Loading...
HomeMy WebLinkAbout6301_MooreCounty_MSWLF_CDLF_March2023LFG_FID1787013_20230413I PENR USE ONLY I I ❑Paper Report [:]Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: • Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): S&ME, Inc. (on behalf of Moore County) Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Edmund Q.B. Henriques E-mail: ehendques@smeinc.com Phone: 336-288-7180 NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or. 1600) October 20-24, 2006) March 28, 2023 Moore County Landfill 456 Turning Leaf Way, Aberdeen, NC 63-01 .0500 Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring �z Detection Monitoring Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑x Groundwater monitoring data from private water supply wells Leachate monitoring data Surface water monitoring data X Methane gas monitoring data Corrective action data (specify) Other(specify) Pilot Test Well Methane Data Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. �z Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Edmund Q.B. Henriques, PG Senior Geologist, S&ME Inc. 336-312-3330 Facility Representative Name (Print) Title (Area Code) Telephone Number I,— n A 4/11/2023 Affix NC Licen%gjVjIW4„jsional Geologist Seal Signature I N f Date 8646 W. Market Street, Suite 105, Greensboro NC 27409 Facility Representative Address F-0176 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 fr z�G ^�CFdL 00�� spay. _ �• ®. NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: March 28, 2023 NC Landfill Rule (.0500 or.1600): 0.0500 Sample Collector Name & Position: Ed Henriques / Senior Geologist, S&ME, Inc. Gas Meter Type & Serial Number: GEM 5000 Plus / SN G506450 Gas Meter Calibration Date: 8/23/2022 Field Calibration Date & Time: 3/23/2023 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 04/2027 Gas Meter Pump Rate: 693 cc/min Ambient Air Temperature: 70 F Barometric Pressure (in. or mm Hg): 29.52 Weather Conditions: Sun Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) Initial % LEL Stabilized % LEL % CH4 � volume � % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES GP-9 60 1151 120 0 0 0.0 20.0 0.7 0 Property Boundary Monitoring Point G P 10 R 60 1158 120 0 0 0.0 18.2 2.4 0 Property Boundary Monitoring Point 1 GP-1 1 60 1206 120 0 0 0.0 15.6 3.8 0 Property Boundary Monitoring Point G P-12 60 1 230 120 0 0 0.0 20.1 0.6 0 Property Boundary Monitoring Point GP-1 3R 60 1240 120 0 0 0.0 19.8 1.1 0 Property Boundary Monitoring Point G P-14 R 60 1247 120 0 0 0.0 18.1 2.4 0 Property Boundary Monitoring Point GP-1 5R 60 1 255 120 0 0 0.0 20.4 0.6 0 Property Boundary Monitoring Point G P-16 60 1303 120 0 0 0.0 8.3 13.1 0 Property Boundary Monitoring Point GP-1 7 60 1311 180 58 58 2.9 0.7 14.5 0 Property Boundary Monitoring Point G P-18 60 1341 180 > 100 > 100 38.7 2.1 26.5 0 Property Boundary Monitoring Point G P-19 60 1326 120 0 0 0.0 17.9 4.0 0 Property Boundary Monitoring Point NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1% by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Senior Geologist / S&ME, Inc. SIGNATURE TITLE Revised - March 6, 2017 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are 'Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: Moore County Landfill Permit Number: 63-01 Sampling Date: March 28, 2023 NC Landfill Rule (.0500 or. 1600): 0.0500 Sample Collector Name & Position: Ed Henriques / Senior Geologist, S&ME, Inc. Gas Meter Type & Serial Number: GEM 5000 Plus / SN G506450 Field Calibration Date & Time: 3/23/2023 Gas Meter Calibration Date: 8/23/2022 Field Calibration Gas Type (15115 or 35/50): 15/15 Field Calibration Gas Canister Expiration Date: 4/2027 Gas Meter Pump Rate: 693 Ambient Air Temperature: 70 F Barometric Pressure (in. or mm Hg): 29.52 Weather Conditions: Sun Instructions: Under "Location or LFG Well", list monitoring well # or describe monitoring location (e.g., inside field office). Attach a test location map or drawing. Report methane readings as both % LEL and % CH4 by volume. Convert % CH4 (by volume) to % LEL as follows: % methane (by volume)/20 = % LEL. *Hydrogen Sulfide (H2S) gas monitoring may be required for Construction & Demolition Landfills (CDLFs). See individual permit conditions and/or Facility LFG monitoring plan. Location or LFG Well ID S ample Tube Purge Time of Day Time Pumped (sec) initial /o LEL Stabilized /o LEL % CH4 (volume) % 02 (volume) % CO2 (volume) % H2S* (volume) NOTES MW-6 60 1320 180 >100 >100 6.9 15.6 5.2 0 not a compliance point GV-33 60 1348 180 > 100 >100 35.7 1.8 30.4 0 Passive vent, not a compliance point GV-34 60 1355 180 >100 >100 49.8 0.1 37.4 0 Passive vent, not a compliance point GV-35 60 1403 180 >100 >100 26.4 9.9 19.6 0 Passive vent, not a compliance point GV-36 60 1410 180 >100 >100 46.7 3.4 33.4 0 Passive vent, not a compliance point Maintenance Shop 60 1222 120 0 0 0.0 20.5 0.1 0 on -site structure Transfer Station 60 1214 120 0 0 0.0 20.4 0.1 0 on -site structure Blake Residence 60 1436 120 0 0 0.0 21.7 0.0 0 off -site structure Scale House 60 1145 120 0 0 0.0 20.8 0.1 0 on -site structure GP-20 60 1332 180 >100 >100 40.1 0.8 28.3 0 Monitoring point, west of cut-off trench GP-21 60 1419 180 >100 >100 31.8 9.3 21.6 0 Monitoring point, east of cut-off trench NOTE: If needed, attach additional data forms to include additional LFG monitoring data locations for the facility. ACTION LEVELS: Methane: >_1.25% by volume (inside structures) AND >5% by volume (at facility boundary) Hydrogen Sulfide: >1 % by volume (inside structures) AND >4% by volume (at facility boundary) Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the p ssibility of a fine and imprisonment. Senior Geologist / S&ME, Inc. SIGNATURE TITLE Revised - March 6, 2017 Table 1 Summary of 2020 & 2022 Methane Gas Readings Moore County Landfill (Permit 63-01) Moore County, North Carolina S&ME Project No. 4358-20-043A Location Scale- house g Point Type • 7 02/17/20 0.0% Maintena Shop • 0.0% Station • 0.0% Blake Crawlspace •V,f, 0.0% GP-9 0.0% r footn tel. 18.7% WUFMl! not installed 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% See footnote#2 0.0% 0.0% 0.0% 0.0% See footnote#1 11.9% Al 28.1% not installed r See footnote#4 not installed NEGEMEM See footnote#4 not installed 04/07/20 0.0% 0.0% 0.0% 0.0% 0.0% 32.2% not installed 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.4% 23.6% 59.9% not installed not installed not installed 09/15/20 0.1% 0.0% 0.0% 0.0% 0.1% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 0.0% 22.5% 0.0% not installed not installed 12/14/20 0.0% 0.0% 0.0% 0.1% 0.1% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.5% 9.6% 61.3% 0.0% not installed not installed 02/24/21 0.0% 0.0% 0.0% NM 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.4% 28.7% 67.9% 0.0% not installed not installed 04/12/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.2% 2.0% 21.8 % 0.0% not installed not installed 09/29/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 1.0% 19.5% 57.5% 0.0% not installed not installed 12/17/21 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 13.8% 27.8% 0.0% 10.1% 57.0% 03/25/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 29.1% 54.7% 0.0% 28.1% 56.4% 06/06/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.0% 4.7% 42.4% 0.0% 30.5% 56.5% 09/26/22 0.0% 0.0% j 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.1% 9.5% 50.8% 0.0% 13.7% 56.1% 12/16/22 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 2.9% 13.8% 56.5% 0.0% 27.4% 51.4% 03/28/23 0.0% 0.0% 0.0% 0.0% 0.0% abandoned 0.0% 0.0% 0.0% abandoned 0.0% abandoned 0.0% abandoned 0.0% 0.0% 0.4% 6.9% 38.7% 0.0% 40.1% 31.8% Notes: Monitoring Point Types: PB = Property Boundary, ONSS = On Site Structure, OFFSS = Off -site Structure Footnote#1 = MW-6 was replace by GP-19 as the property boundary compliance point. MW-6 is approximately 150 feet inside the property boundary and not a compliance point. Footnote#2 = GP-10 was replaced by GP-10R, GP-13 replaced by GP-13R, GP-14 replaced by GP-14R, GP-15 replaced by GP-15R Footnote#3 = Groundwater monitoring well MW-15 converted to gas monitoring point now identified as GP-18, which is a property boundary compliance point. Footnote#4 = Gas monitoring points installed for a cancelled active gas extraction pilot test. A new passive venting pilot test has been proposed. all measurements recorded in percent methane by volume Lower explosive limit of methane gas: 5% Upper explosive limit of methane gas: 15% Data recorded prior to 9/15/20 obtained by Golder not installed = Well not installed at the time of monitoring Yellow highlight cells and values in bold print indicate methane percent by volume greater than or equal to 5% at property boundary monitoring point Orange highlight cells and values in bold print indicate methane percent by volume greater than or equal to 1.25% inside structures. T:\Greensboro-1s80\Projects\2020\4358-2O043A Moore-W Routine LFG&WQMonRoring\h.06-Qu.-N Methane Monitoring 2022-2023\LOG Re dmje Tables-GM1an NPROGRESS.rcIe, 4/11/2023 CERTIFICATION �n OF CALIBRATION dP - No. 66916 Date Of Calibration: 23-Aug-2022 Certificate Number: G506450_9/44689 Issued by: QED Environmental Systems Inc. Non Accredited results: Pressure Transducers inches of water column Transducer Certified (Low) Reading (Low) Certified (High) Reading (High) Accuracy Static 0"1 0" 40" 40.19" 2.0" Differential 0"I 0" 4" 4.03" 0.7" Barometer mbar Reference Instrument Reading 0981 mbar 28.96 "Hg 0981 mbar 128.97 "H As received gas check readings: Methane CH4 Certified Gas % Instrument Reading % 5.0 5.0 15.0 14.8 50.0 , 48.8 Carbon Dioxide CO2 Certified Gas % - Instrument Reading96 5.0 5.3 15.1 15.0 50.0 47.3 0 en 02 Certified Gas % Instrument Reading % 20.9 20.7 As received Gas readings recorded at: 31.9 `C/89.5 7 As received Barometric Pressure recorded at: 22.2 "C/71.9 T As received gas check readings are only recorded if the instrument is received in a working cgndition. Where the instrument is received damaged no reading can be taken. I Date of issue : 24 Aug 2022 Approved By Signatory Kyle Racine Laboratory Inspection The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NISI to the International System of Units (SI). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Cahbre Instance: 114 1GC fast -cc: 114 Page 2 of 2 I LP1115LNANLST-1.1 www.qedenv.com (800) 624-2026 info@gedenv.com QED Environmental Systems Inc. 2355 Bishop Circle West, Dexter, MI 48130 PP CERTIFICATION F OF CALIBRATION VQEff...,, No. 66916 Date Of Calibration: 23-Aug-2022 Certificate Number: G506450_9/44689 Issued by: QED Environmental Systems Inc. Customer., Enviro Equipment Inc 11180 Downs Rd Pineville, NC 28134 USA Description: Landtec Gas Analyzer Model: GEM5000 Serial Number., G506450 Accredited Results: Math:iina 014AI Certified Gas N Instrument Reading % Uncertainty % 5.0 4.9 0.42 15.0 14.9 0.66 50.0 49.2 1.03 Carbon Dioxide(CO2) Certified Gas % instrument Reading % Uncertainty % 5.0 4.9 0.43 15.1 14.9 0.71 50.0 50.0 1.19 oxygen 02 Certified Gas % Instrument Reading % Uncertainty% 20.9 21.0 0.25 Gas cylinders are traceable and details can be provided if requested. CH4, CO2 readings recorded at: 31.9 °C/89.5 "F Barometric Pressure: 0981"Hg/28.96 "Hg 02 readings recorded at: 22.2 °C/71.9 °F Method of Test : The analyzer is calibrated in a temperature controlled chamber using a series of reference gases, in compliance with procedure ISP17. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95%. The uncertainty evaluation has been carried out in accordance with NIST requirements. The calibration results published in this certificate were obtained using equipment capable of producing results that are traceable through NISTto the International System of Units (sl). Certification only applies to results shown. This certificate may not be reproduced other than in full, except with the prior written approval of the issuing laboratory. Cain Insunce:114 IGC Instance: 114 Page I oft l LPOISLNANIST-1.1 www.qedenv.com (800) 624-2026 info@gedenv.com QED Environmental Systems Inc. 2355 Bishop Circle West, Dexter, MI 48130 ENVIRO-EQUIPMENT, [N.C. LANDTEC GEM 5000 Plus CALIBRATION DATA SHEET Serial Number G ��� GI �� Date 3 /7 312 3 Inspector Time/Date Battery Level GO �0 Memory Cleared Pump Faults Gas Alarms: CH4 = 100.0% CO2 = 100.0% V / L G/�,,� f � Zero Transducersy Pump Flow Rate C "I�j 3 Vacuum Oz = 22.0% Tested To 80" H2O V _ Calibration Check (Performed at Room Temperature) Calibration Gas Calibration Gas Concentration Pure N2 l00% Lot Number Expiration y01.3�35-� 0HlZ7 Reading Q- p i� Accuracy* ±2% High CH4 SD /�J _ t/OZ3yS702' 2 66 lie t 2% High CO2 35�6 Low CH4 d LowCO2 �Gz3ys�OZ oyI27 ,J 101Z7 q 0295 1Z5 10127 3 �% ��.a ado t 2% f2% t2% Low 02 y 07-4670k 10127 �-(. G % f 2% High 02 20.9% N/A N/A 1b t 2% Co soerm q0 `257,9 07/214 $0 pry f 10% H2S 10 PPS �6Z442�7� 07i2K 10 f�� ±10% *Accuracy depends upon calibration range; 15%-FS range for CH4 & COZ, 0-5% volume for OZ, 0%-FS for HZS, and 10% of reading for CO. INSPECTOR'S MAINTENANCE NOTES EE[ GEM 2000 Plus Cal Form 01/]2