be made to have a telephone available for use by project personnel at all times. 8.3 EMERGENCY TELEPHONE NUMBERS Fire Department Police Ambulance Hospital Utilities Internal Emergency 228 Outside -Mecklenburg county dispatcher 336-333.3 Same as Fire Department Same as Fire Department Presbyterian Company equipment supplies utilities 38 I I r9 I I I I I I II I I I I I I I f I 9.0 PROJECT PERSONNEL The personnel assigned to this project field activity include: Project Manager: John Bogart Field Personnel: Gerald Summey 39 __ ,,,,,_ f 1t10.1J9 ------· 2t CF1 0.. XVI (7-1..V lofltlon) • Comp,-Ou Aaoclatlan. Inc.. IOO Plllh of lhe Code of Federal Rqulallollll A1'"1UC. New Tort.. KY IOOJI. apply pursuant to lhelr Lemu lo haz.-Amcrican Socktp of Necta.nk::aJ F.ncmttn ardoua •a.ate opera.tlon!i <whether cov-lnc .. Unlt,,d l:nsln<,,r1n, C.nter. H6 Eut -• b lh'-I I ·'di •nth Btnd.. ""' York NT l0011 en:-u 1 Ml acct on or noU. n -.u -American Pl'lrolnlm irwt.JtuU, · IIGl It lion the provi.alona of thla aecllon SLr-ttl. NW .. Wuhlnston, DC ,oooe_ &WIJ to operaUon1 covered by thta Na.Uona.l Board of BolleT and PnNutt aect.ton. If there la a connlct or over-Vcael l,w;pect.on. I lH Marth Rish SLrttl. lap, the provillon more protective or Columbia. OH 41201. employee a.fety and health ahall "';:.~~'::!. ~ 1.::;::itute. WPIJ: 211 CFR 1810.&<cl<ll la nol appli-Amtrk:an 8odetr for ~llna and 1i1uerta1a/'cable ... IABTNl. 1111 Raco Bln<I. Phlladdphla, )U) All_-. hi of lhla aecllon PA 11101. /1/Sc,epl~h lol WPIJ lo hazard-Ondcnn1Len' l&hon.Lorle&. Inc. CUL)~ oua e1.i~ raponae operations w:..t Ohio lllnel. Chlcqo. IL IOIII. under CER major correctl,e OC• Pcrt.lllaer lnst.lt..u~ 1011 11th 81.rttt ,.. Uom tak~~ln clean-up operaUone Waahlnc""'-DC --/ / under R -,wmeraency re--lH PR DII02. lune n. 111', u ~ a& -QPe """· and huantoua to I'll 1100. April JI. Intl '-._ "-. ..-..Le op,iratfoiw thal-huei>een deals-I . uale<I .tor jlean:up ,-i>Jst&le.'i!r local ~ 1111.tn H.......... ,.... -·atk.,:o--J iro•emmmtal. _aull\Qrl.Uea. -.....,__ \ .., cwwwafea..7 •w; . -(Ul)·Only \he requjremen~Jtf),an. ------Oca,paflonal l<,hty end H..tlh Ado.tin., .___ -.--f 1910.12' an uncontrolled re1eue of a hua.rdoua (ii) any blototic .,..ent and othu di.! 1ube:t.ance. Reaponaes to lncldcnt.&l re-eue a.wins &l"Cnt u: deflncd In ae< 1 ..... lhat can be abeorbed, neulral-lion 101133) or CERCLA. lr.cd. or olhenvlae conlroUed al lhe 11111 any aubol.ance llat.ed by lhe U.E lime of releue by employeea ln the Department of Trarul;portatlon an, Immediate relcaae area lln'! not conatd-resulat..ed aa huardows material e~ lo be eme,..ency reepo,-within under 49 CFR 112.101 and appendlcc, lhe ■cope of lhl■ ■t&ndard. Reaponaes and lo releuee of hu.ardoua subatanoeo 11Yl huardoua ..-..Le. where the conocntntlon-of huardoua .. Htut1ntovl v:,,a.aU" mea.na (I) a wut.i ,rubolance la below lhe ..rtabll■hed per-or comblnaUon of wuu. u clerlncd II rnlaalble e•poaure llmtla att not con-fO CFR 281.1, or (U> thoee subel.&nce ■Ide~ lo be emerscncJ re.po,-. clellned In 49 CFR 111.1. '0E114bl~ pennlulW., czpon."' HruClrd<nu IO<UU opn-allon" mean Umft." 1:nea.na the lnhalaUon or dermal IU'lJ' opera.Lion lnYolrlnc empto7ee ea permlalble cxpooure limit apedned In powre lo huantow wut.ea. hazardow 211 CFR ~ UIO, Bu~ z. or U iJUbatancea. or &nJ comblnallon or haz none la ■i>edfled lhe npooure Umlla In anlow wu1.ea and hu.&rdoua ■ub ••JnOE!H Reoommendallon■ for Oocu-litances lh&l att conduct.ed within lh• pallonal Beallh 81.andarda" daud Sci>-■cope of lhl■ nandard. lembcr 111111 lncorpon.ud by refer-"Hazard<nu -..u riu" or "•lu' ence. or' U neither of the abo,e II spec. mean.a &n7 facUltJ or locaUon &I Uled. lhe ■t&nclarda ■pecl!lcd b7 lhe which huardoua wut.e operal10111 la) ~leaf~ •"4 ~,.,_ rni,h (ol ~ ,,p&rqraph Ill of; lhla uom..::nr Th oedlon lircri oecUon OPl>IJ },o lhoee opcn.lloria In• cmp1oJen and emploJea c~ In .-olrtnr ~ua wut.e lilon.ae, dla-lhc lollawlnc c,pen.llons: _._ and_ \tt&lmenl fad!lllee rccul•t.-:;; Ill Huantoua ,rubatance ns;,c,nae DP-ed under 40 CFR Part. :2114 and 215, erattona under the ComprehenalYe DI· es.ccpt for am.all quanUty ceneralora / ... 1 . t1ronmmtal ReoPonoe, Compenaallon, and lhc.. emplo,en;w1lh leu lhan1HI // and UabllllJ Acl or 19110 &.:i amended da,-a accumulallon' .. dr hazan:101111 American Conference of Oo-..mmcn-within lhe ■cope of lhla ■t&ndud I.a.Ir.I la! lnd1111t.rla.l Hn1enl■ll In lhelr pubU-pia<,e. cation '"Jlt,...hold Umll Value■ and "HeaJlh A<uanl" mean■ a chemical Bloloe1<:al Exposure lndlceo for UM-mb:lure of chemlc&la or a path01cn 81" daud 1900 lncorpon.ud bJ' refer-for which lhere la alallallcallJ ■lcnlrl­ence • .or U none of the aboTe II aped. cant evidence bued on at leut ont fled.' a 'llmll bued upon a publLlhed ■ludJ conduct.ed In accordance wllh ee-lludJ .or ·manul&Cturen' afelJ data labllahcd ■cienllflc prtnclpl.. lhal aheet brouahl t.o the employer'■ att.en-acute or chronic health effecla ma.J 142 UB.C. PBOI el aeql ICl:RCLAl, In-wulel aa defined In 40 CP'R 282.J,.. ......___ // cludln& , lnlUal 1n .. sUpllono al <I•> f'arauaph Ill of lhla "aecllon ap. •· CERCLA ■It.es before the preaence or pllee t.o emeraency rupo08e opcr:---/ /' kbaenct: of huardoua aubst..a.noe:I hu a.tlona for nleuea of or aubst&ntlal been uoert.alned; lhreala or releuea of hazardoua 1ub-/ 111 l Major corr,clln actlone I.a.Ir.en In al.&ncea. clean-up c,pen.Uon1 under I.he Re-Ill D,/lKllk>N-"B-.44• ..,,Inn" ,. 1 aource ConaerT&llon and RecoYer, Act meana • system of orp.ntr.Jn, employ. .. of 11171 u amended 142 UB.C. IIIOl el ..,. Into won. sroupe In such a manner aeq) <RCRAt, I.hat each emploJee of lhe won. sroup IUU _Operallona lnrolt1nr huardoua lo dcslpaud lo obseTTe lhe actJvlllee wut.e stora.ce, dia:poga.J and treat.ment of al tea.al one other emplorre In the facllltleo ~l•ud under to CFR won sroup. The purpooe or lhe buddJ Part. M4 and 285 pursuant lo RCRA. ■,-at.em la lo prot1cle quiet usu,lance lo except for small quLlltllJ reneralora thoee other employees In the event of &.nd thoee employer.-wllh lean than tO an emersency. daJ"I a.c:cumulallon of hu.a.rdoua •·.t>econ.tamh1e1Uofl"' mean& the re. wulel u <kllncd In 40 CYR 282.14; moval or hau.rdoua ,rubotanoeo from (ly) Han.rdow wuLe o~n.llona .tt.ee employees and their equipment to the thd haTe IJiecn dealcnat.ed for clean-up e:.tent nec:ea.t.rJ &.o preclude the OC• b7 &tat.e or local 1ovemment.&l au-currenoe of foreaeeable &dvcrae healt.h lhorlllca; and eUecla. (Y) Emcr&COCJ respon,e operaUons •·z~ rup,onu•• me&ne a co-for .r-ele-uea of or lub6L&.nUD.l th~ll of ordlnat.ed r-esponae effort by employ-~leuea: of haurdoua aubsla.nct:1 and tta from ouUldc the tmmedlale re-posl~merc-cncf reaponae op,cntlona )cue area or by oul81dc ret1pondera !or guch rclcucs. <I.e .• mutual .aid groupg, local fire de-(2) AwttcaCion. (I) AH re-::aulremenll pa..rt.ment.&, etc.) lo an oa:urnncc or ~rl 1910 u,d P>.rl 1920 ol Tille 211 .-hlch rcaulle, or la lltely lo rceull, In 340 ,tloa'The two document.■ lncorporated occur In e1:poeed emplo1eea. The Urn, /by 'referencc·~--are avall&ble for pur-"health bu.a.rd" lncludea chemical.I / chuc from the foUC:nrtn,: which an carclnoecna, lode or hl1hl) 1 -NIDBH / Publlcallon11 Dlaemln&Uoa. lode &&enla, reproducllve loxlna. lrrl I/ / DMal~n of 8t.andud■ Dnelopmenl I.an!&. corroalvea, ■enalllzen, hepalo ~ / and TechnolOll' Tn.nlfer. NtJ.lonal t.ol:lna, nephroto:ilna, neurotoxlns v Inalll.ule for OocupaUonal &felJ ....,,La which a.cl on lhe hemr.lop0letl< and Heallh 48'11 Columbl■ Park..., 1,-at.em. and ■..enla which damaac lh< Clnclnnatl.'OH 45221, <5111141--428-i"· .. lunp, ■tin. e1ea. or mucoua mem-Amerlcan Conference of Oovemmcn-: brans. Pu.rt.her dcflnltlon of tht w Indualrl&l Hn1enlala. l!IOO Olen• Lerma med ~bove can be found In AP-way A-.. Bulldlna D-7 Cincinnati. pendlI A lo 211 CFR 1910.1200. OH 4521i-44JB UUI tNll-11111 "'IDLH" or ••/mmedklld• dan~w • ' · . to Ult: or ~th" rnea.na any almoe;-and are anllable for inape,clJon and pherlc condition lh&t poeco an lmmcdl-cop,-ln& at lhe OSHA Dockel Orllce, ale thr-c&I lo life, or which I■ likely to Docket No. 8--780, Room N-J871, 200 reeull In acule or lmmedlale ""•ere CoNUlullon Ave., NW .• Wuh~n. health effect.■. Thia lncludel oxygen DC 30210. deflclenc, condlllollll. .. Haza rdov.a nb,ta PlCe.. mea.na an, "'/rn m.ed«J tt: U1:>t:re health (ffect, •• subrt.a.nce desianated or lilted under mtt.n1 any acute clinical ■Im or 1ymp-(l) lhrouah Uv> below, e:1P<)IJUtt &.o tom of a 1er10111, expoeure-relAt.cd re-which rc1ult.a or may result ln a.dvene a.ctlon manlfcst.K within '12 hours ,ttecu on the heLllh or aaJet1 of cm-a.ft.er e1:poeure to a har.ardous aub-plorees: at.a.nee. Ill anJ ■ubrta.nce defined under oec-••0rwrn ~ .. mearu lhal con• tlon 101<14) of CERCLA. cent.ration of oxy1en by volume below 341 --r --llill == I!!!!!! -'I --- -- --.--f 1910.120 tt en a.. xvn 11-1-11 Elffllonl whkh air aupplylnlt regplralo17 pro-Cl> E,wlnttrlno conlroll, ,oorlt pn,c-Lectlon must be provided. IL e:a:Lsta ln ti.cu an.d penoncl protecUve equ.ip-atmospheres when: the percent.ace of menL Enrtnecrtna control.a, won. pr&e-ox11en by •olume la leaa than UL& per-Ucea, pcraona.1 prot.ec:tlve equipment. cent o:a:rsen. or a comblnatlon or theae aha.II be lm-""Slu 14/elf cnd ~IA ont«r" plemcnt.ed In accordance wllh pua-mcana lb• lndlrldual localed on a hu,-_.nph 11> ol lhla occtlon lo prolecl em• ardom wutc alt.e who la reaponalble to ployeee from exposure to haz.a.rdoua the employer and hu lb• aulhorllJ oubot&nces and health bar.&rda. and lnowledae ue orJ lo lmple-/,·-.(1) Jlonllorinp. Monllorln1 ohall be menL lhe oil< ao!elJ and beallh plan performed In att0rdanc< wlLh para-and nrllJ compll&nee wllh appllc&ble ~h ·>(h) of lhla oecUon lo ...,.un, ao!elJ and beallh roqulremenla. / proper oelecUon of ens:tneerlnlt eon-fbl ~ '!V!'fmn,-nt,--(1) 6a/<f, troll, •('rt. pracllcea and peraorw pro-aadj,rogram.. E&Ch employer Lecth·e '-;Qulpmenl ao that employees ah&ll d,ttlop and Implement ,., alolJ are nol npi,oed lo lnela which exceed and health prosn,n for Ill emplc,j... ..ablloh/,d I pe,;n~lble upooun, lnYOl .. d In huardoUI wairte -'.pper-llmllo for h~!"'-' 1ubolanca. al.lono. The p,-osrun. u a rnlnlmwn. 11) l~orJ""!l~..41,9!"V"'!'."-EmploJ• ■hall Incorporate lhe roquln,menlo of eeo. oont.n:clofll. an6 oubeonlraclon or lhla oecllon and be pM>Tlded. u &PPl1>:: --U.elr npreoenlaUve ■hall -b!e lnlonned prl&le, lo &nl' aubeontraclor or Ill ~ ._r lhe clesne and ualun, ol ao!e~J and te1Cnlal1TO who will be lnYDl•ed w!l.h heallh h~ J,pedflc lo ,lhe work the huardolll wute uperallon. The alte bJ _.mini" lhe. ,u.lrlJ .-and 1heallh prosn,n aha!! be deslsned lo ldenUIJ, =looµtl'.r" In ~h _!I> of lhla ,, I ,.aJuate, and eonlrol AlelJ and It> "ir" uriGZ "'2"411 r Buanloua /.,,. 1/ h~lh huarda and prorlde for emer• " . AQ. ., , ireOCJ rewonae for haZl-rdouo .....i,, subot.ancea and eonlamlnaled oolla, Uq-/ I operallona. · uld&. and olher n,aldueo ■hall be .h:u>·/' / n> Siu c"'2rc,clninttml •"" a1141r-died. lralwPOned. 1..1'-l"'led. and ~ / poeed of In accordance wllh -h OU. Rsmrdoua wule &!lei ohall be (J> ol lhla oecllon. < / '-, '-, I nalualed In aoeord&nce wllh para• CID> Deconl4ml"41io!L '•l'ro<,edui,,o · Cr&Ph (c) of lhla oecllon lo ldenWJ for all phues ol c!ea>nlamlnallon ', / opecl!lc &Ile hau.nla and lo determine &ho.II be developed and lmplemenLed In I / lhe appropriate ao!elJ and health con• acconl&n<:e wilh pa.r&&nPh <kl of lhll/ , , / lrol pr<>ee<lura needed lo prot.ed em• o,ec:llon. I.__ . ploJeeo from lhe ldenUlled huu-da. fill _r;~ 1ffJ10JUC. Emerirencl' ,_ / (II SIU conlrol. Bile oonlrol prooe-n,apouoe lo h..-doua wule operation· ctun,o ohall be lmplemrnled In aocord· tncldenll oho.II be conduct.ed In accord· L"lce w!Lh -h (d> of lhll oecllon u,ce with pa.rav-aph Cl I ol thla aec• belon, clean-up work bet'lno lo control uon. I / ·> .. ,/ emploree upooure lo lw:&rdouo aub-<Ul m•ml"""""-Areal acoesalble r-. lo emploJeeo ■hall be llrhLed In M:· 10 T>-ulnl"II. Initial o,-refrsher or eord&noe wlLh lhe roqulremenLa of n,rlew Lnlnlnlt meellnlt lhe require-p&n&",~h (ml of lhll oecllon. menu ol po.n.&r&Ph (e) of lhla oecllon (UI Scn!tal!mL P'acllllleo for em· ohall be provided lo £rnplo1eeo belorc ploye,, aorulallon ohall be prorlded In lheJ ue pennllled lo onr-In ha.t·. o.oeord&noe wllh -h <n> ol lhll ardouo wule oper-.Uono lhal could oeellon. e1pc« them to ha.urdoua ■ubrlance&. (14) Sile acaOG.tf.ot!!.. Bite csCS:va-oaleLJ. or health har.&rda. Uono created durlnlt Initial slle pn,p&• (I) Jtcdlcal n,rvdlloJI.Ce. Medical n.tlon or durtn1 ha.urdow wa.ate o~r-suneU1a.nee ah&ll be provided tn a.c-atlona ahUI be ■hored or aloped to pre-conia.nce wtlh pa.n.cn.Ph <O of Lhla ,ent accident.al collapee and conducted 9K:Uon for employeea e1.poecd or po-ln acoordUloc with Subpart P of 28 lenllallJ upooed lo huardoua 1ub-CYR Part I 828. at..Lnces or hca.lth hu.&.rda or who wear (lf,) Controcton and-n,b-contrac-reaptr-aLors. ton. An employer who rdaJN conlrac-3(2 Ouupo-t1ona1 Safety eild Health A,hwln., I.ab« t 1910.12 tor or sub-contractor .ervlces for wort In hu.a.rdow wut.e operatlona aha11 lnfonn lhoee contract.on:, 1ub-conlrac-tor-a, or lhr:lr rrpr-car:ntallvea or any poLenllal fire. ei:ploelon, heaJth or other .. rety har.a.rda or t.he haz.a.rdoua •ut.e operation that have been ldr:nt.1-rled by the employer. tcJ Sttr charocffickattoo •~ an~r-W.. (I> A prellm ~arf evaluaTon D & alt.e's charact.ertallca ■hall l>e-per-formed prior to ■lt.e entry by a t.ratned penon lo aid In lhe .. 1ecllon ol appro-priate employee protect.Ion method& prior lo oil< entry. Durln1 site enlry, a more detalted evaluation or the ■tLe'a opecllk cho.racterlalko ohall be per-formed by a Lralned penon lo further ldenllly nlotlnlt 11\e hu:arda and lo further aid In lhe .. 1ecllon ol Uie 11.1>-proprlale nllin«rlnl conlrola and penonal protective equipment for the lallr.a lo be performed. <2> All IUlpecLed condlUono that maJ -Inhalation or akin &baorp-llon hu:arda Uial an, lmmedla\elJ danlerouo lo IUe or health <IDLH) or other condJU01111 that may cauae death or aertoua ha.rm ahall be ldenllfled durlnlt -.. lhe prcllmlnu-,, ourvey and •valuated durlnlt lhe delalled aurveJ. !:xunplea of ouch hu:arda Include, bul ~'are' not ·1tm1Led to, confined si-ce ' enUT, pot.ent1a.U1. exploel•e or nun-m•ble •lluoUona, Ylllble ,apor doud&, ·or· -..reM where blok>(k:a.J lnd.Jcatora 1uch ai dead a.ntma.la or •ea-etallon are locat.ed. . '· . . <3 > The lollowlnl lnformaUon 1o lhe exlenl .. allable ■hall be oblalned by the employer prior lo , .ilowlnc _em ployees to enter a alt.e: / · (I) Location and approxbnate me of lhe &Ile. (II> o..crtptlon of ther-esponoe acth-ilJ and/or lh• Job . t.ut lo be per-formed. ' · (JIil Dur-.Uon of lhe planned em• ployee actlrllJ. llv> Bile loposraphJ'. <•> Bile ■-=lblllly by alr and ro&da. Ml PathWIJI for h....-.udoua aub ou.nc,, dt.penlon. (YII) Present 1lalw and capablllll of emeraency r-caponae t.eama l would provide aaalat..ance t.o on•alt.e e pJoyeea al the lime of a.n emr:r1ency. 1--· (viii) Hu.a.rdoua 11ubel&ncea an health haz.ards lnvolve-d or expect.ed I the alt..e and their chemical and phys cal properties. <4> Prraonal protective equlpmer. CPPE) ahall br: provided and we duri.na lnJllaJ alt..e entry In accordanc with the followln1 ~ulremenla: <U Baaed upon the result.a or the pn Umlnary ■lte ewaluaUon. an enaembl of PPE ohall be aelecled and uae durln1 Initial oil< enlry which wlll prc vlde prot.ectlon to a level of exposur below eolabllohed pennlaalble e•P< au.re llmJla for known or auapecle huardouo aubalanceo and heallh ha, ardll and wlll provide prolectlo1 .,...J.nat other known and auapect.e, huanla ldenllfled durlnlt lhe prellml nary alle evll.luallon. 1111 An eocape aelf-conlalned bn,ath Ins apparatua ol al leul five minute duration ahall be can1ed by employee or kept av■Jlable at. their lmmedlat. wort at.a.lion U pmltlve-pressu~ aeU conlalned bn,athlnlt appanlua la no uaed u part of lhe ent.ry enoemble. (111) II lhe pn,llmlnar, oil< evalua tlon doN not produce autrldmt lnfor m.aUon t.o ldenUfy the ha.r.&rdil or aw peeled haJ:arda of the ■lt.e an enacmbl1 of Level B PPE ohall be provided ,. rntnlmum prot..ectlon and dlreci. read Ins lnalrument& ohall be curled lo ldentllylna IDLR condltlona. !Bee Ap pendb B for 1Uldellnea on Lenl I prot.ectlve equipment.) (ly) Once lhe ho.z&rdl of lhe 1ltA have been poelllvely ldr:ntUled, the a.p proprl&le PPE ohall be aelected anc uaed In accordance wllh panaraph <1 of Lhla oecllon. <D> The loUowln& monllorlnlt ohall be conducted durlnlt oil< ent.ry when the alt.e enlua.Uon produca informa-tion which ahow the potential for Ion• b:1ns n.dtallon or IDLH condlllona, 01 when the alt.e lnfonnallon la not auffl-clenl to rule out these p,osalbJe condl· Uona:: (I> lolonllorlnlt for huanloua levell of lonh!n1 n.d..111.tlon. CU> Monllorlnlt the air wl!h appro prtal.e teat equipment for 1D1.Ji a..nC other condltlon1 that may caua-e dealt: or e-er1ot.:..11 ha.rm (combwtlble or explo elvr: almoepherca, oxy1r:n ddklency t.oi:lc aubela.ncca.) (3 1111111 mm I ;·110.t:zo r I!!!!!! !!!!!!!! -- -n u:t o.. 11...-u (7-1..-1 Edition) -<till Vbualt, observe for alma of Ul> Safety. hea.llh and other haarda w Occupatlona, f.i.rflll He-d ... -1---~10.1 .. actual or pot.cnlla.1 IDLH or other da.n-prt::a-enl on t.hc alt.e; 1eroW1 condition.a. <Ill> Use of PPE; (8) Once lhe pn::a.ence and concen-<Iv) Work pra.cllces by which lht cm-lrallons of apeclflc haz.a.rdow aub-ployee can minimize: rlslul from haz-11..a.necs and hca.llh haz.ardl. have been ants; establlahed, the mu U;aOClat..cd with <v> &re ~ of cnalneerin1 conlrola lhea-e aubst&ncu ■ha.II be Identified. a.nd equipment on the alt.e; Employe-ea who will be worktn1 on the lvl> Medical aurvclllanc::e requlre-alt..e ahl.11 be lnfonned of any riaU that mcnt.a tncludln« ttcOi'Jllllon of aymp-havc been kSentlUed. t.onu: a.nd 1l.-ns which ml1ht tndlc.at.e hOt Uml~ Lo: 011l PaJ-unpha (0) lhrou1h !Kl of "on: Rl&.u \.o ODNJder lhclude, but an;;;·ver exposure t.o ha:r.arda; and J:apcouru .. .,_,.,,, I.he aw,oprtat< lbe .it.e eaf~ly and h<&llh plan ael Thnshold Umll. Values. rn.Val. Penn•tbl1/:0rth tn ~h (1)(2)(1) of thlll ae-c-l:•pc,1;urt UrnlLI CPEIA,. or R,:cornrne~ Lion. ~ ~ D~un Um.ILi l~l. · !DUI """°'nt,atlo..._ / 12 l All em lo eea •~I o.l the lime of l'<>knlJ&I &In A""°""""' ond;:s:lk>n .lob .... i.nm nl rtte!•e'a.mlnlmum of Sou,..._ 40 houn of lr)lllo.t ,lnalrucllon oll lhe Pol<nlJ&I E>-• lrrlt&Uon lloun,eo. alle, o.nd o. m!nlmUJu ¢ tte-d&ya of J:aploolon ll<nalUrltr ond ~uo.l~eld' experience ~er lhe Ranae&. '-......_ direct. a-µt;,erniito'n or" a lnJned.,exS>ert-11) ~ lnlonnallon concemlns lhe eneed liupe~r. )"!'or'&en who ~o.~ be chemical, phyalcal, o.nd loxlcoloti\c npoeed lo )l,lll11ue 11r apcclo.l. hu.arda properties of ea.ch subol&nce ltnown or •ho.11 be PT"vl<jed o.ddlUono.l lra.lnln&. upocled lo be p,-nl on alle lho.l II The level .()f ln.inlnc PJ:'f'rided aho.11 be &v&ilable 1.0 the emplo7er and relevant. consU:tent ~Lh the. emp_loJee'■ )ob4· lo lhe dullea an employee II expected !unction a.nd n,,ponalbllllleo. · lo perlonn •ho.II be mMle o.voJIILble lo Ul On.-lle ~emenl /u>d aupen1/M all tmployeea prior to Lhe commence-aora d1rect.lr responalb~"e: f~ or who 111-menl of lhelr wort &ci.h·tt.lea. peni.e emplo)'eea efll"l.a"ed ln bu.ard-CI> An oncolna: Uf monllorfna pro-oua •a.ate opera.Uona ■hall -~ recet.e ,rra.m In o.ccordance wllh puavaph lrainlns .. provided In j,o.n&,-aph ---...._ lh) o! lhla oecllon ahall be lmplemenl.-(e)(ll o.nd le)(2) of lhlr oecllon o.nd al ', ed alter alle ch..,..,,lerlullon hu de· leut •llhl o.ddlllono.l houn of apecloJ-I lermlned lhe alle Ir aaJe for lhe .tLart--lud tralnlna on manq\na such oper-/ up of operaUona. aUona al \he tlme or job ualpunent. ; ldl Sf~ control. Ill A &Ile conuol 141 Tnlnen aha.II hue ..-1,ed a 'v p~ or prnenllna conto.mlruLllon le,el of ln.lnlna hllher lho.n and In-of emploreea 1h.U be deYelopcd eludlns lhe 1ub.lecl ma.Lt.er of lhe level durtns lhe plo.nnlns lll4ca of .. hu, of lnalrucllon lho.l lheJ ..... provldlna:. U"doua •ute operation clean-up. <&) Employea ■bAll not pa.rtlclpate 12) The alle control provu,, oho.II, u In field o.ctlvllleo unW lheJ ho.ye been o. minimum, Include: A alle ma;,; alt.! tnJned lo o. Jeni required bJ lhelr )ob worll. Mln<a; lhe uoe of a .. buddJ !unction a.nd ,eop0nalbllllJ. 1y1Lem"; ■Ile communlc&Uona; lhe 18) Employees and supen'loon lho.l •lu>do.td operaUn[ p~uns or l&!e ho.,e received and 1uo::eadully 00:n-worll. pracllcu; o.nd. ldenUllc&Uon of plet.ed lhe traJn1ns and field nperi-n,,.,....l medlcal MBlalulce. ence apedfled In po.raQ&Pha (ellll, . (tl 7'rgjnf{;£. Ill All emploJ-lluch <ell21 and <ellSl of lhla aecllon oho.II be .. ut nol 17W l.o equipment o;,,n.-certified bJ lhelr lnru-uclor u hnlna ton a.nd 1enen.J la.borers) n;:pos,ed t.o ooroplet..ed lhe neceaa.u-J' lra!nln&. Any huudow 1ubllt&nce&, heo.llh h■.u.rcls, pcroon who hM nol been ao ccrtl!led or sa.JetJ h~ ahall be \.horou1hly nor meet.a lhe requirement.a of pa.n.-t.nlned In lhe lollowin.:: P'Ph le1<8l of lhla occllon oho.II be Ill Names ol penonnel o.nd oJu,r-prohibited from en1...-1n& In hu.ud• . n1.l.a reaponslble for 1lt.e aa.Jely a.nd ous wut.e opc.rallona a.ft.er March 18. . health; 18B1. 344 (1) Employees who a.re reaponalble <Iv) M aoon u poaal ,,on nollfl· for reapondln1 lo hu.ardoua emeiaen-cation by an employee a.t the em-cy alluallona that may u:pose lhem to ployee ha.a developed 1111\B or 1ymp· ha.urdous aubst.ancea shall be trained Loma lndlca.Un1 possible over-1:xooaure ln how to respond lo expected emer• to ha.z.ardous aubfitances or hea.llh haz· 1encles. a.rd.a or that an unprolecled employee (8 J Employees apeclfled ln pa.rqra.ph hu been r:1.posed In an emer1ency alt-<e >< l > and rna.naaen specified ln para-ua.Llon. 1raph (e)(3J of Lhl.5 aecllon ■hall re-<v) Al more frequent times, If the ex-celve elsht. houn or refrcaher lnJntna-amlnln1 phyalcla.n deLermlnea lhat an umua.l)y on the tt.erna ■pecltled ln lnctta.aed frequency or examlna.Uon la parqraph (e)(l) or lhla accllon and medically neceaaary. olher ttlevant t.oplca. (3 > Conttnt of m.t:d(cal uamtna.Uon.1 (8) Employers who can ■how by an and conniltciUon.1. ll> Medical examl-employee•■ work e1pcrience and/or nallona required by pan,cn.ph (f)(2) l.ninln1 Lhal lhe employee hu had or thla 1CCllon ■hall include a medical lnlt.lal tnlnln& equivalent to that. and work hlalory with ■peclal empha-lra..lnlnl requlred ln parqn.pha Ce)(l), ala on 1ymplorna related t.o t.he ha.n-(e)(2), and «e><3) of thla aect.lon ■hall dllna or haz.a.rdoua 1ubet&nces and be considered .. meelln1 lhe lnlU■J he■Jlh haurda o.nd l.o fllnCM for duly tnlnln& req:ulrementa or lhoee para-tncludina lhe ablllty to wear any re-ll'&Pha u to that employee. EQulva-quired PPE under condlllona <I.e., t.em-lenl t.ta.lnlna: lncludea the tnlntns that perature exlnmea) thal may be ex-exlatln,a: employees ml1ht have alr-Hdy peeled at lhe work 11Le. received from a.ctual. on-alte experl-(ti) The content or medical ui:amlna• . ence. Uona or conaullaUona ma.de available (f) lfed~~~ntt-C:1) Em-to employeea punuant to para.uaph plow-ee, CO ~ ca.i aunelllance (f) ■hall be detennlned by the e1.amln-proar,un ahoJI be lnalllut.ed by lhe cm• Ina phyalclan. , ployer for lhc followlnc employeea: (4) Ezamtna.Uon bl' a ph,,t.etan an.d (l) all .e.rnployeea who are or may be coat.. All medical e1.amlnallona and es~ to .hu.a.rdoua subet.a.nces or procedure. ■hall be performed by or heallh hu.arda at or ■.hove the eat.ab-under the aupervlalon of a llcenaed llahed permiMlble _expooun, llmlta for phy■lcl&n, o.nd oho.II be provided with· theae •ubel&ri~. wit.bout rcs-ud to out coat to the employee, without loaa Lhe we -a, reapliat.,;>n, for IO day■ or or pay. and at a n:uona.ble time and 1more a Je&r. · 1 place. ; 1111 ■JI .employeea who 'Wear a rapl-l&l 11\{ormallon prooltkd to 1M ph~-/ r&Lor (or SD daya or more a year; and ncta.n.. The employer ■hall provide the '-._ / UUl H.AZMAT employeea •~llled In followlna lnlormallon lo the namln-.. po.n.anph llll4) of lhlll aecllon.· --.. .. Ina phyalclo.n: (2) T,..,,_ of medico.I uamlna-~,. (I) A copy of lhlll ,und&rd o.nd Ila flon, an4 con,wJl411om. Medical H· o.ppendlces arnlnatlon■ a.nd c.onaultatlona ah&ll be . Ul) A d~ptlon of the employee's made available by the ,.employer t.o dullea u they rela.te to the employee•a each employee covered under pa.n.-ST&Ph <!Mil of lhla oecllon·on lhe fol-expoourea, lowlnc achedulea: _; / (Ill) The employee'■ e1.poeure levels (l) Prior to aaatrrunent or for em• or anllclpat.ed espasu.re levela, ployees covered on the eUectlve date <Iv) A deterlpllon or any penonal ol thla ounda.rd u 1pecl!led In pua-prolttllve equipment uaed or lo be ""1h (pl ol lhla ■«lion. Ulltd, and <lll At leaat once every twelve (V) lnformaUon from prevloua medl-montha for ea.ch employee covered. cal e1.1.1Dlnatlona or the employee (Ill) At t.ermlnallon of employment which la not rekdlly avallable to the or rea.aalrnmtnl to a.n area whett lhe exa.mlnlnc: phyalcl&n. employee would not be covered U the lG) Phrddan •, wrltUn opinton. (I) employee hu nol ha.d l.ll e:umlnatlon The employer aha.II obtain and furnish wtthln the laat als months. the employee wllh a copy or a written 345 I I f I I I I I I .. I I I I I I I 'f I point 7 % • varies It is from 27°C flammable with 45°c. The LEL is a moderate fire 1 % and the UEL is risk. It is toxic by ingestion and inhalation. It is also an irritant. Common routes of entry are inhalation, absorption through skin and eyes, ingestion, and skin contact. Symptoms of exposure include dizziness, excitement, drowsiness, incoordination, staggering gait, irritation of eyes, nose, and throat, corneal vacuolization, anorexia, nausea, vomiting, abdominal pain, and dermatitis. Treatment should consist of immediate irrigation of eyes; prompt washing of skin with soap and water; artificial respiration for breathing difficulties; and do not induce vomiting for ingestion. Target organs include central nervous system, eyes, gastrointestinal tract, blood, liver, kidneys, and skin. The permissible exposure levels are 100 ppm (TLV: 100 ppm, TWA; 150 ppm STELi. The IDLH is 10,000 ppm. Safety precautions include clothing which will prevent repeated prolonged contact; goggles which prevent a reasonable probability of eye contact; washing promptly any area which becomes contaminated; and immediately removing any clothing which becomes wet to preclude the hazard of flammability. Anthracene is a yellow crystal with blue fluorescence, Its melting point is combustible with is . 00012 mm. It 217°C and its boils at 340°C 355°C. It is a flash point at 121 °C. Its vapor pressure is moderately stable in the environment. .It causes dermatitis and skin disorders. One source states that is is a carcinogen while an EPA report listed it as not being considered to be carcinogenic. It may have weak carcinogenic potential. Little information concerning acute and chronic toxic effects is available. An intraperitoneal LD50 of 430 mg/Kg is reported in mice. Skin tumors were reported in rats following subcutaneous administration and liver tumors followed administration. No data for establishing exposure levels available. Safety precautions would include limiting contact. 20 oral is I I {t I I I ·I I I .. I I I I m g I f u Fluorene is decomposes a white, crystalline at 295°C. It is information was discovered. solid. It melts at 116°C and combustible. No additional Phenanthrene is a colorless shining crystal. It melts at 100°C and boils at 340°C. It is combustible and its vapor pressure is 0.00068 mm. It is carcinogenic and caused tumors in two skin painting studies. Workers exposed to it developed dermatitis and skin disorders. Little information concerning acute and chronic toxic effects is available. No data concerning exposure levels is available. Safety precautions should include limiting contact. The are final 3 compounds, polynuclear aromatic basically solvents. 4.2 EXPOSURE PATHWAYS phenanthrene, hydrocarbons anthracene, ( PAH) . The and f 1 uorene others are Inhalation, dermal absorption, and ingestion are all potential exposure pathways, although inhalation and dermal absorption are the primary routes of exposure. Ingestion is not likely but may result from the practice of poor personal hygiene. In general, the PAH' s are crystalline solids and are not highly volatile. The PAH' s of low molecular weight are an exception. Anthracene and phenanthene volatilize or sublime to form vapors in the atmosphere. In addition to the vapor, inhalation of contaminated particu-late matter is another potential hazard. High concentrations of solvents and PAH contaminants in the soil indicates that caution should be exercised during excavation in this area. A summary of . regulatory monitoring information in Table 4-1. exposure guidances and other for compounds of concern is 21 pertinent presented - "' "' -.---- Compound Trichloroethylene Tetrachloroethylene Chlorobenzene Ethyl benzene 1,2-dichlorobenzene Toluene Xylene Anthracene Fluorene Phenanthrene ---s ---- TABLE 4-1 REGULA'I'ORY EXPOSURE GUIDELINES AND MONITORING INFORMA'l'ION FOR CHEMICALS OF CONCERN PEL IDLH TWA STEL 100 ppm 1,000 ppm so ppm 200 ppm 100 ppm 500 ppm so ppm 200 ppm 75 ppm 2,400 ppm 100 ppm 100 ppm 2,000 ppm 100 ppm 125 ppm so ppm 1,700 ppm 50 ppm 200 ppm 2,000 ppm 100 ppm 150 ppm 100 ppm 10,000 ppm 100 ppm 150 ppm (LDso = 430 mg/kg mice) - PEL -Permissible Exposure Limit -OSHA (8 hr. time weighted average) IDLH -Immediately Dangerous to Life and Health TWA -8 hr. -Time Weighed Average -Recommended Threshold Limit Value STEL -Recommended 15 min. -Short Term Exposure Limit - Carcinogenic Weight of Evidence Suspect No No No No No No Suspect Suspect - I I f' I I I I I I -I I I I I I I •• I 4.3 PHYSICAL HAZARDS The activities to be performed at the Sandoz remediation project include work involving heavy construction equipment and storage piles of contaminated soil. Personnel should be aware that the personal protective equipment limits dexterity and visibility, and may increase the difficulty of performing some tasks. Prudent care should be exercised when moving about machinery of any kind while wearing protective equipment. The protective equipment worn may place a physical strain on the wearer, particularly during periods of warm weather. Under these conditions, heat stress and exhaustion may occur. Heat stress may produce symptoms such as nausea, headache, weakness, dizziness, or extreme perspiration. Heat stroke, a critical situation, is characterized by a sudden lack of perspiration and requires immediate medical attention. All personnel should be monitored for heat stress by the SSO or his designee following the guidelines established for heat stress 7. 7 of this HSP and in Attachment F. See monitoring Attachment in Section F for more information concerning heat and cold stress symptoms and emergency measures. Personnel should be cognizant of wind directions and attempt to coordinate field activities and gasoline powered equipment such that exhaust fumes are located downwind. The slopes of the berms located on-site should be considered only marginally stable. Care should be taken when moving about the area. It is anticipated that contaminated soils will be relocated using a front-end loader or backhoe. As material is removed, the excavation area may become locally unstable and material may flow or slough down from higher levels. Workers and monitoring personnel should keep a safe distance from the work area. 23 I I f I I I I I n I I I I I r' I Personnel must insure that safe clearances from utility lines are maintained prior to and during excavation or other activities. Care must be taken to prevent accidental contact of equipment with the power lines. OSHA Construction Industry Safety and Health Standards shall be complied with for all construction activities. 24 I I {' I I I I I I .. I I I I I I I ,. I 5.0 HEALTH AND SAFETY PROGRAM ORGANIZATION The MoTec Health and Safety Progam incorporates the following personnel: corporate he.al th and safety officer; project manager and site safety officer. The responsibility and authority of each of these individuals with regard to the MoTec Heal th and Safety Program are outlined below. CORPORATE HEALTH AND SAFETY OFFICER (CHSO): Responsibilities * Direct the implementation of the health and safety program of the operating group and provide recommendations for improvement of the program. * Coordinate all health and safety activities. * Review health and safety plans . * Investigate reports of incidents or accidents and report accidents or incidents to the Corporate Headquarters. * Carry out employee health and safety training in the operating group. * Monitor implementation of health and safety plans. * Determine whether an accidental exposure or injury merits a change in the affected individual's work assignments and whether changes in work practices are required. * Determine need for project health and safety plans. Authority * Approve or disapprove health and safety plans. 25 I I I I I I 19 I I I I I I I •• , I * Access project files. * Direct changes in personnel work practices to improve health and safety of emloyees involved in hazardous waste management projects. * Remove individuals from projects, if their conduct jeopardizes their health and safety or that of coworkers. * Suspend work on any project which jeopardizes the health and safety of personnel involved. PROJECT MANAGERS (PM): Responsibilities * Assure that their projects are performed in a manner consistent with the MoTec health and safety program. * Assure that project health and safety plans are prepared, approved and properly implemented. * Provide the CHSO with the information needed to develop health and safety plans. * Implement health and safety plans. * Assure that adequate funds are allocated to fully implement project health and safety plans. * Assure compliance with contractor personnel. health and safety plans * Coordinate with the CHSO on health and safety matters. Authority (Safety Related) 26 of I I {' I I I I I I .. I I I I I I f I * Assign CHSO approved SSO to project, and, if necessary, assign a suitable qualified replacement. * Temporarily suspend field activities, if health and safety of personnel are endangered, pending an evaluation by the CHSO. * Temporarily suspend an individual from field activities for infractions of the health and safety plan, pending an evaluation by the CHSO. SITE SAFETY OFFICER (SSO): Responsibilities * Direct health and safety activities on-site. * Report immediately all safety-related incidents or accidents to the CHSO and project manager . * Assist managers in all aspects of implementing health and safety plans. * Maintain health and safety equipment on-site. * Implement emergency procedures as required. Authority * Can temporarily suspend field activities, if health and safety of personnel are consideration by the CHSO. endangered, pending further * Can temporarily suspend an individual from field activities for infractions of the heal th and safety plan, pending further consideration by the CHSO. 27 I m {' I I I I I I .. I I I I I I I •• I 6.0 GENERAL HEALTH AND SAFETY REQUIREMENTS 6.1 HEALTH AND SAFETY TRAINING All individuals involved in hazardous waste operations exposed to hazardous substances, health hazards or safety hazards shall at the time of job assignment receive a minimum of 40 hours of initial training and 3 days of actual field experience under the direct supervision of a trained, experienced supervisor. On-site management and supervisors responsible for or who supervise the employees must receive an additional eight hours of supervisory training on managing hazardous operations. 6.2 MEDICAL SURVEILLANCE A medical surveillance program shall be instituted for the following employees: * All employees hazards at or (PEL) for 30 exposed. to hazardous substances or health above the OSHA Permissible Exposure Limit or more days a year ( regardless of the use of respirators.) * All employees who wear a respirator for 30 days or more a year. The medical examinations shall include a baseline physical, annual physical, and a physical at employment termination or job reassignment. If an employee develops signs of symptoms indicating possible overexposure to hazardous substances or health hazards then a medical examination will be conducted. Medical examinations shall include: * A medical and work history emphasizing symptoms which may be related to the compounds of concern at the site and health hazards and fitness for duty . 28 I I I I I I .. I I I I I I I f I All other medical surveillance requirements in 29 CFR 1910.120(f) will be followed by the employer (Attachment A). An employee must also receive written clearance to wear a respirator by a qualified physician. 6.3 SAFETY BRIEFING Site Safety Orientation Meetings All hazardous waste field personnel must attend a safety orientation meeting before commencing field work. The meeting should be scheduled and conducted by the Leader or Site Safety Officer. The requirements of this plan will be reviewed at this meeting and include the following: * contaminants and exposure pathways of concern * required health and safety protection equipment * controlled access to restricted work zones * health and safety monitoring procedures * decontamination requirements and procedures 6.4 DISTRIBUTION OF HEALTH AND SAFETY PLAN Al 1 employees involved in hazardous waste site operations shall receive and read a copy of this plan prior to commencing field activities and sign a safety compliance agreement form (Attachment BJ. The signed compliance agreement form shall be given to the Site Safety Officer for placement in the project files. 29 D • I' I I I I I I .. I I I I I I I f I I 6.5 INCIDENT REPORTING Any accident ( s) or incident ( s) involving subcontractor personnel will require that Report be filed. This includes incident(s) wee personnel or an Incident/Accident or accident ( s) that involve exposure or injury to MoTec personnel that occurred while performing ( or as a result of) activities associated with the project. The report will be completed on the Incident/Accident Report Form and submitted to the MoTec Business Unit Health and Safety Officer within 24 hours. 6.6 SAFETY COMPLETION REPORTS A final Safety Completion Report will be submitted by the Site Safety Officer to the Business Unit Health and Safety Officer and Project Manager upon the termination of the project. The Safety Completion Report will be used to evaluate the effectiveness of the Site Safety Plan in controlling the amount of exposure to potentially hazardous situations. The report should address the following issues: * Mention of any health and safety incidents * Describe methods used in monitoring various contamina- tion parameters. * Monitored concentration levels observed in the use of prescribed monitoring equipment * Comments on the health and safety protocols * Decontamination related comments 30 D I {' I I I I I I ID I I I I I I I f I 6.7 PROHIBITED ACTIVITIES Prohibited activities during site investigation work are those actions not related to work activities which could unnecessarily result in contact, inhalation and/or ingestion of hazardous substances. These actions include eating, drinking of food or beverages and smoking or chewing of tobacco during field activities and at any time prior to decontamination of personnel protective equipment. 31 I I I I I I .. I I I I I I I {' I 7.0 SITE SPECIFIC HEALTH AND SAFETY REQUIREMENTS 7.1 SITE CONTROL/SECURITY Security of the overall facility is currently provided by 24 hour guard service and a partial fence. Access is controlled by locked gates and a guard post on Highway 27. MoTec operating procedures for site control are presented in Attachment D. Visitors' access to the site shall be controlled by Sandoz, the Project Manager (PM), and the Site Safety Officer (SSC). Before going within a restricted work zone, the PM or SSC shall be notified and the Site Safety Plan shall be provided for the visitor. The visitor shall sign a consent document indicating that this site safety plan has been read and understood. A visitor must also provide evidence of clearance from a qualified physician to wear a respirator (if required). 7.2 WORK ZONES The restricted work zone shall surround the land treatment unit and shall be indicated by barricades or posts. Signs shall be placed on the posts or barricades instructing unauthorized persons not to enter the restricted work zone. Work activities during these operations will be divided into two basic categories: intrusive and nonintrusive. work shall include the following: Intrusive * any work which requires direct contaminated soil; including washing process; or indirect contact derocking, weighing, with and * the collection of contaminated soil for sampling and chemical analyses; 32 u I I I I I I .. I I I I I I I •• I * operation of heavy equipment for excavation, spreading, or rototilling contaminated soil; * any work within the designated exclusion zone or areas of known contamination. Nonintrusive work shall include the following activities: * any work related to and treatment drying bed and not within the exclusion in the vicinity of the land the soil washing equipment but zones including supervision and oversight of work activities; * operation of vehicles for transport of contaminated soil. Since a preliminary survey of the area scheduled for installation of the Land Treatment drying bed indicated no overt soil contamination, preliminary staging of this area for placement of contaminated soils will not be covered by this health and safety plan. following: Activities excluded from this HSP include the * construction of the berm surrounding the drying bed * preparation and construction of the soil procesing area * other preparation activities which do not require direct or indirect contact with contamianted soils The drying bed shall be considered an exclusion zone when excavated and washed soil is placed in it or the soil processing (rock removal) area. The drying bed shall be appropriately identified as an exlusion zone prior to placement of contaminated soils in that area as outlined in Section 7. 2 and Attachment D. 33 I I I I I I • I I I I I I •• I The SSO and the PM or their designee shall be responsible for determining whether drying bed preparation activities ' worker health or safety or result in any exposure jeopardize of workers to contaminants. Work activities shall cease if such a situation exists and until such time that the situation and personal protective measures are assessed by the SSO, CHSO, and PM. 7.3 DUST CONTROL The soils to be removed from the stockpile will be dampened as necessary, prior to and during excavation and at any other necessary times to reduce the potential for fugitive dust emissions. 7.4 PERSONAL PROTECTIVE EQUIPMENT Personal protective equipment for nonintrusive work shall include the following: *hardhat * uncoated coveralls * nitrile or neoprene overgloves * boots (waterproof with steel toes) Personal protective equipment for intrusive work activities shall include the following: *hardhat * safety glasses or goggles (if full face respirator is not being worn) * coated coveralls (polycoated Tyvek or Saranex) * nitrile or neoprene outer gloves * boots (waterproof with steel toes) * half-face respirator with goggles or face shield, or full face respirator, both with organic vapor/HEPA combination cartridges (see below). 34 E I • I I I I I I I .. I I I I I I I •• 'I Adverse weather conditions include both cold air temperatures (<50 degrees F) and excessive rain. Buffer periods are incorporated into our project schedule to allow for delays caused by adverse weather conditions. Progress will be monitored· by analysis of the material. After the washed soil is deposited, analyzed. When these reach treatment levels, an be presented for payment. 14 decontaminated it will be invoice will I I {' I I I I I I .. I I I I I I I •• I CRITICAL PATH ACTIVITIES Site Mob Pull Equipment to site Deploy equipment Connect power Initiage Biotreaters Remediation Operation a) Weigh material shaker/shredder b) Derock material c) Slurry soil d) Continured washing e) Biodegradation of fine stream f) Solid separation g) Deposition of treated material h) Rock washing i) Grade site Demob Equipment Front end loader portable scale Power shaker) Mobilcrete Rock polisher) Sludge MiKIE Hydrocyclone Sludge/concrete pump Power washer water pump Bulldozer Wash/decon equipment (Rinsate to biotreaters) Break down equipment Dishcharge decontaminated water Pull off site 15 Manpower 1 man load 1 man 1 man 1 man I I I I I I .. I I I I I I I •• I SOIL "FIGURE 8" SCHEM ,4 7/c. 5.t-oc,<-- ,0//~ . ,&>owe,,.. .sha..f'-,. ' ,K;" c.ks > 3" ' , w • ..,-, fYJOIJ L C ,?ET F , . /,,Vv·Lt:-y- ' ., , SO/ ,',:;I_,- --i . S:e/ d ,-o r ;~,,, l?ock.5 > l{, ,, , y tln,'t F111e.s ' , Sl'-trr~ /1., le. . Koc?J L .5C: c. FLL S Wa.sh~cl 3 cl2v->-' Y~51dence /fi'ns.t ~e,. • ,e,,,,/ A1 ''!5 -~ //y,J~o cyclu11c , l?af"O.S ,'re,, ,Y - C./e~ "l /)4!..Co1tf.:,,.-, /..,~t<l!f/' WJ t • .,.. I I {' I I I I I I .. I I I I I I I {' I 4.0 HAZARD ASSESSMENT 4.1 CHEMICALS OF CONCERN Contaminants of concern tars and were deposited as spent solvents. distillation idenified by IV Atlanta. lab and process samples, The major ones were (ROD) issued by Region EPA in the Record of Decision They are trichloroethylene, tetrachloroethylene, chlorobenzene, ethylbenzene, 1,2-dichlorobenzene, toluene, xylene, anthracene, fluorene, and phenanthrene. Trichloroethylene is a stable, low-boiling, colorless, photo-reactive liquid. It has a chloroform-like odor. It will not react with metals even in the presence of moisture. It has a freezing point of -73°C and a boiling point of 86°C. Even though it is volatile (vapor pressure = 58mm) it does not have a flash point. The lower explosive level (LEL) is 11% and the upper explosive level ( UEL) is 41%. It is toxic by inhalation and is an irritant. It is also suspected of causing cancer. Routes of entry are inhalation, · ingestion, and skin contact. Symptoms following exposure include headache, vertigo, visual disturbances, tremors, somnolence, nausea, vomiting, irritation of eyes, dermi ti tis, cardiac arrhythmiag and paresthesias. Treatment for exposure includes immediate irrigation of wash off skin with soap and water; artificial breathing difficulty occurs; and administration induce vomiting if injested. The target eyes; promptly respiration if of Ipecac and organs include respiratory system, heart, liver, kidneys, and central nervous system. Exposure restrictions are 100 ppm PEL, 200 ppm ceiling, 300 ppm peak (TLV: SO ppm TWA, 200 ppm STEL). The IDLH is 100 ppm. Safety precautions include clothing to avoid repeated, prolonged contact; goggles to prevent reasonable probability of eye contact; washing promptly when skin becomes wet; and promptly remove any non-inpervious clothing that becomes wet. 16 I I I I I I I .. I I I I I I I (' I Tetrachloroethylene ( perchlorethylene) is a colorless liquid with an ether-like odor. It is extremely stable and is nonflammable. It has a melting point of -2 2 ° C and a boiling point of 121°C. Its vapor pressure is 14 mm. It is an irritant to eyes, nose, throat, and skin. Routes of entry are inhalation, ingestion, and skin contact. It causes nausea, flushing of the face and neck, vertigo, dizziness, incoordination, headache, somnolence, erythemia, and liver damage. Treatment for exposure includes immediately irrigation of the eyes; promptly wash off skin contact with soap and water; artificial respiration for breathing difficulties; and administration of Ipecac to induce vomiting if swallowed. Target organs include liver, kidneys, eyes, upper respiratory system, and central nervous system. Exposure restrictions are 100 ppm PEL, 200 ppm ceiling, and 300 ppm peak for 5 minutes every 3 hours (TLV: 50 ppm TWA and 200 ppm STEL). The IDLH is 500 ppm. Safety precautions include clothing to prevent repeated, prolonged contact; goggles to prevent reasonable probability of eye contact; washing promptly upon contamination of skin; and promptly removing nonimpervious clothing which becomes contaminated. Clorobenzene is a clear flammable volatile with a liquid flash that has an almondlike point of 29.4°C and an odor. It is autoignition temperature.· of 637°C. It melts at 45°C and boils at 132°C. It has a vapor pressure of 8.8 mm. Its lower explosive level is 1.3%. The upper explosive level is 7.1%. It causes irritation of the skin, eyes and nose, drowsiness, incoordination, and liver damage. Routes of entry include inhalation, ingestion, and skin irrigation skin with breathing contact. Treatment following exposure includes of eyes immediately following contact; promptly wash soap and water; apply artificial respiration for difficulties; do not induce vomiting following ingestion. Target organs include the respiratory system, eyes, skin, central nervous system, and liver. The permissable exposure limits are 75 ppm. (TLV: 100 ppm, TWA). The IDLH is 2400 ppm. Safety precautions include clothing which will prevent repeated, 17 I I I' I I I I I I le I I I I I I I •• I prolonged contact; goggles which prevent the reasonable probability of exposure to the eyes; washing skin promptly when it becomes wet; and immediately removing any clothing which becomes wet to preclude flammability hazard. Ethylbenzene is a colorless liquid with an aromatic odor. Its vapor is heavier than air. Its melting point is -9 5 ° C and the boiling point is 136°C. The flash point is 15°C and autoignition temperature is 432°C. Its vapor pressure is 7.1 mm. The LEL is 1. 0 % and UEL is 6. 7 % . It is toxic by ingestion, inhalation, and skin contact. It is an irritant to skin and eyes, and mucous membranes. It is flammable and a dangerous fire risk. Routes of entry following are inhalation; ingestion, exposure are irritation and skin contact. Symptoms of eyes, mucous membranes, dermi ti tis, headaches, narcosis, and coma. Treatment following contact should include immediate irrigation of eyes; flush skin promptly with water; artificial respiration for difficulties; and do not induce vomiting following Target organs include eyes, upper respiratory system, breathing ingestion. skin, and central nervous system. Permissible exposure levels are 2000 100 ppm. ppm (TLV: 100 ppm TWA, 125 ppm STEL). The IDLH is Safety precautions include clothing to prevent repeated, prolonged contact, goggles to prevent the reasonable probability of eye contact; promptly washing skin upon contamination; and immediately remove any clothing that becomes wet to avoid flammability hazard. 1,2-dichlorobenzene or orthodichlorobenzene is a colorless liquid with a pleasant odor. It has a melting point of -15 °C and a boiling point of 179°C -180°C. It has a vapor pressure of 1.5 mm. Its flash point is 65°C and an auto ignition temperature of 647°C. The LEL is 2.2% and the UEL is 9.2%. It is combustible and toxic by inhalation and ingestion. The common routes of entry are inhalation, ingestion, absorption due to skin contact, and eye contact. Symptoms include irritation of eyes and nose; liver and kidney damage; and blistering of the skin.. Treatment includes immediately irrigating eyes; wash skin with soapy water 18 I I i' I I I I I I .. I I I I I I I i' I promptly after contact; artificial respiration for breathing difficulties; and administering Ipecac to induce vomiting for cases of ingestion. Target organs are liver, kidney, skin, eyes. Permissable exposure levels are 50 ppm (TLV: 50 ppm TWA). The IDLH is 1700 ppm. Safety precautions include clothing which prevents repeated, prolonged contact; goggles which prevent reasonable probability of eye contact; washing immediately upon becoming contaminated; and promptly removing any non-impervious clothing which becomes contaminated. Toluene is a color less liquid with a benzene-like odor. It has a melting point of -93°C and a boiling point of 111 °C. It is a flammable liquid with a flash point of 4°C and an autoignition temperature of 536°C. The LEL is 1.3% and the UEL is 7.1%. It is a dangerous fire risk and is toxic by inhalation, ingestion, and skin absorption. Routes of entry are inhalation, ingestion, skin and eye contact, and skin absorption. Symptoms of exposure include fatigue, weakness, confusion, euphoria, dizziness, headache, dilated pupils, lacrimation, nervousness, muscle fatigue, insomnia, paresthesias, dermatitis, and photophobia. Treatment for exposures include immediate irrigation of eyes; promptly washing skin with soap and water; artificial respiration for breathing difficulties; and do not induce vomiting for ingestion. Target organs include the central nervous system, liver, kidneys, and skin. The permissible exposure levels are 200 ppm, 500 ppm ceiling, and 500 ppm peak (TLV: 100 ppm TWA, 150 ppm STEL). The IDLH is 2000 ppm. Safety precautions include clotl1ing to prevent repeated and prolonged contact; goggles which prevent a reasonable probability of eye contact; washing skin promptly upon becoming wet; and immediately removing any clothing which becomes wet to prevent the hazard of flammability. Xylene is a clear liquid and most samples are mixtures of three isomers. The boiling point ranges from 135°C melting point for most commercial mixtures ranges to -48°C. The vapor pressure ranges from 7 to 9 mm. 19 l45°C. The from -23°C The flash I .. I I I I I I I .. I I I I I I .. I I FIGURE 4 ANALYTE CONCENTRATIONS (ppb) IN GROUND-WATER AND SOIL SAMPLES FROM AREAS A AND B October, 1986 to January 1887 p EBw1.•1 1.1•1' .•-t•I ~IND Cl • 7.1 ~ T • a.a -· LEGEND • • 1.1-10· ND 11.1-20· ND •... , ~-, .......... ., ... ~..,, ........ .. --. ...,. __ ................ , .. "'" ....... , ...... PIND•._....._., ........ NO•,..,,._._...._ .. tcl---4CI • hrn ; ... .-,.... ca.--. ...... ... 11-,. ...... ODCI• ............ .._ T• ,_..,.. I•.,.._, ,_,._._.....,., .... I•,.,.,..-., ....... .,.._ 0 ............ .... "D•Cll•41 ciDca -21 0 ICAL.E o\•1•1 0 1.1-1· ND 100 PEET I .. I I I I I I I .. I I I I I I .. I I Boring B-2-1 lies betwen CERCLA Areas A and B and shows ug/Kg and at depths chlorobenzene .concentrations of 220 and 43 0-dichlorobenzene concentrations of 85 and 26 ug/Kg of 23.5 to 25 feet and 28.5 to 30 feet, respectively. Since this boring lies downgradient of Area A and at a depth within the water table, the contamination most likely indicates organic migration in the direction of the groundwater gradient from Area A towards Area B · \ Figure 5 shows the locations of groundwater sampling wells where I ::,:::::ic 0 ::::::1•:::: :::o::::cc::· WQ-5A, which is located about 100 edge of Area B. samples feet from from well cluster the southwestern These results indicate that the upper aquifer zone is not contaminated. Th~ intermediate aquifer zone in the vicinity of CERCLA Area B shows contamination with tetrachlorethylene, chlorobenzene, and o-dichlorobenzene, and the deep aquifer zone shows much lower concentrations of two of these three indicator parameters (chlorodenzene and ortho-dichlorobenzene). AREA C Figure 6 depicts the soils and groundwater sampling locations in Area C and listb all analytes detected with their respective conconOcaOions. I The results from the samples define the maximum boundary of the · d ·1 .I h h' . d contaminate soi in Area C. In t e past, t is area containe three trenches or pi~s, C-1, C-2, and C-3. 9 ------- ._j-:--.lff---,/...__..: a-11 • 'iJ 0 II l\ wa-1, . 0 Cji ,, :a:J ' .. . N4--L.._,.,._ ND 'er .. ~ .. , ,- ...... LOCATION OF GROUND-WATER SAMPLING WELLS WHERE ORGANIC COMPOUNDS WERE NOT DETECTED December, 1986 io January, 19Br ~ ---- LEGEND - • • l.,, -r • Oren4 Wal~ IIO • ..,alrtoo w.t -.. 1., ·-. -----. ---:-:---:: ~E 01 .• I 100 ' -1-. -'-· .,.1 fEEl "'-• - ,.,. --.----- --- --- ANALYTE CONCENTRATIONS (ppb). IN •. SOIL AND IN GROUND-WATER ./ SAMPLES FROM AREA C • <\. U-1' C'I -IN ODCa-H October,· 1986 to January, 1987 /,t? ~~:~ ,_,._,. .,_._ .,_o r,,'I' \. U -u...-' e-r IJ-.-ooce -•. .-...... I.a-• N.l·N" -A • IN D.1-lf' ca -IN OOCit.-a ~~ _.,.__~---- t------t • • -........ a -•·• • ooca - " U-1" U -h ~ ~--.-CW -a...HC •-••w ooca -111 11.1-,,. ooc:e -"' a.1-w t-------4 DOCS -tH.... f -•t OKe -IN ca -IN 1.1-W a -111 • .-. a -I.NO 1 .. II 1.1-• ooc:a -N "" 1--------1 ,. • -II ~ a -•• '-~~----.. , -\ DOC8 ... ,,. ...... ooa'~-:~~ ~-----~ ~ I ~ ;°'_._. • ooca: •·• a _ •n.-Al --11111 \ ~ ..,-;:===--- - - I.EGENO [ ---, ... ___ _ ---· • • _____ .,_ ---------,_ ___ .. _ ---.................. •------•-............ .tea--------ca----.. n-•----..,._ ... __ _ ·--•--................... ,--------. I\_ , ~'\ ~--':,. rc::::. ~: ll-1' 0 IJ-1' • '\ '\ 11 ~.-& •--ca .. IH --a..1-•· • a.a-a-c-1-. . '\ · ---• •---I ooca -t..■N ,,,,.,."...--. -~it_... • -... w,..... , ' )\ 11.t-H' ,' ', c-1-1 ·, ~IIQ-N .a-at ••:::r ... ooca-•1.,.. , . ., ca-a. ... \ ' l.lt-S' -- I -JI.. ... J-~---' A-11 / --N t-----'---t --, C-1;_1 I■ ~ ,_. I• tr IU-H ', ' OOCII ,-on O.l>-W . / / \L\ _ _;:_ __ J I -...... 'C-1-1 I -ca n C•~•-._/' --. , I 1.1-w '\. "":1-4 .. ../. . --.-' l-• .,. -n ,.' • ', , •1 • -•ct -n I IM --.., t:._c-S~ '•~~~.-1-..... ~, c-1-1 1 _ 11 ~ // -l~ · • I , ... _,, c-1-n / . ,._._,.. c-a-a WL-a / -::::. , ooc.-n c-a-1 (n/ . ~ --M .;_,_.,,~( .. C " . ~--~ '~-\ ... , . -J"!-:i:-:., ~ !------~------OK:a -1... -I' ,_ __ ;__, ca:-ti I•••-C-. ·, U-1' .._,._ .. Lf-1' --l ■ -IU,"9 !----'-----1 occe -1.rn . .w •-•--........... " ca -I.Ht 1------~ ,. -,.~ ....... I .. '-.'" ll -Ut.H: <------1 o:,::::a -U..,"9 I -t_PH,"'9 LI-W ••-•" .... ooc:a -""·-" •-t..•" ..... .._,._ .. ti -'" ..... CIOCa• IH,He ' -"··" • -,,,..., ... •• 1-N" II -:tH, ... D0Ca-4H.e-M I .. l,"11, ... ILi-i"(" OP:W • IN I• UC \ \,\ \ ...... n-a. .... 1-rn_... .... ff I ' -._._ ... -, .... -._....---'~-----' 11..1-lf" ' G9Ca -f.4 ... -------1-=-----t.1-W ooca -•• n -\ . _ .. ._.. .. ca-n II -If •-- I \ 0 IO s::.ot.£1 ~-..,_, _ _,, FE£T - I •• I I I I I I I .. I I ·I I I I I ·• I I Based on the boring analyses and field approximately 5,800 cubic yards of uncontaminated soil cover in Area C. observations, contaminated there soil are and Four wells in the immediate vicinity of Area C were sampled: WQ-27, WQ-28, WQ-29 (well cluster), and WQ-34 (well cluster). Well WQ-6 is considered the shallow well of well cluster WQ-29. AREA D Analyte samples sampled concentrations detected in the soil and groundwater from Area D are shown in Figure 7. Boring D-1-3 was twice. The volume of contaminated soil is about 40 cubic yards with about 75 cubic yards of cover soil. All aquifer zones of well cluster WQ-33, which are located approximately 75 feet south of D-2-2, are contaminated with volatile organics . These results indicate that contaminants in Area D have migrated downward into the alluvium, gravel and upper bedrock zone to an 84 foot depth. Groundwater flowing through Area D discharges into the Catawba River. 2.5 OBJECT OF THIS REMEDIATION The contaminated area, Area C, originally was formed by three trenches used for disposal of laboratory and production samples, distillation tars, and waste solvents. The contaminants of concern are trichloroethylene, tetrachloroethylene, chlorobenzene, ethylbenzene, 1,2-dichlorobenzene, toluene, Xylene, anthracene, fluorene, and phenanthrene. In the spring of 1981 the contents of pits C-1 and C-2 were dug up and removed to a secure landfill in Pinewood, SC. In the spring of 1983 pit C-3 was also excavated and relocated to the 10 I I·. • I I I I I ·- I I .. I I I I I I .. I I IN ANALYTE CONCENTRATIONS (ppb) GROUND-WATER AND SOI~ SAMPLES FROM AREA·o October. 1986 to January, 1987 and kmpl• Z•Zl•l7 1,1 • ~ Cl • 11,000 . ODC:I • 1,000,000 .... D o., -1' ' Cl• 180 • 11 • 41 ODCI -:ai,ooo X • ~40 LEGENO l<,,;,,,,,j ..,,,.11 ... ,. U•II• ., CIII~.\ MH S "-•••llaate i.. .. , ... 11 -W..011.,1a1 W•II Gl11e&e, • Ille Cller1el1rl11I I -■ lltla .. G> Al>•••&1•111 "-••U•• II ,,n1e11elJ Dr!Ue, llrlo .. l Well& 4CI • T11ua111a, .. 111,11u Cl • CM1roo1n11111 II • 1111,1 ... •11•• •.. -.. Cl• 1,tOO 00c:1 -aa,1100 X • Z,700 00CI • 0-0111111,ea.1 1■-n• T • T••-• X • llflH•• ll V I• 4C:I • II ca -11,000 11 -:a.~oo ODCI • 11,000 T • 7,100 x • 4,aoo o -,ca -,10 Cl• U,000 II • 1110 Ol:ICI • :U,000 "t' • 2,700 X • 1,700 ,SIID • Pleld l•HIIH ll.C lklHlld I • 1u11ew A11111t., ia11e I • 1A11raldlt11 ""'11111, Z.111 D • 1>11, • -"11111., Zane I I· • I I I I I I I .. I I I I I I .. I I secure landfill. In both removals the material was removed until no visual contamination remained . At this point on additional 6" 12" of material was removed "l:o eliminate the final vestiges of gross contamination. CERCLA sampling from October 1986 through January 1987 discovered soil and groundwater contamination. Pit l (Cl) was found to have contaminants from 8.5 to 25 feet deep. The greatest contamination occurred in the 13. 5 to 15 foot interval. Pit 2 (C-2) exhibited varying of 25 feet. Pit 3 (C-3) contaminant concentrations to a depth was generally less contaminated than the other two pi ts, and is contaminated only to feet. The highest concentrations are found in foot depth range. 11 a depth the 8. 5 of to 15 10 I •• I I I I I I I .. I I I I I I •• I I 3.0 DESCRIPTION OF WORK 3.1 LANDFARMING PROCEDURES Normal Operation The contaminated area will be deep plowed to approximately 12 inches deep. This area will then be inoculated with a high biomass irrigant. the area will be aerated by 2 tractor As soon as applicable, driven rototiller. The aeration-irrigation/inoculation cycle will be repeated 2 or 3 times per week. The irrigant will be incubated in two 20,000 gallon mobile tanks, operated at a 15,000 gallon working capacity. The cultured, acclimated bacteria will be grown in a nutrient rich, aerated broth. Soil pH enhancements, if required, will be delivered via the broth. Standard operation and maintenance will consist of tilling/aeration of the treatment area, irrigation/inoculation, and recharging the incubation chambers. This will occur Setween two and three times per week. Additional aeration or soil manipulation will be accomplished by plow and/or disc harrow. 3.2 SOIL WASHING PROCEDURES Figure 8 represents a process flow diagram of the proposed cleanup methodology for the small project in Area D. Initially, MOTEC proposes to use an aqueous soil washing technique to reduce the contamination level in the soil. If further contaminant reduction is required, the soil will be subjected to a landfarming operation to continue biological degradation. The washing process intimately combines soil and bacteria and saturates the slurry with oxygen. Additional oxygenation and inoculation will be supplied during landfarming . 12 I I •• I I I I I I .. I I I I I I •• I I The soil washing process uses a biobroth and surfactant, either natural or commercial preparation, to enhance contaminant solubilization. After tl1e soil is slurried in the water stream containing surfactant (biological or commercially-prepared), it is vigoriously mixed in a Mobilcrete(R) soil mixer. A solids separation unit then removes large, easily settled particles. The slurry stream, containing the bulk of the contamination is sent to the LSC system. The stream is then conveyed to a hydrocyclone where liquids are removed. The LSC system accomplishes the bulk of the biodegradation work. Decontaminated water will be recycled for use in the sbil washing process. Past expericence has indicated that evaporative losses in the aeration system will alleviate water discharge. Thus, the aggregate treatment system (soil washer and LSC system) will function in a ''closed-loop'' mode. MOTEC projects a negative net water balance . The damp soils, still containing a significant population and oxygen level will be spread on the to undergo further degradation. A projected time to 14 days should reduce the contaminant levels biological drying area frame of 7 to target parameters. Additional inoculation and moisture will be supplied by irrigation with biobroth. Aeration, if required, will be effected by a tractor driven rototiller. (A schematic drawing outlining the sequence of events is included. Figure 8) The MOTEC process 25 cubic yds 200 cubic team cubic projects that yards per day. the soil washer can reasonably can be washed in will take six Thus the minimum amount of 150 days. It is anticipated that yards about ten days. Mobilization and demobilization will each add one week . 13 I Figure 2 -.. Sodyeco Site Map I I I • I } • I I I I .. I I I I I I .. I m I .. I I I I I I I .. I I I I I I .. I treatment, storage, and disposal of hazardous waste on-site . ' Waste water treatment and discharge activities are regulated under the NPDES program. Tl1e areas surrounding the Sodyeco Site are primarily undeveloped woodland, sparse residential and light industrial areas. To the north of the plant (and NC Highway 27) is an area of primarily undeveloped woodland. A convenience store, located immediately north of Highway 2 7, is not owned by Sandoz. The area to the east is primarily agricutural with sparse residential and light industrial areas. The area west of the Catawba River, which forms the wes,tern site boundary, encompasses the outskirts of the town of Mount Holly and includes a power substation, sewage disposal plant, industrial facilities and some residential areas. Approximately ·20-30 residents are estimated to reside within a one-quarter mile radius of the site. Because the Sandoz Chemicals Corporation is one of the largest employers in the area, many residents, including residents of Mount Holly and Belmont, commute daily to the plant. The most recent census (1980) gives a population of ·4,530 for the city of Mount Holly and 4,607 for the city of Belmont. 2.2 SITE HISTORY The Southern Dyestuff Company I Sodyeco) began operations at the current location in 19 3 G. Initially, the plant produced liquid sulfur (which dyes became ' from purchased raw Martin Marietta in materials. American 1961) purchased the Marietta Sodyeco. site in 1958. In the early 1960's, the company's product lines expanded to include vat dyes and disperse dyes. Since that time, the company has produced specialty chemical products for the agrochemical, electronic, explosive, lithographic, pigment, plastic, rubber and general chemical industries. Sandoz purchased the Sodyeco Plant from Martin Marietta in 1983 . 4 . iiiiii I I - AlfEAA NfEAE ·,-----·-· . CERCLA AREAS AT 11-lE SODYECO SITE • lEOEHO - • -'"~--. al CERCLA hM ----- -- (.'-.... --- --- I I I I --r w ---------------::--------...:---------5- - I .. I I I I I I I .. I I I I I I .. I I The Sodyeco Site contains five CERCLA facilities, identified as A, B, C, D and E ( Figure 3) . The following is a description of these CERCLA areas: AREA A This landfill's use began in the late 1930's. Waste materials disposed of at this facility included sulfur dye clarification residues, off-specification sulfur and disperse dyes, filter cloths, empty metal and cardboard drums and: cartons, small amounts of nonacidic, non-£ lammable discarded' chemicals and chemical wastes, and construction debris. The landfill was closed sometime between 1973 and 1974. Most of the area above the facility is now covered with asphalt and buildings. AREA B -,This landfill operated between 1973 and 1978 and received wastes that had previously been disposed in Area A. The area is presently covered with gravel and used as a truck staging area . AREA C -This area originally consisted of three covered trenches that contained the remains of laboratory and production samples, distillation tars, and waste solvents. The two northern pits were excavated in March 1981 and the contents were trucked offsite to a landfill in Pinewood, South Carolina. Removal of the remaining pit was conducted in 19 83. After excavation activities, Area C was regraded and grassed. AREA D -This area formerly contained two wastewater settling ponds. The ponds were taken from service in 19 6 6; one was cleaned out in 1973 and the other between 1976 and 1977. This area currently holds a lined fresh water pond and a fuel oil storage tank. A French drain is located immediately downgradient of the area to intercept shallow groundwater . 5 I .. I I I I I I I .. I I I I I I AREA E -No wastes are known to have been this area which located downgradient of manufacturing area. disposed the old of in plant The first indication of potential groundwater contamination at the Sodyaco Site was the discovery of organic sol vents in the company's potable water wall in September 1980. Contaminated groundwater was also detected in water supply wells adjacent to the plant. Residents of five homes were vacated and the plant water supply was changed from groundwater to surface water (Catawba River). In June 1982, a hazardous waste site investigation of the Sodyaco Site was conducted by EPA. and sediment· samples Results of surface water, groundwater revealed the pressence of organic contaminants in the groundwater and small amounts in the surface water . The objectives of the site investigation were to determine: * The population, enviionmental and welfare concerns at risk; * The routes of exposure; * The amount, concentration, hazardous environmental fate and transport, substances present; * Hydrogeological factors; properties, locations, and the form of the * The extent to which the substances have migrated or are expected· to migrate from the area of their original location 'and whether future migration may pose a threat to public health, welfare or the environment; * The contribution of the contamination to an air, land, water, and/or food chain contamination problem. 6 I .. I I I I I I I .. I I I I I I 2.3 HYDROGEOLOGIC SETTING The Sodyaco Site is located in the Piedmont Physiographic Province, a northeast trending zone metamorphic rocks. The Piedmont underlain by igneous and is subdivided into other northeast trending geologic belts. One of these, which contains the Sodyeco Site, is termed the Charlotte Belt. This characterized by residual soils developed from the chemical weathering of rock which was similar to the currently underlying the site. belt is in-place bedrock Groundwater recharge in this area is derived almost entirely from local precipitation. Generally, the depth to the water table depends on the topography and rock weathering. The water table varies from the ground surface in valleys (streams) to more than 100 feet below the ground surface in sharply rising hills . A groundwater divide is located approximately 50 feet north of CERCLA Area A and approximately 900 feet north of Area c.· In general, groundwater flow is northerly, north of the divide, and south-southwesterly, south of the divide. Average groundwater flow rates from the CERCLA areas to Long Creek were calculated to be approximately 180 gallons er day (gpd) from Area A, approximately 200 gpd from Area B and approximately 70-140 gpd for Area C. Estimated flow from CERCLA Areas D and E to the Catawba River were approximately 3,000 gpd and 10,000 gpd respectively. The primary hydrologic features influencing the Sodyeco site are the Catawba River (regional drainage feature) and Long Creek (major tributary to the river). Surface drainage from the western side of the site is directly to the river, from the northeastern area to the river via several small streams, and from the eastern and southeastern areas to Long Creek and then to the river. 7 I .. I I I I I I D I I I .. I I The five CERCLA areas are not within the 100-year flood elevation of Long Creek and the maximum recorded level in the Catawaba River since development of downstream Lake Wylie in 1904. 2.4 SITE CONTAMINATION The Sodyeco Site contains five CERCLA areas designated as A, B, C, D and E. Soil, groundwater, surface-water and sediment samples have been collected in and around each area and analyzed. All samples ha~e been analyzed for the following volatile organic indicator para.meters that were chosen based upon previous HSL scans at the Sodyeco Site: * Trichloroethylene * Tetrachloroethylene * Chlorobenzene * Ethylbenzene * o-Dichlorobenzene * Toluene * Xylenes Surface-water and sediment samples were also analyzed for three polynuclear aromatic hydrocarbons: * Anthracene * Fluorene * Phenanthrene In addition to the above analyses, two surface water samples from the Catawba River and two surface water samples from Long Creek ( upstream and downstream in each) were analyzed for the Hazardous Substance List (HSL) parameters. Since acetone was detected in many samples, acetone results are also reported. Acetone is believed to have been a laboratory and decontamination process contaminant. AREAS A & B Figure 4 shows the soil and groundwater sampling locations in and around Areas A & B includes the analyte concentrations detected. 8 I •• I I I I I I I .. I I D n I ~ I I 14.0 QUALITY ASSURANCE REPORTS TO MANAGEMENT A monthly quality assurance report shall be made to the project officer of MOTEC by the quality assurance officer of MOTEC, Chris Irwin. This report shall include assessment of data accuracy, precision and completeness for the preced- ing month. At least once during this project, audit shall be conducted with the a performance and system results reported by the quality asurance officer to the project officer. Significant QA problems and recommended solutions shall be included in each report. These reports will be summarized by the quality assurance and project officers for inclusion in the final project report. 36 I .. I I I I I I I .. I I R D D :I .. I I I .. I I I I I I I .. I I n D D I .. I I 1.0 PROJECT IDENTIFICATION 1.1 ADMINISTRATIVE INFORMATION Project Name: Location: Project Number: Administative Business Unit: Project Manager: Corporate Health & Safety Officer: Site Safety Officer: Authors of the Plan: Sandoz Chemicals/Sodyeco Site Mt. Holley, North Carolina 8813 Mt. Juliet, Tennessee Sam Wood Jim League Gerald Summey Jim League 1.2 APPLICATION OF THE HEALTH AND SAFETY PLAN The provisions of this Heal th and Safety Plan ( HSP) apply to the field activities to be performed during construction, implementation and data collection activities at the Sandoz Chemicals Sodyeco Site, Mt. Holley, North Carolina. Tl1e specific activities covered by this HSP are listed in Section 3. 0. This HSP describes the procedures to be followed and the protective equipment to be used by all MOTEC, Inc. employees and subcontractors working at the site. The health and safety guidelines and requirements presented herein are based on information available at this time and are subject to revision based on subsequent information regarding potential hazards at the site. As this plan is intended to minimize the potential for exposures to field personnel, all MOTEC personnel will be required to abide by its provisions. The compliance agreement presented in Attachment B will be signed by all MOTEC perso11nel 1 I •• I I I I I I I .. I I I I I I I .. I directly involved in site activities prior to commencement of work on the site. All on-site field work and field work performed in designated exclusion zones will be performed in accordance with the Occupational Safety and Heal th Administration (OSHA) "Hazardous Waste Operations and Emergency Response: Interim Final Rule", (29 CPR Part 1910.120, December 19, 1986) (Attachment A). In addition, all work on-site will be performed in accordance with the OSHA Construction industry Safety and Health Standards (29CFR 1926/1910). Appended to this Section is Sandoz Chemicals Safety Procedure (SP-23) (Attachment C). 2 I .. I I I I I I I .. I I m n 0 u ,._ I I I 1. 2.0 SITE DESCRIPTION AND HISTORY 2.1 SITE LOCATION AND DESCRIPTION The Sodyaco Site approximately 10 is located in Mecklenburg County, North Carolina, miles west of Charlotte ( Figure l). The City of Mount Holly is located across the Catawba River west of the plant. The plant site consists of roughly 13 0 0 acres ( Figure 2). It extends over 2000 feet north of State Highway 27, south past Long Creek, over 500 feet east of Belmeade Drive and is bounded on the west by the Catawba River. Of the approximately 13 00 acres at the Sodyeco Site, about 2 0 percent is occupied treatment facility. undeveloped . by production units and the waste water The majority of the remaining acreage is The Sodyeco Site contains an operating manufacturing facility consisting of and material production uni ts, a waste water treatment area, storage areas. The facility is partially fenced along open road frontage areas and a security clearance is required for entrance. The area in the vicinity of the Sodyeco plant is gently rolling, with elevations ranging from about 570 feet NGVD (National Geometric Vertical Datum of 1929) near the river to 670 feet east of the plant area. The original topography of the plant has changed considerably during its operation as the result of various grading and landfilling operations in conjunction with the construction of new facilities. As a result of previous studies, identified, whose use dates back to to the CERCLA areas, a RCRA permit 3 five CERCLA areas were the l930's. In addition has been issued for the I .. •• I I I I I I I .. I I I I I • .. g n ,$ • Figura 1 Site Location Map Sodyeco Site Mecklenburg County, North Carolina . ~ ~,. \a;;;;n·~~y "') • \...., I NORTH CAROLINA --\ Mecklenburg County ( ""' SODYECO SITE _____ ,_ I I I I I I I II I I I I I I F = Final volumme of solvent after dilution or concentration initial volume of solvent aliguot diluted or concentrated Results for all soil samples will be reported in mg/kg based on dry, weight of soil, calculated as follows: A(mg/kg) = B ( mg/1) X C(ml) X F D(g) /(100 + % moisture in soil) A = Sample concentration B = Concentration in extract C = Volume extracting solvent D = Weight of soil extracted F = Concentration or dilution factor as above Individual concentrations for all sixteen PAH compounds will be reported as mg/1 or mg/kg total PAH. All total PAH results for samples obtained from a single soil pile or treated soil unit at the same time will be pooled and used to calculate an arithmetic mean concentration and standard deviation of the concentration for that soil volume. Equations for calculation of arithmetic mean and standard deviation are given in Section 12. Results for soil or water samples taken at different times during biotreatment processes will be plotted versus time and compared to the various biodegradation models referred to in Section 12 in order to generate estimates of degradation rates. The GC/MS data for verification of cleanup will be treated similarly to the results generated by GC/FID at MOTEC for individual soil piles; i.e., an arithmetic mean and standard deviation for replicate analyses will be calculated and compared to the cleanup procedures contained in target concentrations "A Sampling Strategy using the for Cleanup of Dioxin in Soil," by Exner, Gilbert, not meeting cleanup target levels at level will be retreated. 22 and Kinnison. Soils the 95% confidence I I I I I I • I I I I g D All other analyses are considered minor measurement para- meters which are used to monitor operating conditions. Details of calculation of results are contained in the ana- lytical methods cited in Section 7.0. 8.2 Criteria for Data Validation Data will be considered valid and approved by the Quality Assurance Officer of MOTEC ( Chris Irwin) when a review of sampling information, preservation, preparation, analytical precision and accuracy data, holding time, and comparison to comparable previous data has been performed and all components judged acceptable. 8.3 Identification and Treatment.of Outliers Individual results from similar data which apparently (excessive deviation replicates, excessive deviation from will be treated as outliers only if: diverge drastically from the means for an apparent trend) 1) A review of data generation indicates a definite source of doubt as to the validity of the result. 2) A statistical treatment of the balance of data indicates the proposed outlier is beyond the 95% con£ idence limits for the rest of the data set. Outliers will be reported, but footnoted as an outlier and not included in statistical treatment of data sets. 23 I I I I I I I I I I I I I 8.4 Data Flow The data reporting process is outlined in the following flow diagram: 8. 5 0 ~ ... ,. Al;i;11hltla.i II rr1Hn1tla II u.,,. '"i,.ntt• Slort .. II M1l11t1 DIii ltan,. l1port lt«at.t ·- Su,ult lnfoM1111t.J0i, ~ ,o~ . -,, ... ,...,tlNI .. lafo,-,1,... . .. .. '1-tGtrlt1~ . IAfllrmtiM QC 0.tl f•1o• 1ttu ••• llllti.lt , ...... I ..... oc,y• ..... u,1. h,ort S.-. I I 1• _,, C1.11t ,,oJ, ,, l11h ,...,1o .. -.,~1""4 Tut.I ..... , ...... / ) ···•·•-ApJiro.-.d/ll1l11td Dd• 1oor, Atl1 I 7(1 I l11UrprU,1• .... -!, Kev Individuals for Data Handling Chris Irwin and Jonathan White will be responsible for assem- bly of all laboratory data and documentation. Chris Irwin will be responsible for data quality assurance and approval prior to release. Data will be analyzed and interpreted by Chris Irwin, Jim League, and John Bogart for process control applications. 24 I •• I I I I I I I Ill g n D I I ~ I I 9.0 QUALITY CONTROL 9.1 Check Samples, Spiked Samples and Duplicate Analyses In addition to the necessary calibration standards and rea- gent blank analyses performed with each batch of samples, the quality of data generated is monitored by analysis of a combination of control samples, reference materials, spiked samples, and/or duplicate analyses (with each batch of sam- ples or with every 10 samples if large batches are being run. In many standard analyses, control samples are used. A control sample is a stable material containing the analyte of interest, preferably in a matrix or substrate similar to that for which the analytical method was designed. Dur- ing the control sample analysis, if the calculated result is outside the previously established confidence limit for the analysis, the results must be reported to a supervisor. The supervisor and technician will trouble shoot the analysis and correct any problems before resuming testing. "Spiked" samples are used in place of or in addition to control samples; i.e., a sample is fortified with a known amount of analyte and analyzed before and after fortifica- tion. Percent recovery is calculated and compared to estab- lished acceptance limits for the analysis. Again, results outside the acceptance limits will result in trouble-shoot- ing and correction of problems with the analysis or identi- fication of matrix interferences. Another type of quality control check is the use of reference materials available from agencies such as EPA or NBS. If available, at least one reference material will be analyzed for PNA during this project. 25 I I I I I I I • I I I I I I •• I I In addition to the above QA analyses, duplicate sample ana- lyses are run; i.e., 10% of the samples are run in duplicate. Data are used to calculate precision for each procedure where applicable. 9.2 Field Blanks/Reagent Blanks Field blanks will be used to monitor possible contamination of samples during sampling. These blanks will consist of sample containers containing all reagents added to sample, such as preservatives treated exactly as field samples. Field blanks will be included in each set of samples obtained in a day and at least one filed blank per analysis will be prepared. Reagent blanks are run with each set of samples analyzed and include all reagents normally used during the analysis. They are used to document the absence of contamination in the reagents used in the analytical procedure including all sample preparation such as digestion, extraction, etc. The combination of field blanks and reagent blanks helps to locate any source of contamination and; thus, expedites remediation of contamination problems. 9.3 Internal Standards/Surrogate Standards Internal and Surrogate Standards are used in the GC/PID analysis of PNA. Specifics of their use are described in the procedure. 9.4 Split Samples Samples used for verification of cleanup will be first an- alyzed by GC/FID at MOTEC. Sort which has attained cleanup target levels will then be sampled and analyzed by an outside 26 I I I I I I • I I I I I I •• I I certified contract laboratory using GC/MS. A percentage of these samples may be split for analysis by a third party as deemed necessary by RES. 9.5 Reagent Checks/Calibration Standards Reagent checks and calibration standards are described in the individual analytical procedures. 9.6 Zero and Span Gasses Zero and Span Gasses are not applicable to the procedures required for this project. 9.7 Control Charts Control charts are used to assess precision and accuracy of the analyses used. Use is described in Section 12 . 27 I I I I I I I • I I I I I 10.0 PERFORMANCE AND SYSTEM AUDITS Performance evaluation samples and system auditing will be performed. Auditi11g will be conducted at least annyally by the Manager of Technical Services or a qualified consult- ant. In addition, it is anticipated that performance evalua- tion samples will be analyzed and auditing performed prior to initiation of sample testing for this project. 28 I -. I I I I I I I II I I I I I I I 11.0 INSTRUMENTS/INSTRUMENT MAINTENANCE The following spare parts are kept on hand to minimize down time: GC/FID 1. Septa and ferrules for all plumbing connections in the system. 2 • Reserve tank of compressed gas for each gas used. 3 . Reserve purification devices (at least one each; drying tube, oxygen trap, gas line filter). 4 • Injection port liner with glass, wool, and silanizing reagent. 5 • Reserve column (recommended if supplier stocks item; required if column is special order item). 6. Chart paper 7. Swagelok fittings of various sizes used. Balance 1. A second balance pH/ISE Meter 1. A second pH meter 2. Extra pH electrodes 3. Extra membrane modules and fillin solution for ammonia specific ion electrode 11.l Gas Chromatography Schimadzu GL9AM and Varian 3300 gas chromatographs equipp- ed with FID detectors (ECD detector currently not installed); capillary split/splitless injector and packed column injec- tor, microprocessor controlled. Routine maintenance includes septum replacement at least weekly (as often as daily when many samples are run); clean- ing of injector weekly; cleaning or replacement of glass 29 I I I I I I I I I I I ·I •• I injector insert weekly; column maintenance including ferrule replacement each time column is removed -ends maintained square, contaminated section removed, solvent washed as needed to maintain test mix separation; leak checks each time connection is broken in gas lines; replacement of dry- ing, oxygen traps every third tank of compressed gas; micro- processor system check (self-testing) quarterly; gas flow check each time ad justed; pressure checks daily; detectors cleaned and/or calibrated at least yearly· or when response deteriorates. Non routine maintenance is performed whenever indicated by routine quality control checks. Major repairs are performed by Schimadzu and Varian service personnel. All maintenance and repair activities and an analysis log are recorded in a separate bound notebook. Ammonia gas sensing electrode is maintained by membrane element replacement as needed to maintain normal calibration curve, and daily replacement of filling solution. Electrode is replaced as necessary. 11.2 Balances Ohaus triple beam and Ohaus Galary 110 maintenance is limit- ed to daily cleaning, leveling and calibration checks. Service is provided through a service contract with the manufacturer annually, or as needed. ed daily. Other balances are used Calibration is perform- for sample weighing to an accuracy and precision of 1% of sample weight. ance of the electronic balances is limited to light bulb replacement. Service is Mainten- cleaning, provided leveling and by qualified ifications. service technicians as needed to maintain spec- All are calibrated daily. Balance repair and calibration is recorded in a bound balance logbook. 11.3 Ovens/Constant Temperature Devices All ovens, incubators, hot plates and heating blocks/baths are monitored daily for temperature control. Routine main-30 I I I I I I I • I I I I I I tenance is normally exterior surfaces. erally replaced by defective. 11.4 Thermometers limited to cleaning Control and heating qualified service of interior and elements are gen- personnel if found All thermometers are checked quarterly for liquid column separation, cracks, defects. Calibration is performed by comparison to NBS certified or traceable thermometers. 31 I I I I I I I .. I I I I I I •• I I 12.0 ROUTINE PROCEDURES TO ASSESS DATA 12.1 Precision Precision assessed by analysis of duplicate or replicate samples. "I'' statistic is calculated according to the fol- lowing equation for duplicate samples. I., U -Bl/CA + B) The percent relative standard deviation ( RSD) is calculated for replicate samples. RSD = 100 XS where n S = Standard deviation n-1 X = Arithmetic mean value for replicates Xi= Individual values n = Number of measurements A Shewhart control chart is used to assess acceptability as described in the "Handbook for Analytical Quality Con- trol in Water and Wastewater Laboratories," USEPA 600/4- 79-019, 1979. Initially, acceptance ranges are set using values for pre- cision contained in individual method references . Only values of I or RSD resulting from samples containing five times the detection limit of analytic are used in order to avoid including data with inherently large errors. 32 I I I I I I • I I I D D I ~-I I 12.2 Accuracy Accuracy is assessed by analysis of spiked samples and con- trol samples. A percent recovery (PR) is calculated for each according to the equations below.· PR= 100 X observed value known value OR For controls PR= 100 X (observed -background) For spiked samples spike added The percent recovery is also plotted on a Shewhart Control Chart and acceptability is determined each time a spiked sample or control sample is analyzed. Initial limits are set using data for accuracy contained in the reference met- hod. Only spike concentrations at least twice the background value are used. 12.3 Biodegradation Rates Biodegradation rates are determined by plotting concentra- tions of target compounds, oxygen uptake, or biological cell growth versus time. Appropriate models such as, Monod or Haldane kinetic models for batch microbiological process- es or zero or first order kinetic decay models for soil biodegradation are applied through computer programs. Least squares line-fitting procedures are generally used and F- t est statistics are used to establish significance levels. 33 I I I I I I I • I I I I I I ~. I I 12.4 Completeness At least 90% valid in order data is that of all data generated should be verified as to make decisions during this project. Valid which is adequately documented through all phases of acquisition from sampling to reporting. 34 I .. I I I I I I I - I I I I I I •• I I 13.0 CORRECTIVE ACTION Corrective action will be initiated by James League (Manager of Technical Services, MOTEC) whenever either precision or accuracy statistics fall outside acceptance limits for any individual test or when seven consecutive statistics fall on one side of the mean value for that test. Addition-ally corrective actions will be taken whenever a performance or system audit indicates deviation from acceptable proc-edures. Such corrective actions will include: 1. Check of calculations, including preparation of standards and reagents. 2 . A rerun of the analysis in question. 3. Inclusion of additional quality control samples. 4. A step-by-step review of procedures involved in the test with the analyst. Correction of any de viations from accepted proceddures. S. Recalibration of instruments/performance check of instruments with maintenance or repair as indicated. All corrective actions will be approved by James League before data is accepted and reported. 35 -r ------'I -- ----- 3.0 QA OBJECTIVES CHART ~EASUREMENT PARAMETER REFERENCE* EXPERIMENTAL CONDITIONS PRECISION ACCURACY COMPLETENESS (METHOD) (STD.DEV.) Volatile Suspended STD Methods Aqueous phase of biologi-<+20% <+25% 90% Solids Met hod 2 09C &D cal treatments (respirome---(loss on ignition@ try, lab activated sludge 550C) simulation, field activa- ted sludge unit) to esti-mate biomass . Hoi sture STD Methods Soils analyzed for PNA to ~15% <+15% 90% Method 209F correct to dry wt. basis; Soils during biofarming+ a, to monitor water availa-bility for microbes. Polynuclear Aromatic SW-846 Soils during initial esti-<+30% <+30% 90% Hydrocarbons (PNA) Method 8100/ mation of contaminant --(Sonication extraction/ 8270 loading prior to remedia-GC/FIO analysis) (Extraction tion; Method 3550) Soils during.soil washing to verify extract ion. Soils during remediation to monitor concentrations. Polynuclear Aromatic SW-846 Aqueous extracts resulting <+30% <+30% 90% Hydrocarbons (PNA) Method 8100/ from soil washing to veri---(Liquid/liquid extrac-8270 fy PIIA extraction. tion/GC/FID analysis)· (Extraction Aqueous phase of biologi-Method 3510) cal treatments (lab simu-' lated activated sludge, field activated sludge units) to monitor PNA concentration) Continued . . . -------- ----- 3.0 QA OBJECTIVES CHART 1EASUREMENT PARAMETER REFERENCE* (METHOD) (STD.DEV.) ' EXPERIMENTAL CONDITIONS PRECISION ACCURACY COMPLETENESS Cobalt Thiocyanate STD. Methods Aqueous phase of bio-<~_30% <+30% 901 Active Substances Method 512C treated water for recycle to soil washing • . * SW-846: Test Methods for Evaluating Soli Waste. USEPA 3rd Ed. 1986 STD Methods: Standard Methods for the E amination of W, ter and Wastewater. APHA 16th Ed. 1985 I.D . + Biofarming r fers to b1odegradation ins il during lab imulation and field re ~diation -see decision dia ram ( p. ) • .. ........ .. ,·•· -··· ' I .. I I I I I I I .. I I I I I I .. I I 4.0 SAMPLING PROCEDURES 4.1 Selection of Sample Location/Number of Samples The sampling design by J. H. Exner, R. O. Gilbert and R. R. Kinnison, 1984, "A Sampling Strategy for Cleanup of Dioxin in Soil", will be used to select sampling points for verification of cleanup. This design will be modified for estimation of ini-tial contamination levels in order to identify major variations between sections of soil piles. Soils to be analyzed for nutrients, pH, and/or organics during biofarming will be sampled by compositing 7-10 uniformly spaced soil cores into single samples biweekly from each biofarming plot (if used). These samples will be used for monitoring only. Verification of cleanup levels will be performed as in the first paragraph. Samples during laboratory studies will be performed by removing single_ aliguots from well mixed media ( after phase separation if appropriate). 4.2 Sampling Procedures Soil samples will be taken from soil piles or biofarming plots following the procedure established by MOTEC. Soil samples will be taken from bottles in laboratory experiments following procedures in MOTEC labs. 4.J The table on the following page describes projected sampling and required analyses . 10 ---,,-------'I ----- ,-.. ,-.. 4.3 PROJECTED SAMPLE TYPES AND REQUIRED ANALYSIS SAMPLE DESCRIPTION MEDIUM 1 ) Composite from soil Soil to be treated 2 ) Composite from Soil treated soil 3 ) Composite from Soil treated soil 4 ) Incubator Aq. 5) Soil samples Soil ANALYSIS TO BE PERFORMED GC/FID PNA Scan GC/FID PNA Scan (MoTec) GC/MS(?) PNA Scan pH, NH3-N, PO4-P pH_ PURPOSE Estimation of initial concentration Monitoring of treatment efficiency Verification of treatment Monitoring of microbe growth and nutrient status, surfactant concentration. Monitoring biodegra- dation environment *Number of samples will depend on the rate of change for these parameters. - I I I I I I I .. I I I I I I .. I I 4.3.1 The flow diagram shown here provides an overview of the field sampling program. Laboratory experiments are sampled similarly except the ''Field Site'' is the laboratory. SAAP\.1116 Pl.AN I r'Te1Un.tlo.1 af ' I Loc.n1on >Jf sa=.,le cont11nan. - ~Qcunents, eq~1pnznt I uca.p11ng sites Orc1dd1 t fan of ~ S'-"!11 o preurv1t1cn reagents ~ Coll•ct1on •I--' I log-In ----j ~•111111~ •, t ~n" Preservation• I I £qu1pnient Storage I Deoc.ont,~infzat1on Labcr&tary Fleid Site • It not porlormad 1n tile thld 4. 4 Container material is specified in the table associated with Sections 6/7. 4 . 4 . 1 Preservationof analytical samples and holding times will be as shown in the table of Sections 6/7. Specific procedures are contained in MOTEC procedures. These procedures contain requirements for purity of reagents used and preparation of reagents if required . 4 . 4 . 2 Transport of analytical samples is generally performed 12 I .. I I I I I I I .. I I I I I I .. I I through U.S. Mails or other carrier. Samples are generally shipped in styrofoam packers and sealed. Packing material is used to reduce breakage during transport. Shipping containers are sealed or locked so that tampering will be evident when chain of custody is required. 4. 4. 3 Storage is provided in secure areas of the laboratory when required for chain of custody. All storage is located in controlled access areas. Both refrigerated and room temp- erature storage facilities are available. All samples are located under an inventory system which expedites retrieval and tracking. 4 • 5 Glass containers with teflon lined caps used for PAH samples are factory cleaned. Caps are dried in air in a clean, organic free area. All sampling equipment will be decon- taminated in the field. Other containers and equipment will be detergent and water washed. 4.6 Samples are shipped by U.S. Mail for PAH analyses. Most other analyses will be performed on laboratory samples re- quiring no shipping or will be performed in an on-site la- boratory which will be used to monitor nutrient and pH levels during field bioremedia tion. A local certified laboratory will be used for GC/MS analysis for verification of cleanup in order to reduce shipping time to same day deli very and simplify sample integrity documentation . 13 I .. I I I I I I I .. I I I I I I .. I I 4.7 The sample custody and chain-of-custody procedures contained in Exhibit B of the proposal guidelines will be incorporated into MOTEC procedures for documentation of samples. 4.8 Sample forms for recording sample history and analyses to be performed are shown in Figure 4. 8. Procedures for re- cording sample history, analyses required, field sampling conditions, etc. are found in MOTEC procedures. A listing of information required in the field sampling notebook (the listing is included in each field sampling notebook) follows the sample identification. 14 I .. I'--- pigure 4.8 MODERN TECHNOLOGY Ml. Juliet, Tc=nnc:-.!>CC: .171:?2-0J.lk Phone: h15-7.S4-9h2h I ===========s=o=1.=v=1N=c=; ·=ro=D=A=v=·=s=E=N=v=1R=o=N=~=,E=·N=T=A=t.=r=R=o=e=1.=E=M=s=w=1=r=11=1=·o=M=o=R=R=o=w=·=s=r=E=C=11=N=o=1.=u=c;=v========= I I I I CHAIN OF CUSTODY RECORD I I I I I SURVEY STATION NUMBER STATION Relinquished by: Relinquished by: Relinquished by: Relinquished by: LOCATION DATE (Signature) (Signature) (Signature) (Signature) SAHPLERS: ,signature) SAMPLE TYPE SEG. NO. OF ANALYSIS TIME Water Ail NO. CON-REQUESTED . t~omn. Grab TAINERS Received by: (Signature) Date/Time Received by: (Signature) Date/Time Received by: (Signature) Date/Time Received by lab fur field analysis: Date/Time (Signature) 1ispat.ched .. by: (Signature) 'Date/Time Received for Laboratory by: Date/Time :l_.'tet:hod of Shipment.: I 15 I " I I I I I I I .. I I I I I I .. I I 5 . 0 SAMPLE CUSTODY, Chain of custody will be established for all samples used for verification of cleanup. This procedure is described later in this document. The following procedures operation (Section 5.1 (Section 5.2 -5.2.1) will be used for field sampling 5.1.4) and laboratory operations 5 . 1 All regents are prepared by MOTEC laboratory personnel or purchased as ready for use reagents from reputable laboratory supply houses'. Documentation of reagents is performed in a bound notebook which includes all relevant data on the preparation of source of each ingredient. Information re- corded used, includes; reagent name, identity and weight of procedure for all ingredients, which lot it is number and supplier for each ingredient, diluent or solvent, final volume, initials of preparer, and date and time of prepara- tion. Each reagent so prepared is labelled with reagent name, date prepared, initials of preparer, and page in rea- gent log on which documented. 5.1.1 Field Log Book All information pertinent to a field survey and/or sampling must be recorded in a log. This is a 3-ring binder to hold DAILY JOB REPORTS. 21.6 by 27.9 cm (8-1/2 by 11 in.). Entries in the log book must include at least the following: 0 Purpose of sampling (e.g., surveillance, contract number) 0 Location of sampling point . 0 Name and address of field contact. 0 Producer of waste and address if different than location. 16 I .. I I I I I I I .. I I I I I I .. I I 0 Type of waste (e.g., sludge, wastewater) . 0 Suspected waste composition 0 Number and volume of sample 0 Description of sampling methodology. 0 Date and time of collection. including concentrations. taken. point and sampling ° Collector's sample identification number(s). 0 Sample distribution and how transported (e.g., name of laboratory, UPS, Federal Express). 0 Reference aids such as maps or photographs of the sampling site. ° Field observations. 0 Any field measurements made (e.g., pH, flammability, explosivity). Sampling situations vary widely. No general rule can be given as in the to the extent of information that must be entered log book . A good rule; however, is to record sufficent information so that someone can reconstruct the sampling without reliance on the cbllector's memory. 5. l. 2 Sample preservations to be used are specified in Section 6. 0. Preservation is performed according to MOTEC proce- dures. Each sample container is checked at log-in for pre- servation. Field samples collected by MOTEC will be pre- served in the field at the time of collection and will be documented in the field sampling log book. All samples received by MOTEC will also be checked for proper preserv- ation. Each sample will be labelled (with a color coded label containing the initials of the technician who preserved the sample) on the sample identification tag. A log of sample preservations will be maintained at the log in area . 17 I " I I I I I I I .. I I I I I I •• I I 5 .1. 3 Standard MOTEC labels shall be attached to each sample. 5.2 MOTEC personnel authorized to act as sample custodians are Chris Irwin and Jonathan White. Sample custodians shall accept responsibli tiy for documentation and proper sa1aple handling of all samples received. 5.2.l A Lab Tracking Form will be prepared for each sample at log in. This form will be maintained by the sample custodian and filed in the project file upon completion of all testing. All samples shall remain in the custody of the sample cus- todian unless checked out by a technician for analysis . Technicians shall retain custody until returned to the sample custodian following analysis. 18 I .. I I I I I I I .. I I I I I I .. I I 6.0 CALIBRATION PROCEDURES AND FREQUENCY Procedures to be followed for calibration is listed below as the frequency of recalibration. Calibration standard sources are listed in the table. Any preparation details, lot numbers, dilutions, etc. are detailed in the reagent log book maintained in the laboratory. Recalibrations are documented in the instrument log books with reference to the reagent log book for all standards used. Analyte: Sample Type: Ref. Source: Ref. Number: Method Description: Container: Preservation: Max. holding time Calibration Frequency: Calibration Standard PNA Extract Soil/Solid Waste SW 846 3550 Sonication Extraction G:Teflon, lined caps Cool, 4 ° C 28 Days NA NA 19 I ~ I I I I I I I • I I I I I I ~ I I 7.0 ANALYTICAL METHODS All analytical methods to be used are referenced in SW 846 and MOTEC Procedures. 20 I " I I I I I I I 18 I I I I I I •• I I 8.0 DATA REDUCTION, VALIDATION AND REPORTING 8.1 PAH MOTEC GC procedure is used to generate analytical values for the concentration of 16 individual PNA coumpounds, in- cluding benzo(a)pyrene, in solvent extracts of soil or water. The result is generated in mg/1 by the following calculation which is performed by the GC microprocessor: A(mg/1) = B (mg/1) x C x D E F A = Concentration in extract B = Concentration of standard C = Peak area of sample D = Peak area of IS E = Peak area of standard STD F = Peak area IS IS = Internal standard in sample added during s extraction IS = Internal standard in PAH mixed standard STD Results for all aqueous samples will be reported in mg/1 calculated as follows: A(mg/1) = B (mg/1) x 1000 x C(ml) x F D(ml) A= Sample concentration B = Concentration in extract C = Volume extracting solvent D = Volume sample extracted where F = Concentration or dilution factor for extraction solvent prior to injection in GC 21 I •• I I I I I QAPP 'I I .. I I I I I I ; .. I : I I I I I I I .. I I I I I I .. I I Approvals QA PROJECT PLAN SANDOZ CHEMICALS SODYECO SITE MT. HOLLEY, NORTH CAROLINA Prepared by: MOTEC, INC. Project Manager -MOTEC 99 Mt. Juliet P.O. Box 338 Mt. Juliet, TN QA Manager -MOTEC Project Officer QA Officer -EPA 1 Road 37122 .• I .. I I I I I I I .. I I I I I I .. I I SECTION 1.0 2. 0 3.0 4. 0 5.0 6. 0 7.0 8. 0 9.0 10.0 11. 0 12.0 13.0 14.0 COPIES TO: TABLE OF CONTENTS INTRODUCTION Project Description Project Organization and Responsibilities QA Objectives Sampling Procedures Sample Custody Calibration Procedures and Frequency Combined Analytical Procedures Data Reduction, Validation and Reporting Internal Quality Control Checks and Frequency Performance and System Audits and Frequency Preventive Maintenance Procedures and Schedules Specific Routine Procedures Corrective Action Quality Assurance Reports to Management PAGE John Bogart Project Manager -MOTEC Senior Environmental Engineer Project Officer/MOTEC J. Paige Straley, P.E. QA Officer/EPA 2 I .. I I I I I I I .. I I I I I I .. I I Name Chris Irwin John Bogart Chris Irwin James League James League Sam Wood Delane Dacus Key Individuals List Title/Function QA/QC Manager Project Manager Project Laboratory Manager Project Analytical Supervisor Project Field Services Manager Project Engineering Manager Project Administrator 3 I .. I I I I I I I .. I I I I I I .. I I 1.0 PROJECT DESCRIPTION This project involves bioremediation of solvent and PAH contami- nated soil. The process selected for remediation is designed to remediate the contaminants in situ by introducing a high biomass inoculant directly onto the soils and aerating via a tractor driven rototiller. The target components will be reduced to ARAR levels as defined by the EPA. Analytical data will be used to assess: 1) nutrient status dur- ing all biological degradation phases, 2) PAH and sol vent target compounds in soil, and 3) biomass concentrations during biological incubation. All data except PAH analyses for final verification of concentrations in residual soil will be produced by MOTEC and used by MOTEC to optimize and control operations during re- mediation. Verification data to document that cleanup goals have been attained will be provided by laboratory qualified under the EPA CLP program and also certified in the state of North Carolina . 4 I .. I I I I I I I ID I I I I I I .. I I INTRODUCTION The Quality Assurance Project Plan which follows addresses the elements of the quality assurance program which will impact dir- ectly or indirectly on the quality of data generated during this project. Some of the data generated will be used for making decisions where differences are large and obvious (thus requiring less precision and accuracy). Other data will be used to make decisio- ns where differences are expected to be small, thus maximizing the importance of accuracy and precision. Test methods and sam- pling plans have been selected to comply with the requirements of the end use. Documentation of all procedures is stressed so that evaluation of the data will allow accurate decision making during this and future projects based on the work performed. 5 --r --- PROJECT SCIENCE I- . ADVISORY BOARD QA/QC MANAGER . ------ THE MOTEC TEAM SANDOZ CHEMICALS -SODYECO SITE PROJECT ORGANIZATION CHART PROJECT ----,r ADVISORS --. ADMINISTRATOR ------LEGAL PROJECT MANAGER I PROJECT ENGINEERING MANAGER I PROJECT LABORATORY MANAGER PROJECT ANALYTICAL SUPERVISOR ACCOUNT IN INSURANCE RISK ASSE SAFETY I G SSMENT - PROJECT FIELD SERVICES MANAGER --r ------'I -- -----, 3.0 QA OBJECTIVES CHART iE!\SUREMENT PARAMETER REFERENCE* EXPERIMENTAL CONDITIONS PRECISION ACCURACY COMPLETENESS (METHOD) (STD. DEV.) pH SW-846 Soils initially (before <1-0.3 pH units <+0.3 units. 90% (electrode) Method 9045 remediation) and during - biofarming+ if required. STD Methods Water during biological c::_O. 2 pH units <+0.2 units Method 423 processing. · - Arrrnonium-N STD Methods Water during biological <;!_20% <+20% 90% (electrode) Method 417 processing. -.J Soils (extraction with 2N KCl) during biofarming+ -. if required. Ph'.lsphate-P STD Methods As for a1M10nium-N, except <+20% <:_20% 90% (stannous chloride] Method 424B soils are extracted with molybdate colori-Bray P, solution prior to metricj analysis. COD SID Methods Aqueous phase of soil <+20% <+20% 90% (block digestion/ Method 508C washing simulation in dichromate colori-laboratory. Used as metric) rapid gross measure of relative extraction efficiency. Continued . I •• I I I I I I I .. I I I I I I .. I I 5 prefinal/final inspections. At the approximately 95% project completion stage, a final inspection meeting may also be held. The "Prefinal Inspection Report" and the final inspection report ( "Remedial Action Report") will be made in accordance with the "Superfund Remedial .... Guidance", sections 3.4.2.3 and 3.4.3.3. These reports will be forwarded to the EPA project officer. I .. I I I I I I I .. I I I I I I .. I I I •• I I I I I I I 118 I I I I I I .. I I OPERATION AND . MAIIJ"TcNAMCE 'PLAIJ I •• I I I I I I I .. I I I I I I I f I SANDOZ CHEMICALS PREFINAL/FINAL DESIGN OPERATION AND MAINTENANCE PLAN { OP ,-fv'lfi/N) The proposal of work and submitted by MOTEC, design parametars. INC. outlines the To summarize, MOTEC scope will construct a berm surrounding area C. The berm will control run-off and runon water. The treatment area will be sloped to a concrete sump. The interior of the bermed area will be circumscribed with a drainage ditch to further enchance drainage of the treatment area. Since activities inside the berm will decrement the eleva- tion, the original berm height will be 18-24 inches. This will suffice normal operation for the duration of the pro- ject . The contaminated area will be deep plowed to approximately 12 inches deep. This area will then be inoculated with a high biomass irrigant. As soon as applicable, the area will be aerated by a tractor driven rototillar. The aeration -irrigation/inoculation cycle will be repeated 2 or 3 times per week. The irrigant will be incubated in two 20,000 gallon moble tanks, operated at a 15,000 gallon working capacity. The cultured acclimated bacteria 1·1ill be grown in a nutrient rich, aerated broth. Soi 1 pH enhancements, if required, will be delivered via the broth. MOTEC personnel will operate the site. They have technical training appropriate to this project and have 40 hours of h~alth and safety training as required by OSHA. Standard ope~ation and maintenance will consist of tilling/ aeration of the tratment area, irrigation/inoculation, and recharging the incubation chambers. This will occur between 1 I •• I I I I I I I 18 I I I I I I I f I two and three times per week. Additional aeration or manipulation of the material will be accomplished by plow and/or disc harrow. MOTEC projects a 4-6 week treatment period for the dectected contaminants. A volume of 1300 yd' in each lift is calcu- lated from Sandoz' s specifications. This will require five lifts for the approximately 6000 yd' to be decontaminated. This leads to a 20-30 week treatment period, excluding wea- ther contingencies. MOTEC has proposed to treat a minimum of 6000 yd' for $119,280.00. This will be charged as the work is performed. POTENTIAL OPERATING PROBLEMS Potential Operating Problems are only mechanical problems with aerator/tilling equipment, water pumps, and aerators in the incubators. These will be repaired by field personnel when possible. Local electricians and/or mechanics will be utilized to handle major problems. Biogeneration is an established protocol and no difficulties are for seen. The bacteria do not breakdown, wear out, or go on strike. All they require is adequate nutrition, oxygen, and reasonable temperatures. Two weather conditions which will impede operations are excess moisture and ·cold temperatures. The treatment area is bermed to preclude run-on and sloped, ditched, and sumped to enhance drainage and removal of excess water. This water will be returned, whenever possible, to the incubator. If the treatment area ever becomes inundated with water the biological action will be curtailed. Tl1e bacteria used by MOT EC have the capability to use nitrate ions in the 2 I •• I I I I I I I .. I I I I I I I f I soil as an albeit at a high nitrate oxygen source and thus operate anaerobically, low kinetic rate. Therefore, MOTEC will add levels to the initial inoculations to insure adequate levels in the event the system become anaerobic. Low temperatures present a complication which can only be overcome by patience and the vernal equinox. Very low rates of success or kinetic degradation are achieved between De- cember and February. ROUTINE MONITORING Monitoring will be an on-going process throughoL1t the pro- ject. Tests will be conducted to ascertain biological acti- vity, acidity of the soil, nutrient levels in the incubator, and contaminant levels in the soil. Biological activity in the incubator will be ascertained before each inoculation . This is monitored by a Dissolved Oxygen Uptake Rate (DOUR) determination. and stirring probe will be used. An oxygen meter The actual numbers of bacteria in the inoculum will be mea- sured monthly by sending a sample to the manufacturer. An exact culture count will be performed and reported. The incubator liquor will be monitored for nutrient levels and pH. If soil pH levels demand adjustment the pH of the irrigant will be altered accordingly and this liquor will carry the caustic to the soils. (NOTE: Soi ls usually become acidic, requiring a basic adjustment). LABORATORY TESTING Finally, the level of contaminant will be monitored on a biweekly schedule. A baseline level determination will 3 I •• I I I I I I I .. I I I I I I I ,, I be made by a systematic grid sampling after the initial plowing. The approximately 2 0 0 x 2 0 0 treatment area will have 4 systematically spaced samples taken, and analyzed by GC/FID. composited, Every two weeks a new composite will be taken and analyzed. When the internal analysis shows that treatment levels have been attained, an independent lab will do verification sam- pling and analysis. (Internal QA/QC procedures will be delineated in the QAPP document). Upon verification of decontamination, the soil will be re- moved and stock piled. The treatment area will then be deep plowed and the second and subsequent lifts will be treated. EQUIPMENT The equipment required will include a tractor with rototil- ler, disc, and plow. The bioacti vi ties wi 11 utilize incu- bater tanks, aerators, water pumps, and irrigation equipment. The excavation/soil relocation will be done by front end loader, bulldozer, and possibly dump truck, depending upon location of "treated" stockpile. The bulldozer will con- struct the diversion-containment berm. RECORDS A daily operating log activity. A sample is will be maintained for each day's included as Figure 1. A copy will be maintained by operating personnel, one given to Sandoz officials, and one sent to MOTEC'S Mt. Juliet office. This log will delineate the total site activities. Lab records are outlined in the QA/QC document. 4 I I . • I 0' I I I I I I I I I I I I t I FIGURE 1 ____________________ DATE. _______ TIME. _______ _ SUPERVISDR/TECHNICIAN. ___________ W.EATHER TEMP _______ _ EMPLOYEES HRS. WORK PERFORMED i ' U1 ' w I w I >-D ...J [¼ : w ' I -I ADDITIONS TO REACTOR/LANDFARM/DRYING BED/OTHER 1 i 2 3 I 4 5 6 i I ' ' BACTERIA I ' ! __, ' a: FERTILIZER ' i ..... ' re w. EMULSIFIER ' ! I-'•) ; : a: i :.: : SODA ASH I ' i ' . ' : MANURE ! ' ' · MOLASSES i ; i ' Y03 SLUDGE/SOIL I I ' I . : i ; : MAKE-UP WATER ' ' ' ! ' PUMPING SEQUENCE ' ' i ' LANDFARM WATER ] : : ' U1 ' i I ' ' ,__ z BEFORE-DEPTH ' I I w ' : :.: [ w. LENGTH ' i re : ::, . U1 . WIDTH I I a: : : I w, i I :.: : AFTER-DEPTH ' I ' ' LENGTH ' ! ' I i WIDTH i ' i ! ' ' I BACTERIA I K-001 ! u I O' PERCENT MOISTURE ...... a: 0 DOUR I ' ' nH I I f I I I I I I b I I I I I I I • I I Emergency procedures are delineated in Health and Safety Plan developed for Sandoz by MOTEC. 5 I ~ . .: ,. ·•'-· I I Lt$T I OF I Re-S'PON s E" s I I I ~ I I I I I I '-t· I I I ~ I I I I I I I I I I I I I LIST OF RESPONSES FROM "SUPERFUND REMEDIAL DESIGN AND REMEDIAL ACTION GUIDANCE" -OSWER DIRECTIVE 9355.0-4A 1. Plans and Specifications These are covered in the "Groundwater Recovery Systems Work Plan" by Law Environmental and "Prefinal/Final Design" prepared by MoTec, Inc. 2. Offsite RCRA Facilities No recovered groundwater or soil residues will be removed from the Mt. Holly Plant site. Groundwater will be pumped to the onsite waste water treatment facility. In the case of area C, the treated soil will be stockpiled in an area that is as close as practical to the treatment area. When work is finished at the treatment area, the stockpiled material will be replaced in the area from which it was excavated. In the case of area D, the soils cannot be placed back in their original positions because of problems with the steep slopes involved. Clean fill from Sandoz' onsite borrow area will be used to replace the excavated soil. Once the contaminated soil is cleaned to the ARAR specified in the ROD, it is Sandoz' understanding that the soil can be utilized as 'fill. It is our intent to drain the treated soil and then use it as a part of the pre-load cover that is being applied to the former gypsum lagoons, Z02 and Z02B. Even though this soil will have been treated to the ARAR standard, we consider that it is good practice to use it in an area that will be controlled and monitored. 3. Compliance with the Requirements of Other Environmental Laws Section 6.6 of the ROD gives a list of environmental laws and comments on their applicability. In the following paragraphs, each of these laws is further addressed: Resource Conservation and Recovery Act As discussed in the ROD, the recommended remedy will be incorporated into Sandoz' RCRA Part B permit. Area D soils will be treated with a soil washing/biological treatment system, rather than incineration. Treatment will be to ARAR standards. No soil materials will be removed from the Mt. Holly site. Clean Water Act Recovered groundwater and effluent from soil washing (area D) and from the bio-remedial at area C will be I I I I I I .. I I I I I I .. I I 2 directed to the wastewater treatment plant (WWTP). Water discharges from soil treatment are low-volume, as much of the treatment water is recycled. Only "blowdown" or extraordinary amounts of rainwater will be discharged to the WWTP. Discharge of waters to the WWTP is a part of treatment schemes endorsed by EPA in the ROD. The WWTP has been shown to provide adequate treatment. Floodplain Management Executive Order 11988 The CERCLA areas do not lie within a floodplain and thus are not subject to the requirements of E.O. 11988. Department of Transportation No materials will leave the Sandoz/Mt. Holly site. DOT regulations are not applicable. Occupational Safety and Health Administration A "Site Safety Plan" has been developed by Sandoz' contractor (MoTec, Inc.) in order to demonstrate our conformance to all applicable safety rules, including OSHA and the Sandoz Chemicals Safety Procedure policy. Please refer to the appropriate sections of the "Prefinal/Final Design" document for further details . Safe Drinking Water Act The cleanup will meet the goals of the SDWA since the Maximum Contaminant Levels (MCL's) were used in determining the ARAR limits, National Pollution Discharge Elimination System Please see the relevant comments under the Clean Water Act. Endangered Species Act The Sandoz Mt. Holly Plant is an industrial site. We believe that no endangered or threatened species inhabit sites A-D. Site Eis a portion of an abandoned farm field and could possibly afford wildlife habitat. However, activity here will be confined to drilling a few wells, and so the disturbance will be minimal and temporary. Less than an acre will be affected in area E. Sandoz has contacted the U.S. Fish and Wildlife Service for their professional determination . We also point out that the U. S. Fish and Wildlife Service endorsed the draft ROD in a letter dated September 16, 1987. This letter was included as an attachment to the final ROD. I I I I I I p I I I I I I I 3 Ambient Air Quality Standards At sites A, Band Ethe cleanup will proceed essentially by pumping contaminated groundwater to the wastewater treatment plant (WWTP). Although some air stripping is inevitable, the indicator compounds have been shown to degrade in the WWTP. The small quantities stripping from the WWTP will not contravene Ambient Air Quality Standards. At sites C and D the contaminated soils will be tilled. Most of the indicator compounds sorb well to soil, and we predict very small releases to the atmosphere. Contraventions of Air Quality Standards should not occur. Sites C and D will be monitored during the early phases of the project to assure that Air Quality Standards are not violated. A report will be filed to the EPA project officer. State Drinking Water Standards Please refer to the comments under "Safe Drinking Water Act". 4. Equipment Startup and Operator Training MoTec will provide trained, experienced operators for their systems at areas C and D. In sections 6.1 -6.3 of the Site Safety Plant in the "Prefinal/Final Design", health and safety training is specifically discussed. 5. Operator and Maintenance (OP+ MAIN) Plan This is fully discussed for soil treatment in the relevant portion of MoTec's "Prefinal/Final Design" document. The groundwater recovery system will be inspected monthly with appropriate maintenance as needed. 6. Quality Assurance Project Plan (QAPP) This is fully discussed in the relevant portion of MoTec's ''Prefinal/Final Design" document, and in the Groundwater Recovery Systems Work Plan 7. Major Design Changes The change to a biological treatment for area C is a major change. However, as discussed in Mr. Patrick Tobin's letter of June 6, 1988, Sandoz was given approval to study biological treatment as a potentially acceptable remediation technique. Based on our investigations, we believe that this method will bring the contaminant levels I .. I I I I I I I .. I I I I I I .. I. I. 8. 4 at the site to well below the ARAR's. It will conform to the goals of reduction of mobility, volume, and toxicity by in situ bacterial degradation of the organic contaminants. In area D we have gone to a soil washing/biotreatment option. This is superior to hauling to an incinerator as no offsite movement of materials takes place. This conforms to the goal of reducing the mobility of the materials, as well as eliminating the possibility of incidents during transportation and processing. The surfactant/biotreatment process will bacterially degrade the organic contaminants, thus conforming to the goals of reduction of volume and toxicity. We also point out that soil washing was an approved technique as called out in the ROD. Community Relations As discussed in the ROD, there were no additional public concerns left unresolved. Therefore, Sandoz will limit its community relations efforts to the following actions: Fact sheets will be written and made available to individuals expressing an interest in the project. These fact sheets will be updated as appropriate as the project progresses • Contacts will be made with key public officials to inform them of project status. Sandoz will respond to inquiries as they occur. The EPA project officer will be copied on all such responses. 9. Construction Inspection 10. It is understood that Sandoz will have the primary responsibility for this item. Sandoz will maintain inspection oversight on a regular basis throughout the project. Progress Reports Progress reports will be prepared monthly during soil treatment and well construction and forwarded to the EPA project officer. These reports will be made according to the format in the "Superfund Remedial. • . Guidance" (3.3.2) • 11. Prefinal and Final Inspections An inspection meeting will be held at EPA's discretion upon mobilization of equipment to the site for areas C and D soil treatment. Areas A, B, and E will have separate