Loading...
HomeMy WebLinkAbout4101_Guilford_CityHighPoint_Riverdale_MSWLF_Feb23LFG_FID1786962_20230411DocuSign Envelope ID: D5C7150E-569D-4557-86F0-E97BEF1E9439 DENR USE ONLY ❑Paper Report ❑Electronic Data - Email CD (data loaded: Yes / No Doc/Event #: NC DENR I I Environmental Monitoring Division of Waste Management - Solid Waste Reporting Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Instructions: Prepare one form for each individually monitored unit. Please type or print legibly. Attach a notification table with values that attain or exceed NC 2L groundwater standards or NC 2B surface water standards. The notification must include a preliminary analysis of the cause and significance of each value. (e.g. naturally occurring, off -site source, pre-existing condition, etc.). Attach a notification table of any groundwater or surface water values that equal or exceed the reporting limits. Attach a notification table of any methane gas values that attain or exceed explosive gas levels. This includes any structures on or nearby the facility (NCAC 13B .1629 (4)(a)(i). Send the original signed and sealed form, any tables, and Electronic Data Deliverable to: Compliance Unit, NCDENR-DWM, Solid Waste Section, 1646 Mail Service Center, Raleigh, NC 27699-1646. Solid Waste Monitoring Data Submittal Information Name of entity submitting data (laboratory, consultant, facility owner): Smith Gardner, Inc. Contact for questions about data formatting. Include data preparer's name, telephone number and E-mail address: Name: Seth C. Rickerts, PG E-mail: seth@smithgardnerinc.com Phone: (919) 828 - 0577 x135 NC Landfill Rule: Actual sampling dates (e.g., Facility name: Facility Address: Facility Permit # (.0500 or .1600) October 20-24, 2006) High Point Riverdale Closed MSW Riverdale Drive, High Point, NC 41-01 .0500 February 14, 2023 Landfill Environmental Status: (Check all that apply) ❑ Initial/Background Monitoring ❑X Detection Monitoring ❑ Assessment Monitoring Corrective Action of data submitted: (Check all that apply) Groundwater monitoring data from monitoring wells ❑X Groundwater monitoring data from private water supply wells ❑ Leachate monitoring data El water monitoring data Methane gas monitoring data Corrective action data (specify) Other(specify) Notification attached? e No. No groundwater or surface water standards were exceeded. Yes, a notification of values exceeding a groundwater or surface water standard is attached. It includes a list of groundwater and surface water monitoring points, dates, analytical values, NC 2L groundwater standard, NC 2B surface water standard or NC Solid Waste GWPS and preliminary analysis of the cause and significance of any concentration. ❑X Yes, a notification of values exceeding an explosive methane gas limit is attached. It includes the methane monitoring points, dates, sample values and explosive methane gas limits. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. Furthermore, I have attached complete notification of any sampling values meeting or exceeding groundwater standards or explosive gas levels, and a preliminary analysis of the cause and significance of concentrations exceeding groundwater standards. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. Seth C. Rickerts, PG Project Geologist (919) 828 - 0577 x135 Facility Representative Name (Print) Title 4/11/2023 L 5_ C_ Signature "B8'05C9'BEA°E Date 14 N. Boylan Ave, Raleigh, NC 27603 Facility Representative Address F-1370 NC PE Firm License Number (if applicable effective May 1, 2009) Revised 6/2009 (Area Code) Telephone Number Affix NC Licensed/ Professional Geologist Seal a` yi. nl.}{�rrr. rr r E SrAL �i �7S$ 4/1, /2 r DocuSign Envelope ID: D5C7150E-569D-4557-86F0-E97BEF1E9439 This page intentionally left blank. DocuSign Envelope ID: D5C7150E-569D-4557-86F0-E97BEF1E9439 NC Division of Waste Management - Solid Waste Section Landfill Gas Monitoring Data Form Notice: This form and any information attached to it are "Public Records" as defined in NC General Statute 132-1. As such, these documents are available for inspection and examination by any person upon request (NC General Statute 132-6). Facility Name: City of High Point Closed Riverdale Landfill Date of Sampling: 2/14/2023 Name and Position of Sample Collector: Permit Number: 41-01 NC Landfill Rule (.0500 or .1600): .0500 Kyle M. Bonnett - Environmental Technician Type and Serial Number of Gas Meter: GEM 5000, G506472 Date and Time of Field Calibration: 2/14/2023, 1115 Calibration Date of Gas Meter: 01 /2023 Type of Field Calibration Gas (15115 or 35/50): 35/50 Expiration Date of Field Calibration Gas Canister: 10/2023 Pump Rate of Gas Meter: 0.5 LPM Ambient Air Temperature: 63 F Barometric Pressure: 29.23 in Hg General Weather Conditions: Sunny Instructions: Under "Location or LFG Well" identify the monitoring wells or describe the location for other tests (e.g., inside buildings). A drawing showing the location of test must be attached. Report methane readings in both % LEL and % methane by volume. A reading in percent methane by volume can be converted to % LEL as follows: % methane by volume = % LEL/20 Location or LFG Well ID Sample Tube Purge Time Time Pumped (s) Initial ° ZEL Stabilized °,,ZEL df4CH4 by Vohlme %02 %CO2 Notes H2 S ppm 1-1 >60s 1238 >60s 0 0 0.0 16.7 2.6 H2S=2 LFG 3 >60s 1228 >60s 0 0 0.0 20.6 0.5 H2S=2 LFG 4 >60s 1246 >60s 0 0 0.0 20.7 0.0 H2S=2 LFG 5 >60s 1248 >60s 0 0 0.0 19.8 0.4 H2S=3 LFG 6 >60s 1251 >60s 0 0 0.0 20.6 0.1 H2S=3 LFG 7 >60s 1320 >60s 1322 1322 66.1 0.0 23.5 H2S=4 7-1 >60s 1322 >60s 598 598 29.9 3.5 22.3 H2S=3 7-2 >60s 1315 >60s 2 2 0.1 20.3 0.6 H2S=3 7-3 >60s 1313 >60s 6 6 0.3 20.3 0.3 H2S=3 7-4 >60s 1312 >60s 992 992 49.6 1.0 29.5 H2S=3 LFG 8 >60s 1305 >60s 2 2 0.1 20.8 0.1 H2S=3 LFG 8A >60s 1308 >60s 1126 1126 56.3 0.4 22.9 H2S=3 LFG 8B >60s 1310 >60s 4 4 0.2 20.6 0.2 H2S=2 8-1 >60s 1302 >60s 798 798 39.9 0.9 21.1 H2S=3 8-2 >60s 1301 >60s 268 268 13.4 14.3 9.3 H2S=3 8-3 >60s 1259 >60s 1196 1196 59.8 0.6 34.7 H2S=3 8-4 >60s 1327 >60s 612 612 30.6 0.7 120.7 H2S=3 8-5 >60s 1329 >60s 320 320 16.0 3.8 17.0 H2S=3 LFG 9 >60s 1333 >60s 642 642 32.1 3.6 24.3 H2S=3 9-1 >60s 1335 >60s 852 852 42.6 0.8 32.6 H2S=4 LFG 10 >60s 1338 >60s 0 0 0.0 17.7 0.7 H2S=3 Old Maint Bldg >60s 1253 >60s 0 0 0.0 20.8 0.0 H2S=2 Electrical Shop >60s 1254 >60s 0 0 0.0 20.7 0.0 H2S=2 If your facility has more gas monitoring locations than there is room on this form, please attach additional sheets listing the same information as contained on this form. Certification To the best of my knowledge, the information reported and statements made on this data submittal and attachments are true and correct. I am aware that there are significant penalties for making any false statement, representation, or certification including the possibility of a fine and imprisonment. EK DocuSigned by: �& $os.s a;!z 10B56EEF9EA34ED... SIGNATURE Environmental Technician TITLE DocuSign Envelope ID: D5C7150E-569D-4557-86F0-E97BEF1E9439 This page intentionally left blank. DocuSign Envelope ID: D5C7150E-569D-4557-86F0-E97BEF1E9439 Q O M C) M O N X E C 0 I L LM U N 0 H Z_ U Z C O d L U O a_ s■ ;i 4- *N # 1. Y. N 0. LI, Pr Aba i 's - • is - 7•y4 � � 1� � ''r _ • #` F4VOP • •l • •#• -cn LL