HomeMy WebLinkAboutWI-2027_23104_G_UST-23A_20201216_Fail and Pass ResultsTESTING SUMMARY COMPLIANCE TESTING PERFORMED ---- PASS (P) or FAIL (F) or Inconclusive (I) Tank Tightness Test UST-22B / Sensor Function UST-23B / Sump Integrity P/I Line Tightness Test P UST-22B / ATG Cert. UST-23C / Secondary Line Tightness F UST-22A / Overfill Prevention F UST-22C / Sump Visual Inspection UST-23D / Tank Interstitial Tightness P/I UST-22B / Leak Detector Test F UST-23A / Spill Bucket Integrity UST-7A/7B Cathodic Protection Eval OTHER TESTING / SERVICES PERFORMED / MILEAGE Installation of Parts (see page 2) Labor/Repair (One Man) Hours Labor/Repair (Two Man) Hours Vac Truck Hours (Travel Included) PCW Gallons Removed Round Trip Mileage Drop Tube Verification Helium Detection ADDITIONAL COMMENTS/SUMMARY FINDINGS: We were unable to test the premium line and leak detector at this time. We were unable to energize the premium STP pump. There is power going to the pump but we were unable to get it to run. A service company will need to be called to make repairs to the STP pump, and purge product back through the line to get the line and leak detector testing performed. The UST 22A overfill failed on the unleaded, premium, diesel and off road diesel products. The site will need 2-8ft non poppet coaxial with flapper drop tubes with adaptors, and 2-8ft standard with flapper drop tubes installed to correct the issues. The UST 22C visual failed on all containment sumps. All dispenser and STP sumps are ½ full of water. The STP sump lid gaskets are in poor condition on the unleaded, premium, diesel and off road diesel products. The bad gaskets are allowing water to enter the containment sumps. The off road diesel outer steel manway lid does not sit properly along the concrete (pics are available). The UST 23A spill bucket testing failed on the unleaded and diesel products. The buckets failed the 1 hour hydrostatic testing. The unleaded bucket has a breach in the rubber boot in the bottom of the bucket. The diesel bucket is damaged at the top and bottom (pics are available). Repairs will need to be made. SPD dispenser # 4 has a broken shear valve fulcrum arm. The broken fulcrum arm is currently wired in the open position. The fulcrum arm will need to be replaced (pics are available). Customer Name: RD White & Son Inc. Facility Address: 4541 White Street Facility Name: RD White & Son Inc. City/State: Shallotte, NC Facility/Site ID: 00-0-0000035021 Test Date: 12/16/2020 County: Brunswick WO# or PO#: N/A TESTING SUMMARY COMPLIANCE TESTING PERFORMED ---- PASS (P) or FAIL (F) or Inconclusive (I) Tank Tightness Test UST-22B / Sensor Function UST-23B/ Sump Integrity Line Tightness Test P UST-22B / Spill Bucket Visual Gauge UST-23C/ Secondary Line Tightness P UST-22A / Overfill Prevention UST-22C / Sump Visual Inspection UST-23D / Tank Interstitial Tightness UST-22B / Leak Detector Test P UST-23A/ Spill Bucket Integrity UST-7A/7B Cathodic Protection Eval OTHER TESTING/SERVICES PERFORMED / MILEAGE Installation of Parts (see page 2) Labor/Repair (One Man) Hours Labor/Repair (Two Man) Hours Vac Truck Hours (Travel Included) PCW Gallons Removed Round Trip Mileage Drop Tube Verification Helium Detection ADDITIONAL COMMENTS/SUMMARY FINDINGS: Replaced existing OR Diesel drop tube with OPW 71SO 8’ and adaptor to correct previous failure. Replaced existing Premium drop tube with OPW 61SO 8’ with coaxial adaptor to correct previous failure. Re-tested and completed UST-22A, and performed UST-23A testing. Customer Name: RD White & Sons Inc. Facility Address: 4541 White Street Facility Name: RD White & Sons Inc. City/State: Shallotte, NC Facility/Site ID: 00-0-0000035021 Test Date: 1/28/2021 County: Brunswick WO# or PO#: N/A OPW 1 Top Seal Fuel Cap 634TT-7085-EVR 3" Slip On Adapter PV Vent 523SA-1003 Top Seal Vapor Cap 1711T-7085-EVR 3" Thread On Adapter PV Vent 523A-1003 2" Standard Open Vent Cap 23-0033 3 X 4 VR Adaptor (VR Poppett) 1611AV-1620 PV Vent Cap, 2” WC 623V-2203 1 Coaxial Fill Adaptor Aluminum 633TC-8090 3" VR Cap Low Profile 1711LPC-0300 Swivel Adaptor Bronze 61SALP-1020-EVR 2" Slip On Adapter PV Vent 523SA-1002 Swivel Vapor Adaptor Bronze 61VSA-1020-EVR OPW Drop Tubes Morrison 1 Standard Overfill Valve 8' 71SO-400C 4” Fill Brass Adaptor with Lugs 305L-0200AA Standard Overfill Valve 10' 71SO-410C 4” Tank Monitor Cap and Adaptor 305XPA-1200AK Coaxial Poppet Overfill Valve 8’ 61SOP-4002 4" Vapor Recovery Cap 323C--0100AC Coaxial Poppet Overfill Valve 10' 61SOP-4012 Drain Plug Kit EBW 705/71 A1005-505DPEB 1 Coaxial Non-Poppet Valve 8’ 61SOC-4001 Rag Stopper Rag Stopper Coaxial Non-Poppet Valve 10 61SOC-4011 Franklin Fueling/FE Petro EMCO Wheaton Syphon Jet Valve Assembly 400562903 4” Extractor Pipe Cap-Bar Style A0585-003 Syphon Check Valve 400137937 4” Low Profile Orange Vapor Adapter A0099-004LP FE Petro STP-MLD+AG 403169901 Universal Liquid Sump Sensor TSP-ULS ¾ HPFixed Speed STP No Riser STP75-VL2 Model R Check Valve 400988932 Standard Check Valve 400988931 4” Coaxial Fill Adaptor (HC Aluminum) (EBW) 306-300-01 Red Jacket Veeder Root Adjustable Functional Element 323-001-5 DPLLD Without Swift Check Valve 859080-001 Stainless Check valve w/ Spring 144-184-5 WPLLD (wireless) 849490-002 FX1V Mechanical Leak Detector 116-056-5 PLLD With Swift Check Valve 848480-003 FX1DV Mechanical Leak Detector 116-058-5 PLLD Without Swift Check Valve 848480-001 Adjust FunctElemt O-Ring Kit 172-003-5 Packer Discharge Seal (.240) Viton 144-193-1 O-Ring, Packer Manifold, 7 ½ Viton (-443) 072-718-1 Universal Miscellaneous Top Seal Flat Top Cap 731-40 Scotchcast Connector Sealing Pack 3570G-N VR Flat Top Cap 0613VC-30 Brass Fittings 027-274-1 Vent Tubing 085-330-1 Steel Hex Head Cap Screw 026-176-1 Hex Head Packer Manifold Screw 026-205-11 Helium Gas (% of bottle) 4” x 6” Pipe Nipple 406Nipple UST-22A Page 2 Overfill Prevention Equipment Operability Check AUTOMATIC SHUTOFF AND BALL FLOATS UST FACILITY Owner / Operator Name Facility Name Facility ID#: Facility Street Address Facility City County CONTRACTOR/PERSON CONDUCTING INSPECTIONS Company Name Phone Email Address I certify, under penalty of law, that the testing data provided on this form documents the UST system equipment was checked in accordance with the manufacturer’s guidelines and the applicable national industry standards listed in 15A NCAC 2N .0406 and/or 15A NCAC 2N .0900. Print Name of person conducting inspection Signature of person conducting inspection Inspection Date Overfill Equipment Check Tank # Tank # Tank # Tank # Tank # Product: Tank chart volume (gallons): Tank diameter (inches): Tank Type: FRP Steel FRP Steel FRP Steel FRP Steel FRP Steel If FRP Compartment tank, select: Base End Base End Base End Base End Base End Overfill device manufacturer/model Flapper Valve/Auto Shut Off A “No” answer to any items below or ball float length not determined and flapper/auto shut-off greater than 90% indicates an operability check failure. Drop tube removed from tank? Yes No Yes No Yes No Yes No Yes No Drop tube and float mechanism are free of debris? Yes No Yes No Yes No Yes No Yes No Float moves freely without binding and poppet moves into flow path? Yes No Yes No Yes No Yes No Yes No Bypass valve in the drop tube is open and free of blockage (if present)? Yes No Not Present Yes No Not Present Yes No Not Present Yes No Not Present Yes No Not Present Current length from tank top to final shutoff point (inches) FSP Percent tank volume when final shutoff occurs (%) If tank has a ball float, is the flapper installed lower in tank than the ball float? (If present, complete ball float length and percent set point below) Yes No Length not Determined Not Present Yes No Length not Determined Not Present Yes No Length not Determined Not Present Yes No Length not Determined Not Present Yes No Length not Determined Not Present Ball Float Valve A “No” answer to any items below indicates an operability check failure. Tank top fittings are vapor tight? Yes No Yes No Yes No Yes No Yes No Ball Float removed from tank? Yes No Yes No Yes No Yes No Yes No Cage intact & ball in good condition, ball moves freely & seats firmly? Yes No Yes No Yes No Yes No Yes No Vent hole in pipe is open and near top of tank? Yes No Yes No Yes No Yes No Yes No Current length from tank top to ball float set point (inches) BFSP 30-minute flow restrictor installed (if ball float set at more than 90%) (Provide documentation such as pictures/hole diameter) Yes N/A Yes N/A Yes N/A Yes N/A Yes N/A Percent tank volume when flow restriction occurs (%) Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Inspection result NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY, DIVISION OF WASTE MANAGEMENT, UST SECTION 1646 MAIL SERVICE CENTER, RALEIGH, NC 27699-1646 PHONE (919) 707-8171 FAX (919) 715-1117 http://www.wastenotnc.org 5/2020 00-0-0000035021RD White & Sons Inc. 4541 White Street Shallotte Brunswick RD White & Sons Inc. PetroTest, Inc.(919)902-3794 PetroTest@PetroTest.net Stephen G. Pope 01/28/2021 2 134 Unleaded Premium Diesel OffRoadDiesel 10,171 6,027 10,171 6,027 94.5 94.5 94.5 94.5 OPW 61S0C OPW 61SOC OPW 71SO OPW 71SO ■■■■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 9.5 9.5 9.5 9.5 95.0 95.0 95.0 95.0 ■■■■ ■■■■ UST-22B Annual Leak Detection Equipment Operability Check NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY, DIVISION OF WASTE MANAGEMENT, UST SECTION 1646 MAIL SERVICE CENTER, RALEIGH, NC 27699-1646 PHONE (919) 707-8171 FAX (919) 715-1117 http://www.wastenotnc.org/12/2020 Page 2 (Automatic Tank Gauge / Spill Bucket Visual Gauge) Inspect the leak detection equipment in accordance with manufacturer guidelines and PEI RP 1200, “Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection, and Secondary Containment Equipment at UST Facilities”. Results must be maintained for at least one year at the UST site or the tank owner or operator's place of business and be readily available for inspection. UST FACILITY Owner / Operator Name RD White & Sons Facility ID 00-0-0000035021 Facility Name RD White & Sons Facility Street Address 4541 White Street Facility City Shallotte County Brunswick CONTRACTOR/PERSON CONDUCTING INSPECTIONS Company Name PetroTest, Inc. Phone (919) 902 3794 Email address PeroTest@PetroTest.net I certify, under penalty of law, that the testing data provided on this form documents the UST system equipment was checked in accordance with the manufacturer's guidelines and the applicable national industry standards listed in 15A NCAC 2N .407/.0501. Print Name of person conducting inspection Stephen G. Pope Signature of person conducting inspection Inspection Date 01/28/2021 Tank Volume (gallons):10,171 10,171 Tank Diameter (inches):94.5 94.5 Product:Unleaded Diesel Automatic Tank Gauge (ATG)N/A Note: If the facility is using the ATG to obtain data for SIR then the ATG operability check must be completed. ATG Brand and Model 1. Using tank stick measure fuel level. Stick value agrees with Fuel float level displayed on console?Yes No Yes No Yes No Yes No 2. Using tank stick measure water level. Stick value agrees with Water float level displayed on console?Yes No Yes No Yes No Yes No 3. After removing the ATG probe from the tank, has it been inspected and any damaged or missing parts replaced?Yes No Yes No Yes No Yes No Magnetostrictive Probes 4. Float moves freely on the stem without binding?Yes No Yes No Yes No Yes No 5. Inch level from bottom of stem when 90% alarm is triggered. 6. Inch level at which the overfill alarm activates corresponds with value programmed in the gauge?Yes No Yes No Yes No Yes No 7. Inch level from bottom when the water float first triggers an alarm. 8. Inch level at which the water float alarm activates corresponds with value programmed in gauge?Yes No Yes No Yes No Yes No 9. Alarm reports attached?NoYes NoYes NoYes NoYes If any answers in Lines 1, 2, or 3 (all ATGs); 4, 6, 8 or 9 (for Mag Probes); 10 or 11 (for Cap Probes) are “No”, the system has failed the test. Test Results Pass Fail Pass Fail Pass Fail Pass Fail Capacitance Probes 10. Initiated diagnostic check of probes from console?Yes No Yes No Yes No Yes No 11. Diagnostic check does not show any open or shorted segments in measurement section of probe? (Attach diagnostic report to form) NoYes NoYes NoYes NoYes Comments and explanation of failing results and other problems noted during inspection: Spill Bucket Interstice Visual Gauge N/A Gauge manufacturer OPW OPW Gauge removed and visually inspected, and no damage noted?Yes No Yes No Yes No Yes No O-ring/seals on entry fitting of gauge are present and not damaged?Yes No Yes No Yes No Yes No Float mechanism moves freely up and down?Yes No Yes No Yes No Yes No Indicator arrow rotates when float moved up and down (Franklin Fueling and OPW) or Indicator shows red, “TEST”, when float in up position and green, “Ok” when float in down position (Emco Wheaton)? Yes No Yes No Yes No Yes No Test Results Pass Fail Pass Fail Pass Fail Pass Fail Any “No” answer indicates the equipment fails the test. UST-6D/23A Triennial UST Spill Bucket Integrity Testing NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY, DIVISION OF WASTE MANAGEMENT, UST SECTION 1646 MAIL SERVICE CENTER, RALEIGH, NC 27699-1646 PHONE (919) 707-8171 FAX (919) 715-1117 http://www.wastenotnc.org/5/2020 Page 1 (Hydrostatic/Vacuum Test) • If any periodic test fails, a suspected release report must be submitted on a UST-17A form, UST Suspected Release 24 Hour Notice. The suspected release must be investigated, in accordance with 15A NCAC 2N .0603, and defective equipment repaired or replaced in accordance with 15A NCAC 2N .0404/.0900. Results of the investigation must be submitted on a UST-17B form, UST Suspected Release 7 Day Notice. • The primary containment and interstitial space of the spill bucket shall be tested in accordance with the manufacturer's written guidelines, PEI/RP100 “Recommended Practices for Installation of Underground Liquid Storage Systems” and/or PEI/RP1200 “Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities.” • The primary and secondary walls are both considered to be tested at the same time if vacuum is used to test the interstice. UST FACILITY Owner / Operator Name Facility IDFacility Name Facility Street Address Facility City County TESTING CONTRACTOR INFORMATION Company Name Phone Email address I certify, under penalty of law, that the testing data provided on this form documents the UST system equipment was checked in accordance with the manufacturer's guidelines and the applicable national industry standards listed in 15A NCAC 2N .407/.0501 and/or 15A NCAC 2N .0900. Print Name of person conducting inspection Signature of person conducting inspection Test Date Identify Spill Bucket (By Tank Number, Stored Product, etc.)Tank #Tank #Tank #Tank #Tank # Tank Size Product Indicate units for all measurements Bucket Manufacturer/Model Bucket Depth Construction SW DW SW DW SW DW SW DW SW DW Bucket Installation Type Direct Bury Direct Bury w/Liner Containment sump Direct Bury Direct Bury w/Liner Containment sump Direct Bury Direct Bury w/Liner Containment sump Direct Bury Direct Bury w/Liner Containment sump Direct Bury Direct Bury w/Liner Containment sump Test Type Hydrostatic Vacuum Hydrostatic Vacuum Hydrostatic Vacuum Hydrostatic Vacuum Hydrostatic Vacuum Liquid and debris removed from spill bucket?Yes No Yes No Yes No Yes No Yes No Visual inspection (No cracks, loose parts or separation of the bucket from the fill pipe.)Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Tank riser cap included in test?Yes No N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A Drain valve included in test?Yes No N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A Wait time between applying vacuum/water and start of test Primary Section Test Hydrostatic: Water level must be within 1.5 inches of top of bucket Vacuum: Apply vacuum of 30 inches WC Begin End Test Time Begin End Reading Secondary Interstice Test Vacuum: Apply vacuum of 15 inches WC Begin End Test Time Begin End Reading Pass/fail criteria: Must pass visual inspection. Hydrostatic: Water level drop of less than 1/8 inch in 1 hour; Vacuum single-walled only: Maintain at least 26 inches water column for 1 minute; Vacuum double-walled: Maintain at least 12 inches water column for 1 minute Test Results Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) Date next Spill Bucket integrity test due (required every 3 years) RD White & Sons Inc.00-0-0000035021RD White & Sons 4541 White Street Shallotte Brunswick PetroTest, Inc. (919)902-3794 PetroTest@PetroTest.net Stephen G. Pope 01/28/2021 2134 10,171 6,027 10,171 6,027 Unleaded Premium Diesel Off Road Diesel OPW 1C-3112P Pemeco 111-L OPW 1C-3112P Pemeco 111L 12.0"12.0" 12.0"12.0" 30 Seconds 15 Minutes 30 Seconds 15 Minutes 12:15pm 1:15pm 12:15pm 1:15pm 12.0" 12.0"12.0" 12.0" 11:51am 11:56am 11:51am 11:56am -15" -15"-15" -15" 01/28/2024