HomeMy WebLinkAboutWS-9333_44564_CA_CAI_20210901_FS-EmailFrom:rbshah To:Lepard, Mindy Subject:Re: [External] 44564 - Eagle Mart 2 - Corrective Action Feasibility Study Date:Wednesday, September 1, 2021 5:56:36 PM CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Mindy, Sorry for the delay. Please see below for the response to your questions. If you have any further questions or need additional information, please call/email me. Thanks. Raj Raj B. Shah, P.E., LEED®APTechnical DirectorAgra Environmental, Inc.P.O. Box 5611Cary, North Carolina 27513Office: (919) 858-5350 Ext. 101Mobile: (919) 622-1155Fax: (919) 858-5351rbshah@agraenvironmental.com From: "Lepard, Mindy" <mindy.lepard@ncdenr.gov> Date: Tuesday, July 13, 2021 at 3:32 PM To: "rbshah@consultechenv.com" <rbshah@consultechenv.com> Subject: FW: [External] 44564 - Eagle Mart 2 - Corrective Action Feasibility Study Raj, I just sent this email to Aaron Springer and saw that he left the company. I copied you on that email but see that it may be an old address so I thought I’d send this to you at the email address in Aaron’s automatic reply to make sure you get it. I apologize if you are receiving it twice. The Corrective Action Branch and Trust Fund Branch met last week to review the recommendations in the Feasibility Study Report. We have a few questions and suggestions from the report before we all meet to discuss the remedial strategy. What is the depth of the injections? The depth of the injections is outlined in the feasibility study in section 9. On injections near MW-1, MW-2, and MW-6 the target treatment zone is 15’-35’ and near MW- 10 the treatment zone is 12’-32’. The PRB injection depth will be between 10’-30’. What was the radius of influence of the injections from the pilot study? Not available as there are no other monitoring wells/points in the immediate vicinity of MW-2 that we could have used during the pilot test. Based on our past experience and as a rule of thumb 5 to 7 feet is a good estimate of the radius of influence of each injection point. How did you arrive at 12,780 pounds of Klozur CR? Klozur-CR Estimate for Graham, NC Site Area Number of IPs KCR, lbs per IP Volume of 20% KCR slurry per point, gal Total Mass of KCR, lb Total KCR Slurry, gal MW-1 16 270 146 4,320 2,336 MW-2 6 270 146 1,620 876 MW-6 6 270 146 1,620 876 VEW-1 1 270 146 270 146 MW-10 12 225 122 2,700 1,464 RB 10 225 122 2,250 1,220 otal 51 12,780 6,918 Would it be better to install another monitoring well between MW-10 and MW-12 before putting in the reactive barrier to better define the amount of contamination in that area? As MW-12 is known to be contaminated, we do not recommend installation of an additional well between MW-10 and MW-12. It is, however, recommended that a shallow monitoring well (MW-16) be installed along the southern property edge. Additionally, a new vertical extent well (VEW-3) should be installed near the property edge in line with the source area and SW-2 Could you conduct a packer test on SW-2 to test where the MTBE may be coming into the well? Maybe pack off below 90 feet and collect a sample. A packer test would not be an option for SW-2 since it is an open borehole well with extremely fractured (vertical and horizontal) rock. There would be no way to isolate zones with no communication from other depths. We will schedule a meeting when you’ve had time to look over these questions and are ready to discuss the remedial strategy. Let me know if you have any questions and the timeframe that you think you’ll need. Thanks, Mindy  ------------------------------------** Important Message**------------------------------------------------------------------Until further notice, all UST Section “deliverables/documents” (letters, reports, recorded NRPs etc.) must be submitted electronically to the appropriate Incident Manager (See below for County Assignments and Contact Information).  If a document is too large to send via email, please upload the document onto the Division of Waste Management FTP site. Follow the upload with an email notifying the Incident Manager of the document’s presence on the FTP server.  Contact the appropriate IncidentManager for FTP instructions. Please provide a responsible party email address with each submittal, if available. COUNTY ASSIGNMENTS (Subject to Change. Check List Frequently): Guilford County: Gene Mao (336-641-3589) Ashley Dinkins (336-641-5557) Christina Schroeter: Ashe and Forsyth (336-776-9683) Mindy Lepard: Alamance and Surry (336-776-9686) Linda Estkowski: Caswell, Davie, Rockingham, Stokes, Watauga, Yadkin (336-776-9680) Doug Whitmire: Allegheny, Davidson, Randolph, Wilkes (336-776-9685)Karen Hall: All counties and phases through an LSA, Complaints and Spills (336-776-9681)Shelia McIntosh: File Reviews (336-776-9630) ALL UST ARCHIVED FILES CAN BE FOUND ON THE FOLLOWING LINK:https://deq.nc.gov/about/divisions/waste-management/laserfiche DWM LOCATOR TOOL: USE MAP FOR LOCATING UST SITES ACROSS THE STATE: https://ncdenr.maps.arcgis.com/apps/webappviewer/index.html?id=7dd59be2750b40bebebfa49fc383f688UST FACILITY DABASE (Facility Permitting and Inspection Documents):https://xapps.ncdenr.org/wm/docs/WMDocs_Search.jsp From: Aaron D Springer <aspringer@consultechenv.com> On Behalf Of aspringer@agraenvironmental.com Sent: Friday, May 7, 2021 1:49 PM To: Lepard, Mindy <mindy.lepard@ncdenr.gov> Cc: rbshah@agraenvironmental.com Subject: [External] 44564 - Eagle Mart 2 - Corrective Action Feasibility Study CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Mindy, The Corrective Action Feasibility Study for Incident #44564 Eagle Mart 2 has been uploaded to the CAB WS FTP file folder. Thank you, Aaron D. SpringerEnvironmental ScientistAgra Environmental, Inc.P.O. Box 5611Cary, North Carolina 27512Mobile: (336) 596-1350Office: (919) 858-5350Fax: (919) 858-5351aspringer@agraenvironmental.com