Loading...
HomeMy WebLinkAboutWS-9333_44564_CA_CAI_20210713_FS-EmailFrom:Lepard, Mindy To:rbshah@consultechenv.com Subject:FW: [External] 44564 - Eagle Mart 2 - Corrective Action Feasibility Study Date:Tuesday, July 13, 2021 3:32:00 PM   Raj,   I just sent this email to Aaron Springer and saw that he left the company. I copied you on that email but see that it may be an old address so I thought I’d send this to you at the email address in Aaron’s automatic reply to make sure you get it. I apologize if you are receiving it twice.     The Corrective Action Branch and Trust Fund Branch met last week to review the recommendations in the Feasibility Study Report. We have a few questions and suggestions from the report before we all meet to discuss the remedial strategy.   What is the depth of the injections? What was the radius of influence of the injections from the pilot study? How did you arrive at 12,780 pounds of Klozur CR? Would it be better to install another monitoring well between MW-10 and MW-12 before putting in the reactive barrier to better define the amount of contamination in that area? Could you conduct a packer test on SW-2 to test where the MTBE may be coming into the well? Maybe pack off below 90 feet and collect a sample.   We will schedule a meeting when you’ve had time to look over these questions and are ready to discuss the remedial strategy. Let me know if you have any questions and the timeframe that you think you’ll need.   Thanks, Mindy     ------------------------------------** Important Message**------------------------------------------------------------------ Until further notice, all UST Section “deliverables/documents” (letters, reports, recorded NRPs etc.) must besubmitted electronically to the appropriate Incident Manager (See below for County Assignments and ContactInformation).  If a document is too large to send via email, please upload the document onto the Division of WasteManagement FTP site. Follow the upload with an email notifying the Incident Manager of the document’s presenceon the FTP server.  Contact the appropriate Incident Manager for FTP instructions. Please provide a responsibleparty email address with each submittal, if available. COUNTY ASSIGNMENTS (Subject to Change. Check List Frequently): Guilford County: Gene Mao (336-641-3589) Ashley Dinkins (336-641-5557) Christina Schroeter: Ashe and Forsyth (336-776-9683) Mindy Lepard: Alamance and Surry (336-776-9686) Linda Estkowski: Caswell, Davie, Rockingham, Stokes, Watauga, Yadkin (336-776-9680) Doug Whitmire: Allegheny, Davidson, Randolph, Wilkes (336-776-9685) Karen Hall: All counties and phases through an LSA, Complaints and Spills (336-776-9681) Shelia McIntosh: File Reviews (336-776-9630) ALL UST ARCHIVED FILES CAN BE FOUND ON THE FOLLOWING LINK: https://deq.nc.gov/about/divisions/waste-management/laserficheDWM LOCATOR TOOL: USE MAP FOR LOCATING UST SITES ACROSS THE STATE: https://ncdenr.maps.arcgis.com/apps/webappviewer/index.html?id=7dd59be2750b40bebebfa49fc383f688UST FACILITY DABASE (Facility Permitting and Inspection Documents): https://xapps.ncdenr.org/wm/docs/WMDocs_Search.jsp   From: Aaron D Springer <aspringer@consultechenv.com> On Behalf Of aspringer@agraenvironmental.com Sent: Friday, May 7, 2021 1:49 PM To: Lepard, Mindy <mindy.lepard@ncdenr.gov> Cc: rbshah@agraenvironmental.com Subject: [External] 44564 - Eagle Mart 2 - Corrective Action Feasibility Study   CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam.   Mindy,   The Corrective Action Feasibility Study for Incident #44564 Eagle Mart 2 has been uploaded to the CAB WS FTP file folder.   Thank you, Aaron D. SpringerEnvironmental ScientistAgra Environmental, Inc.P.O. Box 5611Cary, North Carolina 27512Mobile: (336) 596-1350Office: (919) 858-5350Fax: (919) 858-5351aspringer@agraenvironmental.com